Sample records for high initial discharge

  1. High-current discharge channel contraction in high density gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutberg, Ph. G.; Bogomaz, A. A.; Pinchuk, M. E.

    Research results for discharges at current amplitudes of 0.5-1.6 MA and current rise rate of {approx}10{sup 10} A/s are presented. The discharge is performed in the hydrogen environment at the initial pressure of 5-35 MPa. Initiation is implemented by a wire explosion. The time length of the first half-period of the discharge current is 70-150 {mu}s. Under such conditions, discharge channel contraction is observed; the contraction is followed by soft x-ray radiation. The phenomena are discussed, which are determined by high density of the gas surrounding the discharge channel. These phenomena are increase of the current critical value, where themore » channel contraction begins and growth of temperature in the axis region of the channel, where the initial density of the gas increases.« less

  2. Sessile multidroplets and salt droplets under high tangential electric fields

    PubMed Central

    Xie, Guoxin; He, Feng; Liu, Xiang; Si, Lina; Guo, Dan

    2016-01-01

    Understanding the interaction behaviors between sessile droplets under imposed high voltages is very important in many practical situations, e.g., microfluidic devices and the degradation/aging problems of outdoor high-power applications. In the present work, the droplet coalescence, the discharge activity and the surface thermal distribution response between sessile multidroplets and chloride salt droplets under high tangential electric fields have been investigated with infrared thermography, high-speed photography and pulse current measurement. Obvious polarity effects on the discharge path direction and the temperature change in the droplets in the initial stage after discharge initiation were observed due to the anodic dissolution of metal ions from the electrode. In the case of sessile aligned multidroplets, the discharge path direction could affect the location of initial droplet coalescence. The smaller unmerged droplet would be drained into the merged large droplet as a result from the pressure difference inside the droplets rather than the asymmetric temperature change due to discharge. The discharge inception voltages and the temperature variations for two salt droplets closely correlated with the ionization degree of the salt, as well as the interfacial electrochemical reactions near the electrodes. Mechanisms of these observed phenomena were discussed. PMID:27121926

  3. 77 FR 18963 - Energy Conservation Program: Public Meeting and Availability of the Framework Document for High...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-29

    ... the Framework Document for High-Intensity Discharge Lamps AGENCY: Office of Energy Efficiency and... availability of framework document for high-intensity discharge (HID) lamps, initiating the rulemaking and data... Availability of Framework Document Regarding Energy Conservation Standards for High-Intensity Discharge (HID...

  4. Initiation of long, free-standing z discharges by CO2 laser gas heating

    NASA Astrophysics Data System (ADS)

    Niemann, C.; Tauschwitz, A.; Penache, D.; Neff, S.; Knobloch, R.; Birkner, R.; Presura, R.; Hoffmann, D. H. H.; Yu, S. S.; Sharp, W. M.

    2002-01-01

    High current discharge channels can neutralize both current and space charge of very intense ion beams. Therefore, they are considered an interesting solution for final focus and beam transport in a heavy ion beam fusion reactor. At the Gesellschaft für Schwerionenforschung accelerator facility, 50 cm long, free-standing discharge channels were created in a 60 cm diameter metallic chamber. Discharges with currents of 45 kA in 2 to 25 mbar ammonia (NH3) gas are initiated by a CO2 laser pulse along the channel axis before the capacitor bank is triggered. Resonant absorption of the laser, tuned to the v2 vibration of the ammonia molecule, causes strong gas heating. Subsequent expansion and rarefaction of the gas prepare the conditions for a stable discharge to fulfill the requirements for ion beam transport. The influence of an electric prepulse on the high current discharge was investigated. This article describes the laser-gas interaction and the discharge initiation mechanism. We found that channels are magnetohydrodynamic stable up to currents of 45 kA, measured by fast shutter and streak imaging techniques. The rarefaction of the laser heated gas is studied by means of a one-dimensional Lagrangian fluid code (CYCLOPS) and is identified as the dominant initiation mechanism of the discharge.

  5. The Subiculum: A Potential Site of Ictogenesis in a Neonatal Seizure Model

    PubMed Central

    Wang, Xin-Xin; Li, Yong-Hua; Gong, Hai-Qing; Liang, Pei-Ji; Zhang, Pu-Ming; Lu, Qin-Chi

    2017-01-01

    Studies have reported that the subiculum is one origin of interictal-like discharges in adult patients with temporal lobe epilepsy; however, whether the subiculum represents a site of ictogenesis for neonatal seizures remains unclear. In this study, multi-electrode recording techniques were used to record epileptiform discharges induced by low-Mg2+ or high-K+ artificial cerebrospinal fluid in neonatal mouse hippocampal slices, and the spatiotemporal dynamics of the epileptiform discharges were analyzed. The Na+–K+–2Cl− cotransporter 1 (NKCC1) blocker, bumetanide, was applied to test its effect upon epileptiform discharges in low-Mg2+ model. The effect of N-methyl-d-aspartate receptors (NMDARs) antagonist, d-AP5, upon the epileptiform discharges in high-K+ model was examined. We found that the neonatal subiculum not only relayed epileptiform discharges emanating from the hippocampus proper (HP) but also initiated epileptiform discharges (interictal- and ictal-like discharges) independently. The latency to onset of the first epileptiform discharge initiated in the subiculum was similar to that initiated in the HP. Bumetanide efficiently blocked seizures in the neonatal HP, but was less effectively in suppressing seizures initiated in the subiculum. In high-K+ model, d-AP5 was more effective in blocking seizures initiated in the subiculum than that initiated in the HP. Furthermore, Western blotting analysis showed that NKCC1 expression was lower in the subiculum than that in the HP, whereas the expression of NMDAR subunits, NR2A and NR2B, was higher in the subiculum than that in the HP. Our results revealed that the subiculum was a potential site of ictogenesis in neonatal seizures and possessed similar seizure susceptibility to the HP. GABAergic excitation resulting from NKCC1 may play a less dominant role during ictogenesis in the subiculum than that in the HP. The subicular ictogenesis may be related to the glutamatergic excitation mediated by NMDARs. PMID:28473802

  6. Glow plasma trigger for electron cyclotron resonance ion sources.

    PubMed

    Vodopianov, A V; Golubev, S V; Izotov, I V; Nikolaev, A G; Oks, E M; Savkin, K P; Yushkov, G Yu

    2010-02-01

    Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 micros and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10(12) cm(-3), required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T(e) approximately = 20 eV.

  7. Modification of surface layers of copper under the action of the volumetric discharge initiated by an avalanche electron beam in nitrogen and CO2 at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Shulepov, M. A.; Akhmadeev, Yu. Kh.; Tarasenko, V. F.; Kolubaeva, Yu. A.; Krysina, O. V.; Kostyrya, I. D.

    2011-05-01

    The results of experimental investigations of the action of the volumetric discharge initiated by an avalanche electron beam on the surface of copper specimens are presented. The volumetric (diffuse) discharge in nitrogen and CO2 at atmospheric pressure was initiated by applying high voltage pulses of nanosecond duration to a tubular foil cathode. It has been found that the treatment of a copper surface by this type of discharge increases the hardness of the surface layer due to oxidation.

  8. Nanosecond repetitively pulsed discharges in air at atmospheric pressure—the spark regime

    NASA Astrophysics Data System (ADS)

    Pai, David Z.; Lacoste, Deanna A.; Laux, Christophe O.

    2010-12-01

    Nanosecond repetitively pulsed (NRP) spark discharges have been studied in atmospheric pressure air preheated to 1000 K. Measurements of spark initiation and stability, plasma dynamics, gas temperature and current-voltage characteristics of the spark regime are presented. Using 10 ns pulses applied repetitively at 30 kHz, we find that 2-400 pulses are required to initiate the spark, depending on the applied voltage. Furthermore, about 30-50 pulses are required for the spark discharge to reach steady state, following initiation. Based on space- and time-resolved optical emission spectroscopy, the spark discharge in steady state is found to ignite homogeneously in the discharge gap, without evidence of an initial streamer. Using measured emission from the N2 (C-B) 0-0 band, it is found that the gas temperature rises by several thousand Kelvin in the span of about 30 ns following the application of the high-voltage pulse. Current-voltage measurements show that up to 20-40 A of conduction current is generated, which corresponds to an electron number density of up to 1015 cm-3 towards the end of the high-voltage pulse. The discharge dynamics, gas temperature and electron number density are consistent with a streamer-less spark that develops homogeneously through avalanche ionization in volume. This occurs because the pre-ionization electron number density of about 1011 cm-3 produced by the high frequency train of pulses is above the critical density for streamer-less discharge development, which is shown to be about 108 cm-3.

  9. Lightning Mapping Observations of Volume-Filling Small Discharges in Thunderstorms

    NASA Astrophysics Data System (ADS)

    Rison, W.; Krehbiel, P. R.; Thomas, R. J.; Rodeheffer, D.

    2013-12-01

    Lightning is usually considered to be a large-scale electrical discharge in the atmosphere. For example, the American Meteorological Society's Glossary of Meteorology defines lightning as "a transient, high-current electric discharge with pathlengths measured in kilometers" (http://glossary.ametsoc.org/wiki/Lightning). There have been several reported examples of short-duration discharges in thunderstorms, which have a duration of a few microseconds to less than a millisecond, and have a small spatial extent These short-duration discharges were located at high altitudes (> 14 km), altitudes consistent with being located between the upper positive charge and the negative screening layer. At these altitudes, the electric field needed to initiate an electrical discharge is much lower than it is at the altitudes of initiation for IC (~8 km) or CG (~5 km) flashes. We have recently reported on short-duration "precursor" discharges with durations of a few microseconds to a few milliseconds, which occur in the high-fields between the mid-level negative and upper positive charge regions. These "precursor" discharges are discrete in both time and space, being separated in time by hundreds of milliseconds to several seconds, and localized in space, usually very close to the initiation location of a subsequent IC discharge. We have recently observed nearly continuous, volume filling short-duration discharges in several thunderstorms. These discharges have durations of much less than a millisecond, spatial extents of less than a few hundred meters, and occur randomly in the volume between the mid-level negative and upper positive charge regions. During an active period, these discharges occur every few milliseconds. The rates of these discharges decreases dramatically to a few per second following an IC discharge, then increases to several hundred per second until the next discharge. In a storm just off the Florida coast, one cell was producing a large number of these small discharges, while a contemporaneous cell a few kilometers west produced no detectable small discharges. Short-duration discharges occur at altitudes between 10 km and 14 km in the intervals between lightning discharges. The rates of short-duration discharges decreases dramatically after a lightning discharge.

  10. Observations of narrow bipolar events reveal how lightning is initiated in thunderstorms

    PubMed Central

    Rison, William; Krehbiel, Paul R.; Stock, Michael G.; Edens, Harald E.; Shao, Xuan-Min; Thomas, Ronald J.; Stanley, Mark A.; Zhang, Yang

    2016-01-01

    A long-standing but fundamental question in lightning studies concerns how lightning is initiated inside storms, given the absence of physical conductors. The issue has revolved around the question of whether the discharges are initiated solely by conventional dielectric breakdown or involve relativistic runaway electron processes. Here we report observations of a relatively unknown type of discharge, called fast positive breakdown, that is the cause of high-power discharges known as narrow bipolar events. The breakdown is found to have a wide range of strengths and is the initiating event of numerous lightning discharges. It appears to be purely dielectric in nature and to consist of a system of positive streamers in a locally intense electric field region. It initiates negative breakdown at the starting location of the streamers, which leads to the ensuing flash. The observations show that many or possibly all lightning flashes are initiated by fast positive breakdown. PMID:26876654

  11. Observations of narrow bipolar events reveal how lightning is initiated in thunderstorms.

    PubMed

    Rison, William; Krehbiel, Paul R; Stock, Michael G; Edens, Harald E; Shao, Xuan-Min; Thomas, Ronald J; Stanley, Mark A; Zhang, Yang

    2016-02-15

    A long-standing but fundamental question in lightning studies concerns how lightning is initiated inside storms, given the absence of physical conductors. The issue has revolved around the question of whether the discharges are initiated solely by conventional dielectric breakdown or involve relativistic runaway electron processes. Here we report observations of a relatively unknown type of discharge, called fast positive breakdown, that is the cause of high-power discharges known as narrow bipolar events. The breakdown is found to have a wide range of strengths and is the initiating event of numerous lightning discharges. It appears to be purely dielectric in nature and to consist of a system of positive streamers in a locally intense electric field region. It initiates negative breakdown at the starting location of the streamers, which leads to the ensuing flash. The observations show that many or possibly all lightning flashes are initiated by fast positive breakdown.

  12. Rationale and design of TRANSITION: a randomized trial of pre-discharge vs. post-discharge initiation of sacubitril/valsartan.

    PubMed

    Pascual-Figal, Domingo; Wachter, Rolf; Senni, Michele; Belohlavek, Jan; Noè, Adele; Carr, David; Butylin, Dmytro

    2018-04-01

    The prognosis after hospitalization for acute decompensated heart failure (ADHF) remains poor, especially <30 days post-discharge. Evidence-based medications with prognostic impact administered at discharge improve survival and hospital readmission, but robust studies comparing pre-discharge with post-discharge initiation are rare. The PARADIGM-HF trial established sacubitril/valsartan as a new evidence-based therapy in patients with heart failure (HF) and reduced left ventricular ejection fraction (<40%) (rEF). In common with other landmark studies, it enrolled patients who were ambulatory at the time of inclusion. In addition, there is also still limited knowledge of initiation and up-titration of sacubitril/valsartan in ACEi/ARB- naïve patients and in de novo HF with rEF patients. TRANSITION is a multicentre, open-label study in which ~1000 adults hospitalized for ADHF with rEF are randomized to start sacubitril/valsartan in a pre-discharge arm (initiated ≥24 h after haemodynamic stabilization) or a post-discharge arm (initiated within Days 1-14 after discharge). The protocol allows investigators to select the appropriate starting dose and dose adjustments according to clinical circumstances. Over a 10 week treatment period, the primary and secondary objectives assess the feasibility and safety of starting sacubitril/valsartan in-hospital, early after haemodynamic stabilization. Exploratory objectives also include assessment of HF signs and symptoms, readmissions, N-terminal pro-B-type natriuretic peptide and high-sensitivity troponin T levels, and health resource utilization parameters. TRANSITION will provide new evidence about initiating sacubitril/valsartan following hospitalization for ADHF, occurring either as de novo ADHF or as deterioration of chronic HF, and in patients with or without prior ACEI/ARB therapy. The results of TRANSITION will thus be highly relevant to the management of patients hospitalized for ADHF with rEF. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  13. Influence of shock waves from plasma actuators on transonic and supersonic airflow

    NASA Astrophysics Data System (ADS)

    Mursenkova, I. V.; Znamenskaya, I. A.; Lutsky, A. E.

    2018-03-01

    This paper presents experimental and numerical investigations of high-current sliding surface discharges of nanosecond duration and their effect on high-speed flow as plasma actuators in a shock tube. This study deals with the effectiveness of a sliding surface discharge at low and medium air pressure. Results cover the electrical characteristics of the discharge and optical visualization of the discharge and high-speed post-discharge flow. A sliding surface discharge is first studied in quiescent air conditions and then in high-speed flow, being initiated in the boundary layer at a transverse flow velocity of 50-950 m s-1 behind a flat shock wave in air of density 0.04-0.45 kg m-3. The discharge is powered by a pulse voltage of 25-30 kV and the electric current is ~0.5 kA. Shadow imaging and particle image velocimetry (PIV) are used to measure the flow field parameters after the pulse surface discharge. Shadow imaging reveals shock waves originating from the channels of the discharge configurations. PIV is used to measure the velocity field resulting from the discharge in quiescent air and to determine the homogeneity of energy release along the sliding discharge channel. Semicylindrical shock waves from the channels of the sliding discharge have an initial velocity of more than 600 m s-1. The shock-wave configuration floats in the flow along the streamlined surface. Numerical simulation based on the equations of hydrodynamics matched with the experiment showed that 25%-50% of the discharge energy is instantly transformed into heat energy in a high-speed airflow, leading to the formation of shock waves. This energy is comparable to the flow enthalpy and can result in significant modification of the boundary layer and the entire flow.

  14. Investigation of heavy current discharges with high initial gas density

    NASA Astrophysics Data System (ADS)

    Budin, A.; Bogomaz, A.; Kolikov, V.; Kuprin, A.; Leontiev, V.; Rutberg, Ph.; Shirokov, N.

    1996-05-01

    Piezoelectric pressure transducers, with noise immunity and time resolution of 0,5 μs were used to measure pulse pressures of 430 MPa along the axis of an electrical discharge channel. Initial concentration of He was 2,7ṡ1021cm-3, dI/dt=6ṡ1011 A/s, and Imax=560 kA. Shock waves with amplitudes exceeding the pressure along the axis, were detected by a pressure transducer on the wall of the discharge chamber. Typical shock velocities were 2ṡ4 km/s. Average pressure measurements along the discharge axis at different radii were used to estimate the current density distribution along the canal radius. The presence of the shock waves, promoting the additional hydrogen heating in the discharge chamber, has been registered during the discharge in hydrogen for Imax˜1 MA and an initial concentration of 1021cm-3.

  15. Plasma Assisted Ignition and Combustion at Low Initial Gas Temperatures: Development of Kinetic Mechanism

    DTIC Science & Technology

    2016-10-05

    describes physics of a nanosecond surface dielectric barrier discharge (SDBD) at ambient gas temperature and high pressures (1-6 bar) in air. Details about...the ignition by a nanosecond discharge. Chapter 7 presents the high pressure high temperature reactor built recently at Laboratory for Plasma Physics ...livelink.ebs.afrl.af.mil/livelink/llisapi.dll Laboratory for Physics of Plasma, Ecole Polytechnique Plasma Assisted Ignition and Combustion at Low Initial Gas

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rison, William; Krehbiel, Paul R.; Stock, Michael G.

    A long-standing but fundamental question in lightning studies concerns how lightning is initiated inside storms, given the absence of physical conductors. The issue has revolved around the question of whether the discharges are initiated solely by conventional dielectric breakdown or involve relativistic runaway electron processes. Here we report observations of a relatively unknown type of discharge, called fast positive breakdown, that is the cause of high-power discharges known as narrow bipolar events. We find that the breakdown has a wide range of strengths and is the initiating event of numerous lightning discharges. It appears to be purely dielectric in naturemore » and to consist of a system of positive streamers in a locally intense electric field region. It initiates negative breakdown at the starting location of the streamers, which leads to the ensuing flash. The observations show that many or possibly all lightning flashes are initiated by fast positive breakdown.« less

  17. Effect of Risk Acceptance for Bundled Care Payments on Clinical Outcomes in a High-Volume Total Joint Arthroplasty Practice After Implementation of a Standardized Clinical Pathway.

    PubMed

    Kee, James R; Edwards, Paul K; Barnes, Charles L

    2017-08-01

    The Bundled Payments for Care Improvement (BPCI) initiative and the Arkansas Payment Improvement (API) initiative seek to incentivize reduced costs and improved outcomes compared with the previous fee-for-service model. Before participation, our practice initiated a standardized clinical pathway (CP) to reduce length of stay (LOS), readmissions, and discharge to postacute care facilities. This practice implemented a standardized CP focused on patient education, managing patient expectations, and maximizing cost outcomes. We retrospectively reviewed all primary total joint arthroplasty patients during the initial 2-year "at risk" period for both BPCI and API and determined discharge disposition, LOS, and readmission rate. During the "at risk" period, the average LOS decreased in our total joint arthroplasty patients and our patients discharged home >94%. Patients within the BPCI group had a decreased discharge to home and decreased readmission rates after total hip arthroplasty, but also tended to be older than both API and nonbundled payment patients. While participating in the BPCI and API, continued use of a standardized CP in a high-performing, high-volume total joint practice resulted in maintenance of a low-average LOS. In addition, BPCI patients had similar outcomes after total knee arthroplasty, but had decreased rates of discharge to home and readmission after total hip arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Relationship of initial hematocrit level to discharge destination and resource utilization after ischemic stroke: a pilot study.

    PubMed

    Diamond, Paul T; Gale, Shawn D; Evans, Brent A

    2003-07-01

    To examine the association between initial hematocrit level at the time of ischemic stroke, discharge destination, and resource utilization. Case series. University hospital. A total of 1012 consecutive patients with ischemic stroke admitted to a university health system between August 3, 1995, and June 24, 1999. Not applicable. Length of stay, hospital cost, and discharge disposition. Of 1012 patients presenting with ischemic stroke, 58% were discharged home, 10% were discharged home with home care services, 15% were discharged to a rehabilitation hospital, 11% were discharged to a skilled or intermediate care facility, and 6% died. After adjusting for age, sex, race, and comorbidities, a significant association (P=.009) existed between discharge outcome and initial hematocrit level. The probability of achieving an equivalent or less favorable outcome increased at both high and low hematocrit levels, with a minimum probability at a hematocrit level of approximately 45%. An association exists between hematocrit level at the time of ischemic stroke and discharge outcome. Midrange hematocrit levels appear to be associated with discharge to home rather than to an inpatient rehabilitation unit or to a nursing facility. Further study is indicated to examine the relationship among hematocrit level, stroke severity, and outcome.

  19. Fast repetition rate (FRR) flasher

    DOEpatents

    Kolber, Zbigniew; Falkowski, Paul

    1997-02-11

    A fast repetition rate (FRR) flasher suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between Successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz.

  20. Observations of narrow bipolar events reveal how lightning is initiated in thunderstorms

    DOE PAGES

    Rison, William; Krehbiel, Paul R.; Stock, Michael G.; ...

    2016-02-15

    A long-standing but fundamental question in lightning studies concerns how lightning is initiated inside storms, given the absence of physical conductors. The issue has revolved around the question of whether the discharges are initiated solely by conventional dielectric breakdown or involve relativistic runaway electron processes. Here we report observations of a relatively unknown type of discharge, called fast positive breakdown, that is the cause of high-power discharges known as narrow bipolar events. We find that the breakdown has a wide range of strengths and is the initiating event of numerous lightning discharges. It appears to be purely dielectric in naturemore » and to consist of a system of positive streamers in a locally intense electric field region. It initiates negative breakdown at the starting location of the streamers, which leads to the ensuing flash. The observations show that many or possibly all lightning flashes are initiated by fast positive breakdown.« less

  1. Radiative Characteristics of the Pulse-Periodic Discharge Plasma Initiated by Runaway Electrons

    NASA Astrophysics Data System (ADS)

    Lomaev, M. I.; Beloplotov, D. V.; Tarasenko, V. F.; Sorokin, D. A.

    2016-07-01

    Results of experimental investigations of amplitude-temporal and spectral characteristics of radiation of a pulse-periodic discharge plasma initiated in nitrogen by runaway electrons are presented. The discharge was initiated by high-voltage nanosecond voltage pulses with repetition frequency of 60 Hz in a sharply inhomogeneous electric field in a gap between the conic potential cathode and the planar grounded aluminum anode. It is established that intensive lines of Al I atoms and Al II atomic ions, lines of N I atoms and N II ions, bands of the first (1+) and second positive (2+) nitrogen systems, as well as bands of cyanogen CN are observed in the emission spectrum of the discharge plasma under the given excitation conditions.

  2. Puncture discharges in surface dielectrics as contaminant sources in spacecraft environments

    NASA Technical Reports Server (NTRS)

    Yadlowsky, E. J.; Hazelton, R. C.; Churchill, R. J.

    1978-01-01

    Spacecraft in geosynchronous orbits are known to become charged to large negative potentials during the local midnight region of the satellite orbit. Such discharges have been studied by the electron beam irradiation of dielectric samples in a vacuum environment. In addition to static measurements and photographic examination of the puncture discharges in Teflon samples, the transient characteristics of the electrical discharges are determined from oscillographs of voltage and current and by charged particle measurements employing a biased Faraday cup and a retarding potential analyzer. Using these latter techniques, studies of angular and energy distributions of charged particles have indicated an initial burst of high energy electrons (5 x 10 to the 13th power per discharge at energies greater than 300 eV) followed by a less intense burst of lower energy negative particles. Positive ions are emitted from the discharge site in an initial high velocity burst followed by a lower velocity burst tentatively identified as carbon.

  3. Fast repetition rate (FRR) flasher

    DOEpatents

    Kolber, Z.; Falkowski, P.

    1997-02-11

    A fast repetition rate (FRR) flasher is described suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz. 14 figs.

  4. Deflagration-to-Detonation Transition Control by Nanosecond Gas Discharges

    DTIC Science & Technology

    2008-04-07

    Report 3. DATES COVERED (From – To) 1 April 2007 - 18 August 09 4. TITLE AND SUBTITLE Deflagration-To- Detonation Transition Control By Nanosecond...SUPPLEMENTARY NOTES 14. ABSTRACT During the current project, an extensive experimental study of detonation initiation by high{voltage...nanosecond gas discharges has been performed in a smooth detonation tube with different discharge chambers and various discharge cell numbers. The chambers

  5. Application of surface electrical discharges to the study of lightning strikes on aircraft

    NASA Technical Reports Server (NTRS)

    Boulay, J. L.; Larigaldie, S.

    1991-01-01

    Considered here is the characterization of surface discharges which provide a facility complementary to that of artificially triggered lightning. General characteristics of a simplified surface discharge, including current waveforms and the constitution of a surface discharge are outlined, and the application of this approach to the study of aircraft lightning strikes is considered. Representations of leader-streamer and return-stroke phases are discussed, and the application to the two-dimensional discharge phase is covered. It is noted that the fact that the initiation times of surface discharges could be controlled, and the path followed by the discharge channels could be predetermined, indicates that it is possible to produce a highly dedicated high performance instrumentation system.

  6. Heart failure diagnosis in acute conditions has high agreement with inpatient diagnosis.

    PubMed

    Seronde, Marie-France; Laribi, Said; Collins, Sean P; Deye, Nicolas; Logeart, Damien; Plaisance, Patrick; Cohen-Solal, Alain; Mebazaa, Alexandre

    2016-06-01

    Acute heart failure (AHF) is frequently encountered in the emergency department (ED) or in the cardiac care unit (CCU)/ICU. Discrimination between cardiac and noncardiac cause of dyspnea by clinical means and standard testing is sometimes inadequate. The aim of our study was to assess AHF diagnosis agreement as determined by: (a) the attending physician, (b) the hospital discharge diagnosis, and (c) an adjudication committee. Between 2010 and 2011, consecutive patients arriving for dyspnea in our hospital were prospectively included. A convenience sample of patients was enrolled in this analysis. Patients were admitted through the ED (280 patients) or through CCU/ICU (112 patients) for undifferentiated dyspnea. Overall, few differences were observed between the initial diagnosis and the hospital discharge diagnosis or the adjudicated diagnosis. Among the 200 patients with an initial diagnosis of AHF, hospital discharge diagnosis confirmed AHF (alone or combined) in 191 (95.5%) patients and the adjudication committee confirmed AHF (alone or combined) in 196 (98%) patients. Our study showed considerable agreement between different AHF diagnostic standards. An initial AHF diagnosis on the basis of clinical signs and biological parameters utilizing B-type natriuretic peptide testing has high agreement and accuracy with the hospital discharge and adjudicated diagnosis of AHF. The present study also shows that the accuracy of the initial AHF diagnosis allows rapid inclusion in AHF trials. These results, if confirmed in a broader cohort of patients, suggest that the initial ED diagnosis is highly accurate and reliable to guide further inpatient management.

  7. Microwave-induced electrostatic etching: generation of highly reactive magnesium for application in Grignard reagent formation.

    PubMed

    van de Kruijs, Bastiaan H P; Dressen, Mark H C L; Meuldijk, Jan; Vekemans, Jef A J M; Hulshof, Lumbertus A

    2010-04-07

    A detailed study regarding the influence of microwave irradiation on the formation of a series of Grignard reagents in terms of rates and selectivities has revealed that these heterogeneous reactions may display a beneficial microwave effect. The interaction between microwaves and magnesium turnings generates violent electrostatic discharges. These discharges on magnesium lead to melting of the magnesium surface, thus generating highly active magnesium particles. As compared to conventional operation the microwave-induced discharges on the magnesium surface lead to considerably shorter initiation times for the insertion of magnesium in selected substrates (i.e. halothiophenes, halopyridines, octyl halides, and halobenzenes). Thermographic imaging and surface characterization by scanning electron microscopy showed that neither selective heating nor a "specific" microwave effect was causing the reduction in initiation times. This novel and straightforward initiation method eliminates the use of toxic and environmentally adverse initiators. Thus, this initiation method limits the formation of by-products. We clearly demonstrated that microwave irradiation enables fast Grignard reagent formation. Therefore, microwave technology is promising for process intensification of Grignard based coupling reactions.

  8. Runaway breakdown and hydrometeors in lightning initiation.

    PubMed

    Gurevich, A V; Karashtin, A N

    2013-05-03

    The particular electric pulse discharges are observed in thunderclouds during the initiation stage of negative cloud-to-ground lightning. The discharges are quite different from conventional streamers or leaders. A detailed analysis reveals that the shape of the pulses is determined by the runaway breakdown of air in the thundercloud electric field initiated by extensive atmospheric showers (RB-EAS). The high amplitude of the pulse electric current is due to the multiple microdischarges at hydrometeors stimulated and synchronized by the low-energy electrons generated in the RB-EAS process. The series of specific pulse discharges leads to charge reset from hydrometeors to the free ions and creates numerous stretched ion clusters, both positive and negative. As a result, a wide region in the thundercloud with a sufficiently high fractal ion conductivity is formed. The charge transport by ions plays a decisive role in the lightning leader preconditioning.

  9. Surface-initiated graft polymerization on multiwalled carbon nanotubes pretreated by corona discharge at atmospheric pressure.

    PubMed

    Xu, Lihua; Fang, Zhengping; Song, Ping'an; Peng, Mao

    2010-03-01

    Surface-initiated graft polymerization on multi-walled carbon nanotubes pretreated with a corona discharge at atmospheric pressure was explored. The mechanism of the corona-discharge-induced graft polymerization is discussed. The results indicate that MWCNTs were encapsulated by poly(glycidyl methacrylate) (PGMA), demonstrating the formation of PGMA-grafted MWCNTs (PGMA-g-MWCNTs), with a grafting ratio of about 22 wt%. The solubility of PGMA-g-MWCNTs in ethanol was dramatically improved compared to pristine MWCNTs, which could contribute to fabricating high-performance polymer/MWCNTs nanocomposites in the future. Compared with most plasma processes, which operate at low pressures, corona discharge has the merit of working at atmospheric pressure.

  10. Rationale and design of TRANSITION: a randomized trial of pre‐discharge vs. post‐discharge initiation of sacubitril/valsartan

    PubMed Central

    Wachter, Rolf; Senni, Michele; Belohlavek, Jan; Noè, Adele; Carr, David; Butylin, Dmytro

    2017-01-01

    Abstract Aims The prognosis after hospitalization for acute decompensated heart failure (ADHF) remains poor, especially <30 days post‐discharge. Evidence‐based medications with prognostic impact administered at discharge improve survival and hospital readmission, but robust studies comparing pre‐discharge with post‐discharge initiation are rare. The PARADIGM‐HF trial established sacubitril/valsartan as a new evidence‐based therapy in patients with heart failure (HF) and reduced left ventricular ejection fraction (<40%) (rEF). In common with other landmark studies, it enrolled patients who were ambulatory at the time of inclusion. In addition, there is also still limited knowledge of initiation and up‐titration of sacubitril/valsartan in ACEi/ARB‐ naïve patients and in de novo HF with rEF patients. Methods and results TRANSITION is a multicentre, open‐label study in which ~1000 adults hospitalized for ADHF with rEF are randomized to start sacubitril/valsartan in a pre‐discharge arm (initiated ≥24 h after haemodynamic stabilization) or a post‐discharge arm (initiated within Days 1–14 after discharge). The protocol allows investigators to select the appropriate starting dose and dose adjustments according to clinical circumstances. Over a 10 week treatment period, the primary and secondary objectives assess the feasibility and safety of starting sacubitril/valsartan in‐hospital, early after haemodynamic stabilization. Exploratory objectives also include assessment of HF signs and symptoms, readmissions, N‐terminal pro‐B‐type natriuretic peptide and high‐sensitivity troponin T levels, and health resource utilization parameters. Conclusions TRANSITION will provide new evidence about initiating sacubitril/valsartan following hospitalization for ADHF, occurring either as de novo ADHF or as deterioration of chronic HF, and in patients with or without prior ACEI/ARB therapy. The results of TRANSITION will thus be highly relevant to the management of patients hospitalized for ADHF with rEF. PMID:29239515

  11. Assessing medication adherence and healthcare utilization and cost patterns among hospital-discharged patients with schizoaffective disorder.

    PubMed

    Karve, Sudeep; Markowitz, Michael; Fu, Dong-Jing; Lindenmayer, Jean-Pierre; Wang, Chi-Chuan; Candrilli, Sean D; Alphs, Larry

    2014-06-01

    Hospital-discharged patients with schizoaffective disorder have a high risk of re-hospitalization. However, limited data exist evaluating critical post-discharge periods during which the risk of re-hospitalization is significant. Among hospital-discharged patients with schizoaffective disorder, we assessed pharmacotherapy adherence and healthcare utilization and costs during sequential 60-day clinical periods before schizoaffective disorder-related hospitalization and post-hospital discharge. From the MarketScan(®) Medicaid database (2004-2008), we identified patients (≥18 years) with a schizoaffective disorder-related inpatient admission. Study measures including medication adherence and healthcare utilization and costs were assessed during sequential preadmission and post-discharge periods. We conducted univariate and multivariable regression analyses to compare schizoaffective disorder-related and all-cause healthcare utilization and costs (in 2010 US dollars) between each adjacent 60-day post-discharge periods. No adjustment was made for multiplicity. We identified 1,193 hospital-discharged patients with a mean age of 41 years. The mean medication adherence rate was 46% during the 60-day period prior to index inpatient admission, which improved to 80% during the 60-day post-discharge period. Following hospital discharge, schizoaffective disorder-related healthcare costs were significantly greater during the initial 60-day period compared with the 61- to 120-day post-discharge period (mean US$2,370 vs US$1,765; p < 0.001), with rehospitalization (36%) and pharmacy (40%) accounting for over three-fourths of the initial 60-day period costs. Compared with the initial 60-day post-discharge period, both all-cause and schizoaffective disorder-related costs declined during the 61- to 120-day post-discharge period and remained stable for the remaining post-discharge periods (days 121-365). We observed considerably lower (46%) adherence during 60 days prior to the inpatient admission; in comparison, adherence for the overall 6-month period was 8% (54%) higher. Our study findings suggest that both short-term (e.g., 60 days) and long-term (e.g., 6-12 months) medication adherence likely are important characteristics to examine among patients with schizoaffective disorder and help provide a more holistic view of patients' adherence patterns. Furthermore, we observed a high rate of rehospitalization and greater healthcare costs during the initial 60-day period post-discharge among patients with schizoaffective disorder. Further research is required to better understand and manage transitional care after discharge (e.g., monitor adherence), which may help reduce the likelihood of rehospitalization and the associated downstream costs.

  12. Dependence of Initial Oxygen Concentration on Ozone Yield Using Inductive Energy Storage System Pulsed Power Generator

    NASA Astrophysics Data System (ADS)

    Go, Tomio; Tanaka, Yasushi; Yamazaki, Nobuyuki; Mukaigawa, Seiji; Takaki, Koichi; Fujiwara, Tamiya

    Dependence of initial oxygen concentration on ozone yield using streamer discharge reactor driven by an inductive energy storage system pulsed power generator is described in this paper. Fast recovery type diodes were employed as semiconductor opening switch to interrupt a circuit current within 100 ns. This rapid current change produced high-voltage short pulse between a secondary energy storage inductor. The repetitive high-voltage short pulse was applied to a 1 mm diameter center wire electrode placed in a cylindrical pulse corona reactor. The streamer discharge successfully occurred between the center wire electrode and an outer cylinder ground electrode of 2 cm inner diameter. The ozone was produced with the streamer discharge and increased with increasing pulse repetition rate. The ozone yield changed in proportion to initial oxygen concentration contained in the injected gas mixture at 800 ns forward pumping time of the current. However, the decrease of the ozone yield by decreasing oxygen concentration in the gas mixture at 180 ns forward pumping time of the current was lower than the decrease at 800 ns forward pumping time of the current. This dependence of the initial oxygen concentration on ozone yield at 180 ns forward pumping time is similar to that of dielectric barrier discharge reactor.

  13. Lightning discharges produced by wind turbines

    NASA Astrophysics Data System (ADS)

    Montanyà, Joan; van der Velde, Oscar; Williams, Earle R.

    2014-02-01

    New observations with a 3-D Lightning Mapping Array and high-speed video are presented and discussed. The first set of observations shows that under certain thunderstorm conditions, wind turbine blades can produce electric discharges at regular intervals of 3 s in relation to its rotation, over periods of time that range from a few minutes up to hours. This periodic effect has not been observed in static towers indicating that the effect of rotation is playing a critical role. The repeated discharges can occur tens of kilometers away from electrically active thunderstorm areas and may or may not precede a fully developed upward lightning discharge from the turbine. Similar to rockets used for triggering lightning, the fast movement of the blade tip plays an important role on the initiation of the discharge. The movement of the rotor blades allows the tip to "runaway" from the generated corona charge. The second observation is an uncommon upward/downward flash triggered by a wind turbine. In that flash, a negative upward leader was initiated from a wind turbine without preceding lightning activity. The flash produced a negative cloud-to-ground stroke several kilometers from the initiation point. The third observation corresponds to a high-speed video record showing simultaneous upward positive leaders from a group of wind turbines triggered by a preceding intracloud flash. The fact that multiple leaders develop simultaneously indicates a poor shielding effect among them. All these observations provide some special features on the initiation of lightning by nonstatic and complex tall structures.

  14. Reversing-counterpulse repetitive-pulse inductive storage circuit

    DOEpatents

    Honig, Emanuel M.

    1987-01-01

    A high-power reversing-counterpulse repetitive-pulse inductive storage and transfer circuit includes an opening switch, a main energy storage coil, a counterpulse capacitor and a small inductor. After counterpulsing the opening switch off, the counterpulse capacitor is recharged by the main energy storage coil before the load pulse is initiated. This gives the counterpulse capacitor sufficient energy for the next counterpulse operation, although the polarity of the capacitor's voltage must be reversed before that can occur. By using a current-zero switch as the counterpulse start switch, the capacitor is disconnected from the circuit (with a full charge) when the load pulse is initiated, preventing the capacitor from depleting its energy store by discharging through the load. After the load pulse is terminated by reclosing the main opening switch, the polarity of the counterpulse capacitor voltage is reversed by discharging the capacitor through a small inductor and interrupting the discharge current oscillation at zero current and peak reversed voltage. The circuit enables high-power, high-repetition-rate operation with reusable switches and features total control (pulse-to-pulse) over output pulse initiation, duration, repetition rate, and, to some extent, risetime.

  15. Reversing-counterpulse repetitive-pulse inductive storage circuit

    DOEpatents

    Honig, E.M.

    1984-06-05

    A high power reversing-counterpulse repetitive-pulse inductive storage and transfer circuit includes an opening switch, a main energy storage coil, a counterpulse capacitor and a small inductor. After counterpulsing the opening switch off, the counterpulse capacitor is recharged by the main energy storage coil before the load pulse is initiated. This gives the counterpulse capacitor sufficient energy for the next counterpulse operation, although the polarity of the capacitor's voltage must be reversed before that can occur. By using a current-zero switch as the counterpulse start switch, the capacitor is disconnected from the circuit (with a full charge) when the load pulse is initiated, preventing the capacitor from depleting its energy store by discharging through the load. After the load pulse is terminated by reclosing the main opening switch, the polarity of the counterpulse capacitor voltage is reversed by discharging the capacitor through a small inductor and interrupting the discharge current oscillation at zero current and peak reversed voltage. The circuit enables high-power, high-repetition-rate operation with reusable switches and features total control (pulse-to-pulse) over output pulse initiation, duration, repetition rate, and, to some extent, risetime.

  16. Observations of the initial stage of a rocket-and-wire-triggered lightning discharge

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Krehbiel, Paul R.; Zhang, Yijun; Lu, Weitao; Zheng, Dong; Xu, Liangtao; Huang, Zhigang

    2017-05-01

    Observations have been obtained of the initial stage of a rocket-and-wire-triggered lightning flash with a high-resolution broadband VHF interferometer. The discharge produced 54 precursor current pulses (PCPs) over 883 ms during the rocket's ascent. The interferometer observations show that the PCPs were produced by breakdown at the ascending tip of the rocket, and that individual PCPs were produced by weak upward positive breakdown over meters-scale distances, followed by more energetic, fast downward negative breakdown over several tens of meters distance. The average propagation speeds were 5 × 106 m s-1 and 3 × 107 m s-1, respectively. The sustained upward positive leader (UPL) was initiated by a rapid, repetitive burst of 14 precursor pulses. Upon initiation, the VHF radiation abruptly became continuous with time. Significantly, breakdown during the UPL appeared to extend the discharge in a similar manner to that of the precursor pulses.

  17. A trial of ignition innovation of gasoline engine by nanosecond pulsed low temperature plasma ignition

    NASA Astrophysics Data System (ADS)

    Shiraishi, Taisuke; Urushihara, Tomonori; Gundersen, Martin

    2009-07-01

    Application of nanosecond pulsed low temperature plasma as an ignition technique for automotive gasoline engines, which require a discharge under conditions of high back pressure, has been studied experimentally using a single-cylinder engine. The nanosecond pulsed plasma refers to the transient (non-equilibrated) phase of a plasma before the formation of an arc discharge; it was obtained by applying a high voltage with a nanosecond pulse (FWHM of approximately 80 or 25 ns) between coaxial cylindrical electrodes. It was confirmed that nanosecond pulsed plasma can form a volumetric multi-channel streamer discharge at an energy consumption of 60 mJ cycle-1 under a high back pressure of 1400 kPa. It was found that the initial combustion period was shortened compared with the conventional spark ignition. The initial flame visualization suggested that the nanosecond pulsed plasma ignition results in the formation of a spatially dispersed initial flame kernel at a position of high electric field strength around the central electrode. It was observed that the electric field strength in the air gap between the coaxial cylindrical electrodes was increased further by applying a shorter pulse. It was also clarified that the shorter pulse improved ignitability even further.

  18. Electron beam switched discharge for rapidly pulsed lasers

    DOEpatents

    Pleasance, Lyn D.; Murray, John R.; Goldhar, Julius; Bradley, Laird P.

    1981-01-01

    Method and apparatus for electrical excitation of a laser gas by application of a pulsed voltage across the gas, followed by passage of a pulsed, high energy electron beam through the gas to initiate a discharge suitable for laser excitation. This method improves upon current power conditioning techniques and is especially useful for driving rare gas halide lasers at high repetition rates.

  19. Numerical study of nonequilibrium plasma assisted detonation initiation in detonation tube

    NASA Astrophysics Data System (ADS)

    Zhou, Siyin; Wang, Fang; Che, Xueke; Nie, Wansheng

    2016-12-01

    Nonequilibrium plasma has shown great merits in ignition and combustion nowadays, which should be especially useful for hypersonic propulsion. A coaxial electrodes configuration was established to investigate the effect of alternating current (AC) dielectric barrier discharge nonequilibrium plasma on the detonation initiation process in a hydrogen-oxygen mixture. A discharge simulation-combustion simulation loosely coupled method was used to simulate plasma assisted detonation initiation. First, the dielectric barrier discharge in the hydrogen-oxygen mixture driven by an AC voltage was simulated, which takes 17 kinds of particles (including positively charged particles, negatively charged particles, and neutral particles) and 47 reactions into account. The temporal and spatial characteristics of the discharge products were obtained. Then, the discharge products were incorporated into the combustion model of a detonation combustor as the initial conditions for the later detonation initiation simulation. Results showed that the number density distributions of plasma species are different in space and time, and develop highly nonuniformly from high voltage electrode to grounded electrode at certain times. All the active species reach their highest concentration at approximately 0.6T (T denotes a discharge cycle). Compared with the no plasma case, the differences of flowfield shape mainly appear in the early stage of the deflagration to detonation transition process. None of the sub-processes (including the very slow combustion, deflagration, over-driven detonation, detonation decay, and propagation of a self-sustained stable detonation wave) have been removed by the plasma. After the formation of a C-J detonation wave, the whole flowfield remains unchanged. With the help of plasma, the deflagration to detonation transition (DDT) time and distance are reduced by about 11.6% and 12.9%, respectively, which should be attributed to the active particles effect of nonequilibrium plasma and the local turbulent enhancing effect by the spatial characteristics of discharge. In addition, as the duration of forming a shock wave in the combustor is shortened by approximately 8.1%, it can be inferred that the plasma accelerates the DDT process more significantly before the flow becomes supersonic.

  20. Effects of discharge parameters on the micro-hollow cathode sustained glow discharge

    NASA Astrophysics Data System (ADS)

    Shoujie, HE; Peng, WANG; Jing, HA; Baoming, ZHANG; Zhao, ZHANG; Qing, LI

    2018-05-01

    The effects of parameters such as pressure, first anode radius, and the cavity diameter on the micro-hollow cathode sustained glow discharge are investigated by using a two-dimensional self-consistent fluid model in pure argon. The results indicate that the three parameters influence the discharge in the regions inside and outside of the cavity. Under a fixed voltage on each electrode, a larger volume of high density plasma can be produced in the region between the first and the second anodes by selecting the appropriate pressure, the higher first anode, and the appropriate cavity diameter. As the pressure increases, the electron density inside the hollow cathode, the high density plasma volume between the first anode and second anodes, and the radial electric field in the cathode cavity initially increase and subsequently decrease. As the cavity diameter increases, the high-density plasma volume between the first and second anodes initially increases and subsequently decreases; whereas the electron density inside the hollow cathode decreases. As the first anode radius increases, the electron density increases both inside and outside of the cavity. Moreover, the increase of the electron density is more obvious in the microcathode sustained region than in the micro cavity region. The results reveal that the discharge inside the cavity interacts with that outside the cavity. The strong hollow cathode effect and the high-density plasma inside the cavity favor the formation of a sustained discharge between the first anode and the second anodes. Results also show that the radial boundary conditions exert a considerably weaker influence on the discharge except for a little change in the region close to the radial boundary.

  1. Electron beam-switched discharge for rapidly pulsed lasers

    DOEpatents

    Pleasance, L.D.; Murray, J.R.; Goldhar, J.; Bradley, L.P.

    1979-12-11

    A method and apparatus are designed for electrical excitation of a laser gas by application of a pulsed voltage across the gas, followed by passage of a pulsed, high energy electron beam through the gas to initiate a discharge suitable for laser excitation. This method improves upon current power conditioning techniques and is especially useful for driving rare gas halide lasers at high repetition rates.

  2. Plasma Assisted Ignition and Combustion at Low Initial Gas Temperatures: Development of Kinetic Mechanism

    DTIC Science & Technology

    2016-10-05

    of these species experimentally challenging. In these cases , TALIF is a good alternative. The energy levels used in this study are shown in Fig. 2.1...flame velocities achieved in lean mixtures (ER=0.5 in our experimental case ) can be an interesting issue for industrial applications. One of the possible...dielectric barrier discharge (nSDBD) was studied experimentally at high initial pressures P = 3 − 6 bar. The discharge was studied in different gas mixtures

  3. Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

    NASA Technical Reports Server (NTRS)

    Kendall, B. R. F.

    1983-01-01

    A specialized spectrometer was designed and developed to measure the mass and velocity distributions of neutral particles (molecules and molecular clusters) released from metal-backed Teflon and Kapton films. Promising results were obtained with an insulation breakdown initiation system based on a moveable contact touching the insulated surfaces. A variable energy, high voltage pulse is applied to the contact. The resulting surface damage sites can be made similar in size and shape to those produced by a high voltage electron beam system operating at similar discharge energies. The point discharge apparatus was used for final development of several high speed recording systems and for measurements of the composition of the materials given off by the discharge. Results with this apparatus show evolution of large amounts of fluorocarbon fragments from discharge through Teflon FEP, while discharges through Kapton produce mainly very light hydrocarbon fragments at masses below about 80 a.m.u.

  4. Reversing-counterpulse repetitive-pulse inductive storage circuit

    DOEpatents

    Honig, E.M.

    1987-02-10

    A high-power reversing-counterpulse repetitive-pulse inductive storage and transfer circuit includes an opening switch, a main energy storage coil, a counterpulse capacitor and a small inductor. After counterpulsing the opening switch off, the counterpulse capacitor is recharged by the main energy storage coil before the load pulse is initiated. This gives the counterpulse capacitor sufficient energy for the next counterpulse operation, although the polarity of the capacitor's voltage must be reversed before that can occur. By using a current-zero switch as the counterpulse start switch, the capacitor is disconnected from the circuit (with a full charge) when the load pulse is initiated, preventing the capacitor from depleting its energy store by discharging through the load. After the load pulse is terminated by reclosing the main opening switch, the polarity of the counterpulse capacitor voltage is reversed by discharging the capacitor through a small inductor and interrupting the discharge current oscillation at zero current and peak reversed voltage. The circuit enables high-power, high-repetition-rate operation with reusable switches and features total control (pulse-to-pulse) over output pulse initiation, duration, repetition rate, and, to some extent, risetime. 10 figs.

  5. On the road to self-sputtering in high power impulse magnetron sputtering: particle balance and discharge characteristics

    NASA Astrophysics Data System (ADS)

    Huo, Chunqing; Lundin, Daniel; Raadu, Michael A.; Anders, André; Tomas Gudmundsson, Jon; Brenning, Nils

    2014-04-01

    The onset and development of self-sputtering (SS) in a high power impulse magnetron sputtering (HiPIMS) discharge have been studied using a plasma chemical model and a set of experimental data, taken with an aluminum target and argon gas. The model is tailored to duplicate the discharge in which the data are taken. The pulses are long enough to include both an initial transient and a following steady state. The model is used to unravel how the internal discharge physics evolves with pulse power and time, and how it is related to features in the discharge current-voltage-time characteristics such as current densities, maxima, kinks and slopes. The connection between the self-sputter process and the discharge characteristics is quantified and discussed in terms of three parameters: a critical target current density Jcrit based on the maximum refill rate of process (argon) gas above the target, an SS recycling factor ΠSS-recycle, and an approximation \\tilde{\\alpha} of the probabilities of ionization of species that come from the target (both sputtered metal and embedded argon atoms). For low power pulses, discharge voltages UD ⩽ 380 V with peak current densities below ≈ 0.2 A cm-2, the discharge is found to be dominated by process gas sputtering. In these pulses there is an initial current peak in time, associated with partial gas rarefaction, which is followed by a steady-state-like plateau in all parameters similar to direct current magnetron sputtering. In contrast, high power pulses, with UD ⩾ 500 V and peak current densities above JD ≈ 1.6 A cm-2, make a transition to a discharge mode where SS dominates. The transition is found not to be driven by process gas rarefaction which is only about 10% at this time. Maximum gas rarefaction is found later in time and always after the initial peak in the discharge current. With increasing voltage, and pulse power, the discharge can be described as following a route where the role of SS increases in four steps: process gas sputtering, gas-sustained SS, self-sustained SS and SS runaway. At the highest voltage, 1000 V, the discharge is very close to, but does not go into, the SS runaway mode. This absence of runaway is proposed to be connected to an unexpected finding: that twice ionized ions of the target species play almost no role in this discharge, not even at the highest powers. This reduces ionization by secondary-emitted energetic electrons almost to zero in the highest power range of the discharge.

  6. Hospital readmission risks in older adults following inpatient subacute care: A six-month follow-up study.

    PubMed

    Lee, Den-Ching A; Williams, Cylie; Lalor, Aislinn F; Brown, Ted; Haines, Terry P

    2018-05-09

    High rates of unplanned hospital readmissions are a burden on healthcare systems and individuals. This study examined factors at, and after initial hospital discharge and their associations with unplanned hospital readmission for older adults up to six months post-discharge from subacute care. Older subacute care patients were surveyed prior to discharge, and assessed monthly post-discharge for six months. Data included the Geriatric Depression Scale, Phone-Fitt sub-scales, Friendship Scale, modified Lubben Social Network Scale, unplanned hospital readmission, self-reported physical capacity and falls in the last month were collected. Regression analyses were used to examine relationships between unplanned hospital readmission and variables that may predispose this outcome. Participants (n = 311) completed the baseline assessment. N = 218 (70%) completed all at six-month post-discharge. Eighty-nine (29%) participants shared 143 readmissions. Those with cancer history (adjusted OR [95% CI]) (1.97 [1.15, 3.39]), neurological disease other than stroke (2.95 [1.32, 6.57]) and dependence on others to assist in bending tasks (1.94 [1.14, 3.29]) at initial discharge were associated with readmission within six months post-discharge. Those who fell in the last month (adjusted OR [robust 95% CI]) (2.28 [1.43, 3.64]), being less physical active (0.98 [0.96, 0.99]), and dependence on others in moving around residence (2.63 [1.37, 5.06]) after initial discharge were associated with a readmission in the next month within six months post-discharge. Trials investigating the effectiveness of strategies to reduce falls, build physical capacity, increase physical activity level, and connection with health care services after discharge to prevent readmission are warranted. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. High-order harmonic generation in a capillary discharge

    DOEpatents

    Rocca, Jorge J.; Kapteyn, Henry C.; Mumane, Margaret M.; Gaudiosi, David; Grisham, Michael E.; Popmintchev, Tenio V.; Reagan, Brendan A.

    2010-06-01

    A pre-ionized medium created by a capillary discharge results in more efficient use of laser energy in high-order harmonic generation (HHG) from ions. It extends the cutoff photon energy, and reduces the distortion of the laser pulse as it propagates down the waveguide. The observed enhancements result from a combination of reduced ionization energy loss and reduced ionization-induced defocusing of the driving laser as well as waveguiding of the driving laser pulse. The discharge plasma also provides a means to spectrally tune the harmonics by tailoring the initial level of ionization of the medium.

  8. Patterns of beta-blocker intensification in ambulatory heart failure patients and short-term association with hospitalization

    PubMed Central

    2012-01-01

    Background In response to the short-term negative inotropic and chronotropic effects of β-blockers, heart failure (HF) guidelines recommend initiating β-blockers at low dose with gradual uptitration as tolerated to doses used in clinical trials. However, patterns and safety of β-blocker intensification in routine practice are poorly described. Methods We described β-blocker intensification among Kaiser Colorado enrollees with a primary discharge diagnosis of HF between 2001–2009. We then assessed β-blocker intensification in the 30 days prior to first hospital readmission for cases compared to the same time period following index hospitalization for non-rehospitalized matched controls. In separate analysis of the subgroup initiated on β-blocker after index hospital discharge, we compared adjusted rates of 30-day hospitalization following initiation of high versus low dose β-blocker. Results Among 3,227 patients, median age was 76 years and 37% had ejection fraction ≤40% (LVSD). During a median follow up of 669 days, 14% were never on β-blocker, 21% were initiated on β-blocker, 43% were discharged on β-blocker but never uptitrated, and 22% had discharge β-blocker uptitrated; 63% were readmitted and 49% died. β-blocker intensification occurred in the 30 days preceding readmission for 39 of 1,674 (2.3%) readmitted cases compared to 27 (1.6%) of matched controls (adjusted OR 1.36, 95% CI 0.81-2.27). Among patients initiated on therapy, readmission over the subsequent 30 days occurred in 6 of 155 (3.9%) prescribed high dose and 9 of 513 (1.8%) prescribed low dose β-blocker (adjusted OR 3.10, 95% CI 1.02-9.40). For the subgroup with LVSD, findings were not significantly different. Conclusion While β-blockers were intensified in nearly half of patients following hospital discharge and high starting dose was associated with increased readmission risk, the prevailing finding was that readmission events were rarely preceded by β-blocker intensification. These data suggest that β-blocker intensification is not a major precipitant of hospitalization, provided recommended dosing is followed. PMID:22709128

  9. Triggering regime of oil-filled trigatron dischargers

    NASA Astrophysics Data System (ADS)

    Kapishnikov, N. K.; Muratov, V. M.

    1986-11-01

    A comparative analysis made in [1, 2] of different types of regulable high-voltage dischargers with liquid insulation showed that trigatrons are currently the most promising for use in high-voltage pulse-operated devices due to their simplicity and reliability. Two basic mechanisms of discharge initiation can be realized in trigatrons — initiation by intensification of the field in the region of the control electrode [2, 3], and triggering by a spark in the ignition gap [4, 5]. The first type of trigatron has been studied sufficiently only for short voltage periods [3, 6, 7], so it is used mainly in switching the pulse-shaping lines of powerful nanosecond pulse generators with “rapid” (0.5 1.5 μsec) charging [8, 9]. Almost no use is now made of the second type of trigatron switch in high-voltage pulse technology due to its unsatisfactory time characteristics. Here we report results of a study of the time characteristics of both types of oil-filled trigatrons operating in a regime whereby they form the leading edge of rectangular voltage pulses with amplitudes up to 800 kV and durations of 1 100 μsec. The goal is to find the optimum conditions for triggering of trigatron dischargers with liquid insulation in the region of microsecond voltage discharges. Experiments were conducted on the unit in [10]. The test discharger was placed in a cylindrical chamber 45 cm in diameter and 27 cm in length. The high-voltage electrode of the discharger was in the form of a cylinder 20 cm in diameter positioned coaxially inside the chamber. The 10-mm-diameter ground electrode was positioned radially in a branch pipe 8 cm long. The control electrode was placed in a 2-cm-diameter hole in the center of the ground electrode. The chamber with the test discharge was filled with transformer oil with a breakdown voltage of about 50 kV. The oil was not replaced or cleaned during the experiment. We did not find that contamination of the oil by discharge products had any effect on the time characteristics of either type of discharger. The results were analyzed by the least squares method, with 50 measurements to a point (it was found that time lag of the discharger triggering conforms approximately to a normal distribution law for both types of discharger).

  10. High-Temperature Electrochemical Performance of FeF3/C Nanocomposite as a Cathode Material for Lithium-Ion Batteries

    NASA Astrophysics Data System (ADS)

    Tang, Mengyun; Zhang, Zhengfu; Wang, Zi; Liu, Jingfeng; Yan, Hongge; Peng, Jinhui

    2018-02-01

    Iron trifluoride has been studied as a cathode material due to its cost-effectiveness, low toxicity, and high theoretical capacities of 712 mA h g-1. However, FeF3 has serious shortcomings of poor electronic conductivity and a slow diffusion rate of lithium ions, leading to a lower reversible specific capacity. In this work, FeF3/C nanocomposite has been synthesized successfully via a high-energy ball-milling method, and acetylene black is used as the conductive agent to improve the conductivity of FeF3. The FeF3/C nanocomposite shows a high initial discharge capacity of 346.25 and 161.58 mA h g-1 after 40th cycle at 50 mA g-1. It exhibits good cycle performance and rate performance. The high-temperature discharge capacities decreased with increase in the temperature. The initial high-temperature discharge capacities are found to be 254.17, 300.01, 281.25 and 125.16, and 216.875, 156, 141.67, 150, and 64.98 mA h g-1 at 20th cycles at the 40, 50, 60, and 70 °C, respectively.

  11. Schlieren optical visualization for transient EHD induced flow in a stratified dielectric liquid under gas-phase ac corona discharges

    NASA Astrophysics Data System (ADS)

    Ohyama, R.; Inoue, K.; Chang, J. S.

    2007-01-01

    A flow pattern characterization of electrohydrodynamically (EHD) induced flow phenomena of a stratified dielectric fluid situated in an ac corona discharge field is conducted by a Schlieren optical system. A high voltage application to a needle-plate electrode arrangement in gas-phase normally initiates a conductive type EHD gas flow. Although the EHD gas flow motion initiated from the corona discharge electrode has been well known as corona wind, no comprehensive study has been conducted for an EHD fluid flow motion of the stratified dielectric liquid that is exposed to the gas-phase ac corona discharge. The experimentally observed result clearly presents the liquid-phase EHD flow phenomenon induced from the gas-phase EHD flow via an interfacial momentum transfer. The flow phenomenon is also discussed in terms of the gas-phase EHD number under the reduced gas pressure (reduced interfacial momentum transfer) conditions.

  12. About Losses in Pumping Generators of High-Power Electrodischarge Excimer Lasers

    NASA Astrophysics Data System (ADS)

    Ivanov, N. G.; Losev, V. F.

    2015-04-01

    Energy losses in pumping systems of discharge high-power lasers are investigated. To estimate the losses, the discharge circuit operation was modeled, and its calculation was performed using the program PSpice. Results of measurements and calculations demonstrate that the resistance of a rail gap with electric field distortion exceeds several times the resistance of a single-channel gap without field distortion. A difference in the resistances is explained by different mechanisms of discharge burning: in the first case diffusion mechanism and in the second case the spark mechanism. The low efficiency of the high-power excimer lasers (~1%) is explained by high energy losses in the rail gap that reach more than 50% of the initially stored energy.

  13. High voltage spark carbon fiber detection system

    NASA Technical Reports Server (NTRS)

    Yang, L. C.

    1980-01-01

    The pulse discharge technique was used to determine the length and density of carbon fibers released from fiber composite materials during a fire or aircraft accident. Specifications are given for the system which uses the ability of a carbon fiber to initiate spark discharge across a high voltage biased grid to achieve accurate counting and sizing of fibers. The design of the system was optimized, and prototype hardware proved satisfactory in laboratory and field tests.

  14. Electrical treeing behaviors in silicone rubber under an impulse voltage considering high temperature

    NASA Astrophysics Data System (ADS)

    Yunxiao, ZHANG; Yuanxiang, ZHOU; Ling, ZHANG; Zhen, LIN; Jie, LIU; Zhongliu, ZHOU

    2018-05-01

    In this paper, work was conducted to reveal electrical tree behaviors (initiation and propagation) of silicone rubber (SIR) under an impulse voltage with high temperature. Impulse frequencies ranging from 10 Hz to 1 kHz were applied and the temperature was controlled between 30 °C and 90 °C. Experimental results show that tree initiation voltage decreases with increasing pulse frequency, and the descending amplitude is different in different frequency bands. As the pulse frequency increases, more frequent partial discharges occur in the channel, increasing the tree growth rate and the final shape intensity. As for temperature, the initiation voltage decreases and the tree shape becomes denser as the temperature gets higher. Based on differential scanning calorimetry results, we believe that partial segment relaxation of SIR at high temperature leads to a decrease in the initiation voltage. However, the tree growth rate decreases with increasing temperature. Carbonization deposition in the channel under high temperature was observed under microscope and proven by Raman analysis. Different tree growth models considering tree channel characteristics are proposed. It is believed that increasing the conductivity in the tree channel restrains the partial discharge, holding back the tree growth at high temperature.

  15. Three-electrode low pressure discharge apparatus and method for uniform ionization of gaseous media

    DOEpatents

    McLellan, Edward J.

    1983-01-01

    Uniform, transverse electrical discharges are produced in gaseous media without the necessity of switching the main discharge voltage with an external device which carries the entire discharge current. A three-electrode low pressure discharge tube is charged across its anode (1) and cathode (2) to below breakdown voltage using a dc voltage source (3). An array of resistors (4) or capacitors can be made to discharge to the wire screen anode by means of a low energy high voltage pulse circuit (5) producing sufficient preionization in the region between the anode and cathode to initiate and control the main discharge. The invention has been demonstrated to be useful as a CO.sub.2 laser oscillator and pulse-smoother. It can be reliably operated in the sealed-off mode.

  16. Exploration to generate atmospheric pressure glow discharge plasma in air

    NASA Astrophysics Data System (ADS)

    Wenzheng, LIU; Chuanlong, MA; Shuai, ZHAO; Xiaozhong, CHEN; Tahan, WANG; Luxiang, ZHAO; Zhiyi, LI; Jiangqi, NIU; Liying, ZHU; Maolin, CHAI

    2018-03-01

    Atmospheric pressure glow discharge (APGD) plasma in air has high application value. In this paper, the methods of generating APGD plasma in air are discussed, and the characteristics of dielectric barrier discharge (DBD) in non-uniform electric field are studied. It makes sure that APGD in air is formed by DBD in alternating current electric field with using the absorbing electron capacity of electret materials to provide initial electrons and to end the discharge progress. Through designing electric field to form two-dimensional space varying electric field and three-dimensional space varying electric field, the development of electron avalanches in air-gap is suppressed effectively and a large space of APGD plasma in air is generated. Further, through combining electrode structures, a large area of APGD plasma in air is generated. On the other hand, by using the method of increasing the density of initial electrons, millimeter-gap glow discharge in atmospheric pressure air is formed, and a maximum gap distance between electrodes is 8 mm. By using the APGD plasma surface treatment device composed of contact electrodes, the surface modification of high polymer materials such as aramid fiber and polyester are studied and good effect of modifications is obtained. The present paper provides references for the researchers of industrial applications of plasma.

  17. Investigating the effective range of vacuum ultraviolet-mediated breakdown in high-power microwave metamaterials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Chien-Hao, E-mail: cliu82@wisc.edu; Neher, Joel D., E-mail: jdneher@wisc.edu; Booske, John H., E-mail: booske@engr.wisc.edu

    2014-10-14

    Metamaterials and periodic structures operating under high-power excitations are susceptible to breakdown. It was recently demonstrated that a localized breakdown created in a given region of a periodic structure can facilitate breakdown in other regions of the structure where the intensity of the incident electromagnetic fields may not be high enough to cause breakdown under normal circumstances. It was also demonstrated that this phenomenon is due to the generation of vacuum ultraviolet radiation at the location of the initial discharge, which propagates to the neighboring regions (e.g., other unit cells in a periodic structure) and facilitates the generation of amore » discharge at a lower incident power level. In this paper, we present the results of an experimental study conducted to determine the effective range of this physical phenomenon for periodic structures that operate in air and in pure nitrogen gas at atmospheric pressure levels. It is demonstrated that when breakdown is induced in a periodic structure using a high-power pulse with a frequency of 9.382 GHz, duration of 0.8 μs, and peak power level of 25 kW, this phenomenon is highly likely to happen in radii of approximately 16–17 mm from the location of the initial discharge under these test conditions. The results of this study are significant in designing metamaterials and periodic structures for high-power microwave applications as they suggest that a localized discharge created in such a periodic structure with a periodicity less than 16–17 mm can spread over a large surface and result in a distributed discharge.« less

  18. Investigating the reversibility of structural modifications of Li xNi yMn zCo 1-y-zO₂ cathode materials during initial charge/discharge, at multiple length scales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hwang, Sooyeon; Bak, Seong -Min; Kim, Seung Min

    2015-08-11

    In this work, we investigate the structural modifications occurring at the bulk, subsurface, and surface scales of Li xNi yMn zCo 1-y-zO₂ (NMC; y, z = 0.8, 0.1 and 0.4, 0.3, respectively) cathode materials during the initial charge/discharge. Various analytical tools, such as X-ray diffraction, selected-area electron diffraction, electron energy-loss spectroscopy, and high-resolution electron microscopy, are used to examine the structural properties of the NMC cathode materials at the three different scales. Cut-off voltages of 4.3 and 4.8 V are applied during the electrochemical tests as the normal and extreme conditions, respectively. The high-Ni-content NMC cathode materials exhibit unusual behaviors,more » which is deviate from the general redox reactions during the charge or discharge. The transition metal (TM) ions in the high-Ni-content NMC cathode materials, which are mostly Ni ions, are reduced at 4.8 V, even though TMs are usually oxidized to maintain charge neutrality upon the removal of Li. It was found that any changes in the crystallographic and electronic structures are mostly reversible down to the sub-surface scale, despite the unexpected reduction of Ni ions. However, after the discharge, traces of the phase transitions remain at the edges of the NMC cathode materials at the scale of a few nanometers (i.e., surface scale). This study demonstrates that the structural modifications in NMC cathode materials are induced by charge as well as discharge at multiple length scales. These changes are nearly reversible after the first cycle, except at the edges of the samples, which should be avoided because these highly localized changes can initiate battery degradation.« less

  19. Temperature and Nitric Oxide Generation in a Pulsed Arc Discharge Plasma

    NASA Astrophysics Data System (ADS)

    Namihira, T.; Sakai, S.; Matsuda, M.; D., Wang; Kiyan, T.; Akiyama, H.; Okamoto, K.; Toda, K.

    2007-12-01

    Nitric oxide (NO) is increasingly being used in medical treatments of high blood pressure, acute respiratory distress syndrome and other illnesses related to the lungs. Currently a NO inhalation system consists of a gas cylinder of N2 mixed with a high concentration of NO. This arrangement is potentially risky due to the possibility of an accidental leak of NO from the cylinder. The presence of NO in the air leads to the formation of nitric dioxide (NO2), which is toxic to the lungs. Therefore, an on-site generator of NO would be highly desirable for medical doctors to use with patients with lung disease. To develop the NO inhalation system without a gas cylinder, which would include a high concentration of NO, NAMIHIRA et al have recently reported on the production of NO from room air using a pulsed arc discharge. In the present work, the temperature of the pulsed arc discharge plasma used to generate NO was measured to optimize the discharge condition. The results of the temperature measurements showed the temperature of the pulsed arc discharge plasma reached about 10,000 K immediately after discharge initiation and gradually decreased over tens of microseconds. In addition, it was found that NO was formed in a discharge plasma having temperatures higher than 9,000 K and a smaller input energy into the discharge plasma generates NO more efficiently than a larger one.

  20. ELECTRICAL PROTECTIVE DEVICE

    DOEpatents

    Baker, W.R.

    1958-05-01

    A protective system for high-energy resonant cavities is described. It is particularly directed to the discharging of resonant cavities for preventing energy back flow through associated equipment as a result of faults. The invention in general provides means defining a spark gap communicating with the interior of a cavity or waveguide adapted for high-power energization or an evacuated chamber containing an electrode having a large power differential from the wall or other electrode. A control or trigger circuit is connected between a power supply energizing the cavity and the spark gap whereby reverse current flow in the power supply circuit instantaneously triggers the spark gap to initiate discharge within the cavity, whereupon cavity energy discharges across the gap, or with an electrode present the electrode discharges to one of the spark gap elements.

  1. Pore structures in an implantable sol gel titania ceramic device used in controlled drug release applications: A modeling study

    NASA Astrophysics Data System (ADS)

    Peterson, Aaron; Lopez, Tessy; Islas, Emma Ortiz; Gonzalez, Richard D.

    2007-04-01

    Several process variables, which may be helpful in optimizing the rate at which drugs are released from implantable, sol-gel titania devices have been identified in this study. The controlled rate of drug release is compared for two different anticonvulsant drugs, valproic acid and sodic phenytoin. Contrary to what one might expect, when the concentration is increased in the titania reservoir the rate of initial drug delivery decreases. This is a desirable result, because it may reduce the danger of a high initial discharge, which may harm the epileptic rat. The structure of the porous structure within the titania network has been studied using a generalized form of the BET equation which considers only n layers. In general, following an initial discharge, the rate at which the drug is released will increase with the increasing concentration. Pore mouth blocking can present a problem. However, this problem tends to disappear following the initial discharge. The extent of drug loading is a useful variable parameter, which can be adjusted in order to deliver the amount of drug required in a given application.

  2. Three-electrode low pressure discharge apparatus and method for uniform ionization of gaseous media. [CO/sub 2/ laser oscillator and pulse smoother

    DOEpatents

    McLellan, E.J.

    1980-10-17

    Uniform, transverse electrical discharges are produced in gaseous media without the necessity of switching the main discharge voltage with an external device which carries the entire discharge current. A three-electrode low pressure discharge tube is charged across its anode and cathode to below breakdown voltage using a dc voltage source. An array of resistors or capacitors can be made to discharge to the wire screen anode by means of a low energy high voltage pulse circuit producing sufficient preionization in the region between the anode and cathode to initiate and control the main discharge. The invention has been demonstrated to be useful as a CO/sub 2/ laser oscillator and pulse-smoother. It can be reliably operated in the sealed-off mode.

  3. Water dissociation in a radio-frequency electromagnetic field with ex situ electrodes—modelling of discharge initiation

    NASA Astrophysics Data System (ADS)

    Schneider, Jens; Holzer, Frank; Rabe, Carsten; Häupl, Tilmann; Kopinke, Frank-Dieter; Roland, Ulf

    2013-04-01

    Applying a new experimental design with a capillary glass reactor and plate electrodes outside of the reactor allowed the initiation of discharges in aqueous electrolytes under the influence of a radio-frequency (RF) electromagnetic field. This study focused on the mechanism leading to the initiation of such discharges in the restriction of a glass tube. The light emission correlated with discharges was analysed with optical emission spectroscopy. Electrons with energies between 20 and 45 eV were responsible for the dissociation of water molecules into (excited) OH, H and O radicals. Current-voltage characteristics were measured before and under discharge conditions. Modelling of the experimental setup and simulation of electrical field strength distribution support the hypothesis of the origin of discharges in general and experimental findings such as ring-shaped discharges and a minimum solution conductivity of about 1 S m-1 required for discharge initiation with RF voltages of 2 kV.

  4. Impeller tandem blade study with grid embedding for local grid refinement

    NASA Technical Reports Server (NTRS)

    Bache, George

    1992-01-01

    Flow non-uniformity at the discharge of high power density impellers can result in significant unsteady interactions between impeller blades and downstream diffuser vanes. These interactions result in degradation of both performance and pump reliability. The MSFC Pump Technology Team has recognized the importance of resolving this problem and has thus initiated the development and testing of a high head coefficient impeller. One of the primary goals of this program is to improve impeller performance and discharge flow uniformity. The objective of the present work is complimentary. Flow uniformity and performance gains were sought through the application of a tandem blade arrangement. The approach adopted was to numerically establish flow characteristics at the impeller discharge for the baseline MSFC impeller and then parametrically evaluate tandem blade configurations. A tandem design was sought that improves both impeller performance and discharge uniformity. The Navier-Stokes solver AEROVISC was used to conduct the study. Grid embedding is used to resolve local gradients while attempting to minimize model size. Initial results indicate that significant gains in flow uniformity can be achieved through the tandem blade concept and that blade clocking rather than slot location is the primary driver for flow uniformity.

  5. The formation of diffuse discharge by short-front nanosecond voltage pulses and the modification of dielectrics in this discharge

    NASA Astrophysics Data System (ADS)

    Orlovskii, V. M.; Panarin, V. A.; Shulepov, M. A.

    2014-07-01

    The dynamics of diffuse discharge formation under the action of nanosecond voltage pulses with short fronts (below 1 ns) in the absence of a source of additional preionization and the influence of a dielectric film on this process have been studied. It is established that the diffuse discharge is induced by the avalanche multiplication of charge initiated by high-energy electrons and then maintained due to secondary breakdowns propagating via ionized gas channels. If a dielectric film (polyethylene, Lavsan, etc.) is placed on the anode, then multiply repeated discharge will lead to surface and bulk modification of the film material. Discharge-treated polyethylene film exhibits a change in the optical absorption spectrum in the near-IR range.

  6. Clinical prediction of Gardnerella vaginalis in general practice

    PubMed Central

    O'Dowd, T.C.; West, R.R.

    1987-01-01

    In a study of 162 women with vaginal symptoms the clinical features of increased discharge, yellow discharge, 'high cheese' odour and pH greater than 5 were statistically strongly associated with the presence of Gardnerella vaginalis, confirmed by microbiological culture. The sensitivities and specificities of these clinical tests, although not as high as those of previously described sideroom tests using the amine test and microscopy for 'clue cells' nevertheless allow the clinician to predict G. vaginalis reliably and initiate treatment at first consultation. PMID:3499508

  7. Electromagnetic emission from terrestrial lightning in the 0.1-30 MHz frequency range

    NASA Astrophysics Data System (ADS)

    Karashtin, A. N.; Gurevich, A. V.

    Results of measurements carried out at SURA facility of Radiophisical Research Institute and at Tien-Shan Mountain Scientific Station of Lebedev Physical Institute using specially designed installations for short electromagnetic pulse observation in the frequency range from 0.1 to 30 MHz are presented. Specific attention is paid to initial stage of the lightning discharge. It is shown that lightning can be initiated by extensive atmospheric showers caused by high energy cosmic ray particles. Analysis of emission of few thousand lightning discharges showed that • Short wave radio emission of lightning consists of a series of short pulses with duration from less than 100 nanoseconds to several microseconds separated well longer gaps. • Background noise between lightning discharges is not differ from one observed without thunderstorm activity (at given sensitivity). Usually it is the same between lightning pulses at least at the initial stage. • Each lightning discharge radio emission starts with a number of very short (less than 100 nanoseconds at 0.7 level) bi-polar pulses. Gaps between initial pulses vary from several microseconds to few hundreds of microseconds. No radio emission was observed before the first pulse during at least 500 milliseconds. Both positive and negative polarity of the first pulses occur in approximately equal proportion in different lightning discharges while the polarity was the same in any individual lightning. • First pulse amplitude, width and waveform are consistent with predicted by the theory of combined action of runaway breakdown and extensive atmospheric shower caused by cosmic ray particle of 1016 eV energy. Lightning discharges at other planets can be initiated by cosmic ray particles as well. This work was partly supported by ISTC grant # 2236p. The work of one of the authors (A. N. Karashtin) was also partly supported by INTAS grant # 03-51-5727.

  8. Hospitalist and Internal Medicine Leaders' Perspectives of Early Discharge Challenges at Academic Medical Centers.

    PubMed

    Patel, Hemali; Fang, Margaret C; Mourad, Michelle; Green, Adrienne; Wachter, Robert M; Murphy, Ryan D; Harrison, James D

    2018-06-01

    Improving early discharges may improve patient flow and increase hospital capacity. We conducted a national survey of academic medical centers addressing the prevalence, importance, and effectiveness of early-discharge initiatives. We assembled a list of hospitalist and general internal medicine leaders at 115 US-based academic medical centers. We emailed each institutional representative a 30-item online survey regarding early-discharge initiatives. The survey included questions on discharge prioritization, the prevalence and effectiveness of early-discharge initiatives, and barriers to implementation. We received 61 responses from 115 institutions (53% response rate). Forty-seven (77%) "strongly agreed" or "agreed" that early discharge was a priority. "Discharge by noon" was the most cited goal (n = 23; 38%) followed by "no set time but overall goal for improvement" (n = 13; 21%). The majority of respondents reported early discharge as more important than obtaining translators for non-English-speaking patients and equally important as reducing 30-day readmissions and improving patient satisfaction. The most commonly reported factors delaying discharge were availability of postacute care beds (n = 48; 79%) and patient-related transport complications (n = 44; 72%). The most effective early discharge initiatives reported involved changes to the rounding process, such as preemptive identification and early preparation of discharge paperwork (n = 34; 56%) and communication with patients about anticipated discharge (n = 29; 48%). There is a strong interest in increasing early discharges in an effort to improve hospital throughput and patient flow. © 2017 Society of Hospital Medicine.

  9. Soft chemical synthesis and electrochemical properties of calcium ferrite-type LixMn2O4

    NASA Astrophysics Data System (ADS)

    Mamiya, Mikito; Tokiwa, Kazuyasu; Akimoto, Junji

    2016-04-01

    Calcium ferrite (CaFe2O4)-type LixMn2O4 was prepared via high-pressure and soft chemical synthesis method. The framework structure of CaFe2O4-type NaMn2O4 was synthesized from the stoichiometric mixture of Na2CO3 and MnO2 annealed by 1273 K for 1 h under 4.5 GPa. Na/Li ion-exchange of the CaFe2O4-type NaMn2O4 was carried out by soaking molten LiNO3 at 633 K for 12 h. The electrochemical properties of the ion-exchanged CaFe2O4-type LixMn2O4 were measured. The initial discharge profile in the voltage range from 4.0 to 1.0 V showed 458 mAh g-1 of the discharge capacity with two plateaus near 3.7 V and 2.7 V (vs. Li/Li+). The discharge capacity was decreased with increasing the cycle number. After 30 cycles, the capacity was decreased to 375 mAh g-1. When the range was set between 4.8 and 3.0 V, the discharge capacity was 113 mAh g-1 in initial, and 111 mAh g-1 after 50th cycle. The reference CaFe2O4-type LiMn2O4 was prepared via one-step high-pressure synthesis and compared the electrochemical properties with the ion-exchanged sample. The initial discharge capacity of the one-step synthesized one was 108 mAh g-1 at 1.0 V (vs. Li/Li+), which was 73% lower than the value of the ion-exchanged one.

  10. Development summary of a sympathetic discharge CO2 laser for lidar use

    NASA Technical Reports Server (NTRS)

    Jaenisch, Holger M.; Johnson, R. Barry

    1991-01-01

    A commercial pulsed sympathetic discharge laser has been characterized and modified for use as a potential lidar. This report summarizes the initial findings and modifications made to the baseline system. The new laser performance is then checked with theory and operational results are presented. The laser has inherent mode instability and high chirp. Several solutions were tried and their results are presented.

  11. Overview of Initial NSTX-U Experimental Operations

    NASA Astrophysics Data System (ADS)

    Battaglia, Devon; the NSTX-U Team

    2016-10-01

    Initial operation of the National Spherical Torus Experiment Upgrade (NSTX-U) has satisfied a number of commissioning milestones, including demonstration of discharges that exceed the field and pulse length of NSTX. ELMy H-mode operation at the no-wall βN limit is obtained with Boronized wall conditioning. Peak H-mode parameters include: Ip = 1 MA, BT0 = 0.63 T, WMHD = 330 kJ, βN = 4, βN/li = 6, κ = 2.3, τE , tot >50 ms. Access to high-performance H-mode scenarios with long MHD-quiescent periods is enabled by the resilient timing of the L-H transition via feedback control of the diverting time and shape, and correction of the dominant n =1 error fields during the Ip ramp. Stationary L-mode discharges have been realized up to 1 MA with 2 s discharges achieved at Ip = 650 kA. The long-pulse L-mode discharges enabled by the new central solenoid supported initial experiments on error field measurements and correction, plasma shape control, controlled discharge ramp-down, L-mode transport and fast ion physics. Increased off-axis current drive and reduction of fast ion instabilities has been observed with the new, more tangential neutral beamline. The initial results support that access to increased field, current and heating at low-aspect-ratio expands the regimes available to develop scenarios, diagnostics and predictive models that inform the design and optimization of future burning plasma tokamak devices, including ITER. Work Supported by U.S. DOE Contract No. DE-AC02-09CH11466.

  12. Influence of surface emission processes on a fast-pulsed dielectric barrier discharge in air at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Pechereau, François; Bonaventura, Zdeněk; Bourdon, Anne

    2016-08-01

    This paper presents simulations of an atmospheric pressure air discharge in a point-to-plane geometry with a dielectric layer parallel to the cathode plane. Experimentally, a discharge reignition in the air gap below the dielectrics has been observed. With a 2D fluid model, it is shown that due to the fast rise of the high voltage applied and the sharp point used, a first positive spherical discharge forms around the point. Then this discharge propagates axially and impacts the dielectrics. As the first discharge starts spreading on the upper dielectric surface, in the second air gap with a low preionization density of {{10}4}~\\text{c}{{\\text{m}}-3} , the 2D fluid model predicts a rapid reignition of a positive discharge. As in experiments, the discharge reignition is much slower, a discussion on physical processes to be considered in the model to increase the reignition delay is presented. The limit case with no initial seed charges in the second air gap has been studied. First, we have calculated the time to release an electron from the cathode surface by thermionic and field emission processes for a work function φ \\in ≤ft[3,4\\right] eV and an amplification factor β \\in ≤ft[100,220\\right] . Then a 3D Monte Carlo model has been used to follow the dynamics of formation of an avalanche starting from a single electron emitted at the cathode. Due to the high electric field in the second air gap, we have shown that in a few nanoseconds, a Gaussian cloud of seed charges is formed at a small distance from the cathode plane. This Gaussian cloud has been used as the initial condition of the 2D fluid model in the second air gap. In this case, the propagation of a double headed discharge in the second air gap has been observed and the reignition delay is in rather good agreement with experiments.

  13. Towards Stable Lithium-Sulfur Batteries with a Low Self-Discharge Rate: Ion Diffusion Modulation and Anode Protection.

    PubMed

    Xu, Wen-Tao; Peng, Hong-Jie; Huang, Jia-Qi; Zhao, Chen-Zi; Cheng, Xin-Bing; Zhang, Qiang

    2015-09-07

    The self-discharge of a lithium-sulfur cell decreases the shelf-life of the battery and is one of the bottlenecks that hinders its practical applications. New insights into both the internal chemical reactions in a lithium-sulfur system and effective routes to retard self-discharge for highly stable batteries are crucial for the design of lithium-sulfur cells. Herein, a lithium-sulfur cell with a carbon nanotube/sulfur cathode and lithium-metal anode in lithium bis(trifluoromethanesulfonyl)imide/1,3-dioxolane/dimethyl ether electrolyte was selected as the model system to investigate the self-discharge behavior. Both lithium anode passivation and polysulfide anion diffusion suppression strategies are applied to reduce self-discharge of the lithium-sulfur cell. When the lithium-metal anode is protected by a high density passivation layer induced by LiNO3 , a very low shuttle constant of 0.017 h(-1) is achieved. The diffusion of the polysulfides is retarded by an ion-selective separator, and the shuttle constants decreased. The cell with LiNO3 additive maintained a discharge capacity of 97 % (961 mAh g(-1) ) of the initial capacity after 120 days at open circuit, which was around three times higher than the routine cell (32 % of initial capacity, corresponding to 320 mAh g(-1) ). It is expected that lithium-sulfur batteries with ultralow self-discharge rates may be fabricated through a combination of anode passivation and polysulfide shuttle control, as well as optimization of the lithium-sulfur cell configuration. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A descriptive study of urethral discharge among men in Fiji.

    PubMed

    Gaunavinaka, Lavenia; Balak, Dashika; Varman, Sumanthla; Ram, Sharan; Graham, Stephen M

    2014-10-17

    Urethral discharge is a common presentation of sexually transmitted infection (STI) in men and known pathogens include Neisseria gonorrhoeae and Chlamydia trachomatis. There are no published data of the burden of urethral discharge among men in Fiji. To evaluate urethral discharge among men to determine the incidence, the frequency of recurrence and reported at-risk behaviour. We conducted a retrospective, descriptive study of clinical records of all men presenting with urethral discharge to two major reproductive health clinics. Data collected included self-reported at-risk behaviours, results of abnormal syphilis serology and antibiotics prescribed. The frequency of recurrence in the following 1-2 years of initial presentation was determined along with microbiological findings from urethral swab in this group. A total of 748 males presented with urethral discharge to the clinic in one year. This represents an incidence rate of at least 295 per 100,000 adult males per year in the study population. Within the next 1-2 years of the initial presentation, 102 (14%) of these re-presented out of which 42 had urethral swab taken for etiological diagnosis. The commonest isolate was Neisseria gonorrhoeae. Results of syphilis tests were available for 560 (75%) of patients and 29 (5%) were positive. Recurrence was not associated with self-reported at-risk behaviours. The incidence of urethral discharge among males in Fiji is very high and prevention strategies are urgently needed.

  15. Transient groundwater dynamics in a coastal aquifer: The effects of tides, the lunar cycle, and the beach profile

    NASA Astrophysics Data System (ADS)

    Abarca, Elena; Karam, Hanan; Hemond, Harold F.; Harvey, Charles F.

    2013-05-01

    Detailed field measurements are combined with a numerical modeling to characterize the groundwater dynamics beneath the discharge zone at Waquoit Bay, Massachusetts. Groundwater salinity values revealed a saline circulation cell that overlaid the discharging freshwater and grew and disappeared with the lunar cycle. The cell was initiated by a greater bay water infiltration during the new moon when high tides overtopped the mean high-tide mark, flooding the flatter beach berm and inundating a larger area of the beach. The dynamics of this cell were further characterized by a tracer test and by constructing a density-dependent flow model constrained to salinity and head data. The numerical model captured the growing and diminishing behavior of the circulation cell and provided the estimates of freshwater and saline water fluxes and travel times. Furthermore, the model enabled quantification of the relationship between the characteristics of the observed tidal cycle (maximum, minimum, and mean tidal elevations) and the different components of the groundwater circulation (freshwater discharge, intertidal saline cycling, and deep saline cycling). We found that (1) recharge to the intertidal saline cell is largely controlled by the high-tide elevation; (2) freshwater discharge is positively correlated to the low-tide elevation, whereas deep saline discharge from below the discharging freshwater is negatively correlated to the low-tide elevation. So, when the low-tide elevation is relatively high, more freshwater discharges and less deep saltwater discharges. In contrast when low tides are very low, less freshwater discharges and more deep salt water discharges; (3) offshore inflow of saline water is largely insensitive to tides and the lunar cycle.

  16. Note: Measuring breakdown characteristics during the hot re-ignition of high intensity discharge lamps using high frequency alternating current voltage.

    PubMed

    van den Bos, R A J M; Sobota, A; Manders, F; Kroesen, G M W

    2013-04-01

    To investigate the cold and hot re-ignition properties of High Intensity Discharge (HID) lamps in more detail an automated setup was designed in such a way that HID lamps of various sizes and under different background pressures can be tested. The HID lamps are ignited with a ramped sinusoidal voltage signal with frequencies between 60 and 220 kHz and with amplitude up to 7.5 kV. Some initial results of voltage and current measurements on a commercially available HID lamp during hot and cold re-ignition are presented.

  17. An experimental investigation of a hollow cathode discharge

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1971-01-01

    An experimental study of the effects of various modifications to the hollow cathode discharge region of a 20 cm electron bombardment ion thruster is presented. The introduction of electrical insulation between the main and cathode discharge regions is shown to have no significant effect on thruster performance. Adjustment of both the diameter and length of the cathode discharge region from the design condition are examined and the reduced sizes are shown to effect large improvements in propellant utilization when the thruster is operating at about 30% of the design thrust level. Performance improvements are shown to be less significant at higher thrust levels. The feasibility of using a high voltage tickler electrode to initiate the cathode-keeper discharge is considered and results obtained suggest this mode of startup is unsatisfactory.

  18. [Home care for the high-risk newborn infant].

    PubMed

    Puddu, M

    2010-06-01

    With increased survival of extremely low birth weigh (ELBW) and very ill infants, a lot of them are discharged with unresolved medical issues that complicate their subsequent care. Infants born preterm with low birth weight who require neonatal intensive care experience a much higher rate of hospital readmission and death during the first year after birth compared with healthy term infants. Despite initial hospital care which is one of the most expensive of all kind of hospitalization, home care services are sometimes still sparse though the high risk of this group for failure to thrive, respiratory problems, developmental delays, parenting problems. In addition, societal and economic forces have come to bear on the timing and process of discharge and home care. Moreover it takes time for the family of a high-risk infant to prepare to care for their infant in a home setting and to obtain the necessary support services and mobilize community resources. Careful preparation for discharge, good follow-up and medical home after discharge may reduce these risks.

  19. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Study of emission of a volume nanosecond discharge plasma in xenon, krypton and argon at high pressures

    NASA Astrophysics Data System (ADS)

    Baksht, E. Kh; Lomaev, Mikhail I.; Rybka, D. V.; Tarasenko, Viktor F.

    2006-06-01

    The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude—time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ~45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ~130 ns.

  20. [Secondary Splenic Rupture after Initially Inconspicuous CAT Scan].

    PubMed

    Prokop, A; Koll, S; Chmielnicki, M

    2016-04-01

    Splenic injuries occur in 1-5 % of blunt abdominal trauma cases. After initial haemorrhagic compression, secondary delayed spleen rupture can occur with a latency of one day to a month or longer. Mortality is then up to 15 %. The spleen injury is almost always recognisable on CT or ultrasound. In one case from our clinic, secondary splenic rupture occurred in a patient after discharge from hospitalisation, even though the initial CT and ultrasound were unremarkable. The patient survived, and underwent emergent splenectomy 8 days after the trauma. An expert review of the case identified no errors in treatment. No case of secondary splenic rupture after initially unremarkable diagnostic studies and clinical course has previously been published. Secondary splenic rupture has a high mortality rate. Patients should be advised of potential complications after hospital discharge, and should return to the hospital immediately in case of symptoms. Georg Thieme Verlag KG Stuttgart · New York.

  1. A novel two-level dielectric barrier discharge reactor for methyl orange degradation.

    PubMed

    Tao, Xumei; Wang, Guowei; Huang, Liang; Ye, Qingguo; Xu, Dongyan

    2016-12-15

    A novel pilot two-level dielectric barrier discharge (DBD) reactor has been proposed and applied for degradation of continuous model wastewater. The two-level DBD reactor was skillfully realized with high space utilization efficiency and large contact area between plasma and wastewater. Various conditions such as applied voltage, initial concentration and initial pH value on methyl orange (MO) model wastewater degradation were investigated. The results showed that the appropriate applied voltage was 13.4 kV; low initial concentration and low initial pH value were conducive for MO degradation. The percentage removal of 4 L MO with concentration of 80 mg/L reached 94.1% after plasma treatment for 80min. Based on ultraviolet spectrum (UV), Infrared spectrum (IR), liquid chromatography-mass spectrometry (LC-MS) analysis of degradation intermediates and products, insights in the degradation pathway of MO were proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Ecton processes in the generation of pulsed runaway electron beams in a gas discharge

    NASA Astrophysics Data System (ADS)

    Mesyats, G. A.

    2017-09-01

    As was shown earlier for pulsed discharges that occur in electric fields rising with extremely high rates (1018 V/(cm s)) during the pulse rise time, the electron current in a vacuum discharge is lower than the current of runaway electrons in an atmospheric air discharge in a 1-cm-long gap. In this paper, this is explained by that the field emission current from cathode microprotrusions in a gas discharge is enhanced due to gas ionization. This hastens the initiation of explosive electron emission, which occurs within 10-11 s at a current density of up to 1010 A/cm2. Thereafter, a first-type cathode spot starts forming. The temperature of the cathode spot decreases due to heat conduction, and the explosive emission current ceases. Thus, the runaway electron current pulse is similar in nature to the ecton phenomenon in a vacuum discharge.

  3. Performance of a High-Fidelity 4kW-Class Engineering Model PPU and Integration with HiVHAc System

    NASA Technical Reports Server (NTRS)

    Pinero, Luis R.; Kamhawi, Hani; Shilo, Vladislav

    2016-01-01

    The High Voltage Hall Accelerator (HiVHAc) propulsion system consists of a thruster,power processing unit (PPU), and propellant feed system. An engineering model PPU was developed by Colorado Power Electronics, Inc. funded by NASA's Small Business Innovative Research Program. This PPU uses an innovative 3-phase resonant converter to deliver 4 kW of discharge power over a wide range of input and output voltage conditions.The PPU includes a digital control interface unit that automatically controls the PPU and a xenon flow control module (XFCM). It interfaces with a control computer to receive high level commands and relay telemetry through a MIL-STD-1553B interface. The EM PPU was thoroughly tested at GRC for functionality and performance at temperature extremes and demonstrated total efficiencies a high as 95 percent. It was integrated with the HiVHAc thruster and the XFCM to demonstrate closed-loop control of discharge current with anode flow. Initiation of the main discharge and power throttling were also successfully demonstrated and discharge oscillations were characterized.

  4. Initial results from the NASA Lewis Bumpy Torus experiment. [of steady-state ion heating method based on modified Penning discharge

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Richardson, R. W.; Gerdin, G. A.

    1973-01-01

    Initial results were obtained from low power operation of the NASA Lewis Bumpy Torus experiment, in which a steady-state ion heating method based on the modified Penning discharge is applied in a bumpy torus confinement geometry. The magnet facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T, equally spaced in a toroidal array 1.52 m in major diameter. A 18 cm i.d. anode ring is located at each of the 12 midplanes and is maintained at high positive potentials by a dc power supply. Initial observations indicate electron temperatures from 10 to 150 eV, and ion kinetic temperatures from 200 eV to 1200 eV. Two modes of operation were observed, which depend on background pressure, and have different radial density profiles. Steady state neutron production was observed. The ion heating process in the bumpy torus appears to parallel closely the mechanism observed when the modified Penning discharge was operated in a simple magnetic mirror field.

  5. Fast combustion waves and chemi-ionization processes in a flame initiated by a powerful local plasma source in a closed reactor

    PubMed Central

    Artem'ev, K. V.; Berezhetskaya, N. K.; Kazantsev, S. Yu.; Kononov, N. G.; Kossyi, I. A.; Popov, N. A.; Tarasova, N. M.; Filimonova, E. A.; Firsov, K. N.

    2015-01-01

    Results are presented from experimental studies of the initiation of combustion in a stoichiometric methane–oxygen mixture by a freely localized laser spark and by a high-current multispark discharge in a closed chamber. It is shown that, preceding the stage of ‘explosive’ inflammation of a gas mixture, there appear two luminous objects moving away from the initiator along an axis: a relatively fast and uniform wave of ‘incomplete combustion’ under laser spark ignition and a wave with a brightly glowing plasmoid behind under ignition from high-current slipping surface discharge. The gas mixtures in both the ‘preflame’ and developed-flame states are characterized by a high degree of ionization as the result of chemical ionization (plasma density ne≈1012 cm−3) and a high frequency of electron–neutral collisions (νen≈1012 s−1). The role of chemical ionization in constructing an adequate theory for the ignition of a gas mixture is discussed. The feasibility of the microwave heating of both the preflame and developed-flame plasma, supplementary to a chemical energy source, is also discussed. PMID:26170426

  6. Some Factors Affecting the Reproducibility of Penetration and the Cut-Off of Oil Sprays for Fuel-injection Engines

    NASA Technical Reports Server (NTRS)

    Beardsley, E G

    1928-01-01

    This investigation was undertaken at the Langley Memorial Aeronautical Laboratory in connection with a general research on fuel-injection for aircraft. The purpose of the investigation was to determine the factors controlling the reproducibility of spray penetration and secondary discharges after cut-off. The development of single sprays from automatic injection valves was recorded by means of special high-speed photographic apparatus capable of taking 25 consecutive pictures of the moving spray at a rate of 4,000 per second. The effect of two types of injection valves, injection-valve tube length, initial pressure in the injection-valve tube, speed of the injection control mechanism, and time of spray cut-off, on the reproducibility of spray penetration, and on secondary discharges were investigated. It was found that neither type of injection valve materially affected spray reproducibility. The initial pressure in the injection-valve tube controlled the reproducibility of spray penetrations. An increase in the initial pressure or in the length of the injection-valve tube slightly increased the spray penetration within the limits of this investigation. The speed of the injection-control mechanism did not affect the penetration. Analysis of the results indicates that secondary discharges were caused in this apparatus by pressure waves initiated by the rapid opening of the cut-off valve. The secondary discharges were eliminated in this investigation by increasing the length of the injection-valve tube. (author)

  7. Geospatial database of estimates of groundwater discharge to streams in the Upper Colorado River Basin

    USGS Publications Warehouse

    Garcia, Adriana; Masbruch, Melissa D.; Susong, David D.

    2014-01-01

    The U.S. Geological Survey, as part of the Department of the Interior’s WaterSMART (Sustain and Manage America’s Resources for Tomorrow) initiative, compiled published estimates of groundwater discharge to streams in the Upper Colorado River Basin as a geospatial database. For the purpose of this report, groundwater discharge to streams is the baseflow portion of streamflow that includes contributions of groundwater from various flow paths. Reported estimates of groundwater discharge were assigned as attributes to stream reaches derived from the high-resolution National Hydrography Dataset. A total of 235 estimates of groundwater discharge to streams were compiled and included in the dataset. Feature class attributes of the geospatial database include groundwater discharge (acre-feet per year), method of estimation, citation abbreviation, defined reach, and 8-digit hydrologic unit code(s). Baseflow index (BFI) estimates of groundwater discharge were calculated using an existing streamflow characteristics dataset and were included as an attribute in the geospatial database. A comparison of the BFI estimates to the compiled estimates of groundwater discharge found that the BFI estimates were greater than the reported groundwater discharge estimates.

  8. Using the Electronic Medical Record to Enhance Physician-Nurse Communication Regarding Patients' Discharge Status.

    PubMed

    Driscoll, Molly; Gurka, David

    2015-01-01

    The fast-paced environment of hospitals contributes to communication failures between health care providers while impacting patient care and patient flow. An effective mechanism for sharing patients' discharge information with health care team members is required to improve patient throughput. The communication of a patient's discharge plan was identified as crucial in alleviating patient flow delays at a tertiary care, academic medical center. By identifying the patients who were expected to be discharged the following day, the health care team could initiate discharge preparations in advance to improve patient care and patient flow. The patients' electronic medical record served to convey dynamic information regarding the patients' discharge status to the health care team via conditional discharge orders. Two neurosciences units piloted a conditional discharge order initiative. Conditional discharge orders were designed in the electronic medical record so that the conditions for discharge were listed in a dropdown menu. The health care team was trained on the conditional discharge order protocol, including when to write them, how to find them in the patients' electronic medical record, and what actions should be prompted by these orders. On average, 24% of the patients discharged had conditional discharge orders written the day before discharge. The average discharge time for patients with conditional discharge orders decreased by 83 minutes (0.06 day) from baseline. Qualitatively, the health care team reported improved workflows with conditional orders. The conditional discharge orders allowed physicians to communicate pending discharges electronically to the multidisciplinary team. The initiative positively impacted patient discharge times and workflows.

  9. Investigation of the relevant kinetic processes in the initial stage of a double-arcing instability in oxygen plasmas

    NASA Astrophysics Data System (ADS)

    Mancinelli, B.; Prevosto, L.; Chamorro, J. C.; Minotti, F. O.; Kelly, H.

    2018-05-01

    A numerical investigation of the kinetic processes in the initial (nanosecond range) stage of the double-arcing instability was developed. The plasma-sheath boundary region of an oxygen-operated cutting torch was considered. The energy balance and chemistry processes in the discharge were described. It is shown that the double-arcing instability is a sudden transition from a diffuse (glow-like) discharge to a constricted (arc-like) discharge in the plasma-sheath boundary region arising from a field-emission instability. A critical electric field value of ˜107 V/m was found at the cathodic part of the nozzle wall under the conditions considered. The field-emission instability drives in turn a fast electronic-to-translational energy relaxation mechanism, giving rise to a very fast gas heating rate of at least ˜109 K/s, mainly due to reactions of preliminary dissociation of oxygen molecules via the highly excited electronic state O2(B3Σu-) populated by electron impact. It is expected that this fast oxygen heating rate further stimulates the discharge contraction through the thermal instability mechanism.

  10. Local changes in neocortical circuit dynamics coincide with the spread of seizures to thalamus in a model of epilepsy.

    PubMed

    Neubauer, Florian B; Sederberg, Audrey; MacLean, Jason N

    2014-01-01

    During the generalization of epileptic seizures, pathological activity in one brain area recruits distant brain structures into joint synchronous discharges. However, it remains unknown whether specific changes in local circuit activity are related to the aberrant recruitment of anatomically distant structures into epileptiform discharges. Further, it is not known whether aberrant areas recruit or entrain healthy ones into pathological activity. Here we study the dynamics of local circuit activity during the spread of epileptiform discharges in the zero-magnesium in vitro model of epilepsy. We employ high-speed multi-photon imaging in combination with dual whole-cell recordings in acute thalamocortical (TC) slices of the juvenile mouse to characterize the generalization of epileptic activity between neocortex and thalamus. We find that, although both structures are exposed to zero-magnesium, the initial onset of focal epileptiform discharge occurs in cortex. This suggests that local recurrent connectivity that is particularly prevalent in cortex is important for the initiation of seizure activity. Subsequent recruitment of thalamus into joint, generalized discharges is coincident with an increase in the coherence of local cortical circuit activity that itself does not depend on thalamus. Finally, the intensity of population discharges is positively correlated between both brain areas. This suggests that during and after seizure generalization not only the timing but also the amplitude of epileptiform discharges in thalamus is entrained by cortex. Together these results suggest a central role of neocortical activity for the onset and the structure of pathological recruitment of thalamus into joint synchronous epileptiform discharges.

  11. Local changes in neocortical circuit dynamics coincide with the spread of seizures to thalamus in a model of epilepsy

    PubMed Central

    Neubauer, Florian B.; Sederberg, Audrey; MacLean, Jason N.

    2014-01-01

    During the generalization of epileptic seizures, pathological activity in one brain area recruits distant brain structures into joint synchronous discharges. However, it remains unknown whether specific changes in local circuit activity are related to the aberrant recruitment of anatomically distant structures into epileptiform discharges. Further, it is not known whether aberrant areas recruit or entrain healthy ones into pathological activity. Here we study the dynamics of local circuit activity during the spread of epileptiform discharges in the zero-magnesium in vitro model of epilepsy. We employ high-speed multi-photon imaging in combination with dual whole-cell recordings in acute thalamocortical (TC) slices of the juvenile mouse to characterize the generalization of epileptic activity between neocortex and thalamus. We find that, although both structures are exposed to zero-magnesium, the initial onset of focal epileptiform discharge occurs in cortex. This suggests that local recurrent connectivity that is particularly prevalent in cortex is important for the initiation of seizure activity. Subsequent recruitment of thalamus into joint, generalized discharges is coincident with an increase in the coherence of local cortical circuit activity that itself does not depend on thalamus. Finally, the intensity of population discharges is positively correlated between both brain areas. This suggests that during and after seizure generalization not only the timing but also the amplitude of epileptiform discharges in thalamus is entrained by cortex. Together these results suggest a central role of neocortical activity for the onset and the structure of pathological recruitment of thalamus into joint synchronous epileptiform discharges. PMID:25232306

  12. Manual vs. integrated automatic load-distributing band CPR with equal survival after out of hospital cardiac arrest. The randomized CIRC trial.

    PubMed

    Wik, Lars; Olsen, Jan-Aage; Persse, David; Sterz, Fritz; Lozano, Michael; Brouwer, Marc A; Westfall, Mark; Souders, Chris M; Malzer, Reinhard; van Grunsven, Pierre M; Travis, David T; Whitehead, Anne; Herken, Ulrich R; Lerner, E Brooke

    2014-06-01

    To compare integrated automated load distributing band CPR (iA-CPR) with high-quality manual CPR (M-CPR) to determine equivalence, superiority, or inferiority in survival to hospital discharge. Between March 5, 2009 and January 11, 2011 a randomized, unblinded, controlled group sequential trial of adult out-of-hospital cardiac arrests of presumed cardiac origin was conducted at three US and two European sites. After EMS providers initiated manual compressions patients were randomized to receive either iA-CPR or M-CPR. Patient follow-up was until all patients were discharged alive or died. The primary outcome, survival to hospital discharge, was analyzed adjusting for covariates, (age, witnessed arrest, initial cardiac rhythm, enrollment site) and interim analyses. CPR quality and protocol adherence were monitored (CPR fraction) electronically throughout the trial. Of 4753 randomized patients, 522 (11.0%) met post enrollment exclusion criteria. Therefore, 2099 (49.6%) received iA-CPR and 2132 (50.4%) M-CPR. Sustained ROSC (emergency department admittance), 24h survival and hospital discharge (unknown for 12 cases) for iA-CPR compared to M-CPR were 600 (28.6%) vs. 689 (32.3%), 456 (21.8%) vs. 532 (25.0%), 196 (9.4%) vs. 233 (11.0%) patients, respectively. The adjusted odds ratio of survival to hospital discharge for iA-CPR compared to M-CPR, was 1.06 (95% CI 0.83-1.37), meeting the criteria for equivalence. The 20 min CPR fraction was 80.4% for iA-CPR and 80.2% for M-CPR. Compared to high-quality M-CPR, iA-CPR resulted in statistically equivalent survival to hospital discharge. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Death after discharge: predictors of mortality in older brain-injured patients.

    PubMed

    Peck, Kimberly A; Calvo, Richard Y; Sise, C Beth; Johnson, Jeffrey; Yen, Jessica W; Sise, Michael J; Dunne, Casey E; Badiee, Jayraan; Shackford, Steven R; Lobatz, Michael A

    2014-12-01

    Older patients with traumatic brain injury (TBI) may be at high risk of death after hospitalization. The purpose of this study was to characterize long-term mortality of older TBI patients who survived to discharge. We hypothesized that predictors of postdischarge mortality differed from those of inpatient mortality. A retrospective cohort study was performed on TBI patients older than 55 years admitted to our Level I trauma center between July 1, 2006, and December 31, 2011. Postdischarge deaths were identified by matching patient data with local vital records up to December 31, 2011, when data collection was terminated (censoring). Patients were categorized by age, comorbidities, history of preinjury anticoagulant/prescription antiplatelet agent therapy, injury severity indices, initial TBI type, prehospital living status, discharge location, and discharge condition. The effect of risk factors on postdischarge mortality was evaluated by Cox proportional hazards modeling. Of 353 patients, 322 (91.2%) survived to discharge. Postdischarge mortality was 19.8% (n = 63) for the study period. Of the postdischarge deaths, 54.0% died within 6 months of discharge, and 68.3% died within 1 year. Median days to death after discharge or censoring were 149 and 410, respectively. Factors associated with death after discharge included age, preinjury anticoagulant use, higher number of Charlson comorbidities, discharge to a long-term care facility, and severe disability. Factors related to injury severity (i.e., Injury Severity Score [ISS], initial Glasgow Coma Scale [GCS] score) and preinjury prescription antiplatelet agent use, previously found to predict inpatient death, did not predict postdischarge mortality. Older TBI patients who survive to discharge have a significant risk of death within 1 year. Predictors of postdischarge mortality and inpatient death differ. Death after discharge is largely a function of overall health status. Monitoring health status and continued aggressive management of comorbidities after discharge may be essential in determining long-term outcomes. Epidemiologic study, level III.

  14. Trends in Use of High-Intensity Statin Therapy After Myocardial Infarction, 2011 to 2014.

    PubMed

    Rosenson, Robert S; Farkouh, Michael E; Mefford, Matthew; Bittner, Vera; Brown, Todd M; Taylor, Ben; Monda, Keri L; Zhao, Hong; Dai, Yuling; Muntner, Paul

    2017-06-06

    Data prior to 2011 suggest that a low percentage of patients hospitalized for acute coronary syndromes filled high-intensity statin prescriptions upon discharge. Black-box warnings, generic availability of atorvastatin, and updated guidelines may have resulted in a change in high-intensity statin use. The aim of this study was to examine trends and predictors of high-intensity statin use following hospital discharge for myocardial infarction (MI) between 2011 and 2014. Secular trends in high-intensity statin use following hospital discharge for MI were analyzed among patients 19 to 64 years of age with commercial health insurance in the MarketScan database (n = 42,893) and 66 to 75 years of age with U.S. government health insurance through Medicare (n = 75,096). Patients filling statin prescriptions within 30 days of discharge were included. High-intensity statins included atorvastatin 40 or 80 mg and rosuvastatin 20 or 40 mg. The percentage of beneficiaries whose first statin prescriptions filled following hospital discharge for MI were for high-intensity doses increased from 33.5% in January through March 2011 to 71.7% in October through November 2014 in MarketScan and from 24.8% to 57.5% in Medicare. Increases in high-intensity statin use following hospital discharge occurred over this period among patients initiating treatment (30.6% to 72.0% in MarketScan and 21.1% to 58.8% in Medicare) and those taking low- or moderate-intensity statins prior to hospitalization (from 27.8% to 62.3% in MarketScan and from 12.6% to 45.1% in Medicare). In 2014, factors associated with filling high-intensity statin prescriptions included male sex, filling beta-blocker and antiplatelet agent prescriptions, and attending cardiac rehabilitation within 30 days following discharge. The use of high-intensity statins following hospitalization for MI increased progressively from 2011 through 2014. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Design and development of a low cost, high current density power supply for streamer free atmospheric pressure DBD plasma generation in air.

    PubMed

    Jain, Vishal; Visani, Anand; Srinivasan, R; Agarwal, Vivek

    2018-03-01

    This paper presents a new power supply architecture for generating a uniform dielectric barrier discharge (DBD) plasma in air medium at atmospheric pressure. It is quite a challenge to generate atmospheric pressure uniform glow discharge plasma, especially in air. This is because air plasma needs very high voltage for initiation of discharge. If the high voltage is used along with high current density, it leads to the formation of streamers, which is undesirable for most applications like textile treatment, etc. Researchers have tried to generate high-density plasma using a RF source, nanosecond pulsed DC source, and medium frequency AC source. However, these solutions suffer from low current discharge and low efficiency due to the addition of an external resistor to control the discharge current. Moreover, they are relatively costly and bulky. This paper presents a new power supply configuration which is very compact and generates high average density (∼0.28 W/cm 2 ) uniform glow DBD plasma in air at atmospheric pressure. The efficiency is also higher as no external resistor is required to control the discharge current. An inherent feature of this topology is that it can drive higher current oscillations (∼50 A peak and 2-3 MHz frequency) into the plasma that damp out due to the plasma dissipation only. A newly proposed model has been used with experimental validation in this paper. Simulations and experimental validation of the proposed topology are included. Also, the application of the generated plasma for polymer film treatment is demonstrated.

  16. Design and development of a low cost, high current density power supply for streamer free atmospheric pressure DBD plasma generation in air

    NASA Astrophysics Data System (ADS)

    Jain, Vishal; Visani, Anand; Srinivasan, R.; Agarwal, Vivek

    2018-03-01

    This paper presents a new power supply architecture for generating a uniform dielectric barrier discharge (DBD) plasma in air medium at atmospheric pressure. It is quite a challenge to generate atmospheric pressure uniform glow discharge plasma, especially in air. This is because air plasma needs very high voltage for initiation of discharge. If the high voltage is used along with high current density, it leads to the formation of streamers, which is undesirable for most applications like textile treatment, etc. Researchers have tried to generate high-density plasma using a RF source, nanosecond pulsed DC source, and medium frequency AC source. However, these solutions suffer from low current discharge and low efficiency due to the addition of an external resistor to control the discharge current. Moreover, they are relatively costly and bulky. This paper presents a new power supply configuration which is very compact and generates high average density (˜0.28 W/cm2) uniform glow DBD plasma in air at atmospheric pressure. The efficiency is also higher as no external resistor is required to control the discharge current. An inherent feature of this topology is that it can drive higher current oscillations (˜50 A peak and 2-3 MHz frequency) into the plasma that damp out due to the plasma dissipation only. A newly proposed model has been used with experimental validation in this paper. Simulations and experimental validation of the proposed topology are included. Also, the application of the generated plasma for polymer film treatment is demonstrated.

  17. A comparison between initial continuous currents of different types of upward lightning

    NASA Astrophysics Data System (ADS)

    Wang, D.; Sawada, N.; Takagi, N.

    2009-12-01

    We have observed the lightning to a wind turbine and its lightning-protection tower for four consecutive winter seasons from 2005 to 2009. Our observation items include (1) thunderstorm electrical fields and lightning-caused electric field changes at multi sites around the wind turbine, (2) electrical currents at the bottom of the wind turbine and its lightning protection tower, (3) normal video and high speed image of lightning optical channels. Totally, we have obtained the data for 42 lightning that hit either on wind turbine or its lightning protection tower or both. Among these 42 lightning, 38 are upward lightning and 2 are downward lightning. We found the upward lightning can be sub-classified into two types. Type 1 upward lightning are self-triggered from a high structure, while type 2 lightning are triggered by a discharge occurred in other places which could be either a cloud discharge or a cloud-to-ground discharge (other-triggered). In this study, we have compared the two types of upward lightning in terms of initial continuous current rise time, peak current and charge transferred to the ground. We found that the initial current of self-triggered lightning tends to rise significantly faster and to a bigger peak value than the other-triggered lightning, although both types of lightning transferred similar amount of charge to the ground.

  18. Hyperpycnal sediment discharge from semiarid southern California rivers: Implications for coastal sediment budgets

    USGS Publications Warehouse

    Warrick, J.A.; Milliman, John D.

    2003-01-01

    Southern California rivers discharge hyperpycnal (river density greater than ocean density) concentrations of suspended sediment (>40 g/L, according to buoyancy theory) during flood events, mostly during El Nin??o-Southern Oscillation (ENSO) conditions. Because hyperpycnal river discharge commonly occurs during brief periods (hours to occasionally days), mean daily flow statistics often do not reveal the magnitude of these events. Hyperpycnal events are particularly important in rivers draining the Transverse Range and account for 75% of the cumulative sediment load discharged by the Santa Clara River over the past 50 yr. These events are highly pulsed, totaling only ??? 30 days (??? 0.15% of the total 50 yr period). Observations of the fate of sediment discharge, although rare, are consistent with hyperpycnal river dynamics and the high likelihood of turbidity currents during these events. We suggest that much of the sediment load initially bypasses the littoral circulation cells and is directly deposited on the adjacent continental shelf, thus potentially representing a loss of immediate beach sand supply. During particularly exceptional events (>100 yr recurrence intervals), flood underflows may extend past the shelf and escape to offshore basins.

  19. Signal enhancement in laser-induced breakdown spectroscopy using fast square-pulse discharges

    NASA Astrophysics Data System (ADS)

    Sobral, H.; Robledo-Martinez, A.

    2016-10-01

    A fast, high voltage square-shaped electrical pulse initiated by laser ablation was investigated as a means to enhance the analytical capabilities of laser Induced breakdown spectroscopy (LIBS). The electrical pulse is generated by the discharge of a charged coaxial cable into a matching impedance. The pulse duration and the stored charge are determined by the length of the cable. The ablation plasma was produced by hitting an aluminum target with a nanosecond 532-nm Nd:YAG laser beam under variable fluence 1.8-900 J cm- 2. An enhancement of up to one order of magnitude on the emission signal-to-noise ratio can be achieved with the spark discharge assisted laser ablation. Besides, this increment is larger for ionized species than for neutrals. LIBS signal is also increased with the discharge voltage with a tendency to saturate for high laser fluences. Electron density and temperature evolutions were determined from time delays of 100 ns after laser ablation plasma onset. Results suggest that the spark discharge mainly re-excites the laser produced plume.

  20. Evaluation of a community based childhood injury prevention program.

    PubMed Central

    Bablouzian, L.; Freedman, E. S.; Wolski, K. E.; Fried, L. E.

    1997-01-01

    OBJECTIVES: This pilot study evaluates the effectiveness of a community based childhood injury prevention program on the reduction of home hazards. METHODS: High risk pregnant women, who were enrolled in a home visiting program that augments existing health and human services, received initial home safety assessments. Clients received education about injury prevention practices, in addition to receiving selected home safety supplies. Fourteen questions from the initial assessment tool were repeated upon discharge from the program. Matched analyses were conducted to evaluate differences from initial assessment to discharge. RESULTS: A significantly larger proportion of homes were assessed as safe at discharge, compared with the initial assessment, for the following hazards: children riding unbuckled in all auto travel, Massachusetts Poison Center sticker on the telephone, outlet plugs in all unused electrical outlets, safety latches on cabinets and drawers, and syrup of ipecac in the home. CONCLUSIONS: A community based childhood injury prevention program providing education and safety supplies to clients significantly reduced four home hazards for which safety supplies were provided. Education and promotion of the proper use of child restraint systems in automobiles significantly reduced a fifth hazard, children riding unbuckled in auto travel. This program appears to reduce the prevalence of home hazards and, therefore, to increase home safety. PMID:9113841

  1. High-frequency underwater plasma discharge application in antibacterial activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O{sub 2}) injected and hydrogen peroxide (H{sub 2}O{sub 2}) added discharge in water was achieved. The effect of H{sub 2}O{sub 2} dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H{sub 2}O{sub 2} addition with O{sub 2} injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population onmore » the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH{sup •}, H, and O). Interestingly, the results demonstrated that O{sub 2} injected and H{sub 2}O{sub 2} added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.« less

  2. High-frequency underwater plasma discharge application in antibacterial activity

    NASA Astrophysics Data System (ADS)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U.; Mongre, R. K.; Jeong, D. K.; Suresh, R.; Lee, H. J.

    2017-03-01

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli ( E. coli) by generating high-frequency, high-voltage, oxygen (O2) injected and hydrogen peroxide (H2O2) added discharge in water was achieved. The effect of H2O2 dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H2O2 addition with O2 injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH•, H, and O). Interestingly, the results demonstrated that O2 injected and H2O2 added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  3. The Role of Climatic Conditions in Controlling Observed Variability of Timing and Peak Discharge of Glacial Lake Outburst Floods: Lago Cachet Dos, Chile

    NASA Astrophysics Data System (ADS)

    Jacquet, J.; McCoy, S. W.; McGrath, D.; Nimick, D.; Friesen, B.; Fahey, M. J.; Leidich, J.; Okuinghttons, J.

    2016-12-01

    The sudden release of water from an ice-dammed lake poses substantial hazard to the downstream environment, but predicting the timing and magnitude of such an event is difficult. We use a series of high-resolution discharge measurements from a glacier-dammed lake, Lago Cachet Dos (LC2), during outburst events to evaluate the environmental conditions that influence the timing of initiation and peak discharge of observed glacial lake outburst floods (GLOFs). Since April 2008, 20 GLOFs have initiated out of LC2, located on the eastern edge of the Northern Patagonia Icefield, Chile and flooded areas along the Rio Colonia- Rio Baker system. GLOF frequency has averaged 2-3 events annually and peak discharges exiting LC2 have ranged widely from 2,000 to >15,000 m3 s-1. Although some LC2 GLOFs are consistent with global compilations relating peak discharge to lake volume, large deviations from the global trend and large intra-event variability are striking and call into question the predictive ability of simple empirical scaling equations. To evaluate the environmental conditions that lead to variability in observed peak discharge, we use a variation of the theoretical model of Nye (1976), which describes the process of englacial conduit evolution as a competition between thermally induced conduit growth and viscous flow of ice causing conduit collapse. We show that, consistent with theory, initial lake volume, lake temperature, and the rate of meltwater input into the glacially dammed lake all influence the peak discharge of measured GLOFs. Consequently, evolving climatic conditions of a region can greatly influence the potential hazard of GLOFs. Our results suggest that more accurate predictions of GLOF timing and magnitude from ice dammed lakes can be made by incorporating additional measurements of environmental conditions.

  4. Performance of a High-Fidelity 4kW-Class Engineering Model PPU and Integration with HiVHAc System

    NASA Technical Reports Server (NTRS)

    Pinero, Luis R.; Kamhawi, Hani; Shilo, Vlad

    2016-01-01

    The High Voltage Hall Accelerator (HiVHAc) propulsion system consists of a thruster, power processing unit (PPU), and propellant feed system. An engineering model PPU was developed by Colorado Power Electronics, Inc. funded by NASA's Small Business Innovative Research Program. This PPU uses an innovative 3-phase resonant converter to deliver 4 kW of discharge power over a wide range of input and output voltage conditions. The PPU includes a digital control interface unit that automatically controls the PPU and a xenon flow control module (XFCM). It interfaces with a control computer to receive highlevel commands and relay telemetry through a MIL-STD-1553B interface. The EM PPU was thoroughly tested at GRC for functionality and performance at temperature limits and demonstrated total efficiencies a high as 95 percent. Integrated testing of the unit was performed with the HiVHAc thruster and the XFCM to demonstrate closed-loop control of discharge current with anode flow. Initiation of the main discharge and power throttling were also successfully demonstrated and discharge oscillations were characterized.

  5. Effectiveness of a Model Bundle Payment Initiative for Femur Fracture Patients.

    PubMed

    Lott, Ariana; Belayneh, Rebekah; Haglin, Jack; Konda, Sanjit; Egol, Kenneth A

    2018-05-28

    Analyze the effectiveness of a BPCI (Bundle Payments for Care Improvement) initiative for patients who would be included in a future potential Surgical Hip and Femur Fracture Treatment (SHFFT) bundle. Retrospective cohort SETTING:: Single Academic Institution PATIENTS/PARTICIPANTS:: Patients discharged with operative fixation of a hip or femur fracture (DRG codes 480-482) between 1/2015-10/2016 were included. A BPCI initiative based upon an established program for BPCI Total Joint Arthroplasty (TJA) was initiated for patients with hip and femur fractures in January 2016. Patients were divided into non-bundle (care before initiative) and bundle (care with initiative) cohorts. Application of BPCI principles MAIN OUTCOME MEASURES:: Length of stay, location of discharge, readmissions RESULTS:: 116 patients participated in the "institutional bundle," and 126 received care prior to the initiative. There was a trend towards decreased mean length of stay, (7.3 ± 6.3 days vs. 6.8 ± 4.0 days, p=0.457) and decreased readmission within 90 days (22.2% vs. 18.1%, p=0.426). The number of patients discharged home doubled (30.2% vs. 14.3%, p=0.008). There was no difference in readmission rates in bundle vs. non-bundle patients based on discharged home status; however, bundle patients discharged to SNF trended towards less readmissions than non-bundle patients discharged to SNF (37.3% vs. 50.6%, p=0.402). Mean episode cost reduction due to initiative was estimated to be $6,450 using Medicare reimbursement data. This study demonstrates the potential success of a BPCI initiative at one institution in decreasing post-acute care facility utilization and cost of care when used for a hip and femur fracture population. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  6. Modelling Discharge Inception in Thunderstorms

    NASA Astrophysics Data System (ADS)

    Rutjes, C.; Dubinova, A.; Ebert, U.; Buitink, S.; Scholten, O.; Trinh, G. T. N.

    2014-12-01

    The electric fields in thunderstorms can exceed the breakdown value locally near hydrometeors. But are fields high enough and the regions large enough to initiate a streamer discharge? And where would a sufficient density of free electrons come from to start the discharge in the humid air that rapidly binds electrons in water-clusters? To analyse these questions, we investigate the interaction of extensive air showers (created by high energy cosmic particles) with the hydrometeors in a thunderstorm. The extensive air showers are modelled in full detail with CORSIKA (https://web.ikp.kit.edu/corsika/). As extensive air showers are occurring with a frequency that strongly depends on their size, proper stochastics are derived to cope with the large number of random variables in the system, such as: occurrence, primary energy, altitude of first interaction and inclination. These variables are important factors that determine the extremes of the high energy particle flux passing through a hydrometeor at a given altitude. In addition, the interaction of the high energy particle flux with the hydrometeor is modelled with EGS5 (http://rcwww.kek.jp/research/egs/egs5.html). Finally the streamer initiation and evolution is modelled by our 2.5D streamer fluid code that now can include dielectric bodies; here we used the frequency dependent dielectric permittivity of ice, accounting for the fact that ice can not polarise instantaneously.

  7. Conformal spinel/layered heterostructures of Co3O4 shells grown on single-crystal Li-rich nanoplates for high-performance lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Xin, Yue; Lan, Xiwei; Chang, Peng; Huang, Yaqun; Wang, Libin; Hu, Xianluo

    2018-07-01

    Lithium-rich layered materials have received much attention because of their high specific capacity and high energy density. Unfortunately, they suffer from irreversible capacity loss, low initial Coulombic efficiency and poor cyclability. Here we report a facile co-precipitation method to synthesize uniform single-crystal Li-rich Li[Li0.2Mn0.54Ni0.13Co0.13]O2 nanoplates without using any template. Subsequently, a Co3O4 shell is in situ grown on the Li-rich nanoplates through a hydrothermal method, leading to spinel/layered heterostructures. The electrode made of conformal heterostructured Li-rich/Co3O4 nanoplates delivers a high discharge capacity of 296 mA h g-1 at 0.1 C with an initial Coulombic efficiency of 84%. The capacity retention reaches 83.2% with a discharge capacity of 223 mA h g-1 after 160 cycles at 0.2 C during the potential window ranging from 2.0 to 4.8 V. The enhanced electrochemical performance of the resulting Li-rich/Co3O4 nanoplates benefits from the unique conformal heterostructure as well as the electrochemically active LixCoOy generated between the reaction of Co3O4 shells and the extracted Li2O during charging/discharging processes.

  8. Kinetics of charged particles in a high-voltage gas discharge in a nonuniform electrostatic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolpakov, V. A., E-mail: kolpakov683@gmail.com; Krichevskii, S. V.; Markushin, M. A.

    A high-voltage gas discharge is of interest as a possible means of generating directed flows of low-temperature plasma in the off-electrode space distinguished by its original features [1–4]. We propose a model for calculating the trajectories of charges particles in a high-voltage gas discharge in nitrogen at a pressure of 0.15 Torr existing in a nonuniform electrostatic field and the strength of this field. Based on the results of our calculations, we supplement and refine the extensive experimental data concerning the investigation of such a discharge published in [1, 2, 5–8]; good agreement between the theory and experiment has beenmore » achieved. The discharge burning is initiated and maintained through bulk electron-impact ionization and ion–electron emission. We have determined the sizes of the cathode surface regions responsible for these processes, including the sizes of the axial zone involved in the discharge generation. The main effect determining the kinetics of charged particles consists in a sharp decrease in the strength of the field under consideration outside the interelectrode space, which allows a free motion of charges with specific energies and trajectories to be generated in it. The simulation results confirm that complex electrode systems that allow directed plasma flows to be generated at a discharge current of hundreds or thousands of milliamperes and a voltage on the electrodes of 0.3–1 kV can be implemented in practice [3, 9, 10].« less

  9. High-Speed Imaging of the First Kink Mode Instability in a Magnetoplasmadynamic Thruster

    NASA Technical Reports Server (NTRS)

    Walker, Jonathan A.; Langendof, Samuel; Walker, Mitchell L. R.; Polzin, Kurt; Kimberlin, Adam

    2013-01-01

    One of the biggest challenges to efficient magnetoplasmadynamic thruster (MPDT) operation is the onset of high-frequency voltage oscillations as the discharge current is increased above a threshold value. The onset regime is closely related to magnetohydrodynamic instabilities known as kink modes. This work documents direct observation of the formation and quasi-steady state behavior of an argon discharge plasma in a MPDT operating at discharge currents of 8 to 10 kA for a pulse length of approximately 4 ms. A high-speed camera images the quasi-steady-state operation of the thruster at 26,143 fps with a frame exposure time of 10 micro s. A 0.9 neutral density filter and 488-nm argon line filter with a 10-nm bandwidth are used on separate trials to capture the time evolution of the discharge plasma. Frame-by-frame analysis of the power flux incident on the CCD sensor shows both the initial discharge plasma formation process and the steady-state behavior of the discharge plasma. Light intensity levels on the order of 4-6 W/m2 indicate radial and azimuthal asymmetries in the concentration of argon plasma in the discharge channel. The plasma concentration exhibits characteristics that suggest the presence of a helical plasma column. This helical behavior has been observed in previous experiments that characterize plasma kink mode instabilities indirectly. Therefore, the direct imaging of these plasma kink modes further supports the link between MPDT onset behavior and the excitation of the magnetohydrodynamic instabilities.

  10. Multipoint Ignition of a Gas Mixture by a Microwave Subcritical Discharge with an Extended Streamer Structure

    NASA Astrophysics Data System (ADS)

    Aleksandrov, K. V.; Busleev, N. I.; Grachev, L. P.; Esakov, I. I.; Ravaev, A. A.

    2018-02-01

    The results of experimental studies on using an electrical discharge with an extended streamer structure in a quasioptical microwave beam in the multipoint ignition of a propane-air mixture have been reported. The pulsed microwave discharge was initiated at the interior surface of a quartz tube that was filled with the mentioned flammable mixture and introduced into a microwave beam with a subbreakdown initial field. Gas breakdown was initiated by an electromagnetic vibrator. The dependence of the type of discharge on the microwave field strength was examined, the lower concentration threshold of ignition of the propane-air mixture by the studied discharge was determined, and the dynamics of combustion of the flammable mixture with local and multipoint ignition were compared.

  11. High-altitude electrical discharges associated with thunderstorms and lightning

    NASA Astrophysics Data System (ADS)

    Liu, Ningyu; McHarg, Matthew G.; Stenbaek-Nielsen, Hans C.

    2015-12-01

    The purpose of this paper is to introduce electrical discharge phenomena known as transient luminous events above thunderstorms to the lightning protection community. Transient luminous events include the upward electrical discharges from thunderstorms known as starters, jets, and gigantic jets, and electrical discharges initiated in the lower ionosphere such as sprites, halos, and elves. We give an overview of these phenomena with a focus on starters, jets, gigantic jets, and sprites, because similar to ordinary lightning, streamers and leaders are basic components of these four types of transient luminous events. We present a few recent observations to illustrate their main properties and briefly review the theories. The research in transient luminous events has not only advanced our understanding of the effects of thunderstorms and lightning in the middle and upper atmosphere, but also improved our knowledge of basic electrical discharge processes critical for sparks and lightning.

  12. Global helium particle balance in LHD

    NASA Astrophysics Data System (ADS)

    Motojima, G.; Masuzaki, S.; Tokitani, M.; Kasahara, H.; Yoshimura, Y.; Kobayashi, M.; Sakamoto, R.; Morisaki, T.; Miyazawa, J.; Akiyama, T.; Ohno, N.; Mutoh, T.; Yamada, H.; LHD Experiment Group

    2015-08-01

    Global helium particle balance in long-pulse discharges is analyzed for the first time in the Large Helical Device (LHD) with the plasma-facing components of the first wall and the divertor tiles composed of stainless steel and carbon, respectively. During the 2-min discharge sustained by ion cyclotron resonance heating (ICRH) and electron cyclotron heating (ECH), helium is observed to be highly retained in the wall (regarded as both the first wall and the divertor tiles). Almost all (about 96%) puffed helium particles (1.3 × 1022 He) are absorbed in the wall near the end of the discharge. Even though a dynamic retention is eliminated, 56% is still absorbed. The analysis is also applied to longer pulse discharges over 40 min by ICRH and ECH, indicating that the helium wall retention is dynamically changed in time. At the initial phase of the discharge, a mechanism for adsorbing helium other than dynamical retention is invoked.

  13. Rate Dependent Multi-Mechanism Discharge of Ag 0.50VOP 4·1.8H 2O: Insights from In Situ Energy Dispersive X-ray Diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huie, Matthew M.; Bock, David C.; Zhong, Zhong

    Ag 0.50VOPO 4·1.8H 2O (silver vanadium phosphate, SVOP) demonstrates a counterintuitive higher initial loaded voltage under higher discharge current. Energy dispersive X-ray diffraction (EDXRD) from synchrotron radiation was used to create tomographic profiles of cathodes at various depths of discharge for two discharge rates. SVOP displays two reduction mechanisms, reduction of a vanadium center accompanied by lithiation of the structure, or reduction-displacement of a silver cation to form silver metal. In-situ EDXRD provides the opportunity to observe spatially resolved changes to the parent SVOP crystal and formation of Ag 0 during reduction. At a C/170 discharge rate V 5+ reductionmore » is the preferred initial reaction resulting in higher initial loaded voltage. At a discharge rate of C/400 reduction of Ag + with formation of conductive Ag 0 occurs earlier during discharge. Discharge rate also affects the spatial location of reduction products. The faster discharge rate initiates reduction close to the current collector with non-uniform distribution of silver metal resulting in isolated cathode areas. The slower rate develops a more homogenous distribution of reduced SVOP and silver metal. This study illuminates the roles of electronic and ionic conductivity limitations within a cathode at the mesoscale and how they impact the course of reduction processes and loaded voltage.« less

  14. Rate Dependent Multi-Mechanism Discharge of Ag 0.50VOP 4·1.8H 2O: Insights from In Situ Energy Dispersive X-ray Diffraction

    DOE PAGES

    Huie, Matthew M.; Bock, David C.; Zhong, Zhong; ...

    2016-09-01

    Ag 0.50VOPO 4·1.8H 2O (silver vanadium phosphate, SVOP) demonstrates a counterintuitive higher initial loaded voltage under higher discharge current. Energy dispersive X-ray diffraction (EDXRD) from synchrotron radiation was used to create tomographic profiles of cathodes at various depths of discharge for two discharge rates. SVOP displays two reduction mechanisms, reduction of a vanadium center accompanied by lithiation of the structure, or reduction-displacement of a silver cation to form silver metal. In-situ EDXRD provides the opportunity to observe spatially resolved changes to the parent SVOP crystal and formation of Ag 0 during reduction. At a C/170 discharge rate V 5+ reductionmore » is the preferred initial reaction resulting in higher initial loaded voltage. At a discharge rate of C/400 reduction of Ag + with formation of conductive Ag 0 occurs earlier during discharge. Discharge rate also affects the spatial location of reduction products. The faster discharge rate initiates reduction close to the current collector with non-uniform distribution of silver metal resulting in isolated cathode areas. The slower rate develops a more homogenous distribution of reduced SVOP and silver metal. This study illuminates the roles of electronic and ionic conductivity limitations within a cathode at the mesoscale and how they impact the course of reduction processes and loaded voltage.« less

  15. Integration Tests of the 4 kW-class High Voltage Hall Accelerator Power Processing Unit with the HiVHAc and the SPT-140 Hall Effect Thrusters

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Pinero, Luis; Haag, Thomas; Huang, Wensheng; Ahern, Drew; Liang, Ray; Shilo, Vlad

    2016-01-01

    NASAs Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This presentation presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation, open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thrusters discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.

  16. NO Removal with Repetitive Discharges Caused by Reciprocal Traveling Wave Voltage Pulse in a Coaxial Cable

    NASA Astrophysics Data System (ADS)

    Yamaga, Keisuke; Kadowaki, Kazunori; Nishimoto, Sakae; Kitani, Isamu

    This paper describes experimental results of NO removal using barrier discharges produced by a reciprocal pulse generator. When a coaxial cable is charged and then grounded at one end of the cable without any resistance, a reciprocal traveling voltage pulse is repeatedly applied to a barrier-type reactor at the opposite end with a change in its polarity. 50% streamer initiation voltage for the reciprocal pulse generator was much smaller than that with the self-matched pulse generator having a matching resistance. The reason for the low initiation voltage in the reciprocal pulse was that space charges which accumulated on the barrier surface during cable charging had an effect on field enhancement in the reactor after the first polarity reversal. High speed photographs of discharge light produced by the reciprocal pulse showed that the voltage oscillation caused by one switching induced alternate propagation of positive and negative streamers with a very high frequency. In measurements of NO concentration, the reciprocal pulse generator gave a better performance for NO removal ratio than the self-matched pulse generator even though the stored energy in the recipocal pulse generator was very low.

  17. Robust electrodes based on coaxial TiC/C-MnO2 core/shell nanofiber arrays with excellent cycling stability for high-performance supercapacitors.

    PubMed

    Zhang, Xuming; Peng, Xiang; Li, Wan; Li, Limin; Gao, Biao; Wu, Guosong; Huo, Kaifu; Chu, Paul K

    2015-04-17

    A coaxial electrode structure composed of manganese oxide-decorated TiC/C core/shell nanofiber arrays is produced hydrothermally in a KMnO4 solution. The pristine TiC/C core/shell structure prepared on the Ti alloy substrate provides the self-sacrificing carbon shell and highly conductive TiC core, thus greatly simplifying the fabrication process without requiring an additional reduction source and conductive additive. The as-prepared electrode exhibits a high specific capacitance of 645 F g(-1) at a discharging current density of 1 A g(-1) attributable to the highly conductive TiC/C and amorphous MnO2 shell with fast ion diffusion. In the charging/discharging cycling test, the as-prepared electrode shows high stability and 99% capacity retention after 5000 cycles. Although the thermal treatment conducted on the as-prepared electrode decreases the initial capacitance, the electrode undergoes capacitance recovery through structural transformation from the crystalline cluster to layered birnessite type MnO2 nanosheets as a result of dissolution and further electrodeposition in the cycling. 96.5% of the initial capacitance is retained after 1000 cycles at high charging/discharging current density of 25 A g(-1). This study demonstrates a novel scaffold to construct MnO2 based SCs with high specific capacitance as well as excellent mechanical and cycling stability boding well for future design of high-performance MnO2-based SCs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. X-ray computed tomography comparison of individual and parallel assembled commercial lithium iron phosphate batteries at end of life after high rate cycling

    NASA Astrophysics Data System (ADS)

    Carter, Rachel; Huhman, Brett; Love, Corey T.; Zenyuk, Iryna V.

    2018-03-01

    X-ray computed tomography (X-ray CT) across multiple length scales is utilized for the first time to investigate the physical abuse of high C-rate pulsed discharge on cells wired individually and in parallel.. Manufactured lithium iron phosphate cells boasting high rate capability were pulse power tested in both wiring conditions with high discharge currents of 10C for a high number of cycles (up to 1200) until end of life (<80% of initial discharge capacity retained). The parallel assembly reached end of life more rapidly for reasons unknown prior to CT investigations. The investigation revealed evidence of overdischarge in the most degraded cell from the parallel assembly, compared to more traditional failure in the individual cell. The parallel-wired cell exhibited dissolution of copper from the anode current collector and subsequent deposition throughout the separator near the cathode of the cell. This overdischarge-induced copper deposition, notably impossible to confirm with other state of health (SOH) monitoring methods, is diagnosed using CT by rendering the interior current collector without harm or alteration to the active materials. Correlation of CT observations to the electrochemical pulse data from the parallel-wired cells reveals the risk of parallel wiring during high C-rate pulse discharge.

  19. Hydrogen and Ethene Plasma Assisted Ignition by NS discharge at Elevated Temperatures

    NASA Astrophysics Data System (ADS)

    Starikovskiy, Andrey

    2015-09-01

    The kinetics of ignition in lean H2:O2:Ar and C2H4:O2:Ar mixtures has been studied experimentally and numerically after a high-voltage nanosecond discharge. The ignition delay time behind a reflected shock wave was measured with and without the discharge. It was shown that the initiation of the discharge with a specific deposited energy of 10 - 30 mJ/cm3 leads to an order of magnitude decrease in the ignition delay time. Discharge processes and following chain chemical reactions with energy release were simulated. The generation of atoms, radicals and excited and charged particles was numerically simulated using the measured time - resolved discharge current and electric field in the discharge phase. The calculated densities of the active particles were used as input data to simulate plasma-assisted ignition. Good agreement was obtained between the calculated ignition delay times and the experimental data. It follows from the analysis of the calculated results that the main mechanism of the effect of gas discharge on the ignition of hydrocarbons is the electron impact dissociation of O2 molecules in the discharge phase. Detailed kinetic mechanism for plasma assisted ignition of hydrogen and ethene is elaborated and verified.

  20. Semi-idealized modeling of lightning initiation related to vertical air motion and cloud microphysics

    NASA Astrophysics Data System (ADS)

    Wang, Fei; Zhang, Yijun; Zheng, Dong; Xu, Liangtao; Zhang, Wenjuan; Meng, Qing

    2017-10-01

    A three-dimensional charge-discharge numerical model is used, in a semi-idealized mode, to simulate a thunder-storm cell. Characteristics of the graupel microphysics and vertical air motion associated with the lightning initiation are revealed, which could be useful in retrieving charge strength during lightning when no charge-discharge model is available. The results show that the vertical air motion at the lightning initiation sites ( W ini) has a cubic polynomial correlation with the maximum updraft of the storm cell ( W cell-max), with the adjusted regression coefficient R 2 of approximately 0.97. Meanwhile, the graupel mixing ratio at the lightning initiation sites ( q g-ini) has a linear correlation with the maximum graupel mixing ratio of the storm cell ( q g-cell-max) and the initiation height ( z ini), with the coefficients being 0.86 and 0.85, respectively. These linear correlations are more significant during the middle and late stages of lightning activity. A zero-charge zone, namely, the area with very low net charge density between the main positive and negative charge layers, appears above the area of q g-cell-max and below the upper edge of the graupel region, and is found to be an important area for lightning initiation. Inside the zero-charge zone, large electric intensity forms, and the ratio of q ice (ice crystal mixing ratio) to q g (graupel mixing ratio) illustrates an exponential relationship to q g-ini. These relationships provide valuable clues to more accurately locating the high-risk area of lightning initiation in thunderstorms when only dual-polarization radar data or outputs from numerical models without charging/discharging schemes are available. The results can also help understand the environmental conditions at lightning initiation sites.

  1. An all-solid-state metal hydride - Sulfur lithium-ion battery

    NASA Astrophysics Data System (ADS)

    López-Aranguren, Pedro; Berti, Nicola; Dao, Anh Ha; Zhang, Junxian; Cuevas, Fermín; Latroche, Michel; Jordy, Christian

    2017-07-01

    A metal hydride is used for the first time as anode in a complete all-solid-state battery with sulfur as cathode and LiBH4 as solid electrolyte. The hydride is a nanocomposite made of MgH2 and TiH2 counterparts. The battery exhibits a high reversible capacity of 910 mAh g-1 with discharge plateaus at 1.8 V and 1.4 V. Moreover, the capacity remains to 85% of the initial value over the 25 first charge/discharge cycles.

  2. Transient nature of Arctic spring systems driven by subglacial meltwater

    NASA Astrophysics Data System (ADS)

    Scheidegger, J. M.; Bense, V. F.; Grasby, S. E.

    2012-06-01

    In the High Arctic, supra- and proglacial springs occur at Borup Fiord Pass, Ellesmere Island. Spring waters are sulfur bearing and isotope analysis suggests springs are fed by deeply circulating glacial meltwater. However, the mechanism maintaining spring flow is unclear in these areas of thick permafrost which would hamper the discharge of deep groundwater to the surface. It has been hypothesized that fracture zones along faults focus groundwater which discharges initially underneath wet-based parts of the ice. With thinning ice, the spring head is exposed to surface temperatures, tens of degrees lower than temperatures of pressure melting, and permafrost starts to develop. Numerical modeling of coupled heat and fluid flow suggest that focused groundwater discharge should eventually be cut off by permafrost encroaching into the feeding channel of the spring. Nevertheless, our model simulations show that these springs can remain flowing for millennia depending on the initial flow rate and ambient surface temperature. These systems might provide a terrestrial analog for the possible occurrence of Martian springs recharged by polar ice caps.

  3. Pragmatic approach to chest pain patients discharged with undetectable high-sensitivity troponin T and normal electrocardiogram: the STABS + CT protocol.

    PubMed

    Bishop, Warrick; Girao, Gary

    2017-06-01

    A strategy that discharges chest pain patients with negative high-sensitivity troponin and non-ischaemic electrocardiography changes may still result in 0.44% of patients experiencing myocardial infarction within 30 days. We observed that a pragmatic approach that systematically discharged 25 patients on cardio-protective medications of aspirin, metoprolol and atorvastatin followed with prompt (<10 days) coronary computed tomography angiography resulted in no major adverse cardiac event and adverse drug reaction 30 days post-presentation. The strategy resulted in three patients (12%) ultimately diagnosed with likely unstable angina, which required planned coronary intervention in two patients and medical management in one patient. No unplanned readmissions for chest pains were noted from initial presentation through to 6-month follow up. © 2017 Royal Australasian College of Physicians.

  4. The Influence of the Shape of Model Hydrometeors on the Formation of Discharge between an Artificial-Thunderstorm Cell and the Ground

    NASA Astrophysics Data System (ADS)

    Temnikov, A. G.; Chernenskii, L. L.; Orlov, A. V.; Lysov, N. Yu.; Belova, O. S.; Gerastenok, T. K.; Zhuravkova, D. S.

    2017-12-01

    We have experimentally studied how arrays of model coarse hydrometeors influence the initiation and propagation of discharge between an artificial-thunderstorm cell of negative or positive polarity and the ground. It is established for the first time that the probability of initiation and stimulation of a channeled discharge between negatively or positively charged cloud and the ground significantly depends on the shape and size of coarse hydrometeors occurring near the thunderstorm cell boundaries. The obtained results can be used in developing methods for the artificial initiation of the cloud-ground type lightning of both polarities and targeted discharge of thunderstorm clouds.

  5. Experimental investigation on the effect of plasma jet in the triggered discharge process of a gas switch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tie, W., E-mail: twh.110.666@163.com, E-mail: 84470220@qq.com; Xi'an Jiaotong University, Xi'an 710049; Liu, S.

    The temporal and spatial evolution of a plasma jet generated by a spark discharge was observed. The electron temperature and density were obtained under different time and gas pressures by optical emission spectroscopy. Moreover, the discharge process of the plasma-jet triggered gas switch was recorded and analyzed at the lowest working coefficient. The results showed that the plasma jet moved forward in a bullet mode, and the advancing velocity increased with the decrease of pressure, and decreased with time growing. At initial time, the maximum velocity of a plasma jet could reach 3.68 × 10{sup 6 }cm/s. The electron temperature decreased from 2.0 eVmore » to 1.3 eV, and the electron density increased from 3.1 × 10{sup 15}/cm{sup 3} to 6.3 × 10{sup 15}/cm{sup 3} at the initial moment as the gas pressure increases from 0.1 MPa to 0.32 MPa. For a two-gap gas switch, the discharge performances were more depended on the second discharge spark gap (gap 2). Because plasma jet promoted the discharge in Gap 2, the gas switch operating in mode II had better triggered discharge characteristics. In the discharge process, the plasma-jet triggering had the effect of non-penetrating inducing, which not only provided initial electrons for reducing statistical lag but also enhanced the local electric field. The discharge was initiated and accelerated from electron avalanche to streamer. Therefore, a fast discharge was occurred in the gas switch.« less

  6. Psychiatric Discharge Process

    PubMed Central

    Alghzawi, Hamzah M.

    2012-01-01

    Background. Integration of research evidence into clinical nursing practice is essential for the delivery of high-quality nursing care. Discharge planning is an essential process in psychiatric nursing field, in order to prevent recurrent readmission to psychiatric units. Objective. The purpose of this paper is to perform literature overview on psychiatric discharge planning, in order to develop evidence-based practice guideline of psychiatric discharge plan. Methods. A search of electronic databases was conducted. The search process aimed to locate different levels of evidence. Inclusion criteria were studies including outcomes related to prevention of readmission as stability in the community, studies investigating the discharge planning process in acute psychiatric wards, and studies that included factors that impede discharge planning and factors that aid timely discharge. On the other hand, exclusion criteria were studies in which discharge planning was discussed as part of a multi faceted intervention and was not the main focus of the review. Result. Studies met inclusion criteria were mainly literature reviews, consensus statements, and descriptive studies. All of these studies are considered at the lower levels of evidence. Conclusion. This review demonstrated that discharge planning based on general principles (evidence based principles) should be applied during psychiatric discharge planning to make this discharge more effective. Depending on this review, it could be concluded that effective discharge planning includes main three stages; initial discharge meeting, regular discharge meeting(s), and leaving from hospital and discharge day. Each stage of them has requirements should be accomplished be go to the next stage. PMID:23762767

  7. Underwater spark discharge with long transmission line for cleaning horizontal wells

    NASA Astrophysics Data System (ADS)

    Lee, Kern; Chung, Kyoung-Jae; Hwang, Y. S.; Kim, C. Y.

    2017-06-01

    A transmission line is discussed for application in an underwater spark-discharge technique in the cleaning of a horizontal well by incorporating a power-transmission model into the simulation. The pulsed-spark-discharge technique has been proposed for clogged-well rehabilitation, because it removes incrustations that are attached to well screens by using strong pressure waves that are generated by the rapid expansion of a spark channel. To apply the pulsed-spark-discharge technique to the cleaning of horizontal wells, the coaxial cable between the pulsed power supply and the spark gap as a load needs to be extended to a few hundred meters. Prior to field application, pulsed-spark-discharge experiments were conducted and the role of the transmission line was examined using an improved simulation model. In the model, a non-linear interaction of the spark channel and the capacitor bank is described by the pulse-forming action of the coaxial cable. Based on the accurate physical properties of the water plasma, such as the equation of state and electrical conductivity within the region of interest, the amount of energy contributed to the development of a shock wave was evaluated. The simulation shows that if the initial conditions of the spark channel are the same, no further reduction in strength of the pressure wave occurs, even if the cable length is increased above 50 m. Hence, the degraded peak pressure that was observed in the experiments using the longer cable is attributed to a change in the initial condition of the spark channel. The parametric study suggests that the low initial charging voltage, the high ambient water pressure, and the long cable length yield the low initial spark-channel density, which results in a reduced peak pressure. The simulation of line charging is presented to discuss the principle of disturbing the pre-breakdown process by an extended cable.

  8. Discharge pulse phenomenology

    NASA Technical Reports Server (NTRS)

    Frederickson, A. R.

    1985-01-01

    A model was developed which places radiation induced discharge pulse results into a unified conceptual framework. Only two phenomena are required to interpret all space and laboratory results: (1) radiation produces large electrostatic fields inside insulators via the trapping of a net space charge density; and (2) the electrostatic fields initiate discharge streamer plasmas similar to those investigated in high voltage electrical insulation materials; these streamer plasmas generate the pulsing phenomena. The apparent variability and diversity of results seen is an inherent feature of the plasma streamer mechanism acting in the electric fields which is created by irradiation of the dielectrics. The implications of the model are extensive and lead to constraints over what can be done about spacecraft pulsing.

  9. Initial Development of an Exploding Aerosol Can Simulator

    DOT National Transportation Integrated Search

    1998-04-01

    A device was constructed to simulate an exploding aerosol can. The device consisted of a cylindrical pressure vessel for storage of flammable propellants and base product and a high-rate discharge (HRD) valve for quick release of the constituents. Si...

  10. Advanced Concepts Research Initiative

    EPA Science Inventory

    This initiative is investigating various approaches to controlling and treating wet-weather flow (WWF) discharges in the urban watershed. WWF, including combined sewer overflow (CSO), sanitary sewer overflow (SSO) and stormwater discharges are leading causes of receiving water q...

  11. Ab initio structure search and in situ 7Li NMR studies of discharge products in the Li–S battery system

    DOE PAGES

    See, Kimberly A.; Leskes, Michal; Griffin, John M.; ...

    2014-11-10

    The high theoretical gravimetric capacity of the Li–S battery system makes it an attractive candidate for numerous energy storage applications. In practice, cell performance is plagued by low practical capacity and poor cycling. In an effort to explore the mechanism of the discharge with the goal of better understanding performance, we examine the Li–S phase diagram using computational techniques and complement this with an in situ 7Li NMR study of the cell during discharge. Both the computational and experimental studies are consistent with the suggestion that the only solid product formed in the cell is Li 2S, formed soon aftermore » cell discharge is initiated. In situ NMR spectroscopy also allows the direct observation of soluble Li +-species during cell discharge; species that are known to be highly detrimental to capacity retention. We suggest that during the first discharge plateau, S is reduced to soluble polysulfide species concurrently with the formation of a solid component (Li 2S) which forms near the beginning of the first plateau, in the cell configuration studied here. The NMR data suggest that the second plateau is defined by the reduction of the residual soluble species to solid product (Li 2S). Lastly, a ternary diagram is presented to rationalize the phases observed with NMR during the discharge pathway and provide thermodynamic underpinnings for the shape of the discharge profile as a function of cell composition.« less

  12. Individualized follow up programme and early discharge in term neonates.

    PubMed

    De Carolis, Maria Pia; Cocca, Carmen; Valente, Elisabetta; Lacerenza, Serafina; Rubortone, Serena Antonia; Zuppa, Antonio Alberto; Romagnoli, Costantino

    2014-07-15

    Early discharge of mother/neonate dyad has become a common practice, and its effects are measured by readmission rates. We evaluated the safety of early discharge followed by an individualized Follow-up programme and the efficacy in promoting breastfeeding initiation and duration. During a nine-month period early discharge followed by an early targeted Follow-up was carried out in term neonates in the absence of weight loss <10% or hyperbilirubinaemia at risk of treatment. Follow-up visits were performed at different timepoints with a specific flow-chart according to both bilirubin levels and weight loss at discharge. During the study period early discharge was performed in 419 neonates and Follow-up was carried out in 408 neonates (97.4%). No neonates required readmission for hyperbilirubinaemia and dehydration during the first 28 days of life. Breastfeeding rate was 90.6%, 75.2%, 41.5% at 30, 90 and 180 days of life, respectively. A six-month phone interview was performed for 383 neonates (93.8%) and satisfaction of parents about early discharge was high in 345 cases (90.1%). Early discharge in association with an individualized Follow-up programme resulted safe for the neonate and effective for breastfeeding initation and duration.

  13. Laser-guided, intersecting discharge channels for the final beam transport in heavy-ion fusion

    NASA Astrophysics Data System (ADS)

    Niemann, C.; Neff, S.; Tauschwitz, A.; Penache, D.; Birkner, R.; Constantin, C.; Knobloch, R.; Presura, R.; Rosmej, F. B.; Hoffmann, D. H. H.; Yu, S. S.

    2003-06-01

    Ion-beam transport in space charge neutralizing discharge channels has been proposed for the final focus and chamber transport in a heavy-ion fusion reactor. A driver scenario with two-sided target illumination requires a system of two intersecting discharges to transport beams of the same charge from opposite sides towards the fusion target. In this article we report on experiments on the creation of free-standing, intersecting high-current discharge channels. The discharges are initiated in ammonia gas (NH3) in a metallic chamber by two perpendicular CO2-laser beams, which resonantly heat and subsequently rarefy the gas along the laser paths before the breakdown. These low density channels guide the discharges along the predefined paths and also around the 90° angles without any mechanical guiding structures. In this way stable X-, T-, and L-shaped discharges with currents in excess of 40 kA, at pressures of a few mbar were created with a total length of 110 cm. An 11.4 A MeV 58Ni+12 beam from the UNILAC (Universal Linear Accelerator) linear accelerator was used to probe the line-integrated ion-optical properties of the central channel in a T-shaped discharge.

  14. Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges

    NASA Astrophysics Data System (ADS)

    P. Sarrette, J.; Eichwald, O.; Marchal, F.; Ducasse, O.; Yousfi, M.

    2016-05-01

    The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics, chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post-discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.

  15. Synthesis of oxide and nitride ceramics in high-power gyrotron discharge

    NASA Astrophysics Data System (ADS)

    Akhmadullina, N. S.; Skvortsova, N. N.; Obraztsova, E. A.; Stepakhin, V. D.; Konchekov, E. M.; Kargin, Yu F.; Shishilov, O. N.

    2017-12-01

    Synthesis of oxides, nitrides, and oxynitrides of silicon and aluminium by a pulsed microwave discharge in the mixtures of metal and dielectric powders is described. The microwave pulses were generated by high-power gyrotron (frequency 75 GHz, power up to 550 kW, pulse duration from 0.1 to 15ms). SiO2 + β-Si3N4 (1:1 by molar) and α-Al2O3 + AlN (2:1 by molar) mixtures with Mg (1 and 5wt%) were treated in air with microwave pulses with power of 250÷400 kW and duration of 2÷8 ms. It was found that the discharge cannot be initiated for both mixtures in absence of Mg at any pulse power and duration. When 1% of Mg was added, the discharge was observed for both mixtures under 8 ms pulses of 400 kW; however, the amounts of materials produced were not enough for analysis. With 5% of Mg the discharge was observed for both mixtures under 8 ms pulses of 350 kW, and products of the plasma-chemical processes in the Al2O3 + AlN mixture were analyzed.

  16. A Multidisciplinary Quality Improvement Approach Increases Breastmilk Availability at Discharge from the Neonatal Intensive Care Unit for the Very-Low-Birth-Weight Infant.

    PubMed

    Bixby, Christine; Baker-Fox, Cindy; Deming, Crystal; Dhar, Vijay; Steele, Caroline

    2016-03-01

    Mothers of very-low-birth-weight (VLBW) infants often struggle to establish and maintain a milk supply. Children's Hospital of Orange County (CHOC Children's) data from 2005 to 2011 showed that while the total percentage of all neonatal intensive care unit (NICU) babies being discharged on breastmilk had remained stable, the percentage of VLBW babies with breastmilk at discharge had declined. This information resulted in a quality improvement initiative to remove barriers and implement programs shown to have the greatest impact on initiating and sustaining lactation in this patient subset. The objective of this initiative was to increase breastmilk availability at discharge for the VLBW population. A multidisciplinary program was initiated, which included NICU parent and staff education, clarification of roles, and improved access to pumping supplies. Physicians and nurses completed online education. An algorithm defining roles in lactation support was developed, and a resource team of trained bedside nurses was formed. Lactation consultant time was then refocused on the VLBW population. In addition, "Lactation Support" was added to the physician daily documentation to bring the topic to daily bedside rounds. Twice weekly lactation rounds between the lactation consultant and neonatologist addressed lactation concerns for each dyad. To address pumping issues, the loaner pump program was enhanced. To assess the effectiveness of the initiative, breastmilk availability at discharge for the VLBW population at CHOC Children's was compared from baseline (2011) to the end of June 2015. VLBW breastmilk availability at discharge upon project initiation was 58.7% and increased by 36% to a final rate of 80% by 2013--a rate sustained through the first 6 months of 2015. The results of this initiative suggest that a multidisciplinary approach, including education, changes in workflow, and redefinition of roles, is effective in improving breastmilk rates at discharge in the VLBW patient population.

  17. Improving Human Milk and Breastfeeding Practices in the NICU.

    PubMed

    Fugate, Karen; Hernandez, Ivonne; Ashmeade, Terri; Miladinovic, Branko; Spatz, Diane L

    2015-01-01

    To determine if systematic implementation of the Spatz Ten Steps for Promoting and Protecting Breastfeeding for Vulnerable Infants (Ten Steps) would result in an improvement in the percentage of infants receiving mother's own milk (MOM) at initiation of feedings and at hospital discharge. Continuous quality improvement (QI) process. Urban, 82-bed, Level-III NICU. Very- low-birth-weight (VLBW) infants weighing fewer than 1500 grams. The Ten Step method was implemented during a 3-year period. Process measurements included percentage of VLBW infants receiving MOM at initiation of feeds, number of mothers of VLBW infants with hospital-grade electric breast pump at hospital discharge, and number of mothers of VLBW infants initiating pumping within 6 hours of delivery. Outcome measurements included percentage of VLBW infants with any human milk at discharge to home and parent satisfaction with nurses' support of mother's efforts to breastfeed. Balancing measurements included percentage of VLBW infants at less than the third percentile for growth on the Fenton growth chart at discharge and receiving pasteurized donor milk (PDM). Significant improvements were achieved in the percentages of mothers expressing their milk within 6 hours of delivery, infants receiving MOM at initiation of feeds, and mothers with a hospital-grade pump at discharge. Improvements in these processes resulted in increased parent satisfaction with nurses' support of breastfeeding and a 3.1-fold greater odds of the VLBW infant receiving MOM at discharge in 2013 compared to 2010 (odds ratio [OR]= 3.01, 95% confidence interval [CI] [1.75, 5.17], p < .001). Despite an increase in the use of MOM, there was not a significant increase in VLBW infants discharged at less than the third percentile for growth, and initiation of PDM did not negatively affect the percentage of VLBW infants with any human milk at discharge. Implementation of the Ten Steps method using QI methodology resulted in significantly improved rates of use of MOM at initiation of feeds and at hospital discharge. © 2015 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.

  18. Implementing wait-time reductions under Ontario government benchmarks (Pay-for-Results): a Cluster Randomized Trial of the Effect of a Physician-Nurse Supplementary Triage Assistance team (MDRNSTAT) on emergency department patient wait times.

    PubMed

    Cheng, Ivy; Lee, Jacques; Mittmann, Nicole; Tyberg, Jeffrey; Ramagnano, Sharon; Kiss, Alex; Schull, Michael; Kerr, Fergus; Zwarenstein, Merrick

    2013-11-11

    Internationally, emergency departments are struggling with crowding and its associated morbidity, mortality, and decreased patient and health-care worker satisfaction. The objective was to evaluate the addition of a MDRNSTAT (Physician (MD)-Nurse (RN) Supplementary Team At Triage) on emergency department patient flow and quality of care. Pragmatic cluster randomized trial. From 131 weekday shifts (8:00-14:30) during a 26-week period, we randomized 65 days (3173 visits) to the intervention cluster with a MDRNSTAT presence, and 66 days (3163 visits) to the nurse-only triage control cluster. The primary outcome was emergency department length-of-stay (EDLOS) for patients managed and discharged only by the emergency department. Secondary outcomes included EDLOS for patients initially seen by the emergency department, and subsequently consulted and admitted, patients reaching government-mandated thresholds, time to initial physician assessment, left-without being seen rate, time to investigation, and measurement of harm. The intervention's median EDLOS for discharged, non-consulted, high acuity patients was 4:05 [95th% CI: 3:58 to 4:15] versus 4:29 [95th% CI: 4:19-4:38] during comparator shifts. The intervention's median EDLOS for discharged, non-consulted, low acuity patients was 1:55 [95th% CI: 1:48 to 2:05] versus 2:08 [95th% CI: 2:02-2:14]. The intervention's median physician initial assessment time was 0:55 [95th% CI: 0:53 to 0:58] versus 1:21 [95th% CI: 1:18 to 1:25]. The intervention's left-without-being-seen rate was 1.5% versus 2.2% for the control (p = 0.06). The MDRNSTAT subgroup analysis resulted in significant decreases in median EDLOS for discharged, non-consulted high (4:01 [95th% CI: 3:43-4:16]) and low acuity patients (1:10 95th% CI: 0:58-1:19]), as well as physician initial assessment time (0:25 [95th% CI: 0:23-0:26]). No patients returned to the emergency department after being discharged by the MDRNSTAT at triage. The intervention reduced delays and left-without-being-seen rate without increased return visits or jeopardizing urgent care of severely ill patients. NCT00991471 ClinicalTrials.gov.

  19. Bedform response to flow variability

    USGS Publications Warehouse

    Nelson, J.M.; Logan, B.L.; Kinzel, P.J.; Shimizu, Y.; Giri, S.; Shreve, R.L.; McLean, S.R.

    2011-01-01

    Laboratory observations and computational results for the response of bedform fields to rapid variations in discharge are compared and discussed. The simple case considered here begins with a relatively low discharge over a flat bed on which bedforms are initiated, followed by a short high-flow period with double the original discharge, during which the morphology of the bedforms adjusts, followed in turn by a relatively long period of the original low discharge. For the grain size and hydraulic conditions selected, the Froude number remains subcritical during the experiment, and sediment moves predominantly as bedload. Observations show rapid development of quasi-two-dimensional bedforms during the initial period of low flow with increasing wavelength and height over the initial low-flow period. When the flow increases, the bedforms rapidly increase in wavelength and height, as expected from other empirical results. When the flow decreases back to the original discharge, the height of the bedforms quickly decreases in response, but the wavelength decreases much more slowly. Computational results using an unsteady two-dimensional flow model coupled to a disequilibrium bedload transport model for the same conditions simulate the formation and initial growth of the bedforms fairly accurately and also predict an increase in dimensions during the high-flow period. However, the computational model predicts a much slower rate of wavelength increase, and also performs less accurately during the final low-flow period, where the wavelength remains essentially constant, rather than decreasing. In addition, the numerical results show less variability in bedform wavelength and height than the measured values; the bedform shape is also somewhat different. Based on observations, these discrepancies may result from the simplified model for sediment particle step lengths used in the computational approach. Experiments show that the particle step length varies spatially and temporally over the bedforms during the evolution process. Assuming a constant value for the step length neglects the role of flow alterations in the bedload sediment-transport process, which appears to result in predicted bedform wavelength changes smaller than those observed. However, observations also suggest that three-dimensional effects play at least some role in the decrease of bedform wavelength, so incorporating better models for particle hop lengths alone may not be sufficient to improve model predictions. ?? 2011 John Wiley & Sons, Ltd.

  20. Application of Artificial Thunderstorm Cells for the Investigation of Lightning Initiation Problems between a Thundercloud and the Ground

    NASA Astrophysics Data System (ADS)

    Temnikov, A. G.; Chernensky, L. L.; Orlov, A. V.; Lysov, N. Y.; Zhuravkova, D. S.; Belova, O. S.; Gerastenok, T. K.

    2017-12-01

    The results of the experimental application of artificial thunderstorm cells of negative and positive polarities for the investigation of the lightning initiation problems between the thundercloud and the ground using model hydrometeor arrays are presented. Possible options of the initiation and development of a discharge between the charged cloud and the ground in the presence of model hydrometeors are established. It is experimentally shown that groups of large hydrometeors of various shapes significantly increase the probability of channel discharge initiation between the artificial thunderstorm cell and the ground, especially in the case of positive polarity of the cloud. The authors assume that large hail arrays in the thundercloud can initiate the preliminary breakdown stage in the lower part of the thundercloud or initiate and stimulate the propagation of positive lightning from its upper part. A significant effect of the shape of model hydrometeors and the way they are grouped on the processes of initiation and stimulation of the channel discharge propagation in the artificial thunderstorm cell of negative or positive polarity-ground gap is experimentally established. It is found that, in the case of negative polarity of a charged cloud, the group of conductive cylindrical hydrometeors connected by a dielectric string more effectively initiates the channel discharge between the artificial thunderstorm cell and the ground. In the case of positive polarity of the artificial thunderstorm cell, the best effect of the channel discharge initiation is achieved for model hydrometeors grouped together by the dielectric tape. The obtained results can be used in the development of the method for the directed artificial lightning initiation between the thundercloud and the ground.

  1. Coupling fine particle and bedload transport in gravel-bedded streams

    NASA Astrophysics Data System (ADS)

    Park, Jungsu; Hunt, James R.

    2017-09-01

    Fine particles in the silt- and clay-size range are important determinants of surface water quality. Since fine particle loading rates are not unique functions of stream discharge this limits the utility of the available models for water quality assessment. Data from 38 minimally developed watersheds within the United States Geological Survey stream gauging network in California, USA reveal three lines of evidence that fine particle release is coupled with bedload transport. First, there is a transition in fine particle loading rate as a function of discharge for gravel-bedded sediments that does not appear when the sediment bed is composed of sand, cobbles, boulders, or bedrock. Second, the discharge at the transition in the loading rate is correlated with the initiation of gravel mobilization. Third, high frequency particle concentration and discharge data are dominated by clockwise hysteresis where rising limb discharges generally have higher concentrations than falling limb discharges. These three observations across multiple watersheds lead to a conceptual model that fine particles accumulate within the sediment bed at discharges less than the transition and then the gravel bed fluidizes with fine particle release at discharges above the transition discharge. While these observations were individually recognized in the literature, this analysis provides a consistent conceptual model based on the coupling of fine particle dynamics with filtration at low discharges and gravel bed fluidization at higher discharges.

  2. Micro-Spherical Sulfur/Graphene Oxide Composite via Spray Drying for High Performance Lithium Sulfur Batteries.

    PubMed

    Tian, Yuan; Sun, Zhenghao; Zhang, Yongguang; Wang, Xin; Bakenov, Zhumabay; Yin, Fuxing

    2018-01-18

    An efficient, industry-accepted spray drying method was used to synthesize micro-spherical sulfur/graphene oxide (S/GO) composites as cathode materials within lithium sulfur batteries. The as-designed wrapping of the sulfur-nanoparticles, with wrinkled GO composites, was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The unique morphological design of this material enabled superior discharge capacity and cycling performance, demonstrating a high initial discharge capacity of 1400 mAh g -1 at 0.1 C. The discharge capacity remained at 828 mAh g -1 after 150 cycles. The superior electrochemical performance indicates that the S/GO composite improves electrical conductivity and alleviates the shuttle effect. This study represents the first time such a facile spray drying method has been adopted for lithium sulfur batteries and used in the fabrication of S/GO composites.

  3. Micro-Spherical Sulfur/Graphene Oxide Composite via Spray Drying for High Performance Lithium Sulfur Batteries

    PubMed Central

    Tian, Yuan; Sun, Zhenghao; Zhang, Yongguang; Yin, Fuxing

    2018-01-01

    An efficient, industry-accepted spray drying method was used to synthesize micro-spherical sulfur/graphene oxide (S/GO) composites as cathode materials within lithium sulfur batteries. The as-designed wrapping of the sulfur-nanoparticles, with wrinkled GO composites, was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The unique morphological design of this material enabled superior discharge capacity and cycling performance, demonstrating a high initial discharge capacity of 1400 mAh g−1 at 0.1 C. The discharge capacity remained at 828 mAh g−1 after 150 cycles. The superior electrochemical performance indicates that the S/GO composite improves electrical conductivity and alleviates the shuttle effect. This study represents the first time such a facile spray drying method has been adopted for lithium sulfur batteries and used in the fabrication of S/GO composites. PMID:29346303

  4. Particle-in-cell modeling of the nanosecond field emission driven discharge in pressurized hydrogen

    NASA Astrophysics Data System (ADS)

    Levko, Dmitry; Yatom, Shurik; Krasik, Yakov E.

    2018-02-01

    The high-voltage field-emission driven nanosecond discharge in pressurized hydrogen is studied using the one-dimensional Particle-in-Cell Monte Carlo collision model. It is obtained that the main part of the field-emitted electrons becomes runaway in the thin cathode sheath. These runaway electrons propagate the entire cathode-anode gap, creating rather dense (˜1012 cm-3) seeding plasma electrons. In addition, these electrons initiate a streamer propagating through this background plasma with a speed ˜30% of the speed of light. Such a high streamer speed allows the self-acceleration mechanism of runaway electrons present between the streamer head and the anode to be realized. As a consequence, the energy of runaway electrons exceeds the cathode-anode gap voltage. In addition, the influence of the field emission switching-off time is analyzed. It is obtained that this time significantly influences the discharge dynamics.

  5. Hierarchical LiMn2O4 Hollow Cubes with Exposed {111} Planes as High-Power Cathodes for Lithium-Ion Batteries.

    PubMed

    Wu, Yu; Cao, Chuanbao; Zhang, Junting; Wang, Lin; Ma, Xilan; Xu, Xingyan

    2016-08-03

    Hierarchical LiMn2O4 hollow cubes with exposed {111} planes have been synthesized using cube-shaped MnCO3 precursors, which are fabricated through a facile co-precipitation reaction. Without surface modification, the as-prepared LiMn2O4 exhibits excellent cyclability and superior rate capability. Surprisingly, even over 70% of primal discharge capacity can be maintained for up to 1000 cycles at 50 C, and with only about 72 s of discharge time the as-prepared materials can deliver initial discharge capacity of 96.5 mA h g(-1). What is more, the materials have 98.4% and 90.7% capacity retentions for up to 100 cycles at 5 C under the temperatures of 25 and 60 °C, respectively. The superior electrochemical performance can be attributed to the unique hierarchical and interior hollow structure, exposed {111} planes, and high-quality crystallinity.

  6. Corona discharges from a windmill and its lightning protection tower in winter thunderstorms

    NASA Astrophysics Data System (ADS)

    Wu, Ting; Wang, Daohong; Rison, William; Thomas, Ronald J.; Edens, Harald E.; Takagi, Nobuyuki; Krehbiel, Paul R.

    2017-05-01

    This paper presents lightning mapping array (LMA) observations of corona discharges from a windmill and its lightning protection tower in winter thunderstorms in Japan. Corona discharges from the windmill, called windmill coronas, and those from the tower, called tower coronas, are distinctly different. Windmill coronas occur with periodic bursts, generally radiate larger power, and possibly develop to higher altitudes than tower coronas do. A strong negative electric field is necessary for the frequent production of tower coronas but is not apparently related with windmill coronas. These differences are due to the periodic rotation of the windmill and the moving blades which can escape space charges produced by corona discharges and sustain a large local electric field. The production period of windmill coronas is related with the rotation period of the windmill. Surprisingly, for one rotation of the windmill, only two out of the three blades produce detectable discharges and source powers of discharges from these two blades are different. The reason for this phenomenon is still unclear. For tower coronas, the source rate can get very high only when there is a strong negative electric field, and the source power can get very high only when the source rate is very low. The relationship between corona discharges and lightning flashes is investigated. There is no direct evidence that corona discharges can increase the chance of upward leader initiation, but nearby lightning flashes can increase the source rate of corona discharges right after the flashes. The peak of the source height distribution of corona discharges is about 100 m higher than the top of the windmill and the top of the tower. Possible reasons for this result are discussed.

  7. An Excitatory Loop with Astrocytes Contributes to Drive Neurons to Seizure Threshold

    PubMed Central

    Chiavegato, Angela; Zonta, Micaela; Cammarota, Mario; Brondi, Marco; Vetri, Francesco; Uva, Laura; Pozzan, Tullio; de Curtis, Marco; Ratto, Gian Michele; Carmignoto, Giorgio

    2010-01-01

    Seizures in focal epilepsies are sustained by a highly synchronous neuronal discharge that arises at restricted brain sites and subsequently spreads to large portions of the brain. Despite intense experimental research in this field, the earlier cellular events that initiate and sustain a focal seizure are still not well defined. Their identification is central to understand the pathophysiology of focal epilepsies and to develop new pharmacological therapies for drug-resistant forms of epilepsy. The prominent involvement of astrocytes in ictogenesis was recently proposed. We test here whether a cooperation between astrocytes and neurons is a prerequisite to support ictal (seizure-like) and interictal epileptiform events. Simultaneous patch-clamp recording and Ca2+ imaging techniques were performed in a new in vitro model of focal seizures induced by local applications of N-methyl-D-aspartic acid (NMDA) in rat entorhinal cortex slices. We found that a Ca2+ elevation in astrocytes correlates with both the initial development and the maintenance of a focal, seizure-like discharge. A delayed astrocyte activation during ictal discharges was also observed in other models (including the whole in vitro isolated guinea pig brain) in which the site of generation of seizure activity cannot be precisely monitored. In contrast, interictal discharges were not associated with Ca2+ changes in astrocytes. Selective inhibition or stimulation of astrocyte Ca2+ signalling blocked or enhanced, respectively, ictal discharges, but did not affect interictal discharge generation. Our data reveal that neurons engage astrocytes in a recurrent excitatory loop (possibly involving gliotransmission) that promotes seizure ignition and sustains the ictal discharge. This neuron–astrocyte interaction may represent a novel target to develop effective therapeutic strategies to control seizures. PMID:20405049

  8. 77 FR 11785 - Energy Conservation Program: Public Meeting and Availability of the Framework Document for High...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ... Conservation Program: Public Meeting and Availability of the Framework Document for High-Intensity Discharge...) is initiating the rulemaking and data collection process to consider establishing energy conservation... Policy and Conservation Act (EPCA) (42 U.S.C. 6291, et seq.; EPCA or ``the Act'') sets forth a variety of...

  9. Improving the reliability of verbal communication between primary care physicians and pediatric hospitalists at hospital discharge.

    PubMed

    Mussman, Grant M; Vossmeyer, Michael T; Brady, Patrick W; Warrick, Denise M; Simmons, Jeffrey M; White, Christine M

    2015-09-01

    Timely and reliable verbal communication between hospitalists and primary care physicians (PCPs) is critical for prevention of medical adverse events but difficult in practice. Our aim was to increase the proportion of completed verbal handoffs from on-call residents or attendings to PCPs within 24 hours of patient discharge from a hospital medicine service to ≥90% within 18 months. A multidisciplinary team collaborated to redesign the process by which PCPs were contacted following patient discharge. Interventions focused on the key drivers of obtaining stakeholder buy-in, standardization of the communication process, including assigning primary responsibility for discharge communication to a single resident on each team and batching calls during times of maximum resident availability, reliable automated process initiation through leveraging the electronic health record (EHR), and transparency of data. A run chart assessed the impact of interventions over time. The percentage of calls initiated within 24 hours of discharge improved from 52% to 97%, and the percentage of calls completed improved to 93%. Results were sustained for 18 months. Standardization of the communication process through hospital telephone operators, use of the discharge order to ensure initiation of discharge communication, and batching of phone calls were associated with improvements in our measures. Reliable verbal discharge communication can be achieved through the use of a standardized discharge communication process coupled with the EHR. © 2015 Society of Hospital Medicine.

  10. Effect of actuating voltage and discharge gap on plasma assisted detonation initiation process

    NASA Astrophysics Data System (ADS)

    Siyin, ZHOU; Xueke, CHE; Wansheng, NIE; Di, WANG

    2018-06-01

    The influence of actuating voltage and discharge gap on plasma assisted detonation initiation by alternating current dielectric barrier discharge was studied in detail. A loose coupling method was used to simulate the detonation initiation process of a hydrogen–oxygen mixture in a detonation tube under different actuating voltage amplitudes and discharge gap sizes. Both the discharge products and the detonation forming process assisted by the plasma were analyzed. It was found that the patterns of the temporal and spatial distributions of discharge products in one cycle keep unchanged as changing the two discharge operating parameters. However, the adoption of a higher actuating voltage leads to a higher active species concentration within the discharge zone, and atom H is the most sensitive to the variations of the actuating voltage amplitude among the given species. Adopting a larger discharge gap results in a lower concentration of the active species, and all species have the same sensitivity to the variations of the gap. With respect to the reaction flow of the detonation tube, the corresponding deflagration to detonation transition (DDT) time and distance become slightly longer when a higher actuating voltage is chosen. The acceleration effect of plasma is more prominent with a smaller discharge gap, and the benefit builds gradually throughout the DDT process. Generally, these two control parameters have little effect on the amplitude of the flow field parameters, and they do not alter the combustion degree within the reaction zone.

  11. Integration Tests of the 4 kW-Class High Voltage Hall Accelerator Power Processing Unit with the HiVHAc and the SPT-140 Hall Effect Thrusters

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Pinero, Luis; Haag, Thomas; Huang, Wensheng; Ahern, Drew; Liang, Ray; Shilo, Vlad

    2016-01-01

    NASA's Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This paper presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation along with open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thruster's discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.

  12. Television Image of a Large Upward Electrical Discharge Above a Thunderstorm System

    NASA Astrophysics Data System (ADS)

    Franz, R. C.; Nemzek, R. J.; Winckler, J. R.

    1990-07-01

    An image of an unusual luminous electrical discharge over a thunderstorm 250 kilometers from the observing site has been obtained with a low-light-level television camera. The discharge began at the cloud tops at 14 kilometers and extended into the clear air 20 kilometers higher. The image, which had a duration of less than 30 milliseconds, resembled two jets or fountains and was probably caused by two localized electric charge concentrations at the cloud tops. Large upward discharges may create a hazard for aircraft and rocket launches and, by penetrating into the ionosphere, may initiate whistler waves and other effects on a magnetospheric scale. Such upward electrical discharges may account for unexplained photometric observations of distant lightning events that showed a low rise rate of the luminous pulse and no electromagnetic sferic pulse of the type that accompanies cloud-to-earth lightning strokes. An unusually high rate of such photometric events was recorded during the night of 22 to 23 September 1989 during a storm associated with hurricane Hugo.

  13. Television image of a large upward electrical discharge above a thunderstorm system.

    PubMed

    Franz, R C; Nemzek, R J; Winckler, J R

    1990-07-06

    An image of an unusual luminous electrical discharge over a thunderstorm 250 kilometers from the observing site has been obtained with a low-light-level television camera. The discharge began at the cloud tops at 14 kilometers and extended into the clear air 20 kilometers higher. The image, which had a duration of less than 30 milliseconds,resembled two jets or fountains and was probably caused by two localizd electric charge concentrations at the cloud tops. Large upward discharges may create a hazard for aircraft and rocket launches and, by penetrating into the ionosphere, may initiate whistler waves and other effects on a magnetospheric scale. Such upward electrical discharges may account for unexplained photometric observations of distant lightning events that showed a low rise rate of the luminous pulse and no electromagnetic sferic pulse of the type that accompanies cloud-to-earth lightning strokes. An unusually high rate of such photometric events was recorded during the night of 22 to 23 September 1989 during a storm associated with hurricane Hugo.

  14. An investigation of manganese based electrode materials for use in lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Sengupta, Surajit

    Lithium-based batteries are potential candidates to provide maximum volumetric and gravimetric energy density. One of the most attractive candidates as a cathode material for secondary lithium ion battery systems is the spinel LiMn 2O4 because it is environmentally friendly, less expensive and is capable of providing high energy density as compared to other cathode materials that are currently available. One problem associated with the spinel structure is capacity fading during multiple cycles of charge and discharge operations. This behaviour is due in part to the structural distortion during deep charge and discharge where nearly 100% of the lithium is extracted and inserted inside the spinel structure. Capacity fading can also be caused by dissolution of manganese ions in the electrolyte phase. A solution based method has been adapted for the synthesis of lithium manganese oxide, and chromium and cobalt doped mixed oxide materials using polyvinyl alcohol (PVA) as a chelating agent. It has been found from TGA/DSC analysis that at around 220°C the synthesis reaction is completed. The precursor powders obtained were annealed at different temperatures and times in the range of 250°C to 600°C and from 2 to 8 hours respectively to obtain pure spinel oxides. From X-ray analysis it has been observed that the crystallite size can be controlled in the range of approximately 6 nm to 32 nm depending on the annealing time and the temperature. The morphology of the synthesized materials consisted of submicron sized particles agglomerated with micropores inside the network structure. To observe the effect of physical properties on battery performance cyclic chronopotentiometric evaluation was conducted. It has been found with these synthesized materials that there is an increase in the 1st discharge capacity with an increase in the annealing time and the temperature at both 1C and C/5 rates. This increase is more significant when the annealing temperature is 600°C as compared to that at 250°C. This implies that an increase in particle size may improve the initial discharge capacity. It was observed that at the discharge rate of 1C, the material annealed at 600°C for 8 hours showed the best performance with respect to an average initial discharge capacity, energy density and capacity retention. However, it was found that the initial discharge capacity, the energy density and the capacity retention are poor for highly crystalline, micron sized lithium manganese oxide cathode material. (Abstract shortened by UMI.)

  15. 42 CFR 412.4 - Discharges and transfers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...

  16. 42 CFR 412.4 - Discharges and transfers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...

  17. 42 CFR 412.4 - Discharges and transfers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...

  18. 42 CFR 412.4 - Discharges and transfers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...

  19. 42 CFR 412.4 - Discharges and transfers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...

  20. Microelectrode-assisted low-voltage atmospheric pressure glow discharge in air

    NASA Astrophysics Data System (ADS)

    Liu, Wenzheng; Zhao, Shuai; Niu, Jiangqi; Chai, Maolin

    2017-09-01

    During the process of discharge, appropriately changing the paths corresponding to electric field lines and the field strength distribution along these paths, as well as increasing the number of initial electrons, can effectively enhance the uniformity of discharge and inhibit the formation of filamentary discharge. A method is proposed that uses a microelectrode to initiate the macroscopic discharge phenomenon. An asymmetric structure was designed comprising a single electrode of carbon fiber; this electrode structure is of helical-contact type. Benefitting from the special electric field distribution and the microdischarge process, a three-dimensional atmospheric pressure glow discharge was achieved in air, characterized by low discharge voltage, low energy consumption, good diffusion performance, and less ozone generation. The plasma studied is uniform and stable with good diffusion characteristics and low levels of contaminants and hence has potential applications in the field of air purification.

  1. Evaluation of data obtained from military disability medical administrative databases for service members with schizophrenia or bipolar disorder.

    PubMed

    Millikan, Amy M; Weber, Natalya S; Niebuhr, David W; Torrey, E Fuller; Cowan, David N; Li, Yuanzhang; Kaminski, Brenda

    2007-10-01

    We are studying associations between selected biomarkers and schizophrenia or bipolar disorder among military personnel. To assess potential diagnostic misclassification and to estimate the date of illness onset, we reviewed medical records for a subset of cases. Two psychiatrists independently reviewed 182 service medical records retrieved from the Department of Veterans Affairs. Data were evaluated for diagnostic concordance between database diagnoses and reviewers. Interreviewer variability was measured by using proportion of agreement and the kappa statistic. Data were abstracted to estimate date of onset. High levels of agreement existed between database diagnoses and reviewers (proportion, 94.7%; kappa = 0.88) and between reviewers (proportion, 92.3%; kappa = 0.87). The median time between illness onset and initiation of medical discharge was 1.6 and 1.1 years for schizophrenia and bipolar disorder, respectively. High levels of agreement between investigators and database diagnoses indicate that diagnostic misclassification is unlikely. Discharge procedure initiation date provides a suitable surrogate for disease onset.

  2. Study on the characteristics of a two gap capillary discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, D.; Yang, L. J., E-mail: yanglj@mail.xjtu.edu.cn; Huo, P.

    2015-02-15

    The paper presents a new two-gap capillary (TGC) discharge structure. The prominent innovation is the introduction of the middle electrode, which divides the capillary into the trigger gap and the main gap. The discharge circuit of the TGC comprises the trigger circuit and the main circuit. The two circuits are used for the pre-ionization of the trigger gap and providing energy of 450 J for the main gap arc discharging, respectively. When the discharge initiates, the trigger gap is pre-ionized under high voltage pulse produced by trigger circuit, and meanwhile, the weakly ionized plasma is generated. The main circuit then maintainsmore » the expansion of the plasma, which is called soft capillary discharge. Afterwards, the main gap is shorted and discharges under a relatively low voltage. With the optimization of the circuit parameter, both the energy deposition ratio in main gap and the degree of plasma ionization are enhanced. The efficiency of the energy deposition is almost twice higher compared with that of the conventional capillary structure. The life performance test indicates that the erosion of the middle electrode and the trigger gap carbonization are the key factors that limit the life performance of the TGC.« less

  3. Research on laser detonation pulse circuit with low-power based on super capacitor

    NASA Astrophysics Data System (ADS)

    Wang, Hao-yu; Hong, Jin; He, Aifeng; Jing, Bo; Cao, Chun-qiang; Ma, Yue; Chu, En-yi; Hu, Ya-dong

    2018-03-01

    According to the demand of laser initiating device miniaturization and low power consumption of weapon system, research on the low power pulse laser detonation circuit with super capacitor. Established a dynamic model of laser output based on super capacitance storage capacity, discharge voltage and programmable output pulse width. The output performance of the super capacitor under different energy storage capacity and discharge voltage is obtained by simulation. The experimental test system was set up, and the laser diode of low power pulsed laser detonation circuit was tested and the laser output waveform of laser diode in different energy storage capacity and discharge voltage was collected. Experiments show that low power pulse laser detonation based on super capacitor energy storage circuit discharge with high efficiency, good transient performance, for a low power consumption requirement, for laser detonation system and low power consumption and provide reference light miniaturization of engineering practice.

  4. Volcano seismicity and ground deformation unveil the gravity-driven magma discharge dynamics of a volcanic eruption.

    PubMed

    Ripepe, Maurizio; Donne, Dario Delle; Genco, Riccardo; Maggio, Giuseppe; Pistolesi, Marco; Marchetti, Emanuele; Lacanna, Giorgio; Ulivieri, Giacomo; Poggi, Pasquale

    2015-05-18

    Effusive eruptions are explained as the mechanism by which volcanoes restore the equilibrium perturbed by magma rising in a chamber deep in the crust. Seismic, ground deformation and topographic measurements are compared with effusion rate during the 2007 Stromboli eruption, drawing an eruptive scenario that shifts our attention from the interior of the crust to the surface. The eruption is modelled as a gravity-driven drainage of magma stored in the volcanic edifice with a minor contribution of magma supplied at a steady rate from a deep reservoir. Here we show that the discharge rate can be predicted by the contraction of the volcano edifice and that the very-long-period seismicity migrates downwards, tracking the residual volume of magma in the shallow reservoir. Gravity-driven magma discharge dynamics explain the initially high discharge rates observed during eruptive crises and greatly influence our ability to predict the evolution of effusive eruptions.

  5. Modification of the Steel Surface Treated by a Volume Discharge Plasma in Nitrogen at Atmospheric Pressure

    NASA Astrophysics Data System (ADS)

    Erofeev, M. V.; Shulepov, M. A.; Ivanov, Yu. F.; Oskomov, K. V.; Tarasenko, V. F.

    2016-03-01

    Effect of volume discharge plasma initiated by an avalanche electron beam on the composition, structure, and properties of the surface steel layer is investigated. Voltage pulses with incident wave amplitude up to 30 kV, full width at half maximum of about 4 ns, and wave front of about 2.5 ns were applied to the gap with an inhomogeneous electric field. Changes indicating the hardening effect of the volume discharge initiated by an avalanche electron beam are revealed in St3-grade steel specimens treated by the discharge of this type.

  6. High-voltage electrode optimization towards uniform surface treatment by a pulsed volume discharge

    NASA Astrophysics Data System (ADS)

    Ponomarev, A. V.; Pedos, M. S.; Scherbinin, S. V.; Mamontov, Y. I.; Ponomarev, S. V.

    2015-11-01

    In this study, the shape and material of the high-voltage electrode of an atmospheric pressure plasma generation system were optimised. The research was performed with the goal of achieving maximum uniformity of plasma treatment of the surface of the low-voltage electrode with a diameter of 100 mm. In order to generate low-temperature plasma with the volume of roughly 1 cubic decimetre, a pulsed volume discharge was used initiated with a corona discharge. The uniformity of the plasma in the region of the low-voltage electrode was assessed using a system for measuring the distribution of discharge current density. The system's low-voltage electrode - collector - was a disc of 100 mm in diameter, the conducting surface of which was divided into 64 radially located segments of equal surface area. The current at each segment was registered by a high-speed measuring system controlled by an ARM™-based 32-bit microcontroller. To facilitate the interpretation of results obtained, a computer program was developed to visualise the results. The program provides a 3D image of the current density distribution on the surface of the low-voltage electrode. Based on the results obtained an optimum shape for a high-voltage electrode was determined. Uniformity of the distribution of discharge current density in relation to distance between electrodes was studied. It was proven that the level of non-uniformity of current density distribution depends on the size of the gap between electrodes. Experiments indicated that it is advantageous to use graphite felt VGN-6 (Russian abbreviation) as the material of the high-voltage electrode's emitting surface.

  7. Numerical studies of wall–plasma interactions and ionization phenomena in an ablative pulsed plasma thruster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Lei; School of Astronautics, Beihang University, Beijing 100191; Zeng, Guangshang

    2016-07-15

    Wall–plasma interactions excited by ablation controlled arcs are very critical physical processes in pulsed plasma thrusters (PPTs). Their effects on the ionization processes of ablated vapor into discharge plasma directly determine PPT performances. To reveal the physics governing the ionization phenomena in PPT discharge, a modified model taking into account the pyrolysis effect of heated polytetrafluoroethylene propellant on the wall–plasma interactions was developed. The feasibility of the modified model was analyzed by creating a one-dimensional simulation of a rectangular ablative PPT. The wall–plasma interaction results based on this modified model were found to be more realistic than for the unmodifiedmore » model; this reflects the dynamic changes of the inflow parameters during discharge in our model. Furthermore, the temporal and spatial variations of the different plasma species in the discharge chamber were numerically studied. The numerical studies showed that polytetrafluoroethylene plasma was mainly composed of monovalent ions; carbon and fluorine ions were concentrated in the upstream and downstream discharge chamber, respectively. The results based on this modified model were in good agreement with the experimental formation times of the various plasma species. A large number of short-lived and highly ionized carbon and fluorine species (divalent and trivalent ions) were created during initial discharge. These highly ionized species reached their peak density earlier than the singly ionized species.« less

  8. Fall Risk, Supports and Services, and Falls Following a Nursing Home Discharge.

    PubMed

    Noureldin, Marwa; Hass, Zachary; Abrahamson, Kathleen; Arling, Greg

    2017-09-04

    Falls are a major source of morbidity and mortality among older adults; however, little is known regarding fall occurrence during a nursing home (NH) to community transition. This study sought to examine whether the presence of supports and services impacts the relationship between fall-related risk factors and fall occurrence post NH discharge. Participants in the Minnesota Return to Community Initiative who were assisted in achieving a community discharge (N = 1459) comprised the study sample. The main outcome was fall occurrence within 30 days of discharge. Factor analyses were used to estimate latent models from variables of interest. A structural equation model (SEM) was estimated to determine the relationship between the emerging latent variables and falls. Fifteen percent of participants fell within 30 days of NH discharge. Factor analysis of fall-related risk factors produced three latent variables: fall concerns/history; activities of daily living impairments; and use of high-risk medications. A supports/services latent variable also emerged that included caregiver support frequency, medication management assistance, durable medical equipment use, discharge location, and receipt of home health or skilled nursing services. In the SEM model, high-risk medications use and fall concerns/history had direct positive effects on falling. Receiving supports/services did not affect falling directly; however, it reduced the effect of high-risk medication use on falling (p < .05). Within the context of a state-implemented transition program, findings highlight the importance of supports/services in mitigating against medication-related risk of falling post NH discharge. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Effect of turbulent flow on an atmospheric-pressure AC powered gliding arc discharge

    NASA Astrophysics Data System (ADS)

    Kong, Chengdong; Gao, Jinlong; Zhu, Jiajian; Ehn, Andreas; Aldén, Marcus; Li, Zhongshan

    2018-06-01

    A high-power gliding arc (GA) discharge was generated in a turbulent air flow driven by a 35 kHz alternating current electric power supply. The effects of the flow rate on the characteristics of the GA discharge were investigated using combined optical and electrical diagnostics. Phenomenologically, the GA discharge exhibits two types of discharge, i.e., glow type and spark type, depending on the flow rates and input powers. The glow-type discharge, which has peak currents of hundreds of milliamperes, is sustained at low flow rates. The spark-type discharge, which is characterized by a sharp current spike of several amperes with duration of less than 1 μs, occurs more frequently as the flow rate increases. Higher input power can suppress spark-type discharges in moderate turbulence, but this effect becomes weak under high turbulent conditions. Physically, the transition between glow- and spark-type is initiated by the short cutting events and the local re-ignition events. Short cutting events occur owing to the twisting, wrinkling, and stretching of the plasma columns that are governed by the relatively large vortexes in the flow. Local re-ignition events, which are defined as re-ignition along plasma columns, are detected in strong turbulence due to increment of the impedance of the plasma column and consequently the internal electric field strength. It is suggested that the vortexes with length scales smaller than the size of the plasma can penetrate into the plasma column and promote mixing with surroundings to accelerate the energy dissipation. Therefore, the turbulent flow influences the GA discharges by ruling the short cutting events with relatively large vortexes and the local re-ignition events with small vortexes.

  10. Theoretical Investigations of Dielectric Breakdown in CO2: Implications for Atmospheric Discharges on Mars (and Venus)

    NASA Astrophysics Data System (ADS)

    Riousset, J. A.

    2017-12-01

    The detection of an atmospheric discharge in the Martian atmosphere by Ruf et al. [GRL, 36, L13202, 2009] supports the idea of a Martian atmospheric electric circuit [Farrell and Desch, JGR, 106, E4, 2001]. However, the lack of subsequent detection of similar events raises the question of the conditions of their initiation, and the existence of Martian lightning remains a controversial question. On Earth, atmospheric electricity manifests itself in the form of glow, corona, streamer, and leader discharges observed as Saint Elmo's fire, sprites, lightning and jets discharges, and other Transient Luminous Events (TLEs). All of these are dielectric breakdown governed by different physics. Their initiation is associated with the crossing of specific electric field thresholds: relativistic runaway, streamer propagation, conventional breakdown, or thermal runaway thresholds, some better understood than others. For example, the initiation of a lightning discharge is known to occur when the local electric field exceeds a value similar to relativistic runaway field, but the exact threshold, as well as the physical mechanisms at work, remain unclear to date. Scaling laws for electric fields (and other quantities) have been established by Pasko et al. [GRL, 25(12), 2123-2126, 1998] and Pasko [NATO Sci. Series, Springer, 253-311, 2006]. In this work, we develop profiles for initiation criteria in air and in other atmospheric environments. We further calculate their associated scaling laws to determine the ability to trigger lightning flashes and TLEs on Mars. This lets us predict the likelihood of electrical discharges and calculate the expected electric field conditions, under which discharges could be observed. We develop the analogy between Earth sand storm [Nicoll et al., Env. Res. Lett., 6, 014001, 2001] and Martian dust storms [Melnik and Parrot, JGR, 103(A12), 1998] to investigate the charge structure and resulting electric fields necessary to initiate dielectric breakdown in the Martian atmosphere. Initiation of electric discharges will be susceptible to local pressure, density, atmospheric composition, and charge structure, and will impact charge moment variations detectable by remote sensing.

  11. Implementation of a clinical pharmacy specialist-managed telephonic hospital discharge follow-up program in a patient-centered medical home.

    PubMed

    Anderson, Sarah L; Marrs, Joel C; Vande Griend, Joseph P; Hanratty, Rebecca

    2013-08-01

    The objectives of this retrospective study were to examine the feasibility and characteristics that define successful implementation of a Clinical Pharmacy Specialist (CPS) telephonic hospital discharge follow-up quality improvement initiative, as well as the impact of this initiative. Adult patients who were discharged from a safety-net hospital between July 1, 2010 and June 30, 2011 and who were part of a patient-centered medical home were included in this quality improvement initiative. CPSs attempted to contact 470 patients; of those, 207 received the intervention and 263 did not. Patients in the contacted group were more likely to attend a hospital discharge follow-up appointment (66.2% vs. 44.5%, P<0.01) and had lower rates of 30-day readmission (22 vs. 52, P<0.01) compared to those who were not contacted. Institutions should consider allocating resources for pharmacist-managed posthospital discharge follow-up services because of the potential for positive clinical and financial impact.

  12. Guiding of High Laser Intensities in Long Plasma Channels

    NASA Astrophysics Data System (ADS)

    Levin, M.; Eisenmann, S.; Palchan, T.; Zigler, A.; Sugiyama, K.; Nakajima, K.; Kaganovich, D.; Hubbard, R. F.; Ting, A.; Gordon, D. F.; Sprangle, P.; Fraenkel, M.; Maman, S.; Henis, Z.

    Plasma channels have been widely used to guide intense laser pulses over many Rayleigh lengths. Using optimized segmented capillary discharges, we demonstrated guided propagation of ultra short (100 fs) high intensity (1016 W/cm-2, limited by the laser system) pulses over distances up to 12.6 cm and intensities above 1018W/cm2 for 1.5cm boron nitride capillary. Both radial and longitudinal density profiles of plasma channels were studied under various discharge conditions. A new diagnostic technique is presented in which the transport of a guided laser pulse at different delay times from the initiation of the discharge is sampled on a single discharge shot. Using external, 10 nsec Nd YAG laser of several tenths of milijoules to ignite polyethylene capillaries we have demonstrated channels of various length in density range of 1017 - 1019 cm-3 and up to 25% deep. The longitudinal profiles were found to be remarkably uniform in both short and long capillaries. The Boron Nitride capillary has provided a guiding medium that can withstand more than 1000 shots. Using these capillaries we have guided laser intensities above 1018W/cm2. The laser ignition of capillary discharge provided reliable almost jitter free approach. The concerns related to influence of relatively high current density flow through capillary on the injected electrons were studied extensively by us both theoretically and experimentally using a simple injection method. The method is based on the interaction of a high intensity laser pulse with a thin wire placed near capillary entrance. The influence of magnetic fields was found to be insignificant. Using this method we have studied transport of electrons though capillary discharge.

  13. Characterizing Long-term Contaminant Mass Discharge and the Relationship Between Reductions in Discharge and Reductions in Mass for DNAPL Source Areas

    PubMed Central

    Matthieu, D.E.; Carroll, K.C.; Mainhagu, J.; Morrison, C.; McMillan, A.; Russo, A.; Plaschke, M.

    2013-01-01

    The objective of this study was to characterize the temporal behavior of contaminant mass discharge, and the relationship between reductions in contaminant mass discharge and reductions in contaminant mass, for a very heterogeneous, highly contaminated source-zone field site. Trichloroethene is the primary contaminant of concern, and several lines of evidence indicate the presence of organic liquid in the subsurface. The site is undergoing groundwater extraction for source control, and contaminant mass discharge has been monitored since system startup. The results show a significant reduction in contaminant mass discharge with time, decreasing from approximately 1 to 0.15 kg/d. Two methods were used to estimate the mass of contaminant present in the source area at the initiation of the remediation project. One was based on a comparison of two sets of core data, collected 3.5 years apart, which suggests that a significant (~80%) reduction in aggregate sediment-phase TCE concentrations occurred between sampling events. The second method was based on fitting the temporal contaminant mass discharge data with a simple exponential source-depletion function. Relatively similar estimates, 784 and 993 kg, respectively, were obtained with the two methods. These data were used to characterize the relationship between reductions in contaminant mass discharge (CMDR) and reductions in contaminant mass (MR). The observed curvilinear relationship exhibits a reduction in contaminant mass discharge essentially immediately upon initiation of mass reduction. This behavior is consistent with a system wherein significant quantities of mass are present in hydraulically poorly accessible domains for which mass removal is influenced by rate-limited mass transfer. The results obtained from the present study are compared to those obtained from other field studies to evaluate the impact of system properties and conditions on mass-discharge and mass-removal behavior. The results indicated that factors such as domain scale, hydraulic-gradient status (induced or natural), and flushing-solution composition had insignificant impact on the CMDR-MR profiles and thus on underlying mass-removal behavior. Conversely, source-zone age, through its impact on contaminant distribution and accessibility, was implicated as a critical factor influencing the nature of the CMDR-MR relationship. PMID:23528743

  14. Properties of mechanically alloyed Mg-Ni-Ti ternary hydrogen storage alloys for Ni-MH batteries

    NASA Astrophysics Data System (ADS)

    Ruggeri, Stéphane; Roué, Lionel; Huot, Jacques; Schulz, Robert; Aymard, Luc; Tarascon, Jean-Marie

    MgNiTi x, Mg 1- xTi xNi and MgNi 1- xTi x (with x varying from 0 to 0.5) alloys have been prepared by high energy ball milling and tested as hydrogen storage electrodes. The initial discharge capacities of the Mg-Ni-Ti ternary alloys are inferior to the MgNi electrode capacity. However, an exception is observed with MgNi 0.95Ti 0.05, which has an initial discharge capacity of 575 mAh/g compared to 522 mAh/g for the MgNi electrode. The Mg-Ni-Ti ternary alloys show improved cycle life compared to Mg-Ni binary alloys with the same Mg/Ni atomic ratio. The best cycle life is observed with Mg 0.5Ti 0.5Ni electrode which retains 75% of initial capacity after 10 cycles in comparison to 39% for MgNi electrodes, in addition to improved high-rate dischargeability (HRD). According to the XPS analysis, the cycle life improvement of the Mg 0.5Ti 0.5Ni electrode can be related to the formation of TiO 2 which limits Mg(OH) 2 formation. The anodic polarization curve of Mg 0.5Ti 0.5Ni electrode shows that the current related to the active/passive transition is much less important and that the passive region is more extended than for the MgNi electrode but the corrosion of the electrode is still significant. This suggests that the cycle life improvement would be also associated with a decrease of the particle pulverization upon cycling.

  15. Hollow cathode restartable 15 cm diameter ion thruster

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1973-01-01

    The effects of substituting high perveance dished grids for low perveance flat ones on performance variables and plasma properties within a 15 cm modified SERT II thruster are discussed. Results suggest good performance may be achieved as an ion thruster is throttled if the screen grid transparency is decreased with propellant flow rate. Thruster startup tests, which employ a pulsed high voltage tickler electrode between the keeper and the cathode to initiate the discharge, are described. High startup reliability at cathode tip temperatures of about 500 C without excessive component wear over 2000 startup cycles is demonstrated. Testing of a single cusp magnetic field concept of discharge plasma containment is discussed. A theory which explains the observed behavior of the device is presented and proposed thruster modifications and future testing plans are discussed.

  16. Pulsed discharges produced by high-power surface waves

    NASA Astrophysics Data System (ADS)

    Böhle, A.; Ivanov, O.; Kolisko, A.; Kortshagen, U.; Schlüter, H.; Vikharev, A.

    1996-02-01

    The mechanisms of the ionization front advance in surface-wave-produced discharges are investigated using two experimental set-ups. The high-power surface waves are excited in a 3 cm wavelength band by a surfaguide and a novel type of launcher (an E-plane junction). The ionization front velocity of the surface wave is measured for a wide range of gas pressures, incident microwave power and initial pre-ionization. The experimental results are compared with theoretical ones based on three different models. The comparison between theory and experiment allows one to suggest a new interpretation of the ionization front's advance. The ionization front velocity is determined by a breakdown wave or an ionization wave in the electric field of a high-power surface wave in the zone near the ionization front.

  17. Investigation of the delay time distribution of high power microwave surface flashover

    NASA Astrophysics Data System (ADS)

    Foster, J.; Krompholz, H.; Neuber, A.

    2011-01-01

    Characterizing and modeling the statistics associated with the initiation of gas breakdown has proven to be difficult due to a variety of rather unexplored phenomena involved. Experimental conditions for high power microwave window breakdown for pressures on the order of 100 to several 100 torr are complex: there are little to no naturally occurring free electrons in the breakdown region. The initial electron generation rate, from an external source, for example, is time dependent and so is the charge carrier amplification in the increasing radio frequency (RF) field amplitude with a rise time of 50 ns, which can be on the same order as the breakdown delay time. The probability of reaching a critical electron density within a given time period is composed of the statistical waiting time for the appearance of initiating electrons in the high-field region and the build-up of an avalanche with an inherent statistical distribution of the electron number. High power microwave breakdown and its delay time is of critical importance, since it limits the transmission through necessary windows, especially for high power, high altitude, low pressure applications. The delay time distribution of pulsed high power microwave surface flashover has been examined for nitrogen and argon as test gases for pressures ranging from 60 to 400 torr, with and without external UV illumination. A model has been developed for predicting the discharge delay time for these conditions. The results provide indications that field induced electron generation, other than standard field emission, plays a dominant role, which might be valid for other gas discharge types as well.

  18. Oxidative Degradation of 4-chlorophenol in Aqueous Induced by Plasma with Submersed Glow Discharge Electrolysis

    NASA Astrophysics Data System (ADS)

    Pu, Lumei; Gao, Jinzhang; Yang, Wu; Li, Yan; Yu, Jie; Huang, Dongling

    2005-10-01

    The oxidative degradation of 4-chlorophenol (4-CP) in aqueous solution induced by plasma with submersed glow discharge has been investigated. The concentration of 4-CP and the reaction intermediates were determined by high performance liquid chromatography (HPLC). Various influencing factors such as the initial pH, the concentration of 4-CP and the catalytic action of Fe2+ were examined. The results indicate that 4-CP is eventually degraded into inorganic ion, dioxide carbon and water. The attack of hydroxyl radicals on the benzene rings of 4-CP in the initial stage of oxidative reactions is presumed to be a key step. They also suggest that the reaction is of a pseudo-first order kinetic reaction and the proposed method is an efficient way for the 4-CP degradation.

  19. Scalable synthesis of Na3V2(PO4)(3)/C porous hollow spheres as a cathode for Na-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, JF; Luo, C; Gao, T

    2015-01-01

    Na3V2(PO4)(3) (NVP) has been considered as a very promising cathode material for sodium-ion batteries (SIBs) due to its typical NASICON structure, which provides an open and three dimensional (3D) framework for Na+ migration. However, the low electronic conductivity of NVP limits its rate capability and cycling ability. In this study, carbon coated hollow structured NVP/C composites are synthesized via a template-free and scalable ultrasonic spray pyrolysis process, where the carbon coated NVP particles are uniformly decorated on the inner and outer surfaces of the porous hollow carbon spheres. When evaluated as a cathode material for SIBs, the unique NVP/C porousmore » hollow sphere cathode delivers an initial discharge capacity of 99.2 mA h g(-1) and retains 89.3 mA h g(-1) after 300 charge/discharge cycles with a very low degradation rate of 0.035% per cycle. For comparison, the NVP/C composite, prepared by the traditional sol-gel method, delivers a lower initial discharge capacity of 97.4 mA h g(-1) and decreases significantly to 71.5 mA h g(-1) after 300 cycles. The superior electrochemical performance of NVP/C porous hollow spheres is attributed to their unique porous, hollow and spherical structures, as well as the carbon-coating layer, which provides a high contact area between electrode/electrolyte, high electronic conductivity, and high mechanical strength.« less

  20. An Analysis of Two Thunderstorms Producing Five Negative Sprites on 12 September 2014

    NASA Astrophysics Data System (ADS)

    Boggs, L.; Liu, N.; Splitt, M. E.; Lazarus, S. M.; Cummer, S. A.; Rassoul, H.

    2015-12-01

    We present a detailed analysis of the thunderstorms and the parent lightning discharge morphologies of five confirmed negative sprites taking place in two different thunderstorms. These two thunderstorms took place in east-central and south Florida on 12 September 2014. We utilized several lightning location networks, remote magnetic field measurements, dual polarization radar, and balloon borne soundings in our analysis. Each parent discharge was immediately preceded by intra-cloud (IC) discharges between the mid-level negative and upper positive charge regions. This either allowed a second upward negative leader to escape the upper positive charge region, or encouraged a downward negative leader to be initiated and connect with ground. The discharges found in this study support the findings of Lu et al., 2012 [JGR,117, D04212, 2012] that negative sprite-parent lightning consists primarily of hybrid intra-cloud negative cloud-to-ground (IC-NCG) and bolt-from-the-blue (BFB) lightning. Our work finds these unique discharges form in thunderstorms that have an excess of mid-level negative charge and weakened upper positive charge. Due to this charge structure, these unusual discharges transfer more charge to the ground than typical negative cloud-to-ground discharges. Our study suggests that the key difference separating bolt-from-the-blue and gigantic jet discharges is an asymmetric charge structure. This acts to bring the negative leader exiting the thundercloud closer to the lateral positive screening layer, encouraging the negative leader to turn towards ground. This investigation reveals IC discharges that involve multiple convective cells and come to ground as a negative CG discharge, a breed of hybrid IC-NCG discharges, also transfer more negative charge to ground than typical negative CG discharges and are able to initiate negative sprites. From this work, the charge structures mentioned above resulted from tall, intense convective cells with low CG flash rates with high wind shear in the mid to upper regions of the cloud. This acted to create a large reservoir of mid-level negative charge and create a general asymmetry to the charge structure. The wind shear in the upper regions also acted to weaken the upper positive charge by turbulent mixing with the upper negative screening charge layer.

  1. Reduced Graphene Oxide-Wrapped FeS2 Composite as Anode for High-Performance Sodium-Ion Batteries

    NASA Astrophysics Data System (ADS)

    Wang, Qinghong; Guo, Can; Zhu, Yuxuan; He, Jiapeng; Wang, Hongqiang

    2018-06-01

    Iron disulfide is considered to be a potential anode material for sodium-ion batteries due to its high theoretical capacity. However, its applications are seriously limited by the weak conductivity and large volume change, which results in low reversible capacity and poor cycling stability. Herein, reduced graphene oxide-wrapped FeS2 (FeS2/rGO) composite was fabricated to achieve excellent electrochemical performance via a facile two-step method. The introduction of rGO effectively improved the conductivity, BET surface area, and structural stability of the FeS2 active material, thus endowing it with high specific capacity, good rate capability, as well as excellent cycling stability. Electrochemical measurements show that the FeS2/rGO composite had a high initial discharge capacity of 1263.2 mAh g-1 at 100 mA g-1 and a high discharge capacity of 344 mAh g-1 at 10 A g-1, demonstrating superior rate performance. After 100 cycles at 100 mA g-1, the discharge capacity remained at 609.5 mAh g-1, indicating the excellent cycling stability of the FeS2/rGO electrode.

  2. Preliminary Results From a Laboratory Study of Positive Streamer Discharges on Simulated Ice Hydrometeors

    NASA Astrophysics Data System (ADS)

    Petersen, D.; Bailey, M.; Hallett, J.; Beasley, W.

    2007-12-01

    The initiation of lightning remains an open question, due in large part to a deficit of in-situ observational evidence. Recent theoretical descriptions of lightning initiation have focused on runaway breakdown and related secondary processes, but have not convincingly explained the details of onset of the embryonic lightning leader channel. Among possible mechanisms contributing to the initial leader formation are positive streamer discharges from ice hydrometeors, themselves once favored as the primary explanation of lightning initiation. We present preliminary results from a new laboratory study of positive streamer discharges on simulated ice hydrometeors. Emphasis is given to precisely defining the minimum electric field strength required for onset of positive streamer generation, with variables of interest being ice crystal size, habit and environmental temperature.

  3. Preceding muscle activity influences motor unit discharge and rate of torque development during ballistic contractions in humans

    PubMed Central

    Van Cutsem, Michaël; Duchateau, Jacques

    2005-01-01

    To investigate the effect of initial conditions on the modulation of motor unit discharge during fast voluntary contractions, we compared ballistic isometric contractions of the ankle dorsiflexor muscles that were produced from either a resting state or superimposed on a sustained contraction. The torque of the dorsiflexors and the surface and intramuscular EMGs from the tibialis anterior were recorded. The results showed that the performance of a ballistic contraction from a sustained contraction (∼25% maximal voluntary contraction (MVC)) had a negative effect on the maximal rate of torque development. Although the electromechanical delay was shortened, the EMG activity during the ballistic contraction was less synchronized. These observations were associated with a significant decline in the average discharge rate of single motor units (89.8 ± 3.8 versus 115 ± 5.8 Hz) and in the percentage of units (6.2 versus 15.5% of the whole sample) that exhibited double discharges at brief intervals (= 5 ms). High-threshold units that were not recruited during the sustained contraction displayed the same activation pattern, which indicates that the mechanisms responsible for the decline in discharge rate were not restricted to previously activated units, but appear to influence the entire motor unit pool. When a premotor silent period (SP) was observed at the transition from the sustained muscular activity to the ballistic contraction (19% of the trials), these adjustments in motor unit activity were not present, and the ballistic contractions were similar to those performed from a resting state. Together, these results indicate that initial conditions can influence the capacity for motor unit discharge rate and hence the performance of a fast voluntary contraction. PMID:15539402

  4. Incidence and predictors of 30-day readmission for patients discharged home after craniotomy for malignant supratentorial tumors in California (1995-2010).

    PubMed

    Marcus, Logan P; McCutcheon, Brandon A; Noorbakhsh, Abraham; Parina, Ralitza P; Gonda, David D; Chen, Clark; Chang, David C; Carter, Bob S

    2014-05-01

    Hospital readmission within 30 days of discharge is a major contributor to the high cost of health care in the US and is also a major indicator of patient care quality. The purpose of this study was to investigate the incidence, causes, and predictors of 30-day readmission following craniotomy for malignant supratentorial tumor resection. The longitudinal California Office of Statewide Health Planning & Development inpatient-discharge administrative database is a data set that consists of 100% of all inpatient hospitalizations within the state of California and allows each patient to be followed throughout multiple inpatient hospital stays, across multiple institutions, and over multiple years (from 1995 to 2010). This database was used to identify patients who underwent a craniotomy for resection of primary malignant brain tumors. Causes for unplanned 30-day readmission were identified by principle ICD-9 diagnosis code and multivariate analysis was used to determine the independent effect of various patient factors on 30-day readmissions. A total of 18,506 patients received a craniotomy for the treatment of primary malignant brain tumors within the state of California between 1995 and 2010. Four hundred ten patients (2.2%) died during the index surgical admission, 13,586 patients (73.4%) were discharged home, and 4510 patients (24.4%) were transferred to another facility. Among patients discharged home, 1790 patients (13.2%) were readmitted at least once within 30 days of discharge, with 27% of readmissions occurring at a different hospital than the initial surgical institution. The most common reasons for readmission were new onset seizure and convulsive disorder (20.9%), surgical infection of the CNS (14.5%), and new onset of a motor deficit (12.8%). Medi-Cal beneficiaries were at increased odds for readmission relative to privately insured patients (OR 1.52, 95% CI 1.20-1.93). Patients with a history of prior myocardial infarction were at an increased risk of readmission (OR 1.64, 95% CI 1.06-2.54) as were patients who developed hydrocephalus (OR 1.58, 95% CI 1.20-2.07) or venous complications during index surgical admission (OR 3.88, 95% CI 1.84-8.18). Using administrative data, this study demonstrates a baseline glioma surgery 30-day readmission rate of 13.2% in California for patients who are initially discharged home. This paper highlights the medical histories, perioperative complications, and patient demographic groups that are at an increased risk for readmission within 30 days of home discharge. An analysis of conditions present on readmission that were not present at the index surgical admission, such as infection and seizures, suggests that some readmissions may be preventable. Discharge planning strategies aimed at reducing readmission rates in neurosurgical practice should focus on patient groups at high risk for readmission and comprehensive discharge planning protocols should be implemented to specifically target the mitigation of potentially preventable conditions that are highly associated with readmission.

  5. Summary and Evaluation of the Strategic Defense Initiative Space Power Architecture Study

    DTIC Science & Technology

    1989-03-01

    coolant as fuel) and operates at high efficiency . It was also lower in vibration and dynamic effects than the combustion turbine. The fuel cell ...achievable with development. The main question with fuel cells is — can both high power density and high efficiency be achieved simultaneously? In...energy in a flywheel, fuel cell (power an electrolyzer) or battery. High power for weapon burst is obtained by discharging the storage device over a

  6. Estimated predevelopment discharge to streams from the High Plains Aquifer in northwestern Oklahoma, southwestern Kansas, and northwestern Texas

    USGS Publications Warehouse

    Luckey, R.R.; Becker, M.F.

    1998-01-01

    A study of the High Plains aquifer in Okla homa was initiated in 1996 to: (1) provide the information needed by the Oklahoma Water Resources Board to manage the quantity of water produced from the aquifer; and (2) provide base line water-chemistry data. The approach used to meet the first objective is to develop a digital ground-water flow model. The model will be cali brated, in part, by comparing simulated and esti mated predevelopment discharge from the aquifer to streams and cross-boundary flow. This report presents the estimated predevelopment discharge to streams from the High Plains aquifer. Streamflow data were the primary source of information used to estimate predevelopment dis charge from the High Plains aquifer. Data from 30 streamflow stations between the Arkansas and Canadian Rivers were considered in the analysis, and winter low-flow frequencies for 7-, 14-, and 30-day periods were determined for 25 stations. The 14-day low flow with a recurrence interval of 2 years was the primary value used to estimate pre development discharge from the aquifer. The streams that drain the eastern part of the High Plains aquifer in Kansas (generally east of 99.5 longitude) are estimated to have had large predevelopment discharge from the aquifer, and most of them received discharge from near their headwaters. For streams with more than one streamflow gage, the upper perennial reaches appeared to have gained more discharge from the aquifer than the lower reaches. The total predevel opment discharge from the aquifer in this area to several streams is estimated to have been about 312 cubic feet per second, not including discharge that probably went directly to the Arkansas River. The Cimarron River and its tributaries are estimated to have gained about 78 cubic feet per second, but nearly one-half that amount was lost in the lower reaches of the river. The cause of the loss in the lower reaches is unknown. The Beaver River and its tributaries are estimated to have gained a net of about 10 cubic feet per second above Wolf Creek with the upper reaches gaining more than the lower reaches. Wolf Creek is estimated to have gained 30 cubic feet per second over its total length.

  7. Sounding experiments of high pressure gas discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biele, Joachim K.

    A high pressure discharge experiment (200 MPa, 5{center_dot}10{sup 21} molecules/cm{sup 3}, 3000 K) has been set up to study electrically induced shock waves. The apparatus consists of the combustion chamber (4.2 cm{sup 3}) to produce high pressure gas by burning solid propellant grains to fill the electrical pump chamber (2.5 cm{sup 3}) containing an insulated coaxial electrode. Electrical pump energy up to 7.8 kJ at 10 kV, which is roughly three times of the gas energy in the pump chamber, was delivered by a capacitor bank. From the current-voltage relationship the discharge develops at rapidly decreasing voltage. Pressure at themore » combustion chamber indicating significant underpressure as well as overpressure peaks is followed by an increase of static pressure level. These data are not yet completely understood. However, Lorentz forces are believed to generate pinching with subsequent pinch heating, resulting in fast pressure variations to be propagated as rarefaction and shock waves, respectively. Utilizing pure axisymmetric electrode initiation rather than often used exploding wire technology in the pump chamber, repeatable experiments were achieved.« less

  8. Implementing wait-time reductions under Ontario government benchmarks (Pay-for-Results): a Cluster Randomized Trial of the Effect of a Physician-Nurse Supplementary Triage Assistance team (MDRNSTAT) on emergency department patient wait times

    PubMed Central

    2013-01-01

    Background Internationally, emergency departments are struggling with crowding and its associated morbidity, mortality, and decreased patient and health-care worker satisfaction. The objective was to evaluate the addition of a MDRNSTAT (Physician (MD)-Nurse (RN) Supplementary Team At Triage) on emergency department patient flow and quality of care. Methods Pragmatic cluster randomized trial. From 131 weekday shifts (8:00–14:30) during a 26-week period, we randomized 65 days (3173 visits) to the intervention cluster with a MDRNSTAT presence, and 66 days (3163 visits) to the nurse-only triage control cluster. The primary outcome was emergency department length-of-stay (EDLOS) for patients managed and discharged only by the emergency department. Secondary outcomes included EDLOS for patients initially seen by the emergency department, and subsequently consulted and admitted, patients reaching government-mandated thresholds, time to initial physician assessment, left-without being seen rate, time to investigation, and measurement of harm. Results The intervention’s median EDLOS for discharged, non-consulted, high acuity patients was 4:05 [95th% CI: 3:58 to 4:15] versus 4:29 [95th% CI: 4:19–4:38] during comparator shifts. The intervention’s median EDLOS for discharged, non-consulted, low acuity patients was 1:55 [95th% CI: 1:48 to 2:05] versus 2:08 [95th% CI: 2:02–2:14]. The intervention’s median physician initial assessment time was 0:55 [95th% CI: 0:53 to 0:58] versus 1:21 [95th% CI: 1:18 to 1:25]. The intervention’s left-without-being-seen rate was 1.5% versus 2.2% for the control (p = 0.06). The MDRNSTAT subgroup analysis resulted in significant decreases in median EDLOS for discharged, non-consulted high (4:01 [95th% CI: 3:43–4:16]) and low acuity patients (1:10 95th% CI: 0:58–1:19]), as well as physician initial assessment time (0:25 [95th% CI: 0:23–0:26]). No patients returned to the emergency department after being discharged by the MDRNSTAT at triage. Conclusions The intervention reduced delays and left-without-being-seen rate without increased return visits or jeopardizing urgent care of severely ill patients. Trial registration number NCT00991471 ClinicalTrials.gov PMID:24207160

  9. Correlated Lightning Mapping Array (LMA) and Radar Observations of the Initial Stages of Florida Triggered Lightning Discharges

    NASA Technical Reports Server (NTRS)

    Hill, J. D.; Pilkey, J.; Uman, M, A.; Jordan, D. M.; Biggerstaff, M. I.; Rison, W.; Blakeslee, R.

    2012-01-01

    We characterize the geometrical and electrical characteristics of the initial stages of nine Florida triggered lightning discharges using a Lightning Mapping Array (LMA), a C-band SMART radar, and measured channel-base currents. We determine initial channel and subsequent branch lengths, average initial channel and branch propagation speeds, and channel-base current at the time of each branch initiation. The channel-base current is found to not change significantly when branching occurs, an unexpected result. The initial stage of Florida triggered lightning typically transitions from vertical to horizontal propagation at altitudes of 3-6 km, near the typical 0 C level of 4-5 km and several kilometers below the expected center of the negative cloud-charge region at 7-8 km. The data presented potentially provide information on thunderstorm electrical and hydrometeor structure and discharge propagation physics. LMA source locations were obtained from VHF sources of positive impulsive currents as small as 10 A, in contrast to expectations found in the literature.

  10. Influence of High Speed Repetition of Pulsed Streamer Discharge Produced by Polarity-Reversed Traveling Wave on NO Oxidation

    NASA Astrophysics Data System (ADS)

    Matsuda, Eiji; Kadowaki, Kazunori; Nishimoto, Sakae; Kitani, Isamu

    This paper describes experimental results of NO removal from a simulated exhausted gas using a barrier-type plasma reactor subjected to reciprocal traveling wave voltage pulses. A pulse-forming cable was charged and then grounded at one end without any resistance, so that a traveling wave reciprocated along the cable with a change in its polarity because the traveling wave was negatively reflected at the grounded-end. Transient discharge light between point-plane electrodes with a glass barrier was observed using a gated image-intensifier. Photographs of the transient discharge light indicated that many streamer channels extended widely in the gap at the initial stage in the voltage oscillation, while only an intense discharge channel was observed at the latter stage. NO removal tests were carried out using the reciprocal pulse generator and a coaxial plasma reactor with a cylindrical glass-barrier. Results indicated that the discharges at the first and the second polarity reversals contributed largely to the oxidation reaction from NO into NO2, whereas the contribution of the subsequent discharges in the latter stage to NO removal was small.

  11. An Investigation of Ionic Wind Propulsion

    NASA Technical Reports Server (NTRS)

    Wilson, Jack; Perkins, Hugh D.; Thompson, William K.

    2009-01-01

    A corona discharge device generates an ionic wind and thrust, when a high voltage corona discharge is struck between sharply pointed electrodes and larger radius ground electrodes. The objective of this study was to examine whether this thrust could be scaled to values of interest for aircraft propulsion. An initial experiment showed that the thrust observed did equal the thrust of the ionic wind. Different types of high voltage electrodes were tried, including wires, knife-edges, and arrays of pins. A pin array was found to be optimum. Parametric experiments, and theory, showed that the thrust per unit power could be raised from early values of 5 N/kW to values approaching 50 N/kW, but only by lowering the thrust produced, and raising the voltage applied. In addition to using DC voltage, pulsed excitation, with and without a DC bias, was examined. The results were inconclusive as to whether this was advantageous. It was concluded that the use of a corona discharge for aircraft propulsion did not seem very practical.

  12. The influence of clarification and threats on life situation: patients’ experiences 1 year after TSCI

    PubMed Central

    Bjørnshave Noe, Bodil; Bjerrum, Merete; Angel, Sanne

    2017-01-01

    Introduction: The study was conducted at the Spinal Cord Injury Centre of Western Denmark (VCR). The aim of the study was to explore patients’ experiences following traumatic spinal cord injury and to identify characteristics of positive versus negative life situation 1 year post discharge from hospital rehabilitation. This was a qualitative study conducted using inductive content analysis. Case Presentation: In this qualitative study seven patients were interviewed one year after discharge from initial rehabilitation at the VCR. The interviews were analysed using inductive content analysis. Discussion: We found that two categories condensed the patients’ experiences of their life situation 1 year post discharge: ‘clarification in relation to overall life situation’ and ‘threat to core competences’. The transversal analysis across the derived categories identified different combinations of clarification and threats to core competences explaining the patients’ experiences: high degree of clarification combined with low degree of threat to core competences was indicative of positive life situation. Also, positive life situation was seen when a high degree of clarification compensated for high degree of threats on core competencies. In contrast, an overall stressful and negative life situation was influenced by poor clarification combined with a high degree of threat to core competences. However, when core competences can be transformed into new skills, threats were manageable. This study revealed that clarification related to overall life situation in combination with threat to core competences may explain traumatic spinal cord injury patients’ overall life situation 1 year post discharge. An appropriate balance characterises a positive life situation. There might be a need to pay attention to patients who are challenged by low degree of clarification and high degree of threats on core competencies 1 year post discharge as this may influence the life situation negatively. PMID:28435741

  13. Electrochemical Performance of a V2O5 Cathode for a Sodium Ion Battery

    NASA Astrophysics Data System (ADS)

    Van Nghia, Nguyen; Long, Pham Duy; Tan, Ta Anh; Jafian, Samuel; Hung, I.-Ming

    2017-06-01

    In this paper, layered vanadium pentoxide (V2O5) is employed as a cathode material for a sodium ion battery. The V2O5 particle sizes range from 200 nm to 500 nm and the shapes of the aggregated V2O5 particles are non-homogeneous and irregular. The material exhibits a first discharge capacity of approximately 208.1 mAh g-1. The structure of V2O5 changes to a NaxV2O5 structure after Na+ insertion at the first discharge; the structure of NaxV2O5 remains stable␣during cycling. After 40 cycles, the discharge capacity retains 61.2% of the capacity of the second cycle. The capacity of V2O5 at a high charge/discharge current rate of 1.0 C is 49.1% of capacity at 0.1 C. Furthermore, the capacity returns to the initial value as the discharge rate returns to 0.1 C. The results of electrochemical performance tests indicate that V2O5 is a potential cathode material for sodium ion batteries.

  14. Plasma formation in water vapour layers in high conductivity liquids

    NASA Astrophysics Data System (ADS)

    Kelsey, C. P.; Schaper, L.; Stalder, K. R.; Graham, W. G.

    2011-10-01

    The vapour layer development stage of relatively low voltage plasmas in conducting solutions has already been well explored. The nature of the discharges formed within the vapour layer however is still largely unexplored. Here we examine the nature of such discharges through a combination of fast imaging and spatially, temporally resolved spectroscopy and electrical characterisation. The experimental setup used is a pin-to-plate discharge configuration with a -350V, 200 μs pulse applied at a repetition rate of 2Hz. A lens, followed by beam splitter allows beams to one Andor ICCD camera to capture images of the plasma emission with a second camera at the exit of a high resolution spectrometer. Through synchronization of the camera images at specified times after plasma ignition (as determined from current-voltage characteristics) they can be correlated with the spectra features. Initial measurements reveal two apparently different plasma formations. Stark broadening of the hydrogen Balmer beta line indicate electron densities of 3 to 5 ×1020 m-3 for plasmas produced early in the voltage pulse and an order of magnitude less for the later plasmas. The vapour layer development stage of relatively low voltage plasmas in conducting solutions has already been well explored. The nature of the discharges formed within the vapour layer however is still largely unexplored. Here we examine the nature of such discharges through a combination of fast imaging and spatially, temporally resolved spectroscopy and electrical characterisation. The experimental setup used is a pin-to-plate discharge configuration with a -350V, 200 μs pulse applied at a repetition rate of 2Hz. A lens, followed by beam splitter allows beams to one Andor ICCD camera to capture images of the plasma emission with a second camera at the exit of a high resolution spectrometer. Through synchronization of the camera images at specified times after plasma ignition (as determined from current-voltage characteristics) they can be correlated with the spectra features. Initial measurements reveal two apparently different plasma formations. Stark broadening of the hydrogen Balmer beta line indicate electron densities of 3 to 5 ×1020 m-3 for plasmas produced early in the voltage pulse and an order of magnitude less for the later plasmas. Colin Kelsey is supported by a DEL NI PhD studentship.

  15. The electrochemical performance of aqueous rechargeable battery of Zn/Na0.44MnO2 based on hybrid electrolyte

    NASA Astrophysics Data System (ADS)

    Wu, Xianwen; Li, Yehua; Xiang, Yanhong; Liu, Zhixiong; He, Zeqiang; Wu, Xianming; Li, Youji; Xiong, Lizhi; Li, Chuanchang; Chen, Jian

    2016-12-01

    There is a broad application prospect for smart grid about aqueous rechargeable sodium-ion battery. In order to improve its electrochemical performance, a hybrid cationic aqueous-based rechargeable battery system based on the nanostructural Na0.44MnO2 and metallic zinc foil as the positive and negative electrodes respectively is built up. Nano rod-like Na0.44MnO2 is synthesized by sol-gel method followed by calcination at 850 °C for 9 h, and various characterization techniques including the X-ray diffraction (XRD) and scanning electron microscopy (SEM) are used to investigate the structure and morphology of the as-prepared material. The cyclic voltammetry, galvanostatic charge-discharge and self-discharge measurements are performed at the same time. The results show that the battery delivers a very high initial discharge capacity of 186.2 mAh g-1 at 0.2 C-rate in the range of 0.5-2.0 V, and it exhibits a discharge capacity of 113.3 mAh g-1 at high current density of 4 C-rate, indicative of excellent rate capability.

  16. Discharge prescribing of enteral opioids after initiation as a weaning strategy from continuous opioid infusions in the Intensive Care Unit.

    PubMed

    Kram, Bridgette; Weigel, Kylie M; Kuhrt, Michelle; Gilstrap, Daniel L

    To evaluate the proportion of patients receiving a hospital discharge prescription for a scheduled enteral opioid following initiation as a weaning strategy from a continuous opioid infusion in the Intensive Care Unit (ICU). Retrospective, observational study. Five adult ICUs at a large, quaternary care academic medical center. Endotracheally intubated, opioid-naive adults receiving a continuous opioid infusion with a concomitant scheduled enteral opioid initiated. Exclusion criteria were receipt of fewer than two enteral opioid doses, documentation of a long-acting opioid as a home medication, the indication for the enteral opioid was not a weaning strategy, death during hospital admission or discharge to hospice. None. The proportion of ICU and hospital survivors who received a discharge prescription for a scheduled enteral opioid, total duration of continuous opioid infusion, duration of continuous opioid infusion after initiation of an enteral opioid therapy, total duration of enteral therapy, ICU and hospital length of stay. Of 62 included patients, 19 patients (30.6 percent) received a new prescription for a scheduled enteral opioid at hospital discharge. The median duration of enteral opioid therapy was longer for patients who received a discharge prescription compared to those who did not (20.09 vs 8.89 days, p = 0.02), though the remaining endpoints were not different. Utilizing scheduled enteral opioids as a weaning strategy from continuous opioid infusions may place patients at risk of ICU-acquired physical dependence on opioids.

  17. Thermal Characterization Study of Lithium-Ion Cells

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.; Miller, Thomas B.; Bennett, William R.

    2007-01-01

    The primary challenge in designing a full scale lithium-ion (Li-ion) battery system is safety under both normal operating as well as abusive conditions. The normal conditions involve expected charge/discharge cycles and it is known that heat evolves in batteries during those cycles. This is a major concern in the design for high power applications and careful thermal management is necessary to alleviate this concern. An emerging thermal measurement technology, such as the electrochemical calorimetric of batteries, will aid in the development of advanced, safe battery system. To support this technology, several "commercial-off-the-shelf" (COTS) Li-ion cells with different chemistries and designs are being evaluated for different cycling regimes at a given operating temperature. The Accelerated Rate Calorimeter (ARC)-Arbin cycler setup is used to measure the temperature, voltage, and current of the cells at different charge/discharge rates. Initial results demonstrated good cell cyclability. During the cycle testing, the cell exhibited an endothermic cooling in the initial part of the charge cycle. The discharge portion of the cycle is exothermic during the entire discharge period. The presence of an endothermic reaction indicates a significant entropy effect during the beginning of charge cycle. Further studies will be performed to understand the thermal characteristics of the Li-ion cells at the different operating conditions. The effects on the thermal response on cell aging and states-of-charge will also be identified.

  18. Computational and experimental investigation of plasma deflagration jets and detonation shocks in coaxial plasma accelerators

    NASA Astrophysics Data System (ADS)

    Subramaniam, Vivek; Underwood, Thomas C.; Raja, Laxminarayan L.; Cappelli, Mark A.

    2018-02-01

    We present a magnetohydrodynamic (MHD) numerical simulation to study the physical mechanisms underlying plasma acceleration in a coaxial plasma gun. Coaxial plasma accelerators are known to exhibit two distinct modes of operation depending on the delay between gas loading and capacitor discharging. Shorter delays lead to a high velocity plasma deflagration jet and longer delays produce detonation shocks. During a single operational cycle that typically consists of two discharge events, the plasma acceleration exhibits a behavior characterized by a mode transition from deflagration to detonation. The first of the discharge events, a deflagration that occurs when the discharge expands into an initially evacuated domain, requires a modification of the standard MHD algorithm to account for rarefied regions of the simulation domain. The conventional approach of using a low background density gas to mimic the vacuum background results in the formation of an artificial shock, inconsistent with the physics of free expansion. To this end, we present a plasma-vacuum interface tracking framework with the objective of predicting a physically consistent free expansion, devoid of the spurious shock obtained with the low background density approach. The interface tracking formulation is integrated within the MHD framework to simulate the plasma deflagration and the second discharge event, a plasma detonation, formed due to its initiation in a background prefilled with gas remnant from the deflagration. The mode transition behavior obtained in the simulations is qualitatively compared to that observed in the experiments using high framing rate Schlieren videography. The deflagration mode is further investigated to understand the jet formation process and the axial velocities obtained are compared against experimentally obtained deflagration plasma front velocities. The simulations are also used to provide insight into the conditions responsible for the generation and sustenance of the magnetic pinch. The pinch width and number density distribution are compared to experimentally obtained data to calibrate the inlet boundary conditions used to set up the plasma acceleration problem.

  19. Modeling of a new electron-streamer acceleration mechanism

    NASA Astrophysics Data System (ADS)

    Ihaddadene, K. M. A.; Dwyer, J. R.; Liu, N.; Celestin, S. J.

    2017-12-01

    Lightning stepped leaders and laboratory spark discharges in air are known to produce X-rays [e.g., Dwyer et al., Geophys. Res. lett., 32, L20809, 2005; Kochkin et al., J. Phys. D: Appl. Phys., 45, 425202, 2012]. However, the processes behind the production of these X-rays are still not very well understood. During discharges, encounters between streamers of different polarities are very common. For example, during the formation of a new leader step, the negative streamer zone around the tip of a negative leader and the positive streamers initiated from the posiive part of a bidirectional space leader strongly interact. In laboratory experiments, when streamers are approaching a sharp electrode, streamers with the opposite polarity are initiated from the electrode and collide with the former streamers. Recently, the encounter between negative and positive streamers has been proposed as a plausible mechanism for the production of X-rays by spark discharges [Cooray et la., JASTP, 71, 1890, 2009; Kochkin et al., J. Phys. D: Appl. Phys., 45, 425202, 2012], but modeling results have shown later that the increase of the electric field involved in this process, which is above the conventional breakdown threshold field, is accompanied by a strong increase of the electron density. The resulting increase in the conductivity, in turn, causes this electric field to collapse over a few tens of picoseconds, preventing the electrons reaching high energies and producing significant X-ray emissions [e.g., Ihaddadene and Celestin, Geophys. Res. Lett., 45, 5644, 2015]. In this work, we will present simulation results of a new electron acceleration mechanism for producing runaway electron energies above hundred keV. The mechanism couples multiple single streamers and streamer head-on collisions, similar to a laboratory discharge, and is suitable for explaining the high-energy X-rays produced by discharges in air and by lightning stepped leaders.

  20. A power-balance model for local helicity injection startup in a spherical tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barr, Jayson L.; Bongard, Michael W.; Burke, Marcus G.

    A 0D circuit model for predicting I p( t) in Local Helicity Injection (LHI) discharges is developed. Analytic formulas for estimating the surface flux of finite-A plasmas developed are modified and expanded to treat highly shaped, ultralow-A tokamak geometry using a database of representative equilibria. Model predictions are compared to sample LHI discharges in the A ~ 1 Pegasus spherical tokamak, and are found to agree within 15% of experimental I p( t). High performance LHI discharges are found to follow the Taylor relaxation current limit for approximately the first half of the current ramp, or I p ≲ 75more » kA. The second half of the current ramp follows a limit imposed by power-balance as plasmas expand from high- A to ultralow- A. Here, this shape evolution generates a significant drop in external plasma inductance, effectively using the plasma’s initially high inductance to drive the current ramp and provide > 70% of the current drive V-s. Projections using this model indicate the relative influences of higher helicity input rate and injector current on the attainable total plasma current.« less

  1. A power-balance model for local helicity injection startup in a spherical tokamak

    DOE PAGES

    Barr, Jayson L.; Bongard, Michael W.; Burke, Marcus G.; ...

    2018-05-15

    A 0D circuit model for predicting I p( t) in Local Helicity Injection (LHI) discharges is developed. Analytic formulas for estimating the surface flux of finite-A plasmas developed are modified and expanded to treat highly shaped, ultralow-A tokamak geometry using a database of representative equilibria. Model predictions are compared to sample LHI discharges in the A ~ 1 Pegasus spherical tokamak, and are found to agree within 15% of experimental I p( t). High performance LHI discharges are found to follow the Taylor relaxation current limit for approximately the first half of the current ramp, or I p ≲ 75more » kA. The second half of the current ramp follows a limit imposed by power-balance as plasmas expand from high- A to ultralow- A. Here, this shape evolution generates a significant drop in external plasma inductance, effectively using the plasma’s initially high inductance to drive the current ramp and provide > 70% of the current drive V-s. Projections using this model indicate the relative influences of higher helicity input rate and injector current on the attainable total plasma current.« less

  2. Liquid Nitrogen as Fast High Voltage Switching Medium

    NASA Astrophysics Data System (ADS)

    Dickens, J.; Neuber, A.; Haustein, M.; Krile, J.; Krompholz, H.

    2002-12-01

    Compact pulsed power systems require new switching technologies. For high voltages, liquid nitrogen seems to be a suitable switching medium, with high hold-off voltage, low dielectric constant, and no need for pressurized systems as in high pressure gas switches. The discharge behavior in liquid nitrogen, such as breakdown voltages, formative times, current rise as function of voltage, recovery, etc. are virtually unknown, however. The phenomenology of breakdown in liquid nitrogen is investigated with high speed (temporal resolution < 1 ns) electrical and optical diagnostics, in a coaxial system with 50-Ohm impedance. Discharge current and voltage are determined with transmission line type current sensors and capacitive voltage dividers. The discharge luminosity is measured with photomultiplier tubes. Preliminary results of self-breakdown investigations (gap 1 mm, breakdown voltage 44 kV, non-boiling supercooled nitrogen) show a fast (2 ns) transition from an unknown current level to several mA, a long-duration (100 ns) phase with constant current superimposed by ns-spikes, and a final fast transition to the impedance limited current during several nanoseconds. The optical measurements will be expanded toward spectroscopy and high speed photography with the aim of clarifying the overall breakdown mechanisms, including electronic initiation, bubble formation, bubble dynamics, and their role in breakdown, for different electrode geometries (different macroscopic field enhancements).

  3. Assessing the Impact of Source-Zone Remediation Efforts at the Contaminant-Plume Scale Through Analysis of Contaminant Mass Discharge

    PubMed Central

    Brusseau, M. L.; Hatton, J.; DiGuiseppi, W.

    2011-01-01

    The long-term impact of source-zone remediation efforts was assessed for a large site contaminated by trichloroethene. The impact of the remediation efforts (soil vapor extraction and in-situ chemical oxidation) was assessed through analysis of plume-scale contaminant mass discharge, which was measured using a high-resolution data set obtained from 23 years of operation of a large pump-and-treat system. The initial contaminant mass discharge peaked at approximately 7 kg/d, and then declined to approximately 2 kg/d. This latter value was sustained for several years prior to the initiation of source-zone remediation efforts. The contaminant mass discharge in 2010, measured several years after completion of the two source-zone remediation actions, was approximately 0.2 kg/d, which is ten times lower than the value prior to source-zone remediation. The time-continuous contaminant mass discharge data can be used to evaluate the impact of the source-zone remediation efforts on reducing the time required to operate the pump-and-treat system, and to estimate the cost savings associated with the decreased operational period. While significant reductions have been achieved, it is evident that the remediation efforts have not completely eliminated contaminant mass discharge and associated risk. Remaining contaminant mass contributing to the current mass discharge is hypothesized to comprise poorly-accessible mass in the source zones, as well as aqueous (and sorbed) mass present in the extensive lower-permeability units located within and adjacent to the contaminant plume. The fate of these sources is an issue of critical import to the remediation of chlorinated-solvent contaminated sites, and development of methods to address these sources will be required to achieve successful long-term management of such sites and to ultimately transition them to closure. PMID:22115080

  4. Development and testing of a high cycle life 30 A-h sealed AgO-Zn battery

    NASA Technical Reports Server (NTRS)

    Bogner, R. S.

    1972-01-01

    A two-phase program was initiated to investigate design parameters and technology to develop an improved AgO-Zn battery. The basic performance goal was 100 charge/discharge cycles (22 h/2 h) at 50 percent depth of discharge following a six-month period of charged stand at room temperature. Phase 1, cell evaluation, involved testing 70 cells in five-cell groups. The major design variables were active material ratios, electrolyte concentrations, separator systems, and negative plate shape. Phase 1 testing showed that cycle life could be improved 10 percent to 20 percent by using greater ratios of zinc to silver oxide and higher electrolyte concentrations. Wedge-shaped negatives increased cycle life by nearly 100 percent. Phase 2 battery evaluation, which was initiated before the Phase 1 results were known completely, involved evaluation of six designs as 19-cell batteries. Only one battery exceeded 100 cycles following nine months charged stand.

  5. Self-learning control system for plug-in hybrid vehicles

    DOEpatents

    DeVault, Robert C [Knoxville, TN

    2010-12-14

    A system is provided to instruct a plug-in hybrid electric vehicle how optimally to use electric propulsion from a rechargeable energy storage device to reach an electric recharging station, while maintaining as high a state of charge (SOC) as desired along the route prior to arriving at the recharging station at a minimum SOC. The system can include the step of calculating a straight-line distance and/or actual distance between an orientation point and the determined instant present location to determine when to initiate optimally a charge depleting phase. The system can limit extended driving on a deeply discharged rechargeable energy storage device and reduce the number of deep discharge cycles for the rechargeable energy storage device, thereby improving the effective lifetime of the rechargeable energy storage device. This "Just-in-Time strategy can be initiated automatically without operator input to accommodate the unsophisticated operator and without needing a navigation system/GPS input.

  6. Development of a Micro-Fiber Nickel Electrode for Nickel-Hydrogen Cell

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1996-01-01

    The development of a high specific energy battery is one of the objectives of the lightweight nickel-hydrogen (NiH2) program at the NASA Lewis Research Center. The approach has been to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen fuel cell. Small fiber diameter nickel plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products and have an advantage of increased surface area available for the deposition of active materials. Initial tests include activation and capacity measurements at different discharge levels followed by half-cell cycle testing at 80 percent depth-of-discharge in a low Earth orbit regime. The electrodes that pass the initial tests are life cycle tested in a boiler plate nickel-hydrogen cell before flightweight designs are built and tested.

  7. Development of a micro-fiber nickel electrode for nickel-hydrogen cell

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1995-01-01

    Development of a high specific energy nickel electrode is the main goal of the lightweight nickel electrode program at the NASA Lewis Research Center. The approach has been to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen cell. Small fiber diameter nickel plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products and have an advantage of increased surface area available for the deposition of active material. Initial tests include activation and capacity measurements at different discharge levels followed by half-cell cycle testing at 80 percent depth-of-discharge in a low-Earth-orbit regime. The electrodes that pass the initial tests are life cycle-tested in a boiler plate nickel-hydrogen cell before flightweight designs are built and tested.

  8. Quantifying the fate of agricultural nitrogen in an unconfined aquifer: Stream-based observations at three measurement scales

    NASA Astrophysics Data System (ADS)

    Gilmore, Troy E.; Genereux, David P.; Solomon, D. Kip; Solder, John E.; Kimball, Briant A.; Mitasova, Helena; Birgand, François

    2016-03-01

    We compared three stream-based sampling methods to study the fate of nitrate in groundwater in a coastal plain watershed: point measurements beneath the streambed, seepage blankets (novel seepage-meter design), and reach mass-balance. The methods gave similar mean groundwater seepage rates into the stream (0.3-0.6 m/d) during two 3-4 day field campaigns despite an order of magnitude difference in stream discharge between the campaigns. At low flow, estimates of flow-weighted mean nitrate concentrations in groundwater discharge ([NO3-]FWM) and nitrate flux from groundwater to the stream decreased with increasing degree of channel influence and measurement scale, i.e., [NO3-]FWM was 654, 561, and 451 µM for point, blanket, and reach mass-balance sampling, respectively. At high flow the trend was reversed, likely because reach mass-balance captured inputs from shallow transient high-nitrate flow paths while point and blanket measurements did not. Point sampling may be better suited to estimating aquifer discharge of nitrate, while reach mass-balance reflects full nitrate inputs into the channel (which at high flow may be more than aquifer discharge due to transient flow paths, and at low flow may be less than aquifer discharge due to channel-based nitrate removal). Modeling dissolved N2 from streambed samples suggested (1) about half of groundwater nitrate was denitrified prior to discharge from the aquifer, and (2) both extent of denitrification and initial nitrate concentration in groundwater (700-1300 µM) were related to land use, suggesting these forms of streambed sampling for groundwater can reveal watershed spatial relations relevant to nitrate contamination and fate in the aquifer.

  9. Evaluation of the duration of thromboembolic prophylaxis after high-risk orthopaedic surgery: the ETHOS observational study.

    PubMed

    Bergqvist, David; Arcelus, Juan I; Felicissimo, Paulo

    2012-02-01

    Real-life data on post-discharge venous thromboembolism (VTE) prophylaxis practices and treatments are lacking. We assessed post-operative VTE prophylaxis prescribed and received in a prospective registry, compared with the 2004 American College of Chest Physicians (ACCP) guidelines in high-risk orthopaedic surgery patients. Consecutive patients undergoing total hip arthroplasty (THA), hip fracture surgery (HFS), or knee arthroplasty (KA) were enrolled at discharge from 161 centres in 17 European countries if they had received in-hospital VTE prophylaxis that was considered in accordance with the ACCP guidelines by the treating physician. Data on prescribed and actual prophylaxis were obtained from hospital charts and patient post-discharge diaries. Post-operative prophylaxis prescribed and actual prophylaxis received were considered adherent or adequate, respectively, if recommended therapies were used for ≥28 days (HFS and THA) or ≥10 days (KA). Among 4,388 patients, 69.9% were prescribed ACCP-adherent VTE prophylaxis (THA: 1,411/2,217 [63.6%]; HFS: 701/1,112 [63.0%]; KA: 955/1,059 [90.2%]). Actual prophylaxis received was described in 3,939 patients with an available diary after discharge (non-evaluability rate of 10%). Mean actual durations of pharmacological prophylaxis from surgery were: 28.4 ± 13.7 (THA), 29.3 ± 13.9 (HFS), and 28.7 ± 14.1 days (KA). ACCP-adequate VTE prophylaxis was received by 66.5% of patients (60.9% THA, 55.4% HFS, and 88.7% KA). Prophylaxis inadequacies were mainly due to inadequate prescription, non-recommended prophylaxis prescription at discharge, or too short prophylaxis prescribed. In high-risk orthopaedic surgery patients with hospital-initiated prophylaxis, there is a gap between ACCP recommendations, prescribed and actual prophylaxis received, mainly due to inadequate prescription at discharge.

  10. Reliability of self-reported smoking history and age at initial tobacco use.

    PubMed

    Huerta, Michael; Chodick, Gabriel; Balicer, Ran D; Davidovitch, Nadav; Grotto, Itamar

    2005-08-01

    Many studies use questionnaires to determine smoking status and age of smoking onset. This study aimed to determine the reliability of self-reported smoking history and age of smoking initiation. The proportion of inconsistent answers and correlation coefficients of reported age of initial smoking were measured by an answer-reanswer analysis of questionnaires in an ongoing, two-step, population-based survey of health behavior. Interviews were conducted on the day of recruitment to and the day of discharge from mandatory military service in Israel among a sample of 25,437 young men and women recruited between 1986 and 2000. Of 7276 participants reporting current or past smoking upon recruitment, 559 (7.7%) reported never having smoked upon discharge, thus demonstrating prima facie inconsistency. Variables significantly associated with reliable reporting in a multivariate logistic regression model were female gender (P = 0.04) and more than 4 years of military service (P < 0.01). 6010 subjects who reported a positive smoking history at both recruitment and discharge were available for analysis of reliability of reported age at smoking onset. Intraclass correlation coefficients for recruitment/discharge consistency in reported age at first cigarette were 0.73 (95% CI: 0.71-0.74) and 0.76 (95% CI: 0.74-0.78) for men and women, respectively. Eastern origin, lower subject education level, and lower paternal education level were also associated with lower reliability. Our results showed a relatively high level of answer-reanswer reliability, with some variance attributable to personal characteristics. These results suggest that self-reported age at onset of tobacco use is practical and reliable in normative, young adult populations. However, time elapsed between questionnaires and demographic and lifestyle characteristics may affect reliability rates, and thus should be carefully regarded in future studies.

  11. Fabrication of Na0.7MnO2/C composite cathode material by simple heat treatment for high-power na-ion batteries

    NASA Astrophysics Data System (ADS)

    Sohn, DongRak; Lim, Sung-Jin; Nam, Do-Hwan; Hong, Kyung-Sik; Kim, Tae-Hee; Oh, SeKwon; Eom, Ji-Yong; Cho, EunAe; Kwon, HyukSang

    2018-01-01

    A Na0.7MnO2/C composite cathode material is synthesized by simple and costeffective two-step heat treatment for an improvement in the rate capability of Na0.7MnO2. The first heat treatment is to synthesize Na0.7MnO2, and the second one is a low temperature annealing at 350 °C for 1 h in air, which is necessary to suppress an interfacial reaction between the Na0.7MnO2 and C in the synthesis process of Na0.7MnO2/C composite. Structural analyses by XRD and XPS reveal that the Na0.7MnO2/C shows the same structural properties as that of the pristine Na0.7MnO2, and hence they exhibit the same initial discharge capacity of 175 mAh g-1 at 20 mA g-1. At a current density of 400 mA g-1, the discharge capacity of Na0.7MnO2 reduces to 50 mAh g-1 (28% of the initial discharge capacity), whereas that of Na0.7MnO2/C reduces to 108 mAh g-1 (61% of the initial discharge capacity). The enhanced rate capability of the Na0.7MnO2/C is attributed to the conductive carbon layer formed on the surface of Na0.7MnO2 particles, enabling the facile transport of electrons from the current collector to the surface of the Na0.7MnO2 particles. [Figure not available: see fulltext.

  12. Operando Synchrotron XRD Investigation of Silver Metal Formation upon Electrochemical Reduction of Silver Iron Pyrophosphate (Ag 7Fe 3(P 2O 7) 4)

    DOE PAGES

    Zhang, Yiman; Kirshenbaum, Kevin C.; Marschilok, Amy C.; ...

    2017-05-11

    The formation of conductive metallic silver upon electrochemical reduction and lithiation of Ag 7Fe 3(P 2O 7) 4 is investigated. Alternating current impedance spectroscopy measurements show a 34% decrease in charge transfer resistance upon one electron equivalent (ee) of reduction, which is coincident with the formation of a Ag metal conductive network evidenced by both ex situ and operando X-ray diffraction. Quantitative assessment of Ag metal formation derived from operando XRD shows that only Ag + ions are reduced during the first 3ee, followed by simultaneous reduction of Ag + and Fe 3+ reduction for the next 5ee (3ee tomore » 8ee), culminating in reduction of the remaining Ag +. Scanning electron microscopy images show smaller Ag metal crystallite size and shorter nearest neighbor distance between and among Ag particles with higher depth of discharge. A high rate intermittent pulsatile discharge test is conducted where the cell delivers 12 total pulses during full discharge to probe the effect of Ag metal formation on the Li/Ag 7Fe 3(P 2O 7) 4 cell electrochemistry. The Ohmic resistance is derived from the voltage drop of each pulse. The resistance is 65 Ω initially, reaches its minimum of 26 Ω at 4.5 ee discharge, and levels off at 35 Ω after 7.0 ee reduction. In conclusion, the initial Ag reduction is more significant for the conductive network formation indicated by the decrease of both R ct and Ohmic resistance, which facilitates the high power output of the cell.« less

  13. Operando Synchrotron XRD Investigation of Silver Metal Formation upon Electrochemical Reduction of Silver Iron Pyrophosphate (Ag 7Fe 3(P 2O 7) 4)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yiman; Kirshenbaum, Kevin C.; Marschilok, Amy C.

    The formation of conductive metallic silver upon electrochemical reduction and lithiation of Ag 7Fe 3(P 2O 7) 4 is investigated. Alternating current impedance spectroscopy measurements show a 34% decrease in charge transfer resistance upon one electron equivalent (ee) of reduction, which is coincident with the formation of a Ag metal conductive network evidenced by both ex situ and operando X-ray diffraction. Quantitative assessment of Ag metal formation derived from operando XRD shows that only Ag + ions are reduced during the first 3ee, followed by simultaneous reduction of Ag + and Fe 3+ reduction for the next 5ee (3ee tomore » 8ee), culminating in reduction of the remaining Ag +. Scanning electron microscopy images show smaller Ag metal crystallite size and shorter nearest neighbor distance between and among Ag particles with higher depth of discharge. A high rate intermittent pulsatile discharge test is conducted where the cell delivers 12 total pulses during full discharge to probe the effect of Ag metal formation on the Li/Ag 7Fe 3(P 2O 7) 4 cell electrochemistry. The Ohmic resistance is derived from the voltage drop of each pulse. The resistance is 65 Ω initially, reaches its minimum of 26 Ω at 4.5 ee discharge, and levels off at 35 Ω after 7.0 ee reduction. In conclusion, the initial Ag reduction is more significant for the conductive network formation indicated by the decrease of both R ct and Ohmic resistance, which facilitates the high power output of the cell.« less

  14. Modeling terrestrial gamma ray flashes produced by relativistic feedback discharges

    NASA Astrophysics Data System (ADS)

    Liu, Ningyu; Dwyer, Joseph R.

    2013-05-01

    This paper reports a modeling study of terrestrial gamma ray flashes (TGFs) produced by relativistic feedback discharges. Terrestrial gamma ray flashes are intense energetic radiation originating from the Earth's atmosphere that has been observed by spacecraft. They are produced by bremsstrahlung interactions of energetic electrons, known as runaway electrons, with air atoms. An efficient physical mechanism for producing large fluxes of the runaway electrons to make the TGFs is the relativistic feedback discharge, where seed runaway electrons are generated by positrons and X-rays, products of the discharge itself. Once the relativistic feedback discharge becomes self-sustaining, an exponentially increasing number of relativistic electron avalanches propagate through the same high-field region inside the thundercloud until the electric field is partially discharged by the ionization created by the discharge. The modeling results indicate that the durations of the TGF pulses produced by the relativistic feedback discharge vary from tens of microseconds to several milliseconds, encompassing all durations of the TGFs observed so far. In addition, when a sufficiently large potential difference is available in thunderclouds, a self-propagating discharge known as the relativistic feedback streamer can be formed, which propagates like a conventional positive streamer. For the relativistic feedback streamer, the positive feedback mechanism of runaway electron production by the positrons and X-rays plays a similar role as the photoionization for the conventional positive streamer. The simulation results of the relativistic feedback streamer show that a sequence of TGF pulses with varying durations can be produced by the streamer. The relativistic streamer may initially propagate with a pulsed manner and turn into a continuous propagation mode at a later stage. Milliseconds long TGF pulses can be produced by the feedback streamer during its continuous propagation. However, the continuous propagation of the streamer tends to be unstable, because it does not expand like the conventional positive streamer. Its head electric field continues to increase and can reach half of the conventional breakdown threshold field, which results in an ion density of 3- 10×1014m-3 in the channel immediately following the head. The spatial width of the high field region in the streamer head is about 100 m and the streamer speed is about 5×105 m/s. As a result, conventional positive streamers can be initiated from thundercloud hydrometeors or inhomogeneities of enhanced conductivities of millimeter sizes in the relativistic feedback streamer head and the positive streamers may further result in the formation of leaders. In addition, a relativistic feedback streamer can result in a charge moment change of several tens of coulomb-kilometers in a few tens of milliseconds, indicating that the relativistic feedback discharge process could be an important component for thundercloud charge dynamics.

  15. Kinetics and Chemistry of Ionization Wave Discharges Propagating Over Dielectric Surfaces

    NASA Astrophysics Data System (ADS)

    Petrishchev, Vitaly

    Experimental studies of near-surface ionization wave electric discharges generated by high peak voltage (20-30 kV), nanosecond duration pulses (full width at half-maximum 50-100 ns) of positive and negative polarity and propagating over dielectric surfaces have been performed. A novel way to sustain diffuse, reproducible, ns pulse surface plasmas at a liquid-vapor interface is demonstrated at buffer gas pressures ranging from 10 to 200 Torr. Generation of surface ionization waves well reproduced shot-to-shot and sustaining diffuse near-surface plasmas is one of the principal advantages of the use of ns pulse discharge waveforms. This makes possible characterization of these plasmas in repetitively pulsed experiments. Numerous applications of these plasmas include low-temperature plasma assisted combustion, plasma fuel reforming, plasma flow control, plasma materials processing, agriculture, biology, and medicine. The objectives of the present work are (i) to demonstrate that surface ionization wave discharge plasmas sustained at a liquid-vapor interface can be used as an experimental platform for studies of near-surface plasma chemical reaction kinetics, at the conditions when the interface acts as a high-yield source of radical species, and (ii) to obtain quantitative insight into dynamics, kinetics and chemistry of surface ionization wave discharges and provide experimental data for validation of kinetic models, to assess their predictive capability. Generation of the initial radical pool may trigger a number of plasma chemical processes leading to formation of a variety of stable product species, depending on the initial composition of the liquid and the buffer gas flow. One of the products formed and detected during surface plasma / liquid water interaction is hydroxyl radical, which is closely relevant to applications of plasmas for biology and medicine. The present work includes detailed studies of surface ionization wave discharges sustained in different buffer gases over solid and liquid dielectric surfaces, such as quartz, distilled water, saline solution, and alcohols, over a wide range of pressures. Specific experiments include: measurements of ionization wave speed; plasma emission imaging using a ns gate camera; detection of surface discharge plasma chemistry products using Fourier transform infrared absorption spectroscopy; surface charge dynamics on short (ns) and long (hundreds of mus) time scales; time-resolved electron density and electron temperature measurements in a ns pulse surface discharge in helium by Thomson scattering; spatially-resolved absolute OH and H atom concentration measurements in ns pulse discharges over distilled water by single-photon and two-photon Laser Induced Fluorescence; and schlieren imaging of perturbations generated by a ns pulse dielectric barrier discharge in a surface plasma actuator in quiescent atmospheric pressure air.

  16. Sensitivity of energy-packed compounds based on superfine and nanoporous silicon to pulsed electrical treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zegrya, G. G.; Savenkov, G. G.; Morozov, V. A.

    2017-04-15

    The sensitivity of an energy-packed compound based on nanoporous silicon and calcium perchlorate to a high-current electron beam is studied. The initiation of explosive transformations in a mixture of potassium picrate with a highly dispersed powder of boron-doped silicon by means of a high-voltage discharge is examined. It is shown that explosive transformation modes (combustion and explosion) appear in the energy-packed compound under study upon its treatment with an electron beam. A relationship is established between the explosive transformation modes and the density of the energy-packed compound and between the breakdown (initiation) voltage and the mass fraction of the siliconmore » powder.« less

  17. Functional outcomes following the prosthetic training phase of rehabilitation after dysvascular lower extremity amputation

    PubMed Central

    Christiansen, Cory; Fields, Thomas; Lev, Guy; Stephenson, Ryan O.; Stevens-Lapsley, Jennifer E.

    2015-01-01

    Objective To describe physical function outcomes and modes of physical therapy intervention for a cohort of patients with dysvascular lower extremity amputation (LEA) during the prosthetic training phase of rehabilitation. Design A retrospective cohort study. Setting Physical rehabilitation clinics at a Veterans Affairs Medical Center and a University Hospital. Patients Forty-two patients (38 men, 4 women, age 60.2±8.4 years) who completed outpatient physical therapy rehabilitation with prosthetic training after dysvascular LEA. Methods All patients underwent a prosthetic training phase of rehabilitation, with standardized outcome measures performed at initiation and discharge. Main Outcome Measures Performance-based physical function measures included: Two-Minute Walk (2MW), Timed-Up and Go (TUG), and 5-meter gait speed. Self-report physical function measures included: the Prosthesis Evaluation Questionnaire – Mobility Section (PEQ-MS) and the Patient-Specific Functional Scale (PSFS). Rehabilitation dose was tracked as total number of clinic visits, rehabilitation duration, and specific intervention modes. Results There were significant improvements in 2MW (mean±SD) [67.5±29.9 m (initial) and 103.3±45.8 m (discharge) (p<0.001)], gait speed [0.58±0.27 m/s (initial) and 0.88±0.39 m/s (discharge) (p<0.001)], TUG [34.8±21.3 s (initial) and 18.6±13.9 s (discharge) (p<0.001)], PEQ-MS [2.2±0.9 (initial) and 2.8±0.8 (discharge) (p<0.001)], and PSFS [3.2±2.0 (initial) and 5.9±2.3 (discharge) (p<0.001)]. Performance-based (TUG) and self-report (PEQ-MS) changes in functional mobility from initial exam to discharge had low or no correlations with rehabilitation dose measures. Number of clinic visits was 12.7±13.1 and rehabilitation duration was 13.7±16.8 weeks. Conclusions Significant improvements in performance-based and self-report measures of physical function occurred during the prosthetic training phase of physical rehabilitation following dysvascular major LEA. Despite improvements in function, gait speed and TUG outcomes remained below clinically important thresholds, indicating patients were limited in community ambulation and at risk for falls. Lack of moderate or higher correlation between rehabilitation dose and outcome measures may indicate need for more specific rehabilitation dose measures. PMID:25978948

  18. Formation of Sn-M (M=Fe, Al, Ni) alloy nanoparticles by DC arc-discharge and their electrochemical properties as anodes for Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Gao, Song; Huang, Hao; Wu, Aimin; Yu, Jieyi; Gao, Jian; Dong, Xinglong; Liu, Chunjing; Cao, Guozhong

    2016-10-01

    A direct current arc-discharge method was applied to prepare the Sn-M (M=Fe, Al, Ni) bi-alloy nanoparticles. Thermodynamic is introduced to analyze the energy circumstances for the formation of the nanoparticles during the physical condensation process. The electrochemical properties of as-prepared Sn-M alloy nanoparticles are systematically investigated as anodes of Li-ion batteries. Among them, Sn-Fe nanoparticles electrode exhibits high Coulomb efficiency (about 71.2%) in the initial charge/discharge (257.9 mA h g-1/366.6 mA h g-1) and optimal cycle stability (a specific reversible capacity of 240 mA h g-1 maintained after 20 cycles) compared with others. Large differences in the electrochemical behaviors indicate that the chemical composition and microstructure of the nanoparticles determine the lithium-ion storage properties and the long-term cyclic stability during the charge/discharge process.

  19. Breakdown of methylene blue and methyl orange by pulsed corona discharge

    NASA Astrophysics Data System (ADS)

    Grabowski, L. R.; van Veldhuizen, E. M.; Pemen, A. J. M.; Rutgers, W. R.

    2007-05-01

    The recently developed corona above water technique is applied to water containing 10 mg l-1 methylene blue (MB) or methyl orange (MO). The corona discharge pulses are created with a spark gap switched capacitor followed by a transmission line transformer. The pulse amplitude is 40 kV; its duration is 50 ns. At a pulse repetition rate of 10 Hz this leads to an average power of 0.6 W into the discharge. MB and MO are completely decolourized in ~20 min. This corresponds to a yield of ~4.5 gr kW-1h-1, which is much higher than obtained with other discharge techniques or sonoluminescence. The high yield is reflected in the observed temperature increase of only ~1 K. Tests with additional chemicals show that the initial speed of the conversion can be influenced but the total time required for total decolourization is constant. Further, it follows that the main oxidation path of the dyes is by direct ozone attack and the conversion products are strong acids.

  20. Discharge Chamber Plasma Structure of a 30-cm NSTAR-Type Ion Engine

    NASA Technical Reports Server (NTRS)

    Herman, Daniel A.; Gallimore, Alec D.

    2006-01-01

    Single Langmuir probe measurements are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring cusp ion thruster over a range of thruster operating conditions encompassing the high-power half of the NASA throttling table. The Langmuir probe data were analyzed with two separate methods. All data were analyzed initially assuming an electron population consisting of Maxwellian electrons only. The on-axis data were then analyzed assuming both Maxwellian and primary electrons. Discharge plasma data taken with beam extraction exhibit a broadening of the higher electron temperature plume boundary compared to similar discharge conditions without beam extraction. The opposite effect is evident with the electron/ion number density as the data without began, extraction appears to be more collimated than the corresponding data with beam extraction. Primary electron energy and number densities are presented for one operating condition giving an order of magnitude of their value and the error associated with this calculation.

  1. Pulsed Power Discharges in Water

    NASA Astrophysics Data System (ADS)

    Kratel, Axel Wolf Hendrik

    An Electrohydraulic Discharge Process (EHD) for the treatment of hazardous chemical wastes in water has been developed. Liquid waste in a 4 L EHD reactor is directly exposed to high-energy pulsed electrical discharges between two submerged electrodes. The high-temperature (> 14,000 K) plasma channel created by an EHD discharge emits ultraviolet radiation, and produces an intense shock wave as it expands against the surrounding water. A simulation of the EHD process is presented along with experimental results. The simulation assumes a uniform plasma channel with a plasma that obeys the ideal gas law and the Spitzer conductivity law. The results agree with previously published data. The simulation is used to predict the total energy efficiency, energy partitioning, maximum plasma channel temperature and pressure for the Caltech Pulsed Power Facility (CPPF). The simulation shows that capacitance, initial voltage and gap length can be used to control the efficiency of the discharge. The oxidative degradation of 4-chlorophenol (4 -CP), 3,4-dichloroaniline (3,4-DCA), and 2,4,6 trinitrotoluene (TNT) in an EHD reactor was explored. The initial rates of degradation for the three substrates are described by a first-order rate equation, where k_{ it 0/} is the zero-order rate constant that accounts for direct photolysis; and k_ {it 1/} is the first-order term that accounts for oxidation in the plasma channel region. For 4-CP in the 4.0 L reactor, the values of these two rate constants are k_{it 0/} = 0.73 +/- 0.08 mu M, and k_{ it 1/} =(9.4 +/- 1.4) times 10^{-4}. For a 200 mu M 4-CP solution this corresponds to an overall intrinsic zero-order rate constant of 0.022 M s^{it -1/} , and a G-value of 4.45 times 10^{-3}. Ozone increases the rate and extent of degradation of the substrates in the EHD reactor. Combined EHD/ozone treatment of a 160 mu M TNT solution resulted in the complete degradation of TNT, and a 34% reduction of the total organic carbon (TOC). The intrinsic initial rate constant of TNT degradation was 0.024 M s^{it -1/} . The results of these experiments demonstrate the potential application of the EHD process for the treatment of hazardous wastes.

  2. Electrical burns of the abdomen.

    PubMed

    Srivastava, Rakesh Kumar; Kumar, Ritesh

    2013-09-01

    A 35-year-old male farmer came in contact with 11,000 volts high tension electric wire and sustained full thickness burn wounds over scapula, upper limb and anterior abdominal wall along with perforation of the intestine. Patient was initially managed conservatively in general surgery ward and was referred to us after 3 days with necrosis of the burned skin and muscles over the shoulder and abdomen. Patient was initially managed conservatively and then thorough debridement of the necrotic skin over the left shoulder and upper arm was done and the area was split skin grafted. Patient developed enterocutaneous fistula, which healed over a period of 8 weeks. The granulating wound over the abdomen was also skin grafted and patient was discharged after 18 days. About 4 months, after the discharge patient presented with ventral hernia. Repair of ventral hernia by synthetic mesh application and reconstruction of the abdominal wall with a free tensor fascia lata flap was done over the mesh, but the flap failed. Then after debridement two random pattern transposition skin flaps, one from the right upper and another from the left lower abdomen were transposed over the abdominal wound and donor area was skin grafted. Patient was discharged after 17 days.

  3. Polypyrrole-encapsulated vanadium pentoxide nanowires on a conductive substrate for electrode in aqueous rechargeable lithium battery.

    PubMed

    Liang, Chaowei; Fang, Dong; Cao, Yunhe; Li, Guangzhong; Luo, Zhiping; Zhou, Qunhua; Xiong, Chuanxi; Xu, Weilin

    2015-02-01

    Precursors of ammonium vanadium bronze (NH4V4O10) nanowires assembled on a conductive substrate were prepared by a hydrothermal method. After calcination at 360°C, the NH4V4O10 precursor transformed to vanadium pentoxide (V2O5) nanowires, which presented a high initial capacity of 135.0mA h g(-1) at a current density of 50mA g(-1) in 5M LiNO3 aqueous solution; while the specific capacity faded quickly over 50 cycles. By coating the surface of V2O5 nanowires with water-insoluble polypyrrole (PPy), the formed nanocomposite electrode exhibited a specific discharge capacity of 89.9mA h g(-1) at 50mA g(-1) (after 100 cycles). A V2O5@PPy //LiMn2O4 rechargeable lithium battery exhibited an initial discharge capacity of 95.2mA h g(-1); and after 100 cycles, a specific discharge capacity of 81.5mA h g(-1) could retain at 100mA g(-1). Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Safe discharge and outpatient investigation of ureteric colic: a retrospective analysis.

    PubMed

    Stewart, Michael

    2017-07-12

    Computed tomography of the kidneys, ureters and bladder is the recommended imaging modality for suspected urolithiasis. Early scanning is advised in guidelines, but there is limited published evidence to support this recommendation. In a retrospective study, we reviewed patients managed according to a local guideline. Patients without high-risk features were either imaged during their initial visit (if in the daytime) or discharged for outpatient scans. Complications, unplanned returns, final diagnosis, and intervention rates were compared between groups. Fifty-four patients were scanned during their initial visit and 151 were scanned as an outpatient at a median interval of 10 days. Unplanned return rates were lower in those scanned as outpatients (7.3 vs. 24.1%), with no significant difference in complications (2.0 vs. 3.7%; none leading to permanent harm). Those scanned as outpatients were less likely to have a stone proven by imaging (39.7 vs. 64.8%), but did not have a significantly higher rate of proven alternative diagnosis (9.3 vs. 13.0%). There is no evidence in this cohort that discharging patients for outpatient imaging is associated with poorer outcomes, provided that an appropriate clinical risk assessment is carried out.

  5. Efficient Radio Frequency Inductive Discharges in Near Atmospheric Pressure Using Immittance Conversion Topology

    NASA Astrophysics Data System (ADS)

    Razzak, M. Abdur; Takamura, Shuichi; Uesugi, Yoshihiko; Ohno, Noriyasu

    A radio frequency (rf) inductive discharge in atmospheric pressure range requires high voltage in the initial startup phase and high power during the steady state sustainment phase. It is, therefore, necessary to inject high rf power into the plasma ensuring the maximum use of the power source, especially where the rf power is limited. In order to inject the maximum possible rf power into the plasma with a moderate rf power source of few kilowatts range, we employ the immittance conversion topology by converting a constant voltage source into a constant current source to generate efficient rf discharge by inductively coupled plasma (ICP) technique at a gas pressure with up to one atmosphere in argon. A novel T-LCL immittance circuit is designed for constant-current high-power operation, which is practically very important in the high-frequency range, to provide high effective rf power to the plasma. The immittance conversion system combines the static induction transistor (SIT)-based radio frequency (rf) high-power inverter circuit and the immittance conversion elements including the rf induction coil. The basic properties of the immittance circuit are studied by numerical analysis and verified the results by experimental measurements with the inductive plasma as a load at a relatively high rf power of about 4 kW. The performances of the immittance circuit are also evaluated and compared with that of the conventional series resonance circuit in high-pressure induction plasma generation. The experimental results reveal that the immittance conversion circuit confirms injecting higher effective rf power into the plasma as much as three times than that of the series resonance circuit under the same operating conditions and same dc supply voltage to the inverter, thereby enhancing the plasma heating efficiency to generate efficient rf inductive discharges.

  6. Discharge destination's effect on bounce-back risk in Black, White, and Hispanic acute ischemic stroke patients.

    PubMed

    Kind, Amy J H; Smith, Maureen A; Liou, Jinn-Ing; Pandhi, Nancy; Frytak, Jennifer R; Finch, Michael D

    2010-02-01

    To determine whether racial and ethnic effects on bounce-back risk (ie, movement to settings of higher care intensity within 30 d of hospital discharge) in acute stroke patients vary depending on initial posthospital discharge destination. Retrospective analysis of administrative data. Four hundred twenty-two hospitals, southern/eastern United States. All Medicare beneficiaries 65 years or more with hospitalization for acute ischemic stroke within one of the 422 target hospitals during the years 1999 or 2000 (N=63,679). Not applicable. Adjusted predicted probabilities for discharge to and for bouncing back from each initial discharge site (ie, home, home with home health care, skilled nursing facility [SNF], or rehabilitation center) by race (ie, black, white, and Hispanic). Models included sociodemographics, comorbidities, stroke severity, and length of stay. Blacks and Hispanics were significantly more likely to be discharged to home health care (blacks=21% [95% confidence interval (CI), 19.9-22.8], Hispanic=19% [17.1-21.7] vs whites=16% [15.5-16.8]) and less likely to be discharged to SNFs (blacks=26% [95% CI, 23.6-29.3], Hispanics=28% [25.4-31.6] vs whites=33% [31.8-35.1]) than whites. However, blacks and Hispanics were significantly more likely to bounce back when discharged to SNFs than whites (blacks=26% [95% CI, 24.2-28.6], Hispanics=28% [24-32.6] vs whites=21% [20.3-21.9]). Hispanics had a lower risk of bouncing back when discharged home than either blacks or whites (Hispanics=14% [95% CI, 11.3-17] vs blacks=20% [18.4-22.2], whites=18% [16.8-18.3]). Patients discharged to home health care or rehabilitation centers demonstrated no significant differences in bounce-back risk. Racial/ethnic bounce-back risk differs depending on initial discharge destination. Additional research is needed to fully understand this variation in effect. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Removal of phenol by activated alumina bed in pulsed high-voltage electric field.

    PubMed

    Zhu, Li-nan; Ma, Jun; Yang, Shi-dong

    2007-01-01

    A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results indicated the increase in removal rate with increasing applied voltage, increasing pH value of the solution, aeration, and adding Fe2+. The removal rate of phenol could reach 72.1% when air aeration flow rate was 1200 ml/min, and 88.2% when 0.05 mmol/L Fe2+ was added into the solution under the conditions of applied voltage 25 kV, initial phenol concentration of 5 mg/L, and initial pH value 5.5. The addition of sodium carbonate reduced the phenol removal rate. In the pulsed high-voltage electric field, local discharge occurred at the surface of activated alumina, which promoted phenol degradation in the thin water film. At the same time, the space-time distribution of gas-liquid phases was more uniform and the contact areas of the activated species generated from the discharge and the pollutant molecules were much wider due to the effect of the activated alumina bed. The synthetical effects of the pulsed high-voltage electric field and the activated alumina particles accelerated phenol degradation.

  8. Hierarchical Li1.2Mn0.54Ni0.13Co0.13O2 hollow spherical as cathode material for Li-ion battery

    NASA Astrophysics Data System (ADS)

    Zhang, Yu; Zhu, Tianjiao; Lin, Liu; Yuan, Mengwei; Li, Huifeng; Sun, Genban; Ma, Shulan

    2017-11-01

    Lithium-rich manganese-based layered materials have been considered as the most promising cathode materials for future high-energy-density lithium-ion batteries. However, a great loss of irreversible capacity at the initial cycle, poor cycle stability, and rate performance severely restrict its application. Herein, we develop a new strategy to synthesize hierarchical hollow Li1.2Mn0.54Ni0.13Co0.13O2 microspheres using sucrose and cetyltrimethylammonium bromide as a soft template combined with hydrothermal assisted homogeneous precipitation method. The hollow microspheres are assembled by the primary particles with the size of 50 nm. As a result, the as-prepared material exhibits high reversible capacity, good cycling stability, and excellent rate property. It delivers a high initial discharge capacity of 305.9 mAh g-1 at 28 mA g-1 with coulombic efficiency of 80%. Even at high current density of 560 mA g-1, the sample also shows a stable discharge capacity of 215 mAh g-1. The enhanced electrochemical properties are attributed to the stable hierarchical hollow sphere structure and the appropriate contact area between electrode and electrolyte, thus effectively improve the lithium-ion intercalation and deintercalation kinetics. [Figure not available: see fulltext.

  9. Virtual Telemedicine Visits in Pediatric Home Parenteral Nutrition Patients: A Quality Improvement Initiative.

    PubMed

    Raphael, Bram P; Schumann, Caitlin; Garrity-Gentille, Sara; McClelland, Jennifer; Rosa, Carolyn; Tascione, Christina; Gallotto, Mary; Takvorian-Bené, Melissa; Carey, Alexandra N; McCarthy, Patrick; Duggan, Christopher; Ozonoff, Al

    2018-05-04

    Despite being less costly than prolonged hospitalization, home parenteral nutrition (HPN) is associated with high rates of post-discharge complications, including frequent readmissions and central line-associated bloodstream infections (CLABSIs). Telemedicine has been associated with improved outcomes and reduced healthcare utilization in other high-risk populations, but no studies to date have supported effectiveness of telemedicine in pediatric HPN. We prospectively collected data on pediatric patients managed at a single HPN program who participated in postdischarge telemedicine visits from March 1, 2014 to March 30, 2016. We excluded patients with a history of HPN and strictly palliative care goals. Univariate analysis was performed for primary outcomes: Community-acquired CLABSI and 30-day readmission rate. Twenty-six families participated in the pilot initiative with median (interquartile range) patient age 1.5 (5.7) years old, diagnosis of short bowel syndrome in 16 (62%), and in-state residence in 17 (55%). Ishikawa (fishbone) diagram identified causes of post-discharge HPN complications. Areas of focus during telemedicine visit included central venous catheter care methods, materials, clinical concerns, and equipment. Compared to historical comparison group, the telemedicine group experienced CLABSI rates of 1.0 versus 2.7 per 1,000 line days and readmission rates of 38% versus 17% (p = 0.03, 0.02, respectively). Telemedicine visits identified opportunities for improvement for families newly discharged on HPN. In a small cohort of patients who experienced telemedicine visits, we found lower CLABSI rates alongside higher readmission rates compared with a historical comparison group. Further studies are needed to optimize telemedicine in delivering care to this high-risk population.

  10. The effect of heat preservation time on the electrochemical properties of LiFePO4

    NASA Astrophysics Data System (ADS)

    He, Rui; Zhang, Lihui; Bai, Xue; Liu, Zhenfa

    2017-12-01

    LiFePO4 was prepared via high temperature solid-state method at different heat preservation time. XRD and SEM was used to test the structure and morphology of LiFePO4. Land 2001 was used to test the electrochemical performance of LiFePO4. The results illustrated that well-crystallized LiFePO4 composite with homogeneous small particles was obtained by XRD and SEM. And the optimum heat preservation time was 4 hour. From charge/discharge test, it can be seen that at 0.2C, LiFePO4 has initial discharge capacities of 159.1mAh/g at the heat preservation time 4 hour. From the rate capacity, it can be seen that the discharge capacity was of optimum sample remains above 99% after 200 cycles.

  11. Average discharge, perennial flow initiation, and channel initiation - small southern Appalachian basins

    Treesearch

    B. Lane Rivenbark; C. Rhett Jackson

    2004-01-01

    Regional average evapotranspiration estimates developed by water balance techniques are frequently used to estimate average discharge in ungaged strttams. However, the lower stream size range for the validity of these techniques has not been explored. Flow records were collected and evaluated for 16 small streams in the Southern Appalachians to test whether the...

  12. Data Sharing Between Providers and Quality Initiatives Eliminate Unnecessary Nursing Home Admissions.

    PubMed

    Charles, Ryan J; Singal, Bonita M; Urquhart, Andrew G; Masini, Michael A; Hallstrom, Brian R

    2017-05-01

    The Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) has monitored discharge disposition, after total hip and knee arthroplasties, since inception in 2012 and found the standardized risk of extended care facility (ECF) placement to be highly variable between hospitals. The variation in standardized risks of ECF placement among MARCQI member sites was reported to the collaborative. At the May 2, 2014 quarterly meeting, a quality initiative was started, emphasizing the wide variability between hospitals, the contribution of hospital and surgeon to that variability using median odds ratios, and the need for outlier hospitals to initiate quality improvement (QI) processes. Patients from 29 hospitals that were members of MARCQI before the intervention were included in this analysis. We compared standardized risks before and after the intervention in the entire cohort, and for 3 hospitals that implemented institution-specific QI projects. We report changes in ECF placement, length of stay, emergency room visits, and readmissions over time. This study includes 31,347 patients before and 20,879 patients after the implementation of the quality initiative. The range in standardized risk dropped from 9.4%-46.1% to 9.4%-32.4% and the average dropped from 23.0% to 19.6%. Three outlier hospitals decreased their absolute risk of ECF placement by 12.2%, 8.9%, and 12.4% after QI, without increases in adverse outcomes. Discharge to ECF after primary hip and knee arthroplasties is highly variable and influenced by hospital and surgeon practices. Hospital-level QI measures can decrease ECF admissions. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Development and feasibility testing of the Pediatric Emergency Discharge Interaction Coding Scheme.

    PubMed

    Curran, Janet A; Taylor, Alexandra; Chorney, Jill; Porter, Stephen; Murphy, Andrea; MacPhee, Shannon; Bishop, Andrea; Haworth, Rebecca

    2017-08-01

    Discharge communication is an important aspect of high-quality emergency care. This study addresses the gap in knowledge on how to describe discharge communication in a paediatric emergency department (ED). The objective of this feasibility study was to develop and test a coding scheme to characterize discharge communication between health-care providers (HCPs) and caregivers who visit the ED with their children. The Pediatric Emergency Discharge Interaction Coding Scheme (PEDICS) and coding manual were developed following a review of the literature and an iterative refinement process involving HCP observations, inter-rater assessments and team consensus. The coding scheme was pilot-tested through observations of HCPs across a range of shifts in one urban paediatric ED. Overall, 329 patient observations were carried out across 50 observational shifts. Inter-rater reliability was evaluated in 16% of the observations. The final version of the PEDICS contained 41 communication elements. Kappa scores were greater than .60 for the majority of communication elements. The most frequently observed communication elements were under the Introduction node and the least frequently observed were under the Social Concerns node. HCPs initiated the majority of the communication. Pediatric Emergency Discharge Interaction Coding Scheme addresses an important gap in the discharge communication literature. The tool is useful for mapping patterns of discharge communication between HCPs and caregivers. Results from our pilot test identified deficits in specific areas of discharge communication that could impact adherence to discharge instructions. The PEDICS would benefit from further testing with a different sample of HCPs. © 2017 The Authors. Health Expectations Published by John Wiley & Sons Ltd.

  14. Lower Hybrid Wave Induced SOL Emissivity Variation at High Density on the Alcator C-Mod Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faust, I.; Terry, J. L.; Reinke, M. L.

    Lower Hybrid Current Drive (LHCD) in the Alcator C-Mod tokamak provides current profile control for the generation of Advanced Tokamak (AT) plasmas. Non-thermal electron bremsstrahlung emission decreases dramatically at n-bar{sub e}>1{center_dot}10{sup 20}[m{sup -3}] for diverted discharges, indicating low current drive efficiency. It is suggested that Scrape-Off-Layer (SOL) collisional absorption of LH waves is the cause for the absence of non-thermal electrons at high density. VUV and visible spectroscopy in the SOL provide direct information on collision excitation processes. Deuterium Balmer-, Lyman- and He-I transition emission measurements were used for initial characterization of SOL electron-neutral collisional absorption. Data from Helium andmore » Deuterium LHCD discharges were characterized by an overall increase in the emissivity as well as an outward radial shift in the emissivity profile with increasing plasma density and applied LHCD power. High-temperature, high-field (T{sub e} = 5keV,B{sub t} = 8T) helium discharges at high density display increased non-thermal signatures as well as reduced SOL emissivity. Variations in emissivity due to LHCD were seen in SOL regions not magnetically connected to the LH Launcher, indicating global SOL effects due to LHCD.« less

  15. Electric oxygen-iodine laser discharge scaling and laser performance

    NASA Astrophysics Data System (ADS)

    Woodard, Brian S.

    In 2004, a research partnership between the University of Illinois and CU Aerospace demonstrated the first electric discharge pumped oxygen-iodine laser referred to as ElectricOIL. This exciting improvement over the standard oxygen-iodine laser utilizes a gas discharge to produce the necessary electronically-excited molecular oxygen, O2(a 1Delta), that serves as the energy reservoir in the laser system. Pumped by a near-resonant energy transfer, the atomic iodine lases on the I(2P1/2) → I(2P3/2) transition at 1315 nm. Molecular oxygen diluted with helium and a small fraction of nitric oxide flows through a radiofrequency discharge where O2(a 1Delta) and many other excited species are created. Careful investigations to understand the benefits and problems associated with these other states in the laser system allowed this team to succeed where other research groups had failed, and after the initial demonstration, the ElectricOIL research focus shifted to increasing the efficiencies along with the output laser energy. Among other factors, the laser power scales with the flow rate of oxygen in the desired excited state. Therefore, high yields of O2(a 1Delta) are desired along with high input oxygen flow rates. In the early ElectricOIL experiments, the pressure in the discharge was approximately 10 Torr, but increased flow rates forced the pressure to between 50 and 60 Torr requiring a number of new discharge designs in order to produce similar yields of O2(a1Delta) efficiently. Experiments were conducted with only the electric discharge portion of the laser system using emission diagnostics to study the effects of changing the discharge geometry, flow residence time, and diluent. The power carried by O2(a 1Delta) is the maximum power that could be extracted from the laser, and the results from these studies showed approximately 2500 W stored in the O2(a1Delta) state. Transferring this energy into the atomic iodine has been another challenge in ElectricOIL as experiments have shown that the iodine is pumped into the excited state slower than is predicted by the known kinetics, resulting in reduced output power. An elementary model is presented that may partially explain this problem. Larger laser resonator volumes are employed to improve power extraction by providing more flow time for iodine pumping. The results presented in this work in conjunction with the efforts of others led to ElectricOIL scaling from 200 mW in the initial demonstration to nearly 500 W.

  16. In situ fabrication of nickel based oxide on nitrogen-doped graphene for high electrochemical performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Pan, Denghui; Zhang, Mingmei; Wang, Ying; Yan, Zaoxue; Jing, Junjie; Xie, Jimin

    2017-10-01

    In this article, we synthesize Ni(OH)2 homogeneous grown on nitrogen-doped graphene (Ni(OH)2/NG), subsequently, small and uniform nickel oxide nanoparticle (NiO/NG) is also successfully obtained through tube furnace calcination method. The high specific capacitance of the NiO/NG electrode can reach to 1314.1 F/g at a charge and discharge current density of 2 A/g, meanwhile the specific capacitance of Ni(OH)2/NG electrode is also 1350 F/g. The capacitance of NiO/NG can remain 93.7% of the maximum value after 1000 cycles, while the Ni(OH)2/NG electrode losses 16.9% of the initial capacitance after 1000 cycles. It can be attributed to nickel hydroxide instability during charge-discharge cycles.

  17. Fluid modeling of a high-voltage nanosecond pulsed xenon microdischarge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levko, Dmitry; Raja, Laxminarayan L.

    2016-07-15

    A computational modeling study of high-voltage nanosecond pulsed microdischarge in xenon gas at 10 atm is presented. The discharge is observed to develop as two streamers originating from the cathode and the anode, and propagating toward each other until they merge to form a single continuous discharge channel. The peak plasma density obtained in the simulations is ∼10{sup 24 }m{sup −3}, i.e., the ionization degree of plasma does not exceed 1%. The influence of the initial gas pre-ionization is established. It is seen that an increase in the seeded plasma density results in an increase in the streamer propagation velocity andmore » an increase in the plasma density obtained after the merging of two streamers.« less

  18. Using Schlieren Visualization to Track Detonator Performance

    NASA Astrophysics Data System (ADS)

    Clarke, S. A.; Bolme, C. A.; Murphy, M. J.; Landon, C. D.; Mason, T. A.; Adrian, R. J.; Akinci, A. A.; Martinez, M. E.; Thomas, K. A.

    2007-12-01

    Several experiments will be presented that are part of a phased plan to understand the evolution of detonation in a detonator from initiation shock through run to detonation, to full detonation, to transition, to booster and booster detonation. High-speed multiframe schlieren imagery has been used to study several explosive initiation events, such as exploding bridgewires (EBWs), exploding foil initiators (EFIs or "slappers"), direct optical initiation (DOI), and electrostatic discharge. Additionally, a series of tests has been performed on "cut-back" detonators with varying initial pressing heights. We have also used this diagnostic to visualize a range of EBW, EFI, and DOI full-up detonators. Future applications to other explosive events, such as boosters and insensitive high explosives booster evaluation, will be discussed. The EPIC finite element code has been used to analyze the shock fronts from the schlieren images to solve iteratively for consistent boundary or initial conditions to determine the temporal-spatial pressure profile across the output face of the detonator.

  19. Acceleration Modes and Transitions in Pulsed Plasma Accelerators

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Greve, Christine M.

    2018-01-01

    Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma accelerators was developed by Cheng, et al. The Coaxial High ENerGy (CHENG) thruster operated on the 10-microseconds timescales of pulsed plasma thrusters, but claimed high thrust density, high efficiency and low electrode erosion rates, which are more consistent with the deflagration mode of acceleration. Separate work on gas-fed pulsed plasma thrusters (PPTs) by Ziemer, et al. identified two separate regimes of performance. The regime at higher mass bits (termed Mode I in that work) possessed relatively constant thrust efficiency (ratio of jet kinetic energy to input electrical energy) as a function of mass bit. In the second regime at very low mass bits (termed Mode II), the efficiency increased with decreasing mass bit. Work by Poehlmann et al. and by Sitaraman and Raja sought to understand the performance of the CHENG thruster and the Mode I / Mode II performance in PPTs by modeling the acceleration using the Hugoniot Relation, with the detonation and deflagration modes representing two distinct sets of solutions to the relevant conservation laws. These works studied the proposal that, depending upon the values of the various controllable parameters, the accelerator would operate in either the detonation or deflagration mode. In the present work, we propose a variation on the explanation for the differences in performance between the various pulsed plasma accelerators. Instead of treating the accelerator as if it were only operating in one mode or the other during a pulse, we model the initial stage of the discharge in all cases as an accelerating current sheet (detonation mode). If the current sheet reaches the exit of the accelerator before the discharge is completed, the acceleration mode transitions to the deflagration mode type found in the quasi-steady MPD thrusters. This modeling method is used to demonstrate that standard gas-fed pulsed plasma accelerators, the CHENG thruster, and the quasi-steady MPD accelerator are variations of the same device, with the overall acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

  20. Supression of laser breakdown by pulsed nonequilibrium ns discharge

    NASA Astrophysics Data System (ADS)

    Starikovskiy, A. Y.; Semenov, I. E.; Shneider, M. N.

    2016-10-01

    The avalanche ionization induced by infrared laser pulses was investigated in a pre-ionized argon gas. Pre-ionization was created by a high-voltage pulsed nanosecond discharge developed in the form of a fast ionization wave. Then, behind the front of ionization wave additional avalanche ionization was initiated by the focused Nd-YAG laser pulse. It was shown that the gas pre-ionization inhibits the laser spark generation. It was demonstrated that the suppression of laser spark development in the case of strong gas pre-ionization is because of fast electron energy transfer from the laser beam focal region. The main mechanism of this energy transfer is free electrons diffusion.

  1. Role of electric discharges in the generation of atmospheric vortices

    NASA Astrophysics Data System (ADS)

    Sinkevich, O. A.; Maslov, S. A.; Gusein-zade, N. G.

    2017-02-01

    The existing thermohydrodynamic and hydroelectromagnetic models of tornado are considered. The potentialities of the humid atmosphere as a heat engine generating air vortices are analyzed in detail. The ability of long-term atmospheric electric discharges to form a tornado funnel and create an initial twist of up to 10-3-10-2 s-1 in it are estimated. The possible effect of a lightning discharge on the initiation and evolution of the tornado is discussed. It is shown that the electric current flowing along the lightning channel can lead to helical instability and generation of a weak primary vortex. The channel formed in the atmosphere by a lightning discharge and the vortex motion of the parent thundercloud can enhance the primary vortex and promote its transformation into a tornado. Possible mechanisms of enhancement of the primary vortex created by a lightning discharge and the possibility of its transformation into a tornado in the postdischarge stage are discussed.

  2. The channel radius and energy of cloud-to-ground lightning discharge plasma with multiple return strokes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xuejuan; Yuan, Ping; Cen, Jianyong

    2014-03-15

    Using the spectra of a cloud-to-ground (CG) lightning flash with multiple return strokes and combining with the synchronous radiated electrical field information, the linear charge density, the channel radius, the energy per unit length, the thermal energy, and the energy of dissociation and ionization in discharge channel are calculated with the aid of an electrodynamic model of lightning. The conclusion that the initial radius of discharge channel is determined by the duration of the discharge current is confirmed. Moreover, the correlativity of several parameters has been analyzed first. The results indicate that the total intensity of spectra is positive correlatedmore » to the channel initial radius. The ionization and thermal energies have a linear relationship, and the dissociation energy is correlated positively to the ionization and thermal energies, the energy per unit length is in direct proportion to the square of initial radius in different strokes of one CG lightning.« less

  3. EXPERT SYSTEMS FOR MIXING-ZONE ANALYSIS AND DESIGN OF POLLUTANT DISCHARGES

    EPA Science Inventory

    Water-quality policy in the United States includes the concept of a mixing zone, a limited area or volume of water where initial dilution of an aqueous pollutant discharge occurs. iven a myriad of possible discharge configurations, ambient environments, and mixing zone definition...

  4. On the shape of the glow discharge channel

    NASA Astrophysics Data System (ADS)

    Dmitriev, A. L.; Nikushchenko, E. M.

    2017-05-01

    Examples of the shapes of the glow discharge channel are presented. The discharge has been initiated in air at a pressure of 0.1 atm. The effective value and frequency of the discharge current are 30-70 mA and 50 Hz, respectively. It has been shown that, for these values of the current and pressure, thermal convection in a vacuum chamber and buoyancy (Archimedes force) are not major reasons for the specific parabolic shape of glow discharge.

  5. Polydopamine and MnO2 core-shell composites for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Hou, Ding; Tao, Haisheng; Zhu, Xuezhen; Li, Maoguo

    2017-10-01

    Polydopamine and MnO2 core-shell composites (PDA@MnO2) for high-performance supercapacitors had been successfully synthesized by a facile and fast method. The morphology, crystalline phase and chemical composition of PDA@MnO2 composites are characterized using SEM, TEM, XRD, EDS and XPS. The performance of PDA@MnO2 composites are further investigated by cyclic voltammetry, galvanostatic charge-discharge and electrochemical impedance spectroscopy in 1 M Na2SO4 electrolyte. The PDA@MnO2 core-shell nanostructure composites exhibit a high capacitance of 193 F g-1 at the current density of 1A g-1 and retained over 81.2% of its initial capacitance after 2500 cycles of charge-discharge at 2 A g-1. The results manifest that the PDA@MnO2 composites can be potentially applied in supercapacitors.

  6. Plasma channel optical pumping device and method

    DOEpatents

    Judd, O.P.

    1983-06-28

    A device and method are disclosed for optically pumping a gaseous laser using blackbody radiation produced by a plasma channel which is formed from an electrical discharge between two electrodes spaced at opposite longitudinal ends of the laser. A preionization device which can comprise a laser or electron beam accelerator produces a preionization beam which is sufficient to cause an electrical discharge between the electrodes to initiate the plasma channel along the preionization path. The optical pumping energy is supplied by a high voltage power supply rather than by the preionization beam. High output optical intensities are produced by the laser due to the high temperature blackbody radiation produced by the plasma channel, in the same manner as an exploding wire type laser. However, unlike the exploding wire type laser, the disclosed invention can be operated in a repetitive manner by utilizing a repetitive pulsed preionization device. 5 figs.

  7. Algebraic method for parameter identification of circuit models for batteries under non-zero initial condition

    NASA Astrophysics Data System (ADS)

    Devarakonda, Lalitha; Hu, Tingshu

    2014-12-01

    This paper presents an algebraic method for parameter identification of Thevenin's equivalent circuit models for batteries under non-zero initial condition. In traditional methods, it was assumed that all capacitor voltages have zero initial conditions at the beginning of each charging/discharging test. This would require a long rest time between two tests, leading to very lengthy tests for a charging/discharging cycle. In this paper, we propose an algebraic method which can extract the circuit parameters together with initial conditions. This would theoretically reduce the rest time to 0 and substantially accelerate the testing cycles.

  8. Development of a High Efficiency Compressor/Expander for an Air Cycle Air Conditioning System.

    DTIC Science & Technology

    1982-11-15

    bearing, lb PHUB - Hub pressure (initial guess), psia RLG - Rotor length 1 ’B-2 RPM - Rotational speed, RPM R - Gas constant, lb -ft/lb - R CP - Specific...Compressor discharge port pressure ratio (PCD/PC2).:- CDP - Compressor pressure change, PCD-PCl PHUB - Pressure in compressor hub (acting on base of vanes

  9. High surface area LaMnO3 nanoparticles enhancing electrochemical catalytic activity for rechargeable lithium-air batteries

    NASA Astrophysics Data System (ADS)

    Li, Chuanhua; Yu, Zhiyong; Liu, Hanxing; Chen, Kang

    2018-02-01

    To improve sluggish kinetics of ORR and OER (oxygen reduction and evolution reaction) on the air electrode, the high surface area LaMnO3 nanoparticle catalysts were synthesized by sol-gel method. The specific surface area of as-synthesized pure phase LaMnO3 nanoparticles is 21.21 m2 g-1. The onset potential of high surface area LaMnO3 in alkaline solution is -0.0202 V which is comparable to commercial Pt/C. When the assembled high surface area LaMnO3-based lithium-air batteries were measured at 100 mA g-1, the initial discharge specific capacity could reach 6851.9 mA h g-1(carbon). In addition, lithium-oxygen batteries including high surface area LaMnO3 catalysts could be cycled for 52 cycles at 200 mA g-1 under a limited discharge-charge depth of 500 mA h gcarbon-1.

  10. Modelling of streamer ignition and propagation in the system of two approaching hydrometeors

    NASA Astrophysics Data System (ADS)

    Jansky, J.; Pasko, V. P.

    2017-12-01

    The lightning initiation in low thundercloud fields represents an unsolved problem in lightning discharge physics. One of the initial conditions required for formation of a hot leader channel is initiation of non-thermal streamer discharges. Streamers can be initiated from electron avalanches, however, the problem of existence of an electric field strong enough for streamer initiation in thunderclouds is still open. The maximum electric field in thunderstorms measured by balloons is typically 3-4 kV cm-1 atm-1, that is significantly smaller than the breakdown electric field needed for avalanche multiplication of electrons Ek≃28.7 kV cm-1 atm-1. One of the possible explanations for the streamer corona initiation is that hydrometeors greatly intensify the local electric field by at least an order of magnitude to initiate an electron avalanche. It was suggested that a particle pair or chain create more favorable conditions for initiation of lightning discharge than a single precipitation particle in low electric fields. Recently Cai et al. [GRL, 44, 5758-5765, 2017] analyzed the ignition conditions for two hydrometeors of same radii. In the present work we use streamer fluid model to study streamer initiation scenarios in a system of two hydrometeors with different radii. When the hydrometeors are approaching the Townsend discharge may develop first between them. Then the Townsend discharge transforms to streamer and two hydrometeors connect electrically, which leads to increase of the electric field on the outside hemispheres of hydrometeors. This increase of field for two particles of same radii was analyzed by Cooray et al. [Proceedings of 24th International Conference on Lightning Protection, Birmingham, United Kingdom, 1998]. The combination of small and large hydrometeors leads to higher enhancement on the outside of small hydrometeor. Simulation results show that streamer ignites there and propagates away from two hydrometeors. The streamer ignites at fields below Meek criterion due to the effects of photoionization feedback [Naidis, JPD, 38, 2211-2214, 2005; Liu et al., JASTP, 80, 179-186, 2012].

  11. Development of a ROV Deployed Video Analysis Tool for Rapid Measurement of Submerged Oil/Gas Leaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savas, Omer

    Expanded deep sea drilling around the globe makes it necessary to have readily available tools to quickly and accurately measure discharge rates from accidental submerged oil/gas leak jets for the first responders to deploy adequate resources for containment. We have developed and tested a field deployable video analysis software package which is able to provide in the field sufficiently accurate flow rate estimates for initial responders in accidental oil discharges in submarine operations. The essence of our approach is based on tracking coherent features at the interface in the near field of immiscible turbulent jets. The software package, UCB_Plume, ismore » ready to be used by the first responders for field implementation. We have tested the tool on submerged water and oil jets which are made visible using fluorescent dyes. We have been able to estimate the discharge rate within 20% accuracy. A high end WINDOWS laptop computer is suggested as the operating platform and a USB connected high speed, high resolution monochrome camera as the imaging device are sufficient for acquiring flow images under continuous unidirectional illumination and running the software in the field. Results are obtained over a matter of minutes.« less

  12. Theta-Pinch Thruster for Piloted Deep Space Exploration

    NASA Technical Reports Server (NTRS)

    LaPointe, Mike R.; Reddy, Dhanireddy (Technical Monitor)

    2000-01-01

    A new high-power propulsion concept that combines a rapidly pulsed theta-pinch discharge with upstream particle reflection by a magnetic mirror was evaluated under a Phase 1 grant awarded through the NASA Institute for Advanced Concepts. Analytic and numerical models were developed to predict the performance of a theta-pinch thruster operated over a wide range of initial gas pressures and discharge periods. The models indicate that a 1 m radius, 10 m long thruster operated with hydrogen propellant could provide impulse-bits ranging from 1 N-s to 330 N-s with specific impulse values of 7,500 s to 2,500 s, respectively. A pulsed magnetic field strength of 2 T is required to compress and heat the preionized hydrogen over a 10(exp -3) second discharge period, with about 60% of the heated plasma exiting the chamber each period to produce thrust. The unoptimized thruster efficiency is low, peaking at approximately 16% for an initial hydrogen chamber pressure of 100 Torr. The specific impulse and impulse-bit at this operating condition are 3,500 s and 90 N-s, respectively, and the required discharge energy is approximately 9x10(exp 6) J. For a pulse repetition rate of 10 Hz, the engine would produce an average thrust of 900 N at 3,500 s specific impulse. Combined with the electrodeless nature of the device, these performance parameters indicate that theta-pinch thrusters could provide unique, long-life propulsion systems for piloted deep space mission applications.

  13. Investigation of capillary nanosecond discharges in air at moderate pressure: comparison of experiments and 2D numerical modelling

    NASA Astrophysics Data System (ADS)

    Klochko, Andrei V.; Starikovskaia, Svetlana M.; Xiong, Zhongmin; Kushner, Mark J.

    2014-09-01

    Nanosecond electrical discharges in the form of ionization waves are of interest for rapidly ionizing and exciting complex gas mixtures to initiate chemical reactions. Operating with a small discharge tube diameter can significantly increase the specific energy deposition and so enable optimization of the initiation process. Analysis of the uniformity of energy release in small diameter capillary tubes will aid in this optimization. In this paper, results for the experimentally derived characteristics of nanosecond capillary discharges in air at moderate pressure are presented and compared with results from a two-dimensional model. The quartz capillary tube, having inner and outer diameters of 1.5 and 3.4 mm, is about 80 mm long and filled with synthetic dry air at 27 mbar. The capillary tube with two electrodes at the ends is inserted into a break of the central wire of a long coaxial cable. A metal screen around the tube is connected to the cable ground shield. The discharge is driven by a 19 kV 35 ns voltage pulse applied to the powered electrode. The experimental measurements are conducted primarily by using a calibrated capacitive probe and back current shunts. The numerical modelling focuses on the fast ionization wave (FIW) and the plasma properties in the immediate afterglow after the conductive plasma channel has been established between the two electrodes. The FIW produces a highly focused region of electric field on the tube axis that sustains the ionization wave that eventually bridges the electrode gap. Results from the model predict FIW propagation speed and current rise time that agree with the experiment.

  14. Glucose-assisted synthesis of Na3V2(PO4)3/C composite as an electrode material for high-performance sodium-ion batteries

    NASA Astrophysics Data System (ADS)

    Li, Guangqiang; Jiang, Danlu; Wang, Hui; Lan, Xinzheng; Zhong, Honghai; Jiang, Yang

    2014-11-01

    A novel electrode material for sodium-ion batteries (NIBs), Na3V2(PO4)3 with a rhombohedral, Na+ superionic conductor (NASICON)-type structure, was synthesised via a solid-state carbon-thermal reduction reaction assisted by mechanochemical activation. Electron microscopy analysis showed that the synthesised Na3V2(PO4)3 particles had an average size of 300 nm, being coated with a uniform layer of carbon 3 nm in thickness. As a cathode material, Na3V2(PO4)3/C exhibited an initial specific discharge capacity of 98.17 mAh g-1 at 0.1C for potentials ranging from 2.5 to 3.8 V. This was owing to the V3+/V4+ redox couple, which corresponded to the two-phase transition between Na3V2(PO4)3 and NaV2(PO4)3. The cathode lost 4.92% of its discharge specific capacity after 50 cycles. As an anode material, Na3V2(PO4)3/C exhibited an initial specific discharge capacity of 63.2 mAh g-1 at 0.1C for potentials ranging from 1.0 to 2.5 V. This was owing to the V2+/V3+ redox couple, which corresponded to the two-phase transition between Na3V2(PO4)3 and Na4V2(PO4)3. The anode lost approximately 5.41% of its discharge specific capacity after 50 cycles. The three-dimensional channel structure of NaV2(PO4)3 and the changes induced in its lattice parameters during the charge/discharge processes were simulated on the basis of density functional theory.

  15. How Do River Meanders Change with Sea Level Rise and Fall?

    NASA Astrophysics Data System (ADS)

    Scamardo, J. E.; Kim, W.

    2016-12-01

    River meander patterns are controlled by numerous factors, including variations in water discharge, sediment input, and base level. However, the effect of sea level rise and fall on meandering rivers has not been thoroughly quantified. This study examines geomorphic changes to meandering rivers as a result of sea level rise and fall. Twenty experimental runs using coarse-grained walnut shell sediment (D50= 500 microns) in a flume tank (2.4m x 0.6m x 0.1m) tested the optimal initial conditions for creating meandering rivers in a laboratory setting as well as variations in base level rise and fall rates. Geomorphic changes were recorded by camera images every 20 seconds for a duration of 4 hours per experiment. Seventeen experiments tested the effects of changes in initial base levels, water discharge between 200 and 400 mL/min, and sediment to water input ratios between 1:1000 and 1:250 while measuring sinuosity, channel geometry, and the timescale of the channel to reach a stable form. Sinuosity and channel activity increased with increasing water discharge, initial base level, and the sediment to water ratio to a point after which the activity decreased with increasing sediment input. Base-level change experiments used initial conditions of 400 mL/min, a 1:750 sediment to water input ratio, and a 6 cm initial base-level to induce river meanders for the initial 2 hours before base-level change occurred. Three separate experiments investigated the effects of increasing rates of sea level change: 0.07 cm/min, 0.1 cm/min, and 0.2 cm/min. Experimental sea level was decreased constantly from a high-stand of 6 cm to a low-stand of 2 cm back to the high-stand base-level in each experiment. The rates of change in the experiments scale roughly from central to glacial cycles. In all three experiments, sea level fall induced meander cut-off while sea level rise prompted greater rates of meander bend erosion and meander growth. Sinuosity increased by 12%, 13.5%, and 24%, respectively in the three experiments, with most sinuosity changes occurring in the downstream reach of the channel. These experiments could provide insight into long term effects of sea level change on modern meandering fluvial systems as well as provide a key to interpreting past fluvial changes in the stratigraphic record.

  16. A relationship between a level of hemoglobin after delivery and exclusive breastfeeding initiation at a baby friendly hospital in Japan.

    PubMed

    Horie, Saki; Nomura, Kyoko; Takenoshita, Shinichi; Nakagawa, Junko; Kido, Michiko; Sugimoto, Mitsuhiro

    2017-04-20

    The recent National Nutrition Survey of 2013 demonstrated that 16.7% of women in childbearing age are underweight, and 5.0-10.0% of these women manifested a Hemoglobin (Hb) level less than 11.0 g/dl. The purpose of this study was to investigate if such maternal nutritional status affects success of exclusive breastfeeding (EBF) practice. This cross-sectional study investigated 1532 dyads of mothers and infants with full-term singleton pregnancies delivered during 2011 at a perinatal center in Tokyo. Outcome is EBF initiation defined as the successful practice at discharge and 1 month after discharge. A logistic regression model was applied to investigate the impact of Hb levels (<9.0, 9.0-10.9, and ≥11.0 g/dl) measured within 2-3 days after delivery on successful EBF initiation adjusting for covariates including bleeding at delivery. Mean age was 34 years, 23.0% were underweight and 63.0% were nulliparous. The success rate for EBF initiation at discharge and at 1 month after discharge was 72.7 and 63.0% for a Hb level <9.0 g/dl, 81.9 and 68.9% for a Hb level of 9.0-10.9 g/dl, and 85.7 and 75.9% for a Hb level ≥11.0 g/dl, respectively. A logistic regression model showed that risk factors of unsuccessful EBF practice at discharge and 1 month after discharge included lower level Hb categories (P < 0.001 and P < 0.001), postpartum hemorrhage > 500 ml (P = 0.089 and P = 0.011), maternal age (P < 0.001 and P < 0.001), nulliparity (P < 0.0001 and P < 0.001), pregnancy-induced hypertension (P = 0.002 and P = 0.012), gestational week (P = 0.006 and P = 0.002), Low Birth Weight (LBW) (P < 0.001 and P < 0.001), and immediate separation (P < 0.001 and P = 0.020). After adjusting for the covariates, compared with a Hb level ≥11.0 g/dl, a Hb level <9.0 g/dl was significantly associated with unsuccessful EBF initiation at discharge [odds ratio (OR): 2.15; 95% confidence interval (CI): 1.37-3.39] and at 1 month after discharge (OR: 1.63; 95% CI: 1.10-2.42), and a Hb level of 9.0-10.9 g/dl also was significant at 1 month after discharge (OR: 1.35; 95% CI: 1.04-1.75). Pre-pregnancy underweight was not associated with success of EBF practice both at hospital discharge and 1 month after discharge. Maternal severe anemia after delivery was associated with the risk of unsuccessful initiation of EBF even after adjusting for bleeding at delivery, suggesting the importance of dietary management especially in the later trimester.

  17. Numerical simulation of narrow bipolar electromagnetic pulses generated by thunderstorm discharges

    NASA Astrophysics Data System (ADS)

    Bochkov, E. I.; Babich, L. P.; Kutsyk, I. M.

    2013-07-01

    Using the concept of avalanche relativistic runaway electrons (REs), we perform numerical simulations of compact intracloud discharge (CID) as a generator of powerful natural electromagnetic pulses (EMPs) in the HF-VHF range, called narrow bipolar pulses (NBPs). For several values of the field overvoltage and altitude at which the discharge develops, the numbers of seed electrons initiating the avalanche are evaluated, with which the calculated EMP characteristics are consistent with the measured NBP parameters. We note shortcomings in the hypothesis assuming participation of cosmic ray air showers in avalanche initiation. The discharge capable of generating NBPs produces REs in numbers close to those in the source of terrestrial γ-ray flashes (TGFs), which can be an argument in favor of a unified NBP and TGF source.

  18. Intense Femtosecond Laser-Mediated Electrical Discharge Enables Preparation of Amorphous Nickel Phosphide Nanoparticles.

    PubMed

    Ma, Zhuo-Chen; Chen, Qi-Dai; Han, Bing; Li, He-Long; Wang, Lei; Zhang, Yong-Lai; Sun, Hong-Bo

    2018-05-09

    Reported here is a high-efficiency preparation method of amorphous nickel phosphide (Ni-P) nanoparticles by intense femtosecond laser irradiation of nickel sulfate and sodium hypophosphite aqueous solution. The underlying mechanism of the laser-assisted preparation was discussed in terms of the breaking of chemical bond in reactants via highly intense electric field discharge generated by the intense femtosecond laser. The morphology and size of the nanoparticles can be tuned by varying the reaction parameters such as ion concentration, ion molar ratio, laser power, and irradiation time. X-ray diffraction and transmission electron microscopy results demonstrated that the nanoparticles were amorphous. Finally, the thermogravimetric-differential thermal analysis experiment verified that the as-synthesized noncrystalline Ni-P nanoparticles had an excellent catalytic capability toward thermal decomposition of ammonium perchlorate. This strategy of laser-mediated electrical discharge under such an extremely intense field may create new opportunities for the decomposition of molecules or chemical bonds that could further facilitate the recombination of new atoms or chemical groups, thus bringing about new possibilities for chemical reaction initiation and nanomaterial synthesis that may not be realized under normal conditions.

  19. Time resolved EUV spectra from Zpinching capillary discharge plasma

    NASA Astrophysics Data System (ADS)

    Jancarek, Alexandr; Nevrkla, Michal; Nawaz, Fahad

    2015-09-01

    We developed symmetrically charged driver to obtain high voltage, high current Z-pinching capillary discharge. Plasma is created by up to 70 kA, 29 ns risetime current pulse passing through a 5 mm inner diameter, 224 mm long capillary filled with gas to initial pressure in the range of 1 kPa. Due to the low inductance design of the driver, the pinch is observable directly from the measured current curve. Time-integrated and time-resolved spectra of discharge plasma radiation are recorded together with the capillary current and analyzed. The most encouraging spectra were captured in the wavelength range 8.3 ÷ 14 nm. This spectral region contains nitrogen Balmer series lines including potentially lasing NVII 2 - 3 transition. Spectral lines are identified in the NIST database using the FLY kinetic code. The line of 13.38 nm wavelength, transition NVII 2 - 3, was observed in gated, and also in time-integrated spectra for currents >60 kA. This work has been supported by the Ministry of Education, Youth and Sports of the Czech Republic grants LG13029.

  20. Synthesis of fcc Mg-Ti-H alloys by high energy ball milling: Structure and electrochemical hydrogen storage properties

    NASA Astrophysics Data System (ADS)

    Rousselot, Steeve; Guay, Daniel; Roué, Lionel

    Mg-Ti-H alloys were synthesized by high energy ball milling from equimolar mixtures of MgH 2 + TiH 2, MgH 2 + Ti and Mg + TiH 2 in the presence of 10 wt.% Pd. X-ray diffraction analyses combined with Rietveld refinement revealed that after 60 h of milling, all as-milled Mg-Ti-H alloys are made of two face-centered-cubic (fcc) phases, with lattice parameters ∼4.47 and ∼4.25 Å, in different proportions depending on the composition of the initial mixture. The Mg-Ti-H alloys displayed a similar electrochemical behavior, i.e. their hydrogen discharge capacity was highest during the first cycle and then decreased rapidly with cycling. The maximum discharge capacities of the 60 h-milled MgH 2 + TiH 2, MgH 2 + Ti and Mg + TiH 2 materials were 300, 443 and 454 mAh g -1, respectively. No apparent correlation could be established between the maximum discharge capacity of the Mg-Ti-H materials and the two fcc phase proportion.

  1. Enhanced electrochemical performance of a ZnO-MnO composite as an anode material for lithium ion batteries.

    PubMed

    Song, Min Seob; Nahm, Sahn; Cho, Won Il; Lee, Chongmok

    2015-09-28

    A ZnO-MnO composite was synthesized using a simple solvothermal method combined with a high-temperature treatment. To observe the phase change during the heating process, in situ high-temperature XRD analysis was performed under vacuum conditions. The results indicated that ZnMn2O4 transformed into the ZnO-MnO composite phase starting from 500 °C and that this composite structure was retained until 700 °C. The electrochemical performances of the ZnO-MnO composite electrode were evaluated through galvanostatic discharge-charge tests and cyclic voltammetry analysis. Its initial coulombic efficiency was significantly improved to 68.3% compared to that of ZnMn2O4 at 54.7%. Furthermore, the ZnO-MnO composite exhibited improved cycling performance and enhanced rate capability compared with untreated ZnMn2O4. To clarify the discharge-charge mechanism of the ZnO-MnO composite electrode, the structural changes during the charge and discharge processes were also investigated using ex situ XRD and TEM.

  2. Magneto-hydrodynamic modeling of gas discharge switches

    NASA Astrophysics Data System (ADS)

    Doiphode, P.; Sakthivel, N.; Sarkar, P.; Chaturvedi, S.

    2002-12-01

    We have performed one-dimensional, time-dependent magneto-hydrodynamic modeling of fast gas-discharge switches. The model has been applied to both high- and low-pressure switches, involving a cylindrical argon-filled cavity. It is assumed that the discharge is initiated in a small channel near the axis of the cylinder. Joule heating in this channel rapidly raises its temperature and pressure. This drives a radial shock wave that heats and ionizes the surrounding low-temperature region, resulting in progressive expansion of the current channel. Our model is able to reproduce this expansion. However, significant difference of detail is observed, as compared with a simple model reported in the literature. In this paper, we present details of our simulations, a comparison with results from the simple model, and a physical interpretation for these differences. This is a first step towards development of a detailed 2-D model for such switches.

  3. Macroparticle generation in DC arc discharge from a WC cathode

    NASA Astrophysics Data System (ADS)

    Zhirkov, Igor; Polcik, Peter; Kolozsvári, Szilard; Rosen, Johanna

    2017-03-01

    We have studied macroparticle generation from a tungsten carbide cathode used in a dc vacuum arc discharge. Despite a relatively high decomposition/melting point (˜3100 K), there is an intensive generation of visible particles with sizes in the range 20-35 μm. Visual observations during the discharge and scanning electron microscopy of the cathode surface and of collected macroparticles indicate a new mechanism for particle formation and acceleration. Based on the W-C phase diagram, there is an intensive sublimation of carbon from the melt resulting from the cathode spot. The sublimation supports the formation of a sphere, which is accelerated upon an explosion initiated by Joule heating at the critical contact area between the sphere and the cathode body. The explosive nature of the particle acceleration is confirmed by surface features resembling the remains of a splash on the droplet surface.

  4. Extremely Stable Polypyrrole Achieved via Molecular Ordering for Highly Flexible Supercapacitors.

    PubMed

    Huang, Yan; Zhu, Minshen; Pei, Zengxia; Huang, Yang; Geng, Huiyuan; Zhi, Chunyi

    2016-01-27

    The cycling stability of flexible supercapacitors with conducting polymers as electrodes is limited by the structural breakdown arising from repetitive counterion flow during charging/discharging. Supercapacitors made of facilely electropolymerized polypyrrole (e-PPy) have ultrahigh capacitance retentions of more than 97, 91, and 86% after 15000, 50000, and 100000 charging/discharging cycles, respectively, and can sustain more than 230000 charging/discharging cycles with still approximately half of the initial capacitance retained. To the best of our knowledge, such excellent long-term cycling stability was never reported. The fully controllable electropolymerization shows superiority in molecular ordering, favoring uniform stress distribution and charge transfer. Being left at ambient conditions for even 8 months, e-PPy supercapacitors completely retain the good electrochemical performance. The extremely stable supercapacitors with excellent flexibility and scalability hold considerable promise for the commerical application of flexible and wearable electronics.

  5. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Laser-induced extreme UV radiation sources for manufacturing next-generation integrated circuits

    NASA Astrophysics Data System (ADS)

    Borisov, V. M.; Vinokhodov, A. Yu; Ivanov, A. S.; Kiryukhin, Yu B.; Mishchenko, V. A.; Prokof'ev, A. V.; Khristoforov, O. B.

    2009-10-01

    The development of high-power discharge sources emitting in the 13.5±0.135-nm spectral band is of current interest because they are promising for applications in industrial EUV (extreme ultraviolet) lithography for manufacturing integrated circuits according to technological precision standards of 22 nm and smaller. The parameters of EUV sources based on a laser-induced discharge in tin vapours between rotating disc electrodes are investigated. The properties of the discharge initiation by laser radiation at different wavelengths are established and the laser pulse parameters providing the maximum energy characteristics of the EUV source are determined. The EUV source developed in the study emits an average power of 276 W in the 13.5±0.135-nm spectral band on conversion to the solid angle 2π sr in the stationary regime at a pulse repetition rate of 3000 Hz.

  6. A sensitive gas chromatography detector based on atmospheric pressure chemical ionization by a dielectric barrier discharge.

    PubMed

    Kirk, Ansgar T; Last, Torben; Zimmermann, Stefan

    2017-02-03

    In this work, we present a novel concept for a gas chromatography detector utilizing an atmospheric pressure chemical ionization which is initialized by a dielectric barrier discharge. In general, such a detector can be simple and low-cost, while achieving extremely good limits of detection. However, it is non-selective apart from the use of chemical dopants. Here, a demonstrator manufactured entirely from fused silica capillaries and printed circuit boards is shown. It has a size of 75×60×25mm 3 and utilizes only 2W of power in total. Unlike other known discharge detectors, which require high-purity helium, this detector can theoretically be operated using any gas able to form stable ion species. Here, purified air is used. With this setup, limits of detection in the low parts-per-billion range have been obtained for acetone. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Accidental Turbulent Discharge Rate Estimation from Videos

    NASA Astrophysics Data System (ADS)

    Ibarra, Eric; Shaffer, Franklin; Savaş, Ömer

    2015-11-01

    A technique to estimate the volumetric discharge rate in accidental oil releases using high speed video streams is described. The essence of the method is similar to PIV processing, however the cross correlation is carried out on the visible features of the efflux, which are usually turbulent, opaque and immiscible. The key step in the process is to perform a pixelwise time filtering on the video stream, in which the parameters are commensurate with the scales of the large eddies. The velocity field extracted from the shell of visible features is then used to construct an approximate velocity profile within the discharge. The technique has been tested on laboratory experiments using both water and oil jets at Re ~105 . The technique is accurate to 20%, which is sufficient for initial responders to deploy adequate resources for containment. The software package requires minimal user input and is intended for deployment on an ROV in the field. Supported by DOI via NETL.

  8. Atmospheric-pressure electric discharge as an instrument of chemical activation of water solutions

    NASA Astrophysics Data System (ADS)

    Rybkin, V. V.; Shutov, D. A.

    2017-11-01

    Results of experimental studies and numerical simulations of physicochemical characteristics of plasmas generated in different types of atmospheric-pressure discharges (pulsed streamer corona, gliding electric arc, dielectric barrier discharge, glow-discharge electrolysis, diaphragmatic discharge, and dc glow discharge) used to initiate various chemical processes in water solutions are analyzed. Typical reactor designs are considered. Data on the power supply characteristics, plasma electron parameters, gas temperatures, and densities of active particles in different types of discharges excited in different gases and their dependences on the external parameters of discharges are presented. The chemical composition of active particles formed in water is described. Possible mechanisms of production and loss of plasma particles are discussed.

  9. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    NASA Astrophysics Data System (ADS)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  10. Investigation of a single barrier discharge in submillimeter air gaps. Nonuniform field

    NASA Astrophysics Data System (ADS)

    Bondarenko, P. N.; Emel'yanov, O. A.; Shemet, M. V.

    2014-08-01

    Pulse characteristics of single barrier discharges as well as parameters of charges accumulated on the surface of a dielectric under the atmospheric pressure in the "needle-(0.1-2.0)-mm air gap-polymer barrier-plane" system are investigated. It is found experimentally that for the positive polarity of the needle, the voltage for the discharge initiation is higher than in the case of the negative polarity by ˜25-35%. The reversal of the needle polarity from negative to positive increases the amplitude of the discharge current and the accumulated surface charge by ˜1.5-3 times. For the positive polarity of the needle, the discharge is governed by a streamer mechanism, while for the negative polarity, the discharge is initiated by the formation of a single Trichel pulse. The single pulse regime is observed for the discharge current up to a certain electrode gap d CR. For the positive needle and for air gap width d air > d CR ≈ 1.5 mm, a multipulse burst corona is formed, while for the negative needle and d air > d CR ≈ 0.9 mm, a damped sequence of Trichel pulses evolves in the system.

  11. Effectiveness of granisetron in controlling pediatric gastroenteritis-related vomiting after discharge from the ED.

    PubMed

    Qazi, Khajista; BinSalleeh, Hashim M; Shah, Ubaid H; AlGhamedi, Najwa; Tamim, Hani; Mubasher, Mohamed; Alrasheed, Faris; Alkanhal, Abdulrahman; AlTamimi, Saleh A

    2014-09-01

    The objective of the study is to determine the efficacy of oral granisetron (a long-acting 5-HT3 receptor antagonist) in stopping vomiting subsequent to discharge from emergency department (ED), in 6-month-old to 8-year-old patients with gastroenteritis-related vomiting and dehydration, who had failed an initial trial of oral rehydration (ORT). Eligible patients were offered ORT on a slowly advancing schedule. Patients who tolerated the initial ORT were discharged home. Patients who vomited were randomized to receive either 40 μg/kg of granisetron or placebo, and ORT was resumed. Patients who tolerated the postrandomization ORT were discharged home with another dose of the study drug. Parents were contacted by telephone every 24 hours until complete resolution of symptoms. The primary outcome was the proportion of patients with vomiting at 24 hours. Of the 900 eligible patients, 537 (60%) tolerated the initial ORT and were discharged home. Of the patients who vomited during the initial ORT, 165 were included in the final study sample (placebo, n = 82; granisetron, n = 83). There was no statistically significant difference in the proportion of patients with vomiting at 24 hours (granisetron, n = 38; placebo, n = 45; odds ratio, 0.64; 95% confidence interval, 0.34-1.19; P = .16). A similar trend in the proportion of patients with vomiting was noted for the entire follow-up period (granisetron, n = 43; placebo, n = 47; odds ratio, 0.73; P = .33; 95% confidence interval, 0.39-1.36). Granisetron was not effective in controlling gastroenteritis-related vomiting subsequent to discharge from ED. It did not change the expected course of the illness. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Maternal Education Is Associated with Disparities in Breastfeeding at Time of Discharge but Not at Initiation of Enteral Feeding in the Neonatal Intensive Care Unit.

    PubMed

    Herich, Lena Carolin; Cuttini, Marina; Croci, Ileana; Franco, Francesco; Di Lallo, Domenico; Baronciani, Dante; Fares, Katia; Gargano, Giancarlo; Raponi, Massimiliano; Zeitlin, Jennifer

    2017-03-01

    To investigate the relationship between maternal education and breastfeeding in very preterm infants admitted to neonatal intensive care units. This prospective, population-based cohort study analyzed the data of all very preterm infants admitted to neonatal care during 1 year in 3 regions in Italy (Lazio, Emilia-Romagna, and Marche). The use of mothers' own milk was recorded at initial enteral feedings and at hospital discharge. We used multilevel logistic analysis to model the association between maternal education and breastfeeding outcomes, adjusting for maternal age and country of birth. Region was included as random effect. There were 1047 very preterm infants who received enteral feeding, and 975 were discharged alive. At discharge, the use of mother's own milk, exclusively or not, and feeding directly at the breast were significantly more likely for mothers with an upper secondary education or higher. We found no relationship between maternal education and type of milk at initial enteral feedings. However, the exclusive early use of the mother's own milk at initial feedings was related significantly with receiving any maternal milk and feeding directly at the breast at discharge from hospital, and the association with feeding at the breast was stronger for the least educated mothers. In this population-based cohort of very preterm infants, we found a significant and positive association between maternal education and the likelihood of receiving their mother's own milk at the time of discharge. In light of the proven benefits of maternal milk, strategies to support breastfeeding should be targeted to mothers with less education. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Plasma Discharge Initiation of Explosives in Rock Blasting Application: A Case Study

    NASA Astrophysics Data System (ADS)

    Jae-Ou, Chae; Young-Jun, Jeong; V, M. Shmelev; A, A. Denicaev; V, M. Poutchkov; V, Ravi

    2006-07-01

    A plasma discharge initiation system for the explosive volumetric combustion charge was designed, investigated and developed for practical application. Laboratory scale experiments were carried out before conducting the large scale field tests. The resultant explosions gave rise to less noise, insignificant seismic vibrations and good specific explosive consumption for rock blasting. Importantly, the technique was found to be safe and environmentally friendly.

  14. Factors associated with initiation and exclusive breastfeeding at hospital discharge: late preterm compared to 37 week gestation mother and infant cohort.

    PubMed

    Ayton, Jennifer; Hansen, Emily; Quinn, Stephen; Nelson, Mark

    2012-11-26

    To investigate and examine the factors associated with initiation of, and exclusive breastfeeding at hospital discharge of, late preterm (34 0/7 - 36 6/7 weeks) compared to 37 week gestation (37 0/7 - 37 6/7 week) mother and baby pairs. A retrospective population-based cohort study using a Perinatal National Minimum Data Set and clinical medical records review, at the Royal Hobart Hospital, Tasmania, Australia in 2006. Late preterm and 37 week gestation infants had low rates of initiation of breastfeeding within one hour of birth, 31 (21.1%) and 61 (41.5%) respectively. After multiple regression analysis, late preterm infants were less likely to initiate breastfeeding within one hour of birth (OR 0.3 95% CI 0.1, 0.7 p = 0.009) and were less likely to be discharged exclusively breastfeeding from hospital (OR 0.4 95% CI 0.1, 1.0 p = 0.04) compared to 37 week gestation infants. A late preterm birth is predictive of breastfeeding failure, with late preterm infants at greater risk of not initiating breastfeeding and/or exclusively breastfeeding at hospital discharge, compared with those infants born at 37 weeks gestation. Stratifying breastfeeding outcomes by gestational age groups may help to identify those sub-populations at greatest risk of premature cessation of breastfeeding.

  15. Daily GRACE storage anomaly data for characterization of dynamic storage-discharge relationships of natural drainage basins

    NASA Astrophysics Data System (ADS)

    Sharma, D.; Patnaik, S.; Reager, J. T., II; Biswal, B.

    2017-12-01

    Despite the fact that streamflow occurs mainly due to depletion of storage, our knowledge on how a drainage basin stores and releases water is very limited because of measurement limitations. As a result storage has largely remained an elusive entity in hydrological analysis and modelling. A window of opportunity, however, is given to us by GRACE satellite mission that provides storage anomaly (TWSA) data for the entire globe. Many studies have used TWSA data for storage-discharge analysis, uncovering a range of potential applications of TWSA data. Here we argue that the capability of GRACE satellite mission has not been fully explored as most of the studies in the past have performed storage-discharge analysis using monthly TWSA data for large river basins. With such coarse data we are quite unlikely to fully understand variation of storage and discharge in space and time. In this study, we therefore use daily TWSA data for several mid-sized catchments and perform storage-discharge analysis. Daily storage-discharge relationship is highly dynamic, which generates large amount of scatter in storage-discharge plots. Yet a careful analysis of those scatter plots reveals interesting information on storage-discharge relationships of basins, particularly by looking at the relationships during individual recession events. It is observed that storage-discharge relationship is exponential in nature, contrary to the general assumption that the relationship is linear. We find that there is a strong relationship between power-law recession coefficient and initial storage (TWSA at the beginning of recession event). Furthermore, appreciable relationships are observed between recession coefficient and past TWSA values implying that storage takes time to deplete completely. Overall, insights drawn from this study expands our knowledge on how discharge is dynamically linked to storage.

  16. An analysis of five negative sprite-parent discharges and their associated thunderstorm charge structures

    NASA Astrophysics Data System (ADS)

    Boggs, Levi D.; Liu, Ningyu; Splitt, Michael; Lazarus, Steven; Glenn, Chad; Rassoul, Hamid; Cummer, Steven A.

    2016-01-01

    In this study we analyze the discharge morphologies of five confirmed negative sprite-parent discharges and the associated charge structures of the thunderstorms that produced them. The negative sprite-parent lightning took place in two thunderstorms that were associated with a tropical disturbance in east central and south Florida. The first thunderstorm, which moved onshore in east central Florida, produced four of the five negative sprite-parent discharges within a period of 17 min, as it made landfall from the Atlantic Ocean. These negative sprite-parents were composed of bolt-from-the-blue (BFB), hybrid intracloud-negative cloud-to-ground (IC-NCG), and multicell IC-NCGs discharges. The second thunderstorm, which occurred inland over south Florida, produced a negative sprite-parent that was a probable hybrid IC-NCG discharge and two negative gigantic jets (GJs). Weakened upper positive charge with very large midlevel negative charge was inferred for both convective cells that initiated the negative-sprite-parent discharges. Our study suggests tall, intense convective systems with high wind shear at the middle to upper regions of the cloud accompanied by low cloud-to-ground (CG) flash rates promote these charge structures. The excess amount of midlevel negative charge results in these CG discharges transferring much more charge to ground than typical negative CG discharges. We find that BFB discharges prefer an asymmetrical charge structure that brings the negative leader exiting the upper positive charge region closer to the lateral positive screening charge layer. This may be the main factor in determining whether a negative leader exiting the upper positive region of the thundercloud forms a BFB or GJ.

  17. Facile Synthesis of Bowl-Like LiFePO4/C Composite with High Rate-Performance

    NASA Astrophysics Data System (ADS)

    Jing, Peng; Yao, Lei; Xiang, Mingwu; Wang, Yan; Wu, Jinhua; Wang, Boya; Zhang, Yun; Wu, Hao; Liu, Heng

    2018-07-01

    Olivine-structured LiFePO4/C composites with high rate-performance were synthesized via an industrial spray-drying technique using a low cost Fe3O4 as iron source. The as-obtained LiFePO4/C exhibits a unique bowl-like morphology with a particle size of 2-5 μm in diameter. A continuous uniform carbon coating layer on the surface of LiFePO4/C cathodes promotes fast electron transport, whilst it guarantees the favorable electrochemical reaction. Especially the formation of porous structure leads to an average pore volume of 0.127 cm3 g-1 and a high specific surface area of 34.46 m2 g-1, which is conducive to facilitating the penetration of electrolyte and providing the more contact area of electrolyte with LiFePO4/C. As a result, the as-prepared LiFePO4/C cathode material delivers an outstanding discharge capacity of 102.1 mAh g-1, 94.2% of the initial capacity (108.3 mAh g-1), after 1000 cycles at 10 C. Even at an ultrahigh current rate of 50 C, it still shows an initial discharge capacity of 58 mAh g-1.

  18. Facile Synthesis of Bowl-Like LiFePO4/C Composite with High Rate-Performance

    NASA Astrophysics Data System (ADS)

    Jing, Peng; Yao, Lei; Xiang, Mingwu; Wang, Yan; Wu, Jinhua; Wang, Boya; Zhang, Yun; Wu, Hao; Liu, Heng

    2018-03-01

    Olivine-structured LiFePO4/C composites with high rate-performance were synthesized via an industrial spray-drying technique using a low cost Fe3O4 as iron source. The as-obtained LiFePO4/C exhibits a unique bowl-like morphology with a particle size of 2-5 μm in diameter. A continuous uniform carbon coating layer on the surface of LiFePO4/C cathodes promotes fast electron transport, whilst it guarantees the favorable electrochemical reaction. Especially the formation of porous structure leads to an average pore volume of 0.127 cm3 g-1 and a high specific surface area of 34.46 m2 g-1, which is conducive to facilitating the penetration of electrolyte and providing the more contact area of electrolyte with LiFePO4/C. As a result, the as-prepared LiFePO4/C cathode material delivers an outstanding discharge capacity of 102.1 mAh g-1, 94.2% of the initial capacity (108.3 mAh g-1), after 1000 cycles at 10 C. Even at an ultrahigh current rate of 50 C, it still shows an initial discharge capacity of 58 mAh g-1.

  19. Sodium modified molybdenum sulfide via molten salt electrolysis as an anode material for high performance sodium-ion batteries.

    PubMed

    Wang, Shuai; Tu, Jiguo; Yuan, Yan; Ma, Rui; Jiao, Shuqiang

    2016-01-28

    The paper reports a facile and cost effective method for fabricating sodium molybdenum sulfide nanoparticles through using MoS2 sheets as the precursor by sodium-modification. The electrochemical performances of sodium molybdenum sulfide nanoparticles are studied as anode materials for sodium-ion batteries. The galvanostatic charge-discharge measurements have been performed in a voltage range of 0.01-2.6 V vs. Na(+)/Na under different current densities, using the as-prepared sodium molybdenum sulfide nanoparticles as a working electrode. Typically, the initial discharge and charge capacities of sodium molybdenum sulfide nanoparticles are 475 and 380 mA h g(-1), respectively, at a current density of 20 mA g(-1). The sodium molybdenum sulfide nanoparticles exhibit high capacity with a reversible discharge capacity of about 190 mA h g(-1) after 100 cycles. It should be emphasized that the discharge reaction consists of two steps which correspond to voltage plateaus of 0.93 V and 0.85 V vs. Na(+)/Na in the first discharge curve of the Na/MoS2 battery, respectively. But there is only one apparent voltage plateau in the Na/Na-Mo-S battery, and it reduces to below 0.5 V vs. Na(+)/Na, which can enhance the power density. All of the findings demonstrate that sodium molybdenum sulfide nanoparticles have steady cycling performance and environmental and cost friendliness as next generation secondary batteries.

  20. Impact of case volume on outcome and performance of targeted temperature management in out-of-hospital cardiac arrest survivors.

    PubMed

    Lee, Seung Joon; Jeung, Kyung Woon; Lee, Byung Kook; Min, Yong Il; Park, Kyu Nam; Suh, Gil Joon; Kim, Kyung Su; Kang, Gu Hyun

    2015-01-01

    This study aimed to determine the effect of case volume on targeted temperature management (TTM) performance, incidence of adverse events, and neurologic outcome in comatose out-of-hospital cardiac arrest (OHCA) survivors treated with TTM. We used a Web-based, multicenter registry (Korean Hypothermia Network registry), to which 24 hospitals throughout the Republic of Korea participated to study adult (≥18 years) comatose out-of-hospital cardiac arrest patients treated with TTM between 2007 and 2012. The primary outcome was neurologic outcome at hospital discharge. The secondary outcomes were inhospital mortality, TTM performance, and adverse events. We extracted propensity-matched cohorts to control for bias. Multivariate logistic regression analysis was performed to assess independent risk factors for neurologic outcome. A total of 901 patients were included in this study; 544 (60.4%) survived to hospital discharge, and 248 (27.5%) were discharged with good neurologic outcome. The high-volume hospitals initiated TTM significantly earlier and had lower rates of hyperglycemia, bleeding, hypotension, and rebound hyperthermia. However, neurologic outcome and inhospital mortality were comparable between high-volume (27.7% and 44.6%, respectively) and low-volume hospitals (21.1% and 40.5%) in the propensity-matched cohorts. The adjusted odds ratio for the high-volume hospitals compared with low-volume hospitals was 1.506 (95% confidence interval, 0.875-2.592) for poor neurologic outcome. Higher TTM case volume was significantly associated with early initiation of TTM and lower incidence of adverse events. However, case volume had no association with neurologic outcome and inhospital mortality. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Microstructure investigation of 13Cr-2Mo ODS steel components obtained by high voltage electric discharge compaction technique

    DOE PAGES

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; ...

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10–15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining themore » initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. As a result, the choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.« less

  2. Microstructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique.

    PubMed

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; Chernov, Ivan; Staltsov, Maxim; Khasanov, Oleg; Olevsky, Eugene

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10-15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. The choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

  3. Constructing hierarchical submicrotubes from interconnected TiO2 nanocrystals for high reversible capacity and long-life lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Xin, Ling; Liu, Yong; Li, Baojun; Zhou, Xiang; Shen, Hui; Zhao, Wenxia; Liang, Chaolun

    2014-03-01

    Here, we report a facile hydrothermal approach for synthesizing anatase TiO2 hierarchical mesoporous submicrotubes (ATHMSs) with the aid of long-chain polymer as soft template. The TiO2 nanocrystals, with sizes of 6-8 nm, are well interconnected with each other to build tubular architectures with diameters of 0.3-1.5 μm and lengths of 10-25 μm. Such highly porous structures give rise to very large specific surface area of 201.9 m2 g-1 and 136.8 m2 g-1 for the as-prepared and annealed samples, respectively. By using structurally stable ATHMSs as anode materials for lithium-ion batteries, they exhibited high reversible capacity, long cycling life and excellent cycling stability. Even after 1000 cycles, such ATHMS electrodes retained a reversible discharge capacity as high as 150 mAh g-1 at the current density of 1700 mA g-1, maintaining 92% of the initial discharge capacity (163 mAh g-1).

  4. Neutral-depletion-induced axially asymmetric density in a helicon source and imparted thrust

    NASA Astrophysics Data System (ADS)

    Takahashi, Kazunori; Takao, Yoshinori; Ando, Akira

    2016-02-01

    The high plasma density downstream of the source is observed to be sustained only for a few hundreds of microsecond at the initial phase of the discharge, when pulsing the radiofrequency power of a helicon plasma thruster. Measured relative density of argon neutrals inside the source implies that the neutrals are significantly depleted there. A position giving a maximum plasma density temporally moves to the upstream side of the source due to the neutral depletion and then the exhausted plasma density significantly decreases. The direct thrust measurement demonstrates that the higher thrust-to-power ratio is obtained by using only the initial phase of the high density plasma, compared with the steady-state operation.

  5. High capacity lithium ion batteries composed of cobalt oxide nanoparticle anodes and Raman spectroscopic analysis of nanoparticle strain dynamics in batteries

    NASA Astrophysics Data System (ADS)

    Islam, Mohammad A.; Zuba, Mateusz; DeBiase, Vincent; Noviasky, Nicholas; Hawley, Christopher J.

    2018-02-01

    Cobalt nanoparticle thin films were electrophoretically deposited on copper current collectors and were annealed into thin films of hollow Co3O4 nanoparticles. These thin films were directly used as the anodes of lithium ion batteries (LIBs) without the addition of conducting carbons and bonding agents. LIBs thus fabricated show high gravimetric capacities and long cycle lives. For ≈1.0 μm thick Co3O4 nanoparticle films the gravimetric capacities of the batteries were more than 800 mAh g-1 at a current rate of C/15, which is about 90% of the theoretical maximum. Additionally, the batteries were able to undergo 200 charge/discharge cycles at a relatively fast rate of C/5 and maintain 50% of the initial capacity. In order to understand the electrochemistry of lithiation in the context of nanoparticles, Raman spectra were collected at different stages of the electrode cycles to determine the chemical and structural changes in the nanomaterials. Our results indicate that initially the electrode nanoparticles were under significant strain and as the battery underwent many cycles of charging/discharging the nanoparticles experienced progressive strain relaxation.

  6. The Spatial Expansion of a Discharge in the Generation and the Channel Structure (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlumbohm, H.

    1962-02-01

    The spatial expansion of a discharge was investigated under homogeneous field conditions, using an anode with a small central area separated from the remainder and wide band double beam oscillographic techniques. The discharge currents were initiated by electrons released along traces of single alpha particles in the gas between the electrodes. The k particles enter the gap volume through a small hole in the middle of the separated center of the anode. The measurements have shown that a secondary photon emission from the cathode causes a spreading over the total gap volume within the first few electron generations (N 2,more » air, and CO 2 at lower pressures). If a streamer mechanism occurs (O 2 and CO 2 at higher pressures), the discharge remains localized to the trace of the alpha particle, in which the avalanches yielded by the primary electrons have produced a high density of positive ions. New details of steamer mechanism are revealed by analyzing the rapid increase of the current during streamer formation.« less

  7. Characteristics of long-gap AC streamer discharges under low pressure conditions

    NASA Astrophysics Data System (ADS)

    Yang, Yaqi; Li, Weiguo; Xia, Yu; Yuan, Chuangye

    2017-10-01

    The generation and propagation of a streamer is a significant physical process of air gap discharge. Research on the mechanism of streamers under low-pressure conditions is helpful for understanding the process of long-gap discharge in a high-altitude area. This paper describes laboratory investigations of streamer discharge under alternating current (AC) voltage in a low pressure test platform for a 60 cm rod-plane gap at 30 kPa, and analyzes the characteristics of streamer generation and propagation. The results show that the partial streamer and breakdown streamer all occur in the positive half-cycle of AC voltage near the peak voltage at 30 kPa. The partial streamer could cause the distortion of current and voltage waveform, and it appears as the branching characteristic at the initial stage. With the extension of the streamer, the branching and tortuosity phenomena become gradually obvious, but the branching is suppressed when the streamer crosses the gap. The low-pressure condition has little influence on the tortuosity length and the tortuosity number of the streamer, but affect the diameter of streamer obviously.

  8. Smoking Behavior Change During Compulsory Military Service in Israel, 1987-2011.

    PubMed

    Zarka, Salman; Levine, Hagai; Rozhavski, Vladislav; Sela, Tamar; Bar-Ze'ev, Yael; Molina-Hazan, Vered; Rosen, Laura J

    2017-11-01

    Smoking in military settings is of major concern. We aimed to assess the association between personal, family, and military factors and smoking behavior change during compulsory military service in Israel. Participants were soldiers recruited between 1987 and 2008 who were interviewed at recruitment and reinterviewed at discharge (1987-2011) (total: 29 189; males:15 136; females:14 053). The primary outcome variables were smoking initiation during service among nonsmokers at recruitment, and cessation during service among smokers at recruitment. We examined potential predictors of change, and trends by calendar year. Smoking prevalence increased by 39.4% during military service (recruitment: 26.2%, discharge: 36.5%). 18.4% of nonsmoking recruits initiated smoking, and 12.4% of smoking recruits quit smoking between recruitment and discharge. There was no observed trend in initiation between 1987 and 2011. The strongest predictor of smoking initiation among nonsmokers at recruitment was smoking history (former vs. never-smoker, odds ratio (OR) [95% confidence interval [CI

  9. VRLA Ultrabattery for high-rate partial-state-of-charge operation

    NASA Astrophysics Data System (ADS)

    Lam, L. T.; Louey, R.; Haigh, N. P.; Lim, O. V.; Vella, D. G.; Phyland, C. G.; Vu, L. H.; Furukawa, J.; Takada, T.; Monma, D.; Kano, T.

    The objective of this study is to produce and test the hybrid valve-regulated Ultrabattery designed specifically for hybrid-electric vehicle duty, i.e., high-rate partial-state-of-charge operation. The Ultrabattery developed by CSIRO Energy Technology is a hybrid energy-storage device, which combines an asymmetric supercapacitor, and a lead-acid battery in one unit cells, taking the best from both technologies without the need for extra, expensive electronic controls. The capacitor will enhance the power and lifespan of the lead-acid battery as it acts as a buffer during high-rate discharging and charging. Consequently, this hybrid technology is able to provide and absorb charge rapidly during vehicle acceleration and braking. The work programme of this study is divided into two main parts, namely, field trial of prototype Ultrabatteries in a Honda Insight HEV and laboratory tests of prototype batteries. In this paper, the performance of prototype Ultrabatteries under different laboratory tests is reported. The evaluation of Ultrabatteries in terms of initial performance and cycling performance has been conducted at both CSIRO and Furukawa laboratories. The initial performance of prototype Ultrabatteries, such as capacity, power, cold cranking and self-discharge has been evaluated based upon the US FreedomCAR Battery Test Manual (DOE/ID-11069, October 2003). Results show that the Ultrabatteries meet, or exceed, respective targets of power, available energy, cold cranking and self-discharge set for both minimum and maximum power-assist HEVs. The cycling performance of prototype Ultrabatteries has been evaluated using: (i) simplified discharge and charge profile to simulate the driving conditions of micro-HEV; (ii) 42-V profile to simulate the driving conditions of mild-HEV and (iii) EUCAR and RHOLAB profiles to simulate the driving conditions of medium-HEV. For comparison purposes, nickel-metal-hydride (Ni-MH) cells, which are presently used in the Honda Insight HEV, have also been subjected to some of the above profiles (i.e., simplified discharge and charge profile and EUCAR profile). Although the Ultrabattery and a Ni-MH cell under EUCAR test profile are still on cycling, the outcomes to date show that the performance of these batteries and cells has been at least four times longer than that of the state-of-the art lead-acid cells or batteries. Excitingly, the performance of Ultrabatteries is proven to be comparable with that of the Ni-MH cells.

  10. Prediction of initiation and cessation of breastfeeding from late pregnancy to 16 weeks: the Feeding Your Baby (FYB) cohort study

    PubMed Central

    Donnan, Peter T; Dalzell, Janet; Symon, Andrew; Rauchhaus, Petra; Monteith-Hodge, Ewa; Kellett, Gillian; Wyatt, Jeremy C; Whitford, Heather M

    2013-01-01

    Objective To derive prediction models for both initiation and cessation of breastfeeding using demographic, psychological and obstetric variables. Design A prospective cohort study. Setting Women delivering at Ninewells Hospital, Dundee, UK. Data sources Demographic data and psychological measures were obtained during pregnancy by questionnaire. Birth details, feeding method at birth and at hospital discharge were obtained from the Ninewells hospital database, Dundee, UK. Breastfeeding women were followed up by text messages every 2 weeks until 16 weeks or until breastfeeding was discontinued to ascertain feeding method and feeding intentions. Participants Pregnant women over 30 weeks gestation aged 16 years and above, living in Dundee, booked to deliver at Ninewells Hospital, Dundee, and able to speak English. Main outcome measure Initiation and cessation of breastfeeding. Results From the total cohort of women at delivery (n=344) 68% (95% CI 63% to 73%) of women had started breastfeeding at discharge. Significant predictors of initiating breastfeeding were older age, parity, greater intention to breastfeed from a Theory of Planned Behaviour (TPB)-based questionnaire, higher Iowa Infant Feeding Assessment Scale (IIFAS) score as well as living with a husband or partner. For the final model, the AUROC was 0.967. For those who initiated breastfeeding (n=233), the strongest predictors of stopping were low intention to breastfeed from TPB, low IIFAS score and non-managerial/professional occupations. Conclusions The findings from this study will be used to inform the protocol for an intervention study to encourage and support prolonged breastfeeding as intentions appear to be a key intervention focus for initiation. The predictive models could be used to identify women at high risk of not initiating and also women at high risk of stopping for interventions to improve the longevity of breastfeeding. PMID:23906958

  11. Ultrafine sulfur nanoparticles in conducting polymer shell as cathode materials for high performance lithium/sulfur batteries.

    PubMed

    Chen, Hongwei; Dong, Weiling; Ge, Jun; Wang, Changhong; Wu, Xiaodong; Lu, Wei; Chen, Liwei

    2013-01-01

    We report the synthesis of ultrafine S nanoparticles with diameter 10 ~ 20 nm via a membrane-assisted precipitation technique. The S nanoparticles were then coated with conducting poly (3,4-ethylenedioxythiophene) (PEDOT) to form S/PEDOT core/shell nanoparticles. The ultrasmall size of S nanoparticles facilitates the electrical conduction and improves sulfur utilization. The encapsulation of conducting PEDOT shell restricts the polysulfides diffusion, alleviates self-discharging and the shuttle effect, and thus enhances the cycling stability. The resulting S/PEDOT core/shell nanoparticles show initial discharge capacity of 1117 mAh g(-1) and a stable capacity of 930 mAh g(-1) after 50 cycles.

  12. Annular arc accelerator shock tube

    NASA Technical Reports Server (NTRS)

    Leibowitz, L. P. (Inventor)

    1976-01-01

    An annular arc accelerator shock tube employs a cold gas driver to flow a stream of gas from an expansion section through a high voltage electrode section to a test section, thus driving a shock wave in front of it. A glow discharge detects the shock wave and actuates a trigger generator which in turn fires spark-gap switches to discharge a bank of capacitors across a centered cathode and an annular anode in tandem electrode sections. The initial shock wave passes through the anode section from the cathode section thereby depositing energy into the flow gas without the necessity of any diaphragm opening in the gas flow from the expansion section through the electrode sections.

  13. Ultrafine Sulfur Nanoparticles in Conducting Polymer Shell as Cathode Materials for High Performance Lithium/Sulfur Batteries

    PubMed Central

    Chen, Hongwei; Dong, Weiling; Ge, Jun; Wang, Changhong; Wu, Xiaodong; Lu, Wei; Chen, Liwei

    2013-01-01

    We report the synthesis of ultrafine S nanoparticles with diameter 10 ~ 20 nm via a membrane-assisted precipitation technique. The S nanoparticles were then coated with conducting poly (3,4-ethylenedioxythiophene) (PEDOT) to form S/PEDOT core/shell nanoparticles. The ultrasmall size of S nanoparticles facilitates the electrical conduction and improves sulfur utilization. The encapsulation of conducting PEDOT shell restricts the polysulfides diffusion, alleviates self-discharging and the shuttle effect, and thus enhances the cycling stability. The resulting S/PEDOT core/shell nanoparticles show initial discharge capacity of 1117 mAh g−1 and a stable capacity of 930 mAh g−1 after 50 cycles. PMID:23714786

  14. Ultrafine Sulfur Nanoparticles in Conducting Polymer Shell as Cathode Materials for High Performance Lithium/Sulfur Batteries

    NASA Astrophysics Data System (ADS)

    Chen, Hongwei; Dong, Weiling; Ge, Jun; Wang, Changhong; Wu, Xiaodong; Lu, Wei; Chen, Liwei

    2013-05-01

    We report the synthesis of ultrafine S nanoparticles with diameter 10 ~ 20 nm via a membrane-assisted precipitation technique. The S nanoparticles were then coated with conducting poly (3,4-ethylenedioxythiophene) (PEDOT) to form S/PEDOT core/shell nanoparticles. The ultrasmall size of S nanoparticles facilitates the electrical conduction and improves sulfur utilization. The encapsulation of conducting PEDOT shell restricts the polysulfides diffusion, alleviates self-discharging and the shuttle effect, and thus enhances the cycling stability. The resulting S/PEDOT core/shell nanoparticles show initial discharge capacity of 1117 mAh g-1 and a stable capacity of 930 mAh g-1 after 50 cycles.

  15. Enhanced electrochemical performance of sulfur/polyacrylonitrile composite by carbon coating for lithium/sulfur batteries

    NASA Astrophysics Data System (ADS)

    Peng, Huifen; Wang, Xiaoran; Zhao, Yan; Tan, Taizhe; Mentbayeva, Almagul; Bakenov, Zhumabay; Zhang, Yongguang

    2017-10-01

    A carbon-coated sulfur/polyacrylonitrile (C@S/PAN) core-shell structured composite is successfully prepared via a novel solution processing method. The sulfur/polyacrylonitrile (S/PAN) core particle has a diameter of 100 nm, whereas the carbon shell is about 2 nm thick. The as-prepared C@S/PAN composite shows outstanding electrochemical performance in lithium/sulfur (Li/S) batteries delivering a high initial discharge capacity of 1416 mAh g-1. Furthermore, it exhibits 89% retention of the initial reversible capacity over 200 cycles at a constant current rate of 0.1 C. The improved performance contributed by the unique composition and the core-shell structure, wherein carbon matrix can also withstand the volume change of sulfur during the process of charging and discharging as well as provide channels for electron transport. In addition, polyacrylonitrile (PAN) matrix suppresses the shuttle effect by the covalent bonding between sulfur (S) and carbon (C) in the PAN matrix. [Figure not available: see fulltext.

  16. Progress in the Development of Lightweight Nickel Electrode for Nickel-Hydrogen Cell

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1999-01-01

    Development of a high specific energy battery is one of the objectives of the lightweight nickel-hydrogen (Ni-H2) program at the NASA Glenn Research Center. The approach has been to improve the nickel electrode by continuing combined in-house and contract efforts to develop a lighter weight electrode for the nickel-hydrogen cell. Small fiber diameter nickel plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products and have an advantage of increased surface area available for the deposition of active material. Initial tests include activation and capacity measurements at five different discharge levels, C/2, 1.0 C, 1.37 C, 2.0 C, and 2.74 C. The electrodes are life cycle tested using a half-cell configuration at 40 and 80% depths-of-discharge (DOD) in a low-Earth-orbit regime. The electrodes that pass the initial tests are life cycle-tested in a boiler plate nickel-hydrogen cell before flight weight design are built and tested.

  17. Series-counterpulse repetitive-pulse inductive storage circuit

    DOEpatents

    Honig, Emanuel M.

    1986-01-01

    A high-power series-counterpulse repetitive-pulse inductive energy storage and transfer circuit includes an opening switch, a main energy storage coil, and a counterpulse capacitor. The load pulse is initiated simultaneously with the initiation of the counterpulse which is used to turn the opening switch off. There is no delay from command to output pulse. During the load pulse, the counterpulse capacitor is first discharged and then recharged in the opposite polarity with sufficient energy to accomplish the load counterpulse which terminates the load pulse and turns the load switch off. When the main opening switch is triggered closed again to terminate the load pulse, the counterpulse capacitor discharges in the reverse direction through the load switch and through the load, causing a rapid, sharp cutoff of the load pulse as well as recovering any energy remaining in the load inductance. The counterpulse capacitor is recharged to its original condition by the main energy storage coil after the load pulse is over, not before it begins.

  18. Biological monitoring of Upper Three Runs Creek, Savannah River Plant, Aiken County, South Carolina. Final report on macroinvertebrate stream assessments for F/H area ETF effluent discharge, July 1987--February 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Specht, W.L.

    1991-10-01

    In anticipation of the fall 1988 start up of effluent discharges into Upper Three Creek by the F/H Area Effluent Treatment Facility of the Savannah River Site, Aiken, SC, a two and one half year biological study was initiated in June 1987. Upper Three Runs Creek is an intensively studied fourth order stream known for its high species richness. Designed to assess the potential impact of F?H area effluent on the creek, the study includes qualitative and quantitative macroinvertebrate stream surveys at five sites, chronic toxicity testing of the effluent, water chemistry and bioaccumulation analysis. This final report presents themore » results of both pre-operational and post-operational qualitative and quantitative (artificial substrate) macroinvertebrate studies. Six quantitative and three qualitative studies were conducted prior to the initial release of the F/H ETF effluent and five quantitative and two qualitative studies were conducted post-operationally.« less

  19. Multiple recurrent ischaemic strokes in a patient with cancer: is there a role for the initiation of anticoagulation therapy for secondary stroke prevention?

    PubMed Central

    Suero-Abreu, Giselle Alexandra; Cheng, Jia Zhen; Then, Ryna Karina

    2017-01-01

    A 52-year-old woman with a medical history of cervical and thyroid cancer, hypertension, dyslipidaemia, uncontrolled diabetes and heavy smoking was diagnosed with a new metastatic cholangiocarcinoma. While undergoing palliative chemotherapy, she developed dysarthria and left-sided weakness. Imaging studies showed multiple bilateral ischaemic strokes. On hospital days 2 and 5, she developed worsening neurological symptoms and imaging studies revealed new areas of ischaemia on respective days. Subsequent workup did not revealed a clear aetiology for the multiple ischaemic events and hypercoagulability studies were only significant for a mildly elevated serum D-dimer level. Although guidelines are unclear, full-dose anticoagulation with low molecular weight heparin was initiated given her high risk of stroke recurrence. She was discharged to acute rehabilitation but, within a month, she experienced complications of her malignant disease progression and a new pulmonary thromboembolism. The patient died soon after being discharged home with hospice care. PMID:28578306

  20. Medication reconciliation in acute care: ensuring an accurate drug regimen on admission and discharge.

    PubMed

    Rodehaver, Claire; Fearing, Deb

    2005-07-01

    Several factors contribute to the potential for patient confusion regarding his or her medication regimen, including multiple names for a single drug and formulary variations when the patient receives medications from more than one pharmacy. A 68-year-old woman was discharged from the hospital on a HMG-CoA reductase inhibitor (statin) and resumed her home statin. Eleven days later she returned to the hospital with a diagnosis of severe rhabdomyolysis due to statin overdose. IMPLEMENTING SOLUTIONS: Miami Valley Hospital, Dayton, Ohio, implemented a reconciliation process and order form at admission and discharge to reduce the likelihood that this miscommunication would recur. Initial efforts were trialed on a 44-bed orthopedic unit, with spread of the initiative to the cardiac units and finally to the remaining 22 nursing units. The team successfully implemented initiation of the order sheet, yet audits indicated the need for improvement in reconciling the medications within 24 hours of admission and in reconciling the home medications at the point of discharge. Successful implementation of the order sheet to drive reconciliation takes communication, perseverance, and a multidisciplinary team approach.

  1. Tuning Electrochemical Properties of Li-Rich Layered Oxide Cathodes by Adjusting Co/Ni Ratios and Mechanism Investigation Using in situ X-ray Diffraction and Online Continuous Flow Differential Electrochemical Mass Spectrometry.

    PubMed

    Shen, ShouYu; Hong, YuHao; Zhu, FuChun; Cao, ZhenMing; Li, YuYang; Ke, FuSheng; Fan, JingJing; Zhou, LiLi; Wu, LiNa; Dai, Peng; Cai, MingZhi; Huang, Ling; Zhou, ZhiYou; Li, JunTao; Wu, QiHui; Sun, ShiGang

    2018-04-18

    Owing to high specific capacity of ∼250 mA h g -1 , lithium-rich layered oxide cathode materials (Li 1+ x Ni y Co z Mn (3- x-2 y-3 z)/4 O 2 ) have been considered as one of the most promising candidates for the next-generation cathode materials of lithium ion batteries. However, the commercialization of this kind of cathode materials seriously restricted by voltage decay upon cycling though Li-rich materials with high cobalt content have been widely studied and show good capacity. This research successfully suppresses voltage decay upon cycling while maintaining high specific capacity with low Co/Ni ratio in Li-rich cathode materials. Online continuous flow differential electrochemical mass spectrometry (OEMS) and in situ X-ray diffraction (XRD) techniques have been applied to investigate the structure transformation of Li-rich layered oxide materials during charge-discharge process. The results of OEMS revealed that low Co/Ni ratio lithium-rich layered oxide cathode materials released no lattice oxygen at the first charge process, which will lead to the suppression of the voltage decay upon cycling. The in situ XRD results displayed the structure transition of lithium-rich layered oxide cathode materials during the charge-discharge process. The Li 1.13 Ni 0.275 Mn 0.580 O 2 cathode material exhibited a high initial medium discharge voltage of 3.710 and a 3.586 V medium discharge voltage with the lower voltage decay of 0.124 V after 100 cycles.

  2. Role of electric discharges in the generation of atmospheric vortices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinkevich, O. A., E-mail: oleg.sinkevich@itf.mpei.ac.ru; Maslov, S. A., E-mail: sergm90@mail.ru; Gusein-zade, N. G., E-mail: ngus@mail.ru

    The existing thermohydrodynamic and hydroelectromagnetic models of tornado are considered. The potentialities of the humid atmosphere as a heat engine generating air vortices are analyzed in detail. The ability of long-term atmospheric electric discharges to form a tornado funnel and create an initial twist of up to 10{sup –3}–10{sup –2} s{sup –1} in it are estimated. The possible effect of a lightning discharge on the initiation and evolution of the tornado is discussed. It is shown that the electric current flowing along the lightning channel can lead to helical instability and generation of a weak primary vortex. The channel formedmore » in the atmosphere by a lightning discharge and the vortex motion of the parent thundercloud can enhance the primary vortex and promote its transformation into a tornado. Possible mechanisms of enhancement of the primary vortex created by a lightning discharge and the possibility of its transformation into a tornado in the postdischarge stage are discussed.« less

  3. Wire-chamber radiation detector with discharge control

    DOEpatents

    Perez-Mendez, V.; Mulera, T.A.

    1982-03-29

    A wire chamber; radiation detector has spaced apart parallel electrodes and grids defining an ignition region in which charged particles or other ionizing radiations initiate brief localized avalanche discharges and defining an adjacent memory region in which sustained glow discharges are initiated by the primary discharges. Conductors of the grids at each side of the memory section extend in orthogonal directions enabling readout of the X-Y coordinates of locations at which charged particles were detected by sequentially transmitting pulses to the conductors of one grid while detecting transmissions of the pulses to the orthogonal conductors of the other grid through glow discharges. One of the grids bounding the memory region is defined by an array of conductive elements each of which is connected to the associated readout conductor through a separate resistance. The wire chamber avoids ambiguities and imprecisions in the readout of coordinates when large numbers of simultaneous or; near simultaneous charged particles have been detected. Down time between detection periods and the generation of radio frequency noise are also reduced.

  4. Fundamental studies on initiation and evolution of multi-channel discharges and their application to next generation pulsed power machines.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarz, Jens; Savage, Mark E.; Lucero, Diego Jose

    Future pulsed power systems may rely on linear transformer driver (LTD) technology. The LTD's will be the building blocks for a driver that can deliver higher current than the Z-Machine. The LTD's would require tens of thousands of low inductance ( %3C 85nH), high voltage (200 kV DC) switches with high reliability and long lifetime ( 10 4 shots). Sandia's Z-Machine employs 36 megavolt class switches that are laser triggered by a single channel discharge. This is feasible for tens of switches but the high inductance and short switch life- time associated with the single channel discharge are undesirable formore » future machines. Thus the fundamental problem is how to lower inductance and losses while increasing switch life- time and reliability. These goals can be achieved by increasing the number of current-carrying channels. The rail gap switch is ideal for this purpose. Although those switches have been extensively studied during the past decades, each effort has only characterized a particular switch. There is no comprehensive understanding of the underlying physics that would allow predictive capability for arbitrary switch geometry. We have studied rail gap switches via an extensive suite of advanced diagnostics in synergy with theoretical physics and advanced modeling capability. Design and topology of multichannel switches as they relate to discharge dynamics are investigated. This involves electrically and optically triggered rail gaps, as well as discrete multi-site switch concepts.« less

  5. ITER Side Correction Coil Quench model and analysis

    NASA Astrophysics Data System (ADS)

    Nicollet, S.; Bessette, D.; Ciazynski, D.; Duchateau, J. L.; Gauthier, F.; Lacroix, B.

    2016-12-01

    Previous thermohydraulic studies performed for the ITER TF, CS and PF magnet systems have brought some important information on the detection and consequences of a quench as a function of the initial conditions (deposited energy, heated length). Even if the temperature margin of the Correction Coils is high, their behavior during a quench should also be studied since a quench is likely to be triggered by potential anomalies in joints, ground fault on the instrumentation wires, etc. A model has been developed with the SuperMagnet Code (Bagnasco et al., 2010) for a Side Correction Coil (SCC2) with four pancakes cooled in parallel, each of them represented by a Thea module (with the proper Cable In Conduit Conductor characteristics). All the other coils of the PF cooling loop are hydraulically connected in parallel (top/bottom correction coils and six Poloidal Field Coils) are modeled by Flower modules with equivalent hydraulics properties. The model and the analysis results are presented for five quench initiation cases with/without fast discharge: two quenches initiated by a heat input to the innermost turn of one pancake (case 1 and case 2) and two other quenches initiated at the innermost turns of four pancakes (case 3 and case 4). In the 5th case, the quench is initiated at the middle turn of one pancake. The impact on the cooling circuit, e.g. the exceedance of the opening pressure of the quench relief valves, is detailed in case of an undetected quench (i.e. no discharge of the magnet). Particular attention is also paid to a possible secondary quench detection system based on measured thermohydraulic signals (pressure, temperature and/or helium mass flow rate). The maximum cable temperature achieved in case of a fast current discharge (primary detection by voltage) is compared to the design hot spot criterion of 150 K, which includes the contribution of helium and jacket.

  6. Factors affecting return to oral intake in inpatient rehabilitation after acquired brain injury.

    PubMed

    Kjaersgaard, Annette; Nielsen, Lars Hedemann; Sjölund, Bengt H

    2015-01-01

    To extend previous observations by investigating if differences exist in time to initiation or to recovery of total oral intake in patients with acquired brain injury assessed by either Facial-Oral Tract Therapy (F.O.T.T.) or Fibreoptic Endoscopic Evaluation of Swallowing (FEES) and to investigate whether other factors influence these outcomes. Randomized controlled trial. One hundred and nineteen patients with dysphagia in inpatient neurorehabilitation were randomized. The main outcome was time to maximum on the Functional Oral Intake Scale. There was no difference in time to initiation or recovery of total oral intake using F.O.T.T. or FEES. Oral intake was initiated for 42% on admission and 92% at discharge; 2.5% of the patients were on total oral intake within 24 hours of admission and 37% at discharge. The likelihood of recovery to total oral intake before discharge was found to depend on age, Functional Independence Measure score, length of stay and number of dysphagia interventions. There was no significant difference in time to initiation and recovery of total oral intake before discharge, whether assessed by F.O.T.T. or FEES, indicating that an instrumental assessment is unnecessary for standard evaluation. Age, functional independence and length of stay had a significant influence.

  7. FACTORS AFFECTING THE DISSIPATION OF WINDSCALE RADIOACTIVE EFFLUENT IN THE IRISH SEA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaw, A.E.; Charlesworth, F.R.

    1952-02-20

    diffusion, and residual currents was orginally assessed by Seligman and Scott in 1948. Further experimental work is described which has enabled a new assessment to be made. This work has included a measurement of the initial dilution of fresh water from the pipe line, and a study of the movement of water as indicated by drift bottles. lt is now envisaged that initial dilution, by a factor of 10, will be followed by eddy diffusion with the coefficients as measured by Seligman, and bulk movement primarily due to the force of the wind. Exceptions will occur when defined calm conditionsmore » exist. The discharged effluent will then tend to float on the surface with an initial dilution factor of only a few hundred and successive tidal releases will pour into the diffusing remains of the previous activity, there being no indications of residual currents. No work has been done to see if this more concentrated effluent can come ashore without further dilution. lt is recommended that, to avoid floating effluent, water should not be discharged during very calm weather. Maximum storage space can be assured by normally pumping effluent to sea at the next high tide after treatment. (auth)« less

  8. 46 CFR 108.437 - Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Pipe sizes and discharge rates for enclosed ventilation... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. (a) The minimum pipe size for the initial...

  9. Sex Disparities in Post-Acute Myocardial Infarction Pharmacologic Treatment Initiation and Adherence: Problem for Young Women.

    PubMed

    Smolina, Kate; Ball, Laura; Humphries, Karin H; Khan, Nadia; Morgan, Steven G

    2015-11-01

    The prevalence of the use of secondary prevention cardiovascular medications is lower among women than men, but it is unclear if this is a result of lower treatment initiation among women or lower treatment adherence. We aimed to map the treatment pathway for survivors of acute myocardial infarction (AMI) by sex and age. This retrospective population-based cohort study used linked administrative data sets in British Columbia (2004-2011), which include health care, prescription drugs, sociodemographic, and mortality information. The study cohort included all individuals admitted to hospital for AMI in 2007-2009 and survived for 1 year after hospital discharge. Patients were evaluated for whether they initiated and then subsequently filled prescriptions angiotensin-converting enzyme inhibitors, β-blockers, and statins. More than two thirds of AMI survivors initiated treatment on all appropriate medications, given their contraindications, within 2 months of discharge. Younger men were significantly more likely than younger women to initiate appropriate treatment (adjusted odds ratio, 1.38; 95% confidence interval, 1.10-1.75). By the end of 1 year after discharge, only one third of all AMI survivors filled all appropriate prescriptions for at least 80% of the year. There was no significant difference in adherence to medication therapy between women and men. The majority of AMI survivors either discontinue treatment or do not refill their prescriptions consistently. Women <55 years are significantly less likely to be on optimal therapy by the end of 1 year after discharge, which is driven by a sex disparity in treatment initiation and not treatment adherence. © 2015 American Heart Association, Inc.

  10. Tailoring Anisotropic Li-Ion Transport Tunnels on Orthogonally Arranged Li-Rich Layered Oxide Nanoplates Toward High-Performance Li-Ion Batteries.

    PubMed

    Xu, Ming; Fei, Linfeng; Zhang, Weibing; Li, Tao; Lu, Wei; Zhang, Nian; Lai, Yanqing; Zhang, Zhian; Fang, Jing; Zhang, Kai; Li, Jie; Huang, Haitao

    2017-03-08

    High-performance Li-rich layered oxide (LRLO) cathode material is appealing for next-generation Li-ion batteries owing to its high specific capacity (>300 mAh g -1 ). Despite intense studies in the past decade, the low initial Coulombic efficiency and unsatisfactory cycling stability of LRLO still remain as great challenges for its practical applications. Here, we report a rational design of the orthogonally arranged {010}-oriented LRLO nanoplates with built-in anisotropic Li + ion transport tunnels. Such a novel structure enables fast Li + ion intercalation and deintercalation kinetics and enhances structural stability of LRLO. Theoretical calculations and experimental characterizations demonstrate the successful synthesis of target cathode material that delivers an initial discharge capacity as high as 303 mAh g -1 with an initial Coulombic efficiency of 93%. After 200 cycles at 1.0 C rate, an excellent capacity retention of 92% can be attained. Our method reported here opens a door to the development of high-performance Ni-Co-Mn-based cathode materials for high-energy density Li-ion batteries.

  11. Composite electronic materials based on poly(3,4-propylenedioxythiophene) and highly charged poly(aryleneethynylene)-wrapped carbon nanotubes for supercapacitors.

    PubMed

    Rosario-Canales, Mariem R; Deria, Pravas; Therien, Michael J; Santiago-Avilés, Jorge J

    2012-01-01

    Supercapacitor charge storage media were fabricated using the semiconducting polymer poly(3,4-propylenedioxythiophene) (PProDOT) and single-walled carbon nanotubes (SWNTs) that were helically wrapped with ionic, conjugated poly[2,6-{1,5-bis(3-propoxysulfonicacidsodiumsalt)}naphthylene]ethynylene (PNES). These PNES-wrapped SWNTs (PNES-SWNTs) enable efficient dispersion of individualized nanotubes in a wide range of organic solvents. PNES-SWNT film-modified Pt electrodes were prepared by drop casting PNES-SWNT suspensions in MeOH; high stability, first-generation PProDOT/PNES/SWNT composites were realized via electropolymerization of the ProDOT parent monomer (3,4-propylenedioxythiophene) in a 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide/propylene carbonate solution at the PNES-SWNT-modified electrode. The electrochemical properties of PProDOT and PProDOT/PNES/SWNT single electrodes and devices were examined using cyclic voltammetric methods. The hybrid composites were found to enhance key supercapacitor figures of merit (charge capacity and capacitance) by approximately a factor of 2 relative to those determined for benchmark Type I devices that exploited a classic PProDOT-based electrode material. The charge/discharge stability of the supercapacitors was probed by repeated rounds of cyclic voltammetric evaluation at a minimum depth of discharge of 73%; these experiments demonstrated that the hybrid PProDOT/PNES/SWNT composites retained ~90% of their initial charge capacity after 21,000 charge/discharge cycles, contrasting analogous data obtained for PProDOT-based devices, which showed only 84% retention of their initial charge capacity. © 2011 American Chemical Society

  12. Optical Properties and Electrochemical Performance of LiFePO4 Thin Films Deposited on Transparent Current Collectors.

    PubMed

    Lee, HyunSeok; Yim, Haena; Kim, Kwang-Bum; Choi, Ji-Won

    2015-11-01

    LiFePO4 thin film cathodes are deposited on various transparent conducting oxide thin films on glass, which are used as cathode current collectors. The XRD patterns show that the thin films have the phase of LiFePO4 with an ordered olivine structure indexed to the orthorhombic Pmna space group. LiFePO4 thin film deposited on various TCO glass substrates exhibits transmittance of about 53%. The initial specific discharge capacities of LiFePO4 thin films are 25.0 μAh/cm2 x μm on FTO, 33.0 μAh/cm2 x μm on ITO, and 13.0 μAh/cm2 x μm on AZO coated glass substrates. Interestingly, the retention capacities of LiFePO4 thin films are 76.0% on FTO, 31.2% on ITO, and 37.7% on AZO coated glass substrates at 20th cycle. The initial specific discharge capacity of the LiFePO4/FTO electrode is slightly lower, but the discharge capacities of the LiFePO4/FTO electrode relatively decrease less than those of the others such as LiFePO4/ITO and LiFePO4/AZO with cycling. The results reported here provide the high transparency of LiFePO4 thin films cathode materials and the good candidate as FTO current collector of the LiFePO4 thin film cathode of transparent thin film rechargeable batteries due to its high transparency and cyclic retention.

  13. Initial Thomson Scattering Survey of Local Helicity Injection and Ohmic Plasmas at the Pegasus Toroidal Experiment

    NASA Astrophysics Data System (ADS)

    Schlossberg, D. J.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Winz, G. R.

    2014-10-01

    A multipoint Thomson scattering diagnostic has recently been installed on the Pegasus ST. The system utilizes a frequency-doubled Nd:YAG laser (λ0 ~ 532 nm), spectrometers with volume phase holographic gratings, and a gated, intensified CCD camera. It provides measurements of Te and ne at 8 spatial locations for each spectrometer once per discharge. A new multiple aperture and beam dump system has been implemented to mitigate interference from stray light. This system has provided initial measurements in the core region of plasmas initiated by local helicity injection (LHI), as well as conventional Ohmic L- and H-mode discharges. Multi-shot averages of low-density (ne ~ 3 ×1018 m-3) , Ip ~ 0 . 1 MA LHI discharges show central Te ~ 75 eV at the end of the helicity injection phase. Ip ~ 0 . 13 MA Ohmic plasmas at moderate densities (ne ~ 2 ×1019 m-3) have core Te ~ 150 eV in L-mode. Generally, these plasmas do not reach transport equilibrium in the short 25 ms pulse length available. After an L-H transition, strong spectral broadening indicates increasing Te, to values above the range of the present spectrometer system with a high-dispersion VPH grating. Near-term system upgrades will focus on deploying a second spectrometer, with a lower-dispersion grating capable of measuring the 0.1-1.0 keV range. The second spectrometer system will also increase the available number of spatial channels, enabling study of H-mode pedestal structure. Work supported by US DOE Grant DE-FG02-96ER54375.

  14. Plasma-panel based detectors

    NASA Astrophysics Data System (ADS)

    Friedman, Peter

    2017-09-01

    The plasma panel sensor (PPS) is a novel micropattern gas detector inspired by plasma display panels (PDPs), the core component of plasma-TVs. A PDP comprises millions of discrete cells per square meter, each of which, when provided with a signal pulse, can initiate and sustain a plasma discharge. Configured as a detector, a pixel or cell is biased to discharge when a free-electron is generated in the gas. The PPS consists of an array of small plasma discharge pixels, and can be configured to have either an ``open-cell'' or ``closed-cell'' structure, operating with high gain in the Geiger region. We describe both configurations and their application to particle physics. The open-cell PPS lends itself to ultra-low-mass, ultrathin structures, whereas the closed-cell microhexcavity PPS is capable of higher performance. For the ultrathin-PPS, we are fabricating 3-inch devices based on two types of extremely thin, inorganic, transparent, substrate materials: one being 8-10 µm thick, and the other 25-27 µm thick. These gas-filled ultrathin devices are designed to operate in a beam-line vacuum environment, yet must be hermetically-sealed and gas-filled in an ambient environment at atmospheric pressure. We have successfully fabricated high resolution, submillimeter pixel electrodes on both types of ultrathin substrates. We will also report on the fabrication, staging and operation of the first microhexcavity detectors (µH-PPS). The first µH-PPS prototype devices have a 16 by 16 matrix of closed packed hexagon pixels, each having a 2 mm width. Initial tests of these detectors, conducted with Ne based gases at atmospheric pressure, indicate that each pixel responds independent of its neighboring cells, producing volt level pulse amplitudes in response to ionizing radiation. Results will include the hit rate response to a radioactive beta source, cosmic ray muons, the background from spontaneous discharge, pixel isolation and uniformity, and efficiency measurements. This work was funded in part by a DOE Office of Nuclear Physics SBIR Phase-II Grant.

  15. Under Voltage Lock-Out Design Rules for Proper Start-Up of Energy Autonomous Systems Powered by Supercapacitors

    NASA Astrophysics Data System (ADS)

    Boitier, V.; Durand Estèbe, P.; Monthéard, R.; Bafleur, M.; Dilhac, J. M.

    2013-12-01

    This paper deals with the issue of the initial start-up of an autonomous and battery-free system powered by an energy harvester associated with a storage subsystem based on supercapacitors initially discharged. A review of different low power Under Voltage Lock-Out (UVLO) solutions used to delay the load start-up and to avoid a useless discharge of supercapacitors is presented and discussed.

  16. Triggered lightning strikes to aircraft and natural intracloud discharges

    NASA Technical Reports Server (NTRS)

    Mazur, Vladislav

    1989-01-01

    The physical model of Mazur (1989) for triggering lightning strikes by aircraft was used to interpret the initiation of intracloud flashes observed by the French UHF-VHF interferometric system. It is shown that both the intracloud discharges and airplane-triggered lightning strikes were initiated by simultaneous bidirectional development of the negative stepped leader and the positive leader-continous current process. However, the negative stepped leader phase in triggered flashes is of shorter duration (tens of milliseconds), than that in intracloud flashes (usually hundreds of milliseconds). This is considered to be due to the fact that, on the aircraft there is a single initiation process, versus the numerous initiation processes that occur inside the cloud.

  17. Synthesis of hierarchical mesoporous lithium nickel cobalt manganese oxide spheres with high rate capability for lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Tong, Wei; Huang, Yudai; Cai, Yanjun; Guo, Yong; Wang, Xingchao; Jia, Dianzeng; Sun, Zhipeng; Pang, Weikong; Guo, Zaiping; Zong, Jun

    2018-01-01

    Hierarchical mesoporous LiNi1/3Co1/3Mn1/3O2 spheres have been synthesized by urea-assisted solvothermal method with adding Triton X-100. The structure and morphology of the as-prepared materials were analyzed by X-ray diffraction and electron microscope. The results show that the as-prepared samples can be indexed as hexagonal layered structure with hierarchical architecture, and the possible formation mechanism is speculated. When evaluated as cathode material, the hierarchical mesoporous LiNi1/3Co1/3Mn1/3O2 spheres show good electrochemical properties with high initial discharge capacity of 129.9 mAh g-1, and remain the discharge capacity of 95.5 mAh g-1 after 160 cycles at 10C. The excellent electrochemical performance of the as-prepared sample can be attributed to its stable hierarchical mesoporous framework in conjunction with large specific surface, low cation mixing and small particle size. They not only provide a large number of reaction sites for surface or interface reaction, but also shorten the diffusion length of Li+ ions. Meanwhile, the mesoporous spheres composed of nanoparticles can contribute to high rate ability and buffer volume changes during charge/discharge process.

  18. On nuclear DD synthesis at the initial stage of nanosecond vacuum discharge with deuterium-loaded Pd anode

    NASA Astrophysics Data System (ADS)

    Kurilenkov, Yu K.; Gus'kov, S. Yu; Karpukhin, V. T.; Oginov, A. V.; Samoylov, I. S.

    2018-01-01

    Earlier, there was demonstrated generation of DD neutrons in an interelectrode medium of a low-energy (˜ 1 J) nanosecond vacuum discharge with a hollow cathode and a deuterium-loaded Pd anode. There was revealed essential role of formation of a virtual cathode and a potential well corresponding thereto in the processes of collisional DD synthesis in the interelectrode space. In this work, we have obtained as a result of an experiment and discussed the neutron yield at the very initial stage of the discharge, when the beam of auto-electrons just starts to irradiate the non-ideal surface of the deuterium-loaded Pd anode.

  19. The Application of Perfluorocarbons as Impregnants for Plastic Film Capacitors

    NASA Technical Reports Server (NTRS)

    Mauldin, G. H.

    1981-01-01

    A liquid impregnated, plastic film (wet) capacitor was developed that is thought to be the most reliable and space efficient capacitor of any type ever produced for high voltage, pulse discharge service. The initial design stores five times the energy of a premium quality dry capacitor of equivalent energy and reliability. The technology, as well as a production capacitor design using this technology are described.

  20. Safe arming system for two-explosive munitions

    DOEpatents

    Jaroska, Miles F.; Niven, William A.; Morrison, Jasper J.

    1978-01-01

    A system for safely and positively detonating high-explosive munitions, including a source of electrical signals, a split-phase square-loop transformer responsive solely to a unique series of signals from the source for charging an energy storage circuit through a voltage doubling circuit, and a spark-gap trigger for initiating discharge of the energy in the storage circuit to actuate a detonator and thereby fire the munitions.

  1. Degradation of α-Naphthol by Plasma in Aqueous Solution

    NASA Astrophysics Data System (ADS)

    Gao, Jin-zhang; Hu, Zhong-ai; Wang, Xiao-yan; Hou, Jing-guo; Lu, Xiao-quan; Kang, Jing-wan

    2001-02-01

    Degradation of α-naphthol induced by plasma in aqueous solution was investigated in different initial concentration with contact glow discharge electrolysis (CGDE). The results showed that the degradation of α-naphthol obeyed the first-rate law. Some of predominant products were analyzed by a high performance liquid chromatography (HPLC). A path of α-naphthol disappearance caused by plasma was proposed according to the detected intermediate products.

  2. High Voltage Testing. Volume 2. Specifications and Test Procedures

    DTIC Science & Technology

    1982-08-01

    the greatest impact on the initial assumption and criteria developed in the published criteria documents include: dielectric withstanding voltage...3382-75 Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques. ASTM-D 3426 - Dielectric... Energy (NEMA Publication No. WC 7-1971). NEMA Publication No. 109 - AIEE-EEI-NEMA Standard Basic Insulation Level. 092-57 - Method of Test for Flash and

  3. Behavior of motor units in human biceps brachii during a submaximal fatiguing contraction.

    PubMed

    Garland, S J; Enoka, R M; Serrano, L P; Robinson, G A

    1994-06-01

    The activity of 50 single motor units was recorded in the biceps brachii muscle of human subjects while they performed submaximal isometric elbow flexion contractions that were sustained to induce fatigue. The purposes of this study were to examine the influence of fatigue on motor unit threshold force and to determine the relationship between the threshold force of recruitment and the initial interimpulse interval on the discharge rates of single motor units during a fatiguing contraction. The discharge rate of most motor units that were active from the beginning of the contraction declined during the fatiguing contraction, whereas the discharge rates of most newly recruited units were either constant or increased slightly. The absolute threshold forces of recruitment and derecruitment decreased, and the variability of interimpulse intervals increased after the fatigue task. The change in motor unit discharge rate during the fatigue task was related to the initial rate, but the direction of the change in discharge rate could not be predicted from the threshold force of recruitment or the variability in the interimpulse intervals. The discharge rate of most motor units declined despite an increase in the excitatory drive to the motoneuron pool during the fatigue task.

  4. Emergency department revisits for patients with kidney stones in California.

    PubMed

    Scales, Charles D; Lin, Li; Saigal, Christopher S; Bennett, Carol J; Ponce, Ninez A; Mangione, Carol M; Litwin, Mark S

    2015-04-01

    Kidney stones affect nearly one in 11 persons in the United States, and among those experiencing symptoms, emergency care is common. In this population, little is known about the incidence of and factors associated with repeat emergency department (ED) visits. The objective was to identify associations between potentially mutable factors and the risk of an ED revisit for patients with kidney stones in a large, all-payer cohort. This was a retrospective cohort study of all patients in California initially treated and released from EDs for kidney stones between February 2008 and November 2009. A multivariable regression model was created to identify associations between patient-level characteristics, area health care resources, processes of care, and the risk of repeat ED visits. The primary outcome was a second ED visit within 30 days of the initial discharge from emergent care. Among 128,564 patients discharged from emergent care, 13,684 (11%) had at least one additional emergent visit for treatment of their kidney stone. In these patients, nearly one in three required hospitalization or an urgent temporizing procedure at the second visit. On multivariable analysis, the risk of an ED revisit was associated with insurance status (e.g., Medicaid vs. private insurance; odds ratio [OR] = 1.52, 95% confidence interval [CI] = 1.43 to 1.61; p < 0.001). Greater access to urologic care was associated with lower odds of an ED revisit (highest quartile OR = 0.88, 95% CI = 0.80 to 0.97; p < 0.01 vs. lowest quartile). In exploratory models, performance of a complete blood count was associated with a decreased odds of revisit (OR = 0.86, 95% CI = 0.75 to 0.97; p = 0.02). Repeat high-acuity care affects one in nine patients discharged from initial emergent evaluations for kidney stones. Access to urologic care and processes of care are associated with lower risk of repeat emergent encounters. Efforts are indicated to identify preventable causes of ED revisits for kidney stone patients and design interventions to reduce the risk of high-cost, high-acuity, repeat care. © 2015 by the Society for Academic Emergency Medicine.

  5. Notes on initial disturbance fields for the transition problem

    NASA Technical Reports Server (NTRS)

    Bushnell, Dennis

    1990-01-01

    Initial disturbance fields are categorized and discussed with respect to modes of disturbance and the variants which occur for each test technique. Attention is focused on four fluctuation modes included under the category of stream turbulence: vorticity fluctuations, entropy disturbances or temperature spottiness, noise, and concentration fluctuations. The mechanisms by which particulate matter can affect transition are discussed, along with electrostatic discharges with frequencies in the range from 200 KHz to 30 MHz which is within the critical disturbance-frequency range for many high-speed flows. Acoustic radiation from own vehicle, roughness, and Brownian motion are also covered.

  6. Apparatus and method for tuned unsteady flow purging of high pulse rate spark gaps

    DOEpatents

    Thayer, III, William J.

    1990-01-01

    A spark gap switch apparatus is disclosed which is capable of operating at a high pulse rate which comprises an insulated housing; a pair of spaced apart electrodes each having one end thereof within a first bore formed in the housing and defining a spark gap therebetween; a pressure wave reflector in the first bore in the housing and spaced from the spark gap and capable of admitting purge flow; and a second enlarged bore contiguous with the first bore and spaced from the opposite side of the spark gap; whereby pressure waves generated during discharge of a spark across the spark gap will reflect off the wave reflector and back from the enlarged bore to the spark gap to clear from the spark gap hot gases residues generated during the discharge and simultaneously restore the gas density and pressure in the spark gap to its initial value.

  7. Nafion coated sulfur-carbon electrode for high performance lithium-sulfur batteries

    NASA Astrophysics Data System (ADS)

    Tang, Qiwei; Shan, Zhongqiang; Wang, Li; Qin, Xue; Zhu, Kunlei; Tian, Jianhua; Liu, Xuesheng

    2014-01-01

    In this paper, a nafion coated electrode is prepared to improve the performance of lithium sulfur batteries. It is demonstrated from a series of measurements that the nafion layer is quite effective in reducing shuttle effect and enhancing the stability and the reversibility of the electrode. When measured under the rate of 0.2 C, the initial discharge capacity of the nafion coated electrode can reach 1084 mAh g-1, with a Columbic efficiency of about 100%. After 100 charge/discharge cycles, this electrode can also deliver a reversible capacity of as high as 879 mAh g-1. Significantly, the charge-transfer resistance of the electrode tends to be reducing after coated with an appropriate thickness of nafion film. The cation conductivity as well as anion inconductivity is considered to be the dominant factor for the superior electrochemical properties.

  8. Degradation of selected organophosphate pesticides in wastewater by dielectric barrier discharge plasma.

    PubMed

    Hu, Yingmei; Bai, Yanhong; Yu, Hu; Zhang, Chunhong; Chen, Jierong

    2013-09-01

    In this paper, degradation of selected organophosphate pesticides (dichlorvos and dimethoate) in wastewater by dielectric barrier discharge plasma (DBD) was studied. DBD parameters, i.e. discharge powers and air-gap distances, differently affect their degradation efficiency. The results show that better degradation efficiency is obtained with a higher discharge power and a shorter air-gap distance. The effect of radical intervention degradation was also investigated by adding radical scavenger (tert-butyl alcohol) to the pesticide solution during the experiments. The result shows that the degradation efficiency is restrained in the presence of radical scavenger. It clearly demonstrates that hydroxyl radicals are most likely the main driver for degradation process. Moreover, the kinetics indicate that the disappearance rate of pesticides follows the first-order rate law when the initial concentration of the solution is low, but shifts to zero-order at a higher initial concentration.

  9. Dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during a subnanosecond breakdown initiated by runaway electrons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tarasenko, V. F., E-mail: vft@loi.hcei.tsc.ru; Beloplotov, D. V.; Lomaev, M. I.

    2015-10-15

    The dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during breakdown of a gap with a nonuniform distribution of the electric field by nanosecond high-voltage pulses was studied experimentally. Measurements of the amplitude and temporal characteristics of a diffuse discharge and its radiation with a subnanosecond time resolution have shown that, at any polarity of the electrode with a small curvature radius, breakdown of the gap occurs via two ionization waves, the first of which is initiated by runaway electrons. For a voltage pulse with an ∼500-ps front, UV radiation from different zones of a diffuse dischargemore » is measured with a subnanosecond time resolution. It is shown that the propagation velocity of the first ionization wave increases after its front has passed one-half of the gap, as well as when the pressure in the discharge chamber is reduced and/or when SF{sub 6} is replaced with air or nitrogen. It is found that, at nitrogen pressures of 0.4 and 0.7 MPa and the positive polarity of the high-voltage electrode with a small curvature radius, the ionization wave forms with a larger (∼30 ps) time delay with respect to applying the voltage pulse to the gap than at the negative polarity. The velocity of the second ionization wave propagating from the plane electrode is measured. In a discharge in nitrogen at a pressure of 0.7 MPa, this velocity is found to be ∼10 cm/ns. It is shown that, as the nitrogen pressure increases to 0.7 MPa, the propagation velocity of the front of the first ionization wave at the positive polarity of the electrode with a small curvature radius becomes lower than that at the negative polarity.« less

  10. Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Chapman, P.

    1982-01-01

    Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

  11. A mathematical approach for evaluating nickel-hydrogen cells

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.

    1986-01-01

    A mathematical equation is presented which gives a quantitative relationship between time-voltage discharge curves, when a cell's ampere-hour capacity is determined at a constant discharge current. In particular the equation quantifies the initial exponential voltage decay; the rate of voltage decay; the overall voltage shift of the curve and the total capacity of the cell at the given discharge current. The results of 12 nickel-hydrogen boiler plate cells cycled to 80 percent depth-of-discharge (DOD) are discussed in association with these equations.

  12. Low current plasmatron fuel converter having enlarged volume discharges

    DOEpatents

    Rabinovich, Alexander; Alexeev, Nikolai; Bromberg, Leslie; Cohn, Daniel R.; Samokhin, Andrei

    2005-04-19

    A novel apparatus and method is disclosed for a plasmatron fuel converter (""plasmatron"") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.

  13. Low current plasmatron fuel converter having enlarged volume discharges

    DOEpatents

    Rabinovich, Alexander [Swampscott, MA; Alexeev, Nikolai [Moscow, RU; Bromberg, Leslie [Sharon, MA; Cohn, Daniel R [Chestnut Hill, MA; Samokhin, Andrei [Moscow, RU

    2009-10-06

    A novel apparatus and method is disclosed for a plasmatron fuel converter ("plasmatron") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.

  14. Lightning and middle atmospheric discharges in the atmosphere

    NASA Astrophysics Data System (ADS)

    Siingh, Devendraa; Singh, R. P.; Kumar, Sarvan; Dharmaraj, T.; Singh, Abhay K.; Singh, Ashok K.; Patil, M. N.; Singh, Shubha

    2015-11-01

    Recent development in lightning discharges including transient luminous events (TLEs) and global electric circuit are discussed. Role of solar activity, convective available potential energy, surface temperature and difference of land-ocean surfaces on convection process are discussed. Different processes of discharge initiation are discussed. Events like sprites and halos are caused by the upward quasi-electrostatic fields associated with intense cloud-to-ground discharges while jets (blue starter, blue jet, gigantic jet) are caused by charge imbalance in thunderstorm during lightning discharges but they are not associated with a particular discharge flash. Elves are generated by the electromagnetic pulse radiated during lightning discharges. The present understanding of global electric circuit is also reviewed. Relation between lightning activity/global electric circuit and climate is discussed.

  15. Observation of Dust Stream Formation Produced by Low Current, High Voltage Cathode Spots

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2004-01-01

    Macro-particle acceleration driven by low current, high voltage cathode spots has been investigated. The phenomenon was observed to occur when nanometer and micrometer-sized particles in the presence of a discharge plasma were exposed to a high voltage pulse. The negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provides the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. The particle impact craters observed at the surface of downstream witness badges were documented using SEM and light microscopy.

  16. Recombination of electrons with water cluster ions in the afterglow of a high-voltage nanosecond discharge

    NASA Astrophysics Data System (ADS)

    Popov, M. A.; Kochetov, I. V.; Starikovskiy, A. Yu; Aleksandrov, N. L.

    2018-07-01

    The results of the experimental and numerical study of high-voltage nanosecond discharge afterglow in H2O:N2 and H2O:O2 mixtures are presented for room temperature and at pressures from 2 to 5 Torr. Time-resolved electron density during the plasma decay was measured with a microwave interferometer for initial electron densities in the range between 1  ×  1012 and 2  ×  1012 cm‑3. Calculations showed that the plasma decay was controlled by recombination of thermalized electrons with H3O+(H2O) n ions for n from 0 to 4. Agreement between calculated and measured electron density histories was obtained only when using the recombination coefficients measured in the pulsed plasma afterglow experiments. The electron densities calculated using the data from the storage ring experiments were consistently greater than the values measured in this work for all conditions. It was concluded that the measurements of recombination coefficients for H3O+(H2O) n ions in the pulsed plasma afterglow were more appropriate for simulating the properties of high-density plasmas with high fractions of H2O, O2 and N2, such as discharge plasmas in water vapor and in humid air instead of the measurements in the storage ring experiments.

  17. O3-type layered transition metal oxide Na(NiCoFeTi) 1/4O 2 as a high rate and long cycle life cathode material for sodium ion batteries

    DOE PAGES

    Yue, Ji -Li; Yang, Xiao -Qing; Zhou, Yong -Ning; ...

    2015-10-09

    High rate capability and long cycle life are challenging goals for the development of room temperature sodium-ion batteries. Here we report a new single phase quaternary O3-type layer-structured transition metal oxide Na(NiCoFeTi) 1/4O 2 synthesized by a simple solid-state reaction as a new cathode material for sodium-ion batteries. It can deliver a reversible capacity of 90.6 mA h g –1 at a rate as high as 20C. At 5C, 75.0% of the initial specific capacity can be retained after 400 cycles with a capacity-decay rate of 0.07% per cycle, demonstrating a superior long-term cyclability at high current density. X-ray diffractionmore » and absorption characterization revealed reversible phase transformations and electronic structural changes during the Na + deintercalation/intercalation process. Ni, Co and Fe ions contribute to charge compensation during charge and discharge. Although Ti ions do not contribute to the charge transfer, they play a very important role in stabilizing the structure during charge and discharge by suppressing the Fe migration. Additionally, Ti substitution can also smooth the charge–discharge plateaus effectively, which provides a potential advantage for the commercialization of this material for room temperature sodium-ion batteries.« less

  18. Slow-moving and far-travelled dense pyroclastic flows during the Peach Spring super-eruption.

    PubMed

    Roche, O; Buesch, D C; Valentine, G A

    2016-03-07

    Explosive volcanic super-eruptions of several hundred cubic kilometres or more generate long run-out pyroclastic density currents the dynamics of which are poorly understood and controversial. Deposits of one such event in the southwestern USA, the 18.8 Ma Peach Spring Tuff, were formed by pyroclastic flows that travelled >170 km from the eruptive centre and entrained blocks up to ∼ 70-90 cm diameter from the substrates along the flow paths. Here we combine these data with new experimental results to show that the flow's base had high-particle concentration and relatively modest speeds of ∼ 5-20 m s(-1), fed by an eruption discharging magma at rates up to ∼ 10(7)-10(8) m(3) s(-1) for a minimum of 2.5-10 h. We conclude that sustained high-eruption discharge and long-lived high-pore pressure in dense granular dispersion can be more important than large initial velocity and turbulent transport with dilute suspension in promoting long pyroclastic flow distance.

  19. Predictors of the discharge dosage of an atypical antipsychotic agent among hospitalized, treatment-naive, first-episode psychosis patients in naturalistic, public-sector settings.

    PubMed

    Compton, Michael T; Kelley, Mary E; Lloyd, Robert Brett; McClam, Tamela; Ramsay, Claire E; Haggard, Patrick J; Augustin, Sara

    2011-02-01

    Little is known about determinants of second-generation antipsychotic dosages during initial hospitalization of first-episode psychosis. This study examined potential predictors of dosage of an atypical antipsychotic agent, risperidone, at hospital discharge after initial evaluation and treatment of first-episode nonaffective psychosis in 3 naturalistic, public-sector treatment settings. The number of psychotropic agents prescribed and discharge antipsychotic dosage were abstracted from the medical record. Demographic and extensive clinical characteristics were assessed through a clinical research study conducted at the 3 sites. One-way analyses of variance, trend tests using specific linear combinations of estimates, and χ² tests assessed for associations between atypical antipsychotic dosage and 5 hypothesized predictors, as well as 12 exploratory variables. Among 155 hospitalized first-episode patients, 121 (78.1%) were discharged on risperidone, and subsequent analyses focused on that subset. The mean risperidone dosage among those 121 patients was 4.26 mg; 31 received 1 to 2 mg, 45 received 3 to 4 mg, 37 received 5 to 6 mg, and 8 received more than 6 mg. Analyses suggested that older age at hospitalization, the number of psychotropic agents prescribed, excited symptoms, and premorbid social functioning may be predictors of the discharge dosage. Although several factors emerged, in general, predictors of discharge dosages of second-generation agents, here exemplified by risperidone, in real-world practice settings remain to be clarified. Given the importance of antipsychotic initiation during first hospitalization, future research should test an even broader array of potential predictors.

  20. Laser-initiated channels for ion transport: breakdown and channel evolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olsen, J.N.; Baker, L.

    1981-05-01

    The electrical breakdown and discharge evolution in CO/sub 2/ laser-heated molecular gases has been studied. With the laser tuned to a vibrational mode of NH/sub 3/, C/sub 2/H/sub 4/, CH/sub 2/CHCN, or CH/sub 3/OH the breakdown potential decreases as much as 10-fold for laser pulse energies up to 35 J/cm/sup 2/. The subsequent 50--142-cm discharges are straight, stable, and reproducible. Analogous tests in D/sub 2/ and air yield only a small alteration of breakdown potential and do not cause a straight discharge. The expansion of the initial laser-heated gas has been modeled by the CHARTB hydrocode with the addition ofmore » the NH/sub 3/ equation of state in tabular and analytic form to that code. The breakdown characteristics and initial expansion stage confirm the earlier calculation of laser heating to 1900--2100 /sup 0/K. Experimental observations of the discharge evolution in NH/sub 3/ have measured (1) the radial expansion velocity by streak-camera photography of the H/sub ..beta../ emission zone, (2) the plasma temperature by the Niv/Niii line-ratio method, and (3) the electron-density profile by holographic interferometry. The central zone of the channel is heated to 5.5 eV and expands with a radial velocity of 1.0--1.2 mm/..mu..s for the case of a 27-kA discharge in 20 Torr of NH/sub 3/. Preliminary hydrocode simulations of the discharge show qualitative agreement with observations.« less

  1. Snowmelt discharge characteristics Sierra Nevada, California

    USGS Publications Warehouse

    Peterson, David; Smith, Richard; Stewart, Iris; Knowles, Noah; Soulard, Chris; Hager, Stephen

    2005-01-01

    Alpine snow is an important water resource in California and the western U.S. Three major features of alpine snowmelt are the spring pulse (the first surge in snowmelt-driven river discharge in spring), maximum snowmelt discharge, and base flow (low river discharge supported by groundwater in fall). A long term data set of hydrologic measurements at 24 gage locations in 20 watersheds in the Sierra Nevada was investigated to relate patterns of snowmelt with stream discharge In wet years, the daily variations in snowmelt discharge at all the gage locations in the Sierra Nevada correlate strongly with the centrally located Merced River at Happy Isles, Yosemite National Park (i.e., in 1983, the mean of the 23 correlations was R= 0.93 + 0.09) ; in dry years, however, this correlation breaks down (i.e., in year 1977, R=0.72 + 0.24). A general trend towards earlier snowmelt was found and modeled using correlations with the timing of the spring pulse and the river discharge center of mass. For the 24 river and creek gage locations in this study, the spring pulse appeared to be a more sensitive measure of early snowmelt than the center of mass. The amplitude of maximum daily snowmelt discharge correlates strongly with initial snow water equivalent. Geologic factors, base rock permeability and soil-to-bedrock ratio, influence snowmelt flow pathways. Although both surface and ground water flows and water levels increase in wet years compared to dry years, the increase was greater for surface water in a watershed with relatively impermeable base rock than for surface water in a watershed with highly permeable base rock The relation was the opposite for base flow (ground water). The increase was greater for groundwater in a watershed with permeable rock compared to ground water in a watershed with impermeable rock. A similar, but weaker, surface/groundwater partitioning was observed in relatively impermeable granitic watersheds with differing soil-to-bedrock ratios. The increase in surface flow was greater in a watershed with a low, compared to a high, soil-to-bedrock ratio; whereas the increase in ground water flow was greater in a watershed with a high, compared to a low, soil-to-bedrock ratio. Transects that include long-term observations of shallow well-water depth and chemistry would complement traditional hydroclimate data and provide a more complete understanding of hydrologic controls of snowmelt.

  2. A MEMS-enabled 3D zinc-air microbattery with improved discharge characteristics based on a multilayer metallic substructure

    NASA Astrophysics Data System (ADS)

    Armutlulu, A.; Fang, Y.; Kim, S. H.; Ji, C. H.; Bidstrup Allen, S. A.; Allen, M. G.

    2011-10-01

    This paper reports the design, fabrication and testing of a three-dimensional zinc-air microbattery with improved areal energy density and areal capacity, particularly at high discharge rates. The device is based on a multilayer, micron-scale, low-resistance metallic skeleton with an improved surface area. This skeleton consists of alternating Cu and Ni layers supporting Zn as electrodeposited anode electrode, and provides a high surface area, low-resistance path for electron transfer. A proof-of-concept zinc-air microbattery based on this technology was developed, characterized and compared with its two-dimensional thin-film counterparts fabricated on the same footprint area with equal amount of the Zn anode electrode. Using this approach, we were able to improve a single-layer initial structure with a surface area of 1.3 mm2 to a scaffold structure with ten layers having a surface area of 15 mm2. Discharging through load resistances ranging from 100 to 3000 Ω, the areal energy density and areal capacity of the microbattery were measured as 2.5-3 mWh cm-2 and ~2.5 mAh cm-2, respectively.

  3. Nanodisperse transition metal electrodes (NTME) for electrochemical cells

    DOEpatents

    Striebel, Kathryn A.; Wen, Shi-Jie

    2000-01-01

    Disclosed are transition metal electrodes for electrochemical cells using gel-state and solid-state polymers. The electrodes are suitable for use in primary and secondary cells. The electrodes (either negative electrode or positive electrode) are characterized by uniform dispersion of the transition metal at the nanoscale in the polymer. The transition metal moiety is structurally amorphous, so no capacity fade should occur due to lattice expansion/contraction mechanisms. The small grain size, amorphous structure and homogeneous distribution provide improved charge/discharge cycling performance, and a higher initial discharge rate capability. The cells can be cycled at high current densities, limited only by the electrolyte conductivity. A method of making the electrodes (positive and negative), and their usage in electrochemical cells are disclosed.

  4. Pahoehoe and aa in Hawaii: volumetric flow rate controls the lava structure

    NASA Astrophysics Data System (ADS)

    Rowland, Scott K.; Walker, George Pl

    1990-11-01

    The historical records of Kilauea and Mauna Loa volcanoes reveal that the rough-surfaced variety of basalt lava called aa forms when lava flows at a high volumetric rate (>5 10 m3/s), and the smooth-surfaced variety called pahoehoe forms at a low volumetric rate (<5 10 m3/s). This relationship is well illustrated by the 1983 1990 and 1969 1974 eruptions of Kilauea and the recent eruptions of Mauna Loa. It is also illustrated by the eruptions that produced the remarkable paired flows of Mauna Loa, in which aa formed during an initial short period of high discharge rate (associated with high fountaining) and was followed by the eruption of pahoehoe over a sustained period at a low discharge rate (with little or no fountaining). The finest examples of paired lava flows are those of 1859 and 1880 1881. We attribute aa formation to rapid and concentrated flow in open channels. There, rapid heat loss causes an increase in viscosity to a threshold value (that varies depending on the actual flow velocity) at which, when surface crust is torn by differential flow, the underlying lava is unable to move sufficiently fast to heal the tear. We attribute pahoehoe formation to the flowage of lava at a low volumetric rate, commonly in tubes that minimize heat loss. Flow units of pahoehoe are small (usually <1 m thick), move slowly, develop a chilled skin, and become virtually static before the viscosity has risen, to the threshold value. We infer that the high-discharge-rate eruptions that generate aa flows result from the rapid emptying of major or subsidiary magma chambers. Rapid near-surface vesiculation of gas-rich magma leads to eruptions with high discharge rates, high lava fountains, and fast-moving channelized flows. We also infer that long periods of sustained flow at a low discharge rate, which favor pahoehoe, result from the development of a free and unimpeded pathway from the deep plumbing system of the volcano and the separation of gases from the magma before eruption. Achievement of this condition requires one or more episodes of rapid magma excursion through the rift zone to establish a stable magma pathway.

  5. Statistical considerations in estimating organism concentrations in ballast water discharges

    EPA Science Inventory

    Sampling probabilities may affect the practical use of different ballast water performance standards which establish the acceptable concentration of organisms in ballast discharges. The International Maritime Organization (IMO) has initiated a ballast water standard of <10 viabl...

  6. A Corona Discharge Initiated Electrochemical Electrospray Ionization Technique

    PubMed Central

    Lloyd, John R.; Hess, Sonja

    2009-01-01

    We report here the development of a corona discharge (CD) initiated electrochemical (EC) electrospray ionization (ESI) technique using a standard electrospray ion source. This is a new ionization technique distinct from ESI, electrochemistry inherent to ESI, APCI, and techniques using hydroxyl radicals produced under atmospheric pressure conditions. By maximizing the observable CD at the tip of a stainless steel ESI capillary, efficient electrochemical oxidation of electrochemically active compounds is observed. For electrochemical oxidation to be observed, the ionization potential of the analyte must be lower than Fe. Ferrocene labeled compounds were chosen as the electrochemically active moiety. The electrochemical cell in the ESI source was robust and generated ions with selectivity according to the ionization potential of the analytes and up to zeptomolar sensitivity. Our results indicate that CD initiated electrochemical ionization has the potential to become a powerful technique to increase the dynamic range, sensitivity and selectivity of ESI experiments. Synopsis Using a standard ESI source a corona discharge initiated electrochemical ionization technique was established resulting from the electrochemistry occurring at the CD electrode surface. PMID:19747843

  7. Predictors of Post-concussion Rehabilitation Outcomes at Three-month Follow-up.

    PubMed

    Scott, Katie L; Strong, Carrie-Ann H; Gorter, Bethany; Donders, Jacobus

    2016-01-01

    To determine factors related to three-month follow-up outcomes for individuals participating in an outpatient rehabilitative treatment program for mild traumatic brain injury (TBI). Fifty participants underwent neuropsychological screening prior to treatment initiation and completed the Mayo-Portland Adaptability Inventory-4 (MPAI-4) at treatment initiation, discharge from treatment, and three months following discharge. Regression models indicated that information garnered from the neuropsychological screening prior to treatment initiation (e.g., mood symptoms and prior psychiatric history) accounted for unique variance in three-month post-discharge outcomes on several MPAI-4 subscales. Specifically, after controlling for baseline MPAI-4 ratings, higher Beck Depression Inventory-second edition (BDI-II) scores were associated with worse MPAI-4 Ability scores at three-month follow-up, and the presence of a psychiatric history was associated with worse MPAI-4 Adjustment scores at three-month follow-up. Neuropsychological screening prior to the initiation of treatment for mild TBI can help to identify patients who may be at greater risk for poorer rehabilitation outcomes, thus allowing for the implementation of specific interventions to address these risk factors.

  8. GAS DISCHARGE DEVICES

    DOEpatents

    Jefferson, S.

    1958-11-11

    An apparatus utilized in introducing tritium gas into envelope of a gas discharge device for the purpose f maintaining the discharge path in ionized condition is described. ln addition to the cathode and anode, the ischarge device contains a zirconium or tantalum ilament arranged for external excitation and a metallic seed containing tritium, and also arranged to have a current passed through it. Initially, the zirconium or tantalum filament is vaporized to deposit its material adjacent the main discharge region. Then the tritium gas is released and, due to its affinity for the first released material, it deposits in the region of the main discharge where it is most effective in maintaining the discharge path in an ionized condition.

  9. Production and study of high-beta plasma confined by a superconducting dipole magneta)

    NASA Astrophysics Data System (ADS)

    Garnier, D. T.; Hansen, A.; Mauel, M. E.; Ortiz, E.; Boxer, A. C.; Ellsworth, J.; Karim, I.; Kesner, J.; Mahar, S.; Roach, A.

    2006-05-01

    The Levitated Dipole Experiment (LDX) [J. Kesner et al., in Fusion Energy 1998, 1165 (1999)] is a new research facility that is exploring the confinement and stability of plasma created within the dipole field produced by a strong superconducting magnet. Unlike other configurations in which stability depends on curvature and magnetic shear, magnetohydrodynamic stability of a dipole derives from plasma compressibility. Theoretically, the dipole magnetic geometry can stabilize a centrally peaked plasma pressure that exceeds the local magnetic pressure (β>1), and the absence of magnetic shear allows particle and energy confinement to decouple. In initial experiments, long-pulse, quasi-steady-state microwave discharges lasting more than 10s have been produced that are consistent with equilibria having peak beta values of 20%. Detailed measurements have been made of discharge evolution, plasma dynamics and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. In these initial experiments, the high-field superconducting floating coil was supported by three thin supports. The plasma is created by multifrequency electron cyclotron resonance heating at 2.45 and 6.4GHz, and a population of energetic electrons, with mean energies above 50keV, dominates the plasma pressure. Creation of high-pressure, high-beta plasma is possible only when intense hot electron interchange instabilities are stabilized by sufficiently high background plasma density. A dramatic transition from a low-density, low-beta regime to a more quiescent, high-beta regime is observed when the plasma fueling rate and confinement time become sufficiently large.

  10. Experimental demonstration of plasma startup by coaxial helicity injection

    NASA Astrophysics Data System (ADS)

    Raman, R.; Jarboe, T. R.; Nelson, B. A.; Hamp, W. T.; Izzo, V. A.; O'Neill, R. G.; Redd, A. J.; Sieck, P. E.; Smith, R. J.

    2004-05-01

    Experimental results on the transfer of a coaxial-helicity-injection (CHI) produced discharge to inductive operation are reported. CHI assisted plasma startup is more robust than inductive only operation and reduces volt-seconds consumption. After handoff to inductive operation, the initial 100 kA of CHI produced current drops to 50 kA, then ramps up to 180 kA, using only 30 mVs, about 40% higher than that produced by induction alone. Results show that initiation of CHI discharges at lower densities produce higher levels of coupling current. Coupling a CHI produced discharge to induction from a precharged central solenoid has produced record currents of 290 kA using only 52 mWb of central solenoid flux. CHI discharges can also be generated while the central transformer is in the process of being precharged, during which period it induces a negative loop voltage on the CHI discharge. These significant results were obtained on the Helicity Injected Torus-II (HIT-II) [T.R. Jarboe, Fusion Technol. 15, 7 (1989)] spherical torus experiment (major/minor radius of 0.3/0.2 m and elongation of 1.5).

  11. Molecular Hysteresis of Dissolved Organic Matter in the Connecticut River Watershed

    NASA Astrophysics Data System (ADS)

    Wagner, S.; Hoyle, J. B.; Matt, S.; Raymond, P. A.; Saiers, J. E.; Dittmar, T.; Stubbins, A.

    2017-12-01

    Rainfall-runoff processes have emerged as key controllers of the quantity and quality of terrestrial dissolved organic matter (DOM) exported from the landscape to inland waters. Hydrological events result in increased river discharge and a concomitant release of large amounts of DOM into fluvial networks. This study is part of a Macrosystems project which aims to test the Pulse-Shunt Concept: where rivers are converted from active to passive pipes during high discharge events ("pulse"), transporting labile, terrestrial DOM downstream ("shunt"), and relocating biogeochemical hotspots for DOM from the upper to the lower reaches of the watershed. The primary objective of our study was to track hysteretic changes in riverine DOM molecular composition over the course of a storm event. Samples were collected from nested watersheds in the Passumpsic River catchment, a tributary of the Connecticut River (USA). High resolution monitoring (via in-situ sondes) and high frequency collection of discreet samples (for FT-ICR/MS and other analyses) was necessary to capture short-term, hydrologically-driven variations in DOM concentration and composition. At the onset of the discharge event, we observed a unique DOM signature, enriched in aliphatic, and potentially biolabile, DOM. During peak discharge, and along the falling limb of the hydrograph, an aromatic, terrestrial-type DOM signature was more prevalent. These initial findings support the pulse-shunt hypothesis, providing evidence for the release of labile forms of DOM into rivers during the onset of a storm event, which apparently persists across low-to-high stream orders. Insights into the molecular hysteresis of fluvial DOM spotlights the impact of watershed hydrology on biogeochemical cycling in river networks.

  12. Clinical prediction rule for delayed hemothorax after minor thoracic injury: a multicentre derivation and validation study

    PubMed Central

    Émond, Marcel; Guimont, Chantal; Chauny, Jean-Marc; Daoust, Raoul; Bergeron, Éric; Vanier, Laurent; Moore, Lynne; Plourde, Miville; Kuimi, Batomen; Boucher, Valérie; Allain-Boulé, Nadine; Le Sage, Natalie

    2017-01-01

    Background: About 75% of patients with minor thoracic injury are discharged after an emergency department visit. However, complications such as delayed hemothorax can occur. We sought to derive and validate a clinical decision rule to predict hemothorax in patients discharged from the emergency department. Methods: We conducted a 6-year prospective cohort study in 4 university-affiliated emergency departments. Patients aged 16 years or older presenting with a minor thoracic injury were assessed at 5 time points (initial visit and 7, 14, 30 and 90 d after the injury). Radiologists' reports were reviewed for the presence of hemothorax. We used log-binomial regression models to identify predictors of hemothorax. Results: A total of 1382 patients were included: 830 in the derivation phase and 552 in the validation phase. Of these, 151 (10.9%) had hemothorax at the 14-day follow-up. Patients 65 years of age or older represented 25.3% (210/830) and 23.7% (131/552) of the derivation and validation cohorts, respectively. The final clinical decision rule included a combination of age (> 70 yr, 2 points; 45-70 yr, 1 point), fracture of any high to mid thorax rib (ribs 3-9, 2 points) and presence of 3 or more rib fractures (1 point). Twenty (30.8%) of the 65 high-risk patients (score ≥ 4) experienced hemothorax during the follow-up period. The clinical decision rule had a high specificity (90.7%, 95% confidence interval 87.7%-93.1%) in this high-risk group, thus guiding appropriate post-emergency care. Interpretation: One patient out of every 10 presented with delayed hemothorax after discharge from the emergency department. Implementation of this validated clinical decision rule for minor thoracic injury could guide emergency discharge plans. PMID:28611156

  13. Delineating saturated conduit patterns and dimensions in the upper Floridan aquifer through numerical groundwater flow modeling (Invited)

    NASA Astrophysics Data System (ADS)

    Kincaid, T. R.; Meyer, B. A.

    2009-12-01

    In groundwater flow modeling, aquifer permeability is typically defined through model calibration. Since the pattern and size of conduits are part of a karstic permeability framework, those parameters should be constrainable through the same process given a sufficient density of measured conditions. H2H Associates has completed a dual-permeability steady-state model of groundwater flow through the western Santa Fe River Basin, Florida from which a 380.9 km network of saturated conduits was delineated through model calibration to heads and spring discharges. Two calibration datasets were compiled describing average high-water and average low-water conditions based on heads at 145 wells and discharge from 18 springs for the high-water scenario and heads at 188 wells and discharge from 9 springs for the low-water scenario. An initial conduit network was defined by assigning paths along mapped conduits and inferring paths along potentiometric troughs between springs and swallets that had been connected by groundwater tracing. These initial conduit assignments accounted for only 13.75 and 34.1 km of the final conduit network respectively. The model was setup using FEFLOW™ where conduits were described as discrete features embedded in a porous matrix. Flow in the conduits was described by the Manning-Strickler equation where variables for conduit area and roughness were used to adjust the volume and velocity of spring flows. Matrix flow was described by Darcy’s law where hydraulic conductivity variations were limited to three geologically defined internally homogeneous zones that ranged from ~2E-6 m/s to ~4E-3 m/s. Recharge for both the high-water and low-water periods was determined through a water budget analysis where variations were restricted to nine zones defined by land-use. All remaining variations in observed head were then assumed to be due to conduits. The model was iteratively calibrated to the high-water and low-water datasets wherein the location, size and roughness of the conduits were assigned as needed to accurately simulate observed heads and spring discharges while bounding simulated velocities by the tracer test results. Conduit diameters were adjusted to support high-water spring discharges but the locations were best determined by calibration to the low-water head field. The final model calibrated to within 5% of the total head change across the model region at 143 of the 145 wells in the high-water scenario and at 176 of the 188 wells in the low-water scenario. Simulated spring discharges fell within 13% of the observed range under high-water conditions and to within 100% of the observed range under low-water conditions. Simulated velocities ranged from as low as 10-4 m/day in the matrix to as high as 10+3 m/day in the largest conduits. The significance of these results that we emphasize here is two-fold. First, plausible karstic groundwater flow conditions can be reasonably simulated if adequate efforts are made to include springs, swallets, caves, and traced flow paths. And second, detailed saturated conduit networks can be delineated from careful evaluation of hydraulic head data particularly when dense datasets can be constructed by correlating values obtained from different wells under similar hydraulic periods.

  14. Constraints on Lake Agassiz discharge through the late-glacial Champlain Sea (St. Lawrence Lowlands, Canada) using salinity proxies and an estuarine circulation model

    USGS Publications Warehouse

    Katz, B.; Najjar, R.G.; Cronin, T.; Rayburn, J.; Mann, M.E.

    2011-01-01

    During the last deglaciation, abrupt freshwater discharge events from proglacial lakes in North America, such as glacial Lake Agassiz, are believed to have drained into the North Atlantic Ocean, causing large shifts in climate by weakening the formation of North Atlantic Deep Water and decreasing ocean heat transport to high northern latitudes. These discharges were caused by changes in lake drainage outlets, but the duration, magnitude and routing of discharge events, factors which govern the climatic response to freshwater forcing, are poorly known. Abrupt discharges, called floods, are typically assumed to last months to a year, whereas more gradual discharges, called routing events, occur over centuries. Here we use estuarine modeling to evaluate freshwater discharge from Lake Agassiz and other North American proglacial lakes into the North Atlantic Ocean through the St. Lawrence estuary around 11.5 ka BP, the onset of the Preboreal oscillation (PBO). Faunal and isotopic proxy data from the Champlain Sea, a semi-isolated, marine-brackish water body that occupied the St. Lawrence and Champlain Valleys from 13 to 9 ka, indicate salinity fell about 7-8 (range of 4-11) around 11.5 ka. Model results suggest that minimum (1600 km3) and maximum (9500 km3) estimates of plausible flood volumes determined from Lake Agassiz paleoshorelines would produce the proxy-reconstructed salinity decrease if the floods lasted <1 day to 5 months and 1 month to 2 years, respectively. In addition, Champlain Sea salinity responds very quickly to the initiation (within days) and cessation (within weeks) of flooding events. These results support the hypothesis that a glacial lake flood, rather than a sustained routing event, discharged through the St. Lawrence Estuary during the PBO. ?? 2011 Elsevier Ltd.

  15. Modeling of non-thermal plasma in flammable gas mixtures

    NASA Astrophysics Data System (ADS)

    Napartovich, A. P.; Kochetov, I. V.; Leonov, S. B.

    2008-07-01

    An idea of using plasma-assisted methods of fuel ignition is based on non-equilibrium generation of chemically active species that speed up the combustion process. It is believed that gain in energy consumed for combustion acceleration by plasmas is due to the non-equilibrium nature of discharge plasma, which allows radicals to be produced in an above-equilibrium amount. Evidently, the size of the effect is strongly dependent on the initial temperature, pressure, and composition of the mixture. Of particular interest is comparison between thermal ignition of a fuel-air mixture and non-thermal plasma initiation of the combustion. Mechanisms of thermal ignition in various fuel-air mixtures have been studied for years, and a number of different mechanisms are known providing an agreement with experiments at various conditions. The problem is -- how to conform thermal chemistry approach to essentially non-equilibrium plasma description. The electric discharge produces much above-equilibrium amounts of chemically active species: atoms, radicals and ions. The point is that despite excess concentrations of a number of species, total concentration of these species is far below concentrations of the initial gas mixture. Therefore, rate coefficients for reactions of these discharge produced species with other gas mixture components are well known quantities controlled by the translational temperature, which can be calculated from the energy balance equation taking into account numerous processes initiated by plasma. A numerical model was developed combining traditional approach of thermal combustion chemistry with advanced description of the plasma kinetics based on solution of electron Boltzmann equation. This approach allows us to describe self-consistently strongly non-equilibrium electric discharge in chemically unstable (ignited) gas. Equations of pseudo-one-dimensional gas dynamics were solved in parallel with a system of thermal chemistry equations, kinetic equations for charged particles (electrons, positive and negative ions), and with the electric circuit equation. The electric circuit comprises power supply, ballast resistor connected in series with the discharge and capacity. Rate coefficients for electron-assisted reactions were calculated from solving the two-term spherical harmonic expansion of the Boltzmann equation. Such an approach allows us to describe influence of thermal chemistry reactions (burning) on the discharge characteristics. Results of comparison between the discharge and thermal ignition effects for mixtures of hydrogen or ethylene with dry air will be reported. Effects of acceleration of ignition by discharge plasma will be analyzed. In particular, the role of singlet oxygen produced effectively in the discharge in ignition speeding up will be discussed.

  16. Decreasing Emergency Department Walkout Rate and Boarding Hours by Improving Inpatient Length of Stay.

    PubMed

    Artenstein, Andrew W; Rathlev, Niels K; Neal, Douglas; Townsend, Vernette; Vemula, Michael; Goldlust, Sheila; Schmidt, Joseph; Visintainer, Paul

    2017-10-01

    Patient progress, the movement of patients through a hospital system from admission to discharge, is a foundational component of operational effectiveness in healthcare institutions. Optimal patient progress is a key to delivering safe, high-quality and high-value clinical care. The Baystate Patient Progress Initiative (BPPI), a cross-disciplinary, multifaceted quality and process improvement project, was launched on March 1, 2014, with the primary goal of optimizing patient progress for adult patients. The BPPI was implemented at our system's tertiary care, academic medical center, a high-volume, high-acuity hospital that serves as a regional referral center for western Massachusetts. The BPPI was structured as a 24-month initiative with an oversight group that ensured collaborative goal alignment and communication of operational teams. It was organized to address critical aspects of a patient's progress through his hospital stay and to create additional inpatient capacity. The specific goal of the BPPI was to decrease length of stay (LOS) on the inpatient adult Hospital Medicine service by optimizing an interdisciplinary plan of care and promoting earlier departure of discharged patients. Concurrently, we measured the effects on emergency department (ED) boarding hours per patient and walkout rates. The BPPI engaged over 300 employed clinicians and non-clinicians in the work. We created increased inpatient capacity by implementing daily interdisciplinary bedside rounds to proactively address patient progress; during the 24 months, this resulted in a sustained rate of discharge orders written before noon of more than 50% and a decrease in inpatient LOS of 0.30 days (coefficient: -0.014, 95% CI [-0.023, -0.005] P< 0.005). Despite the increase in ED patient volumes and severity of illness over the same time period, ED boarding hours per patient decreased by approximately 2.1 hours (coefficient: -0.09; 95% CI [-0.15, -0.02] P = 0.007). Concurrently, ED walkout rates decreased by nearly 32% to a monthly mean of 0.4 patients (coefficient: 0.4; 95% CI [-0.7, -0.1] P= 0.01). The BPPI realized significant gains in patient progress for adult patients by promoting earlier discharges before noon and decreasing overall inpatient LOS. Concurrently, ED boarding hours per patient and walkout rates decreased.

  17. Dynamic interneuron-principal cell interplay leads to a specific pattern of in vitro ictogenesis.

    PubMed

    Lévesque, Maxime; Chen, Li-Yuan; Hamidi, Shabnam; Avoli, Massimo

    2018-07-01

    Ictal discharges induced by 4-aminopyridine in the in vitro rodent entorhinal cortex present with either low-voltage fast or sudden onset patterns. The role of interneurons in initiating low-voltage fast onset ictal discharges is well established but the processes leading to sudden onset ictal discharges remain unclear. We analysed here the participation of interneurons (n = 75) and principal cells (n = 13) in the sudden onset pattern by employing in vitro tetrode wire recordings in the entorhinal cortex of brain slices from Sprague-Dawley rats. Ictal discharges emerged from a background of frequently occurring interictal spikes that were associated to a specific interneuron/principal cell interplay. High rates of interneuron firing occurred 12 ms before interictal spike onset while principal cells fired later during low interneuron firing. In contrast, the onset of sudden ictal discharges was characterized by increased firing from principal cells 627 ms before ictal onset whereas interneurons increased their firing rates 161 ms before ictal onset. Our data show that sudden onset ictogenesis is associated with frequently occurring interictal spikes resting on the interplay between interneurons and principal cells while ictal discharges stem from enhanced principal cell firing leading to increased interneuron activity. These findings indicate that specific patterns of interactions between interneurons and principal cells shape interictal and ictal discharges with sudden onset in the rodent entorhinal cortex. We propose that specific neuronal interactions lead to the generation of distinct onset patterns in focal epileptic disorders. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Value of mammography and breast ultrasound in male patients with nipple discharge.

    PubMed

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Short Haul Civil Tiltrotor Contingency Power System Preliminary Design

    NASA Technical Reports Server (NTRS)

    Eames, David J. H.

    2006-01-01

    Single Langmuir probe measurements are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring cusp ion thruster over a range of thruster operating conditions encompassing the high-power half of the NASA throttling table. The Langmuir probe data were analyzed with two separate methods. All data were analyzed initially assuming an electron population consisting of Maxwellian electrons only. The on-axis data were then analyzed assuming both Maxwellian and primary electrons. Discharge plasma data taken with beam extraction exhibit a broadening of the higher electron temperature plume boundary compared to similar discharge conditions without beam extraction. The opposite effect is evident with the electron/ion number density as the data without began, extraction appears to be more collimated than the corresponding data with beam extraction. Primary electron energy and number densities are presented for one operating condition giving an order of magnitude of their value and the error associated with this calculation.

  20. Effects of F-treatment on degradation of Mg 2Ni electrode fabricated by mechanical alloying

    NASA Astrophysics Data System (ADS)

    Kim, Jun Sung; Lee, Chang Rae; Choi, Jae Woong; Kang, Sung Goon

    The effects of surface fluorination on the electrochemical charge-discharge properties of a Mg 2Ni electrode, prepared by mechanical alloying in Ni-MH batteries are investigated. After 20 h milling, Mg and Ni powder form nanocrystalline Mg 2Ni. The discharge capacity of this alloy increases greatly on the initial cycle but, due to the formation of a Mg(OH) 2 passive layer, displays rapid degradation in alkaline solution within 10 cycles. In a 6 M KOH+ x M KF electrolyte ( x=0.5, 1, and 2), a continuous and stable fluorinated layer is formed and the durability of the Mg 2Ni electrode increases marketly and a high rate discharge capability is obtained (90-100 mAh/g). Addition of 2 M KF leads to the highest durability of all the electrodes tested. The improvement is due to a thin MgF 2—flourinated layer, which reduces the charge-transfer resistance and protects the Mg 2Ni electrode from forming a Mg(OH) 2 layer.

  1. Effects of solution volume on hydrogen production by pulsed spark discharge in ethanol solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xin, Y. B.; Sun, B., E-mail: sunb88@dlmu.edu.cn; Zhu, X. M.

    2016-07-15

    Hydrogen production from ethanol solution (ethanol/water) by pulsed spark discharge was optimized by varying the volume of ethanol solution (liquid volume). Hydrogen yield was initially increased and then decreased with the increase in solution volume, which achieved 1.5 l/min with a solution volume of 500 ml. The characteristics of pulsed spark discharge were studied in this work; the results showed that the intensity of peak current, the rate of current rise, and energy efficiency of hydrogen production can be changed by varying the volume of ethanol solution. Meanwhile, the mechanism analysis of hydrogen production was accomplished by monitoring the process of hydrogenmore » production and the state of free radicals. The analysis showed that decreasing the retention time of gas production and properly increasing the volume of ethanol solution can enhance the hydrogen yield. Through this research, a high-yield and large-scale method of hydrogen production can be achieved, which is more suitable for industrial application.« less

  2. Xenon plasma sustained by pulse-periodic laser radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudoy, I. G.; Solovyov, N. G.; Soroka, A. M.

    2015-10-15

    The possibility of sustaining a quasi-stationary pulse-periodic optical discharge (POD) in xenon at a pressure of p = 10–20 bar in a focused 1.07-μm Yb{sup 3+} laser beam with a pulse repetition rate of f{sub rep} ⩾ 2 kHz, pulse duration of τ ⩾ 200 μs, and power of P = 200–300 W has been demonstrated. In the plasma development phase, the POD pulse brightness is generally several times higher than the stationary brightness of a continuous optical discharge at the same laser power, which indicates a higher plasma temperature in the POD regime. Upon termination of the laser pulse,more » plasma recombines and is then reinitiated in the next pulse. The initial absorption of laser radiation in successive POD pulses is provided by 5p{sup 5}6s excited states of xenon atoms. This kind of discharge can be applied in plasma-based high-brightness broadband light sources.« less

  3. Research on the discharge characteristics for water tree in crosslinked polyethylene cable based on plasma-chemical model

    NASA Astrophysics Data System (ADS)

    Fan, Yang; Qi, Yang; Bing, Gao; Rong, Xia; Yanjie, Le; Iroegbu, Paul Ikechukwu

    2018-03-01

    Water tree is the predominant defect in high-voltage crosslinked polyethylene cables. The microscopic mechanism in the discharge process is not fully understood; hence, a drawback is created towards an effective method to evaluate the insulation status. In order to investigate the growth of water tree, a plasma-chemical model is developed. The dynamic characteristics of the discharge process including voltage waveform, current waveform, electron density, electric potential, and electric field intensity are analyzed. Our results show that the distorted electric field is the predominant contributing factor of electron avalanche formation, which inevitably leads to the formation of pulse current. In addition, it is found that characteristic parameters such as the pulse width and pulse number have a great relevance to the length of water tree. Accordingly, the growth of water tree can be divided into the initial stage, development stage, and pre-breakdown stage, which provides a reference for evaluating the deteriorated stages of crosslinked polyethylene cables.

  4. Multipole gas thruster design. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Isaacson, G. C.

    1977-01-01

    The development of a low field strength multipole thruster operating on both argon and xenon is described. Experimental results were obtained with a 15-cm diameter multipole thruster and are presented for a wide range of discharge-chamber configurations. Minimum discharge losses were 300-350 eV/ion for argon and 200-250 eV/ion for xenon. Ion beam flatness parameters in the plane of the accelerator grid ranged from 0.85 to 0.93 for both propellants. Thruster performance is correlated for a range of ion chamber sizes and operating conditions as well as propellant type and accelerator system open area. A 30-cm diameter ion source designed and built using the procedure and theory presented here-in is shown capable of low discharge losses and flat ion-beam profiles without optimization. This indicates that by using the low field strength multipole design, as well as general performance correlation information provided herein, it should be possible to rapidly translate initial performance specifications into easily fabricated, high performance prototypes.

  5. The effect of time to defibrillation and targeted temperature management on functional survival after out-of-hospital cardiac arrest.

    PubMed

    Drennan, Ian R; Lin, Steve; Thorpe, Kevin E; Morrison, Laurie J

    2014-11-01

    Cardiac arrest physiology has been proposed to occur in three distinct phases: electrical, circulatory and metabolic. There is limited research evaluating the relationship of the 3-phase model of cardiac arrest to functional survival at hospital discharge. Furthermore, the effect of post-cardiac arrest targeted temperature management (TTM) on functional survival during each phase is unknown. To determine the effect of TTM on the relationship between the time of initial defibrillation during each phase of cardiac arrest and functional survival at hospital discharge. This was a retrospective observational study of consecutive adult (≥18 years) out-of-hospital cardiac arrest (OHCA) patients with initial shockable rhythms. Included patients obtained a return of spontaneous circulation (ROSC) and were eligible for TTM. Multivariable logistic regression was used to determine predictors of functional survival at hospital discharge. There were 20,165 OHCA treated by EMS and 871 patients were eligible for TTM. Of these patients, 622 (71.4%) survived to hospital discharge and 487 (55.9%) had good functional survival. Good functional survival was associated with younger age (OR 0.94; 95% CI 0.93-0.95), shorter times from collapse to initial defibrillation (OR 0.73; 95% CI 0.65-0.82), and use of post-cardiac arrest TTM (OR 1.49; 95% CI 1.07-2.30). Functional survival decreased during each phase of the model (65.3% vs. 61.7% vs. 50.2%, P<0.001). Functional survival at hospital discharge was associated with shorter times to initial defibrillation and was decreased during each successive phase of the 3-phase model. Post-cardiac arrest TTM was associated with improved functional survival. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Meteorological Aspects of Two Modes of Lightning Triggered Upward Lightning (LTUL) Events in Sprite-Producing MCSs

    NASA Technical Reports Server (NTRS)

    Lyons, W. A.; Nelson, T. E.; Warner, T. A.; Lang, T. J.; Cummins, K.; Quick, M.; Rison, W.; Krehbiel, P.; Cummer, S. A.; Meyers, J.; hide

    2014-01-01

    During the 2013 convective storm season, a high resolution 3-D Lightning Mapping Array was deployed to north central Kansas (Cummins et al, this conference.) In conjunction with fixed and mobile camera systems and electric field mills, this allowed for detailed investigations of lightning induced upward lighting (LTUL) discharges from tall objects in the region, including wind turbines. Also, concurrent observations using a network of low-light cameras deployed over the central U.S. as part of the PhOCAL program detected transient luminous events (TLEs) above the Kansas LMA (KSLMA). During the night of 29-30 May 2013, waves of precipitation associated with several large MCSs traversing Kansas moved through the KSLMA domain. We focus on two LTUL events that exemplify two modes of upward lightning production from tall structures. At 0859Z, 30 May 2013, a nearby + 92 kA CG, with extensive in-cloud branching passing overhead a wind farm, was followed by complex LTUL discharges from four turbines. In addition, a sprite was confirmed by the Bennett, CO SpriteNet camera. The parent flash covered a very large area. It initiated near the MCS convective leading line 150 km to the south, and traveled into a stratiform precipitation maximum over the KSLMA. Typically when a +CG precedes an LTUL, the triggering component is either 1) the return stroke that traverses the leader network which initially forms near the towers or 2) new negative leader activity that develops once the return stroke reaches the end of the initial leader network that may not have initially been near the tower. In the latter case, the new leader development passes near the towers and triggers upward positive leaders similar to those associated with only an intracloud flash. The +CG return stroke may hit >10 km from the towers and the new leader development may travel extensive distances before getting close enough to the towers to trigger upward lightning. In this case, there was the typical long delay between the +CG return stroke and LTUL initiation (10s to 100s of ms). The parent lightning discharges for both sprites and LTULs have many common aspects and tend to occur in similar meteorological regimes, with the two phenomena often occurring together. An earlier LUTL, at 2320Z, 29 May 2013 was captured at 9900 fps by a Phantom camera in the PhOCAL mobile Lightning Investigation Vehicle (LIV). This discharge, exhibiting numerous recoil leaders, also occurred in a stratiform region some 50-100 km north of an MCS convective core. While there was no preceding +CG, there was an extensive network of IC channels, one of which passed overhead close to the turbine. These observations are consistent with the ongoing UPLIGHTS studies of LTULs from tall towers in Rapid City. While a +CG is usually involved (85% of the time), the LTUL occurs because of the associated extensive in cloud components passing over towers. The earlier case without a +CG typifies this second mode where the triggering component is a negative leader associated with the IC activity passing near the towers initiates the upward positive leaders. We will discuss the parent discharges, shown in their meteorological (radar and satellite) context, and attempt to better understand the charge structures present in both the convective and stratiform regions of the MCS. The sprite and its relationship to the parent discharge will similarly be discussed

  7. Yield of H2O2 in Gas-Liquid Phase with Pulsed DBD

    NASA Astrophysics Data System (ADS)

    Jiang, Song; Wen, Yiyong; Liu, Kefu

    2014-01-01

    Electric discharge in water can generate a large number of oxidants such as ozone, hydrogen peroxide and hydroxyl radicals. In this paper, a non-thermal plasma processing system was established by means of pulsed dielectric barrier discharge in gas-liquid phase. The electrodes of discharge reactor were staggered. The yield of H2O2 was enhanced after discharge. The effects of discharge time, discharge voltage, frequency, initial pH value, and feed gas were investigated. The concentration of hydrogen peroxide and ozone was measured after discharge. The experimental results were fully analyzed. The chemical reaction equations in water were given as much as possible. At last, the water containing Rhodamine B was tested in this system. The degradation rate came to 94.22% in 30 min.

  8. Performance of a 10 kV, 625 kA, 85 kJ energy discharge module utilizing a solid dielectric switch

    NASA Astrophysics Data System (ADS)

    Richardson, R. A.; Cravey, W. R.; Goerz, D. A.

    We have designed and tested an 87-kJ energy discharge system consisting of two 720-(mu)F, 11-kV capacitors discharged through parallel coaxial cables into a 250 nH load. Data will be presented on the current and voltage waveforms, with calculated values of the system inductance and resistance. The bank uses a solid dielectric switch punctured by an explosive bridge wire (EBW) to initiate the discharge. With the capacitors charged to 9 kV, a 625-kA peak current is sent through the load with a ringing frequency of 6.8 kHz. The coaxial cables used to transmit the current to the load are 3 m in length. Both RG-217 and YK-198 cable types were tested, which have an inductance of 74 nH/ft and 35 nH/ft respectively. Normal operation requires that each cable carry 52 kA. The cables were tested to 100 kA each by connecting fewer cables to the load, and gradually increasing the charge voltage. The solid dielectric switch was chosen for high reliability. Details of the switch will be describes and data on its performance will be presented.

  9. Quantifying Neonatal Sucking Performance: Promise of New Methods

    PubMed Central

    Capilouto, Gilson J.; Cunningham, Tommy J.; Mullineaux, David R.; Tamilia, Eleonora; Papadelis, Christos; Giannone, Peter J.

    2017-01-01

    Neonatal feeding has been traditionally understudied so guidelines and evidence-based support for common feeding practices are limited. A major contributing factor to the paucity of evidence-based practice in this area has been the lack of simple-to-use, low-cost tools for monitoring sucking performance. We describe new methods for quantifying neonatal sucking performance that hold significant clinical and research promise. We present early results from an ongoing study investigating neonatal sucking as a marker of risk for adverse neurodevelopmental outcomes. We include quantitative measures of sucking performance to better understand how movement variability evolves during skill acquisition. Results showed the coefficient of variation of suck duration was significantly different between preterm neonates at high risk for developmental concerns (HRPT) and preterm neonates at low risk for developmental concerns (LRPT). For HRPT, results indicated the coefficient of variation of suck smoothness increased from initial feeding to discharge and remained significantly greater than healthy full-term newborns (FT) at discharge. There was no significant difference in our measures between FT and LRPT at discharge. Our findings highlight the need to include neonatal sucking assessment as part of routine clinical care in order to capture the relative risk of adverse neurodevelopmental outcomes at discharge. PMID:28324904

  10. Dual-protection of a graphene-sulfur composite by a compact graphene skin and an atomic layer deposited oxide coating for a lithium-sulfur battery

    NASA Astrophysics Data System (ADS)

    Yu, Mingpeng; Wang, Aiji; Tian, Fuyang; Song, Hongquan; Wang, Yinshu; Li, Chun; Hong, Jong-Dal; Shi, Gaoquan

    2015-03-01

    A reduced graphene oxide (rGO)-sulfur composite aerogel with a compact self-assembled rGO skin was further modified by an atomic layer deposition (ALD) of ZnO or MgO layer, and used as a free-standing electrode material of a lithium-sulfur (Li-S) battery. The rGO skin and ALD-oxide coating worked as natural and artificial barriers to constrain the polysulfides within the cathode region. As a result, the Li-S battery based on this electrode material exhibited superior cycling stability, good rate capability and high coulombic efficiency. Furthermore, ALD-ZnO coating was tested for performance improvement and found to be more effective than ALD-MgO coating. The ZnO modified G-S electrode with 55 wt% sulfur loading delivered a maximum discharge capacity of 998 mA h g-1 at a current density of 0.2 C. A high capacity of 846 mA h g-1 was achieved after charging/discharging for 100 cycles with a coulombic efficiency of over 92%. In the case of using LiNO3 as a shuttle inhibitor, this electrode showed an initial discharge capacity of 796 mA h g-1 and a capacity retention of 81% after 250 cycles at a current density of 1 C with an average coulombic efficiency higher than 99.7%.A reduced graphene oxide (rGO)-sulfur composite aerogel with a compact self-assembled rGO skin was further modified by an atomic layer deposition (ALD) of ZnO or MgO layer, and used as a free-standing electrode material of a lithium-sulfur (Li-S) battery. The rGO skin and ALD-oxide coating worked as natural and artificial barriers to constrain the polysulfides within the cathode region. As a result, the Li-S battery based on this electrode material exhibited superior cycling stability, good rate capability and high coulombic efficiency. Furthermore, ALD-ZnO coating was tested for performance improvement and found to be more effective than ALD-MgO coating. The ZnO modified G-S electrode with 55 wt% sulfur loading delivered a maximum discharge capacity of 998 mA h g-1 at a current density of 0.2 C. A high capacity of 846 mA h g-1 was achieved after charging/discharging for 100 cycles with a coulombic efficiency of over 92%. In the case of using LiNO3 as a shuttle inhibitor, this electrode showed an initial discharge capacity of 796 mA h g-1 and a capacity retention of 81% after 250 cycles at a current density of 1 C with an average coulombic efficiency higher than 99.7%. Electronic supplementary information (ESI) available: Procedures of ALD operation, supplementary figures and details of theoretical simulations. See DOI: 10.1039/c5nr00166h

  11. Modeling carbonaceous particle formation in an argon graphite cathode dc discharge

    NASA Astrophysics Data System (ADS)

    Michau, A.; Lombardi, G.; Colina Delacqua, L.; Redolfi, M.; Arnas, C.; Bonnin, X.; Hassouni, K.

    2010-12-01

    We develop a model for the nucleation, growth and transport of carbonaceous dust particles in a non-reactive gas dc discharge where the carbon source is provided by cathode sputtering. We consider only the initial phase of the discharge when the dust charge density remains small with respect to the electron density. We find that an electric field reversal at the entrance of the negative glow region promotes trapping of negatively charged clusters and dust particles, confining them for long times in the plasma and favoring molecular growth. An essential ingredient for this process is electron attachment, which negatively charges the initially neutral clusters. We perform sensitivity studies on several number parameters: size of the largest molecular edifice, sticking coefficient, etc.

  12. Origin of Initial Current Peak in High Power Impulse Magnetron Sputtering and Verification by Non-Sputtering Discharge

    NASA Astrophysics Data System (ADS)

    Zhong-Zhen, Wu; Shu, Xiao; Sui-Han, Cui; Ricky, K. Y. Fu; Xiu-Bo, Tian; Paul, K. Chu; Feng, Pan

    2016-07-01

    Not Available Supported by the National Natural Science Foundation of China under Grant Nos 51301004 and U1330110, the Guangdong Innovative and Entrepreneurial Research Team Program under Grant No 2013N080, the Shenzhen Science and Technology Research Grant under Grant Nos JCYJ20140903102215536 and JCYJ20150828093127698, and the City University of Hong Kong Applied Research Grant under Grant No 9667104.

  13. Plasmachemical and heterogeneous processes in ozonizers with oxygen activation by a dielectric barrier discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankelevich, Yu. A., E-mail: ymankelevich@mics.msu.su; Voronina, E. N.; Poroykov, A. Yu.

    Plasmachemical and heterogeneous processes of generation and loss of ozone in the atmosphericpressure dielectric barrier discharge in oxygen are studied theoretically. Plasmachemical and electronic kinetics in the stage of development and decay of a single plasma filament (microdischarge) are calculated numerically with and without allowance for the effects of ozone vibrational excitation and high initial ozone concentration. The developed analytical approach is applied to determine the output ozone concentration taking into account ozone heterogeneous losses on the Al{sub 2}O{sub 3} dielectric surface. Using the results of quantummechanical calculations by the method of density functional theory, a multistage catalytic mechanism ofmore » heterogeneous ozone loss based on the initial passivation of a pure Al{sub 2}O{sub 3} surface by ozone and the subsequent interaction of O{sub 3} molecules with the passivated surface is proposed. It is shown that the conversion reaction 2O{sub 3} → 3O{sub 2} of a gas-phase ozone molecule with a physically adsorbed ozone molecule can result in the saturation of the maximum achievable ozone concentration at high specific energy depositions, the nonstationarity of the output ozone concentration, and its dependence on the prehistory of ozonizer operation.« less

  14. Rapid, efficient charging of lead-acid and nickel-zinc traction cells

    NASA Technical Reports Server (NTRS)

    Smithrick, J. J.

    1978-01-01

    Lead-acid and nickel-zinc traction cells were rapidly and efficiently charged using a high rate tapered direct current (HRTDC) charge method which could possibly be used for on-the-road service recharge of electric vehicles. The HRTDC method takes advantage of initial high cell charge acceptance and uses cell gassing rate and temperature as an indicator of charging efficiency. On the average, in these preliminary tests, 300 amp-hour nickel-zinc traction cells were given a HRTDC (initial current 500 amps, final current 100 amps) to 78 percent of rated amp-hour capacity within 53 minutes at an amp-hour efficiency of 92 percent and an energy efficiency of 52 percent. Three hundred amp-hour lead-acid traction cells were charged to 69 percent of rated amp-hour capacity within 46 minutes at an amp-hour efficiency of 91 percent with an energy efficiency of 64 percent. In order to find ways to further decrease the recharge times, the effect of periodically (0 to 400 Hz) pulse discharging cells during a constant current charging process (94% duty cycle) was investigated. Preliminary data indicate no significant effect of this type of pulse discharging during charge on charge acceptance of lead-acid or nickel-zinc cells.

  15. Graphene/Sulfur/Carbon Nanocomposite for High Performance Lithium-Sulfur Batteries

    PubMed Central

    Jin, Kangke; Zhou, Xufeng; Liu, Zhaoping

    2015-01-01

    Here, we report a two-step synthesis of graphene/sulfur/carbon ternary composite with a multilayer structure. In this composite, ultrathin S layers are uniformly deposited on graphene nanosheets and covered by a thin layer of amorphous carbon derived from β-cyclodextrin on the surface. Such a unique microstructure, not only improves the electrical conductivity of sulfur, but also effectively inhibits the dissolution of polysulfides during charging/discharging processes. As a result, this ternary nanocomposite exhibits excellent electrochemical performance. It can deliver a high initial discharge and charge capacity of 1410 mAh·g−1 and 1370 mAh·g−1, respectively, and a capacity retention of 63.8% can be achieved after 100 cycles at 0.1 C (1 C = 1675 mA·g−1). A relatively high specific capacity of 450 mAh·g−1 can still be retained after 200 cycles at a high rate of 2 C. The synthesis process introduced here is simple and broadly applicable to the modification of sulfur cathode for better electrochemical performance. PMID:28347077

  16. L-lactic acid and sodium p-toluenesulfonate co-doped polypyrrole for high performance cathode in sodium ion battery

    NASA Astrophysics Data System (ADS)

    Liao, Qishu; Hou, Hongying; Liu, Xianxi; Yao, Yuan; Dai, Zhipeng; Yu, Chengyi; Li, Dongdong

    2018-04-01

    In this work, polypyrrole (PPy) was co-doped with L-lactic acid (LA) and sodium p-toluenesulfonate (TsONa) for high performance cathode in sodium ion battery (SIB) via facile one-step electropolymerization on Fe foil. The as-synthesized LA/TsONa co-doped PPy cathode was investigated in terms of scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FTIR), galvanostatic charge/discharge and cyclic voltammetry (CV). The results suggested that some oval-bud-like LA/TsONa co-doped PPy particles did form and tightly combine with the surface of Fe foil; furthermore, LA/TsONa co-doped PPy cathode also delivered higher electrochemical performances than TsONa mono-doped PPy cathode. For example, the initial specific discharge capacity was as high as about 124 mAh/g, and the reversible specific capacity still maintained at about 110 mAh/g even after 50 cycles, higher than those of TsONa mono-doped PPy cathode. The synergy effect of multi components of LA/TsONa co-doped PPy cathode should be responsible for high electrochemical performances.

  17. Unravelling the origin of irreversible capacity loss in NaNiO 2 for high voltage sodium ion batteries

    DOE PAGES

    Wang, Liguang; Wang, Jiajun; Zhang, Xiaoyi; ...

    2017-02-24

    Layered transition metal compounds have attracted much attention due to their high theoretical capacity and energy density for sodium ion batteries. However, this kind of material suffers from serious irreversible capacity decay during the charge and discharge process. Here, using synchrotron-based operando transmission X-ray microscopy and high-energy X-ray diffraction combined with electrochemical measurements, the visualization of the dissymmetric phase transformation and structure evolution mechanism of layered NaNiO 2 material during initial charge and discharge cycles are clarified. Phase transformation and deformation of NaNiO 2 during the voltage range of below 3.0 V and over 4.0 V are responsible for themore » irreversible capacity loss during the first cycling, which is also confirmed by the evolution of reaction kinetics behavior obtained by the galvanostatic intermittent titration technique. Lastly, these findings reveal the origin of the irreversibility of NaNiO 2 and offer valuable insight into the phase transformation mechanism, which will provide underlying guidance for further development of high-performance sodium ion batteries.« less

  18. Unravelling the origin of irreversible capacity loss in NaNiO 2 for high voltage sodium ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Liguang; Wang, Jiajun; Zhang, Xiaoyi

    Layered transition metal compounds have attracted much attention due to their high theoretical capacity and energy density for sodium ion batteries. However, this kind of material suffers from serious irreversible capacity decay during the charge and discharge process. Here, using synchrotron-based operando transmission X-ray microscopy and high-energy X-ray diffraction combined with electrochemical measurements, the visualization of the dissymmetric phase transformation and structure evolution mechanism of layered NaNiO 2 material during initial charge and discharge cycles are clarified. Phase transformation and deformation of NaNiO 2 during the voltage range of below 3.0 V and over 4.0 V are responsible for themore » irreversible capacity loss during the first cycling, which is also confirmed by the evolution of reaction kinetics behavior obtained by the galvanostatic intermittent titration technique. Lastly, these findings reveal the origin of the irreversibility of NaNiO 2 and offer valuable insight into the phase transformation mechanism, which will provide underlying guidance for further development of high-performance sodium ion batteries.« less

  19. Unravelling the origin of irreversible capacity loss in NaNiO 2 for high voltage sodium ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Liguang; Wang, Jiajun; Zhang, Xiaoyi

    Layered transition metal compounds have attracted much attention due to their high theoretical capacity and energy density for sodium ion batteries. However, this kind of material suffers from serious irreversible capacity decay during the charge and discharge process. Here, using synchrotron-based operando transmission X-ray microscopy and high-energy X-ray diffraction combined with electrochemical measurements, the visualization of the dissymmetric phase transformation and structure evolution mechanism of layered NaNiO2 material during initial charge and discharge cycles are clarified. Phase transformation and deformation of NaNiO2 during the voltage range of below 3.0 V and over 4.0 V are responsible for the irreversible capacitymore » loss during the first cycling, which is also confirmed by the evolution of reaction kinetics behavior obtained by the galvanostatic intermittent titration technique. These findings reveal the origin of the irreversibility of NaNiO2 and offer valuable insight into the phase transformation mechanism, which will provide underlying guidance for further development of high-performance sodium ion batteries.« less

  20. Improvement in Total Joint Replacement Quality Metrics: Year One Versus Year Three of the Bundled Payments for Care Improvement Initiative.

    PubMed

    Dundon, John M; Bosco, Joseph; Slover, James; Yu, Stephen; Sayeed, Yousuf; Iorio, Richard

    2016-12-07

    In January 2013, a large, tertiary, urban academic medical center began participation in the Bundled Payments for Care Improvement (BPCI) initiative for total joint arthroplasty, a program implemented by the Centers for Medicare & Medicaid Services (CMS) in 2011. Medicare Severity-Diagnosis Related Groups (MS-DRGs) 469 and 470 were included. We participated in BPCI Model 2, by which an episode of care includes the inpatient and all post-acute care costs through 90 days following discharge. The goal for this initiative is to improve patient care and quality through a patient-centered approach with increased care coordination supported through payment innovation. Length of stay (LOS), readmissions, discharge disposition, and cost per episode of care were analyzed for year 3 compared with year 1 of the initiative. Multiple programs were implemented after the first year to improve performance metrics: a surgeon-directed preoperative risk-factor optimization program, enhanced care coordination and home services, a change in venous thromboembolic disease (VTED) prophylaxis to a risk-stratified protocol, infection-prevention measures, a continued emphasis on discharge to home rather than to an inpatient facility, and a quality-dependent gain-sharing program among surgeons. There were 721 Medicare primary total joint arthroplasty patients in year 1 and 785 in year 3; their data were compared. The average hospital LOS decreased from 3.58 to 2.96 days. The rate of discharge to an inpatient facility decreased from 44% to 28%. The 30-day all-cause readmission rate decreased from 7% to 5%; the 60-day all-cause readmission rate decreased from 11% to 6%; and the 90-day all-cause readmission rate decreased from 13% to 8%. The average 90-day cost per episode decreased by 20%. Mid-term results from the implementation of Medicare BPCI Model 2 for primary total joint arthroplasty demonstrated decreased LOS, decreased discharges to inpatient facilities, decreased readmissions, and decreased cost of the episode of care in year 3 compared with year 1, resulting in increased value to all stakeholders involved in this initiative and suggesting that continued improvement over initial gains is possible.

  1. Implications of arcing due to spacecraft charging on spacecraft EMI margins of immunity

    NASA Technical Reports Server (NTRS)

    Inouye, G. T.

    1981-01-01

    Arcing due to spacecraft charging on spacecraft EMI margins of immunity was determined. The configuration of the P78-2 spacecraft of the SCATHA program was analyzed. A brushfire arc discharge model was developed, and a technique for initiating discharges with a spark plug trigger was for data configuration. A set of best estimate arc discharge parameters was defined. The effects of spacecraft potentials in limiting the discharge current blowout component are included. Arc discharge source models were incorporated into a SEMCAP EMI coupling analysis code for the DSP spacecraft. It is shown that with no mission critical circuits will be affected.

  2. Formula Milk Supplementation on the Postnatal Ward: A Cross-Sectional Analytical Study

    PubMed Central

    Biggs, Kirsty V.; Hurrell, Katherine; Matthews, Eleanor

    2018-01-01

    Breastfeeding rates are low in the UK, where approximately one quarter of infants receive a breastmilk substitute (BMS) in the first week of life. We investigated the reasons for early BMS use in two large maternity units in the UK, in order to understand the reasons for the high rate of early BMS use in this setting. Data were collected through infant feeding records, as well as maternal and midwife surveys in 2016. During 2016, 28% of infants received a BMS supplement prior to discharge from the hospital maternity units with only 10% supplementation being clinically indicated. There was wide variation in BMS initiation rates between different midwives, which was associated with ward environment and midwife educational level. Specific management factors associated with non-clinically indicated initiation of BMS were the absence of skin-to-skin contact within an hour of delivery (p = 0.01), and no attendance at an antenatal breastfeeding discussion (p = 0.01). These findings suggest that risk of initiating a BMS during postnatal hospital stay is largely modifiable. Concordance with UNICEF Baby Friendly 10 steps, attention to specific features of the postnatal ward working environment, and the targeting of midwives and mothers with poor educational status may all lead to improved exclusive breastfeeding rates at hospital discharge. PMID:29757936

  3. Formula Milk Supplementation on the Postnatal Ward: A Cross-Sectional Analytical Study.

    PubMed

    Biggs, Kirsty V; Hurrell, Katherine; Matthews, Eleanor; Khaleva, Ekaterina; Munblit, Daniel; Boyle, Robert J

    2018-05-14

    Breastfeeding rates are low in the UK, where approximately one quarter of infants receive a breastmilk substitute (BMS) in the first week of life. We investigated the reasons for early BMS use in two large maternity units in the UK, in order to understand the reasons for the high rate of early BMS use in this setting. Data were collected through infant feeding records, as well as maternal and midwife surveys in 2016. During 2016, 28% of infants received a BMS supplement prior to discharge from the hospital maternity units with only 10% supplementation being clinically indicated. There was wide variation in BMS initiation rates between different midwives, which was associated with ward environment and midwife educational level. Specific management factors associated with non-clinically indicated initiation of BMS were the absence of skin-to-skin contact within an hour of delivery ( p = 0.01), and no attendance at an antenatal breastfeeding discussion ( p = 0.01). These findings suggest that risk of initiating a BMS during postnatal hospital stay is largely modifiable. Concordance with UNICEF Baby Friendly 10 steps, attention to specific features of the postnatal ward working environment, and the targeting of midwives and mothers with poor educational status may all lead to improved exclusive breastfeeding rates at hospital discharge.

  4. Insights into the dual-electrode characteristics of layered Na 0.5Ni 0.25Mn 0.75O 2 materials for sodium-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manikandan, Palanisamy; Kim, Hyunwoo; Heo, Seongwoo

    Sodium-ion batteries are now close to replacing lithium-ion batteries because they provide superior alternative energy storage solutions that are in great demand, particularly for large-scale applications. To that end, the present study is focused on the properties of a new type of dual-electrode material, Na 0.5Ni 0.25Mn 0.75O 2, synthesized using a mixed hydroxycarbonate route. Cyclic voltammetry confirms that redox couples, at high and low voltage ranges, are facilitated by the unique features and properties of this dual-electrode, through sodium ion deintercalation/intercalation into the layered Na 0.5Ni 0.25Mn 0.25O 2 material. This material provides superior performance for Na-ion batteries, asmore » evidenced by the fabricated sodium cell that yielded initial charge discharge capacities of 125/218 mAh g -1 in the voltage range of 1.5-4.4 V at 0.5 C. At a low voltage range (1.5-2.6 V), the anode cell delivered discharge charge capacities of 100/99 mAh g -1 with 99% capacity retention, which corresponds to highly reversible redox reaction of the Mn 4+/3+ reduction and the Mn 3+/4+ oxidation observed at 1.85 and 2.06 V, respectively. The symmetric Na-ion cell, fabricated using Na 0.5Ni 0.25Mn 0.25O 2, yielded initial charge discharge capacities of 196/187 μAh at 107 μA. Lastly, these results encourage the further development of new types of futuristic sodium-ion battery-based energy storage systems.« less

  5. Atomic layer deposition of Al2O3 on V2O5 xerogel film for enhanced lithium-ion intercalation stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Dawei; Liu, Yanyi; Candelaria, Stephanie L.

    V2O5 xerogel films were fabricated by casting V2O5 sols onto fluorine-doped tin oxide glass substrates at room temperature. Five, ten and twenty atomic layers of Al2O3 were grown onto as-fabricated films respectively. The bare film and Al2O3-deposited films all exhibited hydrous V2O5 phase only. Electrochemical impedance spectroscopy study revealed increased surface charge-transfer resistance of V2O5 films as more Al2O3 atomic layers were deposited. Lithium-ion intercalation tests at 600 mAg_1 showed that bare V2O5 xerogel film possessed high initial discharge capacity of 219 mAhg_1 but suffered from severe capacity degradation, i.e., having only 136 mAhg_1 after 50 cycles. After deposition ofmore » ten atomic layers of Al2O3, the initial discharge capacity was 195 mAhg_1 but increased over cycles before stabilizing; after 50 cycles, the discharge capacity was as high as 225 mAhg_1. The noticeably improved cyclic stability of Al2O3-deposited V2O5 xerogel film could be attributed to the improved surface chemistry and enhanced mechanical strength. During repeated lithium-ion intercalation/de-intercalation, atomic layers of Al2O3 which were coated onto V2O5 surface could prevent V2O5 electrode dissolution into electrolyte by reducing direct contact between active electrode and electrolyte while at the same time acting as binder to maintain good mechanical contact between nanoparticles inside the film. VC 2012 American Vacuum Society.« less

  6. The Roles of Chronic Disease Complexity, Health System Integration, and Care Management in Post-Discharge Healthcare Utilization in a Low-Income Population.

    PubMed

    Hewner, Sharon; Casucci, Sabrina; Castner, Jessica

    2016-08-01

    Economically disadvantaged individuals with chronic disease have high rates of in-patient (IP) readmission and emergency department (ED) utilization following initial hospitalization. The purpose of this study was to explore the relationships between chronic disease complexity, health system integration (admission to accountable care organization [ACO] hospital), availability of care management interventions (membership in managed care organization [MCO]), and 90-day post-discharge healthcare utilization. We used de-identified Medicaid claims data from two counties in western New York. The study population was 114,295 individuals who met inclusion criteria, of whom 7,179 had index hospital admissions in the first 9 months of 2013. Individuals were assigned to three disease complexity segments based on presence of 12 prevalent conditions. The 30-day inpatient (IP) readmission rates ranged from 6% in the non-chronic segment to 12% in the chronic disease complexity segment and 21% in the organ system failure complexity segment. Rehospitalization rates (both inpatient and emergency department [ED]) were lower for patients in MCOs and ACOs than for those in fee-for-service care. Complexity of chronic disease, initial hospitalization in a facility that was part of an ACO, MCO membership, female gender, and longer length of stay were associated with a significantly longer time to readmission in the first 90 days, that is, fewer readmissions. Our results add to evidence that high-value post-discharge utilization (fewer IP or ED rehospitalizations and early outpatient follow-up) require population-based transitional care strategies that improve continuity between settings and take into account the illness complexity of the Medicaid population. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Insights into the dual-electrode characteristics of layered Na 0.5Ni 0.25Mn 0.75O 2 materials for sodium-ion batteries

    DOE PAGES

    Manikandan, Palanisamy; Kim, Hyunwoo; Heo, Seongwoo; ...

    2017-03-09

    Sodium-ion batteries are now close to replacing lithium-ion batteries because they provide superior alternative energy storage solutions that are in great demand, particularly for large-scale applications. To that end, the present study is focused on the properties of a new type of dual-electrode material, Na 0.5Ni 0.25Mn 0.75O 2, synthesized using a mixed hydroxycarbonate route. Cyclic voltammetry confirms that redox couples, at high and low voltage ranges, are facilitated by the unique features and properties of this dual-electrode, through sodium ion deintercalation/intercalation into the layered Na 0.5Ni 0.25Mn 0.25O 2 material. This material provides superior performance for Na-ion batteries, asmore » evidenced by the fabricated sodium cell that yielded initial charge discharge capacities of 125/218 mAh g -1 in the voltage range of 1.5-4.4 V at 0.5 C. At a low voltage range (1.5-2.6 V), the anode cell delivered discharge charge capacities of 100/99 mAh g -1 with 99% capacity retention, which corresponds to highly reversible redox reaction of the Mn 4+/3+ reduction and the Mn 3+/4+ oxidation observed at 1.85 and 2.06 V, respectively. The symmetric Na-ion cell, fabricated using Na 0.5Ni 0.25Mn 0.25O 2, yielded initial charge discharge capacities of 196/187 μAh at 107 μA. Lastly, these results encourage the further development of new types of futuristic sodium-ion battery-based energy storage systems.« less

  8. Implementation and Initial Validation of a 100-Kilowatt Class Nested-Channel Hall Thruster

    NASA Technical Reports Server (NTRS)

    Hall, Scott J.; Florenz, Roland E.; Gallimore, Alec D.; Kamhawi, Hani; Brown, Daniel L.; Polk, James E.; Goebel, Dan; Hofer, Richard R.

    2014-01-01

    The X3 is a 100-kilowatt class nested-channel Hall thruster developed by the Plasmadynamics and Electric Propulsion Laboratory at the University of Michigan in collaboration with the Air Force Research Laboratory and NASA. The cathode, magnetic circuit, boron nitride channel rings, and anodes all required specific design considerations during thruster development, and thermal modeling was used to properly account for thermal growth in material selection and component design. A number of facility upgrades were required at the University of Michigan to facilitate operation of the X3. These upgrades included a re-worked propellant feed system, a completely redesigned power and telemetry break-out box, and numerous updates to thruster handling equipment. The X3 was tested on xenon propellant at two current densities, 37% and 73% of the nominal design value. It was operated to a maximum steady-state discharge power of 60.8 kilowatts. The tests presented here served as an initial validation of thruster operation. Thruster behavior was monitored with telemetry, photography and high-speed current probes. The photography showed a uniform plume throughout testing. At constant current density, reductions in mass flow rate of 18% and 26% were observed in the three-channel operating configuration as compared to the superposition of each channel running individually. The high-speed current probes showed that the thruster was stable at all operating points and that the channels influence each other when more than one is operating simultaneously. Additionally, the ratio of peak-to-peak AC-coupled discharge current oscillations to mean discharge current did not exceed 51% for any operating points reported here, and did not exceed 17% at the higher current density.

  9. Insights into the Dual-Electrode Characteristics of Layered Na0.5Ni0.25Mn0.75O2 Materials for Sodium-Ion Batteries.

    PubMed

    Palanisamy, Manikandan; Kim, Hyun Woo; Heo, Seongwoo; Lee, Eungje; Kim, Youngsik

    2017-03-29

    Sodium-ion batteries are now close to replacing lithium-ion batteries because they provide superior alternative energy storage solutions that are in great demand, particularly for large-scale applications. To that end, the present study is focused on the properties of a new type of dual-electrode material, Na 0.5 Ni 0.25 Mn 0.75 O 2 , synthesized using a mixed hydroxy-carbonate route. Cyclic voltammetry confirms that redox couples, at high and low voltage ranges, are facilitated by the unique features and properties of this dual-electrode, through sodium ion deintercalation/intercalation into the layered Na 0.5 Ni 0.25 Mn 0.75 O 2 material. This material provides superior performance for Na-ion batteries, as evidenced by the fabricated sodium cell that yielded initial charge-discharge capacities of 125/218 mAh g -1 in the voltage range of 1.5-4.4 V at 0.5 C. At a low voltage range (1.5-2.6 V), the anode cell delivered discharge-charge capacities of 100/99 mAh g -1 with 99% capacity retention, which corresponds to highly reversible redox reaction of the Mn 4+/3+ reduction and the Mn 3+/4+ oxidation observed at 1.85 and 2.06 V, respectively. The symmetric Na-ion cell, fabricated using Na 0.5 Ni 0.25 Mn 0.75 O 2 , yielded initial charge-discharge capacities of 196/187 μAh at 107 μA. These results encourage the further development of new types of futuristic sodium-ion-battery-based energy storage systems.

  10. [Acute complicated and uncomplicated pyelonephritis in the emergency department: process-of-care indicators and outcomes].

    PubMed

    Delgado Vicente, Miriam; Lecaroz Agara, Mª Concepción; Barrios Andrés, José Luis; Canut Blasco, Andrés

    2017-02-01

    To assess process-of-care indicators and outcomes in acute pyelonephritis (APN) in a general hospital emergency department, and compare them between uncomplicaed and complicated APN. Retrospective study of consecutive patients discharged with a diagnosis of APN. We studied health processof- care indicators (percentage admitted, avoidable hospitalization, appropriate initial antibiotic therapy, urine and blood cultures) and outcomes (hospital length of stay [LOS], discharge from the emergency department, revisits, mortality, yields of microbiological tests ordered). A total of 529 cases (59% of them complicated) were included. Patients with uncomplicated APN were significantly younger on average (mean, 39 years) than patients with complicated APN (56 years). Escherichia coli was the most common pathogen identified, although the percentage of E coli infection was lower in patients with complicated APN (78%) than in patients with uncomplicated APN (95%). The rates of admission and orders for urine and blood cultures were significantly higher and hospital LOS was longer in the group with complicated APN. Moreover, these patients had even longer stays if the initial antibiotic therapy was inappropriate. Significantly more patients with uncomplicated APN were discharged from the emergency department. Sixty-one percent of patients with uncomplicated APN were admitted; 9% of these cases were considered avoidable hospitalizations. Complicated APN is diagnosed more often in older patients, and E coli infection causes a smaller proportion of these cases. Hospital LOS is longer in complicated APN and more urine and blood cultures are ordered. Patients with uncomplicated APN are more often discharged from the emergency department, although the number of avoidable hospitalizations seems high based on the rate found in this study.

  11. Geophysical Tools for an Improved Hydrogeologic Conceptual Model of the Big Chino Sub-basin, Central Arizona

    NASA Astrophysics Data System (ADS)

    Macy, J. P.; Kennedy, J.

    2017-12-01

    Water users and managers who rely on the Verde River system and its aquifers for water supplies have an intrinsic interest in developing the best possible tools for assessing the effects of groundwater withdrawals. Past, present, and future groundwater withdrawals from the Big Chino sub-basin will affect groundwater levels in the Big Chino area and groundwater discharge at the headwaters of the Verde River, specifically at the Upper Verde Springs, which is believed to be a major discharge zone of groundwater from the sub-basin. The amount and timing of reduced discharge as base flow is a function of connections between hydrogeologic (aquifer) units, aquifer storage properties and transmissivity, and proximity of withdrawal locations to discharge areas. To better define the aquifer units and aquifer storage properties, the United States Geological Survey, Cities of Prescott and Prescott Valley, and Salt River Project have initiated an ongoing geophysical study using controlled-source audio-frequency magnetotellurics (CSAMT) and repeat microgravity methods. CSAMT, a high-energy electromagnetic method sensitive to lithologic variations between rock and sediment types, is useful for defining aquifers at depths of up to 600 meters. Visual display of CSAMT profiles using Google Earth is useful for understanding and visualizing the relation between geophysics and Big Chino Sub-basin hydrogeology. Initial results from repeat microgravity surveys, which measure changes in subsurface mass (and therefore aquifer storage) over time, reveal spatial variation in the relation between aquifer storage changes and groundwater level changes. This variation reflects different confining conditions and multiple aquifer systems in different parts of the aquifer. Information about confining conditions and multiple aquifers could improve numerical groundwater models and predictions of future groundwater-level and base-flow depletion.

  12. Lithium-antimony-lead liquid metal battery for grid-level energy storage

    NASA Astrophysics Data System (ADS)

    Wang, Kangli; Jiang, Kai; Chung, Brice; Ouchi, Takanari; Burke, Paul J.; Boysen, Dane A.; Bradwell, David J.; Kim, Hojong; Muecke, Ulrich; Sadoway, Donald R.

    2014-10-01

    The ability to store energy on the electric grid would greatly improve its efficiency and reliability while enabling the integration of intermittent renewable energy technologies (such as wind and solar) into baseload supply. Batteries have long been considered strong candidate solutions owing to their small spatial footprint, mechanical simplicity and flexibility in siting. However, the barrier to widespread adoption of batteries is their high cost. Here we describe a lithium-antimony-lead liquid metal battery that potentially meets the performance specifications for stationary energy storage applications. This Li||Sb-Pb battery comprises a liquid lithium negative electrode, a molten salt electrolyte, and a liquid antimony-lead alloy positive electrode, which self-segregate by density into three distinct layers owing to the immiscibility of the contiguous salt and metal phases. The all-liquid construction confers the advantages of higher current density, longer cycle life and simpler manufacturing of large-scale storage systems (because no membranes or separators are involved) relative to those of conventional batteries. At charge-discharge current densities of 275 milliamperes per square centimetre, the cells cycled at 450 degrees Celsius with 98 per cent Coulombic efficiency and 73 per cent round-trip energy efficiency. To provide evidence of their high power capability, the cells were discharged and charged at current densities as high as 1,000 milliamperes per square centimetre. Measured capacity loss after operation for 1,800 hours (more than 450 charge-discharge cycles at 100 per cent depth of discharge) projects retention of over 85 per cent of initial capacity after ten years of daily cycling. Our results demonstrate that alloying a high-melting-point, high-voltage metal (antimony) with a low-melting-point, low-cost metal (lead) advantageously decreases the operating temperature while maintaining a high cell voltage. Apart from the fact that this finding puts us on a desirable cost trajectory, this approach may well be more broadly applicable to other battery chemistries.

  13. Lithium-antimony-lead liquid metal battery for grid-level energy storage.

    PubMed

    Wang, Kangli; Jiang, Kai; Chung, Brice; Ouchi, Takanari; Burke, Paul J; Boysen, Dane A; Bradwell, David J; Kim, Hojong; Muecke, Ulrich; Sadoway, Donald R

    2014-10-16

    The ability to store energy on the electric grid would greatly improve its efficiency and reliability while enabling the integration of intermittent renewable energy technologies (such as wind and solar) into baseload supply. Batteries have long been considered strong candidate solutions owing to their small spatial footprint, mechanical simplicity and flexibility in siting. However, the barrier to widespread adoption of batteries is their high cost. Here we describe a lithium-antimony-lead liquid metal battery that potentially meets the performance specifications for stationary energy storage applications. This Li||Sb-Pb battery comprises a liquid lithium negative electrode, a molten salt electrolyte, and a liquid antimony-lead alloy positive electrode, which self-segregate by density into three distinct layers owing to the immiscibility of the contiguous salt and metal phases. The all-liquid construction confers the advantages of higher current density, longer cycle life and simpler manufacturing of large-scale storage systems (because no membranes or separators are involved) relative to those of conventional batteries. At charge-discharge current densities of 275 milliamperes per square centimetre, the cells cycled at 450 degrees Celsius with 98 per cent Coulombic efficiency and 73 per cent round-trip energy efficiency. To provide evidence of their high power capability, the cells were discharged and charged at current densities as high as 1,000 milliamperes per square centimetre. Measured capacity loss after operation for 1,800 hours (more than 450 charge-discharge cycles at 100 per cent depth of discharge) projects retention of over 85 per cent of initial capacity after ten years of daily cycling. Our results demonstrate that alloying a high-melting-point, high-voltage metal (antimony) with a low-melting-point, low-cost metal (lead) advantageously decreases the operating temperature while maintaining a high cell voltage. Apart from the fact that this finding puts us on a desirable cost trajectory, this approach may well be more broadly applicable to other battery chemistries.

  14. Assessing various approaches for flash flood forecasting in the Yzeron periurban catchment (150 km2) south-east Lyon, France

    NASA Astrophysics Data System (ADS)

    Braud, Isabelle; Breil, Pascal; Javelle, Pierre; Pejakovic, Nikola; Guérin, Stéphane

    2017-04-01

    The Yzeron periurban catchment (150 km2) is prone to flash floods leading to overflow in the downstream part of the catchment. A prevention and management plan has been approved and the set-up of a flood forecasting system is planned. The present study presents a comparison of several solutions for flood forecasting in the catchment. It is based on an extensive data collection (rain gauges, radar/rain gauge reanalyses, discharge and water level data) from this experimental catchment. A set of rainfall-runoff events leading to floods (problematic and non-problematic floods) was extracted and formed the basis for the definition of a first forecasting method. It is based on data analysis and the identification of explaining factors amongst the following: rainfall amount, intensity, antecedent rainfall, initial discharge. Several statistical methods including Factorial Analysis of Mixed Data and Classification and Regression Tree were used for this purpose. They showed that several classes of problematic floods can be identified. The first one is related to wet conditions characterized with high initial discharge and antecedent rainfall. The second class is driven by rainfall amount, initial discharge and rainfall intensity. Thresholds of these variables can be identified to provide a first warning. The second forecasting method assessed in the study is the system that will be operational in France in 2017, based on the AIGA method (Javelle et al., 2016). For this purpose, 18-year discharge simulation using the hydrological model of the AIGA method, forced using radar/rain gauges reanalysis were available at 44 locations within the catchment. The dates for which quantiles of a given return period were overtopped were identified and compared with the list of problematic events. The AIGA method was found relevant in identifying the most problematic events, but the lead time needs further investigation in order to assess the usefulness for population warning. References: Pierre Javelle, Didier Organde, Julie Demargne, Clotilde Saint-Martin, Céline de Saint-Aubin, Léa Garandeau and Bruno Janet (2016). Setting up a French national flash flood warning system for ungauged catchments based on the AIGA method. E3S Web of Conferences 7, 18010 (2016), 3rd European Conference on Flood Risk Management (FLOODrisk 2016), http://dx.doi.org/10.1051/e3sconf/20160718010

  15. An Insurer's Care Transition Program Emphasizes Medication Reconciliation, Reduces Readmissions And Costs.

    PubMed

    Polinski, Jennifer M; Moore, Janice M; Kyrychenko, Pavlo; Gagnon, Michael; Matlin, Olga S; Fredell, Joshua W; Brennan, Troyen A; Shrank, William H

    2016-07-01

    Adverse drug events and the challenges of clarifying and adhering to complex medication regimens are central drivers of hospital readmissions. Medication reconciliation programs can reduce the incidence of adverse drug events after discharge, but evidence regarding the impact of medication reconciliation on readmission rates and health care costs is less clear. We studied an insurer-initiated care transition program based on medication reconciliation delivered by pharmacists via home visits and telephone and explored its effects on high-risk patients. We examined whether voluntary program participation was associated with improved medication use, reduced readmissions, and savings net of program costs. Program participants had a 50 percent reduced relative risk of readmission within thirty days of discharge and an absolute risk reduction of 11.1 percent. The program saved $2 for every $1 spent. These results represent real-world evidence that insurer-initiated, pharmacist-led care transition programs, focused on but not limited to medication reconciliation, have the potential to both improve clinical outcomes and reduce total costs of care. Project HOPE—The People-to-People Health Foundation, Inc.

  16. Cell voltage versus electrode potential range in aqueous supercapacitors

    PubMed Central

    Dai, Zengxin; Peng, Chuang; Chae, Jung Hoon; Ng, Kok Chiang; Chen, George Z.

    2015-01-01

    Supercapacitors with aqueous electrolytes and nanostructured composite electrodes are attractive because of their high charging-discharging speed, long cycle life, low environmental impact and wide commercial affordability. However, the energy capacity of aqueous supercapacitors is limited by the electrochemical window of water. In this paper, a recently reported engineering strategy is further developed and demonstrated to correlate the maximum charging voltage of a supercapacitor with the capacitive potential ranges and the capacitance ratio of the two electrodes. Beyond the maximum charging voltage, a supercapacitor may still operate, but at the expense of a reduced cycle life. In addition, it is shown that the supercapacitor performance is strongly affected by the initial and zero charge potentials of the electrodes. Further, the differences are highlighted and elaborated between freshly prepared, aged under open circuit conditions, and cycled electrodes of composites of conducting polymers and carbon nanotubes. The first voltammetric charging-discharging cycle has an electrode conditioning effect to change the electrodes from their initial potentials to the potential of zero voltage, and reduce the irreversibility. PMID:25897670

  17. Plasma puff initiation of high Coulomb transfer switches

    NASA Technical Reports Server (NTRS)

    Venable, D. D.; Choi, E. H.

    1990-01-01

    The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for the azimuthally uniform surface flashover which initiates plasma-puff under wide range of fill gas pressure of Ar, He and N2. The optimal fill gas pressure for the azimuthally uniform plasma-puff was about 120 mTorr and 450 Torr for He and N2, and between 120 mTorr and 5 Torr for Ar. The inverse pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. It was also shown that the azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff was also discussed in comparison with the hypocycloidal pinch plasma-puff triggering. The main discharge of inverse pinch switch with plasma-focus driven plasma-puff trigger is found to be more azimuthally uniform than that with hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr.

  18. The influence of Kr, CO2, and iso-C4H8 admixtures on the time of the formation of a stable flame front in mixtures of natural gas and isobutylene with oxygen and hydrogen with air under initiation with a spark discharge

    NASA Astrophysics Data System (ADS)

    Rubtsov, N. M.; Seplyarskii, B. S.; Chernysh, V. I.; Tsvetkov, G. I.

    2010-05-01

    High-speed color filming was used to study laminar spherical flame propagation at the initial stage in preliminarily mixed stoichiometric mixtures of natural gas and isobutylene with oxygen containing krypton and carbon dioxide and in hydrogen-air mixtures at atmospheric pressure in a bomb with a constant volume. Under experimental conditions ( T 0 = 298 K, p 0 = 100 torr, spark discharge energy E 0 = 0.91 J), the dilution of mixtures with Kr and CO2 increased the time of formation of a stable flame front by more than 10 times. The introduction of a small chemically active admixture (1.2% isobutylene) into a stoichiometric mixture of hydrogen and air sharply increased the time of formation of a stable flame front, which was evidence of an important role played by the chemical mechanism of the reaction in the formation of the combustion field.

  19. Phenomena of oscillations in atmospheric pressure direct current glow discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Fu-cheng; Yan, Wen; Wang, De-zhen

    2013-12-15

    Self-sustained oscillations in a dc glow discharge with a semiconductor layer at atmospheric pressure were investigated by means of a one-dimensional fluid model. It is found that the dc glow discharge initially becomes unstable in the subnormal glow region and gives rise to oscillations of plasma parameters. A variety of oscillations with one or more frequencies have been observed under different conditions. The discharge oscillates between the glow discharge mode and the Townsend discharge mode in the oscillations with large amplitude while operates in the subnormal glow discharge mode all the while in the oscillations with small amplitude. Fourier Transformmore » spectra of oscillations reveal the transition mechanism between different oscillations. The effects of semiconductor conductivity on the oscillation frequency of the dominant mode, gas voltage, as well as the discharge current have also been analyzed.« less

  20. Enteral Feeding With Human Milk Decreases Time to Discharge in Infants Following Gastroschisis Repair

    PubMed Central

    Gulack, Brian C.; Laughon, Matthew M.; Clark, Reese H.; Burgess, Terrance; Robinson, Sybil; Muhammad, Abdurrauf; Zhang, Angela; Davis, Adrienne; Morton, Robert; Chu, Vivian H.; Arnold, Christopher J.; Hornik, Christoph P.; Smith, P. Brian

    2015-01-01

    Objective We reviewed a multi-institutional database to assess the effect of enteral feeding with human milk on duration from initiation of feeds to discharge after gastroschisis repair. Study design Infants who had gastroschisis repair between 1997 and 2012 with data recorded in the Pediatrix Medical Group Clinical Data Warehouse were categorized into 4 groups based on the percentage of days they were fed human milk out of the number of days they were fed enterally. Cox proportional hazards regression modeling was performed to determine the adjusted effect of human milk on duration from initiation of feeds to discharge. Results Of 3082 infants, 659 (21%) were fed human milk on 0% of enteral feeding days, 766 (25%) on 1–50% of enteral feeding days, 725 (24%) on 51–99% of enteral feeding days, and 932 (30%) on 100% of enteral feeding days. Following adjustment, being fed human milk on 0% of enteral feeding days was associated with a significantly increased time to discharge compared with being fed human milk on 100% of enteral feeding days (HR for discharge per day: 0.46, 95% CI: 0.40–0.52). The same was found for infants fed human milk on 1–50% of enteral feeding days (HR: 0.37, 95% CI: 0.32–0.41) and for infants fed human milk on 51–99% of enteral feeding days (HR: 0.51, 95% CI: 0.46–0.57). Conclusion The use of human milk for enteral feeding of infants following repair of gastroschisis significantly reduces the time to discharge from initiation of feeds. PMID:26703875

  1. Enteral Feeding with Human Milk Decreases Time to Discharge in Infants following Gastroschisis Repair.

    PubMed

    Gulack, Brian C; Laughon, Matthew M; Clark, Reese H; Burgess, Terrance; Robinson, Sybil; Muhammad, Abdurrauf; Zhang, Angela; Davis, Adrienne; Morton, Robert; Chu, Vivian H; Arnold, Christopher J; Hornik, Christoph P; Smith, P Brian

    2016-03-01

    To assess the effect of enteral feeding with human milk on the time from initiation of feeds to discharge after gastroschisis repair through review of a multi-institutional database. Infants who underwent gastroschisis repair between 1997 and 2012 with data recorded in the Pediatrix Medical Group Clinical Data Warehouse were categorized into 4 groups based on the percentage of days fed human milk out of the number of days fed enterally. Cox proportional hazards regression modeling was performed to determine the adjusted effect of human milk on the time from initiation of feeds to discharge. Among 3082 infants, 659 (21%) were fed human milk on 0% of enteral feeding days, 766 (25%) were fed human milk on 1%-50% of enteral feeding days, 725 (24%) were fed human milk on 51%-99% of enteral feeding days, and 932 (30%) were fed human milk on 100% of enteral feeding days. Following adjustment, being fed human milk on 0% of enteral feeding days was associated with a significantly increased time to discharge compared with being fed human milk on 100% of enteral feeding days (hazard ratio [HR] for discharge per day, 0.46; 95% CI, 0.40-0.52). The same was found for infants fed human milk on 1%-50% of enteral feeding days (HR, 0.37; 95% CI, 0.32-0.41) and for infants fed human milk on 51%-99% of enteral feeding days (HR, 0.51; 95% CI, 0.46-0.57). The use of human milk for enteral feeding of infants following repair of gastroschisis significantly reduces the time to discharge from initiation of feeds. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Cambridge community Optometry Glaucoma Scheme.

    PubMed

    Keenan, Jonathan; Shahid, Humma; Bourne, Rupert R; White, Andrew J; Martin, Keith R

    2015-04-01

    With a higher life expectancy, there is an increased demand for hospital glaucoma services in the United Kingdom. The Cambridge community Optometry Glaucoma Scheme (COGS) was initiated in 2010, where new referrals for suspected glaucoma are evaluated by community optometrists with a special interest in glaucoma, with virtual electronic review and validation by a consultant ophthalmologist with special interest in glaucoma. 1733 patients were evaluated by this scheme between 2010 and 2013. Clinical assessment is performed by the optometrist at a remote site. Goldmann applanation tonometry, pachymetry, monoscopic colour optic disc photographs and automated Humphrey visual field testing are performed. A clinical decision is made as to whether a patient has glaucoma or is a suspect, and referred on or discharged as a false positive referral. The clinical findings, optic disc photographs and visual field test results are transmitted electronically for virtual review by a consultant ophthalmologist. The number of false positive referrals from initial referral into the scheme. Of the patients, 46.6% were discharged at assessment and a further 5.7% were discharged following virtual review. Of the patients initially discharged, 2.8% were recalled following virtual review. Following assessment at the hospital, a further 10.5% were discharged after a single visit. The COGS community-based glaucoma screening programme is a safe and effective way of evaluating glaucoma referrals in the community and reducing false-positive referrals for glaucoma into the hospital system. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  3. Retrospective evaluation of continental-scale streamflow nudging with WRF-Hydro National Water Model V1

    NASA Astrophysics Data System (ADS)

    McCreight, J. L.; Wu, Y.; Gochis, D.; Rafieeinasab, A.; Dugger, A. L.; Yu, W.; Cosgrove, B.; Cui, Z.; Oubeidillah, A.; Briar, D.

    2016-12-01

    The streamflow (discharge) data assimilation capability in version 1 of the National Water Model (NWM; a WRF-Hydro configuration) is applied and evaluated in a 5-year (2011-2015) retrospective study using NLDAS2 forcing data over CONUS. This talk will describe the NWM V1 operational nudging (continuous-time) streamflow data assimilation approach, its motivation, and its relationship to this retrospective evaluation. Results from this study will provide a an analysis-based (not forecast-based) benchmark for streamflow DA in the NWM. The goal of the assimilation is to reduce discharge bias and improve channel initial conditions for discharge forecasting (though forecasts are not considered here). The nudging method assimilates discharge observations at nearly 7,000 USGS gages (at frequency up to 1/15 minutes) to produce a (univariate) discharge reanalysis (i.e. this is the only variable affected by the assimilation). By withholding 14% nested gages throughout CONUS in a separate validation run, we evaluate the downstream impact of assimilation at upstream gages. Based on this sample, we estimate the skill of the streamflow reanalysis at ungaged locations and examine factors governing the skill of the assimilation. Comparison of assimilation and open-loop runs is presented. Performance of DA under both high and low flow regimes and selected flooding events is examined. Preliminary evaluation of nudging parameter sensitivity and its relationship to flow regime will be presented.

  4. Modeling the Influence of Early Skin-to-Skin Contact on Exclusive Breastfeeding in a Sample of Hispanic Immigrant Women.

    PubMed

    Linares, Ana M; Wambach, Karen; Rayens, Mary K; Wiggins, Amanda; Coleman, Elizabeth; Dignan, Mark B

    2017-10-01

    Using data from a longitudinal study of breastfeeding in Hispanics, this study evaluated the influence of early skin-to-skin contact (SSC) on initiation and sustained exclusive breastfeeding (EBF) at 1 month postpartum. Two-thirds of the women in the sample participated in early SSC. At discharge, over half of the women were EBF; this proportion decreased to one-third at 1 month postpartum. Controlling for demographic and clinical variables in the model, participation in early SSC was associated with a greater than sevenfold increase in the odds of EBF at discharge (p = .005) but was not predictive of EBF at 1 month post-discharge (p = .7). Younger maternal age and increased prenatal infant feeding intention were associated with an increased likelihood of EBF across both timepoints. Promoting early SSC may help with initiation of EBF, while further breastfeeding support may be needed to maintain EBF following discharge for this vulnerable population.

  5. Simulation studies of vestibular macular afferent-discharge patterns using a new, quasi-3-D finite volume method

    NASA Technical Reports Server (NTRS)

    Ross, M. D.; Linton, S. W.; Parnas, B. R.

    2000-01-01

    A quasi-three-dimensional finite-volume numerical simulator was developed to study passive voltage spread in vestibular macular afferents. The method, borrowed from computational fluid dynamics, discretizes events transpiring in small volumes over time. The afferent simulated had three calyces with processes. The number of processes and synapses, and direction and timing of synapse activation, were varied. Simultaneous synapse activation resulted in shortest latency, while directional activation (proximal to distal and distal to proximal) yielded most regular discharges. Color-coded visualizations showed that the simulator discretized events and demonstrated that discharge produced a distal spread of voltage from the spike initiator into the ending. The simulations indicate that directional input, morphology, and timing of synapse activation can affect discharge properties, as must also distal spread of voltage from the spike initiator. The finite volume method has generality and can be applied to more complex neurons to explore discrete synaptic effects in four dimensions.

  6. WIC-based interventions to promote breastfeeding among African-American Women in Baltimore: effects on breastfeeding initiation and continuation.

    PubMed

    Caulfield, L E; Gross, S M; Bentley, M E; Bronner, Y; Kessler, L; Jensen, J; Weathers, B; Paige, D M

    1998-03-01

    We evaluated the single and combined effects of introducing a motivational video and peer counseling into four matched WIC clinics on breastfeeding initiation and continuation at 7-10 days among African-American WIC participants. Of the 242 women with complete data, 48% initiated breastfeeding, but only 31% were still breastfeeding at 7-10 days. Initiation was associated with cesarean delivery, infant feeding instruction, no artificial milk discharge pack, attending the peer counselor only-intervention site, and intention to breastfeed. Continuation was influenced by infant feeding instruction, no artificial milk discharge pack, and intention to breastfeed. Overall, trends toward a positive impact of the breastfeeding promotion activities were evident but weak, and largely gone by 7-10 days postpartum.

  7. Tracking the Chemical and Structural Evolution of the TiS2 Electrode in the Lithium-Ion Cell Using Operando X-ray Absorption Spectroscopy.

    PubMed

    Zhang, Liang; Sun, Dan; Kang, Jun; Wang, Hsiao-Tsu; Hsieh, Shang-Hsien; Pong, Way-Faung; Bechtel, Hans A; Feng, Jun; Wang, Lin-Wang; Cairns, Elton J; Guo, Jinghua

    2018-06-06

    As the lightest and cheapest transition metal dichalcogenide, TiS 2 possesses great potential as an electrode material for lithium batteries due to the advantages of high energy density storage capability, fast ion diffusion rate, and low volume expansion. Despite the extensive investigation of its electrochemical properties, the fundamental discharge-charge reaction mechanism of the TiS 2 electrode is still elusive. Here, by a combination of ex situ and operando X-ray absorption spectroscopy with density functional theory calculations, we have clearly elucidated the evolution of the structural and chemical properties of TiS 2 during the discharge-charge processes. The lithium intercalation reaction is highly reversible and both Ti and sulfur are involved in the redox reaction during the discharge and charge processes. In contrast, the conversion reaction of TiS 2 is partially reversible in the first cycle. However, Ti-O related compounds are developed during electrochemical cycling over extended cycles, which results in the decrease of the conversion reaction reversibility and the rapid capacity fading. In addition, the solid electrolyte interphase formed on the electrode surface is found to be highly dynamic in the initial cycles and then gradually becomes more stable upon further cycling. Such understanding is important for the future design and optimization of TiS 2 based electrodes for lithium batteries.

  8. Dielectric surface discharges: Effects of combined low-energy and high-energy incident electrons

    NASA Technical Reports Server (NTRS)

    Balmain, K. G.; Hirt, W.

    1981-01-01

    Dielectric surface discharges affected by the addition of high energy electrons at 5 pA/sq cm to a primary 20 keV, 10 nA/sq cm electron beam with the high energy broad spectrum particles coming from the beta decay of Strontium 90 are studied. Kapton exhibits significantly increased discharge strength, increased waiting time between discharges, and a decreased number of discharges per specimen before discharge cessation. Mylar exhibits similar but less pronounced effects, while Teflon is relatively unaffected. With Kapton and Mylar, the high energy electrons act in some way to delay the instant of discharge ignition so that more charge can be accumulated and hence released during discharge.

  9. Cycle life testing of lithium-ion batteries for small satellite LEO space missions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayer, S.T.; Feikert, J.H.; Kaschmitter, J.L.

    1993-08-16

    In 1990, Sony corporation announced their intention to manufacture a rechargeable lithium ion battery, based on the intercalation of lithium ions into a carbonaceous anode. The cells were first introduced for portable telephone use in June, 1991. (1) A 3.6V average cell voltage (4.1-2.75V range); (2) Excellent cycle life (1200 @ 100% DOD); (3) Good capacity retention (70% after 6 months); (4) Wide temperature range performance ({minus}20 to +60{degrees}C); (5) Excellent Discharge rate (82% capacity at 30 min. discharge rate); (6) Excellent Charge rate (100% Charge in <3 hrs); and (7) High energy density (264 W*hr/1 and 120 Whr/kg formore » ``D`` size cell. These specifications show significant promise for application of these batteries in low earth orbit (LEO) small satellites, particularly when compared to existing NiH{sub 2} and NiCd technology. The very high energy density and specific energy will reduce power system volume and weight. The wide temperature range enables simpler thermal design, particularly for new, small, high power satellites. The materials used in the lithium ion batteries are relatively inexpensive and benign, so that we expect costs to come down substantially in the future. The specified cycle life at 100% DOD is also 50% longer than most NiCds, so low DOD (depth of discharge) performance could be substantial. This study was undertaken to: (a) assess the feasibility for using lithium ion cells on small satellite LEO missions and (b) verify the claims of the manufacturer. This was accomplished by performing a detailed autopsy and various depth of discharge and rate tests on the cells. Of special interest was the cycle life performance of these cell at various depths of discharge DOD`s, to get an initial measure of the reduction in capacity fade with cycle conditions. Low DOD`s are used to extend the life of all batteries used in a space application.« less

  10. Improved electrochemical performance of Li1.2Mn0.54Ni0.13Co0.13O2 cathode material synthesized by citric acid assisted sol-gel method for lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Li, Shiyou; Liang, Youwei; Lei, Dan; Xie, Yingchun; Ai, Ling; Xie, Jing

    2018-03-01

    A citric acid assisted sol-gel method is employed for synthesizing Li1.2Mn0.54Ni0.13Co0.13O2 used as a cathode material in lithium-ion batteries. Powder X-ray diffraction (XRD) and scanning electron microscopy (SEM) characterizations prove that materials have a typical a-NaFeO2 structure with primary nano-sized particles. Electrochemical performances have been investigated by charge-discharge test and results show that the synthesized product exhibits excellent electrochemical performance with a high initial discharge capacity of 253.5 mAh g-1 at 0.1 C and a preferable capacity retention of 84.8% after 50 cycles.

  11. Fast Positive Breakdown, NBEs, and Lightning Initiation

    NASA Astrophysics Data System (ADS)

    Krehbiel, P. R.; Rison, W.; Stock, M.; Edens, H. E.; Shao, X. M.; Thomas, R. J.; Stanley, M. A.; Zhang, Y.

    2016-12-01

    High power narrrow bipolar events (NBEs) have been found to be produced by arelatively unknown type of discharge, called fast positive breakdown (Rison etal., 2016). The breakdown occurs with a wide range of strengths, both in terms of its broadband sferic and its VHF radiation, and is found to be theinitiating event of many and likely all lightning discharges inside storms. Itdoes not produce a conducting channel but instead appears to be produced by avolumetric system of repeated, cascading positive streamers in virgin air.That positive corona and streamers would be responsible for initiatinglightning was proposed in the 1960s by Loeb, Dawson and Winn. In the 1970sPhelps and Griffiths showed that the streamers would be self-intensifying,leading to negative breakdown being initiated back at their starting points.Petersen et al. (2008) described experimental results showing that thestreamers could be initiated by ice crystals at cold temperatures, and thephysical processes leading to the breakdown being fast has been reported inrecent modeling studies by Shi et al. (2016). In this paper we summarize the observational data in support of the abovefindings, and report on additional observations of NBEs and lightninginitiation currently being obtained at Kennedy Space Center, Florida. References: Rison W., P.R. Krehbiel M.G.Stock, H.E. Edens, X-M. Shao, R.J. Thomas,M.A. Stanley, Y. Zhang, Observations of narrow bipolar events revealhow lightning is initiated in thunderstorms, Nature Comms. 7, 2016.doi:10.1038/ncomms10721. Petersen, D., Bailey, M., Beasley, W. & Hallett, J. A brief review ofthe problem of lightning initiation and a hypothesis of initiallightning leader formation. J. Geophys. Res. 113, D17205 (2008). Shi, F., N. Liu, and H. K. Rassoul (2016), Properties of relativelylong streamers initiated from an isolated hydrometeor, J. Geophys.Res. Atmos., 121, 7284-7295, doi:10.1002/2015JD024580.

  12. Hollow cathode startup using a microplasma discharge

    NASA Technical Reports Server (NTRS)

    Aston, G.

    1981-01-01

    Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.

  13. Bottle-feeding histories of preterm infants.

    PubMed

    Pickler, R H; Mauck, A G; Geldmaker, B

    1997-01-01

    To describe the bottle-feeding histories of preterm infants and determine physical indices related to and predictive of bottle-feeding initiation and progression. Ex post facto. Academic medical center. A convenience sample of 40 preterm infants without concomitant cardiac, gastrointestinal, or cognitive impairment. Postconceptional age at first bottle-feeding, full bottle-feeding, and discharge. The morbidity rating, using the Neonatal Medical Index (NMI), was most strongly correlated with postconceptional age at first bottle-feeding (r = .34, p < .05), full bottle-feeding (r = .65, p < .01), and discharge (r = .55, p < .05). The morbidity rating also accounted for 12%, 42%, and 30% of the variance in postconceptional age at first bottle-feeding, full bottle-feeding, and discharge, respectively. The NMI may be a useful tool for predicting the initiation and progression of bottle-feeding in preterm infants.

  14. Lightning-Discharge Initiation as a Noise-Induced Kinetic Transition

    NASA Astrophysics Data System (ADS)

    Iudin, D. I.

    2017-10-01

    The electric fields observed in thunderclouds have the peak values one order of magnitude smaller than the electric strength of air. This fact renders the issue of the lightning-discharge initiation one of the most intriguing problems of thunderstorm electricity. In this work, the lightning initiation in a thundercloud is considered as a noise-induced kinetic transition. The stochastic electric field of the charged hydrometeors is the noise source. The considered kinetic transition has some features which distinguish it from other lightning-initiation mechanisms. First, the dynamic realization of this transition, which is due to interaction of the electron and ion components, is extended for a time significantly exceeding the spark-discharge development time. In this case, the fast attachment of electrons generated by supercritical bursts of the electric field of hydrometeors is balanced during long-term time intervals by the electron-release processes when the negative ions are destroyed. Second, an important role in the transition kinetics is played by the stochastic drift of electrons and ions caused by the small-scale fluctuations of the field of charged hydrometeors. From the formal mathematical viewpoint, this stochastic drift is indistinguishable from the scalar-impurity advection in a turbulent flow. In this work, it is shown that the efficiency of "advective mixing" is several orders of magnitude greater than that of the ordinary diffusion. Third, the considered transition leads to a sharp increase in the conductivity in the exponentially rare compact regions of space against the background of the vanishingly small variations in the average conductivity of the medium. In turn, the spots with increased conductivity are polarized in the mean field followed by the streamer initiation and discharge contraction.

  15. Detonator Performance Characterization Using Multi-Frame Laser Schlieren Imaging

    NASA Astrophysics Data System (ADS)

    Clarke, S. A.; Landon, C. D.; Murphy, M. J.; Martinez, M. E.; Mason, T. A.; Thomas, K. A.

    2009-12-01

    Several experiments that are part of a phased plan to understand the evolution of detonation in a detonator from initiation shock through run to detonation to full detonation to transition to booster and booster detonation will be presented. High speed laser schlieren movies have been used to study several explosive initiation events, such as exploding bridgewires (EBW), exploding foil initiators (EFI) (or slappers), direct optical initiation (DOI), and electrostatic discharge (ESD). Additionally, a series of tests have been performed on "cut-back" detonators with varying initial pressing (IP) heights. We have also used this diagnostic to visualize a range of EBW, EFI, and DOI full-up detonators. Future applications to other explosive events such as boosters and IHE booster evaluation will be discussed. The EPIC hydrodynamic code has been used to analyze the shock fronts from the schlieren images to reverse calculate likely boundary or initial conditions to determine the temporal-spatial pressure profile across the output face of the detonator. LA-UR-05099

  16. Using Schlieren Visualization to Track Detonator Performance

    NASA Astrophysics Data System (ADS)

    Clarke, Steven; Thomas, Keith; Martinez, Michael; Akinci, Adrian; Murphy, Michael; Adrian, Ronald

    2007-06-01

    Several experiments that are part of a phased plan to understand the evolution of detonation in a detonator from initiation shock through run to detonation to full detonation to transition to booster and booster detonation will be presented. High Speed Laser Schlieren Movies have been used to study several explosive initiation events, such as exploding bridgewires (EBW), Exploding Foil Initiators (EFI) (or slappers), Direct Optical Initiation (DOI), and ElectroStatic Discharge (ESD). Additionally, a series of tests have been performed on ``cut-back'' detonators with varying initial pressing (IP) heights. We have also used this diagnostic to visualize a range of EBW, EFI, and DOI full-up detonators. Future applications to other explosive events such as boosters and IHE booster evaluation will be discussed. EPIC Hydrodynamic code has been used to analyze the shock fronts from the Schlieren images to reverse calculate likely boundary or initial conditions to determine the temporal-spatial pressure profile across the output face of the detonator. LA-UR-07-1229

  17. Wire chamber radiation detector with discharge control

    DOEpatents

    Perez-Mendez, Victor; Mulera, Terrence A.

    1984-01-01

    A wire chamber radiation detector (11) has spaced apart parallel electrodes (16) and grids (17, 18, 19) defining an ignition region (21) in which charged particles (12) or other ionizing radiations initiate brief localized avalanche discharges (93) and defining an adjacent memory region (22) in which sustained glow discharges (94) are initiated by the primary discharges (93). Conductors (29, 32) of the grids (18, 19) at each side of the memory section (22) extend in orthogonal directions enabling readout of the X-Y coordinates of locations at which charged particles (12) were detected by sequentially transmitting pulses to the conductors (29) of one grid (18) while detecting transmissions of the pulses to the orthogonal conductors (36) of the other grid (19) through glow discharges (94). One of the grids (19) bounding the memory region (22) is defined by an array of conductive elements (32) each of which is connected to the associated readout conductor (36) through a separate resistance (37). The wire chamber (11) avoids ambiguities and imprecisions in the readout of coordinates when large numbers of simultaneous or near simultaneous charged particles (12) have been detected. Down time between detection periods and the generation of radio frequency noise are also reduced.

  18. Benthic Faunal Colonization of an Offshore Borrow Pit in Southeastern Florida. Dredging Operations Technical Support Program

    DTIC Science & Technology

    1988-10-01

    180 and 30* C, while water salinities vary between 33 and 37 ppt, depending primarily on seasonal rainfall patterns and discharge through local inlets...strategists are characteristically small-bodied, short-lived, and have high fecundity, efficient dispersal mechanisms , and rapid growth rates. Species... mechanisms , and slow growth rates. Recolonization of a disturbed area is thus generally initiated by r-strategists. Theoretically, r-selected species

  19. Large scale Tesla coil guided discharges initiated by femtosecond laser filamentation in air

    NASA Astrophysics Data System (ADS)

    Arantchouk, L.; Point, G.; Brelet, Y.; Prade, B.; Carbonnel, J.; André, Y.-B.; Mysyrowicz, A.; Houard, A.

    2014-07-01

    The guiding of meter scale electric discharges produced in air by a Tesla coil is realized in laboratory using a focused terawatt laser pulse undergoing filamentation. The influence of the focus position, the laser arrival time, or the gap length is studied to determine the best conditions for efficient laser guiding. Discharge parameters such as delay, jitter, and resistance are characterized. An increase of the discharge length by a factor 5 has been achieved with the laser filaments, corresponding to a mean breakdown field of 2 kV/cm for a 1.8 m gap length. Consecutive guided discharges at a repetition rate of 10 Hz are also reported.

  20. NASCAP modelling of environmental-charging-induced discharges in satellites

    NASA Technical Reports Server (NTRS)

    Stevens, N. J.; Roche, J. C.

    1979-01-01

    The charging and discharging characteristics of a typical geosynchronous satellite experiencing time-varying geomagnetic substorms, in sunlight, were studied utilizing the NASA Charging Analyzer Program (NASCAP). An electric field criteria of 150,000 volts/cm to initiate discharges and transfer of 67 percent of the stored charge was used based on ground test results. The substorm characteristics were arbitrarily chosen to evaluate effects of electron temperature and particle density (which is equivalent to current density). It was found that while there is a minimum electron temperature for discharges to occur, the rate of discharges is dependent on particle density and duration times of the encounter. Hence, it is important to define the temporal variations in the substorm environments.

  1. CORMIX: AN EXPERT SYSTEM FOR MIXING ZONE ANALYSIS

    EPA Science Inventory

    United States water quality policy includes the concept of a fixing zone, a limited area where initial dilution of a discharge occurs. urrent practice in mixing zone analysis is plagued by a number of problems--mixing zone definitions vary widely, there is a diversity of discharg...

  2. 76 FR 24874 - Initiation of Scoping for an Environmental Assessment (EA)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ...) General Permit for Discharges from Construction Activities. The EA will evaluate the potential environmental impacts from the discharge of pollutants associated with stormwater runoff from construction... days of the date of the publication of the Proposed Construction General Permit in the Federal Register...

  3. Recruitment and rate coding organisation for soleus motor units across entire range of voluntary isometric plantar flexions.

    PubMed

    Oya, Tomomichi; Riek, Stephan; Cresswell, Andrew G

    2009-10-01

    Unlike upper limb muscles, it remains undocumented as to how motor units in the soleus muscle are organised in terms of recruitment range and discharge rates with respect to their recruitment and de-recruitment thresholds. The possible influence of neuromodulation, such as persistent inward currents (PICs) on lower limb motor unit recruitment and discharge rates has also yet to be reported. To address these issues, electromyographic (EMG) activities from the soleus muscle were recorded using selective branched-wire intramuscular electrodes during ramp-and-hold contractions with intensities up to maximal voluntary contraction (MVC). The multiple single motor unit activities were then derived using a decomposition technique. The onset-offset hysteresis of motor unit discharge, i.e. a difference between recruitment and de-recruitment thresholds, as well as PIC magnitude calculated by a paired motor unit analysis were used to examine the neuromodulatory effects on discharge behaviours, such as minimum firing rate, peak firing rate and degree of increase in firing rate. Forty-two clearly identified motor units from five subjects revealed that soleus motor units are recruited progressively from rest to contraction strengths close to 95% of MVC, with low-threshold motor units discharging action potentials slower at their recruitment and with a lower peak rate than later recruited high-threshold units. This observation is in contrast to the 'onion skin phenomenon' often reported for the upper limb muscles. Based on positive correlations of the peak discharge rates, initial rates and recruitment order of the units with the magnitude of the onset-offset hysteresis and not PIC contribution, we conclude that discharge behaviours among motor units appear to be related to a variation in an intrinsic property other than PICs.

  4. BK potassium channels facilitate high-frequency firing and cause early spike frequency adaptation in rat CA1 hippocampal pyramidal cells

    PubMed Central

    Gu, Ning; Vervaeke, Koen; Storm, Johan F

    2007-01-01

    Neuronal potassium (K+) channels are usually regarded as largely inhibitory, i.e. reducing excitability. Here we show that BK-type calcium-activated K+ channels enhance high-frequency firing and cause early spike frequency adaptation in neurons. By combining slice electrophysiology and computational modelling, we investigated functions of BK channels in regulation of high-frequency firing in rat CA1 pyramidal cells. Blockade of BK channels by iberiotoxin (IbTX) selectively reduced the initial discharge frequency in response to strong depolarizing current injections, thus reducing the early spike frequency adaptation. IbTX also blocked the fast afterhyperpolarization (fAHP), slowed spike rise and decay, and elevated the spike threshold. Simulations with a computational model of a CA1 pyramidal cell confirmed that the BK channel-mediated rapid spike repolarization and fAHP limits activation of slower K+ channels (in particular the delayed rectifier potassium current (IDR)) and Na+ channel inactivation, whereas M-, sAHP- or SK-channels seem not to be important for the early facilitating effect. Since the BK current rapidly inactivates, its facilitating effect diminishes during the initial discharge, thus producing early spike frequency adaptation by an unconventional mechanism. This mechanism is highly frequency dependent. Thus, IbTX had virtually no effect at spike frequencies < 40 Hz. Furthermore, extracellular field recordings demonstrated (and model simulations supported) that BK channels contribute importantly to high-frequency burst firing in response to excitatory synaptic input to distal dendrites. These results strongly support the idea that BK channels play an important role for early high-frequency, rapidly adapting firing in hippocampal pyramidal neurons, thus promoting the type of bursting that is characteristic of these cells in vivo, during behaviour. PMID:17303637

  5. Initiation of a lightning search using the lightning and airglow camera onboard the Venus orbiter Akatsuki

    NASA Astrophysics Data System (ADS)

    Takahashi, Yukihiro; Sato, Mitsuteru; Imai, Masataka; Lorenz, Ralph; Yair, Yoav; Aplin, Karen; Fischer, Georg; Nakamura, Masato; Ishii, Nobuaki; Abe, Takumi; Satoh, Takehiko; Imamura, Takeshi; Hirose, Chikako; Suzuki, Makoto; Hashimoto, George L.; Hirata, Naru; Yamazaki, Atsushi; Sato, Takao M.; Yamada, Manabu; Murakami, Shin-ya; Yamamoto, Yukio; Fukuhara, Tetsuya; Ogohara, Kazunori; Ando, Hiroki; Sugiyama, Ko-ichiro; Kashimura, Hiroki; Ohtsuki, Shoko

    2018-05-01

    The existence of lightning discharges in the Venus atmosphere has been controversial for more than 30 years, with many positive and negative reports published. The lightning and airglow camera (LAC) onboard the Venus orbiter, Akatsuki, was designed to observe the light curve of possible flashes at a sufficiently high sampling rate to discriminate lightning from other sources and can thereby perform a more definitive search for optical emissions. Akatsuki arrived at Venus during December 2016, 5 years following its launch. The initial operations of LAC through November 2016 have included a progressive increase in the high voltage applied to the avalanche photodiode detector. LAC began lightning survey observations in December 2016. It was confirmed that the operational high voltage was achieved and that the triggering system functions correctly. LAC lightning search observations are planned to continue for several years.

  6. Framework and components for effective discharge planning system: a delphi methodology

    PubMed Central

    2012-01-01

    Background To reduce avoidable hospital readmissions, effective discharge planning and appropriate post discharge support care are key requirements. This study is a 3-staged process to develop, pretest and pilot a framework for an effective discharge planning system in Hong Kong. This paper reports on the methodology of Delphi approach and findings of the second stage on pre-testing the framework developed so as to validate and attest to its applicability and practicability in which consensus was sought on the key components of discharge planning. Methods Delphi methodology was adopted to engage a group of experienced healthcare professionals to rate and discuss the framework and components of an effective discharge planning. The framework was consisted 36 statements under 5 major themes: initial screening, discharge planning process, coordination of discharge, implementation of discharge, and post discharge follow-up. Each statement was rated independently based on 3 aspects including clarity, validity and applicability on a 5-point Likert-scale. Statement with 75% or above of participants scoring 4–5 on all 3 aspects would be included in the discharge planning framework. For those statements not reaching 75% of consensus in any one of the aspect, it would be revised or discarded following the group discussion, and be re-rated in another round. Results A total of 24 participants participated in the consensus-building process. In round one rating, consensus was achieved in 25 out of 36 statements. Among those 11 statements not reaching consensus, the major concern was related to the “applicability” of the statements. The participants expressed a lack of manpower, skills and time in particular during weekends and long holidays in carrying out assessment and care plans within 24 h after admission. There were also timeliness and availability issue in providing transportation and necessary equipment to the patients. To make the statements more applicable, the wordings of some of the statements were revised to provide greater flexibility. Due to the lack of a statement in clarifying the role of the members of the healthcare professional team, one additional statement on the role and responsibility of the multidisciplinary team members was added. The first theme on “initial screening” was further revised to “initial screening and assessment” to better reflect the first stage of discharge planning process. After two rounds of rating process, all the 36 statements and the newly added statement reached consensus Conclusions A structured, systematic and coordinated system of hospital discharge system is required to facilitate the discharge process to ensure a smooth patient transition from the hospital to the community and improve patient health outcome in both clinical and social aspect. The findings of this paper provide a reference framework helping policymakers and hospital managers to facilitate the development of a coherent and systematized discharge planning process. Adopting a Delphi approach also demonstrates the values of the method as a pre-test (before the clinical run) of the components and requirements of a discharge planning system taking into account of the local context and system constraints, which would lead to improvements to its applicability and practicability. To confirm the applicability and practicability of this consensus framework for discharge planning system, the third stage of process of development of the discharge planning framework is to apply and pilot the framework in a hospital setting to evaluate its feasibility, applicability and impact in hospital including satisfaction from both the perspectives of staff and patients. PMID:23151173

  7. Adult emergency department patients with sickle cell pain crisis: a learning collaborative model to improve analgesic management.

    PubMed

    Tanabe, Paula; Artz, Nicole; Mark Courtney, D; Martinovich, Zoran; Weiss, Kevin B; Zvirbulis, Elena; Hafner, John W

    2010-04-01

    The objectives were to report the baseline (prior to quality improvement interventions) patient and visit characteristics and analgesic management practices for each site participating in an emergency department (ED) sickle cell learning collaborative. A prospective, multisite longitudinal cohort study in the context of a learning-collaborative model was performed in three midwestern EDs. Each site formed a multidisciplinary team charged with improving analgesic management for patients with sickle cell disease (SCD). Each team developed a nurse-initiated analgesic protocol for SCD patients (implemented after a baseline data collection period of 3.5 months at one site and 10 months at the other two sites). All sites prospectively enrolled adults with an acute pain crisis and SCD. All medical records for patients meeting study criteria were reviewed. Demographic, health services, and analgesic management data were abstracted, including ED visit frequency data, ED disposition, arrival and discharge pain score, and name and route of initial analgesic administered. Ten interviews per quarter per site were conducted with patients within 14 days of their ED discharge, and subjects were queried about the highest level of pain acceptable at discharge. The primary outcome variable was the time to initial analgesic administration. Variable data were described as means and standard deviations (SDs) or medians and interquartile ranges (IQR) for nonnormal data. A total of 155 patients met study criteria (median age = 32 years, IQR = 24-40 years) with a total of 701 ED visits. Eighty-six interviews were conducted. Most patients (71.6%) had between one and three visits to the ED during the study period. However, after removing Site 3 from the analysis because of the short data enrollment period (3.5 months), which influenced the mean number of visits for the entire cohort, 52% of patients had between one and three ED visits over 10 months, 21% had four to nine visits, and 27% had between 10 and 67 visits. Fifty-nine percent of patients were discharged home. The median time to initial analgesic for the cohort was 74 minutes (IQR = 48-135 minutes). Differences between choice of analgesic agent and route selected were evident between sites. For the cohort, 680 initial analgesic doses were given (morphine sulfate, 42%; hydromorphone, 46%; meperidine, 4%; morphine sulfate and ibuprofen or ketorolac, 7%) using the following routes: oral (2%), intravenous (67%), subcutaneous (3%), and intramuscular (28%). Patients reported a significantly lower targeted discharge pain score (mean +/- SD = 4.19 +/- 1.18) compared to the actual documented discharge pain score within 45 minutes of discharge (mean +/- SD = 5.77 +/- 2.45; mean difference = 1.58, 95% confidence interval = .723 to 2.44, n = 43). While half of the patients had one to three ED visits during the study period, many patients had more frequent visits. Delays to receiving an initial analgesic were common, and post-ED interviews reveal that sickle cell pain patients are discharged from the ED with higher pain scores than what they perceive as desirable.

  8. Final Report: Levitated Dipole Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kesner, Jay; Mauel, Michael

    2013-03-10

    Since the very first experiments with the LDX, research progress was rapid and significant. Initial experiments were conducted with the high-field superconducting coil suspended by three thin rods. These experiments produced long-pulse, quasi-steady-state microwave discharges, lasting more than 10 s, having peak beta values of 20% [Garnier et al., Physics of Plasmas, 13 (2006) 056111]. High- beta, near steady-state discharges have been maintained in LDX for more than 20 seconds, and this capability made LDX the longest pulse fusion confinement experiment operating in the U.S. fusion program. A significant measure of progress in the LDX research program was the routinemore » investigation of plasma confinement with a magnetically-levitated dipole and the resulting observations of confinement improvement. In both supported and levitated configurations, detailed measurements were made of discharge evolution, plasma dynamics and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. High-temperature plasma was created by multi frequency electron cyclotron resonance heating at 2.45 GHz, 6.4 GHz, 10.5 GHz and 28 GHz allowing control of heating profiles. Depending upon neutral fueling rates, the LDX discharges contain a fraction of energetic electrons, with mean energies above 50 keV. Depending on whether or not the superconducting dipole was levitated or supported, the peak thermal electron temperature was estimated to exceed 500 eV and peak densities to approach 1e18 m -3. We have found that levitation causes a strong inwards density pinch [Boxer et al., Nature Physics, 6 (2010) 207] and we have observed the central plasma density increase dramatically indicating a significant improvement in the confinement of a thermal plasma species.« less

  9. NOx formation in apokamp-type atmospheric pressure plasma jets in air initiated by a pulse-repetitive discharge

    NASA Astrophysics Data System (ADS)

    Sosnin, Eduard A.; Didenko, Maria V.; Panarin, Victor A.; Skakun, Victor S.; Tarasenko, Victor F.; Liu, Dongping P.; Song, Ying

    2018-04-01

    The decomposition products of atmospheric pressure plasma of repetitive pulsed discharge in apokamp and corona modes were determined by optical and chemical methods. It is shown, that the decomposition products contain mainly nitrogen oxides NOx. A brief review of the plasma- and thermochemical reactions in the pulsed discharges was made. The review and experimental data allow us to explain the reactive oxygen species formation mechanisms in a potential discharge channel with apokamp. The possible applications of this plasma source for treatment of seeds of agricultural crops are discussed.

  10. Experimental research on medium-frequency discharge cleaning in the HT-6M tokamak

    NASA Astrophysics Data System (ADS)

    Li, Chengfu; Guo, Wenkang; Gu, Xuemao; Luo, Nanchang; Hu, Wanfen; Cheng, Shanhua; Qian, Chao

    1989-04-01

    Surface cleaning experiments of the wall of HT-6M tokamak chamber by medium-frequency discharge (MFD) in hydrogen has been monitored and analysed by. QMS and AES. After 300 min discharge, the signals with mass number 12 and 18 were 100 times less than their initial values. The concentration of C and O on the wall surface decreased to 26% and 5.8%, respectively. The cleaning efficiency of MFD has been compared with that of DC glow discharge. The results showed that the former was superior to the later in ability of water release.

  11. INTENSE ENERGETIC GAS DISCHARGE

    DOEpatents

    Luce, J.S.

    1960-03-01

    A method and apparatus for initiating and sustaining an energetic gas arc discharge are described. A hollow cathode and a hollow anode are provided. By regulating the rate of gas flow into the interior of the cathode, the arc discharge is caused to run from the inner surface of the cathode with the result that adequate space-charge neutralization is provided inside the cathode but not in the main arc volume. Thus, the gas fed to the cathode is substantially completely ionized before it leaves the cathode, with the result that an energetic arc discharge can be maintained at lower operating pressures.

  12. Purification of inkjet ink from water using liquid phase, electric discharge polymerization and cellulosic membrane filtration.

    PubMed

    Jordan, Alexander T; Hsieh, Jeffery S; Lee, Daniel T

    2013-01-01

    A method to separate inkjet ink from water was developed using a liquid phase, electric discharge process. The liquid phase, electric discharge process with filtration or sedimentation was shown to remove 97% of inkjet ink from solutions containing between 0.1-0.8 g/L and was consistent over a range of treatment conditions. Additionally, particle size analysis of treated allyl alcohol and treated propanol confirmed the electric discharge treatment has a polymerization mechanism, and small molecule analysis of treated methanol using gas chromatography and mass spectroscopy confirmed the mechanism was free radical initiated polymerization.

  13. Formation of a spark discharge in an inhomogeneous electric field with current limitation by a large ballast Resistance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baldanov, B. B., E-mail: baibat@mail.ru

    2016-01-15

    Results of studies of a spark discharge initiated in argon in a point–plane electrode gap with limitation of the discharge current by a large ballast resistance are presented. It is shown that the current flowing through the plasma channel of such a low-current spark has the form of periodic pulses. It is experimentally demonstrated that, when a low-current spark transforms into a constricted glow discharge, current pulses disappear, the spatial structure of the cathode glow changes abruptly, and a brightly glowing positive plasma column forms in the gap.

  14. Dielectric surface discharges - Effects of combined low-energy and high-energy incident electrons

    NASA Technical Reports Server (NTRS)

    Balmain, K. G.; Hirt, W.

    1983-01-01

    Dielectric surface discharges affected by the addition of high energy electrons at 5 pA/sq cm to a primary 20 keV, 10 nA/sq cm electron beam with the high energy broad spectrum particles coming from the beta decay of Strontium 90 are studied. Kapton exhibits significantly increased discharge strength, increased waiting time between discharges, and a decreased number of discharges per specimen before discharge cessation. Mylar exhibits similar but less pronounced effects, while Teflon is relatively unaffected. With Kapton and Mylar, the high energy electrons act in some way to delay the instant of discharge ignition so that more charge can be accumulated and hence released during discharge. Previously announced in STAR as N82-14222

  15. Time evolution of nanosecond runaway discharges in air and helium at atmospheric pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yatom, S.; Vekselman, V.; Krasik, Ya. E.

    2012-12-15

    Time- and space-resolved fast framing photography was employed to study the discharge initiated by runaway electrons in air and He gas at atmospheric pressure. Whereas in the both cases, the discharge occurs in a nanosecond time scale and its front propagates with a similar velocity along the cathode-anode gap, the later stages of the discharge differ significantly. In air, the main discharge channels develop and remain in the locations with the strongest field enhancement. In He gas, the first, diode 'gap bridging' stage, is similar to that obtained in air; however, the development of the discharge that follows is dictatedmore » by an explosive electron emission from micro-protrusions on the edge of the cathode. These results allow us to draw conclusions regarding the different conductivity of the plasma produced in He and air discharges.« less

  16. Generator and Setup for Emulating Exposures of Biological Samples to Lightning Strokes.

    PubMed

    Rebersek, Matej; Marjanovic, Igor; Begus, Samo; Pillet, Flavien; Rols, Marie-Pierre; Miklavcic, Damijan; Kotnik, Tadej

    2015-10-01

    We aimed to develop a system for controlled exposure of biological samples to conditions they experience when lightning strikes their habitats. We based the generator on a capacitor charged via a bridge rectifier and a dc-dc converter, and discharged via a relay, delivering arcs similar to natural lightning strokes in electric current waveform and similarly accompanied by acoustic shock waves. We coupled the generator to our exposure chamber described previously, measured electrical and acoustic properties of arc discharges delivered, and assessed their ability to inactivate bacterial spores. Submicrosecond discharges descended vertically from the conical emitting electrode across the air gap, entering the sample centrally and dissipating radially toward the ring-shaped receiving electrode. In contrast, longer discharges tended to short-circuit the electrodes. Recording at 341 000 FPS with Vision Research Phantom v2010 camera revealed that initial arc descent was still vertical, but became accompanied by arcs leaning increasingly sideways; after 8-12 μs, as the first of these arcs formed direct contact with the receiving electrode, it evolved into a channel of plasmified air and short-circuited the electrodes. We eliminated this artefact by incorporating an insulating cylinder concentrically between the electrodes, precluding short-circuiting between them. While bacterial spores are highly resistant to electric pulses delivered through direct contact, we showed that with arc discharges accompanied by an acoustic shock wave, spore inactivation is readily obtained. The presented system allows scientific investigation of effects of arc discharges on biological samples. This system will allow realistic experimental studies of lightning-triggered horizontal gene transfer and assessment of its role in evolution.

  17. Enhancement of discharge performance of Li/CF x cell by thermal treatment of CF x cathode material

    NASA Astrophysics Data System (ADS)

    Zhang, Sheng S.; Foster, Donald; Read, Jeffrey

    In this work we demonstrate that the thermal treatment of CF x cathode material just below the decomposition temperature can enhance discharge performance of Li/CF x cells. The performance enhancement becomes more effective when heating a mixture of CF x and citric acid (CA) since CA serves as an extra carbon source. Discharge experiments show that the thermal treatment not only reduces initial voltage delay, but also raises discharge voltage. Whereas the measurement of powder impedance indicates the thermal treatment does not increase electronic conductivity of CF x material. Based on these facts, we propose that the thermal treatment results in a limited decomposition of CF x, which yields a subfluorinated carbon (CF x- δ), instead of a highly conductive carbon. In the case of CF x/AC mixture, the AC provides extra carbon that reacts with F 2 and fluorocarbon radicals generated by the thermal decomposition of CF x to form subfluorinated carbon. The process of thermal treatment is studied by thermogravimetric analysis and X-ray diffraction, and the effect of treatment conditions such as heating temperature, heating time and CF x/CA ratio on the discharge performance of CF x cathode is discussed. As an example, a Li/CF x cell using CF x treated with CA at 500 °C under nitrogen for 2 h achieved theretical specific capacity when being discharged at C/5. Impedance analysis indicates that the enhanced performance is attributed to a significant reduction in the cell reaction resistance.

  18. Structural and electrochemical properties of iron- and nickel-substituted Li2MnO3 cathodes in charged and discharged states

    NASA Astrophysics Data System (ADS)

    Yuge, Ryota; Kuroshima, Sadanori; Toda, Akio; Miyazaki, Takashi; Tabuchi, Mitsuharu; Doumae, Kyosuke; Shibuya, Hideka; Tamura, Noriyuki

    2017-10-01

    Structural change and the charge compensation mechanism of lithium-rich layered cathode (Li1.23Fe0.15Ni0.15Mn0.46O2) in charged and discharged states were investigated. Selected area electron diffraction analysis revealed that in discharged state, an initial structure composed of a single phase of monoclinic layered rock-salt changed to a mixture of hexagonal layered rock-salt and spinel-like structures. In charged state, the spinel-like phase became dominant as transition-metal ions migrate. 57Fe Mössbauer spectroscopy, X-ray absorption spectroscopy (XAS), and Soft-XAS showed that the valence of Fe and Ni ions approximately changed from Fe3+ to Fe3.2+ and Ni2+ to Ni3.5+ during charge-discharge, although Mn ions remained as Mn4+. Various oxidation states of oxide ions such as superoxide, peroxide, and hole states have also been detected in charged state. Considering that actual discharge capacity was 255 mAh/g, the contribution to charge compensation from the valence change of Fe and Ni ions was extremely small, and it only contributed to about one-third of total capacity. Therefore, the mechanism to yield high capacity of the Li1.23Fe0.15Ni0.15Mn0.46O2 cathode relates strongly to the redox reaction of oxide ions. Moreover, the decrease in capacity during charge-discharge cycling was mainly due to the irreversible redox reaction of Mn, Fe, and oxide ions.

  19. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Refineries § 60.103 Standard for carbon monoxide. Each owner or operator of any fluid catalytic cracking unit... the fluid catalytic cracking unit catalyst regenerator will be operated, or 180 days after initial... discharge or cause the discharge into the atmosphere from any fluid catalytic cracking unit catalyst...

  20. 40 CFR 60.103 - Standard for carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Refineries § 60.103 Standard for carbon monoxide. Each owner or operator of any fluid catalytic cracking unit... the fluid catalytic cracking unit catalyst regenerator will be operated, or 180 days after initial... discharge or cause the discharge into the atmosphere from any fluid catalytic cracking unit catalyst...

  1. CORMIX2: AN EXPERT SYSTEM FOR HYDRODYNAMIC MIXING ZONE ANALYSIS OF CONVENTIONAL AND TOXIC MULTIPORT DIFFUSER DISCHARGES

    EPA Science Inventory

    CORMIX is a series of software systems for the analysis, prediction, and design of aqueous toxic or conventional pollutant discharges into watercourses, with emphasis on the geometry and dilution characteristics of the initial mixing zone. ubsystem CORMIX1 deals with submerged si...

  2. A trilayer separator with dual function for high performance lithium-sulfur batteries

    NASA Astrophysics Data System (ADS)

    Song, Rensheng; Fang, Ruopian; Wen, Lei; Shi, Ying; Wang, Shaogang; Li, Feng

    2016-01-01

    In this article, we propose a trilayer graphene/polypropylene/Al2O3 (GPA) separator with dual function for high performance lithium-sulfur (Li-S) batteries. Graphene is coated on one side of polypropylene (PP) separator, which functions as a conductive layer and an electrolyte reservoir that allows for rapid electron and ion transport. Then Al2O3 particles are coated on the other side to further enhance thermal stability and safety of the graphene coated polypropylene (GCP) separator, which are touched with lithium metal anode in the Li-S battery. The GPA separator shows good thermal stability after heating at 157 °C for 10 min while both GCP and PP separators showing an obvious shrinkage about 10%. The initial discharge specific capacity of Li-S coin cell with a GPA separator could reach 1067.7 mAh g-1 at 0.2C. After 100 discharge/charge cycles, it can still deliver a reversible capacity of as high as 804.4 mAh g-1 with 75% capacity retention. The pouch cells further confirm that the trilayer design has great promise towards practical applications.

  3. Overview of HIT-SI Results and Plans

    NASA Astrophysics Data System (ADS)

    Ennis, D. A.; Akcay, C.; Hansen, C. J.; Hicks, N. K.; Hossack, A. C.; Jarboe, T. R.; Marklin, G. J.; Nelson, B. A.; Victor, B. S.

    2011-10-01

    Experiments in the Helicity Injected Torus-Steady Inductive (HIT-SI) device have achieved record spheromak current amplification during operations in deuterium plasmas. HIT-SI investigates steady inductive helicity injection with the aim of forming and sustaining a high-beta equilibrium in a spheromak geometry using two semi-toroidal injectors. Recent operations in deuterium plasmas have produced toroidal plasma currents greater than 50 kA, with current amplifications (Itor / Iinj) > 3 , and poloidal flux amplifications (ψpol /ψinj) > 10 . High performance deuterium discharges are achieved by initially conditioning the plasma-facing alumina surface of the HIT-SI confinement volume with helium plasmas. During subsequent deuterium operation the alumina surface strongly pumps deuterium, thereby limiting the density in the confinement volume. Additional measurements during high current deuterium discharges demonstrate reduced current and electron density fluctuations, impurity O III ion temperatures up to 50 eV and a toroidal current persistence for 0.6 ms after the injectors are shut off. Progress and plans for the HIT-SI3 configuration, with three injectors mounted on the same side of the confinement volume, will also be presented. Work supported by USDoE and ARRA.

  4. Slow-moving and far-travelled dense pyroclastic flows during the Peach Spring super-eruption

    USGS Publications Warehouse

    Roche, Olivier; Buesch, David C.; Valentine, Greg A.

    2016-01-01

    Explosive volcanic super-eruptions of several hundred cubic kilometres or more generate long run-out pyroclastic density currents the dynamics of which are poorly understood and controversial. Deposits of one such event in the southwestern USA, the 18.8 Ma Peach Spring Tuff, were formed by pyroclastic flows that travelled >170 km from the eruptive centre and entrained blocks up to ~70–90 cm diameter from the substrates along the flow paths. Here we combine these data with new experimental results to show that the flow’s base had high-particle concentration and relatively modest speeds of ~5–20 m s−1, fed by an eruption discharging magma at rates up to ~107–108 m3 s−1 for a minimum of 2.5–10 h. We conclude that sustained high-eruption discharge and long-lived high-pore pressure in dense granular dispersion can be more important than large initial velocity and turbulent transport with dilute suspension in promoting long pyroclastic flow distance.

  5. Performance Effects of Adding a Parallel Capacitor to a Pulse Inductive Plasma Accelerator Powertrain

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Sivak, Amy D.; Balla, Joseph V.

    2011-01-01

    Pulsed inductive plasma accelerators are electrodeless space propulsion devices where a capacitor is charged to an initial voltage and then discharged through a coil as a high-current pulse that inductively couples energy into the propellant. The field produced by this pulse ionizes the propellant, producing a plasma near the face of the coil. Once a plasma is formed if can be accelerated and expelled at a high exhaust velocity by the Lorentz force arising from the interaction of an induced plasma current and the magnetic field. While there are many coil geometries that can be employed to inductively accelerate a plasma, in this paper the discussion is limit to planar geometries where the coil take the shape of a flat spiral. A recent review of the developmental history of planar-geometry pulsed inductive thrusters can be found in Ref. [1]. Two concepts that have employed this geometry are the Pulsed Inductive Thruster (PIT) and the Faraday Accelerator with Radio-frequency Assisted Discharge (FARAD).

  6. Current halo structures in high-current plasma experiments: θ-pinch

    NASA Astrophysics Data System (ADS)

    Matveev, Yu. V.

    2007-03-01

    Experimental data elucidating mechanisms for halo formation in θ-pinch discharges are presented and discussed. The experiments were performed with different gases (H2, D2, He, and Ar) in a theta-pinch device with a porcelain vacuum chamber and an excitation coil 15 cm in diameter and 30 cm in length. The stored energy, the current in the excitation coil, and the current half-period were W = 10 kJ, I = 400 kA, and T/2 = 14 μs, respectively. It is found that the plasma rings (halos) surrounding the pinch core arise as a result of coaxial pinch stratification due to both the excitation of closed currents (inductons) inside the pinch and the radial convergence of the plasma current sheaths produced after the explosion of T-layers formed near the wall in the initial stage of the discharge. It is concluded that halo structures observed in pinches, tokamaks, and other high-current devices used in controlled fusion research have the same nature.

  7. Graphene nanosheets and polyacrylic acid grafted silicon composite anode for lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Assresahegn, Birhanu Desalegn; Ossonon, Benjamin Diby; Bélanger, Daniel

    2018-07-01

    A silicon/graphene composite anode for lithium-ion batteries was fabricated with a high loading of Si by combining surface-modified silicon with graphene. The Si nanopowder was modified by a binder-like organic moeity (1-(bromoethyl) benzene and polyacrylic acid) grafted on the surface of hydrogenated silicon by diazonium chemistry and surface initiated atom transfer radical polymerization. The graphene was produced by electrochemical exfoliation of natural graphite. The optimum composite electrode prepared without a binder, with silicon loading as high as 85 wt% and a mass loading of 1.1 ± 0.1 mg cm-2 yielded a discharge capacity of 1020 mAh per gram of electrode mass (or 1200 mAh per gram of Si) after 586 charge/discharge cycles at a rate of 3.4 A g-1. It showed first cycle Coulombic efficiency of more than 90% in the absence of electrolyte additives at a current rate of 0.05 A g-1.

  8. Engaging patients via mobile phone technology to assist follow-up after hospitalization in Quito, Ecuador.

    PubMed

    Maslowsky, Julie; Valsangkar, Bina; Chung, Jennifer; Rasanathan, Jennifer; Cruz, Freddy Trujillo; Ochoa, Marco; Chiriboga, Monica; Astudillo, Fernando; Heisler, Michele; Merajver, Sofia

    2012-05-01

    Disease management following hospital discharge is difficult in most low-resourced areas, posing a major obstacle to health equity. Although mobile phones are a ubiquitous and promising technology to facilitate healthcare access, few studies have tested the acceptability and feasibility of patients themselves using the devices for assisting linkages to healthcare services. We hypothesized that patients would use mobile phones to help manage postdischarge problems, if given a communication protocol. We developed a mobile phone-based program and investigated its acceptability and feasibility as a method of delivering posthospitalization care. A consecutive cohort of adult patients in a public hospital in Quito, Ecuador was enrolled over a 1-month period. A hospital-based nurse relayed patients' discharge instructions to a community-based nurse. Patients corresponded with this nurse via text messaging and phone calls according to a protocol to initiate and participate in follow-up. Eighty-nine percent of eligible patients participated. Ninety-seven percent of participants completed at least one contact with the nurse; 81% initiated contact themselves. Nurses completed 262 contacts with 32 patients, clarifying discharge instructions, providing preventive education, and facilitating clinic appointments. By this method, 87% of patients were successfully linked to follow-up appointments. High levels of patient participation and successful delivery of follow-up services indicate the mobile phone program's acceptability and feasibility for facilitating posthospitalization follow-up. Patients actively used mobile phones to interact with nurses, enabling the provision of posthospitalization medical advice and facilitate community-based care via mobile phone.

  9. Measuring and Predicting Long-Term Outcomes in Older Survivors of Critical Illness

    PubMed Central

    Baldwin, Matthew R.

    2015-01-01

    Older adults (age ≥65 years) now initially survive what were previously fatal critical illnesses, but long-term mortality and disability after critical illness remain high. Most studies show that the majority of deaths among older ICU survivors occur during the first 6 to 12 months after hospital discharge. Recent studies of older ICU survivors have created a new standard for longitudinal critical care outcomes studies with a systematic evaluation of pre-critical illness comorbidities and disability and detailed assessments of physical and cognitive function after hospital discharge. These studies show that after controlling for pre-morbid health, older ICU survivors experience large and persistent declines in cognitive and physical function after critical illness. Long-term health-related quality-of-life studies suggest that some older ICU survivors may accommodate to a degree of physical disability and still report good emotional and social well-being, but these studies are subject to survivorship and proxy-response bias. In order to risk-stratify older ICU survivors for long-term (6–12 month) outcomes, we will need a paradigm shift in the timing and type of predictors measured. Emerging literature suggests that the initial acuity of critical illness will be less important, whereas pre-hospitalization estimates of disability and frailty, and, in particular, measures of comorbidity, frailty, and disability near the time of hospital discharge will be essential in creating reliable long-term risk-prediction models. PMID:24923682

  10. Suppression of Instability of High Pressure DC Microplasma Operating in the Negative Differential Resistance (NDR) Regime

    NASA Astrophysics Data System (ADS)

    Mahamud, Rajib; Farouk, Tanvir I.

    2015-09-01

    Microplasma devices have been the subject of considerable interest and research during the last decade. In a DC system most of the operation regime of the plasma discharges studied fall in the ``abnormal,'' ``normal'' and ``corona'' modes - where a quasi-steady state is achieved. It is well known that even in a DC system the negative differential resistance (NDR) regime can trigger self pulsing discharges. These pulsations are initiated by the parasitic capacitance of the system hence governed by the response time of the power circuit. The circuit response time is required to be larger than the ion transit time to initiate the oscillations. In this present study a suppressor circuit element in the form of an inductor is used to restrain the plasma from switching to a self pulsing mode. It has been identified that the combined response time of the inductor and the plasma discharge (L/Rplasma) has to be larger than the power circuit time constant (RC) to achieve suppression. Inhibition of oscillation has been observed in both experiments and numerical simulations. The obtained voltage-current characteristics show that the inductor element extends the normal glow regime to lower current. Additional parametric simulations are conducted to map out a ``stable'' operation regime. The author would like to thank DARPA (ARO Grant No. W911NF1210007) and University of South Carolina (USC) for the financial support of the work.

  11. Alcohol, Hospital Discharge, and Socioeconomic Risk Factors for Default from Multidrug Resistant Tuberculosis Treatment in Rural South Africa: A Retrospective Cohort Study

    PubMed Central

    Kendall, Emily A.; Theron, Danie; Franke, Molly F.; van Helden, Paul; Victor, Thomas C.; Murray, Megan B.; Warren, Robin M.; Jacobson, Karen R.

    2013-01-01

    Background Default from multidrug-resistant tuberculosis (MDR-TB) treatment remains a major barrier to cure and epidemic control. We sought to identify patient risk factors for default from MDR-TB treatment and high-risk time periods for default in relation to hospitalization and transition to outpatient care. Methods We retrospectively analyzed a cohort of 225 patients who initiated MDR-TB treatment between 2007 through 2010 at a rural TB hospital in the Western Cape Province, South Africa. Results Fifty percent of patients were cured or completed treatment, 27% defaulted, 14% died, 4% failed treatment, and 5% transferred out. Recent alcohol use was common (63% of patients). In multivariable proportional hazards regression, older age (hazard ratio [HR]= 0.97 [95% confidence interval 0.94-0.99] per year of greater age), formal housing (HR=0.38 [0.19-0.78]), and steady employment (HR=0.41 [0.19-0.90]) were associated with decreased risk of default, while recent alcohol use (HR=2.1 [1.1-4.0]), recent drug use (HR=2.0 [1.0-3.6]), and Coloured (mixed ancestry) ethnicity (HR=2.3 [1.1-5.0]) were associated with increased risk of default (P<0.05). Defaults occurred throughout the first 18 months of the two-year treatment course but were especially frequent among alcohol users after discharge from the initial four-to-five-month in-hospital phase of treatment, with the highest default rates occurring among alcohol users within two months of discharge. Default rates during the first two months after discharge were also elevated for patients who received care from mobile clinics. Conclusions Among patients who were not cured or did not complete MDR-TB treatment, the majority defaulted from treatment. Younger, economically-unstable patients and alcohol and drug users were particularly at risk. For alcohol users as well as mobile-clinic patients, the early outpatient treatment phase is a high-risk period for default that could be targeted in efforts to increase treatment completion rates. PMID:24349518

  12. Alcohol, hospital discharge, and socioeconomic risk factors for default from multidrug resistant tuberculosis treatment in rural South Africa: a retrospective cohort study.

    PubMed

    Kendall, Emily A; Theron, Danie; Franke, Molly F; van Helden, Paul; Victor, Thomas C; Murray, Megan B; Warren, Robin M; Jacobson, Karen R

    2013-01-01

    Default from multidrug-resistant tuberculosis (MDR-TB) treatment remains a major barrier to cure and epidemic control. We sought to identify patient risk factors for default from MDR-TB treatment and high-risk time periods for default in relation to hospitalization and transition to outpatient care. We retrospectively analyzed a cohort of 225 patients who initiated MDR-TB treatment between 2007 through 2010 at a rural TB hospital in the Western Cape Province, South Africa. Fifty percent of patients were cured or completed treatment, 27% defaulted, 14% died, 4% failed treatment, and 5% transferred out. Recent alcohol use was common (63% of patients). In multivariable proportional hazards regression, older age (hazard ratio [HR]= 0.97 [95% confidence interval 0.94-0.99] per year of greater age), formal housing (HR=0.38 [0.19-0.78]), and steady employment (HR=0.41 [0.19-0.90]) were associated with decreased risk of default, while recent alcohol use (HR=2.1 [1.1-4.0]), recent drug use (HR=2.0 [1.0-3.6]), and Coloured (mixed ancestry) ethnicity (HR=2.3 [1.1-5.0]) were associated with increased risk of default (P<0.05). Defaults occurred throughout the first 18 months of the two-year treatment course but were especially frequent among alcohol users after discharge from the initial four-to-five-month in-hospital phase of treatment, with the highest default rates occurring among alcohol users within two months of discharge. Default rates during the first two months after discharge were also elevated for patients who received care from mobile clinics. Among patients who were not cured or did not complete MDR-TB treatment, the majority defaulted from treatment. Younger, economically-unstable patients and alcohol and drug users were particularly at risk. For alcohol users as well as mobile-clinic patients, the early outpatient treatment phase is a high-risk period for default that could be targeted in efforts to increase treatment completion rates.

  13. Neonates and Infants Discharged Home Dependent on Medical Technology: Characteristics and Outcomes.

    PubMed

    Toly, Valerie Boebel; Musil, Carol M; Bieda, Amy; Barnett, Kimberly; Dowling, Donna A; Sattar, Abdus

    2016-10-01

    Preterm neonates and neonates with complex conditions admitted to a neonatal intensive care unit (NICU) may require medical technology (eg, supplemental oxygen, feeding tubes) for their continued survival at hospital discharge. Medical technology introduces another layer of complexity for parents, including specialized education about neonatal assessment and operation of technology. The transition home presents a challenge for parents and has been linked with greater healthcare utilization. To determine incidence, characteristics, and healthcare utilization outcomes (emergency room visits, rehospitalizations) of technology-dependent neonates and infants following initial discharge from the hospital. This descriptive, correlational study used retrospective medical record review to examine technology-dependent neonates (N = 71) upon discharge home. Study variables included demographic characteristics, hospital length of stay, and type of medical technology used. Analysis of neonates (n = 22) with 1-year postdischarge data was conducted to identify relationships with healthcare utilization. Descriptive and regression analyses were performed. Approximately 40% of the technology-dependent neonates were between 23 and 26 weeks' gestation, with birth weight of less than 1000 g. Technologies used most frequently were supplemental oxygen (66%) and feeding tubes (46.5%). The mean total hospital length of stay for technology-dependent versus nontechnology-dependent neonates was 108.6 and 25.7 days, respectively. Technology-dependent neonates who were female, with a gastrostomy tube, or with longer initial hospital length of stay were at greater risk for rehospitalization. Assessment and support of families, particularly mothers of technology-dependent neonates following initial hospital discharge, are vital. Longitudinal studies to determine factors affecting long-term outcomes of technology-dependent infants are needed.

  14. Absence of early epileptiform abnormalities predicts lack of seizures on continuous EEG.

    PubMed

    Shafi, Mouhsin M; Westover, M Brandon; Cole, Andrew J; Kilbride, Ronan D; Hoch, Daniel B; Cash, Sydney S

    2012-10-23

    To determine whether the absence of early epileptiform abnormalities predicts absence of later seizures on continuous EEG monitoring of hospitalized patients. We retrospectively reviewed 242 consecutive patients without a prior generalized convulsive seizure or active epilepsy who underwent continuous EEG monitoring lasting at least 18 hours for detection of nonconvulsive seizures or evaluation of unexplained altered mental status. The findings on the initial 30-minute screening EEG, subsequent continuous EEG recordings, and baseline clinical data were analyzed. We identified early EEG findings associated with absence of seizures on subsequent continuous EEG. Seizures were detected in 70 (29%) patients. A total of 52 patients had their first seizure in the initial 30 minutes of continuous EEG monitoring. Of the remaining 190 patients, 63 had epileptiform discharges on their initial EEG, 24 had triphasic waves, while 103 had no epileptiform abnormalities. Seizures were later detected in 22% (n = 14) of studies with epileptiform discharges on their initial EEG, vs 3% (n = 3) of the studies without epileptiform abnormalities on initial EEG (p < 0.001). In the 3 patients without epileptiform abnormalities on initial EEG but with subsequent seizures, the first epileptiform discharge or electrographic seizure occurred within the first 4 hours of recording. In patients without epileptiform abnormalities during the first 4 hours of recording, no seizures were subsequently detected. Therefore, EEG features early in the recording may indicate a low risk for seizures, and help determine whether extended monitoring is necessary.

  15. Absence of early epileptiform abnormalities predicts lack of seizures on continuous EEG

    PubMed Central

    Westover, M. Brandon; Cole, Andrew J.; Kilbride, Ronan D.; Hoch, Daniel B.; Cash, Sydney S.

    2012-01-01

    Objective: To determine whether the absence of early epileptiform abnormalities predicts absence of later seizures on continuous EEG monitoring of hospitalized patients. Methods: We retrospectively reviewed 242 consecutive patients without a prior generalized convulsive seizure or active epilepsy who underwent continuous EEG monitoring lasting at least 18 hours for detection of nonconvulsive seizures or evaluation of unexplained altered mental status. The findings on the initial 30-minute screening EEG, subsequent continuous EEG recordings, and baseline clinical data were analyzed. We identified early EEG findings associated with absence of seizures on subsequent continuous EEG. Results: Seizures were detected in 70 (29%) patients. A total of 52 patients had their first seizure in the initial 30 minutes of continuous EEG monitoring. Of the remaining 190 patients, 63 had epileptiform discharges on their initial EEG, 24 had triphasic waves, while 103 had no epileptiform abnormalities. Seizures were later detected in 22% (n = 14) of studies with epileptiform discharges on their initial EEG, vs 3% (n = 3) of the studies without epileptiform abnormalities on initial EEG (p < 0.001). In the 3 patients without epileptiform abnormalities on initial EEG but with subsequent seizures, the first epileptiform discharge or electrographic seizure occurred within the first 4 hours of recording. Conclusions: In patients without epileptiform abnormalities during the first 4 hours of recording, no seizures were subsequently detected. Therefore, EEG features early in the recording may indicate a low risk for seizures, and help determine whether extended monitoring is necessary. PMID:23054233

  16. Design of a New Built-in UHF Multi-Frequency Antenna Sensor for Partial Discharge Detection in High-Voltage Switchgears.

    PubMed

    Zhang, Xiaoxing; Cheng, Zheng; Gui, Yingang

    2016-07-26

    In this study a new built-in ultrahigh frequency (UHF) antenna sensor was designed and applied in a high-voltage switchgear for partial discharge (PD) detection. The casing of the switchgear was initially used as the ground plane of the antenna sensor, which integrated the sensor into the high-voltage switchgear. The Koch snowflake patch was adopted as the radiation patch of the antenna to overcome the disadvantages of common microstrip antennas, and the feed position and the dielectric layer thickness were simulated in detail. Simulation results show that the antenna sensor possessed four resonant points with good impedance matching from 300 MHz to 1000 MHz, and it also presented good multi-frequency performance in the entire working frequency band. PD detection experiments were conducted in the high-voltage switchgear, and the fabricated antenna sensor was effectively built into the high-voltage switchgear. In order to reflect the advantages of the built-in antenna sensor, another external UHF antenna sensor was used as a comparison to simultaneously detect PD. Experimental results demonstrated that the built-in antenna sensor possessed high detection sensitivity and strong anti-interference capacity, which ensured the practicability of the design. In addition, it had more high-voltage switchgear PD detection advantages than the external sensor.

  17. Design of a New Built-in UHF Multi-Frequency Antenna Sensor for Partial Discharge Detection in High-Voltage Switchgears

    PubMed Central

    Zhang, Xiaoxing; Cheng, Zheng; Gui, Yingang

    2016-01-01

    In this study a new built-in ultrahigh frequency (UHF) antenna sensor was designed and applied in a high-voltage switchgear for partial discharge (PD) detection. The casing of the switchgear was initially used as the ground plane of the antenna sensor, which integrated the sensor into the high-voltage switchgear. The Koch snowflake patch was adopted as the radiation patch of the antenna to overcome the disadvantages of common microstrip antennas, and the feed position and the dielectric layer thickness were simulated in detail. Simulation results show that the antenna sensor possessed four resonant points with good impedance matching from 300 MHz to 1000 MHz, and it also presented good multi-frequency performance in the entire working frequency band. PD detection experiments were conducted in the high-voltage switchgear, and the fabricated antenna sensor was effectively built into the high-voltage switchgear. In order to reflect the advantages of the built-in antenna sensor, another external UHF antenna sensor was used as a comparison to simultaneously detect PD. Experimental results demonstrated that the built-in antenna sensor possessed high detection sensitivity and strong anti-interference capacity, which ensured the practicability of the design. In addition, it had more high-voltage switchgear PD detection advantages than the external sensor. PMID:27472331

  18. Formation of Sn–M (M=Fe, Al, Ni) alloy nanoparticles by DC arc-discharge and their electrochemical properties as anodes for Li-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Song; Huang, Hao, E-mail: huanghao@dlut.edu.cn; Wu, Aimin

    2016-10-15

    A direct current arc-discharge method was applied to prepare the Sn–M (M=Fe, Al, Ni) bi-alloy nanoparticles. Thermodynamic is introduced to analyze the energy circumstances for the formation of the nanoparticles during the physical condensation process. The electrochemical properties of as-prepared Sn–M alloy nanoparticles are systematically investigated as anodes of Li-ion batteries. Among them, Sn–Fe nanoparticles electrode exhibits high Coulomb efficiency (about 71.2%) in the initial charge/discharge (257.9 mA h g{sup −1}/366.6 mA h g{sup −1}) and optimal cycle stability (a specific reversible capacity of 240 mA h g{sup −1} maintained after 20 cycles) compared with others. Large differences in themore » electrochemical behaviors indicate that the chemical composition and microstructure of the nanoparticles determine the lithium-ion storage properties and the long-term cyclic stability during the charge/discharge process. - Graphical abstract: The growth mechanism and electrochemical performance of Sn-based alloy nanoparticles. - Highlights: • Thermodynamic analyses of oxides on Sn-M nanoparticles surface. • The relationship between chemical components and electrochemical responses. • Sn-Fe nanoparticles show excellent electrode performance.« less

  19. Potential ballast water transfer of organisms from the west to the east coast of India: Insights through on board sampling

    NASA Astrophysics Data System (ADS)

    Desai, Dattesh V.; Narale, Dhiraj; Khandeparker, Lidita; Anil, Arga Chandrashekar

    2018-03-01

    The possibility of translocation of organisms via ship's ballast water (BW) during a voyage from Hazira on the west coast to Visakhapatnam on the east coast of India was assessed. Samples of BW during the voyage and discharge and sediment collected subsequent to discharge of BW were collected and analyzed for different abiotic and biotic components. It was observed that the salinity did not change, whereas temperature and pH of BW increased marginally during the voyage. A marginal increase in the dissolved oxygen is observed during rough-very rough sea conditions. A sharp decline in the phytoplankton and zooplankton abundance observed in the initial ballast tank sample compared to natural seawater indicates the impact of ballast water pumping on the plankton community. Changes in the sea state during the voyage (slight-moderate to rough-very rough) resulted in a higher sediment suspension rate and suspended particulate matter and this coincided with higher bacterial abundance followed by increase in phytoplankton. An increase in the phytoplankton abundance in the discharge water could be attributed to the inoculum from the sediment. The abundance of zooplankton decreased from the start till the end of the voyage, with high numbers of dead zooplankton in the discharge sample.

  20. Quantifying Neonatal Sucking Performance: Promise of New Methods.

    PubMed

    Capilouto, Gilson J; Cunningham, Tommy J; Mullineaux, David R; Tamilia, Eleonora; Papadelis, Christos; Giannone, Peter J

    2017-04-01

    Neonatal feeding has been traditionally understudied so guidelines and evidence-based support for common feeding practices are limited. A major contributing factor to the paucity of evidence-based practice in this area has been the lack of simple-to-use, low-cost tools for monitoring sucking performance. We describe new methods for quantifying neonatal sucking performance that hold significant clinical and research promise. We present early results from an ongoing study investigating neonatal sucking as a marker of risk for adverse neurodevelopmental outcomes. We include quantitative measures of sucking performance to better understand how movement variability evolves during skill acquisition. Results showed the coefficient of variation of suck duration was significantly different between preterm neonates at high risk for developmental concerns (HRPT) and preterm neonates at low risk for developmental concerns (LRPT). For HRPT, results indicated the coefficient of variation of suck smoothness increased from initial feeding to discharge and remained significantly greater than healthy full-term newborns (FT) at discharge. There was no significant difference in our measures between FT and LRPT at discharge. Our findings highlight the need to include neonatal sucking assessment as part of routine clinical care in order to capture the relative risk of adverse neurodevelopmental outcomes at discharge. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Test Results of a Ten Cell Bipolar Nickel-hydrogen Battery

    NASA Technical Reports Server (NTRS)

    Cataldo, R. L.

    1984-01-01

    A study was initiated to design and evaluate a new design concept for nickel-hydrogen cells. This concept involved constructing a battery in a bipolar stack with cells consisting of a one plate for each nickel and hydrogen electrode. Preliminary designs at the system level of this concept promised improvements in both volumetric and gravimetric energy densities, thermal management, life extension, costs, and peak power capability over more conventional designs. Test results were most encouraging. This preprototype battery, built with less than ideal components and hardware, exceeded expectations. A total of 2000 LEO cycles at 80 percent depth of discharge were accrued. A cycle life goal of 30,000 cycles appears achievable with minor design changes. These improvements include advanced technology nickel electrodes, insulated bipolar plates and specifically designed frames to minimize shunt currents. The discharge rate capability of this design exceeds 25C. At the 10C discharge rate, 80% of the battery capacity can be withdrawn in six minutes. This data shows that the bipolar design is well suited for those applications requiring high peak power pulses.

  2. Using of fiber-array diagnostic to measure the propagation of fast axial ionization wave during breakdown of electrically exploding tungsten wire in vacuum.

    PubMed

    Shi, Huantong; Zou, Xiaobing; Wang, Xinxin

    2017-12-01

    The physical process of electrical explosion of wires in vacuum is featured with the surface discharge along the wire, which generates the corona plasma layer and terminates the Joule heating of the wire core. In this paper, a fiber-array probe was designed to directly measure the radiation of surface arc with spatial and temporal resolution. The radiation of the exploding wire was casted to the section of an optical-fiber-array by a lens and transmitted to PIN diodes and finally collected with an oscilloscope. This probe enables direct diagnostics of the evolution of surface discharge with high temporal resolution and certain spatial resolution. The radiation of a tungsten wire driven by a positive current pulse was measured, and results showed that surface discharge initiates near the cathode and propagates toward the anode with a speed of 7.7 ± 1.6 mm/ns; further estimations showed that this process is responsible for the "conical" structure of the exploding wire.

  3. Microplasma discharge vacuum ultraviolet photoionization source for atmospheric pressure ionization mass spectrometry.

    PubMed

    Symonds, Joshua M; Gann, Reuben N; Fernández, Facundo M; Orlando, Thomas M

    2014-09-01

    In this paper, we demonstrate the first use of an atmospheric pressure microplasma-based vacuum ultraviolet (VUV) photoionization source in atmospheric pressure mass spectrometry applications. The device is a robust, easy-to-operate microhollow cathode discharge (MHCD) that enables generation of VUV photons from Ne and Ne/H(2) gas mixtures. Photons were detected by excitation of a microchannel plate detector and by analysis of diagnostic sample ions using a mass spectrometer. Reactive ions, charged particles, and metastables produced in the discharge were blocked from entering the ionization region by means of a lithium fluoride window, and photoionization was performed in a nitrogen-purged environment. By reducing the output pressure of the MHCD, we observed heightened production of higher-energy photons, making the photoionization source more effective. The initial performance of the MHCD VUV source has been evaluated by ionizing model analytes such as acetone, azulene, benzene, dimethylaniline, and glycine, which were introduced in solid or liquid phase. These molecules represent species with both high and low proton affinities, and ionization energies ranging from 7.12 to 9.7 eV.

  4. Effects of mecamylamine on responses of carotid body chemoreceptors in vivo to physiological and pharmacological stimuli

    PubMed Central

    Sampson, S. R.

    1971-01-01

    1. Effects of mecamylamine on the spontaneous discharge rate of afferent fibres of carotid body chemoreceptors in vivo and their responses to ACh, NaCN, HCl and hypoxia were studied in sixteen cats. 2. Cats were anaesthetized with sodium pentobarbitone, paralysed with gallamine triethiodide and artificially ventilated. Chemoreceptor excitants were injected into the common carotid artery; mecamylamine was given intravenously. 3. Mecamylamine, 230 μg/kg or greater, failed to diminish either the rate of spontaneous discharge of carotid body chemoreceptors at high arterial oxygen tensions (greater than 130 mm Hg), or the responses of these receptors to NaCN (0·5-25 μg), HCl or hypoxic blood. 4. Responses of chemoreceptor afferent fibres to ACh (1·0-50 μg) in the same preparations were either completely abolished or considerably reduced by mecamylamine. 5. These data do not support the hypothesis of a cholinergic mechanism for the initiation of chemosensory discharges in the carotid body, either at rest or in response to stimuli such as NaCN, acid or hypoxia. PMID:5557066

  5. Using of fiber-array diagnostic to measure the propagation of fast axial ionization wave during breakdown of electrically exploding tungsten wire in vacuum

    NASA Astrophysics Data System (ADS)

    Shi, Huantong; Zou, Xiaobing; Wang, Xinxin

    2017-12-01

    The physical process of electrical explosion of wires in vacuum is featured with the surface discharge along the wire, which generates the corona plasma layer and terminates the Joule heating of the wire core. In this paper, a fiber-array probe was designed to directly measure the radiation of surface arc with spatial and temporal resolution. The radiation of the exploding wire was casted to the section of an optical-fiber-array by a lens and transmitted to PIN diodes and finally collected with an oscilloscope. This probe enables direct diagnostics of the evolution of surface discharge with high temporal resolution and certain spatial resolution. The radiation of a tungsten wire driven by a positive current pulse was measured, and results showed that surface discharge initiates near the cathode and propagates toward the anode with a speed of 7.7 ± 1.6 mm/ns; further estimations showed that this process is responsible for the "conical" structure of the exploding wire.

  6. Preliminary Results Of A 600 Joules Small Plasma Focus Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S. H.; Yap, S. L.; Wong, C. S.

    Preliminary results of a 600 J (3.7 muF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltagemore » across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0+-0.5 mubar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.« less

  7. Improving transition of care for veterans after total joint replacement.

    PubMed

    Green, Uthona R; Dearmon, Valorie; Taggart, Helen

    2015-01-01

    Patients transitioning from hospital to home are at risk for readmission to the hospital. Readmissions are costly and occur too often. Standardized discharge education processes have shown to decrease readmissions. The purpose of this quality improvement project was to utilize evidence-based practice changes to decrease 30-day all-cause readmissions after total joint replacement. Review of literature revealed that improved discharge education can decrease unnecessary readmissions after discharge. A quality improvement project was developed including standardized total joint replacement discharge education, teach-back education methodology, and improved postdischarge telephone follow-up. The quality improvement project was initiated and outcomes were evaluated. Improving coordination of the discharge process, enhanced education for patients/caregivers, and postdischarge follow-up decreased total joint replacement readmissions.

  8. Ionization processes in combined high-voltage nanosecond - laser discharges in inert gas

    NASA Astrophysics Data System (ADS)

    Starikovskiy, Andrey; Shneider, Mikhail; PU Team

    2016-09-01

    Remote control of plasmas induced by laser radiation in the atmosphere is one of the challenging issues of free space communication, long-distance energy transmission, remote sensing of the atmosphere, and standoff detection of trace gases and bio-threat species. Sequences of laser pulses, as demonstrated by an extensive earlier work, offer an advantageous tool providing access to the control of air-plasma dynamics and optical interactions. The avalanche ionization induced in a pre-ionized region by infrared laser pulses where investigated. Pre-ionization was created by an ionization wave, initiated by high-voltage nanosecond pulse. Then, behind the front of ionization wave extra avalanche ionization was initiated by the focused infrared laser pulse. The experiment was carried out in argon. It is shown that the gas pre-ionization inhibits the laser spark generation under low pressure conditions.

  9. Efficacy of vitamin D3 supplementation in reducing incidence of pulmonary tuberculosis and mortality among HIV-infected Tanzanian adults initiating antiretroviral therapy: study protocol for a randomized controlled trial.

    PubMed

    Sudfeld, Christopher R; Mugusi, Ferdinand; Aboud, Said; Nagu, Tumaini J; Wang, Molin; Fawzi, Wafaie W

    2017-02-10

    HIV-infected adults initiating antiretroviral therapy (ART) in sub-Saharan Africa continue to experience high rates of morbidity and mortality during the initial months of treatment. Observational studies in high-income and resource-limited settings indicate that HIV-infected adults with low vitamin D levels may be at increased risk of mortality, HIV disease progression, and incidence of pulmonary tuberculosis (TB). As a result, vitamin D 3 supplementation may improve survival and treatment outcomes for HIV-infected adults initiating ART. The Trial of Vitamins-4 (ToV4) is an individually randomized, double-blind, placebo-controlled trial of vitamin D 3 (cholecalciferol) supplementation conducted among 4000 HIV-infected adults with low vitamin D levels [25-hydroxyvitamin D (25(OH)D) <30 ng/mL] initiating ART in Dar es Salaam, Tanzania. The two primary aims of the trial are to determine the effect of a vitamin D 3 supplementation regimen on incidence of (1) mortality and (2) pulmonary TB as compared to a matching placebo regimen. The primary safety outcome of the study is incident hypercalcemia. The investigational vitamin D 3 regimen consists of oral supplements containing 50,000 IU vitamin D 3 taken under direct observation at randomization and once a week for 3 weeks (four doses) followed by daily oral supplements containing 2000 IU vitamin D 3 taken at home from the fourth week until trial discharge at 1 year post ART initiation. Trial participants are followed up at weekly clinic visits during the first month of ART and at monthly clinic visits thereafter until trial discharge at 1 year post ART initiation. Secondary aims of the trial are to examine the effect of the vitamin D 3 regimen on CD4 T cell reconstitution, incidence of non-TB comorbidities, body mass index (BMI), depression and anxiety, physical activity, bone health, and immunologic biomarkers. The ToV4 will provide causal evidence on the effect of vitamin D 3 supplementation on incidence of pulmonary TB and mortality among HIV-infected Tanzanian adults initiating ART. The trial will also give insight to whether vitamin D 3 supplementation trials for the prevention of pulmonary TB should be pursued in HIV-uninfected populations. ClinicalTrials.gov, NCT01798680 . Registered on 21 February 2013.

  10. Annual peak discharges from small drainage areas in Montana for stations discontinued before 1978

    USGS Publications Warehouse

    Omang, R.J.; Hull, J.A.; Parrett, Charles

    1979-01-01

    Annual peak stage and discharge data have been tabulated for crest-stage gage sites in Montana. The crest-stage program was begun in July 1955 to investigate the magnitude and frequency of floods from samll drainage areas. The program has expanded from 45 crest-stage gaging stations initially to 172 stations maintained in 1978. From 1955 to 1978, 156 stations have been discontinued. This report is a tabulation of the stage and discharge data for the discontinued stations. (Woodard-USGS)

  11. Spectroscopic characteristics of H α /OI atomic lines generated by nanosecond pulsed corona-like discharge in deionized water

    NASA Astrophysics Data System (ADS)

    Pongrác, Branislav; Šimek, Milan; Člupek, Martin; Babický, Václav; Lukeš, Petr

    2018-03-01

    Basic emission fingerprints of nanosecond discharges produced in deionized water by fast rise-time positive high-voltage pulses (duration of 6 ns and amplitude of  +100 kV) in a point-to-plane electrode geometry were investigated by means of time-resolved intensified charge-coupled device (ICCD) spectroscopy. Time-resolved emission spectra were measured via ICCD kinetic series during the discharge ignition and later phases over the 350-850 nm spectral range with fixed, either 3 ns or 30 ns, acquisition time and with 3 ns or 30 ns time resolution, respectively. The luminous phase of the initial discharge expansion and its subsequent collapse was characterized by a broadband vis-NIR continuum emission evolving during the first few nanoseconds which shifted more toward the UV with further increase of time. After ~30 ns from the discharge onset, the continuum gradually disappeared followed by the emission of H α and OI atomic lines. The electron densities calculated from the H α profile fit were estimated to be of the order of 1018-1019 cm-3. It is unknown if the H α and OI atomic lines are generated even in earlier times (before ~30 ns) because such signals were not detectable due to the superposition with the strong continuum. However, subsequent events caused by the reflected HV pulses were observed to have significant effects on the emission spectra profiles of the nanosecond discharge. By varying the time delay of the reflected pulse from 45 to 90 ns after the primary pulse, the intensities of the H α /OI atomic lines in the emission spectra of the secondary discharges were clearly visible and their intensities were greater with shorter time delay between primary and reflected pulses. These results indicate that the discharges generated due to the reflected pulses were very likely generated in the non-relaxed environment.

  12. Monovalent manganese based anodes and co-solvent electrolyte for stable low-cost high-rate sodium-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Firouzi, Ali; Qiao, Ruimin; Motallebi, Shahrokh

    The demand of sustainable power supply requires high-performance cost-effective energy storage technologies. Here in this paperwe report a high-rate long-life low-cost sodium-ion battery full-cell system by innovating both the anode and the electrolyte. The redox couple of manganese(I/II) in Prussian blue analogs enables a high-rate and stable anode. Soft X-ray absorption spectroscopy and resonant inelastic X-ray scattering provide direct evidence suggesting the existence of monovalent manganese in the charged anode. There is a strong hybridization between cyano ligands and manganese-3d states, which benefits the electronic property for improving rate performance. Additionally, we employ an organic-aqueous cosolvent electrolyte to solve themore » long-standing solubility issue of Prussian blue analogs. A full-cell sodium-ion battery with low-cost Prussian blue analogs in both electrodes and co-solvent electrolyte retains 95% of its initial discharge capacity after 1000 cycles at 1C and 9 5% depth of discharge. The revealed manganese(I/II) redox couple inspires conceptual innovations of batteries based on atypical oxidation states.« less

  13. Recovery from severe dysphagia in systemic sclerosis - myositis overlap: a case report.

    PubMed

    Chinniah, Keith J; Mody, Girish M

    2017-06-01

    Dysphagia is common in inflammatory myopathies and usually responds to corticosteroids. Severe dysphagia requiring feeding by percutaneous endoscopic gastrostomy is associated with significant morbidity and high mortality. A 56-year old African Black woman initially presented with systemic sclerosis (SSC) - myositis overlap and interstitial lung disease. She responded to high dose corticosteroids and cyclophosphamide followed by azathioprine, with improvement in her lung function and regression of the skin changes. Six years later she had a myositis flare with severe dysphagia. Her myositis improved after high doses of corticosteroids, azathioprine and two doses of intravenous immunoglobulin (IVIG). As her dysphagia persisted, she was fed via a percutaneous endoscopic gastrostomy (PEG) tube and given a course of rituximab. Her dysphagia gradually resolved and the PEG tube was removed within two months. She received another dose of rituximab six months later and continued low dose prednisone and azathioprine. Her muscle power improved, weight returned to normal and she remained well 20 months after hospital discharge. Our patient with SSC-myositis overlap and severe dysphagia requiring PEG feeding, improved with high dose corticosteroids, azathioprine, two courses of IVIG and rituximab, and remained in remission 20 months after hospital discharge.

  14. Monovalent manganese based anodes and co-solvent electrolyte for stable low-cost high-rate sodium-ion batteries

    DOE PAGES

    Firouzi, Ali; Qiao, Ruimin; Motallebi, Shahrokh; ...

    2018-02-28

    The demand of sustainable power supply requires high-performance cost-effective energy storage technologies. Here in this paperwe report a high-rate long-life low-cost sodium-ion battery full-cell system by innovating both the anode and the electrolyte. The redox couple of manganese(I/II) in Prussian blue analogs enables a high-rate and stable anode. Soft X-ray absorption spectroscopy and resonant inelastic X-ray scattering provide direct evidence suggesting the existence of monovalent manganese in the charged anode. There is a strong hybridization between cyano ligands and manganese-3d states, which benefits the electronic property for improving rate performance. Additionally, we employ an organic-aqueous cosolvent electrolyte to solve themore » long-standing solubility issue of Prussian blue analogs. A full-cell sodium-ion battery with low-cost Prussian blue analogs in both electrodes and co-solvent electrolyte retains 95% of its initial discharge capacity after 1000 cycles at 1C and 9 5% depth of discharge. The revealed manganese(I/II) redox couple inspires conceptual innovations of batteries based on atypical oxidation states.« less

  15. Novel hierarchically porous carbon materials obtained from natural biopolymer as host matrixes for lithium-sulfur battery applications.

    PubMed

    Zhang, Bin; Xiao, Min; Wang, Shuanjin; Han, Dongmei; Song, Shuqin; Chen, Guohua; Meng, Yuezhong

    2014-08-13

    Novel hierarchically porous carbon materials with very high surface areas, large pore volumes and high electron conductivities were prepared from silk cocoon by carbonization with KOH activation. The prepared novel porous carbon-encapsulated sulfur composites were fabricated by a simple melting process and used as cathodes for lithium sulfur batteries. Because of the large surface area and hierarchically porous structure of the carbon material, soluble polysulfide intermediates can be trapped within the cathode and the volume expansion can be alleviated effectively. Moreover, the electron transport properties of the carbon materials can provide an electron conductive network and promote the utilization rate of sulfur in cathode. The prepared carbon-sulfur composite exhibited a high specific capacity and excellent cycle stability. The results show a high initial discharge capacity of 1443 mAh g(-1) and retain 804 mAh g(-1) after 80 discharge/charge cycles at a rate of 0.5 C. A Coulombic efficiency retained up to 92% after 80 cycles. The prepared hierarchically porous carbon materials were proven to be an effective host matrix for sulfur encapsulation to improve the sulfur utilization rate and restrain the dissolution of polysulfides into lithium-sulfur battery electrolytes.

  16. A high time resolution x-ray diagnostic on the Madison Symmetric Torus

    NASA Astrophysics Data System (ADS)

    DuBois, Ami M.; Lee, John David; Almagri, Abdulgadar F.

    2015-07-01

    A new high time resolution x-ray detector has been installed on the Madison Symmetric Torus (MST) to make measurements around sawtooth events. The detector system is comprised of a silicon avalanche photodiode, a 20 ns Gaussian shaping amplifier, and a 500 MHz digitizer with 14-bit sampling resolution. The fast shaping time diminishes the need to restrict the amount of x-ray flux reaching the detector, limiting the system dead-time. With a much higher time resolution than systems currently in use in high temperature plasma physics experiments, this new detector has the versatility to be used in a variety of discharges with varying flux and the ability to study dynamics on both slow and fast time scales. This paper discusses the new fast x-ray detector recently installed on MST and the improved time resolution capabilities compared to the existing soft and hard x-ray diagnostics. In addition to the detector hardware, improvements to the detector calibration and x-ray pulse identification software, such as additional fitting parameters and a more sophisticated fitting routine are discussed. Finally, initial data taken in both high confinement and standard reversed-field pinch plasma discharges are compared.

  17. Nanoscale discharge electrode for minimizing ozone emission from indoor corona devices.

    PubMed

    Bo, Zheng; Yu, Kehan; Lu, Ganhua; Mao, Shun; Chen, Junhong; Fan, Fa-Gung

    2010-08-15

    Ground-level ozone emitted from indoor corona devices poses serious health risks to the human respiratory system and the lung function. Federal regulations call for effective techniques to minimize the indoor ozone production. In this work, stable atmospheric corona discharges from nanomaterials are demonstrated using horizontally suspended carbon nanotubes (CNTs) as the discharge electrode. Compared with the conventional discharges employing micro- or macroscale electrodes, the corona discharge from CNTs could initiate and operate at a much lower voltage due to the small electrode diameter, and is thus energy-efficient. Most importantly, the reported discharge is environmentally friendly since no ozone (below the detection limit of 0.5 ppb) was detected for area current densities up to 0.744 A/m(2) due to the significantly reduced number of electrons and plasma volume generated by CNT discharges. The resulting discharge current density depends on the CNT loading. Contrary to the conventional wisdom, negative CNT discharges should be used to enhance the current density owing to the efficient field emission of electrons from the CNT surface.

  18. Vogt-Koyanagi-Harada syndrome presenting with encephalopathy

    PubMed Central

    Naeini, Alireza E.; Daneshmand, Dana; Khorvash, Farzin; Chitsaz, Ahmad

    2014-01-01

    Vogt-Koyanagi-Harada (VKH) is a rare syndrome affecting tissues containing melanocytes. The possibility of its autoimmune pathogenesis is supported by high frequent HLA-DR4 presentation, commonly associated with other autoimmune diseases. Eyes are the main affected organs, resulting in blindness. Brain disease is a late-onset event, and is extremely rare. Here, we are reporting a 57-year-old woman, a known case of VKH syndrome, presenting with brain encephalopathy several decades after the initial presentation. We think this long period between initial presentation and presentation of encephalopathy due to VKH syndrome has not been described before. She was treated with corticosteroids and discharged home with a good general condition. PMID:24753681

  19. Rocket Propulsion 21 Steering Committee Meeting (RP21) NASA In-Space Propulsion Update

    NASA Technical Reports Server (NTRS)

    Klem, Mark

    2015-01-01

    In-house Support of NEXT-C Contract Status Thruster NEXT Long Duration Test post-test destructive evaluation in progress Findings will be used to verify service life models identify potential design improvements Cathode heater fabrication initiated for cyclic life testing Thruster operating algorithm definition verification initiated to provide operating procedures for mission users High voltage propellant isolator life test voluntarily terminated after successfully operating 51,200 h Power processor unit (PPU) Replaced all problematic stacked multilayer ceramic dual inline pin capacitors within PPU Test bed Rebuilt installed discharge power supply primary power board Completed full functional performance characterization Final test report in progress Transferred PPU Testbed to contractor to support prototype design effort.

  20. Nanosheet-assembled NiO microstructures for high-performance supercapacitors.

    PubMed

    Purushothaman, Kamatchi Kamaraj; Babu, Inbamani Manohara; Sethuraman, Balasubramanian; Muralidharan, Gopalan

    2013-11-13

    Nanosheet-assembled NiO microstructures have been synthesized via a hydrothermal method. The presence of anionic surfactant in the fabrication process initiates the formation of lamellar micelles and a self-assembling process. This leads to the formation of NiO nanosheets and organizes it into microstructures. The effect of preparation temperature on the morphological, structural, and electrochemical properties and stability upon continuous charge/discharge cycles has been examined for supercapacitor applications. Electrochemical analysis demonstrated that NiO nanosheets prepared at 160 °C are capable of delivering a specific capacitance of 989 F g(-1) at a scan rate of 3 mV s(-1) for the potential window of 0-0.6 V. The nanosheets exhibit excellent capacity retention, 97% retention after 1000 continuous charge/discharge cycles, and an energy density of 49.45 W h kg(-1).

  1. Electrochemical and XPS study of LiFePO4 cathode nanocomposite with PPy/PEG conductive network

    NASA Astrophysics Data System (ADS)

    Fedorková, A.; Oriňáková, R.; Oriňák, A.; Kupková, M.; Wiemhöfer, H.-D.; Audinot, J. N.; Guillot, J.

    2012-08-01

    High performance PPy/PEG-LiFePO4 nanocomposites as cathode materials were synthesized by solvothermal method and simple chemical oxidative polymerization of pyrrole (Py) monomer on the surface of LiFePO4 particles. The samples were characterized by scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectrometry (XPS) and charge-discharge tests. PPyPEG hybrid layers decrease particle to particle contact resistance while the impedance measurements confirmed that the coating of PPy-PEG significantly decreases the charge transfer resistance of the electrode material. The initial discharge capacities of this sample at C/5 and 1C are 150 and 128 mAh/g, respectively. The results show that PPy/PEGLiFePO4 composites are more effective than bare LiFePO4 as cathode material.

  2. The fabrication of foam-like 3D mesoporous NiO-Ni as anode for high performance Li-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Peng, E-mail: huangp07@lzu.edu.cn; Department of Physics, Lanzhou University, Lanzhou 730000; Zhang, Xin

    2015-03-15

    Graphical abstract: Foam-like 3 dimensional (3D) mesoporous NiO on 3D micro-porous Ni was fabricated. - Highlights: • We prepare NiO-Ni foam composite via hydrothermal etching and subsequent annealing. • The NiO exhibits novel foam-like 3D mesoporous architecture. • The NiO-Ni anode shows good cycle stability. - Abstract: Foam-like three dimensional mesoporous NiO on Ni foam was fabricated via facile hydrothermal etching and subsequent annealing treatment. The porous NiO consists of a large number of nanosheets with mean thickness about 50 nm, among which a large number of mesoscopic pores with size ranges from 100 nm to 1 μm distribute. Themore » electrochemical performance of the as-prepared NiO-Ni as anode for lithium ion battery was studied by conventional charge/discharge test, which shows excellent cycle stability and rate capability. It exhibits initial discharge and charge capacities of 979 and 707 mA h g{sup −1} at a charge/discharge rate of 0.7 C, which maintain of 747 and 738 mA h g{sup −1} after 100 cycles. Even after 60 cycles at various rates from 0.06 to 14 C, the 10th discharge and charge capacities of the NiO-Ni electrode can revert to 699 and 683 mA h g{sup −1} when lowering the charge/discharge rate to 0.06 C.« less

  3. Development of ambient temperature secondary lithium cells

    NASA Technical Reports Server (NTRS)

    Subbarao, S.; Shen, D. H.; Dawson, S.; Deligiannis, F.; Taraszkiewicz, J.; Halpert, G.

    1988-01-01

    JPL is developing ambient temperature secondary lithium cells for future spacecraft applications. Prior studies on experimental laboratory type Li-TiS2 cells yielded promising results in terms of cycle life and rate capability. To further assess the performance of this cell, 5 Ah engineering model cells were developed. Initially baseline cells were designed and fabricated. Each cell had 15 cathodes and 16 anodes and the ratio of anode to cathode capacity is 6:1. A solution of 1.5 molar LiAsF6 in 2Me-THF was used as the electrolyte. Cells were evaluated for their cycle life at C/1 and C/5 discharge rates and 100 percent depth of discharge. The cells were cycled between voltage limits 1.7 and 2.8 volts. The rate of charge in all cases is C/10. The results obtained indicate that cells can operate at C/10 to C/2 discharge rates and have an initial energy density of 70 Wh/kg. Cells delivered more than 100 cycles at C/2 discharge rate. The details of cell design, the test program, and the results obtained are described.

  4. Development of ambient temperature secondary lithium cells

    NASA Technical Reports Server (NTRS)

    Subbarao, S.; Shen, D. H.; Dawson, S.; Deligiannis, F.; Taraszkiewicz, J.; Halpert, Gerald

    1987-01-01

    JPL is developing ambient temperature secondary lithium cells for future spacecraft applications. Prior studies on experimental laboratory type Li-TiS2 cells yielded promising results in terms of cycle life and rate capability. To further assess the performance of this cell, 5 Ah engineering model cells were developed. Initially baseline cells were designed and fabricated. Each cell had 15 cathodes and 16 anodes and the ratio of anode to cathode capacity is 6:1. A solution of 1.5 molar LiAsF6 in 2Me-THF was used as the electrolyte. Cells were evaluated for their cycle life at C/1 and C/5 discharge rates and 100 percent depth of discharge. The cells were cycled between voltage limits 1.7 and 2.8 volts. The rate of charge in all cases is C/10. The results obtained indicate that cells can operate at C/10 to C/2 discharge rates and have an initial energy density of 70 Wh/kg. Cells delivered more than 100 cycles at C/2 discharge rate. The details of cell design, the test program, and the results obtained are described.

  5. Effect of component compression on the initial performance of an IPV nickel-hydrogen cell

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.

    1987-01-01

    An experimental method was developed for evaluating the effect of component compression on the charge and discharge voltage characteristics of a 3 1/2 in. diameter boiler plate cell. A standard boiler plate pressure vessel was modified by the addition of a mechanical feedthrough on the bottom of the vessel which permitted different compressions to be applied to the components without disturbing the integrity of the stack. Compression loadings from 0.94 to 27.4 psi were applied by suspending weights from the feedthrough rod. Cell voltages were measured for 0.96-C, 55-min charge and for 1.37-C, 35-min and 2-C, 24-min discharges. An initial change in voltage performance on both charge and discharge as the loading increased was attributed to seating of the components. Subsequent variation of the compression from 2.97 to 27.4 psi caused only minor changes in either the charge or the discharge voltages. Several one month open-circuit voltage stands and 1100 cycles under LEO conditions at the maximum loading have produced no change in performance.

  6. Effect of component compression on the initial performance of an IPV nickel-hydrogen cell. [Individual Pressure Vessel

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.

    1987-01-01

    An experimental method was developed for evaluating the effect of component compression on the charge and discharge voltage characteristics of a 3 1/2 in. diameter boiler plate cell. A standard boiler plate pressure vessel was modified by the addition of a mechanical feedthrough on the bottom of the vessel which permitted different compressions to be applied to the components without disturbing the integrity of the stack. Compression loadings from 0.94 to 27.4 psi were applied by suspending weights from the feedthrough rod. Cell voltages were measured for 0.96-C, 55-min charge and for 1.37-C, 35-min and 2-C, 24-min discharges. An initial change in voltage performance on both charge and discharge as the loading increased was attributed to seating of the components. Subsequent variation of the compression from 2.97 to 27.4 psi caused only minor changes in either the charge or the discharge voltages. Several one month open-circuit voltage stands and 1100 cycles under LEO conditions at the maximum loading have produced no change in performance.

  7. How is the high vaginal swab used to investigate vaginal discharge in primary care and how do GPs' expectations of the test match the tests performed by their microbiology services?

    PubMed

    Noble, H; Estcourt, C; Ison, C; Goold, P; Tite, L; Carter, Y H

    2004-06-01

    To describe the management of vaginal discharge in general practice, with particular regard to the use of the high vaginal swab (HVS), and to compare GPs' expectations of this test with the processing and reporting undertaken by different laboratories. A postal questionnaire survey of 2146 GPs in the North Thames area and postal questionnaire study of the 22 laboratories serving the same GPs were carried out. GPs were asked how they would manage a young woman with vaginal discharge and what information they would like on an HVS report. Laboratories were asked how they would process and report on the HVS sample from the same patient. Response rate was 26%. 72% of GPs would take an HVS and 62% would refer on to a genitourinary medicine (GUM) clinic. 45% would offer empirical therapy and 47% of these would treat for candida initially. 75% of GPs routinely request "M,C&S" on HVS samples but 55% only want to be informed about specific pathogens. Routine processing of HVS samples varies widely between laboratories and 86% only report specific pathogens. 78% of GPs would like to be offered a suggested diagnosis on HVS reports, and 74% would like a suggested treatment. 43% of laboratories ever provide a diagnosis, and 14% provide a suggested treatment. GPs frequently manage vaginal discharge and most of them utilise the HVS. GPs' expectations of the test are not well matched to laboratory processing or reporting of the samples.

  8. Evolution and Initial Experience of a Statewide Care Transitions Quality Improvement Collaborative: Preventing Avoidable Readmissions Together.

    PubMed

    Axon, R Neal; Cole, Laura; Moonan, Aunyika; Foster, Richard; Cawley, Patrick; Long, Laura; Turley, Christine B

    2016-02-01

    Increasing scrutiny of hospital readmission rates has spurred a wide variety of quality improvement initiatives. The Preventing Avoidable Readmissions Together (PART) initiative is a statewide quality improvement learning collaborative organized by stakeholder organizations in South Carolina. This descriptive report focused on initial interventions with hospitals. Eligible participants included all acute care hospitals plus home health organizations, nursing facilities, hospices, and other health care organizations. Measures were degree of statewide participation, curricular engagement, adoption of evidence-based improvement strategies, and readmission rate changes. Fifty-nine of 64 (92%) acute care hospitals and 9 of 10 (90%) hospital systems participated in collaborative events. Curricular engagement included: webinars and coaching calls (49/59, 83%), statewide in-person meetings (35/59, 59%), regional in-person meetings (44/59, 75%), and individualized consultations (46/59, 78%). Among 34 (58%) participating hospitals completing a survey at the completion of Year 1, respondents indicated complete implementation of multidisciplinary rounding (58%), post-discharge telephone calls (58%), and teach-back (32%), and implementation in process of high-quality transition records (52%), improved discharge summaries (45%), and timely follow-up appointments (39%). A higher proportion of hospitals had significant decreases (≥10% relative change) in all-cause readmission rates for acute myocardial infarction (55.6% vs. 30.4%, P=0.01), heart failure (54.2% vs. 31.7%, P=0.09), and chronic obstructive pulmonary disease (41.7% vs. 33.3%, P=0.83) between 2011-2013 compared to earlier (2009-2011) trends. Focus on reducing readmissions is driving numerous, sometimes competing, quality improvement initiatives. PART successfully engaged the majority of acute care facilities in one state to harmonize and accelerate adoption of evidence-based care transitions strategies.

  9. Two discharge modes of a repetitive nanosecond pulsed helium glow discharge under sub-atmospheric pressure in the repetition frequency range of 20 to 600 kHz

    NASA Astrophysics Data System (ADS)

    Kikuchi, Yusuke; Maegawa, Takuya; Otsubo, Akira; Nishimura, Yoshimi; Nagata, Masayoshi; Yatsuzuka, Mitsuyasu

    2018-05-01

    Two discharge modes, α and γ, of a repetitive nanosecond pulsed helium glow discharge at a gas pressure of 10 kPa in the repetition frequency range from 20 to 600 kHz are reported for the first time. The pulsed glow discharge is produced in a pair of parallel plate metal electrodes without insertion of dielectrics. The α mode discharge is volumetrically produced in the electrode gap at a low-repetition frequency, whereas the γ mode discharge is localized at the cathode surface at a high-repetition frequency. At high-repetition frequency, the time interval between voltage pulses is shorter than the lifetime of the afterglow produced by the preceding discharge. Then, the γ mode discharge is maintained by a large number of secondary electrons emitted from the cathode exposed to high-density ions and metastable helium atoms in the afterglow. In the α mode discharge with a low-repetition frequency operation, primary electrons due to gas ionization dominate the ionization process. Thus, a large discharge voltage is needed for the excitation of the α mode discharge. It is established that the bifurcation of α-γ discharge mode, accompanied by a decrease in the discharge voltage, occurs at the high-repetition frequency of ∼120 kHz.

  10. Electric Discharge Sintering and Joining of Tungsten Carbide—Cobalt Composite with High-Speed Steel Substrate

    NASA Astrophysics Data System (ADS)

    Grigoryev, Evgeny G.

    2011-01-01

    Simultaneous electro discharge sintering of high strength structure of tungsten carbide—cobalt composite and connection it with high-speed steel substrate is investigated and suitable operating parameters are defined. Tungsten carbide—cobalt and high-speed steel joining was produced by the method of high voltage electrical discharge together with application of mechanical pressure to powder compact. It was found that the density and hardness of composite material reach its maximum values at certain magnitudes of applied pressure and high voltage electrical discharge parameters. We show that there is an upper level for the discharge voltage beyond which the powder of composite material disintegrates like an exploding wire. Due to our results it is possible to determine optimal parameters for simultaneous electro discharge sintering of WC-Co and bonding it with high-speed steel substrate.

  11. Scaling of Dielectric Breakdown Thresholds in Earth's and CO2-rich atmospheres: Impact for Predictions of Extraterrestrial Transient Luminous Events and Lightning Discharges

    NASA Astrophysics Data System (ADS)

    Riousset, J. A.

    2016-12-01

    Earth's atmospheric electricity manifests itself in the form of glow, corona, streamer, and leader discharges observed as Saint Elmo's fire, sprites, lightning and jets discharges, and other Transient Luminous Events (TLEs). All of these are types of dielectric breakdown, but are governed by different physics. In particular, their initiation is associated with the crossing of specific electric field thresholds: relativistic runaway, streamer propagation, conventional breakdown, or thermal runaway thresholds, some better understood than others. For example, the initiation of a lightning discharge is known to occur when the local electric field exceeds a value similar to relativistic runaway field, but the exact threshold, as well as the physical mechanisms at work, remain rather unclear to date. Scaling laws for electric fields (and other quantities) have been established by Pasko et al. [GRL, 25(12), 2123-2126, 1998] and Pasko [NATO Sci. Series, Springer, 253-311, 2006]. In this work, we develop profiles for initiation criteria in air and in other atmospheric environments. We further calculate their associated scaling laws to determine the ability to trigger lightning flashes and TLEs in our solar system. This lets us predict the likelihood of electrical discharges on, e.g., Mars, Venus and Titan, and calculate the expected electric field conditions, under which discharges have been observed on Jupiter, Saturn, Uranus, and Neptune [Leblanc et al., ISSI Spa. Sci. Series, Springer, 2008, Yair, Adv. Space Res., 50(3), 293-310, 2012]. Our results anticipate the arrival of ExoMars 2016's Schiaparelli module, which will provide the first records of electric field at the surface of the planet [Déprez et al., EGU GA, 16, 16613, 2014]. This research is also motived by the increasing probability of manned missions to Mars and the potential electrostatic hazards it may face [Yair, 2012], and by the role of electrical discharges in the creation of active radicals, some of which may be of biological importance [Miller, Science, 117, 528-529, 1953; Biochem. Biophys. Acta, 23, 480-489, 1957].

  12. Molten salt-directed synthesis method for LiMn2O4 nanorods as a cathode material for a lithium-ion battery with superior cyclability

    NASA Astrophysics Data System (ADS)

    Kebede, Mesfin A.; Ozoemena, Kenneth I.

    2017-02-01

    A molten salt synthesis technique has been used to prepare nanorods of Mn2O3 and single-crystal LiMn2O4 nanorods cathode material with superior capacity retention. The molten salt-directed synthesis involved the use of NaCl as the eutectic melt. The as-synthesized LiMn2O4 nanorods cathode material showed superior electrochemical performance compared to the LiMn2O4 sample obtained via the solid state method. The as-synthesized LiMn2O4 nanorods maintained more than 95% of the initial discharge capacity of 107 mA h g-1 over 100 cycles at a rate of 0.1 C, whereas the LiMn2O4 sample synthesized using the solid state reaction method maintained 88% of the initial discharge capacity of 98 mA h g-1 over 100 cycles at a rate of 0.1 C. Compared to the literature, the molten salt-directed method for the preparation of high-performance LiMn2O4 is simpler and less expensive, with greater potential for industrial scale-up.

  13. Silicon hollow sphere anode with enhanced cycling stability by a template-free method

    NASA Astrophysics Data System (ADS)

    Chen, Song; Chen, Zhuo; Luo, Yunjun; Xia, Min; Cao, Chuanbao

    2017-04-01

    Silicon is a promising alternative anode material since it has a ten times higher theoretical specific capacity than that of a traditional graphite anode. However, the poor cycling stability due to the huge volume change of Si during charge/discharge processes has seriously hampered its widespread application. To address this challenge, we design a silicon hollow sphere nanostructure by selective etching and a subsequent magnesiothermic reduction. The Si hollow spheres exhibit enhanced electrochemical properties compared to the commercial Si nanoparticles. The initial discharge and charge capacities of the Si hollow sphere anode are 2215.8 mAh g-1 and 1615.1 mAh g-1 with a high initial coulombic efficiency (72%) at a current density of 200 mA g-1, respectively. In particular, the reversible capacity is 1534.5 mAh g-1 with a remarkable 88% capacity retention against the second cycle after 100 cycles, over four times the theoretical capacity of the traditional graphite electrode. Therefore, our work demonstrates the considerable potential of silicon structures for displacing commercial graphite, and might open up new opportunities to rationally design various nanostructured materials for lithium ion batteries.

  14. Mechanism and computational model for Lyman-α-radiation generation by high-intensity-laser four-wave mixing in Kr-Ar gas

    NASA Astrophysics Data System (ADS)

    Louchev, Oleg A.; Bakule, Pavel; Saito, Norihito; Wada, Satoshi; Yokoyama, Koji; Ishida, Katsuhiko; Iwasaki, Masahiko

    2011-09-01

    We present a theoretical model combined with a computational study of a laser four-wave mixing process under optical discharge in which the non-steady-state four-wave amplitude equations are integrated with the kinetic equations of initial optical discharge and electron avalanche ionization in Kr-Ar gas. The model is validated by earlier experimental data showing strong inhibition of the generation of pulsed, tunable Lyman-α (Ly-α) radiation when using sum-difference frequency mixing of 212.6 nm and tunable infrared radiation (820-850 nm). The rigorous computational approach to the problem reveals the possibility and mechanism of strong auto-oscillations in sum-difference resonant Ly-α generation due to the combined effect of (i) 212.6-nm (2+1)-photon ionization producing initial electrons, followed by (ii) the electron avalanche dominated by 843-nm radiation, and (iii) the final breakdown of the phase matching condition. The model shows that the final efficiency of Ly-α radiation generation can achieve a value of ˜5×10-4 which is restricted by the total combined absorption of the fundamental and generated radiation.

  15. Multiple recurrent ischaemic strokes in a patient with cancer: is there a role for the initiation of anticoagulation therapy for secondary stroke prevention?

    PubMed

    Suero-Abreu, Giselle Alexandra; Cheng, Jia Zhen; Then, Ryna Karina

    2017-06-03

    A 52-year-old woman with a medical history of cervical and thyroid cancer, hypertension, dyslipidaemia, uncontrolled diabetes and heavy smoking was diagnosed with a new metastatic cholangiocarcinoma. While undergoing palliative chemotherapy, she developed dysarthria and left-sided weakness. Imaging studies showed multiple bilateral ischaemic strokes. On hospital days 2 and 5, she developed worsening neurological symptoms and imaging studies revealed new areas of ischaemia on respective days. Subsequent workup did not revealed a clear aetiology for the multiple ischaemic events and hypercoagulability studies were only significant for a mildly elevated serum D-dimer level. Although guidelines are unclear, full-dose anticoagulation with low molecular weight heparin was initiated given her high risk of stroke recurrence. She was discharged to acute rehabilitation but, within a month, she experienced complications of her malignant disease progression and a new pulmonary thromboembolism. The patient died soon after being discharged home with hospice care. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. The development of shock wave overpressure driven by channel expansion of high current impulse discharge arc

    NASA Astrophysics Data System (ADS)

    Xiong, Jia-ming; Li, Lee; Dai, Hong-yu; Wu, Hai-bo; Peng, Ming-yang; Lin, Fu-chang

    2018-03-01

    During the formation of a high current impulse discharge arc, objects near the discharge arc will be strongly impacted. In this paper, a high power, high current gas switch is used as the site of the impulse discharge arc. The explosion wave theory and the arc channel energy balance equation are introduced to analyze the development of the shock wave overpressure driven by the high current impulse discharge arc, and the demarcation point of the arc channel is given, from which the energy of the arc channel is no longer converted into shock waves. Through the analysis and calculation, it is found that the magnitude of the shock wave overpressure caused by impulse discharge arc expansion is closely related to the arc current rising rate. The arc shock wave overpressure will undergo a slow decay process and then decay rapidly. The study of this paper will perform the function of deepening the understanding of the physical nature of the impulse arc discharge, which can be used to explain the damage effect of the high current impulse discharge arc.

  17. Repeat neuroimaging of mild traumatic brain-injured patients with acute traumatic intracranial hemorrhage: clinical outcomes and radiographic features.

    PubMed

    Kreitzer, Natalie; Lyons, Michael S; Hart, Kim; Lindsell, Cristopher J; Chung, Sora; Yick, Andrew; Bonomo, Jordan

    2014-10-01

    Emergency department (ED) management of mild traumatic brain injury (TBI) patients with any form of traumatic intracranial hemorrhage (ICH) is variable. Since 2000, our center's standard practice has been to obtain a repeat head computed tomography (CT) at least 6 hours after initial imaging. Patients are eligible for discharge if clinical and CT findings are stable. Whether this practice is safe is unknown. This study characterized clinical outcomes in mild TBI patients with acute traumatic ICH seen on initial ED neuroimaging. This retrospective cohort study included patients presenting to the ED with blunt mild TBI with Glasgow Coma Scale (GCS) scores of 14 or 15 and stable vital signs, during the period from January 2001 to January 2010. Patients with any ICH on initial head CT and repeat head CT within 24 hours were eligible. Cases were excluded for initial GCS < 14, injury > 24 hours old, pregnancy, concomitant nonminor injuries, and coagulopathy. A single investigator abstracted data from records using a standardized case report form and data dictionary. Primary endpoints included death, neurosurgical procedures, and for discharged patients, return to the ED within 7 days. Differences in proportions were computed with 95% confidence intervals (CIs). Of 1,011 patients who presented to the ED and had two head CTs within 24 hours, 323 (32%) met inclusion criteria. The median time between CT scans was 6 hours (interquartile range = 5 to 7 hours). A total of 153 (47%) patients had subarachnoid hemorrhage, 132 (41%) patients had subdural hemorrhage, 11 (3%) patients had epidural hemorrhage, 78 (24%) patients had cerebral contusions, and 59 (18%) patients had intraparenchymal hemorrhage. Four of 323 (1.2%, 95% CI = 0.3% to 3.2%) patients died within 2 weeks of injury. Three of the patients who died had been admitted from the ED on their initial visits, and one had been discharged home. There were 206 patients (64%) discharged from the ED, 28 (13.6%) of whom returned to the ED within 1 week. Of the 92 who were hospitalized, three (0.9%, 95% CI = 0.2% to 2.7%) required neurosurgical intervention. Discharge after a repeat head CT and brief period of observation in the ED allowed early discharge of a cohort of mild TBI patients with traumatic ICH without delayed adverse outcomes. Whether this justifies the cost and radiation exposure involved with this pattern of practice requires further study. © 2014 by the Society for Academic Emergency Medicine.

  18. Lighting Observations During the Mt. Augustine Volcanic Eruptions With the Portable Lightning Mapping Stations

    NASA Astrophysics Data System (ADS)

    Rison, W.; Krehbiel, P.; Thomas, R.; Edens, H.; Aulich, G.; O'Connor, N.; Kieft, S.; McNutt, S.; Tytgat, G.; Clark, E.

    2006-12-01

    Following the initial eruptions of Mt. Augustine on January 11-17 2006, we quickly prepared and deployed a first contingent of two portable mapping stations. This was our first use of the newly-developed portable stations, and we were able to deploy them in time to observe the second set of explosive eruptions during the night of January~27-28. The stations were located 17~km apart on the west coast of the Kenai Peninsula, 100~km distant from Augustine on the far western side of Cook Inlet. The stations comprised a minimal network capable of determining the azimuthal direction of VHF radiation sources from electrical discharges, and thus the transverse location of the electrical activity relative to the volcano. The time series data from the southern, Homer station for the initial, energetic explosion at 8:31 pm on January~27 revealed the occurrence of spectacular lightning, which from the two-station data drifted southward from Augustine with time, in the same direction as the plume from the eruption. About 300 distinct lightning discharges occurred over an 11-minute time interval, beginning 2-3~min after the main explosion. The lightning quickly became increasingly complex with time and developed large horizontal extents. One of the final discharges of the sequence lasted 600~ms and had a transverse extent of 15~km, extending to 22~km south of Augustine's summit. In addition to this more usual form of lightning, continuous bursts of radio frequency radiation occurred during the explosion itself, indicating that the tephra was highly charged upon being ejected from the volcano. A completely unplanned and initially missed but one of several fortuitous aspects of the observations was that the Homer station functioned as a 'sea-surface interferometer' whose interference pattern can be used to determine the altitude variation with time for some discharges. The station's VHF antenna was located on the edge of a bluff 210~m above Cook Inlet and received both the direct and reflected signals from the water surface. A clear pattern of interference fringes was observed for the strongest lightning event during the explosive phase and has shown that it was an upward-triggered discharge that propagated upward from Augustine's summit and into the downwind plume. The radiation sources were characteristic of negative polarity breakdown into inferred positive charge in the plume. None of the lightning activity from the January~27-28 eruptions was observed visually due to stormy weather conditions.

  19. Investigation of the Discharge Characteristics of the T6 Hollow Cathode Operating on Several Inert Gases and a Kr/Xe Mixture

    NASA Astrophysics Data System (ADS)

    Ahmed Rudwan, M.; Gabriel, S. B.

    2002-01-01

    Investigation of the discharge characteristics of the T6 hollow cathode operating on several inert Xenon is currently the propellant of choice for gridded ion thrusters. But in order to make deep space missions feasible, an increase in the Specific Impulse (SI) that these thrusters can achieve is necessary. One method of achieving this is to use a propellant with a lower atomic mass (e.g. argon), as the propellant exhaust velocity is inversely proportional to the square root of the propellant mass. However, the feasibility of operating the hollow cathode using these alternative propellants has to be demonstrated. Moreover, interest in decreasing the propellant cost in missions and ground testing (especially life tests) have led to the comprehensive discharge characterisation of several gases that will be presented in this paper. A Kr/Xe mixture in the naturally occurring ratio, for example, could offer a 15 times cost saving when compared to pure xenon and 2-3 times cost saving when compared to pure krypton. The T6 hollow cathode discharge behaviour as well as its initiation characteristics have been studied. The tests were carried out in diode configuration using a T6 hollow cathode with an enclosed keeper design employing xenon, krypton, argon and a Kr/Xe mix. The discharge initiation tests were undertaken with a view to investigate some of the factors thought to influence the starting potential such as mass flow rate and tip temperature. It was found that, for mass flow rates ranging from 0.2-1.1 mg/s and cathode tip temperatures ranging from 900-1300oC, the breakdown potential was less than 50V for argon, less than 25V for krypton, less than 21V for xenon and less than 35V for the Kr/Xe mix. The discharge initiation results were then compared to those obtained by Fearn et al. with a T5 cathode operating on mercury and with a T6 cathode utilising an open keeper design using xenon propellant. The xenon breakdown potentials were found to be lower than those obtained with an open keeper design by as much as 4V. Steady state discharge behaviour was also investigated in a range of operating conditions. Spot to plume mode transitions were observed in argon, krypton and Kr/Xe discharges for the first time.

  20. High-speed imaging system for observation of discharge phenomena

    NASA Astrophysics Data System (ADS)

    Tanabe, R.; Kusano, H.; Ito, Y.

    2008-11-01

    A thin metal electrode tip instantly changes its shape into a sphere or a needlelike shape in a single electrical discharge of high current. These changes occur within several hundred microseconds. To observe these high-speed phenomena in a single discharge, an imaging system using a high-speed video camera and a high repetition rate pulse laser was constructed. A nanosecond laser, the wavelength of which was 532 nm, was used as the illuminating source of a newly developed high-speed video camera, HPV-1. The time resolution of our system was determined by the laser pulse width and was about 80 nanoseconds. The system can take one hundred pictures at 16- or 64-microsecond intervals in a single discharge event. A band-pass filter at 532 nm was placed in front of the camera to block the emission of the discharge arc at other wavelengths. Therefore, clear images of the electrode were recorded even during the discharge. If the laser was not used, only images of plasma during discharge and thermal radiation from the electrode after discharge were observed. These results demonstrate that the combination of a high repetition rate and a short pulse laser with a high speed video camera provides a unique and powerful method for high speed imaging.

Top