Science.gov

Sample records for high precision chromium

  1. Chromium at High Pressure

    NASA Astrophysics Data System (ADS)

    Jaramillo, Rafael

    2012-02-01

    Chromium has long served as the archetype of spin density wave magnetism. Recently, Jaramillo and collaborators have shown that Cr also serves as an archetype of magnetic quantum criticality. Using a combination of x-ray diffraction and electrical transport measurements at high pressures and cryogenic temperatures in a diamond anvil cell, they have demonstrated that the N'eel transition (TN) can be continuously suppressed to zero, with no sign of a concurrent structural transition. The order parameter undergoes a broad regime of exponential suppression, consistent with the weak coupling paradigm, before deviating from a BCS-like ground state within a narrow but accessible quantum critical regime. The quantum criticality is characterized by mean field scaling of TN and non mean field scaling of the transport coefficients, which points to a fluctuation-induced reconstruction of the critical Fermi surface. A comparison between pressure and chemical doping as means to suppress TN sheds light on different routes to the quantum critical point and the relevance of Fermi surface nesting and disorder at this quantum phase transition. The work by Jaramillo et al. is broadly relevant to the study of magnetic quantum criticality in a physically pure and theoretically tractable system that balances elements of weak and strong coupling. [4pt] [1] R. Jaramillo, Y. Feng, J. Wang & T. F. Rosenbaum. Signatures of quantum criticality in pure Cr at high pressure. Proc. Natl. Acad. Sci. USA 107, 13631 (2010). [0pt] [2] R. Jaramillo, Y. Feng, J. C. Lang, Z. Islam, G. Srajer, P. B. Littlewood, D. B. McWhan & T. F. Rosenbaum. Breakdown of the Bardeen-Cooper-Schrieffer ground state at a quantum phase transition. Nature 459, 405 (2009).

  2. Chromium.

    PubMed

    Barceloux, D G

    1999-01-01

    Chromium occurs primarily in the trivalent state (III), which is the most stable form, or in the hexavalent state (VI), which is a strong oxidizing agent. Elemental chromium (0) does not occur naturally on earth. Trivalent chromium (III) is an essential trace metal necessary for the formation of glucose tolerance factor and for the metabolism of insulin. Commercial applications of chromium compounds include tanning (III), corrosion inhibition, plating, glassware-cleaning solutions, wood preservatives (VI), manufacture of safety matches, metal finishing (VI), and the production of pigments (III, VI). Hexavalent chromium (VI) contaminated local soil when chromium waste slag was part of the fill material present in residential, public, and industrial areas. In some urban areas, about two-thirds of the chromium in air results from the emission of hexavalent chromium from fossil fuel combustion and steel production. The remaining chromium in air is the trivalent form. The residence time of chromium in air is < 10 days, depending on the particle size. Trivalent compounds generally have low toxicity and the gastrointestinal tract poorly absorbs these compounds. Hexavalent chromium is a skin and mucous membrane irritant and some of these hexavalent compounds are strong corrosive agents. Hexavalent chromium compounds also produce an allergic contact dermatitis characterized by eczema. Sensitivity to trivalent compounds is much less frequent, but some workers may react to high concentrations of these compounds. Hexavalent chromium is recognized by the International Agency for Research on Cancer and by the US Toxicology Program as a pulmonary carcinogen. The increased risk of lung cancer occurs primarily in workers exposed to hexavalent chromium dust during the refining of chromite ore and the production of chromate pigments. Although individual studies suggest the possibility of an excess incidence of cancer at sites outside the lung, the results from these studies are

  3. Welding of high chromium steels

    NASA Technical Reports Server (NTRS)

    Miller, W B

    1928-01-01

    A brief description is given of different groups of high chromium steels (rustless iron and stainless steels) according to their composition and more generally accepted names. The welding procedure for a given group will be much the same regardless of the slight variations in chemical composition which may exist within a certain group. Information is given for the tensile properties (yield point and ultimate strength) of metal sheets and welds before and after annealing on coupons one and one-half inches wide. Since welds in rustless iron containing 16 to 18 percent chromium and 7 to 12 percent nickel show the best combination of strength and ductility in the 'as welded' or annealed condition, it is considered the best alloy to use for welded construction.

  4. High Precision GPS Measurements

    DTIC Science & Technology

    2010-02-28

    GNSS Service (IGS) database, and magnetic field vectors from the International Geomagnetic Reference Field (IGRF) model [9]. These combined...Additonal correlations between the higher order range error and geomagnetic activity and seasonal variations are also obtained. Fig. 4 shows...clear correlation between the geomagnetic activity and enhanced higher order error at both sites. High Precision GPS Final Report Page 5 Fig.3

  5. Protective claddings for high strength chromium alloys

    NASA Technical Reports Server (NTRS)

    Collins, J. F.

    1971-01-01

    The application of a Cr-Y-Hf-Th alloy as a protective cladding for a high strength chromium alloy was investigated for its effectiveness in inhibiting nitrogen embrittlement of a core alloy. Cladding was accomplished by a combination of hot gas pressure bonding and roll cladding techniques. Based on bend DBTT, the cladding alloy was effective in inhibiting nitrogen embrittlement of the chromium core alloy for up to 720 ks (200hours) in air at 1422 K (2100 F). A significant increase in the bend DBTT occurred with longer time exposures at 1422 K or short time exposures at 1589 K (2400 F).

  6. Precise measurement of chromium isotopes by MC-ICPMS.

    PubMed

    Schiller, Martin; Van Kooten, Elishevah; Holst, Jesper C; Olsen, Mia B; Bizzarro, Martin

    2014-08-01

    We report novel analytical procedures allowing for the concurrent determination of the stable and mass-independent Cr isotopic composition of silicate materials by multiple collector inductively coupled mass spectrometry (MC-ICPMS). In particular, we focus on improved precision of the measurement of the neutron-rich isotope (54)Cr. Because nitride and oxide interferences are a major obstacle to precise and accurate (54)Cr measurements by MC-ICPMS, our approach is designed to minimize these interferences. Based on repeat measurements of standards, we show that the mass-independent (53)Cr and (54)Cr compositions can be routinely determined with an external reproducibility better than 2.5 and 5.8 ppm (2 sd), respectively. This represents at least a two-fold improvement compared to previous studies. Although this approach uses significantly more Cr (30-60 μg) than analysis by thermal ionization mass spectrometry (TIMS), our result indicate that it is possible to obtain an external reproducibility of 19 ppm for the μ(54)Cr when consuming amounts similar to that typically analyzed by TIMS (1 μg). In addition, the amount of time required for analysis by MC-ICPMS is much shorter thereby enabling a higher sample throughput. As a result of the improved analytical precision, we identified small apparent mass-independent differences between different synthetic Cr standards and bulk silicate Earth (BSE) when using the kinetic law for the mass bias correction. These differences are attributed to the Cr loss by equilibrium processes during production of the synthetic standards. The stable isotope data concurrently obtained have a precision of 0.05‰ Da (-1), which is comparable to earlier studies. Comparison of the measured isotopic composition of four meteorites with published data indicates that Cr isotope data measured by the technique described here are accurate to stated uncertainties. The stable Cr composition of the Bilanga and NWA 2999 achondrites suggests that the

  7. Precise measurement of chromium isotopes by MC-ICPMS

    PubMed Central

    Schiller, Martin; Van Kooten, Elishevah; Holst, Jesper C.; Olsen, Mia B.; Bizzarro, Martin

    2014-01-01

    We report novel analytical procedures allowing for the concurrent determination of the stable and mass-independent Cr isotopic composition of silicate materials by multiple collector inductively coupled mass spectrometry (MC-ICPMS). In particular, we focus on improved precision of the measurement of the neutron-rich isotope 54Cr. Because nitride and oxide interferences are a major obstacle to precise and accurate 54Cr measurements by MC-ICPMS, our approach is designed to minimize these interferences. Based on repeat measurements of standards, we show that the mass-independent 53Cr and 54Cr compositions can be routinely determined with an external reproducibility better than 2.5 and 5.8 ppm (2 sd), respectively. This represents at least a two-fold improvement compared to previous studies. Although this approach uses significantly more Cr (30–60 μg) than analysis by thermal ionization mass spectrometry (TIMS), our result indicate that it is possible to obtain an external reproducibility of 19 ppm for the μ54Cr when consuming amounts similar to that typically analyzed by TIMS (1 μg). In addition, the amount of time required for analysis by MC-ICPMS is much shorter thereby enabling a higher sample throughput. As a result of the improved analytical precision, we identified small apparent mass-independent differences between different synthetic Cr standards and bulk silicate Earth (BSE) when using the kinetic law for the mass bias correction. These differences are attributed to the Cr loss by equilibrium processes during production of the synthetic standards. The stable isotope data concurrently obtained have a precision of 0.05‰ Da −1, which is comparable to earlier studies. Comparison of the measured isotopic composition of four meteorites with published data indicates that Cr isotope data measured by the technique described here are accurate to stated uncertainties. The stable Cr composition of the Bilanga and NWA 2999 achondrites suggests that the

  8. Chromium

    USDA-ARS?s Scientific Manuscript database

    The effects of chromium (Cr) on glucose and insulin metabolism are well documented. Normal dietary intake of Cr appears to be suboptimal because several studies have reported beneficial effects of Cr in people with elevated blood glucose or type 2 diabetes eating conventional diets. Stresses that ...

  9. Boriding of high carbon high chromium cold work tool steel

    NASA Astrophysics Data System (ADS)

    Muhammad, W.

    2014-06-01

    High-carbon high-chromium cold work tool steels are widely used for blanking and cold forming of punches and dies. It is always advantageous to obtain an increased wear resistant surface to improve life and performance of these steels. In this connection boriding of a high-carbon high-chromium cold work die steel, D3, was conducted in a mixture of 30% B4C, 70% borax at 950 °C for two, four and six hours. Case depth of the borided layer obtained was between 40 to 80 μm. After boriding, the surface hardness achieved was between 1430 to 1544 HV depending upon the process time. X-ray diffraction studies confirmed the formation of a duplex compound layer consisting of FeB and Fe2B. It is generally considered that FeB is undesirable because of its inherent brittleness. Post boriding treatment (homogenization) transformed the compound layer into single-phase layer of Fe2B, while surface hardness decreased to 1345-1430 HV. Pin-on-disc wer test showed that wear resistance of the borided samples was superior as compared to non-borided material and increased with boriding time.

  10. The nature of temper brittleness of high-chromium ferrite

    SciTech Connect

    Sarrak, V.I.; Suvorova, S.O.; Golovin, I.S.; Mishin, V.M.; Kislyuk, I.V.

    1995-03-01

    The reasons for development of {open_quotes}475{degrees}C brittleness{close_quotes} of high-chromium ferritic steels are considered from the standpoint of fracture mechanics. It is shown that the general rise in the curve of temperature-dependent local flow stress has the decisive influence on the position of the ductile-to-brittle transformation temperature and the increase in it as the result of a hold at temperatures of development of brittleness. The established effect is related to the change in the parameters determining dislocation mobility, that is, the activation energy of dislocation movement in high-chromium ferrite and the resistance to microplastic deformation, both caused by processes of separation into layers of high-chromium ferrite and decomposition of the interstitial solid solution.

  11. High precision redundant robotic manipulator

    DOEpatents

    Young, Kar-Keung David

    1998-01-01

    A high precision redundant robotic manipulator for overcoming contents imposed by obstacles or imposed by a highly congested work space. One embodiment of the manipulator has four degrees of freedom and another embodiment has seven degreed of freedom. Each of the embodiments utilize a first selective compliant assembly robot arm (SCARA) configuration to provide high stiffness in the vertical plane, a second SCARA configuration to provide high stiffness in the horizontal plane. The seven degree of freedom embodiment also utilizes kinematic redundancy to provide the capability of avoiding obstacles that lie between the base of the manipulator and the end effector or link of the manipulator. These additional three degrees of freedom are added at the wrist link of the manipulator to provide pitch, yaw and roll. The seven degrees of freedom embodiment uses one revolute point per degree of freedom. For each of the revolute joints, a harmonic gear coupled to an electric motor is introduced, and together with properly designed based servo controllers provide an end point repeatability of less than 10 microns.

  12. High precision redundant robotic manipulator

    DOEpatents

    Young, K.K.D.

    1998-09-22

    A high precision redundant robotic manipulator for overcoming contents imposed by obstacles or imposed by a highly congested work space is disclosed. One embodiment of the manipulator has four degrees of freedom and another embodiment has seven degrees of freedom. Each of the embodiments utilize a first selective compliant assembly robot arm (SCARA) configuration to provide high stiffness in the vertical plane, a second SCARA configuration to provide high stiffness in the horizontal plane. The seven degree of freedom embodiment also utilizes kinematic redundancy to provide the capability of avoiding obstacles that lie between the base of the manipulator and the end effector or link of the manipulator. These additional three degrees of freedom are added at the wrist link of the manipulator to provide pitch, yaw and roll. The seven degrees of freedom embodiment uses one revolute point per degree of freedom. For each of the revolute joints, a harmonic gear coupled to an electric motor is introduced, and together with properly designed based servo controllers provide an end point repeatability of less than 10 microns. 3 figs.

  13. The high temperature impact response of tungsten and chromium

    NASA Astrophysics Data System (ADS)

    Zaretsky, E. B.; Kanel, G. I.

    2017-09-01

    The evolution of elastic-plastic shock waves has been studied in pure polycrystalline tungsten and chromium at room and elevated temperatures over propagation distances ranging from 0.05 to 3 mm (tungsten) and from 0.1 to 2 mm (chromium). The use of fused silica windows in all but one experiment with chromium and in several high temperature experiments with tungsten led to the need for performing shock and optic characterization of these windows over the 300-1200 K temperature interval. Experiments with tungsten and chromium samples showed that annealing of the metals transforms the initial ramping elastic wave into a jump-like wave, substantially increasing the Hugoniot elastic limits of the metals. With increased annealing time, the spall strength of the two metals slightly increases. Both at room and at high temperatures, the elastic precursor in the two metals decays in two distinct regimes. At propagation distances smaller than ˜1 mm (tungsten) or ˜0.5 mm (chromium), decay is fast, with the dislocation motion and multiplication being controlled by phonon viscous drag. At greater distances, the rate of decay becomes much lower, with control of the plastic deformation being passed to the thermally activated generation and motion of dislocation double-kinks. The stress at which this transition takes place virtually coincides with the Peierls stress τP of the active glide system. Analysis of the annealing effects in both presently and previously studied BCC metals (i.e., Ta, V, Nb, Mo, W, and Cr) and of the dependencies of their normalized Peierls stresses τP(θ) /τP(0 ) on the normalized temperature θ=T /Tm allows one to conclude that the non-planar, split into several glide planes, structure of the dislocation core in these metals is mainly responsible for their plastic deformation features.

  14. Development of ductile high-strength chromium alloys, phase 2

    NASA Technical Reports Server (NTRS)

    Filippi, A. M.

    1973-01-01

    Strength and ductility were evaluated for chromium alloys dispersion hardened with the putative TaC, TaB, CbC, and CbB compounds. TaC and TaB proved to be the most potent strengtheners, but when combined, their effect far outweighed that produced individually. Tests at 1422 K (2100 F) on an alloy containing these two compounds at the combined level of 0.5 m/o revealed a 495 MN/sq m (70 ksi) tensile strength for wrought material, and a 100 hour rupture strength of 208 MN/sq m (30 ksi) when solution annealed and aged to maximize creep resistance. These levels of high temperature strength greatly exceed that reported for any other chromium-base alloy. The ductile-to-brittle transition temperature (DBTT) of the two phase strengthened alloy occurred at approximately 588 K (600 F) when heat treated to optimize creep strength and was not improved by fabrication to produce a wrought and recovered microstructure. The lowest DBTT measured on any of the alloys investigated was 422 K (300 F). Strengthening phases actually formed in Cr-Ta-B and Cr-Cb-B compositions are probable M2CrB2 (M=Ta or Cb) compounds of tetragonal crystal structure. The likely habit relationship between these compounds and chromium is postulated. Cube habit coherency was identified for TaC precipitation in chromium by electron microscopy. In another study, the maximum solubility of carbon in chromium was indicated to lie between 3/4 and 1 a/o and that of boron to be 1/2 a/o.

  15. Reactor target from metal chromium for "pure" high-intensive artificial neutrino source

    NASA Astrophysics Data System (ADS)

    Gavrin, V. N.; Kozlova, Yu. P.; Veretenkin, E. P.; Logachev, A. V.; Logacheva, A. I.; Lednev, I. S.; Okunkova, A. A.

    2017-01-01

    The paper presents the first results of development of manufacturing technology of metallic chromium targets from highly enriched isotope 50Cr for irradiation in a high flux nuclear reactor to obtain a compact high intensity neutrino source with low content of radionuclide impurities and minimum losses of enriched isotope. The main technological stages are the hydrolysis of chromyl fluoride, the electrochemical reduction of metallic chromium, the hot isostatic pressing of chromium powder and the electrical discharge machining of chromium bars. The technological stages of hot isostatic pressing of chromium powder and of electrical discharge machining of Cr rods have been tested.

  16. High precision anatomy for MEG.

    PubMed

    Troebinger, Luzia; López, José David; Lutti, Antoine; Bradbury, David; Bestmann, Sven; Barnes, Gareth

    2014-02-01

    Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1mm. Estimates of relative co-registration error were <1.5mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG. © 2013. Published by Elsevier Inc. All rights reserved.

  17. Highly Parallel, High-Precision Numerical Integration

    SciTech Connect

    Bailey, David H.; Borwein, Jonathan M.

    2005-04-22

    This paper describes a scheme for rapidly computing numerical values of definite integrals to very high accuracy, ranging from ordinary machine precision to hundreds or thousands of digits, even for functions with singularities or infinite derivatives at endpoints. Such a scheme is of interest not only in computational physics and computational chemistry, but also in experimental mathematics, where high-precision numerical values of definite integrals can be used to numerically discover new identities. This paper discusses techniques for a parallel implementation of this scheme, then presents performance results for 1-D and 2-D test suites. Results are also given for a certain problem from mathematical physics, which features a difficult singularity, confirming a conjecture to 20,000 digit accuracy. The performance rate for this latter calculation on 1024 CPUs is 690 Gflop/s. We believe that this and one other 20,000-digit integral evaluation that we report are the highest-precision non-trivial numerical integrations performed to date.

  18. Ferrate treatment for removing chromium from high-level radioactive tank waste.

    PubMed

    Sylvester, P; Rutherford, L A; Gonzalez-Martin, A; Kim, J; Rapko, B M; Lumetta, G J

    2001-01-01

    A method has been developed for removing chromium from alkaline high-level radioactive tank waste. Removing chromium from these wastes is critical in reducing the volume of waste requiring expensive immobilization and deep geologic disposition. The method developed is based on the oxidation of insoluble chromium(III) compounds to soluble chromate using ferrate. This method could be generally applicable to removing chromium from chromium-contaminated solids, when coupled with a subsequent reduction of the separated chromate back to chromium(III). The tests conducted with a simulated Hanford tank sludge indicate that the chromium removal with ferrate is more efficient at 5 M NaOH than at 3 M NaOH. Chromium removal increases with increasing Fe(VI)/Cr(II) molar ratio, but the chromium removal tends to level out for Fe(VI)/ Cr(III) greaterthan 10. Increasingtemperature leadsto better chromium removal, but higher temperatures also led to more rapid ferrate decomposition. Tests with radioactive Hanford tank waste generally confirmed the simulant results. In all cases examined, ferrate enhanced the chromium removal, with a typical removal of around 60-70% of the total chromium present in the washed sludge solids. The ferrate leachate solutions did not contain significant concentrations of transuranic elements, so these solutions could be disposed as low-activity waste.

  19. High precision triangular waveform generator

    DOEpatents

    Mueller, Theodore R.

    1983-01-01

    An ultra-linear ramp generator having separately programmable ascending and descending ramp rates and voltages is provided. Two constant current sources provide the ramp through an integrator. Switching of the current at current source inputs rather than at the integrator input eliminates switching transients and contributes to the waveform precision. The triangular waveforms produced by the waveform generator are characterized by accurate reproduction and low drift over periods of several hours. The ascending and descending slopes are independently selectable.

  20. High precision modeling for fundamental physics experiments

    NASA Astrophysics Data System (ADS)

    Rievers, Benny; Nesemann, Leo; Costea, Adrian; Andres, Michael; Stephan, Ernst P.; Laemmerzahl, Claus

    With growing experimental accuracies and high precision requirements for fundamental physics space missions the needs for accurate numerical modeling techniques are increasing. Motivated by the challenge of length stability in cavities and optical resonators we propose the develop-ment of a high precision modeling tool for the simulation of thermomechanical effects up to a numerical precision of 10-20 . Exemplary calculations for simplified test cases demonstrate the general feasibility of high precision calculations and point out the high complexity of the task. A tool for high precision analysis of complex geometries will have to use new data types, advanced FE solver routines and implement new methods for the evaluation of numerical precision.

  1. Effect of Chromium on Microstructure and Properties of High Boron White Cast Iron

    NASA Astrophysics Data System (ADS)

    Liu, Zhongli; Chen, Xiang; Li, Yanxiang; Hu, Kaihua

    2008-03-01

    In this article, the effect of chromium on microstructure and properties of high boron white cast iron was studied. The results indicate that the microstructure of high boron white cast iron with different chromium content comprises a dendritic matrix and interdendritic eutectics, and the eutectic compound has a M2B-type chemical formula that does not change with the difference of chromium content. The increase of chromium not only increases the microhardness of boride, but also improves the morphology of boride, which is changed from continuous network to less continuous distribution. Moreover, with the chromium increase, martensite appears in the matrix under the as-cast condition, the appearance of which depends on the increase of chromium in the matrix and the uneven distribution of carbon in the matrix caused by chromium addition. After quenching in air, the matrixes of alloys all change to martensite. However, some secondary particles are found in the central area of the dendrite grains of alloys with higher chromium, and their existence is due to the difference of boron solubility in the matrix with different chromium content. In addition, the hardenability, hardness, and impact toughness are all improved with the increase in chromium.

  2. High Precision Laser Range Sensor

    NASA Technical Reports Server (NTRS)

    Dubovitsky, Serge (Inventor); Lay, Oliver P. (Inventor)

    2003-01-01

    The present invention is an improved distance measuring interferometer that includes high speed phase modulators and additional phase meters to generate and analyze multiple heterodyne signal pairs with distinct frequencies. Modulation sidebands with large frequency separation are generated by the high speed electro-optic phase modulators, requiring only a single frequency stable laser source and eliminating the need for a fist laser to be tuned or stabilized relative to a second laser. The combination of signals produced by the modulated sidebands is separated and processed to give the target distance. The resulting metrology apparatus enables a sensor with submicron accuracy or better over a multi- kilometer ambiguity range.

  3. High precision thermal neutron detectors

    SciTech Connect

    Radeka, V.; Schaknowski, N.A.; Smith, G.C.; Yu, B.

    1994-12-31

    Two-dimensional position sensitive detectors are indispensable in neutron diffraction experiments for determination of molecular and crystal structures in biology, solid-state physics and polymer chemistry. Some performance characteristics of these detectors are elementary and obvious, such as the position resolution, number of resolution elements, neutron detection efficiency, counting rate and sensitivity to gamma-ray background. High performance detectors are distinguished by more subtle characteristics such as the stability of the response (efficiency) versus position, stability of the recorded neutron positions, dynamic range, blooming or halo effects. While relatively few of them are needed around the world, these high performance devices are sophisticated and fairly complex, their development requires very specialized efforts. In this context, we describe here a program of detector development, based on {sup 3}He filled proportional chambers, which has been underway for some years at the Brookhaven National Laboratory. Fundamental approaches and practical considerations are outlined that have resulted in a series of high performance detectors with the best known position resolution, position stability, uniformity of response and reliability over time, for devices of this type.

  4. High strength nickel-chromium-iron austenitic alloy

    DOEpatents

    Gibson, Robert C.; Korenko, Michael K.

    1980-01-01

    A solid solution strengthened Ni-Cr-Fe alloy capable of retaining its strength at high temperatures and consisting essentially of 42 to 48% nickel, 11 to 13% chromium, 2.6 to 3.4% niobium, 0.2 to 1.2% silicon, 0.5 to 1.5% vanadium, 2.6 to 3.4% molybdenum, 0.1 to 0.3% aluminum, 0.1 to 0.3% titanium, 0.02 to 0.05% carbon, 0.002 to 0.015% boron, up to 0.06 zirconium, and the balance iron. After solution annealing at 1038.degree. C. for one hour, the alloy, when heated to a temperature of 650.degree. C., has a 2% yield strength of 307 MPa, an ultimate tensile strength of 513 MPa and a rupture strength of as high as 400 MPa after 100 hours.

  5. Solidification structure and abrasion resistance of high chromium white irons

    NASA Astrophysics Data System (ADS)

    Doğan, Ö. N.; Hawk, J. A.; Laird, G.

    1997-06-01

    Superior abrasive wear resistance, combined with relatively low production costs, makes high Cr white cast irons (WCIs) particularly attractive for applications in the grinding, milling, and pumping apparatus used to process hard materials. Hypoeutectic, eutectic, and hypereutectic cast iron compositions, containing either 15 or 26 wt pct chromium, were studied with respect to the macrostructural transitions of the castings, solidification paths, and resulting microstructures when poured with varying superheats. Completely equiaxed macrostructures were produced in thick section castings with slightly hypereutectic compositions. High-stress abrasive wear tests were then performed on the various alloys to examine the influence of both macrostructure and microstructure on wear resistance. Results indicated that the alloys with a primarily austenitic matrix had a higher abrasion resistance than similar alloys with a pearlitic/bainitic matrix. Improvement in abrasion resistance was partially attributed to the ability of the austenite to transform to martensite at the wear surface during the abrasion process.

  6. High precision neutron inelastic cross section measurements

    NASA Astrophysics Data System (ADS)

    Olacel, A.; Belloni, F.; Borcea, C.; Boromiza, M.; Dessagne, Ph.; Henning, G.; Kerveno, M.; Negret, A.; Nyman, M.; Pirovano, E.; Plompen, A.

    2017-06-01

    High precision neutron inelastic scattering cross section data are very important for the development of the new generation of nuclear reactors (Gen IV). Our experiments, performed using the GELINA neutron source and the GAINS spectrometer of the European Commission Joint Research Center, Geel, produce highly reliable and precise cross section data. We will present the details of the setup and the data analysis technique allowing production of such unique results, and we will show examples of two experimental results.

  7. Precision Crystal Calorimeters in High Energy Physics

    ScienceCinema

    Ren-Yuan Zhu

    2016-07-12

    Precision crystal calorimeters traditionally play an important role in high energy physics experiments. In the last two decades, it faces a challenge to maintain its precision in a hostile radiation environment. This paper reviews the performance of crystal calorimeters constructed for high energy physics experiments and the progress achieved in understanding crystal’s radiation damage as well as in developing high quality scintillating crystals for particle physics. Potential applications of new generation scintillating crystals of high density and high light yield, such as LSO and LYSO, in particle physics experiments is also discussed.

  8. High-precision arithmetic in mathematical physics

    DOE PAGES

    Bailey, David H.; Borwein, Jonathan M.

    2015-05-12

    For many scientific calculations, particularly those involving empirical data, IEEE 32-bit floating-point arithmetic produces results of sufficient accuracy, while for other applications IEEE 64-bit floating-point is more appropriate. But for some very demanding applications, even higher levels of precision are often required. Furthermore, this article discusses the challenge of high-precision computation, in the context of mathematical physics, and highlights what facilities are required to support future computation, in light of emerging developments in computer architecture.

  9. High-valent imido complexes of manganese and chromium corroles.

    PubMed

    Edwards, Nicola Y; Eikey, Rebecca A; Loring, Megan I; Abu-Omar, Mahdi M

    2005-05-16

    The oxidation reaction of M(tpfc) [M = Mn or Cr and tpfc = tris(pentafluorophenyl)corrole] with aryl azides under photolytic or thermal conditions gives the first examples of mononuclear imido complexes of manganese(V) and chromium(V). These complexes have been characterized by NMR, mass spectrometry, UV-vis, EPR, elemental analysis, and cyclic voltammetry. Two X-ray structures have been obtained for Mn(tpfc)(NMes) and Cr(tpfc)(NMes) [Mes = 2,4,6-(CH(3))(3)C(6)H(2)]. Short metal-imido bonds (1.610 and 1.635 Angstroms) as well as nearly linear M-N-C angles are consistent with triple M triple-bond NR bond formation. The kinetics of nitrene [NR] group transfer from manganese(V) corroles to various organic phosphines have been defined. Reduction of the manganese(V) corrolato complex affords phosphine imine and Mn(III) with reaction rates that are sensitive to steric and electronic elements of the phosphine substrate. An analogous manganese complex with a variant corrole ligand containing bromine atoms in the beta-pyrrole positions, Mn(Br(8)tpfc)(NAr), has been prepared and studied. Its reaction with PEt(3) is 250x faster than that of the parent tpfc complex, and its Mn(V/IV) couple is shifted by 370 mV to a more positive potential. The EPR spectra of chromium(V) imido corroles reveal a rich signal at ambient temperature consistent with Cr(V) triple-bond NR (d(1), S = 1/2) containing a localized spin density in the d(xy) orbital, and an anisotropic signal at liquid nitrogen temperature. Our results demonstrate the synthetic utility of organic aryl azides in the preparation of mononuclear metal imido complexes previously considered elusive, and suggest strong sigma-donation as the underlying factor in stabilizing high-valent metals by corrole ligands.

  10. Carbides in a High-Chromium Ferritic/Martensitic Steel

    NASA Astrophysics Data System (ADS)

    Shen, Yin Zhong; Ji, Bo; Zhou, Xiao Ling; Zhu, Jun

    2014-06-01

    The precipitate phases in an 11 pct Cr ferritic/martensitic steel normalized at 1323 K (1050 °C) for 0.5 hour and tempered at 1053 K (780 °C) for 1.5 hours have been investigated. Except for dominant phases, Cr-rich M23C6 carbide and Nb-rich, Ta-Nb-rich, and V-rich MC carbides, needle-like precipitates with a typical size of 70 to 310 and 10 to 30 nm for the length of the long and short axis of the needles, respectively, were also observed on the extraction carbon replica of the steel. The typical metallic element composition of the needle-like precipitates is about 53-82Fe, 14-26Cr, 0.5-18Ta, 1-6W, and 2-5Co in atomic pct. Through energy dispersive X-ray analysis and electron diffraction along with calculations regarding lattice parameter and interplanar spacing, the needle-like precipitates were identified as a Fe-rich M5C2 carbide, which is not known to have been reported previously in high-chromium steels. The M5C2 carbide has a base-centered monoclinic crystal structure with the approximate lattice parameters a/ b/ c = 1.142/0.5186/0.5383 nm and β = 104.68 deg. The formation of the Fe-rich M5C2 carbides in the steel has been discussed. The effect of chromium content in matrix and boron addition on the precipitate phases in ferritic/martensitic steels has also been discussed.

  11. High precision phase-shifting electron holography

    PubMed

    Yamamoto; Kawajiri; Tanji; Hibino; Hirayama

    2000-01-01

    Today's information-oriented society requires high density and high quality magnetic recording media. The quantitative observation of fine magnetic structures by electron holography is greatly anticipated in the development of such new recording materials. However, the magnetic fields around particles <50 nm have not been observed, because the fields are too weak to observe in the usual way. Here we present a highly precise phase measurement technique: improved phase-shifting electron holography. Using this method, the electric field around a charged polystyrene latex particle (100 nm in diameter) and the magnetic field around iron particles (30 nm in diameter) are observed precisely. A precision of the reconstructed phase image of 2pi/300 rad is achieved in the image of the latex particle.

  12. High-Precision Computation and Mathematical Physics

    SciTech Connect

    Bailey, David H.; Borwein, Jonathan M.

    2008-11-03

    At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion effort. This paper presents a survey of recent applications of these techniques and provides some analysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, scattering amplitudes of quarks, gluons and bosons, nonlinear oscillator theory, Ising theory, quantum field theory and experimental mathematics. We conclude that high-precision arithmetic facilities are now an indispensable component of a modern large-scale scientific computing environment.

  13. High-precision laser machining of ceramics

    NASA Astrophysics Data System (ADS)

    Toenshoff, Hans K.; von Alvensleben, Ferdinand; Graumann, Christoph; Willmann, Guido

    1998-09-01

    The increasing demand for highly developed ceramic materials for various applications calls for innovative machining technologies yielding high accuracy and efficiency. Associated problems with conventional, i.e. mechanical methods, are unacceptable tool wear as well as force induced damages on ceramic components. Furthermore, the established grinding techniques often meet their limits if accurate complex 2D or 3D structures are required. In contrast to insufficient mechanical processes, UV-laser precision machining of ceramics offers not only a valuable technological alternative but a considerable economical aspect as well. In particular, excimer lasers provide a multitude of advantages for applications in high precision and micro technology. Within the UV wavelength range and pulses emitted in the nano-second region, minimal thermal effects on ceramics and polymers are observed. Thus, the ablation geometry can be controlled precisely in the lateral and vertical directions. In this paper, the excimer laser machining technology developed at the Laser Zentrum Hannover is explained. Representing current and future industrial applications, examinations concerning the precision cutting of alumina (Al2O3), and HF-composite materials, the ablation of ferrite ceramics for precision inductors and the structuring of SiC sealing and bearing rings are presented.

  14. High precision, rapid laser hole drilling

    DOEpatents

    Chang, Jim J.; Friedman, Herbert W.; Comaskey, Brian J.

    2013-04-02

    A laser system produces a first laser beam for rapidly removing the bulk of material in an area to form a ragged hole. The laser system produces a second laser beam for accurately cleaning up the ragged hole so that the final hole has dimensions of high precision.

  15. High-Precision Photometry with the RCT

    NASA Astrophysics Data System (ADS)

    Everett, M.; Howell, S.; Davis, D.; McGruder, C. H., III; Gelderman, R.; Guinan, E.; Mattox, J. R.; Walter, D. K.

    2003-05-01

    We plan to conduct a high-precision photometric search for transitting extra-solar planets using the refurbished 1.3 m (50 inch) Robotically-Controlled Telescope (RCT) at Kitt Peak. The photometric capabilities and extra-solar planet search strategy for the RCT are discussed. Refurbishment of the RCT has been made possible by NASA grant NAG58762.

  16. High Precision Pressure Measurement with a Funnel

    ERIC Educational Resources Information Center

    Lopez-Arias, T.; Gratton, L. M.; Oss, S.

    2008-01-01

    A simple experimental device for high precision differential pressure measurements is presented. Its working mechanism recalls that of a hydraulic press, where pressure is supplied by insufflating air under a funnel. As an application, we measure air pressure inside a soap bubble. The soap bubble is inflated and connected to a funnel which is…

  17. High precision measurements in crustal dynamic studies

    NASA Technical Reports Server (NTRS)

    Wyatt, F.; Berger, J.

    1984-01-01

    The development of high-precision instrumentation for monitoring benchmark stability and evaluating coseismic strain and tilt signals is reviewed. Laser strainmeter and tilt observations are presented. Examples of coseismic deformation in several geographic locations are given. Evidence suggests that the Earth undergoes elastic response to abrupt faulting.

  18. High Precision Pressure Measurement with a Funnel

    ERIC Educational Resources Information Center

    Lopez-Arias, T.; Gratton, L. M.; Oss, S.

    2008-01-01

    A simple experimental device for high precision differential pressure measurements is presented. Its working mechanism recalls that of a hydraulic press, where pressure is supplied by insufflating air under a funnel. As an application, we measure air pressure inside a soap bubble. The soap bubble is inflated and connected to a funnel which is…

  19. High precision, rapid laser hole drilling

    DOEpatents

    Chang, Jim J.; Friedman, Herbert W.; Comaskey, Brian J.

    2005-03-08

    A laser system produces a first laser beam for rapidly removing the bulk of material in an area to form a ragged hole. The laser system produces a second laser beam for accurately cleaning up the ragged hole so that the final hole has dimensions of high precision.

  20. High precision, rapid laser hole drilling

    DOEpatents

    Chang, Jim J.; Friedman, Herbert W.; Comaskey, Brian J.

    2007-03-20

    A laser system produces a first laser beam for rapidly removing the bulk of material in an area to form a ragged hole. The laser system produces a second laser beam for accurately cleaning up the ragged hole so that the final hole has dimensions of high precision.

  1. High precision detector robot arm system

    DOEpatents

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  2. High precision Woelter optic calibration facility

    SciTech Connect

    Morales, R.I.; Remington, B.A.; Schwinn, T. )

    1995-01-01

    We have developed an off-line facility for very precise characterization of the reflectance and spatial resolution of the grazing incidence Woelter type I x-ray optics used at Nova. The primary component of the facility is a new, very versatile, high brightness x-ray source consisting of a focused DC electron beam incident onto a precision manipulated target-pinhole array. The data are recorded with a selection of detectors. For imaging measurements we use direct exposure x-ray film modules or an x-ray charge-coupled device camera. For energy-resolved reflectance measurements, we use lithium drifted silicon detectors and a proportional counter. An [ital in] [ital situ] laser alignment system allows precise location and rapid periodic alignment verification of the x-ray point source, the statically mounted Woelter optic, and the chosen detector.

  3. High precision Woelter optic calibration facility

    SciTech Connect

    Morales, R.I.; Remington, B.A.; Schwinn, T.

    1994-05-02

    We have developed an off-line facility for very precise characterization of the reflectance and spatial resolution of the grazing incidence Woelter Type 1 x-ray optics used at Nova. The primary component of the facility is a high brightness, ``point`` x-ray source consisting of a focussed DC electron beam incident onto a precision manipulated target/pinhole array. The data are recorded with a selection of detectors. For imaging measurements we use direct exposure x-ray film modules or an x-ray CCD camera. For energy-resolved reflectance measurements, we use lithium drifted silicon detectors and a proportional counter. An in situ laser alignment system allows precise location and rapid periodic alignment verification of the x-ray point source, the statically mounted Woelter optic, and the chosen detector.

  4. Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis.

    PubMed

    Silva, Arlene S; Brandao, Geovani C; Matos, Geraldo D; Ferreira, Sergio L C

    2015-11-01

    The present work proposed an analytical method for the direct determination of chromium in infant formulas employing the high-resolution continuum source electrothermal atomic absorption spectrometry combined with the solid sample analysis (SS-HR-CS ET AAS). Sample masses up to 2.0mg were directly weighted on a solid sampling platform and introduced into the graphite tube. In order to minimize the formation of carbonaceous residues and to improve the contact of the modifier solution with the solid sample, a volume of 10 µL of a solution containing 6% (v/v) H2O2, 20% (v/v) ethanol and 1% (v/v) HNO3 was added. The pyrolysis and atomization temperatures established were 1600 and 2400 °C, respectively, using magnesium as chemical modifier. The calibration technique was evaluated by comparing the slopes of calibration curves established using aqueous and solid standards. This test revealed that chromium can be determined employing the external calibration technique using aqueous standards. Under these conditions, the method developed allows the direct determination of chromium with limit of quantification of 11.5 ng g(-1), precision expressed as relative standard deviation (RSD) in the range of 4.0-17.9% (n=3) and a characteristic mass of 1.2 pg of chromium. The accuracy was confirmed by analysis of a certified reference material of tomato leaves furnished by National Institute of Standards and Technology. The method proposed was applied for the determination of chromium in five different infant formula samples. The chromium content found varied in the range of 33.9-58.1 ng g(-1) (n=3). These samples were also analyzed employing ICP-MS. A statistical test demonstrated that there is no significant difference between the results found by two methods. The chromium concentrations achieved are lower than the maximum limit permissible for chromium in foods by Brazilian Legislation.

  5. Portable high precision pressure transducer system

    NASA Astrophysics Data System (ADS)

    Piper, T. C.; Morgan, J. P.; Marchant, N. J.; Bolton, S. M.

    A high precision pressure transducer system for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank is presented. Since the response of the pressure transducer is temperature sensitive, it is continually housed in a battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on-board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum fluorescent display.

  6. Portable high precision pressure transducer system

    DOEpatents

    Piper, Thomas C.; Morgan, John P.; Marchant, Norman J.; Bolton, Steven M.

    1994-01-01

    A high precision pressure transducer system for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank. Since the response of the pressure transducer is temperature sensitive, it is continually housed in an battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum florescent display.

  7. Portable high precision pressure transducer system

    DOEpatents

    Piper, T.C.; Morgan, J.P.; Marchant, N.J.; Bolton, S.M.

    1994-04-26

    A high precision pressure transducer system is described for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank. Since the response of the pressure transducer is temperature sensitive, it is continually housed in an battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum fluorescent display. 2 figures.

  8. Fiber Scrambling for High Precision Spectrographs

    NASA Astrophysics Data System (ADS)

    Kaplan, Zachary; Spronck, J. F. P.; Fischer, D.

    2011-05-01

    The detection of Earth-like exoplanets with the radial velocity method requires extreme Doppler precision and long-term stability in order to measure tiny reflex velocities in the host star. Recent planet searches have led to the detection of so called "super-Earths” (up to a few Earth masses) that induce radial velocity changes of about 1 m/s. However, the detection of true Earth analogs requires a precision of 10 cm/s. One of the largest factors limiting Doppler precision is variation in the Point Spread Function (PSF) from observation to observation due to changes in the illumination of the slit and spectrograph optics. Thus, this stability has become a focus of current instrumentation work. Fiber optics have been used since the 1980's to couple telescopes to high-precision spectrographs, initially for simpler mechanical design and control. However, fiber optics are also naturally efficient scramblers. Scrambling refers to a fiber's ability to produce an output beam independent of input. Our research is focused on characterizing the scrambling properties of several types of fibers, including circular, square and octagonal fibers. By measuring the intensity distribution after the fiber as a function of input beam position, we can simulate guiding errors that occur at an observatory. Through this, we can determine which fibers produce the most uniform outputs for the severest guiding errors, improving the PSF and allowing sub-m/s precision. However, extensive testing of fibers of supposedly identical core diameter, length and shape from the same manufacturer has revealed the "personality” of individual fibers. Personality describes differing intensity patterns for supposedly duplicate fibers illuminated identically. Here, we present our results on scrambling characterization as a function of fiber type, while studying individual fiber personality.

  9. Chromium incorporation into TiO{sub 2} at high pressure

    SciTech Connect

    Escudero, Alberto; Langenhorst, Falko

    2012-06-15

    Chromium incorporation into TiO{sub 2} up to 3 GPa at 1300 Degree-Sign C and 900 Degree-Sign C has been studied by XRD as well as TEM. A CaCl{sub 2} type TiO{sub 2} polymorph has been observed in the quenched samples from high pressure. Two different mechanisms of solubility occur in the recovered samples. Chromium replaces titanium on normal octahedral sites but it also occupies interstitial octahedral sites, especially in the samples recovered from higher pressures. Interstitial chromium is responsible for an orthorhombic distortion of the TiO{sub 2} rutile structure in the quenched samples and gives rise to a (1 1 0) twinned CaCl{sub 2}-structured polymorph. This phase is very likely the result of temperature quench at high pressure. The formation of this phase is directly related to the chromium content of the TiO{sub 2} grains. Chromium solubility in TiO{sub 2} increases with increasing the synthesis pressure. TiO{sub 2} is able to accommodate up to 15.3 wt% Cr{sub 2}O{sub 3} at 3 GPa and 1300 Degree-Sign C, compared to 5.7 wt% at atmospheric pressure at the same temperature. - Graphical abstract: Microstructure consisting of twins domains of recovered Cr-doped CaCl{sub 2} type TiO{sub 2} grains synthesised at high pressure. Highlights: Black-Right-Pointing-Pointer Chromium solubility in TiO{sub 2} increases at high pressure. Black-Right-Pointing-Pointer Chromium occupies substitutional and interstitial positions in the rutile structure. Black-Right-Pointing-Pointer Interstitial chromium causes a decrease of the rutile symmetry. Black-Right-Pointing-Pointer An orthorhombic CaCl{sub 2} type structure is observed in the quenched samples.

  10. High precision tracking method for solar telescopes

    NASA Astrophysics Data System (ADS)

    Guo, Jingjing; Yang, Yunfei; Feng, Song; Ji, Kanfan; Lin, Jiaben; Zeng, Zhen; Wang, Bingxiang

    2016-07-01

    A high-precision real-time tracking method for solar telescopes was introduced in this paper based on the barycenter of full-disk solar images algorithm. To make sure the calculation was accurate and reliable, a series of strictly logic limits were set, such as setting gray threshold, judging the displacement of the barycenter and measuring the deviation from a perfect disk. A closed-loop control system was designed in the method. We located the barycenter of the full-disk images which recorded by large array CCD image sensor in real time and eliminate noise caused by bad weather, such as clouds and fog. The displacement of the barycenter was analyzed and transferred into control signal drove the motor to adjust the axis of telescope. An Ethernet interface was also provided for remote control. In the observation, the precision of this new method was better than 1″/30 minutes.

  11. High precision radial velocities with GIANO spectra

    NASA Astrophysics Data System (ADS)

    Carleo, I.; Sanna, N.; Gratton, R.; Benatti, S.; Bonavita, M.; Oliva, E.; Origlia, L.; Desidera, S.; Claudi, R.; Sissa, E.

    2016-06-01

    Radial velocities (RV) measured from near-infrared (NIR) spectra are a potentially excellent tool to search for extrasolar planets around cool or active stars. High resolution infrared (IR) spectrographs now available are reaching the high precision of visible instruments, with a constant improvement over time. GIANO is an infrared echelle spectrograph at the Telescopio Nazionale Galileo (TNG) and it is a powerful tool to provide high resolution spectra for accurate RV measurements of exoplanets and for chemical and dynamical studies of stellar or extragalactic objects. No other high spectral resolution IR instrument has GIANO's capability to cover the entire NIR wavelength range (0.95-2.45 μm) in a single exposure. In this paper we describe the ensemble of procedures that we have developed to measure high precision RVs on GIANO spectra acquired during the Science Verification (SV) run, using the telluric lines as wavelength reference. We used the Cross Correlation Function (CCF) method to determine the velocity for both the star and the telluric lines. For this purpose, we constructed two suitable digital masks that include about 2000 stellar lines, and a similar number of telluric lines. The method is applied to various targets with different spectral type, from K2V to M8 stars. We reached different precisions mainly depending on the H-magnitudes: for H ˜ 5 we obtain an rms scatter of ˜ 10 m s-1, while for H ˜ 9 the standard deviation increases to ˜ 50 ÷ 80 m s-1. The corresponding theoretical error expectations are ˜ 4 m s-1 and 30 m s-1, respectively. Finally we provide the RVs measured with our procedure for the targets observed during GIANO Science Verification.

  12. Note: High precision measurements using high frequency gigahertz signals

    NASA Astrophysics Data System (ADS)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  13. Note: High precision measurements using high frequency gigahertz signals.

    PubMed

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 10(8) to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  14. Precision mass measurements of highly charged ions

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, A. A.; Bale, J. C.; Brunner, T.; Chaudhuri, A.; Chowdhury, U.; Ettenauer, S.; Frekers, D.; Gallant, A. T.; Grossheim, A.; Lennarz, A.; Mane, E.; MacDonald, T. D.; Schultz, B. E.; Simon, M. C.; Simon, V. V.; Dilling, J.

    2012-10-01

    The reputation of Penning trap mass spectrometry for accuracy and precision was established with singly charged ions (SCI); however, the achievable precision and resolving power can be extended by using highly charged ions (HCI). The TITAN facility has demonstrated these enhancements for long-lived (T1/2>=50 ms) isobars and low-lying isomers, including ^71Ge^21+, ^74Rb^8+, ^78Rb^8+, and ^98Rb^15+. The Q-value of ^71Ge enters into the neutrino cross section, and the use of HCI reduced the resolving power required to distinguish the isobars from 3 x 10^5 to 20. The precision achieved in the measurement of ^74Rb^8+, a superallowed β-emitter and candidate to test the CVC hypothesis, rivaled earlier measurements with SCI in a fraction of the time. The 111.19(22) keV isomeric state in ^78Rb was resolved from the ground state. Mass measurements of neutron-rich Rb and Sr isotopes near A = 100 aid in determining the r-process pathway. Advanced ion manipulation techniques and recent results will be presented.

  15. High Precision Spectroscopy of Neutral Beryllium-9

    NASA Astrophysics Data System (ADS)

    Lau, Chui Yu; Williams, Will

    2015-05-01

    We report on the progress of high precision spectroscopy of the 2s2p singlet and triplet states in beryllium-9. Our goal is to improve the experimental precision on the energy levels of the 2s2p triplet J = 0, 1, and 2 states by a factor of 500, 100, and 500 respectively in order to delineate various theoretical predictions. The goal for the 2s2p singlet (J = 1) state is to improve the experimental precision on the energy level by a factor of 600 as a test of quantum electrodynamics. Our experimental setup consists of an oven capable of 1400 C that produces a collimated beam of neutral beryllium-9. The triplet states are probed with a 455 nm ECDL stabilized to a tellurium-210 line. The singlet state is probed with 235nm light from a frequency quadrupled titanium sapphire laser, where the frequency doubled light at 470 nm is stabilized to another tellurium-210 line. We also present our progress on improving the absolute accuracy of our frequency reference by using an ultrastable/low drift fiber coupled cavity.

  16. Precision timing measurements for high energy photons

    SciTech Connect

    Anderson, Dustin; Apreysan, Artur; Bornheim, Adi; Duarte, Javier; Newman, Harvey; Pena, Cristian; Ronzhin, Anatoly; Spiropulu, Maria; Trevor, Jason; Xie, Si; Zhu, Ren-Yuan

    2014-11-21

    Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

  17. High precision laser photometer for laser optics

    NASA Astrophysics Data System (ADS)

    Zhao, Yuan'an; Hu, Guohang; Cao, Zhen; Liu, Shijie; Zhu, Meiping; Shao, Jianda

    2017-06-01

    Development of laser systems requires optical components with high performance, and a high-precision double-beam laser photometer was designed and established to measure the optical performance at 1064nm. Double beam design and lock-in technique was applied to decrease the impact of light energy instability and electric noise. Pairs of samples were placed symmetrically to eliminate beam displacement, and laser scattering imaging technique was applied to determine the influence of surface defect on the optical performance. Based on the above techniques, transmittance and reflection of pairs of optics were obtained, and the measurement precision was improved to 0.06%. Different types of optical loss, such as total loss, volume loss, residual reflection and surface scattering loss, were obtained from the transmittance and reflection measurement of samples with different thickness. Comparison of optical performance of the test points with and without surface defects, the influence of surface defects on optical performance was determined. The optical performance of Nd-glass at 1064nm were measured as an example. Different types of optical loss and the influence of surface defects on the optical loss was determined.

  18. Research about the high precision temperature measurement

    NASA Astrophysics Data System (ADS)

    Lin, J.; Yu, J.; Zhu, X.; Zeng, Z.; Deng, Y.

    2012-12-01

    High precision temperature control system is one of most important support conditions for tunable birefringent filter.As the first step,we researched some high precision temperature measurement methods for it. Firstly, circuits with a 24 bit ADC as the sensor's reader were carefully designed; Secondly, an ARM porcessor is used as the centrol processing unit, it provides sufficient reading and procesing ability; Thirdly, three kinds of sensors, PT100, Dale 01T1002-5 thermistor, Wheatstone bridge(constructed by pure copper and manganin) as the senor of the temperature were tested respectively. The resolution of the measurement with these three kinds of sensors are all better than 0.001 that's enough for 0.01 stability temperature control. Comparatively, Dale 01T1002-5 thermistor could get the most accurate temperature of the key point, Wheatstone bridge could get the most accurate mean temperature of the whole layer, both of them will be used in our futrue temperature controll system.

  19. High precision innovative micropump for artificial pancreas

    NASA Astrophysics Data System (ADS)

    Chappel, E.; Mefti, S.; Lettieri, G.-L.; Proennecke, S.; Conan, C.

    2014-03-01

    The concept of artificial pancreas, which comprises an insulin pump, a continuous glucose meter and a control algorithm, is a major step forward in managing patient with type 1 diabetes mellitus. The stability of the control algorithm is based on short-term precision micropump to deliver rapid-acting insulin and to specific integrated sensors able to monitor any failure leading to a loss of accuracy. Debiotech's MEMS micropump, based on the membrane pump principle, is made of a stack of 3 silicon wafers. The pumping chamber comprises a pillar check-valve at the inlet, a pumping membrane which is actuated against stop limiters by a piezo cantilever, an anti-free-flow outlet valve and a pressure sensor. The micropump inlet is tightly connected to the insulin reservoir while the outlet is in direct communication with the patient skin via a cannula. To meet the requirement of a pump dedicated to closed-loop application for diabetes care, in addition to the well-controlled displacement of the pumping membrane, the high precision of the micropump is based on specific actuation profiles that balance effect of pump elasticity in low-consumption push-pull mode.

  20. High Precision Rovibrational Spectroscopy of OH+

    NASA Astrophysics Data System (ADS)

    Markus, Charles R.; Hodges, James N.; Perry, Adam J.; Kocheril, G. Stephen; Müller, Holger S. P.; McCall, Benjamin J.

    2016-02-01

    The molecular ion OH+ has long been known to be an important component of the interstellar medium. Its relative abundance can be used to indirectly measure cosmic ray ionization rates of hydrogen, and it is the first intermediate in the interstellar formation of water. To date, only a limited number of pure rotational transitions have been observed in the laboratory making it necessary to indirectly calculate rotational levels from high-precision rovibrational spectroscopy. We have remeasured 30 transitions in the fundamental band with MHz-level precision, in order to enable the prediction of a THz spectrum of OH+. The ions were produced in a water cooled discharge of O2, H2, and He, and the rovibrational transitions were measured with the technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy. These values have been included in a global fit of field free data to a 3Σ- linear molecule effective Hamiltonian to determine improved spectroscopic parameters which were used to predict the pure rotational transition frequencies.

  1. Highly damped kinematic coupling for precision instruments

    DOEpatents

    Hale, Layton C.; Jensen, Steven A.

    2001-01-01

    A highly damped kinematic coupling for precision instruments. The kinematic coupling provides support while causing essentially no influence to its nature shape, with such influences coming, for example, from manufacturing tolerances, temperature changes, or ground motion. The coupling uses three ball-cone constraints, each combined with a released flexural degree of freedom. This arrangement enables a gain of higher load capacity and stiffness, but can also significantly reduce the friction level in proportion to the ball radius divided by the distance between the ball and the hinge axis. The blade flexures reduces somewhat the stiffness of the coupling and provides an ideal location to apply constrained-layer damping which is accomplished by attaching a viscoelastic layer and a constraining layer on opposite sides of each of the blade flexures. The three identical ball-cone flexures provide a damped coupling mechanism to kinematically support the projection optics system of the extreme ultraviolet lithography (EUVL) system, or other load-sensitive apparatus.

  2. High Precision Isotopic Reference Material Program

    NASA Astrophysics Data System (ADS)

    Mann, J. L.; Vocke, R. D.

    2007-12-01

    Recent developments in thermal ionization and inductively coupled plasma multicollector mass spectrometers have lead to "high precision" isotope ratio measurements with uncertainties approaching a few parts in 106. These new measurement capabilities have revolutionized the study of isotopic variations in nature by increasing the number of elements showing natural variations by almost a factor of two, and new research areas are actively opening up in climate change, health, ecology, geology and forensic studies. Because the isotopic applications are impacting very diverse fields, there is at present little effective coordination between research laboratories over reference materials and the values to apply to those materials. NIST had originally developed the techniques for producing accurate isotopic characterizations, culminating in the NIST Isotopic SRM series. The values on existing materials however are insufficiently precise and, in some cases, may be isotopically heterogeneous. A new generation of isotopic standards is urgently needed and will directly affect the quality and scope of emergent applications and ensure that the results being derived from these diverse fields are comparable. A series of new isotopic reference materials similar to the NIST 3100 single element solution series is being designed for this purpose and twelve elements have been selected as having the most pressing need. In conjunction with other expert users and National Metrology Institutes, an isotopic characterization of the respective 12 selected ampoules from the NIST single element solution series is currently underway. In this presentation the preliminary results of this screening will be discussed as well as the suitability of these materials in terms of homogeneity and purity, long term stability and availability, and isotopic relevance. Approaches to value assignment will also be discussed.

  3. Aerodynamic window for high precision laser drilling

    NASA Astrophysics Data System (ADS)

    Sommer, Steffen; Dausinger, Friedrich; Berger, Peter; Hügel, Helmuth

    2007-05-01

    High precision laser drilling is getting more and more interesting for industry. Main applications for such holes are vaporising and injection nozzles. To enhance quality, the energy deposition has to be accurately defined by reducing the pulse duration and thereby reducing the amount of disturbing melting layer. In addition, an appropriate processing technology, for example the helical drilling, yields holes in steel at 1 mm thickness and diameters about 100 μm with correct roundness and thin recast layers. However, the processing times are still not short enough for industrial use. Experiments have shown that the reduction of the atmospheric pressure down to 100 hPa enhances the achievable quality and efficiency, but the use of vacuum chambers in industrial processes is normally quite slow and thus expensive. The possibility of a very fast evacuation is given by the use of an aerodynamic window, which produces the pressure reduction by virtue of its fluid dynamic features. This element, based on a potential vortex, was developed and patented as out-coupling window for high power CO II lasers by IFSW 1, 2, 3. It has excellent tightness and transmission properties, and a beam deflection is not detectable. The working medium is compressed air, only. For the use as vacuum element for laser drilling, several geometrical modifications had to be realized. The prototype is small enough to be integrated in a micromachining station and has a low gas flow. During the laser pulse, which is focussed through the potential flow, a very high fluence is reached, but the measurements have not shown any beam deflection or focal shifting. The evacuation time is below 300 ms so that material treatment with changing ambient pressure is possible, too. Experimental results have proven the positive effect of the reduced ambient pressure on the drilling process for the regime of nano- and picosecond laser pulses. Plasma effects are reduced and, because of the less absorption, the

  4. High temperature dissolution of chromium substituted nickel ferrite in nitrilotriacetic acid medium

    NASA Astrophysics Data System (ADS)

    Sathyaseelan, V. S.; Chandramohan, P.; Velmurugan, S.

    2016-12-01

    High temperature (HT) dissolution of chromium substituted nickel ferrite was carried out with relevance to the decontamination of nuclear reactors by way of chemical dissolution of contaminated corrosion product oxides present on stainless steel coolant circuit surfaces. Chromium substituted nickel ferrites of composition, NiFe(2-x)CrxO4 (x ≤ 1), was synthetically prepared and characterized. HT dissolution of these oxides was carried out in nitrilotriacetic acid medium at 160 °C. Dissolution was remarkably increased at 160 °C when compared to at 85 °C in a reducing decontamination formulation. Complete dissolution could be achieved for the oxides with chromium content 0 and 0.2. Increasing the chromium content brought about a marked reduction in the dissolution rate. About 40 fold decrease in rate of dissolution was observed when chromium was increased from 0 to 1. The rate of dissolution was not very significantly reduced in the presence of N2H4. Dissolution of oxide was found to be stoichiometric.

  5. High precision optical surface metrology using deflectometry

    NASA Astrophysics Data System (ADS)

    Huang, Run

    Software Configurable Optical Test System (SCOTS) developed at University of Arizona is a highly efficient optical metrology technique based on the principle of deflectometry, which can achieve comparable accuracy with interferometry but with low-cost hardware. In a SCOTS test, an LCD display is used to generate structured light pattern to illuminate the test optics and the reflected light is captured by a digital camera. The surface slope of test optics is determined by triangulation of the display pixels, test optics, and the camera. The surface shape is obtained by the integration of the slopes. Comparing to interferometry, which has long served as an accurate non-contact optical metrology technology, SCOTS overcomes the limitation of dynamic range and sensitivity to environment. It is able to achieve high dynamic range slope measurement without requiring null optics. In this dissertation, the sensitivity and performance of the test system have been analyzed comprehensively. Sophisticated calibrations of system components have been investigated and implemented in different metrology projects to push this technology to a higher accuracy including low-order terms. A compact on-axis SCOTS system lowered the testing geometry sensitivity in the metrology of 1-meter highly aspheric secondary mirror of Large Binocular Telescope. Sub-nm accuracy was achieved in testing a high precision elliptical X-ray mirror by using reference calibration. A well-calibrated SCOTS was successfully constructed and is, at the time of writing this dissertation, being used to provide surface metrology feedback for the fabrication of the primary mirror of Daniel K. Inouye Solar Telescope which is a 4-meter off-axis parabola with more than 8 mm aspherical departure.

  6. High temperature reactivity of two chromium-containing alloys in impure helium

    NASA Astrophysics Data System (ADS)

    Cabet, C.; Chapovaloff, J.; Rouillard, F.; Girardin, G.; Kaczorowski, D.; Wolski, K.; Pijolat, M.

    2008-04-01

    Chromium-rich nickel base alloys 617 and 230 are promising candidate materials for very high temperature gas-cooled reactors (VHTR) but they must resist corrosion in the impure primary cooling helium over very long times. The impurities of the hot helium can promote the development of chromium-rich surface oxides that appear to protect the alloys against intensive corrosion processes. However above a critical temperature (typically in the range 1173-1273 K), chromium oxide is reduced by carbon from the alloy and the surface layer is not stable anymore. Depending on the gas composition, the unprotected material rapidly either gains or loses carbon with a dramatic impact on its mechanical properties. The deleterious reaction of chromia and carbon thus fixes an ultimate reactor operating temperature. Critical temperature measurements are presented for alloys 617 and 230 and the influence of carbon monoxide partial pressure in helium is discussed.

  7. Precision mechatronics based on high-precision measuring and positioning systems and machines

    NASA Astrophysics Data System (ADS)

    Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert

    2007-06-01

    Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.

  8. High precision flux measurements with ENUBET

    NASA Astrophysics Data System (ADS)

    Pozzato, M.; ENUBET collaboration

    2017-09-01

    The challenges of precision neutrino physics (i.e the study of CP violation) require measurements of absolute ν cross sections at the GeV scale with exquisite (O(1)%) precision. Such precision is presently limited to about 10% by the uncertainties on neutrino flux at the source. A reduction of this uncertainty by one order of magnitude can be achieved monitoring the positron production in the decay tunnel originating from the Ke3 decays of charged kaons in a sign and momentum selected narrow band beam. This novel technique enables the measurement of the most relevant cross-sections for CP violation (νe and {\\displaystyle \\bar{ν }}e) with a precision of 1% and requires a special instrumented beam-line. Such non-conventional beam-line will be developed in the framework of the ENUBET Horizon-2020 Consolidator Grant (PI A. Longhin), recently approved by the European Research Council (grant agreement N° 681647). In this poster, we will present the Project and the early experimental results on ultra-compact calorimeters that can embedded in the instrumented decay tunnel.

  9. Dry Sliding Wear Behaviours of Valve Seat Inserts Produced from High Chromium White Iron

    NASA Astrophysics Data System (ADS)

    Kalyon, Ali; Özyürek, Dursun; Günay, Mustafa; Aztekin, Hasan

    2015-11-01

    In this present study, wear behaviours of high chromium white iron valve seat inserts and tappets used in the automotive sector were investigated. Wear behaviours of three different rates of high chromium white cast irons (containing 10, 12 and 14% chromium) were examined under heavy service conditions. For that purpose, the produced valve seat inserts were characterized through Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), X-ray diffraction (XRD) and hardness measurements. They were tested at a sliding speed of 1 ms-1, under 120 N load and for six different sliding distances (500, 1000, 1500, 2000, 2500, 3000 m) by using a standard wear apparatus (pin-on-disk type). The result showed that as the amount of Cr increased in the alloys, their hardness decreased. The decrease in the hardness were considered to be as the result of transformation of M7C3 carbides into M23C6 carbides in the structure. This decrease in hardness with increasing chromium content also increased the weight loss. Thus, it was determined that the white iron with 14% Cr (which had a greater amount of M23C6 carbides) was subjected to the highest wear.

  10. High precision attitude determination for Magsat

    NASA Astrophysics Data System (ADS)

    Abshire, G.; McCutcheon, R.; Summers, G.; Vanlandingham, F.; Meyers, G.

    1981-08-01

    A two phase approach to attitude determination software development is introduced. The prelaunch planning and software activities connected with the development and testing of the baseline system for processing nominal attitude data for MAGSAT are described and postlaunch analysis and modifications are outlined. Attitude data processing began 5 months after launch so that postlaunch anomalies could be accounted for. Another advantage of the two phase approach is that costs are reduced because the system is not burdened with software dealing with all possible contingencies. A definitive, continuous, time history of the three axis attitude of the spacecraft was generated to a precision of 20 arc sec (one standard deviation), in each axis. Sensor alignment determinations were done continuously because of the deletrious effects of changing alignments on attitude precision.

  11. A highly sensitive spectrophotometric determination of chromium using leuco Xylene cyanol FF.

    PubMed

    Revanasiddappa, H D; Kiran Kumar, T N

    2003-05-28

    A highly sensitive and selective spectrophotometric method was developed for the determination of trace amounts of chromium with leuco Xylene cynaol FF. The method is based on the oxidation of leuco Xylene cyanol FF (LXCFF) to its blue form of Xylene cyanol FF by chromium(VI) in sulphuric acid medium (pH 1.2-2.4), the absorbance of the formed dye is measured in an acetate buffer medium (pH 3.0-4.6) at 615 nm. The method obeys Beer's law in the concentration range of 0.05-0.45 mug ml(-l) chromium, having molar absorptivity and Sandell's sensitivity of 8.23x10(4) l mol(-1) cm(-l) and 0.00063 mug cm(-2), respectively. All the variables were studied in order to optimise the reaction conditions. The developed method has been successfully applied to the determination of chromium in steels, pharmaceutical samples, industrial effluents, natural water, and soil.

  12. High-precision triangular-waveform generator

    DOEpatents

    Mueller, T.R.

    1981-11-14

    An ultra-linear ramp generator having separately programmable ascending and decending ramp rates and voltages is provided. Two constant current sources provide the ramp through an integrator. Switching of the current at current source inputs rather than at the integrator input eliminates switching transients and contributes to the waveform precision. The triangular waveforms produced by the waveform generator are characterized by accurate reproduction and low drift over periods of several hours. The ascending and descending slopes are independently selectable.

  13. High-precision positioning of radar scatterers

    NASA Astrophysics Data System (ADS)

    Dheenathayalan, Prabu; Small, David; Schubert, Adrian; Hanssen, Ramon F.

    2016-05-01

    Remote sensing radar satellites cover wide areas and provide spatially dense measurements, with millions of scatterers. Knowledge of the precise position of each radar scatterer is essential to identify the corresponding object and interpret the estimated deformation. The absolute position accuracy of synthetic aperture radar (SAR) scatterers in a 2D radar coordinate system, after compensating for atmosphere and tidal effects, is in the order of centimeters for TerraSAR-X (TSX) spotlight images. However, the absolute positioning in 3D and its quality description are not well known. Here, we exploit time-series interferometric SAR to enhance the positioning capability in three dimensions. The 3D positioning precision is parameterized by a variance-covariance matrix and visualized as an error ellipsoid centered at the estimated position. The intersection of the error ellipsoid with objects in the field is exploited to link radar scatterers to real-world objects. We demonstrate the estimation of scatterer position and its quality using 20 months of TSX stripmap acquisitions over Delft, the Netherlands. Using trihedral corner reflectors (CR) for validation, the accuracy of absolute positioning in 2D is about 7 cm. In 3D, an absolute accuracy of up to ˜ 66 cm is realized, with a cigar-shaped error ellipsoid having centimeter precision in azimuth and range dimensions, and elongated in cross-range dimension with a precision in the order of meters (the ratio of the ellipsoid axis lengths is 1/3/213, respectively). The CR absolute 3D position, along with the associated error ellipsoid, is found to be accurate and agree with the ground truth position at a 99 % confidence level. For other non-CR coherent scatterers, the error ellipsoid concept is validated using 3D building models. In both cases, the error ellipsoid not only serves as a quality descriptor, but can also help to associate radar scatterers to real-world objects.

  14. Palladium-chromium static strain gages for high temperatures

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1992-01-01

    An electrical resistance strain gage that can provide accurate static strain measurement to a temperature of 1500 F or above is being developed both in fine wire and thin film forms. The gage is designed to be temperature compensated on any substrate material. It has a dual element: the gage element is a special alloy, palladium-13wt percent chromium (PdCr), and the compensator element is platinum (Pt). Earlier results of a PdCr based wire gage indicated that the apparent strain of this gage can be minimized and the repeatability of the apparent strain can be improved by prestabilizing the gage on the substrate for a long period of time. However, this kind of prestabilization is not practical in many applications and therefore the development of a wire gage which is prestabilized before installation on the substrate is desirable. This paper will present our recent progress in the development of a prestabilized wire gage which can provide meaningful strain data for the first thermal cycle. A weldable PdCr gage is also being developed for field testing where conventional flame-spraying installation can not be applied. This weldable gage is narrower than a previously reported gage, thereby allowing the gage to be more resistant to buckling under compressive loads. Some preliminary results of a prestabilized wire gage flame-sprayed directly on IN100, an engine material, and a weldable gage spot-welded on IN100 and SCS-6/(beta)21-S Titanium Matrix Composite (TMC), a National Aero-Space Plane (NASP) structure material, will be reported. Progress on the development of a weldable thin film gage will also be addressed. The measurement technique and procedures and the lead wire effect will be discussed.

  15. Performance capabilities of EDM of high carbon high chromium steel with copper and brass electrodes

    NASA Astrophysics Data System (ADS)

    Surekha, B.; Swain, Sudiptha; Suleman, Abu Jafar; Choudhury, Suvan Dev

    2017-07-01

    The paper address the statistical modeling of input-output relationships of electric discharge machining. In the present work, peak current (I) pulse on time (T) and gap voltage of electric discharge machining (EDM) process are chosen as control parameters to analyze the performance of the process. The output characteristics, namely radial overcut, electrode wear rate (EWR) and metal removal rate (MRR) are treated as the responses. A full factorial design (FFD) of experiments has been used to conduct the experiments and linear regression models are developed for different process characteristics. While conducting the experiments, high carbon and high chromium steel is considered as work piece material and brass and copper are used as electrode material. It is important to note that the experimental conditions are kept similar while machining with the help of different electrode materials. The data obtained from the experiments has been used to develop the regression models for three process parameters for two electrode materials.

  16. Nitrogen distribution in austenitic high-nitrogen chromium-manganese steel under friction and high-pressure torsion

    NASA Astrophysics Data System (ADS)

    Shabashov, V. A.; Korshunov, L. G.; Sagaradze, V. V.; Kataeva, N. V.; Zamatovskii, A. E.; Litvinov, A. V.; Lyashkov, K. A.

    2013-08-01

    Mössbauer spectroscopy and electron microscopic analysis were used to investigate the precipitation of products of cellular decomposition and their dissolution in high-nitrogen chromium-manganese steel FeMn22Cr18N0.8 under room-temperature severe deformation via dry sliding friction and high pressure torsion in Bridgman anvils. It has been established that the nitrogen content increases in interstitial positions in the quenched and pre-aged alloy due to the strain-induced dissolution of chromium nitrides, which are contained in the products of decomposition. Mössbauer analysis showed that the friction-induced dissolution of chromium nitrides occurs at a depth of more than 10 μm. Aging reduces the amount of nitrogen that occurred in the solid solution upon deformation. This is explained by the additional energy consumed in grinding the decomposition products.

  17. Ultra-high precision white dwarf asteroseismology

    NASA Astrophysics Data System (ADS)

    Giammichele, Noemi; Charpinet, Stéphane; Fontaine, Gilles; Brassard, Pierre; Zong, Weikai

    We present a brief progress report in our quest for deriving seismic models of pulsating white dwarfs that can account simultaneously for all the observed periods at the precision of the observations. We point out that this is possible from a pratical point of view only if parametrized models are used to complement evolutionary models. We adopt a double optimization procedure that insures that the best possible model in parameter space is found objectively and automatically. Our ultimate goal is to be able to account for the exquisite period data gathered with Kepler and Kepler-2 on key pulsating white dwarfs of both the DA (ZZ Ceti) and DB (V777 Her) type.

  18. Vertical high-precision Michelson wavemeter

    NASA Astrophysics Data System (ADS)

    Morales, A.; de Urquijo, J.; Mendoza, A.

    1993-01-01

    We have designed and tested a traveling, Michelson-type vertical wavemeter for the wavelength measurement of tunable continuous-wave lasers in the visible part of the spectrum. The interferometer has two movable corner cubes, suspending vertically from a driving setup resembling Atwood's machine. To reduce the fraction-of-fringe error, a vernier-type coincidence circuit was used. Although simple, this wavemeter has a relative precision of 3.2 parts in 109 for an overall fringe count of about 7×106.

  19. Effects of heat treatment on wear resistance and fracture toughness of duo-cast materials composed of high-chromium white cast iron and low-chromium steel

    NASA Astrophysics Data System (ADS)

    Kim, Chang Kyu; Lee, Sunghak; Jung, Jae-Young

    2006-03-01

    The objective of this study is to investigate effects of heat treatment on wear resistance and fracture toughness in duo-cast materials composed of a high-chromium white cast iron and a low-chromium steel as a wear-resistant part and a ductile part, respectively. Different size, volume fraction, and distribution of M7C3 carbides were employed in the wear-resistant part by changing the amount of chromium, and the volume fraction of martensite in the austenitic matrix was varied by the heat treatment. In the alloys containing a small amount of chromium, an interdendritic structure of eutectic M7C3 carbides was formed, and led to the improvement of wear resistance and fracture toughness. After the heat treatment, the selective wear of the matrix and the cracking or spalled-off carbides were considerably reduced since the hardness difference between carbides and matrix decreased by the increase in the matrix hardness, thereby leading to the improvement of the wear resistance. However, the fracture toughness of the heat-treated alloys was lower than that of the as-cast alloys because the matrix containing a considerable amount of martensite did not effectively prevent the crack propagation.

  20. Effect of Laser Cladding Parameters on the Microstructure and Properties of High Chromium Hardfacing Alloys

    NASA Astrophysics Data System (ADS)

    Abouda, E.; Dal, M.; Aubry, P.; Tarfa, T. N.; Demirci, I.; Gorny, C.; Malot, T.

    Mechanical components operating under high-stress and high-temperature environments require enhanced mechanical and tribological properties. In this research, different high chromium steels (Fe-Cr-C-Ni-Mo-Mn) have been coated over a 316L substrate using coaxial laser cladding. Optimized properties of the clad (such as adhesion, compactness, microstructure and dilution rate) have been obtained by a broad parameter search (laser power, powder feeding rate, scanning speed and preheating). Varying such parameters induces change in the microstructure, chemical distribution, morphology and properties of deposits. These have been thoroughly characterized in terms of metallurgical structure, phase compositions and functional properties using dedicated metallurgical mechanical and wear analysis. Samples obtained by laser cladding and plasma arc-transferred cladding have been compared. Laser cladding exhibits a significant strengthening mechanism for this hardfacing alloy. This results from a finer dendritic structure with a modified Chromium and Molybdenum precipitations distribution in the eutectic interdendritic phase.

  1. Effect of silicon on the spheroidization of cementite in hypereutectoid high carbon chromium bearing steels

    NASA Astrophysics Data System (ADS)

    Kim, Kwan-Ho; Lee, Jae-Seung; Lee, Duk-Lak

    2010-12-01

    The effect of silicon on the spheroidization of cementite in hypereutectoid high carbon chromium bearing steels has been investigated on the basis of microstructural analysis and thermodynamic calculations. The results showed that an increase of silicon content in high carbon chromium bearing steels retards the spheoridization of cementite. The thermodynamic calculations revealed that the shrinkage of the austenite phase field in bearing steels with increasing silicon content gave rise to an increase of volume fraction of cementite at an annealing temperature, possibly resulting in incomplete spheroidization. Furthermore, due to the low solubility of silicon in cementite, an increase of silicon content can raise the activity or chemical potential of carbon atoms in austenite at the austenite/cementite interfaces. Consequently, the difference in chemical potential of carbon atoms at the interfaces would be reduced with increasing silicon content, causing a decrease of the driving force for their diffusion from cementite to austenite.

  2. Adipose tissue chromium and vanadium disbalance in high-fat fed Wistar rats.

    PubMed

    Tinkov, Alexey A; Popova, Elizaveta V; Polyakova, Valentina S; Kwan, Olga V; Skalny, Anatoly V; Nikonorov, Alexandr A

    2015-01-01

    The primary objective of the current study is to investigate the relationship between adipose tissue chromium and vanadium content and adipose tissue dysfunction in a model of diet-induced obesity. A total of 26 female Wistar rats were fed either standard or high-fat diet (31.6% of fat from total caloric content) for 3 months. High-fat-feeding resulted in 21 and 33% decrease in adipose tissue chromium and vanadium content, respectively. No change was seen in hair chromium or vanadium levels. Statistical analysis revealed a significant inverse correlation of adipose tissue Cr and V with animal morphometric parameters and adipocyte size. Significant inverse dependence was observed between adipose tissue Cr and V and serum leptin and proinflammatory cytokines' levels. At the same time, adipose tissue Cr and V levels were characterized by positive correlation between serum adiponectin and adiponectin/leptin ratio. Adipose tissue Cr and V were inversely correlated (p<0.05) with insulin and homeostatic model assessment insulin resistance index (HOMA-IR) levels. Cr and V concentrations were not correlated with serum glucose in either high-fat fed or control rats; however, both serum glucose and HOMA-IR levels were significantly higher in high-fat fed, compared to control, rats. The results allow to hypothesize that impairment of adipose tissue Cr and V content plays a certain role in the development of adipose tissue endocrine dysfunction in obesity.

  3. Diffusion zone between high-chromium cast iron and high-manganese steel during electric-slag facing

    SciTech Connect

    Ponomarenko, V.P.; Shvartser, A.Y.; Stroganova, G.V.

    1986-05-01

    The authors investigate extending the service lives of components by the method of electric-slag facing of working surfaces. Steel 45 was used in the annealed state. Electric-slag remelting was the method used to determine the bending strength. Metallographic examinations were conducted under an MIM-8m microscope, while x-ray analysis of the built-up and base metals were performed on a DRON-2 diffractometer. BAsic alloying elements, chromium and manganese were studied on a ''Cameca MS-46'' microanalyzer. During the electri-slag facing of a high-chromium cast iron containing 8% of Mn on high-manganese steel 11OG13L diffusion equalization of the manganese content occurs in the fusion zone. Diffusion displacement of carbon, chromium, and manganese from high-chromium cast iron into the high-manganese steel during electric-slag facing gies rise to a smooth change in the structure of the metal in the fusion zone, and to increased strength of the joint between the unlike materials investigated.

  4. Determination of hexavalent chromium in traditional Chinese medicines by high-performance liquid chromatography with inductively coupled plasma mass spectrometry.

    PubMed

    Li, Peng; Li, Li-Min; Xia, Jing; Cao, Shuai; Hu, Xin; Lian, Hong-Zhen; Ji, Shen

    2015-12-01

    An analytical method that combined high-performance liquid chromatography with inductively coupled plasma mass spectrometry has been developed for the determination of hexavalent chromium in traditional Chinese medicines. Hexavalent chromium was extracted using the alkaline solution. The parameters such as the concentration of alkaline and the extraction temperature have been optimized to minimize the interconversion between trivalent chromium and hexavalent chromium. The extracted hexavalent chromium was separated on a weak anion exchange column in isocratic mode, followed by inductively coupled plasma mass spectrometry determination. To obtain a better chromatographic resolution and sensitivity, 75 mM NH4 NO3 at pH 7 was selected as the mobile phase. The linearity of the proposed method was investigated in the range of 0.2-5.0 μg L(-1) (r(2) = 0.9999) for hexavalent chromium. The limits of detection and quantitation are 0.1 and 0.3 μg L(-1) , respectively. The developed method was successfully applied to the determination of hexavalent chromium in Chloriti lapis and Lumbricus with satisfactory recoveries of 95.8-112.8%.

  5. Chromium Extraction via Chemical Processing of Fe-Cr Alloys Fine Powder with High Carbon Content

    NASA Astrophysics Data System (ADS)

    Torres, D. M.; Navarro, R. C. S.; Souza, R. F. M.; Brocchi, E. A.

    2017-03-01

    Ferrous alloys are important raw materials for special steel production. In this context, alloys from the Fe-Cr system, with typical Cr weight fraction ranging from 0.45 to 0.95, are prominent, particularly for the stainless steel industry. During the process in which these alloys are obtained, there is considerable production of fine powder, which could be reused after suitable chemical treatment, for example, through coupling pyrometallurgical and hydrometallurgical processes. In the present study, the extraction of chromium from fine powder generated during the production of a Fe-Cr alloy with high C content was investigated. Roasting reactions were performed at 1073 K, 1173 K, and 1273 K (800 °C, 900 °C, and 1000 °C) with 300 pct (w/w) excess NaOH in an oxidizing atmosphere (air), followed by solubilization in deionized water, selective precipitation, and subsequent calcination at 1173 K (900 °C) in order to convert the obtained chromium hydroxide to Cr2O3. The maximum achieved Cr recovery was around 86 pct, suggesting that the proposed chemical route was satisfactory regarding the extraction of the chromium initially present. Moreover, after X-ray diffraction analysis, the final produced oxide has proven to be pure Cr2O3 with a mean crystallite size of 200 nm.

  6. Chromium Extraction via Chemical Processing of Fe-Cr Alloys Fine Powder with High Carbon Content

    NASA Astrophysics Data System (ADS)

    Torres, D. M.; Navarro, R. C. S.; Souza, R. F. M.; Brocchi, E. A.

    2017-06-01

    Ferrous alloys are important raw materials for special steel production. In this context, alloys from the Fe-Cr system, with typical Cr weight fraction ranging from 0.45 to 0.95, are prominent, particularly for the stainless steel industry. During the process in which these alloys are obtained, there is considerable production of fine powder, which could be reused after suitable chemical treatment, for example, through coupling pyrometallurgical and hydrometallurgical processes. In the present study, the extraction of chromium from fine powder generated during the production of a Fe-Cr alloy with high C content was investigated. Roasting reactions were performed at 1073 K, 1173 K, and 1273 K (800 °C, 900 °C, and 1000 °C) with 300 pct (w/w) excess NaOH in an oxidizing atmosphere (air), followed by solubilization in deionized water, selective precipitation, and subsequent calcination at 1173 K (900 °C) in order to convert the obtained chromium hydroxide to Cr2O3. The maximum achieved Cr recovery was around 86 pct, suggesting that the proposed chemical route was satisfactory regarding the extraction of the chromium initially present. Moreover, after X-ray diffraction analysis, the final produced oxide has proven to be pure Cr2O3 with a mean crystallite size of 200 nm.

  7. High-Throughput Production of Chromium(III) Complexes for Antibody Immobilization.

    PubMed

    Welch, Nicholas G; Scoble, Judith A; Easton, Christopher D; Williams, Charlotte C; Bradford, Barry J; Mamedova, Laman K; Pigram, Paul J; Muir, Benjamin W

    2016-10-05

    A robot-assisted high-throughput methodology was employed to produce chromium(III) complexes suitable for the surface modification of the commercially available PerkinElmer Optiplate96 well plate for use in enzyme-linked immunosorbent assays (ELISAs). The complexes were immobilized to the native functionality of the well plate and first screened using a horseradish-peroxidase-tagged (HRP) mouse antibody to quantify binding. The top "hits" were further assessed for their ability to present the antibody in a functional state using an ELISA. "Hits" from the second screen yielded four complexes capable of improving the signal intensity of the ELISA by greater than 500%. The metal/base ratio of these complexes was also investigated, and we isolated the most stable and reproducible candidate, [Cr(OH)6](3-), which was formed from chromium(III) perchlorate and pH adjusted with ethylenediamine. This chromium solution was employed in a clinically relevant setting for the detection of bovine TNFα producing up to a 200% increase in signal intensity.

  8. High precision applications of the global positioning system

    NASA Technical Reports Server (NTRS)

    Lichten, Stephen M.

    1991-01-01

    The Global Positioning System (GPS) is a constellation of U.S. defense navigation satellites which can be used for military and civilian positioning applications. A wide variety of GPS scientific applications were identified and precise positioning capabilities with GPS were already demonstrated with data available from the present partial satellite constellation. Expected applications include: measurements of Earth crustal motion, particularly in seismically active regions; measurements of the Earth's rotation rate and pole orientation; high-precision Earth orbiter tracking; surveying; measurements of media propagation delays for calibration of deep space radiometric data in support of NASA planetary missions; determination of precise ground station coordinates; and precise time transfer worldwide.

  9. Precision Timing Calorimeter for High Energy Physics

    DOE PAGES

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; ...

    2016-04-01

    Here, we present studies on the performance and characterization of the time resolution of LYSO-based calorimeters. Results for an LYSO sampling calorimeter and an LYSO-tungsten Shashlik calorimeter are presented. We also demonstrate that a time resolution of 30 ps is achievable for the LYSO sampling calorimeter. Timing calorimetry is described as a tool for mitigating the effects due to the large number of simultaneous interactions in the high luminosity environment foreseen for the Large Hadron Collider.

  10. Two-phase chromium-niobium alloys exhibiting improved mechanical properties at high temperatures

    DOEpatents

    Liu, Chain T.; Takeyama, Masao

    1994-01-01

    The specification discloses chromium-niobium alloys which exhibit improved mechanical properties at high temperatures in the range of 1250.degree. C. and improved room temperature ductility. The alloys contain a Cr.sub.2 Nb-rich intermetallic phase and a Cr-rich phase with an overall niobium concentration in the range of from about 5 to about 18 at. %. The high temperature strength is substantially greater than that of state of the art nickel-based superalloys for enhanced high temperature service. Further improvements in the properties of the compositions are obtained by alloying with rhenium and aluminum; and additional rare-earth and other elements.

  11. Two-phase chromium-niobium alloys exhibiting improved mechanical properties at high temperatures

    DOEpatents

    Liu, C.T.; Takeyama, Masao.

    1994-02-01

    The specification discloses chromium-niobium alloys which exhibit improved mechanical properties at high temperatures in the range of 1250 C and improved room temperature ductility. The alloys contain a Cr[sub 2]Nb-rich intermetallic phase and a Cr-rich phase with an overall niobium concentration in the range of from about 5 to about 18 at. %. The high temperature strength is substantially greater than that of state of the art nickel-based superalloys for enhanced high temperature service. Further improvements in the properties of the compositions are obtained by alloying with rhenium and aluminum; and additional rare-earth and other elements. 14 figures.

  12. High-precision gauging of metal rings

    NASA Astrophysics Data System (ADS)

    Carlin, Mats; Lillekjendlie, Bjorn

    1994-11-01

    Raufoss AS designs and produces air brake fittings for trucks and buses on the international market. One of the critical components in the fittings is a small, circular metal ring, which is going through 100% dimension control. This article describes a low-price, high accuracy solution developed at SINTEF Instrumentation based on image metrology and a subpixel resolution algorithm. The measurement system consists of a PC-plugg-in transputer video board, a CCD camera, telecentric optics and a machine vision strobe. We describe the measurement technique in some detail, as well as the robust statistical techniques found to be essential in the real life environment.

  13. High precision mass measurements for wine metabolomics

    PubMed Central

    Roullier-Gall, Chloé; Witting, Michael; Gougeon, Régis D.; Schmitt-Kopplin, Philippe

    2014-01-01

    An overview of the critical steps for the non-targeted Ultra-High Performance Liquid Chromatography coupled with Quadrupole Time-of-Flight Mass Spectrometry (UPLC-Q-ToF-MS) analysis of wine chemistry is given, ranging from the study design, data preprocessing and statistical analyses, to markers identification. UPLC-Q-ToF-MS data was enhanced by the alignment of exact mass data from FTICR-MS, and marker peaks were identified using UPLC-Q-ToF-MS2. In combination with multivariate statistical tools and the annotation of peaks with metabolites from relevant databases, this analytical process provides a fine description of the chemical complexity of wines, as exemplified in the case of red (Pinot noir) and white (Chardonnay) wines from various geographic origins in Burgundy. PMID:25431760

  14. High precision mass measurements for wine metabolomics

    NASA Astrophysics Data System (ADS)

    Roullier-Gall, Chloé; Witting, Michael; Gougeon, Régis; Schmitt-Kopplin, Philippe

    2014-11-01

    An overview of the critical steps for the non-targeted Ultra-High Performance Liquid Chromatography coupled with Quadrupole Time-of-Flight Mass Spectrometry (UPLC-Q-ToF-MS) analysis of wine chemistry is given, ranging from the study design, data preprocessing and statistical analyses, to markers identification. UPLC-Q-ToF-MS data was enhanced by the alignment of exact mass data from FTICR-MS, and marker peaks were identified using UPLC-Q-ToF-MS². In combination with multivariate statistical tools and the annotation of peaks with metabolites from relevant databases, this analytical process provides a fine description of the chemical complexity of wines, as exemplified in the case of red (Pinot noir) and white (Chardonnay) wines from various geographic origins in Burgundy.

  15. Precision probes of QCD at high energies

    NASA Astrophysics Data System (ADS)

    Alioli, Simone; Farina, Marco; Pappadopulo, Duccio; Ruderman, Joshua T.

    2017-07-01

    New physics, that is too heavy to be produced directly, can leave measurable imprints on the tails of kinematic distributions at the LHC. We use energetic QCD processes to perform novel measurements of the Standard Model (SM) Effective Field Theory. We show that the dijet invariant mass spectrum, and the inclusive jet transverse momentum spectrum, are sensitive to a dimension 6 operator that modifies the gluon propagator at high energies. The dominant effect is constructive or destructive interference with SM jet production. We compare differential next-to-leading order predictions from POWHEG to public 7 TeV jet data, including scale, PDF, and experimental uncertainties and their respective correlations. We constrain a New Physics (NP) scale of 3.5 TeV with current data. We project the reach of future 13 and 100 TeV measurements, which we estimate to be sensitive to NP scales of 8 and 60 TeV, respectively. As an application, we apply our bounds to constrain heavy vector octet colorons that couple to the QCD current. We project that effective operators will surpass bump hunts, in terms of coloron mass reach, even for sequential couplings.

  16. Precision probes of QCD at high energies

    DOE PAGES

    Alioli, Simone; Farina, Marco; Pappadopulo, Duccio; ...

    2017-07-20

    New physics, that is too heavy to be produced directly, can leave measurable imprints on the tails of kinematic distributions at the LHC.We use energetic QCD processes to perform novel measurements of the Standard Model (SM) Effective Field Theory. We show that the dijet invariant mass spectrum, and the inclusive jet transverse momentum spectrum, are sensitive to a dimension 6 operator that modifies the gluon propagator at high energies. The dominant effect is constructive or destructive interference with SM jet production. Here, we compare differential next-to-leading order predictions from POWHEG to public 7TeV jet data, including scale, PDF, and experimentalmore » uncertainties and their respective correlations. Furthermore, we constrain a New Physics (NP) scale of 3.5TeV with current data. We project the reach of future 13 and 100TeV measurements, which we estimate to be sensitive to NP scales of 8 and 60TeV, respectively. As an application, we apply our bounds to constrain heavy vector octet colorons that couple to the QCD current. We conclude that effective operators will surpass bump hunts, in terms of coloron mass reach, even for sequential couplings.« less

  17. Precision timing calorimeter for high energy physics

    NASA Astrophysics Data System (ADS)

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; Duarte, Javier; Peña, Cristián; Spiropulu, Maria; Trevor, Jason; Xie, Si; Ronzhin, Anatoly

    2016-07-01

    Scintillator based calorimeter technology is studied with the aim to achieve particle detection with a time resolution on the order of a few 10 ps for photons and electrons at energies of a few GeV and above. We present results from a prototype of a 1.4×1.4×11.4 cm3 sampling calorimeter cell consisting of tungsten absorber plates and Cerium-doped Lutetium Yttrium Orthosilicate (LYSO) crystal scintillator plates. The LYSO plates are read out with wave lengths shifting fibers which are optically coupled to fast photo detectors on both ends of the fibers. The measurements with electrons were performed at the Fermilab Test Beam Facility (FTBF) and the CERN SPS H2 test beam. In addition to the baseline setup plastic scintillation counter and a MCP-PMT were used as trigger and as a reference for a time of flight measurement (TOF). We also present measurements with a fast laser to further characterize the response of the prototype and the photo sensors. All data were recorded using a DRS4 fast sampling digitizer. These measurements are part of an R&D program whose aim is to demonstrate the feasibility of building a large scale electromagnetic calorimeter with a time resolution on the order of 10 ps, to be used in high energy physics experiments.

  18. Oxidation of Palladium-Chromium Alloys for High Temperature Applications

    NASA Technical Reports Server (NTRS)

    Piltch, Nancy D.; Jih-Fen, Lei; Zeller, Mary V.

    1994-01-01

    An alloy consisting of Pd with 13 wt % Cr is a promising material for high temperature applications. High temperature performance is degraded by the oxidation of the material, which is more severe in the fine wires and thin films used for sensor applications than in the bulk. The present study was undertaken to improve our understanding of the physical and chemical changes occurring at these temperatures and to identify approaches to limit oxidation of the alloy. The alloy was studied in both ribbon and wire forms. Ribbon samples were chosen to examine the role of grain boundaries in the oxidation process because of the convenience of handling for the oxidation studies. Wire samples 25 microns in diameter which are used in resistance strain gages were studied to correlate chemical properties with observed electrical, physical, and structural properties. Overcoating the material with a metallic Cr film did prevent the segregation of Pd to the surface; however, it did not eliminate the oxidation of the alloy.

  19. Computer-Aided High Precision Verification Of Miniature Spring Structure

    NASA Astrophysics Data System (ADS)

    Bow, Sing T.; Wang, Da-hao; Chen, Tsung-sheng; Newell, Darrell E.

    1990-01-01

    A system is proposed for the high precision on-line verification of the minia-ture spring structure, including overall height, diameters of various coils as well as pitches between neighboring coils of the miniature conical springs. High preci-sion measurements without physical contact and short processing time are achieved. Deformations of any kind on the conical springs can be identified even from the worst viewing direction.

  20. System and method for high precision isotope ratio destructive analysis

    DOEpatents

    Bushaw, Bruce A; Anheier, Norman C; Phillips, Jon R

    2013-07-02

    A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

  1. Galvanometer deflection: a precision high-speed system.

    PubMed

    Jablonowski, D P; Raamot, J

    1976-06-01

    An X-Y galvanometer deflection system capable of high precision in a random access mode of operation is described. Beam positional information in digitized form is obtained by employing a Ronchi grating with a sophisticated optical detection scheme. This information is used in a control interface to locate the beam to the required precision. The system is characterized by high accuracy at maximum speed and is designed for operation in a variable environment, with particular attention placed on thermal insensitivity.

  2. Removal of High Concentration Chromium by a Foam-separating Technique Using Casein Proteins as a Foaming Reagent

    NASA Astrophysics Data System (ADS)

    Sugimoto, Futoshi

    Foam separation of high concentration chromium in leather tanning wastewater was investigated using casein protein as a foaming reagent5mL of5w/v% ammonium acetate buffer was added to the sample chromium water. After adjusting the pH to 9.0,4g/L concentrations of casein and gelatin solution were added to recovery the coagulating flocs of chromium resulting foam separation. The sample water containing chromium flocs was incased in reactor, then mixed with distilled water and 1mL of ethanol to sum 200mL total. The foam separation was performed at time intervals of 3min with an air flow rate of 300mL/min. With casein reagent, the removal rate of chromium was not influenced by the presence of NaCl, however, the rate decreased tendency using with the use of gelatin. The proposed method, utilizing 4g/L of casein solution with water, was not influenced by the presence of calcium (<34mM), magnesium (<1mM), carbonate (<0.5mM), bicarbonate (<1.2mM) nor sulfate (<350mM) ions, and is ideal for foam separation in chromium concentrations of about 100mgCr/L.

  3. High-precision camera distortion measurements with a ``calibration harp''

    NASA Astrophysics Data System (ADS)

    Tang, Zhongwei; Grompone von Gioi, Rafael; Monasse, Pascal; Morel, Jean-Michel

    2012-10-01

    This paper addresses the high precision measurement of the distortion of a digital camera from photographs. Traditionally, this distortion is measured from photographs of a flat pattern which contains aligned elements. Nevertheless, it is nearly impossible to fabricate a very flat pattern and to validate its flatness. This fact limits the attainable measurable precisions. In contrast, it is much easier to obtain physically very precise straight lines by tightly stretching good quality strings on a frame. Taking literally "plumb-line methods", we built a "calibration harp" instead of the classic flat patterns to obtain a high precision measurement tool, demonstrably reaching 2/100 pixel precisions. The harp is complemented with the algorithms computing automatically from harp photographs two different and complementary lens distortion measurements. The precision of the method is evaluated on images corrected by state-of-the-art distortion correction algorithms, and by popular software. Three applications are shown: first an objective and reliable measurement of the result of any distortion correction. Second, the harp permits to control state-of-the art global camera calibration algorithms: It permits to select the right distortion model, thus avoiding internal compensation errors inherent to these methods. Third, the method replaces manual procedures in other distortion correction methods, makes them fully automatic, and increases their reliability and precision.

  4. High Resolution and High Precision-Spectroscopy with HARPS

    NASA Astrophysics Data System (ADS)

    Pepe, F.; Lovis, C.

    Extra-solar planet search at a level of precision below 1 ms-1 sets strong requirements to the quality and stability of the wavelength solution. It also forces us to understand the effects of instrumental stability, on the one hand, and the quality of the wavelength reference, on the other hand, since both will have an impact, although in a different way, on the short- and long-term precision of the instrument. This chapter presents the calibration principles of HARPS, which lead to its extra-ordinary wavelength solution and, as a direct consequence, to its unique radial-velocity precision. In particular it will focus on the improvements of the thorium-lamp calibrations we made during the past three years, but it willl also discuss the present limitations. Finally, we give an outlook on further possible improvements which can be made in view of the extreme precision required by instruments like CODEX@ELT.

  5. Chromium and Genomic Stability

    PubMed Central

    Wise, Sandra S.; Wise, John Pierce

    2014-01-01

    Many metals serve as micronutrients which protect against genomic instability. Chromium is most abundant in its trivalent and hexavalent forms. Trivalent chromium has historically been considered an essential element, though recent data indicate that while it can have pharmacological effects and value, it is not essential. There are no data indicating that trivalent chromium promotes genomic stability and, instead may promote genomic instability. Hexavalent chromium is widely accepted as highly toxic and carcinogenic with no nutritional value. Recent data indicate that it causes genomic instability and also has no role in promoting genomic stability. PMID:22192535

  6. High precision spectroscopy and imaging in THz frequency range

    NASA Astrophysics Data System (ADS)

    Vaks, Vladimir L.

    2014-03-01

    Application of microwave methods for development of the THz frequency range has resulted in elaboration of high precision THz spectrometers based on nonstationary effects. The spectrometers characteristics (spectral resolution and sensitivity) meet the requirements for high precision analysis. The gas analyzers, based on the high precision spectrometers, have been successfully applied for analytical investigations of gas impurities in high pure substances. These investigations can be carried out both in absorption cell and in reactor. The devices can be used for ecological monitoring, detecting the components of chemical weapons and explosive in the atmosphere. The great field of THz investigations is the medicine application. Using the THz spectrometers developed one can detect markers for some diseases in exhaled air.

  7. High-precision thermal and electrical characterization of thermoelectric modules

    SciTech Connect

    Kolodner, Paul

    2014-05-15

    This paper describes an apparatus for performing high-precision electrical and thermal characterization of thermoelectric modules (TEMs). The apparatus is calibrated for operation between 20 °C and 80 °C and is normally used for measurements of heat currents in the range 0–10 W. Precision thermometry based on miniature thermistor probes enables an absolute temperature accuracy of better than 0.010 °C. The use of vacuum isolation, thermal guarding, and radiation shielding, augmented by a careful accounting of stray heat leaks and uncertainties, allows the heat current through the TEM under test to be determined with a precision of a few mW. The fractional precision of all measured parameters is approximately 0.1%.

  8. Correlation of microstructure and fracture toughness in high-chromium white iron hardfacing alloys

    SciTech Connect

    Lee, S.; Choo, S.H.; Kim, N.J.; Baek, E.R.; Ahn, S.

    1996-12-01

    A correlation is made of microstructure and fracture toughness in hypereutectic high-chromium white iron hardfacing alloys. In order to investigate the matrix effect of these alloys, in particular, four different matrices such as pearlite, austenite, and a mixture of pearlite and austenite were employed by changing the ratio of Mn/Si, while the total volume fraction of carbides was fixed. The hardfacing alloys were deposited twice on a mild steel plate by the self-shielding flux-cored arc-welding method. Fracture toughness was increased by increasing the volume fraction of austenite in the matrix, whereas hardness and abrasion resistance were nearly constant. In situ observation of the fracture process showed that cracks initiated at large primary carbides tended to be blocked at the austenitic matrix. This suggested that fracture toughness was controlled mainly by the amount of austenite in the matrix, thereby yielding the better toughness in the hardfacing alloy having the austenitic matrix. Considering both abrasion resistance and fracture toughness, therefore, the austenitic matrix was preferred for the high-chromium white iron hardfacing alloys.

  9. Correlation of microstructure and fracture toughness in high-chromium white iron hardfacing alloys

    NASA Astrophysics Data System (ADS)

    Lee, Sunghak; Choo, Seong-Hun; Kim, Nack J.; Baek, Eung-Ryul; Ahn, Sangho

    1996-12-01

    A correlation is made of microstructure and fracture toughness in hypereutectic high-chromium white iron hardfacing alloys. In order to investigate the matrix effect of these alloys, in particular, four different matrices such as pearlite, austenite, and a mixture of pearlite and austenite were employed by changing the ratio of Mn/Si, while the total volume fraction of carbides was fixed. The hardfacing alloys were deposited twice on a mild steel plate by the self-shielding flux-cored arc-welding method. Fracture toughness was increased by increasing the volume fraction of austenite in the matrix, whereas hardness and abrasion resistance were nearly constant. In situ observation of the fracture process showed that cracks initiated at large primary carbides tended to be blocked at the austenitic matrix. This suggested that fracture toughness was controlled mainly by the amount of austenite in the matrix, thereby yielding the better toughness in the hardfacing alloy having the austenitic matrix. Considering both abrasion resistance and fracture toughness, therefore, the austenitic matrix was preferred for the high-chromium white iron hardfacing alloys.

  10. A comparison of low-chromium and high-chromium reduced-activation steels for fusion applications

    SciTech Connect

    Klueh, R.L.; Maziasz, P.J.; Alexander, D.J.

    1996-11-01

    Ferritic steels have been considered candidate structural materials for first wall and blanket structures for fusion power plants since the late 1970s. The first steels considered in the United States were the conventional Cr-Mo steels Sandvik HT9 (nominally 12Cr-1Mo-0.25V-0.5W-0.5Ni-0.2C, here designated l2Cr-1MoVW), modified 9Cr-1Mo steel (9Cr-1Mo-0.2V-0.06Nb-0. IC, designated 9Cr-1MoVNb) and, to a lesser extent, 2 1/4Cr-1Mo steel (2.25Cr-Mo-0.1C). All compositions are in wt. %. The normalized-and-tempered 9 and 12Cr steels had a tempered martensite microstructure, and the normalized-and-tempered 2 1/4 Cr steel had a tempered bainite microstructure. This report describes chromium steels tested in normalized and tempered conditions. Miniature tensile and Charpy specimens were tested.

  11. Effects of Si on the Microstructures and Mechanical Properties of High-Chromium Cast Iron

    NASA Astrophysics Data System (ADS)

    Lai, J. P.; Pan, Q. L.; Peng, H. J.; Cui, H. R.; Xiao, C. A.

    2016-11-01

    Effect of Si on the microstructures and mechanical properties of high-chromium cast iron was investigated. The eutectic carbides are refined greatly and a transformation of matrix from austenitic matrix to pearlite is observed with increase in Si content from 0.5 to 1.5 wt.%. The refinement of eutectic microstructure is attributed to the decrease in the eutectic temperature, while the transformation from austenite matrix to pearlite is associated with the increase in solubility of carbon in the matrix. In the pearlite matrix, two types of pearlite are observed: one with lamellar pearlite, distributing at the periphery, and the second one with granular pearlite at the center. The density of secondary carbides precipitated from the matrix increases greatly with addition of Si from 0.5 to 1.5 wt.%, which is associated with more carbon and chromium elements confined in the matrix in the alloy containing 1.5 wt.%. More rod-like particles are observed in the alloy containing 0.5 wt.% Si, while the morphology of secondary carbides of alloy containing 1.5 wt.% is granular. The mechanical properties are improved with a 7% increase in tensile strength from 586 to 626 MPa and impact toughness from 5.8 to 7.3 J cm-2.

  12. Design and control of a high precision drive mechanism

    NASA Astrophysics Data System (ADS)

    Pan, Bo; He, Yongqiang; Wang, Haowei; Zhang, Shuyang; Zhang, Donghua; Wei, Xiaorong; Jiang, Zhihong

    2017-01-01

    This paper summarizes the development of a high precision drive mechanism (HPDM) for space application, such as the directional antenna, the laser communication device, the mobile camera and other pointing mechanisms. In view of the great practical significance of high precision drive system, control technology for permanent magnet synchronous motor (PMSM) servo system is also studied and a PMSM servo controller is designed in this paper. And the software alignment was applied to the controller to eliminate the steady error of the optical encoder, which helps to realize the 1 arcsec (1σ) control precision. To assess its capabilities, the qualification environment testing including the thermal vacuum cycling testing, and the sinusoidal and random vibration were carried out. The testing results show that the performance of the HPDM is almost the same between the former and the end of each testing.

  13. High-precision spectroscopy of hydrogen molecular ions

    NASA Astrophysics Data System (ADS)

    Zhong, Zhen-Xiang; Tong, Xin; Yan, Zong-Chao; Shi, Ting-Yun

    2015-05-01

    In this paper, we overview recent advances in high-precision structure calculations of the hydrogen molecular ions ( and HD+), including nonrelativistic energy eigenvalues and relativistic and quantum electrodynamic corrections. In combination with high-precision measurements, it is feasible to precisely determine a molecular-based value of the proton-to-electron mass ratio. An experimental scheme is presented for measuring the rovibrational transition frequency (v,L) : (0,0) → (6,1) in HD+, which is currently underway at the Wuhan Institute of Physics and Mathematics. Project supported by the National Natural Science Foundation of China (Grants Nos. 11474316, 11004221, 10974224, and 11274348), the “Hundred Talent Program” of Chinese Academy of Sciences. Yan Zong-Chao was supported by NSERC, SHARCnet, ACEnet of Canada, and the CAS/SAFEA International Partnership Program for Creative Research Teams.

  14. Precision glass molding: an integrative approach for the production of high precision micro-optics

    NASA Astrophysics Data System (ADS)

    Hünten, Martin; Klocke, Fritz; Dambon, Olaf

    2010-02-01

    Miniaturization and integration are the dominating factors for the success of numerous optical devices. Conventional manufacturing processes for the fabrication of precise glass optics by means of grinding and polishing cannot cope the increasing demands in terms of precision, volume and costs. Here, precision glass molding is the enabling technology to meet these demands of the future optical products and applications. Since the market requests further miniaturization and integration of the micro optical components the possession of the entire sequence of processes is absolutely essential. With the accomplished and ongoing developments at the Fraunhofer IPT, the replication of double-sided (a)spherical and (a)cylindrical glass lenses with form accuracies of < 150 nm as well as lens arrays and even freeform optics could be realized. Therefore, a sequence of processes needs to be passed. The FEM-simulation of the molding process which was driven to a point capable to simulate even the molding of freeform optics is the first process step. Further on, new mold design concepts were generated to enable the replication of free formed optics. The research works focusing on the mold manufacturing led to sophisticated grinding process strategies able to realized complex mold geometries such as lens arrays. With regard to the coating of the molds, proceedings were developed assuring a defect free and uniform coating which enables the longevity of the molds and therewith helps reducing the final costs per lens. Thus, the precision glass molding becomes more and more interesting even for highly complex mid volume lots, characteristic for European or US optics manufacturer.

  15. High precision radial velocities: the case for NIR.

    NASA Astrophysics Data System (ADS)

    Carleo, I.; Gratton, R.

    In the context of the preparation for the high resolution spectrograph HIRES for E-ELT, we are studying the possibility to derive high-precision radial velocities (RV) on a prototype:GIANO, the near-infrared (NIR) echelle spectrograph now available at the Telescopio Nazionale Galileo. Radial velocities measured from near-infrared spectra are a potential tool to search for extrasolar planets around cool stars. High resolution infrared spectrographs now available are reaching the high precision of visible instruments, with a constant improvement over time. In particular, no other IR instruments have GIANO's capability to cover the entire NIR wavelength range. We have developed an ensemble of IDL procedures to measure high precision radial velocities on GIANO spectra. Taking into account the achieved precisions with GIANO, we constrain the sample of targets for which GIANO is better than HARPS-N, but with the advent of GIARPS (GIANO+HARPS-N), GIANO will improve its performances and include a much larger sample of stars. The NIR range is the future of RV measurements, especially because the jitter due to the star surface activities is reduced in the NIR. As a consequence, HIRES working in NIR range might be very useful, and for a wide range of cases, it will be more efficient than HIRES working in the visible range, for detection and characterization of planets using radial velocity technique.

  16. Mossbauer analysis of deformation dissolution of the products of cellular decomposition in high-nitrogen chromium manganese austenite steel

    NASA Astrophysics Data System (ADS)

    Shabashov, V. A.; Korshunov, L. G.; Sagaradze, V. V.; Kataeva, N. V.; Zamatovsky, A. E.; Litvinov, A. V.; Lyashkov, K. A.

    2014-03-01

    Methods of Mossbauer spectroscopy and electron microscopy analysis of high-nitrogen chromium manganese steel FeMn22Cr18N0.8 have been used to investigate the processes of dissolution of the products of cellular decomposition in austenite matrix upon severe deformation under the conditions of dry sliding friction and shear under pressure in Bridgman anvils. Deformation-induced redistribution of nitrogen from the chromium nitrides to interstitial positions of the quenched and preliminary aged steel has been determined. According to the data of Mossbauer analysis the depth of dissolution of chromium nitrides and the increase of content of nitrogen in steel matrix upon friction is 10 μn and more. Aging decreases the amount of nitrogen which transfers to the solid solution under deformation. This is a factor of the enhanced adhesive wear in the aged samples.

  17. SENSITIVITY OF HANFORD IMMOBILIZED HIGH LEVEL WASTE (IHLW) GLASS MASS TO CHROMIUM & ALUMINUM PARTITIONING ASSUMPTIONS

    SciTech Connect

    CERTA, P.J.

    2004-06-07

    The strategy for the treatment of the Hanford Site tank wastes involves water and caustic washing of the tank waste sludges to reduce sludge mass and the corresponding mass of high-level waste (HLW) glass that will be generated by the Waste Treatment and Immobilization Plant (WTP). During fiscal year (FY) 2003 CH2M HILL Hanford Group, Inc. (CH2M HILL) developed revised water wash and caustic leach factors for chromium (RPP-10222) and aluminum (RPP-11079) to estimate the waste treatment behavior of the tank waste compositions. Subsequently, the U.S. Department of Energy, Office of River Protection (ORP) requested that CH2M HILL evaluate the potential impacts to the HLW glass mass due to these revised water wash and caustic leach factors. ORP plans to use the results of this study in conjunction with separate information regarding the process impacts of implementing oxidative leaching at the WTP to determine whether oxidative leaching is adequate to mitigate potential increases in HLW glass production or whether additional strategies are required. The purpose of this sensitivity study of immobilized HLW glass mass to chromium and aluminum partitioning assumptions was to: (1) Identify the impacts of the revised water wash and caustic leach factors for chromium and aluminum on the mass of HLW glass. (2) Understand the effect of oxidative leaching on the mass of HLW glass. (3) Identify the major influences for HLW glass mass and waste blending. (4) Characterize the degree of pretreatment (water washing, caustic leaching, and oxidative leaching) assumed for different source tanks. (5) Identify candidate tanks for opportunistic sampling and testing to confirm the inventory and better understand the behavior of chromium during retrieval, staging, and subsequent processing. The study concluded that: (1) Application of the revised chromium and aluminum wash and leach factors will increase the HLW glass mass by about 60 to 100 percent (using the relaxed glass properties model

  18. Formation of Superhexagonal Chromium Hydride by Exposure of Chromium Thin Film to High Temperature, High Pressure Hydrogen in a Ballistic Compressor.

    NASA Astrophysics Data System (ADS)

    Pan, Yi.

    This dissertation describes a novel, non-equilibrium method which was used to synthesize a new chromium hydride phase. Single crystal, body centered cubic Cr thin films were prepared by vacuum evaporation. These films were exposed to high temperature (close to the melting point of Cr), high pressure hydrogen gas in a ballistic compressor. This was followed by rapid cooling (>10^5^ circC/s) to room temperature. Using the transmission electron microscope (TEM), second phase particles of superhexagonal structure, which has lattice constant A = 4.77A and C/A = 1.84, are found in the films. This structure has a volume per Cr atom slightly larger than that of hexagonal closed packed CrH, so that the superhexagonal structure may contain more hydrogen than the hexagonal close packed CrH. The superhexagonal particles have a definite orientation relationship with the matrix: (021) _{rm sh} // (001) _{rm b} and (212)_{rm sh} // (110)_{rm b} . The superhexagonal structure is quite stable in air and at room temperature, but decomposes to body centered cubic Cr when bombarded by the electron beam in the TEM. No such particles were observed in Cr films exposed to pure argon under similar conditions in the ballistic compressor. Positive identification of hydrogen content was obtained by high-temperature vacuum extraction in a discharge tube. After vacuum extraction, hydrogen spectrum was observed, and the intensity of electron diffraction from superhexagonal structure decreased. Using an energy dispersive spectrometer with the capability of detecting elements down to atomic number six (carbon), no changes in composition of the films were found by comparing the characteristic x-ray spectra of the same film before and after exposure to hot, dense hydrogen in the ballistic compressor. This result suggests that this non-equilibrium method may be used for other metal-hydrogen system to obtain new structural phases that are of scientific or technological interest.

  19. Autowave process of the localized plastic deformation of high-chromium steel saturated with hydrogen

    NASA Astrophysics Data System (ADS)

    Bochkareva, A. V.; Barannikova, S. A.; Li, Yu V.; Lunev, A. G.; Zuev, L. B.

    2016-06-01

    The deformation behavior of high-chromium stainless steel of sorbitic structure upon high-temperature tempering and of electrically saturated with hydrogen in the electrochemical cell during 12 hours is investigated. The stress-strain curves for each state were obtained. From the stress-strain curves, one can conclude that hydrogen markedly reduces the elongation to the fracture of specimen. Using double-exposed speckle photography method it was found that the plastic flow of the material is of a localized character. The pattern distribution of localized plastic flow domains at the linear hardening stage was investigated. Comparative study of autowave parameters was carried out for the tempered steel as well as the electrically saturated with hydrogen steel.

  20. Electric Quadrupole Transition Measurements of Hydrogen Molecule with High Precision

    NASA Astrophysics Data System (ADS)

    Cheng, Cun-Feng; Wang, Jin; Tan, Yan; Liu, An-Wen; Hu, Shui-Ming

    2013-06-01

    Molecular hydrogen is the most fundamental, and the only neutral molecule expected to be both calculated and measured with extremely high accuracy. High-precision measurements of its spectroscopy, especially the levels at the electric ground state, play an important role in the examination of precise quantum chemistry calculations and some fundamental physical constants. In the infrared region, H_2, being a homonuclear diatomic molecule, only has very weak electric quadrupole transitions. We established a new spectroscopy approach with ultra-high precision and sensitivity as well, based on a laser-locked cavity ring-down spectrometer. An equivalent absorption path-length of thousands of kilometers and a frequency precision of 10^{-5} cm^{-1} have been achieved. Ro-vibrational spectra of the second overtone of H_2 have been recorded. The obtained results will provide a direct examination of the high-accuracy quantum theory. It also shades light on the determination of fundamental physical constants such as the electron/proton mass ratio in a molecular system.

  1. VIEW OF MICROMACHINING, HIGH PRECISION EQUIPMENT USED TO CUSTOM MAKE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF MICRO-MACHINING, HIGH PRECISION EQUIPMENT USED TO CUSTOM MAKE SMALL PARTS. LUMPS OF CLAY; SHOWN IN THE PHOTOGRAPH, WERE USED TO STABILIZE PARTS BEING MACHINED. (11/1/87) - Rocky Flats Plant, Stainless Steel & Non-Nuclear Components Manufacturing, Southeast corner of intersection of Cottonwood & Third Avenues, Golden, Jefferson County, CO

  2. Fabrication and metrology of high-precision freeform surfaces

    NASA Astrophysics Data System (ADS)

    Supranowitz, Chris; Dumas, Paul; Nitzsche, Tobias; DeGroote Nelson, Jessica; Light, Brandon B.; Medicus, Kate; Smith, Nathan

    2013-09-01

    Freeform applications are growing and include helmet-mounted displays, conformal optics (e.g. windows integrated into airplane wings), and those requiring the extreme precision of EUV. These non-rotationally symmetric surfaces pose challenges to optical fabrication, mostly in the areas of polishing and metrology. The varying curvature of freeform surfaces drives the need for smaller, more "conformal", tools for polishing and reference beams for interferometry. In this paper, we present fabrication results of a high-precision freeform surface. We will discuss the total manufacturing process, including generation, pre-polishing, MRF®, and metrology, highlighting the capabilities available in today's optical fabrication companies.

  3. GENERATION AND CONTROL OF HIGH PRECISION BEAMS AT LEPTON ACCELERATORS

    SciTech Connect

    Yu-Chiu Chao

    2007-06-25

    Parity violation experiments require precision manipulation of helicity-correlated beam coordinates on target at the nm/nrad-level. Achieving this unprecedented level of control requires a detailed understanding of the particle optics and careful tuning of the beam transport to keep anomalies from compromising the design adiabatic damping. Such efforts are often hindered by machine configuration and instrumentation limitations at the low energy end. A technique has been developed at CEBAF including high precision measurements, Mathematica-based analysis for obtaining corrective solutions, and control hardware/software developments for realizing such level of control at energies up to 5 GeV.

  4. High precision u/th dating of first Polynesian settlement.

    PubMed

    Burley, David; Weisler, Marshall I; Zhao, Jian-xin

    2012-01-01

    Previous studies document Nukuleka in the Kingdom of Tonga as a founder colony for first settlement of Polynesia by Lapita peoples. A limited number of radiocarbon dates are one line of evidence supporting this claim, but they cannot precisely establish when this event occurred, nor can they afford a detailed chronology for sequent occupation. High precision U/Th dates of Acropora coral files (abraders) from Nukuleka give unprecedented resolution, identifying the founder event by 2838±8 BP and documenting site development over the ensuing 250 years. The potential for dating error due to post depositional diagenetic alteration of ancient corals at Nukuleka also is addressed through sample preparation protocols and paired dates on spatially separated samples for individual specimens. Acropora coral files are widely distributed in Lapita sites across Oceania. U/Th dating of these artifacts provides unparalleled opportunities for greater precision and insight into the speed and timing of this final chapter in human settlement of the globe.

  5. The advancement of the high precision stress polishing

    NASA Astrophysics Data System (ADS)

    Li, Chaoqiang; Lei, Baiping; Han, Yu

    2016-10-01

    The stress polishing is a kind of large-diameter aspheric machining technology with high efficiency. This paper focuses on the principle, application in the processing of large aspheric mirror, and the domestic and foreign research status of stress polishing, aimed at the problem of insufficient precision of mirror surface deformation calculated by some traditional theories and the problem that the output precision and stability of the support device in stress polishing cannot meet the requirements. The improvement methods from these three aspects are put forward, the characterization method of mirror's elastic deformation in stress polishing, the deformation theory of influence function and the calculation of correction force, the design of actuator's mechanical structure. These improve the precision of stress polishing and provide theoretical basis for the further application of stress polishing in large-diameter aspheric machining.

  6. High Precision Differential Photometry with CCDs: A Brief History

    NASA Astrophysics Data System (ADS)

    Howell, Steve B.

    I present a brief history of the hunt for high photometric precision using CCDs in astronomy. CCDs were invented in 1969 and only 7 years later they started to appear at the major observatories of the time. The next 10 years constituted a steep learning curve for astronomers as they developed an understanding of CCDs as instruments and analysis techniques for use with digital images. In 1985, differential photometry with CCDs began producing light curves with precisions near 0.01 magnitude. By 2008, ground-based telescopes armed with CCDs and using differential techniques consistently can provide photometric precisions of 1 millimagnitude or better. The challenge now is to continue to improve the photometry using new types of CCD detectors and other advanced digital imagers.

  7. Pulsed-field ionization spectroscopy of high Rydberg states (n=50-200) of bis(ɛ6-benzene)chromium

    NASA Astrophysics Data System (ADS)

    Choi, Kyo-Won; Choi, Sunyoung; Baek, Sun Jong; Kim, Sang Kyu

    2007-01-01

    The ionization behavior of the high Rydberg states of bis(η6-benzene)chromium in the presence of ac and/or dc fields has been explored. The application of an ac scrambling field at the time of laser excitation lengthens the lifetime of the Rydberg state by almost two orders of magnitude. The lifetime enhancement by the scrambling field is much more effective for n <100 than it is for n >100 Rydberg states. The pulsed-field ionization of Rydberg states of n <100 shows the typical diabatic ionization behavior for low n. The two distinct ionization behaviors observed for the relatively low (n=50-100) and high (n=100-200) Rydberg states suggest that the former originate from the optically accessed nf Rydberg series, whereas the latter are due to np Rydberg series. Based on the understanding of the ionization behavior of bis(η6-benzene)chromium, the accurate ionization potential is deduced to give IP =5.4665±0.0003eV. Optimization of the various electric field conditions greatly enhances the spectral sensitivity of the mass-analyzed threshold ionization (MATI) spectroscopy. The high-resolution MATI spectrum of the title molecule obtained here provides precise cationic vibrational frequencies for many skeletal and benzene ring modes. A number of vibrational modes are newly identified, and the ambiguity regarding to some mode assignments is now clearly resolved through the Frank-Condon analysis based on ab initio calculations.

  8. Impact of chromium histidinate on high fat diet induced obesity in rats

    PubMed Central

    2011-01-01

    Background Chromium (Cr) is an essential trace element that has garnered interest for use as a weight loss aid, but its molecular mechanism in obesity is not clear. In this study, an attempt has been made to investigate the effects of chromium histidinate (CrHis) on glucose transporter-2 (GLUT-2), nuclear factor erythroid 2-related factor 2 (Nrf2), heme oxygenase-1 (HO-1), nuclear factor-kappa B (NF-κB p65) and the oxidative stress marker 4-hydroxynonenal adducts (HNE) expressions in liver of rats fed high fat diet (HFD). Methods Male Wistar rats (n = 40, 8 wk-old) were divided into four groups. Group I was fed a standard diet (12% of calories as fat); Group II was fed a standard diet and supplemented with 110 μg CrHis/kg BW/d; Group III was fed a HFD (40% of calories as fat); Group IV was fed HFD and supplemented with 110 μg CrHis/kg BW/d. Results Rats fed HFD possessed greater serum insulin (40 vs.33 pmol/L) and glucose (158 vs. 143 mg/dL) concentration and less liver Cr (44 vs.82 μg/g) concentration than rats fed the control diet. However, rats supplemented with CrHis had greater liver Cr and serum insulin and lower glucose concentration in rats fed HFD (P < 0.05). The hepatic nuclear factor-kappa B (NF-κB p65) and HNE were increased in high fat group compared to control group, but reduced by the CrHis administration (P < 0.05). The levels of hepatic Nrf2 and HO-1 were increased by supplementation of CrHis (P < 0.05). Conclusion These findings demonstrate that supplementation of CrHis is protective against obesity, at least in part, through Nrf2-mediated induction of HO-1 in rats fed high fat diet. PMID:21539728

  9. Process for forming adherent chromium electrodeposits from high energy efficient bath on ferrous metal substrates

    SciTech Connect

    McCullen, W.H.; Chessin, H.; Jones, A.R.

    1986-04-29

    A method is described of forming an adherent chromium deposit on a metal substrate comprising the steps of: (a) activating the substrate by electrolytically etching in an activation solution consisting essentially of a substantially neutral solution of an alkali metal sulfate, and (b) electrodepositing chromium on the thus-activated substrate.

  10. Oral administration of the high-chromium yeast improve blood plasma variables and pancreatic islet tissue in diabetic mice.

    PubMed

    Liu, Lu; Jin, Wen; Lv, Jia-Ping

    2010-12-01

    The in vivo effects of oral administration of the high-chromium yeast to healthy and diabetic mice are described. Given that these complexes are proposed to function by potentiating the actions of insulin and activating the insulin receptor kinase, changes in lipid and carbohydrate metabolism would be expected. After 15 weeks administration (500 μg Cr/kg body mass) to healthy mice, abnormal metabolism and pathological change were not observed. After 15 weeks of treatment (0-1,000 μg Cr/kg body mass) of diabetic mice, the effect of high-chromium yeast on blood lipids and blood glycosylated hemoglobin (GHb) of diabetes are not consistent. High-chromium yeast results in a lowering (P < 0.05) of GHb and triglyceride, lowering (P < 0.01) of total cholesterol, and restoration (P < 0.01) of insulin; these results are in stark contrast to those of diabetic mice of administration of normal yeast, which have no effect on these parameters and serve as control group. The histopathological analysis of pancreas islet shows that high-chromium yeast could profoundly protect the impaired pancreatic islet and β-cells from inflammatory infiltration and fibrosis.

  11. Study of Chromium-Frit-Type Coatings for High-Temperature Protection of Molybdenum

    NASA Technical Reports Server (NTRS)

    Moore, D G; Bolz, L H; Pitts, J W; Harrison, W N

    1951-01-01

    The achievement of more compact and efficient power plants for aircraft is dependent, among other factors, on the perfection of heat-resisting materials that are superior to those in current use. Molybdenum is one of the high-melting metals (melting point, 4750 F). It is fairly abundant and also can be worked into many of the shapes required in modern power plants. To permit its widespread use at elevated temperatures, however, some means must first be found to prevent its rapid oxidation. The application of a protective coating is one method that might be used to achieve this goal. In the present work, a number of chromium-frit-type coatings were studied. These were bonded to molybdenum specimens by firing in controlled atmospheres to temperatures in the range of 2400 to 2700 F.

  12. Precision glass molding of high-resolution diffractive optical elements

    NASA Astrophysics Data System (ADS)

    Prater, Karin; Dukwen, Julia; Scharf, Toralf; Herzig, Hans P.; Plöger, Sven; Hermerschmidt, Andreas

    2016-04-01

    The demand of high resolution diffractive optical elements (DOE) is growing. Smaller critical dimensions allow higher deflection angles and can fulfill more demanding requirements, which can only be met by using electron-beam lithography. Replication techniques are more economical, since the high cost of the master can be distributed among a larger number of replicas. The lack of a suitable mold material for precision glass molding has so far prevented an industrial use. Glassy Carbon (GC) offers a high mechanical strength and high thermal strength. No anti-adhesion coatings are required in molding processes. This is clearly an advantage for high resolution, high aspect ratio microstructures, where a coating with a thickness between 10 nm and 200 nm would cause a noticeable rounding of the features. Electron-beam lithography was used to fabricate GC molds with highest precision and feature sizes from 250 nm to 2 μm. The master stamps were used for precision glass molding of a low Tg glass L-BAL42 from OHARA. The profile of the replicated glass is compared to the mold with the help of SEM images. This allows discussion of the max. aspect-ratio and min. feature size. To characterize optical performances, beamsplitting elements are fabricated and their characteristics were investigated, which are in excellent agreement to theory.

  13. High Precision Photometry for the K2 Mission

    NASA Astrophysics Data System (ADS)

    Huang, Xu; Soares-Furtado, Melinda; Penev, Kaloyan; Hartman, Joel; Bakos, Gaspar; Bhatti, Waqas; Domsa, Istvan; de Val-Borro, Miguel

    2015-12-01

    The two reaction wheel K2 mission brings new challenges for the data reduction processes. We developed a reduction pipeline for extracting high precision photometry from the K2 dataset and we use this pipeline to generate light curves for the K2 Campaign 0 super-stamps and K2 Campaign 1 target pixel dataset. Key to our reduction technique is the derivation of global astrometric solutions from the target stamps from which accurate centroids are passed on for high precision photometry extraction. We also implemented the image subtraction method to reduce the K2 Campaign 0 super-stamps containing open clusters M35 and NGC2158. We extract target light curvesfor sources from a combined UCAC4 and EPIC catalogue -- this includes not only primary targets of the K2 Mission, but also other stars that happen to fall on the pixel stamps. Our astrometric solutions achieve a median residual of ~0.127". For bright stars, our best 6.5 hour precision for raw light curves is ~20 parts per million (ppm). For our detrended light curves, the best 6.5 hour precision achieved is ~15 ppm. We show that our detrended light curves have fewer systematic effects (or trends, or red-noise) than light curves produced by other groups from the same observations. We highlight the measurements of rotation curves using the K2 light curves of stars within open cluster M35 and NGC2158.

  14. Design of high-precision ranging system for laser fuze

    NASA Astrophysics Data System (ADS)

    Chen, Shanshan; Zhang, He; Xu, Xiaobin

    2016-10-01

    According to the problem of the high-precision ranging in the circumferential scanning probe laser proximity fuze, a new type of pulsed laser ranging system has been designed. The laser transmitting module, laser receiving module and ranging processing module have been designed respectively. The factors affecting the ranging accuracy are discussed. And the method of improving the ranging accuracy is studied. The high-precision ranging system adopts the general high performance microprocessor C8051FXXX as the core. And the time interval measurement chip TDC-GP21 was used to implement the system. A PCB circuit board was processed to carry on the experiment. The results of the experiment prove that a centimeter level accuracy ranging system has been achieved. The works can offer reference for ranging system design of the circumferential scanning probe laser proximity fuze.

  15. High-precision Photogrammetric Surface Figure Measurements under Cryogenic Environment

    NASA Astrophysics Data System (ADS)

    Lou, Z.; Qian, Y.; Fan, S. H.; Liu, C. R.; Wang, H. R.; Zuo, Y. X.; Cheng, J. Q.; Yang, J.

    2016-01-01

    Limited by the working temperature of the measurement equipments, most of the high-precision surface figure measurement techniques cannot be applied under a cryogenic environment. This paper reports the first attempt to measure the surface figure of a high-precision terahertz reflector panel under low temperatures based on photogrammetry. The measurement employs a high resolution industrial camera sitting on an automatic experimental platform which enables photos been taken in an automatic fashion inside a climate chamber. A repeatable accuracy of 2.1 μm rms is achieved under the cryogenic environment. Furthermore, surface figure measured by a three-coordinate measuring machine under room temperature is used to calibrate the thickness variation of the paper targets. By this technique, the surface figure of an aluminum prototype panel of the 5 meter Dome A Terahertz Telescope (DATE5) is measured from room temperature down to -55°C.

  16. Preparation of cold molecules for high-precision measurements

    NASA Astrophysics Data System (ADS)

    Wall, T. E.

    2016-12-01

    Molecules can be used to test fundamental physics. Such tests often require cold molecules for detailed spectroscopic analysis. Cooling internal degrees of freedom provides a high level of state-selectivity, with large populations in the molecular states of interest. Cold translational motion allows slow, bright beams to be created, allowing long interaction times. In this tutorial article we describe the common techniques for producing cold molecules for high-precision spectroscopy experiments. For each technique we give examples of its application in experiments that use molecular structure to probe fundamental physics, choosing one experiment in particular as a case study. We then discuss a number of new techniques, some currently under development, others proposed, that promise high flux sources of cold molecules applicable to precise spectroscopic tests of fundamental physics.

  17. Compound-specific hydrogen isotope analysis of heteroatom-bearing compounds via gas chromatography-chromium-based high-temperature conversion (Cr/HTC)-isotope ratio mass spectrometry.

    PubMed

    Renpenning, Julian; Kümmel, Steffen; Hitzfeld, Kristina L; Schimmelmann, Arndt; Gehre, Matthias

    2015-09-15

    The traditional high-temperature conversion (HTC) approach toward compound-specific stable isotope analysis (CSIA) of hydrogen for heteroatom-bearing (i.e., N, Cl, S) compounds has been afflicted by fractionation bias due to formation of byproducts HCN, HCl, and H2S. This study presents a chromium-based high-temperature conversion (Cr/HTC) approach for organic compounds containing nitrogen, chlorine, and sulfur. Following peak separation along a gas chromatographic (GC) column, the use of thermally stable ceramic Cr/HTC reactors at 1100-1500 °C and chemical sequestration of N, Cl, and S by chromium result in quantitative conversion of compound-specific organic hydrogen to H2 analyte gas. The overall hydrogen isotope analysis via GC-Cr/HTC-isotope ratio mass spectrometry (IRMS) achieved a precision of better than ± 5 mUr along the VSMOW-SLAP scale. The accuracy of GC-Cr/HTC-IRMS was validated with organic reference materials (RM) in comparison with online EA-Cr/HTC-IRMS and offline dual-inlet IRMS. The utility and reliability of the GC-Cr/HTC-IRMS system were documented during the routine measurement of more than 500 heteroatom-bearing organic samples spanning a δ(2)H range of -181 mUr to 629 mUr.

  18. Solidification and solid-state transformation mechanisms in Si alloyed high-chromium white cast irons

    NASA Astrophysics Data System (ADS)

    Laird, George; Powell, Graham L. F.

    1993-04-01

    Chromium white cast irons are widely used in environments where severe abrasion resistance is a dominant requirement. To improve the wear resistance of these commercially important irons, the United States Bureau of Mines and CSIRO Australia are studying their solidification and solid-state transformation kinetics. A ternary Fe-Cr-C iron with 17.8 wt pct (pct) Cr and 3.0 pct C was compared with commercially available irons of similar Cr and C contents with Si contents between 1.6 and 2.2 pct. The irons were solidified and cooled at rates of 0.03 and 0.17 K · s-1 to 873 K. Differential thermal analysis (DTA) showed that Si depresses the eutectic reaction temperature and suggests that is has no effect upon the volume of eutectic carbides formed during solidification. Microprobe analysis revealed that austenite dendrites within the Si alloyed irons cooled at 0.03 and 0.17 K·s-1 had C and Cr contents that were lower than those of dendrites within the ternary alloy cooled at the same cooling rate and a Si alloyed iron that was water quenched from the eutectic temperature. These lower values were shown by image analysis to be the result of both solid-state growth (coarsening) of the eutectic carbides and some secondary carbide formation. Hardness measurements in the as-cast condition and after soaking in liquid nitrogen suggest an increase in the martensite start temperature as the Si content was increased. It is concluded that Si’s effect on increasing the size and volume fraction of eutectic carbides and increasing the matrix hardness should lead to improved wear resistance over regular high-chromium white cast irons.

  19. Highly precise and compact ultrahigh vacuum rotary feedthrough

    NASA Astrophysics Data System (ADS)

    Aiura, Y.; Kitano, K.

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  20. Flight Test Performance of a High Precision Navigation Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Pierrottet, Diego; Amzajerdian, Farzin; Petway, Larry; Barnes, Bruce; Lockard, George

    2009-01-01

    A navigation Doppler Lidar (DL) was developed at NASA Langley Research Center (LaRC) for high precision velocity measurements from a lunar or planetary landing vehicle in support of the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project. A unique feature of this DL is that it has the capability to provide a precision velocity vector which can be easily separated into horizontal and vertical velocity components and high accuracy line of sight (LOS) range measurements. This dual mode of operation can provide useful information, such as vehicle orientation relative to the direction of travel, and vehicle attitude relative to the sensor footprint on the ground. System performance was evaluated in a series of helicopter flight tests over the California desert. This paper provides a description of the DL system and presents results obtained from these flight tests.

  1. High-precision buffer circuit for suppression of regenerative oscillation

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Hare, David A.; Tcheng, Ping

    1995-01-01

    Precision analog signal conditioning electronics have been developed for wind tunnel model attitude inertial sensors. This application requires low-noise, stable, microvolt-level DC performance and a high-precision buffered output. Capacitive loading of the operational amplifier output stages due to the wind tunnel analog signal distribution facilities caused regenerative oscillation and consequent rectification bias errors. Oscillation suppression techniques commonly used in audio applications were inadequate to maintain the performance requirements for the measurement of attitude for wind tunnel models. Feedback control theory is applied to develop a suppression technique based on a known compensation (snubber) circuit, which provides superior oscillation suppression with high output isolation and preserves the low-noise low-offset performance of the signal conditioning electronics. A practical design technique is developed to select the parameters for the compensation circuit to suppress regenerative oscillation occurring when typical shielded cable loads are driven.

  2. High Precision Measurement of the ^19Ne Lifetime

    NASA Astrophysics Data System (ADS)

    Broussard, Leah; Back, H. O.; Boswell, M. S.; Crowell, A. S.; Howell, C. R.; Kidd, M. F.; Pattie, R. W., Jr.; Young, A. R.; Dendooven, P. G.; Giri, G. S.; van der Hoek, D. J.; Jungmann, K.; Kruithof, W. L.; Onderwater, C. J. G.; Santra, B.; Shidling, P. D.; Sohani, M.; Versolota, O. O.; Willmann, L.; Wilschut, H. W.

    2009-10-01

    Recently, a rigorous review of the T=12 mirror transitions has identified several systems which can contribute to high precision tests exploring deviations from the Standard Model's description of the electroweak interaction. Arguably, one of the best candidates is the &+circ; decay of ^19Ne to ^19F. In this system, the main contribution to the uncertainty of extracted Standard Model parameters is due to the measured value of the lifetime of the decay. In March 2009, a high precision measurement of the lifetime of ^19Ne was made by a collaboration between the Triangle Universities Nuclear Laboratory (TUNL) and the Kernfysisch Versneller Instituut (KVI) at the Trapped Radioactive Isotopes: Microlaboratories for Fundamental Physics (Triμp) facility. An overview of the experiment and preliminary results will be presented.

  3. A high-precision polarimeter for small telescopes

    NASA Astrophysics Data System (ADS)

    Bailey, Jeremy; Cotton, Daniel V.; Kedziora-Chudczer, Lucyna

    2017-02-01

    We describe Mini-HIPPI (Miniature HIgh Precision Polarimetric Instrument), a stellar polarimeter weighing just 650 gm but capable of measuring linear polarization to ∼10-5. Mini-HIPPI is based on the use of a Ferroelectric Liquid Crystal modulator. It can easily be mounted on a small telescope and allows us to study the polarization of bright stars at levels of precision which are hitherto largely unexplored. We present results obtained with Mini-HIPPI on a 35-cm telescope. Measurements of polarized standard stars are in good agreement with predicted values. Measurements of a number of bright stars agree well with those from other high-sensitivity polarimeters. Observations of the binary system Spica show polarization variability around the orbital cycle.

  4. High-precision Velocimetry Reveals δ Cephei's Secret Companion

    NASA Astrophysics Data System (ADS)

    Anderson, Richard I.; Sahlmann, Johannes; Holl, Berry; Eyer, Laurent

    2015-08-01

    The search for extra-solar planets has driven tremendous improvements in the precision of radial velocities measured with high-resolution echelle spectrographs. However, relatively few studies have as of yet exploited the present-day extreme (m/s) instrumental precision to study Cepheid variable stars.We have been observing the prototype of classical Cepheids, δ Cephei, since September 2011 using the HERMES spectrograph mounted to the Mercator telescope located at the Roque de los Muchachos Observatory on the island of La Palma. Being one of the most-studied variable stars, we originally chose δ Cephei as a maximum-precision reference for other Cepheids in our sample. To our great surprise however, we discovered a clear orbital signature in the homogeneous HERMES data. Adding in radial velocity data from the literature, we then determined δ Cephei's orbit (cf. Anderson et al. 2015, arXiv:1503.04116). The high orbital eccentricity (e=0.647) leads to close pericenter passages (rmin ~ 9.5 RδCep) which suggest an intriguing past that requires further study, since Cepheids are well-known magnifying glasses for stellar evolution (Kippenhahn & Weigert 1994). We furthermore determined a new parallax to δ Cephei (using Hipparcos data) that is in tension with previous estimates and shows that the orbit will have to be accounted for when measuring δ Cephei's parallax with Gaia.While some of our HERMES data are as precise as 9 m/s, we found correlated excess residuals when removing the reference pulsation model and orbital motion from the HERMES radial velocity data, leaving an RMS of 47 m/s. These higher-than-expected residuals are reminiscent of the "period-jitter" or "flickering" observed in high-precision photometry of Cepheids obtained with the Kepler and MOST satellites. This reveals a fortuitous synergy between variable stars studies and the field of exoplanet research and opens the window for a better understanding of Cepheid pulsations via high-precision

  5. Dipole model analysis of high precision HERA data

    NASA Astrophysics Data System (ADS)

    Luszczak, A.; Kowalski, H.

    2014-04-01

    We analyze, within a dipole model, the inclusive deep inelastic scattering cross section data, obtained from the combination of the measurements of the H1 and ZEUS experiments performed at the HERA collider. We show that these high precision data are very well described within the dipole model framework, which is complemented with valence quark structure functions. We discuss the properties of the gluon density obtained in this way.

  6. High precision tide spectroscopy. [using the superconducting gravimeter

    NASA Technical Reports Server (NTRS)

    Goodkind, J. M.

    1978-01-01

    Diurnal and long period earth tides were measured to high accuracy and precision with the superconducting gravimeter. The results provide new evidence on the geophysical questions which have been attacked through earth tide measurements in the past. In addition, they raise new questions of potential interest. Slow fluctuations in gravity of order 10 micron gal over periods of 3 to 5 months were observed and are discussed.

  7. High-Precision Direct Method for the Radiative Transfer Problems

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Hou, Su-Qing; Yang, Ping; Wu, Kai-Su

    2013-06-01

    It is the main aim of this paper to investigate the numerical methods of the radiative transfer equation. Using the five-point formula to approximate the differential part and the Simpson formula to substitute for integral part respectively, a new high-precision numerical scheme, which has 4-order local truncation error, is obtained. Subsequently, a numerical example for radiative transfer equation is carried out, and the calculation results show that the new numerical scheme is more accurate.

  8. High-Precision Computation: Mathematical Physics and Dynamics

    SciTech Connect

    Bailey, D. H.; Barrio, R.; Borwein, J. M.

    2010-04-01

    At the present time, IEEE 64-bit oating-point arithmetic is suficiently accurate for most scientic applications. However, for a rapidly growing body of important scientic computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion e ort. This pa- per presents a survey of recent applications of these techniques and provides someanalysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, studies of the one structure constant, scattering amplitudes of quarks, glu- ons and bosons, nonlinear oscillator theory, experimental mathematics, evaluation of orthogonal polynomials, numerical integration of ODEs, computation of periodic orbits, studies of the splitting of separatrices, detection of strange nonchaotic at- tractors, Ising theory, quantum held theory, and discrete dynamical systems. We conclude that high-precision arithmetic facilities are now an indispensable compo- nent of a modern large-scale scientic computing environment.

  9. Photonic systems for high precision radial velocity measurements

    NASA Astrophysics Data System (ADS)

    Halverson, Samuel P.

    The discovery of Earth-like exoplanets has profound implications for our understanding of the origins and diversity of life in our universe. As such, developing new and improved Doppler radial velocity (RV) spectrometers capable of discovering and characterizing these planets is a high priority in the astronomical community. However, detection of true Earth-analogs remains beyond the technical reach of current Doppler RV instruments. This thesis discusses a number of technological developments designed specifically to overcome classical instrumental limitations of high precision Doppler RV measurements. These technologies are essential components of next generation instruments that aim to achieve the RV precision necessary to detect low-mass planets. This instrumentation research is driven by the development of the Habitable-zone Planet Finder (HPF), a near-infrared (NIR) Doppler spectrograph currently under development at Penn State that will detect terrestrial-mass planets orbiting nearby M-dwarfs. Furthermore, many technologies discussed will also be applied to the NASA-NSF Extreme Precision Doppler Spectrometer concept NEID, a Doppler RV instrument for the 3.5 meter WIYN telescope, slated for delivery in 2019. NEID is an ultra-stable, high resolution optical spectrometer also under development at Penn State. This thesis describes new specialized optical fiber delivery systems, designed to significantly improve instrument illumination stability, modal noise suppression systems, which suppress mode interference in optical fibers and allow spectrometers to fully realize the exquisite precision of modern wavelength calibration sources, and new photonic calibration sources, which show significant promise as potential Doppler wavelength references. These technologies represent important steps in enabling next generation instruments to reach precisions sufficient to detect terrestrial-mass planets orbiting in the Habitable-zones of nearby stars. Improving measurement

  10. Chromium in metabolic and cardiovascular disease.

    PubMed

    Hummel, M; Standl, E; Schnell, O

    2007-10-01

    Chromium is an essential mineral that appears to have a beneficial role in the regulation of insulin action, metabolic syndrome, and cardiovascular disease. There is growing evidence that chromium may facilitate insulin signaling and chromium supplementation therefore may improve systemic insulin sensitivity. Tissue chromium levels of subjects with diabetes are lower than those of normal control subjects, and a correlation exists between low circulating levels of chromium and the incidence of type 2 diabetes. Controversy still exists as to the need for chromium supplementation. However, supplementation with chromium picolinate, a stable and highly bioavailable form of chromium, has been shown to reduce insulin resistance and to help reduce the risk of cardiovascular disease and type 2 diabetes. Since chromium supplementation is a safe treatment, further research is necessary to resolve the confounding data. The existing data suggest to concentrate future studies on certain forms as chromium picolinate and doses as at least 200 mcg per day.

  11. High precision capacitive beam phase probe for KHIMA project

    NASA Astrophysics Data System (ADS)

    Hwang, Ji-Gwang; Yang, Tae-Keun; Forck, Peter

    2016-11-01

    In the medium energy beam transport (MEBT) line of KHIMA project, a high precision beam phase probe monitor is required for a precise tuning of RF phase and amplitude of Radio Frequency Quadrupole (RFQ) accelerator and IH-DTL linac. It is also used for measuring a kinetic energy of ion beam by time-of-flight (TOF) method using two phase probes. The capacitive beam phase probe has been developed. The electromagnetic design of the high precision phase probe was performed to satisfy the phase resolution of 1° (@200 MHz). It was confirmed by the test result using a wire test bench. The measured phase accuracy of the fabricated phase probe is 1.19 ps. The pre-amplifier electronics with the 0.125 ∼ 1.61 GHz broad-band was designed and fabricated for amplifying the signal strength. The results of RF frequency and beam energy measurement using a proton beam from the cyclotron in KIRAMS is presented.

  12. Automated high precision secondary pH measurements

    NASA Astrophysics Data System (ADS)

    Bastkowski, F.; Jakobsen, P. T.; Stefan, F.; Kristensen, H. B.; Jensen, H. D.; Kawiecki, R.; Wied, C. E.; Kauert, A.; Seidl, B.; Spitzer, P.; Eberhardt, R.; Adel, B.

    2013-04-01

    A new setup for high precision, automated secondary pH measurements together with a reference measurement procedure has been developed and tested in interlaboratory comparisons using buffers pH 4.005, pH 7.000, and pH 10.012 at 25 °C and 37 °C. Using primary buffers as standards, a standard uncertainty in pH better than 0.005 can be reached. The central measuring device is a one piece, thermostatted cell of PFA (perfluoroalkoxy) with a built-in Hamilton® Single Pore™ Glass electrode. Due to its flow-through principle this device allows pH measurements with low consumption of measurement solutions. The very hydrophobic and smooth PFA as construction material facilitates complete emptying of the cell. Furthermore, the tempering unit affords very precise temperature control and hence contributes to the low target uncertainty of the produced secondary buffer solutions. Use of a symmetric measurement sequence and the two point calibration was sufficient to reach high precision and accuracy.

  13. PHASES High-Precision Differential Astrometry of δ Equulei

    NASA Astrophysics Data System (ADS)

    Muterspaugh, Matthew W.; Lane, Benjamin F.; Konacki, Maciej; Burke, Bernard F.; Colavita, M. M.; Kulkarni, S. R.; Shao, M.

    2005-12-01

    Delta Equulei is among the most well-studied nearby binary star systems. Results of its observation have been applied to a wide range of fundamental studies of binary systems and stellar astrophysics. It is widely used to calibrate and constrain theoretical models of the physics of stars. We report 27 high-precision differential astrometry measurements of δ Equ from the Palomar High-precision Astrometric Search for Exoplanet Systems (PHASES). The median size of the minor axes of the uncertainty ellipses for these measurements is 26 μas. These data are combined with previously published radial velocity data and other previously published differential astrometry measurements using other techniques to produce a combined model for the system orbit. The distance to the system is determined to within one twentieth of a parsec, and the component masses are determined at the level of a percent. The constraints on masses and distance are limited by the precisions of the radial velocity data; we outline plans to improve this deficiency and discuss the outlook for further study of this binary.

  14. Modular Gravitational Reference Sensor for High Precision Astronomical Space Missions

    NASA Astrophysics Data System (ADS)

    Sun, Ke-Xun; Allen, G.; Buchman, S.; Byer, R. L.; Conklin, J. W.; DeBra, D. B.; Gill, D.; Goh, A.; Higuchi, S.; Lu, P.; Robertson, N.; Swank, A.

    2006-12-01

    We review the progress in developing the Modular Gravitational Reference Sensor (modular GRS) [1], which was first proposed as a simplified core sensor for space gravitational wave detection missions. In a modular GRS, laser beam from the remote the sensor does not illuminate the proof mass directly. The internal measurement from housing to proof mass is separated from the external interferometry. A double side grating may further simplify the structure and may better preserve the measurement precision. We review the recent progress in developing modular GRS at Stanford. We have further studied optical sensing design that combines advantage of high precision interferometric measurement and robust optical shadow sensing scheme. We have made critical progress in optical measurement of the center of mass position of a spherical proof mass at a precision without costing the dynamic range while spinning. We have successfully demonstrated the feasibility of fabricating localized grating pattern onto the dielectric and gold materials. We have conducted an initial experiment of rf heterodyne of cavity reflection and thus lowered optical power than that in the direct detection. We have further studied UV LED that will be used for AC charge management experiment. The modular GRS will be an in-time, cost effective product for the advanced Laser Interferometric Space Antenna (LISA) and the Big Bang Observatory (BBO). [1] K. Sun, G. Allen, S. Buchman, D. DeBra, and R. L. Byer, “Advanced Architecture for High Precision Space Laser Interferometers”, 5th International LISA Symposium, ESTEC, Noordwijk, The Netherlands, 12-16 July 2004. Class. Quantum Grav. 22 (2005) S287-S296.

  15. High-precision photometry for K2 Campaign 1

    NASA Astrophysics Data System (ADS)

    Huang, C. X.; Penev, K.; Hartman, J. D.; Bakos, G. Á.; Bhatti, W.; Domsa, I.; de Val-Borro, M.

    2015-12-01

    The two reaction wheel K2 mission promises and has delivered new discoveries in the stellar and exoplanet fields. However, due to the loss of accurate pointing, it also brings new challenges for the data reduction processes. In this paper, we describe a new reduction pipeline for extracting high-precision photometry from the K2 data set, and present public light curves for the K2 Campaign 1 target pixel data set. Key to our reduction is the derivation of global astrometric solutions from the target stamps, from which accurate centroids are passed on for high-precision photometry extraction. We extract target light curves for sources from a combined UCAC4 and EPIC catalogue - this includes not only primary targets of the K2 campaign 1, but also any other stars that happen to fall on the pixel stamps. We provide the raw light curves, and the products of various detrending processes aimed at removing different types of systematics. Our astrometric solutions achieve a median residual of ˜0.127 arcsec. For bright stars, our best 6.5 h precision for raw light curves is ˜20 parts per million (ppm). For our detrended light curves, the best 6.5 h precision achieved is ˜15 ppm. We show that our detrended light curves have fewer systematic effects (or trends, or red-noise) than light curves produced by other groups from the same observations. Example light curves of transiting planets and a Cepheid variable candidate, are also presented. We make all light curves public, including the raw and detrended photometry, at http://k2.hatsurveys.org.

  16. Strategies for high-precision Global Positioning System orbit determination

    NASA Technical Reports Server (NTRS)

    Lichten, Stephen M.; Border, James S.

    1987-01-01

    Various strategies for the high-precision orbit determination of the GPS satellites are explored using data from the 1985 GPS field test. Several refinements to the orbit determination strategies were found to be crucial for achieving high levels of repeatability and accuracy. These include the fine tuning of the GPS solar radiation coefficients and the ground station zenith tropospheric delays. Multiday arcs of 3-6 days provided better orbits and baselines than the 8-hr arcs from single-day passes. Highest-quality orbits and baselines were obtained with combined carrier phase and pseudorange solutions.

  17. High Precision 2-D Grating Groove Density Measurement

    NASA Astrophysics Data System (ADS)

    Zhang, Ningxiao; McEntaffer, Randall; Tedesco, Ross

    2017-08-01

    Our research group at Penn State University is working on producing X-ray reflection gratings with high spectral resolving power and high diffraction efficiency. To estimate our fabrication accuracy, we apply a precise 2-D grating groove density measurement to plot groove density distributions of gratings on 6-inch wafers. In addition to plotting a fixed groove density distribution, this method is also sensitive to measuring the variation of the groove density simultaneously. This system can reach a measuring accuracy (ΔN/N) of 10-3. Here we present this groove density measurement and some applications.

  18. Photocatalytic removal of hexavalent chromium by newly designed and highly reductive TiO2 nanocrystals.

    PubMed

    Chen, Gongde; Feng, Ji; Wang, Wenshou; Yin, Yadong; Liu, Haizhou

    2017-01-01

    Hexavalent chromium Cr(VI), a highly toxic oxyanion, widely occurs in drinking water supplies. This study designed and synthesized a new type of highly reductive TiO2 nanocrystals for photochemical Cr(VI) removal, via the thermal hydrolysis of TiCl4 in the presence of diethylene glycol (DEG). Surface analyses and hydroxyl radical measurements suggested that DEG was chemically bonded on TiO2 surface that resulted in an internal hole-scavenging effect and a high electron-releasing capacity, making it advantageous to conventional TiO2 materials. Upon UV irradiation, the synthesized TiO2 photocatalyst exhibited fast Cr(VI) reduction kinetics in diverse water chemical conditions. Fast elimination of Cr(VI) was achieved on a time scale of seconds in drinking water matrices. The removal of Cr(VI) by reductive TiO2 exhibited a three-stage kinetic behavior: an initial fast-reaction phase, a lag phase resulting from surface precipitation of Cr(OH)3(s), and a final reaction phase due to surface regeneration from oxidation-reduction induced ripening process. The lag phase disappeared in acidic conditions that prevented the formation of Cr(OH)3(s). The catalyst exhibited extremely high electron-releasing capacity that can be reused for multiple cycles of Cr(VI) removal in drinking water treatment.

  19. Key techniques of the high precision gravity field system

    NASA Astrophysics Data System (ADS)

    Xu, Weimin; Chen, Shi; Lu, Hongyan; Shi, Lei

    2017-04-01

    Ground-based gravity time series provide a direct method to monitor all sources of mass changes from local to global scale. But the effectively infinite spatial sensitivity of gravity measurements make it difficult to isolate the signal of interest. The high precision gravity field system is an alternative approach of modeling mass changes under-ground. The field system, consists of absolute gravity, gravity and gravity gradient, GNSS, leveling and climate hydrology measurements, can improve the signal-to-noise ratio for many applications by removing contributions of unwanted signal from elevation changes, air pressure changes, local hydrology, and others. The networks of field system combination, such as field-profile in more than 100 kilometers, can be used in critical zone with high seismic risk for monitoring earth dynamics, volcanic and seismic phenomena. The system is constituted by 9 typical observation stations in 3*3 array (or 4 in 2*2 array) in 60 square meters field, each station is designed for integrated measurements, including absolute gravity, gravity gradient, elevation changes, air pressure and hydrology. Time-lapse gravity changes resulting from absolute gravimeter (FG5 or A10) with standard deviation less than 2 μGal, without the contributions of Earth tides, loading and polar motion. Additional measurements such as air pressure change, local hydrology and soil moisture are indispensable. The elevation changes resulting from GNSS (on the base station) and leveling (between stations) with precision less than 10 mm. The gravity gradient is the significant measurement for delimiting the location of the related mass changes underground the station, which is measured by Scintrex CG-5 gravimeters in different height (80cm in the test field), with precision less than 10 E. It is necessary to improve the precision of gravity gradient measurements by certain method in field experiment for the high precision measurement system. Acknowledgment: This

  20. Thermal design and flight validation for high precision camera

    NASA Astrophysics Data System (ADS)

    Meng, Henghui; Sun, Lixia; Zhang, Chuanqiang; Geng, Liyin

    2015-10-01

    High precision camera, designed for advanced optical system, with a wide field of vision, high resolution and fast response, has a wild range of applications. As the main payload for spacecraft, the optical remote sensor is mounted exposed to the space, which means it should have a reliable optical performance in harsh space environment during lifetime. Because of the special optical characteristic, imaging path should be accurate, and less thermal deformation for the optical parts is required in the working process, so the high precision camera has a high level requirement for temperature. High resolution space camera is generally required to own the capability of adapting to space thermal environments. The flexible satellite's change of rolling attitude affects the temperature distribution of the camera and makes a difference to optical performance. The thermal control design of space camera is presented, and analysis the temperature data in orbit to prove the thermal design correct. It is proved that the rolling attitude has more influence on outer parts and less influence on inner parts, and active thermal control can weaken the influence of rolling attitude.

  1. Fabrication of Unique Magnetic Bionanocomposite for Highly Efficient Removal of Hexavalent Chromium from Water

    NASA Astrophysics Data System (ADS)

    Zhong, Yunlei; Qiu, Xun; Chen, Dongyun; Li, Najun; Xu, Qingfeng; Li, Hua; He, Jinghui; Lu, Jianmei

    2016-08-01

    Biotreatment of hexavalent chromium has attracted widespread interest due to its cost effective and environmental friendliness. However, the difficult separation of biomass from aqueous solution and the slow hexavalent chromium bioreduction rate are bottlenecks for biotechnology application. In this approach, a core-shell structured functional polymer coated magnetic nanocomposite was prepared for enriching the hexavalent chromium. Then the nanocomposite was connected to the bacteria via amines on bacterial (Bacillus subtilis ATCC-6633) surface. Under optimal conditions, a series of experiments were launched to degrade hexavalent chromium from the aqueous solution using the as-prepared bionanocomposite. Results showed that B. subtilis@Fe3O4@mSiO2@MANHE (BFSM) can degrade hexavalent chromium from the water more effectively (a respectable degradation efficiency of about 94%) when compared with pristine B. subtilis and Fe3O4@mSiO2@MANHE (FSM). Moreover, the BFSM could be separated from the wastewater by magnetic separation technology conveniently due to the Fe3O4 core of FSM. These results indicate that the application of BFSM is a promising strategy for effective treating wastewater containing hexavalent chromium.

  2. High concentrations of chromium in lung tissue from lung cancer patients

    SciTech Connect

    Anttila, S.; Kokkonen, P.; Paeaekkoe PRai; Rainio, P.; Kalliomaeki, P.L.P.; Pallon, J.; Malmqvist, K.; Pakarinen, P.; Naentoe, V.Su.; Sutinen, S.

    1989-02-01

    The pulmonary chromium content was determined by plasma atomic emission spectrometer (DCP-AES) from 53 lung cancer and 43 control patients, and compared with smoking habits, severity of emphysema and occupational history. The chromium content from the lung cancer patients was higher than that from the smoking (P less than 0.025) or nonsmoking control patients (6.4 +/- 4.3, 4.0 +/- 4.0, and 2.2 +/- 0.6 microgram/g dry weight, respectively). A positive correlation between the pulmonary chromium and smoking time (P less than 0.025) and the severity of emphysema (P less than 0.001) was found in the control but not in the cancer patients. The difference in the pulmonary chromium content was greatest between those lung cancer and control patients who were light smokers or had mild emphysema. This group of lung cancer patients included subjects with occupational exposure to chromium. The possibility of occupational cancer should be considered especially with light smokers. The grade of emphysema and metals such as chromium accumulating from tobacco could serve as objective indicators of smoking.

  3. Fabrication of Unique Magnetic Bionanocomposite for Highly Efficient Removal of Hexavalent Chromium from Water

    PubMed Central

    Zhong, Yunlei; Qiu, Xun; Chen, Dongyun; Li, Najun; Xu, Qingfeng; Li, Hua; He, Jinghui; Lu, Jianmei

    2016-01-01

    Biotreatment of hexavalent chromium has attracted widespread interest due to its cost effective and environmental friendliness. However, the difficult separation of biomass from aqueous solution and the slow hexavalent chromium bioreduction rate are bottlenecks for biotechnology application. In this approach, a core-shell structured functional polymer coated magnetic nanocomposite was prepared for enriching the hexavalent chromium. Then the nanocomposite was connected to the bacteria via amines on bacterial (Bacillus subtilis ATCC-6633) surface. Under optimal conditions, a series of experiments were launched to degrade hexavalent chromium from the aqueous solution using the as-prepared bionanocomposite. Results showed that B. subtilis@Fe3O4@mSiO2@MANHE (BFSM) can degrade hexavalent chromium from the water more effectively (a respectable degradation efficiency of about 94%) when compared with pristine B. subtilis and Fe3O4@mSiO2@MANHE (FSM). Moreover, the BFSM could be separated from the wastewater by magnetic separation technology conveniently due to the Fe3O4 core of FSM. These results indicate that the application of BFSM is a promising strategy for effective treating wastewater containing hexavalent chromium. PMID:27502074

  4. High Precision U/Th Dating of First Polynesian Settlement

    PubMed Central

    Burley, David; Weisler, Marshall I.; Zhao, Jian-xin

    2012-01-01

    Previous studies document Nukuleka in the Kingdom of Tonga as a founder colony for first settlement of Polynesia by Lapita peoples. A limited number of radiocarbon dates are one line of evidence supporting this claim, but they cannot precisely establish when this event occurred, nor can they afford a detailed chronology for sequent occupation. High precision U/Th dates of Acropora coral files (abraders) from Nukuleka give unprecedented resolution, identifying the founder event by 2838±8 BP and documenting site development over the ensuing 250 years. The potential for dating error due to post depositional diagenetic alteration of ancient corals at Nukuleka also is addressed through sample preparation protocols and paired dates on spatially separated samples for individual specimens. Acropora coral files are widely distributed in Lapita sites across Oceania. U/Th dating of these artifacts provides unparalleled opportunities for greater precision and insight into the speed and timing of this final chapter in human settlement of the globe. PMID:23144962

  5. A high-performance flow-field structured iron-chromium redox flow battery

    NASA Astrophysics Data System (ADS)

    Zeng, Y. K.; Zhou, X. L.; An, L.; Wei, L.; Zhao, T. S.

    2016-08-01

    Unlike conventional iron-chromium redox flow batteries (ICRFBs) with a flow-through cell structure, in this work a high-performance ICRFB featuring a flow-field cell structure is developed. It is found that the present flow-field structured ICRFB reaches an energy efficiency of 76.3% with a current density of 120 mA cm-2 at 25 °C. The energy efficiency can be as high as 79.6% with an elevated current density of 200 mA cm-2 at 65 °C, a record performance of the ICRFB in the existing literature. In addition, it is demonstrated that the energy efficiency of the battery is stable during the cycle test, and that the capacity decay rate of the battery is 0.6% per cycle. More excitingly, the high performance of the flow-field structured battery significantly lowers the capital cost at 137.6 kWh-1, which is 28.2% lower than that of the conventional ICRFB for 8-h energy storage.

  6. The carcinogenicity of chromium

    PubMed Central

    Norseth, Tor

    1981-01-01

    The carcinogenicity of chromium compounds is reviewed with specific attention to the gaps in knowledge for risk estimation and research needs. The most important problems at present are whether trivalent chromium compounds cause cancer, and whether there is a difference in cancer causing effects between the soluble and the slightly soluble hexavalent compounds in the practical exposure situation. Dose estimates for risk estimation based on epidemiological investigations are also lacking. Present evidence indicates that the trivalent chromium compounds do not cause cancer although high concentrations in some in vitro systems have shown genetic toxicity. Hexavalent chromium compounds cause cancer in humans, in experimental animals and exert genetic toxicity in bacteria and in mammalian cells in vitro. Epidemiological evidence and animal experiments indicate that the slightly soluble hexavalent salts are the most potent carcinogens, but proper identification and characterization of exposure patterns in epidemiological work are lacking. Workers also tend to have mixed exposures. Soluble and slightly soluble salts are equally potent genotoxic agents in vitro. Further work for establishing dose estimates for risk evaluation in epidemiological work is important. In vitro systems should be applied for further identification of the mechanism of the carcinogenic effects, and animal experiments are urgent for comparison of the carcinogenic potency of the different hexavalent salts. Hexavalent chromium salts must be regarded as established carcinogens, and proper action should be taken in all industries with regard to such exposure. At present the carcinogenic risk to the general population caused by chromium compounds seems to be negligible, chromium in cigarettes, however, is an uncertainty in this respect. The amount of chromium and the type of chromium compounds inhaled from cigarettes is not known. PMID:7023928

  7. High-precision ground-based photometry of exoplanets

    NASA Astrophysics Data System (ADS)

    de Mooij, Ernst J. W.; Jayawardhana, Ray

    2013-04-01

    High-precision photometry of transiting exoplanet systems has contributed significantly to our understanding of the properties of their atmospheres. The best targets are the bright exoplanet systems, for which the high number of photons allow very high signal-to-noise ratios. Most of the current instruments are not optimised for these high-precision measurements, either they have a large read-out overhead to reduce the readnoise and/or their field-of-view is limited, preventing simultaneous observations of both the target and a reference star. Recently we have proposed a new wide-field imager for the Observatoir de Mont-Megantic optimised for these bright systems (PI: Jayawardhana). The instruments has a dual beam design and a field-of-view of 17' by 17'. The cameras have a read-out time of 2 seconds, significantly reducing read-out overheads. Over the past years we have obtained significant experience with how to reach the high precision required for the characterisation of exoplanet atmospheres. Based on our experience we provide the following advice: Get the best calibrations possible. In the case of bad weather, characterise the instrument (e.g. non-linearity, dome flats, bias level), this is vital for better understanding of the science data. Observe the target for as long as possible, the out-of-transit baseline is as important as the transit/eclipse itself. A short baseline can lead to improperly corrected systematic and mis-estimation of the red-noise. Keep everything (e.g. position on detector, exposure time) as stable as possible. Take care that the defocus is not too strong. For a large defocus, the contribution of the total flux from the sky-background in the aperture could well exceed that of the target, resulting in very strict requirements on the precision at which the background is measured.

  8. Describing oscillations of high energy neutrinos in matter precisely.

    PubMed

    Akhmedov, E K H; Maltoni, M; Smirnov, A Y U

    2005-11-18

    We present a formalism for precise description of oscillation phenomena in matter at high energies or high densities, V > Delta m(2)/2E, where V is the matter-induced potential of neutrinos. The accuracy of the approximation is determined by the quantity, where is the mixing angle in matter and is a typical change of the potential over the oscillation length (). We derive simple and physically transparent formulas for the oscillation probabilities, which are valid for arbitrary matter density profiles. They can be applied to oscillations of high-energy accelerator, atmospheric, and cosmic neutrinos in the matter of the Earth, substantially simplifying numerical calculations and providing an insight into the physics of neutrino oscillations in matter. The effect of parametric enhancement of the oscillations of high-energy neutrinos is considered.

  9. Precise measurement of magnetization characteristics in high pulsed field

    NASA Astrophysics Data System (ADS)

    Nakahata, Y.; Borkowski, B.; Shimoji, H.; Yamada, K.; Todaka, T.; Enokizono, M.

    2012-04-01

    Permanent magnets, especially Nd-Fe-B magnets, are very important engineering elements that are widely used in many applications. The detailed design of electrical and electronic equipment using permanent magnets requires the precise measurement of magnetization characteristics. High pulsed magnetic fields can be used to measure the magnetization characteristics of permanent magnets in the easy and hard magnetization directions. Errors influencing the measurements stem from the relationship between the tested material, pick-up sensor configuration, and excitation coil. We present an analysis of the effect of the sensor construction on the accuracy of the measurements of the material's magnetic properties. We investigated the coaxial and series types sensor configurations.

  10. High-precision measurements of global stellar magnetic fields

    NASA Astrophysics Data System (ADS)

    Plachinda, S. I.

    2014-06-01

    This paper presents a brief history of the development of devices and techniques for high-precision measurements of stellar magnetic fields. Two main approaches for the processing of spectral-polarimetric observations are described: the method of least-squares deconvolution (LSD), which is used to find a mean-weighted average of the normalized polarization profile using a set of spectral lines, and a method in which each individual spectral line is used to determine the magnetic field, viz., the single line method (SL). The advantages and disadvantages of the LSD and SL methods are discussed.

  11. High precision photon flux determination for photon tagging experiments

    SciTech Connect

    Teymurazyan, A.; Ahmidouch, A.; Ambrozewicz, P.; Asratyan, A.; Baker, K.; Benton, L.; Burkert, V.; Clinton, E.; Cole, P.; Collins, P.; Dale, D.; Danagoulian, S.; Davidenko, G.; Demirchyan, R.; Deur, A.; Dolgolenko, A.; Dzyubenko, G.; Ent, R.; Evdokimov, A.; Feng, J.; Gabrielyan, M.; Gan, L.; Gasparian, A.; Glamazdin, A.; Goryachev, V.; Hardy, K.; He, J.; Ito, M.; Jiang, L.; Kashy, D.; Khandaker, M.; Kolarkar, A.; Konchatnyi, M.; Korchin, A.; Korsch, W.; Kosinov, O.; Kowalski, S.; Kubantsev, M.; Kubarovsky, V.; Larin, I.; Lawrence, D.; Li, X.; Martel, P.; Matveev, V.; McNulty, D.; Mecking, B.; Milbrath, B.; Minehart, R.; Miskimen, R.; Mochalov, V.; Nakagawa, I.; Overby, S.; Pasyuk, E.; Payen, M.; Pedroni, R.; Prok, Y.; Ritchie, B.; Salgado, C.; Shahinyan, A.; Sitnikov, A.; Sober, D.; Stepanyan, S.; Stevens, W.; Underwood, J.; Vasiliev, A.; Vishnyakov, V.; Wood, M.; Zhou, S.

    2014-12-01

    The Jefferson Laboratory PrimEx Collaboration has developed and implemented a method to control the tagged photon flux in photoproduction experiments at the 1% level over the photon energy range from 4.9 to 5.5 GeV. This method has been successfully implemented in a high precision measurement of the neutral pion lifetime. Here, we outline the experimental equipment and the analysis techniques used to accomplish this. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and a new method for post-bremsstrahlung electron counting.

  12. Multidimensional Image Analysis for High Precision Radiation Therapy.

    PubMed

    Arimura, Hidetaka; Soufi, Mazen; Haekal, Mohammad

    2017-01-01

    High precision radiation therapy (HPRT) has been improved by utilizing conventional image engineering technologies. However, different frameworks are necessary for further improvement of HPRT. This review paper attempted to define the multidimensional image and what multidimensional image analysis is, which may be feasible for increasing the accuracy of HPRT. A number of researches in radiation therapy field have been introduced to understand the multidimensional image analysis. Multidimensional image analysis could greatly assist clinical staffs in radiation therapy planning, treatment, and prediction of treatment outcomes.

  13. Future high precision experiments and new physics beyond Standard Model

    SciTech Connect

    Luo, Mingxing

    1993-04-01

    High precision (< 1%) electroweak experiments that have been done or are likely to be done in this decade are examined on the basis of Standard Model (SM) predictions of fourteen weak neutral current observables and fifteen W and Z properties to the one-loop level, the implications of the corresponding experimental measurements to various types of possible new physics that enter at the tree or loop level were investigated. Certain experiments appear to have special promise as probes of the new physics considered here.

  14. Future high precision experiments and new physics beyond Standard Model

    SciTech Connect

    Luo, Mingxing.

    1993-01-01

    High precision (< 1%) electroweak experiments that have been done or are likely to be done in this decade are examined on the basis of Standard Model (SM) predictions of fourteen weak neutral current observables and fifteen W and Z properties to the one-loop level, the implications of the corresponding experimental measurements to various types of possible new physics that enter at the tree or loop level were investigated. Certain experiments appear to have special promise as probes of the new physics considered here.

  15. High-precision HST proper motions of globular clusters

    NASA Astrophysics Data System (ADS)

    Bellini, A.

    Photometric and spectroscopic studies over the last 15 years have revolutionized our understanding of globular clusters (GCs). We now know that essentially all GCs host multiple stellar populations that can be identified along all evolutionary sequences and are characterized by differences in light elements, He, and sometimes Fe. These findings present a number of formidable challenges for the study of the formation and evolution of GCs. The internal kinematics of multiple stellar populations is a fundamental piece of the puzzle and high-precision proper motions are the key tool to shed light on many open questions regarding GCs.

  16. High-precision micro/nano-scale machining system

    DOEpatents

    Kapoor, Shiv G.; Bourne, Keith Allen; DeVor, Richard E.

    2014-08-19

    A high precision micro/nanoscale machining system. A multi-axis movement machine provides relative movement along multiple axes between a workpiece and a tool holder. A cutting tool is disposed on a flexible cantilever held by the tool holder, the tool holder being movable to provide at least two of the axes to set the angle and distance of the cutting tool relative to the workpiece. A feedback control system uses measurement of deflection of the cantilever during cutting to maintain a desired cantilever deflection and hence a desired load on the cutting tool.

  17. Ultrasound Velocity Measurements in High-Chromium Steel Under Plastic Deformation

    NASA Astrophysics Data System (ADS)

    Lunev, Aleksey; Bochkareva, Anna; Barannikova, Svetlana; Zuev, Lev

    2016-04-01

    In the present study, the variation of the propagation velocity of ultrasound in the plastic deformation of corrosion-resistant high-chromium steel 40X13 with ferrite-carbide (delivery status), martensitic (quenched) and sorbitol (after high-temperature tempering) structures have beem studied/ It is found that each state shows its view of the loading curve. In the delivery state diagram loading is substantially parabolic throughout, while in the martensitic state contains only linear strain hardening step and in the sorbitol state the plastic flow curve is three-step. The velocity of ultrasonic surface waves (Rayleigh waves) was measured simultaneously with the registration of the loading curve in the investigated steel in tension. It is shown that the dependence of the velocity of ultrasound in active loading is determined by the law of plastic flow, that is, the staging of the corresponding diagram of loading. Structural state of the investigated steel is not only changing the type of the deformation curve under uniaxial tension, but also changes the nature of ultrasound speed of deformation.

  18. Identification, size classification and evolution of Laves phase precipitates in high chromium, fully ferritic steels.

    PubMed

    Lopez Barrilao, Jennifer; Kuhn, Bernd; Wessel, Egbert

    2017-10-01

    To fulfil the new challenges of the German "Energiewende" more efficient, sustainable, flexible and cost-effective energy technologies are strongly needed. For a reduction of consumed primary resources higher efficiency steam cycles with increased operating parameters, pressure and temperature, are mandatory. Therefore advanced materials are needed. The present study focuses on a new concept of high chromium, fully ferritic steels. These steels, originally designed for solid oxide fuel cell applications, provide favourable steam oxidation resistance, creep and thermomechanical fatigue behaviour in comparison to conventional ferritic-martensitic steels. The strength of this type of steel is achieved by a combination of solid-solution hardening and precipitation strengthening by intermetallic Laves phase particles. The effect of alloy composition on particle composition was measured by energy dispersive X-ray spectroscopy and partly verified by thermodynamic modelling results. Generally the Laves phase particles demonstrated high thermodynamic stability during long-term annealing up to 40,000h at 600°C. Variations in chemical alloy composition influence Laves phase particle formation and consequently lead to significant changes in creep behaviour. For this reason particle size distribution evolution was analysed in detail and associated with the creep performance of several trial alloys. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. High-pressure structural phase transitions in chromium-doped BaFe2As2

    SciTech Connect

    Uhoya, Walter; Brill, Joseph W.; Montgomery, Jeffrey M; Samudrala, G K; Tsoi, Georgiy; Vohra, Y. K.; Weir, S. T.; Safa-Sefat, Athena

    2012-01-01

    We report on the results from high pressure x-ray powder diffraction and electrical resistance measurements for hole doped BaFe{sub 2-x}Cr{sub x}As{sub 2} (x = 0, 0.05, 0.15, 0.4, 0.61) up to 81 GPa and down to 10 K using a synchrotron source and diamond anvil cell (DAC). At ambient temperature, an isostructural phase transition from a tetragonal (T) phase (I4/mmm) to a collapsed tetragonal (CT) phase is observed at 17 GPa. This transition is found to be dependent on ambient pressure unit cell volume and is slightly shifted to higher pressure upon increase in the Cr-doping. Unlike BaFe{sub 2}As{sub 2} which superconduct under high pressure, we have not detected any evidence of pressure induced superconductivity in chromium doped samples in the pressure and temperature range of this study. The measured equation of state parameters are presented for both the tetragonal and collapsed tetragonal phases for x = 0.05, 0.15, 0.40 and 0.61.

  20. High precision wavelength meter with Fabry-Perot optics

    NASA Astrophysics Data System (ADS)

    Konishi, N.; Suzuki, T.; Taira, Y.; Kato, H.; Kasuya, T.

    1981-07-01

    A high precision wavelength meter in the visible is described, which is based on a Fabry-Perot interferometer with several etalons of different resolution. The interference fringe pattern projected on a photo-diode array detector is computationally processed to give a stepwise refinement of the wavelength value to any adjusted accuracy. The present model intends to provide digital and real-time values of high precision wavelength for dye-laser spectroscopy, and to serve as a monitor or as a pilot for wavelength control of a dye-laser source of nanosecond pulses. The model is, therefore, designed with particular emphasis on its short-pulse capability and on-line mode of operation as well as on its high sensitivity and resolution. Some arrangements of essential necessity are involved therein, such as to avoid an errorneous wavelength readout for a noisy incidence of pulsed field. The ultimate accuracy of wavelength measurement is prescribed by the resolving power of the thickest etalon employed. As applied to the pulsed source, the model determines the wavelength to the accuracy of ±one part in 107 for even a single shot nanosecond incidence of a fraction of μJ energy. The design and performance are described in connection to pulsed dye-laser incidence.

  1. A High Precision Terahertz Wave Image Reconstruction Algorithm

    PubMed Central

    Guo, Qijia; Chang, Tianying; Geng, Guoshuai; Jia, Chengyan; Cui, Hong-Liang

    2016-01-01

    With the development of terahertz (THz) technology, the applications of this spectrum have become increasingly wide-ranging, in areas such as non-destructive testing, security applications and medical scanning, in which one of the most important methods is imaging. Unlike remote sensing applications, THz imaging features sources of array elements that are almost always supposed to be spherical wave radiators, including single antennae. As such, well-developed methodologies such as Range-Doppler Algorithm (RDA) are not directly applicable in such near-range situations. The Back Projection Algorithm (BPA) can provide products of high precision at the the cost of a high computational burden, while the Range Migration Algorithm (RMA) sacrifices the quality of images for efficiency. The Phase-shift Migration Algorithm (PMA) is a good alternative, the features of which combine both of the classical algorithms mentioned above. In this research, it is used for mechanical scanning, and is extended to array imaging for the first time. In addition, the performances of PMA are studied in detail in contrast to BPA and RMA. It is demonstrated in our simulations and experiments described herein that the algorithm can reconstruct images with high precision. PMID:27455269

  2. High-precision Photogrammetric Surface Figure Measurements under Cryogenic Environment

    NASA Astrophysics Data System (ADS)

    Zheng, Lou; Yuan, Qian; Sheng-hong, Fan; Chang-ru, Liu; Hai-ren, Wang; Ying-xi, Zuo; Jin-quan, Cheng; Ji, Yang

    2017-01-01

    Limited by the working temperature of the test equipment, most of high-precision surface figure measurement techniques cannot be put into application under a cryogenic environment. This paper reports the first attempt to measure the surface figure of a high-precision terahertz reflector panel under low temperatures based on photogrammetry. The measurement employs a high-resolution industrial camera sitting on the automatic testing platform which enables photos been taken in an automatic fashion inside a climate chamber. A repeatable accuracy of 2.1 μm (rms) is achieved under the cryogenic environment. Furthermore, the surface figure measured by a three-coordinate measuring machine under the room temperature is used to calibrate the thickness differences of the targets. By this technique, the surface figure of an aluminum prototype panel of the 5 meter Dome A Terahertz Telescope (DATE5) is measured from room temperature down to -55°C to obtain the rule of variation of surface deformation of the panel under low temperatures.

  3. The importance of high-precision hadronic calorimetry to physics

    NASA Astrophysics Data System (ADS)

    Hauptman, John

    2016-11-01

    The reconstruction and high-precision measurement of the four-vectors of W and Z decays to quarks, which constitute nearly 70% of their decay branching fractions, are critical to a high efficiency and high quality experiment. Furthermore, it is crucial that the energy resolution, and consequently the resolution on the invariant mass of the two fragmenting quarks, is comparable to the energy-momentum resolution on the other particles of the standard model, in particular, electrons, photons, and muons, at energies around 100 GeV. I show that this “unification of resolutions” on all particles of the standard model is now in sight, and will lead to excellent physics at an electron-positron collider.

  4. New machining method of high precision infrared window part

    NASA Astrophysics Data System (ADS)

    Yang, Haicheng; Su, Ying; Xu, Zengqi; Guo, Rui; Li, Wenting; Zhang, Feng; Liu, Xuanmin

    2016-10-01

    Most of the spherical shell of the photoelectric multifunctional instrument was designed as multi optical channel mode to adapt to the different band of the sensor, there were mainly TV, laser and infrared channels. Without affecting the optical diameter, wind resistance and pneumatic performance of the optical system, the overall layout of the spherical shell was optimized to save space and reduce weight. Most of the shape of the optical windows were special-shaped, each optical window directly participated in the high resolution imaging of the corresponding sensor system, and the optical axis parallelism of each sensor needed to meet the accuracy requirement of 0.05mrad.Therefore precision machining of optical window parts quality will directly affect the photoelectric system's pointing accuracy and interchangeability. Processing and testing of the TV and laser window had been very mature, while because of the special nature of the material, transparent and high refractive rate, infrared window parts had the problems of imaging quality and the control of the minimum focal length and second level parallel in the processing. Based on years of practical experience, this paper was focused on how to control the shape and parallel difference precision of infrared window parts in the processing. Single pass rate was increased from 40% to more than 95%, the processing efficiency was significantly enhanced, an effective solution to the bottleneck problem in the actual processing, which effectively solve the bottlenecks in research and production.

  5. High precision measurements of the free form mirror geometries

    NASA Astrophysics Data System (ADS)

    Dontsov, Denis; Rahneberg, Ilko; Pöschel, Wolfgang; Schott, Walter

    2017-06-01

    There are many established technologies for precise characterization of the mirror geometries available. The paper presents a high precision measuring setup based on a single beam homodyne laser interferometer. The single beam interferometer is moved by a linear stage between the reference and measuring surfaces and delivers the differences between them. The reference mirror defines an absolute accuracy of the method. This point based method allows a high spatial resolution of the mirror shape and is suitable for measurements of the free form mirror geometries as long as the radius of curvature does not exceed the maximal toleranced tilt. The measuring results have been obtained for optics with dimensions of up to 50 mm and have been verified both for plan mirrors and for mirrors with radii of curvature in the range between 6 m and 10 m. A repeatability of the measuring results in sub-nanometer range can be shown. Especially for mirrors with a very big radius of curvature the knowledge of the exact position of the each measuring point on the surface is important for minimizing the errors of the mathematical fitting algorithms. Therefore a triple beam interferometer has been used for measurements of the stage position. The tight synchronization between all interferometer channels of 0.1 ns allows very fast "on-the-fly" scans of the surface.

  6. High Precision Oxygen Measurements as a Tool for CCS Monitoring

    NASA Astrophysics Data System (ADS)

    Trugman, A. T.; Dvonch, C.; Clegg, S. M.; Rahn, T.

    2011-12-01

    CO2 emissions from below ground carbon storage reservoirs can be difficult to discriminate from CO2 produced via natural plant and microbial respiration. However, because respiration produces CO2 and consumes O2 in an approximately 1:1 ratio, it is possible to characterize leakage sources by measurement of simultaneous changes of both O2 and CO2. This approach is complicated by the fact that O2 comprises approximately 21% of the atmosphere, while CO2 is only present in the background atmosphere at ~400 parts per million, making it necessary to accurately measure changes in O2 concentration to six significant figures. Here we describe a portable high precision oxygen measurement system that employs a modified commercial fuel cell analyzer to quantify small changes in O2 concentration. High precision is achieved through precise control of flow and pressure, allowing near part per million precision of O2 and CO2 concentrations. This system has been incorporated into a mobile laboratory and has been deployed to the ZERT controlled release site in Bozeman, Montana and to a natural analog CO2 leak at Soda Springs, Idaho. Samples were collected at ground level, 1 meter, and 3 meters above the CO2 source and are displayed as the ratio of the O2 difference relative to a reference to the CO2 difference in concentration relative to the same reference (ΔO2/ΔCO2). It was observed that at wind speeds ≤ 2 m/s, the ΔO2/ΔCO2 anomaly decreased with height and was still significantly different from background at 3 m. With increasing wind speed, ΔO2/ΔCO2 anomalies decreased to background levels at 1 and 3 m but remained detectable at the ground surface. We will discuss attempts to quantify the CO2 release rate utilizing the measured ΔO2/ΔCO2 elevation profiles and will present complementary eddy covariance data for comparison.

  7. Effect of Heat Treatment on the Impact Toughness of `High-Chromium Cast Iron - Low Alloy Steel' Bimetal Components

    NASA Astrophysics Data System (ADS)

    Özdemir, Z.

    2017-03-01

    A bimetallic `low-alloy steel - high-chromium cast iron' composite obtained by successive sand casting is studied and shown to have good cohesion on the interface and no casting defects. The hardness and the impact toughness of the bimetal increase simultaneously. The microstructure is more homogeneous after diffusion annealing at 1040°C, rapid cooling, and 3-h tempering at 270°C.

  8. Irradiation-induced impurity segregation and ductile-to-brittle transition temperature shift in high chromium ferritic/martensitic steels

    NASA Astrophysics Data System (ADS)

    Lu, Z.; Faulkner, R. G.; Flewitt, P. E. J.

    2007-08-01

    A model is presented to predict irradiation-induced impurity segregation and its contribution to the ductile-to-brittle transition temperature (DBTT) shift in high chromium ferritic steels. The hardening contribution (dislocation loops, voids and precipitates) is also considered in this study. The predicted results are compared with the experimental DBTT shifts data for irradiated 9Cr1MoVNb and 12Cr1MoVW steels with different grain sizes.

  9. Influence of Basicity on High-Chromium Vanadium-Titanium Magnetite Sinter Properties, Productivity, and Mineralogy

    NASA Astrophysics Data System (ADS)

    Zhou, Mi; Yang, Songtao; Jiang, Tao; Xue, Xiangxin

    2015-05-01

    The effect of basicity on high-chromium vanadium-titanium magnetite (V-Ti-Cr) sintering was studied via sintering pot tests. The sinter rate, yield, and productivity were calculated before determining sinter strength (TI) and reduction degradation index (RDI). Furthermore, the effect of basicity on V-Ti-Cr sinter mineralogy was clarified using metallographic microscopy, x-ray diffraction, and scanning electron microscopy-energy-dispersive x-ray spectroscopy. The results indicate that increasing basicity quickly increases the sintering rate from 25.4 mm min-1 to 28.9 mm min-1, yield from 75.3% to 87.2%, TI from 55.4% to 64.8%, and productivity from 1.83 t (m2 h)-1 to 1.94 t (m2 h)-1 before experiencing a slight drop. The V-Ti-Cr sinter shows complex mineral composition, with main mineral phases such as magnetite, hematite, silicate (dicalcium silicate, Ca-Fe olivine, glass), calcium and aluminum silico-ferrite (SFCA/SFCAI) and perovskite. Perovskite is notable because it lowers the V-Ti sinter strength and RDI. The well intergrowths between magnetite and SFCA/SFCAI, and the decrease in perovskite and secondary skeletal hematite are the key for improving TI and RDI. Finally, a comprehensive index was calculated, and the optimal V-Ti-Cr sinter basicity also for industrial application was 2.55.

  10. Characterization of Microstructure and Mechanical Properties of High Chromium Cast Irons Using SEM and Nanoindentation

    NASA Astrophysics Data System (ADS)

    Chen, Ling; Iyengar, Srinivasan; Zhou, Jinming; Turba, Krystof; Ståhl, Jan-Eric

    2015-01-01

    The effects of composition changes and heat treatment on the microstructure and mechanical properties of high-chromium white cast irons were studied in order to characterize possible improvements in product performance and machinability. Materials characterization was performed using nanoindentation, SEM, and EDS techniques. Present results show that changes in carbon and silicon contents as well as heat treatment strongly affect the mechanical properties and their variation in the material. In the as-cast condition, the sample with relatively lower carbon and silicon contents has an austenite-martensite matrix and is much harder than the sample with relatively higher carbon and silicon contents having more eutectic carbides in a bainite matrix. Annealing leads to softening of the materials relative to the as-cast condition, with the relatively higher carbon-silicon material being marginally harder due to the presence of more eutectic carbides. A similar trend is seen after the hardening treatment, and the presence of primary carbide can restrict the extent of hardening due to the loss of alloying elements from the matrix.

  11. Strong correlations and the search for high-Tc superconductivity in chromium pnictides and chalcogenides

    NASA Astrophysics Data System (ADS)

    Pizarro, J. M.; Calderón, M. J.; Liu, J.; Muñoz, M. C.; Bascones, E.

    2017-02-01

    Undoped iron superconductors accommodate n =6 electrons in five d orbitals. Experimental and theoretical evidence shows that the strength of correlations increases with hole doping, as the electronic filling approaches half filling with n =5 electrons. This evidence delineates a scenario in which the parent compound of iron superconductors is the half-filled system, in analogy to cuprate superconductors. In cuprates the superconductivity can be induced upon electron or hole doping. In this work we propose to search for high-Tc superconductivity and strong correlations in chromium pnictides and chalcogenides with n <5 electrons. By means of ab initio slave-spin and multiorbital random-phase-approximation calculations we analyze the strength of the correlations and the superconducting and magnetic instabilities in these systems with the main focus on LaCrAsO. We find that electron-doped LaCrAsO is a strongly correlated system with competing magnetic interactions, with (π ,π ) antiferromagnetism and nodal d -wave pairing being the most plausible magnetic and superconducting instabilities, respectively.

  12. Effect of molybdenum, vanadium, boron on mechanical properties of high chromium white cast iron in as-cast condition

    NASA Astrophysics Data System (ADS)

    Nurjaman, F.; Sumardi, S.; Shofi, A.; Aryati, M.; Suharno, B.

    2016-02-01

    In this experiment, the effect of the addition carbide forming elements on high chromium white cast iron, such as molybdenum, vanadium and boron on its mechanical properties and microstructure was investigated. The high chromium white cast iron was produced by casting process and formed in 50 mm size of grinding balls with several compositions. Characterization of these grinding balls was conducted by using some testing methods, such as: chemical and microstructure analysis, hardness, and impact test. From the results, the addition of molybdenum, vanadium, and boron on high chromium white cast iron provided a significant improvement on its hardness, but reduced its toughness. Molybdenum induced fully austenitic matrix and Mo2C formation among eutectic M7C3 carbide. Vanadium was dissolved in the matrix and carbide. While boron was played a role to form fine eutectic carbide. Grinding balls with 1.89 C-13.1 Cr-1.32 Mo-1.36 V-0.00051 B in as-cast condition had the highest hardness, which was caused by finer structure of eutectic carbide, needle like structure (upper bainite) matrix, and martensite on its carbide boundary.

  13. The development of high precision carbon fiber composite mirror

    NASA Astrophysics Data System (ADS)

    Xu, Liang; Ding, Jiao-teng; Wang, Yong-jie; Xie, Yong-jie; Ma, Zhen; Fan, Xue-wu

    2016-10-01

    Due to low density, high stiffness, low thermal expansion coefficient, duplicate molding, etc., carbon fiber reinforced polymer (CFRP) is one of the potential materials of the optical mirror. The process developed for Φ300mm high precision CFRP mirror described in this paper. A placement tool used to improve laying accuracy up to ± 0.1°.A special reinforced cell structure designed to increase rigidity and thermal stability. Optical replication process adopted for surface modification of the carbon fiber composite mirror blank. Finally, surface accuracy RMS of Φ300mm CFRP mirror is 0.22μm, surface roughness Ra is about 2nm, and the thermal stability can achieve 13nm /°C from the test result. The research content is of some reference value in the infrared as well as visible light applications.

  14. High Precision Assembly Line Synthesis for Molecules with Tailored Shapes

    PubMed Central

    Burns, Matthew; Essafi, Stephanie; Bame, Jessica R.; Bull, Stephanie P.; Webster, Matthew P.; Balieu, Sebastien; Dale, James W.; Butts, Craig P.; Harvey, Jeremy N.; Aggarwal, Varinder K.

    2014-01-01

    Molecular assembly lines, where molecules undergo iterative processes involving chain elongation and functional group manipulation are hallmarks of many processes found in Nature. We have sought to emulate Nature in the development of our own molecular assembly line through iterative homologations of boronic esters. Here we report a reagent (α-lithioethyl triispopropylbenzoate) which inserts into carbon-boron bonds with exceptionally high fidelity and stereocontrol. Through repeated iteration we have converted a simple boronic ester into a complex molecule (a carbon chain with ten contiguous methyl groups) with remarkably high precision over its length, its stereochemistry and therefore its shape. Different stereoisomers were targeted and it was found that they adopted different shapes (helical/linear) according to their stereochemistry. This work should now enable scientists to rationally design and create molecules with predictable shape, which could have an impact in all areas of molecular sciences where bespoke molecules are required. PMID:25209797

  15. High precision variational calculations of few-electron atoms

    NASA Astrophysics Data System (ADS)

    Bubin, Sergiy

    2015-05-01

    High precision calculations of energy levels and other properties of small atoms and ions have been a subject of fruitful interplay between the experiment and theory. However, most calculation of spectroscopic accuracy, until recently, have been possible only for two- and three-electron systems. In this talk I will report on progress toward performing high accuracy calculations of larger atomic systems (up to four-six electrons). The results of benchmark quality are attainable with the use of variational expansions in terms of all-particle explicitly correlated Gaussians, whose nonlinear variational parameters are extensively optimized. I will demonstrate what level of accuracy is available today for few-electron atoms and discuss the issues that must be overcome in order to extend the capability of the method to even larger systems. This work has been supported by the Ministry of Education and Science of Kazakhstan.

  16. High-precision analysis of the solar twin HIP 100963

    NASA Astrophysics Data System (ADS)

    Yana Galarza, Jhon; Meléndez, Jorge; Ramírez, Ivan; Yong, David; Karakas, Amanda I.; Asplund, Martin; Liu, Fan

    2016-05-01

    Context. HIP 100963 was one of the first solar twins identified. Although some high-precision analyses are available, a comprehensive high-precision study of chemical elements from different nucleosynthetic sources is still lacking from which to obtain potential new insights on planets, stellar evolution, and Galactic chemical evolution (GCE). Aims: We analyze and investigate the origin of the abundance pattern of HIP 100963 in detail, in particular the pattern of the light element Li, the volatile and refractory elements, and heavy elements from the s- and r-processes. Methods: We used the HIRES spectrograph on the Keck I telescope to acquire high-resolution (R ≈ 70 000) spectra with a high signal-to-noise ratio (S/N ≈ 400-650 per pixel) of HIP 100963 and the Sun for a differential abundance analysis. We measured the equivalent widths (EWs) of iron lines to determine the stellar parameters by employing the differential spectroscopic equilibrium. We determined the composition of volatile, refractory, and neutron-capture elements through a differential abundance analysis with respect to the Sun. Results: The stellar parameters we found are Teff = 5818 ± 4 K, log g = 4.49 ± 0.01 dex, vt = 1.03 ± 0.01km s-1, and [Fe/H] = -0.003 ± 0.004 dex. These low errors allow us to compute a precise mass (1.03+0.02-0.01 M⊙) and age (2.0 ± 0.4 Gyr), obtained using Yonsei-Yale isochrones. Using our [Y/Mg] ratio, we have determined an age of 2.1 ± 0.4 Gyr, in agreement with the age computed using isochrones. Our isochronal age also agrees with the age determined from stellar activity (2.4 ± 0.3 Gyr). We study the abundance pattern with condensation temperature (Tcond) taking corrections by the GCE into account. We show that the enhancements of neutron-capture elements are explained by contributions from both the s- and r-process. The lithium abundance follows the tight Li-age correlation seen in other solar twins. Conclusions: We confirm that HIP 100963 is a solar twin

  17. HIGH PRECISION ROVIBRATIONAL SPECTROSCOPY OF OH{sup +}

    SciTech Connect

    Markus, Charles R.; Hodges, James N.; Perry, Adam J.; Kocheril, G. Stephen; McCall, Benjamin J.; Müller, Holger S. P.

    2016-02-01

    The molecular ion OH{sup +} has long been known to be an important component of the interstellar medium. Its relative abundance can be used to indirectly measure cosmic ray ionization rates of hydrogen, and it is the first intermediate in the interstellar formation of water. To date, only a limited number of pure rotational transitions have been observed in the laboratory making it necessary to indirectly calculate rotational levels from high-precision rovibrational spectroscopy. We have remeasured 30 transitions in the fundamental band with MHz-level precision, in order to enable the prediction of a THz spectrum of OH{sup +}. The ions were produced in a water cooled discharge of O{sub 2}, H{sub 2}, and He, and the rovibrational transitions were measured with the technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy. These values have been included in a global fit of field free data to a {sup 3}Σ{sup −} linear molecule effective Hamiltonian to determine improved spectroscopic parameters which were used to predict the pure rotational transition frequencies.

  18. High precision optomechanical assembly using threads as mechanical reference

    NASA Astrophysics Data System (ADS)

    Lamontagne, Frédéric; Desnoyers, Nichola; Bergeron, Guy; Cantin, Mario

    2016-09-01

    A convenient method to assemble optomechanical components is to use threaded interface. For example, lenses are often secured inside barrels using threaded rings. In other cases, multiple optical sub-assemblies such as lens barrels can be threaded to each other. Threads have the advantage to provide a simple assembly method, to be easy to manufacture, and to offer a compact mechanical design. On the other hand, threads are not considered to provide accurate centering between parts because of the assembly clearance between the inner and outer threads. For that reason, threads are often used in conjunction with precision cylindrical surfaces to limit the radial clearance between the parts to be centered. Therefore, tight manufacturing tolerances are needed on these pilot diameters, which affect the cost of the optical assembly. This paper presents a new optomechanical approach that uses threads as mechanical reference. This innovative method relies on geometric principles to auto-center parts to each other with a very low centering error that is usually less than 5 μm. The method allows to auto-center an optical group in a main barrel, to perform an axial adjustment of an optical group inside a main barrel, and to perform stacking of multiple barrels. In conjunction with the lens auto-centering method that also used threads as a mechanical reference, this novel solution opens new possibilities to realize a variety of different high precision optomechanical assemblies at lower cost.

  19. Developing and implementing a high precision setup system

    NASA Astrophysics Data System (ADS)

    Peng, Lee-Cheng

    The demand for high-precision radiotherapy (HPRT) was first implemented in stereotactic radiosurgery using a rigid, invasive stereotactic head frame. Fractionated stereotactic radiotherapy (SRT) with a frameless device was developed along a growing interest in sophisticated treatment with a tight margin and high-dose gradient. This dissertation establishes the complete management for HPRT in the process of frameless SRT, including image-guided localization, immobilization, and dose evaluation. The most ideal and precise positioning system can allow for ease of relocation, real-time patient movement assessment, high accuracy, and no additional dose in daily use. A new image-guided stereotactic positioning system (IGSPS), the Align RT3C 3D surface camera system (ART, VisionRT), which combines 3D surface images and uses a real-time tracking technique, was developed to ensure accurate positioning at the first place. The uncertainties of current optical tracking system, which causes patient discomfort due to additional bite plates using the dental impression technique and external markers, are found. The accuracy and feasibility of ART is validated by comparisons with the optical tracking and cone-beam computed tomography (CBCT) systems. Additionally, an effective daily quality assurance (QA) program for the linear accelerator and multiple IGSPSs is the most important factor to ensure system performance in daily use. Currently, systematic errors from the phantom variety and long measurement time caused by switching phantoms were discovered. We investigated the use of a commercially available daily QA device to improve the efficiency and thoroughness. Reasonable action level has been established by considering dosimetric relevance and clinic flow. As for intricate treatments, the effect of dose deviation caused by setup errors remains uncertain on tumor coverage and toxicity on OARs. The lack of adequate dosimetric simulations based on the true treatment coordinates from

  20. Renal and glycemic effects of high-dose chromium picolinate in db/db mice: assessment of DNA damage.

    PubMed

    Mozaffari, Mahmood S; Baban, Babak; Abdelsayed, Rafik; Liu, Jun Yao; Wimborne, Hereward; Rodriguez, Nancy; Abebe, Worku

    2012-08-01

    This study examined renal and glycemic effects of chromium picolinate [Cr(pic)3] supplementation in the context of its purported potential for DNA damage. In preventional protocol, male obese diabetic db/db mice were fed diets either lacking or containing 5, 10 or 100 mg/kg chromium as Cr(pic)3 from 6 to 24 weeks of age; male lean nondiabetic db/m mice served as controls. Untreated db/db mice displayed increased plasma glucose and insulin, hemoglobin A1c, renal tissue advanced glycation end products, albuminuria, glomerular mesangial expansion, urinary 8-hydroxydeoxyguanosine (an index of oxidative DNA damage) and renal tissue immunostaining for γH2AX (a marker of double-strand DNA breaks) compared to db/m controls. Creatinine clearance was lower in untreated db/db mice than their db/m controls, while blood pressure was similar. High Cr(pic)3 intake (i.e., 100-mg/kg diet) mildly improved glycemic status and albuminuria without affecting blood pressure or creatinine clearance. Treatment with Cr(pic)3 did not increase DNA damage despite marked renal accumulation of chromium. In interventional protocol, effects of diets containing 0, 100 and 250 mg/kg supplemental chromium, from 12 to 24 weeks of age, were examined in db/db mice. The results generally revealed similar effects to those of the 100-mg/kg diet of the preventional protocol. In conclusion, the severely hyperglycemic db/db mouse displays renal structural and functional abnormalities in association with DNA damage. High-dose Cr(pic)3 treatment mildly improves glycemic control, and it causes moderate reduction in albuminuria, without affecting the histopathological appearance of the kidney and increasing the risk for DNA damage.

  1. Precision judgment criteria and supplement data processing method in high-precision ranging with dual-comb lasers

    NASA Astrophysics Data System (ADS)

    Zhou, Qian; Li, Yang; Ni, Kai; Xu, Mingfei; Dong, Hao; Wu, Guanhao

    2014-11-01

    A method using a pair of femtosecond frequency combs can realize ranging at a high precision of 1μm by Fourier Processing. In simulation of this system based on Matlab/Simulink, it is found that the choosing of repeating frequencies has great impact on frequency of the sampled signals, which influences the ranging precision a lot. The sampled signals are analyzed and classified into three types, which can be judgment criteria in system setting. Filter at Nyquist frequency is advised to decrease the edge effect of FFT, and a supplement means of cutting in data processing is proposed to improve precision.

  2. Simultaneous Precision Gravimetry and Magnetic Gradiometry with a Bose-Einstein Condensate: A High Precision, Quantum Sensor

    NASA Astrophysics Data System (ADS)

    Hardman, K. S.; Everitt, P. J.; McDonald, G. D.; Manju, P.; Wigley, P. B.; Sooriyabandara, M. A.; Kuhn, C. C. N.; Debs, J. E.; Close, J. D.; Robins, N. P.

    2016-09-01

    A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A 5 ×1 06 atom F =1 spinor condensate of 87Rb is released into free fall for up to 750 ms and probed with a T =130 ms Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states |mf=1 ,0 ,-1 ⟩, facilitating a simultaneous measurement of the acceleration due to gravity with a 1000 run precision of Δ g /g =1.45 ×10-9 and the magnetic field gradient to a precision of 120 pT /m .

  3. Monolithic interferometer for high precision radial velocity measurements

    NASA Astrophysics Data System (ADS)

    Wan, Xiaoke; Ge, Jian; Wang, Ji; Lee, Brian

    2009-08-01

    In high precision radial velocity (RV) measurements for extrasolar planets searching and studies, a stable wide field Michelson interferometer is very critical in Exoplanet Tracker (ET) instruments. Adopting a new design, monolithic interferometers are homogenous and continuous in thermal expansion, and field compensation and thermal compensation are both satisfied. Interferometer design and fabrication are decrypted in details. In performance evaluations, field angle is typically 22° and thermal sensitivity is typically -1.7 x 10-6/°C, which corresponds to ~500 m/s /°C in RV scale. In interferometer stability monitoring using a wavelength stabilized laser source, phase shift data was continuously recorded for nearly seven days. Appling a frequent calibration every 30 minutes as in typical star observations, the interferometer instability contributes less than 1.4 m/s in RV error, in a conservative estimation.

  4. Superconducting Tunnel Junctions for High-Precision EUV Spectroscopy

    NASA Astrophysics Data System (ADS)

    Ponce, F.; Carpenter, M. H.; Cantor, R.; Friedrich, S.

    2016-08-01

    We have characterized the photon response of superconducting tunnel junctions in the extreme ultraviolet energy range below 100 eV with a pulsed 355 nm laser. The detectors are operated at rates up to 5000 counts/s, are very linear in energy and have an energy resolution between 0.9 and 2 eV. We observe multiple peaks that correspond to an integer number of photons with a Poissonian probability distribution and that can be used for high-accuracy energy calibration. The uncertainty of the centroid depends on the detector resolution and the counting statistics and can be as low as 1 meV for well-separated peaks with >10^5 counts. We discuss the precision of the peak centroid as a function of detector resolution and total number of counts and the accuracy of the energy calibration.

  5. Thermal-mechanical behavior of high precision composite mirrors

    NASA Astrophysics Data System (ADS)

    Kuo, C. P.; Lou, M. C.; Rapp, D.

    1993-04-01

    Composite mirror panels were designed, constructed, analyzed, and tested in the framework of a NASA precision segmented reflector task. The deformations of the reflector surface during the exposure to space enviroments were predicted using a finite element model. The composite mirror panels have graphite-epoxy or graphite-cyanate facesheets, separated by an aluminum or a composite honeycomb core. It is pointed out that in order to carry out detailed modeling of composite mirrors with high accuracy, it is necessary to have temperature dependent properties of the materials involved and the type and magnitude of manufacturing errors and material nonuniformities. The structural modeling and analysis efforts addressed the impact of key design and materials parameters on the performance of mirrors.

  6. A high precision semi-analytic mass function

    NASA Astrophysics Data System (ADS)

    Del Popolo, Antonino; Pace, Francesco; Le Delliou, Morgan

    2017-03-01

    In this paper, extending past works of Del Popolo, we show how a high precision mass function (MF) can be obtained using the excursion set approach and an improved barrier taking implicitly into account a non-zero cosmological constant, the angular momentum acquired by tidal interaction of proto-structures and dynamical friction. In the case of the ΛCDM paradigm, we find that our MF is in agreement at the 3% level to Klypin's Bolshoi simulation, in the mass range Mvir = 5 × 109 h‑1Msolar–‑5 × 1014 h‑1Msolar and redshift range 0 lesssim z lesssim 10. For z = 0 we also compared our MF to several fitting formulae, and found in particular agreement with Bhattacharya's within 3% in the mass range 1012–1016 h‑1Msolar. Moreover, we discuss our MF validity for different cosmologies.

  7. Precision Viticulture from Multitemporal, Multispectral Very High Resolution Satellite Data

    NASA Astrophysics Data System (ADS)

    Kandylakis, Z.; Karantzalos, K.

    2016-06-01

    In order to exploit efficiently very high resolution satellite multispectral data for precision agriculture applications, validated methodologies should be established which link the observed reflectance spectra with certain crop/plant/fruit biophysical and biochemical quality parameters. To this end, based on concurrent satellite and field campaigns during the veraison period, satellite and in-situ data were collected, along with several grape samples, at specific locations during the harvesting period. These data were collected for a period of three years in two viticultural areas in Northern Greece. After the required data pre-processing, canopy reflectance observations, through the combination of several vegetation indices were correlated with the quantitative results from the grape/must analysis of grape sampling. Results appear quite promising, indicating that certain key quality parameters (like brix levels, total phenolic content, brix to total acidity, anthocyanin levels) which describe the oenological potential, phenolic composition and chromatic characteristics can be efficiently estimated from the satellite data.

  8. A detector interferometric calibration experiment for high precision astrometry

    NASA Astrophysics Data System (ADS)

    Crouzier, A.; Malbet, F.; Henault, F.; Léger, A.; Cara, C.; LeDuigou, J. M.; Preis, O.; Kern, P.; Delboulbe, A.; Martin, G.; Feautrier, P.; Stadler, E.; Lafrasse, S.; Rochat, S.; Ketchazo, C.; Donati, M.; Doumayrou, E.; Lagage, P. O.; Shao, M.; Goullioud, R.; Nemati, B.; Zhai, C.; Behar, E.; Potin, S.; Saint-Pe, M.; Dupont, J.

    2016-11-01

    Context. Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5 × 10-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on various pixel parameters. The minimization of function parameters was done iteratively, until convergence was obtained, revealing the pixel information needed for the calibration of astrometric measurements. Results: The calibration system yielded the pixel positions to an accuracy estimated at 4 × 10-4 pixel. After including the pixel position information, an astrometric accuracy of 6 × 10-5 pixel was obtained, for a PSF motion over more than five pixels. In the static mode (small jitter motion of less than 1 × 10-3 pixel), a photon noise limited precision of 3 × 10-5 pixel was reached.

  9. MultiView High Precision VLBI Astrometry at Low Frequencies

    NASA Astrophysics Data System (ADS)

    Rioja, María J.; Dodson, Richard; Orosz, Gabor; Imai, Hiroshi; Frey, Sandor

    2017-03-01

    The arrival of the Square Kilometer Array (SKA) will revitalize all aspects of Very Long Baseline Interferometry (VLBI) astronomy at lower frequencies. In the last decade, there have been huge strides toward routinely achieving high precision VLBI astrometry at frequencies dominated by tropospheric contributions, most notably at 22 GHz, using advanced phase-referencing techniques. Nevertheless, to increase the capability for high precision astrometric measurements at low radio frequencies (<8 GHz), an effective calibration strategy of the systematic ionospheric propagation effects that is widely applicable is required. Observations at low frequencies are dominated by distinct direction-dependent ionospheric propagation errors, which place a very tight limit on the angular separation of a suitable phase-referencing calibrator. The MultiView technique holds the key to compensating for atmospheric spatial-structure errors, by using observations of multiple calibrators and two-dimensional interpolation in the visibility domain. In this paper we present the first demonstration of the power of MultiView using three calibrators, several degrees from the target, along with a comparative study of the astrometric accuracy between MultiView and phase-referencing techniques. MultiView calibration provides an order of magnitude improvement in astrometry with respect to conventional phase referencing, achieving ∼100 μas astrometry errors in a single epoch of observations, effectively reaching the thermal noise limit. MultiView will achieve its full potential with the enhanced sensitivity and multibeam capabilities of SKA and the pathfinders, which will enable simultaneous observations of the target and calibrators. Our demonstration indicates that the 10 μas goal of astrometry at ∼1.6 GHz using VLBI with SKA is feasible using the MultiView technique.

  10. Dispersion modeling of particulate matter containing hexavalent chromium during high winds in southern Iraq.

    PubMed

    Zannetti, Paolo; Daly, Aaron D; Freedman, Frank R

    2015-02-01

    The aim of this paper is to describe a scientific methodology (i.e., the combination of different well-established modeling techniques) and its application to a real case scenario of contaminated dust emissions in high winds. This scenario addresses potential air pollution problems at the water treatment plant (WTP) at Qarmat-Ali, Basra, Iraq, during 2003. Workplace practices at the WTP before 2003 resulted in sodium dichromate contamination in the area. Looting at the site in early 2003 also contributed to this contamination. Individuals who were assigned to provide security at the site in 2003 have claimed adverse health effects caused by exposure to dust containing hexavalent chromium [Cr(VI)]. This report presents our modeling study with respect to these claims in relation to (1) amount of Cr(VI) present in the soil, (2) wind erosion episodes, and (3) possible long-term (e.g., annual average) Cr(VI) concentrations inhaled by different people while at the site. Our modeling approach included (1) the analysis of Cr(VI) soil measurements to assess the degree of contamination in different areas of the plant at different times; (2) the use of DUSTRAN model equations to calculate the emission rate of particulate matter (PM) less than 10 µm in diameter (PM10) during high-wind episodes; (3) the use of the U.S. Environmental Protection Agency (EPA) AERMOD modeling system to estimate Cr(VI) concentrations at the site; and (4) the calculation of modeling results in the form of both contour lines of average Cr(VI) concentrations at the site, and specific concentration values for selected individuals, based upon their recollection of their visits to the site.

  11. High lubricious surface of cobalt-chromium-molybdenum alloy prepared by grafting poly(2-methacryloyloxyethyl phosphorylcholine).

    PubMed

    Kyomoto, Masayuki; Iwasaki, Yasuhiko; Moro, Toru; Konno, Tomohiro; Miyaji, Fumiaki; Kawaguchi, Hiroshi; Takatori, Yoshio; Nakamura, Kozo; Ishihara, Kazuhiko

    2007-07-01

    Osteolysis caused by wear particles from polyethylene in artificial hip joints is of great concern. Various bearing couple combinations, bearing material improvements, and surface modifications have been attempted to reduce such wear particles. With the aim of reducing the wear and developing a novel artificial hip-joint system, we created a highly lubricious metal-bearing material: A 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer was grafted onto the surface of the cobalt-chromium-molybdenum (Co-Cr-Mo) alloy. For ensuring the long-term retention of poly(MPC) on the Co-Cr-Mo alloy, we used a 4-methacryloxyethyl trimellitate anhydride (4-META) intermediate layer and photo-induced graft polymerization technique to create a strong bonding between the Co-Cr-Mo substrate and the poly(MPC) chain via the 4-META layer. The Co-Cr-Mo alloy was pretreated with nitric acid and O(2) plasma to facilitate efficient interaction between the 4-META carboxyl group and the surface hydroxyl group on the Cr oxide passive layer of the Co-Cr-Mo alloy. After MPC grafting, the MPC unit peaks were clearly observed in the Fourier-transform infrared spectroscopy with attenuated total reflection (FT-IR/ATR) and X-ray photoelectron spectroscopy (XPS) spectra of the Co-Cr-Mo surface. Tribological studies with a pin-on-plate machine revealed that surface MPC grafting markedly lowered the friction coefficient. We concluded that the grafted poly(MPC) layer successfully provided high lubricity to the Co-Cr-Mo surface.

  12. Describing Oscillations of High Energy Neutrinos in Matter Precisely

    SciTech Connect

    Akhmedov, E.Kh.; Maltoni, M.; Smirnov, A.Yu.

    2005-11-18

    We present a formalism for precise description of oscillation phenomena in matter at high energies or high densities, V>{delta}m{sup 2}/2E, where V is the matter-induced potential of neutrinos. The accuracy of the approximation is determined by the quantity sin{sup 2}2{theta}{sub m}{delta}V/2{pi}V, where {theta}{sub m} is the mixing angle in matter and {delta}V is a typical change of the potential over the oscillation length (l{approx}2{pi}/V). We derive simple and physically transparent formulas for the oscillation probabilities, which are valid for arbitrary matter density profiles. They can be applied to oscillations of high-energy (E>10 GeV) accelerator, atmospheric, and cosmic neutrinos in the matter of the Earth, substantially simplifying numerical calculations and providing an insight into the physics of neutrino oscillations in matter. The effect of parametric enhancement of the oscillations of high-energy neutrinos is considered.

  13. Precision muon tracking detectors for high-energy hadron colliders

    NASA Astrophysics Data System (ADS)

    Gadow, Ph.; Kortner, O.; Kroha, H.; Richter, R.

    2017-02-01

    Small-diameter muon drift tube (sMDT) chambers with 15 mm tube diameter are a cost-effective technology for high-precision muon tracking over large areas at high background rates as expected at future high-energy hadron colliders including HL-LHC. The chamber design and construction procedures have been optimised for mass production and provide sense wire positioning accuracy of better than 10 μm. The rate capability of the sMDT chambers has been extensively tested at the CERN Gamma Irradiation Facility. It exceeds the one of the ATLAS muon drift tube (MDT) chambers, which are operated at unprecedentedly high background rates of neutrons and γ-rays, by an order of magnitude, which is sufficient for almost the whole of the muon detector acceptance at FCC-hh at maximum luminosity. sMDT operational and construction experience exists from ATLAS muon spectrometer upgrades which are in progress or under preparation for LHC Phase 1 and 2.

  14. Fast, High-Precision Readout Circuit for Detector Arrays

    NASA Technical Reports Server (NTRS)

    Rider, David M.; Hancock, Bruce R.; Key, Richard W.; Cunningham, Thomas J.; Wrigley, Chris J.; Seshadri, Suresh; Sander, Stanley P.; Blavier, Jean-Francois L.

    2013-01-01

    The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

  15. Quantification of total chromium and hexavalent chromium in UHT milk by ETAAS.

    PubMed

    Lameiras, J; Soares, M E; Bastos, M L; Ferreira, M

    1998-10-01

    Procedures for the quantification of total chromium and hexavalent chromium in UHT milk samples are presented. Total chromium was determined directly in milk with the addition of a surfactant and a mixture of Pd and Mg as a chemical modifier. For the selective separation of hexavalent chromium, the sample pre-treatment consisted in precipitation of proteins and elution of the supernatant through a Chromabond NH2 column. The metal was eluted with nitric acid. Both total chromium and hexavalent chromium were evaluated by atomic absorption spectrometry with electrothermal atomization using the same instrumental conditions. The detection limits were 0.2 and 0.15 microgram l-1 for total chromium and hexavalent chromium, respectively. The linearity ranges under the optimized conditions were 0.2-20 and 0.15-50 micrograms l-1. For total chromium the precision was 4.9 and 5.7% for the analytical and the over-all procedure, respectively, and for hexavalent chromium 4.3 and 4.9%, respectively. The validation of both procedures was performed by the standard additions method and the recoveries were higher than 93% in all cases. For total chromium, a certified reference material was also used to validate the methodology. The methods were applied to the determination of total chromium and hexavalent chromium in 60 UHT milk samples.

  16. Gamma titanium aluminide rendered castable by low chromium and high niobium additives

    SciTech Connect

    Shyh-Chin Huang.

    1993-05-25

    A castable composition is described comprising titanium, aluminum, chromium, and niobium in the following approximate composition: Ti-Al[sub 46]-[sub 48]Cr[sub 1-3]Nb[sub 6-14]; said alloy having been prepared by cast and HIP processing.

  17. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    SciTech Connect

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  18. Evaluation of High-Precision Sensors in Structural Monitoring

    PubMed Central

    Erol, Bihter

    2010-01-01

    One of the most intricate branches of metrology involves the monitoring of displacements and deformations of natural and anthropogenic structures under environmental forces, such as tidal or tectonic phenomena, or ground water level changes. Technological progress has changed the measurement process, and steadily increasing accuracy requirements have led to the continued development of new measuring instruments. The adoption of an appropriate measurement strategy, with proper instruments suited for the characteristics of the observed structure and its environmental conditions, is of high priority in the planning of deformation monitoring processes. This paper describes the use of precise digital inclination sensors in continuous monitoring of structural deformations. The topic is treated from two viewpoints: (i) evaluation of the performance of inclination sensors by comparing them to static and continuous GPS observations in deformation monitoring and (ii) providing a strategy for analyzing the structural deformations. The movements of two case study objects, a tall building and a geodetic monument in Istanbul, were separately monitored using dual-axes micro-radian precision inclination sensors (inclinometers) and GPS. The time series of continuous deformation observations were analyzed using the Least Squares Spectral Analysis Technique (LSSA). Overall, the inclinometers showed good performance for continuous monitoring of structural displacements, even at the sub-millimeter level. Static GPS observations remained insufficient for resolving the deformations to the sub-centimeter level due to the errors that affect GPS signals. With the accuracy advantage of inclination sensors, their use with GPS provides more detailed investigation of deformation phenomena. Using inclinometers and GPS is helpful to be able to identify the components of structural responses to the natural forces as static, quasi-static, or resonant. PMID:22163499

  19. Evaluation of high-precision sensors in structural monitoring.

    PubMed

    Erol, Bihter

    2010-01-01

    One of the most intricate branches of metrology involves the monitoring of displacements and deformations of natural and anthropogenic structures under environmental forces, such as tidal or tectonic phenomena, or ground water level changes. Technological progress has changed the measurement process, and steadily increasing accuracy requirements have led to the continued development of new measuring instruments. The adoption of an appropriate measurement strategy, with proper instruments suited for the characteristics of the observed structure and its environmental conditions, is of high priority in the planning of deformation monitoring processes. This paper describes the use of precise digital inclination sensors in continuous monitoring of structural deformations. The topic is treated from two viewpoints: (i) evaluation of the performance of inclination sensors by comparing them to static and continuous GPS observations in deformation monitoring and (ii) providing a strategy for analyzing the structural deformations. The movements of two case study objects, a tall building and a geodetic monument in Istanbul, were separately monitored using dual-axes micro-radian precision inclination sensors (inclinometers) and GPS. The time series of continuous deformation observations were analyzed using the Least Squares Spectral Analysis Technique (LSSA). Overall, the inclinometers showed good performance for continuous monitoring of structural displacements, even at the sub-millimeter level. Static GPS observations remained insufficient for resolving the deformations to the sub-centimeter level due to the errors that affect GPS signals. With the accuracy advantage of inclination sensors, their use with GPS provides more detailed investigation of deformation phenomena. Using inclinometers and GPS is helpful to be able to identify the components of structural responses to the natural forces as static, quasi-static, or resonant.

  20. Developing Performance Estimates for High Precision Astrometry with TMT

    NASA Astrophysics Data System (ADS)

    Schoeck, Matthias; Do, Tuan; Ellerbroek, Brent; Herriot, Glen; Meyer, Leo; Suzuki, Ryuji; Wang, Lianqi; Yelda, Sylvana

    2013-12-01

    Adaptive optics on Extremely Large Telescopes will open up many new science cases or expand existing science into regimes unattainable with the current generation of telescopes. One example of this is high-precision astrometry, which has requirements in the range from 10 to 50 micro-arc-seconds for some instruments and science cases. Achieving these requirements imposes stringent constraints on the design of the entire observatory, but also on the calibration procedures, observing sequences and the data analysis techniques. This paper summarizes our efforts to develop a top down astrometry error budget for TMT. It is predominantly developed for the first-light AO system, NFIRAOS, and the IRIS instrument, but many terms are applicable to other configurations as well. Astrometry error sources are divided into 5 categories: Reference source and catalog errors, atmospheric refraction correction errors, other residual atmospheric effects, opto-mechanical errors and focal plane measurement errors. Results are developed in parametric form whenever possible. However, almost every error term in the error budget depends on the details of the astrometry observations, such as whether absolute or differential astrometry is the goal, whether one observes a sparse or crowded field, what the time scales of interest are, etc. Thus, it is not possible to develop a single error budget that applies to all science cases and separate budgets are developed and detailed for key astrometric observations. Our error budget is consistent with the requirements for differential astrometry of tens of micro-arc-seconds for certain science cases. While no show stoppers have been found, the work has resulted in several modifications to the NFIRAOS optical surface specifications and reference source design that will help improve the achievable astrometry precision even further.

  1. Highly precise and robust packaging of optical components

    NASA Astrophysics Data System (ADS)

    Leers, Michael; Winzen, Matthias; Liermann, Erik; Faidel, Heinrich; Westphalen, Thomas; Miesner, Jörn; Luttmann, Jörg; Hoffmann, Dieter

    2012-03-01

    In this paper we present the development of a compact, thermo-optically stable and vibration and mechanical shock resistant mounting technique by soldering of optical components. Based on this technique a new generation of laser sources for aerospace applications is designed. In these laser systems solder technique replaces the glued and bolted connections between optical component, mount and base plate. Alignment precision in the arc second range and realization of long term stability of every single part in the laser system is the main challenge. At the Fraunhofer Institute for Laser Technology ILT a soldering and mounting technique has been developed for high precision packaging. The specified environmental boundary conditions (e.g. a temperature range of -40 °C to +50 °C) and the required degrees of freedom for the alignment of the components have been taken into account for this technique. In general the advantage of soldering compared to gluing is that there is no outgassing. In addition no flux is needed in our special process. The joining process allows multiple alignments by remelting the solder. The alignment is done in the liquid phase of the solder by a 6 axis manipulator with a step width in the nm range and a tilt in the arc second range. In a next step the optical components have to pass the environmental tests. The total misalignment of the component to its adapter after the thermal cycle tests is less than 10 arc seconds. The mechanical stability tests regarding shear, vibration and shock behavior are well within the requirements.

  2. Semi-solid processing of high-chromium tool steel to obtain microstructures without carbide network

    NASA Astrophysics Data System (ADS)

    Jirková, H.; Aišman, D.; Rubešová, K.; Opatová, K.; Mašek, B.

    2017-02-01

    Treatment of high-alloy tool steels that involves transition to the semi-solid state can transform the sharp-edged primary carbides which usually form during solidification. These carbides severely impair toughness and are virtually impossible to eliminate by conventional treatment routes. Upon classical semi-solid processing which dissolves these carbides, the resulting microstructure consists of polyhedral and super-saturated austenite embedded in lamellar austenite-carbide network. This type of microstructure reflects in the mechanical properties, predominantly in material behaviour under tensile loading. Such a network, however, can be removed by appropriate thermomechanical treatment. In the present experiment, various procedures involving heating to the semi-solid state were tested on X210Cr12 tool steel. The feedstock was heated to the temperature range of 1220 – 1280 °C. The heating was followed by procedures involving either water quenching to the forming temperature, room temperature or temperature from the range from 500 °C to 1000 °C followed by reheating to the forming temperature. It was found that the development of the lamellar network strongly depends on the temperature of heating to semi-solid state. Thermomechanical treatment produced microstructures in which the matrix consisted of a mixture of polyhedral austenite grains and the M-A constituent. In addition, the initial lamellar eutectic network was partially or even completely melted and substituted with a mixture of very fine recrystallized austenite grains and precipitates of chromium carbides. Some fine M7C3 carbides were present in the austenitic-martensitic matrix as well. When appropriate processing parameters were chosen, very good mechanical properties were obtained, among them a hardness of 860 HV10.

  3. High-precision efficiency calibration of a high-purity co-axial germanium detector

    NASA Astrophysics Data System (ADS)

    Blank, B.; Souin, J.; Ascher, P.; Audirac, L.; Canchel, G.; Gerbaux, M.; Grévy, S.; Giovinazzo, J.; Guérin, H.; Nieto, T. Kurtukian; Matea, I.; Bouzomita, H.; Delahaye, P.; Grinyer, G. F.; Thomas, J. C.

    2015-03-01

    A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and γ-ray source measurements have been compared to Monte-Carlo simulations to adjust the dimensions of a detector model. For this purpose, standard calibration sources and short-lived online sources have been used. The resulting efficiency calibration reaches the precision needed e.g. for branching ratio measurements of super-allowed β decays for tests of the weak-interaction standard model.

  4. A simple high-precision Jacob's staff design for the high-resolution stratigrapher

    USGS Publications Warehouse

    Elder, W.P.

    1989-01-01

    The new generation of high-resolution stratigraphic research depends upon detailed bed-by-bed analysis to enhance regional correlation potential. The standard Jacob's staff is not an efficient and precise tool for measuring thin-bedded strata. The high-precision Jacob's staff design presented and illustrated in this paper meets the qualifications required of such an instrument. The prototype of this simple design consists of a sliding bracket that holds a Brunton-type compass at right angles to a ruled-off staff. This instrument provides rapid and accurate measurement of both thick- or thin-bedded sequences, thus decreasing field time and increasing stratigraphic precision. -Author

  5. High-Precision Measurement of the Proton's Atomic Mass

    NASA Astrophysics Data System (ADS)

    Heiße, F.; Köhler-Langes, F.; Rau, S.; Hou, J.; Junck, S.; Kracke, A.; Mooser, A.; Quint, W.; Ulmer, S.; Werth, G.; Blaum, K.; Sturm, S.

    2017-07-01

    We report on the precise measurement of the atomic mass of a single proton with a purpose-built Penning-trap system. With a precision of 32 parts per trillion our result not only improves on the current CODATA literature value by a factor of 3, but also disagrees with it at a level of about 3 standard deviations.

  6. High-Precision Studies of Compact Variable Stars

    NASA Astrophysics Data System (ADS)

    Bloemen, Steven

    2014-10-01

    This book, which is a reworked and updated version of Steven Bloemen's original PhD thesis, reports on several high-precision studies of compact variable stars. Its strength lies in the large variety of observational, theoretical and instrumentation techniques that are presented and used and paves the way towards new and detailed asteroseismic applications of single and binary subdwarf stars. Close binary stars are studied using high cadence spectroscopic datasets collected with state of the art electron multiplying CCDs and analysed using Doppler tomography visualization techniques. The work touches upon instrumentation, presenting the calibration of a new fast, multi-colour camera installed at the Mercator Telescope on La Palma. The thesis also includes theoretical work on the computation of the temperature range in which stellar oscillations can be driven in subdwarf B-stars. Finally, the highlight of the thesis is the measurement of velocities of stars using only photometric data from NASA's Kepler satellite. Doppler beaming causes stars to appear slightly brighter when they move towards us in their orbits, and this subtle effect can be seen in Kepler's brightness measurements. The thesis presents the first validation of such velocity measurements using independent spectroscopic measurements. Since the detection and validation of this Doppler beaming effect, it has been used in tens of studies to detect and characterize binary star systems, which are key calibrators in stellar astronomy.

  7. High-precision heliostat for long-path light tracking

    NASA Astrophysics Data System (ADS)

    Hawat, Tom; Stephen, Thomas M.; DeMaziere, Martine M.; Neefs, Eddy

    2003-08-01

    A heliostat has been designed and built for use in optical remote sensing of the atmosphere. The heliostat uses two flat mirrors to track the sun and direct the sunlight to optical instruments. A stepper motor driven horizontal turntable is used to track the sun in azimuth and support an elevation assembly and a mechanical tower. The stepper motor driven elevation assembly drives an acquisition mirror that tracks the sun in elevation. This mirror directs the solar beam to a secondary mirror fixed on the mechanical tower. The secondary mirror then directs the solar beam along the axis of the tracker for use in measurements. A sensitive, high resolution CCD camera, receives a small part of the solar beam to analyze for fine servo-control. Ground based tests have demonstrated this instrument"s tracking capability for the sun, the moon, stars and for long pathlength sources. Presently, this system is coupled with a high-resolution Brucker 120M spectrometer used to obtain solar absorption spectra. The heliostat directs the solar radiation along the spectrometer optical axis. The pointing precision was measured to be better than 0.5 arcsec. A description of the heliostat is presented, as well as the results of ground tests.

  8. High-speed high-precision and ultralong-range complex spectral domain dimensional metrology.

    PubMed

    Bao, Wen; Shen, Yi; Chen, Tao; Li, Peng; Ding, Zhihua

    2015-05-04

    A precise, nondestructive dimensional metrological system is crucial to manufacturing and packaging of multi-component optical system. To this end, an orthogonal dispersive spectrometer based complex spectral domain interferometric system for high-speed high-precision and ultralong-range dimensional metrology is developed. An improved complex method based on actual spectral phase shift is proposed to achieve ultrahigh suppression of artifacts. Suppression ratios of 80 dB for DC and 60 dB for mirror images are realized, the highest ratios among existing complex methods. To ensure high-precision in distance determination, an averaged spectral phase measurement algorithm is adopted. A precision of 60 nm within a measurement range of 200 mm without axial movement of the sample is demonstrated. The measurement range is readily extendable if axial movement of the sample and range cascading are involved. The system holds potential applications in various areas for real-time nondestructive testing and evaluation.

  9. Precision cosmology with time delay lenses: high resolution imaging requirements

    SciTech Connect

    Meng, Xiao-Lei; Liao, Kai; Treu, Tommaso; Agnello, Adriano; Auger, Matthew W.; Marshall, Philip J. E-mail: tt@astro.ucla.edu E-mail: mauger@ast.cam.ac.uk E-mail: dr.phil.marshall@gmail.com

    2015-09-01

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as ''Einstein Rings'' in high resolution images. The distortion of these arcs and counter-arcs, as measured over a large number of pixels, provides tight constraints on the difference between the gravitational potential between the quasar image positions, and thus on cosmology in combination with the measured time delay. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope γ' of the total mass density profile ρ{sub tot}∝ r{sup −γ'} for the main deflector can be measured. Ideally, we require that the statistical error on γ' be less than 0.02, such that it is subdominant to other sources of random and systematic uncertainties. We find that survey data will likely have sufficient depth and resolution to meet the target only for the brighter gravitational lens systems, comparable to those discovered by the SDSS survey. For fainter systems, that will be discovered by current and future surveys, targeted follow-up will be required. However, the exposure time required with upcoming facilitites such as JWST, the Keck Next Generation Adaptive Optics System, and TMT, will

  10. Precision cosmology with time delay lenses: High resolution imaging requirements

    SciTech Connect

    Meng, Xiao -Lei; Treu, Tommaso; Agnello, Adriano; Auger, Matthew W.; Liao, Kai; Marshall, Philip J.

    2015-09-28

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as ``Einstein Rings'' in high resolution images. The distortion of these arcs and counter-arcs, as measured over a large number of pixels, provides tight constraints on the difference between the gravitational potential between the quasar image positions, and thus on cosmology in combination with the measured time delay. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope γ' of the total mass density profile ρtot∝ r–γ' for the main deflector can be measured. Ideally, we require that the statistical error on γ' be less than 0.02, such that it is subdominant to other sources of random and systematic uncertainties. We find that survey data will likely have sufficient depth and resolution to meet the target only for the brighter gravitational lens systems, comparable to those discovered by the SDSS survey. For fainter systems, that will be discovered by current and future surveys, targeted follow-up will be required. Furthermore, the exposure time required with upcoming facilitites such as JWST, the Keck Next Generation Adaptive Optics System, and TMT, will

  11. High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

    NASA Astrophysics Data System (ADS)

    Liss, J.; Dunagan, S. E.; Johnson, R. R.; Chang, C. S.; LeBlanc, S. E.; Shinozuka, Y.; Redemann, J.; Flynn, C. J.; Segal-Rosenhaimer, M.; Pistone, K.; Kacenelenbogen, M. S.; Fahey, L.

    2016-12-01

    High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera TrackingThe NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddard's AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sun/sky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS-14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a

  12. Supplementary chromium(III) propionate complex does not protect against insulin resistance in high-fat-fed rats.

    PubMed

    Król, Ewelina; Krejpcio, Zbigniew; Iwanik, Katarzyna

    2014-02-01

    Improper eating habits such as high-fat or high-carbohydrate diets are responsible for metabolic changes resulting in impaired glucose tolerance, hyperinsulinemia, insulin resistance, and ultimately diabetes. Although the essentiality of trivalent chromium for humans has been recently questioned by researchers, pharmacological dosages of this element can improve insulin sensitivity in experimental animals and diabetic subjects. The aim of the study was to assess the preventive potential of the supplementary chromium(III) propionate complex (CrProp) in rats fed a high-fat diet. The experiment was conducted on 32 male Wistar rats divided into four groups and fed the following diets: the control (C, AIN-93G), high-fat diets (HF, 40% energy from fat), and a high-fat diet supplemented with CrProp at dosages of 10 and 50 mg Cr/kg diet (HF + Cr10 and HF + Cr50, respectively). After 8 weeks, high-fat feeding led to an increased body mass, hyperinsulinemia, insulin resistance, a decreased serum urea concentration, accumulation of lipid droplets in hepatocytes, and increased renal Fe and splenic Cu contents. Supplementary CrProp in both dosages did not alleviate these changes but increased renal Cr content and normalized splenic Cu content in high-fat-fed rats. Supplementary CrProp does not prevent the development of insulin resistance in rats fed a high-fat diet.

  13. High-precision Mg isotopic systematics of bulk chondrites

    NASA Astrophysics Data System (ADS)

    Schiller, Martin; Handler, Monica R.; Baker, Joel A.

    2010-08-01

    Variations of the mass-independent abundance of 26Mg ( δ26Mg*) and stable Mg ( δ25Mg) isotope composition of chondrites are important because they constrain the homogeneity of 26Al and Mg isotopes in the proto-planetary disc and the validity of the short-lived 26Al-to- 26Mg chronometer applied to meteorites. We present high-precision Mg isotope data and Al/Mg ratios of chondrites representing nearly all major chondrite classes, including a step-leaching experiment on the CM2 chondrite Murchison. δ26Mg* variations in leachates of Murchison representing acid soluble material are ≤ 30 times smaller than reported for neutron-rich isotopes of Ti and Cr and do not reveal resolvable deficits in δ26Mg* (-0.002 to + 0.118‰). Very small variations in δ26Mg* anomalies in bulk chondrites (-0.006 to + 0.019‰) correlate with increasing 27Al/ 24Mg ratios and δ50Ti, reflecting the variable presence of calcium-aluminium-rich inclusions (CAIs) in some types of carbonaceous chondrites. Similarly, release of radiogenic 26Mg produced by 26Al decay from CAI material in the step-leaching of Murchison best explains the high δ26Mg* observed in the last, aggressive, leaching steps of this experiment. Overall, the observed variations in δ26Mg* are small and potential differences beyond that which result from the presence of CAI-like material cannot be detected within the analytical uncertainties of this study (± 0.004‰). The results do not allow radical heterogeneity of 26Al (≥±30%) or measurable Mg nucleosynthetic heterogeneity (≥±0.005‰) to have existed on a planetesimal scale in the proto-planetary disc. Combined with published δ26Mg* data for CAIs, the bulk chondrite data yield a precise initial ( 26Al/ 27Al) 0 = (5.21 ± 0.06) × 10 -5 and δ26Mg* = -0.0340 ± 0.0016‰ for the Solar System. However, it is not possible with the currently available data to determine with certainty whether CAIs and the material from which planetesimals accreted including

  14. High precision optical finishing of lightweight silicon carbide aspheric mirror

    NASA Astrophysics Data System (ADS)

    Kong, John; Young, Kevin

    2010-10-01

    Critical to the deployment of large surveillance optics into the space environment is the generation of high quality optics. Traditionally, aluminum, glass and beryllium have been used; however, silicon carbide becomes of increasing interest and availability due to its high strength. With the hardness of silicon carbide being similar to diamond, traditional polishing methods suffer from slow material removal rates, difficulty in achieving the desired figure and inherent risk of causing catastrophic damage to the lightweight structure. Rather than increasing structural capacity and mass of the substrate, our proprietary sub-aperture aspheric surface forming technology offers higher material removal rates (comparable to that of Zerodur or Fused Silica), a deterministic approach to achieving the desired figure while minimizing contact area and the resulting load on the optical structure. The technology performed on computer-controlled machines with motion control software providing precise and quick convergence of surface figure, as demonstrated by optically finishing lightweight silicon carbide aspheres. At the same time, it also offers the advantage of ideal pitch finish of low surface micro-roughness and low mid-spatial frequency error. This method provides a solution applicable to all common silicon carbide substrate materials, including substrates with CVD silicon carbide cladding, offered by major silicon carbide material suppliers. This paper discusses a demonstration mirror we polished using this novel technology. The mirror is a lightweight silicon carbide substrate with CVD silicon carbide cladding. It is a convex hyperbolic secondary mirror with 104mm diameter and approximately 20 microns aspheric departure from best-fit sphere. The mirror has been finished with surface irregularity of better than 1/50 wave RMS @632.8 nm and surface micro-roughness of under 2 angstroms RMS. The technology has the potential to be scaled up for manufacturing capabilities of

  15. High precision refractometry based on Fresnel diffraction from phase plates.

    PubMed

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  16. Laser interferometric high-precision angle monitor for JASMINE

    NASA Astrophysics Data System (ADS)

    Niwa, Yoshito; Arai, Koji; Sakagami, Masaaki; Gouda, Naoteru; Kobayashi, Yukiyasu; Yamada, Yoshiyuki; Yano, Taihei

    2006-06-01

    The JASMINE instrument uses a beam combiner to observe two different fields of view separated by 99.5 degrees simultaneously. This angle is so-called basic angle. The basic angle of JASMINE should be stabilized and fluctuations of the basic angle should be monitored with the accuracy of 10 microarcsec in root-mean-square over the satellite revolution period of 5 hours. For this purpose, a high-precision interferometric laser metrogy system is employed. One of the available techniques for measuring the fluctuations of the basic angle is a method known as the wave front sensing using a Fabry-Perot type laser interferometer. This technique is to detect fluctuations of the basic angle as displacement of optical axis in the Fabry-Perot cavity. One of the advantages of the technique is that the sensor is made to be sensitive only to the relative fluctuations of the basic angle which the JASMINE wants to know and to be insensitive to the common one; in order to make the optical axis displacement caused by relative motion enhanced the Fabry-Perot cavity is formed by two mirrors which have long radius of curvature. To verify the principle of this idea, the experiment was performed using a 0.1m-length Fabry-Perot cavity with the mirror curvature of 20m. The mirrors of the cavity were artificially actuated in either relative way or common way and the resultant outputs from the sensor were compared.

  17. Automated high precision variable aperture for spectrophotometer linearity testing.

    PubMed

    Zwinkels, J C; Gignac, D S

    1991-05-01

    A new automated linearity tester with a single variable aperture has been designed and built. It uses piezoelectric motors to define precisely the apertures required for application of the double aperture method of light addition. This design avoids many of the inherent shortcomings of two fixed physically separated apertures, such as interference and coherence between two separated beams and the need for an averaging sphere to compensate for beam noncoincidence at the photoreceiver. It also permits the assessment of system nonlinearity for arbitrary flux levels over an approximately 70:1 dynamic range without the use of a supplementary means of optical attenuation. The tester was specifically designed for use with the National Research Council of Canada Reference spectrophotometer, but it can be adapted for use with any instrument with a large stable measurement beam. The paper discusses the correct placement and operation of this device. The performance, as evaluated by nonlinearity measurements of a known highly linear silicon photodiode, shows a reliability of <1-3 parts in 10(4) over a 3400:1 dynamic range at a 97% confidence level. Several applications of this linearity tester to both photomultipliers and photodiodes are described. Transmittance results for several reference materials using these linearity corrected photodetectors are compared and show a typical agreement of better than 0.025% of the value.

  18. High-precision target location for industrial metrology

    NASA Astrophysics Data System (ADS)

    Cosandier, D.; Chapman, Michael A.

    1993-02-01

    Many industrial metrology applications require accurate and real or near-real time measurement tools in often adverse conditions. Over the past three years, the Industrial Alignment Project (IAP) has been focused on the development of precise measurement techniques for use with large rotating machinery. This paper highlights some results using digital array cameras which have been shown to be well suited for many applications. Limited camera resolution and high accuracy point positioning requirements have required the development of specialized targets. Retro-reflective targets are used to reduce the varying effects of lighting/shadows since this material exhibits maximum reflection in the direction of the light source. Using sub-pixel edge detection techniques with the pre-defined targets, it is possible to obtain accuracies of 1/20th a pixel or better. In addition, employing multiple camera stations with an appropriate imaging geometry, the three dimensional coordinates of the point of interest can be obtained by establishing photogrammetric techniques. The results of test projects are given to illustrate the viability of such a measuring system.

  19. Interferometric apparatus for ultra-high precision displacement measurement

    NASA Technical Reports Server (NTRS)

    Zhao, Feng (Inventor)

    2004-01-01

    A high-precision heterodyne interferometer measures relative displacement by creating a thermally-insensitive system generally not subject to polarization leakage. By using first and second light beams separated by a small frequency difference (.DELTA.f), beams of light at the first frequency (f.sub.0) are reflected by co-axial mirrors, the first mirror of which has a central aperture through which the light is transmitted to and reflected by the second mirror. Prior to detection, the light beams from the two mirrors are combined with light of the second and slightly different frequency. The combined light beams are separated according to the light from the mirrors. The change in phase (.DELTA..phi.) with respect to the two signals is proportional to the change in distance of Fiducial B by a factor of wavelength (.lambda.) divided by 4.pi. (.DELTA.L=.lambda..DELTA..phi.1/(4.pi.)). In a second embodiment, a polarizing beam splitting system can be used.

  20. HST high-precision proper motions of globular clusters

    NASA Astrophysics Data System (ADS)

    Bellini, Andrea; Anderson, Jay; van der marel, roeland p.; piotto, gianpaolo; Watkins, Laura l.; Vesperini, Enrico; Milone, Antonino; Bedin, Luigi R.

    2015-08-01

    The stable environment of space makes HST an excellent astrometric tool. Its diffraction-limited resolution allows it to distinguish and measure positions and fluxes for stars all the way to the center of most globular clusters. There are now many clusters that have observations in the archive that span 13 years or more, and more observations are being taken all the time. We constructed high-precision proper-motion catalogs for over 20 clusters for which there exist two or more well-separated epochs in the archive, and we are extending the list to over 60 objects, thanks to the new observations taken within the ``HST UV Legacy Survey of Galactic Globular Clusters’’ treasury program. Each catalog contains astrometry and photometry for thousands of stars within two arcmin of the center. The catalogs are focused on the many stars within a few magnitudes of the turnoff and have typical proper-motion errors of 0.1 mas/yr, which translates to 2 km/s for the typical cluster. We are using proper motions to directly measure the clusters' anisotropy, equipartition and rotation on the plane of the sky, as well as to study internal kinematics of the different subpopulations and to probe the presence of an IMBH in their core.

  1. High-Precision Single Photon Timing of Pulsars

    NASA Astrophysics Data System (ADS)

    Ransom, Scott M.; Ray, Paul S.; Kerr, Matthew

    2017-08-01

    We have developed a likelihood-based technique, implemented through Markov Chain Monte Carlo, that enables high-precision pulsar timing using individual x-rays or gamma-rays. Our current implementaion leverages the new timing software PINT for timing model details and provides several significant advantages over earlier, more traditional, timing techniques. Our method does not require the integration of an average pulse profile from which a "time of arrival" is computed. This is crucial when the photon count rates are too low to produce a good pulse profile on the timescales of other important timing properties of the system (such as an orbital period of a binary pulsar). Arbitrary weights can be applied to each photon to indicate, for instance, the probability that each event might be a background photon. Many other improvements are being developed, such as simultaneously determining the timing solution and a template profile and parallel calculation of the likelihoods. We have successfully applied the technique to a variety of Fermi pulsars and will be using it extensively for timing analyses during the NICER mission.

  2. Measuring Crustal Deformation in Europe by High Precision Geodetic VLBI

    NASA Astrophysics Data System (ADS)

    Campbell, J.; Nothnagel, A.; Vennebusch, M.

    2002-06-01

    At the western tip of the Eurasian plate, the European continent is besieged by thrusting and receding neighbour plates causing deformations and ruptures of the Earth's crust evidenced by earthquakes and volcanic outbursts. Measuring the extent and progress of crustal deformation has become one of the primary tasks of geodesists and geophysicists. Realizing that Europe enjoys one of the densest networks of radio telescopes especially equipped for high precision, geodetic VLBI has provided the incentive to organise a campaign of regular geodetic VLBI observations in the European network of fixed radio telescopes. The measurements have been carried out since the late eighties at an average rate of six sessions per year. From these data, site coordinates, baseline length changes and station velocity vectors have been derived with steadily increasing accuracy. The overall picture of the observed present-day site motions emulates quite well the pattern of tectonic motions inferred from the geotectonic setting of central Europe and the western Mediterranean. Interesting details are emerging for horizontal motions of the three stations in Italy, which are strongly affected by the complex interactions between the different tectonic regimes in this area. The accuracy of the vertical components is also improving with increasing length of the observational record, allowing to detect significant trends among the relative vertical motions of the sites. The geodetic VLBI network operations have received supportive funding by the European Union under the 2nd and 4th Framework Programmes.

  3. High precision predictions for exclusive VH production at the LHC

    DOE PAGES

    Li, Ye; Liu, Xiaohui

    2014-06-04

    We present a resummation-improved prediction for pp → VH + 0 jets at the Large Hadron Collider. We focus on highly-boosted final states in the presence of jet veto to suppress the tt¯ background. In this case, conventional fixed-order calculations are plagued by the existence of large Sudakov logarithms αnslogm(pvetoT/Q) for Q ~ mV + mH which lead to unreliable predictions as well as large theoretical uncertainties, and thus limit the accuracy when comparing experimental measurements to the Standard Model. In this work, we show that the resummation of Sudakov logarithms beyond the next-to-next-to-leading-log accuracy, combined with the next-to-next-to-leading ordermore » calculation, reduces the scale uncertainty and stabilizes the perturbative expansion in the region where the vector bosons carry large transverse momentum. Thus, our result improves the precision with which Higgs properties can be determined from LHC measurements using boosted Higgs techniques.« less

  4. High Precision 40K/39K Ratio Determination

    NASA Astrophysics Data System (ADS)

    Naumenko, M. O.; Mezger, K.; Nagler, T. F.; Villa, I. M.

    2012-12-01

    Potassium is one of the eight most abundant chemical elements in the Earth's crust and a major element in many rock-forming minerals. The isotope 40K is radioactive and undergoes β- decay to 40Ca (ca. 89.3%) and electron capture to 40Ar (ca. 10.7%). Both decays can potentially be used as dating systems. The most commonly used branch is the decay of 40K to 40Ar because it can yield highly precise ages. Both decay schemes rely on the knowledge of the 40K branching ratio and the natural 40K abundance. A 40K abundance of 0.011672±41 % was measured on terrestrial material [1]. The relative uncertainty of 0.35 % has not been improved since. Recent improvements in the precision of mass spectrometric measurements have led to the situation that the uncertainties on the K decay constant and the abundance of 40K are a major source of uncertainty on the measured ages. A more precise definition of the 40K decay constant was attempted by different research groups within the last decade [2-9] but the goal of obtaining 0.1 % relative uncertainty on K-Ar ages for geological materials, as requested by the EARTHtime initiative, has not been achieved yet. In order to improve on this situation we studied the abundances of the K isotopes in terrestrial standards. A ThermoFischer Triton+ thermal ionisation mass spectrometer was used for K isotope ratio measurements of the NIST SRM 918b K standard loaded on Ta filaments with 0.1M phosphoric acid. Three techniques were applied: (A) dynamic measurement with in-run normalisation to the IUPAC value 41K/39K=0.072168; (B) a simple total evaporation procedure; (C) the "NBL-modified" total evaporation [10]. The 40K ion beam was measured in a Faraday cup with a 1E12 Ω resistor; 39K and 41K were collected in Faraday cups with 1E11 Ω resistors. Amplifier gains were intercalibrated by supplying fixed voltages off-line. Different measurement techniques were combined with different loading procedures. We also tested ionisation yields for the

  5. High-precision VLBI astrometry of radio-emitting stars

    NASA Astrophysics Data System (ADS)

    Lestrade, J.-F.; Preston, R. A.; Jones, D. L.; Phillips, R. B.; Rogers, A. E. E.; Titus, M. A.; Rioja, M. J.; Gabuzda, D. C.

    1999-04-01

    Multiple-epoch phase-referenced VLBI observations of 11 radio-emitting stars have been conducted as part of an astrometric program to link the Hipparcos optical reference frame to the radio extragalactic reference frame. We present the VLBI positions, proper motions and trigonometric parallaxes from this program in the ICRF (International Celestial Reference Frame). These astrometric parameters are absolute because they are directly measured relative to the distant quasars used as VLBI phase reference calibrators. The mean astrometric precision achieved relative to the calibrators is 0.36 milliarcsecond and the highest precision is for the RS CVn close binary sigma (2) CrB with formal uncertainties of 0.12 milliarcsecond for its relative position, 0.05 milliarcsecond for its annual proper motion and 0.10 milliarcsecond for its trigonometric parallax. In addition to the Hipparcos link, these observations have provided several new results. The distance to the nearby Tau-Auriga star forming region is 148 +/- 5 pc, determined directly through the VLBI trigonometric parallax of the Pre-Main-Sequence star HD283447 of this region. The orthogonality of the 2 orbital planes in the ternary system Algol is supported by new astrometric evidences. The proper motions of HR5110, HR1099 and IM Peg, regarded as possible guide stars for the NASA Gravity Probe B space mission, have formal precisions of 0.16, 0.31 and 0.40 milliarcsecond per year, respectively, and the mission requirement is 0.15 milliarcsecond per year. The close binary UX Ari is the only star that exhibits an acceleration larger than 3sigma and the most plausible cause is the gravitational interaction of a third body. The distances of the stars HD199178, IM Peg and AR Lac were uncertain by as much as 50% before our observations and are now 116 +/- 4, 97 +/- 6, 41.7 +/- 0.6 pc, respectively. The two X-ray binaries in our program, LSI61303 and Cyg X1, exhibit larger than expected post-fit position residuals. The

  6. French Meteor Network for High Precision Orbits of Meteoroids

    NASA Technical Reports Server (NTRS)

    Atreya, P.; Vaubaillon, J.; Colas, F.; Bouley, S.; Gaillard, B.; Sauli, I.; Kwon, M. K.

    2011-01-01

    There is a lack of precise meteoroids orbit from video observations as most of the meteor stations use off-the-shelf CCD cameras. Few meteoroids orbit with precise semi-major axis are available using film photographic method. Precise orbits are necessary to compute the dust flux in the Earth s vicinity, and to estimate the ejection time of the meteoroids accurately by comparing them with the theoretical evolution model. We investigate the use of large CCD sensors to observe multi-station meteors and to compute precise orbit of these meteoroids. An ideal spatial and temporal resolution to get an accuracy to those similar of photographic plates are discussed. Various problems faced due to the use of large CCD, such as increasing the spatial and the temporal resolution at the same time and computational problems in finding the meteor position are illustrated.

  7. Radio emission from Supernovae and High Precision Astrometry

    NASA Astrophysics Data System (ADS)

    Perez-Torres, M. A.

    1999-11-01

    The present thesis work makes contributions in two scientific fronts: differential astrometry over the largest angular scales ever attempted (approx. 15 arcdegrees) and numerical simulations of radio emission from very young supernovae. In the first part, we describe the results of the use of very-long-baseline interferometry (VLBI) in one experiment designed to measure with very high precision the angular distance between the radio sources 1150+812 (QSO) and 1803+784 (BL Lac). We observed the radio sources on 19 November 1993 using an intercontinental array of radio telescopes, which simultaneously recorded at 2.3 and 8.4 GHz. VLBI differential astrometry is capable, Nature allowing, of yielding source positions with precisions well below the milliarcsecond level. To achieve this precision, we first had to accurately model the rotation of the interferometric fringes via the most precise models of Earth Orientation Parameters (EOP; precession, polar motion and UT1, nutation). With this model, we successfully connected our phase delay data at both frequencies and, using difference astrometric techniques, determined the coordinates of 1803+784 relative to those of 1150+812-within the IERS reference frame--with an standard error of about 0.6 mas in each coordinate. We then corrected for several effects including propagation medium (mainly the atmosphere and ionosphere), and opacity and source-structure effects within the radio sources. We stress that our dual-frequency measurements allowed us to accurately subtract the ionosphere contribution from our data. We also used GPS-based TEC measurements to independently find the ionosphere contribution, and showed that these contributions agree with our dual-frequency measurements within about 2 standard deviations in the less favorables cases (the longest baselines), but are usually well within one standard deviation. Our estimates of the relative positions, whether using dual-frequency-based or GPS-based ionosphere

  8. High frequency current conveyor precision full-wave rectifier

    NASA Astrophysics Data System (ADS)

    Toumazou, C.; Lidgey, F. J.; Chattong, S.

    1994-05-01

    The design of a precision full-wave rectifier using current conveyors is reported. The design uses a voltage reference circuit to clad the voltage excursions at the output of the rectifier during the zero crossings, which ensures that the usual large signal distortion associated with classical precision rectifiers is avoided. Measured rectifier performance using a 100 MHz current conveyor demonstrates good rectifier integrity at an operating frequency of 30 MHz.

  9. Ultra High Precision Laser Monitor for Oxygen Eddy Flux Measurements

    NASA Astrophysics Data System (ADS)

    Zahniser, M. S.; Nelson, D. D.; Roscioli, J. R.; Herndon, S. C.; McManus, J. B.; Jervis, D.

    2015-12-01

    Atmospheric oxygen provides one of the most powerful tracers to study the carbon cycle through its close interaction with carbon dioxide. Keeling and co-workers demonstrated this at the global scale by using small variations in atmospheric oxygen content to disentangle oceanic and terrestrial carbon sinks. It would be very exciting to apply similar ideas at the ecosystem level to improve our understanding of biosphere-atmosphere exchange and our ability to predict the response of the biosphere and atmosphere to climate change. The eddy covariance technique is perhaps the most effective approach available to quantify the exchange of gases between these spheres. Therefore, eddy covariance flux measurements of oxygen would be extremely valuable. However, this requires a fast response (0.1 seconds), high relative precision (0.001% or 10 per meg) oxygen sensor. We report recent progress in developing such a sensor using a high resolution visible laser to probe the oxygen A-band electronic transition. This sensor will enable oxygen flux measurements using eddy covariance. In addition, we will incorporate a second laser in this instrument to simultaneously determine the fluxes of oxygen, carbon dioxide and water vapor within the same sampling cell. This will provide a direct, real time measurement of the ratio of the flux of oxygen to that of carbon dioxide. This ratio is expected to vary on short time scales and small spatial scales due to the differing stoichiometry of processes producing and consuming carbon dioxide. Thus measuring the variations in the ratio of oxygen and carbon dioxide fluxes will provide mechanistic information to improve our understanding of the crucial exchange of carbon between the atmosphere and biosphere.

  10. HIGH-PRECISION ASTROMETRY WITH A DIFFRACTIVE PUPIL TELESCOPE

    SciTech Connect

    Guyon, Olivier; Eisner, Josh A.; Angel, Roger; Woolf, Neville J.; Bendek, Eduardo A.; Milster, Thomas D.; Mark Ammons, S.; Shao, Michael; Shaklan, Stuart; Levine, Marie; Nemati, Bijan; Pitman, Joe; Woodruff, Robert A.; Belikov, Ruslan

    2012-06-01

    Astrometric detection and mass determination of Earth-mass exoplanets require sub-{mu}as accuracy, which is theoretically possible with an imaging space telescope using field stars as an astrometric reference. The measurement must, however, overcome astrometric distortions, which are much larger than the photon noise limit. To address this issue, we propose to generate faint stellar diffraction spikes using a two-dimensional grid of regularly spaced small dark spots added to the surface of the primary mirror (PM). Accurate astrometric motion of the host star is obtained by comparing the position of the spikes to the background field stars. The spikes do not contribute to scattered light in the central part of the field and therefore allow unperturbed coronagraphic observation of the star's immediate surroundings. Because the diffraction spikes are created on the PM and imaged on the same focal plane detector as the background stars, astrometric distortions affect equally the diffraction spikes and the background stars and are therefore calibrated. We describe the technique, detail how the data collected by the wide-field camera are used to derive astrometric motion, and identify the main sources of astrometric error using numerical simulations and analytical derivations. We find that the 1.4 m diameter telescope, 0.3 deg{sup 2} field we adopt as a baseline design achieves 0.2 {mu}as single measurement astrometric accuracy. The diffractive pupil concept thus enables sub-{mu}as astrometry without relying on the accurate pointing, external metrology, or high-stability hardware required with previously proposed high-precision astrometry concepts.

  11. High precision metrology based microwave effective linewidth measurement technique

    SciTech Connect

    Mo, Nan; Green, Jerome J.; Beitscher, Bailey A.; Patton, Carl E.

    2007-11-15

    A precision microwave effective linewidth measurement technique for magnetic samples has been developed. The measurement utilizes a high-Q cylindrical cavity that contains the sample of interest, a highly stable and programable static magnetic field source, a computer controlled network analyzer for cavity center frequency {omega}{sub c} and quality factor Q{sub c} determinations, and the standard metrological substitution ABA method for accurate relative {omega}{sub c} and Q{sub c} measurements. Sequential long term ABA measurements show that the time and temperature drifts and random errors are the dominant sources of error, with uncertainties in {omega}{sub c}/2{pi} and Q{sub c} in the range of 50 kHz and 25, respectively. The ABA method is applied to eliminate these drifts and minimize the random errors. For measurements over 25 ABA cycles, accuracy is improved to 0.14 kHz for {omega}{sub c}/2{pi} and 3 for Q{sub c}. The temperature variation over a single ABA cycle is generally on the order of 10{sup -3}-10{sup -5} deg. C and there is no need for any further temperature stabilization or correction measures. The overall uncertainty in the 10 GHz effective linewidth determinations for a 3 mm diam, 0.5 mm thick polycrystalline yttrium iron garnet (YIG) disk is 0.15 Oe or less, well below the intrinsic single crystal YIG linewidth. This represents a factor of 10 improvement in measurement accuracy over previous work.

  12. Injector linac stability requirements for high precision experiments at MESA

    NASA Astrophysics Data System (ADS)

    Hug, F.; Heine, R.

    2017-07-01

    MESA is a recirculating superconducting accelerator under construction at Johannes Gutenberg-Universität Mainz. It will be used for high precision particle physics experiments in two different operation modes: external beam (EB) mode and energy recovery (ERL) mode. The operating beam current and energy in EB mode is 0.15 mA with polarized electrons at 155 MeV. In ERL mode an unpolarized beam of 1 mA at 105 MeV will be available. In a later construction stage of MESA the beam current in ERL-mode shall be upgraded to 10 mA. In order to achieve high beam stability and low energy spread in recirculating operation for external beam the acceleration in the main linac sections will be done on a certain phase with respect to the maximum of the accelerating field (off crest) while the return arcs provide longitudinal dispersion. On specific longitudinal working points this can result in a setting where any RF phase or magnitude jitters from main linac do not contribute to the resulting energy spread of the final beam at all. Then the resulting energy spread of the beam at the experiment is mostly determined by the beam properties provided by the injector linac. On the other hand the acceleration in ERL operation mode most likely needs to be done on crest of the accelerating field aiming for the highest efficiency in the energy recovering process albeit we are currently investigating different recirculation schemes for the ERL mode as well. Using on crest acceleration the achievable energy spread is determined by the longitudinal phase space properties behind the injector linac again but mostly by the bunch length of the beam injected to the main linac. Within this contribution we will investigate the requirements on the stability of the MESA injector linac MAMBO for achieving the experimental goals under both operating conditions.

  13. The effects of chromium complex and level on glucose metabolism and memory acquisition in rats fed high-fat diet.

    PubMed

    Sahin, Kazim; Tuzcu, Mehmet; Orhan, Cemal; Agca, Can A; Sahin, Nurhan; Guvenc, Mehmet; Krejpcio, Zbigniew; Staniek, Halina; Hayirli, Armagan

    2011-11-01

    Conditions in which glucose metabolism is impaired due to insulin resistance are associated with memory impairment. It was hypothesized that supplemental chromium (Cr) may alleviate insulin resistance in type 2 diabetes and consequently improve memory acquisition, depending upon its source and level. In a complete randomized design experiment, male Wistar rats (n=60; weighing 200-220 g) were fed either normal (8%, normal diet (ND)) or high-fat (40%, high-fat diet (HFD)) diet and supplemented with Cr as either chromium-glycinate (CrGly) or chromium-acetate (CrAc) at doses of 0, 40, or 80 μg/kg body weight (BW) via drinking water from 8 to 20 weeks of age. Feeding HFD induced type 2 diabetes, as reflected by greater glucose/insulin ratio (2.98 vs. 2.74) comparing to feeding ND. Moreover, HFD rats had greater BW (314 vs. 279 g) and less serum (53 vs. 68 μg/L) and brain (14 vs. 24 ng/g) Cr concentrations than ND rats. High-fat diet caused a 32% reduction in expressions of glucose transporters 1 and 3 (GLUTs) in brain tissue and a 27% reduction in mean percentage time spent in the target quadrant and a 38% increase in spatial memory acquisition phase (SMAP) compared with ND. Compared with supplemental Cr as CrAc, CrGly was more effective to ameliorate response variables (i.e., restoration of tissue Cr concentration, enhancement of cerebral GLUTs expressions, and reduction of the glucose/insulin ratio and SMAP) in a dose-response manner, especially in rats fed HFD. Supplemental Cr as CrGly may have therapeutic potential to enhance insulin action and alleviate memory acquisition in a dose-dependent manner, through restoring tissue Cr reserve and enhancing cerebral GLUTs expressions.

  14. Flexible high power-per-weight perovskite solar cells with chromium oxide-metal contacts for improved stability in air.

    PubMed

    Kaltenbrunner, Martin; Adam, Getachew; Głowacki, Eric Daniel; Drack, Michael; Schwödiauer, Reinhard; Leonat, Lucia; Apaydin, Dogukan Hazar; Groiss, Heiko; Scharber, Markus Clark; White, Matthew Schuette; Sariciftci, Niyazi Serdar; Bauer, Siegfried

    2015-10-01

    Photovoltaic technology requires light-absorbing materials that are highly efficient, lightweight, low cost and stable during operation. Organolead halide perovskites constitute a highly promising class of materials, but suffer limited stability under ambient conditions without heavy and costly encapsulation. Here, we report ultrathin (3 μm), highly flexible perovskite solar cells with stabilized 12% efficiency and a power-per-weight as high as 23 W g(-1). To facilitate air-stable operation, we introduce a chromium oxide-chromium interlayer that effectively protects the metal top contacts from reactions with the perovskite. The use of a transparent polymer electrode treated with dimethylsulphoxide as the bottom layer allows the deposition-from solution at low temperature-of pinhole-free perovskite films at high yield on arbitrary substrates, including thin plastic foils. These ultra-lightweight solar cells are successfully used to power aviation models. Potential future applications include unmanned aerial vehicles-from airplanes to quadcopters and weather balloons-for environmental and industrial monitoring, rescue and emergency response, and tactical security applications.

  15. Flexible high power-per-weight perovskite solar cells with chromium oxide-metal contacts for improved stability in air

    NASA Astrophysics Data System (ADS)

    Kaltenbrunner, Martin; Adam, Getachew; Głowacki, Eric Daniel; Drack, Michael; Schwödiauer, Reinhard; Leonat, Lucia; Apaydin, Dogukan Hazar; Groiss, Heiko; Scharber, Markus Clark; White, Matthew Schuette; Sariciftci, Niyazi Serdar; Bauer, Siegfried

    2015-10-01

    Photovoltaic technology requires light-absorbing materials that are highly efficient, lightweight, low cost and stable during operation. Organolead halide perovskites constitute a highly promising class of materials, but suffer limited stability under ambient conditions without heavy and costly encapsulation. Here, we report ultrathin (3 μm), highly flexible perovskite solar cells with stabilized 12% efficiency and a power-per-weight as high as 23 W g-1. To facilitate air-stable operation, we introduce a chromium oxide-chromium interlayer that effectively protects the metal top contacts from reactions with the perovskite. The use of a transparent polymer electrode treated with dimethylsulphoxide as the bottom layer allows the deposition--from solution at low temperature--of pinhole-free perovskite films at high yield on arbitrary substrates, including thin plastic foils. These ultra-lightweight solar cells are successfully used to power aviation models. Potential future applications include unmanned aerial vehicles--from airplanes to quadcopters and weather balloons--for environmental and industrial monitoring, rescue and emergency response, and tactical security applications.

  16. Precision optical slit for high heat load or ultra high vacuum

    DOEpatents

    Andresen, N.C.; DiGennaro, R.S.; Swain, T.L.

    1995-01-24

    This invention relates generally to slits used in optics that must be precisely aligned and adjusted. The optical slits of the present invention are useful in x-ray optics, x-ray beam lines, optical systems in which the entrance slit is critical for high wavelength resolution. The invention is particularly useful in ultra high vacuum systems where lubricants are difficult to use and designs which avoid the movement of metal parts against one another are important, such as monochromators for high wavelength resolution with ultra high vacuum systems. The invention further relates to optical systems in which temperature characteristics of the slit materials is important. The present invention yet additionally relates to precision slits wherein the opposing edges of the slit must be precisely moved relative to a center line between the edges with each edge retaining its parallel orientation with respect to the other edge and/or the center line. 21 figures.

  17. Precision optical slit for high heat load or ultra high vacuum

    DOEpatents

    Andresen, Nord C.; DiGennaro, Richard S.; Swain, Thomas L.

    1995-01-01

    This invention relates generally to slits used in optics that must be precisely aligned and adjusted. The optical slits of the present invention are useful in x-ray optics, x-ray beam lines, optical systems in which the entrance slit is critical for high wavelength resolution. The invention is particularly useful in ultra high vacuum systems where lubricants are difficult to use and designs which avoid the movement of metal parts against one another are important, such as monochrometers for high wavelength resolution with ultra high vacuum systems. The invention further relates to optical systems in which temperature characteristics of the slit materials is important. The present invention yet additionally relates to precision slits wherein the opposing edges of the slit must be precisely moved relative to a center line between the edges with each edge retaining its parallel orientation with respect to the other edge and/or the center line.

  18. Simultaneous Precision Gravimetry and Magnetic Gradiometry with a Bose-Einstein Condensate: A High Precision, Quantum Sensor.

    PubMed

    Hardman, K S; Everitt, P J; McDonald, G D; Manju, P; Wigley, P B; Sooriyabandara, M A; Kuhn, C C N; Debs, J E; Close, J D; Robins, N P

    2016-09-23

    A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A 5×10^{6}  atom F=1 spinor condensate of ^{87}Rb is released into free fall for up to 750 ms and probed with a T=130  ms Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states |m_{f}=1,0,-1⟩, facilitating a simultaneous measurement of the acceleration due to gravity with a 1000 run precision of Δg/g=1.45×10^{-9} and the magnetic field gradient to a precision of 120  pT/m.

  19. High-precision photometry of WASP-12 b transits

    NASA Astrophysics Data System (ADS)

    Maciejewski, G.; Errmann, R.; Raetz, St.; Seeliger, M.; Spaleniak, I.; Neuhäuser, R.

    2011-04-01

    Aims: The transiting extrasolar planet WASP-12 b was found to be one of the most intensely irradiated exoplanets. It is unexpectedly bloated and is losing mass that may accrete into the host star. Our aim was to refine the parameters of this intriguing system and search for signs of transit timing variations. Methods: We gathered high-precision light curves for two transits of WASP-12 b. Assuming various limb-darkening laws, we generated best-fitting models and redetermined the parameters of the system. Error estimates were derived by the prayer-bead method and Monte Carlo simulations. Results: System parameters obtained by us are found to agree with previous studies within one sigma. Use of the non-linear limb-darkening laws results in the best-fitting models. With two new mid-transit times, the ephemeris was refined to BJDTDB = (2 454 508.97682 ± 0.00020) + (1.09142245 ± 0.00000033)E. Interestingly, indications of transit timing variation are detected at the level of 3.4 sigma. This signal can be induced by an additional planet in the system. Simplified numerical simulations show that a perturber could be a terrestrial-type planet if both planets are in a low-order orbital resonance. However, we emphasise that further observations are needed to confirm variation and to constrain properties of the perturber. Based on observations collected at the Centro Astronómico Hispano Alemán (CAHA), operated jointly by the Max-Planck Institut für Astronomie and the Instituto de Astrofisica de Andalucia (CSIC).Photometric data are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/528/A65

  20. High Precision Prediction of Functional Sites in Protein Structures

    PubMed Central

    Buturovic, Ljubomir; Wong, Mike; Tang, Grace W.; Altman, Russ B.; Petkovic, Dragutin

    2014-01-01

    We address the problem of assigning biological function to solved protein structures. Computational tools play a critical role in identifying potential active sites and informing screening decisions for further lab analysis. A critical parameter in the practical application of computational methods is the precision, or positive predictive value. Precision measures the level of confidence the user should have in a particular computed functional assignment. Low precision annotations lead to futile laboratory investigations and waste scarce research resources. In this paper we describe an advanced version of the protein function annotation system FEATURE, which achieved 99% precision and average recall of 95% across 20 representative functional sites. The system uses a Support Vector Machine classifier operating on the microenvironment of physicochemical features around an amino acid. We also compared performance of our method with state-of-the-art sequence-level annotator Pfam in terms of precision, recall and localization. To our knowledge, no other functional site annotator has been rigorously evaluated against these key criteria. The software and predictive models are incorporated into the WebFEATURE service at http://feature.stanford.edu/wf4.0-beta. PMID:24632601

  1. Human biomonitoring of chromium and nickel from an experimental exposure to manual metal arc welding fumes of low and high alloyed steel.

    PubMed

    Bertram, Jens; Brand, Peter; Schettgen, Thomas; Lenz, Klaus; Purrio, Ellwyn; Reisgen, Uwe; Kraus, Thomas

    2015-05-01

    The uptake and elimination of metals from welding fumes is currently not fully understood. In the Aachen Workplace Simulation Laboratory (AWSL) it is possible to investigate the impact of welding fumes on human subjects under controlled exposure conditions. In this study, the uptake and elimination of chromium or chromium (VI) respectively as well as nickel was studied in subjects after exposure to the emissions of a manual metal arc welding process using low or high alloyed steel. In this present study 12 healthy male non-smokers, who never worked as welders before, were exposed for 6h to welding fumes of a manual metal arc welding process. In a three-fold crossover study design, subjects were exposed in randomized order to either clean air, emissions from welding low alloyed steel, and emissions from welding high alloyed steel. Particle mass concentration of the exposure aerosol was 2.5mg m(-3). The content of chromium and nickel in the air was determined by analysing air filter samples on a high emission scenario. Urine analysis for chromium and nickel was performed before and after exposure using methods of human biomonitoring. There were significantly elevated chromium levels after exposure to welding fumes from high alloyed steel compared to urinary chromium levels before exposure to high alloyed welding fumes, as well as compared to the other exposure scenarios. The mean values increased from 0.27 µg l(-1) to 18.62 µg l(-1). The results were in good agreement with already existing correlations between external and internal exposure (German exposure equivalent for carcinogenic working materials EKA). The variability of urinary chromium levels was high. For urinary nickel no significant changes could be detected at all. Six-hour exposure to 2.5mg m(-3) high alloyed manual metal arc welding fumes lead to elevated urinary chromium levels far higher (7.11-34.16 µg l(-1)) than the German biological exposure reference value (BAR) of 0.6 µg l(-1) directly after

  2. Studies of chromium gettering

    SciTech Connect

    Simpkins, J.E.; Mioduszewski, P.; Stratton, L.W.

    1982-01-01

    Preliminary results have shown that hydrogen pumping by chromium is a surface effect. Unlike with titanium, the getter material used in many present day tokamaks, there is no significant diffusion into the bulk. Additional experiments have been carried out to measure the basic characteristics of chromium films for gases of interest in tokamak research. These gases include deuterium, oxygen and nitrogen. A vacuum system is described which allowed precise control of the test gas, a constant wall temperature and determination of the projected getter surface area. A quadrupole mass spectrometer, rather than simply a total pressure gauge, was utilized to measure the partial pressure of the test gas as well as the residual gas composition in the system. A quartz crystal monitor was used to measure film thickness. Pumping speeds and sticking coefficients are given as a function of surface coverage for each test gas. A comparison will be made with titanium films deposited in the same vacuum system and under similar conditions.

  3. A Comparison of three high-precision quadrature schemes

    SciTech Connect

    Bailey, David H.; Li, Xiaoye S.

    2003-07-01

    The authors have implemented three numerical quadrature schemes, using the new Arbitrary Precision (ARPREC) software package, with the objective of seeking a completely ''automatic'' arbitrary precision quadrature facility, namely one that does not rely on a priori information of the function to be integrated. Such a facility is required, for example, to permit the experimental identification of definite integrals based on their numerical values. The performance and accuracy of these three quadrature schemes are compared using a suite of 15 integrals, ranging from continuous, well-behaved functions on finite intervals to functions with vertical derivatives and integrable singularities at endpoints, as well as several integrals on an infinite interval.

  4. High-Precision Coupling Mechanism Operable By Robots

    NASA Technical Reports Server (NTRS)

    Voellmer, George

    1992-01-01

    Coupling mechanism has features making it easily operable by hand and suitable for operation by robots: tolerates some initial misalignment, imposes precise final alignment, and protects itself against overtightening. Typically used to mount equipment module on structure. Mechanism includes kinematic mounts, which tolerate small initial misalignment and enforce precise final alignment as two assemblies brought together. Clamping force applied to kinematic mounts via two flexible plates. Bolt and nut tightened on flexible plates to impose spring clamping load. Repeatability of interface tested and found to be better than forty-millionths of inch.

  5. High-Precision Coupling Mechanism Operable By Robots

    NASA Technical Reports Server (NTRS)

    Voellmer, George

    1992-01-01

    Coupling mechanism has features making it easily operable by hand and suitable for operation by robots: tolerates some initial misalignment, imposes precise final alignment, and protects itself against overtightening. Typically used to mount equipment module on structure. Mechanism includes kinematic mounts, which tolerate small initial misalignment and enforce precise final alignment as two assemblies brought together. Clamping force applied to kinematic mounts via two flexible plates. Bolt and nut tightened on flexible plates to impose spring clamping load. Repeatability of interface tested and found to be better than forty-millionths of inch.

  6. High precision ages from the Torres del Paine Intrusion, Chile

    NASA Astrophysics Data System (ADS)

    Michel, J.; Baumgartner, L.; Cosca, M.; Ovtcharova, M.; Putlitz, B.; Schaltegger, U.

    2006-12-01

    The upper crustal bimodal Torres del Paine Intrusion, southern Chile, consists of the lower Paine-Mafic- Complex and the upper Paine-Granite. Geochronologically this bimodal complex is not well studied except for a few existing data from Halpern (1973) and Sanchez (2006). The aim of this study is to supplement the existing data and to constrain the age relations between the major magmatic pulses by applying high precision U-Pb dating on accessory zircons and 40Ar/39Ar-laser-step-heating-ages on biotites from the Torres del Paine Intrusion. The magmatic rocks from mafic complex are fine to medium-grained and vary in composition from quartz- monzonites to granodiorites and gabbros. Coarse-grained olivine gabbros have intruded these rocks in the west. The granitic body is represented by a peraluminous, biotite-orthoclase-granite and a more evolved leucocratic granite in the outer parts towards the host-rock. Field observations suggest a feeder-zone for the granite in the west and that the granite postdates the mafic complex. Two granite samples of the outermost margins in the Northeast and South were analyzed. The zircons were dated by precise isotope-dilution U-Pb techniques of chemically abraded single grains. The data are concordant within the analytical error and define weighted mean 206/238U ages of 12.59 ± 0.03 Ma and 12.58 ± 0.01 Ma for the two samples respectively. A 40Ar/39Ar-age for the second sample yield a date of 12.37 ± 0.11 Ma. Three 40Ar/39Ar -ages of biotites were obtained for rocks belonging to the mafic complex. A hbl-bio- granodiorite from the central part, approximately 150 m below the subhorizontal contact with the granite, gives an age of 12.81 ± 0.11 Ma. A hbl-bio-granodiorite and an olivine-gabbro west of the feeder-zone date at 12.42 ± 0.14 Ma and 12.49 ± 0.11 Ma, respectively. The obtained older age of 12.81 Ma for the granodiorite in the central part is consistent with structural relationships of brittle fracturing of the mafic

  7. Speciation, Dissolution, and Redox Reactions of Chromium Relevant to Pretreatment and Separation of High-Level Tank Wastes

    SciTech Connect

    Clark Sue B.; Dhanpat Rai; Linfeng Rao

    2005-04-20

    Chromium, one of the problematic elements in tank sludges, is considered the most important constituent in defining the total volume of high-level radioactive waste (HLW) glass. Current sludge washing processes (e.g. caustic leaching, 3 M NaOH) are not effective in removing Cr. This inefficient removal would result in production of an unacceptably large volume of HLW glass and thus a tremendous increase in the cost of waste disposal. This proposed research seeks to develop fundamental data for chromium (Cr) reactions that are not currently available but are essential for developing effective methodologies for removing Cr form high-level waste (HLW). Our objectives are to study (1) the dissolution of several solid phases (e.g., CrOOH, Cr2O3(c), Cr(OH)3, and Fe and Cr, binary hydroxides, identified to be important from sludge leaching studies) in highly alkaline solutions and in the presence of other electrolytes (e.g., carbonate, phosphate, sulfate, nitrite), and (2) the effect of the nature of Cr solid phases and aqueous species on their redox reactivity with a variety of potential oxidants (e.g., H2o2, persulfate, O2, and ferrate). This information will provide critical support for developing enhanced pretreatment strategies for removing Cr from HLW and will achieve a major cost reduction HLW disposal.

  8. Speciation, Dissolution, and Redox Reactions of Chromium Relevant to Pretreatment and Separation of High-Level Tank Wastes

    SciTech Connect

    Rai Dhanpat; Rao Linfeng

    2005-09-30

    Chromium, one of the problematic elements in tank sludges, is considered the most important constituent in defining the total volume of high-level radioactive waste (HLW) glass. Current sludge washing processes (e.g. caustic leaching, 3 M NaOH) are not effective in removing Cr. Such inefficient removal would result in the production of an unacceptably large volume of HLW glass and thus a tremendous increase in the cost of waste disposal. This proposed research seeks to develop fundamental data for chromium (Cr) reactions that are not currently available but are essential for developing effective methodologies for removing Cr form high-level waste (HLW). Our objectives are to study (1) the dissolution of several solid phases (e.g., CrOOH, Cr2O3(c), Cr(OH)3, and Fe and Cr, binary hydroxides, identified to be important from sludge leaching studies) in highly alkaline solutions and in the presence of other electrolytes (e.g., carbonate, phosphate, sulfate, nitrite), and (2) the effect of the nature of Cr solid phases and aqueous species on their redox reactivity with a variety of potential oxidants (H2O2, persulfate, hypochlorite, etc.). This information will provide critical support for developing enhanced pretreatment strategies for removing Cr from HLW and will achieve a major cost reduction in HLW disposal.

  9. CUSB-II: a high precision electromagnetic spectrometer

    NASA Astrophysics Data System (ADS)

    Schamberger, R. D.; Heintz, U.; Lee-Franzini, J.; Lovelock, D. M. J.; Narain, M.; Willins, J.; Yanagisawa, C.; Tuts, P. M.; Franzini, P.; Kanekal, S.; Wu, Q. W.

    1991-11-01

    The design, construction and performance of a very compact precision electromagnetic spectrometer is described. The CUSB-II detector has been used to study ϒ spectroscopy, search for exotic particles and measure properties of the B and B ∗ mesons at the Cornell Electron Storage Ring.

  10. High-precision Stellar Limb-darkening in Exoplanetary Transits

    NASA Astrophysics Data System (ADS)

    Morello, G.; Tsiaras, A.; Howarth, I. D.; Homeier, D.

    2017-09-01

    Characterization of the atmospheres of transiting exoplanets relies on accurate measurements of the extent of the optically thick area of the planet at multiple wavelengths with a precision ≲ 100 parts per million (ppm). Next-generation instruments onboard the James Webb Space Telescope (JWST) are expected to achieve ∼10 ppm precision for several tens of targets. A similar precision can be obtained in modeling only if other astrophysical effects, including the stellar limb-darkening, are properly accounted for. In this paper, we explore the limits on precision due to the mathematical formulas currently adopted to approximate the stellar limb-darkening, and due to the use of limb-darkening coefficients obtained either from stellar-atmosphere models or empirically. We recommend the use of a two-coefficient limb-darkening law, named “power-2,” which outperforms other two-coefficient laws adopted in the exoplanet literature in most cases, and particularly for cool stars. Empirical limb-darkening based on two-coefficient formulas can be significantly biased, even if the light-curve residuals are nearly photon-noise limited. We demonstrate an optimal strategy to fitting for the four-coefficient limb-darkening in the visible, using prior information on the exoplanet orbital parameters to break some of the degeneracies that otherwise would prevent the convergence of the fit. Infrared observations taken with the JWST will provide accurate measurements of the exoplanet orbital parameters with unprecedented precision, which can be used as priors to improve the stellar limb-darkening characterization, and therefore the inferred exoplanet parameters, from observations in the visible, such as those taken with Kepler/K2, the JWST, and other past and future instruments.

  11. Development of analytical procedures for determination of total chromium by quadrupole ICP-MS and high-resolution ICP-MS, and hexavalent chromium by HPLC-ICP-MS, in different materials used in the automotive industry.

    PubMed

    Séby, F; Gagean, M; Garraud, H; Castetbon, A; Donard, O F X

    2003-10-01

    A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP-MS). High resolution (HR) ICP-MS was used to examine the influence of polyatomic interferences on the detection of the (52)Cr(+) and (53)Cr(+) isotopes. If there was strong interference with m/ z 52 for plastic materials, it was possible to use quadrupole ICP-MS for m/ z 53 if digestions were performed with HNO(3)+H(2)O(2). This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH(4)(+)/NH(3) buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC-ICP-MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc-nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient

  12. Stabilized chromium oxide film

    DOEpatents

    Garwin, Edward L.; Nyaiesh, Ali R.

    1988-01-01

    Stabilized air-oxidized chromium films deposited on high-power klystron ceramic windows and sleeves having a thickness between 20 and 150.ANG. are useful in lowering secondary electron emission yield and in avoiding multipactoring and window failure due to overheating. The ceramic substrate for the film is chosen from alumina, sapphire or beryllium oxide.

  13. Stabilized chromium oxide film

    DOEpatents

    Nyaiesh, A.R.; Garwin, E.L.

    1986-08-04

    Stabilized air-oxidized chromium films deposited on high-power klystron ceramic windows and sleeves having a thickness between 20 and 150A are useful in lowering secondary electron emission yield and in avoiding multipactoring and window failure due to overheating. The ceramic substrate for the film is chosen from alumina, sapphire or beryllium oxide.

  14. Preliminary design approach for large high precision segmented reflectors

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin M., Jr.; Collins, Timothy J.; Hedgepeth, John M.

    1990-01-01

    A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.

  15. Joint Estimation of Multiple High-dimensional Precision Matrices

    PubMed Central

    Cai, T. Tony; Li, Hongzhe; Liu, Weidong; Xie, Jichun

    2017-01-01

    Motivated by analysis of gene expression data measured in different tissues or disease states, we consider joint estimation of multiple precision matrices to effectively utilize the partially shared graphical structures of the corresponding graphs. The procedure is based on a weighted constrained ℓ∞/ℓ1 minimization, which can be effectively implemented by a second-order cone programming. Compared to separate estimation methods, the proposed joint estimation method leads to estimators converging to the true precision matrices faster. Under certain regularity conditions, the proposed procedure leads to an exact graph structure recovery with a probability tending to 1. Simulation studies show that the proposed joint estimation methods outperform other methods in graph structure recovery. The method is illustrated through an analysis of an ovarian cancer gene expression data. The results indicate that the patients with poor prognostic subtype lack some important links among the genes in the apoptosis pathway.

  16. Nickel and chromium isotopes in Allende inclusions

    NASA Astrophysics Data System (ADS)

    Birck, J. L.; Lugmair, G. W.

    1988-10-01

    High-precision nickel and chromium isotopic measurements were carried out on nine Allende inclusions. It is found that Ni-62, Ni-64, excesses are present in at least three of the samples. The results suggest that the most likely mechanism for the anomalies is a neutron-rich statistical equilibrium process. An indication of elevated Ni-60 is found in almost every inclusion measured. This effect is thought to be related to the decay of now extinct Fe-60. An upper limit of 1.6 X 10 to the -6th is calculated for the Fe-60/Fe-56 ratio at the time these Allende inclusions crystallized.

  17. Nickel and chromium isotopes in Allende inclusions

    NASA Technical Reports Server (NTRS)

    Birck, J. L.; Lugmair, G. W.

    1988-01-01

    High-precision nickel and chromium isotopic measurements were carried out on nine Allende inclusions. It is found that Ni-62, Ni-64, excesses are present in at least three of the samples. The results suggest that the most likely mechanism for the anomalies is a neutron-rich statistical equilibrium process. An indication of elevated Ni-60 is found in almost every inclusion measured. This effect is thought to be related to the decay of now extinct Fe-60. An upper limit of 1.6 X 10 to the -6th is calculated for the Fe-60/Fe-56 ratio at the time these Allende inclusions crystallized.

  18. Nickel and chromium isotopes in Allende inclusions

    NASA Technical Reports Server (NTRS)

    Birck, J. L.; Lugmair, G. W.

    1988-01-01

    High-precision nickel and chromium isotopic measurements were carried out on nine Allende inclusions. It is found that Ni-62, Ni-64, excesses are present in at least three of the samples. The results suggest that the most likely mechanism for the anomalies is a neutron-rich statistical equilibrium process. An indication of elevated Ni-60 is found in almost every inclusion measured. This effect is thought to be related to the decay of now extinct Fe-60. An upper limit of 1.6 X 10 to the -6th is calculated for the Fe-60/Fe-56 ratio at the time these Allende inclusions crystallized.

  19. Ion source for high-precision mass spectrometry

    DOEpatents

    Todd, Peter J.; McKown, Henry S.; Smith, David H.

    1984-01-01

    The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit.

  20. High-precision dynamic orbit integration for spaceborne gravimetry

    NASA Astrophysics Data System (ADS)

    Ellmer, M.; Mayer-Gürr, T.

    2016-12-01

    Future gravity missions like GRACE Follow-On and beyond will deliver low-low satellite-to-satellite ranging measurements of much increased precision. To prepare for the new challenges and opportunities involved in processing this new data, it is necessary to perform a systematic review and re-evaluation of current algorithms and assumptions used in gravity field determination from GRACE data. In this context, this study investigates the computation of dynamic orbits from GRACE accelerometer measurements and background models, which are used at multiple steps in gravity recovery. They are, for example, used in computing linearised observation equations for the low-low satellite-to-satellite tracking instruments, or to evaluate potential models like static fields or dealiasing products. It is thus desirable for the precision at which the dynamic orbits are determined to surpass the precision of the ranging observations. We computed dynamic orbits for GRACE, both in a simple simulation and for real observational data. We observed the differences between successive iterations of orbit determination and used these as a benchmark for the quality of the orbit solution. We implemented a numerically stable orbit determination algorithm employing Encke's method, in which we use a novel reference trajectory determined through rigorous optimization. This reference trajectory was parameterised and computed using equinoctial elements to minimize orbit errors resulting from imprecision in the reference motion. We present the effects of these two optimizations on the dynamic orbits, and show that the resulting orbits are self-consistent to below the expected precision of the GRACE Follow-On ranging instruments.

  1. Ion source for high-precision mass spectrometry

    DOEpatents

    Todd, P.J.; McKown, H.S.; Smith, D.H.

    1982-04-26

    The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit. 2 figures, 3 tables.

  2. Yale High Energy Physics Research: Precision Studies of Reactor Antineutrinos

    SciTech Connect

    Heeger, Karsten M.

    2014-09-13

    This report presents experimental research at the intensity frontier of particle physics with particular focus on the study of reactor antineutrinos and the precision measurement of neutrino oscillations. The experimental neutrino physics group of Professor Heeger and Senior Scientist Band at Yale University has had leading responsibilities in the construction and operation of the Daya Bay Reactor Antineutrino Experiment and made critical contributions to the discovery of non-zero$\\theta_{13}$. Heeger and Band led the Daya Bay detector management team and are now overseeing the operations of the antineutrino detectors. Postdoctoral researchers and students in this group have made leading contributions to the Daya Bay analysis including the prediction of the reactor antineutrino flux and spectrum, the analysis of the oscillation signal, and the precision determination of the target mass yielding unprecedented precision in the relative detector uncertainty. Heeger's group is now leading an R\\&D effort towards a short-baseline oscillation experiment, called PROSPECT, at a US research reactor and the development of antineutrino detectors with advanced background discrimination.

  3. Gauges for Highly Precise Metrology of a Compound Mirror

    NASA Technical Reports Server (NTRS)

    Gursel, Yekta

    2005-01-01

    Three optical gauges have been developed for guiding the assembly and measuring precisely the reflecting surfaces of a compound mirror that comprises a corner-cube retroreflector glued in a hole on a flat mirror. In the specific application for which the gauges were developed, the compound mirror is part of a siderostat in a stellar interferometer. The flat-mirror portion of the compound mirror is the siderostat mirror; the retroreflector portion of the compound mirror is to be used, during operation of the interferometer, to monitor the location of the siderostat mirror surface relative to other optical surfaces of the interferometer. Nominally, the optical corner of the retroreflector should lie precisely on the siderostat mirror surface, but this precision cannot be achieved in fabrication: in practice, there remains some distance between the optical corner and the siderostat mirror surface. For proper operation of the interferometer, it is required to make this distance as small as possible and to know this distance within 1 nm. The three gauges make it possible to satisfy these requirements.

  4. High-capacity adsorption of dissolved hexavalent chromium using amine-functionalized magnetic corn stalk composites.

    PubMed

    Song, Wen; Gao, Baoyu; Zhang, Tengge; Xu, Xing; Huang, Xin; Yu, Huan; Yue, Qinyan

    2015-08-01

    Easily separable amine-functionalized magnetic corn stalk composites (AF-MCS) were employed for effective adsorption and reduction of toxic hexavalent chromium [Cr(VI)] to nontoxic Cr(III). The saturated magnetization of AF-MCS reached 6.2emu/g, and as a result, it could be separated from aqueous solution by a magnetic process for its superparamagnetism. The studies of various factors influencing the sorption behavior indicated that the optimum AF-MCS dosage for Cr(VI) adsorption was 1g/L, and the maximum adsorption capacity was observed at pH 3.0. The chromium adsorption perfectly fitted the Langmuir isotherm model and pseudo second order kinetic model. Furthermore, characterization of AF-MCS was investigated by means of XRD, SEM, TEM, FT-IR, BET, VSM and XPS analysis to discuss the uptake mechanism. Basically, these results demonstrated that AF-MCS prepared in this work has shown its merit in effective removal of Cr(VI) and rapid separation from effluents simultaneously.

  5. Influence of pH on the survival of Dictyosphaerium chlorelloides populations living in aquatic environments highly contaminated with chromium.

    PubMed

    Pereira, María; Bartolomé, M Carmen; Sánchez-Fortún, Sebastián

    2013-12-01

    The accommodation of photosynthetic organisms to adverse conditions, such as pH changes in the aquatic environment, and their response to aquatic pollutants is essential to develop future biosensors. The present study reports the ability of both Cr(VI)-sensitive and tolerant Dyctiosphaerium chlorelloides strains to live in aqueous solutions highly contaminated with hexavalent chromium under varying ranges of pH, by the determination of chromium toxic effects on these strains. Studies of cell growth, photosynthetic quantum yield and gross photosynthesis rate show that both D. chlorelloides strains are able to survive in alkaline and moderately acidified (pH 4.25) aquatic environments. Below this pH value cell populations from both strains exposed for short periods of time to Cr(VI) showed alterations in the three parameters studied. There were no significant differences comparing the response of both strains at pH change in the culture medium. However, Cr(VI)-tolerant strain exhibits a better fit to maintain cell growth than Cr(VI)-sensitive strain when both were subjected to pH 4.25 in the culture medium. The absence of significant differences in photosynthetic activity results for both strains suggests that the lower sensitivity exhibited by Cr(VI)-tolerant strain would be due to cellular morphological changes rather than changes in cellular activity. © 2013 Published by Elsevier Inc.

  6. Effect of Chromium on Corrosion Behavior of P110 Steels in CO2-H2S Environment with High Pressure and High Temperature

    PubMed Central

    Sun, Jianbo; Sun, Chong; Lin, Xueqiang; Cheng, Xiangkun; Liu, Huifeng

    2016-01-01

    The novel Cr-containing low alloy steels have exhibited good corrosion resistance in CO2 environment, mainly owing to the formation of Cr-enriched corrosion film. In order to evaluate whether it is applicable to the CO2 and H2S coexistence conditions, the corrosion behavior of low-chromium steels in CO2-H2S environment with high pressure and high temperature was investigated using weight loss measurement and surface characterization. The results showed that P110 steel suffered localized corrosion and both 3Cr-P110 and 5Cr-P110 steels exhibited general corrosion. However, the corrosion rate of 5Cr-P110 was the highest among them. The corrosion process of the steels was simultaneously governed by CO2 and H2S. The outer scales on the three steels mainly consisted of FeS1−x crystals, whereas the inner scales on Cr-containing steels comprised of amorphous FeS1−x, Cr(OH)3 and FeCO3, in contrast with the amorphous FeS1−x and FeCO3 mixture film of P110 steel. The more chromium the steel contains, the more chromium compounds the corrosion products contain. The addition of chromium in steels increases the uniformity of the Cr-enriched corrosion scales, eliminates the localized corrosion, but cannot decrease the general corrosion rates. The formation of FeS1−x may interfere with Cr-enriched corrosion scales and lowering the corrosion performance of 3Cr-P110 and 5Cr-P110 steels. PMID:28773328

  7. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.

    PubMed

    Vendittoli, P-A; Mottard, S; Roy, A G; Dupont, C; Lavigne, M

    2007-04-01

    We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 microg/L (0.4 to 5.5) for chromium and 0.67 microg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female gender and the inclination of the acetabular component were inversely proportional to the values of chromium and/or cobalt ions at one year postoperatively. Other factors, such as age and level of activity, did not correlate with the levels of metal ions. We found that the levels of the ions in the serum were 1.39 and 1.37 times higher for chromium and cobalt respectively than those in the whole blood. The levels of metal ions obtained may be specific to the hip resurfacing implant and reflect its manufacturing process.

  8. Highly active chromium-based selective ethylene tri-/tetramerization catalysts supported by PNPO phosphazane ligands.

    PubMed

    Zhou, Yusheng; Wu, Hongfei; Xu, Sheng; Zhang, Xuejun; Shi, Min; Zhang, Jun

    2015-05-28

    Novel Cr(iii) catalysts supported by PNPO phosphazane ligands of the type Ph2PN(R)P(Ph)OAr have been prepared, all of which, upon activation with MMAO-3A, are highly active in ethylene tri-/tetramerization with considerable selectivity. The effect of ligand substitution on the catalytic performance has been examined. The Cr precatalyst supported by the PNPO phosphazane ligand with an N-cyclohexyl achieved high activity of 316.7 kg (g Cr h(-1))(-1) and a high total selectivity of 85.1% towards valuable 1-hexene (45.7%) and 1-octene (39.4%) using chlorobenzene as the solvent at 35 bar and 40 °C. In methylcyclohexane, the precatalyst supported by [Ph2PN((i)Pr)P(Ph)OPh] exhibited a higher 1-octene selectivity (54.0%) with a considerable activity of 73.3 kg (g Cr h(-1))(-1) at 35 bar and 40 °C. With the fine-tuned ligand backbone, such a PNPO phosphazane-based catalyst system provides a mode for precise understanding of the impact of ligand variations on catalytic performance.

  9. Visual Inspection of Machined Metallic High-Precision Surfaces

    NASA Astrophysics Data System (ADS)

    Pernkopf, Franz; O'Leary, Paul

    2002-12-01

    This paper presents a surface inspection prototype of an automatic system for precision ground metallic surfaces, in this case bearing rolls. The surface reflectance properties are modeled and verified with optical experiments. The aim being to determine the optical arrangement for illumination and observation, where the contrast between errors and intact surface is maximized. A new adaptive threshold selection algorithm for segmentation is presented. Additionally, is included an evaluation of a large number of published sequential search algorithms for selection of the best subset of features for the classification with a comparison of their computational requirements. Finally, the results of classification for 540 flaw images are presented.

  10. High Precision Material Study at Near Millimeter Wavelengths.

    DTIC Science & Technology

    1983-08-30

    Laser, Rexolite, TPX , Dynasil 4000. LQj .~4 20.1 ABSR*ACT ’Cath- do -- e8e11110 if nmwe*my selIdenti by block n"Whe") ’-2 Various quasi-optical...pyroelectric detectors (Laser Precision Rkp-545): L L, and L TPx lens; BS1, wire-mesh beam splitter; BS, mylar-film beam splitter; DPC, double-prism coupler...focused at the entrance to the guide with a waist radius of approximately 0.6435a, where a is the radius of the guide. A lens made from TPX plastic was

  11. Studies of chromium gettering

    NASA Astrophysics Data System (ADS)

    Simpkins, J. E.; Mioduszewski, P.; Stratton, L. W.

    1982-12-01

    Preliminary results have shown that hydrogen pumping by chromium is a surface effect. Unlike with titanium, the getter material used in many present day tokamaks, there is no significant diffusion into the bulk. This feature, which would minimize the tritium inventory, makes chromium a viable alternate to titanium gettering for future tokamaks. Additional experiments have been carried out to measure the basic characteristics of chromium films for gases of interest in tokamak research. These gases include deuterium, oxygen and nitrogen. A vacuum system is described which allowed precise control of the test gas, a constant wall temperature and determination of the projected getter surface area. A quadrupole mass spectrometer, rather than simply a total pressure gauge, was utilized to measure the partial pressure of the test gas as well as the residual gas composition in the system. A quartz crystal monitor was used to measure film thickness. Pumping speeds and sticking coefficients are given as a function of surface coverage for each test gas. A comparison will be made with titanium films deposited in the same vacuum system and under similar conditions.

  12. High cycle fatigue life improvement of polycrystalline alpha-iron modified by silver, chromium, aluminium, and yttrium ion implantation

    SciTech Connect

    Wang, H.W.; Yang, D.Z.; Shi, W.D.; Patu, S.

    1995-06-15

    Body-centered cubic (bcc) metals are at least of parallel significance to fcc ones. Work on bcc metal`s fatigue modification by ion implantation is rare. The asymmetry deformation and high SFE characteristics in the microplasticity of bcc metals make the fatigue process more complex. The authors have chosen polycrystalline alpha-iron as the target metal to be implanted with silver, chromium, aluminium, and yttrium ions, which are mutually immiscible, limited soluble without precipitation, and soluble with precipitation in iron, respectively. This work aims at providing a systematic investigation on different mechanisms dominant in fatigue. This brief report is on the high cycle fatigue (HCF) property improvement by these metallic ion implantations, which is part of a series of reports both on HCF and low cycle fatigue (LCF) modifications by each individual ion implantation.

  13. High precision high voltage divider and its application to electron beam ion traps

    SciTech Connect

    Chen, W. D.; Xiao, J.; Shen, Y.; Fu, Y. Q.; Meng, F. C.; Chen, C. Y.; Zou, Y.; Hutton, R.

    2008-12-15

    A high precision high voltage divider has been developed for the electron beam ion trap in Shanghai. The uncertainty caused by the temperature coefficient of resistance (TCR) and the voltage coefficient of resistance has been studied in detail and was minimized to the level of ppm (10{sup -6}) range. Once the TCR was matched between the resistors, the precision of the dividing ratio finally reached the ppm range also. We measured the delay of the divider caused by the capacitor introduced to minimize voltage ripple to be 2.35 ms. Finally we applied the divider to an experiment to measure resonant energies for some dielectronic recombination processes for highly charged xenon ions. The final energies include corrections for both space charge and fringe field effects are mostly under 0.03%.

  14. A high precision, compact electromechanical ground rotation sensor

    SciTech Connect

    Dergachev, V.; DeSalvo, R.; Asadoor, M.; Bhawal, A.; Gong, P.; Kim, C.; Lottarini, A.; Minenkov, Y.; Murphy, C.; O'Toole, A.; Peña Arellano, F. E.; and others

    2014-05-15

    We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of 1 × 10{sup −11}m/√( Hz ). We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of 5.7 × 10{sup −9} rad /√( Hz ) at 10 mHz and 6.4 × 10{sup −10} rad /√( Hz ) at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

  15. Decade-Spanning High-Precision Terahertz Frequency Comb

    NASA Astrophysics Data System (ADS)

    Finneran, Ian A.; Good, Jacob T.; Holland, Daniel B.; Carroll, P. Brandon; Allodi, Marco A.; Blake, Geoffrey A.

    2015-04-01

    The generation and detection of a decade-spanning terahertz (THz) frequency comb is reported using two Ti:sapphire femtosecond laser oscillators and asynchronous optical sampling THz time-domain spectroscopy. The comb extends from 0.15 to 2.4 THz, with a tooth spacing of 80 MHz, a linewidth of 3.7 kHz, and a fractional precision of 1.8 ×10-9 . With time-domain detection of the comb, we measure three transitions of water vapor at 10 mTorr between 1-2 THz with an average Doppler-limited fractional accuracy of 6.1 ×10-8 . Significant improvements in bandwidth, resolution, and sensitivity are possible with existing technologies.

  16. A high precision, compact electromechanical ground rotation sensor.

    PubMed

    Dergachev, V; DeSalvo, R; Asadoor, M; Bhawal, A; Gong, P; Kim, C; Lottarini, A; Minenkov, Y; Murphy, C; O'Toole, A; Peña Arellano, F E; Rodionov, A V; Shaner, M; Sobacchi, E

    2014-05-01

    We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of 1 × 10⁻¹¹ m/√Hz. We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of 5.7 × 10⁻⁹ rad/√Hz at 10 mHz and 6.4 × 10⁻¹⁰ rad/√Hz at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

  17. Aerospace Laser Ignition/Ablation Variable High Precision Thruster

    NASA Technical Reports Server (NTRS)

    Campbell, Jonathan W. (Inventor); Edwards, David L. (Inventor); Campbell, Jason J. (Inventor)

    2015-01-01

    A laser ignition/ablation propulsion system that captures the advantages of both liquid and solid propulsion. A reel system is used to move a propellant tape containing a plurality of propellant material targets through an ignition chamber. When a propellant target is in the ignition chamber, a laser beam from a laser positioned above the ignition chamber strikes the propellant target, igniting the propellant material and resulting in a thrust impulse. The propellant tape is advanced, carrying another propellant target into the ignition chamber. The propellant tape and ignition chamber are designed to ensure that each ignition event is isolated from the remaining propellant targets. Thrust and specific impulse may by precisely controlled by varying the synchronized propellant tape/laser speed. The laser ignition/ablation propulsion system may be scaled for use in small and large applications.

  18. Decade-spanning high-precision terahertz frequency comb.

    PubMed

    Finneran, Ian A; Good, Jacob T; Holland, Daniel B; Carroll, P Brandon; Allodi, Marco A; Blake, Geoffrey A

    2015-04-24

    The generation and detection of a decade-spanning terahertz (THz) frequency comb is reported using two Ti:sapphire femtosecond laser oscillators and asynchronous optical sampling THz time-domain spectroscopy. The comb extends from 0.15 to 2.4 THz, with a tooth spacing of 80 MHz, a linewidth of 3.7 kHz, and a fractional precision of 1.8×10^{-9}. With time-domain detection of the comb, we measure three transitions of water vapor at 10 mTorr between 1-2 THz with an average Doppler-limited fractional accuracy of 6.1×10^{-8}. Significant improvements in bandwidth, resolution, and sensitivity are possible with existing technologies.

  19. A high precision, compact electromechanical ground rotation sensor

    NASA Astrophysics Data System (ADS)

    Dergachev, V.; DeSalvo, R.; Asadoor, M.; Bhawal, A.; Gong, P.; Kim, C.; Lottarini, A.; Minenkov, Y.; Murphy, C.; O'Toole, A.; Peña Arellano, F. E.; Rodionov, A. V.; Shaner, M.; Sobacchi, E.

    2014-05-01

    We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of {1}{ × 10^{-11}}textrm { m}/sqrt{textrm {Hz}}. We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of {5.7}{ × 10^{-9}}textrm { rad}/sqrt{textrm {Hz}} at 10 mHz and {6.4}{ × 10^{-10}}textrm { rad}/sqrt{textrm {Hz}} at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

  20. HIGH-PRECISION DYNAMICAL MASSES OF VERY LOW MASS BINARIES

    SciTech Connect

    Konopacky, Q. M.; Ghez, A. M.; McLean, I. S.; Barman, T. S.; Rice, E. L.; Bailey, J. I.; White, R. J.; Duchene, G. E-mail: ghez@astro.ucla.ed E-mail: barman@lowell.ed E-mail: white@chara.gsu.ed

    2010-03-10

    We present the results of a three year monitoring program of a sample of very low mass (VLM) field binaries using both astrometric and spectroscopic data obtained in conjunction with the laser guide star adaptive optics system on the W. M. Keck II 10 m telescope. Among the 24 systems studied, 15 have undergone sufficient orbital motion, allowing us to derive their relative orbital parameters and hence their total system mass. These measurements more than double the number of mass measurements for VLM objects, and include the most precise mass measurement to date (<2%). Among the 11 systems with both astrometric and spectroscopic measurements, six have sufficient radial velocity variations to allow us to obtain individual component masses. This is the first derivation of the component masses for five of these systems. Altogether, the orbital solutions of these low mass systems show a correlation between eccentricity and orbital period, consistent with their higher mass counterparts. In our primary analysis, we find that there are systematic discrepancies between our dynamical mass measurements and the predictions of theoretical evolutionary models (TUCSON and LYON) with both models either underpredicting or overpredicting the most precisely determined dynamical masses. These discrepancies are a function of spectral type, with late-M through mid-L systems tending to have their masses underpredicted, while one T-type system has its mass overpredicted. These discrepancies imply that either the temperatures predicted by evolutionary and atmosphere models are inconsistent for an object of a given mass, or the mass-radius relationship or cooling timescales predicted by the evolutionary models are incorrect. If these spectral-type trends are correct and hold into the planetary mass regime, the implication is that the masses of directly imaged extrasolar planets are overpredicted by the evolutionary models.

  1. Study on manufacturing method of optical surface with high precision in angle and surface

    NASA Astrophysics Data System (ADS)

    Yu, Xin; Li, Xin; Yu, Ze; Zhao, Bin; Zhang, Xuebin; Sun, Lipeng; Tong, Yi

    2016-10-01

    This paper studied a manufacturing processing of optical surface with high precision in angel and surface. By theoretical analysis of the relationships between the angel precision and surface, the measurement conversion of the technical indicators, optical-cement method application, the optical-cement tooling design, the experiment has been finished successfully, the processing method has been verified, which can be also used in the manufacturing of the optical surface with similar high precision in angle and surface.

  2. High glucose and ketosis (acetoacetate) increases, and chromium niacinate decreases, IL-6, IL-8, and MCP-1 secretion and oxidative stress in U937 monocytes.

    PubMed

    Jain, Sushil K; Rains, Justin L; Croad, Jennifer L

    2007-10-01

    Elevated blood levels of the proinflammatory cytokines interleukin-6 (IL-6), interleukin-8 (IL-8), and MCP-1 (monocyte chemoattractant protein-1) increase insulin resistance and the risk of cardiovascular disease (CVD). There is no previous study that has examined the effect of ketosis and trivalent chromium on IL-6, IL-8, or MCP-1 secretion in any cell type or in human or animal model. The authors examined the hypothesis that ketosis increases and trivalent chromium decreases the levels of cytokines and oxidative stress in diabetes using a U937 monocyte cell culture model. Cells were cultured with control, high glucose (HG), and acetoacetate (AA) in the absence or presence (0.5-10 microM) of CrCl(3), chromium picolinate (Cr-P), or chromium niacinate (Cr-N) at 37 degrees C for 24 h. The data show a significant stimulation of IL-6, IL-8, and MCP-1 secretion and an increase in oxidative stress in cells treated with HG or AA. The effect of HG on cytokine secretion was reduced by Cr-N, and to a lesser extent by CrCl(3) and Cr-P. The effect of HG on oxidative stress was reduced by Cr-N and CrCl 3, but not by Cr-P. Similarly, Cr-N decreased the cytokine secretion in HG + AA-treated cells. Cr-N significantly decreased standard oxidant (H(2)O(2)) induced cytokine secretion, which suggests that reduction of cytokine secretion by Cr-N is in part mediated by its antioxidative effect. In a cell culture model, Cr-N appears to be the most effective form of chromium in inhibiting oxidative stress and proinflammatory cytokine secretion by monocytes. This study suggests that chromium niacinate supplementation may be useful in reducing vascular inflammation and the risk of CVD in diabetes.

  3. Effect of prior deformation on microstructural development and Laves phase precipitation in high-chromium stainless steel.

    PubMed

    Hsiao, Z-W; Chen, D; Kuo, J-C; Lin, D-Y

    2017-04-01

    This study investigated the influence of deformation on precipitation behaviour and microstructure change during annealing. Here, the prior deformation of high-chromium stainless steel was tensile deformation of 3%, 6% and 10%, and the specimens were then annealed at 700˚C for 10 h. The specimens were subsequently analyzed using backscattered electron image and electron backscattering diffraction measurements with SEM. Compared with the deformation microstructure, the grains revealed no preferred orientation. The precipitates of TiN and NbC were formed homogenously in the grain interior and at grain boundaries after annealing. Fine Laves phase precipitates were observed in grains and along subgrain boundaries as the deformation increased. Furthermore, the volume fraction of Laves phase increased, but the average particle diameter of precipitate was reduced as the deformation increased.

  4. Studies on the characterization and tribological behavior of self-propagating high-temperature synthesis (SHS) coatings of chromium cermet

    SciTech Connect

    Li, L.; Qunji, X.

    1996-12-31

    A chromium cermet coating, about 150 {micro}m thick, was formed on carbon steel with the gas transport self-propagating high-temperature synthesis (SHS) coating process. The present paper is concerned with the preparation method, property evaluation, and abrasive wear behavior of the SHS coatings. The experiment reveals that there is excellent adhesion between the coating and the substrate, with less matrix damage and good abrasive wear resistance compared with chemical vapor deposition (CVD)-Cr{sub 7}C{sub 3} coatings. Investigations indicated that an intense metallurgical interaction, gradient composition distribution, and unique forming process are the major reasons for the superior performance of the SHS coatings. It is analytically shown that there is a relationship between the size of the abrasive, the coating thickness, and the abrasive wear resistance.

  5. High precision (14 bit), high density (octal) analog to digital converter for spectroscopy applications

    NASA Astrophysics Data System (ADS)

    Subramaniam, E. T.; Jain, Mamta; Bhowmik, R. K.; Tripon, Michel

    2008-10-01

    Nuclear and particle physics experiments with large number of detectors require signal processing and data collection strategies that call for the ability to collect large amount of data while not sacrificing the precision and accuracy of the data being collected. This paper deals with the development of a high precision pulse peak detection, analog to digital converter (ADC) module with eight independent channels in plug-in daughter card motherboard model, best suited for spectroscopy experiments. This module provides multiple channels without cross-talk and of 14 bit resolution, while maintaining high density (each daughter card has an area of just 4.2″×0.51″) and exhibiting excellent integral nonlinearity (≤±2 mV or ±0.02% full scale reading) and differential nonlinearity (≤±1%). It was designed, developed and tested, in house, and gives added advantages of cost effectiveness and ease of maintenance.

  6. High precision (14 bit), high density (octal) analog to digital converter for spectroscopy applications.

    PubMed

    Subramaniam, E T; Jain, Mamta; Bhowmik, R K; Tripon, Michel

    2008-10-01

    Nuclear and particle physics experiments with large number of detectors require signal processing and data collection strategies that call for the ability to collect large amount of data while not sacrificing the precision and accuracy of the data being collected. This paper deals with the development of a high precision pulse peak detection, analog to digital converter (ADC) module with eight independent channels in plug-in daughter card motherboard model, best suited for spectroscopy experiments. This module provides multiple channels without cross-talk and of 14 bit resolution, while maintaining high density (each daughter card has an area of just 4.2(")x0.51(")) and exhibiting excellent integral nonlinearity (< or = +/-2 mV or +/-0.02% full scale reading) and differential nonlinearity (< or = +/-1%). It was designed, developed and tested, in house, and gives added advantages of cost effectiveness and ease of maintenance.

  7. High-precision atomic structure measurements in thallium

    NASA Astrophysics Data System (ADS)

    Burkhardt, M. H.; Holmes, C. D.; Uhl, R.; Majumder, P. K.

    2004-05-01

    Using a thallium atomic beam apparatus, we are undertaking a series of laser spectroscopy measurements with the goal of providing precise, independent cross-checks on the accuracy of new calculations of parity nonconservation in thallium(M. Kozlov et al.), Phys Rev. A64, 053107 (2001). In our apparatus, a laser beam interacts transversely with a dense, 2-cm-wide thallium beam and reveals roughly tenfold Doppler narrowing of the absorption profile. Having completed a new 0.4% measurement of the Stark shift within the 378 nm 6P_1/2-7S_1/2 E1 transition, we have now begun to study the weak 1283 nm 6P_1/2-6P_3/2 transition in the atomic beam. We seek to determine both Stark shift components, as well as the various components of the Stark-induced amplitude within this mixed M1/E2 transition. Using these existing laser systems, we have also begun a vapor cell spectroscopy study of the 1301 nm 7S_1/2-7P_1/2 E1 transition by means of a two-step excitation from the ground state. To enhance the visibility of these weak absorption signals, we are employing an FM spectroscopy technique. The demodulated laser transmission spectrum provides a low-noise, zero-background signal, and includes replicas of the absorption spectrum separated by the well-known RF sideband frequency, offering built-in frequency scale calibration.

  8. High-Precision Nucleation Rate Measurements for Higher Melting Metals

    NASA Astrophysics Data System (ADS)

    Bokeloh, Joachim; Wilde, Gerhard

    2014-08-01

    Nucleation of a crystal in undercooled melts of higher melting face-centered-cubic-metals has often been studied in the past. However, the data available were not of sufficient accuracy and only covered nucleation rates in too small of a range to allow precise conclusions concerning the nature of the underlying process as well as concerning important parameters such as the solid-liquid interface free energy that can in principle be deducted from such analyses. One way to circumvent ambiguities and analyze nucleation kinetics under well-defined conditions experimentally is given by performing statistically significant numbers of repeated single droplet experiments. Application of proper statistics analyses yields nucleation rates that are independent of a specific nucleation model. The first studies that were conducted in accordance with this approach on pure model materials revealed that the approach is valid. The results are comparable to those obtained by classic nucleation theory applied to experimental data, and it was shown that one might need to rethink the common assumption that heterogeneous nucleation is almost always responsible for solidification initiation. The current results also show that often-used models for the solid-liquid interface free energy might lead to overestimated values.

  9. High Performance and Increased Precision Techniques for Feynman Loop Integrals

    NASA Astrophysics Data System (ADS)

    Kato, K.; de Doncker, E.; Ishikawa, T.; Kapenga, J.; Olagbemi, O.; Yuasa, F.

    2016-10-01

    For the investigation of physics within and beyond the Standard Model, a precise evaluation of higher order corrections in perturbative quantum field theory is required. We have worked on the development of a computational method for Feynman loop integrals with a fully numerical approach. It is based on numerical integration and extrapolation techniques. In this paper, we describe the status and new developments in our techniques for the numerical computation of Feynman loop integrals. Separation of ultra-violet divergences is important for the renormalization procedure. In our analyses, the separation can be done numerically. For 2-loop integrals we have performed the calculations for up to 4-point functions, and for 2-point functions we can handle up to 4- loop integrals. We report the status and accuracy of the computations with detailed numerical comparisons to results in the literature, in order to demonstrate that our method will evolve into an important component of automated systems for the study of higher-order radiative corrections.

  10. High Precision Photometry of Bright Transiting Exoplanet Hosts

    NASA Astrophysics Data System (ADS)

    Wilson, Maurice; Eastman, Jason; Johnson, John A.

    2016-01-01

    Within the past two decades, the successful search for exoplanets and the characterization of their physical properties have shown the immense progress that has been made towards finding planets with characteristics similar to Earth. For most exoplanets with a radius about the size of Earth, evaluating their physical properties, such as the mass, radius and equilibrium temperature, cannot be determined with satisfactory precision. The MINiature Exoplanet Radial Velocity Array (MINERVA) was recently built to obtain spectroscopic and photometric measurements to find, confirm, and characterize Earth-like exoplanets. MINERVA's spectroscopic survey targets the brightest, nearby stars which are well-suited to the array's capabilities, while its primary photometric goal is to search for transits around these bright targets. Typically, it is difficult to find satisfactory comparison stars within a telescope's field of view when the primary target is very bright. This issue is resolved by using one of MINERVA's telescopes to observe the primary bright star while the other telescopes observe a distinct field of view that contains satisfactory bright comparison stars. We describe the code used to identify nearby comparison stars, schedule the four telescopes, produce differential photometry from multiple telescopes, and show the first results from this effort.This work has been funded by the Ronald E. McNair Post-Baccalaureate Achievement Program, the ERAU Honors Program, the ERAU Undergraduate Research Spark Fund, and the Banneker Institute at the Harvard-Smithsonian Center for Astrophysics.

  11. High precision silicon piezo resistive SMART pressure sensor

    NASA Astrophysics Data System (ADS)

    Brown, Rod

    2005-01-01

    Instruments for test and calibration require a pressure sensor that is precise and stable. Market forces also dictate a move away from single measurand test equipment and, certainly in the case of pressure, away from single range equipment. A pressure `module' is required which excels in pressure measurement but is interchangble with sensors for other measurands. A communications interface for such a sensor has been specified. Instrument Digital Output Sensor (IDOS) that permits this interchanagability and allows the sensor to be inside or outside the measuring instrument. This paper covers the design and specification of a silicon diaphragm piezo resistive SMART sensor using this interface. A brief history of instrument sensors will be given to establish the background to this development. Design choices of the silicon doping, bridge energisation method, temperature sensing, signal conversion, data processing, compensation method, communications interface will be discussed. The physical format of the `in-instrument' version will be shown and then extended to the packaging design for the external version. Test results will show the accuracy achieved exceeds the target of 0.01%FS over a range of temperatures.

  12. Design of a high-precision β-telescope

    NASA Astrophysics Data System (ADS)

    Terbeek, R. H.; Behling, S.; Melconian, D.

    2009-10-01

    The question is raised of whether or not parity is maximally violated in the weak interaction, focusing on β decay. Efforts to measure the neutrino asymmetry parameter, Bν, and how it will provide limits on the existence of a new right-handed W boson are described. In this experiment, a magneto-optical trap is used to laser-cool and confine ^37K atoms, which are then polarized using optical pumping techniques. A β-telescope will be used to detect the energy and direction of the e^+s emitted from the decay. This detector will be used in coincidence with a microchannel plate which observes the momentum of the recoiling ^37Ar nucleus. The kinematics of the decay allow us to deduce the neutrino's momentum event-by-event, and so by correlating the neutrino's momentum with the initial nuclear spin, we will be able to make a precision measurement of Bν. The physics of positron detection and constraints on β-telescope design are covered in detail, as well as research into computer simulation methods for the analysis of response functions and the optimization of certain parameters of a β-telescope.

  13. High-speed precision weighing of pharmaceutical capsules

    NASA Astrophysics Data System (ADS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2009-11-01

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements.

  14. High-precision timeline for Earth's most severe extinction.

    PubMed

    Burgess, Seth D; Bowring, Samuel; Shen, Shu-zhong

    2014-03-04

    The end-Permian mass extinction was the most severe loss of marine and terrestrial biota in the last 542 My. Understanding its cause and the controls on extinction/recovery dynamics depends on an accurate and precise age model. U-Pb zircon dates for five volcanic ash beds from the Global Stratotype Section and Point for the Permian-Triassic boundary at Meishan, China, define an age model for the extinction and allow exploration of the links between global environmental perturbation, carbon cycle disruption, mass extinction, and recovery at millennial timescales. The extinction occurred between 251.941 ± 0.037 and 251.880 ± 0.031 Mya, an interval of 60 ± 48 ka. Onset of a major reorganization of the carbon cycle immediately precedes the initiation of extinction and is punctuated by a sharp (3‰), short-lived negative spike in the isotopic composition of carbonate carbon. Carbon cycle volatility persists for ∼500 ka before a return to near preextinction values. Decamillenial to millennial level resolution of the mass extinction and its aftermath will permit a refined evaluation of the relative roles of rate-dependent processes contributing to the extinction, allowing insight into postextinction ecosystem expansion, and establish an accurate time point for evaluating the plausibility of trigger and kill mechanisms.

  15. Application of GPS in a high precision engineering survey network

    SciTech Connect

    Ruland, R.; Leick, A.

    1985-04-01

    A GPS satellite survey was carried out with the Macrometer to support construction at the Stanford Linear Accelerator Center (SLAC). The network consists of 16 stations of which 9 stations were part of the Macrometer network. The horizontal and vertical accuracy of the GPS survey is estimated to be 1 to 2 mm and 2 to 3 mm respectively. The horizontal accuracy of the terrestrial survey, consisting of angles and distances, equals that of the GPS survey only in the ''loop'' portion of the network. All stations are part of a precise level network. The ellipsoidal heights obtained from the GPS survey and the orthometric heights of the level network are used to compute geoid undulations. A geoid profile along the linac was computed by the National Geodetic Survey in 1963. This profile agreed with the observed geoid within the standard deviation of the GPS survey. Angles and distances were adjusted together (TERRA), and all terrestrial observations were combined with the GPS vector observations in a combination adjustment (COMB). A comparison of COMB and TERRA revealed systematic errors in the terrestrial solution. A scale factor of 1.5 ppM +- .8 ppM was estimated. This value is of the same magnitude as the over-all horizontal accuracy of both networks. 10 refs., 3 figs., 5 tabs.

  16. Near-anode focusing phenomenon caused by the high anolyte concentration in the electrokinetic remediation of chromium(VI)-contaminated soil.

    PubMed

    Li, Dong; Xiong, Zhen; Nie, Yang; Niu, Yuan-Yuan; Wang, Li; Liu, Yuan-Yuan

    2012-08-30

    The effects of the concentration and the low pH value of anolyte on the electrokinetic remediation (EKR) of chromium-contaminated soil were investigated using chromium-spiked kaolin-gypsum soil. Results of visual observation and X-ray fluorescence analysis show that high anolyte concentrations could cause an ion-induced potential gradient well trapping effect on the soil near the anode, and consequently cause a focusing phenomenon (FP) without chemical precipitation. This FP significantly prolonged the remediation duration and reduced chromium removal. The low pH value of soil aggravated the FP, resulting in a quasi-dead zone near the anode caused by the reduction in soil resistance, rather than the adsorption of chromium (VI) ions. The high anolyte concentration also resulted in high energy consumption. The FP and low pH value collectively decreased the energy efficiency by more than 96%. This kind of FP can be predicted via the online monitoring of the potential gradient profiles of the soil between the electrodes in the EKR.

  17. New linear piezomotors for high-force precise positioning applications

    NASA Astrophysics Data System (ADS)

    Le Letty, Ronan; Claeyssen, Frank; Barillot, Francois; Six, Marc F.; Bouchilloux, Philippe

    1998-07-01

    Piezomotors are an increasingly competitive alternative to electromagnetic stepper motors, especially in applications where large bandwidths and/or precise positioning control are desired. Piezomotors use a combination of electromechanical and frictional forces and, compared to conventional electromagnetic motors, have the advantages that no power supply is required to maintain the motor in position and no lubrication is necessary in the device. The operating principle of these motors relies on the use of an ultrasonic vibration, which is created via the piezoelectric effect (at resonance in most cases), in order to generate vibration forces at the `stator/rotor' contact interface. A mechanical preload is also applied at this contact interface and is responsible for the motor's holding force at rest. To meet the specifications of an aerospace application, we developed a new design of Linear PiezoMotors (LPMs). The first prototype we built shows very promising results, and makes the LPM a serious candidate to replace conventional stepper motors. The LPM features the following characteristics: a standing force of 100 N, a blocked force of 37 N, a maximum actuation speed of 23 mm/s, a maximum run of 10 mm, a mass of 500 g, an electrical power of 2.2 W, and a position accuracy superior to 1 micrometers . To our knowledge, the driving force delivered by the LPM has never before been achieved in resonant devices. This paper describes the physical operating principles of the LPM, as well as the modeling tools and experimental techniques we used for its development. Several implementation schemes are also presented and show the wide range of possible applications offered by the linear piezomotor.

  18. High-precision structure fabrication based on an etching resistance layer

    NASA Astrophysics Data System (ADS)

    Zhang, Man; Deng, Qiling; Shi, Lifang; Cao, Axiu; Pang, Hui; Liu, Xin; Wang, Jiazhou; Hu, Song

    2016-10-01

    The high-precision fabrication of micro-/nano-structure is a challenge. In this paper, we proposed a new fabrication method of high-precision structure based on an etching resistance layer. The high-precision features were fabricated by photolithography technique, followed by the etching process to transfer the features to the substrate. During this process, the etching uniformity and error lead to the feature distortion. We introduced an etching resistance layer between feature layer and substrate. The etching process will stop when arriving at the resistance layer. Due to the high precision of the plating film, the high-precision structure depth was achieved. In our experiment, we introduced aluminum trioxide as the etching resistance layer. The structures with low depth error of less than 5% were fabricated.

  19. Application of high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for determination of chromium compounds in the air at the workplace.

    PubMed

    Stanislawska, Magdalena; Janasik, Beata; Wasowicz, Wojciech

    2013-12-15

    The toxicity and bioavailability of chromium species are highly dependable on the form or species, therefore determination of total chromium is insufficient for a complete toxicological evaluation and risk assessment. An analytical method for determination of soluble and insoluble Cr (III) and Cr (VI) compounds in welding fume at workplace air has been developed. The total chromium (Cr) was determined by using quadruple inductively coupled plasma mass spectrometry (ICP-MS) equipped with a dynamic reaction cell (DRC(®)). Soluble trivalent and hexavalent chromium compounds were determined by high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). A high-speed, reversed-phase CR C8 column (PerkinElmer, Inc., Shelton, CT, USA) was used for the speciation of soluble Cr (III) and soluble Cr (VI). The separation was accomplished by interaction of the chromium species with the different components of the mobile phase. Cr (III) formed a complex with EDTA, i.e. retained on the column, while Cr (VI) existed in the solutions as dichromate. Alkaline extraction (2% KOH and 3% Na2CO3) and anion exchange column (PRP-X100, PEEK, Hamilton) were used for the separation of the total Cr (VI). The results of the determination of Cr (VI) were confirmed by the analysis of the certified reference material BCR CRM 545 (Cr (VI) in welding dust). The results obtained for the certified material (40.2±0.6 g kg(-1)) and the values recorded in the examined samples (40.7±0.6 g kg(-1)) were highly consistent. This analytical method was applied for the determination of chromium in the samples in the workplace air collected onto glass (Whatman, Ø 37 mm) and membrane filters (Sartorius, 0.8 μm, Ø 37 mm). High performance liquid chromatography with inductively coupled plasma mass spectrometry is a remarkably powerful and versatile technique for determination of chromium species in welding fume at workplace air. Crown Copyright © 2013 Published by

  20. Design and development of a high-precision, high-payload telescope dual-drive system

    NASA Astrophysics Data System (ADS)

    Worthington, Michael S.; Beets, Timothy A.; Beno, Joseph H.; Mock, Jason R.; Murphy, Brian T.; South, Brian J.; Good, John M.

    2010-07-01

    A high precision, dual drive system has been designed and developed for the Wide Field Upgrade to the Hobby-Eberly Telescope* at McDonald Observatory in support of the Hobby-Eberly Telescope Dark Energy Experiment‡. Analysis, design and controls details will be of interest to designers of large scale, high precision robotic motion devices. The drive system positions the 19,000 kg star tracker to a precision of less than 5 microns along its 4-meter travel. While positioning requirements remain essentially equal to the existing HET, tracker mass increases by a factor greater than 5. The 10.5-meter long tracker is driven at each end by planetary roller screws, each having two distinct drive sources dictated by the desired operation: one slowly rotates the screw when tracking celestial objects and the second rotates the nut for rapid displacements. Key results of the roller screw rotordynamics analysis are presented. A description of the complex bearing arrangement providing required degrees of freedom as well as the impact of a detailed Failure Modes and Effects Analysis addressing necessary safety systems is also presented. Finite element analysis results demonstrate how mechanical springs increase the telescope's natural frequency response by 22 percent. The critical analysis and resulting design is provided.

  1. A novel power source for high-precision, highly efficient micro w-EDM

    NASA Astrophysics Data System (ADS)

    Chen, Shun-Tong; Chen, Chi-Hung

    2015-07-01

    The study presents the development of a novel power source for high-precision, highly efficient machining of micropart microstructures using micro wire electrical discharge machining (w-EDM). A novel power source based on a pluri resistance-capacitance (pRC) circuit that can generate a high-frequency, high-peak current with a short pulse train is proposed and designed to enhance the performance of micro w-EDM processes. Switching between transistors is precisely controlled in the designed power source to create a high-frequency short-pulse train current. Various microslot cutting tests in both aluminum and copper alloys are conducted. Experimental results demonstrate that the pRC power source creates instant spark erosion resulting in markedly less material for removal, diminishing discharge crater size, and consequently an improved surface finish. A new evaluation approach for spark erosion ability (SEA) to assess the merits of micro EDM power sources is also proposed. In addition to increasing the speed of micro w-EDM by increasing wire feed rates by 1.6 times the original feed rate, the power source is more appropriate for machining micropart microstructures since there is less thermal breaking. Satisfactory cutting of an elaborate miniature hook-shaped structure and a high-aspect ratio microstructure with a squared-pillar array also reveal that the developed pRC power source is effective, and should be very useful in the manufacture of intricate microparts.

  2. HYDRA: High Speed Simulation Architecture for Precision Spacecraft Formation Flying

    NASA Technical Reports Server (NTRS)

    Martin, Bryan J.; Sohl, Garett A.

    2003-01-01

    This viewgraph presentation describes HYDRA, which is architecture to facilitate high-fidelity and real-time simulation of formation flying missions. The contents include: 1) Motivation; 2) Objective; 3) HYDRA-Description and Overview; 4) HYDRA-Hierarchy; 5) Communication in HYDRA; 6) Simulation Specific Concerns in HYDRA; 7) Example application (Formation Acquisition); and 8) Sample Problem Results.

  3. Pointing Control System for a High Precision Flight Telescope

    SciTech Connect

    BENTLEY,ANTHONY E.; WILCOXEN,JEFFREY LEE

    2000-12-01

    A pointing control system is developed and tested for a flying gimbaled telescope. The two-axis pointing system is capable of sub-microradian pointing stability and high accuracy in the presence of large host vehicle jitter. The telescope also has high agility--it is capable of a 50-degree retarget (in both axes simultaneously) in less than 2 seconds. To achieve the design specifications, high-accuracy, high-resolution, two-speed resolvers were used, resulting in gimbal-angle measurements stable to 1.5 microradians. In addition, on-axis inertial angle displacement sensors were mounted on the telescope to provide host-vehicle jitter cancellation. The inertial angle sensors are accurate to about 100 nanoradians, but do not measure low frequency displacements below 2 Hz. The gimbal command signal includes host-vehicle attitude information, which is band-limited. This provides jitter data below 20 Hz, but includes a variable latency between 15 and 25 milliseconds. One of the most challenging aspects of this design was to combine the inertial-angle-sensor data with the less perfect information in the command signal to achieve maximum jitter reduction. The optimum blending of these two signals, along with the feedback compensation were designed using Quantitative Feedback Theory.

  4. High-Precision Registration of Point Clouds Based on Sphere Feature Constraints.

    PubMed

    Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter

    2016-12-30

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method.

  5. High-Precision Registration of Point Clouds Based on Sphere Feature Constraints

    PubMed Central

    Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter

    2016-01-01

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method. PMID:28042846

  6. Coating-free mirrors for high precision interferometric experiments

    SciTech Connect

    Gossler, Stefan; Cumpston, Jeff; McKenzie, Kirk; Mow-Lowry, Conor M.; Gray, Malcolm B.; McClelland, David E.

    2007-11-15

    Thermal noise in mirror optical coatings may not only limit the sensitivity of future gravitational-wave detectors in their most sensitive frequency band but is also a major impediment for experiments that aim to reach the standard quantum limit or cool mechanical systems to their quantum ground state. We present the design and experimental characterization of a highly reflecting mirror without any optical coating. This coating-free mirror is based on total internal reflection and Brewster-angle coupling. In order to characterize its performance, the coating-free mirror was incorporated into a triangular ring cavity together with a high quality conventional mirror. The finesse of this cavity was measured using an amplitude transfer function to be about F{approx_equal}4000. This finesse corresponds to a reflectivity of the coating-free mirror of about R{approx_equal}99.89%. In addition, the dependence of the reflectivity on rotation was mapped out.

  7. High speed precision motion strategies for lightweight structures

    NASA Technical Reports Server (NTRS)

    Book, Wayne J.

    1987-01-01

    Work during the recording period proceeded along the lines of the proposal, i.e., three aspects of high speed motion planning and control of flexible structures were explored: fine motion control, gross motion planning and control, and automation using light weight arms. In addition, modeling the large manipulator arm to be used in experiments and theory has lead to some contributions in that area. These aspects are reported below. Conference, workshop and journal submissions, and presentations related to this work were seven in number, and are listed. Copies of written papers and abstracts are included.

  8. Spectral band passes for a high precision satellite sounder

    NASA Technical Reports Server (NTRS)

    Kaplan, L. D.; Chahine, M. T.; Susskind, J.; Searl, J. E.

    1977-01-01

    Atmospheric temperature soundings with significantly improved vertical resolution can be obtained from carefully chosen narrow band-pass measurements in the 4.3-micron band of CO2 by taking advantage of the variation of the absorption coefficients, and thereby the weighting functions, with pressure and temperature. A set of channels has been found in the 4.2-micron region that is capable of yielding about 2-km vertical resolution in the troposphere. The concept of a complete system is presented for obtaining high resolution retrievals of temperature and water vapor distribution, as well as surface and cloud top temperatures, even in the presence of broken clouds.

  9. Combination spindle-drive system for high precision machining

    DOEpatents

    Gerth, Howard L.

    1977-07-26

    A combination spindle-drive is provided for fabrication of optical quality surface finishes. Both the spindle-and-drive utilize the spindle bearings for support, thereby removing the conventional drive-means bearings as a source of vibration. An airbearing spindle is modified to carry at the drive end a highly conductive cup-shaped rotor which is aligned with a stationary stator to produce torque in the cup-shaped rotor through the reaction of eddy currents induced in the rotor. This arrangement eliminates magnetic attraction forces and all force is in the form of torque on the cup-shaped rotor.

  10. Decentralized high precision telemetry and telecommand system for sounding rockets

    NASA Astrophysics Data System (ADS)

    Heyer, Heinz-Volker; Schmitt, Günter; Pfeuffer, Horst; Voss, Bernhard

    2005-08-01

    TEXUS and MAXUS payloads are currently providing 12 bit analog channel accuracy for their data acquisition chains with different signal conditioning elements such as temperature measurement, strain gauge, pressure measurement channels, and general purpose amplifiers. Transient recording functions are rather seldom as all data is directly transmitted via PCM to the ground station. However, the user requirements are steadily increasing in terms of accuracy, data security, and high data throughput rate with an ever increasing number of telemetry channels. The newly developed Kayser-Threde telemetry and telecommand system CTS 3000 (Compact Telemetry System) fulfils these requirements by providing up to 16 bit accuracy for its analog channels with a sampling rate up to 2 kHz (at this accuracy), on-board transient memory to protect against data loss and provides an integrated telecommand decoder at the same time, reducing the necessary amount of equipment used for instrumentation. The equipment further reduces the necessary effort for refurbishment because of its internal self calibration over the full environment temperature range. On top of its IRIG PCM interface the system is equipped with a USB bus, a well-known and commonly used PC standard high performance interface. This interface is used for configuration, testing, and monitoring of the CTS 3000 providing a simple and easy to use user environment for the new equipment. The paper will introduce the new equipment and will show the application in the TEXUS/MAXUS project.

  11. High precision moving magnet chopper for variable operation conditions

    NASA Technical Reports Server (NTRS)

    Aicher, Winfried; Schmid, Manfred

    1994-01-01

    In the context of an ESTEC technology contract, a Chopping Mechanism was developed and built with the Far Infrared and Submillimeter Telescope (FIRST) astronomy mission as a reference. The task of the mechanism is to tilt the subreflector of the telescope with an assumed mass of 2.5 kg about one chopping axis at nominal frequencies of up to 5 Hz and chopping angles of up to +/- 11.25 mrad with high efficiency (minimum time for position change). The chopping axis is required to run through the subreflector vertex. After performing a concept trade-off also considering the low operational temperatures in the 130 K range, a design using moving magnet actuators was found to be the favorite one. In addition, a bearing concept using flexible pivots was chosen to meet the high chopping accuracy required. With this approach, a very reliable design could be realized, since the actuators work without any mechanical contact between its moving and fixed parts, and the only bearings used are two flexible pivots supporting the subreflector mounting interface. The mechanism was completely built in titanium in a lightweight and stiff design. The moving magnet actuators were designed to meet the stringent requirements for minimum risetime (time necessary to move from one angular position to a new one) in the 20 msec range. The angular position and the corresponding chopping frequency as well can be arbitrarily selected by the user.

  12. Unraveling high precision stereocontrol in a triple cascade organocatalytic reaction.

    PubMed

    Shinisha, C B; Sunoj, Raghavan B

    2008-11-07

    The mechanism and stereoselectivity in an organocatalyzed triple cascade reaction between an aldehyde, electron deficient olefin and an alpha,beta-unsaturated aldehyde are investigated for the first time using density functional theory. The factors responsible for high levels of observed stereoselectivity (Enders et al., Nature, 2006, 441, 861) towards the generation of cyclohexene carbaldehyde with four contiguous stereocentres are unravelled. The triple cascade reaction, comprising a Michael, Michael and aldol sequence as the key elementary reactions, is studied by identifying the corresponding transition states for the stereoselective C-C bond-formation. In the first Michael addition step between the enamine (derived from the chiral catalyst and propanal) and nitrostyrene, energetically the most preferred mode of addition is found to be between the si-face of (E)-anti-enamine on the si-face of nitrostyrene. The addition of the si-face of the nitroalkane anion on the re-face of the iminium ion (formed between the enal and the catalyst) is the lowest energy pathway for the second Michael addition step. The high level of asymmetric induction is rationalized with the help of relative activation barriers associated with the competitive diastereomeric pathways. Interesting weak interactions, along with the steric effects offered by the bulky alpha-substituent on the pyrrolidine ring, are identified as critical to the stereoselectivity in this triple cascade reaction. The predicted stereoselectivities using computed energetics are found to be in perfect harmony with the experimental stereoselectivities.

  13. High integrity GPS/INS filter for precise relative navigation

    NASA Astrophysics Data System (ADS)

    Abdel-Hafez, Mamoun F.

    A GPS/INS filter design for absolute and relative state estimation is discussed. The GPS code and Doppler measurements are used for absolute state estimation while the GPS carrier phase and Doppler measurements are used for relative state estimation. Real-time results obtained from a Hardware-in-the-Loop Simulation and actual F-18 flight tests are presented. To ensure accurate state estimation, the observability of the GPS/INS system is analyzed analytically when the system is at rest and during maneuvers. The system observability enhancement during two different maneuvers is discussed. Simulation results illustrating the observability of the system during the different stages of the GPS/INS system operation are also presented. To allow successful use of the high-accuracy carrier phase measurements, two methods for resolving GPS integer ambiguity are introduced. The first combines an efficient method for obtaining the admissible integer ambiguity hypotheses within a probabilistic volume with an integer hypothesis testing method to reduce the convergence time with high probability to the GPS carrier phase integers. The second GPS integer ambiguity resolution method is based on a log-formulation of the Multiple Hypothesis Wald Sequential Probability Test (MHWSPT). The computational time requirement of the latter method is shown to be smaller than the former method. Real-time results are presented to show the performance of the two methods introduced.

  14. Synthesis and Magnetism of High Curie Temperature Prussian Blue Analogue Molecular Nanomagnet-Chromium Cyanide Molecule Nanowire Arrays

    NASA Astrophysics Data System (ADS)

    Zhou, Pingheng; Xue, Desheng; Yao, Jinli

    2009-03-01

    The goal to synthesize molecular nanomagnets that exhibit spontaneous magnetic ordering close to room temperature might enable one to apply them in the fields of magnetic memory devices and microelectronics. Chromium cyanide molecule nanowire arrays with diameters of about 50 nm and lengths up to 4μm have been synthesized by an electrodepositing technology based on anodizing anodic aluminum oxide films. Characterization measurements show that the oxidation state of the chromium ions in the chromium cyanide nanowires can be expressed as Cr^3+--CN--Cr^3+. Magnetic properties measurements indicate that the Curie temperature of chromium cyanide nanowire is 200 K, which is closer room temperature compared with current molecular nanomagnet systems.

  15. High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus

    NASA Astrophysics Data System (ADS)

    Fasanella, G.

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillation lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3%/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  16. High-precision metrology of highly charged ions via relativistic resonance fluorescence.

    PubMed

    Postavaru, O; Harman, Z; Keitel, C H

    2011-01-21

    Resonance fluorescence of laser-driven highly charged ions is investigated with regard to precisely measuring atomic properties. For this purpose an ab initio approach based on the Dirac equation is employed that allows for studying relativistic ions. These systems provide a sensitive means to test correlated relativistic dynamics, quantum electrodynamic phenomena and nuclear effects by applying x-ray lasers. We show how the narrowing of sidebands in the x-ray fluorescence spectrum by interference due to an additional optical driving can be exploited to determine atomic dipole or multipole moments to unprecedented accuracy.

  17. High precision, medium flux rate CZT spectroscopy for coherent scatter imaging

    NASA Astrophysics Data System (ADS)

    Greenberg, Joel A.; Hassan, Mehadi; Brady, David J.; Iniewski, Kris

    2016-05-01

    CZT detectors are primary candidates for many next-generation X-ray imaging systems. These detectors are typically operated in either a high precision, low flux spectroscopy mode or a low precision, high flux photon counting mode. We demonstrate a new detector configuration that enables operation in a high precision, medium flux spectroscopy mode, which opens the potential for a variety of new applications in medical imaging, non-destructive testing and baggage scanning. In particular, we describe the requirements of a coded aperture coherent scattering X-ray system that can perform fast imaging with accurate material discrimination.

  18. Stellar Astrophysics Using Ultra-High Precision CCD Time Series Photometry

    NASA Astrophysics Data System (ADS)

    Howell, S.; Everett, M.; Huber, M.; Ciardi, D.; van Belle, G.

    2001-05-01

    Using time-series CCD photometry and a wide-field imager, we have extended the techniques of differential photometry to provide robust photometric precisions for each star over the entire field of view. Reaching photometric precisions of 2 milli-magnitudes, we produced high cadence light curves for over 12,000 stars at mid- and high galactic latitude. The fraction of stars seen to be variable is higher than the canonical wisdom, being 10-14 will present the details of our techniques, sample light curves, methods to access the data, and a summary of astrophysical uses of such high precision data.

  19. High Precision Assembly of Thin Mirror X-ray Telescopes

    NASA Astrophysics Data System (ADS)

    Schattenburg, Mark

    Lightweight high resolution x-ray telescope optics are one of the key technologies under development for next-generation x-ray telescopes. The ultimate goal of this effort is to realize optics with spatial resolution rivaling Chandra (<1 arc-sec) but with collecting areas that are larger by orders of magnitude. In the USA several institutions, including GSFC, MSFC, Harvard-SAO, MIT and Northwest University are working on a variety of approaches to this problem. An excellent example is the NuSTAR x-ray telescope, which teamed Cal Tech, GSFC, Columbia University and LLNL to produce a superb set of hard x-ray optics. The telescope was composed of thousands of 0.2 mm-thick glass mirrors which were epoxied into place around a spindle structure. While very light weight, this process resulted in ~1 arc min resolution. We want to achieve ~100 times better with similar mass. A group at NASA GSFC has recently demonstrated an alternative thin-glass assembly procedure that has achieved ~7 arc sec resolution with x-ray tests. Further progress towards 1 arc-sec will require mirrors with improved figure, lower stress coatings, improved alignment, better metrology, and low stress bonding. Many of the difficulties with current mirror assembly practice stem from the use of epoxy as a bonding agent. Epoxy has many disadvantages, including high shrinkage, large CTE and creep, resin aging effects, water absorption, outgassing, low tensile strength, exothermicity, and requiring large amounts of time and/or heat to cure. These effects can cause errors that become â€oefrozen in― to the bond with no possibility of correction. We propose to investigate replacing epoxy with low temperature, low shrinkage solder alloys. We use these solders in conjunction with high power, millisec-long pulses from a fiber IR laser to deliver controlled amounts of heat into the bond area. We have demonstrated that laser pulses can be used to actuate carefully designed bonds by permanently compressing

  20. Calibration, registration, and synchronization for high precision augmented reality haptics.

    PubMed

    Harders, Matthias; Bianchi, Gérald; Knoerlein, Benjamin; Székely, Gábor

    2009-01-01

    In our current research we examine the application of visuo-haptic augmented reality setups in medical training. To this end, highly accurate calibration, system stability, and low latency are indispensable prerequisites. These are necessary to maintain user immersion and avoid breaks in presence which potentially diminish the training outcome. In this paper we describe the developed calibration methods for visuo-haptic integration, the hybrid tracking technique for stable alignment of the augmentation, and the distributed framework ensuring low latency and component synchronization. Finally, we outline an early prototype system based on the multimodal augmented reality framework. The latter allows colocated visuo-haptic interaction with real and virtual scene components in a simplified open surgery setting.

  1. High Precision SC Cavity Diagnostics with HOM Measurements

    SciTech Connect

    Frisch, Josef; Hendrickson, Linda; McCormick, Douglas; May, Justin; Molloy, Stephen; Ross, Marc; /SLAC

    2006-08-18

    Experiments at the FLASH linac at DESY have demonstrated that the Higher Order Modes induced in Superconducting Cavities can be used to provide a variety of beam and cavity diagnostics. The centers of the cavities can be determined from the beam orbit which produces minimum power in the dipole HOM modes. The phase and amplitude of the dipole modes can be used as a high resolution beam position monitor, and the phase of the monopole modes to measure the beam phase relative to the accelerator RF. Beam orbit feedback which minimizes the dipole HOM power in a set of structures has been demonstrated. For most SC accelerators, the existing HOM couplers provide the necessary signals, and the down mix and digitizing electronics are straightforward, similar to those for a conventional BPM.

  2. Derivative properties from high-precision equations of state.

    PubMed

    Haghbakhsh, Reza; Konttorp, Morten; Raeissi, Sona; Peters, Cor J; O'Connell, John P

    2014-12-11

    In this study, the behavior of derivative properties estimated by equations of state, including isochoric heat capacity, isobaric heat capacity, speed of sound, and the Joule-Thomson coefficient for pure compounds and a mixture, has been investigated. The Schmidt-Wagner and Jacobsen-Stewart equations of state were used for predictions of derivative properties of 10 different pure compounds from various nonpolar hydrocarbons, nonpolar cyclic hydrocarbons, polar compounds, and refrigerants. The estimations were compared to experimental data. To evaluate the behavior of mixtures, the extended corresponding states principle (ECS) was studied. Analytical relationships were derived for isochoric heat capacity, isobaric heat capacity, the Joule-Thomson coefficient, and the speed of sound. The ECS calculations were compared to the reference surface data of methane + ethane. The ECS principle was found to generate data of high quality.

  3. Development of Large Current High Precision Pulse Power Supply

    NASA Astrophysics Data System (ADS)

    Takayanagi, Tomohiro; Koseki, Shoichiro; Kubo, Hiroshi; Katoh, Shuji; Ogawa, Shinichi

    JAEA and KEK are jointly constructing a high intensity proton accelerator project J-PARC. Its main accelerator is 3GeV synchrotron. Its injection bump magnets, especially horizontal paint bump magnets, are excited by large pulse currents. Their rated currents are over 10kA and pulse widths are about 1ms. Tracking errors are required to be less than 1%. Multiple connected two-quadrant IGBT choppers are adopted for their power supplies. Their output currents are controlled by feedback control with minor loop voltage control (m-AVR). When output current of a chopper intermits at small current, its output voltage rises up and current control becomes difficult. In this paper response of m-AVR and output voltage characteristics at current intermittent region are studied and an improved control scheme is proposed. The performance is confirmed by a test.

  4. Precision high energy liner implosion experiments PHELIX [1

    SciTech Connect

    Reass, William A; Baca, David M; Griego, Jeffrey R; Reinovsky, Robert E; Rousculp, Christopher L; Turchi, Peter J

    2009-01-01

    This paper describes the hardware design of a small megajoule sized transformer coupled pulse power system utilized to drive hydrodynamic liner experiments with a nominal current capability of 10 megAmperes. The resulting liner velocities and characteristics provide properties of physics interest. The capacitor banks utilize the ''Atlas'' plastic cased 60 kV, 60 kJ capacitors [2] and railgaps [3]. The air insulated marx'S are configured to dive a multi-filar toroidal transformer. The 4:1 multi-filar toroidal transformer is mechanically part of a circular disc line and this feature results in an attractive inductance budget. Because of the compact size, re-usable transformer, and resulting low maintenance cost, shot rates can be high compared to other ''large'' machines or explosively driven hydrodynamic methods. The PHELIX modeling, construction status, and test results will also be provided.

  5. A high precision calorimeter for the SOX experiment

    NASA Astrophysics Data System (ADS)

    Papp, L.; Agostini, M.; Altenmüller, K.; Appel, S.; Caminata, A.; Cereseto, R.; Di Noto, L.; Farinon, S.; Musenich, R.; Neumair, B.; Oberauer, L.; Pallavicini, M.; Schönert, S.; Testera, G.; Zavatarelli, S.

    2016-07-01

    The SOX (Short distance neutrino Oscillations with BoreXino) experiment is being built to discover or reject eV-scale sterile neutrinos by observing short baseline oscillations of active-to-sterile neutrinos [1]. For this purpose, a 100 kCi 144Ce-144Pr antineutrino generator (CeSOX) will be placed under the BOREXINO detector at the Laboratori Nazionali del Gran Sasso. Thanks to its large size and very low background, BOREXINO is an ideal detector to discover or reject eV-scale sterile neutrinos. To reach the maximal sensitivity, we aim at determining the neutrino flux emitted by the antineutrino generator with a < 1 % accuracy. With this goal, TU München and INFN Genova are developing a vacuum calorimeter, which is designed to measure the source-generated heat with high accuracy.

  6. High precision pointing with a multiline spectrometer at the VTT

    NASA Astrophysics Data System (ADS)

    Staiger, J.

    2012-12-01

    We are investigating the pointing quality of the VTT, Tenerife under the aspect of suitability for long-term heliosesimological observations. Tests have shown that thermal and mechanical loads within the telescope may create spurious image drifts with shift rates of up to 5 arcsec per hour. During daylong recordings this will reduce significantly the effective size of the field-of-view and may infer artificial lateral movements into the data. The underlying problem that not all image position offsets developing during a measurement may be compensated for is common to most high-resolution solar telescopes independently of the type of pointing system used. We are developing new approaches to address this problem which are to be tested in the near future at the VTT. The simulations established so far show that the problem may be reduced by more than 90 %.

  7. Creating high-stability high-precision bipolar trim power supply

    SciTech Connect

    Chen, Zhe; Merz, William A.

    2012-07-01

    Thomas Jefferson National Accelerator Facility (TJNAF) is founded by the US Department of Energy (DOE) office of science for the technology advancement and physics research in electron beam accelerator. This facility has the state of the art technology to carry out world-class cutting-edge experiments for the nucleus composition and atomic characteristics identification and exploration for the nature of the matter in the universe. A continuous wave electron beam is featured for such experiments, thus precise and stable trim power supply is required to meet such purpose. This paper demonstrates the challenges and solutions to design, assemble, fabrication and test such high-precision high-stability power supplies. This paper presents the novel design and first article test of the ±20A ±75V bipolar, 100ppm stability level current-regulated high-power trim power supplies for the beam manipulation. This special design can provide valuable documentation and reference values for future designs and special applications in particle accelerator power supply creation.

  8. High Precision Ti stable Isotope Measurement of Terrestrial Rocks

    NASA Astrophysics Data System (ADS)

    Millet, M. A.; Dauphas, N.; Williams, H. M.; Burton, K. W.; Nowell, G. M.

    2014-12-01

    Advances in multi-collection plasma source mass spectrometry have allowed the determination of stable isotope composition of transition metals to address questions relevant to both high and low temperature geochemistry. However, titanium has received only very limited attention. Here we present a new technique allowing the determination of the stable isotope composition of titanium in geological samples (d49Ti or deviation of the 49Ti/47Ti ratio from the OL-Ti in-house standard of reference) using double-spike methodology and high-resolution MC-ICP-MS. We have carried out a range analytical tests for a wide spectrum of samples matrices to demonstrate a external reproducibility of ±0.02‰ on the d49Ti while using as little as 150ng of natural Ti for a single analysis. We have analysed a comprehensive selection of mantle-derived samples covering a range of geodynamic contexts (MORB, IAB, OIB, adakites, eclogites, serpentines) and geographical distribution (MORB: Mid-Atlantic Ridge, Southwest Indian Ridge and Eastern Pacific Ridge; IAB: New Britain reference suite and Marianas Arc). The samples show a very limited range from -0.06‰ to +0.04‰ with a main mode at +0.004‰ relative to the OL-Ti standard. Average values for MORB, IAB and eclogites are similar within uncertainty and thus argue for limited mobility of Ti during subduction zone processes and homogeneity of the Ti stable isotope composition of the upper mantle. However, preliminary data for more evolved igneous rocks suggest that they display heavier Ti stable isotope compositions, which may reflect the removal of isotopically light Ti as a function of Fe-Ti oxide crystallisation. This is in good agreement with Ti being present in 5-fold and 6-fold coordination in basaltic melts and preferential uptake of 6-folded Ti by Ti-bearing oxides [1]. This dataset will be complemented by analysis of abyssal peridotites to confirm the homogeneity of the mantle as well as data for a range of ferromanganese crusts

  9. New alloys to conserve critical elements. [replacing chromium in steels

    NASA Technical Reports Server (NTRS)

    Stephens, J. R.

    1978-01-01

    Previous studies and surveys on availability of domestic reserves have shown that chromium is a most critical element within the U.S. metal industry. More precisely, the bulk of chromium is consumed in the production of stainless steels, specifically Type 304 stainless steel (304SS) which contains 18% Cr. The present paper deals with means of reducing chromium in commercial stainless steels by substituting more abundant or less expensive elements with the intent of maintaining the properties of 304SS. The discussion focuses on some of the oxidation and corrosion properties of new substitute stainless steels with only 12% Cr, which represents a potential saving of 33% of the chromium consumed in the production of 304SS. The alloying elements substituted for Cr in 304SS are selected according to their potential for protective oxide formation during high-temperature oxidation; these are Al, Si, Ti, Y, and misch metal which is 99.7% rare-earth metals containing 50 to 55% cerium. Other alloying elements to impart corrosion resistance are Mn, Mo, and V.

  10. New alloys to conserve critical elements. [replacing chromium in steels

    NASA Technical Reports Server (NTRS)

    Stephens, J. R.

    1978-01-01

    Previous studies and surveys on availability of domestic reserves have shown that chromium is a most critical element within the U.S. metal industry. More precisely, the bulk of chromium is consumed in the production of stainless steels, specifically Type 304 stainless steel (304SS) which contains 18% Cr. The present paper deals with means of reducing chromium in commercial stainless steels by substituting more abundant or less expensive elements with the intent of maintaining the properties of 304SS. The discussion focuses on some of the oxidation and corrosion properties of new substitute stainless steels with only 12% Cr, which represents a potential saving of 33% of the chromium consumed in the production of 304SS. The alloying elements substituted for Cr in 304SS are selected according to their potential for protective oxide formation during high-temperature oxidation; these are Al, Si, Ti, Y, and misch metal which is 99.7% rare-earth metals containing 50 to 55% cerium. Other alloying elements to impart corrosion resistance are Mn, Mo, and V.

  11. Chromium in rivers impacted by tannery wastes determined by high performance liquid chromatography - inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pereira de Abreu, M.-H.; Vignati, D.; Dominik, J.

    2003-05-01

    The total chromium concentrations by ICP-MS and HPLC-ICP-MS and the redox chromium species have been determined in rivers impacted by untreated wastes from tanneries at Fès (Morocco). The results obtained by two ICP-MS analysis methods showed significantly different chromium values at m/z 53. The higher values obtained with external calibration, can be attributed to matrix effects, especially ^{37}Cl ^{16}O at m/z 53. This is confirmed on the chromatograms by the presence of a peak at 100s with the anomalous ^{52}Cr/^{53}Cr isotopic ratio. The hexavalent chromium was not detected. Two trivalent chromium monomer species, Cr(OH)(H2O)5^{2+} and Cr(H2O)6^{3+}, were present in low concentrations. We suppose that the major part of chromium occurred as Cr(III) polymeric species which were not retained on the column. These Cr(III) forms are usually complexed with Cl^- or/and SO4^{2-}, used as tanning agents.

  12. High Resolution Airborne Digital Imagery for Precision Agriculture

    NASA Technical Reports Server (NTRS)

    Herwitz, Stanley R.

    1998-01-01

    The Environmental Research Aircraft and Sensor Technology (ERAST) program is a NASA initiative that seeks to demonstrate the application of cost-effective aircraft and sensor technology to private commercial ventures. In 1997-98, a series of flight-demonstrations and image acquisition efforts were conducted over the Hawaiian Islands using a remotely-piloted solar- powered platform (Pathfinder) and a fixed-wing piloted aircraft (Navajo) equipped with a Kodak DCS450 CIR (color infrared) digital camera. As an ERAST Science Team Member, I defined a set of flight lines over the largest coffee plantation in Hawaii: the Kauai Coffee Company's 4,000 acre Koloa Estate. Past studies have demonstrated the applications of airborne digital imaging to agricultural management. Few studies have examined the usefulness of high resolution airborne multispectral imagery with 10 cm pixel sizes. The Kodak digital camera integrated with ERAST's Airborne Real Time Imaging System (ARTIS) which generated multiband CCD images consisting of 6 x 106 pixel elements. At the designated flight altitude of 1,000 feet over the coffee plantation, pixel size was 10 cm. The study involved the analysis of imagery acquired on 5 March 1998 for the detection of anomalous reflectance values and for the definition of spectral signatures as indicators of tree vigor and treatment effectiveness (e.g., drip irrigation; fertilizer application).

  13. A research of a high precision multichannel data acquisition system

    NASA Astrophysics Data System (ADS)

    Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei

    2013-08-01

    The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.

  14. High-Precision Measurements of the Brightness Variation of Nereid

    NASA Astrophysics Data System (ADS)

    Terai, Tsuyoshi; Itoh, Yoichi

    2013-04-01

    Nereid, the outer satellite of Neptune, has a highly eccentric prograde orbit with a semimajor axis of larger than 200 in units of Neptune's radius, and is classified as an irregular satellite. Although the capture origin of irregular satellites has been widely accepted, several previous studies suggest that Nereid was formed in the circumplanetary disk of Neptune and ejected outward to the present location by Triton. A series of our photometric observations confirm that Nereid's rotation period, 11.5 hr, is stable and nonchaotic, as indicated by Grav, Holman, and Kavelaars (2003, ApJ, 591, L71). The optical colors of Nereid are indistinguishable from those of trans-Neptunian objects and Centaurs, especially from these objects with neutral colors. We also found the consistency of Nereid's rotation period based on the size-rotation distribution of small outer bodies. It is likely that Nereid originated as an immigrant body captured from the heliocentric orbit that was 4-5 AU away from Neptune's orbit.

  15. High Resolution Airborne Digital Imagery for Precision Agriculture

    NASA Technical Reports Server (NTRS)

    Herwitz, Stanley R.

    1998-01-01

    The Environmental Research Aircraft and Sensor Technology (ERAST) program is a NASA initiative that seeks to demonstrate the application of cost-effective aircraft and sensor technology to private commercial ventures. In 1997-98, a series of flight-demonstrations and image acquisition efforts were conducted over the Hawaiian Islands using a remotely-piloted solar- powered platform (Pathfinder) and a fixed-wing piloted aircraft (Navajo) equipped with a Kodak DCS450 CIR (color infrared) digital camera. As an ERAST Science Team Member, I defined a set of flight lines over the largest coffee plantation in Hawaii: the Kauai Coffee Company's 4,000 acre Koloa Estate. Past studies have demonstrated the applications of airborne digital imaging to agricultural management. Few studies have examined the usefulness of high resolution airborne multispectral imagery with 10 cm pixel sizes. The Kodak digital camera integrated with ERAST's Airborne Real Time Imaging System (ARTIS) which generated multiband CCD images consisting of 6 x 106 pixel elements. At the designated flight altitude of 1,000 feet over the coffee plantation, pixel size was 10 cm. The study involved the analysis of imagery acquired on 5 March 1998 for the detection of anomalous reflectance values and for the definition of spectral signatures as indicators of tree vigor and treatment effectiveness (e.g., drip irrigation; fertilizer application).

  16. Method of reforming gasoline to raise the octane thereof utilizing low valence chromium composited with non-oxidizing high surface area support

    SciTech Connect

    Gleim, W.K.T.

    1984-05-15

    This invention relates to a method of reforming gasoline to raise the octane number thereof utilizing a novel catalyst comprising a low valence chromium metallic component composited with a non-oxidizing high surface area support. The low valence metallic component is present in divalent form or as a combination of the metallic state and the divalent form-preferably as a chloride and/or bromide. The preferred support is a high surface area coke.

  17. High Precision Cosmology with the Cosmic Background Radiation

    NASA Astrophysics Data System (ADS)

    Farhang, Marzieh

    around the fiducial model of the standard recombination scenario. Though theoretically well studied, the detailed assumptions in the recombination history, based on standard atomic physics, have never been directly tested. However, for our CMB-based cosmological inferences to be reliable, the recombination scenario needs to be observationally verified. We approach this problem in a model-independent way and construct rank-ordered parameter eigen-modes with the highest power to probe Xe. We study various properties of these modes, including their convergence, fiducial model-dependence, dataset dependence, and the eigen-modes response to marginalization over different standard parameters. We demonstrate that, if enough modes are included, the eigen-modes form a practically complete set of basis function for expanding different physically motivated Xe perturbations. We also develop an information-based criterion to truncate the eigen-mode hierarchy, which can be used in similar hierarchical model selections as well. We show how our measurements of cosmic parameters will be affected if possible deviations in the recombination history are ignored. The method is applied to simulations of Planck+ACTPol and a cosmic variance limited survey with differing simulated recombination histories and the recovered Xe trajectories are constructed. We also apply the method to the best currently available CMB datasets, WMAP9+ACT/SPT. The first constructed eigen-mode turns out to be a direct measure of the damping envelope. Its current measurement with SPT slightly indicates a damping tail anomaly, while ACT data agree well with the standard scenario. High resolution Planck data will resolve this tension with high significance.

  18. Influence of nitrogen admixture to argon on the ion energy distribution in reactive high power pulsed magnetron sputtering of chromium

    NASA Astrophysics Data System (ADS)

    Breilmann, W.; Maszl, C.; Hecimovic, A.; von Keudell, A.

    2017-04-01

    Reactive high power impulse magnetron sputtering (HiPIMS) of metals is of paramount importance for the deposition of various oxides, nitrides and carbides. The addition of a reactive gas such as nitrogen to an argon HiPIMS plasma with a metal target allows the formation of the corresponding metal nitride on the substrate. The addition of a reactive gas introduces new dynamics into the plasma process, such as hysteresis, target poisoning and the rarefaction of two different plasma gases. We investigate the dynamics for the deposition of chromium nitride by a reactive HiPIMS plasma using energy- and time-resolved ion mass spectrometry, fast camera measurements and temporal and spatially resolved optical emission spectroscopy. It is shown that the addition of nitrogen to the argon plasma gas significantly changes the appearance of the localized ionization zones, the so-called spokes, in HiPIMS plasmas. In addition, a very strong modulation of the metal ion flux within each HiPIMS pulse is observed, with the metal ion flux being strongly suppressed and the nitrogen molecular ion flux being strongly enhanced in the high current phase of the pulse. This behavior is explained by a stronger return effect of the sputtered metal ions in the dense plasma above the racetrack. This is best observed in a pure nitrogen plasma, because the ionization zones are mostly confined, implying a very high local plasma density and consequently also an efficient scattering process.

  19. High Precision Pulsar Timing: Effects of ISM Correction Schemes

    NASA Astrophysics Data System (ADS)

    Kunert, Willie; Verbiest, J. P. W.; Shannon, R.; Stinebring, D.

    2012-01-01

    Pulsar timing arrays are one of the leading methods in the search for gravitational waves (GWs). However a significant issue facing this method is the effect of the interstellar medium (ISM). There are multiple methodologies being used to correct for these effects but their efficacy has not been carefully studied. We conducted an initial study of biases induced by correcting for the interstellar medium. We simulated times of arrival (TOAs) with white noise and added ISM delays. We measure the ISM effects as is done with normal data, and created a model of these effects using polynomial fitting. This modeling method is most commonly used in the European Pulsar Timing Array. We then remove these measured ISM effects and compare final and initial TOAs. Ideally they should be the same; however, the differences between the 'corrected' TOAs and original TOAs reveal the weaknesses of this method. In preliminary results we concluded that the higher order polynomials do a better job, yet there is a limit as to how high an order one can use. We also found no significant systematic parameter bias induced by using this method. However, it is clear that certain parameters are more affected by this process of correction. The parameters most affected were the frequency and frequency derivative of the pulsar, but biases in these parameters are not important because the power due to them gets removed in the standard timing analysis. We are continuing this research by comparing and contrasting ISM correction schemes, as well as studying the actual behavior of the ISM in more detail. This research is supported by an NSF-PIRE and an NSF-AST grant.

  20. Flexible head-casts for high spatial precision MEG.

    PubMed

    Meyer, Sofie S; Bonaiuto, James; Lim, Mark; Rossiter, Holly; Waters, Sheena; Bradbury, David; Bestmann, Sven; Brookes, Matthew; Callaghan, Martina F; Weiskopf, Nikolaus; Barnes, Gareth R

    2017-01-30

    In combination with magnetoencephalographic (MEG) data, accurate knowledge of the brain's structure and location provide a principled way of reconstructing neural activity with high temporal resolution. However, measuring the brain's location is compromised by head movement during scanning, and by fiducial-based co-registration with magnetic resonance imaging (MRI) data. The uncertainty from these two factors introduces errors into the forward model and limit the spatial resolution of the data. We present a method for stabilizing and reliably repositioning the head during scanning, and for co-registering MRI and MEG data with low error. Using this new flexible and comfortable subject-specific head-cast prototype, we find within-session movements of <0.25mm and between-session repositioning errors around 1mm. This method is an improvement over existing methods for stabilizing the head or correcting for location shifts on- or off-line, which still introduce approximately 5mm of uncertainty at best (Adjamian et al., 2004; Stolk et al., 2013; Whalen et al., 2008). Further, the head-cast design presented here is more comfortable, safer, and easier to use than the earlier 3D printed prototype, and give slightly lower co-registration errors (Troebinger et al., 2014b). We provide an empirical example of how these head-casts impact on source level reproducibility. Employment of the individual flexible head-casts for MEG recordings provide a reliable method of safely stabilizing the head during MEG recordings, and for co-registering MRI anatomical images to MEG functional data. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  1. Small Scale Landscape Evolution: Rainfall Simulations On High Precision Dtms

    NASA Astrophysics Data System (ADS)

    Catani, F.; Moretti, S.

    Processes characterizing the evolution of relief have recently been recognized as hav- ing scaling properties both in their physical behavior and in their effects on the shape of landscape. Sophisticated evolutionary models have been devised so far, which takes also into account fractal properties, self-similarity and self-organized criticality, espe- cially in the organization of river networks inside catchments. Despite these efforts, which are generally successful from a theoretical point of view, few attempts have been made to actually test these hypotheses in the field. This is due mainly to the dif- ficulties connected with the practical realization of suitable physical models as well as with the problem of the time scale of such processes when dealing with whole river basins. This paper, that presents experimental data on the geometric and morphometric evolution of small scale soil parcels after simulated cycles of rainfall, could contribute to partially fill this gap giving insight on the spatial patterns of newly formed valleys and ridges as well as on the most stable geomorphological configurations. Starting from chosen parcels on crops or bare soils in central Italy, rainfall simulations have been undertaken over repeating cycles of storms. At the beginning of the experiment and after each event, a high resolution DTM of the parcel was automatically generated by means of a recently developed digital stereo-photogrammetric ground-based tech- nique. At the same time, sediment yield and runoff were measured. All the studied parcels were initially characterized by the absence of an internal channel system. Ini- tial topographies could basically be considered as random space functions with quasi- isotropic distribution of the elevations. Each DTM sequence can thus be regarded as an example of channel building process, from sheet flow erosion to the convergence and intersection of small flows to the full development of the surface, with a system of valleys and

  2. Spectral Unmixing Plate Reader: High-Throughput, High-Precision FRET Assays in Living Cells.

    PubMed

    Schaaf, Tory M; Peterson, Kurt C; Grant, Benjamin D; Thomas, David D; Gillispie, Gregory D

    2017-03-01

    We have developed a microplate reader that records a complete high-quality fluorescence emission spectrum on a well-by-well basis under true high-throughput screening (HTS) conditions. The read time for an entire 384-well plate is less than 3 min. This instrument is particularly well suited for assays based on fluorescence resonance energy transfer (FRET). Intramolecular protein biosensors with genetically encoded green fluorescent protein (GFP) donor and red fluorescent protein (RFP) acceptor tags at positions sensitive to structural changes were stably expressed and studied in living HEK cells. Accurate quantitation of FRET was achieved by decomposing each observed spectrum into a linear combination of four component (basis) spectra (GFP emission, RFP emission, water Raman, and cell autofluorescence). Excitation and detection are both conducted from the top, allowing for thermoelectric control of the sample temperature from below. This spectral unmixing plate reader (SUPR) delivers an unprecedented combination of speed, precision, and accuracy for studying ensemble-averaged FRET in living cells. It complements our previously reported fluorescence lifetime plate reader, which offers the feature of resolving multiple FRET populations within the ensemble. The combination of these two direct waveform-recording technologies greatly enhances the precision and information content for HTS in drug discovery.

  3. Development of compact high precision linear piezoelectric stepping positioner with nanometer accuracy and large travel range.

    PubMed

    Kang, Dongwoo; Lee, Moon G; Gweon, Daegab

    2007-07-01

    Many application areas such as semiconductor manufacture, precision optics alignment, and microbiological cell manipulation require ultraprecision positioning systems with a high positioning resolution and large motion range. This article describes the development of a compact high precision linear piezoelectric stepping positioner for precision alignment of optical elements. The positioner is designed to have a compact and symmetric structure, high positioning resolution, large motion range, high force density, adequate dynamic range, and power-off hold. The positioner is fabricated according to these specifications and performance evaluation tests are carried out. A resolution of 10 nm, speed of 1 mms, push force of 25 N, and stiffness of 10.4 N/microm are attained while maintaining a compact size of 32x42x60 mm(3). The required power consumption is 52.33 W. The test results confirm that the developed positioner could be successfully applied to the precision alignment of optical elements.

  4. Chromium-induced skin damage among Taiwanese cement workers.

    PubMed

    Chou, Tzu-Chieh; Wang, Po-Chih; Wu, Jyun-De; Sheu, Shiann-Cherng

    2016-10-01

    Little research has been done on the relationships between chromium exposure, skin barrier function, and other hygienic habits in cement workers. Our purpose was to investigate chromium-induced skin barrier disruption due to cement exposure among cement workers. One hundred and eight cement workers were recruited in this study. Urinary chromium concentration was used to characterize exposure levels. The biological exposure index was used to separate high and low chromium exposure. Transepidermal water loss (TEWL) was used to assess the skin barrier function. TEWL was significantly increased in workers with high chromium exposure levels than those with low chromium exposure levels (p = 0.048). A positive correlation was also found between urinary chromium concentration and TEWL (R = 0.28, p = 0.004). After adjusting for smoking status and glove use, a significant correlation between urinary chromium concentrations and TEWL remained. Moreover, workers who smoked and had a high chromium exposure had significantly increased TEWL compared to nonsmokers with low chromium exposure (p = 0.01). Skin barrier function of cement workers may have been disrupted by chromium in cement, and smoking might significantly enhance such skin barrier perturbation with chromium exposure. Decreased chromium skin exposure and smoking cessation should be encouraged at work. © The Author(s) 2015.

  5. [Is chromium an essential trace element in human nutrition?].

    PubMed

    Yoshida, Munehiro

    2012-01-01

    It has been recognized that chromium is an essential trace element associated with carbohydrate metabolism, and chromium deficiency causes an impaired glucose tolerance. Recently, however, Vincent et al. have reported that chromium is not an essential trace element. In the present report, the author evaluated the nutritional essentiality of chromium by reviewing several previous reports. In almost all previous reports, the chromium concentration in the animal feed used was higher than 0.1 μg/g, and it is difficult to consider that the experimental animals were in a low-chromium state. In addition, the amount of chromium administered to the animals for the improvement of glucose tolerance was at a pharmacological level, and corresponded to a level that far exceeded the human daily chromium intake (20 to 80 μg/day). On the other hand, recent research has clearly shown that feeding with a severely low-chromium diet (0.016 μg/g) does not impair glucose tolerance. The amount of chromium absorbed in humans estimated from chromium intake (20 to 80 μg/day), chromium absorption rate (1%), and urinary chromium excretion (<1 μg/day) is less than 1 μg/day, which is much lower than those of other essential trace elements. In addition, because there is an inconsistency between the chromium concentration in food and chromium intake, chromium intake seems to be dependent on chromium contamination during food processing and cooking. It is concluded that there is a high possibility that chromium is not an essential trace element.

  6. Solvent-Assisted Metal Metathesis: A Highly Efficient and Versatile Route towards Synthetically Demanding Chromium Metal-Organic Frameworks.

    PubMed

    Wang, Jun-Hao; Zhang, Ying; Li, Mian; Yan, Shu; Li, Dan; Zhang, Xian-Ming

    2017-06-01

    Chromium(III)-based metal-organic frameworks (Cr-MOFs) are very attractive in a wide range of investigations because of their robustness and high porosity. However, reports on Cr-MOFs are scarce owing to the difficulties in their direct synthesis. Recently developed postsynthetic routes to obtain Cr-MOFs suffered from complicated procedures and a lack of general applicability. Herein, we report a highly efficient and versatile strategy, namely solvent-assisted metal metathesis, to obtain Cr-MOFs from a variety of Fe(III) -MOFs, including several well-known MOFs and a newly synthesized one, through judicious selection of a coordinating solvent. The versatility of this strategy was demonstrated by producing Cr-MIL-100, Cr-MIL-142A/C, Cr-PCN-333, and Cr-PCN-600 from their Fe(III) analogues and Cr-SXU-1 from a newly synthesized MOF precursor, Fe-SXU-1, in acetone as the solvent under very mild conditions. We have thus developed a general approach for the preparation of robust Cr-MOFs, which are difficult to synthesize by direct methods. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Root uptake and reduction of hexavalent chromium by aquatic macrophytes as assessed by high-resolution X-ray emission.

    PubMed

    Espinoza-Quiñones, Fernando R; Martin, Neiva; Stutz, Guillermo; Tirao, German; Palácio, Soraya M; Rizzutto, Márcia A; Módenes, Aparecido N; Silva, Fernando G; Szymanski, Nayara; Kroumov, Alexander D

    2009-09-01

    Aquatic macrophytes Salvinia auriculata, Pistia stratiotes and Eichhornia crassipes were chosen to investigate the Cr(VI) reduced by root-based biosorption in a chromium uptake experiment, using a high-resolution XRF technique. These plants were grown in hydroponics medium supplied with non-toxic Cr concentrations during a 27-day metal uptake experiment. The high-resolution Cr-Kbeta fluorescence spectra for dried root tissues and Cr reference material (100% Cr, Cr(2)O(3), and CrO(3)) were measured using an XRF spectrometer. For all species of aquatic plant treated with Cr(VI), the energy of the Cr-Kbeta(2,5) line was shifted around 8 eV below the same spectral line identified for the Cr(VI) reference, but it was also near to the line identified for the Cr(III) reference. Moreover, there was a lack of the strong Cr-Kbeta'' line assigned to the Cr(VI) reference material within the Cr(VI)-treated plant spectra, suggesting the reduction of Cr(VI) for other less toxic oxidation states of Cr. As all Cr-Kbeta spectra of root tissue species were compared, the peak energies and lineshape patterns of the Cr-Kbeta(2,5) line are coincident for the same aquatic plant species, when they were treated with Cr(III) and Cr(VI). Based on the experimental evidence, the Cr(VI) reduction process has happened during metal biosorption by these plants.

  8. High-pressure structural phase transitions in chromium-doped BaFe[subscript 2]As[subscript 2

    SciTech Connect

    Uhoya, W.O.; Montgomery, J.M.; Samudrala, G.K.; Tsoi, G.M.; Vohra, Y.K.; Weir, S.T.; Sefat, A.S.

    2012-10-23

    We report on the results from high pressure x-ray powder diffraction and electrical resistance measurements for hole doped BaFe{sub 2-x}Cr{sub x}As{sub 2} (x = 0, 0.05, 0.15, 0.4, 0.61) up to 81 GPa and down to 10 K using a synchrotron source and diamond anvil cell (DAC). At ambient temperature, an isostructural phase transition from a tetragonal (T) phase (I4/mmm) to a collapsed tetragonal (CT) phase is observed at 17 GPa. This transition is found to be dependent on ambient pressure unit cell volume and is slightly shifted to higher pressure upon increase in the Cr-doping. Unlike BaFe{sub 2}As{sub 2} which superconduct under high pressure, we have not detected any evidence of pressure induced superconductivity in chromium doped samples in the pressure and temperature range of this study. The measured equation of state parameters are presented for both the tetragonal and collapsed tetragonal phases for x = 0.05, 0.15, 0.40 and 0.61.

  9. Research on the high-precision non-contact optical detection technology for banknotes

    NASA Astrophysics Data System (ADS)

    Jin, Xiaofeng; Liang, Tiancai; Luo, Pengfeng; Sun, Jianfeng

    2015-09-01

    The technology of high-precision laser interferometry was introduced for optical measurement of the banknotes in this paper. Taking advantage of laser short wavelength and high sensitivity, information of adhesive tape and cavity about the banknotes could be checked efficiently. Compared with current measurement devices, including mechanical wheel measurement device, Infrared measurement device, ultrasonic measurement device, the laser interferometry measurement has higher precision and reliability. This will improve the ability of banknotes feature information in financial electronic equipment.

  10. Research on high acceleration high precision air suspension control system performance evaluation algorithm

    NASA Astrophysics Data System (ADS)

    Ling, Xiang; Zhang, Yu

    2017-07-01

    The motion performance of the high acceleration high precision air suspension platform is affected by the electromechanical characteristics of the drive system, the fluid characteristics of the air suspension guide rail and the load disturbance. The mathematical model of the system is established, and the controller performance is designed based on the optimal objective function value. The ideal controller performance is proposed as the evaluation benchmark. The performance of the system is evaluated by the ratio of the optimal objective value and the evaluation benchmark. Based on the established evaluation index, the influence of noise disturbance and estimation vector on the stability and robustness of the system is evaluated, and the system performance is further optimized.

  11. SOLARIS 3-axis high load, low profile, high precision motorized positioner

    SciTech Connect

    Acome, Eric; Van Every, Eric; Deyhim, Alex; Zajac, Marcin

    2016-07-27

    A 3-axis optical table, shown in Figure 1, was designed, fabricated, and assembled for the SOLARIS synchrotron facility at the Jagiellonian University in Krakow, Poland. To accommodate the facility, the table was designed to be very low profile, as seen in Figure 2, and bear a high load. The platform has degrees of freedom in the vertical (Z) direction as well as horizontal transversal (X and Y) directions. The table is intended to sustain loads as large as 1500 kg which will be sufficient to support a variety of equipment to measure and facilitate synchrotron radiation. After assembly, the table was tested and calibrated to find its position error in the vertical direction. ADC has extensive experience designing and building custom complex high precision motion systems [1,2].

  12. Charge Breeding Techniques in an Electron Beam Ion Trap for High Precision Mass Spectrometry at TITAN

    NASA Astrophysics Data System (ADS)

    MacDonald, T. D.; Simon, M. C.; Bale, J. C.; Chowdhury, U.; Eibach, M.; Gallant, A. T.; Lennarz, A.; Simon, V. V.; Chaudhuri, A.; Grossheim, A.; Kwiatkowski, A. A.; Schultz, B. E.; Dilling, J.

    2012-10-01

    Penning trap mass spectrometry is the most accurate and precise method available for performing atomic mass measurements. TRIUMF's Ion Trap for Atomic and Nuclear science is currently the only facility to couple its Penning trap to a rare isotope facility and an electron beam ion trap (EBIT). The EBIT is a valuable tool for beam preparation: since the precision scales linearly with the charge state, it takes advantage of the precision gained by using highly charged ions. However, this precision gain is contingent on fast and efficient charge breeding. An optimization algorithm has been developed to identify the optimal conditions for running the EBIT. Taking only the mass number and half-life of the isotope of interest as inputs, the electron beam current density, charge breeding time, charge state, and electron beam energy are all specified to maximize this precision. An overview of the TITAN charge breeding program, and the results of charge breeding simulations will be presented.

  13. New tools for high-precision positioning of optical elements in high-NA microscope objectives

    NASA Astrophysics Data System (ADS)

    Heil, Joachim; Bauer, Tobias; Mueller, Willi; Sure, Thomas; Wesner, Joachim

    2004-02-01

    The precise positioning of the individual optical elements is essential for attaining diffraction limited performance in high-numerical-aperture (high-NA) microscope objectives. Tolerances are in the micron range or lower for high-end objectives, e.g. for broad-band scanning confocal applications, metrology objectives in general, and especially for deep ultraviolet (DUV) applications. The ever increasing demands on imaging performance ask for the continuous development and improvement of specialized measurement equipment for the production line. Our award-winning 150x/0.90-DUV-AT-infinity/0 objective for wafer inspection and metrology at 248nm employs air spacings in its doublets because of the instability of optical cements against DUV radiation. This comes however at the cost of a higher number of surfaces and even higher precision demands on their geometry, orientation and positioning. We present several tools enabling us to meet these requirements. A Fourier transform fringe analysis scheme is adapted to high-NA Fizeau interferometry for surface characterization. A white light Mirau interferometer for dimensional measurements on lens groups with sub-μm resolution enables us to keep surface distance errors lower than 2 μm. Residual aberrations of the objective are compensated for by translating special correction elements under observation of the wave-front using a DUV-Twyman-Green interferometer, which also incorporates a 903nm branch for the parfocal adjustment of the infrared (IR) autofocus feature of the objective. To adjust the shifting element for the elimination of on-axis coma, we compute an artificial (real-time) star test from the interferogram, allowing interactive manipulations of the element while monitoring their influence on the point spread function (PSF).

  14. Research on high-precision hole measurement based on robot vision method

    NASA Astrophysics Data System (ADS)

    Song, Li-mei; Li, Da-peng; Qin, Ming-cui; Li, Zong-yan; Chang, Yu-lan; Xi, Jiang-tao

    2014-09-01

    A high-precision vision detection and measurement system using mobile robot is established for the industry field detection of motorcycle frame hole and its diameter measurement. The robot path planning method is researched, and the non-contact measurement method with high precision based on visual digital image edge extraction and hole spatial circle fitting is presented. The Canny operator is used to extract the edge of captured image, the Lagrange interpolation algorithm is utilized to determine the missing image edge points and calculate the centroid, and the least squares fitting method is adopted to fit the image edge points. Experimental results show that the system can be used for the high-precision real-time measurement of hole on motorcycle frame. The absolute standard deviation of the proposed method is 0.026 7 mm. The proposed method can not only improve the measurement speed and precision, but also reduce the measurement error.

  15. Microstructure and surface properties of chromium-doped diamond-like carbon thin films fabricated by high power pulsed magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Wu, Zhongzhen; Tian, Xiubo; Gui, Gang; Gong, Chunzhi; Yang, Shiqin; Chu, Paul K.

    2013-07-01

    High power pulsed magnetron sputtering (HPPMS) has attracted much interest due to the large plasma density and high ionization rate of sputtered materials. It is expected to produce a highly ionized C flux from a graphite target but unfortunately, the ionization rate of carbon is still very small and the discharge on a solid carbon target is unstable as well. In this work, a stable discharged chromium target is used in the preparation of chromium-doped diamond-like carbon (Cr-DLC) films in HPPMS in reactive C2H2 gas, but the unstable graphite. The chromium concentration in the Cr-DLC films is limited by surface poisoning due to reactive gas. Less than 2% of Cr is incorporated into the DLC films at C2H2 flow rate of 5 sccm or higher. However, as a result of the high ionization rate of the reactive gas in HPPMS, intense ion bombardment of the substrate is realized. The films show a smooth surface and a dense structure with a large sp3 concentration. As the C2H2 flow increase, the sp3 fraction increase and the sp3 to sp2 ratio increase to 0.75 at a C2H2 flow rate of 10 sccm. Compared to the substrate, the Cr-DLC films have lower friction and exhibit excellent corrosion resistance.

  16. Classification of LIDAR Data for Generating a High-Precision Roadway Map

    NASA Astrophysics Data System (ADS)

    Jeong, J.; Lee, I.

    2016-06-01

    Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  17. Influence of chromium on the mechanical properties and microstructure of weld metal from a high-strength SMA electrode

    SciTech Connect

    Surian, E.; Trotti, J. ); Cassanelli, A. ); Vedia, L.A. De )

    1994-03-01

    In the present work, the influence of Cr on mechanical properties and microstructure of weld metal from a high-strength SMA electrode is analyzed by considering 12 experimental low-alloy low-hydrogen iron powder AWS E10018, E11018, E12018-M type covered electrodes. These electrodes were manufactured to obtain in the weld deposits Cr contents ranging from 0 to 1.8%, with two different Mn levels for each Cr content, maintaining the amount of other elements at a fixed value. All-weld-metal specimens and production type single V-groove welds were mechanically tested in the as-welded and stress-relieved conditions, and a metallographic study was conducted. Chromium was found to be deleterious to toughness with only a minor influence due to Mn variations. A postweld heat treatment led in all cases to a reduction of toughness. Increasing Cr content in the welds produced a higher proportion of acicular ferrite and a general refinement of the microstructure.

  18. Chromium Reaction Mechanisms for Speciation using Synchrotron in-Situ High-Temperature X-ray Diffraction.

    PubMed

    Low, Fiona; Kimpton, Justin; Wilson, Siobhan A; Zhang, Lian

    2015-07-07

    We use in situ high-temperature X-ray diffraction (HT-XRD), ex-situ XRD and synchrotron X-ray absorption near edge structure spectroscopy (XANES) to derive fundamental insights into mechanisms of chromium oxidation during combustion of solid fuels. To mimic the real combustion environment, mixtures of pure eskolaite (Cr(3+)2O3), lime (CaO) and/or kaolinite [Al2Si2O5(OH)4] have been annealed at 600-1200 °C in air versus 1% O2 diluted by N2. Our results confirm for the first time that (1) the optimum temperature for Cr(6+) formation is 800 °C for the coexistence of lime and eskolaite; (2) upon addition of kaolinite into oxide mixture, the temperature required to produce chromatite shifts to 1000 °C with a remarkable reduction in the fraction of Cr(6+). Beyond 1000 °C, transient phases are formed that bear Cr in intermediate valence states, which convert to different species other than Cr(6+) in the cooling stage; (3) of significance to Cr mobility from the waste products generated by combustion, chromatite formed at >1000 °C has a glassy disposition that prevents its water-based leaching; and (4) Increasing temperature facilitates the migration of eskolaite particles into bulk lime and enhances the extent to which Cr(3+) is oxidized, thereby completing the oxidation of Cr(3+) to Cr(6+) within 10 min.

  19. Suppressing the chromium disproportionation reaction in O3-type layered cathode materials for high capacity sodium-ion batteries

    DOE PAGES

    Cao, Ming -Hui; Wang, Yong; Shadike, Zulipiya; ...

    2017-02-14

    Chromium-based layered cathode materials suffer from the irreversible disproportionation reaction of Cr4+ to Cr3+ and Cr6+, which hinders the reversible multi-electron redox of Cr ions in layered cathodes, and limits their capacity and reversibility. To address this problem, a novel O3-type layer-structured transition metal oxide of NaCr1/3Fe1/3Mn1/3O2 (NCFM) was designed and studied as a cathode material. A high reversible capacity of 186 mA h g–1 was achieved at a current rate of 0.05C in a voltage range of 1.5 to 4.2 V. X-ray diffraction revealed an O3 → (O3 + P3) → (P3 + O3'') → O3'' phase-transition pathway formore » NCFM during charge. X-ray absorption, X-ray photoelectron and electron energy-loss spectroscopy measurements revealed the electronic structure changes of NCFM during Na+ deintercalation/intercalation processes. It is confirmed that the disproportionation reaction of Cr4+ to Cr3+ and Cr6+ can be effectively suppressed by Fe3+ and Mn4+ substitution. Lastly, these results demonstrated that the reversible multi-electron oxidation/reduction of Cr ions can be achieved in NCFM during charge and discharge accompanied by CrO6 octahedral distortion and recovery.« less

  20. Suppressing the chromium disproportionation reaction in O3-type layered cathode materials for high capacity sodium-ion batteries

    SciTech Connect

    Cao, Ming-Hui; Wang, Yong; Shadike, Zulipiya; Yue, Ji-Li; Hu, Enyuan; Bak, Seong-Min; Zhou, Yong-Ning; Yang, Xiao-Qing; Fu, Zheng-Wen

    2017-01-01

    Chromium-based layered cathode materials suffer from the irreversible disproportionation reaction of Cr4+ to Cr3+ and Cr6+, which hinders the reversible multi-electron redox of Cr ions in layered cathodes, and limits their capacity and reversibility. To address this problem, a novel O3-type layer-structured transition metal oxide of NaCr1/3Fe1/3Mn1/3O2 (NCFM) was designed and studied as a cathode material. A high reversible capacity of 186 mA h g-1 was achieved at a current rate of 0.05C in a voltage range of 1.5 to 4.2 V. X-ray diffraction revealed an O3 → (O3 + P3) → (P3 + O3'') → O3'' phase-transition pathway for NCFM during charge. X-ray absorption, X-ray photoelectron and electron energy-loss spectroscopy measurements revealed the electronic structure changes of NCFM during Na+ deintercalation/intercalation processes. It is confirmed that the disproportionation reaction of Cr4+ to Cr3+ and Cr6+ can be effectively suppressed by Fe3+ and Mn4+ substitution. These results demonstrated that the reversible multi-electron oxidation/reduction of Cr ions can be achieved in NCFM during charge and discharge accompanied by CrO6 octahedral distortion and recovery.

  1. Speciation of chromium in environmental samples by dual electromembrane extraction system followed by high performance liquid chromatography.

    PubMed

    Safari, Meysam; Nojavan, Saeed; Davarani, Saied Saeed Hosseiny; Morteza-Najarian, Amin

    2013-07-30

    This study proposes the dual electromembrane extraction followed by high performance liquid chromatography for selective separation-preconcentration of Cr(VI) and Cr(III) in different environmental samples. The method was based on the electrokinetic migration of chromium species toward the electrodes with opposite charge into the two different hollow fibers. The extractant was then complexed with ammonium pyrrolidinedithiocarbamate for HPLC analysis. The effects of analytical parameters including pH, type of organic solvent, sample volume, stirring rate, time of extraction and applied voltage were investigated. The results showed that Cr(III) and Cr(VI) could be simultaneously extracted into the two different hollow fibers. Under optimized conditions, the analytes were quantified by HPLC instrument, with acceptable linearity ranging from 20 to 500 μg L(-1) (R(2) values≥0.9979), and repeatability (RSD) ranging between 9.8% and 13.7% (n=5). Also, preconcentration factors of 21.8-33 that corresponded to recoveries ranging from 31.1% to 47.2% were achieved for Cr(III) and Cr(VI), respectively. The estimated detection limits (S/N ratio of 3:1) were less than 5.4 μg L(-1). Finally, the proposed method was successfully applied to determine Cr(III) and Cr(VI) species in some real water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Swelling Behavior of High-Chromium, Vanadium-Bearing Titanomagnetite Pellets in H2-CO-CO2 Gas Mixtures

    NASA Astrophysics Data System (ADS)

    Li, F.; Chu, M. S.; Tang, J.; Liu, Z. G.; Feng, C.; Tang, Y. T.

    2017-10-01

    In this study, the effects of temperature, gas composition and reduction degree on the reduction swelling index (RSI) of high-chromium vanadium-bearing titanomagnetite (HCVT) pellets during reduction with H2-CO-CO2 gas mixtures are investigated. The results show that the formation of massive wüstite causes most of the volume expansion of the pellets. The swelling of HCVT pellets is intensified with the temperature and content of CO, and the RSI reaches a maximum at the reduction degree of 35-50%. In H2/CO = 5/2 (volume ratio) with a temperature range from 1223 K to 1373 K, the maximum RSI increases from 14.68% to 22.54%. Nevertheless, when the ratio of H2/CO increases from 2/5 to 5/2 at 1223 K, the maximum RSI of the pellets decreases from 21.25% to 19.55%. Meanwhile, the shrinking rate of the pellets also decreases from 33.20% to 27.26%.

  3. Reduction mechanism of high-chromium vanadium-titanium magnetite pellets by H2-CO-CO2 gas mixtures

    NASA Astrophysics Data System (ADS)

    Tang, Jue; Chu, Man-sheng; Li, Feng; Tang, Ya-ting; Liu, Zheng-gen; Xue, Xiang-xin

    2015-06-01

    The reduction of high-chromium vanadium-titanium magnetite as a typical titanomagnetite containing 0.95wt% V2O5 and 0.61wt% Cr2O3 by H2-CO-CO2 gas mixtures was investigated from 1223 to 1373 K. Both the reduction degree and reduction rate increase with increasing temperature and increasing hydrogen content. At a temperature of 1373 K, an H2/CO ratio of 5/2 by volume, and a reduction time of 40 min, the degree of reduction reaches 95%. The phase transformation during reduction is hypothesized to proceed as follows: Fe2O3 → Fe3O4 → FeO → Fe; Fe9TiO15 + Fe2Ti3O9 → Fe2.75Ti0.25O4 → FeTiO3 → TiO2; (Cr0.15V0.85)2O3 → Fe2VO4; and Cr1.3Fe0.7O3 → FeCr2O4. The reduction is controlled by the mixed internal diffusion and interfacial reaction at the initial stage; however, the interfacial reaction is dominant. As the reduction proceeds, the internal diffusion becomes the controlling step.

  4. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.

    PubMed

    Fritz, Jan; Ahlawat, Shivani; Demehri, Shadpour; Thawait, Gaurav K; Raithel, Esther; Gilson, Wesley D; Nittka, Mathias

    2016-10-01

    The aim of this study was to prospectively test the hypothesis that a compressed sensing-based slice encoding for metal artifact correction (SEMAC) turbo spin echo (TSE) pulse sequence prototype facilitates high-resolution metal artifact reduction magnetic resonance imaging (MRI) of cobalt-chromium knee arthroplasty implants within acquisition times of less than 5 minutes, thereby yielding better image quality than high-bandwidth (BW) TSE of similar length and similar image quality than lengthier SEMAC standard of reference pulse sequences. This prospective study was approved by our institutional review board. Twenty asymptomatic subjects (12 men, 8 women; mean age, 56 years; age range, 44-82 years) with total knee arthroplasty implants underwent MRI of the knee using a commercially available, clinical 1.5 T MRI system. Two compressed sensing-accelerated SEMAC prototype pulse sequences with 8-fold undersampling and acquisition times of approximately 5 minutes each were compared with commercially available high-BW and SEMAC pulse sequences with acquisition times of approximately 5 minutes and 11 minutes, respectively. For each pulse sequence type, sagittal intermediate-weighted (TR, 3750-4120 milliseconds; TE, 26-28 milliseconds; voxel size, 0.5 × 0.5 × 3 mm) and short tau inversion recovery (TR, 4010 milliseconds; TE, 5.2-7.5 milliseconds; voxel size, 0.8 × 0.8 × 4 mm) were acquired. Outcome variables included image quality, display of the bone-implant interfaces and pertinent knee structures, artifact size, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Statistical analysis included Friedman, repeated measures analysis of variances, and Cohen weighted k tests. Bonferroni-corrected P values of 0.005 and less were considered statistically significant. Image quality, bone-implant interfaces, anatomic structures, artifact size, SNR, and CNR parameters were statistically similar between the compressed sensing-accelerated SEMAC prototype and SEMAC

  5. A rugged, high precision capacitance diaphragm low pressure gauge for cryogenic use

    NASA Astrophysics Data System (ADS)

    Lago, Leatitia; Herbeaux, Christian; Bol, Marc; Roy, Pascale; Manceron, Laurent

    2014-01-01

    In order to carry out precise laboratory measurements of infrared absorption intensities, line profiles of molecules and organic volatile compounds for atmospheric chemistry in planetary and upper earth atmospheric layers, precise gas pressure measurement between 10-3 and a few mbars in the 77-300 K temperature range is necessary. A prototype, rugged, precision capacitive pressure gauge for cryogenic use has been designed, built at SOLEIL and tested down to 77 K. The design includes corrosion-resistant materials and has been tailored to operate on a differential measurement scheme based on a simple, precision capacitance-to-digital converter chip, instead of high precision floating capacitive bridges, as are used in other designs. The designs conception and performance specifications are presented here, illustrated by a precision of better than 1% in the 0.2-40 mbar range, with a resolution of 2 × 10-3 mbar. The gauge is tunable and can be adjusted for higher precision and a better resolution, at the expense of the maximum high-pressure range.

  6. Proposed design for high precision refractive index sensor using integrated planar lightwave circuit

    NASA Astrophysics Data System (ADS)

    Maru, Koichi; Fujii, Yusaku; Zhang, Shulian; Hou, Wenmei

    2009-07-01

    A high precision and compact refractive index sensor is proposed. The combination of coarse measurement utilizing the change of the angle of refraction and fine measurement utilizing the phase change is newly proposed to measure absolute refractive index precisely. The proposed method does not need expensive optical measurement equipment such as an optical spectrum analyzer. The integrated planar lightwave circuit (PLC) technology enables us to obtain a compact sensor that is preferable for the practical use. The principle, design, and some configurations for precise refractive index measurement are described.

  7. Research on high precision equal-angle scanning method in rotary kiln temperature measurement system

    NASA Astrophysics Data System (ADS)

    Dai, Shaosheng; Guo, Zhongyuan; You, Changhui; Liu, Jinsong; Cheng, Yang; Tang, Huaming

    2016-05-01

    Aiming at traditional horizontal equal-angle scanning method's disadvantage of measurement error, a high precision equal-angle scanning method is proposed, the proposed method establishes a tilt scanning model by the following steps: introducing height variable, precisely calculating the viewing angle, building scanning model. The model is used to calculate scanning position on rotary kiln's surface, which helps to locate and track temperature variation. The experiment shows that the proposed method can effectively improve the precision of temperature spots' location on the rotary kiln surface.

  8. Development of a practical method of estimating electric power from various photovoltaic technologies with high precision

    NASA Astrophysics Data System (ADS)

    Ishii, Tetsuyuki; Sato, Ritsuko; Choi, Sungwoo; Chiba, Yasuo; Masuda, Atsushi

    2017-08-01

    The purpose of this study is to develop a method of estimating the electric power from various photovoltaic technologies with high precision. The actual outdoor performance of eight kinds (12 types) of photovoltaic (PV) modules has been measured since January 2012 in order to verify the precision of the method. Using ambient climatic datasets including solar irradiance, module temperature, and solar spectrum, the performance of these PV modules is corrected to the performance under standard test conditions (STC), which should be constant ideally. The results indicate that the performance of bulk crystalline silicon (c-Si) and copper indium gallium diselenide (CIGS) PV modules can be estimated with high precision (approximately less than ±2%). However, the estimation precision of thin-film Si and cadmium telluride (CdTe) PV modules is low because of the initial light-induced degradation and seasonal variation due to metastability.

  9. A High-Precision, Optical Polarimeter to Measure Inclinations of High Mass X-Ray Binaries

    NASA Astrophysics Data System (ADS)

    Wiktorowicz, Sloane; Matthews, K.; Kulkarni, S. R.

    2007-12-01

    While most astrophysical objects require many parameters in order to be fully described, black holes are unique in that only three parameters are required: mass, spin, and charge. Of these, mass and spin are enough to describe the black hole's gravitational field and event horizon location. Therefore, theory and observation may jointly pursue one or two quantities to uncover the progenitor star's history. Constraints on black hole mass exist for high mass X-ray binaries, such as Cygnus X-1, which is thought to consist of a 40 ± 10 solar mass O9.7Iab star and a 13.5-29 solar mass black hole (Ziolkowski 2005). While the constraints on the mass of the compact object are tight enough to declare that it is a black hole, they are sufficiently loose as to prohibit precise modeling of the progenitor star's mass. We have built an optical polarimeter for the Hale 5-m telescope at Mt. Palomar to provide an independent method for determining black hole mass. Degree of polarization will vary for an edge-on system, while position angle of net polarization will vary for a face-on system. Therefore, by monitoring the linear polarimetric variability of the binary, inclination can be estimated. Coupled with the known mass function of the binary from radial velocity work (Gies et al. 2003), inclination estimates constrain the mass of the black hole. Our polarimeter, POLISH (POLarimeter for Inclination Studies of High mass x-ray binaries), has achieved linear polarimetric precision of less than 10 parts per million on bright, unpolarized standard stars. We will also present results for polarized standard stars and Cygnus X-1 itself. This instrument has been funded by an endowment from the Moore Foundation.

  10. Chromium - blood test

    MedlinePlus

    ... work in the following industries: Leather tanning Electroplating Steel manufacturing Decreased chromium level only occurs in people who receive all of their nutrition by vein (total parenteral nutrition or TPN) and do not get enough chromium.

  11. Chromium in diet

    MedlinePlus

    Chromium deficiency may be seen as impaired glucose tolerance. It occurs in older people with type 2 diabetes and in infants with protein-calorie malnutrition. Taking chromium supplements can help manage these conditions. However, ...

  12. FOTOMCAp: a new quasi-automatic code for high-precision photometry

    NASA Astrophysics Data System (ADS)

    Petrucci, R.; Jofré, J. E.

    2016-08-01

    The search for Earth-like planets using the transit technique has encouraged the development of strategies to obtain light curves with increasing precision. In this context we developed the fotomcap program. This is an iraf quasi-automatic code which employs the aperture correction method and allows to obtain high-precision light curves. In this contribution we describe how this code works and show the results obtained for planetary transits light curves.

  13. Construction of a versatile high precision ambient ionization source for direct analysis and imaging.

    PubMed

    Sampson, Jason S; Hawkridge, Adam M; Muddiman, David C

    2008-10-01

    The design and construction of a high precision ambient ionization source matrix-assisted laser desorption electrospray ionization (MALDESI) are described in full detail, including a complete parts list. The computer controlled high precision motion control system and high repetition rate Explorer laser are demonstrated during MALDESI-FT-ICR analysis of peptides and proteins ranging from 1 to 17 kDa. The high stability ionization source platform described herein demonstrates both the advantages of the new MALDESI source and versatility for application to numerous desorption and ionization techniques.

  14. Use of Terrestrial Laser Scanning Technology for Long Term High Precision Deformation Monitoring

    PubMed Central

    Vezočnik, Rok; Ambrožič, Tomaž; Sterle, Oskar; Bilban, Gregor; Pfeifer, Norbert; Stopar, Bojan

    2009-01-01

    The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable. PMID:22303152

  15. Machine vision for high-precision volume measurement applied to levitated containerless material processing

    SciTech Connect

    Bradshaw, R.C.; Schmidt, D.P.; Rogers, J.R.; Kelton, K.F.; Hyers, R.W.

    2005-12-15

    By combining the best practices in optical dilatometry with numerical methods, a high-speed and high-precision technique has been developed to measure the volume of levitated, containerlessly processed samples with subpixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermophysical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the subpixel locations of sample edges and, in turn, produce high-precision measurements.

  16. [Bioremediation of chromium (VI) contaminated site by reduction and microbial stabilization of chromium].

    PubMed

    Zheng, Jia-Chuan; Zhang, Jian-Rong; Liu, Xi-Wen; Xu, Qian; Shi, Wei-Lin

    2014-10-01

    Chromium (VI) contaminated soil samples were collected from a chemical plant in Suzhou. Firstly, the reduced soil was prepared by adding reagent (Stone-sulfure reagent) into polluted soil to transfer most chromium (VI) into chromium (III), then a nutrient solution was introduced into the reduced soil, and the stabilized soil was obtained after 60 days culturing. The chromium (VI) content of the three kinds of soil was analyzed. The results showed that the chromium (VI) content in toxicity characteristic leaching liquid (TCLL) dropped by 96. 8% (from 8.26 mg · L(-1) to 0.26 mg · L(-1)), and the total chromium content dropped by 95.7% (from 14.66 mg · L(-1) to 0.63 mg · L(-1)) after bioremediation in 5% nutrient solution. Additionally, the durability of chromium stabilization was tested by potassium permanganate oxidation and sterilization of microbe-treated soil. After oxidation, the chromium (VI) content in TCLL of the reduced soil was increased from 8.26 mg · L(-1) to 14.68 mg · L(-1). However, the content after bioremediation was decreased to 2.68 mg · L(-1). The results of sterilization demonstrated that the death of microbe had no significant effect on the stabilization of chromium. Consequently, the research in this paper demonstrated the feasibility of bioremediation of chromium (VI) polluted soil through reduction followed by stabilization/soilidification, and provided a technique with low cost but high efficiency.

  17. Design and algorithm research of high precision airborne infrared touch screen

    NASA Astrophysics Data System (ADS)

    Zhang, Xiao-Bing; Wang, Shuang-Jie; Fu, Yan; Chen, Zhao-Quan

    2016-10-01

    There are shortcomings of low precision, touch shaking, and sharp decrease of touch precision when emitting and receiving tubes are failure in the infrared touch screen. A high precision positioning algorithm based on extended axis is proposed to solve these problems. First, the unimpeded state of the beam between emitting and receiving tubes is recorded as 0, while the impeded state is recorded as 1. Then, the method of oblique scan is used, in which the light of one emitting tube is used for five receiving tubes. The impeded information of all emitting and receiving tubes is collected as matrix. Finally, according to the method of arithmetic average, the position of the touch object is calculated. The extended axis positioning algorithm is characteristic of high precision in case of failure of individual infrared tube and affects slightly the precision. The experimental result shows that the 90% display area of the touch error is less than 0.25D, where D is the distance between adjacent emitting tubes. The conclusion is gained that the algorithm based on extended axis has advantages of high precision, little impact when individual infrared tube is failure, and using easily.

  18. Adverse Reactions to Metal on Polyethylene Implants: Highly destructive lesions related to elevated concentration of Cobalt and Chromium in synovial fluid.

    PubMed

    Eltit, Felipe; Assiri, Ali; Garbuz, Donald; Duncan, Clive; Masri, Bassam; Greidanus, Nelson; Bell, Robert; Sharma, Manju; Cox, Michael; Wang, Rizhi

    2017-03-07

    Adverse local tissue reactions (ALTR) are the primary cause of failure of metal on metal (MoM) hip implants, and fewer but not negligible number cases of non-modular metal on polyethylene (MoP) implants. In this study we analyzed 17 cases of MoP ALTR, and equal number of MoM, by histological observation, cobalt and chromium concentration in serum and synovial fluid and cytokine analysis in ALTR tissues. ALTRs in MoP are highly necrotic, affecting larger areas than MoM ALTRs. Degenerative changes in blood vessels' wall were seen in all MoP ALTRs. The concentration of cobalt and chromium was higher in synovial fluid but lower in serum of MoP patients compared to MoM patients. Elevated concentrations of chemokines were observed in ALTR tissues. We conclude that ALTRs in MoP systems are highly necrotizing lesions that seem to have a similar development to ALTRs in MoM. Alteration of vessels wall seems to have a role in the tissues necrosis, as well as the elevated concentration of cobalt and chromium in synovial fluid of MoP patients. Chemokines may be involved in the pathogenesis of ALTR and constitute possible diagnostic targets. This article is protected by copyright. All rights reserved.

  19. Thoria stability in TD-NiCr at high temperatures in the presence of chromium in solution.

    NASA Technical Reports Server (NTRS)

    Dalal, H.; Grant, N. J.

    1973-01-01

    Study of the influence of chromium in solid solution on the coarsening of ThO2 in TD-NiCr. Comparisons were made of ThO2 coarsening in chromium-free TD-Ni and in TD-NiCr, which is known to be low in Cr2O3 as a contaminant. The results of these comparisons indicate that the presence of 20% Cr in solid solution in a nickel-base alloy does not lead to a more rapid coarsening of ThO2 at temperatures of at least 2462 deg F (1350 deg C).

  20. Thoria stability in TD-NiCr at high temperatures in the presence of chromium in solution.

    NASA Technical Reports Server (NTRS)

    Dalal, H.; Grant, N. J.

    1973-01-01

    Study of the influence of chromium in solid solution on the coarsening of ThO2 in TD-NiCr. Comparisons were made of ThO2 coarsening in chromium-free TD-Ni and in TD-NiCr, which is known to be low in Cr2O3 as a contaminant. The results of these comparisons indicate that the presence of 20% Cr in solid solution in a nickel-base alloy does not lead to a more rapid coarsening of ThO2 at temperatures of at least 2462 deg F (1350 deg C).

  1. Error analysis of high-rate GNSS precise point positioning for seismic wave measurement

    NASA Astrophysics Data System (ADS)

    Shu, Yuanming; Shi, Yun; Xu, Peiliang; Niu, Xiaoji; Liu, Jingnan

    2017-06-01

    High-rate GNSS precise point positioning (PPP) has been playing a more and more important role in providing precise positioning information in fast time-varying environments. Although kinematic PPP is commonly known to have a precision of a few centimeters, the precision of high-rate PPP within a short period of time has been reported recently with experiments to reach a few millimeters in the horizontal components and sub-centimeters in the vertical component to measure seismic motion, which is several times better than the conventional kinematic PPP practice. To fully understand the mechanism of mystified excellent performance of high-rate PPP within a short period of time, we have carried out a theoretical error analysis of PPP and conducted the corresponding simulations within a short period of time. The theoretical analysis has clearly indicated that the high-rate PPP errors consist of two types: the residual systematic errors at the starting epoch, which affect high-rate PPP through the change of satellite geometry, and the time-varying systematic errors between the starting epoch and the current epoch. Both the theoretical error analysis and simulated results are fully consistent with and thus have unambiguously confirmed the reported high precision of high-rate PPP, which has been further affirmed here by the real data experiments, indicating that high-rate PPP can indeed achieve the millimeter level of precision in the horizontal components and the sub-centimeter level of precision in the vertical component to measure motion within a short period of time. The simulation results have clearly shown that the random noise of carrier phases and higher order ionospheric errors are two major factors to affect the precision of high-rate PPP within a short period of time. The experiments with real data have also indicated that the precision of PPP solutions can degrade to the cm level in both the horizontal and vertical components, if the geometry of satellites is

  2. Molecular calipers for highly precise and accurate measurements of single-protein mechanics.

    PubMed

    Wang, Yanyan; Hu, Xiaodong; Bu, Tianjia; Hu, Chunguang; Hu, Xiaotang; Li, Hongbin

    2014-03-18

    Single-molecule atomic force spectroscopy (AFM) has evolved into a powerful technique toward elucidating conformational changes in proteins when exposed to applied force. AFM technologies that are currently available allow for precise measurements of proteins length changes during conformational transitions. However, because of systematic errors in piezo calibration as well as errors originating from fitting experimental data using a worm-like chain model of polymer elasticity, high-precision measurements of length changes do not necessarily translate into highly accurate measurements of length changes, resulting in uncertainty in obtaining structural information about protein conformational changes. Actually achieving highly precise and accurate force spectroscopy measurements remains a challenge. Here, we report a protein caliper method that eliminates systematic errors that occur during single-protein force spectroscopy measurements, and thus achieves highly precise and accurate length change measurements in protein mechanics studies. To do this, a series of loop elongation variants of the small protein GB1, which differ by 2, 5, 10, 15, and 24 amino acid residues, were engineered. Differential measurements of amino acid residue length obtained from different AFM setups result in a precise measure of the length of a single amino acid residue, which varies within different AFM setups because of systematic error between individual AFM piezoelectric calibrations. The measured length of a single amino acid residue from a given AFM setup is then used as a caliper for the given setup to eliminate systematic error, leading to highly accurate and precise measurements of the number of amino acid residues that are involved in a conformation change of a polypeptide chain. We further developed a more precise, robust, and model-free method to determine the apparent size of single amino acid residues and conformational changes of proteins. This method improves the accuracy of

  3. Research on high-precision laser displacement sensor-based error compensation model

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifeng; Zhai, Yusheng; Su, Zhan; Qiao, Lin; Tang, Yiming; Wang, Xinjie; Su, Yuling; Song, Zhijun

    2015-08-01

    The triangulation measurement is a kind of active vision measurement. The laser triangulation displacement is widely used with advantages of non-contact, high precision, high sensitivity. The measuring error will increase with the nonlinear and noise disturbance when sensors work in large distance. The paper introduces the principle of laser triangulation measurement and analyzes the measuring error and establishes the compensation error. Spot centroid is extracted with digital image processing technology to increase noise-signal ratio. Results of simulation and experiment show the method can meet requirement of large distance and high precision.

  4. Flower-like self-assembly of gold nanoparticles for highly sensitive electrochemical detection of chromium(VI)

    PubMed Central

    Ouyang, Ruizhuo; Bragg, Stefanie A.; Chambers, James Q.; Xue, Zi-Ling

    2012-01-01

    We report here the fabrication of a flower-like self-assembly of gold nanoparticles (AuNPs) on a glassy carbon electrode (GCE) as a highly sensitive platform for ultratrace Cr(VI) detection. Two AuNPs layers are used in the current approach, in which the first is electroplated on the GCE surface as anchors for binding to an overcoated thiol sol-gel film derived from 3-mercaptopropyltrimethoxysilane (MPTS). The second AuNPs layer is then self-assembled on the surface of the sol-gel film, forming flower-like gold nanoelectrodes enlarging the electrode surface. When functionalized by a thiol pyridinium, the fabricated electrode displays a well-defined peak for selective Cr(VI) reduction with an unusually large, linear concentration range of 10–1,200 ng L−1 and a low detection limit of 2.9 ng L−1. In comparison to previous approaches using MPTS and AuNPs on Au electrodes, the current work expands the use of AuNPs to the GCE. Subsequent functionalization of the secondary AuNPs by a thiol pyridinium and adsorption/preconcentration of Cr(VI) lead to the unusually large detection range and high sensitivity. The stepwise preparation of the electrode has been characterized by electrochemical impedance spectroscopy (EIS), scanning electronic microscopy (SEM), and IR. The newly designed electrode exhibits good stability, and has been successfully employed to measure chromium in a pre-treated blood sample. The method demonstrates acceptable fabrication reproducibility and accuracy. PMID:22444528

  5. Methods for high precision 14C AMS measurement of atmospheric CO2 at LLNL

    SciTech Connect

    Graven, H D; Guilderson, T P; Keeling, R F

    2006-10-18

    Development of {sup 14}C analysis with precision better than 2{per_thousand} has the potential to expand the utility of {sup 14}CO{sub 2} measurements for carbon cycle investigations as atmospheric gradients currently approach traditional measurement precision of 2-5{per_thousand}. The AMS facility at the Center for Accelerator Mass Spectrometry, Lawrence Livermore National Laboratory, produces high and stable beam currents that enable efficient acquisition times for large numbers of {sup 14}C counts. One million {sup 14}C atoms can be detected in approximately 25 minutes, suggesting that near 1{per_thousand} counting precision is economically feasible at LLNL. The overall uncertainty in measured values is ultimately determined by the variation between measured ratios in several sputtering periods of the same sample and by the reproducibility of replicate samples. Experiments on the collection of one million counts on replicate samples of CO{sub 2} extracted from a whole air cylinder show a standard deviation of 1.7{per_thousand} in 36 samples measured over several wheels. This precision may be limited by the reproducibility of Oxalic Acid I standard samples, which is considerably poorer. We outline the procedures for high-precision sample handling and analysis that have enabled reproducibility in the cylinder extraction samples at the <2{per_thousand} level and describe future directions to continue increasing measurement precision at LLNL.

  6. Flexible, non-contact and high-precision measurements of optical components

    NASA Astrophysics Data System (ADS)

    Beutler, A.

    2016-06-01

    A high-accuracy cylindrical coordinate measuring instrument developed for the measurement of optical components is presented. It is equipped with an optical point sensor system including a high aperture probe. This setup allows measurements to be performed with high accuracy in a flexible way. Applications include the measurement of the topography of high-precision aspheric and freeform lenses and diffractive structures. High measuring speeds guarantee the implementation in a closed-loop production process.

  7. Elemental speciation for chromium in chromium picolinate products

    NASA Astrophysics Data System (ADS)

    Ding, Hong; Olson, Lisa K.; Caruso, Joseph A.

    1996-12-01

    Chromium picolinate products have been examined for different forms of chromium, using chromatographic separation and inductively coupled plasma mass spectrometric detection. The brands we evaluated contained no detectable amount of elemental chromium(VI), the toxic form. Since chromium picolinate might have other chromium forms as impurities, different products may contain different forms of chromium species. Compared with ion-exchange, reversed-phase chromatography showed excellent chromium recovery based on the amount stated on the product label.

  8. Frictional and structural characterization of ion-nitrided low and high chromium steels

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1985-01-01

    Low Cr steels AISI 41410, AISI 4340, and high Cr austenitic stainless steels AISI 304, AISI 316 were ion nitrided in a dc glow discharge plasma consisting of a 75 percent H2 - 25 percent N2 mixture. Surface compound layer phases were identified, and compound layer microhardness and diffusion zone microhardness profiles were established. Distinct differences in surface compound layer hardness and diffusion zone profiles were determined between the low and high Cr alloy steels. The high Cr stainless steels after ion nitriding displayed a hard compound layer and an abrupt diffusion zone. The compound layers of the high Cr stainless steels had a columnar structure which accounts for brittleness when layers are exposed to contact stresses. The ion nitrided surfaces of high and low Cr steels displayed a low coefficient of friction with respect to the untreated surfaces when examined in a pin and disk tribotester.

  9. Frictional and structural characterization of ion-nitrided low and high chromium steels

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1985-01-01

    Low Cr steels AISI 41410, AISI 4340, and high Cr austenitic stainless steels AISI 304, AISI 316 were ion nitrided in a dc glow discharge plasma consisting of a 75 percent H2 - 25 percent N2 mixture. Surface compound layer phases were identified, and compound layer microhardness and diffusion zone microhardness profiles were established. Distinct differences in surface compound layer hardness and diffusion zone profiles were determined between the low and high Cr alloy steels. The high Cr stainless steels after ion nitriding displayed a hard compound layer and an abrupt diffusion zone. The compound layers of the high Cr stainless steels had a columnar structure which accounts for brittleness when layers are exposed to contact stresses. The ion nitrided surfaces of high and low Cr steels displayed a low coefficient of friction with respect to the untreated surfaces when examined in a pin and disk tribotester.

  10. High Throughput, High Precision Hot Testing Tool for HBLED Wafer Level Testing

    SciTech Connect

    Solarz, Richard; McCord, Mark

    2015-12-31

    The Socrates research effort developed an in depth understanding and demonstrated in a prototype tool new precise methods for teh characterization of color characteristics and flux from individual LEDs for the production of uniform quality lighting. This effort was focused on improving the color quality and consistency of solid state lighting and potentially reducing characterization costs for all LED product types. The patented laser hot testing method was demonstrated to be far more accurate than all current state of the art color and flux characterization methods in use by the solid state lighting industry today. A seperately patented LED grouping method (statistical binning) was demonstrated to be a useful approach to improving utilization of entire lots of large color and flux distributions of manufactured LEDs for high quality color solid-state lighting. At the conclusion of the research in late 2015 the solid-state lighting industry was however generally satisfied with its existing production methods for high quality color products for the small segment of customers that demand it, albeit with added costs.

  11. High precision locating control system based on VCM for Talbot lithography

    NASA Astrophysics Data System (ADS)

    Yao, Jingwei; Zhao, Lixin; Deng, Qian; Hu, Song

    2016-10-01

    Aiming at the high precision and efficiency requirements of Z-direction locating in Talbot lithography, a control system based on Voice Coil Motor (VCM) was designed. In this paper, we built a math model of VCM and its moving characteristic was analyzed. A double-closed loop control strategy including position loop and current loop were accomplished. The current loop was implemented by driver, in order to achieve the rapid follow of the system current. The position loop was completed by the digital signal processor (DSP) and the position feedback was achieved by high precision linear scales. Feed forward control and position feedback Proportion Integration Differentiation (PID) control were applied in order to compensate for dynamic lag and improve the response speed of the system. And the high precision and efficiency of the system were verified by simulation and experiments. The results demonstrated that the performance of Z-direction gantry was obviously improved, having high precision, quick responses, strong real-time and easily to expend for higher precision.

  12. Chromium regulation of multiple gene expression in rats with high-fructose diet-induced metabolic syndrome

    USDA-ARS?s Scientific Manuscript database

    Chromium (Cr) supplementation alleviates the metabolic syndrome, glucose intolerance, depression, excess body fat, and type 2 diabetes. However, not all studies have reported beneficial effects of Cr. Molecular evidence is lacking on the effects of Cr. The objective of this study was to investigate ...

  13. Detection of highly toxic elements (lead and chromium) in commercially available eyeliner (kohl) using laser induced break down spectroscopy

    NASA Astrophysics Data System (ADS)

    Gondal, M. A.; Dastageer, M. A.; Al-Adel, F. F.; Naqvi, A. A.; Habibullah, Y. B.

    2015-12-01

    A sensitive laser induced breakdown spectroscopic system was developed and optimized for using it as a sensor for the detection of trace levels of lead and chromium present in the cosmetic eyeliner (kohl) of different price ranges (brands) available in the local market. Kohl is widely used in developing countries for babies as well adults for beautification as well eyes protection. The atomic transition lines at 405.7 nm and 425.4 nm were used as the marker lines for the detection of lead and chromium respectively. The detection system was optimized by finding the appropriate gate delay between the laser excitation and the data acquisition system and also by achieving optically thin plasma near the target by establishing the local thermodynamic equilibrium condition. The detection system was calibrated for these two hazardous elements and the kohl samples under investigation showed 8-15 ppm by mass of lead and 4-9 ppm by mass of Chromium, which are higher than the safe permissible levels of these elements. The limits of detection of the LIBS system for lead and chromium were found to be 1 and 2 ppm respectively.

  14. Computer Simulation and Experimental Validation on the Oxidation and Sulfate Corrosion Resistance of Novel Chromium Based High Temperature Alloys

    SciTech Connect

    Yang, Shizhong

    2013-02-28

    This report summarizes our recent works of ab initio molecular dynamics inter-atomic potentials development on dilute rare earth element yttrium (Y) etc. doped chromium (Cr) alloy systems, its applications in oxidation and corrosion resistance simulation, and experiment validation on the candidate systems. The simulation methods, experimental validation techniques, achievements already reached, students training, and future improvement are briefly introduced.

  15. Dynamic evaluation system for interpolation errors in the encoder of high precision

    NASA Astrophysics Data System (ADS)

    Wan, Qiu-hua; Wu, Yong-zhi; Zhao, Chang-hai; Liang, Li-hui; Sun, Ying; Jiang, Yong

    2009-05-01

    In order to measure dynamic interpolation errors of photoelectric encoder of high precision, the dynamic evaluation system of interpolation errors is introduced. Firstly, the fine Moiré signal of encoder which is collected with the high-speed data gathering card into the computer is treated to equiangular data with the method of linear interpolation. Then, the analysis of harmonic wave with the FFT is processed. Compared with the standard signal, the dynamic interpolation errors of the encoder are calculated. Experimental results show that the precision of the dynamic evaluation system of interpolation errors is +/-0.1 %( pitch). The evaluation system is simple, fast, high precision, and can be used in the working field of the encoder.

  16. Removal of chromium from wastewater by reverse osmosis

    NASA Astrophysics Data System (ADS)

    Çimen, Aysel

    2015-07-01

    Removal of chromium from wastewaters has been studied and the optimal process conditions were determined. The reverse osmosis (RO) technique, the sea water high rejection (SWHR) and high rejection brackish water (AG, SE, and SG) membranes were used. The chromium rejection depended on membrane type, pH of the feed water and operating pressure. The removal of chromium was most effective when the feed water pH 3. The rejection efficiency of the membranes increased in the order AG > SWHR > SG > SE. RO method can be efficiently used (with >91% rejection) for the removal of chromium from wastewater of chromium coating processes.

  17. Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

    NASA Technical Reports Server (NTRS)

    Peters, Christopher J.; Danehy, Paul M.; Bathel, Brett F.; Jiang, Naibo; Calvert, Nathan D.; Miles, Richard B.

    2015-01-01

    Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

  18. Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems

    NASA Technical Reports Server (NTRS)

    Peters, Christopher J.; Danehy, Paul M.; Bathel, Brett F.; Jiang, Naibo; Calvert, Nathan D.; Miles, Richard B.

    2015-01-01

    Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

  19. Challenges in mold manufacturing for high precision molded diffractive optical elements

    NASA Astrophysics Data System (ADS)

    Pongs, Guido; Bresseler, Bernd; Schweizer, Klaus; Bergs, Thomas

    2016-09-01

    Isothermal precision glass molding of imaging optics is the key technology for mass production of precise optical elements. Especially for numerous consumer applications (e.g. digital cameras, smart phones, …), high precision glass molding is applied for the manufacturing of aspherical lenses. The usage of diffractive optical elements (DOEs) can help to further reduce the number of lenses in the optical systems which will lead to a reduced weight of hand-held optical devices. But today the application of molded glass DOEs is limited due to the technological challenges in structuring the mold surfaces. Depending on the application submicrometer structures are required on the mold surface. Furthermore these structures have to be replicated very precisely to the glass lens surface. Especially the micro structuring of hard and brittle mold materials such as Tungsten Carbide is very difficult and not established. Thus a multitude of innovative approaches using diffractive optical elements cannot be realized. Aixtooling has investigated in different mold materials and different suitable machining technologies for the micro- and sub-micrometer structuring of mold surfaces. The focus of the work lays on ultra-precision grinding to generate the diffractive pattern on the mold surfaces. This paper presents the latest achievements in diffractive structuring of Tungsten Carbide mold surfaces by ultra-precision grinding.

  20. High precision semi-automated vertebral height measurement using computed tomography: A phantom study.

    PubMed

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Ward, Michael M

    2012-01-01

    The measurement of vertebral heights is necessary for the evaluation of many disorders affecting the spine. High precision is particularly important for longitudinal studies where subtle changes are to be detected. Computed tomography (CT) is the modality of choice for high precision studies. Radiography and dual emission X-ray absorptiometry (DXA) use 2D images to assess 3D structures, which can result in poor visualization due to the superimposition of extraneous anatomical objects on the same 2D space. We present a semi-automated computer algorithm to measure vertebral heights in the 3D space of a CT scan. The algorithm segments the vertebral bodies, extracts their end plates and computes vertebral heights as the mean distance between end plates. We evaluated the precision of our algorithm using repeat scans of an anthropomorphic vertebral phantom. Our method has high precision, with a coefficient of variation of only 0.197% and Bland-Altmann 95% limits of agreement of [-0.11, 0.13] mm. For local heights (anterior, middle, posterior) the algorithm was up to 4.2 times more precise than a manual mid-sagittal plane method.

  1. High precision measurement of the proton charge radius: The PRad experiment

    SciTech Connect

    Meziane, Mehdi

    2013-11-01

    The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 {+-} 0.0007 fm was extracted which is 7{sigma} smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these "electronic" determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved at Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup -4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.

  2. High precision measurement of the proton charge radius: The PRad experiment

    SciTech Connect

    Meziane, Mehdi; Collaboration: PRad Collaboration

    2013-11-07

    The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 ± 0.0007 fm was extracted which is 7σ smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these 'electronic' determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved at Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup −4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.

  3. CHEOPS: a space telescope for ultra-high precision photometry of exoplanet transits

    NASA Astrophysics Data System (ADS)

    Fortier, Andrea; Beck, Thomas; Benz, Willy; Broeg, Christopher; Cessa, Virginie; Ehrenreich, David; Thomas, Nicolas

    2014-08-01

    The CHaracterising ExOPlanet Satellite (CHEOPS) is a joint ESA-Switzerland space mission (expected to launch in 2017) dedicated to search for exoplanet transits by means of ultra-high precision photometry. CHEOPS will provide accurate radii for planets down to Earth size. Targets will mainly come from radial velocity surveys. The CHEOPS instrument is an optical space telescope of 30 cm clear aperture with a single focal plane CCD detector. The tube assembly is passively cooled and thermally controlled to support high precision, low noise photometry. The telescope feeds a re-imaging optic, which supports the straylight suppression concept to achieve the required Signal to Noise.

  4. Fabrication and Assembly of High-Precision Hinge and Latch Joints for Deployable Optical Instruments

    NASA Technical Reports Server (NTRS)

    Phelps, James E.

    1999-01-01

    Descriptions are presented of high-precision hinge and latch joints that have been co-developed, for application to deployable optical instruments, by NASA Langley Research Center and Nyma/ADF. Page-sized versions of engineering drawings are included in two appendices to describe all mechanical components of both joints. Procedures for assembling the mechanical components of both joints are also presented. The information herein is intended to facilitate the fabrication and assembly of the high-precision hinge and latch joints, and enable the incorporation of these joints into the design of deployable optical instrument systems.

  5. High precision NC lathe feeding system rigid-flexible coupling model reduction technology

    NASA Astrophysics Data System (ADS)

    Xuan, He; Hua, Qingsong; Cheng, Lianjun; Zhang, Hongxin; Zhao, Qinghai; Mao, Xinkai

    2017-08-01

    This paper proposes the use of dynamic substructure method of reduction of order to achieve effective reduction of feed system for high precision NC lathe feeding system rigid-flexible coupling model, namely the use of ADAMS to establish the rigid flexible coupling simulation model of high precision NC lathe, and then the vibration simulation of the period by using the FD 3D damper is very effective for feed system of bolt connection reduction of multi degree of freedom model. The vibration simulation calculation is more accurate, more quickly.

  6. A high precision attitude determination and control system for the UYS-1 nanosatellite

    NASA Astrophysics Data System (ADS)

    Chaurais, J. R.; Ferreira, H. C.; Ishihara, J. Y.; Borges, R. A.; Kulabukhov, A. M.; Larin, V. A.; Belikov, V. V.

    This paper presents the design of a high precision attitude determination and control system for the UYS-1 Ukrainian nanosatellite. Its main task is the 3-axis stabilization with less than 0.5° angle errors, so the satellite may take high precision photos of Earth's surface. To accomplish this task, this system comprises a star tracker and three reaction wheels. To avoid external disturbances and actuators faults, a PD-type and a PID-type robust controllers are simulated and the results are compared to an empirically adjusted PD controller.

  7. High-precision self-adaptive phase-calibration method for wavelength-tuning interferometry

    NASA Astrophysics Data System (ADS)

    Zhu, Xueliang; Zhao, Huiying; Dong, Longchao; Wang, Hongjun; Liu, Bingcai; Yuan, Daocheng; Tian, Ailing; Wang, Fangjie; Zhang, Chupeng; Ban, Xinxing

    2017-03-01

    We introduce a high-precision self-adaptive phase-calibration method for performing wavelength-tuning interferometry. Our method is insensitive to the nonlinearity of the phase shifter, even under random control. Intensity errors derived from laser voltage changes can be restrained by adopting this approach. Furthermore, this method can effectively overcome the influences from the background and modulation intensities in the interferogram, regardless of the phase structure. Numerical simulations and experiments are implemented to verify the validity of this high-precision calibration method.

  8. Towards high precision measurements of nuclear g-factors for the Be isotopes

    NASA Astrophysics Data System (ADS)

    Takamine, A.; Wada, M.; Okada, K.; Ito, Y.; Schury, P.; Arai, F.; Katayama, I.; Imamura, K.; Ichikawa, Y.; Ueno, H.; Wollnik, H.; Schuessler, H. A.

    2016-06-01

    We describe the present status of future high-precision measurements of nuclear g-factors utilizing laser-microwave double and laser-microwave-rf triple resonance methods for online-trapped, laser-cooled radioactive beryllium isotope ions. These methods have applicability to other suitably chosen isotopes and for beryllium show promise in deducing the hyperfine anomaly of 11Be with a sufficiently high precision to study the nuclear magnetization distribution of this one-neutron halo nucleus in a nuclear-model-independent manner.

  9. Chromium adsorption by lignin

    SciTech Connect

    Lalvani, S.B.; Huebner, A.; Wiltowski, T.S.

    2000-01-01

    Hexavalent chromium is a known carcinogen, and its maximum contamination level in drinking water is determined by the US Environmental Protection Agency (EPA). Chromium in the wastewaters from plating and metal finishing, tanning, and photographic industries poses environmental problems. A commercially available lignin was used for the removal of hexavalent as well as trivalent chromium from aqueous solution. It is known that hexavalent chromium is present as an anionic species in the solution. It was found that lignin can remove up to 63% hexavalent and 100% trivalent chromium from aqueous solutions. The removal of chromium ions was also investigated using a commercially available activated carbon. This absorbent facilitated very little hexavalent and almost complete trivalent chromium removal. Adsorption isotherms and kinetics data on the metal removal by lignin and activated carbon are presented and discussed.

  10. A high-precision calculation method for interface normal and curvature on an unstructured grid

    NASA Astrophysics Data System (ADS)

    Ito, Kei; Kunugi, Tomoaki; Ohno, Shuji; Kamide, Hideki; Ohshima, Hiroyuki

    2014-09-01

    In the volume-of-fluid algorithm, the calculations of the interface normal and curvature are crucially important for accurately simulating interfacial flows. However, few methods have been proposed for the high-precision interface calculation on an unstructured grid. In this paper, the authors develop a height function method that works appropriately on an unstructured grid. In the process, the definition of the height function is discussed, and the high-precision calculation method of the interface normal is developed to meet the necessary condition for a second-order method. This new method has highly reduced computational cost compared with a conventional high-precision method because the interface normal calculation is completed by solving relatively simple algebraic equations. The curvature calculation method is also discussed and the approximated quadric curve of an interface is employed to calculate the curvature. Following a basic verification, the developed height function method is shown to successfully provide superior calculation accuracy and highly reduced computational cost compared with conventional calculation methods in terms of the interface normal and curvature. In addition, the height function method succeeds in calculating accurately the slotted-disk revolution problem and the oscillating drop on unstructured grids. Therefore, the developed height function method is confirmed to be an efficient technique for the high-precision numerical simulation of interfacial flows on an unstructured grid.

  11. Palladium-chromium static strain gage for high temperature propulsion systems

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1991-01-01

    The present electrical strain gage for high temperature static strain measurements is in its fine-wire and thin-film forms designed to be temperature-compensated on any substrate material. The gage element is of Pd-Cr alloy, while the compensator is of Pt. Because the thermally-induced apparent strain of this compensated wire strain gage is sufficiently small, with good reproducibility between thermal cycles to 800 C, output figures can be corrected within a reasonable margin of error.

  12. Development of Low-Noise High Value Chromium Silicide Resistors for Cryogenic Detector Applications

    NASA Technical Reports Server (NTRS)

    Jhabvala, Murzy; Babu, Sachi; Monroy, Carlos; Darren, C.; Krebs, Carolyn A. (Technical Monitor)

    2001-01-01

    Extremely high sensitivity detectors, such as silicon bolometers are required in many NASA missions for detection of photons from the x-ray to the far infrared regions. Typically, these detectors are cooled to well below the liquid helium (LHe) temperature (4.2 K) to achieve the maximum detection performance. As photoconductors, they are generally operated with a load resistor and a pre-set bias voltage, which is then coupled to the input gate of a source-follower Field Effect Transistor (FET) circuit. It is imperative that the detector system signal to noise performance be limited by the noise of the detector and not by the noise of the external components. The load resistor value is selected to optimize the detector performance. These two criteria tend to be contradictory in that these detectors require load resistors in the hundreds of megaohms, which leads to a higher Johnson noise. Additionally, the physical size of the resistor must be small for device integration as required by such missions as the NASA High Resolution Airborne Wide-Band Camera (HAWC) instrument and the Submillimeter High Angular Resolution Camera (SHARC) for the Caltech Submillimeter Observatory (CSO). We have designed, fabricated and characterized thin film resistors using a CrSi/TiW/Al metal system on optical quality quartz substrates. The resistor values range from 100 megaohms to over 650 megaohms and are Johnson noise limited at LHe temperatures. The resistor film is sputtered with a sheet resistance ranging from 300 ohms to 1600 ohms and the processing sequence developed for these devices allows for chemically fine tuning the sheet resistance in-situ. The wafer fabrication process was of sufficiently high yield (>80%) providing clusters of good resistors for integrated multiple detector channels, a very important feature in the assembly of these two instruments.

  13. Palladium-chromium static strain gage for high temperature propulsion systems

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1991-01-01

    The present electrical strain gage for high temperature static strain measurements is in its fine-wire and thin-film forms designed to be temperature-compensated on any substrate material. The gage element is of Pd-Cr alloy, while the compensator is of Pt. Because the thermally-induced apparent strain of this compensated wire strain gage is sufficiently small, with good reproducibility between thermal cycles to 800 C, output figures can be corrected within a reasonable margin of error.

  14. High-precision absolute distance and vibration measurement with frequency scanned interferometry

    SciTech Connect

    Yang, H.-J.; Deibel, Jason; Nyberg, Sven; Riles, Keith

    2005-07-01

    We report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer was used to determine frequency changes during scanning. Two multiple-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, measurement precision of {approx}50 nm was achieved for absolute distances ranging from 0.1 to 0.7 m by use of the first multiple-distance-measurement technique. The second analysis technique has the capability to measure vibration frequencies ranging from 0.1 to 100 Hz with an amplitude as small as a few nanometers without a priori knowledge.

  15. High-precision absolute distance and vibration measurement with frequency scanned interferometry.

    PubMed

    Yang, Hai-Jun; Deibel, Jason; Nyberg, Sven; Riles, Keith

    2005-07-01

    We report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer was used to determine frequency changes during scanning. Two multiple-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, measurement precision of approximately 50 nm was achieved for absolute distances ranging from 0.1 to 0.7 m by use of the first multiple-distance-measurement technique. The second analysis technique has the capability to measure vibration frequencies ranging from 0.1 to 100 Hz with an amplitude as small as a few nanometers without a priori knowledge.

  16. A high-precision K-band LFMCW radar for range measurement

    NASA Astrophysics Data System (ADS)

    Jia, Yingzhuo; Chen, Xiuwei; Zou, Yongliao

    2016-11-01

    K-band LFMCW radar may be applied in high-precision range measurement, if its range resolution is made be close to mm magnitude, good performance is not only needed in hardware design, algorithm selection and optimization is but also needed. In K-band LFMCW radar system, CZT algorithm is modified according to practical radar echo signal, its simulation model is built in the System Generator tool software, the corresponding algorithm is implemented in FPGA. K-band LFMCW radar may be applied in range measurement of great volume storage tank, the outfield experiment was done according to application, experiment result shows that range measurement precision may reach mm magnitude, the system can meet the requirement of remote high-precision measurement.

  17. High precision metrology method for unobscured Three Mirror Anastigmatic (TMA) mapping camera boresight

    NASA Astrophysics Data System (ADS)

    Zhao, Xi-ting; Jiao, Wen-chun; Liao, Zhi-bo

    2012-10-01

    High precision of mapping camera boresight directly affects the positioning accuracy of geographical location and photogrammetry. Although it can fulfill the request of good performance for unobscured TMA optical system, which adopted computer aided alignment method, single lens was unobscured which unable ascertain boresight by using lens centering technology, and boresight is randomicity as a result of compensating relation of multivariables. A novel method using the measurement of theodolite space intersection was proposed to rapidly and high accurately complete establish the relation between boresight and a cube in precision alignment stage, simultaneously, the relation of component deflexion and boresight have been simulated by computer model reverse optimization. Thus, the image quality and precision of boresight was effective operated according to the request of satellite assembly.

  18. High-precision tracking with non-blinking quantum dots resolves nanoscale vertical displacement.

    PubMed

    Marchuk, Kyle; Guo, Yijun; Sun, Wei; Vela, Javier; Fang, Ning

    2012-04-11

    Novel non-blinking quantum dots (NBQDs) were utilized in three-dimensional super-localization, high-precision tracking applications under an automated scanning-angle total internal reflection fluorescence microscope (SA-TIRFM). NBQDs were randomly attached to stationary microtubules along the radial axis under gliding assay conditions. By automatically scanning through a wide range of incident angles with different evanescent-field layer thicknesses, the fluorescence intensity decay curves were obtained. Fit with theoretical decay functions, the absolute vertical positions were determined with sub-10-nm localization precision. The emission intensity profile of the NBQDs attached to kinesin-propelled microtubules was used to resolve the self-rotation of gliding microtubules within a small vertical distance of ~50 nm. We demonstrate the applicability of NBQDs in high-precision fluorescence imaging experiments. © 2012 American Chemical Society

  19. High-Precision Floating-Point Arithmetic in ScientificComputation

    SciTech Connect

    Bailey, David H.

    2004-12-31

    At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required: some of these applications require roughly twice this level; others require four times; while still others require hundreds or more digits to obtain numerically meaningful results. Such calculations have been facilitated by new high-precision software packages that include high-level language translation modules to minimize the conversion effort. These activities have yielded a number of interesting new scientific results in fields as diverse as quantum theory, climate modeling and experimental mathematics, a few of which are described in this article. Such developments suggest that in the future, the numeric precision used for a scientific computation may be as important to the program design as are the algorithms and data structures.

  20. High-precision rotation angle measurement method based on monocular vision.

    PubMed

    Jin, Jing; Zhao, Lingna; Xu, Shengli

    2014-07-01

    To accurately measure the attitude angles (pitch, roll, and yaw) of a rigid object that rotates in a space, we propose a high-precision rotation angle measurement method based on monocular vision. This method combines camera self-calibration, multiview geometry, and 3D measurement. This monocular vision measuring system consists of an area scan CCD, a prime lens, and a spots array target, which are fixed on the measured object. We can calculate the rotation angle according to the rebuilt rotating spots array target by using this monocular vision measuring system. The measurement precision of rotation angle can reach 1 arc sec in this paper's experiments. This method has high measurement precision and good stability. Therefore we can widely use this method in machinery manufacturing, engineering measurement, aerospace, and the military.

  1. The Electrodeposition of Low Contraction Chromium Using High/Low Current Pulsing

    DTIC Science & Technology

    1993-03-01

    5200.22-M, Industrial Security Manual, Section 11-19 or DoD 5200.1- R , Information Security Program Regulation, Chapter IX. For unclassified, limited...Reducto-N PrOlec • 10704-ON). Weasinanon, OC 20503 1. AGENCY USE ONLY (Leave bldnk) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED March 1993 Final 4...C- 󈧅/30 A’M2 20 (c) ’S 40 ;0 20 30 •4 0 6P -C? 1 ME r ’ Figure 3. The effects of high/low current pulse plating on the (a) CCE, (b) hardness, and (c

  2. Figures deduction method for mast valuating interpolation errors of encoder with high precision

    NASA Astrophysics Data System (ADS)

    Yi, Jie; An, Li-min; Liu, Chun-xia

    2011-08-01

    With the development of technology, especially the need of fast accurately running after and orientating the aim of horizon and air, the photoelectrical rotary encoder with high precision has become the research hotspot in the fields of international spaceflight and avigation, the errors evaluation of encoder with high precision is the one of the key technology that must to be resolved. For the encoder with high precision, the interpolation errors is the main factor which affects its precision. Existing interpolation errors detection adopts accurate apparatus such as little angle measurement apparatus and optics polyhedron, requesting under the strict laboratory condition to carry on. The detection method is also time-consuming, hard to tackle and easy to introduce detect errors. This paper mainly studies the fast evaluation method of interpolation errors of encoder with high precision which is applied to the working field. Taking the Lissajou's figure produced by moiré fringe as foundation, the paper sets up the radius vector's mathematical model to represent figure's form deviation, analyses the implied parameters information of moiré fringe, the relation of the radius vector deviation and interpolation errors in the figures and puts forward the method of interpolation errors figures evaluation. Adopting figure deduction method, and directly from harmonic component of radius vector deviation toward harmonic component of interpolation errors, the interpolation errors can be gotten in the paper. Through data collecting card, the Moiré fringe signal is transmitted into the computer, then, the computer storages the data, using figures evaluation method to analyses the data, drawing the curve of interpolation errors. Comparing with interpolation errors drawing from traditional detect method, the change trend of the interpolation errors curve is similar, peak-peak value is almost equality. The result of experiment indicates: the method of the paper can be applied to

  3. Peculiarities of high-overtone transition probabilities in carbon monoxide revealed by high-precision calculation

    SciTech Connect

    Medvedev, Emile S.; Meshkov, Vladimir V.; Stolyarov, Andrey V.

    2015-10-21

    In the recent work devoted to the calculation of the rovibrational line list of the CO molecule [G. Li et al., Astrophys. J., Suppl. Ser. 216, 15 (2015)], rigorous validation of the calculated parameters including intensities was carried out. In particular, the Normal Intensity Distribution Law (NIDL) [E. S. Medvedev, J. Chem. Phys. 137, 174307 (2012)] was employed for the validation purposes, and it was found that, in the original CO line list calculated for large changes of the vibrational quantum number up to Δn = 41, intensities with Δn > 11 were unphysical. Therefore, very high overtone transitions were removed from the published list in Li et al. Here, we show how this type of validation is carried out and prove that the quadruple precision is indispensably required to predict the reliable intensities using the conventional 32-bit computers. Based on these calculations, the NIDL is shown to hold up for the 0 → n transitions till the dissociation limit around n = 83, covering 45 orders of magnitude in the intensity. The low-intensity 0 → n transition predicted in the work of Medvedev [Determination of a new molecular constant for diatomic systems. Normal intensity distribution law for overtone spectra of diatomic and polyatomic molecules and anomalies in overtone absorption spectra of diatomic molecules, Institute of Chemical Physics, Russian Academy of Sciences, Chernogolovka, 1984] at n = 5 is confirmed, and two additional “abnormal” intensities are found at n = 14 and 23. Criteria for the appearance of such “anomalies” are formulated. The results could be useful to revise the high-overtone molecular transition probabilities provided in spectroscopic databases.

  4. Phase transformation and long-term service of high-temperature martensitic chromium steels

    NASA Astrophysics Data System (ADS)

    Kalashnikov, I. S.; Tarasenko, L.; Acselrad, O.; Pereira, L. C.; Shalkevich, A.; Soboleva, G.

    2000-02-01

    Martensitic high Cr (10 - 16%) steels alloyed with Ni (Co), Mo, W, V, and N are widely used in constructions subjected to cyclic loads at temperatures up to 600 degrees Celsius, in general after quenching from 1100 - 1150 degrees Celsius followed by tempering at 650 - 690 degrees Celsius. Due to long term service exposure at high temperatures, different microstructural changes take place, such as second-phases precipitation, formation of low-angle grain boundaries, as well as internal damage caused by cyclic loads and creep. Specific phase diagrams are presented that can be used to define time periods for reliable operation of parts with given composition, based on the time required for the appearance of second phase particles known to be detrimental to mechanical strength and performance. Restoring thermal treatments to be applied after long time exposure at service conditions, aiming at increasing service life, are also presented and discussed. The combined use of the diagrams and the restoring treatment ensures prediction of a reliable service-life period for components made of these steels.

  5. Phase transformation and long-term service of high-temperature martensitic chromium steels

    NASA Astrophysics Data System (ADS)

    Kalashnikov, I. S.; Tarasenko, L.; Acselrad, O.; Pereira, L. C.; Shalkevich, A.; Soboleva, G.

    2001-02-01

    Martensitic high Cr (10 - 16%) steels alloyed with Ni (Co), Mo, W, V, and N are widely used in constructions subjected to cyclic loads at temperatures up to 600 degrees Celsius, in general after quenching from 1100 - 1150 degrees Celsius followed by tempering at 650 - 690 degrees Celsius. Due to long term service exposure at high temperatures, different microstructural changes take place, such as second-phases precipitation, formation of low-angle grain boundaries, as well as internal damage caused by cyclic loads and creep. Specific phase diagrams are presented that can be used to define time periods for reliable operation of parts with given composition, based on the time required for the appearance of second phase particles known to be detrimental to mechanical strength and performance. Restoring thermal treatments to be applied after long time exposure at service conditions, aiming at increasing service life, are also presented and discussed. The combined use of the diagrams and the restoring treatment ensures prediction of a reliable service-life period for components made of these steels.

  6. Corrosion behavior of high-nickel and chromium alloys in natural Baltic seawater

    SciTech Connect

    Birn, J.; Janik-Czachor, M.; Wolowik, A.; Szummer, A.

    1999-10-01

    Effect of Cl{sup {minus}} ion concentration (O M sodium chloride [NaCl] to 2 M NaCl) and temperature (25 C to 75 C) on stability of the passive state of high-Ni and Cr alloys: NI-1 ({approximately} 16% Mo), CR-2 ({approximately} 6.2% Mo), and NI-3 (3.5% Mo) were investigated in acidic and neutral electrolytes in strictly controlled electrochemical conditions. The anodic behavior of the alloys appeared to depend mostly upon Mo content in the alloy. Thus, the NI-1 was the most stable alloy under the applied experimental conditions. The other alloys were also quite resistant, undergoing pitting only at elevated temperatures, at high anodic potentials, and at a chloride concentration not lower than 1 M. In natural Baltic seawater, these alloys did not exhibit any tendency to pitting, in qualitative agreement with the accelerated electrochemical tests. Complementary microscopic and surface analytical (AES) investigations were carried out to correlate the anodic and corrosion behavior of these materials with their composition and structure, and the composition of the passivating films formed at their surfaces.

  7. High precision position control of voice coil motor based on single neuron PID

    NASA Astrophysics Data System (ADS)

    Li, Liyi; Chen, Qiming; Tan, Guangjun; Zhu, He

    2013-01-01

    Voice coil motor(VCM) is widely used in high-speed and high-precision positioning control system in recent years. However, there are system uncertainty, nonlinear, modeling error, and external disturbances in the high-precision positioning control system, traditional PID control method is difficult to achieve precise positioning control. In this paper, a new position control strategy with a single neuron controller which has the capability of self-studying and self-adapting composed with PID controller is put forward, and the feedforward compensator is added to improve the dynamic response of the system in the position loop. Moreover, the disturbance observer is designed to suppress model parameter uncertainty and external disturbance signal in the current loop. In addition, the problem of high precision position control of VCM under the influence of significant disturbances is addressed, which including the gas-lubricated damping, the spring, the back EMF and ripple forces, on the basis, the mathematical model of VCM is established accurately. The simulation results show that this kind of controller can improve the dynamic characteristic and strengthen the robustness of the system, and the current loop with disturbance observer can also restrain disturbance and high frequency.

  8. Remote and high precision step height measurement with an optical fiber multiplexing interferometric system

    NASA Astrophysics Data System (ADS)

    Wang, Yunzhi; Xie, Fang; Ma, Sen; Chen, Liang

    2015-03-01

    An optical fiber multiplexing low coherence and high coherence interferometric system, which includes a Fizeau interferometer as the sensing element and a Michelson interferometer as the demodulating element, is designed for remote and high precision step height measurement. The Fizeau interferometer is placed in the remote field for sensing the measurand, while the Michelson interferometer which works in both modes of low coherence interferometry and high coherence interferometry is employed for demodulating the measurand. The range of the step height is determined by the low coherence interferometry and the value of it is measured precisely by the high coherence interferometry. High precision has been obtained by searching precisely the peak of the low coherence interferogram symmetrically from two sides of the low coherence interferogram and stabilizing the Michelson interferometer with a feedback loop. The maximum step height that could be measured is 6 mm while the measurement resolution is less than 1 nm. The standard deviation of 10 times measurement results of a step height of 1 mm configurated with two gauge blocks is 0.5 nm.

  9. Chitosan-derived carbonaceous material for highly efficient adsorption of chromium (VI) from aqueous solution.

    PubMed

    Shen, Feng; Su, Jialei; Zhang, Xiao; Zhang, Keqiang; Qi, Xinhua

    2016-10-01

    A carbonaceous adsorbent for effectively removing Cr(VI) was synthesized by facile hydrothermal carbonization of chitosan (HTC-chitosan). The prepared HTC-chitosan exhibited good stability in acid solution while the amine groups were retained completely after simple and green hydrothermal carbonization treatment. Structure characteristics of the HTC-chitosan as well as its adsorption behaviors for Cr(VI) in aqueous solution were investigated. Under optimal conditions, the adsorption capacity of the HTC-chitosan for Cr(VI) reached as high as 388.60mgg(-1), which was much higher than that of other materials reported previously. The prepared HTC-chitosan adsorbent could be reused at least five times with adsorption efficiency more than 92%. These results indicate that HTC-chitosan exhibited great superiority for Cr(VI) adsoption from aqueous solution both in terms of the preparation process and adsorption performance.

  10. Chromium(II) Metal-Organic Polyhedra as Highly Porous Materials.

    PubMed

    Park, Jinhee; Perry, Zachary; Chen, Ying-Pin; Bae, Jaeyeon; Zhou, Hong-Cai

    2017-08-23

    Herein we report for the first time the synthesis of Cr(II)-based metal-organic polyhedra (MOPs) and the characterization of their porosities. Unlike the isostructural Cu(II)- or Mo(II)-based MOPs, Cr(II)-based MOPs show unusually high gas uptakes and surface areas. The combination of comparatively robust dichromium paddlewheel units (Cr2 units), cage symmetries, and packing motifs enable these materials to achieve Brunauer-Emmett-Teller surface areas of up to 1000 m(2)/g. Reducing the aggregation of the Cr(II)-based MOPs upon activation makes their pores more accessible than their Cu(II) or Mo(II) counterparts. Further comparisons of surface areas on a molar (m(2)/mol cage) rather than gravimetric (m(2)/g) basis is proposed as a rational method of comparing members of a family of related molecular materials.

  11. Phase Transformations and Microstructural Observations During Subcritical Heat Treatments of a High-Chromium Cast Iron

    NASA Astrophysics Data System (ADS)

    Karantzalis, A. E.; Lekatou, A.; Kapoglou, A.; Mavros, H.; Dracopoulos, V.

    2012-06-01

    In this study, Cr white iron of 18.23 wt.% was subjected to a series of subcritical heat treatments. At both temperatures of 350 and 450 °C, no precipitation of secondary carbides was observed, and the overall microstructure resembles to that of the as-cast condition. At 550 °C, hardness values increased slightly compared to the as-cast values. No evidence of secondary carbide formation was observed. At 650 and 750 °C, extensive-to-complete transformation to pearlite-ferrite structures has occurred. Some evidence of secondary carbide precipitation especially for prolonged treatment periods was not adequate to obstruct the hardness decrease due to the dominating effect of pearlitic-ferritic formation. At 850 °C, secondary carbide precipitation and martensite formation lead to high hardness values.

  12. Chromium speciation and mobility in a high level nuclear waste vadose zone plume

    NASA Astrophysics Data System (ADS)

    Zachara, John M.; Ainsworth, Calvin C.; Brown, Gordon E.; Catalano, Jeffrey G.; McKinley, James P.; Qafoku, Odeta; Smith, Steven C.; Szecsody, James E.; Traina, Sam J.; Warner, Jeffrey A.

    2004-01-01

    Radioactive core samples containing elevated concentrations of Cr from a high level nuclear waste plume in the Hanford vadose zone were studied to asses the future mobility of Cr. Cr(VI) is an important subsurface contaminant at the Hanford Site. The plume originated in 1969 by leakage of self-boiling supernate from a tank containing REDOX process waste. The supernate contained high concentrations of alkali (NaOH ≈ 5.25 mol/L), salt (NaNO 3/NaNO 2 >10 mol/L), aluminate [Al(OH) 4- = 3.36 mol/L], Cr(VI) (0.413 mol/L), and 137Cs + (6.51 × 10 -5 mol/L). Water and acid extraction of the oxidized subsurface sediments indicated that a significant portion of the total Cr was associated with the solid phase. Mineralogic analyses, Cr valence speciation measurements by X-ray adsorption near edge structure (XANES) spectroscopy, and small column leaching studies were performed to identify the chemical retardation mechanism and leachability of Cr. While X-ray diffraction detected little mineralogic change to the sediments from waste reaction, scanning electron microscopy (SEM) showed that mineral particles within 5 m of the point of tank failure were coated with secondary, sodium aluminosilicate precipitates. The density of these precipitates decreased with distance from the source (e.g., beyond 10 m). The XANES and column studies demonstrated the reduction of 29-75% of the total Cr to insoluble Cr(III), and the apparent precipitation of up to 43% of the Cr(VI) as an unidentified, non-leachable phase. Both Cr(VI) reduction and Cr(VI) precipitation were greater in sediments closer to the leak source where significant mineral alteration was noted by SEM. These and other observations imply that basic mineral hydrolysis driven by large concentrations of OH - in the waste stream liberated Fe(II) from the otherwise oxidizing sediments that served as a reductant for CrO 42-. The coarse-textured Hanford sediments contain silt-sized mineral phases (biotite, clinochlore, magnetite, and

  13. New chemistry for the placement of chromium(III)/polymer gels in high-temperature reservoirs

    SciTech Connect

    Lockhart, T.P.; Albonico, P.

    1994-11-01

    Coordination chemistry concepts have been used in the development of Cr[sup +3]/polymer solutions that meet the delayed-gelation requirements for in-depth treatment of high-temperature reservoirs. Use of the malonate complex of Cr[sup +3], Cr(malonate)[sub 3], provides gelation delays at elevated temperature much greater than those obtained with either the hydrated Cr[sup +3] ion or Cr(acetate)[sub 3]. Inclusion of additional, uncomplexed malonate ions in the formulations provides a means for further, and predictable, extension of the gelation time. The gelation delays obtained over the temperature range of 90 to 135 C are equal to or greater than those that can be achieved with the best gelation delay technologies described previously. The dependence of the gelation time on temperature, pH, and the Cr[sup +3] and malonate ion concentrations has been investigated. Preliminary results indicate that the thermal decomposition of the delaying ligand, malonate, plays an important role in determining the gelation rate. The use of a Cr[sup +3] complex of relatively low toxicity rather than the carcinogenic Cr[sup +6] ion to control gelation rate is an attractive feature of the new technology.

  14. Neodymium-rich precipitate phases in a high-chromium ferritic/martensitic steel

    NASA Astrophysics Data System (ADS)

    Shen, Yinzhong; Zhou, Xiaoling; Shang, Zhongxia

    2016-05-01

    Neodymium being considered as nitride forming element has been used in a design of advanced ferritic/martensitic (FM) steels for fossil fired power plants at service temperatures of 630 °C to 650 °C to effectively improve the creep strength of the steels. To fully understand the characteristics of neodymium precipitates in high-Cr FM steels, precipitate phases in an 11Cr FM steel with 0.03 wt% addition of Nd have been investigated by transmission electron microscopy. Three neodymium phases with a face-centered cubic crystal structure and different composition were observed in the steel. They consisted of neodymium carbonitride with an average lattice parameter of 1.0836 nm, Nd-rich carbonitride mainly containing Mn, and Nd-rich MN nitride mainly containing Mn and Co. Other three Nd-rich and Nd-containing phases, which appear to be Nd-Co-Cr/Nd-rich intermetallic compounds and Cr-Fe-rich nitride containing Nd, were also detected in the steel. Nd-relevant precipitates were found to be minor phases compared with M23C6 and Nb/V/Ta-rich MX phases in the steel. The content of Nd in other precipitate phases was very low. Most of added Nd is considered to be present as solid solution in the matrix of the steel.

  15. Effect of chromium on low-temperature deformation of high-purity iron

    NASA Technical Reports Server (NTRS)

    Kelley, M. J.; Stoloff, N. S.

    1976-01-01

    A series of very low interstitial Fe-Cr alloys containing 0, 1, 3, 5, and 10 wt% Cr were prepared by vacuum melting and fabricated under argon to 1.83 mm diam wires exposed in an alumina system to wet hydrogen for 200 h at 1423 K followed by 1000 h in ZrH2-purified hydrogen at 1573 K. The wires were then transverse-rolled into thin sheet and cut into tensile specimens subjected to electropolishing and strained to fracture in a series of cryogenic baths ranging from 4.2 K to room temperature. It is shown that small Cr additions lower the twinning stress so that yielding occurs by twinning rather than by slip. Cr in amounts up to 10 wt% has little effect on the yield strength of high-purity Fe between 147 and 300 K, and ductility is not greatly affected at any test temperature. Higher solute contents provide appreciable strengthening only at temperatures of 112 K and below.

  16. Centroiding Experiment for Determining the Positions of Stars with High Precision

    NASA Astrophysics Data System (ADS)

    Yano, T.; Araki, H.; Hanada, H.; Tazawa, S.; Gouda, N.; Kobayashi, Y.; Yamada, Y.; Niwa, Y.

    2010-12-01

    We have experimented with the determination of the positions of star images on a detector with high precision such as 10 microarcseconds, required by a space astrometry satellite, JASMINE. In order to accomplish such a precision, we take the following two procedures. (1) We determine the positions of star images on the detector with the precision of about 0.01 pixel for one measurement, using an algorithm for estimating them from photon weighted means of the star images. (2) We determine the positions of star images with the precision of about 0.0001-0.00001 pixel, which corresponds to that of 10 microarcseconds, using a large amount of data over 10000 measurements, that is, the error of the positions decreases according to the amount of data. Here, we note that the procedure 2 is not accomplished when the systematic error in our data is not excluded adequately even if we use a large amount of data. We first show the method to determine the positions of star images on the detector using photon weighted means of star images. This algorithm, used in this experiment, is very useful because it is easy to calculate the photon weighted mean from the data. This is very important in treating a large amount of data. Furthermore, we need not assume the shape of the point spread function in deriving the centroid of star images. Second, we show the results in the laboratory experiment for precision of determining the positions of star images. We obtain that the precision of estimation of positions of star images on the detector is under a variance of 0.01 pixel for one measurement (procedure 1). We also obtain that the precision of the positions of star images becomes a variance of about 0.0001 pixel using about 10000 measurements (procedure 2).

  17. Active-passive hybrid piezoelectric actuators for high-precision hard disk drive servo systems

    NASA Astrophysics Data System (ADS)

    Chan, Kwong Wah; Liao, Wei-Hsin

    2006-03-01

    Positioning precision is crucial to today's increasingly high-speed, high-capacity, high data density, and miniaturized hard disk drives (HDDs). The demand for higher bandwidth servo systems that can quickly and precisely position the read/write head on a high track density becomes more pressing. Recently, the idea of applying dual-stage actuators to track servo systems has been studied. The push-pull piezoelectric actuated devices have been developed as micro actuators for fine and fast positioning, while the voice coil motor functions as a large but coarse seeking. However, the current dual-stage actuator design uses piezoelectric patches only without passive damping. In this paper, we propose a dual-stage servo system using enhanced active-passive hybrid piezoelectric actuators. The proposed actuators will improve the existing dual-stage actuators for higher precision and shock resistance, due to the incorporation of passive damping in the design. We aim to develop this hybrid servo system not only to increase speed of track seeking but also to improve precision of track following servos in HDDs. New piezoelectrically actuated suspensions with passive damping have been designed and fabricated. In order to evaluate positioning and track following performances for the dual-stage track servo systems, experimental efforts are carried out to implement the synthesized active-passive suspension structure with enhanced piezoelectric actuators using a composite nonlinear feedback controller.

  18. An optical fiber multiplexing interferometric system for measuring remote and high precision step height

    NASA Astrophysics Data System (ADS)

    Wang, Yunzhi; Xie, Fang; Ma, Sen; Chen, Liang

    2015-02-01

    In this paper, an optical fiber multiplexing interferometric system including a Fizeau interferometer and a Michelson interferometer is designed for remote and high precision step height measurement. The Fizeau interferometer which is inserted in the remote sensing field is used for sensing the measurand, while the Michelson interferometer which is stabilized by a feedback loop works in both modes of low coherence interferometry and high coherence interferometry to demodulate the measurand. The range of the step height is determined by the low coherence interferometry and the value of it is measured precisely by the high coherence interferometry. High precision has been obtained by using the symmetrical peak-searching method to address the peak of the low coherence interferogram precisely and stabilizing the Michelson interferometer with a feedback loop. The maximum step height that could be measured is 6 mm while the measurement resolution is less than 1 nm. The standard deviation of 10 times measurement results of a step height of 1 mm configurated with two gauge blocks is 0.5 nm.

  19. [Chromium and insulin resistance].

    PubMed

    Kleefstra, N; Bilo, H J; Bakker, S J; Houweling, S T

    2004-01-31

    Since as early as the 50s of the last century, it has been known that chromium is essential for normal glucose metabolism. Too little chromium in the diet may lead to insulin resistance. However, there is still no standard against which chromium deficiency can be established. Nevertheless, chromium supplements are becoming increasingly popular. Various systematic reviews have been unable to demonstrate any effects of chromium on glycaemic regulation (possibly due partly to the low dosages used), but there is a slight reduction in body weight averaging 1 kg. In a double-blind randomised placebo-controlled trial in a Chinese population with type-2 diabetes mellitus, supplementation with 1000 micrograms of chromium led to a fall in the glycosylated haemoglobin level (HbA1c) by 2%. Toxic effects of chromium are seldom seen; recently, however, the safety of one of the dosage forms of chromium, chromium picolinate, has been questioned. One should be aware that individual patients with type-2 diabetes mellitus may have an increased risk of hypoglycaemic episodes when taking chromium supplements as self-medication.

  20. Mechanical behavior and brittle-ductile transition of high-chromium martensitic steel

    NASA Astrophysics Data System (ADS)

    Odnobokova, M. V.; Kipelova, A. Yu.; Belyakov, A. N.; Kaibyshev, R. O.

    2016-04-01

    The article presents data on the static tensile tests and dynamic impact-toughness tests of a highchromium martensitic 10Kh9V1M1FBR steel (0.12 wt % C, 9.8 wt % Cr, 0.93 wt % W, 1.01 wt % Mo, 0.2 wt % V, 0.05 wt % Nb, 0.05 wt % N, 0.003 wt % B, 0.36 wt % Mn, 0.2 wt % Ni, 0.06 wt % Si, 0.01 wt % P, 0.008 wt % S, 0.02 wt % Cu, 0.1 wt % Co, 0.015 wt % Al, and the remainder is Fe) in the temperature range from 20 to-196°C. In the case of static loading, a reduction in the temperature leads to an increase in the strength characteristics; upon a drop in the temperature from 20 to-100°C, the plasticity also increases. This is connected with the fact that the ductile fracture remains the basic mechanism down to cryogenic temperatures. The brittle-ductile transition related to the transition from ductile intragranular fracture to quasibrittle one is observed at-45°C. The steel exhibits high impact toughness to the temperature of-60°C ( KCV -60 = 95 J/cm2), at which the fraction of the ductile component in fracture is equal to 20%. At 80°C, the impact toughness decreases down to critical values (30 J/cm2), which correlates with the decrease in the fraction of the ductile component on the fracture surface down to 1%. The further decrease in the impact toughness down to 10 J/cm2 at-196°C is related to the transition from intragranular to intergranular brittle fracture.

  1. High-Precision Calibration of a Weld-On-The-Fly-System

    NASA Astrophysics Data System (ADS)

    Emmelmann, Claus; Schenk, Kerstin; Wollnack, Jörg; Kirchhoff, Marc

    Since 20 years the importance of laser based material processing increases constantly due to its significant higher process speed in comparison to conventional processing technologies. A scanner system for laser-remote-welding mounted on a robot hand to achieve more freedom in positioning the laser spot has been investigated. Additionally the scanner head contains two fixed cameras for measurements and process monitoring. To perform required measurements with maximum accuracy the allover system has to be calibrated precise. Therefore a combination of video metric measurement system and a laser tracker has been used. This paper depict this high-precision calibration process and shows reachable accuracies.

  2. Development and Utilization of High Precision Digital Elevation Data taken by Airborne Laser Scanner

    NASA Astrophysics Data System (ADS)

    Akutsu, Osamu; Ohta, Masataka; Isobe, Tamio; Ando, Hisamitsu, Noguchi, Takahiro; Shimizu, Masayuki

    2005-03-01

    Disasters caused by heavy rain in urban areas bring a damage such as chaos in the road and railway transport systems, power failure, breakdown of the telephone system and submersion of built up areas, subways and underground shopping arcades, etc. It is important to obtain high precision elevation data which shows the detailed landform because a slight height difference affects damages by flood very considerably. Therefore, The Geographical Survey Institute (GSI) is preparing 5m grid digital terrain model (DTM) based on precise ground elevation data taken by using airborne laser scanner. This paper describes the process and an example of the use of a 5m grid digital data set.

  3. Microplasma patterning of bonded microchannels using high-precision "injected" electrodes.

    PubMed

    Priest, Craig; Gruner, Philipp J; Szili, Endre J; Al-Bataineh, Sameer A; Bradley, James W; Ralston, John; Steele, David A; Short, Robert D

    2011-02-07

    A rapid, high-precision method for localised plasma-treatment of bonded PDMS microchannels is demonstrated. Patterned electrodes were prepared by injection of molten gallium into preformed microchannel guides. The electrode guides were prepared without any additional fabrication steps compared to conventional microchannel fabrication. Alignment of the "injected" electrodes is precisely controlled by the photomask design, rather than positioning accuracy of alignment tools. Surface modification is detected using a fluorescent dye (Rhodamine B), revealing a well-defined micropattern with regions less than 100 µm along the length of the microchannel.

  4. Direct oxidation of guanine and 7,8-dihydro-8-oxoguanine in DNA by a high-valent chromium complex: a possible mechanism for chromate genotoxicity.

    PubMed

    Sugden, K D; Campo, C K; Martin, B D

    2001-09-01

    Intracellular reductive activation of the human carcinogen chromate, Cr(VI), is a necessary step in the formation of DNA lesions that lead to cancer. Reductive activation forms the transient metastable high-valent oxidation state of Cr(V) as a precursor to the final intracellularly stable oxidation state, Cr(III). In this study, we have used a model high-valent Cr(V) complex, N,N'-ethylenebis(salicylideneanimato)oxochromium(V), Cr(V)-Salen, to probe the mechanism of interaction between this oxidation state of chromium and DNA. This interaction was found to be specific toward the oxidation of the nucleic acid base guanine in unmodified single- and double-stranded oligonucleotides as measured by an increased level of DNA strand cleavage at these sites following piperidine treatment. Replacement of a single guanine residue in DNA with a more readily oxidized 7,8-dihydro-8-oxoguanine (8-oxo-G) base allowed for site-specific oxidation at this modified site within the DNA strand by the Cr(V)-Salen complex. HPLC and ESI-mass spectrometry were used to identify the modified guanine base lesions formed in the reaction of this high-valent chromium complex with the 8-oxo-G-containing DNA substrate. Two of these modified base lesions, identified as guanidinohydantoin and spiroiminodihydantoin, were found in the reaction of the Cr(V)-Salen complex with 8-oxo-G-modified DNA, while only one, spiroiminodihydantoin, was formed from oxidation of the 8-oxo-G nucleoside. A primer extension assay using the exo(-) Klenow fragment demonstrated polymerase arrest at the site of these base modifications as well as a high degree of misincorporation of adenine opposite the site of modification. These results suggest that mutations arising from G --> T transversions would predominate with these lesions. The mechanism of damage and base oxidation products for the interaction between high-valent chromium and DNA described herein may be relevant to the in vivo formation of DNA damage leading to

  5. High-dose, high-precision treatment options for boosting cancer of the nasopharynx.

    PubMed

    Levendag, Peter C; Lagerwaard, Frank J; de Pan, Connie; Noever, Inge; van Nimwegen, Arent; Wijers, Oda; Nowak, Peter J C M

    2002-04-01

    The aim of the study is to define the role and type of high-dose, high-precision radiation therapy for boosting early staged T1,2a, but in particular locally advanced, T2b-4, nasopharyngeal cancer (NPC). Ninety-one patients with primary stage I-IVB NPC, were treated between 1991 and 2000 with 60-70Gy external beam radiation therapy (ERT) followed by 11-18Gy endocavitary brachytherapy (ECBT) boost. In 1996, for stage III-IVB disease, cisplatinum (CDDP)-based neoadjuvant chemotherapy (CHT) was introduced per protocol. Patients were analyzed for local control and overall survival. For a subset of 18 patients, a magnetic resonance imaging (MRI) scan at 46Gy was obtained. After matching with pre-treatment computed tomogram, patients (response) were graded into four categories; i.e. LD (T1,2a, with limited disease, i.e. disease confined to nasopharynx), LRD (T2b, with limited residual disease), ERD (T2b, with extensive residual disease), or patients initially diagnosed with T3,4 tumors. Dose distributions for ECBT (Plato-BPS v. 13.3, Nucletron) were compared to parallel-opposed three-dimensional conformal radiation therapy (Cadplan, Varian Dosetek v. 3.1), intensity modulated radiation therapy (IMRT) (Helios, Varian) and stereotactic radiotherapy (SRT) (X-plan, Radionics v. 2.02). For stage T1,2N0,1 tumors, at 2 years local control of 96% and overall survival of 80% were observed. For the poorest subset of patients, well/moderate/poorly differentiated T3,4 tumors, local control and overall survival at 2 years with CHT were 67 and 67%, respectively, vs. local control of 20% and overall survival of 12% without CHT. For LD and LRD, conformal target coverage and optimal sparing can be obtained with brachytherapy. For T2b-ERD and T3,4 tumors, these planning goals are better achieved with SRT and/or IMRT. The dosimetric findings, ease of application of the brachytherapy procedure, and the clinical results in early staged NPC, necessitates ERT combined with brachytherapy boost

  6. High precision measurements of the diamond Hugoniot in and above the melt region

    SciTech Connect

    Hicks, D; Boehly, T; Celliers, P; Bradley, D; Eggert, J; McWilliams, R S; Collins, G

    2008-08-05

    High precision laser-driven shock wave measurements of the diamond principal Hugoniot have been made at pressures between 6 and 19 Mbar. Shock velocities were determined with 0.3-1.1% precision using a velocity interferometer. Impedance matching analysis, incorporating systematic errors in the equation-of-state of the quartz standard, was used to determine the Hugoniot with 1.2-2.7% precision in density. The results are in good agreement with published ab initio calculations which predict a small negative melt slope along the Hugoniot, but disagree with previous laser-driven shock wave experiments which had observed a large density increase in the melt region. In the extensive solid-liquid coexistence regime between 6 and 10 Mbar these measurements indicate that the mixed phase may be slightly more dense than would be expected from a simple interpolation between liquid and solid Hugoniots.

  7. High precision tuning of state for memristive devices by adaptable variation-tolerant algorithm

    NASA Astrophysics Data System (ADS)

    Alibart, Fabien; Gao, Ligang; Hoskins, Brian D.; Strukov, Dmitri B.

    2012-02-01

    Using memristive properties common for titanium dioxide thin film devices, we designed a simple write algorithm to tune device conductance at a specific bias point to 1% relative accuracy (which is roughly equivalent to seven-bit precision) within its dynamic range even in the presence of large variations in switching behavior. The high precision state is nonvolatile and the results are likely to be sustained for nanoscale memristive devices because of the inherent filamentary nature of the resistive switching. The proposed functionality of memristive devices is especially attractive for analog computing with low precision data. As one representative example we demonstrate hybrid circuitry consisting of an integrated circuit summing amplifier and two memristive devices to perform the analog multiply-and-add (dot-product) computation, which is a typical bottleneck operation in information processing.

  8. Acoustic grating fringe projector for high-speed and high-precision three-dimensional shape measurements.

    PubMed

    Yin, Xuebing; Zhao, Huijie; Zeng, Junyu; Qu, Yufu

    2007-05-20

    A new acoustic grating fringe projector (AGFP) was developed for high-speed and high-precision 3D measurement. A new acoustic grating fringe projection theory is also proposed to describe the optical system. The AGFP instrument can adjust the spatial phase and period of fringes with unprecedented speed and accuracy. Using rf power proportional-integral-derivative (PID) control and CCD synchronous control, we obtain fringes with fine sinusoidal characteristics and realize high-speed acquisition of image data. Using the device, we obtained a precise phase map for a 3D profile. In addition, the AGFP can work in running fringe mode, which could be applied in other measurement fields.

  9. High-precision branching ratio measurement for the superallowed {beta}{sup +} emitter {sup 62}Ga

    SciTech Connect

    Finlay, P.; Svensson, C. E.; Bandyopadhyay, D.; Grinyer, G. F.; Hyland, B.; Leach, K. G.; Phillips, A. A.; Schumaker, M. A.; Wong, J.; Ball, G. C.; Chakrawarthy, R. S.; Hackman, G.; Kanungo, R.; Morton, A. C.; Pearson, C. J.; Savajols, H.; Leslie, J. R.; Towner, I. S.; Austin, R. A. E.; Chaffey, A.

    2008-08-15

    A high-precision branching ratio measurement for the superallowed {beta}{sup +} decay of {sup 62}Ga was performed at the Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. The 8{pi} spectrometer, an array of 20 high-purity germanium detectors, was employed to detect the {gamma} rays emitted following Gamow-Teller and nonanalog Fermi {beta}{sup +} decays of {sup 62}Ga, and the SCEPTAR plastic scintillator array was used to detect the emitted {beta} particles. Thirty {gamma} rays were identified following {sup 62}Ga decay, establishing the superallowed branching ratio to be 99.858(8)%. Combined with the world-average half-life and a recent high-precision Q-value measurement for {sup 62}Ga, this branching ratio yields an ft value of 3074.3{+-}1.1 s, making {sup 62}Ga among the most precisely determined superallowed ft values. Comparison between the superallowed ft value determined in this work and the world-average corrected Ft value allows the large nuclear-structure-dependent correction for {sup 62}Ga decay to be experimentally determined from the CVC hypothesis to better than 7% of its own value, the most precise experimental determination for any superallowed emitter. These results provide a benchmark for the refinement of the theoretical description of isospin-symmetry breaking in A{>=}62 superallowed decays.

  10. Development of high precision laser measurement to Space Debris and Applications in SHAO

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongping; Chen, Juping; Xiong, Yaoheng; Han, Xingwei

    2016-07-01

    Artificial space debris has become the focus during the space exploration because of producing the damage for the future active spacecrafts and high precision measurement for space debris are required for debris surveillance and collision avoidance. Laser ranging technology is inherently high accurate and will play an important role in precise orbit determination, accurate catalog of space debris. Shanghai Astronomical Observatory (SHAO) of CAS, has been developing the technology of laser measurement to space debris for several years. According to characteristics of laser echoes from space debris and the experiences of relevant activities, high repetition rate, high power laser system and low dark noise APD detector with high quantum efficiency and high transmissivity of narrow bandwidth spectral filter are applied to laser measurement to space debris in SHAO. With these configurations, great achievements of laser measurement to space debris are made with hundreds of passes of laser data from space debris in the distance between 500km and 2500km with Radar Cross Section (RCS) of more than 10 m^{2} to less than 0.5m^{2} at the measuring precision of less than 1m (RMS). For better application of laser ranging technology, Chinese Space Debris Observation network, consisting of Shanghai, Changchun and Kunming station, has been preliminary developed and the coordinated observation has been performed to increase the measuring efficiency for space debris. It is referred from data that laser ranging technology can be as the essential high accuracy measurement technology in the study of space debris.

  11. A high-precision method for measurement of paleoatmospheric CO2 in small polar ice samples

    NASA Astrophysics Data System (ADS)

    Ahn, Jinho; Brook, Edward J.; Howell, Kate

    We describe a high-precision method, now in use in our laboratory, for measuring the CO2 mixing ratio of ancient air trapped in polar ice cores. Occluded air in ice samples weighing ˜8-15 g is liberated by crushing with steel pins at -35°C and trapped at -263°C in a cryogenic cold trap. CO2 in the extracted air is analyzed using gas chromatography. Replicate measurements for several samples of high-quality ice from the Siple Dome and Taylor Dome Antarctic ice cores have pooled standard deviations of <0.9 ppm. This high-precision technique is directly applicable to high-temporal-resolution studies for detection of small CO2 variations, for example CO2 variations of a few parts per million on millennial to decadal scales.

  12. Chromium toxicity in plants.

    PubMed

    Shanker, Arun K; Cervantes, Carlos; Loza-Tavera, Herminia; Avudainayagam, S

    2005-07-01

    Due to its wide industrial use, chromium is considered a serious environmental pollutant. Contamination of soil and water by chromium (Cr) is of recent concern. Toxicity of Cr to plants depends on its valence state: Cr(VI) is highly toxic and mobile whereas Cr(III) is less toxic. Since plants lack a specific transport system for Cr, it is taken up by carriers of essential ions such as sulfate or iron. Toxic effects of Cr on plant growth and development include alterations in the germination process as well as in the growth of roots, stems and leaves, which may affect total dry matter production and yield. Cr also causes deleterious effects on plant physiological processes such as photosynthesis, water relations and mineral nutrition. Metabolic alterations by Cr exposure have also been described in plants either by a direct effect on enzymes or other metabolites or by its ability to generate reactive oxygen species which may cause oxidative stress. The potential of plants with the capacity to accumulate or to stabilize Cr compounds for bioremediation of Cr contamination has gained interest in recent years.

  13. A high-precision tunable millimeter-wave photonic LO reference for the ALMA telescope

    NASA Astrophysics Data System (ADS)

    Shillue, W.; Grammer, W.; Jacques, C.; Meadows, H.; Castro, J.; Banda, J.; Treacy, R.; Masui, Y.; Brito, R.; Huggard, P.; Ellison, B.; Cliche, J.-F.; Ayotte, S.; Babin, A.; Costin, F.; Latrasse, C.; Pelletier, F.; Picard, M.-J.; Poulin, M.; Poulin, P.

    2013-06-01

    The Atacama Large Millimeter Array is a radio telescope array of 66 antennas designed for high performance scientific imaging, covering a frequency range of 27-950 GHz. Each antenna has a front end with ten receiving bands, and each band has a local oscillator which is synchronized between all antennas. We describe a high precision tunable millimeter-wave photonic local oscillator reference system, which is used as the synchronizing reference for all ten bands on each receiver.

  14. Development of the Portable Synchrotron MIRRORCLE-CV for High Precision Non-Destructive Testing

    SciTech Connect

    Hasegawa, Daisuke; Toyosugi, Norio; Noh, Young Deok; Yamada, Takanori; Morita, Masaki; Mantey, Edward; Masaoka, Sei; Yamada, Hironari

    2007-01-19

    We started the development of the portable synchrotron MIRRORCLE-CV series, which provides a high quality x-ray beam for high precision non-destructive testing (NDT). Computer simulations for the magnetic field design and electron dynamics reveal that the outer diameter of the synchrotron magnet can be as small as 30 cm. This synchrotron size approaches that of a conventional x-ray tube.

  15. High-Precision 40Ar/39Ar dating of the Deccan Traps

    NASA Astrophysics Data System (ADS)

    Sprain, C. J.; Renne, P. R.; Richards, M. A.; Self, S.; Vanderkluysen, L.; Pande, K.; Morgan, L. E.; Cosca, M. A.

    2015-12-01

    The Deccan Traps (DT) have been strongly implicated over the past thirty years as a potential cause of the mass extinctions at the Cretaceous-Paleogene boundary (KPB). While a broad coincidence between the DT eruptions and the KPB is increasingly clear, variables such as tempo, volume of eruptions, and amount of associated climate-modifying volatiles, are too poorly constrained to properly assess causality. In order to appropriately test whether the DT played a role in the mass extinctions a high-precision geochronologic framework defining the timing and tempo of volcanic eruptions is needed. Recent high-precision U/Pb dating of zircons from inferred paleosols (red boles) and melt segregation horizons is the only available geochronology of the DT that is sufficiently precise to resolve age differences of less than 100 ka (Schoene et al., 2015). While this technique can achieve high-precision dates for individual zircon crystals, protracted age distributions may not include the actual eruption age. Moreover, the applicability of U/Pb dating in the DT is limited as suitable material is only sporadically present and therefore the technique is unlikely to achieve the resolution necessary to assess the tempo of DT eruptions. To mediate these limitations, we present new high-precision 40Ar/39Ar ages for plagioclase separated from the lava flows sampled from each of ten chemostratigraphically-defined formations within the Western Ghats. Multiple (N = 1-4) plateau ages from each sample and detailed neutron fluence monitoring during irradiation yield ages with precision commonly better than 100 ka (1 sigma). Results provide the first precise location of the KPB within the DT eruption sequence, which approximately coincides with major changes in eruption frequency, flow-field volumes, extent of crustal contamination, and degree of fractionation. Collectively, these results suggest that a state shift occurred in the DT magma system within ~50 ka of the Chicxulub impact

  16. High-precision optical systems with inexpensive hardware: a unified alignment and structural design approach

    NASA Astrophysics Data System (ADS)

    Winrow, Edward G.; Chavez, Victor H.

    2011-09-01

    High-precision opto-mechanical structures have historically been plagued by high costs for both hardware and the associated alignment and assembly process. This problem is especially true for space applications where only a few production units are produced. A methodology for optical alignment and optical structure design is presented which shifts the mechanism of maintaining precision from tightly toleranced, machined flight hardware to reusable, modular tooling. Using the proposed methodology, optical alignment error sources are reduced by the direct alignment of optics through their surface retroreflections (pips) as seen through a theodolite. Optical alignment adjustments are actualized through motorized, sub-micron precision actuators in 5 degrees of freedom. Optical structure hardware costs are reduced through the use of simple shapes (tubes, plates) and repeated components. This approach produces significantly cheaper hardware and more efficient assembly without sacrificing alignment precision or optical structure stability. The design, alignment plan and assembly of a 4" aperture, carbon fiber composite, Schmidt-Cassegrain concept telescope is presented.

  17. High precision mobile location framework and its service based on virtual reference station of GPS

    NASA Astrophysics Data System (ADS)

    Liu, Chun; Sun, Liangyu; Yao, Lianbi

    2008-10-01

    The wireless communication technology and space technology are synchronously developed in recent years, which bring up the development of location based service (LBS). At present, many location technology methods were developed. However, all these methods can only provide a relative poor location precision and depend on high cost. The technology of Virtual Reference Station (VRS) of GPS is then involved in this paper. One of the objective in this paper is aim to give the LBS position structure to improve the mobile location position when a mobile position instrument is connected with VRS network. The cheaper GPS built-in Personal Designer Aid (PDA) is then used to achieve a higher precision by using RTCM data from existing VRS network. In order to obtain a high precision position when using the low-cost GPS receiver as a rover, the infrusture of the mobile differential correction system is then put forward. According to network transportation of RTCM via internet protocol (NTRIP), the message is communicated through wireless network, such as GPRS, CDMA and so on. The rough coordinate information is sent to VRS control center continuously, and then the VRS correction information is replied to rover in the data format of RTCM3.1. So the position will be updated based on mathematic solution after the decoding of RTCM3.1 data. The thought of LBS position can improve the precision, and can speed the LBS.

  18. Development and simulation of microfluidic Wheatstone bridge for high-precision sensor

    NASA Astrophysics Data System (ADS)

    Shipulya, N. D.; Konakov, S. A.; Krzhizhanovskaya, V. V.

    2016-08-01

    In this work we present the results of analytical modeling and 3D computer simulation of microfluidic Wheatstone bridge, which is used for high-accuracy measurements and precision instruments. We propose and simulate a new method of a bridge balancing process by changing the microchannel geometry. This process is based on the “etching in microchannel” technology we developed earlier (doi:10.1088/1742-6596/681/1/012035). Our method ensures a precise control of the flow rate and flow direction in the bridge microchannel. The advantage of our approach is the ability to work without any control valves and other active electronic systems, which are usually used for bridge balancing. The geometrical configuration of microchannels was selected based on the analytical estimations. A detailed 3D numerical model was based on Navier-Stokes equations for a laminar fluid flow at low Reynolds numbers. We investigated the behavior of the Wheatstone bridge under different process conditions; found a relation between the channel resistance and flow rate through the bridge; and calculated the pressure drop across the system under different total flow rates and viscosities. Finally, we describe a high-precision microfluidic pressure sensor that employs the Wheatstone bridge and discuss other applications in complex precision microfluidic systems.

  19. A study on using image serving technology for high precision mechanical positioning

    NASA Astrophysics Data System (ADS)

    Lin, Chuen-Horng; Hsiao, Muh-Don; Lai, Kuo-Jung

    2016-12-01

    This paper focused on using image server technology for high precision mechanical positioning. Rapid and precise positioning systems depend on the correct positions of CCD (Charge Coupled Device) video cameras, as well as on pattern matching modes. This study deals with four different positions captured by an automatic detection system employing a CCD video camera. According to a variety of hybrid image registration systems, this study proposes an entire set of methods for achieving optimal hybrid pattern matching. First, the four different position detections captured by the CCD video camera in low-resolution were examined. Next, the original position detection was carried out in high-resolution, in order to derive a precise set of CCD video camera positions. The fiducial mark (FM) was then divided into two types in the optimal option for pattern matching: the "fiducial mark" and "non-fiducial mark", which were then used for sampling. The automatic detection method is able to achieve the first pattern matching detection for recognized images. Unrecognized images or images that cannot have an FM were subjected to fine pattern matching detection. When it is not possible to find more than one FM after the proposed detection method, this suggests that the position of the CCD video camera should be reset. In this paper, the results of the experiment regarding the CCD camera precision location and the segmentation of fiducial patterns or insignificant fiducial patterns can detect and segment more unique areas and areas with unique features.

  20. Process influences and correction possibilities for high precision injection molded freeform optics

    NASA Astrophysics Data System (ADS)

    Dick, Lars; Risse, Stefan; Tünnermann, Andreas

    2016-08-01

    Modern injection molding processes offer a cost-efficient method for manufacturing high precision plastic optics for high volume applications. Besides form deviation of molded freeform optics, internal material stress is a relevant influencing factor for the functionality of a freeform optics in an optical system. This paper illustrates dominant influence parameters of an injection molding process relating to form deviation and internal material stress based on a freeform demonstrator geometry. Furthermore, a deterministic and efficient way for 3D mold correcting of systematic, asymmetrical shrinkage errors is shown to reach micrometer range shape accuracy at diameters up to 40 mm. In a second case, a stress-optimized parameter combination using unusual molding conditions was 3D corrected to reach high precision and low stress freeform polymer optics.

  1. Chromium levels in spices and aromatic herbs.

    PubMed

    Garcia, E; Cabrera, C; Lorenzo, M L; López, M C

    2000-02-28

    We determined the presence of chromium in a total of 72 samples of 17 different spices and aromatic herbs. Electrothermal atomization atomic absorption spectrometry (ETA-AAS) was used to determine Cr content in the samples mineralized with HNO3 and V2O5. The analytical characteristics of the proposed method were tested, and the accuracy and precision was also verified against an NBS-certified reference material. Chromium concentrations ranged from not detectable to 1.42 micrograms/g (dry wt.) and Cr presence was detected in 95% of samples. Spices and aromatic herbs are widely consumed in the Spanish diet and in the Mediterranean diet, in general.

  2. High Precision Isotope Analyses Using Multi-Collector SIMS: Applications to Earth and Planetary Science.

    NASA Astrophysics Data System (ADS)

    Kita, N. T.; Ushikubo, T.; Valley, J. W.

    2008-05-01

    The CAMECA IMS-1280 large radius, multicollector ion microprobe at the Wisc-SIMS National Facility is capable of high accuracy and precision for in situ analysis of isotope ratios. With improved hardware stability and software capability, high precision isotope analyses are routinely performed, typically 5 min per spot. We have developed analytical protocols for stable isotope analyses of oxygen, carbon, Mg, Si and Sulfur using multi-collector Faraday Cups (MCFC) and achieved precision of 0.1-0.2 ‰ (1SD) from a typically 10μm spot analyses. A number of isotopically homogeneous mineral standards have been prepared and calibrated in order to certify the accuracy of analyses in the same level. When spatial resolution is critical, spot size is reduced down to sub- μm for δ 18O to obtain better than 0.5‰ (1SD) precision by using electron multiplier (EM) on multi-collection system. Multi-collection EM analysis is also applied at 10 ppm level to Li isotope ratios in zircon with precision better than 2‰ (1SD). A few applications will be presented. (1) Oxygen three isotope analyses of chondrules in ordinary chondrites revealed both mass dependent and mass independent oxygen isotope fractionations among chondrules as well as within individual chondrules. The results give constraints on the process of chondrule formation and origin of isotope reservoirs in the early solar system. (2) High precision 26Al-26Mg (half life of 0.73 Ma) chronology is applied to zoned melilite and anorthite from Ca, Al-rich inclusions (CAI) in Leoville meteorite, and a well-defined internal isochron is obtained. The results indicate the Al- Mg system was remained closed within 40ky of the crystallization of melilite and anorthite in this CAI. (3) Sub- μm spot analyses of δ18O in isotopically zoned zircon from high-grade metamorphism reveals a diffusion profile of ~6‰ over 2μm, indicating slow diffusion of oxygen in zircon. This result also implies that old Archean detrital zircons (> 4

  3. Precision of volumetric assessment of proximal femur microarchitecture from high-resolution 3T MRI.

    PubMed

    Hotca, Alexandra; Ravichandra, Shreyas; Mikheev, Artem; Rusinek, Henry; Chang, Gregory

    2015-01-01

    To evaluate the precision of measures of bone volume and bone volume fraction derived from high-resolution 3T MRI of proximal femur bone microarchitecture using non-uniformity correction. This HIPAA compliant, institutional review board approved study was conducted on six volunteers (mean age 56 ± 13 years), and written informed consent was obtained. All volunteers underwent a 3T FLASH MRI hip scan at three time points: baseline, second scan same day (intra-scans), and third scan one week later (inter-scans). Segmentation of femur images and values for total proximal femur volume (T), bone volume (B), and bone volume fraction (BVF) were calculated using in-house developed software, FireVoxel. Two types of non-uniformity corrections were applied to images (N3 and BiCal). Precision values were calculated using absolute percent error (APE). Statistical analysis was carried out using one-sample one-sided t test to observe the consistency of the precision and paired t test to compare between the various methods and scans. No significant differences in bone volume measurements were observed for intra- and inter-scans. When using non-uniformity correction and assessing all subjects uniformly at the level of the lesser trochanter, precision values overall improved, especially significantly (p < 0.05) when measuring bone volume, B . B values using the combination of N3 or BiCal with CLT had a significant consistent APE values of less than 2.5 %, while BVF values were all consistently and significantly lower than 2.5 % APE. Our results demonstrate the precision of high-resolution 3D MRI measures were comparable to that of dual-energy X-ray absorptiometry. Additional corrections to the analysis technique by cropping at the lesser trochanter or using non-uniformity corrections helped to improve precision. The high precision values from these MRI scans provide evidence for MRI of the proximal femur as a promising tool for osteoporosis diagnosis and treatment.

  4. Effect of alloying elements on the composition of carbide phases and mechanical properties of the matrix of high-carbon chromium-vanadium steel

    NASA Astrophysics Data System (ADS)

    Titov, V. I.; Tarasenko, L. V.; Utkina, A. N.

    2017-01-01

    Based on the results of phase physicochemical analysis of high-carbon chromium-vanadium steel, the predominant type of carbide that provides high wear resistance has been established, and its amount and amount of carbon in martensite have been determined. Data on the composition and the amount of carbide phase and on the chemical composition of the martensite of high-carbon steel have been obtained, which allows determination of the alloying-element concentration limits. The mechanical testing of heats of a chosen chemical composition has been carried out after quenching and low-temperature tempering. The tests have demonstrated benefits of new steel in wear resistance and bending strength with the fatigue strength being retained, compared to steels subjected to cementation. The mechanism of secondary strengthening of the steel upon high-temperature tempering has been revealed. High-temperature tempering can be applied to articles that are required to possess both high wear resistance and heat resistance.

  5. Chromium-51 calibrating neutrino source

    SciTech Connect

    Demchenko, N.F.; Karasev, V.I.; Karelin, E.A.

    1993-12-31

    The problem for measurement of the sun neutrino flux is resolved at the specially made Baksansk neutrino telescope and calls for calibration of registration system. For this a man made neutrino source is required with the known yield of particles and intensity comparable with the intensity of the measured subject. The most suitable radionuclide for production of this source is chromium-51 the radionuclide decay of which is accompanied with neutrino radiation. At the Research Institute of Atomic Reactors (in Dimitrovgrad) the production technology is developed as well as the closed chromium-51 neutrino source is made of 4 x 10{sup 5} Ci activity. The parts of active source made in the form of core of metallic isotope-enriched chromium were irradiated in the high flux neutron trap of the SM-2 reactor. The sources were subsequently assembled at the shield cells with remote equipment application. The source was certificated as a special form radioactive material. Due to low half-life of chromium-51 (T 1/2 - 27 hours) all the operations on assembly, certification and delivery of source to the Baksansk Laboratory were performed at the earliest possible date (less than 3 days).

  6. High-precision reflectometry of multilayer coatings for extreme ultraviolet lithography

    SciTech Connect

    Wedowski, M; Underwood, J H; Gullikson, E M; Bajt, S; Folta, J A; Kearney, P A; Montcalm, C; Spiller, E

    1999-12-29

    Synchrotron-based reflectometry is an important technique for the precise determination of optical properties of reflective multilayer coatings for Extreme Ultraviolet Lithography (EUVL). Multilayer coatings enable normal incidence reflectances of more than 65% in the wavelength range between 11 and 15 nm. In order to achieve high resolution and throughput of EUVL systems, stringent requirements not only apply to their mechanical and optical layout, but also apply to the optical properties of the multilayer coatings. Therefore, multilayer deposition on near-normal incidence optical surfaces of projection optics, condenser optics and reflective masks requires suitable high-precision metrology. Most important, due to their small bandpass on the order of only 0.5 nm, all reflective multilayer coatings in EUVL systems must be wavelength-matched to within {+-}0.05 nm. In some cases, a gradient of the coating thickness is necessary for wavelength matching at variable average angle of incidence in different locations on the optical surfaces. Furthermore, in order to preserve the geometrical figure of the optical substrates, reflective multilayer coatings need to be uniform to within 0.01 nm in their center wavelength. This requirement can only be fulfilled with suitable metrology, which provides a precision of a fraction of this value. In addition, for the detailed understanding and the further development of reflective multilayer coatings a precision in the determination of peak reflectances is desirable on the order of 0.1%. Substrates up to 200 mm in diameter and 15 kg in mass need to be accommodated. Above requirements are fulfilled at beamline 6.3.2 of the Advanced Light Source (ALS) in Berkeley. This beamline proved to be precise within 0.2% (ms) for reflectance and 0.002 nm (rms) for wavelength.

  7. High-Precision Superallowed Fermi β Decay Measurements at TRIUMF-ISAC

    NASA Astrophysics Data System (ADS)

    Svensson, C. E.

    2016-09-01

    High-precision measurements of the ft -values for superallowed Fermi β decays between nuclear isobaric analogue states provide demanding tests of the electroweak Standard Model, including confirmation of the Conserved Vector Current hypothesis at the level of 1 . 2 ×10-4 , the most stringent limits on weak scalar currents, and the most precise determination of the Vud element of the CKM quark-mixing matrix. The Isotope Separator and Accelerator (ISAC) facility at TRIUMF produces high-quality beams of several of the superallowed emitters with world-record intensities and hosts a suite of state-of-the-art spectrometers for the measurement of superallowed half-lives, branching ratios, QEC values, and charge-radii. Recent highlights from the superallowed program at ISAC, including high-precision half-life measurements for the light superallowed emitters 10C, 14O, 18Ne, and 26mAl and branching-ratio measurements for the heavy superallowed emitters 62Ga and 74Rb will be presented. The impact of these measurements on tests of the Standard Model, and future developments in the superallowed program at ISAC with the new high-efficiency GRIFFIN γ - ray spectrometer, will be discussed. Research supported by the Natural Sciences and Engineering Research Council of Canada, the Canada Foundation for Innovation, and the Canada Research Chairs Program. TRIUMF receives federal funding via the National Research Council of Canada.

  8. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage.

    PubMed

    Yang, Z; Chen, H; Yu, T; Li, B

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  9. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

    NASA Astrophysics Data System (ADS)

    Yang, Z.; Chen, H.; Yu, T.; Li, B.

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  10. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

    SciTech Connect

    Yang, Z. Yu, T.; Chen, H.; Li, B.

    2016-08-15

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  11. Direct high-precision measurement of the magnetic moment of the proton.

    PubMed

    Mooser, A; Ulmer, S; Blaum, K; Franke, K; Kracke, H; Leiteritz, C; Quint, W; Rodegheri, C C; Smorra, C; Walz, J

    2014-05-29

    One of the fundamental properties of the proton is its magnetic moment, µp. So far µp has been measured only indirectly, by analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in terms of the nuclear magneton: μp = 2.792847350(9)μN. This measurement outperforms previous Penning-trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty-year-old indirect measurement, in which significant theoretical bound state corrections were required to obtain µp, by a factor of 3. By application of this method to the antiproton magnetic moment, the fractional precision of the recently reported value can be improved by a factor of at least 1,000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.

  12. High Precision Calculations of the Lennard-Jones Lattice Constants for Five Lattices

    NASA Astrophysics Data System (ADS)

    Stein, Matthew

    2017-01-01

    The total potential energy of a crystal as described by the Lennard-Jones (L-J) potential depends in part upon the calculation of lattice constants. Knowing these constants to high precision is useful for prediction of the lattice type and simulation of crystals such as rare-gas solids or germanium detectors, but reaching higher precision is computationally costly and challenging. Presented here is the extension of the precision of the lattice constants, Lp, up to 32 decimal digits, and in some cases corrections from previous publication. The Lp terms are given for 4 <= p <= 30 in the simple cubic, face-centered cubic, body-centered cubic, hexagonal-close-pack, and diamond lattices. This precision was obtained through the use of careful parallelization technique, exploitation of the symmetries of each lattice, and the ``onionization'' of the simulated crystal. The results of this computation, along with the tools and algorithm strategies to make this computation possible, are explained in detail graphically.

  13. Direct high-precision measurement of the magnetic moment of the proton

    NASA Astrophysics Data System (ADS)

    Mooser, A.; Ulmer, S.; Blaum, K.; Franke, K.; Kracke, H.; Leiteritz, C.; Quint, W.; Rodegheri, C. C.; Smorra, C.; Walz, J.

    2014-05-01

    One of the fundamental properties of the proton is its magnetic moment, µp. So far µp has been measured only indirectly, by analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in terms of the nuclear magneton: μp = 2.792847350(9)μN. This measurement outperforms previous Penning-trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty-year-old indirect measurement, in which significant theoretical bound state corrections were required to obtain µp, by a factor of 3. By application of this method to the antiproton magnetic moment, the fractional precision of the recently reported value can be improved by a factor of at least 1,000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.

  14. Use of an automated chromium reduction system for hydrogen isotope ratio analysis of physiological fluids applied to doubly labeled water analysis.

    PubMed

    Schoeller, D A; Colligan, A S; Shriver, T; Avak, H; Bartok-Olson, C

    2000-09-01

    The doubly labeled water method is commonly used to measure total energy expenditure in free-living subjects. The method, however, requires accurate and precise deuterium abundance determinations, which can be laborious. The aim of this study was to evaluate a fully automated, high-throughput, chromium reduction technique for the measurement of deuterium abundances in physiological fluids. The chromium technique was compared with an off-line zinc bomb reduction technique and also subjected to test-retest analysis. Analysis of international water standards demonstrated that the chromium technique was accurate and had a within-day precision of <1 per thousand. Addition of organic matter to water samples demonstrated that the technique was sensitive to interference at levels between 2 and 5 g l(-1). Physiological samples could be analyzed without this interference, plasma by 10000 Da exclusion filtration, saliva by sedimentation and urine by decolorizing with carbon black. Chromium reduction of urine specimens from doubly labeled water studies indicated no bias relative to zinc reduction with a mean difference in calculated energy expenditure of -0.2 +/- 3.9%. Blinded reanalysis of urine specimens from a second doubly labeled water study demonstrated a test-retest coefficient of variation of 4%. The chromium reduction method was found to be a rapid, accurate and precise method for the analysis of urine specimens from doubly labeled water. Copyright 2000 John Wiley & Sons, Ltd.

  15. High-precision image aided inertial navigation with known features: observability analysis and performance evaluation.

    PubMed

    Jiang, Weiping; Wang, Li; Niu, Xiaoji; Zhang, Quan; Zhang, Hui; Tang, Min; Hu, Xiangyun

    2014-10-17

    A high-precision image-aided inertial navigation system (INS) is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs) when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF). Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three) are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level) and attitude (half-degree-level)-integrated solutions can be achieved in a global reference.

  16. High-Precision Image Aided Inertial Navigation with Known Features: Observability Analysis and Performance Evaluation

    PubMed Central

    Jiang, Weiping; Wang, Li; Niu, Xiaoji; Zhang, Quan; Zhang, Hui; Tang, Min; Hu, Xiangyun

    2014-01-01

    A high-precision image-aided inertial navigation system (INS) is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs) when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF). Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three) are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level) and attitude (half-degree-level)-integrated solutions can be achieved in a global reference. PMID:25330046

  17. Determination of the half-life of 213Fr with high precision

    NASA Astrophysics Data System (ADS)

    Fisichella, M.; Musumarra, A.; Farinon, F.; Nociforo, C.; Del Zoppo, A.; Figuera, P.; La Cognata, M.; Pellegriti, M. G.; Scuderi, V.; Torresi, D.; Strano, E.

    2013-07-01

    High-precision measurement of half-life and Qα value of neutral and highly charged α emitters is a major subject of investigation currently. In this framework, we recently pushed half-life measurements of neutral emitters to a precision of a few per mil. This result was achieved by using different techniques and apparatuses at Istituto Nazionale di Fisica Nucleare Laboratori Nazionali del Sud (INFN-LNS) and GSI Darmstadt. Here we report on 213Fr half-life determination [T1/2(213Fr) = 34.14±0.06 s] at INFN-LNS, detailing the measurement protocol used. Direct comparison with the accepted value in the literature shows a discrepancy of more than three sigma. We propose this new value as a reference, discussing previous experiments.

  18. Geometrical aspects of laser-drilled high precision holes for flow control applications

    NASA Astrophysics Data System (ADS)

    Giedl, Roswitha; Helml, H.-J.; Wagner, F. X.; Wild, Michael J.

    2003-11-01

    Laser drilling has become a valuable tool for the manufacture of high precision micro holes in a variety of materials. Laser drilled precision holes have applications in the automotive, aerospace, medical and sensor industry for flow control applications. The technology is competing with conventional machining micro electro-discharge machining in the field of fuel injection nozzle for combustion engines. Depending on the application, laser and optics have to be chosen which suits the requirements. In this paper, the results achieved with different lasers and drilling techniques will be compared to the hole specifications in flow control applications. The issue of geometry control of high aspect ratio laser drilled holes in metals will be investigated. The comparison of flow measurement results to microscopic hole dimension measurement show that flow characteristics strongly depend on cavitation number during flow.

  19. Optical timing receiver for the NASA laser ranging system. Part 2: High precision time interval digitizer

    NASA Technical Reports Server (NTRS)

    Leskovar, B.; Turko, B.

    1977-01-01

    The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.

  20. On the Mitigation of Solar Index Variability for High Precision Orbit Determination in Low Earth Orbit

    DTIC Science & Technology

    2016-09-16

    and ANal- ysis ( OCEAN ) tool to evaluate solution accuracy and predictive capabilities of each combination. In all test cases examined, using either the...Orbit Covariance Estimation and ANalysis ( OCEAN ) high precision orbit deter- mination tool in order to determine the suitability of each model for...the National Oceanic and Atmospheric Administration (NOAA) Space Weather Prediction Center (SWPC). There is an extensive body of work studying the