Sample records for high level vision

  1. Parallel Architectures and Parallel Algorithms for Integrated Vision Systems. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Choudhary, Alok Nidhi

    1989-01-01

    Computer vision is regarded as one of the most complex and computationally intensive problems. An integrated vision system (IVS) is a system that uses vision algorithms from all levels of processing to perform for a high level application (e.g., object recognition). An IVS normally involves algorithms from low level, intermediate level, and high level vision. Designing parallel architectures for vision systems is of tremendous interest to researchers. Several issues are addressed in parallel architectures and parallel algorithms for integrated vision systems.

  2. Implementing An Image Understanding System Architecture Using Pipe

    NASA Astrophysics Data System (ADS)

    Luck, Randall L.

    1988-03-01

    This paper will describe PIPE and how it can be used to implement an image understanding system. Image understanding is the process of developing a description of an image in order to make decisions about its contents. The tasks of image understanding are generally split into low level vision and high level vision. Low level vision is performed by PIPE -a high performance parallel processor with an architecture specifically designed for processing video images at up to 60 fields per second. High level vision is performed by one of several types of serial or parallel computers - depending on the application. An additional processor called ISMAP performs the conversion from iconic image space to symbolic feature space. ISMAP plugs into one of PIPE's slots and is memory mapped into the high level processor. Thus it forms the high speed link between the low and high level vision processors. The mechanisms for bottom-up, data driven processing and top-down, model driven processing are discussed.

  3. European starlings use their acute vision to check on feline predators but not on conspecifics

    PubMed Central

    Fernández-Juricic, Esteban

    2018-01-01

    Head movements allow birds with laterally placed eyes to move their centers of acute vision around and align them with objects of interest. Consequently, head movements have been used as indicator of fixation behavior (where gaze is maintained). However, studies on head movement behavior have not elucidated the degree to which birds use high-acuity or low-acuity vision. We studied how European starlings (Sturnus vulgaris) used high-acuity vision in the early stages of visual exploration of a stuffed cat (common terrestrial predator), a taxidermy Cooper’s hawk (common aerial predator), and a stuffed study skin of a conspecific. We found that starlings tended to use their high acuity vision when looking at predators, particularly, the cat was above chance levels. However, when they viewed a conspecific, they used high acuity vision as expected by chance. We did not observe a preference for the left or right center of acute vision. Our findings suggest that starlings exposed to a predator (particularly cats) may employ selective attention by using high-acuity vision to obtain quickly detailed information useful for a potential escape, but exposed to a social context may use divided attention by allocating similar levels high- and low-quality vision to monitor both conspecifics and the rest of the environment. PMID:29370164

  4. Dynamic programming and graph algorithms in computer vision.

    PubMed

    Felzenszwalb, Pedro F; Zabih, Ramin

    2011-04-01

    Optimization is a powerful paradigm for expressing and solving problems in a wide range of areas, and has been successfully applied to many vision problems. Discrete optimization techniques are especially interesting since, by carefully exploiting problem structure, they often provide nontrivial guarantees concerning solution quality. In this paper, we review dynamic programming and graph algorithms, and discuss representative examples of how these discrete optimization techniques have been applied to some classical vision problems. We focus on the low-level vision problem of stereo, the mid-level problem of interactive object segmentation, and the high-level problem of model-based recognition.

  5. Visual cognition

    PubMed Central

    Cavanagh, Patrick

    2011-01-01

    Visual cognition, high-level vision, mid-level vision and top-down processing all refer to decision-based scene analyses that combine prior knowledge with retinal input to generate representations. The label “visual cognition” is little used at present, but research and experiments on mid- and high-level, inference-based vision have flourished, becoming in the 21st century a significant, if often understated part, of current vision research. How does visual cognition work? What are its moving parts? This paper reviews the origins and architecture of visual cognition and briefly describes some work in the areas of routines, attention, surfaces, objects, and events (motion, causality, and agency). Most vision scientists avoid being too explicit when presenting concepts about visual cognition, having learned that explicit models invite easy criticism. What we see in the literature is ample evidence for visual cognition, but few or only cautious attempts to detail how it might work. This is the great unfinished business of vision research: at some point we will be done with characterizing how the visual system measures the world and we will have to return to the question of how vision constructs models of objects, surfaces, scenes, and events. PMID:21329719

  6. Dynamic Programming and Graph Algorithms in Computer Vision*

    PubMed Central

    Felzenszwalb, Pedro F.; Zabih, Ramin

    2013-01-01

    Optimization is a powerful paradigm for expressing and solving problems in a wide range of areas, and has been successfully applied to many vision problems. Discrete optimization techniques are especially interesting, since by carefully exploiting problem structure they often provide non-trivial guarantees concerning solution quality. In this paper we briefly review dynamic programming and graph algorithms, and discuss representative examples of how these discrete optimization techniques have been applied to some classical vision problems. We focus on the low-level vision problem of stereo; the mid-level problem of interactive object segmentation; and the high-level problem of model-based recognition. PMID:20660950

  7. Automatic rule generation for high-level vision

    NASA Technical Reports Server (NTRS)

    Rhee, Frank Chung-Hoon; Krishnapuram, Raghu

    1992-01-01

    Many high-level vision systems use rule-based approaches to solving problems such as autonomous navigation and image understanding. The rules are usually elaborated by experts. However, this procedure may be rather tedious. In this paper, we propose a method to generate such rules automatically from training data. The proposed method is also capable of filtering out irrelevant features and criteria from the rules.

  8. Do we understand high-level vision?

    PubMed

    Cox, David Daniel

    2014-04-01

    'High-level' vision lacks a single, agreed upon definition, but it might usefully be defined as those stages of visual processing that transition from analyzing local image structure to analyzing structure of the external world that produced those images. Much work in the last several decades has focused on object recognition as a framing problem for the study of high-level visual cortex, and much progress has been made in this direction. This approach presumes that the operational goal of the visual system is to read-out the identity of an object (or objects) in a scene, in spite of variation in the position, size, lighting and the presence of other nearby objects. However, while object recognition as a operational framing of high-level is intuitive appealing, it is by no means the only task that visual cortex might do, and the study of object recognition is beset by challenges in building stimulus sets that adequately sample the infinite space of possible stimuli. Here I review the successes and limitations of this work, and ask whether we should reframe our approaches to understanding high-level vision. Copyright © 2014. Published by Elsevier Ltd.

  9. Bio-inspired approach for intelligent unattended ground sensors

    NASA Astrophysics Data System (ADS)

    Hueber, Nicolas; Raymond, Pierre; Hennequin, Christophe; Pichler, Alexander; Perrot, Maxime; Voisin, Philippe; Moeglin, Jean-Pierre

    2015-05-01

    Improving the surveillance capacity over wide zones requires a set of smart battery-powered Unattended Ground Sensors capable of issuing an alarm to a decision-making center. Only high-level information has to be sent when a relevant suspicious situation occurs. In this paper we propose an innovative bio-inspired approach that mimics the human bi-modal vision mechanism and the parallel processing ability of the human brain. The designed prototype exploits two levels of analysis: a low-level panoramic motion analysis, the peripheral vision, and a high-level event-focused analysis, the foveal vision. By tracking moving objects and fusing multiple criteria (size, speed, trajectory, etc.), the peripheral vision module acts as a fast relevant event detector. The foveal vision module focuses on the detected events to extract more detailed features (texture, color, shape, etc.) in order to improve the recognition efficiency. The implemented recognition core is able to acquire human knowledge and to classify in real-time a huge amount of heterogeneous data thanks to its natively parallel hardware structure. This UGS prototype validates our system approach under laboratory tests. The peripheral analysis module demonstrates a low false alarm rate whereas the foveal vision correctly focuses on the detected events. A parallel FPGA implementation of the recognition core succeeds in fulfilling the embedded application requirements. These results are paving the way of future reconfigurable virtual field agents. By locally processing the data and sending only high-level information, their energy requirements and electromagnetic signature are optimized. Moreover, the embedded Artificial Intelligence core enables these bio-inspired systems to recognize and learn new significant events. By duplicating human expertise in potentially hazardous places, our miniature visual event detector will allow early warning and contribute to better human decision making.

  10. Translating Vision into Design: A Method for Conceptual Design Development

    NASA Technical Reports Server (NTRS)

    Carpenter, Joyce E.

    2003-01-01

    One of the most challenging tasks for engineers is the definition of design solutions that will satisfy high-level strategic visions and objectives. Even more challenging is the need to demonstrate how a particular design solution supports the high-level vision. This paper describes a process and set of system engineering tools that have been used at the Johnson Space Center to analyze and decompose high-level objectives for future human missions into design requirements that can be used to develop alternative concepts for vehicles, habitats, and other systems. Analysis and design studies of alternative concepts and approaches are used to develop recommendations for strategic investments in research and technology that support the NASA Integrated Space Plan. In addition to a description of system engineering tools, this paper includes a discussion of collaborative design practices for human exploration mission architecture studies used at the Johnson Space Center.

  11. Face adaptation improves gender discrimination.

    PubMed

    Yang, Hua; Shen, Jianhong; Chen, Juan; Fang, Fang

    2011-01-01

    Adaptation to a visual pattern can alter the sensitivities of neuronal populations encoding the pattern. However, the functional roles of adaptation, especially in high-level vision, are still equivocal. In the present study, we performed three experiments to investigate if face gender adaptation could affect gender discrimination. Experiments 1 and 2 revealed that adapting to a male/female face could selectively enhance discrimination for male/female faces. Experiment 3 showed that the discrimination enhancement induced by face adaptation could transfer across a substantial change in three-dimensional face viewpoint. These results provide further evidence suggesting that, similar to low-level vision, adaptation in high-level vision could calibrate the visual system to current inputs of complex shapes (i.e. face) and improve discrimination at the adapted characteristic. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Color image processing and vision system for an automated laser paint-stripping system

    NASA Astrophysics Data System (ADS)

    Hickey, John M., III; Hise, Lawson

    1994-10-01

    Color image processing in machine vision systems has not gained general acceptance. Most machine vision systems use images that are shades of gray. The Laser Automated Decoating System (LADS) required a vision system which could discriminate between substrates of various colors and textures and paints ranging from semi-gloss grays to high gloss red, white and blue (Air Force Thunderbirds). The changing lighting levels produced by the pulsed CO2 laser mandated a vision system that did not require a constant color temperature lighting for reliable image analysis.

  13. Promoting vision and hearing aids use in an intensive care unit.

    PubMed

    Zhou, Qiaoling; Faure Walker, Nicholas

    2015-01-01

    Vision and hearing impairments have long been recognised as modifiable risk factors for delirium.[1,2,3] Delirium in critically ill patients is a frequent complication (reported as high as 60% to 80% of intensive care patients), and is associated with a three-fold increase in mortality and prolonged hospital stay.[1] Guidelines by the UK Clinical Pharmacy Association recommend minimising risk factors to prevent delirium, rather than to treat it with pharmacological agents which may themselves cause delirium.[4] To address risk factors is a measure of multi-system management, such as sleep-wake cycle correction, orientation and use of vision and hearing aids, etc.[5] We designed an audit to survey the prevalence and availability of vision and hearing aids use in the intensive care unit (ICU) of one university hospital. The baseline data demonstrated a high level of prevalence and low level of availability of vision /hearing aid use. We implemented changes to the ICU Innovian assessment system, which serves to remind nursing staff performing daily checks on delirium reduction measures. This has improved practice in promoting vision and hearing aids use in ICU as shown by re-audit at six month. Further amendments to the Innovian risk assessments have increased the rate of assessment to 100% and vision aid use to near 100%.

  14. Recent advances in the development and transfer of machine vision technologies for space

    NASA Technical Reports Server (NTRS)

    Defigueiredo, Rui J. P.; Pendleton, Thomas

    1991-01-01

    Recent work concerned with real-time machine vision is briefly reviewed. This work includes methodologies and techniques for optimal illumination, shape-from-shading of general (non-Lambertian) 3D surfaces, laser vision devices and technology, high level vision, sensor fusion, real-time computing, artificial neural network design and use, and motion estimation. Two new methods that are currently being developed for object recognition in clutter and for 3D attitude tracking based on line correspondence are discussed.

  15. Image understanding systems based on the unifying representation of perceptual and conceptual information and the solution of mid-level and high-level vision problems

    NASA Astrophysics Data System (ADS)

    Kuvychko, Igor

    2001-10-01

    Vision is a part of a larger information system that converts visual information into knowledge structures. These structures drive vision process, resolving ambiguity and uncertainty via feedback, and provide image understanding, that is an interpretation of visual information in terms of such knowledge models. A computer vision system based on such principles requires unifying representation of perceptual and conceptual information. Computer simulation models are built on the basis of graphs/networks. The ability of human brain to emulate similar graph/networks models is found. That means a very important shift of paradigm in our knowledge about brain from neural networks to the cortical software. Starting from the primary visual areas, brain analyzes an image as a graph-type spatial structure. Primary areas provide active fusion of image features on a spatial grid-like structure, where nodes are cortical columns. The spatial combination of different neighbor features cannot be described as a statistical/integral characteristic of the analyzed region, but uniquely characterizes such region itself. Spatial logic and topology naturally present in such structures. Mid-level vision processes like clustering, perceptual grouping, multilevel hierarchical compression, separation of figure from ground, etc. are special kinds of graph/network transformations. They convert low-level image structure into the set of more abstract ones, which represent objects and visual scene, making them easy for analysis by higher-level knowledge structures. Higher-level vision phenomena like shape from shading, occlusion, etc. are results of such analysis. Such approach gives opportunity not only to explain frequently unexplainable results of the cognitive science, but also to create intelligent computer vision systems that simulate perceptional processes in both what and where visual pathways. Such systems can open new horizons for robotic and computer vision industries.

  16. A study on low-cost, high-accuracy, and real-time stereo vision algorithms for UAV power line inspection

    NASA Astrophysics Data System (ADS)

    Wang, Hongyu; Zhang, Baomin; Zhao, Xun; Li, Cong; Lu, Cunyue

    2018-04-01

    Conventional stereo vision algorithms suffer from high levels of hardware resource utilization due to algorithm complexity, or poor levels of accuracy caused by inadequacies in the matching algorithm. To address these issues, we have proposed a stereo range-finding technique that produces an excellent balance between cost, matching accuracy and real-time performance, for power line inspection using UAV. This was achieved through the introduction of a special image preprocessing algorithm and a weighted local stereo matching algorithm, as well as the design of a corresponding hardware architecture. Stereo vision systems based on this technique have a lower level of resource usage and also a higher level of matching accuracy following hardware acceleration. To validate the effectiveness of our technique, a stereo vision system based on our improved algorithms were implemented using the Spartan 6 FPGA. In comparative experiments, it was shown that the system using the improved algorithms outperformed the system based on the unimproved algorithms, in terms of resource utilization and matching accuracy. In particular, Block RAM usage was reduced by 19%, and the improved system was also able to output range-finding data in real time.

  17. A summary of image segmentation techniques

    NASA Technical Reports Server (NTRS)

    Spirkovska, Lilly

    1993-01-01

    Machine vision systems are often considered to be composed of two subsystems: low-level vision and high-level vision. Low level vision consists primarily of image processing operations performed on the input image to produce another image with more favorable characteristics. These operations may yield images with reduced noise or cause certain features of the image to be emphasized (such as edges). High-level vision includes object recognition and, at the highest level, scene interpretation. The bridge between these two subsystems is the segmentation system. Through segmentation, the enhanced input image is mapped into a description involving regions with common features which can be used by the higher level vision tasks. There is no theory on image segmentation. Instead, image segmentation techniques are basically ad hoc and differ mostly in the way they emphasize one or more of the desired properties of an ideal segmenter and in the way they balance and compromise one desired property against another. These techniques can be categorized in a number of different groups including local vs. global, parallel vs. sequential, contextual vs. noncontextual, interactive vs. automatic. In this paper, we categorize the schemes into three main groups: pixel-based, edge-based, and region-based. Pixel-based segmentation schemes classify pixels based solely on their gray levels. Edge-based schemes first detect local discontinuities (edges) and then use that information to separate the image into regions. Finally, region-based schemes start with a seed pixel (or group of pixels) and then grow or split the seed until the original image is composed of only homogeneous regions. Because there are a number of survey papers available, we will not discuss all segmentation schemes. Rather than a survey, we take the approach of a detailed overview. We focus only on the more common approaches in order to give the reader a flavor for the variety of techniques available yet present enough details to facilitate implementation and experimentation.

  18. Reading with filtered fixations: adult age differences in the effectiveness of low-level properties of text within central vision.

    PubMed

    Jordan, Timothy R; McGowan, Victoria A; Paterson, Kevin B

    2014-06-01

    When reading, low-level visual properties of text are acquired from central vision during brief fixational pauses, but the effectiveness of these properties may differ in older age. To investigate, a filtering technique displayed the low, medium, or high spatial frequencies of text falling within central vision as young (18-28 years) and older (65+ years) adults read. Reading times for normal text did not differ across age groups, but striking differences in the effectiveness of spatial frequencies were observed. Consequently, even when young and older adults read equally well, the effectiveness of spatial frequencies in central vision differs markedly in older age. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  19. Vision in high-level football officials.

    PubMed

    Baptista, António Manuel Gonçalves; Serra, Pedro M; McAlinden, Colm; Barrett, Brendan T

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23.9% wear contact lenses when officiating. Clinical vision measures in the football officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual acuity may be improved in around a quarter of officials.

  20. Vision in high-level football officials

    PubMed Central

    Serra, Pedro M.; McAlinden, Colm; Barrett, Brendan T.

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23.9% wear contact lenses when officiating. Clinical vision measures in the football officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual acuity may be improved in around a quarter of officials. PMID:29161310

  1. Deep Neural Networks: A New Framework for Modeling Biological Vision and Brain Information Processing.

    PubMed

    Kriegeskorte, Nikolaus

    2015-11-24

    Recent advances in neural network modeling have enabled major strides in computer vision and other artificial intelligence applications. Human-level visual recognition abilities are coming within reach of artificial systems. Artificial neural networks are inspired by the brain, and their computations could be implemented in biological neurons. Convolutional feedforward networks, which now dominate computer vision, take further inspiration from the architecture of the primate visual hierarchy. However, the current models are designed with engineering goals, not to model brain computations. Nevertheless, initial studies comparing internal representations between these models and primate brains find surprisingly similar representational spaces. With human-level performance no longer out of reach, we are entering an exciting new era, in which we will be able to build biologically faithful feedforward and recurrent computational models of how biological brains perform high-level feats of intelligence, including vision.

  2. Machine vision and appearance based learning

    NASA Astrophysics Data System (ADS)

    Bernstein, Alexander

    2017-03-01

    Smart algorithms are used in Machine vision to organize or extract high-level information from the available data. The resulted high-level understanding the content of images received from certain visual sensing system and belonged to an appearance space can be only a key first step in solving various specific tasks such as mobile robot navigation in uncertain environments, road detection in autonomous driving systems, etc. Appearance-based learning has become very popular in the field of machine vision. In general, the appearance of a scene is a function of the scene content, the lighting conditions, and the camera position. Mobile robots localization problem in machine learning framework via appearance space analysis is considered. This problem is reduced to certain regression on an appearance manifold problem, and newly regression on manifolds methods are used for its solution.

  3. Review On Applications Of Neural Network To Computer Vision

    NASA Astrophysics Data System (ADS)

    Li, Wei; Nasrabadi, Nasser M.

    1989-03-01

    Neural network models have many potential applications to computer vision due to their parallel structures, learnability, implicit representation of domain knowledge, fault tolerance, and ability of handling statistical data. This paper demonstrates the basic principles, typical models and their applications in this field. Variety of neural models, such as associative memory, multilayer back-propagation perceptron, self-stabilized adaptive resonance network, hierarchical structured neocognitron, high order correlator, network with gating control and other models, can be applied to visual signal recognition, reinforcement, recall, stereo vision, motion, object tracking and other vision processes. Most of the algorithms have been simulated on com-puters. Some have been implemented with special hardware. Some systems use features, such as edges and profiles, of images as the data form for input. Other systems use raw data as input signals to the networks. We will present some novel ideas contained in these approaches and provide a comparison of these methods. Some unsolved problems are mentioned, such as extracting the intrinsic properties of the input information, integrating those low level functions to a high-level cognitive system, achieving invariances and other problems. Perspectives of applications of some human vision models and neural network models are analyzed.

  4. Evaluation of an organic light-emitting diode display for precise visual stimulation.

    PubMed

    Ito, Hiroyuki; Ogawa, Masaki; Sunaga, Shoji

    2013-06-11

    A new type of visual display for presentation of a visual stimulus with high quality was assessed. The characteristics of an organic light-emitting diode (OLED) display (Sony PVM-2541, 24.5 in.; Sony Corporation, Tokyo, Japan) were measured in detail from the viewpoint of its applicability to visual psychophysics. We found the new display to be superior to other display types in terms of spatial uniformity, color gamut, and contrast ratio. Changes in the intensity of luminance were sharper on the OLED display than those on a liquid crystal display. Therefore, such OLED displays could replace conventional cathode ray tube displays in vision research for high quality stimulus presentation. Benefits of using OLED displays in vision research were especially apparent in the fields of low-level vision, where precise control and description of the stimulus are needed, e.g., in mesopic or scotopic vision, color vision, and motion perception.

  5. Coping strategies to manage stress related to vision loss and fluctuations in retinitis pigmentosa

    PubMed Central

    Bittner, Ava K.; Edwards, Lori; George, Maureen

    2010-01-01

    Background Vision loss in retinitis pigmentosa (RP) is a slowly progressive and inexorable threat to patients’ independence. It is not surprising that RP patients, many of whom are young when diagnosed, are at high risk for stress related to their vision loss. To address these issues, eye care providers need to be aware of what coping strategies RP patients use to successfully manage their vision loss. Methods We held focus groups with eight legally blind RP patients to help us better understand how they cope with the stress that is generated from their progressive vision loss and fluctuations in vision. Focus group sessions were audiotaped and resulting notes were coded using conventional qualitative analytic techniques. Results Two themes were identified: 1) “kicking and screaming” captured the ways in which RP patients fight to maintain their independence in the face of worsening vision; and 2) “there are so many worse things” describes how RP patients keep their vision loss in perspective. These RP patients demonstrated high levels of resiliency. In particular, they often used humor as a coping mechanism. Conclusions Understanding the ways in which RP patients manage their gradual, impending vision loss may lead to improved quality of care for this patient population. PMID:20591747

  6. Active vision in satellite scene analysis

    NASA Technical Reports Server (NTRS)

    Naillon, Martine

    1994-01-01

    In earth observation or planetary exploration it is necessary to have more and, more autonomous systems, able to adapt to unpredictable situations. This imposes the use, in artificial systems, of new concepts in cognition, based on the fact that perception should not be separated from recognition and decision making levels. This means that low level signal processing (perception level) should interact with symbolic and high level processing (decision level). This paper is going to describe the new concept of active vision, implemented in Distributed Artificial Intelligence by Dassault Aviation following a 'structuralist' principle. An application to spatial image interpretation is given, oriented toward flexible robotics.

  7. A High-Speed Vision-Based Sensor for Dynamic Vibration Analysis Using Fast Motion Extraction Algorithms.

    PubMed

    Zhang, Dashan; Guo, Jie; Lei, Xiujun; Zhu, Changan

    2016-04-22

    The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD) sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.

  8. Simulated Prosthetic Vision: The Benefits of Computer-Based Object Recognition and Localization.

    PubMed

    Macé, Marc J-M; Guivarch, Valérian; Denis, Grégoire; Jouffrais, Christophe

    2015-07-01

    Clinical trials with blind patients implanted with a visual neuroprosthesis showed that even the simplest tasks were difficult to perform with the limited vision restored with current implants. Simulated prosthetic vision (SPV) is a powerful tool to investigate the putative functions of the upcoming generations of visual neuroprostheses. Recent studies based on SPV showed that several generations of implants will be required before usable vision is restored. However, none of these studies relied on advanced image processing. High-level image processing could significantly reduce the amount of information required to perform visual tasks and help restore visuomotor behaviors, even with current low-resolution implants. In this study, we simulated a prosthetic vision device based on object localization in the scene. We evaluated the usability of this device for object recognition, localization, and reaching. We showed that a very low number of electrodes (e.g., nine) are sufficient to restore visually guided reaching movements with fair timing (10 s) and high accuracy. In addition, performance, both in terms of accuracy and speed, was comparable with 9 and 100 electrodes. Extraction of high level information (object recognition and localization) from video images could drastically enhance the usability of current visual neuroprosthesis. We suggest that this method-that is, localization of targets of interest in the scene-may restore various visuomotor behaviors. This method could prove functional on current low-resolution implants. The main limitation resides in the reliability of the vision algorithms, which are improving rapidly. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. The use of contact lenses in low vision rehabilitation: optical and therapeutic applications.

    PubMed

    Vincent, Stephen J

    2017-09-01

    Ocular pathology that manifests at an early age has the potential to alter the vision-dependent emmetropisation mechanism, which co-ordinates ocular growth throughout childhood. The disruption of this feedback mechanism in children with congenital or early-onset visual impairment often results in the development of significant ametropia, including high levels of spherical refractive error, astigmatism and anisometropia. This review examines the use of contact lenses as a refractive correction, low vision aid and therapeutic intervention in the rehabilitation of patients with bilateral, irreversible visual loss due to congenital ocular disease. The advantages and disadvantages of the use of contact lenses for increased magnification (telescopes and microscopes) or field expansion (reverse telescopes) are discussed, along with the benefits and practical considerations for the correction of pathological high myopia. The historical and present use of therapeutic tinted contact lenses to reduce photosensitivity and nystagmus in achromatopsia, albinism and aniridia are also presented, including clinical considerations for the contact lens practitioner. In addition to the known optical benefits in comparison to spectacles for high levels of ametropia (an improved field of view for myopes and fewer inherent oblique aberrations), contact lenses may be of significant psycho-social benefit for patients with low vision, due to enhanced cosmesis and reduced conspicuity and potential related effects of improved self-esteem and peer acceptance. The contact lens correction of patients with congenital vision impairment can be challenging for both practitioner and patient but should be considered as a potential optical or therapeutic solution in modern low vision rehabilitation. © 2017 Optometry Australia.

  10. Exemplary Science in Grades 9-12: Standards-Based Success Stories

    ERIC Educational Resources Information Center

    Yager, Robert E., Ed

    2005-01-01

    In this collection of 15 essays, educators describe successful programs they've developed to fulfill the National Science Education Standards' vision for the reform of teaching, assessment, professional development, and content at the high school level. All the visions correspond with the Less Emphasis and More Emphasis conditions that conclude…

  11. Vision Sensor-Based Road Detection for Field Robot Navigation

    PubMed Central

    Lu, Keyu; Li, Jian; An, Xiangjing; He, Hangen

    2015-01-01

    Road detection is an essential component of field robot navigation systems. Vision sensors play an important role in road detection for their great potential in environmental perception. In this paper, we propose a hierarchical vision sensor-based method for robust road detection in challenging road scenes. More specifically, for a given road image captured by an on-board vision sensor, we introduce a multiple population genetic algorithm (MPGA)-based approach for efficient road vanishing point detection. Superpixel-level seeds are then selected in an unsupervised way using a clustering strategy. Then, according to the GrowCut framework, the seeds proliferate and iteratively try to occupy their neighbors. After convergence, the initial road segment is obtained. Finally, in order to achieve a globally-consistent road segment, the initial road segment is refined using the conditional random field (CRF) framework, which integrates high-level information into road detection. We perform several experiments to evaluate the common performance, scale sensitivity and noise sensitivity of the proposed method. The experimental results demonstrate that the proposed method exhibits high robustness compared to the state of the art. PMID:26610514

  12. Development of a vision-targeted health-related quality of life item measure

    PubMed Central

    Slotkin, Jerry; McKean-Cowdin, Roberta; Lee, Paul; Owsley, Cynthia; Vitale, Susan; Varma, Rohit; Gershon, Richard; Hays, Ron D.

    2013-01-01

    Purpose To develop a vision-targeted health-related quality of life (HRQOL) measure for the NIH Toolbox for the Assessment of Neurological and Behavioral Function. Methods We conducted a review of existing vision-targeted HRQOL surveys and identified color vision, low luminance vision, distance vision, general vision, near vision, ocular symptoms, psychosocial well-being, and role performance domains. Items in existing survey instruments were sorted into these domains. We selected non-redundant items and revised them to improve clarity and to limit the number of different response options. We conducted 10 cognitive interviews to evaluate the items. Finally, we revised the items and administered them to 819 individuals to calibrate the items and estimate the measure’s reliability and validity. Results The field test provided support for the 53-item vision-targeted HRQOL measure encompassing 6 domains: color vision, distance vision, near vision, ocular symptoms, psychosocial well-being, and role performance. The domain scores had high levels of reliability (coefficient alphas ranged from 0.848 to 0.940). Validity was supported by high correlations between National Eye Institute Visual Function Questionnaire scales and the new-vision-targeted scales (highest values were 0.771 between psychosocial well-being and mental health, and 0.729 between role performance and role difficulties), and by lower mean scores in those groups self-reporting eye disease (F statistic with p < 0.01 for all comparisons except cataract with ocular symptoms, psychosocial well-being, and role performance scales). Conclusions This vision-targeted HRQOL measure provides a basis for comprehensive assessment of the impact of eye diseases and treatments on daily functioning and well-being in adults. PMID:23475688

  13. Color line scan camera technology and machine vision: requirements to consider

    NASA Astrophysics Data System (ADS)

    Paernaenen, Pekka H. T.

    1997-08-01

    Color machine vision has shown a dynamic uptrend in use within the past few years as the introduction of new cameras and scanner technologies itself underscores. In the future, the movement from monochrome imaging to color will hasten, as machine vision system users demand more knowledge about their product stream. As color has come to the machine vision, certain requirements for the equipment used to digitize color images are needed. Color machine vision needs not only a good color separation but also a high dynamic range and a good linear response from the camera used. Good dynamic range and linear response is necessary for color machine vision. The importance of these features becomes even more important when the image is converted to another color space. There is always lost some information when converting integer data to another form. Traditionally the color image processing has been much slower technique than the gray level image processing due to the three times greater data amount per image. The same has applied for the three times more memory needed. The advancements in computers, memory and processing units has made it possible to handle even large color images today cost efficiently. In some cases he image analysis in color images can in fact even be easier and faster than with a similar gray level image because of more information per pixel. Color machine vision sets new requirements for lighting, too. High intensity and white color light is required in order to acquire good images for further image processing or analysis. New development in lighting technology is bringing eventually solutions for color imaging.

  14. Synthetic vision display evaluation studies

    NASA Technical Reports Server (NTRS)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  15. AN INVESTIGATION OF VISION PROBLEMS AND THE VISION CARE SYSTEM IN RURAL CHINA.

    PubMed

    Bai, Yunli; Yi, Hongmei; Zhang, Linxiu; Shi, Yaojiang; Ma, Xiaochen; Congdon, Nathan; Zhou, Zhongqiang; Boswell, Matthew; Rozelle, Scott

    2014-11-01

    This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.

  16. Conscious Vision Proceeds from Global to Local Content in Goal-Directed Tasks and Spontaneous Vision.

    PubMed

    Campana, Florence; Rebollo, Ignacio; Urai, Anne; Wyart, Valentin; Tallon-Baudry, Catherine

    2016-05-11

    The reverse hierarchy theory (Hochstein and Ahissar, 2002) makes strong, but so far untested, predictions on conscious vision. In this theory, local details encoded in lower-order visual areas are unconsciously processed before being automatically and rapidly combined into global information in higher-order visual areas, where conscious percepts emerge. Contingent on current goals, local details can afterward be consciously retrieved. This model therefore predicts that (1) global information is perceived faster than local details, (2) global information is computed regardless of task demands during early visual processing, and (3) spontaneous vision is dominated by global percepts. We designed novel textured stimuli that are, as opposed to the classic Navon's letters, truly hierarchical (i.e., where global information is solely defined by local information but where local and global orientations can still be manipulated separately). In line with the predictions, observers were systematically faster reporting global than local properties of those stimuli. Second, global information could be decoded from magneto-encephalographic data during early visual processing regardless of task demands. Last, spontaneous subjective reports were dominated by global information and the frequency and speed of spontaneous global perception correlated with the accuracy and speed in the global task. No such correlation was observed for local information. We therefore show that information at different levels of the visual hierarchy is not equally likely to become conscious; rather, conscious percepts emerge preferentially at a global level. We further show that spontaneous reports can be reliable and are tightly linked to objective performance at the global level. Is information encoded at different levels of the visual system (local details in low-level areas vs global shapes in high-level areas) equally likely to become conscious? We designed new hierarchical stimuli and provide the first empirical evidence based on behavioral and MEG data that global information encoded at high levels of the visual hierarchy dominates perception. This result held both in the presence and in the absence of task demands. The preferential emergence of percepts at high levels can account for two properties of conscious vision, namely, the dominance of global percepts and the feeling of visual richness reported independently of the perception of local details. Copyright © 2016 the authors 0270-6474/16/365200-14$15.00/0.

  17. Region based route planning - Multi-abstraction route planning based on intermediate level vision processing

    NASA Technical Reports Server (NTRS)

    Doshi, Rajkumar S.; Lam, Raymond; White, James E.

    1989-01-01

    Intermediate and high level processing operations are performed on vision data for the organization of images into more meaningful, higher-level topological representations by means of a region-based route planner (RBRP). The RBRP operates in terrain scenarios where some or most of the terrain is occluded, proceeding without a priori maps on the basis of two-dimensional representations and gradient-and-roughness information. Route planning is accomplished by three successive abstractions and yields a detailed point-by-point path by searching only within the boundaries of relatively small regions.

  18. Guidelines on Diabetic Eye Care: The International Council of Ophthalmology Recommendations for Screening, Follow-up, Referral, and Treatment Based on Resource Settings.

    PubMed

    Wong, Tien Y; Sun, Jennifer; Kawasaki, Ryo; Ruamviboonsuk, Paisan; Gupta, Neeru; Lansingh, Van Charles; Maia, Mauricio; Mathenge, Wanjiku; Moreker, Sunil; Muqit, Mahi M K; Resnikoff, Serge; Verdaguer, Juan; Zhao, Peiquan; Ferris, Frederick; Aiello, Lloyd P; Taylor, Hugh R

    2018-05-24

    Diabetes mellitus (DM) is a global epidemic and affects populations in both developing and developed countries, with differing health care and resource levels. Diabetic retinopathy (DR) is a major complication of DM and a leading cause of vision loss in working middle-aged adults. Vision loss from DR can be prevented with broad-level public health strategies, but these need to be tailored to a country's and population's resource setting. Designing DR screening programs, with appropriate and timely referral to facilities with trained eye care professionals, and using cost-effective treatment for vision-threatening levels of DR can prevent vision loss. The International Council of Ophthalmology Guidelines for Diabetic Eye Care 2017 summarize and offer a comprehensive guide for DR screening, referral and follow-up schedules for DR, and appropriate management of vision-threatening DR, including diabetic macular edema (DME) and proliferative DR, for countries with high- and low- or intermediate-resource settings. The guidelines include updated evidence on screening and referral criteria, the minimum requirements for a screening vision and retinal examination, follow-up care, and management of DR and DME, including laser photocoagulation and appropriate use of intravitreal anti-vascular endothelial growth factor inhibitors and, in specific situations, intravitreal corticosteroids. Recommendations for management of DR in patients during pregnancy and with concomitant cataract also are included. The guidelines offer suggestions for monitoring outcomes and indicators of success at a population level. Copyright © 2018 American Academy of Ophthalmology. All rights reserved.

  19. Neuromorphic vision sensors and preprocessors in system applications

    NASA Astrophysics Data System (ADS)

    Kramer, Joerg; Indiveri, Giacomo

    1998-09-01

    A partial review of neuromorphic vision sensors that are suitable for use in autonomous systems is presented. Interfaces are being developed to multiplex the high- dimensional output signals of arrays of such sensors and to communicate them in standard formats to off-chip devices for higher-level processing, actuation, storage and display. Alternatively, on-chip processing stages may be implemented to extract sparse image parameters, thereby obviating the need for multiplexing. Autonomous robots are used to test neuromorphic vision chips in real-world environments and to explore the possibilities of data fusion from different sensing modalities. Examples of autonomous mobile systems that use neuromorphic vision chips for line tracking and optical flow matching are described.

  20. Emotion improves and impairs early vision.

    PubMed

    Bocanegra, Bruno R; Zeelenberg, René

    2009-06-01

    Recent studies indicate that emotion enhances early vision, but the generality of this finding remains unknown. Do the benefits of emotion extend to all basic aspects of vision, or are they limited in scope? Our results show that the brief presentation of a fearful face, compared with a neutral face, enhances sensitivity for the orientation of subsequently presented low-spatial-frequency stimuli, but diminishes orientation sensitivity for high-spatial-frequency stimuli. This is the first demonstration that emotion not only improves but also impairs low-level vision. The selective low-spatial-frequency benefits are consistent with the idea that emotion enhances magnocellular processing. Additionally, we suggest that the high-spatial-frequency deficits are due to inhibitory interactions between magnocellular and parvocellular pathways. Our results suggest an emotion-induced trade-off in visual processing, rather than a general improvement. This trade-off may benefit perceptual dimensions that are relevant for survival at the expense of those that are less relevant.

  1. A Personal Statement about a Four-Year Curriculum for Heritage and Native Speakers of Spanish Programs.

    ERIC Educational Resources Information Center

    Stering, Edward

    This document shares a vision for a 4-year curriculum for Heritage Speakers of Spanish (HSS)/Spanish for Native Speakers (SNS), describing a course developed for SNS students within Mercy High School in San Francisco, California. The vision foresees an ever-increasing number of HSS and SNS students completing college level degree programs then…

  2. Marital Quality as a Moderator of the Effects of Poor Vision on Quality of Life Among Older Adults

    PubMed Central

    2011-01-01

    Objectives. This study assessed the moderating role of marital quality in the effects of subjective and objective vision on functional limitations, social isolation, and depressive symptomatology. Method. Data from 738 married older adults drawn from a probability-based representative sample of elders residing in the United States were used. Assessments included subjective and objective vision, marital quality variables (relationship satisfaction, supportive spouse behaviors, and free time spent with one’s spouse), and three aspects of quality of life (functional limitations, social isolation, and depressive symptomatology). Results. Moderated regression analyses found that relationship satisfaction and supportive spouse behaviors moderated the effects of poor self-reported vision on functional limitations and depressive symptoms and the effects of poor visual acuity on functional limitations. As hypothesized, poorer vision was unrelated to functional limitations and depressive symptoms in more satisfying marriages but predicted higher levels of both outcomes in less satisfying marriages. Contrary to expectations, higher levels of supportive spouse behaviors were associated with more functional limitations in respondents who reported poorer subjective and objective vision. Discussion. A marriage that is highly satisfying can mitigate the adverse effects of poor vision on functional limitations and depressive symptomatology in late life. The moderating role of supportive spouse behaviors in the link between poor vision and quality of life is less intuitive, however. Whereas relationship satisfaction may operate as a traditional buffer in the context of poor vision, supportive spouse behaviors may increase in response to or be ineffective in this context. PMID:21840838

  3. Federal regulation of vision enhancement devices for normal and abnormal vision

    NASA Astrophysics Data System (ADS)

    Drum, Bruce

    2006-09-01

    The Food and Drug Administration (FDA) evaluates the safety and effectiveness of medical devices and biological products as well as food and drugs. The FDA defines a device as a product that is intended, by physical means, to diagnose, treat, or prevent disease, or to affect the structure or function of the body. All vision enhancement devices fulfill this definition because they are intended to affect a function (vision) of the body. In practice, however, FDA historically has drawn a distinction between devices that are intended to enhance low vision as opposed to normal vision. Most low vision aids are therapeutic devices intended to compensate for visual impairment, and are actively regulated according to their level of risk to the patient. The risk level is usually low (e.g. Class I, exempt from 510(k) submission requirements for magnifiers that do not touch the eye), but can be as high as Class III (requiring a clinical trial and Premarket Approval (PMA) application) for certain implanted and prosthetic devices (e.g. intraocular telescopes and prosthetic retinal implants). In contrast, the FDA usually does not actively enforce its regulations for devices that are intended to enhance normal vision, are low risk, and do not have a medical intended use. However, if an implanted or prosthetic device were developed for enhancing normal vision, the FDA would likely decide to regulate it actively, because its intended use would entail a substantial medical risk to the user. Companies developing such devices should contact the FDA at an early stage to clarify their regulatory status.

  4. Color Vision and the Railways: Part 2. Comparison of the CN Lantern Used on the Canadian Railways and Railway LED Lantern Tests.

    PubMed

    Dain, Stephen J; Casolin, Armand; Long, Jennifer

    2015-02-01

    There are two currently available lantern tests that have their design based solely on the practices of the rail industry. These are the CN Lantern (CNLAN) used on the Canadian Railways and the Railway LED Lantern Tests (RLLT). In the same way that the signaling practices differ in the two jurisdictions, the design of the lanterns also differ. The CIE (Commission Internationale de l'Éclairage)-recommended color vision standards for transport predate both lanterns. The study was undertaken to assess the appropriateness of these lanterns in CIE Color Vision Standard 1. CIE Standard 1 is called "Normal color vision" but some very mild anomalous trichromats may pass the specified "lantern test that presents a high level of difficulty." The lantern tests were undertaken by 46 color vision-normal and 37 color vision-deficient subjects. Subjects made more errors on the RLLT, and the pattern of errors is different, partly because there are blank presentations in the RLLT and "no light" is an acceptable response. The two lanterns showed agreement on the pass/fail categorization of 73 of the 83 subjects. The RLLT fails more color vision-normal subjects. Despite the different construction principles, the RLLT and CNLAN have pass/fail levels that are comparable with the Holmes-Wright Type B lantern, which is nominated in CIE Color Vision Standard 1 but is no longer commercially available. The higher failure rate of color vision-normal subjects on the RLLT has been addressed by changing the intensities of the two darkest red lights.

  5. Computer vision syndrome and ergonomic practices among undergraduate university students.

    PubMed

    Mowatt, Lizette; Gordon, Carron; Santosh, Arvind Babu Rajendra; Jones, Thaon

    2018-01-01

    To determine the prevalence of computer vision syndrome (CVS) and ergonomic practices among students in the Faculty of Medical Sciences at The University of the West Indies (UWI), Jamaica. A cross-sectional study was done with a self-administered questionnaire. Four hundred and nine students participated; 78% were females. The mean age was 21.6 years. Neck pain (75.1%), eye strain (67%), shoulder pain (65.5%) and eye burn (61.9%) were the most common CVS symptoms. Dry eyes (26.2%), double vision (28.9%) and blurred vision (51.6%) were the least commonly experienced symptoms. Eye burning (P = .001), eye strain (P = .041) and neck pain (P = .023) were significantly related to level of viewing. Moderate eye burning (55.1%) and double vision (56%) occurred in those who used handheld devices (P = .001 and .007, respectively). Moderate blurred vision was reported in 52% who looked down at the device compared with 14.8% who held it at an angle. Severe eye strain occurred in 63% of those who looked down at a device compared with 21% who kept the device at eye level. Shoulder pain was not related to pattern of use. Ocular symptoms and neck pain were less likely if the device was held just below eye level. There is a high prevalence of Symptoms of CVS amongst university students which could be reduced, in particular neck pain and eye strain and burning, with improved ergonomic practices. © 2017 John Wiley & Sons Ltd.

  6. A chronometric exploration of high-resolution 'sensitive TMS masking' effects on subjective and objective measures of vision.

    PubMed

    de Graaf, Tom A; Herring, Jim; Sack, Alexander T

    2011-03-01

    Transcranial magnetic stimulation (TMS) can induce masking by interfering with ongoing neural activity in early visual cortex. Previous work has explored the chronometry of occipital involvement in vision by using single pulses of TMS with high temporal resolution. However, conventionally TMS intensities have been high and the only measure used to evaluate masking was objective in nature. Recent studies have begun to incorporate subjective measures of vision, alongside objective ones. The current study goes beyond previous work in two regards. First, we explored both objective vision (an orientation discrimination task) and subjective vision (a stimulus visibility rating on a four-point scale), across a wide range of time windows with high temporal resolution. Second, we used a very sensitive TMS-masking paradigm: stimulation was at relatively low TMS intensities, with a figure-8 coil, and the small stimulus was difficult to discriminate already at baseline level. We hypothesized that this should increase the effective temporal resolution of our paradigm. Perhaps for this reason, we are able to report a rather interesting masking curve. Within the classical-masking time window, previously reported to encompass broad SOAs anywhere between 60 and 120 ms, we report not one, but at least two dips in objective performance, with no masking in-between. The subjective measure of vision did not mirror this pattern. These preliminary data from our exploratory design suggest that, with sensitive TMS masking, we might be able to reveal visual processes in early visual cortex previously unreported.

  7. Neuropsychological Components of Imagery Processing, Final Technical Report.

    ERIC Educational Resources Information Center

    Kosslyn, Stephen M.

    High-level visual processes make use of stored information, and are invoked during object identification, navigation, tracking, and visual mental imagery. The work presented in this document has resulted in a theory of the component "processing subsystems" used in high-level vision. This theory was developed by considering…

  8. Vision and Control for UAVs: A Survey of General Methods and of Inexpensive Platforms for Infrastructure Inspection

    PubMed Central

    Máthé, Koppány; Buşoniu, Lucian

    2015-01-01

    Unmanned aerial vehicles (UAVs) have gained significant attention in recent years. Low-cost platforms using inexpensive sensor payloads have been shown to provide satisfactory flight and navigation capabilities. In this report, we survey vision and control methods that can be applied to low-cost UAVs, and we list some popular inexpensive platforms and application fields where they are useful. We also highlight the sensor suites used where this information is available. We overview, among others, feature detection and tracking, optical flow and visual servoing, low-level stabilization and high-level planning methods. We then list popular low-cost UAVs, selecting mainly quadrotors. We discuss applications, restricting our focus to the field of infrastructure inspection. Finally, as an example, we formulate two use-cases for railway inspection, a less explored application field, and illustrate the usage of the vision and control techniques reviewed by selecting appropriate ones to tackle these use-cases. To select vision methods, we run a thorough set of experimental evaluations. PMID:26121608

  9. High-Level Vision and Planning Workshop Proceedings

    DTIC Science & Technology

    1989-08-01

    Correspondence in Line Drawings of Multiple View-. In Proc. of 8th Intern. Joint Conf. on Artificial intellignece . 1983. [63] Tomiyasu, K. Tutorial...joint U.S.-Israeli workshop on artificial intelligence are provided in this Institute for Defense Analyses document. This document is based on a broad...participants is provided along with applicable references for individual papers. 14. SUBJECT TERMS 15. NUMBER OF PAGES Artificial Intelligence; Machine Vision

  10. Composite Measures of Individual and Area-Level Socio-Economic Status Are Associated with Visual Impairment in Singapore

    PubMed Central

    Wah, Win; Earnest, Arul; Sabanayagam, Charumathi; Cheng, Ching-Yu; Ong, Marcus Eng Hock; Wong, Tien Y.; Lamoureux, Ecosse L.

    2015-01-01

    Purpose To investigate the independent relationship of individual- and area-level socio-economic status (SES) with the presence and severity of visual impairment (VI) in an Asian population. Methods Cross-sectional data from 9993 Chinese, Malay and Indian adults aged 40–80 years who participated in the Singapore Epidemiology of eye Diseases (2004–2011) in Singapore. Based on the presenting visual acuity (PVA) in the better-seeing eye, VI was categorized into normal vision (logMAR≤0.30), low vision (logMAR>0.30<1.00), and blindness (logMAR≥1.00). Any VI was defined as low vision/blindness in the PVA of better-seeing eye. Individual-level low-SES was defined as a composite of primary-level education, monthly income<2000 SGD and residing in 1 or 2-room public apartment. An area-level SES was assessed using a socio-economic disadvantage index (SEDI), created using 12 variables from the 2010 Singapore census. A high SEDI score indicates a relatively poor SES. Associations between SES measures and presence and severity of VI were examined using multi-level, mixed-effects logistic and multinomial regression models. Results The age-adjusted prevalence of any VI was 19.62% (low vision = 19%, blindness = 0.62%). Both individual- and area-level SES were positively associated with any VI and low vision after adjusting for confounders. The odds ratio (95% confidence interval) of any VI was 2.11(1.88–2.37) for low-SES and 1.07(1.02–1.13) per 1 standard deviation increase in SEDI. When stratified by unilateral/bilateral categories, while low SES showed significant associations with all categories, SEDI showed a significant association with bilateral low vision only. The association between low SES and any VI remained significant among all age, gender and ethnic sub-groups. Although a consistent positive association was observed between area-level SEDI and any VI, the associations were significant among participants aged 40–65 years and male. Conclusion In this community-based sample of Asian adults, both individual- and area-level SES were independently associated with the presence and severity of VI. PMID:26555141

  11. The role of personal purpose and personal goals in symbiotic visions.

    PubMed

    Berg, Jodi L

    2015-01-01

    It is believed that symbiotic visions can drive employees and organizations toward a common objective based on the premise that people have a high level of self-motivation and engagement when they are working toward something very personal. The field of organizational development has been aspiring to help organizations and people align their visions for decades without much, if any, empirical support for the role of personal purpose and goals in the symbiotic relationship with a company vision. This qualitative study examines the role personal purpose and goals play in how high performing leaders align to their company's vision. Whether and how senior managers articulate this alignment, and its correlation to their motivation and engagement, was examined. An observation was that most senior managers within organizations with a well-developed and widely known higher purpose vision are driven by something personal, identified as either personal goals or a personal purpose. One of the key findings is that personal purpose and goals, when aligned to a company vision, appear to impact motivation and engagement in different ways. When alignment is felt through the sense of the greater purpose, there is a deep, almost spiritual, commitment to making the world a better place and helping the organization contribute to that. This seems to motivate them to guide the organization toward its higher purpose vision. When alignment is felt through the organization's alignment to one's personal goals, there is a great sense of commitment to completing the steps or tasks necessary to move toward the vision, yet a clear delineation between work and life ambitions.

  12. The role of personal purpose and personal goals in symbiotic visions

    PubMed Central

    Berg, Jodi L.

    2015-01-01

    It is believed that symbiotic visions can drive employees and organizations toward a common objective based on the premise that people have a high level of self-motivation and engagement when they are working toward something very personal. The field of organizational development has been aspiring to help organizations and people align their visions for decades without much, if any, empirical support for the role of personal purpose and goals in the symbiotic relationship with a company vision. This qualitative study examines the role personal purpose and goals play in how high performing leaders align to their company's vision. Whether and how senior managers articulate this alignment, and its correlation to their motivation and engagement, was examined. An observation was that most senior managers within organizations with a well-developed and widely known higher purpose vision are driven by something personal, identified as either personal goals or a personal purpose. One of the key findings is that personal purpose and goals, when aligned to a company vision, appear to impact motivation and engagement in different ways. When alignment is felt through the sense of the greater purpose, there is a deep, almost spiritual, commitment to making the world a better place and helping the organization contribute to that. This seems to motivate them to guide the organization toward its higher purpose vision. When alignment is felt through the organization's alignment to one's personal goals, there is a great sense of commitment to completing the steps or tasks necessary to move toward the vision, yet a clear delineation between work and life ambitions. PMID:25926808

  13. Effects of vision on head-putter coordination in golf.

    PubMed

    Gonzalez, David Antonio; Kegel, Stefan; Ishikura, Tadao; Lee, Tim

    2012-07-01

    Low-skill golfers coordinate the movements of their head and putter with an allocentric, isodirectional coupling, which is opposite to the allocentric, antidirectional coordination pattern used by experts (Lee, Ishikura, Kegel, Gonzalez, & Passmore, 2008). The present study investigated the effects of four vision conditions (full vision, no vision, target focus, and ball focus) on head-putter coupling in low-skill golfers. Performance in the absence of vision resulted in a level of high isodirectional coupling that was similar to the full vision condition. However, when instructed to focus on the target during the putt, or focus on the ball through a restricted viewing angle, low-skill golfers significantly decoupled the head--putter coordination pattern. However, outcome measures demonstrated that target focus resulted in poorer performance compared with the other visual conditions, thereby providing overall support for use of a ball focus strategy to enhance coordination and outcome performance. Focus of attention and reduced visual tracking were hypothesized as potential reasons for the decoupling.

  14. Effects of contour enhancement on low-vision preference and visual search.

    PubMed

    Satgunam, Premnandhini; Woods, Russell L; Luo, Gang; Bronstad, P Matthew; Reynolds, Zachary; Ramachandra, Chaithanya; Mel, Bartlett W; Peli, Eli

    2012-09-01

    To determine whether image enhancement improves visual search performance and whether enhanced images were also preferred by subjects with vision impairment. Subjects (n = 24) with vision impairment (vision: 20/52 to 20/240) completed visual search and preference tasks for 150 static images that were enhanced to increase object contours' visual saliency. Subjects were divided into two groups and were shown three enhancement levels. Original and medium enhancements were shown to both groups. High enhancement was shown to group 1, and low enhancement was shown to group 2. For search, subjects pointed to an object that matched a search target displayed at the top left of the screen. An "integrated search performance" measure (area under the curve of cumulative correct response rate over search time) quantified performance. For preference, subjects indicated the preferred side when viewing the same image with different enhancement levels on side-by-side high-definition televisions. Contour enhancement did not improve performance in the visual search task. Group 1 subjects significantly (p < 0.001) rejected the High enhancement, and showed no preference for medium enhancement over the original images. Group 2 subjects significantly preferred (p < 0.001) both the medium and the low enhancement levels over original. Contrast sensitivity was correlated with both preference and performance; subjects with worse contrast sensitivity performed worse in the search task (ρ = 0.77, p < 0.001) and preferred more enhancement (ρ = -0.47, p = 0.02). No correlation between visual search performance and enhancement preference was found. However, a small group of subjects (n = 6) in a narrow range of mid-contrast sensitivity performed better with the enhancement, and most (n = 5) also preferred the enhancement. Preferences for image enhancement can be dissociated from search performance in people with vision impairment. Further investigations are needed to study the relationships between preference and performance for a narrow range of mid-contrast sensitivity where a beneficial effect of enhancement may exist.

  15. Compassion in practice-Evaluating the awareness, involvement and perceived impact of a national nursing and midwifery strategy amongst healthcare professionals in NHS Trusts in England.

    PubMed

    O'Driscoll, Mike; Allan, Helen; Liu, Liang; Corbett, Kevin; Serrant, Laura

    2018-03-01

    To report the findings from an evaluation of the impact of the Compassion in Practice Vision and Strategy (National Health Service England (NHSE), 2012) on nursing, midwifery and care staff. The Compassion in Practice Vision and Strategy was a programme of work to highlight the importance of compassionate care following the Francis Report in 2013 into the deficits in care in an NHS Hospital Trust. It was launched by NHS England in 2012 at a time when fiscal cuts were introduced by the Department of Health in England. Mixed methods. Inferential statistics were used to test whether there were significant differences between staff at different levels of seniority with regard to awareness and involvement in Compassion in Practice Vision and Strategy and their attitudes to it. Awareness and involvement of staff in Compassion in Practice Vision and Strategy were high amongst middle and senior management but limited at ward level. Staff involvement in Compassion in Practice Vision and Strategy was limited due to a lack of awareness. Ward level staff who were aware and involved, perceived a lack of support and communication from senior leadership to deliver the Compassion in Practice Vision and Strategy. Results reveal professional anger, distress and resistance to the Compassion in Practice Vision and Strategy and a view of the programme as a top-down initiative which did not sufficiently recognise structural constraints on nurses' ability to deliver compassionate care. We discuss the implications of our findings for global nursing. Participants emphasised that compassion for patients is only sustainable where there is compassion for staff and many participants felt that they were not being treated with compassion. National Health Service England should strongly affirm that nurses and midwives in general provide compassionate care. Trust leadership should provide support for ward level staff who deliver compassionate care in difficult circumstances. © 2017 John Wiley & Sons Ltd.

  16. Zif268 mRNA Expression Patterns Reveal a Distinct Impact of Early Pattern Vision Deprivation on the Development of Primary Visual Cortical Areas in the Cat.

    PubMed

    Laskowska-Macios, Karolina; Zapasnik, Monika; Hu, Tjing-Tjing; Kossut, Malgorzata; Arckens, Lutgarde; Burnat, Kalina

    2015-10-01

    Pattern vision deprivation (BD) can induce permanent deficits in global motion perception. The impact of timing and duration of BD on the maturation of the central and peripheral visual field representations in cat primary visual areas 17 and 18 remains unknown. We compared early BD, from eye opening for 2, 4, or 6 months, with late onset BD, after 2 months of normal vision, using the expression pattern of the visually driven activity reporter gene zif268 as readout. Decreasing zif268 mRNA levels between months 2 and 4 characterized the normal maturation of the (supra)granular layers of the central and peripheral visual field representations in areas 17 and 18. In general, all BD conditions had higher than normal zif268 levels. In area 17, early BD induced a delayed decrease, beginning later in peripheral than in central area 17. In contrast, the decrease occurred between months 2 and 4 throughout area 18. Lack of pattern vision stimulation during the first 4 months of life therefore has a different impact on the development of areas 17 and 18. A high zif268 expression level at a time when normal vision is restored seems to predict the capacity of a visual area to compensate for BD. © The Author 2014. Published by Oxford University Press.

  17. Computational approaches to vision

    NASA Technical Reports Server (NTRS)

    Barrow, H. G.; Tenenbaum, J. M.

    1986-01-01

    Vision is examined in terms of a computational process, and the competence, structure, and control of computer vision systems are analyzed. Theoretical and experimental data on the formation of a computer vision system are discussed. Consideration is given to early vision, the recovery of intrinsic surface characteristics, higher levels of interpretation, and system integration and control. A computational visual processing model is proposed and its architecture and operation are described. Examples of state-of-the-art vision systems, which include some of the levels of representation and processing mechanisms, are presented.

  18. High-Level Vision: Top-Down Processing in Neurally Inspired Architectures

    DTIC Science & Technology

    2008-02-01

    shunting subsystem). Visual input from the lateral geniculate enters the visual buffer via the black arrow at the bottom. Processing subsystems used... lateral geniculate nucleus of the thalamus (LGNd), the superior colliculus of the midbrain, and cortical regions V1 through V4. Beyond early vision...resonance imaging FOA: focus of attention IMPER: IMagery and PERception model IS: information shunting system LGNd: dorsal lateral geniculate nucleus

  19. High accuracy position method based on computer vision and error analysis

    NASA Astrophysics Data System (ADS)

    Chen, Shihao; Shi, Zhongke

    2003-09-01

    The study of high accuracy position system is becoming the hotspot in the field of autocontrol. And positioning is one of the most researched tasks in vision system. So we decide to solve the object locating by using the image processing method. This paper describes a new method of high accuracy positioning method through vision system. In the proposed method, an edge-detection filter is designed for a certain running condition. Here, the filter contains two mainly parts: one is image-processing module, this module is to implement edge detection, it contains of multi-level threshold self-adapting segmentation, edge-detection and edge filter; the other one is object-locating module, it is to point out the location of each object in high accurate, and it is made up of medium-filtering and curve-fitting. This paper gives some analysis error for the method to prove the feasibility of vision in position detecting. Finally, to verify the availability of the method, an example of positioning worktable, which is using the proposed method, is given at the end of the paper. Results show that the method can accurately detect the position of measured object and identify object attitude.

  20. Scene and human face recognition in the central vision of patients with glaucoma

    PubMed Central

    Aptel, Florent; Attye, Arnaud; Guyader, Nathalie; Boucart, Muriel; Chiquet, Christophe; Peyrin, Carole

    2018-01-01

    Primary open-angle glaucoma (POAG) firstly mainly affects peripheral vision. Current behavioral studies support the idea that visual defects of patients with POAG extend into parts of the central visual field classified as normal by static automated perimetry analysis. This is particularly true for visual tasks involving processes of a higher level than mere detection. The purpose of this study was to assess visual abilities of POAG patients in central vision. Patients were assigned to two groups following a visual field examination (Humphrey 24–2 SITA-Standard test). Patients with both peripheral and central defects and patients with peripheral but no central defect, as well as age-matched controls, participated in the experiment. All participants had to perform two visual tasks where low-contrast stimuli were presented in the central 6° of the visual field. A categorization task of scene images and human face images assessed high-level visual recognition abilities. In contrast, a detection task using the same stimuli assessed low-level visual function. The difference in performance between detection and categorization revealed the cost of high-level visual processing. Compared to controls, patients with a central visual defect showed a deficit in both detection and categorization of all low-contrast images. This is consistent with the abnormal retinal sensitivity as assessed by perimetry. However, the deficit was greater for categorization than detection. Patients without a central defect showed similar performances to the controls concerning the detection and categorization of faces. However, while the detection of scene images was well-maintained, these patients showed a deficit in their categorization. This suggests that the simple loss of peripheral vision could be detrimental to scene recognition, even when the information is displayed in central vision. This study revealed subtle defects in the central visual field of POAG patients that cannot be predicted by static automated perimetry assessment using Humphrey 24–2 SITA-Standard test. PMID:29481572

  1. Robust object tracking techniques for vision-based 3D motion analysis applications

    NASA Astrophysics Data System (ADS)

    Knyaz, Vladimir A.; Zheltov, Sergey Y.; Vishnyakov, Boris V.

    2016-04-01

    Automated and accurate spatial motion capturing of an object is necessary for a wide variety of applications including industry and science, virtual reality and movie, medicine and sports. For the most part of applications a reliability and an accuracy of the data obtained as well as convenience for a user are the main characteristics defining the quality of the motion capture system. Among the existing systems for 3D data acquisition, based on different physical principles (accelerometry, magnetometry, time-of-flight, vision-based), optical motion capture systems have a set of advantages such as high speed of acquisition, potential for high accuracy and automation based on advanced image processing algorithms. For vision-based motion capture accurate and robust object features detecting and tracking through the video sequence are the key elements along with a level of automation of capturing process. So for providing high accuracy of obtained spatial data the developed vision-based motion capture system "Mosca" is based on photogrammetric principles of 3D measurements and supports high speed image acquisition in synchronized mode. It includes from 2 to 4 technical vision cameras for capturing video sequences of object motion. The original camera calibration and external orientation procedures provide the basis for high accuracy of 3D measurements. A set of algorithms as for detecting, identifying and tracking of similar targets, so for marker-less object motion capture is developed and tested. The results of algorithms' evaluation show high robustness and high reliability for various motion analysis tasks in technical and biomechanics applications.

  2. A programmable computational image sensor for high-speed vision

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Shi, Cong; Long, Xitian; Wu, Nanjian

    2013-08-01

    In this paper we present a programmable computational image sensor for high-speed vision. This computational image sensor contains four main blocks: an image pixel array, a massively parallel processing element (PE) array, a row processor (RP) array and a RISC core. The pixel-parallel PE is responsible for transferring, storing and processing image raw data in a SIMD fashion with its own programming language. The RPs are one dimensional array of simplified RISC cores, it can carry out complex arithmetic and logic operations. The PE array and RP array can finish great amount of computation with few instruction cycles and therefore satisfy the low- and middle-level high-speed image processing requirement. The RISC core controls the whole system operation and finishes some high-level image processing algorithms. We utilize a simplified AHB bus as the system bus to connect our major components. Programming language and corresponding tool chain for this computational image sensor are also developed.

  3. Landing performance by low-time private pilots after the sudden loss of binocular vision - Cyclops II

    NASA Technical Reports Server (NTRS)

    Lewis, C. E., Jr.; Swaroop, R.; Mcmurty, T. C.; Blakeley, W. R.; Masters, R. L.

    1973-01-01

    Study of low-time general aviation pilots, who, in a series of spot landings, were suddenly deprived of binocular vision by patching either eye on the downwind leg of a standard, closed traffic pattern. Data collected during these landings were compared with control data from landings flown with normal vision during the same flight. The sequence of patching and the mix of control and monocular landings were randomized to minimize the effect of learning. No decrease in performance was observed during landings with vision restricted to one eye, in fact, performance improved. This observation is reported at a high level of confidence (p less than 0.001). These findings confirm the previous work of Lewis and Krier and have important implications with regard to aeromedical certification standards.

  4. The Effect of Gender and Level of Vision on the Physical Activity Level of Children and Adolescents with Visual Impairment

    ERIC Educational Resources Information Center

    Aslan, Ummuhan Bas; Calik, Bilge Basakci; Kitis, Ali

    2012-01-01

    This study was planned in order to determine physical activity levels of visually impaired children and adolescents and to investigate the effect of gender and level of vision on physical activity level in visually impaired children and adolescents. A total of 30 visually impaired children and adolescents (16 low vision and 14 blind) aged between…

  5. Influence of restricted vision and knee joint range of motion on gait properties during level walking and stair ascent and descent.

    PubMed

    Demura, Tomohiro; Demura, Shin-ich

    2011-01-01

    Because elderly individuals experience marked declines in various physical functions (e.g., vision, joint function) simultaneously, it is difficult to clarify the individual effects of these functional declines on walking. However, by imposing vision and joint function restrictions on young men, the effects of these functional declines on walking can be clarified. The authors aimed to determine the effect of restricted vision and range of motion (ROM) of the knee joint on gait properties while walking and ascending or descending stairs. Fifteen healthy young adults performed level walking and stair ascent and descent during control, vision restriction, and knee joint ROM restriction conditions. During level walking, walking speed and step width decreased, and double support time increased significantly with vision and knee joint ROM restrictions. Stance time, step width, and walking angle increased only with knee joint ROM restriction. Stance time, swing time, and double support time were significantly longer in level walking, stair descent, and stair ascent, in that order. The effects of vision and knee joint ROM restrictions were significantly larger than the control conditions. In conclusion, vision and knee joint ROM restrictions affect gait during level walking and stair ascent and descent. This effect is marked in stair ascent with knee joint ROM restriction.

  6. The effect of gender and level of vision on the physical activity level of children and adolescents with visual impairment.

    PubMed

    Aslan, Ummuhan Bas; Calik, Bilge Basakcı; Kitiş, Ali

    2012-01-01

    This study was planned in order to determine physical activity levels of visually impaired children and adolescents and to investigate the effect of gender and level of vision on physical activity level in visually impaired children and adolescents. A total of 30 visually impaired children and adolescents (16 low vision and 14 blind) aged between 8 and 16 years participated in the study. The physical activity level of cases was evaluated with a physical activity diary (PAD) and one-mile run/walk test (OMR-WT). No difference was found between the PAD and the OMR-WT results of low vision and blind children and adolescents. The visually impaired children and adolescents were detected not to participate in vigorous physical activity. A difference was found in favor of low vision boys in terms of mild, moderate activities and OMR-WT durations. However, no difference was found between physical activity levels of blind girls and boys. The results of our study suggested that the physical activity level of visually impaired children and adolescents was low, and gender affected physical activity in low vision children and adolescents. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Visual Impairment Screening at the Geriatric Frailty Clinic for Assessment of Frailty and Prevention of Disability at the Gérontopôle.

    PubMed

    Soler, V; Sourdet, S; Balardy, L; Abellan van Kan, G; Brechemier, D; Rougé-Bugat, M E; Tavassoli, N; Cassagne, M; Malecaze, F; Nourhashémi, F; Vellas, B

    2016-01-01

    To evaluate visual performance and factors associated with abnormal vision in patients screened for frailty at the Geriatric Frailty Clinic (GFC) for Assessment of Frailty and Prevention of Disability at Toulouse University Hospital. Retrospective, observational cross-sectional, single-centre study. Institutional practice. Patients were screened for frailty during a single-day hospital stay between October 2011 and October 2014 (n = 1648). Collected medical records included sociodemographic data (including living environment and educational level), anthropometric data, and clinical data. The general evaluation included the patient's functional status using the Activities of Daily Living (ADL) scale and the Instrumental Activity of Daily Living (IADL) scale, the Mini-Mental State Examination (MMSE) for cognition testing, and the Short Physical Performance Battery (SPPB) for physical performance. We also examined Body Mass Index (BMI), the Mini-Nutritional Assessment (MNA), and the Hearing Handicap Inventory for the Elderly Screening (HHIE-S) tool. The ophthalmologic evaluation included assessing visual acuity using the Snellen decimal chart for distant vision, and the Parinaud chart for near vision. Patients were divided into groups based on normal distant/near vision (NDV and NNV groups) and abnormal distant/near vision (ADV and ANV groups). Abnormal distant or near vision was defined as visual acuity inferior to 20/40 or superior to a Parinaud score of 2, in at least one eye. Associations with frailty-associated factors were evaluated in both groups. The mean age of the population was 82.6 ± 6.2 years. The gender distribution was 1,061 females (64.4%) and 587 males (35.6%). According to the Fried criteria, 619 patients (41.1%) were pre-frail and 771 (51.1%) were frail. Distant and near vision data were available for 1425 and 1426 patients, respectively. Distant vision was abnormal for 437 patients (30.7%). Near vision was abnormal for 199 patients (14%). Multiple regression analysis showed that abnormal distant vision as well as abnormal near vision were independently associated with greater age (P < 0.01), lower educational level (P < 0.05), lower performance on the MMSE (P < 0.001), and lower autonomy (P < 0.02), after controlling for age, gender, educational level, Fried criteria, and MMSE score. The high prevalence of visual disorders observed in the study population and their association with lower autonomy and cognitive impairment emphasises the need for systematic screening of visual impairments in the elderly. Frailty was not found to be independently associated with abnormal vision.

  8. Stereoacuity of preschool children with and without vision disorders.

    PubMed

    Ciner, Elise B; Ying, Gui-Shuang; Kulp, Marjean Taylor; Maguire, Maureen G; Quinn, Graham E; Orel-Bixler, Deborah; Cyert, Lynn A; Moore, Bruce; Huang, Jiayan

    2014-03-01

    To evaluate associations between stereoacuity and presence, type, and severity of vision disorders in Head Start preschool children and determine testability and levels of stereoacuity by age in children without vision disorders. Stereoacuity of children aged 3 to 5 years (n = 2898) participating in the Vision in Preschoolers (VIP) Study was evaluated using the Stereo Smile II test during a comprehensive vision examination. This test uses a two-alternative forced-choice paradigm with four stereoacuity levels (480 to 60 seconds of arc). Children were classified by the presence (n = 871) or absence (n = 2027) of VIP Study-targeted vision disorders (amblyopia, strabismus, significant refractive error, or unexplained reduced visual acuity), including type and severity. Median stereoacuity between groups and among severity levels of vision disorders was compared using Wilcoxon rank sum and Kruskal-Wallis tests. Testability and stereoacuity levels were determined for children without VIP Study-targeted disorders overall and by age. Children with VIP Study-targeted vision disorders had significantly worse median stereoacuity than that of children without vision disorders (120 vs. 60 seconds of arc, p < 0.001). Children with the most severe vision disorders had worse stereoacuity than that of children with milder disorders (median 480 vs. 120 seconds of arc, p < 0.001). Among children without vision disorders, testability was 99.6% overall, increasing with age to 100% for 5-year-olds (p = 0.002). Most of the children without vision disorders (88%) had stereoacuity at the two best disparities (60 or 120 seconds of arc); the percentage increasing with age (82% for 3-, 89% for 4-, and 92% for 5-year-olds; p < 0.001). The presence of any VIP Study-targeted vision disorder was associated with significantly worse stereoacuity in preschool children. Severe vision disorders were more likely associated with poorer stereopsis than milder or no vision disorders. Testability was excellent at all ages. These results support the validity of the Stereo Smile II for assessing random-dot stereoacuity in preschool children.

  9. Is vision function related to physical functional ability in older adults?

    PubMed

    West, Catherine G; Gildengorin, Ginny; Haegerstrom-Portnoy, Gunilla; Schneck, Marilyn E; Lott, Lori; Brabyn, John A

    2002-01-01

    To assess the relationship between a broad range of vision functions and measures of physical performance in older adults. Cross-sectional study. Population-based cohort of community-dwelling older adults, subset of an on-going longitudinal study. Seven hundred eighty-two adults aged 55 and older (65% of living eligible subjects) had subjective health measures and objective physical performance evaluated in 1989/91 and again in 1993/95 and a battery of vision functions tested in 1993/95. Comprehensive battery of vision tests (visual acuity, contrast sensitivity, effects of illumination level, contrast and glare on acuity, visual fields with and without attentional load, color vision, temporal sensitivity, and the impact of dimming light on walking ability) and physical function measures (self-reported mobility limitations and observed measures of walking, rising from a chair and tandem balance). The failure rate for all vision functions and physical performance measures increased exponentially with age. Standard high-contrast visual acuity and standard visual fields showed the lowest failure rates. Nonstandard vision tests showed much higher failure rates. Poor performance on many individual vision functions was significantly associated with particular individual measures of physical performance. Using constructed combination vision variables, significant associations were found between spatial vision, field integrity, binocularity and/or adaptation, and each of the functional outcomes. Vision functions other than standard visual acuity may affect day-to-day functioning of older adults. Additional studies of these other aspects of vision and how they can be treated or rehabilitated are needed to determine whether these aspects play a role in strategies for reducing disability in older adults.

  10. Computer vision camera with embedded FPGA processing

    NASA Astrophysics Data System (ADS)

    Lecerf, Antoine; Ouellet, Denis; Arias-Estrada, Miguel

    2000-03-01

    Traditional computer vision is based on a camera-computer system in which the image understanding algorithms are embedded in the computer. To circumvent the computational load of vision algorithms, low-level processing and imaging hardware can be integrated in a single compact module where a dedicated architecture is implemented. This paper presents a Computer Vision Camera based on an open architecture implemented in an FPGA. The system is targeted to real-time computer vision tasks where low level processing and feature extraction tasks can be implemented in the FPGA device. The camera integrates a CMOS image sensor, an FPGA device, two memory banks, and an embedded PC for communication and control tasks. The FPGA device is a medium size one equivalent to 25,000 logic gates. The device is connected to two high speed memory banks, an IS interface, and an imager interface. The camera can be accessed for architecture programming, data transfer, and control through an Ethernet link from a remote computer. A hardware architecture can be defined in a Hardware Description Language (like VHDL), simulated and synthesized into digital structures that can be programmed into the FPGA and tested on the camera. The architecture of a classical multi-scale edge detection algorithm based on a Laplacian of Gaussian convolution has been developed to show the capabilities of the system.

  11. Computer vision-based sorting of Atlantic salmon (Salmo salar) fillets according to their color level.

    PubMed

    Misimi, E; Mathiassen, J R; Erikson, U

    2007-01-01

    Computer vision method was used to evaluate the color of Atlantic salmon (Salmo salar) fillets. Computer vision-based sorting of fillets according to their color was studied on 2 separate groups of salmon fillets. The images of fillets were captured using a digital camera of high resolution. Images of salmon fillets were then segmented in the regions of interest and analyzed in red, green, and blue (RGB) and CIE Lightness, redness, and yellowness (Lab) color spaces, and classified according to the Roche color card industrial standard. Comparisons of fillet color between visual evaluations were made by a panel of human inspectors, according to the Roche SalmoFan lineal standard, and the color scores generated from computer vision algorithm showed that there were no significant differences between the methods. Overall, computer vision can be used as a powerful tool to sort fillets by color in a fast and nondestructive manner. The low cost of implementing computer vision solutions creates the potential to replace manual labor in fish processing plants with automation.

  12. Visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens: A prospective study

    PubMed Central

    Sachdev, Gitansha Shreyas; Ramamurthy, Shreyas; Sharma, Umesh; Dandapani, Ramamurthy

    2018-01-01

    Purpose: The aim of this study was to analyze the objective and subjective visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens (EROV IOL), the Tecnis Symfony. Methods: This was a prospective interventional case series conducted at a tertiary eye care hospital in South India. The study included patients with bilateral implantation of EROV IOLs. The uncorrected and corrected visual acuity for distance, intermediate, and near vision was recorded at 6 weeks and 6 months’ postoperative visit. A subjective questionnaire was administered to assess spectacle independence, photic phenomenon, and overall satisfaction. All data were recorded using Microsoft Excel worksheet. The analyses were performed using SPSS for windows software. Results: Our study included fifty patients with bilateral implantation of EROV IOLs. The mean age was 59.84 ± 11.68 years. The mean uncorrected binocular distance, intermediate, and near visual acuity (in standard decimal equivalent) was 0.89,0.99 and 0.99 respectively, at 6 months’ postoperative visit. Ninety-six percent of the patients did not require spectacles for distance and 98% of the patients were free from spectacles for intermediate and near vision. 94% of our patients perceived no or minimal photic phenomena such as glare and halos. The mean subjective patient satisfaction score (out of 10) for distance, intermediate, and near was 9, 10, and 9, respectively. Conclusion: The EROV IOLs demonstrated high levels of spectacle independence for distance, intermediate, and near vision. The incidence of photic phenomena observed was minimal with a high level of patient satisfaction. PMID:29480252

  13. Generic decoding of seen and imagined objects using hierarchical visual features.

    PubMed

    Horikawa, Tomoyasu; Kamitani, Yukiyasu

    2017-05-22

    Object recognition is a key function in both human and machine vision. While brain decoding of seen and imagined objects has been achieved, the prediction is limited to training examples. We present a decoding approach for arbitrary objects using the machine vision principle that an object category is represented by a set of features rendered invariant through hierarchical processing. We show that visual features, including those derived from a deep convolutional neural network, can be predicted from fMRI patterns, and that greater accuracy is achieved for low-/high-level features with lower-/higher-level visual areas, respectively. Predicted features are used to identify seen/imagined object categories (extending beyond decoder training) from a set of computed features for numerous object images. Furthermore, decoding of imagined objects reveals progressive recruitment of higher-to-lower visual representations. Our results demonstrate a homology between human and machine vision and its utility for brain-based information retrieval.

  14. Manifold learning in machine vision and robotics

    NASA Astrophysics Data System (ADS)

    Bernstein, Alexander

    2017-02-01

    Smart algorithms are used in Machine vision and Robotics to organize or extract high-level information from the available data. Nowadays, Machine learning is an essential and ubiquitous tool to automate extraction patterns or regularities from data (images in Machine vision; camera, laser, and sonar sensors data in Robotics) in order to solve various subject-oriented tasks such as understanding and classification of images content, navigation of mobile autonomous robot in uncertain environments, robot manipulation in medical robotics and computer-assisted surgery, and other. Usually such data have high dimensionality, however, due to various dependencies between their components and constraints caused by physical reasons, all "feasible and usable data" occupy only a very small part in high dimensional "observation space" with smaller intrinsic dimensionality. Generally accepted model of such data is manifold model in accordance with which the data lie on or near an unknown manifold (surface) of lower dimensionality embedded in an ambient high dimensional observation space; real-world high-dimensional data obtained from "natural" sources meet, as a rule, this model. The use of Manifold learning technique in Machine vision and Robotics, which discovers a low-dimensional structure of high dimensional data and results in effective algorithms for solving of a large number of various subject-oriented tasks, is the content of the conference plenary speech some topics of which are in the paper.

  15. Training-Induced Recovery of Low-Level Vision Followed by Mid-Level Perceptual Improvements in Developmental Object and Face Agnosia

    ERIC Educational Resources Information Center

    Lev, Maria; Gilaie-Dotan, Sharon; Gotthilf-Nezri, Dana; Yehezkel, Oren; Brooks, Joseph L.; Perry, Anat; Bentin, Shlomo; Bonneh, Yoram; Polat, Uri

    2015-01-01

    Long-term deprivation of normal visual inputs can cause perceptual impairments at various levels of visual function, from basic visual acuity deficits, through mid-level deficits such as contour integration and motion coherence, to high-level face and object agnosia. Yet it is unclear whether training during adulthood, at a post-developmental…

  16. Optical needs of students with low vision in integrated schools of Nepal.

    PubMed

    Gnyawali, Subodh; Shrestha, Jyoti Baba; Bhattarai, Dipesh; Upadhyay, Madan

    2012-12-01

    To identify the optical needs of students with low vision studying in the integrated schools for the blind in Nepal. A total of 779 blind and vision-impaired students studying in 67 integrated schools for the blind across Nepal were examined using the World Health Organization/Prevention of Blindness Eye Examination Record for Children with Blindness and Low Vision. Glasses and low-vision devices were provided to the students with low vision who showed improvement in visual acuity up to a level that was considered sufficient for classroom learning. Follow-up on the use and maintenance of device provided was done after a year. Almost 78% of students studying in the integrated schools for the blind were not actually blind; they had low vision. Five students were found to be wrongly enrolled. Avoidable causes of blindness were responsible for 41% of all blindness. Among 224 students who had visual acuity 1/60 or better, distance vision could be improved in 18.7% whereas near vision could be improved in 41.1% students. Optical intervention provided improved vision in 48.2% of students who were learning braille. Only 34.8% students were found to be using the devices regularly after assessment 1 year later; the most common causes for nonuse were damage or misplacement of the device. A high proportion of students with low vision in integrated schools could benefit from optical intervention. A system of comprehensive eye examination at the time of school enrollment would allow students with low vision to use their available vision to the fullest, encourage print reading over braille, ensure appropriate placement, and promote timely adoption and proper usage of optical device.

  17. 2016-2017 Status Assessment and Update on the Wind Vision Roadmap: Findings from Topical Working Sessions, April 2016 - March 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lantz, Eric J.; Mone, Christopher D.; DeMeo, Edgar

    IIn March 2015, the U.S. Department of Energy (DOE) released Wind Vision: A New Era for Wind Power in the United States (DOE 2015), which explores a scenario in which wind provides 10 percent of U.S. electricity in 2020, 20 percent in 2030, and 35 percent in 2050. The Wind Vision report also includes a roadmap of recommended actions aimed at pursuit of the vision and its underlying wind-deployment scenario. The roadmap was compiled by the Wind Vision project team, which included representatives from the industrial, electric-power, government-laboratory, academic, environmental-stewardship, regulatory, and permitting stakeholder groups. The roadmap describes high-level activitiesmore » suitable for all sectors with a stake in wind power and energy development. It is intended to be a 'living document,' and DOE expects to engage the wind community from time to time to track progress.« less

  18. NETRA: A parallel architecture for integrated vision systems. 1: Architecture and organization

    NASA Technical Reports Server (NTRS)

    Choudhary, Alok N.; Patel, Janak H.; Ahuja, Narendra

    1989-01-01

    Computer vision is regarded as one of the most complex and computationally intensive problems. An integrated vision system (IVS) is considered to be a system that uses vision algorithms from all levels of processing for a high level application (such as object recognition). A model of computation is presented for parallel processing for an IVS. Using the model, desired features and capabilities of a parallel architecture suitable for IVSs are derived. Then a multiprocessor architecture (called NETRA) is presented. This architecture is highly flexible without the use of complex interconnection schemes. The topology of NETRA is recursively defined and hence is easily scalable from small to large systems. Homogeneity of NETRA permits fault tolerance and graceful degradation under faults. It is a recursively defined tree-type hierarchical architecture where each of the leaf nodes consists of a cluster of processors connected with a programmable crossbar with selective broadcast capability to provide for desired flexibility. A qualitative evaluation of NETRA is presented. Then general schemes are described to map parallel algorithms onto NETRA. Algorithms are classified according to their communication requirements for parallel processing. An extensive analysis of inter-cluster communication strategies in NETRA is presented, and parameters affecting performance of parallel algorithms when mapped on NETRA are discussed. Finally, a methodology to evaluate performance of algorithms on NETRA is described.

  19. Robust algebraic image enhancement for intelligent control systems

    NASA Technical Reports Server (NTRS)

    Lerner, Bao-Ting; Morrelli, Michael

    1993-01-01

    Robust vision capability for intelligent control systems has been an elusive goal in image processing. The computationally intensive techniques a necessary for conventional image processing make real-time applications, such as object tracking and collision avoidance difficult. In order to endow an intelligent control system with the needed vision robustness, an adequate image enhancement subsystem capable of compensating for the wide variety of real-world degradations, must exist between the image capturing and the object recognition subsystems. This enhancement stage must be adaptive and must operate with consistency in the presence of both statistical and shape-based noise. To deal with this problem, we have developed an innovative algebraic approach which provides a sound mathematical framework for image representation and manipulation. Our image model provides a natural platform from which to pursue dynamic scene analysis, and its incorporation into a vision system would serve as the front-end to an intelligent control system. We have developed a unique polynomial representation of gray level imagery and applied this representation to develop polynomial operators on complex gray level scenes. This approach is highly advantageous since polynomials can be manipulated very easily, and are readily understood, thus providing a very convenient environment for image processing. Our model presents a highly structured and compact algebraic representation of grey-level images which can be viewed as fuzzy sets.

  20. High definition spectral domain optical coherence tomography findings in three patients with solar retinopathy and review of the literature.

    PubMed

    Chen, Kevin C; Jung, Jesse J; Aizman, Alexander

    2012-01-01

    To describe ocular findings in 3 cases of solar retinopathy using high definition, spectral domain optical coherence tomography (SD-OCT) and review the literature for optical coherence tomography (OCT) characteristics associated with worse vision. Case series and retrospective review of clinical features and Spectralis SD-OCT (Heidelberg Engineering, Vista, California, United States of America). A literature review of OCT findings in cases of solar retinopathy reported on MEDLINE was also performed and analyzed. Six eyes of 3 patients with solar retinopathy revealed significant foveal pathology. Visual acuity ranged from Snellen 20/30 to 20/50. High definition SD-OCT demonstrated defects at the level of the inner and outer segment junction of the photoreceptors as well as in the inner high reflective layer. There was a significant correlation between chronic disruption of the inner photoreceptor junction with worse vision based on the current case series and literature review. Screening patients with exposure to central foveal damage from solar retinopathy with high definition SD-OCT improves diagnosis and assessment of photoreceptor damage and vision loss.

  1. The impact of individual characteristics in self-esteem and locus of control of young adults with visual impairments.

    PubMed

    Papadopoulos, Konstantinos

    2014-03-01

    In this study the impact of personal/individual characteristics (gender, vision status, age, age at loss of sight, recency of vision loss, education level, employment status, and ability of independent movement) in locus of control (LOC) and self-esteem were examined. Eighty-four young adults with visual impairments (42 with blindness and 42 with low vision) took part in this study. The significant predictors of self-esteem were vision status, age at loss of sight, recency of vision loss and educational level. Moreover, significant predictors of LOC were vision status and independent movement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. A digital retina-like low-level vision processor.

    PubMed

    Mertoguno, S; Bourbakis, N G

    2003-01-01

    This correspondence presents the basic design and the simulation of a low level multilayer vision processor that emulates to some degree the functional behavior of a human retina. This retina-like multilayer processor is the lower part of an autonomous self-organized vision system, called Kydon, that could be used on visually impaired people with a damaged visual cerebral cortex. The Kydon vision system, however, is not presented in this paper. The retina-like processor consists of four major layers, where each of them is an array processor based on hexagonal, autonomous processing elements that perform a certain set of low level vision tasks, such as smoothing and light adaptation, edge detection, segmentation, line recognition and region-graph generation. At each layer, the array processor is a 2D array of k/spl times/m hexagonal identical autonomous cells that simultaneously execute certain low level vision tasks. Thus, the hardware design and the simulation at the transistor level of the processing elements (PEs) of the retina-like processor and its simulated functionality with illustrative examples are provided in this paper.

  3. The research of edge extraction and target recognition based on inherent feature of objects

    NASA Astrophysics Data System (ADS)

    Xie, Yu-chan; Lin, Yu-chi; Huang, Yin-guo

    2008-03-01

    Current research on computer vision often needs specific techniques for particular problems. Little use has been made of high-level aspects of computer vision, such as three-dimensional (3D) object recognition, that are appropriate for large classes of problems and situations. In particular, high-level vision often focuses mainly on the extraction of symbolic descriptions, and pays little attention to the speed of processing. In order to extract and recognize target intelligently and rapidly, in this paper we developed a new 3D target recognition method based on inherent feature of objects in which cuboid was taken as model. On the basis of analysis cuboid nature contour and greyhound distributing characteristics, overall fuzzy evaluating technique was utilized to recognize and segment the target. Then Hough transform was used to extract and match model's main edges, we reconstruct aim edges by stereo technology in the end. There are three major contributions in this paper. Firstly, the corresponding relations between the parameters of cuboid model's straight edges lines in an image field and in the transform field were summed up. By those, the aimless computations and searches in Hough transform processing can be reduced greatly and the efficiency is improved. Secondly, as the priori knowledge about cuboids contour's geometry character known already, the intersections of the component extracted edges are taken, and assess the geometry of candidate edges matches based on the intersections, rather than the extracted edges. Therefore the outlines are enhanced and the noise is depressed. Finally, a 3-D target recognition method is proposed. Compared with other recognition methods, this new method has a quick response time and can be achieved with high-level computer vision. The method present here can be used widely in vision-guide techniques to strengthen its intelligence and generalization, which can also play an important role in object tracking, port AGV, robots fields. The results of simulation experiments and theory analyzing demonstrate that the proposed method could suppress noise effectively, extracted target edges robustly, and achieve the real time need. Theory analysis and experiment shows the method is reasonable and efficient.

  4. National Science Education Standards.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC.

    The National Science Education Standards present a vision of a scientifically literate populace. The standards outline what students need to know, understand, and be able to do to be scientifically literate at different grade levels. They describe an educational system in which all students demonstrate high levels of performance, teachers are…

  5. Treating presbyopia without spectacles

    NASA Astrophysics Data System (ADS)

    Xu, Renfeng

    Both multifocal optics and small pupils can increase the depth of focus (DoF) of presbyopes. This thesis will evaluate some of the unique challenges faced by each of these two strategies. First, there is no single spherical refracting lens that can focus all parts of the pupil of an aberrated eye. What is the objective and subjective spherical refractive error (Rx) for such an eye, and does it vary with the amount of primary SA? Using both computational modeling and psychophysical methods, we found that high levels of positive Seidel SA caused both objective and subjective refractions to become myopic. Significantly, this refractive shift varied with stimulus spatial frequency and subjective criterion. Second, although secondary SA can dramatically expand DoF, we show that this is mostly due to the lower order components within this polynomial, which can also change spherical Rx. Also, the r6 term that defines secondary SA actually narrows rather than expands DoF, when in the presence of the r4 term within Z60. Finally, as retinal illuminance drops, neural thresholds are elevated due to increased problems of photon noise. We asked if the gains in near and distant vision of presbyopes anticipated at high light levels would be cancelled or even reversed at low light levels because of the additional reduction in retinal illuminance contributed by small pupils. We found that when light levels are > 2 cd/m2, a small pupil with a diameter of 2--3mm improves near image quality, near visual acuity, and near reading speed without significant loss of distance image quality and distance vision. This result gains added significance because we also showed that low light level text in the urban environment always has luminance levels > 2 cd/m2. In conclusion, both small pupils and multifocal optics face significant challenges as near vision aids for presbyopes. However, some of the confounding effects of elevated SA levels are avoided by using small pupils to expand DoF, which can provide improved near and distance vision at most light levels encountered while reading.

  6. Using Multiple FPGA Architectures for Real-time Processing of Low-level Machine Vision Functions

    Treesearch

    Thomas H. Drayer; William E. King; Philip A. Araman; Joseph G. Tront; Richard W. Conners

    1995-01-01

    In this paper, we investigate the use of multiple Field Programmable Gate Array (FPGA) architectures for real-time machine vision processing. The use of FPGAs for low-level processing represents an excellent tradeoff between software and special purpose hardware implementations. A library of modules that implement common low-level machine vision operations is presented...

  7. A coalition partnership of vision health through a health-promoting school program for primary school students in Taiwan.

    PubMed

    Chang, Li-Chun; Guo, Jong-Long; Liao, Li-Ling; Peng, Hsiu-Ying; Hsieh, Pei-Lin

    2017-09-01

    Myopia, the most common refractive error, is the most common cause of avoidable visual impairment among children and has reached epidemic proportions among children and young adults in urban areas of East and Southeast Asia that contain populations of Chinese ancestry. Moreover, vision health is an important theme of the health-promoting school program issued by the Ministry of Education in Taiwan. The aim of this study is to assess the impact of pre- and post-intervention proposed by the health-promoting school (HPS) model. The objectives are to understand whether the HPS model influenced the vision screening results and the attitude, knowledge level, and vision care behavior of the students involved. A prospective cohort study design was used to evaluate a vision health program. Four elementary schools, local education authorities, and one university in northern Taiwan established a coalition partnership to design a six-month program to combat myopia among students. The target population was 6668 school children from local elementary schools. For the purpose of this study, the outcome of visual acuity testing (in logMAR) was analyzed with a sampling of 373 school children (aged 11-12 years old) who were chosen from high prevalence of poor vision classes. After the HPS program, the attitudes, behaviors, and knowledge levels of the school children regarding vision health were significantly improved. The pre-intervention mean logMAR of all participating students ( N = 373) was -.10, which increased to -.19 after the intervention. Analysis using the Wilcoxon signed-rank test showed that the logMAR value was significantly improved after the intervention ( t = 2.13, p < 0.05). Our findings highlight the relevance and effectiveness of the coalition's efforts, which reinforces the usefulness of co-operatively implementing the HPS program.

  8. A Low-Power High-Speed Smart Sensor Design for Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Fang, Wai-Chi

    1997-01-01

    A low-power high-speed smart sensor system based on a large format active pixel sensor (APS) integrated with a programmable neural processor for space exploration missions is presented. The concept of building an advanced smart sensing system is demonstrated by a system-level microchip design that is composed with an APS sensor, a programmable neural processor, and an embedded microprocessor in a SOI CMOS technology. This ultra-fast smart sensor system-on-a-chip design mimics what is inherent in biological vision systems. Moreover, it is programmable and capable of performing ultra-fast machine vision processing in all levels such as image acquisition, image fusion, image analysis, scene interpretation, and control functions. The system provides about one tera-operation-per-second computing power which is a two order-of-magnitude increase over that of state-of-the-art microcomputers. Its high performance is due to massively parallel computing structures, high data throughput rates, fast learning capabilities, and advanced VLSI system-on-a-chip implementation.

  9. The accomplishments of the global initiative VISION 2020: The Right to Sight and the focus for the next 8 years of the campaign

    PubMed Central

    Ackland, Peter

    2012-01-01

    In the first 12 years of VISION 2020 sound programmatic approaches have been developed that are capable of delivering equitable eye health services to even the most remote and impoverished communities. A body of evidence around the economic arguments for investment in eye health has been developed that has fuelled successful advocacy work resulting in supportive high level policy statements. More than a 100 national plans to achieve the elimination of avoidable blindness have been developed and some notable contributions made from the corporate and government sectors to resource eye health programs. Good progress has been made to control infectious blinding diseases and at the very least there is anecdotal evidence to suggest that the global increase in the prevalence of blindness and visual impairment has been reversed in recent years, despite the ever increasing and more elderly global population. However if we are to achieve the goal of VISION 2020 we require a considerable scaling up of current efforts–this will depend on our future success in two key areas: i) Successful advocacy and engagement at individual country level to secure significantly enhanced national government commitment to financing their own VISION 2020 plans.ii) A new approach to VISION 2020 thinking that integrates eye health into health system development and develops new partnerships with wider health development initiatives. PMID:22944746

  10. Perceived overprotection: support gone bad?

    PubMed

    Cimarolli, Verena R; Reinhardt, Joann P; Horowitz, Amy

    2006-01-01

    This article focuses on the effects of perceived overprotection, a potentially problematic aspect of receiving support, on the ability to adjust to a chronic impairment, specifically, age-related vision loss. Perceived overprotection is an especially critical issue in this population of chronically ill older adults because of the safety issues associated with vision impairment and because perceptions on the part of the older adult that the support providers are overprotective may lead to excess disability. Participants were 584 older men and women with age-related vision impairment who applied for services at a vision rehabilitation agency. Path analysis was used to examine the effects of perceived overprotection on two positive indicators of adjustment: vision-specific adaptation and environmental mastery. Moreover, antecedents of perceived overprotection were examined. Higher levels of perceived overprotection were associated with less optimal adjustment to age-related vision loss, with lower scores on measures of vision-specific adaptation and environmental mastery. Higher levels of functional disability and instrumental support received were associated with higher levels of perceived overprotection. Findings indicate that support providers of older adults with visual impairment as well as vision rehabilitation service providers need to be aware of the detrimental impact of perceived overprotection.

  11. Comparative analysis of visual outcomes with 4 intraocular lenses: Monofocal, multifocal, and extended range of vision.

    PubMed

    Pedrotti, Emilio; Carones, Francesco; Aiello, Francesco; Mastropasqua, Rodolfo; Bruni, Enrico; Bonacci, Erika; Talli, Pietro; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2018-02-01

    To compare the visual acuity, refractive outcomes, and quality of vision in patients with bilateral implantation of 4 intraocular lenses (IOLs). Department of Neurosciences, Biomedicine and Movement Sciences, Eye Clinic, University of Verona, Verona, and Carones Ophthalmology Center, Milano, Italy. Prospective case series. The study included patients who had bilateral cataract surgery with the implantation of 1 of 4 IOLs as follows: Tecnis 1-piece monofocal (monofocal IOL), Tecnis Symfony extended range of vision (extended-range-of-vision IOL), Restor +2.5 diopter (D) (+2.5 D multifocal IOL), and Restor +3.0 D (+3.0 D multifocal IOL). Visual acuity, refractive outcome, defocus curve, objective optical quality, contrast sensitivity, spectacle independence, and glare perception were evaluated 6 months after surgery. The study comprised 185 patients. The extended-range-of-vision IOL (55 patients) showed better distance visual outcomes than the monofocal IOL (30 patients) and high-addition apodized diffractive-refractive multifocal IOLs (P ≤ .002). The +3.0 D multifocal IOL (50 patients) showed the best near visual outcomes (P < .001). The +2.5 D multifocal IOL (50 patients) and extended-range-of-vision IOL provided significantly better intermediate visual outcomes than the other 2 IOLs, with significantly better vision for a defocus level of -1.5 D (P < .001). Better spectacle independence was shown for the +2.5 D multifocal IOL and extended-range-of-vision IOL (P < .001). The extended-range-of-vision IOL and +2.5 D multifocal IOL provided significantly better intermediate visual restoration after cataract surgery than the monofocal IOL and +3.0 D multifocal IOL, with significantly better quality of vision with the extended-range-of-vision IOL. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. The Relationship Between CO2 Levels and CO2 Related Symptoms Reported on the ISS

    NASA Technical Reports Server (NTRS)

    VanBaalen, M.; Law, J.; Foy, M.; Wear, M. L.; Mason, S.; Mendez, C.; Meyers, V.

    2014-01-01

    Medical Operations, Toxicology, and the Lifetime Surveillance of Astronaut Health collaborated to assess the association of CO2 levels on board the International Space Station and USOS crew reported symptoms inflight, i.e. headache and vision changes. Private Medical Conference (PMC) documents and the weekly Space Medicine Operations Team (SMOT) Notes were used to provide a robust data set of inflight medical events. All events and non-events were documented independent of CO2 levels and other potential contributors. Average (arithmetic mean) and single point maximum ppCO2 was calculated for the 24 hours and 7 days prior to the PMC or SMOT date and time provided by LSAH. Observations falling within the first 7 days of flight (147) were removed from the datasets analyzed to avoid confounding with Space Adaptation Syndrome. The final analysis was based on 1716 observations. For headache, 46 headaches were observed. CO2 level, age at launch, time inflight, and data source were all significantly associated with headache. In particular, for each 1 mmHg increase in CO2, the odds of a crewmember reporting a headache doubled. For vision changes, 29 reports of vision changes were observed. These observations were not found to be statistically associated with CO2 levels as analyzed. While the incidence of headache has was not high (3%), headaches may be an indicator of underlying increases in intracranial pressure, which may result likely from the synergy between CO2-induced cerebral vasodilatation and decreased venous drainage in microgravity. Vision changes were inconsistently reported and as a result did not align appropriately with the CO2 levels. Further analysis is needed. Our results support ongoing efforts to lower the CO2 exposure limits in spacecraft.

  13. Thoughts turned into high-level commands: Proof-of-concept study of a vision-guided robot arm driven by functional MRI (fMRI) signals.

    PubMed

    Minati, Ludovico; Nigri, Anna; Rosazza, Cristina; Bruzzone, Maria Grazia

    2012-06-01

    Previous studies have demonstrated the possibility of using functional MRI to control a robot arm through a brain-machine interface by directly coupling haemodynamic activity in the sensory-motor cortex to the position of two axes. Here, we extend this work by implementing interaction at a more abstract level, whereby imagined actions deliver structured commands to a robot arm guided by a machine vision system. Rather than extracting signals from a small number of pre-selected regions, the proposed system adaptively determines at individual level how to map representative brain areas to the input nodes of a classifier network. In this initial study, a median action recognition accuracy of 90% was attained on five volunteers performing a game consisting of collecting randomly positioned coloured pawns and placing them into cups. The "pawn" and "cup" instructions were imparted through four mental imaginery tasks, linked to robot arm actions by a state machine. With the current implementation in MatLab language the median action recognition time was 24.3s and the robot execution time was 17.7s. We demonstrate the notion of combining haemodynamic brain-machine interfacing with computer vision to implement interaction at the level of high-level commands rather than individual movements, which may find application in future fMRI approaches relevant to brain-lesioned patients, and provide source code supporting further work on larger command sets and real-time processing. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Predictors of vision impairment in Multiple Sclerosis.

    PubMed

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  15. Progress in high-level exploratory vision

    NASA Astrophysics Data System (ADS)

    Brand, Matthew

    1993-08-01

    We have been exploring the hypothesis that vision is an explanatory process, in which causal and functional reasoning about potential motion plays an intimate role in mediating the activity of low-level visual processes. In particular, we have explored two of the consequences of this view for the construction of purposeful vision systems: Causal and design knowledge can be used to (1) drive focus of attention, and (2) choose between ambiguous image interpretations. An important result of visual understanding is an explanation of the scene's causal structure: How action is originated, constrained, and prevented, and what will happen in the immediate future. In everyday visual experience, most action takes the form of motion, and most causal analysis takes the form of dynamical analysis. This is even true of static scenes, where much of a scene's interest lies in how possible motions are arrested. This paper describes our progress in developing domain theories and visual processes for the understanding of various kinds of structured scenes, including structures built out of children's constructive toys and simple mechanical devices.

  16. Real-time tracking using stereo and motion: Visual perception for space robotics

    NASA Technical Reports Server (NTRS)

    Nishihara, H. Keith; Thomas, Hans; Huber, Eric; Reid, C. Ann

    1994-01-01

    The state-of-the-art in computing technology is rapidly attaining the performance necessary to implement many early vision algorithms at real-time rates. This new capability is helping to accelerate progress in vision research by improving our ability to evaluate the performance of algorithms in dynamic environments. In particular, we are becoming much more aware of the relative stability of various visual measurements in the presence of camera motion and system noise. This new processing speed is also allowing us to raise our sights toward accomplishing much higher-level processing tasks, such as figure-ground separation and active object tracking, in real-time. This paper describes a methodology for using early visual measurements to accomplish higher-level tasks; it then presents an overview of the high-speed accelerators developed at Teleos to support early visual measurements. The final section describes the successful deployment of a real-time vision system to provide visual perception for the Extravehicular Activity Helper/Retriever robotic system in tests aboard NASA's KC135 reduced gravity aircraft.

  17. Contrasting the use of 2 vision-specific quality of life questionnaires in subjects with open-angle glaucoma.

    PubMed

    Wren, Patricia A; Musch, David C; Janz, Nancy K; Niziol, Leslie M; Guire, Kenneth E; Gillespie, Brenda W

    2009-01-01

    To compare 2 vision-specific functional status measures to each other and to clinical parameters in the Collaborative Initial Glaucoma Treatment Study (CIGTS). CIGTS participants completed the Visual Activities Questionnaire (VAQ) and the National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and were tested for visual field (VF) and visual acuity (VA). In all, 426 subjects contributed the VAQ and NEI-VFQ scores at 54 months. Pearson correlations were used to assess associations. The VAQ subscales (range, 0 to 100) that assessed light-dark adaptation (mean=66.1), glare disability (66.4), and acuity/spatial vision (67.7) indicated vision-related functions that CIGTS participants found most difficult. On the NEI-VFQ, subjects reported high levels of visual functioning, with mean >/=90 (out of 100) on the total score and in 9 of 12 subscales. General vision (mean=82.6) received the lowest subscale score. Two subscales common to both questionnaires were highly correlated: VA (r=0.68) and peripheral vision (r=0.77) (both P<0.0001). Correlations between participants' perceptions and clinical measures of visual function were in the expected direction, but weaker. Stronger associations were found between clinical measures and the NEI-VFQ than the VAQ. Better eye VF and worse eye VA had the highest number of significant correlations with subjects' perceptions of their visual function. Increasing VF loss was associated with a significant decrease in the overall and peripheral vision subscale scores from both questionnaires, and also several other subscales. CIGTS patients reported excellent visual function on both the NEI-VFQ and VAQ. These findings will help researchers interested in assessing patients' perceptions of their visual function make an informed selection when choosing between the VAQ and the NEI-VFQ.

  18. Prevalence of, and risk factors for, presenting visual impairment: findings from a vision screening programme based on UK NSC guidance in a multi-ethnic population.

    PubMed

    Bruce, Alison; Santorelli, Gillian; Wright, John; Bradbury, John; Barrett, Brendan T; Bloj, Marina; Sheldon, Trevor A

    2018-06-13

    To determine presenting visual acuity levels and explore the factors associated with failing vision screening in a multi-ethnic population of UK children aged 4-5 years. Visual acuity (VA) using the logMAR Crowded Test was measured in 16,541 children in a population-based vision screening programme. Referral for cycloplegic examination was based on national recommendations (>0.20logMAR in one or both eyes). Presenting visual impairment (PVI) was defined as VA >0.3logMAR in the better eye. Multivariable logistic regression was used to assess the association of ethnicity, maternal, and early-life factors with failing vision screening and PVI in participants of the Born in Bradford birth cohort. In total, 2467/16,541 (15%) failed vision screening, 732 (4.4%) had PVI. Children of Pakistani (OR: 2.49; 95% CI: 1.74-3.60) and other ethnicities (OR: 2.00; 95% CI: 1.28-3.12) showed increased odds of PVI compared to white children. Children born to older mothers (OR: 1.63; 95% CI: 1.19-2.24) and of low birth weight (OR: 1.52; 95% CI: 1.00-2.34) also showed increased odds. Follow-up results were available for 1068 (43.3%) children, 993 (93%) were true positives; 932 (94%) of these had significant refractive error. Astigmatism (>1DC) (44%) was more common in children of Pakistani ethnicity and hypermetropia (>3.0DS) (27%) in white children (Fisher's exact, p < 0.001). A high prevalence of PVI is reported. Failing vision screening and PVI were highly associated with ethnicity. The positive predictive value of the vision screening programme was good, with only 7% of children followed up confirmed as false positives.

  19. Barriers to accessing low vision services.

    PubMed

    Pollard, Tamara L; Simpson, John A; Lamoureux, Ecosse L; Keeffe, Jill E

    2003-07-01

    To investigate barriers to accessing low vision services in Australia. Adults with a vision impairment (<6/12 in the better eye and/or significant visual field defect), who were current patients at the Royal Victorian Eye and Ear Hospital (RVEEH), were interviewed. The questions investigated self-perceived vision difficulties, duration of vision loss and satisfaction with vision and also examined issues of awareness of low vision services and referral to services. Focus groups were also conducted with vision impaired (<6/12 in the better eye) patients from the RVEEH, listeners of the Radio for the Print Handicapped and peer workers at Vision Australia Foundation. The discussions were recorded and transcribed. The questionnaire revealed that referral to low vision services was associated with a greater degree of vision loss (p = 0.002) and a greater self-perception of low vision (p = 0.005) but that referral was not associated with satisfaction (p = 0.144) or difficulties related to vision (p = 0.169). Participants with mild and moderate vision impairment each reported similar levels of difficulties with daily activities and satisfaction with their vision (p > 0.05). However, there was a significant difference in the level of difficulties experienced with daily activities between those with mild-moderate and severe vision impairment (p < 0.05). The participants of the focus groups identified barriers to accessing low vision services related to awareness of services among the general public and eye care professionals, understanding of low vision and the services available, acceptance of low vision, the referral process, and transport. In addition to the expected difficulties with lack of awareness of services by people with low vision, many people do not understand what the services provide and do not identify themselves as having low vision. Knowledge of these barriers, from the perspective of people with low vision, can now be used to guide the development and content of future health-promotion campaigns.

  20. An embedded vision system for an unmanned four-rotor helicopter

    NASA Astrophysics Data System (ADS)

    Lillywhite, Kirt; Lee, Dah-Jye; Tippetts, Beau; Fowers, Spencer; Dennis, Aaron; Nelson, Brent; Archibald, James

    2006-10-01

    In this paper an embedded vision system and control module is introduced that is capable of controlling an unmanned four-rotor helicopter and processing live video for various law enforcement, security, military, and civilian applications. The vision system is implemented on a newly designed compact FPGA board (Helios). The Helios board contains a Xilinx Virtex-4 FPGA chip and memory making it capable of implementing real time vision algorithms. A Smooth Automated Intelligent Leveling daughter board (SAIL), attached to the Helios board, collects attitude and heading information to be processed in order to control the unmanned helicopter. The SAIL board uses an electrolytic tilt sensor, compass, voltage level converters, and analog to digital converters to perform its operations. While level flight can be maintained, problems stemming from the characteristics of the tilt sensor limits maneuverability of the helicopter. The embedded vision system has proven to give very good results in its performance of a number of real-time robotic vision algorithms.

  1. Depression and experience of vision loss in group of adults in rehabilitation setting: mixed-methods pilot study.

    PubMed

    Senra, Hugo; Vieira, Cristina R; Nicholls, Elizabeth G; Leal, Isabel

    2013-01-01

    There is a paucity of literature regarding the relationship between the experience of vision loss and depression. Therefore, the current pilot study aimed to explore whether significant differences existed in levels of depression between adults with different vision loss experiences. A group of adults aged between 20 and 65 yr old with irreversible vision loss in a rehabilitation setting was interviewed. Semistructured interviews were conducted in order to explore patients' experience of vision loss. The Center for Epidemiologic Studies Depression Scale (CES-D) was used to assess depressive levels; 39.5% (n = 15) of patients met CES-D criteria for depression. In addition, higher levels of depression (p < 0.05) were identified in patients whose interviews revealed greater self-awareness of impairment, inadequate social support, and longer rehabilitation stay. Current findings draw attention to variables such as self-awareness of impairment and perceived social support and suggest that depression following vision loss may be related to patients' emotional experiences of impairment and adjustment processes.

  2. Hierarchical layered and semantic-based image segmentation using ergodicity map

    NASA Astrophysics Data System (ADS)

    Yadegar, Jacob; Liu, Xiaoqing

    2010-04-01

    Image segmentation plays a foundational role in image understanding and computer vision. Although great strides have been made and progress achieved on automatic/semi-automatic image segmentation algorithms, designing a generic, robust, and efficient image segmentation algorithm is still challenging. Human vision is still far superior compared to computer vision, especially in interpreting semantic meanings/objects in images. We present a hierarchical/layered semantic image segmentation algorithm that can automatically and efficiently segment images into hierarchical layered/multi-scaled semantic regions/objects with contextual topological relationships. The proposed algorithm bridges the gap between high-level semantics and low-level visual features/cues (such as color, intensity, edge, etc.) through utilizing a layered/hierarchical ergodicity map, where ergodicity is computed based on a space filling fractal concept and used as a region dissimilarity measurement. The algorithm applies a highly scalable, efficient, and adaptive Peano- Cesaro triangulation/tiling technique to decompose the given image into a set of similar/homogenous regions based on low-level visual cues in a top-down manner. The layered/hierarchical ergodicity map is built through a bottom-up region dissimilarity analysis. The recursive fractal sweep associated with the Peano-Cesaro triangulation provides efficient local multi-resolution refinement to any level of detail. The generated binary decomposition tree also provides efficient neighbor retrieval mechanisms for contextual topological object/region relationship generation. Experiments have been conducted within the maritime image environment where the segmented layered semantic objects include the basic level objects (i.e. sky/land/water) and deeper level objects in the sky/land/water surfaces. Experimental results demonstrate the proposed algorithm has the capability to robustly and efficiently segment images into layered semantic objects/regions with contextual topological relationships.

  3. High dynamic range vision sensor for automotive applications

    NASA Astrophysics Data System (ADS)

    Grenet, Eric; Gyger, Steve; Heim, Pascal; Heitger, Friedrich; Kaess, Francois; Nussbaum, Pascal; Ruedi, Pierre-Francois

    2005-02-01

    A 128 x 128 pixels, 120 dB vision sensor extracting at the pixel level the contrast magnitude and direction of local image features is used to implement a lane tracking system. The contrast representation (relative change of illumination) delivered by the sensor is independent of the illumination level. Together with the high dynamic range of the sensor, it ensures a very stable image feature representation even with high spatial and temporal inhomogeneities of the illumination. Dispatching off chip image feature is done according to the contrast magnitude, prioritizing features with high contrast magnitude. This allows to reduce drastically the amount of data transmitted out of the chip, hence the processing power required for subsequent processing stages. To compensate for the low fill factor (9%) of the sensor, micro-lenses have been deposited which increase the sensitivity by a factor of 5, corresponding to an equivalent of 2000 ASA. An algorithm exploiting the contrast representation output by the vision sensor has been developed to estimate the position of a vehicle relative to the road markings. The algorithm first detects the road markings based on the contrast direction map. Then, it performs quadratic fits on selected kernel of 3 by 3 pixels to achieve sub-pixel accuracy on the estimation of the lane marking positions. The resulting precision on the estimation of the vehicle lateral position is 1 cm. The algorithm performs efficiently under a wide variety of environmental conditions, including night and rainy conditions.

  4. Subjective figures and texture perception.

    PubMed

    Zucker, S W; Cavanagh, P

    1985-01-01

    A texture discrimination task using the Ehrenstein illusion demonstrates that subjective brightness effects can play an essential role in early vision. The subjectively bright regions of the Ehrenstein can be organized either as discs or as stripes, depending on orientation. The accuracy of discrimination between variants of the Ehrenstein and control patterns was a direct function of the presence of the illusory brightness stripes, being high when they were present and low otherwise. It is argued that neither receptive field structure nor spatial-frequency content can adequately account for these results. We suggest that the subjective brightness illusions, rather than being a high-level, cognitive aspect of vision, are in fact the result of an early visual process.

  5. Insights into Inpatients with Poor Vision: A High Value Proposition

    PubMed Central

    Press, Valerie G.; Matthiesen, Madeleine I.; Ranadive, Alisha; Hariprasad, Seenu M.; Meltzer, David O.; Arora, Vineet M.

    2015-01-01

    Background Vision impairment is an under-recognized risk factor for adverse events among hospitalized patients, yet vision is neither routinely tested nor documented for inpatients. Low-cost ($8 and up) non-prescription ‘readers’ may be a simple, high-value intervention to improve inpatients’ vision. We aimed to study initial feasibility and efficacy of screening and correcting inpatients’ vision. Methods From June 2012 through January 2014 we began testing whether participants’ vision corrected with non-prescription lenses for eligible participants failing a vision screen (Snellen chart) performed by research assistants (RAs). Descriptive statistics and tests of comparison, including t-tests and chi-squared tests, were used when appropriate. All analyses were performed using Stata version 12 (StataCorps, College Station, TX). Results Over 800 participants’ vision was screened (n=853). Older (≥65 years; 56%) participants were more likely to have insufficient vision than younger (<65 years; 28%; p<0.001). Non-prescription readers corrected the majority of eligible participants’ vision (82%, 95/116). Discussion Among an easily identified sub-group of inpatients with poor vision, low-cost ‘readers’ successfully corrected most participants’ vision. Hospitalists and other clinicians working in the inpatient setting can play an important role in identifying opportunities to provide high-value care related to patients’ vision. PMID:25755206

  6. Resource Letter CCV-1: Color and Color Vision.

    ERIC Educational Resources Information Center

    Stuewer, Roger H., Ed.; Pease, Paul L.

    1980-01-01

    Listed are selected resource materials on color vision and the measurement and specification of the stimulus for vision, photometry, and colorimetry. The author's purpose is to equip teachers and students with an understanding of normal and abnormal color vision. References are categorized relative to content level. (Author/DS)

  7. Wearable optical-digital assistive device for low vision students.

    PubMed

    Afinogenov, Boris I; Coles, James B; Parthasarathy, Sailashri; Press-Williams, Jessica; Tsykunova, Ralina; Vasilenko, Anastasia; Narain, Jaya; Hanumara, Nevan C; Winter, Amos; Satgunam, PremNandhini

    2016-08-01

    People with low vision have limited residual vision that can be greatly enhanced through high levels of magnification. Current assistive technologies are tailored for far field or near field magnification but not both. In collaboration with L.V. Prasad Eye Institute (LVPEI), a wearable, optical-digital assistive device was developed to meet the near and far field magnification needs of students. The critical requirements, system architecture and design decisions for each module were analyzed and quantified. A proof-of-concept prototype was fabricated that can achieve magnification up to 8x and a battery life of up to 8 hours. Potential user evaluation with a Snellen chart showed identification of characters not previously discernible. Further feedback suggested that the system could be used as a general accessibility aid.

  8. USC orthogonal multiprocessor for image processing with neural networks

    NASA Astrophysics Data System (ADS)

    Hwang, Kai; Panda, Dhabaleswar K.; Haddadi, Navid

    1990-07-01

    This paper presents the architectural features and imaging applications of the Orthogonal MultiProcessor (OMP) system, which is under construction at the University of Southern California with research funding from NSF and assistance from several industrial partners. The prototype OMP is being built with 16 Intel i860 RISC microprocessors and 256 parallel memory modules using custom-designed spanning buses, which are 2-D interleaved and orthogonally accessed without conflicts. The 16-processor OMP prototype is targeted to achieve 430 MIPS and 600 Mflops, which have been verified by simulation experiments based on the design parameters used. The prototype OMP machine will be initially applied for image processing, computer vision, and neural network simulation applications. We summarize important vision and imaging algorithms that can be restructured with neural network models. These algorithms can efficiently run on the OMP hardware with linear speedup. The ultimate goal is to develop a high-performance Visual Computer (Viscom) for integrated low- and high-level image processing and vision tasks.

  9. Integrated 3-D vision system for autonomous vehicles

    NASA Astrophysics Data System (ADS)

    Hou, Kun M.; Shawky, Mohamed; Tu, Xiaowei

    1992-03-01

    Nowadays, autonomous vehicles have become a multidiscipline field. Its evolution is taking advantage of the recent technological progress in computer architectures. As the development tools became more sophisticated, the trend is being more specialized, or even dedicated architectures. In this paper, we will focus our interest on a parallel vision subsystem integrated in the overall system architecture. The system modules work in parallel, communicating through a hierarchical blackboard, an extension of the 'tuple space' from LINDA concepts, where they may exchange data or synchronization messages. The general purpose processing elements are of different skills, built around 40 MHz i860 Intel RISC processors for high level processing and pipelined systolic array processors based on PLAs or FPGAs for low-level processing.

  10. The use of films to simulate age-related declines in yellow vision.

    PubMed

    Yoshida, C A; Sakuraba, S

    1996-06-01

    One of characteristics of normal age-related vision losses depends on yellow-intensity in the lens of the eye. (1) We investigated discrimination between seven intensities of yellow in 303 elderly people aged from late 60s to early 90s. The results demonstrated that the failures of vision increase with age, and the losses depend on yellow intensity. (2) We got a yellow index (YI) from different Y-intensity color charts used in (I) above, covering 12 kinds of marketable yellow films, and selected two kinds of films which match (YI) original color charts, corresponding to 53% or 89% of Y intensity. (3) Finally, we judged that all of these colors' xy-chromaticities with or without the two films, were exactly on the unique-yellow line in the diagram, which means a pure yellow, not mixed. (4) Then, these two films could simulate each of the mid-level or high-level Y intensity, respectively, in age-related vision. (5) We analyzed changes of all kinds of colors (220) in xy-chromaticity diagrams and obtained mean changing distances from every original chromatogram compared to the others. These data would be useful for architects or designers to design cities or buildings for use by the elderly.

  11. The mainstream is not electable: when vision triumphs over representativeness in leader emergence and effectiveness.

    PubMed

    Halevy, Nir; Berson, Yair; Galinsky, Adam D

    2011-07-01

    Theories of visionary leadership propose that groups bestow leadership on exceptional group members. In contrast, social identity perspectives claim that leadership arises, in part, from a person's ability to be seen as representative of the group. Integrating these perspectives, the authors propose that effective leaders often share group members' perspectives concerning the present, yet offer a unique and compelling vision for the group's future. In addition, although intergroup contexts may increase the value of representativeness, the authors predict that vision dominates representativeness in single-group situations characterized by high levels of collective stress (e.g., a natural disaster). Five studies demonstrated that visionary leaders (those who offer novel solutions to their group's predicament) attract more followers, promote group identification and intrinsic motivation, mobilize collective action, and effectively regulate group members' emotions and reactions to crises compared to representative leaders. The authors discuss when, why, and how vision triumphs over representativeness in leader emergence and effectiveness. © 2011 by the Society for Personality and Social Psychology, Inc

  12. A Biologically Realistic Cortical Model of Eye Movement Control in Reading

    ERIC Educational Resources Information Center

    Heinzle, Jakob; Hepp, Klaus; Martin, Kevan A. C.

    2010-01-01

    Reading is a highly complex task involving a precise integration of vision, attention, saccadic eye movements, and high-level language processing. Although there is a long history of psychological research in reading, it is only recently that imaging studies have identified some neural correlates of reading. Thus, the underlying neural mechanisms…

  13. Doing the Humanities: The Use of Undergraduate Classroom Humanities Research Projects.

    ERIC Educational Resources Information Center

    Geib, George W.

    "American Visions" is a freshman-level survey course offered by the Department of History as part of Butler University's core curriculum. The course is built around three primary contextual considerations: high culture, popular culture, and community culture. The high culture approach is designed to introduce students to major systems of thought…

  14. Dopamine Receptor DOP-4 Modulates Habituation to Repetitive Photoactivation of a "C. elegans" Polymodal Nociceptor

    ERIC Educational Resources Information Center

    Ardiel, Evan L.; Giles, Andrew C.; Yu, Alex J.; Lindsay, Theodore H.; Lockery, Shawn R.; Rankin, Catharine H.

    2016-01-01

    Habituation is a highly conserved phenomenon that remains poorly understood at the molecular level. Invertebrate model systems, like "Caenorhabditis elegans," can be a powerful tool for investigating this fundamental process. Here we established a high-throughput learning assay that used real-time computer vision software for behavioral…

  15. Oestrogen, ocular function and low-level vision: a review.

    PubMed

    Hutchinson, Claire V; Walker, James A; Davidson, Colin

    2014-11-01

    Over the past 10 years, a literature has emerged concerning the sex steroid hormone oestrogen and its role in human vision. Herein, we review evidence that oestrogen (oestradiol) levels may significantly affect ocular function and low-level vision, particularly in older females. In doing so, we have examined a number of vision-related disorders including dry eye, cataract, increased intraocular pressure, glaucoma, age-related macular degeneration and Leber's hereditary optic neuropathy. In each case, we have found oestrogen, or lack thereof, to have a role. We have also included discussion of how oestrogen-related pharmacological treatments for menopause and breast cancer can impact the pathology of the eye and a number of psychophysical aspects of vision. Finally, we have reviewed oestrogen's pharmacology and suggest potential mechanisms underlying its beneficial effects, with particular emphasis on anti-apoptotic and vascular effects. © 2014 Society for Endocrinology.

  16. Student Progress to Graduation in New York City High Schools: A Metric Designed by New Visions for Public Schools. Part I: Core Components

    ERIC Educational Resources Information Center

    Fairchild, Susan; Gunton, Brad; Donohue, Beverly; Berry, Carolyn; Genn, Ruth; Knevals, Jessica

    2011-01-01

    Students who achieve critical academic benchmarks such as high attendance rates, continuous levels of credit accumulation, and high grades have a greater likelihood of success throughout high school and beyond. However, keeping students on track toward meeting graduation requirements and quickly identifying students who are at risk of falling off…

  17. Braille Reading Accuracy of Students Who Are Visually Impaired: The Effects of Gender, Age at Vision Loss, and Level of Education

    ERIC Educational Resources Information Center

    Argyropoulos, Vassilis; Papadimitriou, Vassilios

    2015-01-01

    Introduction: The present study assesses the performance of students who are visually impaired (that is, those who are blind or have low vision) in braille reading accuracy and examines potential correlations among the error categories on the basis of gender, age at loss of vision, and level of education. Methods: Twenty-one visually impaired…

  18. Feature-Free Activity Classification of Inertial Sensor Data With Machine Vision Techniques: Method, Development, and Evaluation.

    PubMed

    Dominguez Veiga, Jose Juan; O'Reilly, Martin; Whelan, Darragh; Caulfield, Brian; Ward, Tomas E

    2017-08-04

    Inertial sensors are one of the most commonly used sources of data for human activity recognition (HAR) and exercise detection (ED) tasks. The time series produced by these sensors are generally analyzed through numerical methods. Machine learning techniques such as random forests or support vector machines are popular in this field for classification efforts, but they need to be supported through the isolation of a potentially large number of additionally crafted features derived from the raw data. This feature preprocessing step can involve nontrivial digital signal processing (DSP) techniques. However, in many cases, the researchers interested in this type of activity recognition problems do not possess the necessary technical background for this feature-set development. The study aimed to present a novel application of established machine vision methods to provide interested researchers with an easier entry path into the HAR and ED fields. This can be achieved by removing the need for deep DSP skills through the use of transfer learning. This can be done by using a pretrained convolutional neural network (CNN) developed for machine vision purposes for exercise classification effort. The new method should simply require researchers to generate plots of the signals that they would like to build classifiers with, store them as images, and then place them in folders according to their training label before retraining the network. We applied a CNN, an established machine vision technique, to the task of ED. Tensorflow, a high-level framework for machine learning, was used to facilitate infrastructure needs. Simple time series plots generated directly from accelerometer and gyroscope signals are used to retrain an openly available neural network (Inception), originally developed for machine vision tasks. Data from 82 healthy volunteers, performing 5 different exercises while wearing a lumbar-worn inertial measurement unit (IMU), was collected. The ability of the proposed method to automatically classify the exercise being completed was assessed using this dataset. For comparative purposes, classification using the same dataset was also performed using the more conventional approach of feature-extraction and classification using random forest classifiers. With the collected dataset and the proposed method, the different exercises could be recognized with a 95.89% (3827/3991) accuracy, which is competitive with current state-of-the-art techniques in ED. The high level of accuracy attained with the proposed approach indicates that the waveform morphologies in the time-series plots for each of the exercises is sufficiently distinct among the participants to allow the use of machine vision approaches. The use of high-level machine learning frameworks, coupled with the novel use of machine vision techniques instead of complex manually crafted features, may facilitate access to research in the HAR field for individuals without extensive digital signal processing or machine learning backgrounds. ©Jose Juan Dominguez Veiga, Martin O'Reilly, Darragh Whelan, Brian Caulfield, Tomas E Ward. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 04.08.2017.

  19. Feature-Free Activity Classification of Inertial Sensor Data With Machine Vision Techniques: Method, Development, and Evaluation

    PubMed Central

    O'Reilly, Martin; Whelan, Darragh; Caulfield, Brian; Ward, Tomas E

    2017-01-01

    Background Inertial sensors are one of the most commonly used sources of data for human activity recognition (HAR) and exercise detection (ED) tasks. The time series produced by these sensors are generally analyzed through numerical methods. Machine learning techniques such as random forests or support vector machines are popular in this field for classification efforts, but they need to be supported through the isolation of a potentially large number of additionally crafted features derived from the raw data. This feature preprocessing step can involve nontrivial digital signal processing (DSP) techniques. However, in many cases, the researchers interested in this type of activity recognition problems do not possess the necessary technical background for this feature-set development. Objective The study aimed to present a novel application of established machine vision methods to provide interested researchers with an easier entry path into the HAR and ED fields. This can be achieved by removing the need for deep DSP skills through the use of transfer learning. This can be done by using a pretrained convolutional neural network (CNN) developed for machine vision purposes for exercise classification effort. The new method should simply require researchers to generate plots of the signals that they would like to build classifiers with, store them as images, and then place them in folders according to their training label before retraining the network. Methods We applied a CNN, an established machine vision technique, to the task of ED. Tensorflow, a high-level framework for machine learning, was used to facilitate infrastructure needs. Simple time series plots generated directly from accelerometer and gyroscope signals are used to retrain an openly available neural network (Inception), originally developed for machine vision tasks. Data from 82 healthy volunteers, performing 5 different exercises while wearing a lumbar-worn inertial measurement unit (IMU), was collected. The ability of the proposed method to automatically classify the exercise being completed was assessed using this dataset. For comparative purposes, classification using the same dataset was also performed using the more conventional approach of feature-extraction and classification using random forest classifiers. Results With the collected dataset and the proposed method, the different exercises could be recognized with a 95.89% (3827/3991) accuracy, which is competitive with current state-of-the-art techniques in ED. Conclusions The high level of accuracy attained with the proposed approach indicates that the waveform morphologies in the time-series plots for each of the exercises is sufficiently distinct among the participants to allow the use of machine vision approaches. The use of high-level machine learning frameworks, coupled with the novel use of machine vision techniques instead of complex manually crafted features, may facilitate access to research in the HAR field for individuals without extensive digital signal processing or machine learning backgrounds. PMID:28778851

  20. Safety impacts of reduced visibility in inclement weather.

    DOT National Transportation Integrated Search

    2017-04-04

    This research seeks to better understand the ramifications of inclement weather on safety from a perspective of visibility. Visibility conditions at the time of a crash are rarely documented at a high level of detail. While vision is a key component ...

  1. Pyramidal neurovision architecture for vision machines

    NASA Astrophysics Data System (ADS)

    Gupta, Madan M.; Knopf, George K.

    1993-08-01

    The vision system employed by an intelligent robot must be active; active in the sense that it must be capable of selectively acquiring the minimal amount of relevant information for a given task. An efficient active vision system architecture that is based loosely upon the parallel-hierarchical (pyramidal) structure of the biological visual pathway is presented in this paper. Although the computational architecture of the proposed pyramidal neuro-vision system is far less sophisticated than the architecture of the biological visual pathway, it does retain some essential features such as the converging multilayered structure of its biological counterpart. In terms of visual information processing, the neuro-vision system is constructed from a hierarchy of several interactive computational levels, whereupon each level contains one or more nonlinear parallel processors. Computationally efficient vision machines can be developed by utilizing both the parallel and serial information processing techniques within the pyramidal computing architecture. A computer simulation of a pyramidal vision system for active scene surveillance is presented.

  2. Office of Biological and Physical Research: Overview Transitioning to the Vision for Space Exploration

    NASA Technical Reports Server (NTRS)

    Crouch, Roger

    2004-01-01

    Viewgraphs on NASA's transition to its vision for space exploration is presented. The topics include: 1) Strategic Directives Guiding the Human Support Technology Program; 2) Progressive Capabilities; 3) A Journey to Inspire, Innovate, and Discover; 4) Risk Mitigation Status Technology Readiness Level (TRL) and Countermeasures Readiness Level (CRL); 5) Biological And Physical Research Enterprise Aligning With The Vision For U.S. Space Exploration; 6) Critical Path Roadmap Reference Missions; 7) Rating Risks; 8) Current Critical Path Roadmap (Draft) Rating Risks: Human Health; 9) Current Critical Path Roadmap (Draft) Rating Risks: System Performance/Efficiency; 10) Biological And Physical Research Enterprise Efforts to Align With Vision For U.S. Space Exploration; 11) Aligning with the Vision: Exploration Research Areas of Emphasis; 12) Code U Efforts To Align With The Vision For U.S. Space Exploration; 13) Types of Critical Path Roadmap Risks; and 14) ISS Human Support Systems Research, Development, and Demonstration. A summary discussing the vision for U.S. space exploration is also provided.

  3. Color universal design: analysis of color category dependency on color vision type (3)

    NASA Astrophysics Data System (ADS)

    Kojima, Natsuki; Ichihara, Yasuyo G.; Ikeda, Tomohiro; Kamachi, Miyuki G.; Ito, Kei

    2012-01-01

    We report on the results of a study investigating the color perception characteristics of people with red-green color confusion. We believe that this is an important step towards achieving Color Universal Design. In Japan, approximately 5% of men and 0.2% of women have red-green confusion. The percentage for men is higher in Europe and the United States; up to 8% in some countries. Red-green confusion involves a perception of colors different from normal color vision. Colors are used as a means of disseminating clear information to people; however, it may be difficult to convey the correct information to people who have red-green confusion. Consequently, colors should be chosen that minimize accidents and that promote more effective communication. In a previous survey, we investigated color categories common to each color vision type, trichromat (C-type color vision), protan (P-type color vision) and deuteran (D-type color vision). In the present study, first, we conducted experiments in order to verify a previous survey of C-type color vision and P-type color vision. Next, we investigated color difference levels within "CIE 1976 L*a*b*" (the CIELAB uniform color space), where neither C-type nor P-type color vision causes accidents under certain conditions (rain maps/contour line levels and graph color legend levels). As a result, we propose a common chromaticity of colors that the two color vision types are able to categorize by means of color names common to C-type color vision. We also offer a proposal to explain perception characteristics of color differences with normal color vision and red-green confusion using the CIELAB uniform color space. This report is a follow-up to SPIE-IS & T / Vol. 7528 7528051-8 and SPIE-IS & T /vol. 7866 78660J-1-8.

  4. Visual evoked potentials through night vision goggles.

    PubMed

    Rabin, J

    1994-04-01

    Night vision goggles (NVG's) have widespread use in military and civilian environments. NVG's amplify ambient illumination making performance possible when there is insufficient illumination for normal vision. While visual performance through NVG's is commonly assessed by measuring threshold functions such as visual acuity, few attempts have been made to assess vision through NVG's at suprathreshold levels of stimulation. Such information would be useful to better understand vision through NVG's across a range of stimulus conditions. In this study visual evoked potentials (VEP's) were used to evaluate vision through NVG's across a range of stimulus contrasts. The amplitude and latency of the VEP varied linearly with log contrast. A comparison of VEP's recorded with and without NVG's was used to estimate contrast attenuation through the device. VEP's offer an objective, electrophysiological tool to assess visual performance through NVG's at both threshold and suprathreshold levels of visual stimulation.

  5. Reliable vision-guided grasping

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1992-01-01

    Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

  6. Reduced vision in highly myopic eyes without ocular pathology: the ZOC-BHVI high myopia study.

    PubMed

    Jong, Monica; Sankaridurg, Padmaja; Li, Wayne; Resnikoff, Serge; Naidoo, Kovin; He, Mingguang

    2018-01-01

    The aim was to investigate the relationship of the magnitude of myopia with visual acuity in highly myopic eyes without ocular pathology. Twelve hundred and ninety-two highly myopic eyes (up to -6.00 DS both eyes, no astigmatic cut-off) with no ocular pathology from the ZOC-BHVI high myopia study in China, had cycloplegic refraction, followed by subjective refraction and visual acuities and axial length measurement. Two logistic regression models were undertaken to test the association of age, gender, refractive error, axial length and parental myopia with reduced vision. Mean group age was 19.0 ± 8.6 years; subjective spherical equivalent refractive error was -9.03 ± 2.73 D; objective spherical equivalent refractive error was -8.90 ± 2.60 D and axial length was 27.0 ± 1.3 mm. Using visual acuity, 82.4 per cent had normal vision, 16.0 per cent had mildly reduced vision, 1.2 per cent had moderately reduced vision, 0.3 per cent had severely reduced vision and no subjects were blind. The percentage with reduced vision increased with spherical equivalent to 74.5 per cent from -15.00 to -39.99 D, axial length to 67.7 per cent of eyes from 30.01 to 32.00 mm and age to 22.9 per cent of those 41 years and over. Spherical equivalent and axial length were significantly associated with reduced vision (p < 0.0001). Age and parental myopia were not significantly associated with reduced vision. Gender was significant for one model (p = 0.04). Mildly reduced vision is common in high myopia without ocular pathology and is strongly correlated with greater magnitudes of refractive error and axial length. Better understanding is required to minimise reduced vision in high myopes. © 2017 Optometry Australia.

  7. [Integrated approach to the promotion of young academics in vision research at a European level].

    PubMed

    Wheeler-Schilling, T H; Zrenner, E; Schiefer, U

    2006-02-01

    The European Commission predicts a dramatic dearth of researchers and doctors in the near future. At the same time, highly qualified and motivated human resources form the only guarantee for further development of scientific knowledge for research and clinical application. This situation calls for an integrated approach to the promotion of young academics in vision research at a European level. The Marie Curie Program of the European Union is an ideal tool, which can be used particularly efficiently in vision research to promote international networking and dedicated advancement of young academics. The exemplary chances and opportunities of this strategy can be demonstrated by six specific measures of the University Eye Hospital in Tübingen. In particular, strictly defined medical areas will need to fully exploit their innovation potential in the future in order to secure their position in the global research area or even to expand it. New organizational concepts and long-term career options as well as a clear commitment to cutting-edge performance are the prerequisites for effective promotion of young academics.

  8. Family planning and family vision in mothers after diagnosis of a child with autism spectrum disorder

    PubMed Central

    Navot, Noa; Jorgenson, Alicia Grattan; Stoep, Ann Vander; Toth, Karen; Webb, Sara Jane

    2016-01-01

    The diagnosis of a child with autism has short- and long-term impacts on family functioning. With early diagnosis, the diagnostic process is likely to co-occur with family planning decisions, yet little is known about how parents navigate this process. This study explores family planning decision making process among mothers of young children with autism spectrum disorder in the United States, by understanding the transformation in family vision before and after the diagnosis. A total of 22 mothers of first born children, diagnosed with autism between 2 and 4 years of age, were interviewed about family vision prior to and after their child’s diagnosis. Grounded Theory method was used for data analysis. Findings indicated that coherence of early family vision, maternal cognitive flexibility, and maternal responses to diagnosis were highly influential in future family planning decisions. The decision to have additional children reflected a high level of adaptability built upon a solid internalized family model and a flexible approach to life. Decision to stop childrearing reflected a relatively less coherent family model and more rigid cognitive style followed by ongoing hardship managing life after the diagnosis. This report may be useful for health-care providers in enhancing therapeutic alliance and guiding family planning counseling. PMID:26395237

  9. Family planning and family vision in mothers after diagnosis of a child with autism spectrum disorder.

    PubMed

    Navot, Noa; Jorgenson, Alicia Grattan; Vander Stoep, Ann; Toth, Karen; Webb, Sara Jane

    2016-07-01

    The diagnosis of a child with autism has short- and long-term impacts on family functioning. With early diagnosis, the diagnostic process is likely to co-occur with family planning decisions, yet little is known about how parents navigate this process. This study explores family planning decision making process among mothers of young children with autism spectrum disorder in the United States, by understanding the transformation in family vision before and after the diagnosis. A total of 22 mothers of first born children, diagnosed with autism between 2 and 4 years of age, were interviewed about family vision prior to and after their child's diagnosis. Grounded Theory method was used for data analysis. Findings indicated that coherence of early family vision, maternal cognitive flexibility, and maternal responses to diagnosis were highly influential in future family planning decisions. The decision to have additional children reflected a high level of adaptability built upon a solid internalized family model and a flexible approach to life. Decision to stop childrearing reflected a relatively less coherent family model and more rigid cognitive style followed by ongoing hardship managing life after the diagnosis. This report may be useful for health-care providers in enhancing therapeutic alliance and guiding family planning counseling. © The Author(s) 2015.

  10. The prevalence of self-reported vision difficulty in economically disadvantaged regions of South Africa

    PubMed Central

    Naidoo, Kovin S.; Ramson, Prasidh; Chinanayi, Farai; Zhuwau, Tom; Øverland, Lene

    2015-01-01

    Background Vision impairment, resulting in vision difficulties, is a leading cause of disability, and hence one of the key barriers for people to access education and employment, which may force them into poverty. Objectives The objective of this study was to determine the prevalence of self-reported vision difficulties as an indicator of vision impairment in economically disadvantaged regions in South Africa, and to examine the relationship between self-reported vision difficulties and socio-economic markers of poverty, namely, income, education and health service needs. Methods A cross-sectional study was conducted in economically disadvantaged districts to collect data from households on poverty and health, including vision difficulty. As visual acuity measurements were not conducted, the researchers used the term vision difficulty as an indicator of vision impairment. Data were collected from 27 districts (74 901 respondents). Logistic regression analysis and chi-square tests were used to determine bivariate relationships between variables and self-reported vision difficulty. Kernel density estimators were used for age, categorised by self-reported and not reported vision difficulty. Results Prevalence of self-reported vision difficulty was 11.2% (95% CI, 8.7% – 13.7%). More women (12.7%) compared to men (9.5%) self-reported vision difficulty (p < 0.01). Self-reported vision difficulty was higher (14.2%) for respondents that do not spend any money. A statistically significant relationship was found between the highest level of education and self-reporting of vision difficulty; as completed highest level of education increased, self-reporting of vision difficulty became lower (p < 0.01). A significantly higher prevalence of self-reported vision difficulty was found in respondents who are employed (p < 0.01), 17% (95% CI: 12.8% – 21.1%). Conclusion The evidence from this study suggests associations between socio-economic factors and vision difficulties that have a two-fold relationship (some factors such as education, and access to eye health services are associated with vision difficulty whilst vision difficulty may trap people in their current poverty or deepen their poverty status). The results are thus indicative of the need for further research in South Africa. PMID:28730022

  11. The Rationale for the Middle Level School. Practitioner's Monograph No. 9.

    ERIC Educational Resources Information Center

    Lake, Sara

    Almost from the beginning, the junior high school was based on the same vision driving today's middle level schooling: the creation of a unique middle tier of education that bridges the gap between elementary and secondary education and focuses on meeting early adolescent students' academic and personal needs. In the 1950s and 1960s, middle school…

  12. Effects of multifocal soft contact lenses used to slow myopia progression on quality of vision in young adults.

    PubMed

    Kang, Pauline; McAlinden, Colm; Wildsoet, Christine F

    2017-02-01

    To assess the effects of multifocal soft contact lenses (MF SCLs) used for myopia control on visual acuity (VA) and subjective quality of vision. Twenty-four young adult myopes had baseline high and low-contrast VAs and refractions measured and quality of vision assessed by the Quality of Vision (QoV) questionnaire with single vision SCLs. Additional VA and QoV questionnaire data were collected immediately after subjects were fitted with Proclear MF SCLs and again after a 2-week adaptation period of daily lens wear. Data were collected for two MF SCL designs, incorporating +1.50 and +3.00 D peripheral near additions, with a week washout period allowed between the two lens trials. High- and low-contrast VAs were initially reduced with both MF SCL designs, but subsequently improved to be not significantly reduced in the case of high-contrast VA by the end of the 2-week adaptation period. The quality of vision was also reduced, more so with the +3.00 D MF SCL. Quality of Vision (QoV) scores describing frequency, severity and bothersome nature of visual symptoms indicated symptoms worsening rather than resolving over the 2-week period, particularly so with the +3.00 D MF SCL. Low and high add MF SCLs adversely affected vision on initial insertion, with sustained effects on low-contrast VA and QoV scores but not high-contrast VA. Thus, high-contrast VA is not a suitable surrogate for quality of vision. In prescribing MF SCLs for myopia control, clinicians should educate patients about these effects on vision. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Evaluation of visual acuity with Gen 3 night vision goggles

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur; Kaiser, Mary K.

    1994-01-01

    Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.

  14. Darwin in the Context of Cosmic Vision 2015-2025

    NASA Astrophysics Data System (ADS)

    Liseau, R.

    2010-10-01

    The present status of the Darwin mission will be briefly reviewed, with particular focus on various developments since 2007. Of special interest is the readiness level (TRL) of critical mission technologies. While Darwin has essentially been put in limbo in Europe, continued research by the TPF-I team in the USA has demonstrated the high level of maturity which has recently been achieved for the critical technologies. This should encourage us to prepare for the next Cosmic Visions call by ESA. This call is expected to be issued in 2010/2011, reasonably well-timed with the upcoming US Decadal Survey. We argue that the SIM Lite mission would be an important milestone on the road toward Darwin-TPF and that ESA should join NASA in this endeavor.

  15. 75 FR 61833 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ...FMCSA announces its decision to exempt 17 individuals from the vision requirement in the Federal Motor Carrier Safety Regulations (FMCSRs). The exemptions will enable these individuals to operate commercial motor vehicles (CMVs) in interstate commerce without meeting the prescribed vision standard. The Agency has concluded that granting these exemptions will provide a level of safety that is equivalent to, or greater than, the level of safety maintained without the exemptions for these CMV drivers.

  16. 75 FR 79081 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ...FMCSA announces its decision to exempt 16 individuals from the vision requirement in the Federal Motor Carrier Safety Regulations (FMCSRs). The exemptions will enable these individuals to operate commercial motor vehicles (CMVs) in interstate commerce without meeting the prescribed vision standard. The Agency has concluded that granting these exemptions will provide a level of safety that is equivalent to, or greater than, the level of safety maintained without the exemptions for these CMV drivers.

  17. Measuring exertion time, duty cycle and hand activity level for industrial tasks using computer vision.

    PubMed

    Akkas, Oguz; Lee, Cheng Hsien; Hu, Yu Hen; Harris Adamson, Carisa; Rempel, David; Radwin, Robert G

    2017-12-01

    Two computer vision algorithms were developed to automatically estimate exertion time, duty cycle (DC) and hand activity level (HAL) from videos of workers performing 50 industrial tasks. The average DC difference between manual frame-by-frame analysis and the computer vision DC was -5.8% for the Decision Tree (DT) algorithm, and 1.4% for the Feature Vector Training (FVT) algorithm. The average HAL difference was 0.5 for the DT algorithm and 0.3 for the FVT algorithm. A sensitivity analysis, conducted to examine the influence that deviations in DC have on HAL, found it remained unaffected when DC error was less than 5%. Thus, a DC error less than 10% will impact HAL less than 0.5 HAL, which is negligible. Automatic computer vision HAL estimates were therefore comparable to manual frame-by-frame estimates. Practitioner Summary: Computer vision was used to automatically estimate exertion time, duty cycle and hand activity level from videos of workers performing industrial tasks.

  18. Vision preference in dynamic posturography analysed according to vestibular impairment and handicap.

    PubMed

    Perez, N I; Rama, J I; Martinez Vila, E

    2004-01-01

    The objective of this work was to characterise the implications of vision preference derived from the sensory organisation test of computerised dynamic posturography, in terms of impairment, disability and handicap. This was a prospective assessment of 88 patients suffering from dizziness who denied experiencing any visually induced vertiginous symptoms. The level of impairment of each patient was estimated by performing a complete analysis of vestibular function by means of the caloric and rotatory stimulation tests. Disability and handicap were determined with the Dizziness Handicap Inventory questionnaire (DHI). The results of the caloric test in patients were independent of vision preference although canal paresis was more frequently abnormal in patients without visual preference. No differences were found in the results of rotatory stimulation by means of impulse and sinusoidal tests, both at high velocities of stimuli, in between patients with and without vision preference. Similarly, the responses in the DHI, a common questionnaire for vestibular disability and handicap and, specifically to questions addressing the problem of visual and vestibular disability, were not able to differentiate either group of patients. Nevertheless, we have found that patients with vision preference tend to have poorer balance. We consider that in the patients studied here, vision preference must be considered as a normal finding as this represents a normal strategy in a subject that relies more heavily on visual cues for his or her postural control.

  19. Flight Testing an Integrated Synthetic Vision System

    NASA Technical Reports Server (NTRS)

    Kramer, Lynda J.; Arthur, Jarvis J., III; Bailey, Randall E.; Prinzel, Lawrence J., III

    2005-01-01

    NASA's Synthetic Vision Systems (SVS) project is developing technologies with practical applications to eliminate low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced pathway guidance for transport aircraft. The SVS concept being developed at NASA encompasses the integration of tactical and strategic Synthetic Vision Display Concepts (SVDC) with Runway Incursion Prevention System (RIPS) alerting and display concepts, real-time terrain database integrity monitoring equipment (DIME), and Enhanced Vision Systems (EVS) and/or improved Weather Radar for real-time object detection and database integrity monitoring. A flight test evaluation was jointly conducted (in July and August 2004) by NASA Langley Research Center and an industry partner team under NASA's Aviation Safety and Security, Synthetic Vision System project. A Gulfstream GV aircraft was flown over a 3-week period in the Reno/Tahoe International Airport (NV) local area and an additional 3-week period in the Wallops Flight Facility (VA) local area to evaluate integrated Synthetic Vision System concepts. The enabling technologies (RIPS, EVS and DIME) were integrated into the larger SVS concept design. This paper presents experimental methods and the high level results of this flight test.

  20. Perceived overprotection, instrumental support and rehabilitation use in elders with vision loss: a longitudinal perspective.

    PubMed

    Cimarolli, Verena R; Boerner, Kathrin; Reinhardt, Joann P; Horowitz, Amy

    2013-01-01

    This study's purpose was to investigate changes in perceived overprotection - a problematic aspect of close relationships - over time in relationship to instrumental support receipt and vision rehabilitation service use in a sample of older adults with vision impairment. Participants were 584 older adults with chronic vision impairment who were interviewed three times over a 12-month period. Longitudinal data were analysed using a latent growth curve methodology to examine change over time in perceived overprotection and instrumental support in relation to vision rehabilitation service use. Self-reported levels of overprotection and receipt of instrumental support. Results. Over time perceived overprotection increased but not instrumental support. While perceived overprotection was positively associated with instrumental support initially, over time this relationship did not emerge. Perceived overprotection and instrumental support functioned as predictors of vision rehabilitation hours. However, over time vision rehabilitation service use did not influence these social supports. Perceived overprotection increases over time, yet this change is unaffected by rehabilitation service use and instrumental support. Both family members and elders need to be involved in the vision rehabilitation process and educated about how some level of independence can be regained.

  1. Ecosystem objectives to support the UK vision for the marine environment.

    PubMed

    Rogers, S I; Tasker, M L; Earll, R; Gubbay, S

    2007-02-01

    European Maritime States already have commitments to protect species and habitats and maintain quality standards in coastal and offshore waters. These are a direct response to environmental legislation in Europe and commitments made to biodiversity conservation in OSPAR and at the World Summit on Sustainable Development. An integrated approach to management requires that these are consistent with the requirements for sustainable development, and include wider social considerations and active stakeholder participation. This review describes a hierarchical framework that incorporates the marine objectives and delivery statements of ecological, social and economic sectors. The framework leads from the UK's guiding principles for sustainable development, through visionary statements and strategic goals for high level delivery, to operational objectives and statements of action which deliver management. Parts of this hierarchy can already be populated for the UK, especially those at the higher levels. At the operational level, however, there is less clarity. The review shows that, despite some gaps, existing commitments for ecological components of the ecosystem are transparent and generally conform to this framework, due largely to high profile government funding of environmental protection and science and a single national vision for the marine environment. Specific objectives for six components of the ecosystem were developed; benthic habitats, seabirds and mammals, phytoplankton and zooplankton, fish, and physical/chemical quality of the water and atmosphere. The objectives included some that avoided limits and others that aimed to achieve targets, and for management to be effective it will be important to have a common understanding of how these can together be interpreted and made operational. In a review of 13 social and economic sectors, few provided a clear breakdown of objectives leading from a high level vision or a sustainable development principle. Six sectors did not have high level government targets for production or other measures of sectoral performance. Such commercial operations generally determine their own operational delivery targets based on market forces. Recent proposals in Europe to create an integrated framework for social, economic and environmental activities will need to carefully balance the development of a strong and competitive marine economy with existing international obligations to environmental protection.

  2. Uranus: a rapid prototyping tool for FPGA embedded computer vision

    NASA Astrophysics Data System (ADS)

    Rosales-Hernández, Victor; Castillo-Jimenez, Liz; Viveros-Velez, Gilberto; Zuñiga-Grajeda, Virgilio; Treviño Torres, Abel; Arias-Estrada, M.

    2007-01-01

    The starting point for all successful system development is the simulation. Performing high level simulation of a system can help to identify, insolate and fix design problems. This work presents Uranus, a software tool for simulation and evaluation of image processing algorithms with support to migrate them to an FPGA environment for algorithm acceleration and embedded processes purposes. The tool includes an integrated library of previous coded operators in software and provides the necessary support to read and display image sequences as well as video files. The user can use the previous compiled soft-operators in a high level process chain, and code his own operators. Additional to the prototyping tool, Uranus offers FPGA-based hardware architecture with the same organization as the software prototyping part. The hardware architecture contains a library of FPGA IP cores for image processing that are connected with a PowerPC based system. The Uranus environment is intended for rapid prototyping of machine vision and the migration to FPGA accelerator platform, and it is distributed for academic purposes.

  3. The effects of moon illumination, moon angle, cloud cover, and sky glow on night vision goggle flight performance

    NASA Astrophysics Data System (ADS)

    Loro, Stephen Lee

    This study was designed to examine moon illumination, moon angle, cloud cover, sky glow, and Night Vision Goggle (NVG) flight performance to determine possible effects. The research was a causal-comparative design. The sample consisted of 194 Fort Rucker Initial Entry Rotary Wing NVG flight students being observed by 69 NVG Instructor Pilots. The students participated in NVG flight training from September 1992 through January 1993. Data were collected using a questionnaire. Observations were analyzed using a Kruskal-Wallis one-way analysis of variance and a Wilcox matched pairs signed-ranks test for difference. Correlations were analyzed using Pearson's r. The analyses results indicated that performance at high moon illumination levels is superior to zero moon illumination, and in most task maneuvers, superior to >0%--50% moon illumination. No differences were found in performance at moon illumination levels above 50%. Moon angle had no effect on night vision goggle flight performance. Cloud cover and sky glow have selective effects on different maneuvers. For most task maneuvers, cloud cover does not affect performance. Overcast cloud cover had a significant effect on seven of the 14 task maneuvers. Sky glow did not affect eight out of 14 task maneuvers at any level of sky glow.

  4. Enhanced modeling and simulation of EO/IR sensor systems

    NASA Astrophysics Data System (ADS)

    Hixson, Jonathan G.; Miller, Brian; May, Christopher

    2015-05-01

    The testing and evaluation process developed by the Night Vision and Electronic Sensors Directorate (NVESD) Modeling and Simulation Division (MSD) provides end to end systems evaluation, testing, and training of EO/IR sensors. By combining NV-LabCap, the Night Vision Integrated Performance Model (NV-IPM), One Semi-Automated Forces (OneSAF) input sensor file generation, and the Night Vision Image Generator (NVIG) capabilities, NVESD provides confidence to the M&S community that EO/IR sensor developmental and operational testing and evaluation are accurately represented throughout the lifecycle of an EO/IR system. This new process allows for both theoretical and actual sensor testing. A sensor can be theoretically designed in NV-IPM, modeled in NV-IPM, and then seamlessly input into the wargames for operational analysis. After theoretical design, prototype sensors can be measured by using NV-LabCap, then modeled in NV-IPM and input into wargames for further evaluation. The measurement process to high fidelity modeling and simulation can then be repeated again and again throughout the entire life cycle of an EO/IR sensor as needed, to include LRIP, full rate production, and even after Depot Level Maintenance. This is a prototypical example of how an engineering level model and higher level simulations can share models to mutual benefit.

  5. Temporary effects of alcohol on color vision

    NASA Astrophysics Data System (ADS)

    Geniusz, Maciej K.; Geniusz, Malwina; Szmigiel, Marta; Przeździecka-Dołyk, Joanna

    2017-09-01

    The color vision has been described as one to be very sensitive to the intake of several chemicals. The present research reviews the published literature that is concerned with color vision impairment due to alcohol. Most of this research considers people under long-term effects of alcohol. However, there is little information about temporary effects of alcohol on color vision. A group of ten volunteers aged 18-40 was studied. During the study levels of alcohol in the body were tested with a standard breathalyzer while color vision were studied using Farnsworth Munsell 100 Hue Color Vision Tests. Keywords: Col

  6. High-fidelity, low-cost, automated method to assess laparoscopic skills objectively.

    PubMed

    Gray, Richard J; Kahol, Kanav; Islam, Gazi; Smith, Marshall; Chapital, Alyssa; Ferrara, John

    2012-01-01

    We sought to define the extent to which a motion analysis-based assessment system constructed with simple equipment could measure technical skill objectively and quantitatively. An "off-the-shelf" digital video system was used to capture the hand and instrument movement of surgical trainees (beginner level = PGY-1, intermediate level = PGY-3, and advanced level = PGY-5/fellows) while they performed a peg transfer exercise. The video data were passed through a custom computer vision algorithm that analyzed incoming pixels to measure movement smoothness objectively. The beginner-level group had the poorest performance, whereas those in the advanced group generated the highest scores. Intermediate-level trainees scored significantly (p < 0.04) better than beginner trainees. Advanced-level trainees scored significantly better than intermediate-level trainees and beginner-level trainees (p < 0.04 and p < 0.03, respectively). A computer vision-based analysis of surgical movements provides an objective basis for technical expertise-level analysis with construct validity. The technology to capture the data is simple, low cost, and readily available, and it obviates the need for expert human assessment in this setting. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  7. Development of embedded real-time and high-speed vision platform

    NASA Astrophysics Data System (ADS)

    Ouyang, Zhenxing; Dong, Yimin; Yang, Hua

    2015-12-01

    Currently, high-speed vision platforms are widely used in many applications, such as robotics and automation industry. However, a personal computer (PC) whose over-large size is not suitable and applicable in compact systems is an indispensable component for human-computer interaction in traditional high-speed vision platforms. Therefore, this paper develops an embedded real-time and high-speed vision platform, ER-HVP Vision which is able to work completely out of PC. In this new platform, an embedded CPU-based board is designed as substitution for PC and a DSP and FPGA board is developed for implementing image parallel algorithms in FPGA and image sequential algorithms in DSP. Hence, the capability of ER-HVP Vision with size of 320mm x 250mm x 87mm can be presented in more compact condition. Experimental results are also given to indicate that the real-time detection and counting of the moving target at a frame rate of 200 fps at 512 x 512 pixels under the operation of this newly developed vision platform are feasible.

  8. The Employment Effects of High-Technology: A Case Study of Machine Vision. Research Report No. 86-19.

    ERIC Educational Resources Information Center

    Chen, Kan; Stafford, Frank P.

    A case study of machine vision was conducted to identify and analyze the employment effects of high technology in general. (Machine vision is the automatic acquisition and analysis of an image to obtain desired information for use in controlling an industrial activity, such as the visual sensor system that gives eyes to a robot.) Machine vision as…

  9. Salient contour extraction from complex natural scene in night vision image

    NASA Astrophysics Data System (ADS)

    Han, Jing; Yue, Jiang; Zhang, Yi; Bai, Lian-fa

    2014-03-01

    The theory of center-surround interaction in non-classical receptive field can be applied in night vision information processing. In this work, an optimized compound receptive field modulation method is proposed to extract salient contour from complex natural scene in low-light-level (LLL) and infrared images. The kernel idea is that multi-feature analysis can recognize the inhomogeneity in modulatory coverage more accurately and that center and surround with the grouping structure satisfying Gestalt rule deserves high connection-probability. Computationally, a multi-feature contrast weighted inhibition model is presented to suppress background and lower mutual inhibition among contour elements; a fuzzy connection facilitation model is proposed to achieve the enhancement of contour response, the connection of discontinuous contour and the further elimination of randomly distributed noise and texture; a multi-scale iterative attention method is designed to accomplish dynamic modulation process and extract contours of targets in multi-size. This work provides a series of biologically motivated computational visual models with high-performance for contour detection from cluttered scene in night vision images.

  10. Physical and sporting activities improve vestibular afferent usage and balance in elderly human subjects.

    PubMed

    Gauchard, G C; Jeandel, C; Perrin, P P

    2001-01-01

    Ageing is associated with a reduction in balance, in particular through dysfunction of each level of postural control, which results in an increased risk of falling. Conversely, the practice of physical activities has been shown to modulate postural control in elderly people. This study examined the potential positive effects of two types of regular physical and sporting activities on vestibular information and their relation to posture. Gaze and postural stabilisation was evaluated by caloric and rotational vestibular tests on 18 healthy subjects over the age of 60 who regularly practised low-energy or bioenergetic physical activities and on 18 controls of a similar age who only walked on a regular basis. These subjects were also submitted to static and dynamic posturographic tests. The control group displayed less balance control, with a lower vestibular sensitivity and a relatively high dependency on vision compared to the group practising low-energy physical activities, which had better postural control with good vestibular sensitivity and less dependency on vision. The postural control and vestibular sensitivity of subjects practising bioenergetic activities was average, and required higher visual afferent contribution. Low-energy exercises, already shown to have the most positive impact on balance control by relying more on proprioception, also appear to develop or maintain a high level of vestibular sensitivity allowing elderly people practising such exercises to reduce the weight of vision. Copyright 2001 S. Karger AG, Basel

  11. Mathematics Teacher Professional Development as a Virtual Boundary Encounter

    ERIC Educational Resources Information Center

    Matranga, Anthony Vincent

    2017-01-01

    Mathematics instruction in US schools is largely inconsistent with visions of research and policy, which suggest instruction should be student-centered, maintain high levels of cognitive demand, and support rich mathematical discussion and argumentation. Professional development (PD) figures prominently in addressing this issue, and studies have…

  12. Understanding and Coping with "Leadership Blues"

    ERIC Educational Resources Information Center

    Foster, Lenoar

    2006-01-01

    Three counterbalancing realities confront the contemporary school principal and each one has the capacity to produce psychic highs and lows in the conduct and vision of principals as they lead schools to higher levels of instructional improvement and community engagement. First, contemporary principals are expected to provide an organizational…

  13. Design and Performance of a 1 ms High-Speed Vision Chip with 3D-Stacked 140 GOPS Column-Parallel PEs †.

    PubMed

    Nose, Atsushi; Yamazaki, Tomohiro; Katayama, Hironobu; Uehara, Shuji; Kobayashi, Masatsugu; Shida, Sayaka; Odahara, Masaki; Takamiya, Kenichi; Matsumoto, Shizunori; Miyashita, Leo; Watanabe, Yoshihiro; Izawa, Takashi; Muramatsu, Yoshinori; Nitta, Yoshikazu; Ishikawa, Masatoshi

    2018-04-24

    We have developed a high-speed vision chip using 3D stacking technology to address the increasing demand for high-speed vision chips in diverse applications. The chip comprises a 1/3.2-inch, 1.27 Mpixel, 500 fps (0.31 Mpixel, 1000 fps, 2 × 2 binning) vision chip with 3D-stacked column-parallel Analog-to-Digital Converters (ADCs) and 140 Giga Operation per Second (GOPS) programmable Single Instruction Multiple Data (SIMD) column-parallel PEs for new sensing applications. The 3D-stacked structure and column parallel processing architecture achieve high sensitivity, high resolution, and high-accuracy object positioning.

  14. The manipulation of vision during the powerlift squat: exploring the boundaries of the specificity of learning hypothesis.

    PubMed

    Bennett, S; Davids, K

    1995-09-01

    The available information for controlling a multidegree-of-freedom sport action was manipulated in 2 experiments. In the first, 10 intermediate lifters were participants; for the second, 8 skilled and 8 less skilled lifters were observed. Three single repetitions of a powerlift squat were performed under 3 vision conditions (i.e., full, ambient, no vision). The less skilled and intermediate lifters' technical performance decreased significantly with the removal of visual information. There was no detrimental effect in the skilled group. Despite the differing information constraints, skilled lifters exhibited a high level of positioning accuracy and timing consistency across conditions. These data fail to support the theoretical predictions of the specificity of learning hypothesis. The differences between the task constraints in this study and those in manual aiming investigations may represent a boundary to the current propositions of the specificity of learning hypothesis.

  15. Application of the Modular Automated Reconfigurable Assembly System (MARAS) concept to adaptable vision gauging and parts feeding

    NASA Technical Reports Server (NTRS)

    By, Andre Bernard; Caron, Ken; Rothenberg, Michael; Sales, Vic

    1994-01-01

    This paper presents the first phase results of a collaborative effort between university researchers and a flexible assembly systems integrator to implement a comprehensive modular approach to flexible assembly automation. This approach, named MARAS (Modular Automated Reconfigurable Assembly System), has been structured to support multiple levels of modularity in terms of both physical components and system control functions. The initial focus of the MARAS development has been on parts gauging and feeding operations for cylinder lock assembly. This phase is nearing completion and has resulted in the development of a highly configurable system for vision gauging functions on a wide range of small components (2 mm to 100 mm in size). The reconfigurable concepts implemented in this adaptive Vision Gauging Module (VGM) are now being extended to applicable aspects of the singulating, selecting, and orienting functions required for the flexible feeding of similar mechanical components and assemblies.

  16. The role of 11-cis-retinyl esters in vertebrate cone vision.

    PubMed

    Babino, Darwin; Perkins, Brian D; Kindermann, Aljoscha; Oberhauser, Vitus; von Lintig, Johannes

    2015-01-01

    A cycle of cis-to-trans isomerization of the chromophore is intrinsic to vertebrate vision where rod and cone photoreceptors mediate dim- and bright-light vision, respectively. Daylight illumination can greatly exceed the rate at which the photoproduct can be recycled back to the chromophore by the canonical visual cycle. Thus, an additional supply pathway(s) must exist to sustain cone-dependent vision. Two-photon microscopy revealed that the eyes of the zebrafish (Danio rerio) contain high levels of 11-cis-retinyl esters (11-REs) within the retinal pigment epithelium. HPLC analyses demonstrate that 11-REs are bleached by bright light and regenerated in the dark. Pharmacologic treatment with all-trans-retinylamine (Ret-NH2), a potent and specific inhibitor of the trans-to-cis reisomerization reaction of the canonical visual cycle, impeded the regeneration of 11-REs. Intervention with 11-cis-retinol restored the regeneration of 11-REs in the presence of all-trans-Ret-NH2. We used the XOPS:mCFP transgenic zebrafish line with a functional cone-only retina to directly demonstrate that this 11-RE cycle is critical to maintain vision under bright-light conditions. Thus, our analyses reveal that a dark-generated pool of 11-REs helps to supply photoreceptors with the chromophore under the varying light conditions present in natural environments. © FASEB.

  17. Association Between County-Level Characteristics and Eye Care Use by US Adults in 22 States After Accounting for Individual-Level Characteristics Using a Conceptual Framework.

    PubMed

    Chou, Chiu-Fang; Beckles, Gloria L; Cheng, Yiling J; Saaddine, Jinan B

    2016-10-01

    Individual-level characteristics are associated with eye care use. The influence of contextual factors on vision and eye health, as well as health behavior, is unknown. To examine the association between county-level characteristics and eye care use after accounting for individual-level characteristics using a conceptual framework. This investigation was a cross-sectional study of respondents 40 years and older participating in the Behavioral Risk Factor Surveillance System surveys between 2006 and 2010 from 22 states that used the Visual Impairment and Access to Eye Care module. Multilevel regressions were used to examine the association between county-level characteristics and eye care use after adjusting for individual-level characteristics (age, sex, race/ethnicity, educational attainment, annual household income, employment status, health care insurance coverage, eye care insurance coverage, personal established physician, poor vision or eye health, and diabetes status). Data analysis was performed from March 23, 2014, to June 7, 2016. Eye care visit and receipt of a dilated eye examination in the past year. Among 117 295 respondents who resided in 828 counties, individual-level data were obtained from the Behavioral Risk Factor Surveillance System surveys. All county-level variables were aggregated at the county level from the Behavioral Risk Factor Surveillance System surveys except for a high geographic density of eye care professionals, which was obtained from the 2010 Area Health Resource File. After controlling for individual-level characteristics, the odds of reporting an eye care visit in the past year were significantly higher among people living in counties with high percentages of black individuals (adjusted odds ratio [aOR], 1.12; 95% CI, 1.01-1.24; P = .04) or low-income households (aOR, 1.12; 95% CI, 1.00-1.25; P = .045) or with a high density of eye care professionals (aOR, 1.18; 95% CI, 1.07-1.29; P < .001) than among those living in counties with the lowest tertile of each county-level characteristic. The odds of reporting receipt of a dilated eye examination in the past year were also higher among people living in counties with the highest percentages of black individuals (aOR, 1.20; 95% CI, 1.07-1.34; P = .002) or low-income households (aOR, 1.17; 95% CI, 1.04-1.32; P = .01). However, the odds of reported receipt of a dilated eye examination in the past year were lower in counties with the highest percentages of people with poor vision and eye health compared with counties with lower percentages (aOR, 0.85; 95% CI, 0.77-0.94; P = .002). Contextual factors, measured at the county level, were associated with eye care use independent of individual-level characteristics. The findings suggest that, while individual characteristics influence health care use, it is also important to address contextual factors to improve eye care use and ultimately vision health.

  18. The Impact of Change in Visual Field on Health-Related Quality of Life: The Los Angeles Latino Eye Study

    PubMed Central

    Patino, Cecilia M.; Varma, Rohit; Azen, Stanley P.; Conti, David V.; Nichol, Michael B.; McKean-Cowdin, Roberta

    2010-01-01

    Purpose To assess the impact of change in visual field (VF) on change in health related quality of life (HRQoL) at the population level. Design Prospective cohort study Participants 3,175 Los Angles Latino Eye Study (LALES) participants Methods Objective measures of VF and visual acuity and self-reported HRQoL were collected at baseline and 4-year follow-up. Analysis of covariance was used to evaluate mean differences in change of HRQoL across severity levels of change in VF and to test for effect modification by covariates. Main outcome measures General and vision-specific HRQoL. Results Of 3,175 participants, 1430 (46%) showed a change in VF (≥1 decibel [dB]) and 1651, 1715 (54%) reported a clinically important change (≥5 points) in vision-specific HRQoL. Progressive worsening and improvement in the VF were associated with increasing losses and gains in vision-specific HRQoL for the composite score and 10 of its 11 subscales (all Ptrends<0.05). Losses in VF > 5 dB and gains > 3 dB were associated with clinically meaningful losses and gains in vision-specific HRQoL, respectively. Areas of vision-specific HRQoL most affected by greater losses in VF were driving, dependency, role-functioning, and mental health. The effect of change in VF (loss or gain) on mean change in vision-specific HRQoL varied by level of baseline vision loss (in visual field and/or visual acuity) and by change in visual acuity (all P-interactions<0.05). Those with moderate/severe VF loss at baseline and with a > 5 dB loss in visual field during the study period had a mean loss of vision-specific HRQoL of 11.3 points, while those with no VF loss at baseline had a mean loss of 0.97 points Similarly, with a > 5 dB loss in VF and baseline visual acuity impairment (mild/severe) there was a loss in vision-specific HRQoL of 10.5 points, whereas with no visual acuity impairment at baseline there was a loss of vision-specific HRQoL of 3.7 points. Conclusion Both losses and gains in VF produce clinically meaningful changes in vision-specific HRQoL. In the presence of pre-existing vision loss (VF and visual acuity), similar levels of visual field change produce greater losses in quality of life. PMID:21458074

  19. Impact of Gamification of Vision Tests on the User Experience.

    PubMed

    Bodduluri, Lakshmi; Boon, Mei Ying; Ryan, Malcolm; Dain, Stephen J

    2017-08-01

    Gamification has been incorporated into vision tests and vision therapies in the expectation that it may increase the user experience and engagement with the task. The current study aimed to understand how gamification affects the user experience, specifically during the undertaking of psychophysical tasks designed to estimate vision thresholds (chromatic and achromatic contrast sensitivity). Three tablet computer-based games were developed with three levels of gaming elements. Game 1 was designed to be a simple clinical test (no gaming elements), game 2 was similar to game 1 but with added gaming elements (i.e., feedback, scores, and sounds), and game 3 was a complete game. Participants (N = 144, age: 9.9-42 years) played three games in random order. The user experience for each game was assessed using a Short Feedback Questionnaire. The median (interquartile range) fun level for the three games was 2.5 (1.6), 3.9 (1.7), and 2.5 (2.8), respectively. Overall, participants reported greater fun level and higher preparedness to play the game again for game 2 than games 1 and 3 (P < 0.05). There were significant positive correlations observed between fun level and preparedness to play the game again for all the games (p < 0.05). Engagement (assessed as completion rates) did not differ between the games. Gamified version (game 2) was preferred to the other two versions. Over the short term, the careful application of gaming elements to vision tests was found to increase the fun level of users, without affecting engagement with the vision test.

  20. Active vision and image/video understanding with decision structures based on the network-symbolic models

    NASA Astrophysics Data System (ADS)

    Kuvich, Gary

    2003-08-01

    Vision is a part of a larger information system that converts visual information into knowledge structures. These structures drive vision process, resolve ambiguity and uncertainty via feedback projections, and provide image understanding that is an interpretation of visual information in terms of such knowledge models. The ability of human brain to emulate knowledge structures in the form of networks-symbolic models is found. And that means an important shift of paradigm in our knowledge about brain from neural networks to "cortical software". Symbols, predicates and grammars naturally emerge in such active multilevel hierarchical networks, and logic is simply a way of restructuring such models. Brain analyzes an image as a graph-type decision structure created via multilevel hierarchical compression of visual information. Mid-level vision processes like clustering, perceptual grouping, separation of figure from ground, are special kinds of graph/network transformations. They convert low-level image structure into the set of more abstract ones, which represent objects and visual scene, making them easy for analysis by higher-level knowledge structures. Higher-level vision phenomena are results of such analysis. Composition of network-symbolic models works similar to frames and agents, combines learning, classification, analogy together with higher-level model-based reasoning into a single framework. Such models do not require supercomputers. Based on such principles, and using methods of Computational intelligence, an Image Understanding system can convert images into the network-symbolic knowledge models, and effectively resolve uncertainty and ambiguity, providing unifying representation for perception and cognition. That allows creating new intelligent computer vision systems for robotic and defense industries.

  1. Envisioning a career in science, technology, engineering and mathematics: some challenges and possibilities

    NASA Astrophysics Data System (ADS)

    Sharkawy, Azza

    2015-09-01

    In How High School Students Envision Their STEM Career Pathways, Lin Zhang and Michael Barnett attempt to shed light on the problem of underrepresented students (e.g., Aboriginals, Hispanics, African Americans, urban, females) in STEM higher education and related careers by exploring, in general terms, five high school students' career visions and the experiences that influenced their career visions. In this paper, I attempt to extend the authors' discussions on the underrepresentation of minority students in STEM higher education by highlighting some of the factors that begin to influence youths' career decisions long before they reach the high school level and are required to make specific career choices. I also draw on Glen Aikenhead's Sci Edu, 27, 1-52 (1996) notion of border crossing and research by Victoria Costa Sci Edu, 79, 313-333 (on the significance of the relationship between students' cultural worlds and the cultural world of school science.

  2. Helicopter flights with night-vision goggles: Human factors aspects

    NASA Technical Reports Server (NTRS)

    Brickner, Michael S.

    1989-01-01

    Night-vision goggles (NVGs) and, in particular, the advanced, helmet-mounted Aviators Night-Vision-Imaging System (ANVIS) allows helicopter pilots to perform low-level flight at night. It consists of light intensifier tubes which amplify low-intensity ambient illumination (star and moon light) and an optical system which together produce a bright image of the scene. However, these NVGs do not turn night into day, and, while they may often provide significant advantages over unaided night flight, they may also result in visual fatigue, high workload, and safety hazards. These problems reflect both system limitations and human-factors issues. A brief description of the technical characteristics of NVGs and of human night-vision capabilities is followed by a description and analysis of specific perceptual problems which occur with the use of NVGs in flight. Some of the issues addressed include: limitations imposed by a restricted field of view; problems related to binocular rivalry; the consequences of inappropriate focusing of the eye; the effects of ambient illumination levels and of various types of terrain on image quality; difficulties in distance and slope estimation; effects of dazzling; and visual fatigue and superimposed symbology. These issues are described and analyzed in terms of their possible consequences on helicopter pilot performance. The additional influence of individual differences among pilots is emphasized. Thermal imaging systems (forward looking infrared (FLIR)) are described briefly and compared to light intensifier systems (NVGs). Many of the phenomena which are described are not readily understood. More research is required to better understand the human-factors problems created by the use of NVGs and other night-vision aids, to enhance system design, and to improve training methods and simulation techniques.

  3. Visual function of police officers who have undergone refractive surgery.

    PubMed

    Hovis, Jeffery K; Ramaswamy, Shankaran

    2006-11-01

    The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.

  4. 75 FR 25843 - Notice of Public Review and Comment Period on NOAA's Arctic Vision and Strategy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-10

    ..., enhances, or leverages partnerships with other Arctic nations, international organizations, government agencies, and non-governmental organizations, academia, and local communities. The goals are also geared... those of our national and international partners, is needed. This document provides a high-level...

  5. The Impact of Visual Impairment on Perceived School Climate

    ERIC Educational Resources Information Center

    Schade, Benjamin; Larwin, Karen H.

    2015-01-01

    The current investigation examines whether visual impairment has an impact on a student's perception of the school climate. Using a large national sample of high school students, perceptions were examined for students with vision impairment relative to students with no visual impairments. Three factors were examined: self-reported level of…

  6. Panoramic Night Vision Goggle Testing For Diagnosis and Repair

    DTIC Science & Technology

    2000-01-01

    Visual Acuity Visual Acuity [ Marasco & Task, 1999] measures how well a human observer can see high contrast targets at specified light levels through...grid through the PNVG in-board and out-board channels simultaneously and comparing the defects to the size of grid features ( Marasco & Task, 1999). The

  7. Development of Air Force aerial spray night operations: High altitude swath characterization

    USDA-ARS?s Scientific Manuscript database

    Multiple trials were conducted from 2006 to 2014 in an attempt to validate aerial spray efficacy at altitudes conducive to night spray operations using night vision goggles (NVG). Higher altitude application of pesticide (>400 feet above ground level [AGL]) suggested that effective vector control mi...

  8. Comparison of low-light nonmydriatic digital imaging with 35-mm ETDRS seven-standard field stereo color fundus photographs and clinical examination.

    PubMed

    Silva, Paolo S; Walia, Saloni; Cavallerano, Jerry D; Sun, Jennifer K; Dunn, Cheri; Bursell, Sven-Erik; Aiello, Lloyd M; Aiello, Lloyd Paul

    2012-09-01

    To compare agreement between diagnosis of clinical level of diabetic retinopathy (DR) and diabetic macular edema (DME) derived from nonmydriatic fundus images using a digital camera back optimized for low-flash image capture (MegaVision) compared with standard seven-field Early Treatment Diabetic Retinopathy Study (ETDRS) photographs and dilated clinical examination. Subject comfort and image acquisition time were also evaluated. In total, 126 eyes from 67 subjects with diabetes underwent Joslin Vision Network nonmydriatic retinal imaging. ETDRS photographs were obtained after pupillary dilation, and fundus examination was performed by a retina specialist. There was near-perfect agreement between MegaVision and ETDRS photographs (κ=0.81, 95% confidence interval [CI] 0.73-0.89) for clinical DR severity levels. Substantial agreement was observed with clinical examination (κ=0.71, 95% CI 0.62-0.80). For DME severity level there was near-perfect agreement with ETDRS photographs (κ=0.92, 95% CI 0.87-0.98) and moderate agreement with clinical examination (κ=0.58, 95% CI 0.46-0.71). The wider MegaVision 45° field led to identification of nonproliferative changes in areas not imaged by the 30° field of ETDRS photos. Field area unique to ETDRS photographs identified proliferative changes not visualized with MegaVision. Mean MegaVision acquisition time was 9:52 min. After imaging, 60% of subjects preferred the MegaVision lower flash settings. When evaluated using a rigorous protocol, images captured using a low-light digital camera compared favorably with ETDRS photography and clinical examination for grading level of DR and DME. Furthermore, these data suggest the importance of more extensive peripheral images and suggest that utilization of wide-field retinal imaging may further improve accuracy of DR assessment.

  9. Ultraviolet vision may be widespread in bats

    USGS Publications Warehouse

    Gorresen, P. Marcos; Cryan, Paul; Dalton, David C.; Wolf, Sandy; Bonaccorso, Frank

    2015-01-01

    Insectivorous bats are well known for their abilities to find and pursue flying insect prey at close range using echolocation, but they also rely heavily on vision. For example, at night bats use vision to orient across landscapes, avoid large obstacles, and locate roosts. Although lacking sharp visual acuity, the eyes of bats evolved to function at very low levels of illumination. Recent evidence based on genetics, immunohistochemistry, and laboratory behavioral trials indicated that many bats can see ultraviolet light (UV), at least at illumination levels similar to or brighter than those before twilight. Despite this growing evidence for potentially widespread UV vision in bats, the prevalence of UV vision among bats remains unknown and has not been studied outside of the laboratory. We used a Y-maze to test whether wild-caught bats could see reflected UV light and whether such UV vision functions at the dim lighting conditions typically experienced by night-flying bats. Seven insectivorous species of bats, representing five genera and three families, showed a statistically significant ‘escape-toward-the-light’ behavior when placed in the Y-maze. Our results provide compelling evidence of widespread dim-light UV vision in bats.

  10. Eyes for Learning: Preventing and Curing Vision-Related Learning Problems

    ERIC Educational Resources Information Center

    Orfield, Antonia

    2007-01-01

    Dr. Orfield's highly readable guide on vision development presents ground-breaking solutions to common learning problems and is supported by substantial data. This holistic common sense--that most people do not know--is not just about vision but also how vision is interrelated with learning. It teaches how to care for a child's vision as well as…

  11. Machine vision for digital microfluidics

    NASA Astrophysics Data System (ADS)

    Shin, Yong-Jun; Lee, Jeong-Bong

    2010-01-01

    Machine vision is widely used in an industrial environment today. It can perform various tasks, such as inspecting and controlling production processes, that may require humanlike intelligence. The importance of imaging technology for biological research or medical diagnosis is greater than ever. For example, fluorescent reporter imaging enables scientists to study the dynamics of gene networks with high spatial and temporal resolution. Such high-throughput imaging is increasingly demanding the use of machine vision for real-time analysis and control. Digital microfluidics is a relatively new technology with expectations of becoming a true lab-on-a-chip platform. Utilizing digital microfluidics, only small amounts of biological samples are required and the experimental procedures can be automatically controlled. There is a strong need for the development of a digital microfluidics system integrated with machine vision for innovative biological research today. In this paper, we show how machine vision can be applied to digital microfluidics by demonstrating two applications: machine vision-based measurement of the kinetics of biomolecular interactions and machine vision-based droplet motion control. It is expected that digital microfluidics-based machine vision system will add intelligence and automation to high-throughput biological imaging in the future.

  12. Student Progress to Graduation in New York City High Schools. Part II: Student Achievement as "Stock" and "Flow"--Reimagining Early Warning Systems for At-Risk Students

    ERIC Educational Resources Information Center

    Fairchild, Susan; Carrino, Gerard; Gunton, Brad; Soderquist, Chris; Hsiao, Andrew; Donohue, Beverly; Farrell, Timothy

    2012-01-01

    New Visions for Public Schools has leveraged student-level data to help schools identify at-risk students, designed metrics to capture student progress toward graduation, developed data tools and reports that visualize student progress at different levels of aggregation for different audiences, and implemented real-time data systems for educators.…

  13. Connectionist Models and Parallelism in High Level Vision.

    DTIC Science & Technology

    1985-01-01

    GRANT NUMBER(s) Jerome A. Feldman N00014-82-K-0193 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENt. PROJECT, TASK Computer Science...Connectionist Models 2.1 Background and Overviev % Computer science is just beginning to look seriously at parallel computation : it may turn out that...the chair. The program includes intermediate level networks that compute more complex joints and ones that compute parallelograms in the image. These

  14. United States Marine Corps Cost Reduction and the Joint Battle Command Platform

    DTIC Science & Technology

    2013-09-01

    2013) ...................... 20   Figure 4.   Hierarchical multi- level representation of the JBC-P FoS capability areas and metrics (After Han et...Technician FY Fiscal Year GAO Government Accountability Office GCE Ground Combat Element GOTS Government off the Shelf HMMWV High...widely dispersed units across the battlefield (HQMC, 2013). This control is desired to be extended down to the company level and below. The vision

  15. Residual perception of biological motion in cortical blindness.

    PubMed

    Ruffieux, Nicolas; Ramon, Meike; Lao, Junpeng; Colombo, Françoise; Stacchi, Lisa; Borruat, François-Xavier; Accolla, Ettore; Annoni, Jean-Marie; Caldara, Roberto

    2016-12-01

    From birth, the human visual system shows a remarkable sensitivity for perceiving biological motion. This visual ability relies on a distributed network of brain regions and can be preserved even after damage of high-level ventral visual areas. However, it remains unknown whether this critical biological skill can withstand the loss of vision following bilateral striate damage. To address this question, we tested the categorization of human and animal biological motion in BC, a rare case of cortical blindness after anoxia-induced bilateral striate damage. The severity of his impairment, encompassing various aspects of vision (i.e., color, shape, face, and object recognition) and causing blind-like behavior, contrasts with a residual ability to process motion. We presented BC with static or dynamic point-light displays (PLDs) of human or animal walkers. These stimuli were presented either individually, or in pairs in two alternative forced choice (2AFC) tasks. When confronted with individual PLDs, the patient was unable to categorize the stimuli, irrespective of whether they were static or dynamic. In the 2AFC task, BC exhibited appropriate eye movements towards diagnostic information, but performed at chance level with static PLDs, in stark contrast to his ability to efficiently categorize dynamic biological agents. This striking ability to categorize biological motion provided top-down information is important for at least two reasons. Firstly, it emphasizes the importance of assessing patients' (visual) abilities across a range of task constraints, which can reveal potential residual abilities that may in turn represent a key feature for patient rehabilitation. Finally, our findings reinforce the view that the neural network processing biological motion can efficiently operate despite severely impaired low-level vision, positing our natural predisposition for processing dynamicity in biological agents as a robust feature of human vision. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. [Analysis of the changes in the causes of blindness and significant vision loss among children and young adults born between 1974 and 2004].

    PubMed

    Seroczyńska, Małgorzata; Grałek, Mirosława; Kanigowska, Krystyna

    2007-01-01

    Visual impairment develops serious medical, psychological, social and economical problems. Thus, of most importance is improvement in prophylaxis, early diagnosis and treatment. THE AIM of this paper is to define the reasons of blindness and significant loss of vision in children and youths in Poland, and changes in them among children and youths under the age of 24, born between 1974-2004, with classification by age. Included in the study were the records of 2,518 children and youths under the age of 24, associates of the Polski Zwiazek Niewidomych (PZN, Polish Association of the Blind); these were analyzed for the prevalence of each cause of vision loss. There were two groups. The first group were files of 1,504 students and pupils in the institutions for blind and visually impaired children, and the archives of PZN, describing the members who joined it between year 1974 and 1998. The second, comparative group, was based on files of 1,014 children and students, who joined PZN between year 1999 and 2004. Each group was also analysed within different age groups. The most important causes of visual impairment are: optic nerve atrophy, retinopathy of prematurity (ROP), high myopia, congenital cataract and retinal degradations. Changes in them between 1998-2004 introduce a percentage growth of optic nerve atrophy from 21.66% to 25.41% and decrement in vision degrading stages of ROP from 14.14% to 10.71%, in development disorders from 8.09% to 7.10%. There is an alarming growth in congenital toxoplasmosis percentage, from 1.06% to 2.39%, and of congenital cataract, from 3.02% to 4.47%. High myopia among the visually impaired remains at the same level. There is a big growth in the percentage of heavy (bilateral) injuries, which cause significant vision loss. Less often, the cause of serious vision damage are uveitis, secondary glaucoma and toxocariasis. The study conducted between 1998-2004 revealed changes in the causes of blindness and significantly vision loss in children and youths under the age of 24, as compared to a similar study conducted between 1974-1998. There is constant increase of the optic nerve atrophy as a cause of vision loss, and decrease among vision impairments caused by vision damaging stages of ROP. Cataract and congenital abnormalities are more frequent among youngest children. Cortical blindness, formerly rarely diagnosed, is becoming a significant factor. The results of our study, describing the changes in blindness and significant vision loss factors, should provide a proper rationale for developing a strategy for control of visual impairment in children and youths.

  17. Cohort: critical science

    NASA Astrophysics Data System (ADS)

    Digney, Bruce L.

    2007-04-01

    Unmanned vehicle systems is an attractive technology for the military, but whose promises have remained largely undelivered. There currently exist fielded remote controlled UGVs and high altitude UAV whose benefits are based on standoff in low complexity environments with sufficiently low control reaction time requirements to allow for teleoperation. While effective within there limited operational niche such systems do not meet with the vision of future military UxV scenarios. Such scenarios envision unmanned vehicles operating effectively in complex environments and situations with high levels of independence and effective coordination with other machines and humans pursing high level, changing and sometimes conflicting goals. While these aims are clearly ambitious they do provide necessary targets and inspiration with hopes of fielding near term useful semi-autonomous unmanned systems. Autonomy involves many fields of research including machine vision, artificial intelligence, control theory, machine learning and distributed systems all of which are intertwined and have goals of creating more versatile broadly applicable algorithms. Cohort is a major Applied Research Program (ARP) led by Defence R&D Canada (DRDC) Suffield and its aim is to develop coordinated teams of unmanned vehicles (UxVs) for urban environments. This paper will discuss the critical science being addressed by DRDC developing semi-autonomous systems.

  18. Vision Screening of School Children by Teachers as a Community Based Strategy to Address the Challenges of Childhood Blindness.

    PubMed

    Kaur, Gurvinder; Koshy, Jacob; Thomas, Satish; Kapoor, Harpreet; Zachariah, Jiju George; Bedi, Sahiba

    2016-04-01

    Early detection and treatment of vision problems in children is imperative to meet the challenges of childhood blindness. Considering the problems of inequitable distribution of trained manpower and limited access of quality eye care services to majority of our population, innovative community based strategies like 'Teachers training in vision screening' need to be developed for effective utilization of the available human resources. To evaluate the effectiveness of introducing teachers as the first level vision screeners. Teacher training programs were conducted for school teachers to educate them about childhood ocular disorders and the importance of their early detection. Teachers from government and semi-government schools located in Ludhiana were given training in vision screening. These teachers then conducted vision screening of children in their schools. Subsequently an ophthalmology team visited these schools for re-evaluation of children identified with low vision. Refraction was performed for all children identified with refractive errors and spectacles were prescribed. Children requiring further evaluation were referred to the base hospital. The project was done in two phases. True positives, false positives, true negatives and false negatives were calculated for evaluation. In phase 1, teachers from 166 schools underwent training in vision screening. The teachers screened 30,205 children and reported eye problems in 4523 (14.97%) children. Subsequently, the ophthalmology team examined 4150 children and confirmed eye problems in 2137 children. Thus, the teachers were able to correctly identify eye problems (true positives) in 47.25% children. Also, only 13.69% children had to be examined by the ophthalmology team, thus reducing their work load. Similarly, in phase 2, 46.22% children were correctly identified to have eye problems (true positives) by the teachers. By random sampling, 95.65% children were correctly identified as normal (true negatives) by the teachers. Considering the high true negative rates and reasonably good true positive rates and the wider coverage provided by the program, vision screening in schools by teachers is an effective method of identifying children with low vision. This strategy is also valuable in reducing the workload of the eye care staff.

  19. ROC analysis of the accuracy of Noncycloplegic retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for preschool vision screening.

    PubMed

    Ying, Gui-shuang; Maguire, Maureen; Quinn, Graham; Kulp, Marjean Taylor; Cyert, Lynn

    2011-12-28

    To evaluate, by receiver operating characteristic (ROC) analysis, the accuracy of three instruments of refractive error in detecting eye conditions among 3- to 5-year-old Head Start preschoolers and to evaluate differences in accuracy between instruments and screeners and by age of the child. Children participating in the Vision In Preschoolers (VIP) Study (n = 4040), had screening tests administered by pediatric eye care providers (phase I) or by both nurse and lay screeners (phase II). Noncycloplegic retinoscopy (NCR), the Retinomax Autorefractor (Nikon, Tokyo, Japan), and the SureSight Vision Screener (SureSight, Alpharetta, GA) were used in phase I, and Retinomax and SureSight were used in phase II. Pediatric eye care providers performed a standardized eye examination to identify amblyopia, strabismus, significant refractive error, and reduced visual acuity. The accuracy of the screening tests was summarized by the area under the ROC curve (AUC) and compared between instruments and screeners and by age group. The three screening tests had a high AUC for all categories of screening personnel. The AUC for detecting any VIP-targeted condition was 0.83 for NCR, 0.83 (phase I) to 0.88 (phase II) for Retinomax, and 0.86 (phase I) to 0.87 (phase II) for SureSight. The AUC was 0.93 to 0.95 for detecting group 1 (most severe) conditions and did not differ between instruments or screeners or by age of the child. NCR, Retinomax, and SureSight had similar and high accuracy in detecting vision disorders in preschoolers across all types of screeners and age of child, consistent with previously reported results at specificity levels of 90% and 94%.

  20. Mapping the Perceptual Grain of the Human Retina

    PubMed Central

    Tuten, William S.; Roorda, Austin; Sincich, Lawrence C.

    2014-01-01

    In humans, experimental access to single sensory receptors is difficult to achieve, yet it is crucial for learning how the signals arising from each receptor are transformed into perception. By combining adaptive optics microstimulation with high-speed eye tracking, we show that retinal function can be probed at the level of the individual cone photoreceptor in living eyes. Classical psychometric functions were obtained from cone-sized microstimuli targeted to single photoreceptors. Revealed psychophysically, the cone mosaic also manifests a variable sensitivity to light across its surface that accords with a simple model of cone light capture. Because this microscopic grain of vision could be detected on the perceptual level, it suggests that photoreceptors can act individually to shape perception, if the normally suboptimal relay of light by the eye's optics is corrected. Thus the precise arrangement of cones and the exact placement of stimuli onto those cones create the initial retinal limits on signals mediating spatial vision. PMID:24741057

  1. Image enhancement filters significantly improve reading performance for low vision observers

    NASA Technical Reports Server (NTRS)

    Lawton, T. B.

    1992-01-01

    As people age, so do their photoreceptors; many photoreceptors in central vision stop functioning when a person reaches their late sixties or early seventies. Low vision observers with losses in central vision, those with age-related maculopathies, were studied. Low vision observers no longer see high spatial frequencies, being unable to resolve fine edge detail. We developed image enhancement filters to compensate for the low vision observer's losses in contrast sensitivity to intermediate and high spatial frequencies. The filters work by boosting the amplitude of the less visible intermediate spatial frequencies. The lower spatial frequencies. These image enhancement filters not only reduce the magnification needed for reading by up to 70 percent, but they also increase the observer's reading speed by 2-4 times. A summary of this research is presented.

  2. The President's Budget: New Investments, a Vision for Vulnerable Youth

    ERIC Educational Resources Information Center

    Bird, Kisha

    2014-01-01

    President Obama's Fiscal Year (FY) 2015 budget, released on March 4, reflects the Administration's commitment to helping low-income individuals and vulnerable families access pathways to economic mobility, healthy development, and high quality of life. The budget proposal adheres to spending levels established in the Bipartisan Budget…

  3. Emotional Intelligence for School Administrators: A Priority for School Reform?

    ERIC Educational Resources Information Center

    Moore, Bobby

    2009-01-01

    In order to cultivate a culture that challenges the status quo and expects excellence, school leaders need to learn, develop, and demonstrate high levels of emotional intelligence. Studying emotional intelligence provides leaders with the awareness necessary to meet the needs of a staff that is engaged in developing a common vision for their…

  4. Accelerated Schools as Professional Learning Communities.

    ERIC Educational Resources Information Center

    Biddle, Julie K.

    The goal of the Accelerated Schools Project (ASP) is to develop schools in which all children achieve at high levels and all members of the school community engage in developing and fulfilling the school's vision. But to fully implement the ASP model, a school must become a learning community that stresses relationships, shared values, and a…

  5. Vision based flight procedure stereo display system

    NASA Astrophysics Data System (ADS)

    Shen, Xiaoyun; Wan, Di; Ma, Lan; He, Yuncheng

    2008-03-01

    A virtual reality flight procedure vision system is introduced in this paper. The digital flight map database is established based on the Geographic Information System (GIS) and high definitions satellite remote sensing photos. The flight approaching area database is established through computer 3D modeling system and GIS. The area texture is generated from the remote sensing photos and aerial photographs in various level of detail. According to the flight approaching procedure, the flight navigation information is linked to the database. The flight approaching area vision can be dynamic displayed according to the designed flight procedure. The flight approaching area images are rendered in 2 channels, one for left eye images and the others for right eye images. Through the polarized stereoscopic projection system, the pilots and aircrew can get the vivid 3D vision of the flight destination approaching area. Take the use of this system in pilots preflight preparation procedure, the aircrew can get more vivid information along the flight destination approaching area. This system can improve the aviator's self-confidence before he carries out the flight mission, accordingly, the flight safety is improved. This system is also useful in validate the visual flight procedure design, and it helps to the flight procedure design.

  6. Visual function at altitude under night vision assisted conditions.

    PubMed

    Vecchi, Diego; Morgagni, Fabio; Guadagno, Anton G; Lucertini, Marco

    2014-01-01

    Hypoxia, even mild, is known to produce negative effects on visual function, including decreased visual acuity and sensitivity to contrast, mostly in low light. This is of special concern when night vision devices (NVDs) are used during flight because they also provide poor images in terms of resolution and contrast. While wearing NVDs in low light conditions, 16 healthy male aviators were exposed to a simulated altitude of 12,500 ft in a hypobaric chamber. Snellen visual acuity decreased in normal light from 28.5 +/- 4.2/20 (normoxia) to 37.2 +/- 7.4/20 (hypoxia) and, in low light, from 33.8 +/- 6.1/20 (normoxia) to 42.2 +/- 8.4/20 (hypoxia), both at a significant level. An association was found between blood oxygen saturation and visual acuity without significance. No changes occurred in terms of sensitivity to contrast. Our data demonstrate that mild hypoxia is capable of affecting visual acuity and the photopic/high mesopic range of NVD-aided vision. This may be due to several reasons, including the sensitivity to hypoxia of photoreceptors and other retinal cells. Contrast sensitivity is possibly preserved under NVD-aided vision due to its dependency on the goggles' gain.

  7. Proteus: a reconfigurable computational network for computer vision

    NASA Astrophysics Data System (ADS)

    Haralick, Robert M.; Somani, Arun K.; Wittenbrink, Craig M.; Johnson, Robert; Cooper, Kenneth; Shapiro, Linda G.; Phillips, Ihsin T.; Hwang, Jenq N.; Cheung, William; Yao, Yung H.; Chen, Chung-Ho; Yang, Larry; Daugherty, Brian; Lorbeski, Bob; Loving, Kent; Miller, Tom; Parkins, Larye; Soos, Steven L.

    1992-04-01

    The Proteus architecture is a highly parallel MIMD, multiple instruction, multiple-data machine, optimized for large granularity tasks such as machine vision and image processing The system can achieve 20 Giga-flops (80 Giga-flops peak). It accepts data via multiple serial links at a rate of up to 640 megabytes/second. The system employs a hierarchical reconfigurable interconnection network with the highest level being a circuit switched Enhanced Hypercube serial interconnection network for internal data transfers. The system is designed to use 256 to 1,024 RISC processors. The processors use one megabyte external Read/Write Allocating Caches for reduced multiprocessor contention. The system detects, locates, and replaces faulty subsystems using redundant hardware to facilitate fault tolerance. The parallelism is directly controllable through an advanced software system for partitioning, scheduling, and development. System software includes a translator for the INSIGHT language, a parallel debugger, low and high level simulators, and a message passing system for all control needs. Image processing application software includes a variety of point operators neighborhood, operators, convolution, and the mathematical morphology operations of binary and gray scale dilation, erosion, opening, and closing.

  8. Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.

    PubMed

    Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E

    2017-05-01

    To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.

  9. Piaget's Water-Level Task: The Impact of Vision on Performance

    ERIC Educational Resources Information Center

    Papadopoulos, Konstantinos; Koustriava, Eleni

    2011-01-01

    In the present study, the aim was to examine the differences in performance between children and adolescents with visual impairment and sighted peers in the water-level task. Twenty-eight individuals with visual impairments, 14 individuals with blindness and 14 individuals with low vision, and 28 sighted individuals participated in the present…

  10. Age related macular degeneration and visual disability.

    PubMed

    Christoforidis, John B; Tecce, Nicola; Dell'Omo, Roberto; Mastropasqua, Rodolfo; Verolino, Marco; Costagliola, Ciro

    2011-02-01

    Age-related macular degeneration (AMD) is the leading cause of central blindness or low vision among the elderly in industrialized countries. AMD is caused by a combination of genetic and environmental factors. Among modifiable environmental risk factors, cigarette smoking has been associated with both the dry and wet forms of AMD and may increase the likelihood of worsening pre-existing AMD. Despite advances, the treatment of AMD has limitations and affected patients are often referred for low vision rehabilitation to help them cope with their remaining eyesight. The characteristic visual impairment for both forms of AMD is loss of central vision (central scotoma). This loss results in severe difficulties with reading that may be only partly compensated by magnifying glasses or screen-projection devices. The loss of central vision associated with the disease has a profound impact on patient quality of life. With progressive central visual loss, patients lose their ability to perform the more complex activities of daily living. Common vision aids include low vision filters, magnifiers, telescopes and electronic aids. Low vision rehabilitation (LVR) is a new subspecialty emerging from the traditional fields of ophthalmology, optometry, occupational therapy, and sociology, with an ever-increasing impact on the usual concepts of research, education, and services for visually impaired patients. Relatively few ophthalmologists practise LVR and fewer still routinely use prismatic image relocation (IR) in AMD patients. IR is a method of stabilizing oculomotor functions with the purpose of promoting better function of preferred retinal loci (PRLs). The aim of vision rehabilitation therapy consists in the achievement of techniques designed to improve PRL usage. The use of PRLs to compensate for diseased foveae has offered hope to these patients in regaining some function. However, in a recently published meta-analysis, prism spectacles were found to be unlikely to be of substantial benefit in people with age-related macular degeneration. Prescription filters are one of the most beneficial visual aids that people with macular degeneration. In principle, one aims both at reducing short-wavelength light to reduce glare and at identifying light with specific wavelengths (colours) preferred by the patient for viewing. In both instances, such interventions result in apparent improved contrast sensitivity and better visual acuity. Although specific tests are performed to determine the best colour, tint, lens material, and type of frame for the patient's need, no scientific protocol has been developed so far to assist in prescribing tinted or selective transmission lenses . Magnifying optical lenses are available in a wide range of dioptric powers and are made from materials that correct for weight (plastic), thickness (high index), spherical aberrations (aspherical), and variable light intensities (photochromatic). These lenses can be used as loose lenses, mounted on optical frames, or used with a wide variety of attachments. As the dioptric power of plus lenses increases, the viewing distance of the target decreases, hence their usefulness mainly for tasks requiring near resolution acuity, like reading. Magnification can also be achieved with the use of telescopic devices that are built of two or more plus and (or) minus (minifying) optical lenses. Normal resolution acuity levels can be achieved with these devices for all viewing distances. Therefore, all telescopic devices are useful only for stationary patient tasks that do not require mobility and orientation. Electronic magnification has the great advantage over plus lenses of producing an acuity reserve enabling reading skills for almost all levels of visual acuity. The additional benefit provided is preservation of binocularity, even at high levels of visual disparity between the two eyes. Vision rehabilitation can help patients to maximize their remaining vision and adapt to activities of daily living. The support of the patient's social network is critical to patient's well-being as patients adjust to being partially sighted.

  11. Image Understanding Architecture

    DTIC Science & Technology

    1991-09-01

    architecture to support real-time, knowledge -based image understanding , and develop the software support environment that will be needed to utilize...NUMBER OF PAGES Image Understanding Architecture, Knowledge -Based Vision, AI Real-Time Computer Vision, Software Simulator, Parallel Processor IL PRICE... information . In addition to sensory and knowledge -based processing it is useful to introduce a level of symbolic processing. Thus, vision researchers

  12. Bullying in German Adolescents: Attending Special School for Students with Visual Impairment

    ERIC Educational Resources Information Center

    Pinquart, Martin; Pfeiffer, Jens P.

    2011-01-01

    The present study analysed bullying in German adolescents with and without visual impairment. Ninety-eight adolescents with vision loss from schools for students with visual impairment, of whom 31 were blind and 67 had low vision, were compared with 98 sighted peers using a matched-pair design. Students with low vision reported higher levels of…

  13. Detecting personnel around UGVs using stereo vision

    NASA Astrophysics Data System (ADS)

    Bajracharya, Max; Moghaddam, Baback; Howard, Andrew; Matthies, Larry H.

    2008-04-01

    Detecting people around unmanned ground vehicles (UGVs) to facilitate safe operation of UGVs is one of the highest priority issues in the development of perception technology for autonomous navigation. Research to date has not achieved the detection ranges or reliability needed in deployed systems to detect upright pedestrians in flat, relatively uncluttered terrain, let alone in more complex environments and with people in postures that are more difficult to detect. Range data is essential to solve this problem. Combining range data with high resolution imagery may enable higher performance than range data alone because image appearance can complement shape information in range data and because cameras may offer higher angular resolution than typical range sensors. This makes stereo vision a promising approach for several reasons: image resolution is high and will continue to increase, the physical size and power dissipation of the cameras and computers will continue to decrease, and stereo cameras provide range data and imagery that are automatically spatially and temporally registered. We describe a stereo vision-based pedestrian detection system, focusing on recent improvements to a shape-based classifier applied to the range data, and present frame-level performance results that show great promise for the overall approach.

  14. Evaluating and Stimulating Vision in the Multiply Impaired.

    ERIC Educational Resources Information Center

    Jose, Randall T.; And Others

    1980-01-01

    Techniques for evaluating the multiply impaired child's functional level of vision are described and a sequence of visual stimulation instruction for children with visual impairments is presented. (PHR)

  15. Gender-related effects of vision impairment characteristics on depression in Korea.

    PubMed

    Park, Hye Won; Lee, Wanhyung; Yoon, Jin-Ha

    2018-04-01

    To investigate the gender-specific associations between perceived vision impairment and symptoms of depression. We used the data from the 2012 Korean Longitudinal Study of Aging database of 7448 individuals aged 45 years and older. Questionnaires assessing depression symptoms and perceived visual impairment at near, distance, and in general were administered. Logistic regression analyses were used to evaluate if visual impairment could lead to depression, adjusting for the potential confounders of age, socioeconomic status (household income, education level, marital status, and employment status), and health behaviors (alcohol consumption, smoking, and physical activity level) after gender stratification. Perceived general and near vision impairment were significantly associated with symptoms of depression in males (odds ratio [OR] = 2.78 and 2.54; 95% confidence interval [CI], 1.91-4.04 and 1.78-3.63). Perceived general and distance vision impairment were significantly associated with symptoms of depression in females (OR = 2.16 and 2.08; 95% CI, 1.67-2.79 and 1.61-2.69). General sight with near vision impairment in males and general sight with distance vision impairment in females could be stronger predictors of depression than other vision impairment combinations (area under the receiver operating characteristic curve [AUROC], 0.6461; p = 0.0425 in males; AUROC, 0.6270; p = 0.0318 in females). Conclusion Gender differences were found in the characteristics of visual impairment on symptoms of depression. Ophthalmologists should be aware that near vision impairment in males and distance vision impairment in females have an adjunctive effect that might contribute to symptoms of depression.

  16. The Effects of Dietary Carotenoid Supplementation and Retinal Carotenoid Accumulation on Vision-Mediated Foraging in the House Finch

    PubMed Central

    Toomey, Matthew B.; McGraw, Kevin J.

    2011-01-01

    Background For many bird species, vision is the primary sensory modality used to locate and assess food items. The health and spectral sensitivities of the avian visual system are influenced by diet-derived carotenoid pigments that accumulate in the retina. Among wild House Finches (Carpodacus mexicanus), we have found that retinal carotenoid accumulation varies significantly among individuals and is related to dietary carotenoid intake. If diet-induced changes in retinal carotenoid accumulation alter spectral sensitivity, then they have the potential to affect visually mediated foraging performance. Methodology/Principal Findings In two experiments, we measured foraging performance of house finches with dietarily manipulated retinal carotenoid levels. We tested each bird's ability to extract visually contrasting food items from a matrix of inedible distracters under high-contrast (full) and dimmer low-contrast (red-filtered) lighting conditions. In experiment one, zeaxanthin-supplemented birds had significantly increased retinal carotenoid levels, but declined in foraging performance in the high-contrast condition relative to astaxanthin-supplemented birds that showed no change in retinal carotenoid accumulation. In experiments one and two combined, we found that retinal carotenoid concentrations predicted relative foraging performance in the low- vs. high-contrast light conditions in a curvilinear pattern. Performance was positively correlated with retinal carotenoid accumulation among birds with low to medium levels of accumulation (∼0.5–1.5 µg/retina), but declined among birds with very high levels (>2.0 µg/retina). Conclusion/Significance Our results suggest that carotenoid-mediated spectral filtering enhances color discrimination, but that this improvement is traded off against a reduction in sensitivity that can compromise visual discrimination. Thus, retinal carotenoid levels may be optimized to meet the visual demands of specific behavioral tasks and light environments. PMID:21747917

  17. Image gathering, coding, and processing: End-to-end optimization for efficient and robust acquisition of visual information

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Fales, Carl L.

    1990-01-01

    Researchers are concerned with the end-to-end performance of image gathering, coding, and processing. The applications range from high-resolution television to vision-based robotics, wherever the resolution, efficiency and robustness of visual information acquisition and processing are critical. For the presentation at this workshop, it is convenient to divide research activities into the following two overlapping areas: The first is the development of focal-plane processing techniques and technology to effectively combine image gathering with coding, with an emphasis on low-level vision processing akin to the retinal processing in human vision. The approach includes the familiar Laplacian pyramid, the new intensity-dependent spatial summation, and parallel sensing/processing networks. Three-dimensional image gathering is attained by combining laser ranging with sensor-array imaging. The second is the rigorous extension of information theory and optimal filtering to visual information acquisition and processing. The goal is to provide a comprehensive methodology for quantitatively assessing the end-to-end performance of image gathering, coding, and processing.

  18. Challenges towards realization of health care sector goals of Tanzania development vision 2025: training and deployment of graduate human resource for health.

    PubMed

    Siril, Nathanael; Kiwara, Angwara; Simba, Daud

    2013-06-01

    Human resource for health (HRH) is an essential building block for effective and efficient health care system. In Tanzania this component is faced by many challenges which in synergy with others make the health care system inefficient. In vision 2025 the country recognizes the importance of the health care sector in attaining quality livelihood for its citizens. The vision is in its 13th year since its launch. Given the central role of HRH in attainment of this vision, how the HRH is trained and deployed deserves a deeper understanding. To analyze the factors affecting training and deployment process of graduate level HRH of three core cadres; Medical Doctors, Doctor of Dental Surgery and Bachelor of Pharmacy towards realization of development vision 2025. Explorative study design in five training institutions for health and Ministry of Health and Social Welfare (MoHSW) headquarters utilizing in-depth interviews, observations and review of available documents methodology. The training Institutions which are cornerstone for HRH training are understaffed, underfunded (donor dependent), have low admitting capacities and lack co-ordination with other key stakeholders dealing with health. The deployment of graduate level HRH is affected by; limited budget, decision on deployment handled by another ministry rather than MoHSW, competition between health care sector and other sectors and lack of co-ordination between employer, trainers and other key health care sector stakeholders. Awareness on vision 2025 is low in the training institutions. For the vision 2025 health care sector goals to be realized well devised strategies on raising its awareness in the training institutions is recommended. Quality livelihood as stated in vision 2025 will be a forgotten dream if the challenges facing the training and deployment of graduate level HRH will not be addressed timely. It is the authors' view that reduction of donor dependency syndrome, extension of retirement age for academic Staffs in the training institutions for health and synergizing the training and deployment of the graduate level HRH can be among the initial strategies towards addressing these challenges.

  19. The Relationship of Some Personality and Individual Characteristics with an Individual's Commitment to an Ideal Vision for Performance Improvement.

    ERIC Educational Resources Information Center

    Watkins, Ryan

    2001-01-01

    Examined the relationship among specified personality and individual characteristics of university students with their level of commitment to a measurable, results-focused statement of an ideal vision. Discusses locus of control, generativity, self-efficacy, values, and risk taking in the use of an ideal vision for strategic planning, needs…

  20. Prevalence and causes of low vision and blindness in Baotou

    PubMed Central

    Zhang, Guisen; Li, Yan; Teng, Xuelong; Wu, Qiang; Gong, Hui; Ren, Fengmei; Guo, Yuxia; Liu, Lei; Zhang, Han

    2016-01-01

    Abstract The aim of this study was to investigate the prevalence and causes of low vision and blindness in Baotou, Inner Mongolia. A cross-sectional study was carried out. Multistage sampling was used to select samples. The visual acuity was estimated using LogMAR and corrected by pinhole as best-corrected visual acuity. There were 7000 samples selected and 5770 subjects included in this investigation. The overall bilateral prevalence rates of low vision and blindness were 3.66% (95% CI: 3.17–4.14) and 0.99% (95% CI: 0.73–1.24), respectively. The prevalence of bilateral low vision, blindness, and visual impairment increased with age and decreased with education level. The main leading cause of low vision and blindness was cataract. Diabetic retinopathy and age-related macular degeneration were found to be the second leading causes of blindness in Baotou. The low vision and blindness were more prevalent in elderly people and subjects with low education level in Baotou. Cataract was the main cause for visual impairment and more attention should be paid to fundus diseases. In order to prevent blindness, much more eye care programs should be established. PMID:27631267

  1. Prevalence and causes of low vision and blindness in Baotou: A cross-sectional study.

    PubMed

    Zhang, Guisen; Li, Yan; Teng, Xuelong; Wu, Qiang; Gong, Hui; Ren, Fengmei; Guo, Yuxia; Liu, Lei; Zhang, Han

    2016-09-01

    The aim of this study was to investigate the prevalence and causes of low vision and blindness in Baotou, Inner Mongolia.A cross-sectional study was carried out. Multistage sampling was used to select samples. The visual acuity was estimated using LogMAR and corrected by pinhole as best-corrected visual acuity.There were 7000 samples selected and 5770 subjects included in this investigation. The overall bilateral prevalence rates of low vision and blindness were 3.66% (95% CI: 3.17-4.14) and 0.99% (95% CI: 0.73-1.24), respectively. The prevalence of bilateral low vision, blindness, and visual impairment increased with age and decreased with education level. The main leading cause of low vision and blindness was cataract. Diabetic retinopathy and age-related macular degeneration were found to be the second leading causes of blindness in Baotou.The low vision and blindness were more prevalent in elderly people and subjects with low education level in Baotou. Cataract was the main cause for visual impairment and more attention should be paid to fundus diseases. In order to prevent blindness, much more eye care programs should be established.

  2. Field of Vision Influences Sensory-Motor Control of Skilled and Less-Skilled Dart Players

    PubMed Central

    Rienhoff, Rebecca; Baker, Joseph; Fischer, Lennart; Strauss, Bernd; Schorer, Jörg

    2012-01-01

    One characteristic of perceptual expertise in sport and other domains is known as ’the quiet eye', which assumes that fixated information is processed during gaze stability and insufficient spatial information leads to a decrease in performance. The aims of this study were a) replicating inter- and intra-group variability and b) investigating the extent to which quiet eye supports information pick-up of varying fields of vision (i.e., central versus peripheral) using a specific eye-tracking paradigm to compare different skill levels in a dart throwing task. Differences between skill levels were replicated at baseline, but no significant differences in throwing performance were revealed among the visual occlusion conditions. Findings are generally in line with the association between quiet eye duration and aiming performance, but raise questions regarding the relevance of central vision information pick-up for the quiet eye. Key pointsInvestigation of throwing performance and quiet eye duration in dart throwing under several vision conditionsFirst investigation using a dynamic occlusion paradigm, manipulating field of vision in situReplication of previous findings concerning throwing performance and quiet eye durationNew insights about the role of central (and peripheral) vision concerning the quiet eye phenomena PMID:24149366

  3. Relevance feedback-based building recognition

    NASA Astrophysics Data System (ADS)

    Li, Jing; Allinson, Nigel M.

    2010-07-01

    Building recognition is a nontrivial task in computer vision research which can be utilized in robot localization, mobile navigation, etc. However, existing building recognition systems usually encounter the following two problems: 1) extracted low level features cannot reveal the true semantic concepts; and 2) they usually involve high dimensional data which require heavy computational costs and memory. Relevance feedback (RF), widely applied in multimedia information retrieval, is able to bridge the gap between the low level visual features and high level concepts; while dimensionality reduction methods can mitigate the high-dimensional problem. In this paper, we propose a building recognition scheme which integrates the RF and subspace learning algorithms. Experimental results undertaken on our own building database show that the newly proposed scheme appreciably enhances the recognition accuracy.

  4. The Vision Is Set, Now Help Chronicle the Change

    ERIC Educational Resources Information Center

    Woodin, Terry; Feser, Jason; Herrera, Jose

    2012-01-01

    The Vision and Change effort to explore and implement needed changes in undergraduate biology education has been ongoing since 2006. It is now time to take stock of changes that have occurred at the faculty and single-course levels, and to consider how to accomplish the larger-scale changes needed at departmental and institutional levels. This…

  5. The Social Lives of Canadian Youths with Visual Impairments

    ERIC Educational Resources Information Center

    Gold, Deborah; Shaw, Alexander; Wolffe, Karen

    2010-01-01

    This survey of the social and leisure experiences of Canadian youths with visual impairments found that, in general, youths with low vision experienced more social challenges than did their peers who were blind. Levels of social support were not found to differ on the basis of level of vision, sex, or age. (Contains 1 figure and 1 table.)

  6. Unification and Enhancement of Planetary Robotic Vision Ground Processing: The EC FP7 Project PRoVisG

    NASA Astrophysics Data System (ADS)

    Paar, G.

    2009-04-01

    At present, mainly the US have realized planetary space missions with essential robotics background. Joining institutions, companies and universities from different established groups in Europe and two relevant players from the US, the EC FP7 Project PRoVisG started in autumn 2008 to demonstrate the European ability of realizing high-level processing of robotic vision image products from the surface of planetary bodies. PRoVisG will build a unified European framework for Robotic Vision Ground Processing. State-of-art computer vision technology will be collected inside and outside Europe to better exploit the image data gathered during past, present and future robotic space missions to the Moon and the Planets. This will lead to a significant enhancement of the scientific, technologic and educational outcome of such missions. We report on the main PRoVisG objectives and the development status: - Past, present and future planetary robotic mission profiles are analysed in terms of existing solutions and requirements for vision processing - The generic processing chain is based on unified vision sensor descriptions and processing interfaces. Processing components available at the PRoVisG Consortium Partners will be completed by and combined with modules collected within the international computer vision community in the form of Announcements of Opportunity (AOs). - A Web GIS is developed to integrate the processing results obtained with data from planetary surfaces into the global planetary context. - Towards the end of the 39 month project period, PRoVisG will address the public by means of a final robotic field test in representative terrain. The European tax payers will be able to monitor the imaging and vision processing in a Mars - similar environment, thus getting an insight into the complexity and methods of processing, the potential and decision making of scientific exploitation of such data and not least the elegancy and beauty of the resulting image products and their visualization. - The educational aspect is addressed by two summer schools towards the end of the project, presenting robotic vision to the students who are future providers of European science and technology, inside and outside the space domain.

  7. Influence of retinopathy on the achromatic and chromatic vision of patients with type 2 diabetes

    PubMed Central

    2014-01-01

    Background Luminance contrast sensitivity and colour vision are considered to have great predictive value in the evaluation of type 2 diabetic retinopathy. However, these two visual characteristics have seldom been investigated in the same group of patients. In the present study we measured contrast sensitivity and colour vision in a group of patients with type 2 diabetes and correlated the results with estimates of common metabolic markers for the disease. A subgroup of the patients had no clinical signs of retinopathy. Methods The vision of 27 patients (n = 50 eyes) with type 2 diabetes, with retinopathy (n = 20 eyes), or without retinopathy (n = 30 eyes) were evaluated using two psychophysical tests, the Farnsworth–Munsell 100 hue test (FM 100), and measurements of the luminance contrast sensitivity at 11 spatial frequencies. The results were compared with measurements obtained from an age-matched control group (n = 32), and were correlated with the level of glycated haemoglobin, glycaemic level, and time of disease onset. Signs of retinopathy were identified during the ophthalmological examinations. Results Contrast sensitivity and colour vision impairments were present at different levels in diabetes patients. Eyes with retinopathy showed more severe vision loss than eyes without retinopathy. The FM 100 test was more sensitive for separation of patients from controls. Colour vision loss had no colour axes preference. The contrast sensitivity test appeared to have some advantage in differentiating patients with retinopathy from patients without retinopathy. Conclusions Both methods can be useful to follow the visual function of diabetic patients and should be used together to discriminate patients from controls, as well as to identify early signs of retinal damage. PMID:25174264

  8. Functional Outcomes of the Low Vision Depression Prevention Trial in Age-Related Macular Degeneration.

    PubMed

    Deemer, Ashley D; Massof, Robert W; Rovner, Barry W; Casten, Robin J; Piersol, Catherine V

    2017-03-01

    To compare the efficacy of behavioral activation (BA) plus low vision rehabilitation with an occupational therapist (OT-LVR) with supportive therapy (ST) on visual function in patients with age-related macular degeneration (AMD). Single-masked, attention-controlled, randomized clinical trial with AMD patients with subsyndromal depressive symptoms (n = 188). All subjects had two outpatient low vision rehabilitation optometry visits, then were randomized to in-home BA + OT-LVR or ST. Behavioral activation is a structured behavioral treatment aiming to increase adaptive behaviors and achieve valued goals. Supportive therapy is a nondirective, psychological treatment that provides emotional support and controls for attention. Functional vision was assessed with the activity inventory (AI) in which participants rate the difficulty level of goals and corresponding tasks. Participants were assessed at baseline and 4 months. Improvements in functional vision measures were seen in both the BA + OT-LVR and ST groups at the goal level (d = 0.71; d = 0.56 respectively). At the task level, BA + OT-LVR patients showed more improvement in reading, inside-the-home tasks and outside-the-home tasks, when compared to ST patients. The greatest effects were seen in the BA + OT-LVR group in subjects with a visual acuity ≥20/70 (d = 0.360 reading; d = 0.500 inside the home; d = 0.468 outside the home). Based on the trends of the AI data, we suggest that BA + OT-LVR services, provided by an OT in the patient's home following conventional low vision optometry services, are more effective than conventional optometric low vision services alone for those with mild visual impairment. (ClinicalTrials.gov number, NCT00769015.).

  9. Challenge of the Future: Visions and Versions.

    ERIC Educational Resources Information Center

    Conboy, William A., Ed.

    This book presents background information and approximately 40 articles on various aspects of the future. It is intended for use as a textbook and/or reader in advanced high school or college level future studies courses. The objectives are to help students of the future examine major problems and issues and to encourage them to devise new models…

  10. Global Vision, Local Reality: Transforming Pre-Primary Teacher Training in Tanzania

    ERIC Educational Resources Information Center

    Wilinski, Bethany; Nguyen, Cuong Huy; Landgraf, Jessica M.

    2016-01-01

    Global attention to early childhood education (ECE) has led to an increased focus on ECE teacher training as a critical component of providing young children with access to high-quality ECE programs. In this paper, we ask how Tanzanian stakeholders at different levels of implementation experienced and responded to efforts to build capacity in…

  11. Modelling Subjectivity in Visual Perception of Orientation for Image Retrieval.

    ERIC Educational Resources Information Center

    Sanchez, D.; Chamorro-Martinez, J.; Vila, M. A.

    2003-01-01

    Discussion of multimedia libraries and the need for storage, indexing, and retrieval techniques focuses on the combination of computer vision and data mining techniques to model high-level concepts for image retrieval based on perceptual features of the human visual system. Uses fuzzy set theory to measure users' assessments and to capture users'…

  12. Rethinking Engineering Design and Decision Making in Response to Economic, Social, and Environmental Crises

    ERIC Educational Resources Information Center

    Vanderburg, Willem H.

    2009-01-01

    High levels of specialization have created knowledge with little or no "peripheral vision," and the resulting "blind spots" are causing many "collisions" with human life, society, and the biosphere. Each discipline and specialty must be equipped with a "map" showing its connections to everything else, but especially the negative consequences that…

  13. Teachers' Learning to Facilitate High-Level Student Thinking: Impact of a Video-Based Professional Development

    ERIC Educational Resources Information Center

    Tekkumru-Kisa, Miray; Stein, Mary Kay; Coker, Ryan

    2018-01-01

    Attaining the vision for science teaching and learning emphasized in the Framework for K-12 Science Education and the next generation science standards (NGSS) will require major shifts in teaching practices in many science classrooms. As NGSS-inspired cognitively demanding tasks begin to appear in more and more science classrooms, facilitating…

  14. How Dogmatic Beliefs Harm Creativity and Higher-Level Thinking. Educational Psychology Series

    ERIC Educational Resources Information Center

    Ambrose, Don, Ed.; Sternberg, Robert J., Ed.

    2011-01-01

    In a world plagued by enormous, complex problems requiring long-range vision and interdisciplinary insights, the need to attend to the influence of dogmatic thinking on the development of high ability and creative intelligence is pressing. This volume introduces the problem of dogmatism broadly, explores the nature and nuances of dogmatic thinking…

  15. The Application of Virtex-II Pro FPGA in High-Speed Image Processing Technology of Robot Vision Sensor

    NASA Astrophysics Data System (ADS)

    Ren, Y. J.; Zhu, J. G.; Yang, X. Y.; Ye, S. H.

    2006-10-01

    The Virtex-II Pro FPGA is applied to the vision sensor tracking system of IRB2400 robot. The hardware platform, which undertakes the task of improving SNR and compressing data, is constructed by using the high-speed image processing of FPGA. The lower level image-processing algorithm is realized by combining the FPGA frame and the embedded CPU. The velocity of image processing is accelerated due to the introduction of FPGA and CPU. The usage of the embedded CPU makes it easily to realize the logic design of interface. Some key techniques are presented in the text, such as read-write process, template matching, convolution, and some modules are simulated too. In the end, the compare among the modules using this design, using the PC computer and using the DSP, is carried out. Because the high-speed image processing system core is a chip of FPGA, the function of which can renew conveniently, therefore, to a degree, the measure system is intelligent.

  16. Deep hierarchies in the primate visual cortex: what can we learn for computer vision?

    PubMed

    Krüger, Norbert; Janssen, Peter; Kalkan, Sinan; Lappe, Markus; Leonardis, Ales; Piater, Justus; Rodríguez-Sánchez, Antonio J; Wiskott, Laurenz

    2013-08-01

    Computational modeling of the primate visual system yields insights of potential relevance to some of the challenges that computer vision is facing, such as object recognition and categorization, motion detection and activity recognition, or vision-based navigation and manipulation. This paper reviews some functional principles and structures that are generally thought to underlie the primate visual cortex, and attempts to extract biological principles that could further advance computer vision research. Organized for a computer vision audience, we present functional principles of the processing hierarchies present in the primate visual system considering recent discoveries in neurophysiology. The hierarchical processing in the primate visual system is characterized by a sequence of different levels of processing (on the order of 10) that constitute a deep hierarchy in contrast to the flat vision architectures predominantly used in today's mainstream computer vision. We hope that the functional description of the deep hierarchies realized in the primate visual system provides valuable insights for the design of computer vision algorithms, fostering increasingly productive interaction between biological and computer vision research.

  17. A nationwide population-based study of low vision and blindness in South Korea.

    PubMed

    Park, Shin Hae; Lee, Ji Sung; Heo, Hwan; Suh, Young-Woo; Kim, Seung-Hyun; Lim, Key Hwan; Moon, Nam Ju; Lee, Sung Jin; Park, Song Hee; Baek, Seung-Hee

    2014-12-18

    To investigate the prevalence and associated risk factors of low vision and blindness in the Korean population. This cross-sectional, population-based study examined the ophthalmologic data of 22,135 Koreans aged ≥5 years from the fifth Korea National Health and Nutrition Examination Survey (KNHANES V, 2010-2012). According to the World Health Organization criteria, blindness was defined as visual acuity (VA) less than 20/400 in the better-seeing eye, and low vision as VA of 20/60 or worse but 20/400 or better in the better-seeing eye. The prevalence rates were calculated from either presenting VA (PVA) or best-corrected VA (BCVA). Multivariate regression analysis was conducted for adults aged ≥20 years. The overall prevalence rates of PVA-defined low vision and blindness were 4.98% and 0.26%, respectively, and those of BCVA-defined low vision and blindness were 0.46% and 0.05%, respectively. Prevalence increased rapidly above the age of 70 years. For subjects aged ≥70 years, the population-weighted prevalence rates of low vision, based on PVA and BCVA, were 12.85% and 3.87%, respectively, and the corresponding rates of blindness were 0.49% and 0.42%, respectively. The presenting vision problems were significantly associated with age (younger adults or elderly subjects), female sex, low educational level, and lowest household income, whereas the best-corrected vision problems were associated with age ≥ 70 years, a low educational level, and rural residence. This population-based study provides useful information for planning optimal public eye health care services in South Korea. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  18. Color Vision Changes and Effects of High Contrast Visor Use at Simulated Cabin Altitudes

    DTIC Science & Technology

    2016-06-08

    under these conditions. Following Institutional Review Board approval, a reduced oxygen breathing device was used to expose subjects with normal...vision, high contrast visor, reduced oxygen breathing device 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18. NUMBER OF...in further degradation of color vision under these conditions. Following Institutional Review Board approval, a reduced oxygen breathing device was

  19. Office of the CIO: Setting the Vision

    NASA Technical Reports Server (NTRS)

    Rinaldi, James J.

    2006-01-01

    This slide presentation reviews the vision of the Office of JPL's Chief Information Officer for future of information technology (IT) at JPL. This includes a strong working relation with industry to provide cost efficient and effective IT services. This includes a vision of taking desktop to the next level and the process to achieve it and ensuring that JPL becomes a world class IT provider.

  20. Assessing color vision loss among solvent-exposed workers.

    PubMed

    Mergler, D; Blain, L

    1987-01-01

    Acquired color vision loss has been associated with exposure to organic solvents in the workplace. However, not all tests of chromatic discrimination loss are designed to detect acquired, as opposed to congenital, loss. The Lanthony D-15 desaturated panel (D-15-d), a simple 15 cap color arrangement test, designed to identify mild acquired dyschromatopsia, can be administered rapidly in the field, under standard conditions. The objective of the present study was to evaluate the D-15-d among 23 solvent-exposed workers of a paint manufacturing plant, by comparing the results obtained with the D-15-d to those obtained with the Farnsworth-Munsell 100 Hue (FM-100), a highly sensitive measure of color vision loss. The D-15-d revealed a significantly higher prevalence of dyschromatopsia among the ten highly exposed workers (80%) as compared to the 13 moderately exposed workers (30.8%); FM-100 results revealed one false positive. All dyschromatopic workers presented blue-yellow loss; the FM-100 detected eight complex patterns, while the D-15-d identified 5. Comparison of D-15-d and FM-100 scores were highly correlated (corr. coeff. 0.87; p less than 0.001). Multiple regression analyses showed both scores to be significantly related to age and exposure level. The findings of this study indicate that the D-15-d is an adequate instrument for field study batteries. However, the FM-100 should be used for more detailed assessment.

  1. School Vision of Learning: Urban Setting

    ERIC Educational Resources Information Center

    Guy, Tiffany A.

    2010-01-01

    In this paper, the author develops her school vision of learning. She explains the theories she used to help develop the vision. The author then goes into detail on the methods she will use to make her vision for a school that prepares urban students for a successful life after high school. She takes into account all the stakeholders and how they…

  2. Vision and quality-of-life.

    PubMed Central

    Brown, G C

    1999-01-01

    OBJECTIVE: To determine the relationship of visual acuity loss to quality of life. DESIGN: Three hundred twenty-five patients with visual loss to a minimum of 20/40 or greater in at least 1 eye were interviewed in a standardized fashion using a modified VF-14, questionnaire. Utility values were also obtained using both the time trade-off and standard gamble methods of utility assessment. MAIN OUTCOME MEASURES: Best-corrected visual acuity was correlated with the visual function score on the modified VF-14 questionnaire, as well as with utility values obtained using both the time trade-off and standard gamble methods. RESULTS: Decreasing levels of vision in the eye with better acuity correlated directly with decreasing visual function scores on the modified VF-14 questionnaire, as did decreasing utility values using the time trade-off method of utility evaluation. The standard gamble method of utility evaluation was not as directly correlated with vision as the time trade-off method. Age, level of education, gender, race, length of time of visual loss, and the number of associated systemic comorbidities did not significantly affect the time trade-off utility values associated with visual loss in the better eye. The level of reduced vision in the better eye, rather than the specific disease process causing reduced vision, was related to mean utility values. The average person with 20/40 vision in the better seeing eye was willing to trade 2 of every 10 years of life in return for perfect vision (utility value of 0.8), while the average person with counting fingers vision in the better eye was willing to trade approximately 5 of every 10 remaining years of life (utility value of 0.52) in return for perfect vision. CONCLUSIONS: The time trade-off method of utility evaluation appears to be an effective method for assessing quality of life associated with visual loss. Time trade-off utility values decrease in direct conjunction with decreasing vision in the better-seeing eye. Unlike the modified VF-14 test and its counterparts, utility values allow the quality of life associated with visual loss to be more readily compared to the quality of life associated with other health (disease) states. This information can be employed for cost-effective analyses that objectively compare evidence-based medicine, patient-based preferences and sound econometric principles across all specialties in health care. PMID:10703139

  3. Signatures of functional constraint at aye-aye opsin genes: the potential of adaptive color vision in a nocturnal primate.

    PubMed

    Perry, George H; Martin, Robert D; Verrelli, Brian C

    2007-09-01

    While color vision perception is thought to be adaptively correlated with foraging efficiency for diurnal mammals, those that forage exclusively at night may not need color vision nor have the capacity for it. Indeed, although the basic condition for mammals is dichromacy, diverse nocturnal mammals have only monochromatic vision, resulting from functional loss of the short-wavelength sensitive opsin gene. However, many nocturnal primates maintain intact two opsin genes and thus have dichromatic capacity. The evolutionary significance of this surprising observation has not yet been elucidated. We used a molecular population genetics approach to test evolutionary hypotheses for the two intact opsin genes of the fully nocturnal aye-aye (Daubentonia madagascariensis), a highly unusual and endangered Madagascar primate. No evidence of gene degradation in either opsin gene was observed for any of 8 aye-aye individuals examined. Furthermore, levels of nucleotide diversity for opsin gene functional sites were lower than those for 15 neutrally evolving intergenic regions (>25 kb in total), which is consistent with a history of purifying selection on aye-aye opsin genes. The most likely explanation for these findings is that dichromacy is advantageous for aye-ayes despite their nocturnal activity pattern. We speculate that dichromatic nocturnal primates may be able to perceive color while foraging under moonlight conditions, and suggest that behavioral and ecological comparisons among dichromatic and monochromatic nocturnal primates will help to elucidate the specific activities for which color vision perception is advantageous.

  4. The severity of the visual impairment and practice matter for drawing ability in children.

    PubMed

    Vinter, Annie; Bonin, Patrick; Morgan, Pascal

    2018-07-01

    Astonishing drawing capacities have been reported in children with early visual impairments. However, most of the evidence relies on single case studies. Hitherto, no study has systematically jointly investigated, in these children, the role of (1) the severity of the visual handicap, (2) age and (3) practice in drawing. The study aimed at revealing the specificities of the drawing in children deprived from vision, as compared to children with less severe visual handicap and to sighted children performing under haptic or usual visual control. 148 children aged 6-14 years had to produce 12 drawings of familiar objects. 38 had a severe visual impairment, 41 suffered from low vision, and 69 were sighted children performing either under visual condition or blindfolded under haptic control. Recognizability and other characteristics of the drawings were highly dependent on the child's degree of vision and level of drawing practice, and progressed with chronological age more clearly in the sighted children or those with low vision than in those deprived of vision. The study confirmed that all groups showed significant drawing ability, even the group totally deprived of visual experience. Furthermore, the specificities of the drawings produced by visually-impaired children appeared clearly related to their practice and the severity of their visual impairment. This should incite parents and professionals to encourage these children to practice drawing as early as possible. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. FPGA-Based Multimodal Embedded Sensor System Integrating Low- and Mid-Level Vision

    PubMed Central

    Botella, Guillermo; Martín H., José Antonio; Santos, Matilde; Meyer-Baese, Uwe

    2011-01-01

    Motion estimation is a low-level vision task that is especially relevant due to its wide range of applications in the real world. Many of the best motion estimation algorithms include some of the features that are found in mammalians, which would demand huge computational resources and therefore are not usually available in real-time. In this paper we present a novel bioinspired sensor based on the synergy between optical flow and orthogonal variant moments. The bioinspired sensor has been designed for Very Large Scale Integration (VLSI) using properties of the mammalian cortical motion pathway. This sensor combines low-level primitives (optical flow and image moments) in order to produce a mid-level vision abstraction layer. The results are described trough experiments showing the validity of the proposed system and an analysis of the computational resources and performance of the applied algorithms. PMID:22164069

  6. FPGA-based multimodal embedded sensor system integrating low- and mid-level vision.

    PubMed

    Botella, Guillermo; Martín H, José Antonio; Santos, Matilde; Meyer-Baese, Uwe

    2011-01-01

    Motion estimation is a low-level vision task that is especially relevant due to its wide range of applications in the real world. Many of the best motion estimation algorithms include some of the features that are found in mammalians, which would demand huge computational resources and therefore are not usually available in real-time. In this paper we present a novel bioinspired sensor based on the synergy between optical flow and orthogonal variant moments. The bioinspired sensor has been designed for Very Large Scale Integration (VLSI) using properties of the mammalian cortical motion pathway. This sensor combines low-level primitives (optical flow and image moments) in order to produce a mid-level vision abstraction layer. The results are described trough experiments showing the validity of the proposed system and an analysis of the computational resources and performance of the applied algorithms.

  7. A design of optical modulation system with pixel-level modulation accuracy

    NASA Astrophysics Data System (ADS)

    Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu

    2018-01-01

    Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.

  8. Real-time high-level video understanding using data warehouse

    NASA Astrophysics Data System (ADS)

    Lienard, Bruno; Desurmont, Xavier; Barrie, Bertrand; Delaigle, Jean-Francois

    2006-02-01

    High-level Video content analysis such as video-surveillance is often limited by computational aspects of automatic image understanding, i.e. it requires huge computing resources for reasoning processes like categorization and huge amount of data to represent knowledge of objects, scenarios and other models. This article explains how to design and develop a "near real-time adaptive image datamart", used, as a decisional support system for vision algorithms, and then as a mass storage system. Using RDF specification as storing format of vision algorithms meta-data, we can optimise the data warehouse concepts for video analysis, add some processes able to adapt the current model and pre-process data to speed-up queries. In this way, when new data is sent from a sensor to the data warehouse for long term storage, using remote procedure call embedded in object-oriented interfaces to simplified queries, they are processed and in memory data-model is updated. After some processing, possible interpretations of this data can be returned back to the sensor. To demonstrate this new approach, we will present typical scenarios applied to this architecture such as people tracking and events detection in a multi-camera network. Finally we will show how this system becomes a high-semantic data container for external data-mining.

  9. An approach to integrate the human vision psychology and perception knowledge into image enhancement

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Huang, Xifeng; Ping, Jiang

    2009-07-01

    Image enhancement is very important image preprocessing technology especially when the image is captured in the poor imaging condition or dealing with the high bits image. The benefactor of image enhancement either may be a human observer or a computer vision process performing some kind of higher-level image analysis, such as target detection or scene understanding. One of the main objects of the image enhancement is getting a high dynamic range image and a high contrast degree image for human perception or interpretation. So, it is very necessary to integrate either empirical or statistical human vision psychology and perception knowledge into image enhancement. The human vision psychology and perception claims that humans' perception and response to the intensity fluctuation δu of visual signals are weighted by the background stimulus u, instead of being plainly uniform. There are three main laws: Weber's law, Weber- Fechner's law and Stevens's Law that describe this phenomenon in the psychology and psychophysics. This paper will integrate these three laws of the human vision psychology and perception into a very popular image enhancement algorithm named Adaptive Plateau Equalization (APE). The experiments were done on the high bits star image captured in night scene and the infrared-red image both the static image and the video stream. For the jitter problem in the video stream, this algorithm reduces this problem using the difference between the current frame's plateau value and the previous frame's plateau value to correct the current frame's plateau value. Considering the random noise impacts, the pixel value mapping process is not only depending on the current pixel but the pixels in the window surround the current pixel. The window size is usually 3×3. The process results of this improved algorithms is evaluated by the entropy analysis and visual perception analysis. The experiments' result showed the improved APE algorithms improved the quality of the image, the target and the surrounding assistant targets could be identified easily, and the noise was not amplified much. For the low quality image, these improved algorithms augment the information entropy and improve the image and the video stream aesthetic quality, while for the high quality image they will not debase the quality of the image.

  10. Rod phototransduction determines the trade-off of temporal integration and speed of vision in dark-adapted toads.

    PubMed

    Haldin, Charlotte; Nymark, Soile; Aho, Ann-Christine; Koskelainen, Ari; Donner, Kristian

    2009-05-06

    Human vision is approximately 10 times less sensitive than toad vision on a cool night. Here, we investigate (1) how far differences in the capacity for temporal integration underlie such differences in sensitivity and (2) whether the response kinetics of the rod photoreceptors can explain temporal integration at the behavioral level. The toad was studied as a model that allows experimentation at different body temperatures. Sensitivity, integration time, and temporal accuracy of vision were measured psychophysically by recording snapping at worm dummies moving at different velocities. Rod photoresponses were studied by ERG recording across the isolated retina. In both types of experiments, the general timescale of vision was varied by using two temperatures, 15 and 25 degrees C. Behavioral integration times were 4.3 s at 15 degrees C and 0.9 s at 25 degrees C, and rod integration times were 4.2-4.3 s at 15 degrees C and 1.0-1.3 s at 25 degrees C. Maximal behavioral sensitivity was fivefold lower at 25 degrees C than at 15 degrees C, which can be accounted for by inability of the "warm" toads to integrate light over longer times than the rods. However, the long integration time at 15 degrees C, allowing high sensitivity, degraded the accuracy of snapping toward quickly moving worms. We conclude that temporal integration explains a considerable part of all variation in absolute visual sensitivity. The strong correlation between rods and behavior suggests that the integration time of dark-adapted vision is set by rod phototransduction at the input to the visual system. This implies that there is an inexorable trade-off between temporal integration and resolution.

  11. Monocular Stereo Measurement Using High-Speed Catadioptric Tracking

    PubMed Central

    Hu, Shaopeng; Matsumoto, Yuji; Takaki, Takeshi; Ishii, Idaku

    2017-01-01

    This paper presents a novel concept of real-time catadioptric stereo tracking using a single ultrafast mirror-drive pan-tilt active vision system that can simultaneously switch between hundreds of different views in a second. By accelerating video-shooting, computation, and actuation at the millisecond-granularity level for time-division multithreaded processing in ultrafast gaze control, the active vision system can function virtually as two or more tracking cameras with different views. It enables a single active vision system to act as virtual left and right pan-tilt cameras that can simultaneously shoot a pair of stereo images for the same object to be observed at arbitrary viewpoints by switching the direction of the mirrors of the active vision system frame by frame. We developed a monocular galvano-mirror-based stereo tracking system that can switch between 500 different views in a second, and it functions as a catadioptric active stereo with left and right pan-tilt tracking cameras that can virtually capture 8-bit color 512×512 images each operating at 250 fps to mechanically track a fast-moving object with a sufficient parallax for accurate 3D measurement. Several tracking experiments for moving objects in 3D space are described to demonstrate the performance of our monocular stereo tracking system. PMID:28792483

  12. (Computer) Vision without Sight

    PubMed Central

    Manduchi, Roberto; Coughlan, James

    2012-01-01

    Computer vision holds great promise for helping persons with blindness or visual impairments (VI) to interpret and explore the visual world. To this end, it is worthwhile to assess the situation critically by understanding the actual needs of the VI population and which of these needs might be addressed by computer vision. This article reviews the types of assistive technology application areas that have already been developed for VI, and the possible roles that computer vision can play in facilitating these applications. We discuss how appropriate user interfaces are designed to translate the output of computer vision algorithms into information that the user can quickly and safely act upon, and how system-level characteristics affect the overall usability of an assistive technology. Finally, we conclude by highlighting a few novel and intriguing areas of application of computer vision to assistive technology. PMID:22815563

  13. Are middle-age blood pressure levels related to color vision impairment? The Okubo Color Study.

    PubMed

    Shoji, Takuhei; Sato, Hiroki; Chihara, Etsuo; Sakurai, Yutaka

    2015-01-01

    We sought to investigate the association between blood pressure levels and prevalence of acquired color vision impairment in middle-aged Japanese men. Participants underwent color vision testing, ophthalmological examination, standardized interview, physical record examination, and venous blood examination. Cardiovascular disease risk factors were determined based on blood and physical examination results and the interview. Logistic regression analysis was performed after adjusting for body mass index, systemic dyslipidemia, diabetes, cataract, glaucoma, smoking status, and drinking status. Of 1,042 men, 872 were eligible for the study, 130 failed the Lanthony 15-hue desaturated panel (D-15 DS) diagnosed as acquired color vision impairment 15-hue, and 31 failed the Farnsworth-Munsell 100-hue test diagnosed as acquired color vision impairment 100-hue. Diastolic blood pressure was significantly correlated with both acquired color vision impairment in 100-hue patients (adjusted odds ratio (OR) for 10-mm Hg increases = 1.42; 95% confidence interval (CI) = 1.00-2.02) and acquired color vision impairment in 15-hue patients (adjusted OR for 10-mm Hg increases = 1.25; 95% CI = 1.04-1.51). The multiple-adjusted ORs for acquired color vision impairment 100-hue patients and acquired color vision impairment 15-hue patients were 7.13 (95% CI = 1.72-27.88) and 4.37 (95% CI = 1.69-11.03), respectively, for the highest blood pressure category (systolic blood pressure ≥ 160 and diastolic blood pressure ≥ 100 mm Hg) compared with those for the lowest blood pressure category (systolic blood pressure <120 and diastolic blood pressure <80 mm Hg). Tests for trends were significant (P < 0.05) in both analyses. Hypertension in middle-aged men may negatively modify vision-associated neuronal function. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Thirty Years After Marr's Vision: Levels of Analysis in Cognitive Science.

    PubMed

    Peebles, David; Cooper, Richard P

    2015-04-01

    Thirty years after the publication of Marr's seminal book Vision (Marr, 1982) the papers in this topic consider the contemporary status of his influential conception of three distinct levels of analysis for information-processing systems, and in particular the role of the algorithmic and representational level with its cognitive-level concepts. This level has (either implicitly or explicitly) been downplayed or eliminated both by reductionist neuroscience approaches from below that seek to account for behavior from the implementation level and by Bayesian approaches from above that seek to account for behavior in purely computational-level terms. Copyright © 2015 Cognitive Science Society, Inc.

  15. A Study of Innovation: ERD Takes Pollution Prevention to a New Level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Southmayd, A.

    1999-01-20

    ERD approaches its mission with a vision of continuously exceeding customer needs and expectations and continuously improving. It's this vision of continuous improvement that drives the ERD pollution prevention program towards innovation.

  16. Visions 2025 and Linkage to NEXT

    NASA Technical Reports Server (NTRS)

    Wiscombe, W.; Lau, William K. M. (Technical Monitor)

    2002-01-01

    This talk will describe the progress to date on creating a science-driven vision for the NASA Earth Science Enterprise (ESE) in the post-2010 period. This effort began in the Fall of 2001 by organizing five science workgroups with representatives from NASA, academia and other agencies: Long-Term Climate, Medium-Term Climate, Extreme Weather, Biosphere & Ecosystems, and Solid Earth, Ice Sheets, & Sea Level. Each workgroup was directed to scope out one Big Question, including not just the science but the observational and modeling requirements, the information system requirements, and the applications and benefits to society. This first set of five Big Questions is now in hand and has been presented to the ESE Director. It includes: water resources, intraseasonal predictability, tropical cyclogenesis, invasive species, and sea level. Each of these topics will be discussed briefly. How this effort fits into the NEXT vision exercise and into Administrator O'Keefe's new vision for NASA will also be discussed.

  17. Highly polymorphic colour vision in a New World monkey with red facial skin, the bald uakari (Cacajao calvus).

    PubMed

    Corso, Josmael; Bowler, Mark; Heymann, Eckhard W; Roos, Christian; Mundy, Nicholas I

    2016-04-13

    Colour vision is highly variable in New World monkeys (NWMs). Evidence for the adaptive basis of colour vision in this group has largely centred on environmental features such as foraging benefits for differently coloured foods or predator detection, whereas selection on colour vision for sociosexual communication is an alternative hypothesis that has received little attention. The colour vision of uakaris (Cacajao) is of particular interest because these monkeys have the most dramatic red facial skin of any primate, as well as a unique fission/fusion social system and a specialist diet of seeds. Here, we investigate colour vision in a wild population of the bald uakari,C. calvus, by genotyping the X-linked opsin locus. We document the presence of a polymorphic colour vision system with an unprecedented number of functional alleles (six), including a novel allele with a predicted maximum spectral sensitivity of 555 nm. This supports the presence of strong balancing selection on different alleles at this locus. We consider different hypotheses to explain this selection. One possibility is that trichromacy functions in sexual selection, enabling females to choose high-quality males on the basis of red facial coloration. In support of this, there is some evidence that health affects facial coloration in uakaris, as well as a high prevalence of blood-borne parasitism in wild uakari populations. Alternatively, the low proportion of heterozygous female trichromats in the population may indicate selection on different dichromatic phenotypes, which might be related to cryptic food coloration. We have uncovered unexpected diversity in the last major lineage of NWMs to be assayed for colour vision, which will provide an interesting system to dissect adaptation of polymorphic trichromacy. © 2016 The Author(s).

  18. Mobile robot exploration and navigation of indoor spaces using sonar and vision

    NASA Technical Reports Server (NTRS)

    Kortenkamp, David; Huber, Marcus; Koss, Frank; Belding, William; Lee, Jaeho; Wu, Annie; Bidlack, Clint; Rodgers, Seth

    1994-01-01

    Integration of skills into an autonomous robot that performs a complex task is described. Time constraints prevented complete integration of all the described skills. The biggest problem was tuning the sensor-based region-finding algorithm to the environment involved. Since localization depended on matching regions found with the a priori map, the robot became lost very quickly. If the low level sensing of the world is not working, then high level reasoning or map making will be unsuccessful.

  19. Night Vision Goggle Training; Development and Production of Six Video Programs

    DTIC Science & Technology

    1992-11-01

    SUIUECT TERMS Multimedia Video production iS. NUMBER OF PAGES Aeral photography Night vision Videodisc 18 Image Intensification Night vision goggles...reference tool on the squadron or wing demonstrates NVG field of view, field of level. The programs run approximately ten regard, scan techniques, image...training device modalities. These The production of a videodisc that modalities include didactic and video will serve as an NVG audio-visual database

  20. Behavioral model of visual perception and recognition

    NASA Astrophysics Data System (ADS)

    Rybak, Ilya A.; Golovan, Alexander V.; Gusakova, Valentina I.

    1993-09-01

    In the processes of visual perception and recognition human eyes actively select essential information by way of successive fixations at the most informative points of the image. A behavioral program defining a scanpath of the image is formed at the stage of learning (object memorizing) and consists of sequential motor actions, which are shifts of attention from one to another point of fixation, and sensory signals expected to arrive in response to each shift of attention. In the modern view of the problem, invariant object recognition is provided by the following: (1) separated processing of `what' (object features) and `where' (spatial features) information at high levels of the visual system; (2) mechanisms of visual attention using `where' information; (3) representation of `what' information in an object-based frame of reference (OFR). However, most recent models of vision based on OFR have demonstrated the ability of invariant recognition of only simple objects like letters or binary objects without background, i.e. objects to which a frame of reference is easily attached. In contrast, we use not OFR, but a feature-based frame of reference (FFR), connected with the basic feature (edge) at the fixation point. This has provided for our model, the ability for invariant representation of complex objects in gray-level images, but demands realization of behavioral aspects of vision described above. The developed model contains a neural network subsystem of low-level vision which extracts a set of primary features (edges) in each fixation, and high- level subsystem consisting of `what' (Sensory Memory) and `where' (Motor Memory) modules. The resolution of primary features extraction decreases with distances from the point of fixation. FFR provides both the invariant representation of object features in Sensor Memory and shifts of attention in Motor Memory. Object recognition consists in successive recall (from Motor Memory) and execution of shifts of attention and successive verification of the expected sets of features (stored in Sensory Memory). The model shows the ability of recognition of complex objects (such as faces) in gray-level images invariant with respect to shift, rotation, and scale.

  1. Exploring the patient perspective of fatigue in adults with visual impairment: a qualitative study

    PubMed Central

    Bode, Christina; van der Aa, Hilde P A; Hulshof, Carel T J; Bosmans, Judith E; van Rens, Gerardus H M B; van Nispen, Ruth M A

    2017-01-01

    Objectives Fatigue is an often mentioned symptom by patients with irreversible visual impairment. This study explored the patient perspective of fatigue in visually impaired adults with a focus on symptoms of fatigue, causes, consequences and coping strategies. Setting Two large Dutch low vision multidisciplinary rehabilitation organisations. Participants 16 visually impaired adults with severe symptoms of fatigue selected by purposive sampling. Methods A qualitative study involving semistructured interviews. A total of four first-level codes were top–down predetermined in correspondence with the topics of the research question. Verbatim transcribed interviews were analysed with a combination of a deductive and inductive approach using open and axial coding. Results Participants often described the symptoms of fatigue as a mental, daily and physical experience. The most often mentioned causes of fatigue were a high cognitive load, the intensity and amount of activities, the high effort necessary to establish visual perception, difficulty with light intensity and negative cognitions. Fatigue had the greatest impact on the ability to carry out social roles and participation, emotional functioning and cognitive functioning. The most common coping strategies were relaxation, external support, socialising and physical exercise and the acceptance of fatigue. Conclusions Our results indicate that low vision-related fatigue is mainly caused by population specific determinants that seem different from the fatigue experience described in studies with other patient populations. Fatigue may be central to the way patients react, adapt and compensate to the consequences of vision loss. These findings indicate a need for future research aimed at interventions specifically tailored to the unique aspects of fatigue related to vision loss. PMID:28775181

  2. A vision for modernizing environmental risk assessment

    EPA Science Inventory

    In 2007, the US National Research Council (NRC) published a Vision and Strategy for [human health] Toxicity Testing in the 21st century. Central to the vision was increased reliance on high throughput in vitro testing and predictive approaches based on mechanistic understanding o...

  3. Developing Administrative Vision.

    ERIC Educational Resources Information Center

    Chance, Edward W.

    Visionary leadership has emerged as a significant characteristic of high performing school administrators. Vision provides a sense of direction for the school and facilitates accomplishment. Administrators must move from authoritarian and managerial modes of operation to proactive leadership, and maintain a focus on the vision through turmoil and…

  4. Telemedicine and Diabetic Retinopathy: Review of Published Screening Programs

    PubMed Central

    Tozer, Kevin; Woodward, Maria A.; Newman-Casey, Paula A.

    2016-01-01

    Background Diabetic Retinopathy (DR) is a leading cause of blindness worldwide even though successful treatments exist. Improving screening and treatment could avoid many cases of vision loss. However, due to an increasing prevalence of diabetes, traditional in-person screening for DR for every diabetic patient is not feasible. Telemedicine is one viable solution to provide high-quality and efficient screening to large number of diabetic patients. Purpose To provide a narrative review of large DR telemedicine screening programs. Methods Articles were identified through a comprehensive search of the English-language literature published between 2000 and 2014. Telemedicine screening programs were included for review if they had published data on at least 150 patients and had available validation studies supporting their model. Screening programs were then categorized according to their American Telemedicine Association Validation Level. Results Seven programs from the US and abroad were identified and included in the review. Three programs were Category 1 programs (Ophdiat, EyePacs, and Digiscope), two were Category 2 programs (Eye Check, NHS Diabetic Eye Screening Program), and two were Category 3 programs (Joslin Vision Network, Alberta Screening Program). No program was identified that claimed category 4 status. Programs ranged from community or city level programs to large nationwide programs including millions of individuals. The programs demonstrated a high level of clinical accuracy in screening for DR. There was no consensus amongst the programs regarding the need for dilation, need for stereoscopic images, or the level of training for approved image graders. Conclusion Telemedicine programs have been clinically validated and successfully implemented across the globe. They can provide a high-level of clinical accuracy for screening for DR while improving patient access in a cost-effective and scalable manner. PMID:27430019

  5. The History in DNA: A Proposal to Generate a Change of Vision of Science in School

    ERIC Educational Resources Information Center

    Cortez, Leonardo A.; Latorre, Nubia P.; Hernández, Rubinsten

    2016-01-01

    Currently, in science teaching and in particular, natural science teaching there are concepts in the school that have a high level of abstraction. Concepts, such as atom, gene, mole and energy, among others are difficult to explain in an understanding manner to students. This situation requires the teacher to design alternative strategies to…

  6. Community-Based Violence Prevention: An Assessment of Pittsburgh's One Vision One Life Program. Monograph

    ERIC Educational Resources Information Center

    Wilson, Jeremy M.; Chermak, Steven; McGarrell, Edmund F.

    2010-01-01

    In 2006, more than 6 million individuals were victimized by violent crimes. Although violence is below levels of the early 1990s, it remains high. The extent of violence and its impact highlight a critical need to develop and implement effective programs to reduce violence and victimization. Communities have initiated a wide range of such…

  7. Associations of Extroversion and Parental Overprotection with Forming Relationships with Peers among Adolescents with and without Visual Impairments

    ERIC Educational Resources Information Center

    Pinquart, Martin; Pfeiffer, Jens P.

    2011-01-01

    This paper reports a study that focused on three risk factors that may be relevant for forming relationships with peers, namely, level of vision loss, low extroversion (high introversion), and parental overprotection. The authors analyzed the role of parental overprotection and extroversion in forming relationships with peers among 158 adolescents…

  8. Review of Efforts to Develop a Low-Luminance-Level Disability Glare Tester

    DTIC Science & Technology

    2009-09-01

    figures 1. LASIK and PRK refractive surgery. .......................................................................................... 6  2...inadequate at this time, particularly for post refractive surgery patients. Early LASIK and PRK produced a very high incidence of night vision...1999). They found that before PRK or LASER in-situ keratomileusis ( LASIK ), simulated pupil dilation from 3 to 7 mm caused a 5-6 fold increase in

  9. 2013 Progress Report -- DOE Joint Genome Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-11-01

    In October 2012, we introduced a 10-Year Strategic Vision [http://bit.ly/JGI-Vision] for the Institute. A central focus of this Strategic Vision is to bridge the gap between sequenced genomes and an understanding of biological functions at the organism and ecosystem level. This involves the continued massive-scale generation of sequence data, complemented by orthogonal new capabilities to functionally annotate these large sequence data sets. Our Strategic Vision lays out a path to guide our decisions and ensure that the evolving set of experimental and computational capabilities available to DOE JGI users will continue to enable groundbreaking science.

  10. Knowledge-based vision and simple visual machines.

    PubMed Central

    Cliff, D; Noble, J

    1997-01-01

    The vast majority of work in machine vision emphasizes the representation of perceived objects and events: it is these internal representations that incorporate the 'knowledge' in knowledge-based vision or form the 'models' in model-based vision. In this paper, we discuss simple machine vision systems developed by artificial evolution rather than traditional engineering design techniques, and note that the task of identifying internal representations within such systems is made difficult by the lack of an operational definition of representation at the causal mechanistic level. Consequently, we question the nature and indeed the existence of representations posited to be used within natural vision systems (i.e. animals). We conclude that representations argued for on a priori grounds by external observers of a particular vision system may well be illusory, and are at best place-holders for yet-to-be-identified causal mechanistic interactions. That is, applying the knowledge-based vision approach in the understanding of evolved systems (machines or animals) may well lead to theories and models that are internally consistent, computationally plausible, and entirely wrong. PMID:9304684

  11. Rapid and highly resolving associative affective learning: convergent electro- and magnetoencephalographic evidence from vision and audition.

    PubMed

    Steinberg, Christian; Bröckelmann, Ann-Kathrin; Rehbein, Maimu; Dobel, Christian; Junghöfer, Markus

    2013-03-01

    Various pathway models for emotional processing suggest early prefrontal contributions to affective stimulus evaluation. Yet, electrophysiological evidence for such rapid modulations is still sparse. In a series of four MEG/EEG studies which investigated associative learning in vision and audition using a novel MultiCS Conditioning paradigm, many different neutral stimuli (faces, tones) were paired with aversive and appetitive events in only two to three learning instances. Electrophysiological correlates of neural activity revealed highly significant amplified processing for conditioned stimuli within distributed prefrontal and sensory cortical networks. In both, vision and audition, affect-specific responses occurred in two successive waves of rapid (vision: 50-80 ms, audition: 25-65 ms) and mid-latency (vision: >130 ms, audition: >100 ms) processing. Interestingly, behavioral measures indicated that MultiCS Conditioning successfully prevented contingency awareness. We conclude that affective processing rapidly recruits highly elaborate and widely distributed networks with substantial capacity for fast learning and excellent resolving power. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Role of optometry school in single day large scale school vision testing

    PubMed Central

    Anuradha, N; Ramani, Krishnakumar

    2015-01-01

    Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271

  13. Role of high-order aberrations in senescent changes in spatial vision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliot, S; Choi, S S; Doble, N

    2009-01-06

    The contributions of optical and neural factors to age-related losses in spatial vision are not fully understood. We used closed-loop adaptive optics to test the visual benefit of correcting monochromatic high-order aberrations (HOAs) on spatial vision for observers ranging in age from 18-81 years. Contrast sensitivity was measured monocularly using a two-alternative forced choice (2AFC) procedure for sinusoidal gratings over 6 mm and 3 mm pupil diameters. Visual acuity was measured using a spatial 4AFC procedure. Over a 6 mm pupil, young observers showed a large benefit of AO at high spatial frequencies, whereas older observers exhibited the greatest benefitmore » at middle spatial frequencies, plus a significantly larger increase in visual acuity. When age-related miosis is controlled, young and old observers exhibited a similar benefit of AO for spatial vision. An increase in HOAs cannot account for the complete senescent decline in spatial vision. These results may indicate a larger role of additional optical factors when the impact of HOAs is removed, but also lend support for the importance of neural factors in age-related changes in spatial vision.« less

  14. Factors influencing hand/eye synchronicity in the computer age.

    PubMed

    Grant, A H

    1992-09-01

    In using a computer, the relation of vision to hand/finger actuated keyboard usage in performing fine motor-coordinated functions is influenced by the physical location, size, and collective placement of the keys. Traditional nonprehensile flat/rectangular keyboard applications usually require a high and nearly constant level of visual attention. Biometrically shaped keyboards would allow for prehensile hand-posturing, thus affording better tactile familiarity with the keys, requiring less intense and less constant level of visual attention to the task, and providing a greater measure of freedom from having to visualize the key(s). Workpace and related physiological changes, aging, onset of monocularization (intermittent lapsing of binocularity for near vision) that accompanies presbyopia, tool colors, and background contrast are factors affecting constancy of visual attention to task performance. Capitas extension, excessive excyclotorsion, and repetitive strain injuries (such as carpal tunnel syndrome) are common and debilitating concomitants to computer usage. These problems can be remedied by improved keyboard design. The salutary role of mnemonics in minimizing visual dependency is discussed.

  15. Illumination-based synchronization of high-speed vision sensors.

    PubMed

    Hou, Lei; Kagami, Shingo; Hashimoto, Koichi

    2010-01-01

    To acquire images of dynamic scenes from multiple points of view simultaneously, the acquisition time of vision sensors should be synchronized. This paper describes an illumination-based synchronization method derived from the phase-locked loop (PLL) algorithm. Incident light to a vision sensor from an intensity-modulated illumination source serves as the reference signal for synchronization. Analog and digital computation within the vision sensor forms a PLL to regulate the output signal, which corresponds to the vision frame timing, to be synchronized with the reference. Simulated and experimental results show that a 1,000 Hz frame rate vision sensor was successfully synchronized with 32 μs jitters.

  16. Synthetic Vision Systems - Operational Considerations Simulation Experiment

    NASA Technical Reports Server (NTRS)

    Kramer, Lynda J.; Williams, Steven P.; Bailey, Randall E.; Glaab, Louis J.

    2007-01-01

    Synthetic vision is a computer-generated image of the external scene topography that is generated from aircraft attitude, high-precision navigation information, and data of the terrain, obstacles, cultural features, and other required flight information. A synthetic vision system (SVS) enhances this basic functionality with real-time integrity to ensure the validity of the databases, perform obstacle detection and independent navigation accuracy verification, and provide traffic surveillance. Over the last five years, NASA and its industry partners have developed and deployed SVS technologies for commercial, business, and general aviation aircraft which have been shown to provide significant improvements in terrain awareness and reductions in the potential for Controlled-Flight-Into-Terrain incidents/accidents compared to current generation cockpit technologies. It has been hypothesized that SVS displays can greatly improve the safety and operational flexibility of flight in Instrument Meteorological Conditions (IMC) to a level comparable to clear-day Visual Meteorological Conditions (VMC), regardless of actual weather conditions or time of day. An experiment was conducted to evaluate SVS and SVS-related technologies as well as the influence of where the information is provided to the pilot (e.g., on a Head-Up or Head-Down Display) for consideration in defining landing minima based upon aircraft and airport equipage. The "operational considerations" evaluated under this effort included reduced visibility, decision altitudes, and airport equipage requirements, such as approach lighting systems, for SVS-equipped aircraft. Subjective results from the present study suggest that synthetic vision imagery on both head-up and head-down displays may offer benefits in situation awareness; workload; and approach and landing performance in the visibility levels, approach lighting systems, and decision altitudes tested.

  17. Synthetic vision systems: operational considerations simulation experiment

    NASA Astrophysics Data System (ADS)

    Kramer, Lynda J.; Williams, Steven P.; Bailey, Randall E.; Glaab, Louis J.

    2007-04-01

    Synthetic vision is a computer-generated image of the external scene topography that is generated from aircraft attitude, high-precision navigation information, and data of the terrain, obstacles, cultural features, and other required flight information. A synthetic vision system (SVS) enhances this basic functionality with real-time integrity to ensure the validity of the databases, perform obstacle detection and independent navigation accuracy verification, and provide traffic surveillance. Over the last five years, NASA and its industry partners have developed and deployed SVS technologies for commercial, business, and general aviation aircraft which have been shown to provide significant improvements in terrain awareness and reductions in the potential for Controlled-Flight-Into-Terrain incidents / accidents compared to current generation cockpit technologies. It has been hypothesized that SVS displays can greatly improve the safety and operational flexibility of flight in Instrument Meteorological Conditions (IMC) to a level comparable to clear-day Visual Meteorological Conditions (VMC), regardless of actual weather conditions or time of day. An experiment was conducted to evaluate SVS and SVS-related technologies as well as the influence of where the information is provided to the pilot (e.g., on a Head-Up or Head-Down Display) for consideration in defining landing minima based upon aircraft and airport equipage. The "operational considerations" evaluated under this effort included reduced visibility, decision altitudes, and airport equipage requirements, such as approach lighting systems, for SVS-equipped aircraft. Subjective results from the present study suggest that synthetic vision imagery on both head-up and head-down displays may offer benefits in situation awareness; workload; and approach and landing performance in the visibility levels, approach lighting systems, and decision altitudes tested.

  18. A conceptual model for vision rehabilitation

    PubMed Central

    Roberts, Pamela S.; Rizzo, John-Ross; Hreha, Kimberly; Wertheimer, Jeffrey; Kaldenberg, Jennifer; Hironaka, Dawn; Riggs, Richard; Colenbrander, August

    2017-01-01

    Vision impairments are highly prevalent after acquired brain injury (ABI). Conceptual models that focus on constructing intellectual frameworks greatly facilitate comprehension and implementation of practice guidelines in an interprofessional setting. The purpose of this article is to provide a review of the vision literature in ABI, describe a conceptual model for vision rehabilitation, explain its potential clinical inferences, and discuss its translation into rehabilitation across multiple practice settings and disciplines. PMID:27997671

  19. A conceptual model for vision rehabilitation.

    PubMed

    Roberts, Pamela S; Rizzo, John-Ross; Hreha, Kimberly; Wertheimer, Jeffrey; Kaldenberg, Jennifer; Hironaka, Dawn; Riggs, Richard; Colenbrander, August

    2016-01-01

    Vision impairments are highly prevalent after acquired brain injury (ABI). Conceptual models that focus on constructing intellectual frameworks greatly facilitate comprehension and implementation of practice guidelines in an interprofessional setting. The purpose of this article is to provide a review of the vision literature in ABI, describe a conceptual model for vision rehabilitation, explain its potential clinical inferences, and discuss its translation into rehabilitation across multiple practice settings and disciplines.

  20. Criteria for a State-of-the-Art Vision Test System

    DTIC Science & Technology

    1985-05-01

    tests are enumerated for possible inclusion in a battery of candidate vision tests to be statistically examined for validity as predictors of aircrew...derived subset thereof) of vision tests may be given to a series of individuals, and statistical tests may be used to determine which visual functions...no target. Statistical analysis of the responses would set a threshold level, which would define the smallest size - (most distant target) or least

  1. Integrity Determination for Image Rendering Vision Navigation

    DTIC Science & Technology

    2016-03-01

    identifying an object within a scene, tracking a SIFT feature between frames or matching images and/or features for stereo vision applications. This... object level, either in 2-D or 3-D, versus individual features. There is a breadth of information, largely from the machine vision community...matching or image rendering image correspondence approach is based upon using either 2-D or 3-D object models or templates to perform object detection or

  2. Effect of intensive insulin therapy on macular biometrics, plasma VEGF and its soluble receptor in newly diagnosed diabetic patients.

    PubMed

    Hernández, Cristina; Zapata, Miguel A; Losada, Eladio; Villarroel, Marta; García-Ramírez, Marta; García-Arumí, José; Simó, Rafael

    2010-07-01

    To evaluate whether intensive insulin therapy leads to changes in macular biometrics (volume and thickness) in newly diagnosed diabetic patients with acute hyperglycaemia and its relationship with serum levels of vascular endothelial growth factor (VEGF) and its soluble receptor (sFlt-1). Twenty-six newly diagnosed diabetic patients admitted to our hospital to initiate intensive insulin treatment were prospectively recruited. Examinations were performed on admission (day 1) and during follow-up (days 3, 10 and 21) and included a questionnaire regarding the presence of blurred vision, standardized refraction measurements and optical coherence tomography. Plasma VEGF and sFlt-1 were assessed by ELISA at baseline and during follow-up. At study entry seven patients (26.9%) complained of blurred vision and five (19.2%) developed burred vision during follow-up. Macular volume and thickness increased significantly (p = 0.008 and p = 0.04, respectively) in the group with blurred vision at day 3 and returned to the baseline value at 10 days. This pattern was present in 18 out of the 24 eyes from patients with blurred vision. By contrast, macular biometrics remained unchanged in the group without blurred vision. We did not detect any significant changes in VEGF levels during follow-up. By contrast, a significant reduction of sFlt-1 was observed in those patients with blurred vision at day 3 (p = 0.03) with normalization by day 10. Diabetic patients with blurred vision after starting insulin therapy present a significant transient increase in macular biometrics which is associated with a decrease in circulating sFlt-1. Copyright (c) 2010 John Wiley & Sons, Ltd.

  3. [The Performance Analysis for Lighting Sources in Highway Tunnel Based on Visual Function].

    PubMed

    Yang, Yong; Han, Wen-yuan; Yan, Ming; Jiang, Hai-feng; Zhu, Li-wei

    2015-10-01

    Under the condition of mesopic vision, the spectral luminous efficiency function is shown as a series of curves. Its peak wavelength and intensity are affected by light spectrum, background brightness and other aspects. The impact of light source to lighting visibility could not be carried out via a single optical parametric characterization. The reaction time of visual cognition is regard as evaluating indexes in this experiment. Under the condition of different speed and luminous environment, testing visual cognition based on vision function method. The light sources include high pressure sodium, electrodeless fluorescent lamp and white LED with three kinds of color temperature (the range of color temperature is from 1 958 to 5 537 K). The background brightness value is used for basic section of highway tunnel illumination and general outdoor illumination, its range is between 1 and 5 cd x m(-)2. All values are in the scope of mesopic vision. Test results show that: under the same condition of speed and luminance, the reaction time of visual cognition that corresponding to high color temperature of light source is shorter than it corresponding to low color temperature; the reaction time corresponding to visual target in high speed is shorter than it in low speed. At the end moment, however, the visual angle of target in observer's visual field that corresponding to low speed was larger than it corresponding to high speed. Based on MOVE model, calculating the equivalent luminance of human mesopic vision, which is on condition of different emission spectrum and background brightness that formed by test lighting sources. Compared with photopic vision result, the standard deviation (CV) of time-reaction curve corresponding to equivalent brightness of mesopic vision is smaller. Under the condition of mesopic vision, the discrepancy between equivalent brightness of different lighting source and photopic vision, that is one of the main reasons for causing the discrepancy of visual recognition. The emission spectrum peak of GaN chip is approximate to the wave length peak of efficiency function in photopic vision. The lighting visual effect of write LED in high color temperature is better than it in low color temperature and electrodeless fluorescent lamp. The lighting visual effect of high pressure sodium is weak. Because of its peak value is around the Na+ characteristic spectra.

  4. Step 1: Human System Interface (HSI) Functional Requirements Document (FRD). Version 2

    NASA Technical Reports Server (NTRS)

    2006-01-01

    This Functional Requirements Document (FRD) establishes a minimum set of Human System Interface (HSI) functional requirements to achieve the Access 5 Vision of "operating High Altitude, Long Endurance (HALE) Unmanned Aircraft Systems (UAS) routinely, safely, and reliably in the National Airspace System (NAS)". Basically, it provides what functions are necessary to fly UAS in the NAS. The framework used to identify the appropriate functions was the "Aviate, Navigate, Communicate, and Avoid Hazards" structure identified in the Access 5 FRD. As a result, fifteen high-level functional requirements were developed. In addition, several of them have been decomposed into low-level functional requirements to provide more detail.

  5. Prevalence of vision loss among hospital in-patients; a risk factor for falls?

    PubMed

    Leat, Susan J; Zecevic, Aleksandra A; Keeling, Alexis; Hileeto, Denise; Labreche, Tammy; Brymer, Christopher

    2018-01-01

    Despite poor vision being a risk factor for falls, current hospital policies and practices often do not include a vision assessment at patient admission or in the hospital's incident reporting system when a fall occurs. Our purpose was to document the prevalence of vision loss in hospital general medicine units to increase awareness of poor vision as a potential risk factor for falls that occur within the hospital, and inform future preventative practice. This cross-sectional study took place in medicine units of an acute care hospital. Participants were adult in-patients. Visual acuity (VA), contrast sensitivity and stereoacuity were measured, and patients were screened for field loss, extinction and neglect. 115 participants took part (average age 67 ± 17, 48% female). Overall, 89% had a visual impairment defined as being outside the age-norms for one or more vision measure, 62% had low vision, and 36% had vision loss equivalent to legal blindness [VA equal to or poorer than 1.0 logMAR (6/60, 20/200) or ≥10x below age-norms]. There was a considerable discrepancy between the prevalence of low vision and the percentage of patients who reported an ocular diagnosis that would result in visual loss (30%). Ten patients fell during the study period, and of these 100% had visual impairment, 90% had low vision and 60% had vision loss equivalent to legal blindness, which compares to 58%, 22% and 9% for non-fallers. Similar high prevalences were found in those whose reason for admission to the hospital was a fall (92%, 63% and 33% respectively). Vision loss has a high prevalence among patients in hospital medicine units, and is higher still among those who fall. Since vision loss may be a contributing factor to falls that occur in hospitals, implementing an assessment of vision at hospital admission would be useful to alert staff to those patients who are at risk for falls due to poor vision, so that preventative measures can be applied. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  6. Image/video understanding systems based on network-symbolic models

    NASA Astrophysics Data System (ADS)

    Kuvich, Gary

    2004-03-01

    Vision is a part of a larger information system that converts visual information into knowledge structures. These structures drive vision process, resolve ambiguity and uncertainty via feedback projections, and provide image understanding that is an interpretation of visual information in terms of such knowledge models. Computer simulation models are built on the basis of graphs/networks. The ability of human brain to emulate similar graph/network models is found. Symbols, predicates and grammars naturally emerge in such networks, and logic is simply a way of restructuring such models. Brain analyzes an image as a graph-type relational structure created via multilevel hierarchical compression of visual information. Primary areas provide active fusion of image features on a spatial grid-like structure, where nodes are cortical columns. Spatial logic and topology naturally present in such structures. Mid-level vision processes like perceptual grouping, separation of figure from ground, are special kinds of network transformations. They convert primary image structure into the set of more abstract ones, which represent objects and visual scene, making them easy for analysis by higher-level knowledge structures. Higher-level vision phenomena are results of such analysis. Composition of network-symbolic models combines learning, classification, and analogy together with higher-level model-based reasoning into a single framework, and it works similar to frames and agents. Computational intelligence methods transform images into model-based knowledge representation. Based on such principles, an Image/Video Understanding system can convert images into the knowledge models, and resolve uncertainty and ambiguity. This allows creating intelligent computer vision systems for design and manufacturing.

  7. Unmet refractive need and its determinants in Shahroud, Iran.

    PubMed

    Emamian, Mohammad Hassan; Zeraati, Hojjat; Majdzadeh, Reza; Shariati, Mohammad; Hashemi, Hassan; Fotouhi, Akbar

    2012-08-01

    Uncorrected refractive error plays a significant role in poor vision and blindness, and its correction is the most cost-effective intervention in eye care. In this study, we report the status of the unmet refractive need and the role of economic inequality in determining the level of this need in Shahroud, Iran. This cross-sectional nested case-control study was performed on 5,190 individuals aged 40-64 years. Cases and controls were individuals with uncorrected visual acuity worse than 0.3 LogMAR in the better eye who showed at least 0.2 LogMAR improvement after correction. Cases were individuals whose presenting vision was worse than 0.3 in the better eye but improved by at least 0.2 LogMAR after correction. Controls were individuals in whom the difference between the presenting and corrected vision was less than 0.2 LogMAR. The prevalence of the unmet need was 5.7 % and it was more prevalent in women (6.5 %) than in men (4.6 %) (p = 0.003). There was a gap of 19.6 % between the two groups of high and low economic status. The Oaxaca-Blinder decomposition method revealed that differences in the education level of the two groups accounted for half of this gap. Spectacle usage is better in Iran than in some other developing countries; however, in this study, about 40 % of those who required spectacles did not have them.

  8. Multiscale Enaction Model (MEM): the case of complexity and “context-sensitivity” in vision

    PubMed Central

    Laurent, Éric

    2014-01-01

    I review the data on human visual perception that reveal the critical role played by non-visual contextual factors influencing visual activity. The global perspective that progressively emerges reveals that vision is sensitive to multiple couplings with other systems whose nature and levels of abstraction in science are highly variable. Contrary to some views where vision is immersed in modular hard-wired modules, rather independent from higher-level or other non-cognitive processes, converging data gathered in this article suggest that visual perception can be theorized in the larger context of biological, physical, and social systems with which it is coupled, and through which it is enacted. Therefore, any attempt to model complexity and multiscale couplings, or to develop a complex synthesis in the fields of mind, brain, and behavior, shall involve a systematic empirical study of both connectedness between systems or subsystems, and the embodied, multiscale and flexible teleology of subsystems. The conceptual model (Multiscale Enaction Model [MEM]) that is introduced in this paper finally relates empirical evidence gathered from psychology to biocomputational data concerning the human brain. Both psychological and biocomputational descriptions of MEM are proposed in order to help fill in the gap between scales of scientific analysis and to provide an account for both the autopoiesis-driven search for information, and emerging perception. PMID:25566115

  9. A Vision of the 21st Century

    ERIC Educational Resources Information Center

    Bottoms, Gene

    2006-01-01

    The new vision for the 21st century is reflected in ACTE's recent position paper on strengthening the American high school through career and technical education. Teachers and administrators are encouraged to continue raising students' academic achievements and their high school completion rates. However, the way the American high school is…

  10. Body sway adaptation to addition but not withdrawal of stabilizing visual information is delayed by a concurrent cognitive task.

    PubMed

    Honeine, Jean-Louis; Crisafulli, Oscar; Schieppati, Marco

    2017-02-01

    The aim of this study was to test the effects of a concurrent cognitive task on the promptness of the sensorimotor integration and reweighting processes following addition and withdrawal of vision. Fourteen subjects stood in tandem while vision was passively added and removed. Subjects performed a cognitive task, consisting of counting backward in steps of three, or were "mentally idle." We estimated the time intervals following addition and withdrawal of vision at which body sway began to change. We also estimated the time constant of the exponential change in body oscillation until the new level of sway was reached, consistent with the current visual state. Under the mentally idle condition, mean latency was 0.67 and 0.46 s and the mean time constant was 1.27 and 0.59 s for vision addition and withdrawal, respectively. Following addition of vision, counting backward delayed the latency by about 300 ms, without affecting the time constant. Following withdrawal, counting backward had no significant effect on either latency or time constant. The extension by counting backward of the time interval to stabilization onset on addition of vision suggests a competition for allocation of cortical resources. Conversely, the absence of cognitive task effect on the rapid onset of destabilization on vision withdrawal, and on the relevant reweighting time course, advocates the intervention of a subcortical process. Diverting attention from a challenging standing task discloses a cortical supervision on the process of sensorimotor integration of new balance-stabilizing information. A subcortical process would instead organize the response to removal of the stabilizing sensory input. NEW & NOTEWORTHY This study is the first to test the effect of an arithmetic task on the time course of balance readjustment following visual withdrawal or addition. Performing such a cognitive task increases the time delay following addition of vision but has no effect on withdrawal dynamics. This suggests that sensorimotor integration following addition of a stabilizing signal is performed at a cortical level, whereas the response to its withdrawal is "automatic" and accomplished at a subcortical level. Copyright © 2017 the American Physiological Society.

  11. Investigation into the use of smartphone as a machine vision device for engineering metrology and flaw detection, with focus on drilling

    NASA Astrophysics Data System (ADS)

    Razdan, Vikram; Bateman, Richard

    2015-05-01

    This study investigates the use of a Smartphone and its camera vision capabilities in Engineering metrology and flaw detection, with a view to develop a low cost alternative to Machine vision systems which are out of range for small scale manufacturers. A Smartphone has to provide a similar level of accuracy as Machine Vision devices like Smart cameras. The objective set out was to develop an App on an Android Smartphone, incorporating advanced Computer vision algorithms written in java code. The App could then be used for recording measurements of Twist Drill bits and hole geometry, and analysing the results for accuracy. A detailed literature review was carried out for in-depth study of Machine vision systems and their capabilities, including a comparison between the HTC One X Android Smartphone and the Teledyne Dalsa BOA Smart camera. A review of the existing metrology Apps in the market was also undertaken. In addition, the drilling operation was evaluated to establish key measurement parameters of a twist Drill bit, especially flank wear and diameter. The methodology covers software development of the Android App, including the use of image processing algorithms like Gaussian Blur, Sobel and Canny available from OpenCV software library, as well as designing and developing the experimental set-up for carrying out the measurements. The results obtained from the experimental set-up were analysed for geometry of Twist Drill bits and holes, including diametrical measurements and flaw detection. The results show that Smartphones like the HTC One X have the processing power and the camera capability to carry out metrological tasks, although dimensional accuracy achievable from the Smartphone App is below the level provided by Machine vision devices like Smart cameras. A Smartphone with mechanical attachments, capable of image processing and having a reasonable level of accuracy in dimensional measurement, has the potential to become a handy low-cost Machine vision system for small scale manufacturers, especially in field metrology and flaw detection.

  12. Use of a sensitive EnVision +-based detection system for Western blotting: avoidance of streptavidin binding to endogenous biotin and biotin-containing proteins in kidney and other tissues.

    PubMed

    Banks, Rosamonde E; Craven, Rachel A; Harnden, Patricia A; Selby, Peter J

    2003-04-01

    Western blotting remains a central technique in confirming identities of proteins, their quantitation and analysis of various isoforms. The biotin-avidin/streptavidin system is often used as an amplification step to increase sensitivity but in some tissues such as kidney, "nonspecific" interactions may be a problem due to high levels of endogenous biotin-containing proteins. The EnVision system, developed for immunohistochemical applications, relies on binding of a polymeric conjugate consisting of up to 100 peroxidase molecules and 20 secondary antibody molecules linked directly to an activated dextran backbone, to the primary antibody. This study demonstrates that it is also a viable and sensitive alternative detection system in Western blotting applications.

  13. Sunlight-readable display technology: a dual-use case study

    NASA Astrophysics Data System (ADS)

    Blanchard, Randall D.

    1996-05-01

    This paper describes our vision of sunlight readable color display requirements, an alternate technology that offers a high level of performance, and how we implemented it for the military avionics display market. This knowledge base and product development experience was then applied with a comparable level of performance to commercial applications. The successful dual use of this technology for these two diverse markets is presented. Details of the technical commonality and a comparison of the design and performance differences are presented. A basis for specifying the required level of performance for a sunlight readable full color display is discussed. With the objective of providing a high level of image brightness and high ambient light rejection, a display architecture using collimated light is used. The resulting designs of two military cockpit display products, with contrast ratios above 20:1 in sunlight are shown. The performance of a commercial display providing several thousand foot- Lamberts of image brightness is presented.

  14. Introduction to the issue regarding research regarding age related macular degeneration

    USDA-ARS?s Scientific Manuscript database

    Blindness is the second greatest fear among the elderly. Age-related macular degeneration (AMD) is the leading cause of vision loss among the elderly in most industrialized nations. AMD first compromises central high acuity vision. Subsequently, all vision may be lost. AMD is a progressive retinal d...

  15. Evaluation of a Portable Collision Warning Device for Patients With Peripheral Vision Loss in an Obstacle Course.

    PubMed

    Pundlik, Shrinivas; Tomasi, Matteo; Luo, Gang

    2015-04-01

    A pocket-sized collision warning device equipped with a video camera was developed to predict impending collisions based on time to collision rather than proximity. A study was conducted in a high-density obstacle course to evaluate the effect of the device on collision avoidance in people with peripheral field loss (PFL). The 41-meter-long loop-shaped obstacle course consisted of 46 stationary obstacles from floor to head level and oncoming pedestrians. Twenty-five patients with tunnel vision (n = 13) or hemianopia (n = 12) completed four consecutive loops with and without the device, while not using any other habitual mobility aid. Walking direction and device usage order were counterbalanced. Number of collisions and preferred percentage of walking speed (PPWS) were compared within subjects. Collisions were reduced significantly by approximately 37% (P < 0.001) with the device (floor-level obstacles were excluded because the device was not designed for them). No patient had more collisions when using the device. Although the PPWS were also reduced with the device from 52% to 49% (P = 0.053), this did not account for the lower number of collisions, as the changes in collisions and PPWS were not correlated (P = 0.516). The device may help patients with a wide range of PFL avoid collisions with high-level obstacles while barely affecting their walking speed.

  16. Educating the blind brain: a panorama of neural bases of vision and of training programs in organic neurovisual deficits

    PubMed Central

    Coubard, Olivier A.; Urbanski, Marika; Bourlon, Clémence; Gaumet, Marie

    2014-01-01

    Vision is a complex function, which is achieved by movements of the eyes to properly foveate targets at any location in 3D space and to continuously refresh neural information in the different visual pathways. The visual system involves five main routes originating in the retinas but varying in their destination within the brain: the occipital cortex, but also the superior colliculus (SC), the pretectum, the supra-chiasmatic nucleus, the nucleus of the optic tract and terminal dorsal, medial and lateral nuclei. Visual pathway architecture obeys systematization in sagittal and transversal planes so that visual information from left/right and upper/lower hemi-retinas, corresponding respectively to right/left and lower/upper visual fields, is processed ipsilaterally and ipsialtitudinally to hemi-retinas in left/right hemispheres and upper/lower fibers. Organic neurovisual deficits may occur at any level of this circuitry from the optic nerve to subcortical and cortical destinations, resulting in low or high-level visual deficits. In this didactic review article, we provide a panorama of the neural bases of eye movements and visual systems, and of related neurovisual deficits. Additionally, we briefly review the different schools of rehabilitation of organic neurovisual deficits, and show that whatever the emphasis is put on action or perception, benefits may be observed at both motor and perceptual levels. Given the extent of its neural bases in the brain, vision in its motor and perceptual aspects is also a useful tool to assess and modulate central nervous system (CNS) in general. PMID:25538575

  17. Achieving the Earth Science Enterprise Vision for the 21st Century: Platform Challenges

    NASA Technical Reports Server (NTRS)

    Lemmerman, Loren; Komar, George (Technical Monitor)

    2001-01-01

    The ESE observational architecture of the future vision is dramatically different from that of today. The vision suggests observations from multiple orbits, collaborating space assets, and even seamless integration of space and other assets. Observations from GEO or from Libration points rather than from LEO suggest spacecraft carrying instruments with large deployable apertures. Minimization of launch costs suggests that these large apertures have long life, be extremely mass and volume efficient, and have low life cycle cost. Another significant challenge associated with high latitude orbits is high precision pointing and control. Finally, networks of spacecraft flying in predetermined constellation will be required either to apply complementary assets to an observation or to extend the virtual aperture beyond that attainable with a single spacecraft. These changes dictate development of new technology on several fronts, which are outlined in this paper. A section on high speed communications will outline requirements and approaches now envisioned. Sensorwebs will be developed from the viewpoint of work already begun for both space and for terrestrial networks. Precision guidance, navigation and control will be addressed from the perspective of precision flying for repeat pass interferometry and extreme pointing stability for advanced altimetry. A separate section will address requirements for distributed systems. Large lightweight deployables will be discussed with an emphasis on inflatable technology and its predicted benefits for large aperture instruments. For each technology area listed, current state-of-the-art, technological approaches for future development, and projected levels of performance are outlined.

  18. Action Recognition in a Crowded Environment

    PubMed Central

    Nieuwenhuis, Judith; Bülthoff, Isabelle; Barraclough, Nick; de la Rosa, Stephan

    2017-01-01

    So far, action recognition has been mainly examined with small point-light human stimuli presented alone within a narrow central area of the observer’s visual field. Yet, we need to recognize the actions of life-size humans viewed alone or surrounded by bystanders, whether they are seen in central or peripheral vision. Here, we examined the mechanisms in central vision and far periphery (40° eccentricity) involved in the recognition of the actions of a life-size actor (target) and their sensitivity to the presence of a crowd surrounding the target. In Experiment 1, we used an action adaptation paradigm to probe whether static or idly moving crowds might interfere with the recognition of a target’s action (hug or clap). We found that this type of crowds whose movements were dissimilar to the target action hardly affected action recognition in central and peripheral vision. In Experiment 2, we examined whether crowd actions that were more similar to the target actions affected action recognition. Indeed, the presence of that crowd diminished adaptation aftereffects in central vision as wells as in the periphery. We replicated Experiment 2 using a recognition task instead of an adaptation paradigm. With this task, we found evidence of decreased action recognition accuracy, but this was significant in peripheral vision only. Our results suggest that the presence of a crowd carrying out actions similar to that of the target affects its recognition. We outline how these results can be understood in terms of high-level crowding effects that operate on action-sensitive perceptual channels. PMID:29308177

  19. Organizational Cultural Factors Hindering Women Ascending to Top Management Positions in Public Universities in Kenya: A Case of Moi University

    ERIC Educational Resources Information Center

    Makori, Rebecca S.; Onyango, Maria; Attyang, Judith Miguda; Bantu, Edward; Onderi, Peter Omae

    2016-01-01

    It is observed that the major setback to economic development in Kenya is stagnation in industrial development. To overcome these, Kenya plans to be a middle level income nation by the year 2030. These plans are to be realized through "Vision 2030." To achieve these goals, Kenya requires gender mainstreamed team of highly skilled workers…

  20. Automatic rule generation for high-level vision

    NASA Technical Reports Server (NTRS)

    Rhee, Frank Chung-Hoon; Krishnapuram, Raghu

    1992-01-01

    A new fuzzy set based technique that was developed for decision making is discussed. It is a method to generate fuzzy decision rules automatically for image analysis. This paper proposes a method to generate rule-based approaches to solve problems such as autonomous navigation and image understanding automatically from training data. The proposed method is also capable of filtering out irrelevant features and criteria from the rules.

  1. Approaches to a cortical vision prosthesis: implications of electrode size and placement

    NASA Astrophysics Data System (ADS)

    Christie, Breanne P.; Ashmont, Kari R.; House, Paul A.; Greger, Bradley

    2016-04-01

    Objective. In order to move forward with the development of a cortical vision prosthesis, the critical issues in the field must be identified. Approach. To begin this process, we performed a brief review of several different cortical and retinal stimulation techniques that can be used to restore vision. Main results. Intracortical microelectrodes and epicortical macroelectrodes have been evaluated as the basis of a vision prosthesis. We concluded that an important knowledge gap necessitates an experimental in vivo performance evaluation of microelectrodes placed on the surface of the visual cortex. A comparison of the level of vision restored by intracortical versus epicortical microstimulation is necessary. Because foveal representation in the primary visual cortex involves more cortical columns per degree of visual field than does peripheral vision, restoration of foveal vision may require a large number of closely spaced microelectrodes. Based on previous studies of epicortical macrostimulation, it is possible that stimulation via surface microelectrodes could produce a lower spatial resolution, making them better suited for restoring peripheral vision. Significance. The validation of epicortical microstimulation in addition to the comparison of epicortical and intracortical approaches for vision restoration will fill an important knowledge gap and may have important implications for surgical strategies and device longevity. It is possible that the best approach to vision restoration will utilize both epicortical and intracortical microstimulation approaches, applying them appropriately to different visual representations in the primary visual cortex.

  2. Altered vision destabilizes gait in older persons.

    PubMed

    Helbostad, Jorunn L; Vereijken, Beatrix; Hesseberg, Karin; Sletvold, Olav

    2009-08-01

    This study assessed the effects of dim light and four experimentally induced changes in vision on gait speed and footfall and trunk parameters in older persons walking on level ground. Using a quasi-experimental design, gait characteristics were assessed in full light, dim light, and in dim light combined with manipulations resulting in reduced depth vision, double vision, blurred vision, and tunnel vision, respectively. A convenience sample of 24 home-dwelling older women and men (mean age 78.5 years, SD 3.4) with normal vision for their age and able to walk at least 10 m without assistance participated. Outcome measures were gait speed and spatial and temporal parameters of footfall and trunk acceleration, derived from an electronic gait mat and accelerometers. Dim light alone had no effect. Vision manipulations combined with dim light had effect on most footfall parameters but few trunk parameters. The largest effects were found regarding double and tunnel vision. Men increased and women decreased gait speed following manipulations (p=0.017), with gender differences also in stride velocity variability (p=0.017) and inter-stride medio-lateral trunk acceleration variability (p=0.014). Gender effects were related to differences in body height and physical functioning. Results indicate that visual problems lead to a more cautious and unstable gait pattern even under relatively simple conditions. This points to the importance of assessing vision in older persons and correcting visual impairments where possible.

  3. Vision Sensors and Cameras

    NASA Astrophysics Data System (ADS)

    Hoefflinger, Bernd

    Silicon charge-coupled-device (CCD) imagers have been and are a specialty market ruled by a few companies for decades. Based on CMOS technologies, active-pixel sensors (APS) began to appear in 1990 at the 1 μm technology node. These pixels allow random access, global shutters, and they are compatible with focal-plane imaging systems combining sensing and first-level image processing. The progress towards smaller features and towards ultra-low leakage currents has provided reduced dark currents and μm-size pixels. All chips offer Mega-pixel resolution, and many have very high sensitivities equivalent to ASA 12.800. As a result, HDTV video cameras will become a commodity. Because charge-integration sensors suffer from a limited dynamic range, significant processing effort is spent on multiple exposure and piece-wise analog-digital conversion to reach ranges >10,000:1. The fundamental alternative is log-converting pixels with an eye-like response. This offers a range of almost a million to 1, constant contrast sensitivity and constant colors, important features in professional, technical and medical applications. 3D retino-morphic stacking of sensing and processing on top of each other is being revisited with sub-100 nm CMOS circuits and with TSV technology. With sensor outputs directly on top of neurons, neural focal-plane processing will regain momentum, and new levels of intelligent vision will be achieved. The industry push towards thinned wafers and TSV enables backside-illuminated and other pixels with a 100% fill-factor. 3D vision, which relies on stereo or on time-of-flight, high-speed circuitry, will also benefit from scaled-down CMOS technologies both because of their size as well as their higher speed.

  4. Visual Acuity’s Association with Levels of Leisure-Time Physical Activity Among Community-Dwelling Older Adults

    PubMed Central

    Swanson, Mark W; Bodner, Eric; Sawyer, Patricia; Allman, Richard

    2013-01-01

    Little is known about the affect of reduced vision on physical activity in older adults. This study evaluates the association of visual acuity level, self-reported vision and ocular disease conditions with leisure-time physical activity and calculated caloric expenditure. A cross sectional study of 911 subjects 65 yr and older from the University of Alabama at Birmingham Study of Aging (SOA) cohort was conducted evaluating the association of vision-related variables to weekly kilocalorie expenditure calculated from the 17-item Leisure Time Physical Activity Questionnaire. Ordinal logistic regression was used to evaluate possible associations controlling for potential confounders. In multivariate analyses, each lower step in visual acuity category below 20/50 was significantly associated with reduced odds of having a higher level of physical activity OR 0.81, 95% CI 0.67, 0.97. Reduced visual acuity appears to be independently associated with lower levels of physical activity among community-dwelling adults. PMID:21945888

  5. Functional preservation and variation in the cone opsin genes of nocturnal tarsiers

    PubMed Central

    Ong, Perry S.; Perry, George H.

    2017-01-01

    The short-wavelength sensitive (S-) opsin gene OPN1SW is pseudogenized in some nocturnal primates and retained in others, enabling dichromatic colour vision. Debate on the functional significance of this variation has focused on dark conditions, yet many nocturnal species initiate activity under dim (mesopic) light levels that can support colour vision. Tarsiers are nocturnal, twilight-active primates and exemplary visual predators; they also express different colour vision phenotypes, raising the possibility of discrete adaptations to mesopic conditions. To explore this premise, we conducted a field study in two stages. First, to estimate the level of functional constraint on colour vision, we sequenced OPN1SW in 12 wild-caught Philippine tarsiers (Tarsius syrichta). Second, to explore whether the dichromatic visual systems of Philippine and Bornean (Tarsius bancanus) tarsiers—which express alternate versions of the medium/long-wavelength sensitive (M/L-) opsin gene OPN1MW/OPN1LW—confer differential advantages specific to their respective habitats, we used twilight and moonlight conditions to model the visual contrasts of invertebrate prey. We detected a signature of purifying selection for OPN1SW, indicating that colour vision confers an adaptive advantage to tarsiers. However, this advantage extends to a relatively small proportion of prey–background contrasts, and mostly brown arthropod prey amid leaf litter. We also found that the colour vision of T. bancanus is advantageous for discriminating prey under twilight that is enriched in shorter (bluer) wavelengths, a plausible idiosyncrasy of understorey habitats in Borneo. This article is part of the themed issue ‘Vision in dim light’. PMID:28193820

  6. A Novel Event-Based Incipient Slip Detection Using Dynamic Active-Pixel Vision Sensor (DAVIS)

    PubMed Central

    Rigi, Amin

    2018-01-01

    In this paper, a novel approach to detect incipient slip based on the contact area between a transparent silicone medium and different objects using a neuromorphic event-based vision sensor (DAVIS) is proposed. Event-based algorithms are developed to detect incipient slip, slip, stress distribution and object vibration. Thirty-seven experiments were performed on five objects with different sizes, shapes, materials and weights to compare precision and response time of the proposed approach. The proposed approach is validated by using a high speed constitutional camera (1000 FPS). The results indicate that the sensor can detect incipient slippage with an average of 44.1 ms latency in unstructured environment for various objects. It is worth mentioning that the experiments were conducted in an uncontrolled experimental environment, therefore adding high noise levels that affected results significantly. However, eleven of the experiments had a detection latency below 10 ms which shows the capability of this method. The results are very promising and show a high potential of the sensor being used for manipulation applications especially in dynamic environments. PMID:29364190

  7. The significance of end-of-life dreams and visions.

    PubMed

    Grant, Pei; Wright, Scott; Depner, Rachel; Luczkiewicz, Debra

    End-of-life dreams and visions (ELDVs) have been well documented through history and across cultures. They appear to affect both dying people and their families deeply, and may be a source of profound meaning and comfort. The aims of the study were to; document hospice patients' ELDV experiences over time using a daily survey, examine the content and subjective significance of ELDVs, and relate the prevalence, content and significance of end-of-life experiences over time until death. Patients (n = 66) in a hospice inpatient unit, between January 2011 and July 2012, were interviewed daily. The interview contained closed questions about the content, frequency and level of comfort or distress of dreams and visions. Most participants reported at least one dream or vision and almost half of the dreams and visions occurred during sleep. Nearly all patients reported that their experience felt real. The most common content featured deceased friends and relatives, followed by living friends and relatives. As participants approached death, comforting dreams and visions of the deceased became more prevalent. End-of-life dreams and visions are commonly experienced during dying. These dreams and visions may be a profound source of potential meaning and comfort to the dying.

  8. Night myopia is reduced in binocular vision.

    PubMed

    Chirre, Emmanuel; Prieto, Pedro M; Schwarz, Christina; Artal, Pablo

    2016-06-01

    Night myopia, which is a shift in refraction with light level, has been widely studied but still lacks a complete understanding. We used a new infrared open-view binocular Hartmann-Shack wave front sensor to quantify night myopia under monocular and natural binocular viewing conditions. Both eyes' accommodative response, aberrations, pupil diameter, and convergence were simultaneously measured at light levels ranging from photopic to scotopic conditions to total darkness. For monocular vision, reducing the stimulus luminance resulted in a progression of the accommodative state that tends toward the subject's dark focus or tonic accommodation and a change in convergence following the induced accommodative error. Most subjects presented a myopic shift of accommodation that was mitigated in binocular vision. The impact of spherical aberration on the focus shift was relatively small. Our results in monocular conditions support the hypothesis that night myopia has an accommodative origin as the eye progressively changes its accommodation state with decreasing luminance toward its resting state in total darkness. On the other hand, binocularity restrains night myopia, possibly by using fusional convergence as an additional accommodative cue, thus reducing the potential impact of night myopia on vision at low light levels.

  9. Development and validation of an instrument to assess job satisfaction in eye-care personnel.

    PubMed

    Paudel, Prakash; Cronjé, Sonja; O'Connor, Patricia M; Khadka, Jyoti; Rao, Gullapalli N; Holden, Brien A

    2017-11-01

    The aim was to develop and validate an instrument to measure job satisfaction in eye-care personnel and assess the job satisfaction of one-year trained vision technicians in India. A pilot instrument for assessing job satisfaction was developed, based on a literature review and input from a public health expert panel. Rasch analysis was used to assess psychometric properties and to undertake an iterative item reduction. The instrument was then administered to vision technicians in vision centres of Andhra Pradesh in India. Associations between vision technicians' job satisfaction and factors such as age, gender and experience were analysed using t-test and one-way analysis of variance. Rasch analysis confirmed that the 15-item job satisfaction in eye-care personnel (JSEP) was a unidimensional instrument with good fit statistics, measurement precisions and absence of differential item functioning. Overall, vision technicians reported high rates of job satisfaction (0.46 logits). Age, gender and experience were not associated with high job satisfaction score. Item score analysis showed non-financial incentives, salary and workload were the most important determinants of job satisfaction. The 15-item JSEP instrument is a valid instrument for assessing job satisfaction among eye-care personnel. Overall, vision technicians in India demonstrated high rates of job satisfaction. © 2016 Optometry Australia.

  10. Forging Medical Public-Private Relationships in Support of Combatant Commander Objectives-Getting Past the Vision Statement

    DTIC Science & Technology

    2009-04-01

    non-governmental levels . The military planner faces a daunting question—in what missions are NGO partnerships appropriate? AU/ACSC/LaGrou/AY09 8...for a wide range of operations. As the illustration shows, partnerships at the cooperative level are more likely to exist (and succeed) in...Support of Combatant Commander Objectives—Getting Past the Vision Statement by Edward J. LaGrou, Major, USAF A Research Report

  11. Vision, Educational Level, and Empowering Work Relationships.

    ERIC Educational Resources Information Center

    Johnson, G. M.

    1995-01-01

    Thirty-one machinists (blind, sighted, and visually impaired) answered questions about trust, resource sharing, and empowerment in work relationships. Employees with low vision were the least trusting and trusted, received the fewest shared resources, and reported proportionately more disempowering relationships. More educated employees saw more…

  12. Coaching to vision versus coaching to improvement needs: a preliminary investigation on the differential impacts of fostering positive and negative emotion during real time executive coaching sessions

    PubMed Central

    Howard, Anita R.

    2015-01-01

    Drawing on intentional change theory (ICT; Boyatzis, 2006), this study examined the differential impact of inducing coaching recipients’ vision/positive emotion versus improvement needs/negative emotion during real time executive coaching sessions. A core aim of the study was to empirically test two central ICT propositions on the effects of using the coached person’s Positive Emotional Attractor (vision/PEA) versus Negative Emotional Attractor (improvement needs/NEA) as the anchoring framework of a onetime, one-on-one coaching session on appraisal of 360° feedback and discussion of possible change goals. Eighteen coaching recipients were randomly assigned to two coaching conditions, the coaching to vision/PEA condition and the coaching to improvement needs/NEA condition. Two main hypotheses were tested. Hypothesis1 predicted that participants in the vision/PEA condition would show higher levels of expressed positive emotion during appraisal of 360° feedback results and discussion of change goals than recipients in the improvement needs/NEA condition. Hypothesis2 predicted that vision/PEA participants would show lower levels of stress immediately after the coaching session than improvement needs/NEA participants. Findings showed that coaching to vision/the PEA fostered significantly lower levels of expressed negative emotion and anger during appraisal of 360° feedback results as compared to coaching to improvements needs/the NEA. Vision-focused coaching also fostered significantly greater exploration of personal passions and future desires, and more positive engagement during 360° feedback appraisal. No significant differences between the two conditions were found in emotional processing during discussion of change goals or levels of stress immediately after the coaching session. Current findings suggest that vision/PEA arousal versus improvement needs/NEA arousal impact the coaching process in quite different ways; that the coach’s initial framing of the session predominantly in the PEA (or, alternatively, predominantly in the NEA) fosters emotional processing that is driven by this initial framing; and that both the PEA (and associated positive emotions) and NEA (and associated negative emotions) play an important and recurrent role in shaping the change process. Further study on these outcomes will enable researchers to shed more light on the differential impact of the PEA versus NEA on intentional change, and how to leverage the benefits of both emotional attractors. Findings also suggest that coaches can benefit from better understanding the importance of tapping intrinsic motivation and personal passions through coaching to vision/the PEA. Coaches additionally may benefit from better understanding how to leverage the long-term advantages, and restorative benefits, of positive emotions during coaching engagements. The findings also highlight coaches’ need to appreciate the impact of timing effects on coaching intentional change, and how coaches can play a critical role in calibrating the pace and focus of work on intentional change. Early arousal of the coachee’s PEA, accompanied by recurrent PEA–NEA induction, may help coachees be/become more creative, optimistic, and resilient during a given change process. Overall, primary focus on vision/PEA and secondary focus on improvement needs/NEA may better equip coaches and coaching recipients to work together on building robust learning, development, and change. Keywords-133pt executive coaching, vision, improvement needs, positive emotion, negative emotion, emotional appraisal, intentional change, positive psychology PMID:25964768

  13. Coaching to vision versus coaching to improvement needs: a preliminary investigation on the differential impacts of fostering positive and negative emotion during real time executive coaching sessions.

    PubMed

    Howard, Anita R

    2015-01-01

    Drawing on intentional change theory (ICT; Boyatzis, 2006), this study examined the differential impact of inducing coaching recipients' vision/positive emotion versus improvement needs/negative emotion during real time executive coaching sessions. A core aim of the study was to empirically test two central ICT propositions on the effects of using the coached person's Positive Emotional Attractor (vision/PEA) versus Negative Emotional Attractor (improvement needs/NEA) as the anchoring framework of a onetime, one-on-one coaching session on appraisal of 360° feedback and discussion of possible change goals. Eighteen coaching recipients were randomly assigned to two coaching conditions, the coaching to vision/PEA condition and the coaching to improvement needs/NEA condition. Two main hypotheses were tested. Hypothesis1 predicted that participants in the vision/PEA condition would show higher levels of expressed positive emotion during appraisal of 360° feedback results and discussion of change goals than recipients in the improvement needs/NEA condition. Hypothesis2 predicted that vision/PEA participants would show lower levels of stress immediately after the coaching session than improvement needs/NEA participants. Findings showed that coaching to vision/the PEA fostered significantly lower levels of expressed negative emotion and anger during appraisal of 360° feedback results as compared to coaching to improvements needs/the NEA. Vision-focused coaching also fostered significantly greater exploration of personal passions and future desires, and more positive engagement during 360° feedback appraisal. No significant differences between the two conditions were found in emotional processing during discussion of change goals or levels of stress immediately after the coaching session. Current findings suggest that vision/PEA arousal versus improvement needs/NEA arousal impact the coaching process in quite different ways; that the coach's initial framing of the session predominantly in the PEA (or, alternatively, predominantly in the NEA) fosters emotional processing that is driven by this initial framing; and that both the PEA (and associated positive emotions) and NEA (and associated negative emotions) play an important and recurrent role in shaping the change process. Further study on these outcomes will enable researchers to shed more light on the differential impact of the PEA versus NEA on intentional change, and how to leverage the benefits of both emotional attractors. Findings also suggest that coaches can benefit from better understanding the importance of tapping intrinsic motivation and personal passions through coaching to vision/the PEA. Coaches additionally may benefit from better understanding how to leverage the long-term advantages, and restorative benefits, of positive emotions during coaching engagements. The findings also highlight coaches' need to appreciate the impact of timing effects on coaching intentional change, and how coaches can play a critical role in calibrating the pace and focus of work on intentional change. Early arousal of the coachee's PEA, accompanied by recurrent PEA-NEA induction, may help coachees be/become more creative, optimistic, and resilient during a given change process. Overall, primary focus on vision/PEA and secondary focus on improvement needs/NEA may better equip coaches and coaching recipients to work together on building robust learning, development, and change. Keywords-133pt executive coaching, vision, improvement needs, positive emotion, negative emotion, emotional appraisal, intentional change, positive psychology.

  14. Preparing Mathematics Teachers for Elementary High-Poverty Schools: Perceptions and Suggestions from Preservice Teachers

    ERIC Educational Resources Information Center

    McKinney, Sueanne E.; Berry, Robert Q., III; Jackson, Joan M.

    2007-01-01

    The National Council of Teachers of Mathematics articulates an ambitious vision of a high-quality mathematics program. Achieving this vision requires competent and knowledgeable teachers who can support all students in learning mathematics concepts with understanding. Effective mathematics teachers are especially needed for high-poverty schools…

  15. Cognitive vision system for control of dexterous prosthetic hands: Experimental evaluation

    PubMed Central

    2010-01-01

    Background Dexterous prosthetic hands that were developed recently, such as SmartHand and i-LIMB, are highly sophisticated; they have individually controllable fingers and the thumb that is able to abduct/adduct. This flexibility allows implementation of many different grasping strategies, but also requires new control algorithms that can exploit the many degrees of freedom available. The current study presents and tests the operation of a new control method for dexterous prosthetic hands. Methods The central component of the proposed method is an autonomous controller comprising a vision system with rule-based reasoning mounted on a dexterous hand (CyberHand). The controller, termed cognitive vision system (CVS), mimics biological control and generates commands for prehension. The CVS was integrated into a hierarchical control structure: 1) the user triggers the system and controls the orientation of the hand; 2) a high-level controller automatically selects the grasp type and size; and 3) an embedded hand controller implements the selected grasp using closed-loop position/force control. The operation of the control system was tested in 13 healthy subjects who used Cyberhand, attached to the forearm, to grasp and transport 18 objects placed at two different distances. Results The system correctly estimated grasp type and size (nine commands in total) in about 84% of the trials. In an additional 6% of the trials, the grasp type and/or size were different from the optimal ones, but they were still good enough for the grasp to be successful. If the control task was simplified by decreasing the number of possible commands, the classification accuracy increased (e.g., 93% for guessing the grasp type only). Conclusions The original outcome of this research is a novel controller empowered by vision and reasoning and capable of high-level analysis (i.e., determining object properties) and autonomous decision making (i.e., selecting the grasp type and size). The automatic control eases the burden from the user and, as a result, the user can concentrate on what he/she does, not on how he/she should do it. The tests showed that the performance of the controller was satisfactory and that the users were able to operate the system with minimal prior training. PMID:20731834

  16. A color-coded vision scheme for robotics

    NASA Technical Reports Server (NTRS)

    Johnson, Kelley Tina

    1991-01-01

    Most vision systems for robotic applications rely entirely on the extraction of information from gray-level images. Humans, however, regularly depend on color to discriminate between objects. Therefore, the inclusion of color in a robot vision system seems a natural extension of the existing gray-level capabilities. A method for robot object recognition using a color-coding classification scheme is discussed. The scheme is based on an algebraic system in which a two-dimensional color image is represented as a polynomial of two variables. The system is then used to find the color contour of objects. In a controlled environment, such as that of the in-orbit space station, a particular class of objects can thus be quickly recognized by its color.

  17. An Analysis of Helicopter Pilot Scan Techniques While Flying at Low Altitudes and High Speed

    DTIC Science & Technology

    2012-09-01

    Manager SV Synthetic Vision TFH Total Flight Hours TOFT Tactical Operational Flight Trainer VFR Visual Flight Rules VMC Visual Meteorological...Crognale, 2008). Recently, the use of synthetic vision (SV) and a heads-up- display (HUD) have been a topic of discussion in the aviation community... Synthetic vision uses external cameras to provide the pilot with an enhanced view of the outside world, usually with the assistance of night vision

  18. Fast and robust generation of feature maps for region-based visual attention.

    PubMed

    Aziz, Muhammad Zaheer; Mertsching, Bärbel

    2008-05-01

    Visual attention is one of the important phenomena in biological vision which can be followed to achieve more efficiency, intelligence, and robustness in artificial vision systems. This paper investigates a region-based approach that performs pixel clustering prior to the processes of attention in contrast to late clustering as done by contemporary methods. The foundation steps of feature map construction for the region-based attention model are proposed here. The color contrast map is generated based upon the extended findings from the color theory, the symmetry map is constructed using a novel scanning-based method, and a new algorithm is proposed to compute a size contrast map as a formal feature channel. Eccentricity and orientation are computed using the moments of obtained regions and then saliency is evaluated using the rarity criteria. The efficient design of the proposed algorithms allows incorporating five feature channels while maintaining a processing rate of multiple frames per second. Another salient advantage over the existing techniques is the reusability of the salient regions in the high-level machine vision procedures due to preservation of their shapes and precise locations. The results indicate that the proposed model has the potential to efficiently integrate the phenomenon of attention into the main stream of machine vision and systems with restricted computing resources such as mobile robots can benefit from its advantages.

  19. Software architecture for time-constrained machine vision applications

    NASA Astrophysics Data System (ADS)

    Usamentiaga, Rubén; Molleda, Julio; García, Daniel F.; Bulnes, Francisco G.

    2013-01-01

    Real-time image and video processing applications require skilled architects, and recent trends in the hardware platform make the design and implementation of these applications increasingly complex. Many frameworks and libraries have been proposed or commercialized to simplify the design and tuning of real-time image processing applications. However, they tend to lack flexibility, because they are normally oriented toward particular types of applications, or they impose specific data processing models such as the pipeline. Other issues include large memory footprints, difficulty for reuse, and inefficient execution on multicore processors. We present a novel software architecture for time-constrained machine vision applications that addresses these issues. The architecture is divided into three layers. The platform abstraction layer provides a high-level application programming interface for the rest of the architecture. The messaging layer provides a message-passing interface based on a dynamic publish/subscribe pattern. A topic-based filtering in which messages are published to topics is used to route the messages from the publishers to the subscribers interested in a particular type of message. The application layer provides a repository for reusable application modules designed for machine vision applications. These modules, which include acquisition, visualization, communication, user interface, and data processing, take advantage of the power of well-known libraries such as OpenCV, Intel IPP, or CUDA. Finally, the proposed architecture is applied to a real machine vision application: a jam detector for steel pickling lines.

  20. Serum low-density lipoprotein cholesterol level is strong risk factor for acquired color vision impairment in young to middle-aged Japanese men: the Okubo Color Study Report 2.

    PubMed

    Shoji, Takuhei; Sakurai, Yutaka; Sato, Hiroki; Chihara, Etsuo; Ishida, Masahiro; Omae, Kazuyuki

    2010-06-01

    To investigate associations between blood low-density lipoprotein cholesterol (LDL-C) levels and the prevalence of acquired color vision impairment (ACVI) in middle-aged Japanese men. Participants in this cross-sectional study underwent color vision testing, ophthalmic examination, a standardized interview and examination of venous blood samples. Ishihara plates, a Lanthony 15-hue desaturated panel, and Standard pseudoisochromatic Plates part 2 were used to examine color vision ability. The Farnsworth-Munsell 100-hue test was performed to define ACVI. Smoking status and alcohol intake were recorded during the interview. We performed logistic regression analysis adjusted for age, LDL-C level, systemic hypertension, diabetes, cataract, glaucoma, overweight, smoking status, and alcohol intake. Adjusted odds ratios for four LDL-C levels were calculated. A total of 1042 men were enrolled, 872 participants were eligible for the study, and 31 subjects were diagnosed with ACVI. As compared to the lowest LDL-C category level (<100 mg/dl), the crude OR of ACVI was 3.85 (95% confidence interval [CI], 1.24-11.00) for the 2nd highest category (130-159 mg/dl), and 4.84 (95% CI, 1.42-16.43) for the highest level (>or=160 mg/dl). The multiple-adjusted ORs were 2.91 (95% CI, 0.87-9.70) for the 2nd highest category and 3.81 (95% CI, 1.03-14.05) for the highest level. Tests for trend were significant (P<0.05) in both analyses. These findings suggested that the prevalence of ACVI is higher among middle-aged Japanese men with elevated LDL-C levels. These changes might be related to deteriorated neurologic function associated with lipid metabolite abnormalities. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  1. Solar sail science mission applications and advancement

    NASA Astrophysics Data System (ADS)

    Macdonald, Malcolm; McInnes, Colin

    2011-12-01

    Solar sailing has long been envisaged as an enabling or disruptive technology. The promise of open-ended missions allows consideration of radically new trajectories and the delivery of spacecraft to previously unreachable or unsustainable observation outposts. A mission catalogue is presented of an extensive range of potential solar sail applications, allowing identification of the key features of missions which are enabled, or significantly enhance, through solar sail propulsion. Through these considerations a solar sail application-pull technology development roadmap is established, using each mission as a technology stepping-stone to the next. Having identified and developed a solar sail application-pull technology development roadmap, this is incorporated into a new vision for solar sailing. The development of new technologies, especially for space applications, is high-risk. The advancement difficulty of low technology readiness level research is typically underestimated due to a lack of recognition of the advancement degree of difficulty scale. Recognising the currently low technology readiness level of traditional solar sailing concepts, along with their high advancement degree of difficulty and a lack of near-term applications a new vision for solar sailing is presented which increases the technology readiness level and reduces the advancement degree of difficulty of solar sailing. Just as the basic principles of solar sailing are not new, they have also been long proven and utilised in spacecraft as a low-risk, high-return limited-capability propulsion system. It is therefore proposed that this significant heritage be used to enable rapid, near-term solar sail future advancement through coupling currently mature solar sail, and other, technologies with current solar sail technology developments. As such the near-term technology readiness level of traditional solar sailing is increased, while simultaneously reducing the advancement degree of difficulty along the solar sail application-pull technology development roadmap.

  2. Examining Teacher Agency: Why Did Les Leave the Building?

    ERIC Educational Resources Information Center

    Vaughn, Margaret

    2013-01-01

    Effective teachers have been described as possessing a vision for their teaching. However, the current high-stakes accountability climate has provided challenges for teachers attempting to align their instruction with their vision for teaching. The goal of this study was to explore 3 in-service teachers' visions and perceived obstacles they faced…

  3. Property-driven functional verification technique for high-speed vision system-on-chip processor

    NASA Astrophysics Data System (ADS)

    Nshunguyimfura, Victor; Yang, Jie; Liu, Liyuan; Wu, Nanjian

    2017-04-01

    The implementation of functional verification in a fast, reliable, and effective manner is a challenging task in a vision chip verification process. The main reason for this challenge is the stepwise nature of existing functional verification techniques. This vision chip verification complexity is also related to the fact that in most vision chip design cycles, extensive efforts are focused on how to optimize chip metrics such as performance, power, and area. Design functional verification is not explicitly considered at an earlier stage at which the most sound decisions are made. In this paper, we propose a semi-automatic property-driven verification technique. The implementation of all verification components is based on design properties. We introduce a low-dimension property space between the specification space and the implementation space. The aim of this technique is to speed up the verification process for high-performance parallel processing vision chips. Our experimentation results show that the proposed technique can effectively improve the verification effort up to 20% for the complex vision chip design while reducing the simulation and debugging overheads.

  4. Preparation of an Ultrafine Rebamipide Ophthalmic Suspension with High Transparency.

    PubMed

    Matsuda, Takakuni; Hiraoka, Shogo; Urashima, Hiroki; Ogura, Ako; Ishida, Tatsuhiro

    2017-01-01

    A 2% commercially available, milky-white, rebamipide micro-particle suspension is used to treat dry eyes, and it causes short-term blurring of the patient's vision. In the current study, to improve the transparency of a rebamipide suspension, we attempted to obtain a clear rebamipide suspension by transforming the rebamipide particles to an ultrafine state. In the initial few efforts, various rebamipide suspensions were prepared using a neutralizing crystallization method with additives, but the suspensions retained their opaque quality. However, as a consequence of several critical improvements in the neutralizing crystallization methods such as selection of additives for crystallization, process parameters during crystallization, the dispersion method, and dialysis, we obtained an ultrafine rebamipide suspension (2%) that was highly transparent (transmittance at 640 nm: 59%). The particle size and transparency demonstrated the fewest level of changes at 25°C after 3 years, compared to initial levels. During that period, no obvious particle sedimentation was observed. The administration of this ultrafine rebamipide suspension (2%) increased the conjunctival mucin, which was comparable to the commercially available micro-particle suspension (2%). The corneal and conjunctival concentration of rebamipide following ocular administration of the ultrafine suspension was slightly higher than that of the micro-particle suspension. The ultrafine rebamipide suspension (eye-drop formulation) with a highly transparent ophthalmic clearness should improve a patient's QOL by preventing even a shortened period of blurred vision.

  5. Exploring the patient perspective of fatigue in adults with visual impairment: a qualitative study.

    PubMed

    Schakel, Wouter; Bode, Christina; van der Aa, Hilde P A; Hulshof, Carel T J; Bosmans, Judith E; van Rens, Gerardus H M B; van Nispen, Ruth M A

    2017-08-03

    Fatigue is an often mentioned symptom by patients with irreversible visual impairment. This study explored the patient perspective of fatigue in visually impaired adults with a focus on symptoms of fatigue, causes, consequences and coping strategies. Two large Dutch low vision multidisciplinary rehabilitation organisations. 16 visually impaired adults with severe symptoms of fatigue selected by purposive sampling. A qualitative study involving semistructured interviews. A total of four first-level codes were top-down predetermined in correspondence with the topics of the research question. Verbatim transcribed interviews were analysed with a combination of a deductive and inductive approach using open and axial coding. Participants often described the symptoms of fatigue as a mental, daily and physical experience. The most often mentioned causes of fatigue were a high cognitive load, the intensity and amount of activities, the high effort necessary to establish visual perception, difficulty with light intensity and negative cognitions. Fatigue had the greatest impact on the ability to carry out social roles and participation, emotional functioning and cognitive functioning. The most common coping strategies were relaxation, external support, socialising and physical exercise and the acceptance of fatigue. Our results indicate that low vision-related fatigue is mainly caused by population specific determinants that seem different from the fatigue experience described in studies with other patient populations. Fatigue may be central to the way patients react, adapt and compensate to the consequences of vision loss. These findings indicate a need for future research aimed at interventions specifically tailored to the unique aspects of fatigue related to vision loss. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Night Vision Camera

    NASA Technical Reports Server (NTRS)

    1996-01-01

    PixelVision, Inc. developed the Night Video NV652 Back-illuminated CCD Camera, based on the expertise of a former Jet Propulsion Laboratory employee and a former employee of Scientific Imaging Technologies, Inc. The camera operates without an image intensifier, using back-illuminated and thinned CCD technology to achieve extremely low light level imaging performance. The advantages of PixelVision's system over conventional cameras include greater resolution and better target identification under low light conditions, lower cost and a longer lifetime. It is used commercially for research and aviation.

  7. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration

    PubMed Central

    Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W.; Jackson, Mary Lou

    2018-01-01

    Purpose Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. Methods We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Results Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). Conclusion In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL. PMID:29746512

  8. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration.

    PubMed

    Roh, Miin; Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W; Jackson, Mary Lou

    2018-01-01

    Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL.

  9. GSFC Information Systems Technology Developments Supporting the Vision for Space Exploration

    NASA Technical Reports Server (NTRS)

    Hughes, Peter; Dennehy, Cornelius; Mosier, Gary; Smith, Dan; Rykowski, Lisa

    2004-01-01

    The Vision for Space Exploration will guide NASA's future human and robotic space activities. The broad range of human and robotic missions now being planned will require the development of new system-level capabilities enabled by emerging new technologies. Goddard Space Flight Center is actively supporting the Vision for Space Exploration in a number of program management, engineering and technology areas. This paper provides a brief background on the Vision for Space Exploration and a general overview of potential key Goddard contributions. In particular, this paper focuses on describing relevant GSFC information systems capabilities in architecture development; interoperable command, control and communications; and other applied information systems technology/research activities that are applicable to support the Vision for Space Exploration goals. Current GSFC development efforts and task activities are presented together with future plans.

  10. Implementation of a robotic flexible assembly system

    NASA Technical Reports Server (NTRS)

    Benton, Ronald C.

    1987-01-01

    As part of the Intelligent Task Automation program, a team developed enabling technologies for programmable, sensory controlled manipulation in unstructured environments. These technologies include 2-D/3-D vision sensing and understanding, force sensing and high speed force control, 2.5-D vision alignment and control, and multiple processor architectures. The subsequent design of a flexible, programmable, sensor controlled robotic assembly system for small electromechanical devices is described using these technologies and ongoing implementation and integration efforts. Using vision, the system picks parts dumped randomly in a tray. Using vision and force control, it performs high speed part mating, in-process monitoring/verification of expected results and autonomous recovery from some errors. It is programmed off line with semiautomatic action planning.

  11. Compact VLSI neural computer integrated with active pixel sensor for real-time ATR applications

    NASA Astrophysics Data System (ADS)

    Fang, Wai-Chi; Udomkesmalee, Gabriel; Alkalai, Leon

    1997-04-01

    A compact VLSI neural computer integrated with an active pixel sensor has been under development to mimic what is inherent in biological vision systems. This electronic eye- brain computer is targeted for real-time machine vision applications which require both high-bandwidth communication and high-performance computing for data sensing, synergy of multiple types of sensory information, feature extraction, target detection, target recognition, and control functions. The neural computer is based on a composite structure which combines Annealing Cellular Neural Network (ACNN) and Hierarchical Self-Organization Neural Network (HSONN). The ACNN architecture is a programmable and scalable multi- dimensional array of annealing neurons which are locally connected with their local neurons. Meanwhile, the HSONN adopts a hierarchical structure with nonlinear basis functions. The ACNN+HSONN neural computer is effectively designed to perform programmable functions for machine vision processing in all levels with its embedded host processor. It provides a two order-of-magnitude increase in computation power over the state-of-the-art microcomputer and DSP microelectronics. A compact current-mode VLSI design feasibility of the ACNN+HSONN neural computer is demonstrated by a 3D 16X8X9-cube neural processor chip design in a 2-micrometers CMOS technology. Integration of this neural computer as one slice of a 4'X4' multichip module into the 3D MCM based avionics architecture for NASA's New Millennium Program is also described.

  12. Evolution of colour vision in mammals.

    PubMed

    Jacobs, Gerald H

    2009-10-12

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision.

  13. Evolution of colour vision in mammals

    PubMed Central

    Jacobs, Gerald H.

    2009-01-01

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision. PMID:19720656

  14. Evolution of Vision

    NASA Astrophysics Data System (ADS)

    Ostrovsky, Mikhail

    The evolution of photoreception, giving rise to eye, offers a kaleidoscopic view on selection acting at both the organ and molecular levels. The molecular level is mainly considered in the lecture. The greatest progress to date has been made in relation to the opsin visual pigments. Opsins appeared before eyes did. Two- and three-dimensional organization for rhodopsin in the rod outer segment disk membrane, as well as molecular mechanisms of visual pigments spectral tuning, photoisomerization and also opsin as a G-protein coupled receptor are considered. Molecular mechanisms of visual pigments spectral tuning, namely switching of chromophore (physiological time scale) and amino acid changes in the chromophore site of opsin (evolutionary time scale) is considered in the lecture. Photoisomerization of rhodopsin chromophore, 11-cis retinal is the only photochemical reaction in vision. The reaction is extemely fast (less that 200 fs) and high efficient (. is 0.65). The rhodopsin photolysis and kinetics of the earlier products appearance, photo- and bathorhodopsin, is considered. It is known that light is not only a carrier of information, but also a risk factor of damage to the eye. This photobiological paradox of vision is mainly due to the nature of rhodopsin chromophore. Photooxidation is the base of the paradox. All factors present in the phototrceptor cells to initiate free-radical photooxidation: photosensitizers, oxygen and substrates of oxidation: lipids and proteins (opsin). That is why photoprotective system of the eye structures appeared in the course of evolution. Three lines of protective system to prevent light damage to the retina and retina pigment epithelium is known: permanent renewal of rod and cone outer segment, powerful antioxidant system and optical media as cut-off filters where the lens is a key component. The molecular mechanisms of light damage to the eye and photoprotective system of the eye is considered in the lecture. The molecular mechanisms of phototransduction in vertebrates eye is also briefly considered in the lecture. Evolution of vision is an enormous subject for thought and investigation. In the postgenomic era evolutionary molecular physiology as a whole and evolutionary molecular physiology of vision can be considered as a key approach for understanding how genome is working.

  15. Factors associated with impaired color vision without retinopathy amongst people with type 2 diabetes mellitus: a cross-sectional study.

    PubMed

    Tan, N C; Yip, W F; Kallakuri, S; Sankari, U; Koh, Y L E

    2017-06-02

    Patients with type 2 diabetes mellitus (T2DM) may develop color vision impairment. This study aimed to determine the prevalence and factors associated with impaired color vision in patients with T2DM but without diabetic retinopathy. Enrolment criteria included multi-ethnic Asian participants, age 21 to 80 years, with known T2DM for a minimum of 2 years. Their diagnoses were affirmed from oral glucose tolerance test results and they were screened for impaired color vision using the Farnsworth D-15 instrument. Demographic characteristics were described and clinical data for the preceding 2 years were analyzed using logistic regression. Twenty-two percent of 849 eligible participants had impaired color vision with higher involvement of the right eye. Impaired blue-yellow color-vision(Tritanomaly) was the commonest impaired color vision. Participants with impaired color vision were significantly associated with age and lower education; longer duration of T2DM (median 6 years vs 4 years); higher HbA1c level and HDL-Cholesterol in 2nd year; lower mean total cholesterol, mean LDL-Cholesterol and mean triglyceride in 2nd year. They also have poorer vision beyond 6/12 in the affected eye. Logistic regression showed that impaired color vision was associated with older patients (OR=1.04), increased duration of T2DM (OR=1.07); prescription of Tolbutamide (OR=3.79) and lower mean systolic blood pressure (OR=0.98). Almost one in four participants with T2DM had impaired color vision, largely with tritanomaly. Color vision screening may be considered for participants who develop T2DM for 6 years or longer, but this requires further cost-effectiveness evaluation.

  16. Near vision spectacle coverage and barriers to near vision correction among adults in the Cape Coast Metropolis of Ghana.

    PubMed

    Ntodie, Michael; Abu, Sampson L; Kyei, Samuel; Abokyi, Samuel; Abu, Emmanuel K

    2017-06-01

    To determine the near vision spectacle coverage and barriers to obtaining near vision correction among adults aged 35 years and older in the Cape Coast Metropolis of Ghana. A population-based cross-sectional study design was adopted and 500 out of 576 participants aged 35 years and older were examined from 12 randomly selected clusters in Cape Coast, Ghana. All participants underwent a comprehensive eye examination which included: distance and near visual acuities measurements and external and internal ocular health assessments. Distance and near refractions were performed using subjective refraction technique. Information on participants' demographics, near vision correction status, near visual needs and barriers to acquiring near vision correction were obtained through a questionnaire administered as part of the study. The mean age of participants was 52.3±10.3 years of whom 280 (56%) were females and 220 (44%) were males. The near vision spectacle coverage was 25%, 33% "met need" for near vision correction in the presbyopic population, and 64% unmet need in the entire study population. After controlling for other variables, age (5 th and 6 th decades) and educational level were associated with "met need" for near vision correction (OR=2.7 (1.55-4.68), p =0.00, and OR=2.36 (1.18-4.72), p=0.02 respectively). Among those who needed but did not have near vision correction, 64 (26%) did not feel the need for correction, 55 (22%) stated that they were unaware of available interventions, and 53 (21%) found the cost of near vision correction prohibitive. There was a low near vision spectacle coverage in this population which suggests the need for strategies on health education and promotion to address the lack of awareness of spectacle need and cost of services.

  17. Global Perspectives on Teaching Literature: Shared Visions and Distinctive Visions.

    ERIC Educational Resources Information Center

    Lott, Sandra Ward, Ed.; And Others

    This book is a collection of essays designed for high school and college teachers who want to introduce non-Western and other non-canonical texts into their traditional literature courses. The essays in the book explore the kinds of visions encountered when teachers cluster Western texts with those outside the dominant Western tradition. Papers in…

  18. Perceptual organization in computer vision - A review and a proposal for a classificatory structure

    NASA Technical Reports Server (NTRS)

    Sarkar, Sudeep; Boyer, Kim L.

    1993-01-01

    The evolution of perceptual organization in biological vision, and its necessity in advanced computer vision systems, arises from the characteristic that perception, the extraction of meaning from sensory input, is an intelligent process. This is particularly so for high order organisms and, analogically, for more sophisticated computational models. The role of perceptual organization in computer vision systems is explored. This is done from four vantage points. First, a brief history of perceptual organization research in both humans and computer vision is offered. Next, a classificatory structure in which to cast perceptual organization research to clarify both the nomenclature and the relationships among the many contributions is proposed. Thirdly, the perceptual organization work in computer vision in the context of this classificatory structure is reviewed. Finally, the array of computational techniques applied to perceptual organization problems in computer vision is surveyed.

  19. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment.

    PubMed

    Allen, Peter M; Latham, Keziah; Mann, David L; Ravensbergen, Rianne H J C; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual's average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving 'expected' or 'below expected' shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the sport. An impairment to CS could impact performance in the sport and might be considered in determining eligibility to take part in VI competition.

  20. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment

    PubMed Central

    Allen, Peter M.; Latham, Keziah; Mann, David L.; Ravensbergen, Rianne H. J. C.; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual’s average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving ‘expected’ or ‘below expected’ shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the sport. An impairment to CS could impact performance in the sport and might be considered in determining eligibility to take part in VI competition. PMID:27877150

  1. Change in vision, visual disability, and health after cataract surgery.

    PubMed

    Helbostad, Jorunn L; Oedegaard, Maria; Lamb, Sarah E; Delbaere, Kim; Lord, Stephen R; Sletvold, Olav

    2013-04-01

    Cataract surgery improves vision and visual functioning; the effect on general health is not established. We investigated if vision, visual functioning, and general health follow the same trajectory of change the year after cataract surgery and if changes in vision explain changes in visual disability and general health. One-hundred forty-eight persons, with a mean (SD) age of 78.9 (5.0) years (70% bilateral surgery), were assessed before and 6 weeks and 12 months after surgery. Visual disability and general health were assessed by the CatQuest-9SF and the Short Formular-36. Corrected binocular visual acuity, visual field, stereo acuity, and contrast vision improved (P < 0.001) from before to 6 weeks after surgery, with further improvements of visual acuity evident up to 12 months (P = 0.034). Cataract surgery had an effect on visual disability 1 year later (P < 0.001). Physical and mental health improved after surgery (P < 0.01) but had returned to presurgery level after 12 months. Vision changes did not explain visual disability and general health 6 weeks after surgery. Vision improved and visual disability decreased in the year after surgery, whereas changes in general health and visual functioning were short-term effects. Lack of associations between changes in vision and self-reported disability and general health suggests that the degree of vision changes and self-reported health do not have a linear relationship.

  2. Mission Design for the Innovative Interstellar Explorer Vision Mission

    NASA Technical Reports Server (NTRS)

    Fiehler, Douglas I.; McNutt, Ralph L.

    2005-01-01

    The Innovative Interstellar Explorer, studied under a NASA Vision Mission grant, examined sending a probe to a heliospheric distance of 200 Astronomical Units (AU) in a "reasonable" amount of time. Previous studies looked at the use of a near-Sun propulsive maneuver, solar sails, and fission reactor powered electric propulsion systems for propulsion. The Innovative Interstellar Explorer's mission design used a combination of a high-energy launch using current launch technology, a Jupiter gravity assist, and electric propulsion powered by advanced radioisotope power systems to reach 200 AU. Many direct and gravity assist trajectories at several power levels were considered in the development of the baseline trajectory, including single and double gravity assists utilizing the outer planets (Jupiter, Saturn, Uranus, and Neptune). A detailed spacecraft design study was completed followed by trajectory analyses to examine the performance of the spacecraft design options.

  3. Real-time model-based vision system for object acquisition and tracking

    NASA Technical Reports Server (NTRS)

    Wilcox, Brian; Gennery, Donald B.; Bon, Bruce; Litwin, Todd

    1987-01-01

    A machine vision system is described which is designed to acquire and track polyhedral objects moving and rotating in space by means of two or more cameras, programmable image-processing hardware, and a general-purpose computer for high-level functions. The image-processing hardware is capable of performing a large variety of operations on images and on image-like arrays of data. Acquisition utilizes image locations and velocities of the features extracted by the image-processing hardware to determine the three-dimensional position, orientation, velocity, and angular velocity of the object. Tracking correlates edges detected in the current image with edge locations predicted from an internal model of the object and its motion, continually updating velocity information to predict where edges should appear in future frames. With some 10 frames processed per second, real-time tracking is possible.

  4. An Imaging Sensor-Aided Vision Navigation Approach that Uses a Geo-Referenced Image Database.

    PubMed

    Li, Yan; Hu, Qingwu; Wu, Meng; Gao, Yang

    2016-01-28

    In determining position and attitude, vision navigation via real-time image processing of data collected from imaging sensors is advanced without a high-performance global positioning system (GPS) and an inertial measurement unit (IMU). Vision navigation is widely used in indoor navigation, far space navigation, and multiple sensor-integrated mobile mapping. This paper proposes a novel vision navigation approach aided by imaging sensors and that uses a high-accuracy geo-referenced image database (GRID) for high-precision navigation of multiple sensor platforms in environments with poor GPS. First, the framework of GRID-aided vision navigation is developed with sequence images from land-based mobile mapping systems that integrate multiple sensors. Second, a highly efficient GRID storage management model is established based on the linear index of a road segment for fast image searches and retrieval. Third, a robust image matching algorithm is presented to search and match a real-time image with the GRID. Subsequently, the image matched with the real-time scene is considered to calculate the 3D navigation parameter of multiple sensor platforms. Experimental results show that the proposed approach retrieves images efficiently and has navigation accuracies of 1.2 m in a plane and 1.8 m in height under GPS loss in 5 min and within 1500 m.

  5. An Imaging Sensor-Aided Vision Navigation Approach that Uses a Geo-Referenced Image Database

    PubMed Central

    Li, Yan; Hu, Qingwu; Wu, Meng; Gao, Yang

    2016-01-01

    In determining position and attitude, vision navigation via real-time image processing of data collected from imaging sensors is advanced without a high-performance global positioning system (GPS) and an inertial measurement unit (IMU). Vision navigation is widely used in indoor navigation, far space navigation, and multiple sensor-integrated mobile mapping. This paper proposes a novel vision navigation approach aided by imaging sensors and that uses a high-accuracy geo-referenced image database (GRID) for high-precision navigation of multiple sensor platforms in environments with poor GPS. First, the framework of GRID-aided vision navigation is developed with sequence images from land-based mobile mapping systems that integrate multiple sensors. Second, a highly efficient GRID storage management model is established based on the linear index of a road segment for fast image searches and retrieval. Third, a robust image matching algorithm is presented to search and match a real-time image with the GRID. Subsequently, the image matched with the real-time scene is considered to calculate the 3D navigation parameter of multiple sensor platforms. Experimental results show that the proposed approach retrieves images efficiently and has navigation accuracies of 1.2 m in a plane and 1.8 m in height under GPS loss in 5 min and within 1500 m. PMID:26828496

  6. Application of the SP theory of intelligence to the understanding of natural vision and the development of computer vision.

    PubMed

    Wolff, J Gerard

    2014-01-01

    The SP theory of intelligence aims to simplify and integrate concepts in computing and cognition, with information compression as a unifying theme. This article is about how the SP theory may, with advantage, be applied to the understanding of natural vision and the development of computer vision. Potential benefits include an overall simplification of concepts in a universal framework for knowledge and seamless integration of vision with other sensory modalities and other aspects of intelligence. Low level perceptual features such as edges or corners may be identified by the extraction of redundancy in uniform areas in the manner of the run-length encoding technique for information compression. The concept of multiple alignment in the SP theory may be applied to the recognition of objects, and to scene analysis, with a hierarchy of parts and sub-parts, at multiple levels of abstraction, and with family-resemblance or polythetic categories. The theory has potential for the unsupervised learning of visual objects and classes of objects, and suggests how coherent concepts may be derived from fragments. As in natural vision, both recognition and learning in the SP system are robust in the face of errors of omission, commission and substitution. The theory suggests how, via vision, we may piece together a knowledge of the three-dimensional structure of objects and of our environment, it provides an account of how we may see things that are not objectively present in an image, how we may recognise something despite variations in the size of its retinal image, and how raster graphics and vector graphics may be unified. And it has things to say about the phenomena of lightness constancy and colour constancy, the role of context in recognition, ambiguities in visual perception, and the integration of vision with other senses and other aspects of intelligence.

  7. Do type 2 diabetes patients without diabetic retinopathy or subjects with impaired fasting glucose have impaired colour vision? The Okubo Color Study Report.

    PubMed

    Shoji, T; Sakurai, Y; Sato, H; Chihara, E; Takeuchi, M

    2011-07-01

    To investigate associations between fasting plasma glucose level and the prevalence of acquired colour vision impairment in type 2 diabetes patients without diabetic retinopathy. Participants in this cross-sectional study of male officials aged 20-60 yr in the Japanese Self Defence Force, underwent colour vision testing, ophthalmic examination, a standardized interview and examination of venous blood samples. Ishihara plates, a Lanthony 15-hue desaturated panel and Standard Pseudoisochromatic Plates Part 2 were used to examine colour vision. The Farnsworth-Munsell 100-hue test was performed to define acquired colour vision impairment. Cardiovascular disease risk factors were determined from serum blood samples, physical records and an interview. We performed logistic regression analysis adjusted for age, diagnosed hypertension, dyslipidaemia, cataract, glaucoma, being overweight, smoking status and alcohol intake. Crude and adjusted odds ratios were calculated for three glucose levels, which included normal fasting glucose, impaired fasting glucose and diabetes. Out of a total of 1042 men enrolled, 872 were eligible for the study, and 31 were diagnosed with acquired colour vision impairment. As compared with the subjects with normal fasting glucose (< 5.6 mmol/l), the crude odds ratio for acquired colour vision impairment was 0.93 (95% CI 0.32-2.74) for the subjects with impaired fasting glucose (5.6-6.9 mmol/l) and 8.07 (95% CI 2.48-26.22) for the patients with type 2 diabetes. The multiple-adjusted odds ratios were 0.77 (95% CI 0.25-2.34) for the subjects with impaired fasting glucose and 5.89 (95% CI 1.55-22.40) for the patients with type 2 diabetes. Our findings suggest that there is a dramatically increased prevalence of acquired colour vision impairment in type 2 diabetes patients without diabetic retinopathy which might be attributable to another pathogenesis associated with diabetic retinopathy. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  8. High-throughput measurements of biochemical responses using the plate::vision multimode 96 minilens array reader.

    PubMed

    Huang, Kuo-Sen; Mark, David; Gandenberger, Frank Ulrich

    2006-01-01

    The plate::vision is a high-throughput multimode reader capable of reading absorbance, fluorescence, fluorescence polarization, time-resolved fluorescence, and luminescence. Its performance has been shown to be quite comparable with other readers. When the reader is integrated into the plate::explorer, an ultrahigh-throughput screening system with event-driven software and parallel plate-handling devices, it becomes possible to run complicated assays with kinetic readouts in high-density microtiter plate formats for high-throughput screening. For the past 5 years, we have used the plate::vision and the plate::explorer to run screens and have generated more than 30 million data points. Their throughput, performance, and robustness have speeded up our drug discovery process greatly.

  9. High-Resolution Adaptive Optics Test-Bed for Vision Science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilks, S C; Thomspon, C A; Olivier, S S

    2001-09-27

    We discuss the design and implementation of a low-cost, high-resolution adaptive optics test-bed for vision research. It is well known that high-order aberrations in the human eye reduce optical resolution and limit visual acuity. However, the effects of aberration-free eyesight on vision are only now beginning to be studied using adaptive optics to sense and correct the aberrations in the eye. We are developing a high-resolution adaptive optics system for this purpose using a Hamamatsu Parallel Aligned Nematic Liquid Crystal Spatial Light Modulator. Phase-wrapping is used to extend the effective stroke of the device, and the wavefront sensing and wavefrontmore » correction are done at different wavelengths. Issues associated with these techniques will be discussed.« less

  10. Learning disabilities, dyslexia, and vision: a subject review--a rebuttal, literature review, and commentary.

    PubMed

    Bowan, Merrill D

    2002-09-01

    In 1998, the American Academy of Pediatrics, the American Academy of Ophthalmology, and the American Association of Pediatric Ophthalmology and Strabismus (AAP/AAO/AAPOS) published a position paper entitled "Learning Disabilities, Dyslexia And Vision: A Subject Review," intended to support their assertion that there is no relationship between learning disabilities, dyslexia, and vision. The paper presents an unsupported opinion that optometrists (by implication) have said that vision problems cause learning disabilities and/or dyslexia and that visual therapy cures the conditions. The 1998 position paper follows two very similar and discredited papers published in 1972 and 1981. This article critically reviews and comments on the many problems of scholarship, the inconsistencies, and the false allegations the position paper presents. Perhaps the foremost problem is that the authoring committee has ignored a veritable mountain of relevant literature that strongly argues against their assertion that vision does not relate to academic performance. It is for this reason that an overview, drawn from more than 1,400 identified references from Medline and other database sources and pertinent texts that were reviewed, is incorporated into this current article. The AAP/AAO/AAPOS paper is also examined for the Levels of Evidence that their references offer in support of their position. The AAP/AAO/AAPOS paper contains errors and internal inconsistencies. Through highly selective reference choices, it misrepresents the great body of evidence from the literature that supports a relationship between visual and perceptual problems as they contribute to classroom difficulties. The 1998 paper should be retracted because of the errors, bias, and disinformation it presents. The public assigns great trust to authorities for accurate, intellectually honest guidance, which is lacking in this AAP/AAO/AAPOS position paper.

  11. Information-Theoretic Approach May Shed a Light to a Better Understanding and Sustaining the Integrity of Ecological-Societal Systems under Changing Climate

    NASA Astrophysics Data System (ADS)

    Kim, J.

    2016-12-01

    Considering high levels of uncertainty, epistemological conflicts over facts and values, and a sense of urgency, normal paradigm-driven science will be insufficient to mobilize people and nation toward sustainability. The conceptual framework to bridge the societal system dynamics with that of natural ecosystems in which humanity operates remains deficient. The key to understanding their coevolution is to understand `self-organization.' Information-theoretic approach may shed a light to provide a potential framework which enables not only to bridge human and nature but also to generate useful knowledge for understanding and sustaining the integrity of ecological-societal systems. How can information theory help understand the interface between ecological systems and social systems? How to delineate self-organizing processes and ensure them to fulfil sustainability? How to evaluate the flow of information from data through models to decision-makers? These are the core questions posed by sustainability science in which visioneering (i.e., the engineering of vision) is an essential framework. Yet, visioneering has neither quantitative measure nor information theoretic framework to work with and teach. This presentation is an attempt to accommodate the framework of self-organizing hierarchical open systems with visioneering into a common information-theoretic framework. A case study is presented with the UN/FAO's communal vision of climate-smart agriculture (CSA) which pursues a trilemma of efficiency, mitigation, and resilience. Challenges of delineating and facilitating self-organizing systems are discussed using transdisciplinary toold such as complex systems thinking, dynamic process network analysis and multi-agent systems modeling. Acknowledgments: This study was supported by the Korea Meteorological Administration Research and Development Program under Grant KMA-2012-0001-A (WISE project).

  12. Color vision with rapid-onset acceleration.

    PubMed

    Balldin, U I; Derefeldt, G; Eriksson, L; Werchan, P M; Andersson, P; Yates, J T

    2003-01-01

    Only sporadic information exists concerning perceived color shifts at increased G-loads. The purpose of this study was to investigate whether or not color vision is affected by rapid onset high G7-loads up to +9 Gz, and specifically whether perception of hue changes. There were 10 male subjects, 9 with normal color vision and 1 with red-green protanomaly, all accustomed to Gz-loads in a human centrifuge. Each subject was tested on a total of 60 Gz-exposures with 10 s periods at +3, +5, +7, and +9 Gz in the centrifuge on three different days. G-onset rate was 6 G x s(-1). The subjects wore an anti-G suit and performed straining maneuvers if necessary to maintain vision. Five square color stimuli of medium saturation (yellow, red, blue, green, and gray) were projected one at a time on a screen in front of the subject, who gave his hue response orally. In 96.6% of exposures to various Gz-loads, the subjects responded by correctly naming colors. (The statistical analyses of the results were done for the subjects with normal color vision, with the protanomalous subject excluded.) Hue shifts occurred at the higher +Gz-levels, including 7.7% of the +9 Gz exposures. Yellow was the hue most frequently perceived as changed. Hue shifts were reported for yellow in 11% and 16% of the +7 and +9 Gz exposures, respectively. Hue shifts at +9 Gz occurred as frequently as blackout and G-LOC together. However, statistical analyses showed no significant effects for +Gz-load. Absolute identification of the color stimuli of medium saturation was stable and was not significantly affected by the rapid onset +Gz-loads up to and including +9 Gz.

  13. Mapping in-vivo optic nerve head strains caused by intraocular and intracranial pressures

    NASA Astrophysics Data System (ADS)

    Tran, H.; Grimm, J.; Wang, B.; Smith, M. A.; Gogola, A.; Nelson, S.; Tyler-Kabara, E.; Schuman, J.; Wollstein, G.; Sigal, I. A.

    2017-02-01

    Although it is well documented that abnormal levels of either intraocular (IOP) or intracranial pressure (ICP) can lead to potentially blinding conditions, such as glaucoma and papilledema, little is known about how the pressures actually affect the eye. Even less is known about potential interplay between their effects, namely how the level of one pressure might alter the effects of the other. Our goal was to measure in-vivo the pressure-induced stretch and compression of the lamina cribrosa due to acute changes of IOP and ICP. The lamina cribrosa is a structure within the optic nerve head, in the back of the eye. It is important because it is in the lamina cribrosa that the pressure-induced deformations are believed to initiate damage to neural tissues leading to blindness. An eye of a rhesus macaque monkey was imaged in-vivo with optical coherence tomography while IOP and ICP were controlled through cannulas in the anterior chamber and lateral ventricle, respectively. The image volumes were analyzed with a newly developed digital image correlation technique. The effects of both pressures were highly localized, nonlinear and non-monotonic, with strong interactions. Pressure variations from the baseline normal levels caused substantial stretch and compression of the neural tissues in the posterior pole, sometimes exceeding 20%. Chronic exposure to such high levels of biomechanical insult would likely lead to neural tissue damage and loss of vision. Our results demonstrate the power of digital image correlation technique based on non-invasive imaging technologies to help understand how pressures induce biomechanical insults and lead to vision problems.

  14. The theoretical simulation on electrostatic distribution of 1st proximity region in proximity focusing low-light-level image intensifier

    NASA Astrophysics Data System (ADS)

    Zhang, Liandong; Bai, Xiaofeng; Song, De; Fu, Shencheng; Li, Ye; Duanmu, Qingduo

    2015-03-01

    Low-light-level night vision technology is magnifying low light level signal large enough to be seen by naked eye, which uses the photons - photoelectron as information carrier. Until the micro-channel plate was invented, it has been possibility for the realization of high performance and miniaturization of low-light-level night vision device. The device is double-proximity focusing low-light-level image intensifier which places a micro-channel plate close to photocathode and phosphor screen. The advantages of proximity focusing low-light-level night vision are small size, light weight, small power consumption, no distortion, fast response speed, wide dynamic range and so on. It is placed parallel to each other for Micro-channel plate (both sides of it with metal electrode), the photocathode and the phosphor screen are placed parallel to each other. The voltage is applied between photocathode and the input of micro-channel plate when image intensifier works. The emission electron excited by photo on the photocathode move towards to micro-channel plate under the electric field in 1st proximity focusing region, and then it is multiplied through the micro-channel. The movement locus of emission electrons can be calculated and simulated when the distributions of electrostatic field equipotential lines are determined in the 1st proximity focusing region. Furthermore the resolution of image tube can be determined. However the distributions of electrostatic fields and equipotential lines are complex due to a lot of micro-channel existing in the micro channel plate. This paper simulates electrostatic distribution of 1st proximity region in double-proximity focusing low-light-level image intensifier with the finite element simulation analysis software Ansoft maxwell 3D. The electrostatic field distributions of 1st proximity region are compared when the micro-channel plates' pore size, spacing and inclination angle ranged. We believe that the electron beam movement trajectory in 1st proximity region will be better simulated when the electronic electrostatic fields are simulated.

  15. GPS Usage in a Population of Low-Vision Drivers.

    PubMed

    Cucuras, Maria; Chun, Robert; Lee, Patrick; Jay, Walter M; Pusateri, Gregg

    2017-01-01

    We surveyed bioptic and non-bioptic low-vision drivers in Illinois, USA, to determine their usage of global positioning system (GPS) devices. Low-vision patients completed an IRB-approved phone survey regarding driving demographics and usage of GPS while driving. Participants were required to be active drivers with an Illinois driver's license, and met one of the following criteria: best-corrected visual acuity (BCVA) less than or equal to 20/40, central or significant peripheral visual field defects, or a combination of both. Of 27 low-vision drivers, 10 (37%) used GPS while driving. The average age for GPS users was 54.3 and for non-users was 77.6. All 10 drivers who used GPS while driving reported increased comfort or safety level. Since non-GPS users were significantly older than GPS users, it is likely that older participants would benefit from GPS technology training from their low-vision eye care professionals.

  16. Visual adaptation and face perception

    PubMed Central

    Webster, Michael A.; MacLeod, Donald I. A.

    2011-01-01

    The appearance of faces can be strongly affected by the characteristics of faces viewed previously. These perceptual after-effects reflect processes of sensory adaptation that are found throughout the visual system, but which have been considered only relatively recently in the context of higher level perceptual judgements. In this review, we explore the consequences of adaptation for human face perception, and the implications of adaptation for understanding the neural-coding schemes underlying the visual representation of faces. The properties of face after-effects suggest that they, in part, reflect response changes at high and possibly face-specific levels of visual processing. Yet, the form of the after-effects and the norm-based codes that they point to show many parallels with the adaptations and functional organization that are thought to underlie the encoding of perceptual attributes like colour. The nature and basis for human colour vision have been studied extensively, and we draw on ideas and principles that have been developed to account for norms and normalization in colour vision to consider potential similarities and differences in the representation and adaptation of faces. PMID:21536555

  17. Visual adaptation and face perception.

    PubMed

    Webster, Michael A; MacLeod, Donald I A

    2011-06-12

    The appearance of faces can be strongly affected by the characteristics of faces viewed previously. These perceptual after-effects reflect processes of sensory adaptation that are found throughout the visual system, but which have been considered only relatively recently in the context of higher level perceptual judgements. In this review, we explore the consequences of adaptation for human face perception, and the implications of adaptation for understanding the neural-coding schemes underlying the visual representation of faces. The properties of face after-effects suggest that they, in part, reflect response changes at high and possibly face-specific levels of visual processing. Yet, the form of the after-effects and the norm-based codes that they point to show many parallels with the adaptations and functional organization that are thought to underlie the encoding of perceptual attributes like colour. The nature and basis for human colour vision have been studied extensively, and we draw on ideas and principles that have been developed to account for norms and normalization in colour vision to consider potential similarities and differences in the representation and adaptation of faces.

  18. Tracking the evolution of crossmodal plasticity and visual functions before and after sight restoration

    PubMed Central

    Dormal, Giulia; Lepore, Franco; Harissi-Dagher, Mona; Albouy, Geneviève; Bertone, Armando; Rossion, Bruno

    2014-01-01

    Visual deprivation leads to massive reorganization in both the structure and function of the occipital cortex, raising crucial challenges for sight restoration. We tracked the behavioral, structural, and neurofunctional changes occurring in an early and severely visually impaired patient before and 1.5 and 7 mo after sight restoration with magnetic resonance imaging. Robust presurgical auditory responses were found in occipital cortex despite residual preoperative vision. In primary visual cortex, crossmodal auditory responses overlapped with visual responses and remained elevated even 7 mo after surgery. However, these crossmodal responses decreased in extrastriate occipital regions after surgery, together with improved behavioral vision and with increases in both gray matter density and neural activation in low-level visual regions. Selective responses in high-level visual regions involved in motion and face processing were observable even before surgery and did not evolve after surgery. Taken together, these findings demonstrate that structural and functional reorganization of occipital regions are present in an individual with a long-standing history of severe visual impairment and that such reorganizations can be partially reversed by visual restoration in adulthood. PMID:25520432

  19. Automated intelligent video surveillance system for ships

    NASA Astrophysics Data System (ADS)

    Wei, Hai; Nguyen, Hieu; Ramu, Prakash; Raju, Chaitanya; Liu, Xiaoqing; Yadegar, Jacob

    2009-05-01

    To protect naval and commercial ships from attack by terrorists and pirates, it is important to have automatic surveillance systems able to detect, identify, track and alert the crew on small watercrafts that might pursue malicious intentions, while ruling out non-threat entities. Radar systems have limitations on the minimum detectable range and lack high-level classification power. In this paper, we present an innovative Automated Intelligent Video Surveillance System for Ships (AIVS3) as a vision-based solution for ship security. Capitalizing on advanced computer vision algorithms and practical machine learning methodologies, the developed AIVS3 is not only capable of efficiently and robustly detecting, classifying, and tracking various maritime targets, but also able to fuse heterogeneous target information to interpret scene activities, associate targets with levels of threat, and issue the corresponding alerts/recommendations to the man-in- the-loop (MITL). AIVS3 has been tested in various maritime scenarios and shown accurate and effective threat detection performance. By reducing the reliance on human eyes to monitor cluttered scenes, AIVS3 will save the manpower while increasing the accuracy in detection and identification of asymmetric attacks for ship protection.

  20. Hypothalamic dysfunction

    MedlinePlus

    ... symptoms may include headache or loss of vision. Hypothyroidism symptoms may include feeling cold all the time, ... Vision disorders Problems controlling salt and water balance HYPOTHYROIDISM Heart problems High cholesterol ADRENAL INSUFFICIENCY Inability to ...

  1. A compact high-definition low-cost digital stereoscopic video camera for rapid robotic surgery development.

    PubMed

    Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C

    2012-01-01

    Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.

  2. AutoCNet: A Python library for sparse multi-image correspondence identification for planetary data

    NASA Astrophysics Data System (ADS)

    Laura, Jason; Rodriguez, Kelvin; Paquette, Adam C.; Dunn, Evin

    2018-01-01

    In this work we describe the AutoCNet library, written in Python, to support the application of computer vision techniques for n-image correspondence identification in remotely sensed planetary images and subsequent bundle adjustment. The library is designed to support exploratory data analysis, algorithm and processing pipeline development, and application at scale in High Performance Computing (HPC) environments for processing large data sets and generating foundational data products. We also present a brief case study illustrating high level usage for the Apollo 15 Metric camera.

  3. Postural Performance and Strategy in the Unipedal Stance of Soccer Players at Different Levels of Competition

    PubMed Central

    Paillard, Thierry; Noé, Frédéric; Rivière, Terence; Marion, Vincent; Montoya, Richard; Dupui, Philippe

    2006-01-01

    Context: Sport training enhances the ability to use somatosensory and otolithic information, which improves postural capabilities. Postural changes are different according to the sport practiced, but few authors have analyzed subjects' postural performances to discriminate the expertise level among highly skilled athletes within a specific discipline. Objective: To compare the postural performance and the postural strategy between soccer players at different levels of competition (national and regional). Design: Repeated measures with 1 between-groups factor (level of competition: national or regional) and 1 within-groups factor (vision: eyes open or eyes closed). Dependent variables were center-of-pressure surface area and velocity; total spectral energy; and percentage of low-, medium-, and high-frequency band. Setting: Sports performance laboratory. Patients or Other Participants: Fifteen national male soccer players (age = 24 ± 3 years, height = 179 ± 5 cm, mass = 72 ± 3 kg) and 15 regional male soccer players (age = 23 ± 3 years, height = 174 ± 4 cm, mass = 68 ± 5 kg) participated in the study. Intervention(s): The subjects performed posturographic tests with eyes open and closed. Main Outcome Measure(s): While subjects performed static and dynamic posturographic tests, we measured the center of foot pressure on a force platform. Spatiotemporal center-of-pressure measurements were used to evaluate the postural performance, and a frequency analysis of the center-of-pressure excursions (fast Fourier transform) was conducted to estimate the postural strategy. Results: Within a laboratory task, national soccer players produced better postural performances than regional players and had a different postural strategy. The national players were more stable than the regional players and used proprioception and vision information differently. Conclusions: In the test conditions specific to playing soccer, level of playing experience influenced postural control performance measures and strategies. PMID:16791302

  4. Postural performance and strategy in the unipedal stance of soccer players at different levels of competition.

    PubMed

    Paillard, Thierry; Noé, Frédéric; Rivière, Terence; Marion, Vincent; Montoya, Richard; Dupui, Philippe

    2006-01-01

    Sport training enhances the ability to use somatosensory and otolithic information, which improves postural capabilities. Postural changes are different according to the sport practiced, but few authors have analyzed subjects' postural performances to discriminate the expertise level among highly skilled athletes within a specific discipline. To compare the postural performance and the postural strategy between soccer players at different levels of competition (national and regional). Repeated measures with 1 between-groups factor (level of competition: national or regional) and 1 within-groups factor (vision: eyes open or eyes closed). Dependent variables were center-of-pressure surface area and velocity; total spectral energy; and percentage of low-, medium-, and high-frequency band. Sports performance laboratory. Fifteen national male soccer players (age = 24 +/- 3 years, height = 179 +/- 5 cm, mass = 72 +/- 3 kg) and 15 regional male soccer players (age = 23 +/- 3 years, height = 174 +/- 4 cm, mass = 68 +/- 5 kg) participated in the study. The subjects performed posturographic tests with eyes open and closed. While subjects performed static and dynamic posturographic tests, we measured the center of foot pressure on a force platform. Spatiotemporal center-of-pressure measurements were used to evaluate the postural performance, and a frequency analysis of the center-of-pressure excursions (fast Fourier transform) was conducted to estimate the postural strategy. Within a laboratory task, national soccer players produced better postural performances than regional players and had a different postural strategy. The national players were more stable than the regional players and used proprioception and vision information differently. In the test conditions specific to playing soccer, level of playing experience influenced postural control performance measures and strategies.

  5. Autonomous Navigation Results from the Mars Exploration Rover (MER) Mission

    NASA Technical Reports Server (NTRS)

    Maimone, Mark; Johnson, Andrew; Cheng, Yang; Willson, Reg; Matthies, Larry H.

    2004-01-01

    In January, 2004, the Mars Exploration Rover (MER) mission landed two rovers, Spirit and Opportunity, on the surface of Mars. Several autonomous navigation capabilities were employed in space for the first time in this mission. ]n the Entry, Descent, and Landing (EDL) phase, both landers used a vision system called the, Descent Image Motion Estimation System (DIMES) to estimate horizontal velocity during the last 2000 meters (m) of descent, by tracking features on the ground with a downlooking camera, in order to control retro-rocket firing to reduce horizontal velocity before impact. During surface operations, the rovers navigate autonomously using stereo vision for local terrain mapping and a local, reactive planning algorithm called Grid-based Estimation of Surface Traversability Applied to Local Terrain (GESTALT) for obstacle avoidance. ]n areas of high slip, stereo vision-based visual odometry has been used to estimate rover motion, As of mid-June, Spirit had traversed 3405 m, of which 1253 m were done autonomously; Opportunity had traversed 1264 m, of which 224 m were autonomous. These results have contributed substantially to the success of the mission and paved the way for increased levels of autonomy in future missions.

  6. Exploration EVA System

    NASA Technical Reports Server (NTRS)

    Kearney, Lara

    2004-01-01

    In January 2004, the President announced a new Vision for Space Exploration. NASA's Office of Exploration Systems has identified Extravehicular Activity (EVA) as a critical capability for supporting the Vision for Space Exploration. EVA is required for all phases of the Vision, both in-space and planetary. Supporting the human outside the protective environment of the vehicle or habitat and allow ing him/her to perform efficient and effective work requires an integrated EVA "System of systems." The EVA System includes EVA suits, airlocks, tools and mobility aids, and human rovers. At the core of the EVA System is the highly technical EVA suit, which is comprised mainly of a life support system and a pressure/environmental protection garment. The EVA suit, in essence, is a miniature spacecraft, which combines together many different sub-systems such as life support, power, communications, avionics, robotics, pressure systems and thermal systems, into a single autonomous unit. Development of a new EVA suit requires technology advancements similar to those required in the development of a new space vehicle. A majority of the technologies necessary to develop advanced EVA systems are currently at a low Technology Readiness Level of 1-3. This is particularly true for the long-pole technologies of the life support system.

  7. Childhood blindness in the context of VISION 2020--the right to sight.

    PubMed Central

    Gilbert, C.; Foster, A.

    2001-01-01

    The major causes of blindness in children vary widely from region to region, being largely determined by socioeconomic development, and the availability of primary health care and eye care services. In high-income countries, lesions of the optic nerve and higher visual pathways predominate as the cause of blindness, while corneal scarring from measles, vitamin A deficiency, the use of harmful traditional eye remedies, and ophthalmia neonatorum are the major causes in low-income countries. Retinopathy of prematurity is an important cause in middle-income countries. Other significant causes in all countries are cataract, congenital abnormalities, and hereditary retinal dystrophies. It is estimated that, in almost half of the children who are blind today, the underlying cause could have been prevented, or the eye condition treated to preserve vision or restore sight. The control of blindness in children is a priority within the World Health Organization's VISION 2020 programme. Strategies need to be region specific, based on activities to prevent blindness in the community--through measles immunization, health education, and control of vitamin A deficiency--and the provision of tertiary-level eye care facilities for conditions that require specialist management. PMID:11285667

  8. Bag-of-visual-ngrams for histopathology image classification

    NASA Astrophysics Data System (ADS)

    López-Monroy, A. Pastor; Montes-y-Gómez, Manuel; Escalante, Hugo Jair; Cruz-Roa, Angel; González, Fabio A.

    2013-11-01

    This paper describes an extension of the Bag-of-Visual-Words (BoVW) representation for image categorization (IC) of histophatology images. This representation is one of the most used approaches in several high-level computer vision tasks. However, the BoVW representation has an important limitation: the disregarding of spatial information among visual words. This information may be useful to capture discriminative visual-patterns in specific computer vision tasks. In order to overcome this problem we propose the use of visual n-grams. N-grams based-representations are very popular in the field of natural language processing (NLP), in particular within text mining and information retrieval. We propose building a codebook of n-grams and then representing images by histograms of visual n-grams. We evaluate our proposal in the challenging task of classifying histopathology images. The novelty of our proposal lies in the fact that we use n-grams as attributes for a classification model (together with visual-words, i.e., 1-grams). This is common practice within NLP, although, to the best of our knowledge, this idea has not been explored yet within computer vision. We report experimental results in a database of histopathology images where our proposed method outperforms the traditional BoVWs formulation.

  9. Use of general medical services among Medicaid patients with severe and persistent mental illness.

    PubMed

    Salsberry, Pamela J; Chipps, Esther; Kennedy, Carol

    2005-04-01

    The aim of this study was to examine patterns of use of general medical services among persons with a severe and persistent mental illness enrolled in Medicaid from 1996 to 1998. A total of 669 persons with a severe and persistent mental illness were identified by using statewide clinical criteria. A three-year database of Medicaid claims was developed to examine service use. The main outcome measures were use of outpatient services for a general medical problem, use of dental and vision services, and use of screening tests for women. Service use was examined by primary psychiatric diagnosis (schizophrenic, affective, paranoid, and anxiety disorders), and analyses controlled for the presence of a chronic medical condition, age, race, and sex. This study found high levels of service use for outpatient services but very low levels for primary and preventive services. Although 78 percent of persons with a schizophrenic disorder had an office-based visit during the three-year period, all persons with an anxiety disorder had such a visit. Sixty-nine percent of persons with a schizophrenic disorder had at least one emergency department visit, whereas 83 percent of those with an anxiety disorder had such a visit. Dental and vision visits and the use of mammograms and pap tests followed the same pattern; persons with a schizophrenic disorder had fewer visits and had less overall use than the other diagnostic groups. The use patterns across the four groups were significantly different in outpatient service use, dental and vision service use, and screening tests for women. Compared with persons with a schizophrenic disorder, those with an anxiety disorder were more likely to have had an office-based visit and to have received vision services, those with a paranoid disorder were more likely to have used dental services or received a mammogram, and those with an affective disorder were more likely to have had a pap test. Although this group of Medicaid patients with severe and persistent mental illness had access to providers, they received an unacceptably low level of preventive care. Use of health services for general medical problems differed somewhat by primary psychiatric illness.

  10. National survey of blindness and low vision in Lebanon

    PubMed Central

    Mansour, A; Kassak, K.; Chaya, M.; Hourani, T.; Sibai, A.; Alameddine, M

    1997-01-01

    AIMS—To survey level of blindness and low vision in Lebanon.
METHODS—A population survey was undertaken in 10 148 individuals to measure the prevalence and identify the causes of blindness in Lebanon.
RESULTS—The prevalence of blindness was 0.6% and that of low vision 3.9%. The major causes of blindness were cataract (41.3%) and uncorrected large refractive error (12.6%).
CONCLUSION—Most causes of blindness in Lebanon can be controlled by various educational and medical programmes.

 PMID:9486035

  11. Visual Estimation of Bacterial Growth Level in Microfluidic Culture Systems.

    PubMed

    Kim, Kyukwang; Kim, Seunggyu; Jeon, Jessie S

    2018-02-03

    Microfluidic devices are an emerging platform for a variety of experiments involving bacterial cell culture, and has advantages including cost and convenience. One inevitable step during bacterial cell culture is the measurement of cell concentration in the channel. The optical density measurement technique is generally used for bacterial growth estimation, but it is not applicable to microfluidic devices due to the small sample volumes in microfluidics. Alternately, cell counting or colony-forming unit methods may be applied, but these do not work in situ; nor do these methods show measurement results immediately. To this end, we present a new vision-based method to estimate the growth level of the bacteria in microfluidic channels. We use Fast Fourier transform (FFT) to detect the frequency level change of the microscopic image, focusing on the fact that the microscopic image becomes rough as the number of cells in the field of view increases, adding high frequencies to the spectrum of the image. Two types of microfluidic devices are used to culture bacteria in liquid and agar gel medium, and time-lapsed images are captured. The images obtained are analyzed using FFT, resulting in an increase in high-frequency noise proportional to the time passed. Furthermore, we apply the developed method in the microfluidic antibiotics susceptibility test by recognizing the regional concentration change of the bacteria that are cultured in the antibiotics gradient. Finally, a deep learning-based data regression is performed on the data obtained by the proposed vision-based method for robust reporting of data.

  12. 78 FR 77777 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-24

    ... vision requirement if the exemptions will provide a level of safety that is equivalent to or greater than... Alex M. Long Charles McDonald Kenneth C. Mead Abdelkhaleq R. Muhammad Eduardo Nunez Michael J... suspension during the 3-year period: Buck J. Barney Charles R. Edwards The following applicant, Victor A...

  13. 76 FR 8278 - Special Conditions: Gulfstream Model GVI Airplane; Enhanced Flight Vision System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-14

    ... detected by infrared sensors can be much different from that detected by natural pilot vision. On a dark... by many imaging infrared systems. On the other hand, contrasting colors in visual wavelengths may be... of the EFVS image and the level of EFVS infrared sensor performance could depend significantly on...

  14. The Implications of a Democratic Vision of Community College Leadership.

    ERIC Educational Resources Information Center

    Gibson-Benninger, Barbara; And Others

    A fundamental challenge facing community college presidents and senior-level staff is to create an environment in which diverse qualities of students and staff make positive contributions to the organization. This requires replacing conceptions of leadership as one person at the top who has power with a vision of democratic leadership which…

  15. Design and Development of a High Speed Sorting System Based on Machine Vision Guiding

    NASA Astrophysics Data System (ADS)

    Zhang, Wenchang; Mei, Jiangping; Ding, Yabin

    In this paper, a vision-based control strategy to perform high speed pick-and-place tasks on automation product line is proposed, and relevant control software is develop. Using Delta robot to control a sucker to grasp disordered objects from one moving conveyer and then place them on the other in order. CCD camera gets one picture every time the conveyer moves a distance of ds. Objects position and shape are got after image processing. Target tracking method based on "Servo motor + synchronous conveyer" is used to fulfill the high speed porting operation real time. Experiments conducted on Delta robot sorting system demonstrate the efficiency and validity of the proposed vision-control strategy.

  16. A computer architecture for intelligent machines

    NASA Technical Reports Server (NTRS)

    Lefebvre, D. R.; Saridis, G. N.

    1992-01-01

    The theory of intelligent machines proposes a hierarchical organization for the functions of an autonomous robot based on the principle of increasing precision with decreasing intelligence. An analytic formulation of this theory using information-theoretic measures of uncertainty for each level of the intelligent machine has been developed. The authors present a computer architecture that implements the lower two levels of the intelligent machine. The architecture supports an event-driven programming paradigm that is independent of the underlying computer architecture and operating system. Execution-level controllers for motion and vision systems are briefly addressed, as well as the Petri net transducer software used to implement coordination-level functions. A case study illustrates how this computer architecture integrates real-time and higher-level control of manipulator and vision systems.

  17. The Artificial Silicon Retina in Retinitis Pigmentosa Patients (An American Ophthalmological Association Thesis)

    PubMed Central

    Chow, Alan Y.; Bittner, Ava K.; Pardue, Machelle T.

    2010-01-01

    Purpose: In a published pilot study, a light-activated microphotodiode-array chip, the artificial silicon retina (ASR), was implanted subretinally in 6 retinitis pigmentosa (RP) patients for up to 18 months. The ASR electrically induced retinal neurotrophic rescue of visual acuity, contrast, and color perception and raised several questions: (1) Would neurotrophic effects develop and persist in additionally implanted RP patients? (2) Could vision in these patients be reliably assessed? (3) Would the ASR be tolerated and function for extended periods? Methods: Four additional RP patients were implanted and observed along with the 6 pilot patients. Of the 10 patients, 6 had vision levels that allowed for more standardized testing and were followed up for 7+ years utilizing ETDRS charts and a 4-alternative forced choice (AFC) Chow grating acuity test (CGAT). A 10-AFC Chow color test (CCT) extended the range of color vision testing. Histologic examination of the eyes of one patient, who died of an unrelated event, was performed. Results: The ASR was well tolerated, and improvement and/or slowing of vision loss occurred in all 6 patients. CGAT extended low vision acuity testing by logMAR 0.6. CCT expanded the range of color vision testing and correlated well with PV-16 (r = 0.77). An ASR recovered from a patient 5 years after implantation showed minor disruption and excellent electrical function. Conclusion: ASR-implanted RP patients experienced prolonged neurotrophic rescue of vision. CGAT and CCT extended the range of acuity and color vision testing in low vision patients. ASR implantation may improve and prolong vision in RP patients. PMID:21212852

  18. Research the mobile phone operation interfaces for vision-impairment.

    PubMed

    Yao, Yen-Ting; Leung, Cherng-Yee

    2012-01-01

    Due to the vision-impaired users commonly having difficulty with mobile-phone function operations and adaption any manufacturer's user interface design, the goals for this research are established for evaluating how to improve for them the function operation convenience and user interfaces of either mobile phones or electronic appliances in the market currently. After applying collecting back 30 effective questionnaires from 30 vision-impairment, the comments have been concluded from this research include: (1) All mobile phone manufactures commonly ignorant of the vision-impairment difficulty with operating mobile phone user interfaces; (2) The vision-impairment preferential with audio alert signals; (3) The vision-impairment incapable of mobile-phone procurement independently unless with assistance from others; (4) Preferential with adding touch-usage interface design by the vision-impairment; in contrast with the least requirement for such functions as braille, enlarging keystroke size and diversifying-function control panel. With exploring the vision-impairment's necessary improvements and obstacles for mobile phone interface operation, this research is established with goals for offering reference possibly applied in electronic appliance design and . Hopefully, the analysis results of this research could be used as data references for designing electronic and high-tech products and promoting more usage convenience for those vision-impaired.

  19. Selection of Phototransduction Genes in Homo sapiens.

    PubMed

    Christopher, Mark; Scheetz, Todd E; Mullins, Robert F; Abràmoff, Michael D

    2013-08-13

    We investigated the evidence of recent positive selection in the human phototransduction system at single nucleotide polymorphism (SNP) and gene level. SNP genotyping data from the International HapMap Project for European, Eastern Asian, and African populations was used to discover differences in haplotype length and allele frequency between these populations. Numeric selection metrics were computed for each SNP and aggregated into gene-level metrics to measure evidence of recent positive selection. The level of recent positive selection in phototransduction genes was evaluated and compared to a set of genes shown previously to be under recent selection, and a set of highly conserved genes as positive and negative controls, respectively. Six of 20 phototransduction genes evaluated had gene-level selection metrics above the 90th percentile: RGS9, GNB1, RHO, PDE6G, GNAT1, and SLC24A1. The selection signal across these genes was found to be of similar magnitude to the positive control genes and much greater than the negative control genes. There is evidence for selective pressure in the genes involved in retinal phototransduction, and traces of this selective pressure can be demonstrated using SNP-level and gene-level metrics of allelic variation. We hypothesize that the selective pressure on these genes was related to their role in low light vision and retinal adaptation to ambient light changes. Uncovering the underlying genetics of evolutionary adaptations in phototransduction not only allows greater understanding of vision and visual diseases, but also the development of patient-specific diagnostic and intervention strategies.

  20. Limits of colour vision in dim light.

    PubMed

    Kelber, Almut; Lind, Olle

    2010-09-01

    Humans and most vertebrates have duplex retinae with multiple cone types for colour vision in bright light, and one single rod type for achromatic vision in dim light. Instead of comparing signals from multiple spectral types of photoreceptors, such species use one highly sensitive receptor type thus improving the signal-to-noise ratio at night. However, the nocturnal hawkmoth Deilephila elpenor, the nocturnal bee Xylocopa tranquebarica and the nocturnal gecko Tarentola chazaliae can discriminate colours at extremely dim light intensities. To be able to do so, they sacrifice spatial and temporal resolution in favour of colour vision. We review what is known about colour vision in dim light, and compare colour vision thresholds with the optical sensitivity of the photoreceptors in selected animal species with lens and compound eyes. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  1. Nocturnality constrains morphological and functional diversity in the eyes of reef fishes.

    PubMed

    Schmitz, Lars; Wainwright, Peter C

    2011-11-19

    Ambient light levels are often considered to drive the evolution of eye form and function. Diel activity pattern is the main mechanism controlling the visual environment of teleost reef fish, with day-active (diurnal) fish active in well-illuminated conditions, whereas night-active (nocturnal) fish cope with dim light. Physiological optics predicts several specific evolutionary responses to dim-light vision that should be reflected in visual performance features of the eye. We analyzed a large comparative dataset on morphological traits of the eyes in 265 species of teleost reef fish in 43 different families. The eye morphology of nocturnal reef teleosts is characterized by a syndrome that indicates better light sensitivity, including large relative eye size, high optical ratio and large, rounded pupils. Improved dim-light image formation comes at the cost of reduced depth of focus and reduction of potential accommodative lens movement. Diurnal teleost reef fish, released from the stringent functional requirements of dim-light vision have much higher morphological and optical diversity than nocturnal species, with large ranges of optical ratio, depth of focus, and lens accommodation. Physical characteristics of the environment are an important factor in the evolution and diversification of the vertebrate eye. Both teleost reef fish and terrestrial amniotes meet the functional requirements of dim-light vision with a similar evolutionary response of morphological and optical modifications. The trade-off between improved dim-light vision and reduced optical diversity may be a key factor in explaining the lower trophic diversity of nocturnal reef teleosts.

  2. A Future Vision for Remotely Piloted Aircraft: Leveraging Interoperability and Networked Operations

    DTIC Science & Technology

    2013-06-21

    over the next 25 years  Balances the effects envisioned in the USAF UAS Flight Plan with the reality of constrained resources and ambitious...theater-level unmanned systems must detect, avoid, or counter threats – operating from permissive to highly contested access in all weather...Rapid Reaction Group II/III SUAS Unit  Light Footprint, Low Cost ISR Option  Networked Autonomous C2 System  Air-Launched SUAS  Common

  3. Toward a Computational Neuropsychology of High-Level Vision.

    DTIC Science & Technology

    1984-08-20

    known as visual agnosia ’ (also called "mindblindness’)l this patient failed to *recognize her nurses, got lost frequently when travelling familiar routes...visual agnosia are not blind: these patients can compare two shapes reliably when Computational neuropsychology 16 both are visible, but they cannot...visually recognize what an object is (although many can recognize objects by touch). This sort of agnosia has been well-documented in the literature (see

  4. Formal System Verification - Extension 2

    DTIC Science & Technology

    2012-08-08

    vision of truly trustworthy systems has been to provide a formally verified microkernel basis. We have previously developed the seL4 microkernel...together with a formal proof (in the theorem prover Isabelle/HOL) of its functional correctness [6]. This means that all the behaviours of the seL4 C...source code are included in the high-level, formal specification of the kernel. This work enabled us to provide further formal guarantees about seL4 , in

  5. MAGTF C2 the Vision for Marine Corps Command and Control

    DTIC Science & Technology

    2008-01-01

    people with low cost high bandwidth capability that was a byproduct of the technological boom over the last decade. As an organization the military needs... military needs to understand that early transformation requires exploiting information technology to reform defense business practices and to create new...tactical, operational, and strategic levels of war. 14 In brief, NCW is not narrowly about technology , but broadly about an emerging military response to

  6. Autonomous Vision-based Rotorcraft Landing and Accurate Aerial Terrain Mapping in an Unknown Environment

    DTIC Science & Technology

    2007-01-22

    requirements for the degree of Master of Science, Plan II. Approval for the Report and Comprehensive Examination: Committee: Professor S. Shankar Sastry...13 2.4 Plans for the high-level planner. . . . . . . . . . . . . . . . . . . . . . . . 14 3.1 Idealized flight for purposes of analyzing...Stamping In order to use the RMFPP algorithm, we must first motion stamp each image, i.e. de - termine the orientation and position of the camera when

  7. High-precision shape representation using a neuromorphic vision sensor with synchronous address-event communication interface

    NASA Astrophysics Data System (ADS)

    Belbachir, A. N.; Hofstätter, M.; Litzenberger, M.; Schön, P.

    2009-10-01

    A synchronous communication interface for neuromorphic temporal contrast vision sensors is described and evaluated in this paper. This interface has been designed for ultra high-speed synchronous arbitration of a temporal contrast image sensors pixels' data. Enabling high-precision timestamping, this system demonstrates its uniqueness for handling peak data rates and preserving the main advantage of the neuromorphic electronic systems, that is high and accurate temporal resolution. Based on a synchronous arbitration concept, the timestamping has a resolution of 100 ns. Both synchronous and (state-of-the-art) asynchronous arbiters have been implemented in a neuromorphic dual-line vision sensor chip in a standard 0.35 µm CMOS process. The performance analysis of both arbiters and the advantages of the synchronous arbitration over asynchronous arbitration in capturing high-speed objects are discussed in detail.

  8. Combined impairments in vision, hearing and cognition are associated with greater levels of functional and communication difficulties than cognitive impairment alone: Analysis of interRAI data for home care and long-term care recipients in Ontario.

    PubMed

    Guthrie, Dawn M; Davidson, Jacob G S; Williams, Nicole; Campos, Jennifer; Hunter, Kathleen; Mick, Paul; Orange, Joseph B; Pichora-Fuller, M Kathleen; Phillips, Natalie A; Savundranayagam, Marie Y; Wittich, Walter

    2018-01-01

    The objective of the current study was to understand the added effects of having a sensory impairment (vision and/or hearing impairment) in combination with cognitive impairment with respect to health-related outcomes among older adults (65+ years old) receiving home care or residing in a long-term care (LTC) facility in Ontario, Canada. Cross-sectional analyses were conducted using existing data collected with one of two interRAI assessments, one for home care (n = 291,824) and one for LTC (n = 110,578). Items in the assessments were used to identify clients with single sensory impairments (e.g., vision only [VI], hearing only [HI]), dual sensory impairment (DSI; i.e., vision and hearing) and those with cognitive impairment (CI). We defined seven mutually exclusive groups based on the presence of single or combined impairments. The rate of people having all three impairments (i.e., CI+DSI) was 21.3% in home care and 29.2% in LTC. Across the seven groups, individuals with all three impairments were the most likely to report loneliness, to have a reduction in social engagement, and to experience reduced independence in their activities of daily living (ADLs) and instrumental ADLs (IADLs). Communication challenges were highly prevalent in this group, at 38.0% in home care and 49.2% in LTC. In both care settings, communication difficulties were more common in the CI+DSI group versus the CI-alone group. The presence of combined sensory and cognitive impairments is high among older adults in these two care settings and having all three impairments is associated with higher rates of negative outcomes than the rates for those having CI alone. There is a rising imperative for all health care professionals to recognize the potential presence of hearing, vision and cognitive impairments in those for whom they provide care, to ensure that basic screening occurs and to use those results to inform care plans.

  9. Combined impairments in vision, hearing and cognition are associated with greater levels of functional and communication difficulties than cognitive impairment alone: Analysis of interRAI data for home care and long-term care recipients in Ontario

    PubMed Central

    2018-01-01

    Objectives The objective of the current study was to understand the added effects of having a sensory impairment (vision and/or hearing impairment) in combination with cognitive impairment with respect to health-related outcomes among older adults (65+ years old) receiving home care or residing in a long-term care (LTC) facility in Ontario, Canada. Methods Cross-sectional analyses were conducted using existing data collected with one of two interRAI assessments, one for home care (n = 291,824) and one for LTC (n = 110,578). Items in the assessments were used to identify clients with single sensory impairments (e.g., vision only [VI], hearing only [HI]), dual sensory impairment (DSI; i.e., vision and hearing) and those with cognitive impairment (CI). We defined seven mutually exclusive groups based on the presence of single or combined impairments. Results The rate of people having all three impairments (i.e., CI+DSI) was 21.3% in home care and 29.2% in LTC. Across the seven groups, individuals with all three impairments were the most likely to report loneliness, to have a reduction in social engagement, and to experience reduced independence in their activities of daily living (ADLs) and instrumental ADLs (IADLs). Communication challenges were highly prevalent in this group, at 38.0% in home care and 49.2% in LTC. In both care settings, communication difficulties were more common in the CI+DSI group versus the CI-alone group. Conclusions The presence of combined sensory and cognitive impairments is high among older adults in these two care settings and having all three impairments is associated with higher rates of negative outcomes than the rates for those having CI alone. There is a rising imperative for all health care professionals to recognize the potential presence of hearing, vision and cognitive impairments in those for whom they provide care, to ensure that basic screening occurs and to use those results to inform care plans. PMID:29447253

  10. Insect vision as model for machine vision

    NASA Astrophysics Data System (ADS)

    Osorio, D.; Sobey, Peter J.

    1992-11-01

    The neural architecture, neurophysiology and behavioral abilities of insect vision are described, and compared with that of mammals. Insects have a hardwired neural architecture of highly differentiated neurons, quite different from the cerebral cortex, yet their behavioral abilities are in important respects similar to those of mammals. These observations challenge the view that the key to the power of biological neural computation is distributed processing by a plastic, highly interconnected, network of individually undifferentiated and unreliable neurons that has been a dominant picture of biological computation since Pitts and McCulloch's seminal work in the 1940's.

  11. Ezekiel's vision: Visual evidence of Sterno-Etrussia geomagnetic excursion?

    NASA Astrophysics Data System (ADS)

    Raspopov, Oleg M.; Dergachev, Valentin A.; Goos'kova, Elena G.

    In the Eos article,“Ezekiel and the Northern Lights: Biblical Aurora Seems Plausible” (16 April 2002), Siscoe et al. presented arguments showing that coronal auroras can occur at low latitudes under the condition of increased geomagnetic dipole field strength. From this standpoint, they give an interpretation of the “reported” Ezekiel's vision (the Bible's Book of Ezekiel in the Old Testament). The site of the Ezekiel's vision was about 100 km south of Babylon (latitude ˜32° N, longitude ˜5°E), and the date of the vision was around 593 B.C. Auroral specialists believe that Ezekiel's vision was inspired by a very strong magnetic storm accompanied by coronal auroras at low latitudes. However, as justly noted by Siscoe et al. [2002],to adopt this interpretation, several questions should be answered. Can auroras be seen at the latitude where Ezekiel reportedly was? More important, can they reach a coronal stage of development, which is what the vision requires? Was the tilt of the dipole axis favorable? Was the general level of solar activity favorable? The principal question is, no doubt, the second one.

  12. Ethical, environmental and social issues for machine vision in manufacturing industry

    NASA Astrophysics Data System (ADS)

    Batchelor, Bruce G.; Whelan, Paul F.

    1995-10-01

    Some of the ethical, environmental and social issues relating to the design and use of machine vision systems in manufacturing industry are highlighted. The authors' aim is to emphasize some of the more important issues, and raise general awareness of the need to consider the potential advantages and hazards of machine vision technology. However, in a short article like this, it is impossible to cover the subject comprehensively. This paper should therefore be seen as a discussion document, which it is hoped will provoke more detailed consideration of these very important issues. It follows from an article presented at last year's workshop. Five major topics are discussed: (1) The impact of machine vision systems on the environment; (2) The implications of machine vision for product and factory safety, the health and well-being of employees; (3) The importance of intellectual integrity in a field requiring a careful balance of advanced ideas and technologies; (4) Commercial and managerial integrity; and (5) The impact of machine visions technology on employment prospects, particularly for people with low skill levels.

  13. Scalable Photogrammetric Motion Capture System "mosca": Development and Application

    NASA Astrophysics Data System (ADS)

    Knyaz, V. A.

    2015-05-01

    Wide variety of applications (from industrial to entertainment) has a need for reliable and accurate 3D information about motion of an object and its parts. Very often the process of movement is rather fast as in cases of vehicle movement, sport biomechanics, animation of cartoon characters. Motion capture systems based on different physical principles are used for these purposes. The great potential for obtaining high accuracy and high degree of automation has vision-based system due to progress in image processing and analysis. Scalable inexpensive motion capture system is developed as a convenient and flexible tool for solving various tasks requiring 3D motion analysis. It is based on photogrammetric techniques of 3D measurements and provides high speed image acquisition, high accuracy of 3D measurements and highly automated processing of captured data. Depending on the application the system can be easily modified for different working areas from 100 mm to 10 m. The developed motion capture system uses from 2 to 4 technical vision cameras for video sequences of object motion acquisition. All cameras work in synchronization mode at frame rate up to 100 frames per second under the control of personal computer providing the possibility for accurate calculation of 3D coordinates of interest points. The system was used for a set of different applications fields and demonstrated high accuracy and high level of automation.

  14. Relationship of cataract symptoms of preoperative patients and vision-related quality of life.

    PubMed

    Lee, Jae Eun; Fos, Peter J; Sung, Jung Hye; Amy, Brian W; Zuniga, Miguel A; Lee, Won Jae; Kim, Jae Chang

    2005-10-01

    This study was conducted in an attempt to describe the status of cataract symptoms of preoperative cataract patients, as well as to determine the relationship between cataract symptom and vision-related quality of life measures. A cross-sectional study design was used. Study subjects were selected using non-probabilistic methods. The study sample consisted of 132 patients scheduled for cataract surgery in one eye. Information was obtained from study subjects by conducting face-to-face interviews. Study subjects were adult cataract patients at Samsung and Kunyang General Hospitals in Seoul, Korea, and Tulane University Hospital and Clinics in New Orleans, Louisiana, United States of America. Degree to which study subjects were "bothered" by cataract symptoms was measured by using the 5-item Cataract Symptom Scores (CSS). The number of symptoms, highest scored symptom among the five, number of symptoms extremely bothering, and the mean of cataract symptom score were created based on the CSS measure. Vision-related quality of life was assessed by using the Visual Function 14 Items (VF-14) and Global Measure of Vision (GMV) for trouble and satisfaction. The symptoms "blurry vision" and "worsening of vision" were most frequently reported. The symptom "colors looking different" was rarely reported among preoperative cataract patients. The degree to which study subjects were bothered by "blurry vision" and "seeing glare, halo, or rings" was highly associated with visual function, visual trouble, and visual satisfaction. Multiple regression analysis revealed that the newly developed cataract symptom-related scales, as well as total amount of degree to which study subjects were "bothered" by symptoms were highly related to vision-related quality of life measures. These relationships were persistent after controlling for major socio-demographic variables. The results indicate that cataract symptoms are highly associated with vision-related quality of life. The results also suggest that the number of symptoms, highest scored symptom among the five, number of symptoms extremely bothering, and the mean cataract symptom scores should be considered an important cataract symptom-related scale when analyzing quality of life, including cataract symptom.

  15. Image registration algorithm for high-voltage electric power live line working robot based on binocular vision

    NASA Astrophysics Data System (ADS)

    Li, Chengqi; Ren, Zhigang; Yang, Bo; An, Qinghao; Yu, Xiangru; Li, Jinping

    2017-12-01

    In the process of dismounting and assembling the drop switch for the high-voltage electric power live line working (EPL2W) robot, one of the key problems is the precision of positioning for manipulators, gripper and the bolts used to fix drop switch. To solve it, we study the binocular vision system theory of the robot and the characteristic of dismounting and assembling drop switch. We propose a coarse-to-fine image registration algorithm based on image correlation, which can improve the positioning precision of manipulators and bolt significantly. The algorithm performs the following three steps: firstly, the target points are marked respectively in the right and left visions, and then the system judges whether the target point in right vision can satisfy the lowest registration accuracy by using the similarity of target points' backgrounds in right and left visions, this is a typical coarse-to-fine strategy; secondly, the system calculates the epipolar line, and then the regional sequence existing matching points is generated according to neighborhood of epipolar line, the optimal matching image is confirmed by calculating the similarity between template image in left vision and the region in regional sequence according to correlation matching; finally, the precise coordinates of target points in right and left visions are calculated according to the optimal matching image. The experiment results indicate that the positioning accuracy of image coordinate is within 2 pixels, the positioning accuracy in the world coordinate system is within 3 mm, the positioning accuracy of binocular vision satisfies the requirement dismounting and assembling the drop switch.

  16. Development of a Wireless Computer Vision Instrument to Detect Biotic Stress in Wheat

    PubMed Central

    Casanova, Joaquin J.; O'Shaughnessy, Susan A.; Evett, Steven R.; Rush, Charles M.

    2014-01-01

    Knowledge of crop abiotic and biotic stress is important for optimal irrigation management. While spectral reflectance and infrared thermometry provide a means to quantify crop stress remotely, these measurements can be cumbersome. Computer vision offers an inexpensive way to remotely detect crop stress independent of vegetation cover. This paper presents a technique using computer vision to detect disease stress in wheat. Digital images of differentially stressed wheat were segmented into soil and vegetation pixels using expectation maximization (EM). In the first season, the algorithm to segment vegetation from soil and distinguish between healthy and stressed wheat was developed and tested using digital images taken in the field and later processed on a desktop computer. In the second season, a wireless camera with near real-time computer vision capabilities was tested in conjunction with the conventional camera and desktop computer. For wheat irrigated at different levels and inoculated with wheat streak mosaic virus (WSMV), vegetation hue determined by the EM algorithm showed significant effects from irrigation level and infection. Unstressed wheat had a higher hue (118.32) than stressed wheat (111.34). In the second season, the hue and cover measured by the wireless computer vision sensor showed significant effects from infection (p = 0.0014), as did the conventional camera (p < 0.0001). Vegetation hue obtained through a wireless computer vision system in this study is a viable option for determining biotic crop stress in irrigation scheduling. Such a low-cost system could be suitable for use in the field in automated irrigation scheduling applications. PMID:25251410

  17. Facial recognition using simulated prosthetic pixelized vision.

    PubMed

    Thompson, Robert W; Barnett, G David; Humayun, Mark S; Dagnelie, Gislin

    2003-11-01

    To evaluate a model of simulated pixelized prosthetic vision using noncontiguous circular phosphenes, to test the effects of phosphene and grid parameters on facial recognition. A video headset was used to view a reference set of four faces, followed by a partially averted image of one of those faces viewed through a square pixelizing grid that contained 10x10 to 32x32 dots separated by gaps. The grid size, dot size, gap width, dot dropout rate, and gray-scale resolution were varied separately about a standard test condition, for a total of 16 conditions. All tests were first performed at 99% contrast and then repeated at 12.5% contrast. Discrimination speed and performance were influenced by all stimulus parameters. The subjects achieved highly significant facial recognition accuracy for all high-contrast tests except for grids with 70% random dot dropout and two gray levels. In low-contrast tests, significant facial recognition accuracy was achieved for all but the most adverse grid parameters: total grid area less than 17% of the target image, 70% dropout, four or fewer gray levels, and a gap of 40.5 arcmin. For difficult test conditions, a pronounced learning effect was noticed during high-contrast trials, and a more subtle practice effect on timing was evident during subsequent low-contrast trials. These findings suggest that reliable face recognition with crude pixelized grids can be learned and may be possible, even with a crude visual prosthesis.

  18. [Incorporation and adaptation of the postmodern belief system].

    PubMed

    Garzón Pérez, Adela

    2012-01-01

    Every society develops a particular system of beliefs that summarizes its vision of socio-political organization, culture and interpersonal relationships. Each of these three basic dimensions has different forms, depending on the spatial and temporal context of societies. The belief system of the service societies is characterized by a democratic vision of social and political organization, rejection of radical social changes and high levels of interpersonal trust. This paper empirically examines the incorporation and adaptation of the postmodern belief system in a sample of university students. The participants belong to a country that is slowly integrating into the service societies. We used a scale of postmodernity to analyze the incorporation of the postmodern belief system. The results indicate that there is a peculiar combination of the three basic dimensions of the postmodern belief system, where the postmodern conceptions of culture and social relationships have lower acceptance.

  19. Human vision is attuned to the diffuseness of natural light

    PubMed Central

    Morgenstern, Yaniv; Geisler, Wilson S.; Murray, Richard F.

    2014-01-01

    All images are highly ambiguous, and to perceive 3-D scenes, the human visual system relies on assumptions about what lighting conditions are most probable. Here we show that human observers' assumptions about lighting diffuseness are well matched to the diffuseness of lighting in real-world scenes. We use a novel multidirectional photometer to measure lighting in hundreds of environments, and we find that the diffuseness of natural lighting falls in the same range as previous psychophysical estimates of the visual system's assumptions about diffuseness. We also find that natural lighting is typically directional enough to override human observers' assumption that light comes from above. Furthermore, we find that, although human performance on some tasks is worse in diffuse light, this can be largely accounted for by intrinsic task difficulty. These findings suggest that human vision is attuned to the diffuseness levels of natural lighting conditions. PMID:25139864

  20. Opportunistic infections of the retina in patients with aquaporin-4 antibody disease.

    PubMed

    George, Jithin S; Leite, Maria Isabel; Kitley, Joanna L; Jones, Nicola; Cortes, Nicholas; Donati, Matthew; Matthews, Bethan Non; Calladine, Daniel; Hillier, Charles; Yusuf, Imran H; Munneke, Robert; Patel, Chetan K; Palace, Jacqueline A; Elston, John S

    2014-11-01

    Patients with neuromyelitis optica who have aquaporin-4 antibodies are being identified and receiving immunosuppressant treatment earlier and more aggressively as a result of increasing awareness of the importance of preventing relapses responsible for the high morbidity and mortality associated with the disease. To our knowledge, opportunistic retinal infection in patients with aquaporin-4 antibodies who are receiving immunosuppressants has not been reported to date. We describe 2 patients with aquaporin-4 antibodies who were receiving conventional doses of first-line immunosuppressive therapy. Both patients presented with vision loss that was initially thought to be optic neuritis attacks. The subsequent diagnoses were ocular toxoplasmosis and cytomegalovirus retinitis. Retinal opportunistic infections can occur in patients with aquaporin-4 antibodies who are receiving relatively low levels of immunosuppression, may mimic optic neuritis, and are a potentially reversible cause of vision loss when treated promptly.

  1. Processing of Lunar Soil Simulant for Space Exploration Applications

    NASA Technical Reports Server (NTRS)

    Sen, Subhayu; Ray, Chandra S.; Reddy, Ramana

    2005-01-01

    NASA's long-term vision for space exploration includes developing human habitats and conducting scientific investigations on planetary bodies, especially on Moon and Mars. To reduce the level of up-mass processing and utilization of planetary in-situ resources is recognized as an important element of this vision. Within this scope and context, we have undertaken a general effort aimed primarily at extracting and refining metals, developing glass, glass-ceramic, or traditional ceramic type materials using lunar soil simulants. In this paper we will present preliminary results on our effort on carbothermal reduction of oxides for elemental extraction and zone refining for obtaining high purity metals. In additions we will demonstrate the possibility of developing glasses from lunar soil simulant for fixing nuclear waste from potential nuclear power generators on planetary bodies. Compositional analysis, x-ray diffraction patterns and differential thermal analysis of processed samples will be presented.

  2. Model-based object classification using unification grammars and abstract representations

    NASA Astrophysics Data System (ADS)

    Liburdy, Kathleen A.; Schalkoff, Robert J.

    1993-04-01

    The design and implementation of a high level computer vision system which performs object classification is described. General object labelling and functional analysis require models of classes which display a wide range of geometric variations. A large representational gap exists between abstract criteria such as `graspable' and current geometric image descriptions. The vision system developed and described in this work addresses this problem and implements solutions based on a fusion of semantics, unification, and formal language theory. Object models are represented using unification grammars, which provide a framework for the integration of structure and semantics. A methodology for the derivation of symbolic image descriptions capable of interacting with the grammar-based models is described and implemented. A unification-based parser developed for this system achieves object classification by determining if the symbolic image description can be unified with the abstract criteria of an object model. Future research directions are indicated.

  3. Effects of self-reported hearing or vision impairment on depressive symptoms: a population-based longitudinal study.

    PubMed

    Han, J H; Lee, H J; Jung, J; Park, E-C

    2018-02-08

    The aims of this study were to investigate the effects of either hearing, vision or dual sensory impairment on depressive symptoms and to identify subgroups that are vulnerable and significantly affected. Data from the 2006-2014 Korean Longitudinal Study of Aging (KLoSA) were used and a total of 5832 individuals were included in this study. Depressive symptoms were assessed using the Center for Epidemiologic Studies Depression (CES-D10) scale. Sensory impairment was assessed according to the levels of self-reported hearing or vision, which were categorised as either good (excellent, very good or good) or poor (fair or poor). The changes in hearing or vision from records of previous survey were investigated. Changes from good to poor, which indicates new onset, were defined as hearing impairment or vision impairment. Interactions of changes in hearing and vision were considered in the analysis. Dual sensory impairment was indicated when hearing impairment and vision impairment both developed at the same time. Demographic, socioeconomic and health-related factors were considered as potential confounders and were adjusted for in the generalised estimating equation model. Individuals with hearing impairment demonstrated significantly more severe depressive symptoms [β = 0.434, standard errors (s.e.) = 0.097, p < 0.001] than those who had good hearing. Those with vision impairment also showed significantly elevated depressive symptoms (β = 0.253, s.e. = 0.058, p < 0.001) than those with good vision. When the interactions between hearing and vision were considered, participants with dual sensory impairment showed significantly more severe depressive symptoms (β = 0.768, s.e. = 0.197, p < 0.001) than those with good hearing and vision. The effect of a single and dual sensory impairment on depressive symptoms was significant in both sexes and across age groups, except for vision impairment in male participants. Hearing, vision and dual sensory impairment are significantly associated with depressive symptoms. Our results suggest that treatment or rehabilitation of either hearing or vision impairment would help prevent depression.

  4. Mission, Vision, Values, and Goals: An Exploration of Key Organizational Statements and Daily Practice in Schools

    ERIC Educational Resources Information Center

    Gurley, D. Keith; Peters, Gary B.; Collins, Loucrecia; Fifolt, Matthew

    2015-01-01

    This article reports findings from a study of graduate level, educational leadership students' familiarity with shared mission, vision, values, and goals statements and the perceived impact these concepts have on their practice as leaders and teachers in schools. The study is primarily qualitative and uses content analysis of responses to…

  5. VISIONS At-Sea Telepresence (VAST): Educating in Real Time, Seafloor to Shore

    NASA Astrophysics Data System (ADS)

    Sautter, L. R.; Fundis, A. T.; Kelley, D. S.; Delaney, J. R.; McNichol, E.; Stoermer, M.; Glenn, S. M.

    2012-12-01

    The University of Washington (UW) has recently led the VISIONS 2011 and 2012 cruises aboard the R/V Thompson to Axial Seamount on the Juan de Fuca Ridge, part of the NSF Ocean Observatory Initiative. During each cruise the VISIONS At-Sea Telepresence, or VAST Program was piloted, consisting of several live 30-60 minute shipboard broadcasts highlighted by streaming live HD video from the ROV ROPOS documenting investigations of the seamount's hydrothermal vents and recent lava flows. Broadcasts also included short lectures and pre-taped documentaries and seafloor video narrated live by shipboard scientists and students. Pilot audiences at UW, the College of Charleston and Rutgers University included undergraduate marine geology, oceanography and education students, high school students, graduate students and teachers. Multiple public audiences were also recipients of VAST programming, and all broadcasts were viewable in standard definition to any web users. Question/answer interactivity via Twitter and Skype were promoted throughout the broadcasts. To supplement live broadcasts with additional content, a VAST Program website was created on UW's Interactive Oceans site, providing a wealth of hyperlinked online resources covering six program themes, as well as a college-level online laboratory exercise, "Characterizing Lava Flow Morphologies." The online resources are primarily suited to inform a high school and older audience, and thus serves to reach a vast audience. The VAST Program was very successful at engaging and educating both formal and informal audiences. Preliminary VAST results documented by user surveys will be presented.

  6. External Vision Systems (XVS) Proof-of-Concept Flight Test Evaluation

    NASA Technical Reports Server (NTRS)

    Shelton, Kevin J.; Williams, Steven P.; Kramer, Lynda J.; Arthur, Jarvis J.; Prinzel, Lawrence, III; Bailey, Randall E.

    2014-01-01

    NASA's Fundamental Aeronautics Program, High Speed Project is performing research, development, test and evaluation of flight deck and related technologies to support future low-boom, supersonic configurations (without forward-facing windows) by use of an eXternal Vision System (XVS). The challenge of XVS is to determine a combination of sensor and display technologies which can provide an equivalent level of safety and performance to that provided by forward-facing windows in today's aircraft. This flight test was conducted with the goal of obtaining performance data on see-and-avoid and see-to-follow traffic using a proof-of-concept XVS design in actual flight conditions. Six data collection flights were flown in four traffic scenarios against two different sized participating traffic aircraft. This test utilized a 3x1 array of High Definition (HD) cameras, with a fixed forward field-of-view, mounted on NASA Langley's UC-12 test aircraft. Test scenarios, with participating NASA aircraft serving as traffic, were presented to two evaluation pilots per flight - one using the proof-of-concept (POC) XVS and the other looking out the forward windows. The camera images were presented on the XVS display in the aft cabin with Head-Up Display (HUD)-like flight symbology overlaying the real-time imagery. The test generated XVS performance data, including comparisons to natural vision, and post-run subjective acceptability data were also collected. This paper discusses the flight test activities, its operational challenges, and summarizes the findings to date.

  7. A neural network based artificial vision system for licence plate recognition.

    PubMed

    Draghici, S

    1997-02-01

    This paper presents a neural network based artificial vision system able to analyze the image of a car given by a camera, locate the registration plate and recognize the registration number of the car. The paper describes in detail various practical problems encountered in implementing this particular application and the solutions used to solve them. The main features of the system presented are: controlled stability-plasticity behavior, controlled reliability threshold, both off-line and on-line learning, self assessment of the output reliability and high reliability based on high level multiple feedback. The system has been designed using a modular approach. Sub-modules can be upgraded and/or substituted independently, thus making the system potentially suitable in a large variety of vision applications. The OCR engine was designed as an interchangeable plug-in module. This allows the user to choose an OCR engine which is suited to the particular application and to upgrade it easily in the future. At present, there are several versions of this OCR engine. One of them is based on a fully connected feedforward artificial neural network with sigmoidal activation functions. This network can be trained with various training algorithms such as error backpropagation. An alternative OCR engine is based on the constraint based decomposition (CBD) training architecture. The system has showed the following performances (on average) on real-world data: successful plate location and segmentation about 99%, successful character recognition about 98% and successful recognition of complete registration plates about 80%.

  8. Parametric dense stereovision implementation on a system-on chip (SoC).

    PubMed

    Gardel, Alfredo; Montejo, Pablo; García, Jorge; Bravo, Ignacio; Lázaro, José L

    2012-01-01

    This paper proposes a novel hardware implementation of a dense recovery of stereovision 3D measurements. Traditionally 3D stereo systems have imposed the maximum number of stereo correspondences, introducing a large restriction on artificial vision algorithms. The proposed system-on-chip (SoC) provides great performance and efficiency, with a scalable architecture available for many different situations, addressing real time processing of stereo image flow. Using double buffering techniques properly combined with pipelined processing, the use of reconfigurable hardware achieves a parametrisable SoC which gives the designer the opportunity to decide its right dimension and features. The proposed architecture does not need any external memory because the processing is done as image flow arrives. Our SoC provides 3D data directly without the storage of whole stereo images. Our goal is to obtain high processing speed while maintaining the accuracy of 3D data using minimum resources. Configurable parameters may be controlled by later/parallel stages of the vision algorithm executed on an embedded processor. Considering hardware FPGA clock of 100 MHz, image flows up to 50 frames per second (fps) of dense stereo maps of more than 30,000 depth points could be obtained considering 2 Mpix images, with a minimum initial latency. The implementation of computer vision algorithms on reconfigurable hardware, explicitly low level processing, opens up the prospect of its use in autonomous systems, and they can act as a coprocessor to reconstruct 3D images with high density information in real time.

  9. Enhancing Advocacy for Eye Care at National Levels: What Steps to Take for the Next Decade?

    PubMed Central

    Rabiu, Muhammad Mansur; Al Rajhi, Abdulaziz; Qureshi, Mohammed Babar; Gersbeck, Jennifer

    2012-01-01

    The global initiative for the elimination of avoidable blindness by the year 2020-(VISION 2020- The Right to Sight), established in 1999, is a partnership of nongovernmental organizations (NGOs), governments, bilateral organizations, corporate bodies and the World Health Organization. The goal is to eliminate the major causes of avoidable blindness by the year 2020. Significant progress has been made in the last decade. For example, the adoption of three major World Health Assembly resolutions (WHA 56.26, 59.25 and 62.1) requesting governments to increase support and funding for the prevention of blindness and eye care. Additionally, the approval of the VISION 2020 declaration, development of plans and establishment of prevention of blindness committees and a designation of a coordinator by most participating countries represent other major achievements. Furthermore there has been increased political and professional commitment to the prevention of visual impairment and an increase in the provision of high-quality, sustainable eye care. Most of these achievements have been attributed to the advocacy efforts of VISION 2020 at the international level. The full success of this global initiative will likely depend on the extent to which the WHA resolutions are implemented in each country. However, most ratifying countries have not moved forward with implementation of these resolutions. To date, only few countries have shown consistent government support and funding for eye care pursuant to the resolutions. One of the main reasons for this may be inadequate and inappropriate advocacy for eye care at the national level. As such it is believed that the success of VISION 2020 in the next decade will depend on intense advocacy campaigns at national levels. This review identified some of the countries and health programs that have had fruitful advocacy efforts, to determine the factors that dictated success. The review highlights the factors of successful advocacy in two countries (Australia and Pakistan) that secured continued government support. The review further explores the achievements of the HIV/AIDs control network advocacy in securing global and national government support. Common factors for successful advocacy at the national level were identified to include generation of evidence data and effective utilization of the data with an appropriate forum and media to develop a credible relationship with prominent decision makers. Aligning eye care programming to the broad health and development agendas was a useful advocacy effort. Also a broad all-encompassing coalition of all stakeholders provides a solid platform for effective and persistent advocacy for government support of eye care. PMID:22346118

  10. Computer vision for driver assistance systems

    NASA Astrophysics Data System (ADS)

    Handmann, Uwe; Kalinke, Thomas; Tzomakas, Christos; Werner, Martin; von Seelen, Werner

    1998-07-01

    Systems for automated image analysis are useful for a variety of tasks and their importance is still increasing due to technological advances and an increase of social acceptance. Especially in the field of driver assistance systems the progress in science has reached a level of high performance. Fully or partly autonomously guided vehicles, particularly for road-based traffic, pose high demands on the development of reliable algorithms due to the conditions imposed by natural environments. At the Institut fur Neuroinformatik, methods for analyzing driving relevant scenes by computer vision are developed in cooperation with several partners from the automobile industry. We introduce a system which extracts the important information from an image taken by a CCD camera installed at the rear view mirror in a car. The approach consists of a sequential and a parallel sensor and information processing. Three main tasks namely the initial segmentation (object detection), the object tracking and the object classification are realized by integration in the sequential branch and by fusion in the parallel branch. The main gain of this approach is given by the integrative coupling of different algorithms providing partly redundant information.

  11. Information theory analysis of sensor-array imaging systems for computer vision

    NASA Technical Reports Server (NTRS)

    Huck, F. O.; Fales, C. L.; Park, S. K.; Samms, R. W.; Self, M. O.

    1983-01-01

    Information theory is used to assess the performance of sensor-array imaging systems, with emphasis on the performance obtained with image-plane signal processing. By electronically controlling the spatial response of the imaging system, as suggested by the mechanism of human vision, it is possible to trade-off edge enhancement for sensitivity, increase dynamic range, and reduce data transmission. Computational results show that: signal information density varies little with large variations in the statistical properties of random radiance fields; most information (generally about 85 to 95 percent) is contained in the signal intensity transitions rather than levels; and performance is optimized when the OTF of the imaging system is nearly limited to the sampling passband to minimize aliasing at the cost of blurring, and the SNR is very high to permit the retrieval of small spatial detail from the extensively blurred signal. Shading the lens aperture transmittance to increase depth of field and using a regular hexagonal sensor-array instead of square lattice to decrease sensitivity to edge orientation also improves the signal information density up to about 30 percent at high SNRs.

  12. Vision Systems with the Human in the Loop

    NASA Astrophysics Data System (ADS)

    Bauckhage, Christian; Hanheide, Marc; Wrede, Sebastian; Käster, Thomas; Pfeiffer, Michael; Sagerer, Gerhard

    2005-12-01

    The emerging cognitive vision paradigm deals with vision systems that apply machine learning and automatic reasoning in order to learn from what they perceive. Cognitive vision systems can rate the relevance and consistency of newly acquired knowledge, they can adapt to their environment and thus will exhibit high robustness. This contribution presents vision systems that aim at flexibility and robustness. One is tailored for content-based image retrieval, the others are cognitive vision systems that constitute prototypes of visual active memories which evaluate, gather, and integrate contextual knowledge for visual analysis. All three systems are designed to interact with human users. After we will have discussed adaptive content-based image retrieval and object and action recognition in an office environment, the issue of assessing cognitive systems will be raised. Experiences from psychologically evaluated human-machine interactions will be reported and the promising potential of psychologically-based usability experiments will be stressed.

  13. Integrated Imaging and Vision Techniques for Industrial Inspection: A Special Issue on Machine Vision and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Zheng; Ukida, H.; Ramuhalli, Pradeep

    2010-06-05

    Imaging- and vision-based techniques play an important role in industrial inspection. The sophistication of the techniques assures high- quality performance of the manufacturing process through precise positioning, online monitoring, and real-time classification. Advanced systems incorporating multiple imaging and/or vision modalities provide robust solutions to complex situations and problems in industrial applications. A diverse range of industries, including aerospace, automotive, electronics, pharmaceutical, biomedical, semiconductor, and food/beverage, etc., have benefited from recent advances in multi-modal imaging, data fusion, and computer vision technologies. Many of the open problems in this context are in the general area of image analysis methodologies (preferably in anmore » automated fashion). This editorial article introduces a special issue of this journal highlighting recent advances and demonstrating the successful applications of integrated imaging and vision technologies in industrial inspection.« less

  14. The High Schools English Learners Need. Policy Paper

    ERIC Educational Resources Information Center

    Gold, Norm,

    2006-01-01

    Despite the best efforts of thousands of dedicated people, California's secondary schools are failing to adequately educate the majority of the state's English language learners (ELs). The purpose of this paper is to present a vision for high schools that will promote greater success for these students. This vision is based on Norm Gold's 30 years…

  15. Machine Learning, deep learning and optimization in computer vision

    NASA Astrophysics Data System (ADS)

    Canu, Stéphane

    2017-03-01

    As quoted in the Large Scale Computer Vision Systems NIPS workshop, computer vision is a mature field with a long tradition of research, but recent advances in machine learning, deep learning, representation learning and optimization have provided models with new capabilities to better understand visual content. The presentation will go through these new developments in machine learning covering basic motivations, ideas, models and optimization in deep learning for computer vision, identifying challenges and opportunities. It will focus on issues related with large scale learning that is: high dimensional features, large variety of visual classes, and large number of examples.

  16. Advanced helmet vision system (AHVS) integrated night vision helmet mounted display (HMD)

    NASA Astrophysics Data System (ADS)

    Ashcraft, Todd W.; Atac, Robert

    2012-06-01

    Gentex Corporation, under contract to Naval Air Systems Command (AIR 4.0T), designed the Advanced Helmet Vision System to provide aircrew with 24-hour, visor-projected binocular night vision and HMD capability. AHVS integrates numerous key technologies, including high brightness Light Emitting Diode (LED)-based digital light engines, advanced lightweight optical materials and manufacturing processes, and innovations in graphics processing software. This paper reviews the current status of miniaturization and integration with the latest two-part Gentex modular helmet, highlights the lessons learned from previous AHVS phases, and discusses plans for qualification and flight testing.

  17. Some examples of image warping for low vision prosthesis

    NASA Technical Reports Server (NTRS)

    Juday, Richard D.; Loshin, David S.

    1988-01-01

    NASA has developed an image processor, the Programmable Remapper, for certain functions in machine vision. The Remapper performs a highly arbitrary geometric warping of an image at video rate. It might ultimately be shrunk to a size and cost that could allow its use in a low-vision prosthesis. Coordinate warpings have been developed for retinitis pigmentosa (tunnel vision) and for maculapathy (loss of central field) that are intended to make best use of the patient's remaining viable retina. The rationales and mathematics are presented for some warpings that we will try in clinical studies using the Remapper's prototype.

  18. A High-Speed Target-Free Vision-Based Sensor for Bus Rapid Transit Viaduct Vibration Measurements Using CMT and ORB Algorithms.

    PubMed

    Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan

    2017-06-06

    Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable.

  19. A High-Speed Target-Free Vision-Based Sensor for Bus Rapid Transit Viaduct Vibration Measurements Using CMT and ORB Algorithms

    PubMed Central

    Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan

    2017-01-01

    Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable. PMID:28587275

  20. MMW radar enhanced vision systems: the Helicopter Autonomous Landing System (HALS) and Radar-Enhanced Vision System (REVS) are rotary and fixed wing enhanced flight vision systems that enable safe flight operations in degraded visual environments

    NASA Astrophysics Data System (ADS)

    Cross, Jack; Schneider, John; Cariani, Pete

    2013-05-01

    Sierra Nevada Corporation (SNC) has developed rotary and fixed wing millimeter wave radar enhanced vision systems. The Helicopter Autonomous Landing System (HALS) is a rotary-wing enhanced vision system that enables multi-ship landing, takeoff, and enroute flight in Degraded Visual Environments (DVE). HALS has been successfully flight tested in a variety of scenarios, from brown-out DVE landings, to enroute flight over mountainous terrain, to wire/cable detection during low-level flight. The Radar Enhanced Vision Systems (REVS) is a fixed-wing Enhanced Flight Vision System (EFVS) undergoing prototype development testing. Both systems are based on a fast-scanning, threedimensional 94 GHz radar that produces real-time terrain and obstacle imagery. The radar imagery is fused with synthetic imagery of the surrounding terrain to form a long-range, wide field-of-view display. A symbology overlay is added to provide aircraft state information and, for HALS, approach and landing command guidance cuing. The combination of see-through imagery and symbology provides the key information a pilot needs to perform safe flight operations in DVE conditions. This paper discusses the HALS and REVS systems and technology, presents imagery, and summarizes the recent flight test results.

  1. Vision-Aided RAIM: A New Method for GPS Integrity Monitoring in Approach and Landing Phase

    PubMed Central

    Fu, Li; Zhang, Jun; Li, Rui; Cao, Xianbin; Wang, Jinling

    2015-01-01

    In the 1980s, Global Positioning System (GPS) receiver autonomous integrity monitoring (RAIM) was proposed to provide the integrity of a navigation system by checking the consistency of GPS measurements. However, during the approach and landing phase of a flight path, where there is often low GPS visibility conditions, the performance of the existing RAIM method may not meet the stringent aviation requirements for availability and integrity due to insufficient observations. To solve this problem, a new RAIM method, named vision-aided RAIM (VA-RAIM), is proposed for GPS integrity monitoring in the approach and landing phase. By introducing landmarks as pseudo-satellites, the VA-RAIM enriches the navigation observations to improve the performance of RAIM. In the method, a computer vision system photographs and matches these landmarks to obtain additional measurements for navigation. Nevertheless, the challenging issue is that such additional measurements may suffer from vision errors. To ensure the reliability of the vision measurements, a GPS-based calibration algorithm is presented to reduce the time-invariant part of the vision errors. Then, the calibrated vision measurements are integrated with the GPS observations for integrity monitoring. Simulation results show that the VA-RAIM outperforms the conventional RAIM with a higher level of availability and fault detection rate. PMID:26378533

  2. Vision-Aided RAIM: A New Method for GPS Integrity Monitoring in Approach and Landing Phase.

    PubMed

    Fu, Li; Zhang, Jun; Li, Rui; Cao, Xianbin; Wang, Jinling

    2015-09-10

    In the 1980s, Global Positioning System (GPS) receiver autonomous integrity monitoring (RAIM) was proposed to provide the integrity of a navigation system by checking the consistency of GPS measurements. However, during the approach and landing phase of a flight path, where there is often low GPS visibility conditions, the performance of the existing RAIM method may not meet the stringent aviation requirements for availability and integrity due to insufficient observations. To solve this problem, a new RAIM method, named vision-aided RAIM (VA-RAIM), is proposed for GPS integrity monitoring in the approach and landing phase. By introducing landmarks as pseudo-satellites, the VA-RAIM enriches the navigation observations to improve the performance of RAIM. In the method, a computer vision system photographs and matches these landmarks to obtain additional measurements for navigation. Nevertheless, the challenging issue is that such additional measurements may suffer from vision errors. To ensure the reliability of the vision measurements, a GPS-based calibration algorithm is presented to reduce the time-invariant part of the vision errors. Then, the calibrated vision measurements are integrated with the GPS observations for integrity monitoring. Simulation results show that the VA-RAIM outperforms the conventional RAIM with a higher level of availability and fault detection rate.

  3. The Vision of "Industrie 4.0" in the Making-a Case of Future Told, Tamed, and Traded.

    PubMed

    Pfeiffer, Sabine

    2017-01-01

    Since industrial trade fair Hannover Messe 2011, the term "Industrie 4.0" has ignited a vision of a new Industrial Revolution and has been inspiring a lively, ongoing debate among the German public about the future of work, and hence society, ever since. The discourse around this vision of the future eventually spread to other countries, with public awareness reaching a temporary peak in 2016 when the World Economic Forum's meeting in Davos was held with the motto "Mastering the Fourth Industrial Revolution." How is it possible for a vision originally established by three German engineers to unfold and bear fruit at a global level in such a short period of time? This article begins with a summary of the key ideas that are discussed under the label Industrie 4.0. The main purpose, based on an in-depth discourse analysis, is to debunk the myth about the origin of this powerful vision and to trace the narrative back to the global economic crisis in 2009 and thus to the real actors, central discourse patterns, and hidden intentions of this vision of a new Industrial Revolution. In conclusion, the discourse analysis reveals that this is not a case of visioneering but one of a future told, tamed, and traded.

  4. Color vision impairments among shipyard workers exposed to mixed organic solvents, especially xylene.

    PubMed

    Lee, Eun-Hee; Paek, Domyung; Kho, Young Lim; Choi, Kyungho; Chae, Hong Jae

    2013-01-01

    We evaluated color vision impairment in workers exposed to organic solvents, especially xylene. Three groups of subjects, comprising 63 workers occupationally exposed to organic solvents, 122 non-exposed workers in the same industry, and 185 subjects from the general population as controls, were evaluated for color vision. Exposure to solvents was indirectly evaluated by measuring the concentration of a urinary metabolite. Color vision was assessed using the Lanthony Desaturated 15-hue (Lanthony D-15) panel. Color confusion index (CCI) values in the exposed group were significantly higher than in the non-exposed workers or the general population, after adjustment for age and education, and significantly correlated with the concentration of methylhippuric acid. Color vision impairments were detected more frequently among the exposed group, and the most common types were type III and complex impairments. The rate of type III impairments was 9.52% in the exposed group, 1.64% in the non-exposed group, and 1.62% in the general population. Our results support the hypothesis that acquired color vision impairments could be induced by exposure to xylene. Testing for color vision impairment is a relatively simple, non-invasive and sensitive diagnostic method for relatively low-level exposures to xylene. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Architectural frameworks: defining the structures for implementing learning health systems.

    PubMed

    Lessard, Lysanne; Michalowski, Wojtek; Fung-Kee-Fung, Michael; Jones, Lori; Grudniewicz, Agnes

    2017-06-23

    The vision of transforming health systems into learning health systems (LHSs) that rapidly and continuously transform knowledge into improved health outcomes at lower cost is generating increased interest in government agencies, health organizations, and health research communities. While existing initiatives demonstrate that different approaches can succeed in making the LHS vision a reality, they are too varied in their goals, focus, and scale to be reproduced without undue effort. Indeed, the structures necessary to effectively design and implement LHSs on a larger scale are lacking. In this paper, we propose the use of architectural frameworks to develop LHSs that adhere to a recognized vision while being adapted to their specific organizational context. Architectural frameworks are high-level descriptions of an organization as a system; they capture the structure of its main components at varied levels, the interrelationships among these components, and the principles that guide their evolution. Because these frameworks support the analysis of LHSs and allow their outcomes to be simulated, they act as pre-implementation decision-support tools that identify potential barriers and enablers of system development. They thus increase the chances of successful LHS deployment. We present an architectural framework for LHSs that incorporates five dimensions-goals, scientific, social, technical, and ethical-commonly found in the LHS literature. The proposed architectural framework is comprised of six decision layers that model these dimensions. The performance layer models goals, the scientific layer models the scientific dimension, the organizational layer models the social dimension, the data layer and information technology layer model the technical dimension, and the ethics and security layer models the ethical dimension. We describe the types of decisions that must be made within each layer and identify methods to support decision-making. In this paper, we outline a high-level architectural framework grounded in conceptual and empirical LHS literature. Applying this architectural framework can guide the development and implementation of new LHSs and the evolution of existing ones, as it allows for clear and critical understanding of the types of decisions that underlie LHS operations. Further research is required to assess and refine its generalizability and methods.

  6. Visual performance of four simultaneous-image multifocal contact lenses under dim and glare conditions.

    PubMed

    García-Lázaro, Santiago; Ferrer-Blasco, Teresa; Madrid-Costa, David; Albarrán-Diego, César; Montés-Micó, Robert

    2015-01-01

    To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare. In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; Bausch & Lomb], Acuvue Oasys for Presbyopia [AOP; Johnson & Johnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wearing, each subject's binocular distance visual acuity (BDVA) and binocular distance contrast sensitivity (BDCS) were measured using the Functional Visual Analyzer (Stereo Optical Co., Inc.) under mesopic conditions (3 candela [cd]/m) both with no glare and under the 2 levels of induced glare: 1.0 lux (glare 1) and 28 lux (glare 2). Among the SIMCLs, in terms of BDVA, AOAM and PM outperformed BM and AOP. All contact lenses performed better at level without glare, followed by Glare 1, and with the worst results obtained under glare 2. Binocular distance contrast sensitivity revealed statistically significant differences for 12 cycles per degree (cpd). Among the SIMCLs, post hoc multiple comparison testing revealed that AOAM and PM provided the best BDCS at the three luminance levels. In both cases, BDVA and BDCS at 12 cpd, monofocal contact lenses outperformed all SIMCL ones at all lighting conditions. Air Optix Aqua Multifocal and PM provided better visual performance than BM and AOP for distance vision with low addition and under dim conditions, but they all provide worse performance than monofocal contact lenses.

  7. Spatial learning while navigating with severely degraded viewing: The role of attention and mobility monitoring

    PubMed Central

    Rand, Kristina M.; Creem-Regehr, Sarah H.; Thompson, William B.

    2015-01-01

    The ability to navigate without getting lost is an important aspect of quality of life. In five studies, we evaluated how spatial learning is affected by the increased demands of keeping oneself safe while walking with degraded vision (mobility monitoring). We proposed that safe low-vision mobility requires attentional resources, providing competition for those needed to learn a new environment. In Experiments 1 and 2 participants navigated along paths in a real-world indoor environment with simulated degraded vision or normal vision. Memory for object locations seen along the paths was better with normal compared to degraded vision. With degraded vision, memory was better when participants were guided by an experimenter (low monitoring demands) versus unguided (high monitoring demands). In Experiments 3 and 4, participants walked while performing an auditory task. Auditory task performance was superior with normal compared to degraded vision. With degraded vision, auditory task performance was better when guided compared to unguided. In Experiment 5, participants performed both the spatial learning and auditory tasks under degraded vision. Results showed that attention mediates the relationship between mobility-monitoring demands and spatial learning. These studies suggest that more attention is required and spatial learning is impaired when navigating with degraded viewing. PMID:25706766

  8. Use of 3D vision for fine robot motion

    NASA Technical Reports Server (NTRS)

    Lokshin, Anatole; Litwin, Todd

    1989-01-01

    An integration of 3-D vision systems with robot manipulators will allow robots to operate in a poorly structured environment by visually locating targets and obstacles. However, by using computer vision for objects acquisition makes the problem of overall system calibration even more difficult. Indeed, in a CAD based manipulation a control architecture has to find an accurate mapping between the 3-D Euclidean work space and a robot configuration space (joint angles). If a stereo vision is involved, then one needs to map a pair of 2-D video images directly into the robot configuration space. Neural Network approach aside, a common solution to this problem is to calibrate vision and manipulator independently, and then tie them via common mapping into the task space. In other words, both vision and robot refer to some common Absolute Euclidean Coordinate Frame via their individual mappings. This approach has two major difficulties. First a vision system has to be calibrated over the total work space. And second, the absolute frame, which is usually quite arbitrary, has to be the same with a high degree of precision for both robot and vision subsystem calibrations. The use of computer vision to allow robust fine motion manipulation in a poorly structured world which is currently in progress is described along with the preliminary results and encountered problems.

  9. Community screening for visual impairment in older people.

    PubMed

    Clarke, Emily L; Evans, Jennifer R; Smeeth, Liam

    2018-02-20

    Visual problems in older people are common and frequently under-reported. The effects of poor vision in older people are wide reaching and include falls, confusion and reduced quality of life. Much of the visual impairment in older ages can be treated (e.g. cataract surgery, correction of refractive error). Vision screening may therefore reduce the number of older people living with sight loss. The objective of this review was to assess the effects on vision of community vision screening of older people for visual impairment. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 10); Ovid MEDLINE; Ovid Embase; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 23 November 2017. We included randomised controlled trials (RCTs) that compared vision screening alone or as part of a multi-component screening package as compared to no vision screening or standard care, on the vision of people aged 65 years or over in a community setting. We included trials that used self-reported visual problems or visual acuity testing as the screening tool. We used standard methods expected by Cochrane. We graded the certainty of the evidence using GRADE. Visual outcome data were available for 10,608 people in 10 trials. Four trials took place in the UK, two in Australia, two in the United States and two in the Netherlands. Length of follow-up ranged from one to five years. Three of these studies were cluster-randomised trials whereby general practitioners or family physicians were randomly allocated to undertake vision screening or no vision screening. All studies were funded by government agencies. Overall we judged the studies to be at low risk of bias and only downgraded the certainty of the evidence (GRADE) for imprecision.Seven trials compared vision screening as part of a multi-component screening versus no screening. Six of these studies used self-reported vision as both screening tool and outcome measure, but did not directly measure vision. One study used a combination of self-reported vision and visual acuity measurement: participants reporting vision problems at screening were treated by the attending doctor, referred to an eye care specialist or given information about resources that were available to assist with poor vision. There was a similar risk of "not seeing well" at follow-up in people screened compared with people not screened in meta-analysis of six studies (risk ratio (RR) 1.05, 95% confidence interval (CI) 0.97 to 1.14, 4522 participants high-certainty evidence). One trial reported "improvement in vision" and this occurred slightly less frequently in the screened group (RR 0.85, 95% CI 0.52 to 1.40, 230 participants, moderate-certainty evidence).Two trials compared vision screening (visual acuity testing) alone with no vision screening. In one study, distance visual acuity was similar in the two groups at follow-up (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.05, 532 participants, high-certainty evidence). There was also little difference in near acuity (MD 0.02 logMAR, 95% CI -0.03 to 0.07, 532 participants, high-certainty evidence). There was no evidence of any important difference in quality of life (MD -0.06 National Eye Institute 25-item visual function questionnaire (VFQ-25) score adjusted for baseline VFQ-25 score, 95% CI -2.3 to 1.1, 532 participants, high-certainty evidence). The other study could not be included in the data analysis as the number of participants in each of the arms at follow-up could not be determined. However the authors stated that there was no significant difference in mean visual acuity in participants who had visual acuity assessed at baseline (39 letters) as compared to those who did not have their visual acuity assessed (35 letters, P = 0.25, 121 participants).One trial compared a detailed health assessment including measurement of visual acuity (intervention) with a brief health assessment including one question about vision (standard care). People given the detailed health assessment had a similar risk of visual impairment (visual acuity worse than 6/18 in either eye) at follow-up compared with people given the brief assessment (RR 1.07, 95% CI 0.84 to 1.36, 1807 participants, moderate-certainty evidence). The mean composite score of the VFQ-25 was 86.0 in the group that underwent visual acuity screening compared with 85.6 in the standard care group, a difference of 0.40 (95% CI -1.70 to 2.50, 1807 participants, high-certainty evidence). The evidence from RCTs undertaken to date does not support vision screening for older people living independently in a community setting, whether in isolation or as part of a multi-component screening package. This is true for screening programmes involving questions about visual problems, or direct measurements of visual acuity.The most likely reason for this negative review is that the populations within the trials often did not take up the offered intervention as a result of the vision screening and large proportions of those who did not have vision screening appeared to seek their own intervention. Also, trials that use questions about vision have a lower sensitivity and specificity than formal visual acuity testing. Given the importance of visual impairment among older people, further research into strategies to improve vision of older people is needed. The effectiveness of an optimised primary care-based screening intervention that overcomes possible factors contributing to the observed lack of benefit in trials to date warrants assessment; trials should consider including more dependent participants, rather than those living independently in the community.

  10. Model-based video segmentation for vision-augmented interactive games

    NASA Astrophysics Data System (ADS)

    Liu, Lurng-Kuo

    2000-04-01

    This paper presents an architecture and algorithms for model based video object segmentation and its applications to vision augmented interactive game. We are especially interested in real time low cost vision based applications that can be implemented in software in a PC. We use different models for background and a player object. The object segmentation algorithm is performed in two different levels: pixel level and object level. At pixel level, the segmentation algorithm is formulated as a maximizing a posteriori probability (MAP) problem. The statistical likelihood of each pixel is calculated and used in the MAP problem. Object level segmentation is used to improve segmentation quality by utilizing the information about the spatial and temporal extent of the object. The concept of an active region, which is defined based on motion histogram and trajectory prediction, is introduced to indicate the possibility of a video object region for both background and foreground modeling. It also reduces the overall computation complexity. In contrast with other applications, the proposed video object segmentation system is able to create background and foreground models on the fly even without introductory background frames. Furthermore, we apply different rate of self-tuning on the scene model so that the system can adapt to the environment when there is a scene change. We applied the proposed video object segmentation algorithms to several prototype virtual interactive games. In our prototype vision augmented interactive games, a player can immerse himself/herself inside a game and can virtually interact with other animated characters in a real time manner without being constrained by helmets, gloves, special sensing devices, or background environment. The potential applications of the proposed algorithms including human computer gesture interface and object based video coding such as MPEG-4 video coding.

  11. Baseline traits of low vision patients served by private outpatient clinical centers in the United States.

    PubMed

    Goldstein, Judith E; Massof, Robert W; Deremeik, James T; Braudway, Sonya; Jackson, Mary Lou; Kehler, K Bradley; Primo, Susan A; Sunness, Janet S

    2012-08-01

    To characterize the traits of low vision patients who seek outpatient low vision rehabilitation (LVR) services in the United States. In a prospective observational study, we enrolled 764 new low vision patients seeking outpatient LVR services from 28 clinical centers in the United States. Before their initial appointment, multiple questionnaires assessing daily living and vision, physical, psychological, and cognitive health states were administered by telephone. Baseline clinical visual impairment measures and disorder diagnoses were recorded. Patients had a median age of 77 years, were primarily female (66%), and had macular disease (55%), most of which was nonneovascular age-related macular degeneration. More than one-third of the patients (37%) had mild vision impairment with habitual visual acuity (VA) of 20/60 or greater. The VA correlated well with contrast sensitivity (r = -0.52) but poorly with self-reported vision quality. The intake survey revealed self-reported physical health limitations, including decreased endurance (68%) and mobility problems (52%). Many patients reported increased levels of frustration (42%) and depressed mood (22%); memory and cognitive impairment (11%) were less frequently endorsed. Patients relied on others for daily living support (87%), but many (31%) still drove. Most patients seeking LVR are geriatric and have macular disease with relatively preserved VA. The disparity between VA and subjective quality of vision suggests that LVR referrals are based on symptoms rather than on VA alone. Patients seen for LVR services have significant physical, psychological, and cognitive disorders that can amplify vision disabilities and decrease rehabilitation potential.

  12. Sensor fusion II: Human and machine strategies; Proceedings of the Meeting, Philadelphia, PA, Nov. 6-9, 1989

    NASA Technical Reports Server (NTRS)

    Schenker, Paul S. (Editor)

    1990-01-01

    Various papers on human and machine strategies in sensor fusion are presented. The general topics addressed include: active vision, measurement and analysis of visual motion, decision models for sensor fusion, implementation of sensor fusion algorithms, applying sensor fusion to image analysis, perceptual modules and their fusion, perceptual organization and object recognition, planning and the integration of high-level knowledge with perception, using prior knowledge and context in sensor fusion.

  13. Camera calibration method of binocular stereo vision based on OpenCV

    NASA Astrophysics Data System (ADS)

    Zhong, Wanzhen; Dong, Xiaona

    2015-10-01

    Camera calibration, an important part of the binocular stereo vision research, is the essential foundation of 3D reconstruction of the spatial object. In this paper, the camera calibration method based on OpenCV (open source computer vision library) is submitted to make the process better as a result of obtaining higher precision and efficiency. First, the camera model in OpenCV and an algorithm of camera calibration are presented, especially considering the influence of camera lens radial distortion and decentering distortion. Then, camera calibration procedure is designed to compute those parameters of camera and calculate calibration errors. High-accurate profile extraction algorithm and a checkboard with 48 corners have also been used in this part. Finally, results of calibration program are presented, demonstrating the high efficiency and accuracy of the proposed approach. The results can reach the requirement of robot binocular stereo vision.

  14. Ability of the D-15 panel tests and HRR pseudoisochromatic plates to predict performance in naming VDT colors.

    PubMed

    Ramaswamy, Shankaran; Hovis, Jeffery K

    2004-01-01

    Color codes in VDT displays often contain sets of colors that are confusing to individuals with color-vision deficiencies. The purpose of this study is to determine whether individuals with color-vision deficiencies (color defectives) can perform as well as individuals without color-vision deficiencies (color normals) on a colored VDT display used in the railway industry and to determine whether clinical color-vision tests can predict their performance. Of the 52 color defectives, 58% failed the VDT test. The kappa coefficients of agreement for the Farnsworth D-15, Adams desaturated D-15, and Richmond 3rd Edition HRR PIC diagnostic plates were significantly greater than chance. In particular, the D-15 tests have a high probability of predicting who fails the practical test. However, all three tests had an unacceptably high false-negative rate (9.5-35%); so that a practical test is still needed.

  15. Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

    PubMed

    Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang

    2014-01-01

    An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.

  16. Representing vision and blindness.

    PubMed

    Ray, Patrick L; Cox, Alexander P; Jensen, Mark; Allen, Travis; Duncan, William; Diehl, Alexander D

    2016-01-01

    There have been relatively few attempts to represent vision or blindness ontologically. This is unsurprising as the related phenomena of sight and blindness are difficult to represent ontologically for a variety of reasons. Blindness has escaped ontological capture at least in part because: blindness or the employment of the term 'blindness' seems to vary from context to context, blindness can present in a myriad of types and degrees, and there is no precedent for representing complex phenomena such as blindness. We explore current attempts to represent vision or blindness, and show how these attempts fail at representing subtypes of blindness (viz., color blindness, flash blindness, and inattentional blindness). We examine the results found through a review of current attempts and identify where they have failed. By analyzing our test cases of different types of blindness along with the strengths and weaknesses of previous attempts, we have identified the general features of blindness and vision. We propose an ontological solution to represent vision and blindness, which capitalizes on resources afforded to one who utilizes the Basic Formal Ontology as an upper-level ontology. The solution we propose here involves specifying the trigger conditions of a disposition as well as the processes that realize that disposition. Once these are specified we can characterize vision as a function that is realized by certain (in this case) biological processes under a range of triggering conditions. When the range of conditions under which the processes can be realized are reduced beyond a certain threshold, we are able to say that blindness is present. We characterize vision as a function that is realized as a seeing process and blindness as a reduction in the conditions under which the sight function is realized. This solution is desirable because it leverages current features of a major upper-level ontology, accurately captures the phenomenon of blindness, and can be implemented in many domain-specific ontologies.

  17. Training-induced recovery of low-level vision followed by mid-level perceptual improvements in developmental object and face agnosia

    PubMed Central

    Lev, Maria; Gilaie-Dotan, Sharon; Gotthilf-Nezri, Dana; Yehezkel, Oren; Brooks, Joseph L; Perry, Anat; Bentin, Shlomo; Bonneh, Yoram; Polat, Uri

    2015-01-01

    Long-term deprivation of normal visual inputs can cause perceptual impairments at various levels of visual function, from basic visual acuity deficits, through mid-level deficits such as contour integration and motion coherence, to high-level face and object agnosia. Yet it is unclear whether training during adulthood, at a post-developmental stage of the adult visual system, can overcome such developmental impairments. Here, we visually trained LG, a developmental object and face agnosic individual. Prior to training, at the age of 20, LG's basic and mid-level visual functions such as visual acuity, crowding effects, and contour integration were underdeveloped relative to normal adult vision, corresponding to or poorer than those of 5–6 year olds (Gilaie-Dotan, Perry, Bonneh, Malach & Bentin, 2009). Intensive visual training, based on lateral interactions, was applied for a period of 9 months. LG's directly trained but also untrained visual functions such as visual acuity, crowding, binocular stereopsis and also mid-level contour integration improved significantly and reached near-age-level performance, with long-term (over 4 years) persistence. Moreover, mid-level functions that were tested post-training were found to be normal in LG. Some possible subtle improvement was observed in LG's higher-order visual functions such as object recognition and part integration, while LG's face perception skills have not improved thus far. These results suggest that corrective training at a post-developmental stage, even in the adult visual system, can prove effective, and its enduring effects are the basis for a revival of a developmental cascade that can lead to reduced perceptual impairments. PMID:24698161

  18. Training-induced recovery of low-level vision followed by mid-level perceptual improvements in developmental object and face agnosia.

    PubMed

    Lev, Maria; Gilaie-Dotan, Sharon; Gotthilf-Nezri, Dana; Yehezkel, Oren; Brooks, Joseph L; Perry, Anat; Bentin, Shlomo; Bonneh, Yoram; Polat, Uri

    2015-01-01

    Long-term deprivation of normal visual inputs can cause perceptual impairments at various levels of visual function, from basic visual acuity deficits, through mid-level deficits such as contour integration and motion coherence, to high-level face and object agnosia. Yet it is unclear whether training during adulthood, at a post-developmental stage of the adult visual system, can overcome such developmental impairments. Here, we visually trained LG, a developmental object and face agnosic individual. Prior to training, at the age of 20, LG's basic and mid-level visual functions such as visual acuity, crowding effects, and contour integration were underdeveloped relative to normal adult vision, corresponding to or poorer than those of 5-6 year olds (Gilaie-Dotan, Perry, Bonneh, Malach & Bentin, 2009). Intensive visual training, based on lateral interactions, was applied for a period of 9 months. LG's directly trained but also untrained visual functions such as visual acuity, crowding, binocular stereopsis and also mid-level contour integration improved significantly and reached near-age-level performance, with long-term (over 4 years) persistence. Moreover, mid-level functions that were tested post-training were found to be normal in LG. Some possible subtle improvement was observed in LG's higher-order visual functions such as object recognition and part integration, while LG's face perception skills have not improved thus far. These results suggest that corrective training at a post-developmental stage, even in the adult visual system, can prove effective, and its enduring effects are the basis for a revival of a developmental cascade that can lead to reduced perceptual impairments. © 2014 The Authors. Developmental Science Published by John Wiley & Sons Ltd.

  19. A vision system planner for increasing the autonomy of the Extravehicular Activity Helper/Retriever

    NASA Technical Reports Server (NTRS)

    Magee, Michael

    1993-01-01

    The Extravehicular Activity Retriever (EVAR) is a robotic device currently being developed by the Automation and Robotics Division at the NASA Johnson Space Center to support activities in the neighborhood of the Space Shuttle or Space Station Freedom. As the name implies, the Retriever's primary function will be to provide the capability to retrieve tools and equipment or other objects which have become detached from the spacecraft, but it will also be able to rescue a crew member who may have become inadvertently de-tethered. Later goals will include cooperative operations between a crew member and the Retriever such as fetching a tool that is required for servicing or maintenance operations. This paper documents a preliminary design for a Vision System Planner (VSP) for the EVAR that is capable of achieving visual objectives provided to it by a high level task planner. Typical commands which the task planner might issue to the VSP relate to object recognition, object location determination, and obstacle detection. Upon receiving a command from the task planner, the VSP then plans a sequence of actions to achieve the specified objective using a model-based reasoning approach. This sequence may involve choosing an appropriate sensor, selecting an algorithm to process the data, reorienting the sensor, adjusting the effective resolution of the image using lens zooming capability, and/or requesting the task planner to reposition the EVAR to obtain a different view of the object. An initial version of the Vision System Planner which realizes the above capabilities using simulated images has been implemented and tested. The remaining sections describe the architecture and capabilities of the VSP and its relationship to the high level task planner. In addition, typical plans that are generated to achieve visual goals for various scenarios are discussed. Specific topics to be addressed will include object search strategies, repositioning of the EVAR to improve the quality of information obtained from the sensors, and complementary usage of the sensors and redundant capabilities.

  20. No Evidence of Narrowly Defined Cognitive Penetrability in Unambiguous Vision

    PubMed Central

    Lammers, Nikki A.; de Haan, Edward H.; Pinto, Yair

    2017-01-01

    The classical notion of cognitive impenetrability suggests that perceptual processing is an automatic modular system and not under conscious control. Near consensus is now emerging that this classical notion is untenable. However, as recently pointed out by Firestone and Scholl, this consensus is built on quicksand. In most studies claiming perception is cognitively penetrable, it remains unclear which actual process has been affected (perception, memory, imagery, input selection or judgment). In fact, the only available “proofs” for cognitive penetrability are proxies for perception, such as behavioral responses and neural correlates. We suggest that one can interpret cognitive penetrability in two different ways, a broad sense and a narrow sense. In the broad sense, attention and memory are not considered as “just” pre- and post-perceptual systems but as part of the mechanisms by which top-down processes influence the actual percept. Although many studies have proven top-down influences in this broader sense, it is still debatable whether cognitive penetrability remains tenable in a narrow sense. The narrow sense states that cognitive penetrability only occurs when top-down factors are flexible and cause a clear illusion from a first person perspective. So far, there is no strong evidence from a first person perspective that visual illusions can indeed be driven by high-level flexible factors. One cannot be cognitively trained to see and unsee visual illusions. We argue that this lack of convincing proof for cognitive penetrability in the narrow sense can be explained by the fact that most research focuses on foveal vision only. This type of perception may be too unambiguous for transient high-level factors to control perception. Therefore, illusions in more ambiguous perception, such as peripheral vision, can offer a unique insight into the matter. They produce a clear subjective percept based on unclear, degraded visual input: the optimal basis to study narrowly defined cognitive penetrability. PMID:28740471

  1. Attention and multisensory modulation argue against total encapsulation.

    PubMed

    de Haas, Benjamin; Schwarzkopf, Dietrich Samuel; Rees, Geraint

    2016-01-01

    Firestone & Scholl (F&S) postulate that vision proceeds without any direct interference from cognition. We argue that this view is extreme and not in line with the available evidence. Specifically, we discuss two well-established counterexamples: Attention directly affects core aspects of visual processing, and multisensory modulations of vision originate on multiple levels, some of which are unlikely to fall "within perception."

  2. Principles of Good Principals: Effective Leadership Brings a Board's Vision to the School Level

    ERIC Educational Resources Information Center

    Martineau, Pamela

    2012-01-01

    The importance of effective principals to school reform is well-documented. But what makes a school principal an effective change agent, and how can a school board and district administrators assist in pushing their top site leaders to excellence? Many district and board leaders say it's all about vision, building trust with staff, and developing…

  3. How does visual manipulation affect obstacle avoidance strategies used by athletes?

    PubMed

    Bijman, M P; Fisher, J J; Vallis, L A

    2016-01-01

    Research examining our ability to avoid obstacles in our path has stressed the importance of visual input. The aim of this study was to determine if athletes playing varsity-level field sports, who rely on visual input to guide motor behaviour, are more able to guide their foot over obstacles compared to recreational individuals. While wearing kinematic markers, eight varsity athletes and eight age-matched controls (aged 18-25) walked along a walkway and stepped over stationary obstacles (180° motion arc). Visual input was manipulated using PLATO visual goggles three or two steps pre-obstacle crossing and compared to trials where vision was given throughout. A main effect between groups for peak trail toe elevation was shown with greater values generated by the controls for all crossing conditions during full vision trials only. This may be interpreted as athletes not perceiving this obstacle as an increased threat to their postural stability. Collectively, findings suggest the athletic group is able to transfer their abilities to non-specific conditions during full vision trials; however, varsity-level athletes were equally reliant on visual cues for these visually guided stepping tasks as their performance was similar to the controls when vision is removed.

  4. NSTA Pathways to the Science Standards: Guidelines for Moving the Vision into Practice. High School School Edition.

    ERIC Educational Resources Information Center

    Texley, Juliana, Ed.; Wild, Ann, Ed.

    This book is designed for high school teachers and contains tools to guide teaching, professional development, assessment, program and curriculum, and interactions with the education system working towards the vision of the National Science Education Standards. The first three and last two chapters discuss the Standards that apply to all K-12…

  5. Instructional Partnerships to Extend Learning in Urban High Schools: Lessons from New York City and Boston

    ERIC Educational Resources Information Center

    Foley, Eileen M.; Allender, Sara; Cooc, North; Edwards, Sara; Riley, Derek R.; Reisner, Elizabeth R.

    2009-01-01

    Late in 2007 New Visions for Public Schools, a New York City reform organization, received a grant from the C.S. Mott Foundation to organize select high schools and community partners into delivery systems that could improve student achievement. New Visions asked Policy Studies Associates, Inc. to provide research support for this effort in the…

  6. Cone arrestin confers cone vision of high temporal resolution in zebrafish larvae.

    PubMed

    Renninger, Sabine L; Gesemann, Matthias; Neuhauss, Stephan C F

    2011-02-01

    Vision of high temporal resolution depends on careful regulation of photoresponse kinetics, beginning with the lifetime of activated photopigment. The activity of rhodopsin is quenched by high-affinity binding of arrestin to photoexcited phosphorylated photopigment, which effectively terminates the visual transduction cascade. This regulation mechanism is well established for rod photoreceptors, yet its role for cone vision is still controversial. In this study we therefore analyzed arrestin function in the cone-dominated vision of larval zebrafish. For both rod (arrS ) and cone (arr3 ) arrestin we isolated two paralogs, each expressed in the respective subset of photoreceptors. Labeling with paralog-specific antibodies revealed subfunctionalized expression of Arr3a in M- and L-cones, and Arr3b in S- and UV-cones. The inactivation of arr3a by morpholino knockdown technology resulted in a severe delay in photoresponse recovery which, under bright light conditions, was rate-limiting. Comparison to opsin phosphorylation-deficient animals confirmed the role of cone arrestin in late cone response recovery. Arr3a activity partially overlapped with the function of the cone-specific kinase Grk7a involved in initial response recovery. Behavioral measurements further revealed Arr3a deficiency to be sufficient to reduce temporal contrast sensitivity, providing evidence for the importance of arrestin in cone vision of high temporal resolution. © 2011 The Authors. European Journal of Neuroscience © 2011 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  7. "They Think They Know What's Best for Me": An Interpretative Phenomenological Analysis of the Experience of Inclusion and Support in High School for Vision-Impaired Students with Albinism

    ERIC Educational Resources Information Center

    Thurston, Mhairi

    2014-01-01

    The challenges of social inclusion and access to the curriculum facing students with visual impairment in schools are well documented. The refreshed UK Vision Strategy (2013) seeks to improve education for students with vision impairment. In order to do this, it is important to understand how students with visual impairment experience education.…

  8. Positive selection rather than relaxation of functional constraint drives the evolution of vision during chicken domestication.

    PubMed

    Wang, Ming-Shan; Zhang, Rong-Wei; Su, Ling-Yan; Li, Yan; Peng, Min-Sheng; Liu, He-Qun; Zeng, Lin; Irwin, David M; Du, Jiu-Lin; Yao, Yong-Gang; Wu, Dong-Dong; Zhang, Ya-Ping

    2016-05-01

    As noted by Darwin, chickens have the greatest phenotypic diversity of all birds, but an interesting evolutionary difference between domestic chickens and their wild ancestor, the Red Junglefowl, is their comparatively weaker vision. Existing theories suggest that diminished visual prowess among domestic chickens reflect changes driven by the relaxation of functional constraints on vision, but the evidence identifying the underlying genetic mechanisms responsible for this change has not been definitively characterized. Here, a genome-wide analysis of the domestic chicken and Red Junglefowl genomes showed significant enrichment for positively selected genes involved in the development of vision. There were significant differences between domestic chickens and their wild ancestors regarding the level of mRNA expression for these genes in the retina. Numerous additional genes involved in the development of vision also showed significant differences in mRNA expression between domestic chickens and their wild ancestors, particularly for genes associated with phototransduction and photoreceptor development, such as RHO (rhodopsin), GUCA1A, PDE6B and NR2E3. Finally, we characterized the potential role of the VIT gene in vision, which experienced positive selection and downregulated expression in the retina of the village chicken. Overall, our results suggest that positive selection, rather than relaxation of purifying selection, contributed to the evolution of vision in domestic chickens. The progenitors of domestic chickens harboring weaker vision may have showed a reduced fear response and vigilance, making them easier to be unconsciously selected and/or domesticated.

  9. Functional vision and cognition in infants with congenital disorders of the peripheral visual system.

    PubMed

    Dale, Naomi; Sakkalou, Elena; O'Reilly, Michelle; Springall, Clare; De Haan, Michelle; Salt, Alison

    2017-07-01

    To investigate how vision relates to early development by studying vision and cognition in a national cohort of 1-year-old infants with congenital disorders of the peripheral visual system and visual impairment. This was a cross-sectional observational investigation of a nationally recruited cohort of infants with 'simple' and 'complex' congenital disorders of the peripheral visual system. Entry age was 8 to 16 months. Vision level (Near Detection Scale) and non-verbal cognition (sensorimotor understanding, Reynell Zinkin Scales) were assessed. Parents completed demographic questionnaires. Of 90 infants (49 males, 41 females; mean 13mo, standard deviation [SD] 2.5mo; range 7-17mo); 25 (28%) had profound visual impairment (light perception at best) and 65 (72%) had severe visual impairment (basic 'form' vision). The Near Detection Scale correlated significantly with sensorimotor understanding developmental quotients in the 'total', 'simple', and 'complex' groups (all p<0.001). Age and vision accounted for 48% of sensorimotor understanding variance. Infants with profound visual impairment, especially in the 'complex' group with congenital disorders of the peripheral visual system with known brain involvement, showed the greatest cognitive delay. Lack of vision is associated with delayed early-object manipulative abilities and concepts; 'form' vision appeared to support early developmental advance. This paper provides baseline characteristics for cross-sectional and longitudinal follow-up investigations in progress. A methodological strength of the study was the representativeness of the cohort according to national epidemiological and population census data. © 2017 Mac Keith Press.

  10. Positive selection rather than relaxation of functional constraint drives the evolution of vision during chicken domestication

    PubMed Central

    Wang, Ming-Shan; Zhang, Rong-wei; Su, Ling-Yan; Li, Yan; Peng, Min-Sheng; Liu, He-Qun; Zeng, Lin; Irwin, David M; Du, Jiu-Lin; Yao, Yong-Gang; Wu, Dong-Dong; Zhang, Ya-Ping

    2016-01-01

    As noted by Darwin, chickens have the greatest phenotypic diversity of all birds, but an interesting evolutionary difference between domestic chickens and their wild ancestor, the Red Junglefowl, is their comparatively weaker vision. Existing theories suggest that diminished visual prowess among domestic chickens reflect changes driven by the relaxation of functional constraints on vision, but the evidence identifying the underlying genetic mechanisms responsible for this change has not been definitively characterized. Here, a genome-wide analysis of the domestic chicken and Red Junglefowl genomes showed significant enrichment for positively selected genes involved in the development of vision. There were significant differences between domestic chickens and their wild ancestors regarding the level of mRNA expression for these genes in the retina. Numerous additional genes involved in the development of vision also showed significant differences in mRNA expression between domestic chickens and their wild ancestors, particularly for genes associated with phototransduction and photoreceptor development, such as RHO (rhodopsin), GUCA1A, PDE6B and NR2E3. Finally, we characterized the potential role of the VIT gene in vision, which experienced positive selection and downregulated expression in the retina of the village chicken. Overall, our results suggest that positive selection, rather than relaxation of purifying selection, contributed to the evolution of vision in domestic chickens. The progenitors of domestic chickens harboring weaker vision may have showed a reduced fear response and vigilance, making them easier to be unconsciously selected and/or domesticated. PMID:27033669

  11. The Recovery of Optical Quality after Laser Vision Correction

    PubMed Central

    Jung, Hyeong-Gi

    2013-01-01

    Purpose To evaluate the optical quality after laser in situ keratomileusis (LASIK) or serial photorefractive keratectomy (PRK) using a double-pass system and to follow the recovery of optical quality after laser vision correction. Methods This study measured the visual acuity, manifest refraction and optical quality before and one day, one week, one month, and three months after laser vision correction. Optical quality parameters including the modulation transfer function, Strehl ratio and intraocular scattering were evaluated with a double-pass system. Results This study included 51 eyes that underwent LASIK and 57 that underwent PRK. The optical quality three months post-surgery did not differ significantly between these laser vision correction techniques. Furthermore, the preoperative and postoperative optical quality did not differ significantly in either group. Optical quality recovered within one week after LASIK but took between one and three months to recover after PRK. The optical quality of patients in the PRK group seemed to recover slightly more slowly than their uncorrected distance visual acuity. Conclusions Optical quality recovers to the preoperative level after laser vision correction, so laser vision correction is efficacious for correcting myopia. The double-pass system is a useful tool for clinical assessment of optical quality. PMID:23908570

  12. Validity of Teacher-Based Vision Screening and Factors Associated with the Accuracy of Vision Screening in Vietnamese Children.

    PubMed

    Paudel, Prakash; Kovai, Vilas; Naduvilath, Thomas; Phuong, Ha Thanh; Ho, Suit May; Giap, Nguyen Viet

    2016-01-01

    To assess validity of teacher-based vision screening and elicit factors associated with accuracy of vision screening in Vietnam. After brief training, teachers independently measured visual acuity (VA) in 555 children aged 12-15 years in Ba Ria - Vung Tau Province. Teacher VA measurements were compared to those of refractionists. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for uncorrected VA (UVA) and presenting VA (PVA) 20/40 or worse in either eye. Chi-square, Fisher's exact test and multivariate logistic regression were used to assess factors associated with accuracy of vision screening. Level of significance was set at 5%. Trained teachers in Vietnam demonstrated 86.7% sensitivity, 95.7% specificity, 86.7% positive predictive value and 95.7% negative predictive value in identifying children with visual impairment using the UVA measurement. PVA measurement revealed low accuracy for teachers, which was significantly associated with child's age, sex, spectacle wear and myopic status, but UVA measurement showed no such associations. Better accuracy was achieved in measurement of VA and identification of children with visual impairment using UVA measurement compared to PVA. UVA measurement is recommended for teacher-based vision screening programs.

  13. Ophthalmic changes and increased intracranial pressure associated with long duration spaceflight: An emerging understanding

    NASA Astrophysics Data System (ADS)

    Marshall-Bowman, Karina; Barratt, Michael R.; Gibson, C. Robert

    2013-06-01

    For many years, there have been anecdotal reports of vision changes by astronauts following short and long-duration spaceflight. Much of this was attributed to hyperopic shifts related to the age of the flying population. However, it has recently been recognized that vision changes are actually quite common in astronauts and are associated with a constellation of findings including elevated intracranial pressure, optic disc edema, globe flattening, optic nerve sheath thickening, hyperopic shifts and retinal changes. With advanced imaging modalities available on the ground along with the fidelity of in-flight diagnostic capabilities previously unavailable, information on this newly recognized syndrome is accumulating. As of this writing, 11 cases of visual impairment experienced by astronauts during missions on-board the International Space Station (ISS) have been documented and studied. Although the exact mechanisms of the vision changes are unknown, it is hypothesized that increased intracranial pressure (ICP) is a contributing factor. Microgravity is the dominant cause of many physiological changes during spaceflight and is thought to contribute significantly to the observed ophthalmic changes. However, several secondary factors that could contribute to increased ICP and vision changes in spaceflight have been proposed. Possible contributors include microgravity-induced cephalad fluid shift, venous obstruction due to microgravity-induced anatomical shifts, high levels of spacecraft cabin carbon dioxide, heavy resistive exercise, and high sodium diet. Individual susceptibility to visual impairment is not fully understood, though a demographic of affected astronauts is emerging. This paper describes the current understanding of this newly recognized syndrome, presents data from 11 individual cases, and discusses details of potential contributing factors. The occurrence of visual changes in long duration missions in microgravity is one of the most significant clinical issues to date for the human spaceflight community, and a comprehensive understanding of the issue at whole is critical to ensure safe space exploration in the future.

  14. Outcomes of Direct Vision Internal Urethrotomy for Bulbar Urethral Strictures: Technique Modification with High Dose Triamcinolone Injection.

    PubMed

    Modh, Rishi; Cai, Peter Y; Sheffield, Alyssa; Yeung, Lawrence L

    2015-01-01

    Objective. To evaluate the recurrence rate of bulbar urethral strictures managed with cold knife direct vision internal urethrotomy and high dose corticosteroid injection. Methods. 28 patients with bulbar urethral strictures underwent direct vision internal urethrotomy with high dose triamcinolone injection into the periurethral tissue and were followed up for recurrence. Results. Our cohort had a mean age of 60 years and average stricture length of 1.85 cm, and 71% underwent multiple previous urethral stricture procedures with an average of 5.7 procedures each. Our technique modification of high dose corticosteroid injection had a recurrence rate of 29% at a mean follow-up of 20 months with a low rate of urinary tract infections. In patients who failed treatment, mean time to stricture recurrence was 7 months. Patients who were successfully treated had significantly better International Prostate Symptom Scores at 6, 9, and 12 months. There was no significant difference in maximum flow velocity on Uroflowmetry at last follow-up but there was significant difference in length of follow-up (p = 0.02). Conclusions. High dose corticosteroid injection at the time of direct vision internal urethrotomy is a safe and effective procedure to delay anatomical and symptomatic recurrence of bulbar urethral strictures, particularly in those who are poor candidates for urethroplasty.

  15. Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2016-03-01

    Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model. The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09 mm (translations) and of [Formula: see text] (rotations), maximum observed errors in the order of 0.12 mm (translations) and of [Formula: see text] (rotations), and a reduction repeatability of 0.02 mm and [Formula: see text]. The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality.

  16. Measuring and tracking eye movements of a behaving archer fish by real-time stereo vision.

    PubMed

    Ben-Simon, Avi; Ben-Shahar, Ohad; Segev, Ronen

    2009-11-15

    The archer fish (Toxotes chatareus) exhibits unique visual behavior in that it is able to aim at and shoot down with a squirt of water insects resting on the foliage above water level and then feed on them. This extreme behavior requires excellent visual acuity, learning, and tight synchronization between the visual system and body motion. This behavior also raises many important questions, such as the fish's ability to compensate for air-water refraction and the neural mechanisms underlying target acquisition. While many such questions remain open, significant insights towards solving them can be obtained by tracking the eye and body movements of freely behaving fish. Unfortunately, existing tracking methods suffer from either a high level of invasiveness or low resolution. Here, we present a video-based eye tracking method for accurately and remotely measuring the eye and body movements of a freely moving behaving fish. Based on a stereo vision system and a unique triangulation method that corrects for air-glass-water refraction, we are able to measure a full three-dimensional pose of the fish eye and body with high temporal and spatial resolution. Our method, being generic, can be applied to studying the behavior of marine animals in general. We demonstrate how data collected by our method may be used to show that the hunting behavior of the archer fish is composed of surfacing concomitant with rotating the body around the direction of the fish's fixed gaze towards the target, until the snout reaches in the correct shooting position at water level.

  17. Optical functional performance of the osteo-odonto-keratoprosthesis.

    PubMed

    Lee, Richard M H; Ong, Gek L; Lam, Fook Chang; White, Joy; Crook, David; Liu, Christopher S C; Hull, Chris C

    2014-10-01

    The aim of this study was to evaluate optical and visual functional performance of the osteo-odonto-keratoprosthesis (OOKP). Optical design and analysis was performed with customized optical design software. Nine patients with implanted OOKP devices and 9 age-matched control patients were assessed. Contrast sensitivity was assessed and glare effect was measured with a brightness acuity test. All OOKP patients underwent kinetic Goldmann perimetry and wavefront aberrometry and completed the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). Optical analysis showed that the optical cylinder is near diffraction-limited. A reduction in median visual acuity (VA) with increasing glare settings was observed from 0.04 logMAR (without glare) to 0.20 logMAR (with glare at "high" setting) and significantly reduced statistically when compared with the control group at all levels of glare (P < 0.05). Contrast sensitivity was significantly reduced when compared with age-matched controls at medium and high spatial frequencies (P < 0.05). Median Goldmann perimetry was 65 degrees (interquartile range, 64-74 degrees; V-4e isopters) and 69 degrees excluding 2 glaucomatous subjects. Several vision-related NEI VFQ-25 subscales correlated significantly with VA at various brightness acuity test levels and contrast sensitivity at medium spatial frequencies, including dependency, general vision, near activities and distance activities. The OOKP optical cylinder provides patients with a good level of VA that is significantly reduced by glare. We have shown in vivo that updates to the optical cylinder design have improved the patient's field of view. Reduction of glare and refinement of cylinder alignment methods may further improve visual function and patient satisfaction.

  18. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies.

    PubMed

    Hussaindeen, Jameel Rizwana; Shah, Prerana; Ramani, Krishna Kumar; Ramanujan, Lalitha

    To report the frequency of binocular vision (BV) anomalies in children with specific learning disorders (SLD) and to assess the efficacy of vision therapy (VT) in children with a non-strabismic binocular vision anomaly (NSBVA). The study was carried out at a centre for learning disability (LD). Comprehensive eye examination and binocular vision assessment was carried out for 94 children (mean (SD) age: 15 (2.2) years) diagnosed with specific learning disorder. BV assessment was done for children with best corrected visual acuity of ≥6/9 - N6, cooperative for examination and free from any ocular pathology. For children with a diagnosis of NSBVA (n=46), 24 children were randomized to VT and no intervention was provided to the other 22 children who served as experimental controls. At the end of 10 sessions of vision therapy, BV assessment was performed for both the intervention and non-intervention groups. Binocular vision anomalies were found in 59 children (62.8%) among which 22% (n=13) had strabismic binocular vision anomalies (SBVA) and 78% (n=46) had a NSBVA. Accommodative infacility (AIF) was the commonest of the NSBVA and found in 67%, followed by convergence insufficiency (CI) in 25%. Post-vision therapy, the intervention group showed significant improvement in all the BV parameters (Wilcoxon signed rank test, p<0.05) except negative fusional vergence. Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  19. Feasibility of a clinical trial of vision therapy for treatment of amblyopia.

    PubMed

    Lyon, Don W; Hopkins, Kristine; Chu, Raymond H; Tamkins, Susanna M; Cotter, Susan A; Melia, B Michele; Holmes, Jonathan M; Repka, Michael X; Wheeler, David T; Sala, Nicholas A; Dumas, Janette; Silbert, David I

    2013-05-01

    We conducted a pilot randomized clinical trial of office-based active vision therapy for the treatment of childhood amblyopia to determine the feasibility of conducting a full-scale randomized clinical trial. A training and certification program and manual of procedures were developed to certify therapists to administer a standardized vision therapy program in ophthalmology and optometry offices consisting of weekly visits for 16 weeks. Nineteen children, aged 7 to less than 13 years, with amblyopia (20/40-20/100) were randomly assigned to receive either 2 hours of daily patching with active vision therapy or 2 hours of daily patching with placebo vision therapy. Therapists in diverse practice settings were successfully trained and certified to perform standardized vision therapy in strict adherence with protocol. Subjects completed 85% of required weekly in-office vision therapy visits. Eligibility criteria based on age, visual acuity, and stereoacuity, designed to identify children able to complete a standardized vision therapy program and judged likely to benefit from this treatment, led to a high proportion of screened subjects being judged ineligible, resulting in insufficient recruitment. There were difficulties in retrieving adherence data for the computerized home therapy procedures. This study demonstrated that a 16-week treatment trial of vision therapy was feasible with respect to maintaining protocol adherence; however, recruitment under the proposed eligibility criteria, necessitated by the standardized approach to vision therapy, was not successful. A randomized clinical trial of in-office vision therapy for the treatment of amblyopia would require broadening of the eligibility criteria and improved methods to gather objective data regarding the home therapy. A more flexible approach that customizes vision therapy based on subject age, visual acuity, and stereopsis might be required to allow enrollment of a broader group of subjects.

  20. Feasibility of a Clinical Trial of Vision Therapy for Treatment of Amblyopia

    PubMed Central

    Lyon, Don W.; Hopkins, Kristine; Chu, Raymond H.; Tamkins, Susanna M.; Cotter, Susan A.; Melia, B. Michele; Holmes, Jonathan M.; Repka, Michael X.; Wheeler, David T.; Sala, Nicholas A.; Dumas, Janette; Silbert, David I.

    2013-01-01

    Purpose We conducted a pilot randomized clinical trial of office-based active vision therapy for the treatment of childhood amblyopia to determine the feasibility of conducting a full-scale randomized clinical trial. Methods A training and certification program and manual of procedures were developed to certify therapists to administer a standardized vision therapy program in ophthalmology and optometry offices consisting of weekly visits for 16 weeks. Nineteen children, 7 to less than 13 years of age, with amblyopia (20/40–20/100) were randomly assigned to receive either 2 hours of daily patching with active vision therapy or 2 hours of daily patching with placebo vision therapy. Results Therapists in diverse practice settings were successfully trained and certified to perform standardized vision therapy in strict adherence with protocol. Subjects completed 85% of required weekly in-office vision therapy visits. Eligibility criteria based on age, visual acuity, and stereoacuity, designed to identify children able to complete a standardized vision therapy program and judged likely to benefit from this treatment, led to a high proportion of screened subjects being judged ineligible, resulting in insufficient recruitment. There were difficulties in retrieving adherence data for the computerized home therapy procedures. Conclusions This study demonstrated that a 16-week treatment trial of vision therapy was feasible with respect to maintaining protocol adherence; however, recruitment under the proposed eligibility criteria, necessitated by the standardized approach to vision therapy, was not successful. A randomized clinical trial of in-office vision therapy for the treatment of amblyopia would require broadening of the eligibility criteria and improved methods to gather objective data regarding the home therapy. A more flexible approach that customizes vision therapy based on subject age, visual acuity, and stereopsis, might be required to allow enrollment of a broader group of subjects. PMID:23563444

  1. ROBOSIGHT: Robotic Vision System For Inspection And Manipulation

    NASA Astrophysics Data System (ADS)

    Trivedi, Mohan M.; Chen, ChuXin; Marapane, Suresh

    1989-02-01

    Vision is an important sensory modality that can be used for deriving information critical to the proper, efficient, flexible, and safe operation of an intelligent robot. Vision systems are uti-lized for developing higher level interpretation of the nature of a robotic workspace using images acquired by cameras mounted on a robot. Such information can be useful for tasks such as object recognition, object location, object inspection, obstacle avoidance and navigation. In this paper we describe efforts directed towards developing a vision system useful for performing various robotic inspection and manipulation tasks. The system utilizes gray scale images and can be viewed as a model-based system. It includes general purpose image analysis modules as well as special purpose, task dependent object status recognition modules. Experiments are described to verify the robust performance of the integrated system using a robotic testbed.

  2. Near real-time stereo vision system

    NASA Technical Reports Server (NTRS)

    Anderson, Charles H. (Inventor); Matthies, Larry H. (Inventor)

    1993-01-01

    The apparatus for a near real-time stereo vision system for use with a robotic vehicle is described. The system is comprised of two cameras mounted on three-axis rotation platforms, image-processing boards, a CPU, and specialized stereo vision algorithms. Bandpass-filtered image pyramids are computed, stereo matching is performed by least-squares correlation, and confidence ranges are estimated by means of Bayes' theorem. In particular, Laplacian image pyramids are built and disparity maps are produced from the 60 x 64 level of the pyramids at rates of up to 2 seconds per image pair. The first autonomous cross-country robotic traverses (of up to 100 meters) have been achieved using the stereo vision system of the present invention with all computing done onboard the vehicle. The overall approach disclosed herein provides a unifying paradigm for practical domain-independent stereo ranging.

  3. Overview of sports vision

    NASA Astrophysics Data System (ADS)

    Moore, Linda A.; Ferreira, Jannie T.

    2003-03-01

    Sports vision encompasses the visual assessment and provision of sports-specific visual performance enhancement and ocular protection for athletes of all ages, genders and levels of participation. In recent years, sports vision has been identified as one of the key performance indicators in sport. It is built on four main cornerstones: corrective eyewear, protective eyewear, visual skills enhancement and performance enhancement. Although clinically well established in the US, it is still a relatively new area of optometric specialisation elsewhere in the world and is gaining increasing popularity with eyecare practitioners and researchers. This research is often multi-disciplinary and involves input from a variety of subject disciplines, mainly those of optometry, medicine, physiology, psychology, physics, chemistry, computer science and engineering. Collaborative research projects are currently underway between staff of the Schools of Physics and Computing (DIT) and the Academy of Sports Vision (RAU).

  4. High-Speed Camera and High-Vision Camera Observations of TLEs from Jet Aircraft in Winter Japan and in Summer US

    NASA Astrophysics Data System (ADS)

    Sato, M.; Takahashi, Y.; Kudo, T.; Yanagi, Y.; Kobayashi, N.; Yamada, T.; Project, N.; Stenbaek-Nielsen, H. C.; McHarg, M. G.; Haaland, R. K.; Kammae, T.; Cummer, S. A.; Yair, Y.; Lyons, W. A.; Ahrns, J.; Yukman, P.; Warner, T. A.; Sonnenfeld, R. G.; Li, J.; Lu, G.

    2011-12-01

    The time evolution and spatial distributions of transient luminous events (TLEs) are the key parameters to identify the relationship between TLEs and parent lightning discharges, roles of electromagnetic pulses (EMPs) emitted by horizontal and vertical lightning currents in the formation of TLEs, and the occurrence condition and mechanisms of TLEs. Since the time scales of TLEs is typically less than a few milliseconds, new imaging technique that enable us to capture images with a high time resolution of < 1ms is awaited. By courtesy of "Cosmic Shore" Project conducted by Japan Broadcasting Corporation (NHK), we have carried out optical observations using a high-speed Image-Intensified (II) CMOS camera and a high-vision three-CCD camera from a jet aircraft on November 28 and December 3, 2010 in winter Japan. Using the high-speed II-CMOS camera, it is possible to capture images with 8,300 frames per second (fps), which corresponds to the time resolution of 120 us. Using the high-vision three-CCD camera, it is possible to capture high quality, true color images of TLEs with a 1920x1080 pixel size and with a frame rate of 30 fps. During the two observation flights, we have succeeded to detect 28 sprite events, and 3 elves events totally. In response to this success, we have conducted a combined aircraft and ground-based campaign of TLE observations at the High Plains in summer US. We have installed same NHK high-speed and high-vision cameras in a jet aircraft. In the period from June 27 and July 10, 2011, we have operated aircraft observations in 8 nights, and we have succeeded to capture TLE images for over a hundred events by the high-vision camera and succeeded to acquire over 40 high-speed images simultaneously. At the presentation, we will introduce the outlines of the two aircraft campaigns, and will introduce the characteristics of the time evolution and spatial distributions of TLEs observed in winter Japan, and will show the initial results of high-speed image data analysis of TLEs in summer US.

  5. Automated design of image operators that detect interest points.

    PubMed

    Trujillo, Leonardo; Olague, Gustavo

    2008-01-01

    This work describes how evolutionary computation can be used to synthesize low-level image operators that detect interesting points on digital images. Interest point detection is an essential part of many modern computer vision systems that solve tasks such as object recognition, stereo correspondence, and image indexing, to name but a few. The design of the specialized operators is posed as an optimization/search problem that is solved with genetic programming (GP), a strategy still mostly unexplored by the computer vision community. The proposed approach automatically synthesizes operators that are competitive with state-of-the-art designs, taking into account an operator's geometric stability and the global separability of detected points during fitness evaluation. The GP search space is defined using simple primitive operations that are commonly found in point detectors proposed by the vision community. The experiments described in this paper extend previous results (Trujillo and Olague, 2006a,b) by presenting 15 new operators that were synthesized through the GP-based search. Some of the synthesized operators can be regarded as improved manmade designs because they employ well-known image processing techniques and achieve highly competitive performance. On the other hand, since the GP search also generates what can be considered as unconventional operators for point detection, these results provide a new perspective to feature extraction research.

  6. The remarkable visual capacities of nocturnal insects: vision at the limits with small eyes and tiny brains

    PubMed Central

    2017-01-01

    Nocturnal insects have evolved remarkable visual capacities, despite small eyes and tiny brains. They can see colour, control flight and land, react to faint movements in their environment, navigate using dim celestial cues and find their way home after a long and tortuous foraging trip using learned visual landmarks. These impressive visual abilities occur at light levels when only a trickle of photons are being absorbed by each photoreceptor, begging the question of how the visual system nonetheless generates the reliable signals needed to steer behaviour. In this review, I attempt to provide an answer to this question. Part of the answer lies in their compound eyes, which maximize light capture. Part lies in the slow responses and high gains of their photoreceptors, which improve the reliability of visual signals. And a very large part lies in the spatial and temporal summation of these signals in the optic lobe, a strategy that substantially enhances contrast sensitivity in dim light and allows nocturnal insects to see a brighter world, albeit a slower and coarser one. What is abundantly clear, however, is that during their evolution insects have overcome several serious potential visual limitations, endowing them with truly extraordinary night vision. This article is part of the themed issue ‘Vision in dim light’. PMID:28193808

  7. Real-time machine vision system using FPGA and soft-core processor

    NASA Astrophysics Data System (ADS)

    Malik, Abdul Waheed; Thörnberg, Benny; Meng, Xiaozhou; Imran, Muhammad

    2012-06-01

    This paper presents a machine vision system for real-time computation of distance and angle of a camera from reference points in the environment. Image pre-processing, component labeling and feature extraction modules were modeled at Register Transfer (RT) level and synthesized for implementation on field programmable gate arrays (FPGA). The extracted image component features were sent from the hardware modules to a soft-core processor, MicroBlaze, for computation of distance and angle. A CMOS imaging sensor operating at a clock frequency of 27MHz was used in our experiments to produce a video stream at the rate of 75 frames per second. Image component labeling and feature extraction modules were running in parallel having a total latency of 13ms. The MicroBlaze was interfaced with the component labeling and feature extraction modules through Fast Simplex Link (FSL). The latency for computing distance and angle of camera from the reference points was measured to be 2ms on the MicroBlaze, running at 100 MHz clock frequency. In this paper, we present the performance analysis, device utilization and power consumption for the designed system. The FPGA based machine vision system that we propose has high frame speed, low latency and a power consumption that is much lower compared to commercially available smart camera solutions.

  8. Nocturnality constrains morphological and functional diversity in the eyes of reef fishes

    PubMed Central

    2011-01-01

    Background Ambient light levels are often considered to drive the evolution of eye form and function. Diel activity pattern is the main mechanism controlling the visual environment of teleost reef fish, with day-active (diurnal) fish active in well-illuminated conditions, whereas night-active (nocturnal) fish cope with dim light. Physiological optics predicts several specific evolutionary responses to dim-light vision that should be reflected in visual performance features of the eye. Results We analyzed a large comparative dataset on morphological traits of the eyes in 265 species of teleost reef fish in 43 different families. The eye morphology of nocturnal reef teleosts is characterized by a syndrome that indicates better light sensitivity, including large relative eye size, high optical ratio and large, rounded pupils. Improved dim-light image formation comes at the cost of reduced depth of focus and reduction of potential accommodative lens movement. Diurnal teleost reef fish, released from the stringent functional requirements of dim-light vision have much higher morphological and optical diversity than nocturnal species, with large ranges of optical ratio, depth of focus, and lens accommodation. Conclusions Physical characteristics of the environment are an important factor in the evolution and diversification of the vertebrate eye. Both teleost reef fish and terrestrial amniotes meet the functional requirements of dim-light vision with a similar evolutionary response of morphological and optical modifications. The trade-off between improved dim-light vision and reduced optical diversity may be a key factor in explaining the lower trophic diversity of nocturnal reef teleosts. PMID:22098687

  9. Advanced glaucoma: management pearls.

    PubMed

    Gessesse, Girum W; Damji, Karim F

    2013-01-01

    A significant proportion of glaucoma patients present late, particularly in the developing world, and unfortunately, in an advanced stage of the disease. They are at imminent danger of losing remaining vision, and may also be afflicted with various socioeconomic and health challenges. The encounter with such a patient is typically characterized by anxiety/fear and sometimes hopelessness from the patient's perspective. The physician may also feel that they are in a difficult position managing the patient's disease. When dealing with such cases, we suggest a holistic, individualized approach taking into account the 'biopsychosociospiritual' (BPSS) profile of each patient. The BPSS model takes into account relevant ocular as well as systemic biology (factors such as the mechanism of glaucoma, level of intraocular pressure [IOP], rate of progression, life expectancy, general health), psychological considerations (e.g., fear, depression), socio-economic factors and spiritual/cultural values and beliefs before being able to decide with the patient and their care partner(s) what treatment goals should be and how they can best be approached. Treatment for advanced glaucoma can be highly effective, and patients and their care partners should be informed that aggressive IOP lowering to the low teens or even single digits offers the best chance of protecting remaining vision. This can be achieved safely and effectively in most cases with trabeculectomy (including an antimetabolite), and in some cases with medical and/or laser therapy. Vision rehabilitation and psychosocial support should also be considered in order to optimize remaining vision, replace fear with hope as appropriate, and thus improve the overall quality of life.

  10. The Adaptive Optics Summer School Laboratory Activities

    NASA Astrophysics Data System (ADS)

    Ammons, S. M.; Severson, S.; Armstrong, J. D.; Crossfield, I.; Do, T.; Fitzgerald, M.; Harrington, D.; Hickenbotham, A.; Hunter, J.; Johnson, J.; Johnson, L.; Li, K.; Lu, J.; Maness, H.; Morzinski, K.; Norton, A.; Putnam, N.; Roorda, A.; Rossi, E.; Yelda, S.

    2010-12-01

    Adaptive Optics (AO) is a new and rapidly expanding field of instrumentation, yet astronomers, vision scientists, and general AO practitioners are largely unfamiliar with the root technologies crucial to AO systems. The AO Summer School (AOSS), sponsored by the Center for Adaptive Optics, is a week-long course for training graduate students and postdoctoral researchers in the underlying theory, design, and use of AO systems. AOSS participants include astronomers who expect to utilize AO data, vision scientists who will use AO instruments to conduct research, opticians and engineers who design AO systems, and users of high-bandwidth laser communication systems. In this article we describe new AOSS laboratory sessions implemented in 2006-2009 for nearly 250 students. The activity goals include boosting familiarity with AO technologies, reinforcing knowledge of optical alignment techniques and the design of optical systems, and encouraging inquiry into critical scientific questions in vision science using AO systems as a research tool. The activities are divided into three stations: Vision Science, Fourier Optics, and the AO Demonstrator. We briefly overview these activities, which are described fully in other articles in these conference proceedings (Putnam et al., Do et al., and Harrington et al., respectively). We devote attention to the unique challenges encountered in the design of these activities, including the marriage of inquiry-like investigation techniques with complex content and the need to tune depth to a graduate- and PhD-level audience. According to before-after surveys conducted in 2008, the vast majority of participants found that all activities were valuable to their careers, although direct experience with integrated, functional AO systems was particularly beneficial.

  11. Policy implications of trends in Turkey's meat sector with respect to 2023 vision.

    PubMed

    Yavuz, Fahri; Bilgic, Abdulbaki; Terin, Mustafa; Guler, Irfan O

    2013-12-01

    Turkey has become one of the leading emerging economies in the world being second after China as the highest economically growing country with 8.9% economic growth rate in 2010. Forecasting impacts of this development in coming 10 years might have very important policy implications for the meat sector in the framework of 2013 vision of Turkey. In this study, annual time series data which contain several key variables of meat sector in last 26 years (1987-2012) are used to forecast the variables of the coming twelve years (2013-2024) to drive policy implications by considering the impacts of high economic growths, crises and major policy changes. Forecasted future values of the variables for 2023 in the sector are assessed and compared with recent national and international values to drive policy implications. The results show that the economic growth results in the increase in per capita income and thus increased demand for meat seemed to foster the meat sector. Therefore, these macroeconomic indicators need to be better in addition to improvements at micro level for establishing competitive meat sector and thus reaching aimed consumption level of meat. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. A compact CCD-monitored atomic force microscope with optical vision and improved performances.

    PubMed

    Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang

    2013-09-01

    A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.

  13. Preschool children's vision screening in New Zealand: a retrospective evaluation of referral accuracy

    PubMed Central

    Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S

    2015-01-01

    Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622

  14. Do excessive internet use, television viewing and poor lifestyle habits affect low vision in school children?

    PubMed

    Bener, Abdulbari; Al-Mahdi, Huda S; Vachhani, Pankit J; Al-Nufal, Mohammed; Ali, Awab I

    2010-12-01

    The aim of this study is to determine whether excessive internet use, television viewing and the ensuing poor lifestyle habits affect low vision in school children in a rapidly developing country. This is a cross-sectional study and 3000 school students aged between six and 18 years were approached and 2467 (82.2%) students participated. Of the studied school children 12.6 percent had low vision. Most of the low vision school children were in the 6-10 years age group and came from middle income backgrounds (41.8%; p = 0.008). A large proportion of the children with low vision spent ≥ 3 hours per day on the internet (48.2%; p< 0.001) and ≥ 3 hours reclining (62.4%; p < 0.001). A significantly smaller frequency of studied children with low vision participated in each of the reviewed forms of physical activity (p < 0.001) yet a larger proportion consumed fast food (86.8%; p < 0.001). Highly significant positive correlations were found between low vision and BMI, hours spent reclining and on the internet respectively. Blurred vision was the most commonly complained of symptom among the studied children (p < 0.001). The current study suggested a strong association between spending prolonged hours on the computer or TV, fast food eating, poor lifestyle habits and low vision.

  15. Mobility performance in glaucoma.

    PubMed

    Turano, K A; Rubin, G S; Quigley, H A

    1999-11-01

    To determine whether glaucoma affects mobility performance and whether there is a relationship between mobility performance and stage of disease as estimated from vision-function measures. The mobility performance of 47 glaucoma subjects was compared with that of 47 normal-vision subjects who were of similar age. Mobility performance was assessed by the time required to complete an established travel path and the number of mobility incidents. The subjective assessment of falling and fear of falling were also compared. Vision function was assessed by measures of visual acuity, contrast sensitivity, monocular automated threshold perimetry, and suprathreshold; binocular visual fields were assessed with the Esterman test. The glaucoma subjects walked on average 10% more slowly than did the normal-vision subjects. The number of people who experienced bumps, stumbles, or orientation problems was almost twice as high in the glaucoma group than the normal-vision group, but the difference did not reach statistical significance. The difference between groups also was not significant with respect to the number of people who reported falling in the past year (38% for the glaucoma group and 30% for the normal-vision group) or a fear of falling (28% for the glaucoma group and 23% for the normal-vision group). The visual fields assessed with a Humphrey 24-2 test were more highly correlated with walking speed in glaucoma than the visual fields scored by the Esterman scale or than visual acuity or contrast sensitivity. Glaucoma is associated with a modest decrease in mobility performance. Walking speed decreases with severity of the disease as estimated by threshold perimetry.

  16. Commercial Flight Crew Decision-Making during Low-Visibility Approach Operations Using Fused Synthetic/Enhanced Vision Systems

    NASA Technical Reports Server (NTRS)

    Kramer, Lynda J.; Bailey, Randall E.; Prinzel, Lawrence J., III

    2007-01-01

    NASA is investigating revolutionary crew-vehicle interface technologies that strive to proactively overcome aircraft safety barriers that would otherwise constrain the full realization of the next-generation air transportation system. A fixed-based piloted simulation experiment was conducted to evaluate the complementary use of Synthetic and Enhanced Vision technologies. Specific focus was placed on new techniques for integration and/or fusion of Enhanced and Synthetic Vision and its impact within a two-crew flight deck on the crew's decision-making process during low-visibility approach and landing operations. Overall, the experimental data showed that significant improvements in situation awareness, without concomitant increases in workload and display clutter, could be provided by the integration and/or fusion of synthetic and enhanced vision technologies for the pilot-flying and the pilot-not-flying. During non-normal operations, the ability of the crew to handle substantial navigational errors and runway incursions were neither improved nor adversely impacted by the display concepts. The addition of Enhanced Vision may not, unto itself, provide an improvement in runway incursion detection without being specifically tailored for this application. Existing enhanced vision system procedures were effectively used in the crew decision-making process during approach and missed approach operations but having to forcibly transition from an excellent FLIR image to natural vision by 100 ft above field level was awkward for the pilot-flying.

  17. Rotary acceleration of a subject inhibits choice reaction time to motion in peripheral vision

    NASA Technical Reports Server (NTRS)

    Borkenhagen, J. M.

    1974-01-01

    Twelve pilots were tested in a rotation device with visual simulation, alone and in combination with rotary stimulation, in experiments with variable levels of acceleration and variable viewing angles, in a study of the effect of S's rotary acceleration on the choice reaction time for an accelerating target in peripheral vision. The pilots responded to the direction of the visual motion by moving a hand controller to the right or left. Visual-plus-rotary stimulation required a longer choice reaction time, which was inversely related to the level of acceleration and directly proportional to the viewing angle.

  18. Optical and digital pattern recognition; Proceedings of the Meeting, Los Angeles, CA, Jan. 13-15, 1987

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang (Editor); Schenker, Paul (Editor)

    1987-01-01

    The papers presented in this volume provide an overview of current research in both optical and digital pattern recognition, with a theme of identifying overlapping research problems and methodologies. Topics discussed include image analysis and low-level vision, optical system design, object analysis and recognition, real-time hybrid architectures and algorithms, high-level image understanding, and optical matched filter design. Papers are presented on synthetic estimation filters for a control system; white-light correlator character recognition; optical AI architectures for intelligent sensors; interpreting aerial photographs by segmentation and search; and optical information processing using a new photopolymer.

  19. Visual uncertainty influences the extent of an especial skill.

    PubMed

    Czyż, S H; Kwon, O-S; Marzec, J; Styrkowiec, P; Breslin, G

    2015-12-01

    An especial skill in basketball emerges through highly repetitive practice at the 15 ft free throw line. The extent of the role vision plays in the emergence of an especial skill is unknown. We examined the especial skills of ten skilled basketball players in normal and blurred vision conditions where participants wore corrective lenses. As such, we selectively manipulated visual information without affecting the participants' explicit knowledge that they were shooting free throws. We found that shot efficiency was significantly lower in blurred vision conditions as expected, and that the concave shape of shot proficiency function in normal vision conditions became approximately linear in blurred vision conditions. By applying a recently proposed generalization model of especial skills, we suggest that the linearity of shot proficiency function reflects the participants' lesser dependence on especial skill in blurred vision conditions. The findings further characterize the role of visual context in the emergence of an especial skill. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Home Lighting Assessment for Clients With Low Vision

    PubMed Central

    Bhorade, Anjali; Gordon, Mae; Hollingsworth, Holly; Engsberg, Jack E.; Baum, M. Carolyn

    2013-01-01

    OBJECTIVE. The goal was to develop an objective, comprehensive, near-task home lighting assessment for older adults with low vision. METHOD. A home lighting assessment was developed and tested with older adults with low vision. Interrater and test–retest reliability studies were conducted. Clinical utility was assessed by occupational therapists with expertise in low vision rehabilitation. RESULTS. Interrater reliability was high (intraclass correlation coefficient [ICC] = .83–1.0). Test–retest reliability was moderate (ICC = .67). Responses to a Clinical Utility Feedback Form developed for this study indicated that the Home Environment Lighting Assessment (HELA) has strong clinical utility. CONCLUSION. The HELA provides a structured tool to describe the quantitative and qualitative aspects of home lighting environments where near tasks are performed and can be used to plan lighting interventions. The HELA has the potential to affect assessment and intervention practices of rehabilitation professionals in the area of low vision and improve near-task performance of people with low vision. PMID:24195901

  1. Impact of low vision rehabilitation on functional vision performance of children with visual impairment.

    PubMed

    Ganesh, Suma; Sethi, Sumita; Srivastav, Sonia; Chaudhary, Amrita; Arora, Priyanka

    2013-09-01

    To evaluate the impact of low vision rehabilitation on functional vision of children with visual impairment. The LV Prasad-Functional Vision Questionnaire, designed specifically to measure functional performance of visually impaired children of developing countries, was used to assess the level of difficulty in performing various tasks pre and post visual rehabilitation in children with documented visual impairment. Chi-square test was used to assess the impact of rehabilitation intervention on functional vision performance; a P < 0.05 was considered significant. LogMAR visual acuity prior to the introduction of low vision devices (LVDs) was 0.90 ± 0.05 for distance and for near it was 0.61 ± 0.05. After the intervention, the acuities improved significantly for distance (0.2 ± 0.27; P < 0.0001) and near (0.42 ± 0.17; P = 0.001). The most common reported difficulties were related to their academic activities like copying from the blackboard (80%), reading textbook at arm's length (77.2%), and writing along a straight line (77.2%). Absolute raw score of disability pre-LVD was 15.05 which improved to 7.58 post-LVD. An improvement in functional vision post visual rehabilitation was especially found in those activities related to their studying lifestyle like copying from the blackboard (P < 0.0001), reading textbook at arm's length (P < 0.0001), and writing along a straight line (P = 0.003). In our study group, there was a significant improvement in functional vision post visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.

  2. Reliability of Snellen charts for testing visual acuity for driving: prospective study and postal questionnaire

    PubMed Central

    Currie, Zanna; Bhan, Archana; Pepper, Irene

    2000-01-01

    Objectives To assess the ability of patients with binocular 6/9 or 6/12 vision on the Snellen chart (Snellen acuity) to read a number plate at 20.5 m (the required standard for driving) and to determine how health professionals advise such patients about driving. Design Prospective study of patients and postal questionnaire to healthcare professionals. Subjects 50 patients with 6/9 vision and 50 with 6/12 vision and 100 general practitioners, 100 optometrists or opticians, and 100 ophthalmologists. Setting Ophthalmology outpatient clinics in Sheffield. Main outcome measures Ability to read a number plate at 20.5 m and health professionals' advice about driving on the basis of visual acuity. Results 26% of patients with 6/9 vision failed the number plate test, and 34% with 6/12 vision passed it. Of the general practitioners advising patients with 6/9 vision, 76% said the patients could drive, 13% said they should not drive, and 11% were unsure. Of the general practitioners advising patients with 6/12 vision, 21% said the patients could drive, 54% said they should not drive, and 25% were unsure. The level of acuity at which optometrists, opticians, and ophthalmologists would advise drivers against driving ranged from 6/9−2 (ability to read all except two letters on the 6/9 line of the Snellen chart) to less than 6/18. Conclusions Snellen acuity is a poor predictor of an individual's ability to meet the required visual standard for driving. Patients with 6/9 vision or less should be warned that they may fail to meet this standard, but those with 6/12 vision should not be assumed to be below the standard. PMID:11039964

  3. A fuzzy structural matching scheme for space robotics vision

    NASA Technical Reports Server (NTRS)

    Naka, Masao; Yamamoto, Hiromichi; Homma, Khozo; Iwata, Yoshitaka

    1994-01-01

    In this paper, we propose a new fuzzy structural matching scheme for space stereo vision which is based on the fuzzy properties of regions of images and effectively reduces the computational burden in the following low level matching process. Three dimensional distance images of a space truss structural model are estimated using this scheme from stereo images sensed by Charge Coupled Device (CCD) TV cameras.

  4. Development and Validation of a Short-Form Adaptation of the Age-Related Vision Loss Scale: The AVL12

    ERIC Educational Resources Information Center

    Horowitz, Amy; Reinhardt, Joann P.; Raykov, Tenko

    2007-01-01

    This article describes the development and evaluation of a short form of the 24-item Adaptation to Age-Related Vision Loss (AVL) scale. The evaluation provided evidence of the reliability and validity of the short form (the AVL12), for significant interindividual differences at the baseline and for individual-level change in AVL scores over time.…

  5. Effects of the Abnormal Acceleratory Environment of Flight

    DTIC Science & Technology

    1974-12-01

    vision Return of arteriolar pulsa- tion and temporary venous distension Visual failure is a continuum from loss of peripheral vision (grey- out) to...distance); intrathoracic pressure is increased by strong muscular expiratorv efforts against a partially closed glottis; and the contraction of...vigorous skeletal muscular tensing (Valsalva maneuver) can reduce +GZ tolerance and lead to an episode of unconsciousness at extremely low G levels

  6. VLBI2010: Networks and Observing Strategies

    NASA Technical Reports Server (NTRS)

    Petrachenko, Bill; Corey, Brian; Himwich, Ed; Ma, Chopo; Malkin, Zinovy; Niell, Arthur; Shaffer, David; Vandenberg, Nancy

    2004-01-01

    The Observing Strategies Sub-group of IVS's Working Group 3 has been tasked with producing a vision for the following aspects of geodetic VLBI: antenna-network structure and observing strategies; source strength/structure/distribution; frequency bands, RFI; and field system and scheduling. These are high level considerations that have far reaching impact since they significantly influence performance potential and also constrain requirements for a number of other \\VG3 sub-groups. The paper will present the status of the sub-group's work on these topics.

  7. Components of High-Level Vision: A Cognitive Neuroscience Analysis and Accounts of Neurological Syndromes

    DTIC Science & Technology

    1989-02-28

    evidence that only one region of space can be attended to at a time (K. Cave and Kosslyn, in press; Downing and Pinker, 1985; LaBerge , 1983; Larsen...97131 New York NY 10027 Dr Steven Grossberg Or Howard Hock 50 Hyde Street Department of Psychology Newton Highland MA 02161 Florida Atlantic University...hU.m Unterstty University r Georgia Pittsburg* l 71213 Athens GA,- AI2-? Dr Stuart 9lapp Dr Steven W. Keele Department of Psychology Psychology

  8. GBS: Guidance by Semantics-Using High-Level Visual Inference to Improve Vision-Based Mobile Robot Localization

    DTIC Science & Technology

    2015-08-28

    for the scene, and effectively isolates the points on buildings. We are now able to accurately filter in buildings, and filter out the ground, but...brushing hair and hugging. Time Action running kids Agent Motion rolling ball panning camera waves crashing Figure 3: Our work distinguishes inten- tional...action of an unknown agent (the kids in this example) from various other motions, such as the rolling ball, the crashing waves and the background mo

  9. Vision restoration after brain and retina damage: the "residual vision activation theory".

    PubMed

    Sabel, Bernhard A; Henrich-Noack, Petra; Fedorov, Anton; Gall, Carolin

    2011-01-01

    Vision loss after retinal or cerebral visual injury (CVI) was long considered to be irreversible. However, there is considerable potential for vision restoration and recovery even in adulthood. Here, we propose the "residual vision activation theory" of how visual functions can be reactivated and restored. CVI is usually not complete, but some structures are typically spared by the damage. They include (i) areas of partial damage at the visual field border, (ii) "islands" of surviving tissue inside the blind field, (iii) extrastriate pathways unaffected by the damage, and (iv) downstream, higher-level neuronal networks. However, residual structures have a triple handicap to be fully functional: (i) fewer neurons, (ii) lack of sufficient attentional resources because of the dominant intact hemisphere caused by excitation/inhibition dysbalance, and (iii) disturbance in their temporal processing. Because of this resulting activation loss, residual structures are unable to contribute much to everyday vision, and their "non-use" further impairs synaptic strength. However, residual structures can be reactivated by engaging them in repetitive stimulation by different means: (i) visual experience, (ii) visual training, or (iii) noninvasive electrical brain current stimulation. These methods lead to strengthening of synaptic transmission and synchronization of partially damaged structures (within-systems plasticity) and downstream neuronal networks (network plasticity). Just as in normal perceptual learning, synaptic plasticity can improve vision and lead to vision restoration. This can be induced at any time after the lesion, at all ages and in all types of visual field impairments after retinal or brain damage (stroke, neurotrauma, glaucoma, amblyopia, age-related macular degeneration). If and to what extent vision restoration can be achieved is a function of the amount of residual tissue and its activation state. However, sustained improvements require repetitive stimulation which, depending on the method, may take days (noninvasive brain stimulation) or months (behavioral training). By becoming again engaged in everyday vision, (re)activation of areas of residual vision outlasts the stimulation period, thus contributing to lasting vision restoration and improvements in quality of life. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. A differential color flicker test for detecting acquired color vision impairment in multiple sclerosis and diabetic retinopathy.

    PubMed

    Gregori, Bruno; Papazachariadis, Odysseas; Farruggia, Alfonsa; Accornero, Neri

    2011-01-15

    Optic neuritis related to multiple sclerosis and diabetic retinopathy are relatively selective post-retinal and retinal vision disorders. Vision impairment in both conditions is reliably measured by testing critical fusion frequency (CFF). To examine color vision, we measured the CFF in response to red and blue stimuli, and tested CFF values in patients without evident vision impairment. To ensure that differences in CFF values in a given subject depended only on color perception we displayed red and blue flickering stimuli at equal luminance. CFF to red or blue stimuli were compared in patients with medical history of optic neuritis related to multiple sclerosis (post-retinal vision impairment), patients with diabetic retinopathy (retinal vision impairment) and healthy subjects. The test procedure disclosed altered CFF values for red and blue stimuli in both groups of patients studied. The comparison between the two groups disclosed a prevalent CFF impairment for red stimuli in patients with optic neuritis related to multiple sclerosis and for blue stimuli in patients with diabetic retinopathy. The differential color flicker test appears highly accurate in detecting color vision impairment. Comparison of the two color CFFs differentiates retinal from post-retinal visual disorders. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Perceptual Learning Improves Adult Amblyopic Vision Through Rule-Based Cognitive Compensation

    PubMed Central

    Zhang, Jun-Yun; Cong, Lin-Juan; Klein, Stanley A.; Levi, Dennis M.; Yu, Cong

    2014-01-01

    Purpose. We investigated whether perceptual learning in adults with amblyopia could be enabled to transfer completely to an orthogonal orientation, which would suggest that amblyopic perceptual learning results mainly from high-level cognitive compensation, rather than plasticity in the amblyopic early visual brain. Methods. Nineteen adults (mean age = 22.5 years) with anisometropic and/or strabismic amblyopia were trained following a training-plus-exposure (TPE) protocol. The amblyopic eyes practiced contrast, orientation, or Vernier discrimination at one orientation for six to eight sessions. Then the amblyopic or nonamblyopic eyes were exposed to an orthogonal orientation via practicing an irrelevant task. Training was first performed at a lower spatial frequency (SF), then at a higher SF near the cutoff frequency of the amblyopic eye. Results. Perceptual learning was initially orientation specific. However, after exposure to the orthogonal orientation, learning transferred to an orthogonal orientation completely. Reversing the exposure and training order failed to produce transfer. Initial lower SF training led to broad improvement of contrast sensitivity, and later higher SF training led to more specific improvement at high SFs. Training improved visual acuity by 1.5 to 1.6 lines (P < 0.001) in the amblyopic eyes with computerized tests and a clinical E acuity chart. It also improved stereoacuity by 53% (P < 0.001). Conclusions. The complete transfer of learning suggests that perceptual learning in amblyopia may reflect high-level learning of rules for performing a visual discrimination task. These rules are applicable to new orientations to enable learning transfer. Therefore, perceptual learning may improve amblyopic vision mainly through rule-based cognitive compensation. PMID:24550359

  12. Putting Automated Visual Inspection Systems To Work On The Factory Floor: What's Missing?

    NASA Astrophysics Data System (ADS)

    Waltz, Frederick M.; Snyder, Michael A.; Batchelor, Bruce G.

    1990-02-01

    Machine vision systems and other automated visual inspection (AVI) systems have been proving their usefulness in factories for more than a decade. In spite of this, the number of installed systems is far below the number that could profitably be employed. In the opinion of the authors, the primary reason for this is the high cost of customizing vision systems to meet applications requirements. A three-part approach to this problem has proven to be useful: 1. A multi-phase paradigm for customer interaction, system specification, system development, and system installation; 2. A powerful and easy-to-use system development environment, including a a flexible laboratory lighting setup, plus software-based tools to assist in the design of image acquisition systems, b. an image processing environment with a very large repertoire of image processing and feature extraction operations and an easy-to-use command interpreter having macro capabilities, and c. an image analysis environment with high-level constructs, a flexible and powerful syntax, and a "seamless" interface to the image processing level; and 3. A moderately-priced high-speed "target" system fully compatible with the development environment, so that algorithms developed thereon can be transferred directly to the factory environment without further development costs or reprogramming. Items 1 and 2 are covered in other papers1,23,4,5 and are touched on here only briefly. Item 3 is the main subject of this paper. Our major motivation in presenting this paper is to offer suggestions to vendors developing commercial boards and systems, in hopes that the special needs of industrial inspection can be met.

  13. Perceptual learning improves adult amblyopic vision through rule-based cognitive compensation.

    PubMed

    Zhang, Jun-Yun; Cong, Lin-Juan; Klein, Stanley A; Levi, Dennis M; Yu, Cong

    2014-04-01

    We investigated whether perceptual learning in adults with amblyopia could be enabled to transfer completely to an orthogonal orientation, which would suggest that amblyopic perceptual learning results mainly from high-level cognitive compensation, rather than plasticity in the amblyopic early visual brain. Nineteen adults (mean age = 22.5 years) with anisometropic and/or strabismic amblyopia were trained following a training-plus-exposure (TPE) protocol. The amblyopic eyes practiced contrast, orientation, or Vernier discrimination at one orientation for six to eight sessions. Then the amblyopic or nonamblyopic eyes were exposed to an orthogonal orientation via practicing an irrelevant task. Training was first performed at a lower spatial frequency (SF), then at a higher SF near the cutoff frequency of the amblyopic eye. Perceptual learning was initially orientation specific. However, after exposure to the orthogonal orientation, learning transferred to an orthogonal orientation completely. Reversing the exposure and training order failed to produce transfer. Initial lower SF training led to broad improvement of contrast sensitivity, and later higher SF training led to more specific improvement at high SFs. Training improved visual acuity by 1.5 to 1.6 lines (P < 0.001) in the amblyopic eyes with computerized tests and a clinical E acuity chart. It also improved stereoacuity by 53% (P < 0.001). The complete transfer of learning suggests that perceptual learning in amblyopia may reflect high-level learning of rules for performing a visual discrimination task. These rules are applicable to new orientations to enable learning transfer. Therefore, perceptual learning may improve amblyopic vision mainly through rule-based cognitive compensation.

  14. Adaptive evolution of the myo6 gene in old world fruit bats (family: pteropodidae).

    PubMed

    Shen, Bin; Han, Xiuqun; Jones, Gareth; Rossiter, Stephen J; Zhang, Shuyi

    2013-01-01

    Myosin VI (encoded by the Myo6 gene) is highly expressed in the inner and outer hair cells of the ear, retina, and polarized epithelial cells such as kidney proximal tubule cells and intestinal enterocytes. The Myo6 gene is thought to be involved in a wide range of physiological functions such as hearing, vision, and clathrin-mediated endocytosis. Bats (Chiroptera) represent one of the most fascinating mammal groups for molecular evolutionary studies of the Myo6 gene. A diversity of specialized adaptations occur among different bat lineages, such as echolocation and associated high-frequency hearing in laryngeal echolocating bats, large eyes and a strong dependence on vision in Old World fruit bats (Pteropodidae), and specialized high-carbohydrate but low-nitrogen diets in both Old World and New World fruit bats (Phyllostomidae). To investigate what role(s) the Myo6 gene might fulfill in bats, we sequenced the coding region of the Myo6 gene in 15 bat species and used molecular evolutionary analyses to detect evidence of positive selection in different bat lineages. We also conducted real-time PCR assays to explore the expression levels of Myo6 in a range of tissues from three representative bat species. Molecular evolutionary analyses revealed that the Myo6 gene, which was widely considered as a hearing gene, has undergone adaptive evolution in the Old World fruit bats which lack laryngeal echolocation and associated high-frequency hearing. Real-time PCR showed the highest expression level of the Myo6 gene in the kidney among ten tissues examined in three bat species, indicating an important role for this gene in kidney function. We suggest that Myo6 has undergone adaptive evolution in Old World fruit bats in relation to receptor-mediated endocytosis for the preservation of protein and essential nutrients.

  15. Vision-The Strategic Leader Imperative

    DTIC Science & Technology

    1998-05-07

    Habits of Highly Effective People . New York: Simon and Schuster, 1989. Estes, Howell M., III. United States Space Command: Vision For 2020...James C. and Jerry I. Porras. Built to Last: Successful Habits of Visionary Companies. New York: Harper Business, 1994. Covey, Stephen R. The 7

  16. Computer vision applied to herbarium specimens of German trees: testing the future utility of the millions of herbarium specimen images for automated identification.

    PubMed

    Unger, Jakob; Merhof, Dorit; Renner, Susanne

    2016-11-16

    Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.

  17. Signal coding in cockroach photoreceptors is tuned to dim environments.

    PubMed

    Heimonen, K; Immonen, E-V; Frolov, R V; Salmela, I; Juusola, M; Vähäsöyrinki, M; Weckström, M

    2012-11-01

    In dim light, scarcity of photons typically leads to poor vision. Nonetheless, many animals show visually guided behavior with dim environments. We investigated the signaling properties of photoreceptors of the dark active cockroach (Periplaneta americana) using intracellular and whole-cell patch-clamp recordings to determine whether they show selective functional adaptations to dark. Expectedly, dark-adapted photoreceptors generated large and slow responses to single photons. However, when light adapted, responses of both phototransduction and the nontransductive membrane to white noise (WN)-modulated stimuli remained slow with corner frequencies ~20 Hz. This promotes temporal integration of light inputs and maintains high sensitivity of vision. Adaptive changes in dynamics were limited to dim conditions. Characteristically, both step and frequency responses stayed effectively unchanged for intensities >1,000 photons/s/photoreceptor. A signal-to-noise ratio (SNR) of the light responses was transiently higher at frequencies <5 Hz for ~5 s after light onset but deteriorated to a lower value upon longer stimulation. Naturalistic light stimuli, as opposed to WN, evoked markedly larger responses with higher SNRs at low frequencies. This allowed realistic estimates of information transfer rates, which saturated at ~100 bits/s at low-light intensities. We found, therefore, selective adaptations beneficial for vision in dim environments in cockroach photoreceptors: large amplitude of single-photon responses, constant high level of temporal integration of light inputs, saturation of response properties at low intensities, and only transiently efficient encoding of light contrasts. The results also suggest that the sources of the large functional variability among different photoreceptors reside mostly in phototransduction processes and not in the properties of the nontransductive membrane.

  18. A self-learning camera for the validation of highly variable and pseudorandom patterns

    NASA Astrophysics Data System (ADS)

    Kelley, Michael

    2004-05-01

    Reliable and productive manufacturing operations have depended on people to quickly detect and solve problems whenever they appear. Over the last 20 years, more and more manufacturing operations have embraced machine vision systems to increase productivity, reliability and cost-effectiveness, including reducing the number of human operators required. Although machine vision technology has long been capable of solving simple problems, it has still not been broadly implemented. The reason is that until now, no machine vision system has been designed to meet the unique demands of complicated pattern recognition. The ZiCAM family was specifically developed to be the first practical hardware to meet these needs. To be able to address non-traditional applications, the machine vision industry must include smart camera technology that meets its users" demands for lower costs, better performance and the ability to address applications of irregular lighting, patterns and color. The next-generation smart cameras will need to evolve as a fundamentally different kind of sensor, with new technology that behaves like a human but performs like a computer. Neural network based systems, coupled with self-taught, n-space, non-linear modeling, promises to be the enabler of the next generation of machine vision equipment. Image processing technology is now available that enables a system to match an operator"s subjectivity. A Zero-Instruction-Set-Computer (ZISC) powered smart camera allows high-speed fuzzy-logic processing, without the need for computer programming. This can address applications of validating highly variable and pseudo-random patterns. A hardware-based implementation of a neural network, Zero-Instruction-Set-Computer, enables a vision system to "think" and "inspect" like a human, with the speed and reliability of a machine.

  19. An inkjet vision measurement technique for high-frequency jetting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Kye-Si, E-mail: kskwon@sch.ac.kr; Jang, Min-Hyuck; Park, Ha Yeong

    2014-06-15

    Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation ofmore » high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance.« less

  20. Sharpening coarse-to-fine stereo vision by perceptual learning: asymmetric transfer across the spatial frequency spectrum

    PubMed Central

    Tran, Truyet T.; Craven, Ashley P.; Leung, Tsz-Wing; Chat, Sandy W.; Levi, Dennis M.

    2016-01-01

    Neurons in the early visual cortex are finely tuned to different low-level visual features, forming a multi-channel system analysing the visual image formed on the retina in a parallel manner. However, little is known about the potential ‘cross-talk’ among these channels. Here, we systematically investigated whether stereoacuity, over a large range of target spatial frequencies, can be enhanced by perceptual learning. Using narrow-band visual stimuli, we found that practice with coarse (low spatial frequency) targets substantially improves performance, and that the improvement spreads from coarse to fine (high spatial frequency) three-dimensional perception, generalizing broadly across untrained spatial frequencies and orientations. Notably, we observed an asymmetric transfer of learning across the spatial frequency spectrum. The bandwidth of transfer was broader when training was at a high spatial frequency than at a low spatial frequency. Stereoacuity training is most beneficial when trained with fine targets. This broad transfer of stereoacuity learning contrasts with the highly specific learning reported for other basic visual functions. We also revealed strategies to boost learning outcomes ‘beyond-the-plateau’. Our investigations contribute to understanding the functional properties of the network subserving stereovision. The ability to generalize may provide a key principle for restoring impaired binocular vision in clinical situations. PMID:26909178

  1. Analysis of the resistive network in a bio-inspired CMOS vision chip

    NASA Astrophysics Data System (ADS)

    Kong, Jae-Sung; Sung, Dong-Kyu; Hyun, Hyo-Young; Shin, Jang-Kyoo

    2007-12-01

    CMOS vision chips for edge detection based on a resistive circuit have recently been developed. These chips help develop neuromorphic systems with a compact size, high speed of operation, and low power dissipation. The output of the vision chip depends dominantly upon the electrical characteristics of the resistive network which consists of a resistive circuit. In this paper, the body effect of the MOSFET for current distribution in a resistive circuit is discussed with a simple model. In order to evaluate the model, two 160×120 CMOS vision chips have been fabricated by using a standard CMOS technology. The experimental results have been nicely matched with our prediction.

  2. Some Examples Of Image Warping For Low Vision Prosthesis

    NASA Astrophysics Data System (ADS)

    Juday, Richard D.; Loshin, David S.

    1988-08-01

    NASA and Texas Instruments have developed an image processor, the Programmable Remapper 1, for certain functions in machine vision. The Remapper performs a highly arbitrary geometric warping of an image at video rate. It might ultimately be shrunk to a size and cost that could allow its use in a low-vision prosthesis. We have developed coordinate warpings for retinitis pigmentosa (tunnel vision) and for maculapathy (loss of central field) that are intended to make best use of the patient's remaining viable retina. The rationales and mathematics are presented for some warpings that we will try in clinical studies using the Remapper's prototype. (Recorded video imagery was shown at the conference for the maculapathy remapping.

  3. TMS effects on subjective and objective measures of vision: stimulation intensity and pre- versus post-stimulus masking.

    PubMed

    de Graaf, Tom A; Cornelsen, Sonja; Jacobs, Christianne; Sack, Alexander T

    2011-12-01

    Transcranial magnetic stimulation (TMS) can be used to mask visual stimuli, disrupting visual task performance or preventing visual awareness. While TMS masking studies generally fix stimulation intensity, we hypothesized that varying the intensity of TMS pulses in a masking paradigm might inform several ongoing debates concerning TMS disruption of vision as measured subjectively versus objectively, and pre-stimulus (forward) versus post-stimulus (backward) TMS masking. We here show that both pre-stimulus TMS pulses and post-stimulus TMS pulses could strongly mask visual stimuli. We found no dissociations between TMS effects on the subjective and objective measures of vision for any masking window or intensity, ruling out the option that TMS intensity levels determine whether dissociations between subjective and objective vision are obtained. For the post-stimulus time window particularly, we suggest that these data provide new constraints for (e.g. recurrent) models of vision and visual awareness. Finally, our data are in line with the idea that pre-stimulus masking operates differently from conventional post-stimulus masking. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Color Vision Losses in Autism Spectrum Disorders

    PubMed Central

    Zachi, Elaine C.; Costa, Thiago L.; Barboni, Mirella T. S.; Costa, Marcelo F.; Bonci, Daniela M. O.; Ventura, Dora F.

    2017-01-01

    Autism spectrum disorders (ASDs) are neurodevelopmental conditions characterized by impairments in social/communication abilities and restricted behaviors. The present study aims to examine color vision discrimination in ASD children and adolescents without intellectual disability. The participants were also subdivided in order to compare color vision thresholds of autistic participants and those who achieved diagnostic criteria for Asperger Syndrome (AS). Nine subjects with autism, 11 participants with AS and 36 typically developing children and adolescents participated in the study. Color vision was assessed by the Cambridge Color Test (CCT). The Trivector protocol was administered to determine color discrimination thresholds along the protan, deutan, and tritan color confusion lines. Data from ASD participants were compared to tolerance limits for 90% of the population with 90% probability obtained from controls thresholds. Of the 20 ASD individuals examined, 6 (30%) showed color vision losses. Elevated color discrimination thresholds were found in 3/9 participants with autism and in 3/11 AS participants. Diffuse and tritan deficits were found. Mechanisms for chromatic losses may be either at the retinal level and/or reflect reduced cortical integration. PMID:28713324

  5. Effect of glare on reaction time for peripheral vision at mesopic adaptation.

    PubMed

    Aguirre, Rolando C; Colombo, Elisa M; Barraza, José F

    2011-10-01

    When a bright light is present in the field of view, visibility is dramatically reduced. Many studies have investigated the effect of glare on visibility considering foveal vision. However, the effects on peripheral vision have received little attention. In a previous work [J. Opt. Soc. Am. A 25, 1790 (2008)], we showed that the effect of glare on reaction time (RT) for foveal vision at mesopic adaptation depends on the stimulus spatial frequency. In this work, we extend this study to peripheral vision. We measured the RT of achromatic sinusoidal gratings as a function of contrast for a range of spatial frequency, and eccentricity, and for two glare levels, in addition to the no-glare condition. Data were fitted with Piéron's law, following a linear relationship. We found that glare increases the slope of these lines for all conditions. These slopes seem to depend critically on eccentricity for 4 cycles/degree (c/deg), but not for 1 and 2 c/deg. We explain our results in terms of the contrast sensitivity (gain) of the underlying detection mechanisms.

  6. Low Vision Rehabilitation for Adult African Americans in Two Settings.

    PubMed

    Draper, Erin M; Feng, Rui; Appel, Sarah D; Graboyes, Marcy; Engle, Erin; Ciner, Elise B; Ellenberg, Jonas H; Stambolian, Dwight

    2016-07-01

    The Vision Rehabilitation for African Americans with Central Vision Impairment (VISRAC) study is a demonstration project evaluating how modifications in vision rehabilitation can improve the use of functional vision. Fifty-five African Americans 40 years of age and older with central vision impairment were randomly assigned to receive either clinic-based (CB) or home-based (HB) low vision rehabilitation services. Forty-eight subjects completed the study. The primary outcome was the change in functional vision in activities of daily living, as assessed with the Veteran's Administration Low-Vision Visual Function Questionnaire (VFQ-48). This included scores for overall visual ability and visual ability domains (reading, mobility, visual information processing, and visual motor skills). Each score was normalized into logit estimates by Rasch analysis. Linear regression models were used to compare the difference in the total score and each domain score between the two intervention groups. The significance level for each comparison was set at 0.05. Both CB and HB groups showed significant improvement in overall visual ability at the final visit compared with baseline. The CB group showed greater improvement than the HB group (mean of 1.28 vs. 0.87 logits change), though the group difference is not significant (p = 0.057). The CB group visual motor skills score showed significant improvement over the HB group score (mean of 3.30 vs. 1.34 logits change, p = 0.044). The differences in improvement of the reading and visual information processing scores were not significant (p = 0.054 and p = 0.509) between groups. Neither group had significant improvement in the mobility score, which was not part of the rehabilitation program. Vision rehabilitation is effective for this study population regardless of location. Possible reasons why the CB group performed better than the HB group include a number of psychosocial factors as well as the more standardized distraction-free work environment within the clinic setting.

  7. Blue-yellow colour vision impairment and cognitive deficits in occasional and dependent stimulant users.

    PubMed

    Hulka, Lea M; Wagner, Michael; Preller, Katrin H; Jenni, Daniela; Quednow, Boris B

    2013-04-01

    Specific blue-yellow colour vision impairment has been reported in dependent cocaine users and it was postulated that drug-induced changes in retinal dopamine neurotransmission are responsible. However, it is unclear whether these changes are confined to chronic cocaine users, whether they are specific for dopaminergic stimulants such as cocaine and amphetamine and whether they are related to cognitive functions such as working memory, encoding and consolidation. In 47 occasional and 29 dependent cocaine users, 23 MDMA (commonly known as 'ecstasy') users and 47 stimulant-naive controls, colour vision discrimination was measured with the Lanthony Desaturated Panel D-15 Test and memory performance with the Auditory Verbal Learning Test. Both occasional and dependent cocaine users showed higher colour confusion indices than controls. Users of the serotonergic stimulant MDMA (26%), occasional (30%) and dependent cocaine users (34%) exhibited more frequent blue-yellow colour vision disorders compared to controls (9%). Inferior performance of MDMA users was caused by a subgroup with high amphetamine co-use (55%), while MDMA use alone was not associated with decreased blue-yellow discrimination (0%). Cognitive performance was worse in cocaine users with colour vision disorder compared to users and controls with intact colour vision and both colour vision impairment and cognitive deficits were related to cocaine use. Occasional cocaine and amphetamine use might induce blue-yellow colour vision impairment, whereas the serotonergic stimulant MDMA does not impair colour vision. The association between colour vision impairment and cognitive deficits in cocaine users may reflect that retinal and cerebral dopamine alterations are linked to a certain degree.

  8. A Vision Too Far? Mapping the Space for a High Skills Project in the UK

    ERIC Educational Resources Information Center

    Lloyd, Caroline; Payne, Jonathan

    2005-01-01

    Although the current Labour government is committed to developing the UK as a high skills society, there is much confusion as what such a society might look like and from where it might draw its inspiration. Some academic commentators have also expressed the need for a clearer vision of the kind of society to which the UK might choose to head for…

  9. Effects of job-related stress and burnout on asthenopia among high-tech workers.

    PubMed

    Ostrovsky, Anat; Ribak, Joseph; Pereg, Avihu; Gaton, Dan

    2012-01-01

    Eye- and vision-related symptoms are the most frequent health problems among computer users. The findings of eye strain, tired eyes, eye irritation, burning sensation, redness, blurred vision and double vision, when appearing together, have recently been termed 'computer vision syndrome', or asthenopia. To examine the frequency and intensity of asthenopia among individuals employed in research and development departments of high-tech firms and the effects of job stress and burnout on ocular complaints, this study included 106 subjects, 42 high-tech workers (study group) and 64 bank employees (control group). All participants completed self-report questionnaires covering demographics, asthenopia, satisfaction with work environmental conditions, job-related stress and burnout. There was a significant between-group difference in the intensity of asthenopia, but not in its frequency. Burnout appeared to be a significant contributing factor to the intensity and frequency of asthenopia. This study shows that burnout is a significant factor in asthenopic complaints in high-tech workers. This manuscript analyses the effects of psychological environmental factors, such as job stress and burnout, on ocular complaints at the workplace of computer users. The findings may have an ergonomic impact on how to improve health, safety and comfort of the working environment among computer users, for better perception of the job environment, efficacy and production.

  10. The visibility of controls and labels on electronic devices and their suitability for people with impaired vision.

    PubMed

    Tan, Hsuan; Boon, Mei Ying; Dain, Stephen J

    2014-01-01

    People with low vision complain of difficulty operating controls on electronic appliances and equipment which suggests that the readability of controls and their labels is below their ability. To investigate whether electronic appliances available today are designed with controls of sufficient size (at least 6/18 Snellen VA) and contrast (at least 30%) to facilitate identification and use by people with low vision. Controls and labels of electronic appliances for sale in retail stores in Singapore (January, February 2012) and a sample of domestic appliances in Sydney, Australia (October, November of 2011) were evaluated in terms of high- and low- importance in function, size and contrast (luminance and colour difference). Labels and controls of 96 electronic appliances were evaluated. All controls were of sufficient size but 22% (26/117) of high- and 27% (12/44) of low-importance controls measured had insufficient luminance contrast. 79% (152/192) of high- and 46% (24/52) of low-importance labels were of insufficient size. 17% (26/160) of the high- and 0.03% (1/33) of low-importance labels had insufficient luminance contrast. Most controls and labels of recently available electronic appliances can cause problems for operability in people with low vision.

  11. Utility of the Care Dependency Scale in predicting care needs and health risks of elderly patients admitted to a geriatric unit: a cross-sectional study of 200 consecutive patients.

    PubMed

    Doroszkiewicz, Halina; Sierakowska, Matylda; Muszalik, Marta

    2018-01-01

    The aim of the study was to evaluate the usefulness of the Polish version of the Care Dependency Scale (CDS) in predicting care needs and health risks of elderly patients admitted to a geriatric unit. This was a cross-sectional study of 200 geriatric patients aged ≥60 years, chronologically admitted to a geriatrics unit in Poland. The study was carried out using the Polish version of the CDS questionnaire to evaluate biopsychosocial needs and the level of care dependency. The mean age of the participating geriatric patients was 81.8±6.6. The mean result of the sum of the CDS index for all the participants was 55.3±15.1. Detailed analysis of the results of evaluation of the respondents' functional condition showed statistically significant differences in the levels of care dependency. Evaluation of the patients' physical performance in terms of the ability to do basic activities of daily living (ADL) and instrumental ADL (I-ADL) showed statistically significant differences between the levels of care dependency. Patients with high dependency were more often prone to pressure ulcers - 13.1±3.3, falls (87.2%), poorer emotional state - 6.9±3.6, mental function - 5.1±2.8, and more often problems with locomotion, vision, and hearing. The results showed that locomotive disability, depression, advanced age, and problem with vision and hearing are connected with increasing care dependency. CDS evaluation of each admitted geriatric patient enables us to predict the care needs and health risks that need to be reduced and the disease states to be improved. CDS evaluation should be accompanied by the use of other instruments and assessments to evaluate pressure ulcer risk, fall risk, and actions toward the improvement of subjective well-being, as well as correction of vision and hearing problems where possible and assistive devices for locomotion.

  12. Gaze shifts during dual-tasking stair descent.

    PubMed

    Miyasike-daSilva, Veronica; McIlroy, William E

    2016-11-01

    To investigate the role of vision in stair locomotion, young adults descended a seven-step staircase during unrestricted walking (CONTROL), and while performing a concurrent visual reaction time (RT) task displayed on a monitor. The monitor was located at either 3.5 m (HIGH) or 0.5 m (LOW) above ground level at the end of the stairway, which either restricted (HIGH) or facilitated (LOW) the view of the stairs in the lower field of view as participants walked downstairs. Downward gaze shifts (recorded with an eye tracker) and gait speed were significantly reduced in HIGH and LOW compared with CONTROL. Gaze and locomotor behaviour were not different between HIGH and LOW. However, inter-individual variability increased in HIGH, in which participants combined different response characteristics including slower walking, handrail use, downward gaze, and/or increasing RTs. The fastest RTs occurred in the midsteps (non-transition steps). While gait and visual task performance were not statistically different prior to the top and bottom transition steps, gaze behaviour and RT were more variable prior to transition steps in HIGH. This study demonstrated that, in the presence of a visual task, people do not look down as often when walking downstairs and require minimum adjustments provided that the view of the stairs is available in the lower field of view. The middle of the stairs seems to require less from executive function, whereas visual attention appears a requirement to detect the last transition via gaze shifts or peripheral vision.

  13. A computer architecture for intelligent machines

    NASA Technical Reports Server (NTRS)

    Lefebvre, D. R.; Saridis, G. N.

    1991-01-01

    The Theory of Intelligent Machines proposes a hierarchical organization for the functions of an autonomous robot based on the Principle of Increasing Precision With Decreasing Intelligence. An analytic formulation of this theory using information-theoretic measures of uncertainty for each level of the intelligent machine has been developed in recent years. A computer architecture that implements the lower two levels of the intelligent machine is presented. The architecture supports an event-driven programming paradigm that is independent of the underlying computer architecture and operating system. Details of Execution Level controllers for motion and vision systems are addressed, as well as the Petri net transducer software used to implement Coordination Level functions. Extensions to UNIX and VxWorks operating systems which enable the development of a heterogeneous, distributed application are described. A case study illustrates how this computer architecture integrates real-time and higher-level control of manipulator and vision systems.

  14. USAF Summer Faculty Research Program. 1981 Research Reports. Volume I.

    DTIC Science & Technology

    1981-10-01

    Kent, OH 44242 (216) 672-2816 Dr. Martin D. Altschuler Degree: PhD, Physics and Astronomy, 1964 Associate Professor Specialty: Robot Vision, Surface...line inspection and control, computer- aided manufacturing, robot vision, mapping of machine parts and castings, etc. The technique we developed...posture, reduced healing time and bacteria level, and improved capacity for work endurance and efficiency. 1 ,2𔃽 Federal agencies, such as the FDA and

  15. The Effect of Expansion of Vision Span on Reading Speed: A Case Study of EFL Major Students at King Khalid University

    ERIC Educational Resources Information Center

    Kana'an, Basim Hamdan Ibrahim; Rab, Salahud Din Abdul; Siddiqui, Ahlullah

    2014-01-01

    The objective of the study is to demonstrate how and to what extent the expansion of vision span could be a decisive factor in enhancing the reading speed of EFL major students in the English Department at King Khalid University while maintaining their previous level of comprehension. The reading speed of students in the English Department at KKU…

  16. Neuroimaging of amblyopia and binocular vision: a review

    PubMed Central

    Joly, Olivier; Frankó, Edit

    2014-01-01

    Amblyopia is a cerebral visual impairment considered to derive from abnormal visual experience (e.g., strabismus, anisometropia). Amblyopia, first considered as a monocular disorder, is now often seen as a primarily binocular disorder resulting in more and more studies examining the binocular deficits in the patients. The neural mechanisms of amblyopia are not completely understood even though they have been investigated with electrophysiological recordings in animal models and more recently with neuroimaging techniques in humans. In this review, we summarize the current knowledge about the brain regions that underlie the visual deficits associated with amblyopia with a focus on binocular vision using functional magnetic resonance imaging. The first studies focused on abnormal responses in the primary and secondary visual areas whereas recent evidence shows that there are also deficits at higher levels of the visual pathways within the parieto-occipital and temporal cortices. These higher level areas are part of the cortical network involved in 3D vision from binocular cues. Therefore, reduced responses in these areas could be related to the impaired binocular vision in amblyopic patients. Promising new binocular treatments might at least partially correct the activation in these areas. Future neuroimaging experiments could help to characterize the brain response changes associated with these treatments and help devise them. PMID:25147511

  17. Integrated navigation, flight guidance, and synthetic vision system for low-level flight

    NASA Astrophysics Data System (ADS)

    Mehler, Felix E.

    2000-06-01

    Future military transport aircraft will require a new approach with respect to the avionics suite to fulfill an ever-changing variety of missions. The most demanding phases of these mission are typically the low level flight segments, including tactical terrain following/avoidance,payload drop and/or board autonomous landing at forward operating strips without ground-based infrastructure. As a consequence, individual components and systems must become more integrated to offer a higher degree of reliability, integrity, flexibility and autonomy over existing systems while reducing crew workload. The integration of digital terrain data not only introduces synthetic vision into the cockpit, but also enhances navigation and guidance capabilities. At DaimlerChrysler Aerospace AG Military Aircraft Division (Dasa-M), an integrated navigation, flight guidance and synthetic vision system, based on digital terrain data, has been developed to fulfill the requirements of the Future Transport Aircraft (FTA). The fusion of three independent navigation sensors provides a more reliable and precise solution to both the 4D-flight guidance and the display components, which is comprised of a Head-up and a Head-down Display with synthetic vision. This paper will present the system, its integration into the DLR's VFW 614 Advanced Technology Testing Aircraft System (ATTAS) and the results of the flight-test campaign.

  18. Neuroimaging of amblyopia and binocular vision: a review.

    PubMed

    Joly, Olivier; Frankó, Edit

    2014-01-01

    Amblyopia is a cerebral visual impairment considered to derive from abnormal visual experience (e.g., strabismus, anisometropia). Amblyopia, first considered as a monocular disorder, is now often seen as a primarily binocular disorder resulting in more and more studies examining the binocular deficits in the patients. The neural mechanisms of amblyopia are not completely understood even though they have been investigated with electrophysiological recordings in animal models and more recently with neuroimaging techniques in humans. In this review, we summarize the current knowledge about the brain regions that underlie the visual deficits associated with amblyopia with a focus on binocular vision using functional magnetic resonance imaging. The first studies focused on abnormal responses in the primary and secondary visual areas whereas recent evidence shows that there are also deficits at higher levels of the visual pathways within the parieto-occipital and temporal cortices. These higher level areas are part of the cortical network involved in 3D vision from binocular cues. Therefore, reduced responses in these areas could be related to the impaired binocular vision in amblyopic patients. Promising new binocular treatments might at least partially correct the activation in these areas. Future neuroimaging experiments could help to characterize the brain response changes associated with these treatments and help devise them.

  19. Visual Search in the Real World: Color Vision Deficiency Affects Peripheral Guidance, but Leaves Foveal Verification Largely Unaffected.

    PubMed

    Kugler, Günter; 't Hart, Bernard M; Kohlbecher, Stefan; Bartl, Klaus; Schumann, Frank; Einhäuser, Wolfgang; Schneider, Erich

    2015-01-01

    People with color vision deficiencies report numerous limitations in daily life, restricting, for example, their access to some professions. However, they use basic color terms systematically and in a similar manner as people with normal color vision. We hypothesize that a possible explanation for this discrepancy between color perception and behavioral consequences might be found in the gaze behavior of people with color vision deficiency. A group of participants with color vision deficiencies and a control group performed several search tasks in a naturalistic setting on a lawn. All participants wore a mobile eye-tracking-driven camera with a high foveal image resolution (EyeSeeCam). Search performance as well as fixations of objects of different colors were examined. Search performance was similar in both groups in a color-unrelated search task as well as in a search for yellow targets. While searching for red targets, participants with color vision deficiencies exhibited a strongly degraded performance. This was closely matched by the number of fixations on red objects shown by the two groups. Importantly, once they fixated a target, participants with color vision deficiencies exhibited only few identification errors. In contrast to controls, participants with color vision deficiencies are not able to enhance their search for red targets on a (green) lawn by an efficient guiding mechanism. The data indicate that the impaired guiding is the main influence on search performance, while foveal identification (verification) is largely unaffected by the color vision deficiency.

  20. Outcomes of Endoscopic Realignment of Pelvic Fracture Associated Urethral Injuries at a Level 1 Trauma Center

    PubMed Central

    Leddy, Laura S.; Vanni, Alex J.; Wessells, Hunter; Voelzke, Bryan B.

    2012-01-01

    Purpose We examined the success of early endoscopic realignment of pelvic fracture associated urethral injury after blunt pelvic trauma. Materials and Methods A retrospective review was performed of patients with pelvic fracture associated urethral injury who underwent early endoscopic realignment using a retrograde or retrograde/antegrade approach from 2004 to 2010 at a Level 1 trauma center. Followup consisted of uroflowmetry, post-void residual and cystoscopic evaluation. Failure of early endoscopic realignment was defined as patients requiring urethral dilation, direct vision internal urethrotomy, posterior urethroplasty or self-catheterization after initial urethral catheter removal. Results A total of 19 consecutive patients (mean age 38 years) with blunt pelvic fracture associated urethral injury underwent early endoscopic realignment. Twelve cases of complete urethral disruption, 4 of incomplete disruption and 3 of indeterminate status were noted. Mean time to realignment was 2 days and mean duration of urethral catheterization after realignment was 53 days. One patient was lost to followup after early endoscopic realignment. Using an intent to treat analysis early endoscopic realignment failed in 15 of 19 patients (78.9%). Mean time to early endoscopic realignment failure after catheter removal was 79 days. The cases of early endoscopic realignment failure were managed with posterior urethroplasty (8), direct vision internal urethrotomy (3) and direct vision internal urethrotomy followed by posterior urethroplasty (3). Mean followup for the 4 patients considered to have undergone successful early endoscopic realignment was 2.1 years. Conclusions Early endoscopic realignment after blunt pelvic fracture associated urethral injury results in high rates of symptomatic urethral stricture requiring further operative treatment. Close followup after initial catheter removal is warranted, as the mean time to failure after early endoscopic realignment was 79 days in our cohort. PMID:22591965

Top