ERIC Educational Resources Information Center
Gonzales, Stacey
2013-01-01
This quantitative study explored the relationships among high-school teachers' (n = 74) technology self-efficacy, teachers' attitudes towards technology integration, and quality of teachers' technology integration into instruction. This study offered the unique perspectives of in-service high-school teachers as they have first-hand experience…
Highly Integrated Quality Assurance – An Empirical Case
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drake Kirkham; Amy Powell; Lucas Rich
2011-02-01
Highly Integrated Quality Assurance – An Empirical Case Drake Kirkham1, Amy Powell2, Lucas Rich3 1Quality Manager, Radioisotope Power Systems (RPS) Program, Idaho National Laboratory, P.O. Box 1625 M/S 6122, Idaho Falls, ID 83415-6122 2Quality Engineer, RPS Program, Idaho National Laboratory 3Quality Engineer, RPS Program, Idaho National Laboratory Contact: Voice: (208) 533-7550 Email: Drake.Kirkham@inl.gov Abstract. The Radioisotope Power Systems Program of the Idaho National Laboratory makes an empirical case for a highly integrated Quality Assurance function pertaining to the preparation, assembly, testing, storage and transportation of 238Pu fueled radioisotope thermoelectric generators. Case data represents multiple campaigns including the Pluto/New Horizons mission,more » the Mars Science Laboratory mission in progress, and other related projects. Traditional Quality Assurance models would attempt to reduce cost by minimizing the role of dedicated Quality Assurance personnel in favor of either functional tasking or peer-based implementations. Highly integrated Quality Assurance adds value by placing trained quality inspectors on the production floor side-by-side with nuclear facility operators to enhance team dynamics, reduce inspection wait time, and provide for immediate, independent feedback. Value is also added by maintaining dedicated Quality Engineers to provide for rapid identification and resolution of corrective action, enhanced and expedited supply chain interfaces, improved bonded storage capabilities, and technical resources for requirements management including data package development and Certificates of Inspection. A broad examination of cost-benefit indicates highly integrated Quality Assurance can reduce cost through the mitigation of risk and reducing administrative burden thereby allowing engineers to be engineers, nuclear operators to be nuclear operators, and the cross-functional team to operate more efficiently. Applicability of this case extends to any high-value, long-term project where traceability and accountability are determining factors.« less
LEC GaAs for integrated circuit applications
NASA Technical Reports Server (NTRS)
Kirkpatrick, C. G.; Chen, R. T.; Homes, D. E.; Asbeck, P. M.; Elliott, K. R.; Fairman, R. D.; Oliver, J. D.
1984-01-01
Recent developments in liquid encapsulated Czochralski techniques for the growth of semiinsulating GaAs for integrated circuit applications have resulted in significant improvements in the quality and quantity of GaAs material suitable for device processing. The emergence of high performance GaAs integrated circuit technologies has accelerated the demand for high quality, large diameter semiinsulating GaAs substrates. The new device technologies, including digital integrated circuits, monolithic microwave integrated circuits and charge coupled devices have largely adopted direct ion implantation for the formation of doped layers. Ion implantation lends itself to good uniformity and reproducibility, high yield and low cost; however, this technique also places stringent demands on the quality of the semiinsulating GaAs substrates. Although significant progress was made in developing a viable planar ion implantation technology, the variability and poor quality of GaAs substrates have hindered progress in process development.
Best Practices: Power Quality and Integrated Testing at JSC
NASA Technical Reports Server (NTRS)
Davis, Lydia
2018-01-01
This presentation discusses Best Practices for Power Quality and Integrated Testing at JSC in regards to electrical systems. These high-level charts include mostly generic information; however, a specific issue is discussed involving flight hardware that could have been discovered prior to flight with an integrated test.
Zhang, Chenchu; Hu, Yanlei; Du, Wenqiang; Wu, Peichao; Rao, Shenglong; Cai, Ze; Lao, Zhaoxin; Xu, Bing; Ni, Jincheng; Li, Jiawen; Zhao, Gang; Wu, Dong; Chu, Jiaru; Sugioka, Koji
2016-09-13
Rapid integration of high-quality functional devices in microchannels is in highly demand for miniature lab-on-a-chip applications. This paper demonstrates the embellishment of existing microfluidic devices with integrated micropatterns via femtosecond laser MRAF-based holographic patterning (MHP) microfabrication, which proves two-photon polymerization (TPP) based on spatial light modulator (SLM) to be a rapid and powerful technology for chip functionalization. Optimized mixed region amplitude freedom (MRAF) algorithm has been used to generate high-quality shaped focus field. Base on the optimized parameters, a single-exposure approach is developed to fabricate 200 × 200 μm microstructure arrays in less than 240 ms. Moreover, microtraps, QR code and letters are integrated into a microdevice by the advanced method for particles capture and device identification. These results indicate that such a holographic laser embellishment of microfluidic devices is simple, flexible and easy to access, which has great potential in lab-on-a-chip applications of biological culture, chemical analyses and optofluidic devices.
NASA Astrophysics Data System (ADS)
Zhang, Chenchu; Hu, Yanlei; Du, Wenqiang; Wu, Peichao; Rao, Shenglong; Cai, Ze; Lao, Zhaoxin; Xu, Bing; Ni, Jincheng; Li, Jiawen; Zhao, Gang; Wu, Dong; Chu, Jiaru; Sugioka, Koji
2016-09-01
Rapid integration of high-quality functional devices in microchannels is in highly demand for miniature lab-on-a-chip applications. This paper demonstrates the embellishment of existing microfluidic devices with integrated micropatterns via femtosecond laser MRAF-based holographic patterning (MHP) microfabrication, which proves two-photon polymerization (TPP) based on spatial light modulator (SLM) to be a rapid and powerful technology for chip functionalization. Optimized mixed region amplitude freedom (MRAF) algorithm has been used to generate high-quality shaped focus field. Base on the optimized parameters, a single-exposure approach is developed to fabricate 200 × 200 μm microstructure arrays in less than 240 ms. Moreover, microtraps, QR code and letters are integrated into a microdevice by the advanced method for particles capture and device identification. These results indicate that such a holographic laser embellishment of microfluidic devices is simple, flexible and easy to access, which has great potential in lab-on-a-chip applications of biological culture, chemical analyses and optofluidic devices.
Dickerson, Pam; Chappell, Kathy
2015-01-01
One of the hallmarks of quality continuing education developed using accreditation criteria is content integrity. Components of content integrity include identifying, resolving, and disclosing conflict of interest; ensuring content is based on the best available evidence; managing commercial support (if applicable); and presenting the educational activity free of promotion or bias. This article explores content integrity, conflict of interest, and commercial support. Understanding and being able to operationalize these concepts will enable providers to offer high-quality educational activities that promote the professional development of nurses and/or improve the quality of patient care.
[Informatics data quality and management].
Feng, Rung-Chuang
2009-06-01
While the quality of data affects every aspect of business, it is frequently overlooked in terms of customer data integration, data warehousing, business intelligence and enterprise applications. Regardless of which data terms are used, a high level of data quality is a critical base condition essential to satisfy user needs and facilitate the development of effective applications. In this paper, the author introduces methods, a management framework and the major factors involved in data quality assessment. Author also integrates expert opinions to develop data quality assessment tools.
Integration of immigrants into a new culture is related to poor sleep quality.
Voss, Ursula; Tuin, Inka
2008-08-10
This article reports on the relationship between cultural influences on life style, coping style, and sleep in a sample of female Portuguese immigrants living in Germany. Sleep quality is known to be poorer in women than in men, yet little is known about mediating psychological and sociological variables such as stress and coping with stressful life circumstances. Migration constitutes a particularly difficult life circumstance for women if it involves differing role conceptions in the country of origin and the emigrant country. The study investigated sleep quality, coping styles and level of integration in a sample of Portuguese (N = 48) and Moroccan (N = 64) immigrant women who took part in a structured personal interview. Sleep quality was poor in 54% of Portuguese and 39% of Moroccan women, which strongly exceeds reports of sleep complaints in epidemiologic studies of sleep quality in German women. Reports of poor sleep were associated with the degree of adoption of a German life style. Women who had integrated more into German society slept worse than less integrated women in both samples, suggesting that non-integration serves a protective function. An unusually large proportion of women preferred an information-seeking (monitoring) coping style and adaptive coping. Poor sleep was related to high monitoring in the Portuguese but not the Moroccan sample. Sleep quality appears to be severely affected in women with a migration background. Our data suggest that non-integration may be less stressful than integration. This result points to possible benefits of non-integration. The high preference for an information-seeking coping style may be related to the process of migration, representing the attempt at regaining control over an uncontrollable and stressful life situation.
Integration of immigrants into a new culture is related to poor sleep quality
Voss, Ursula; Tuin, Inka
2008-01-01
Background This article reports on the relationship between cultural influences on life style, coping style, and sleep in a sample of female Portuguese immigrants living in Germany. Sleep quality is known to be poorer in women than in men, yet little is known about mediating psychological and sociological variables such as stress and coping with stressful life circumstances. Migration constitutes a particularly difficult life circumstance for women if it involves differing role conceptions in the country of origin and the emigrant country. Methods The study investigated sleep quality, coping styles and level of integration in a sample of Portuguese (N = 48) and Moroccan (N = 64) immigrant women who took part in a structured personal interview. Results Sleep quality was poor in 54% of Portuguese and 39% of Moroccan women, which strongly exceeds reports of sleep complaints in epidemiologic studies of sleep quality in German women. Reports of poor sleep were associated with the degree of adoption of a German life style. Women who had integrated more into German society slept worse than less integrated women in both samples, suggesting that non-integration serves a protective function. An unusually large proportion of women preferred an information-seeking (monitoring) coping style and adaptive coping. Poor sleep was related to high monitoring in the Portuguese but not the Moroccan sample. Conclusion Sleep quality appears to be severely affected in women with a migration background. Our data suggest that non-integration may be less stressful than integration. This result points to possible benefits of non-integration. The high preference for an information-seeking coping style may be related to the process of migration, representing the attempt at regaining control over an uncontrollable and stressful life situation. PMID:18691437
Zhang, Chenchu; Hu, Yanlei; Du, Wenqiang; Wu, Peichao; Rao, Shenglong; Cai, Ze; Lao, Zhaoxin; Xu, Bing; Ni, Jincheng; Li, Jiawen; Zhao, Gang; Wu, Dong; Chu, Jiaru; Sugioka, Koji
2016-01-01
Rapid integration of high-quality functional devices in microchannels is in highly demand for miniature lab-on-a-chip applications. This paper demonstrates the embellishment of existing microfluidic devices with integrated micropatterns via femtosecond laser MRAF-based holographic patterning (MHP) microfabrication, which proves two-photon polymerization (TPP) based on spatial light modulator (SLM) to be a rapid and powerful technology for chip functionalization. Optimized mixed region amplitude freedom (MRAF) algorithm has been used to generate high-quality shaped focus field. Base on the optimized parameters, a single-exposure approach is developed to fabricate 200 × 200 μm microstructure arrays in less than 240 ms. Moreover, microtraps, QR code and letters are integrated into a microdevice by the advanced method for particles capture and device identification. These results indicate that such a holographic laser embellishment of microfluidic devices is simple, flexible and easy to access, which has great potential in lab-on-a-chip applications of biological culture, chemical analyses and optofluidic devices. PMID:27619690
Ryu, Jeong-Im; Kim, Kisook
2018-06-20
To investigate differences in work satisfaction and quality of nursing services between nurses from the nursing care integration service and general nursing units in Korea. The nursing care integration service was recently introduced in Korea to improve patient health outcomes through the provision of high quality nursing services and to relieve the caregiving burden of patients' families. In this cross-sectional study, data were collected from a convenience sample of 116 and 156 nurses working in nursing care integration service and general units, respectively. The data were analysed using descriptive statistics, t tests and one-way analysis of variance. Regarding work satisfaction, nursing care integration service nurses scored higher than general unit nurses on professional status, autonomy and task requirements, but the overall scores showed no significant differences. Scores on overall quality of nursing services, responsiveness and assurance were higher for nursing care integration service nurses than for general unit nurses. Nursing care integration service nurses scored higher than general unit nurses on some aspects of work satisfaction and quality of nursing services. Further studies with larger sample sizes will contribute to improving the quality of nursing care integration service units. These findings can help to establish strategies for the implementation and efficient operation of the nursing care integration service system, for the improvement of the quality of nursing services, and for successfully implementing and expanding nursing care integration service services in other countries. © 2018 John Wiley & Sons Ltd.
Constraint-Driven Software Design: An Escape from the Waterfall Model.
ERIC Educational Resources Information Center
de Hoog, Robert; And Others
1994-01-01
Presents the principles of a development methodology for software design based on a nonlinear, product-driven approach that integrates quality aspects. Two examples are given to show that the flexibility needed for building high quality systems leads to integrated development environments in which methodology, product, and tools are closely…
Design and realization of high quality prime farmland planning and management information system
NASA Astrophysics Data System (ADS)
Li, Manchun; Liu, Guohong; Liu, Yongxue; Jiang, Zhixin
2007-06-01
The article discusses the design and realization of a high quality prime farmland planning and management information system based on SDSS. Models in concept integration, management planning are used in High Quality Prime Farmland Planning in order to refine the current model system and the management information system is deigned with a triangular structure. Finally an example of Tonglu county high quality prime farmland planning and management information system is introduced.
Song, Jiangxin; Lin, Jintian; Tang, Jialei; Liao, Yang; He, Fei; Wang, Zhaohui; Qiao, Lingling; Sugioka, Koji; Cheng, Ya
2014-06-16
We report on fabrication of a microtoroid resonator of a high-quality factor (i.e., Q-factor of ~3.24 × 10(6) measured under the critical coupling condition) integrated in a microfluidic channel using femtosecond laser three-dimensional (3D) micromachining. Coupling of light into and out of the microresonator has been realized with a fiber taper that is reliably assembled with the microtoroid. The assembly of the fiber to the microtoroid is achieved by welding the fiber taper onto the sidewall of the microtoroid using CO2 laser irradiation. The integrated microresonator maintains a high Q-factor of 3.21 × 10(5) as measured in air, which should still be sufficient for many sensing applications. We test the functionality of the integrated optofluidic sensor by performing bulk refractive index sensing of purified water doped with tiny amount of salt. It is shown that a detection limit of ~1.2 × 10(-4) refractive index unit can be achieved. Our result showcases the capability of integration of high-Q microresonators with complex microfluidic systems using femtosecond laser 3D micromachining.
NASA Astrophysics Data System (ADS)
Hufenbach, W.; Gude, M.; Czulak, A.; Kretschmann, Martin
2014-04-01
Increasing economic, political and ecological pressure leads to steadily rising percentage of modern processing and manufacturing processes for fibre reinforced polymers in industrial batch production. Component weights beneath a level achievable by classic construction materials, which lead to a reduced energy and cost balance during product lifetime, justify the higher fabrication costs. However, complex quality control and failure prediction slow down the substitution by composite materials. High-resolution fibre-optic sensors (FOS), due their low diameter, high measuring point density and simple handling, show a high applicability potential for an automated sensor-integration in manufacturing processes, and therefore the online monitoring of composite products manufactured in industrial scale. Integrated sensors can be used to monitor manufacturing processes, part tests as well as the component structure during product life cycle, which simplifies allows quality control during production and the optimization of single manufacturing processes.[1;2] Furthermore, detailed failure analyses lead to a enhanced understanding of failure processes appearing in composite materials. This leads to a lower wastrel number and products of a higher value and longer product life cycle, whereby costs, material and energy are saved. This work shows an automation approach for FOS-integration in the braiding process. For that purpose a braiding wheel has been supplemented with an appliance for automatic sensor application, which has been used to manufacture preforms of high-pressure composite vessels with FOS-networks integrated between the fibre layers. All following manufacturing processes (vacuum infiltration, curing) and component tests (quasi-static pressure test, programmed delamination) were monitored with the help of the integrated sensor networks. Keywords: SHM, high-pressure composite vessel, braiding, automated sensor integration, pressure test, quality control, optic-fibre sensors, Rayleigh, Luna Technologies
High-quality digital color xerography
NASA Astrophysics Data System (ADS)
Takiguchi, Koichi
1993-06-01
Image noise, tone reproduction, color reproduction, fine line reproduction, and OHP performance are the most important characteristics for a high quality color copier. Technologies enabling such quality are use of fine toner, halftone algorithm to ensure good highlight reproduction, soft roll fuser with good release performance, smooth surface and high thermal conductivity, white and smooth paper, and selection of a coating material for the surface layer of the OHP sheets. These technologies are integrated in the Fuji Xerox `A- Color' product. Utilizing 7 micrometers color toner, `A-Color' can make very high quality color copies.
NASA Astrophysics Data System (ADS)
Jing, Xiaoli; Cheng, Haobo; Wen, Yongfu
2018-04-01
A new local integration algorithm called quality map path integration (QMPI) is reported for shape reconstruction in the fringe reflection technique. A quality map is proposed to evaluate the quality of gradient data locally, and functions as a guideline for the integrated path. The presented method can be employed in wavefront estimation from its slopes over the general shaped surface with slope noise equivalent to that in practical measurements. Moreover, QMPI is much better at handling the slope data with local noise, which may be caused by the irregular shapes of the surface under test. The performance of QMPI is discussed by simulations and experiment. It is shown that QMPI not only improves the accuracy of local integration, but can also be easily implemented with no iteration compared to Southwell zonal reconstruction (SZR). From an engineering point-of-view, the proposed method may also provide an efficient and stable approach for different shapes with high-precise demand.
Sun, Qiang; Yin, Jia; Yin, Xiao; Zou, Guanyang; Liang, Mingli; Zhong, Jieming; Walley, John; Wei, Xiaolin
2013-06-01
Moving the clinical services from tuberculosis (TB) dispensary to the integrated county hospital (called integrated approach) has been practiced in China; however, it is unknown the quality of TB care in the integrated approach and in the dispensary approach. A total of 202 new TB patients were investigated using structured questionnaires in three counties implementing the integrated approach and one county implementing the dispensary approach. The quality of TB care is measured based on success rate of treatment, medical expenditure, health system delay and second-line drug use. The integrated approach showed a high success treatment rate. The medical expenditure in the integrated approach was USD 432, significantly lower than that in the dispensary approach (Z = -5.771, P < 0.001). The integrated approach had a shorter health system delay (5 days) than the dispensary approach (32 days). Twenty-six percent of patients in integrated hospitals were prescribed with second-line TB drugs, significantly lower than that in the TB dispensary (47%, χ(2) = 7.452, P = 0.006). However, the medical expenditure, use of second-line anti-TB drug and liver-protection drugs indeed varied greatly across the three integrated hospitals. The integrated approach showed better quality of TB care, but the performance of the integrated hospitals varied greatly. A method to standardize TB treatment and management of this approach is urgent.
78 FR 53991 - Applications for New Awards; Race to the Top-Early Learning Challenge
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
... gaps for Children with High Needs.\\1\\ This program focuses on improving early learning and development... disadvantaged children in each age group of infants, toddlers, and preschoolers who are enrolled in high-quality... implement an integrated system of high-quality Early Learning and Development Programs and services. \\1...
High-Performance Integrated Control of water quality and quantity in urban water reservoirs
NASA Astrophysics Data System (ADS)
Galelli, S.; Castelletti, A.; Goedbloed, A.
2015-11-01
This paper contributes a novel High-Performance Integrated Control framework to support the real-time operation of urban water supply storages affected by water quality problems. We use a 3-D, high-fidelity simulation model to predict the main water quality dynamics and inform a real-time controller based on Model Predictive Control. The integration of the simulation model into the control scheme is performed by a model reduction process that identifies a low-order, dynamic emulator running 4 orders of magnitude faster. The model reduction, which relies on a semiautomatic procedural approach integrating time series clustering and variable selection algorithms, generates a compact and physically meaningful emulator that can be coupled with the controller. The framework is used to design the hourly operation of Marina Reservoir, a 3.2 Mm3 storm-water-fed reservoir located in the center of Singapore, operated for drinking water supply and flood control. Because of its recent formation from a former estuary, the reservoir suffers from high salinity levels, whose behavior is modeled with Delft3D-FLOW. Results show that our control framework reduces the minimum salinity levels by nearly 40% and cuts the average annual deficit of drinking water supply by about 2 times the active storage of the reservoir (about 4% of the total annual demand).
CMOS compatible fabrication process of MEMS resonator for timing reference and sensing application
NASA Astrophysics Data System (ADS)
Huynh, Duc H.; Nguyen, Phuong D.; Nguyen, Thanh C.; Skafidas, Stan; Evans, Robin
2015-12-01
Frequency reference and timing control devices are ubiquitous in electronic applications. There is at least one resonator required for each of this device. Currently electromechanical resonators such as crystal resonator, ceramic resonator are the ultimate choices. This tendency will probably keep going for many more years. However, current market demands for small size, low power consumption, cheap and reliable products, has divulged many limitations of this type of resonators. They cannot be integrated into standard CMOS (Complement metaloxide- semiconductor) IC (Integrated Circuit) due to material and fabrication process incompatibility. Currently, these devices are off-chip and they require external circuitries to interface with the ICs. This configuration significantly increases the overall size and cost of the entire electronic system. In addition, extra external connection, especially at high frequency, will potentially create negative impacts on the performance of the entire system due to signal degradation and parasitic effects. Furthermore, due to off-chip packaging nature, these devices are quite expensive, particularly for high frequency and high quality factor devices. To address these issues, researchers have been intensively studying on an alternative for type of resonator by utilizing the new emerging MEMS (Micro-electro-mechanical systems) technology. Recent progress in this field has demonstrated a MEMS resonator with resonant frequency of 2.97 GHz and quality factor (measured in vacuum) of 42900. Despite this great achievement, this prototype is still far from being fully integrated into CMOS system due to incompatibility in fabrication process and its high series motional impedance. On the other hand, fully integrated MEMS resonator had been demonstrated but at lower frequency and quality factor. We propose a design and fabrication process for a low cost, high frequency and a high quality MEMS resonator, which can be integrated into a standard CMOS IC. This device is expected to operate in hundreds of Mhz frequency range; quality factor surpasses 10000 and series motional impedance low enough that could be matching into conventional system without enormous effort. This MEMS resonator can be used in the design of many blocks in wireless and RF (Radio Frequency) systems such as low phase noise oscillator, band pass filter, power amplifier and in many sensing application.
NASA Technical Reports Server (NTRS)
Kondoz, A. M.; Evans, B. G.
1993-01-01
In the last decade, low bit rate speech coding research has received much attention resulting in newly developed, good quality, speech coders operating at as low as 4.8 Kb/s. Although speech quality at around 8 Kb/s is acceptable for a wide variety of applications, at 4.8 Kb/s more improvements in quality are necessary to make it acceptable to the majority of applications and users. In addition to the required low bit rate with acceptable speech quality, other facilities such as integrated digital echo cancellation and voice activity detection are now becoming necessary to provide a cost effective and compact solution. In this paper we describe a CELP speech coder with integrated echo canceller and a voice activity detector all of which have been implemented on a single DSP32C with 32 KBytes of SRAM. The quality of CELP coded speech has been improved significantly by a new codebook implementation which also simplifies the encoder/decoder complexity making room for the integration of a 64-tap echo canceller together with a voice activity detector.
Hu, E; Liao, T. W.; Tiersch, T. R.
2013-01-01
Cryopreservation of fish sperm has been studied for decades at a laboratory (research) scale. However, high-throughput cryopreservation of fish sperm has recently been developed to enable industrial-scale production. This study treated blue catfish (Ictalurus furcatus) sperm high-throughput cryopreservation as a manufacturing production line and initiated quality assurance plan development. The main objectives were to identify: 1) the main production quality characteristics; 2) the process features for quality assurance; 3) the internal quality characteristics and their specification designs; 4) the quality control and process capability evaluation methods, and 5) the directions for further improvements and applications. The essential product quality characteristics were identified as fertility-related characteristics. Specification design which established the tolerance levels according to demand and process constraints was performed based on these quality characteristics. Meanwhile, to ensure integrity throughout the process, internal quality characteristics (characteristics at each quality control point within process) that could affect fertility-related quality characteristics were defined with specifications. Due to the process feature of 100% inspection (quality inspection of every fish), a specific calculation method, use of cumulative sum (CUSUM) control charts, was applied to monitor each quality characteristic. An index of overall process evaluation, process capacity, was analyzed based on in-control process and the designed specifications, which further integrates the quality assurance plan. With the established quality assurance plan, the process could operate stably and quality of products would be reliable. PMID:23872356
IMPACTS OF NITROGEN LOADING ON SALT MARSH INTEGRITY IN NEW ENGLAND, USA
Salt marsh habitat integrity is linked with the ability to provide good water quality and high biodiversity. We measured high denitrification enzyme activity (DEA) in ten coastal salt marshes in Narragansett Bay, Rhode Island (seasonal means ranging from 7,476 - 53,494 kg N-1ha-...
Pérez-Portela, Rocío; Riesgo, Ana
2013-09-01
Transcriptomic information provides fundamental insights into biological processes. Extraction of quality RNA is a challenging step, and preservation and extraction protocols need to be adjusted in many cases. Our objectives were to optimize preservation protocols for isolation of high-quality RNA from diverse echinoderm tissues and to compare the utility of parameters as absorbance ratios and RIN values to assess RNA quality. Three different tissues (gonad, oesophagus and coelomocytes) were selected from the sea urchin Arbacia lixula. Solid tissues were flash-frozen and stored at -80 °C until processed. Four preservation treatments were applied to coelomocytes: flash freezing and storage at -80 °C, RNAlater and storage at -20 °C, preservation in TRIzol reagent and storage at -80 °C and direct extraction with TRIzol from fresh cells. Extractions of total RNA were performed with a modified TRIzol protocol for all tissues. Our results showed high values of RNA quantity and quality for all tissues, showing nonsignificant differences among them. However, while flash freezing was effective for solid tissues, it was inadequate for coelomocytes because of the low quality of the RNA extractions. Coelomocytes preserved in RNAlater displayed large variability in RNA integrity and insufficient RNA amount for further isolation of mRNA. TRIzol was the most efficient system for stabilizing RNA which resulted on high RNA quality and quantity. We did not detect correlation between absorbance ratios and RNA integrity. The best strategies for assessing RNA integrity was the visualization of 18S rRNA and 28S rRNA bands in agarose gels and estimation of RIN values with Agilent Bioanalyzer chips. © 2013 John Wiley & Sons Ltd.
Hudait, Mantu K.; Clavel, Michael; Goley, Patrick; Jain, Nikhil; Zhu, Yan
2014-01-01
Germanium-based materials and device architectures have recently appeared as exciting material systems for future low-power nanoscale transistors and photonic devices. Heterogeneous integration of germanium (Ge)-based materials on silicon (Si) using large bandgap buffer architectures could enable the monolithic integration of electronics and photonics. In this paper, we report on the heterogeneous integration of device-quality epitaxial Ge on Si using composite AlAs/GaAs large bandgap buffer, grown by molecular beam epitaxy that is suitable for fabricating low-power fin field-effect transistors required for continuing transistor miniaturization. The superior structural quality of the integrated Ge on Si using AlAs/GaAs was demonstrated using high-resolution x-ray diffraction analysis. High-resolution transmission electron microscopy confirmed relaxed Ge with high crystalline quality and a sharp Ge/AlAs heterointerface. X-ray photoelectron spectroscopy demonstrated a large valence band offset at the Ge/AlAs interface, as compared to Ge/GaAs heterostructure, which is a prerequisite for superior carrier confinement. The temperature-dependent electrical transport properties of the n-type Ge layer demonstrated a Hall mobility of 370 cm2/Vs at 290 K and 457 cm2/Vs at 90 K, which suggests epitaxial Ge grown on Si using an AlAs/GaAs buffer architecture would be a promising candidate for next-generation high-performance and energy-efficient fin field-effect transistor applications. PMID:25376723
Maettner, R; Sterzik, K; Isachenko, V; Strehler, E; Rahimi, G; Alabart, J L; Sánchez, R; Mallmann, P; Isachenko, E
2014-06-01
The aim of this work is to establish the relationship between the morphology of Intracytoplasmic Morphologically Selected Sperm Injection (IMSI)-selected spermatozoa and their DNA integrity. The 45 ejaculates were randomly distributed into three treatment groups: normozoospermic, oligoasthenozoospermic and oligoasthenotheratozoospermic samples. The evaluation of DNA integrity was performed using the sperm chromatin dispersion test. It was established that DNA integrity of spermatozoa is strongly dependent on ejaculate quality (P < 0.05). The count of spermatozoa with nonfragmented DNA in normozoospermic samples was high and independent from IMSI-morphological classes (Class 1 versus Class 3, respectively) (P > 0.1). With decreased ejaculate quality, the percentage of spermatozoa with nonfragmented DNA decreased significantly (P < 0.05) independent from morphological class. Nevertheless, the rate of IMSI-selected spermatozoa with fragmented DNA within of Class 1 in normozoospermic (Group 1), in oligoasthenozoospermic (Group 2) and in oligoasthenotheratozoospermic (Group 3) samples was 21.1%, 31.8% and 54.1%, respectively. In conclusion, there is a direct relationship between morphological parameters of spermatozoa and their DNA integrity. However, the IMSI technique alone is not enough for the selection of spermatozoa with intact nuclei. © 2013 Blackwell Verlag GmbH.
A comparative study of integrators for constructing ephemerides with high precision.
NASA Astrophysics Data System (ADS)
Huang, Tian-Yi
1990-09-01
There are four indexes for evaluating various integrators. They are the local truncation error, the numerical stability, the complexity of computation and the quality of adaptation. A review and a comparative study of several numerical integration methods, such as Adams, Cowell, Runge-Kutta-Fehlberg, Gragg-Bulirsch-Stoer extrapolation, Everhart, Taylor series and Krogh, which are popular for constructing ephemerides with high precision, has been worked out.
[Maintainance of a research tissue bank. (Infra)structural and quality aspects].
Schmitt, S; Kynast, K; Schirmacher, P; Herpel, E
2015-11-01
The availability of high quality human tissue samples and access to associated histopathological and clinical data are essential for biomedical research. Therefore, it is necessary to establish quality assured tissue biobanks that provide high quality tissue samples for research purposes. This entails quality concerns referring not only to the biomaterial specimen itself but encompassing all procedures related to biobanking, including the implementation of structural components, e.g. ethical and legal guidelines, quality management documentation as well as data and project management and information technology (IT) administration. Moreover, an integral aspect of tissue biobanks is the quality assured evaluation of every tissue specimen that is stored in a tissue biobank and used for projects to guarantee high quality assured biomaterial.
ERIC Educational Resources Information Center
Chen, Yixing
2013-01-01
The objective of this study was to develop a "Virtual Design Studio (VDS)": a software platform for integrated, coordinated and optimized design of green building systems with low energy consumption, high indoor environmental quality (IEQ), and high level of sustainability. The VDS is intended to assist collaborating architects,…
NASA Astrophysics Data System (ADS)
Wang, Hui-Hui
Quality STEM education is the key in helping the United States maintain its lead in global competitiveness and in preparing for new economic and security challenges in the future. Policymakers and professional societies emphasize STEM education by legislating the addition of engineering standards to the existing science standards. On the other hand, the nature of the work of most STEM professionals requires people to actively apply STEM knowledge to make critical decisions. Therefore, using an integrated approach to teaching STEM in K-12 is expected. However, science teachers encounter numerous difficulties in adapting the new STEM integration reforms into their classrooms because of a lack of knowledge and experience. Therefore, high quality STEM integration professional development programs are an urgent necessity. In order to provide these high quality programs, it is important to understand teachers' perceptions and classroom practices regarding STEM integration. A multiple-case study was conducted with five secondary school science teachers in order to gain a better understanding of teachers' perceptions and classroom practices in using STEM integration. This study addresses the following research questions: 1) What are secondary school science teachers' practices of STEM integration? 2) What are secondary science teachers' overall perceptions of STEM integration? and 3) What is the connection between secondary science teachers' perceptions and understanding of STEM integration with their classroom practices? This research aims to explore teachers' perceptions and classroom practices in order to set up the baseline for STEM integration and also to determine STEM integration professional development best practices in science education. Findings from the study provide critical data for making informed decision about the direction for STEM integration in science education in K-12.
Blick, Rachel N; Litz, Katherine S; Thornhill, Monica G; Goreczny, Anthony J
2016-01-01
More individuals with an intellectual disability now possess prerequisite skills and supports necessary for successful work force integration than did previous generations. The current study compared quality of life of community-integrated workers with those participating in sheltered vocational workshops and adult day care programs. We considered numerous indices of quality of life, including inclusion and community participation; satisfaction within professional services, home life, and day activities; dignity, rights, and respect received from others; fear; choice and control; and family satisfaction. Our data revealed several important differences in quality of life across daytime activities; participants involved in community-integrated employment tended to be younger, indicated a greater sense of community integration, and reported more financial autonomy than did those who participated in adult day care programs and sheltered workshops. However, individuals reported no differences in overall satisfaction across daytime activities. We discuss generational differences across employment status as well as possible explanations to account for high levels of satisfaction across daytime activities. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gulf of Mexico dissolved oxygen model (GoMDOM) research and quality assurance project plan
An integrated high resolution mathematical modeling framework is being developed that will link hydrodynamic, atmospheric, and water quality models for the northern Gulf of Mexico. This Research and Quality Assurance Project Plan primarily focuses on the deterministic Gulf of Me...
ERIC Educational Resources Information Center
Cunnington, Marisol; Kantrowitz, Andrea; Harnett, Susanne; Hill-Ries, Aline
2014-01-01
The "Framing Student Success: Connecting Rigorous Visual Arts, Math and Literacy Learning" experimental demonstration project was designed to develop and test an instructional program integrating high-quality, standards-based instruction in the visual arts, math, and literacy. Developed and implemented by arts-in-education organization…
The integrated design and archive of space-borne signal processing and compression coding
NASA Astrophysics Data System (ADS)
He, Qiang-min; Su, Hao-hang; Wu, Wen-bo
2017-10-01
With the increasing demand of users for the extraction of remote sensing image information, it is very urgent to significantly enhance the whole system's imaging quality and imaging ability by using the integrated design to achieve its compact structure, light quality and higher attitude maneuver ability. At this present stage, the remote sensing camera's video signal processing unit and image compression and coding unit are distributed in different devices. The volume, weight and consumption of these two units is relatively large, which unable to meet the requirements of the high mobility remote sensing camera. This paper according to the high mobility remote sensing camera's technical requirements, designs a kind of space-borne integrated signal processing and compression circuit by researching a variety of technologies, such as the high speed and high density analog-digital mixed PCB design, the embedded DSP technology and the image compression technology based on the special-purpose chips. This circuit lays a solid foundation for the research of the high mobility remote sensing camera.
Heterogeneous Monolithic Integration of Single-Crystal Organic Materials.
Park, Kyung Sun; Baek, Jangmi; Park, Yoonkyung; Lee, Lynn; Hyon, Jinho; Koo Lee, Yong-Eun; Shrestha, Nabeen K; Kang, Youngjong; Sung, Myung Mo
2017-02-01
Manufacturing high-performance organic electronic circuits requires the effective heterogeneous integration of different nanoscale organic materials with uniform morphology and high crystallinity in a desired arrangement. In particular, the development of high-performance organic electronic and optoelectronic devices relies on high-quality single crystals that show optimal intrinsic charge-transport properties and electrical performance. Moreover, the heterogeneous integration of organic materials on a single substrate in a monolithic way is highly demanded for the production of fundamental organic electronic components as well as complex integrated circuits. Many of the various methods that have been designed to pattern multiple heterogeneous organic materials on a substrate and the heterogeneous integration of organic single crystals with their crystal growth are described here. Critical issues that have been encountered in the development of high-performance organic integrated electronics are also addressed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Panigrahi, Asisa Kumar; Hemanth Kumar, C.; Bonam, Satish; Ghosh, Tamal; Rama Krishna Vanjari, Siva; Govind Singh, Shiv
2018-02-01
Enhanced Cu diffusion, Cu surface passivation, and smooth surface at the bonding interface are the key essentials for high quality Cu-Cu bonding. Previously, we have demonstrated optimized 3 nm thin Manganin metal-alloy passivation from oxidation and also helps to reduce the surface roughness to about 0.8 nm which substantially led to high quality Cu-Cu bonding. In this paper, we demonstrated an ultra fine-pitch (<25 µm) Cu-Cu bonding using an optimized Manganin metal-alloy passivation. This engineered surface passivation approach led to high quality bonding at sub 200 °C temperature and 0.4 MPa. Very low specific contact resistance of 1.4 × 10-7 Ω cm2 and the defect free bonded interface is clear indication of high quality bonding for future multilayer integrations. Furthermore, electrical characterization of the bonded structure was performed under various robust conditions as per International Technology Roadmap for Semiconductors (ITRS Roadmap) in order to satisfy the stability of the bonded structure.
Castellano, Michael J; Mueller, Kevin E; Olk, Daniel C; Sawyer, John E; Six, Johan
2015-09-01
Labile, 'high-quality', plant litters are hypothesized to promote soil organic matter (SOM) stabilization in mineral soil fractions that are physicochemically protected from rapid mineralization. However, the effect of litter quality on SOM stabilization is inconsistent. High-quality litters, characterized by high N concentrations, low C/N ratios, and low phenol/lignin concentrations, are not consistently stabilized in SOM with greater efficiency than 'low-quality' litters characterized by low N concentrations, high C/N ratios, and high phenol/lignin concentrations. Here, we attempt to resolve these inconsistent results by developing a new conceptual model that links litter quality to the soil C saturation concept. Our model builds on the Microbial Efficiency-Matrix Stabilization framework (Cotrufo et al., 2013) by suggesting the effect of litter quality on SOM stabilization is modulated by the extent of soil C saturation such that high-quality litters are not always stabilized in SOM with greater efficiency than low-quality litters. © 2015 John Wiley & Sons Ltd.
Assuring Quality in Large-Scale Online Course Development
ERIC Educational Resources Information Center
Parscal, Tina; Riemer, Deborah
2010-01-01
Student demand for online education requires colleges and universities to rapidly expand the number of courses and programs offered online while maintaining high quality. This paper outlines two universities respective processes to assure quality in large-scale online programs that integrate instructional design, eBook custom publishing, Quality…
Gass, Jonathon D; Misra, Anamika; Yadav, Mahendra Nath Singh; Sana, Fatima; Singh, Chetna; Mankar, Anup; Neal, Brandon J; Fisher-Bowman, Jennifer; Maisonneuve, Jenny; Delaney, Megan Marx; Kumar, Krishan; Singh, Vinay Pratap; Sharma, Narender; Gawande, Atul; Semrau, Katherine; Hirschhorn, Lisa R
2017-09-07
There are few published standards or methodological guidelines for integrating Data Quality Assurance (DQA) protocols into large-scale health systems research trials, especially in resource-limited settings. The BetterBirth Trial is a matched-pair, cluster-randomized controlled trial (RCT) of the BetterBirth Program, which seeks to improve quality of facility-based deliveries and reduce 7-day maternal and neonatal mortality and maternal morbidity in Uttar Pradesh, India. In the trial, over 6300 deliveries were observed and over 153,000 mother-baby pairs across 120 study sites were followed to assess health outcomes. We designed and implemented a robust and integrated DQA system to sustain high-quality data throughout the trial. We designed the Data Quality Monitoring and Improvement System (DQMIS) to reinforce six dimensions of data quality: accuracy, reliability, timeliness, completeness, precision, and integrity. The DQMIS was comprised of five functional components: 1) a monitoring and evaluation team to support the system; 2) a DQA protocol, including data collection audits and targets, rapid data feedback, and supportive supervision; 3) training; 4) standard operating procedures for data collection; and 5) an electronic data collection and reporting system. Routine audits by supervisors included double data entry, simultaneous delivery observations, and review of recorded calls to patients. Data feedback reports identified errors automatically, facilitating supportive supervision through a continuous quality improvement model. The five functional components of the DQMIS successfully reinforced data reliability, timeliness, completeness, precision, and integrity. The DQMIS also resulted in 98.33% accuracy across all data collection activities in the trial. All data collection activities demonstrated improvement in accuracy throughout implementation. Data collectors demonstrated a statistically significant (p = 0.0004) increase in accuracy throughout consecutive audits. The DQMIS was successful, despite an increase from 20 to 130 data collectors. In the absence of widely disseminated data quality methods and standards for large RCT interventions in limited-resource settings, we developed an integrated DQA system, combining auditing, rapid data feedback, and supportive supervision, which ensured high-quality data and could serve as a model for future health systems research trials. Future efforts should focus on standardization of DQA processes for health systems research. ClinicalTrials.gov identifier, NCT02148952 . Registered on 13 February 2014.
Argumentation Based Joint Learning: A Novel Ensemble Learning Approach
Xu, Junyi; Yao, Li; Li, Le
2015-01-01
Recently, ensemble learning methods have been widely used to improve classification performance in machine learning. In this paper, we present a novel ensemble learning method: argumentation based multi-agent joint learning (AMAJL), which integrates ideas from multi-agent argumentation, ensemble learning, and association rule mining. In AMAJL, argumentation technology is introduced as an ensemble strategy to integrate multiple base classifiers and generate a high performance ensemble classifier. We design an argumentation framework named Arena as a communication platform for knowledge integration. Through argumentation based joint learning, high quality individual knowledge can be extracted, and thus a refined global knowledge base can be generated and used independently for classification. We perform numerous experiments on multiple public datasets using AMAJL and other benchmark methods. The results demonstrate that our method can effectively extract high quality knowledge for ensemble classifier and improve the performance of classification. PMID:25966359
Toward population management in an integrated care model.
Maddux, Franklin W; McMurray, Stephen; Nissenson, Allen R
2013-04-01
Under the Patient Protection and Affordable Care Act of 2010, accountable care organizations (ACOs) will be the primary mechanism for achieving the dual goals of high-quality patient care at managed per capita costs. To achieve these goals in the newly emerging health care environment, the nephrology community must plan for and direct integrated delivery and coordination of renal care, focusing on population management. Even though the ESRD patient population is a complex group with comorbid conditions that may confound integration of care, the nephrology community has unique experience providing integrated care through ACO-like programs. Specifically, the recent ESRD Management Demonstration Project sponsored by the Centers for Medicare & Medicaid Services and the current ESRD Prospective Payment System with it Quality Incentive Program have demonstrated that integrated delivery of renal care can be accomplished in a manner that provides improved clinical outcomes with some financial margin of savings. Moving forward, integrated renal care will probably be linked to provider performance and quality outcomes measures, and clinical integration initiatives will share several common elements, namely performance-based payment models, coordination of communication via health care information technology, and development of best practices for care coordination and resource utilization. Integration initiatives must be designed to be measured and evaluated, and, consistent with principles of continuous quality improvement, each initiative will provide for iterative improvements of the initiative.
Toward population management in an integrated care model.
Maddux, Franklin W; McMurray, Stephen; Nissenson, Allen R
2013-01-01
Under the Patient Protection and Affordable Care Act of 2010, accountable care organizations (ACOs) will be the primary mechanism for achieving the dual goals of high-quality patient care at managed per capita costs. To achieve these goals in the newly emerging health care environment, the nephrology community must plan for and direct integrated delivery and coordination of renal care, focusing on population management. Even though the ESRD patient population is a complex group with comorbid conditions that may confound integration of care, the nephrology community has unique experience providing integrated care through ACO-like programs. Specifically, the recent ESRD Management Demonstration Project sponsored by the Centers for Medicare & Medicaid Services and the current ESRD Prospective Payment System with it Quality Incentive Program have demonstrated that integrated delivery of renal care can be accomplished in a manner that provides improved clinical outcomes with some financial margin of savings. Moving forward, integrated renal care will probably be linked to provider performance and quality outcomes measures, and clinical integration initiatives will share several common elements, namely performance-based payment models, coordination of communication via health care information technology, and development of best practices for care coordination and resource utilization. Integration initiatives must be designed to be measured and evaluated, and, consistent with principles of continuous quality improvement, each initiative will provide for iterative improvements of the initiative. © 2013 S. Karger AG, Basel.
2010-06-01
models 13 The Chi-Square test fails to reject the null hypothesis that there is no difference between 2008 and 2009 data (p-value = 0.601). This...attributed to process performance modeling 53 Table 4: Relationships between data quality and integrity activities and overall value attributed to... data quality and integrity; staffing and resources devoted to the work; pertinent training and coaching; and the alignment of the models with
USDA-ARS?s Scientific Manuscript database
RNA integrity is critical for successful RNA quantification. The level of integrity required differs among sources and extraction procedures and has not been determined for bacterial RNA. Three RNA isolation methods were evaluated for their ability to produce high quality RNA from D. dadantii. The i...
New Integrated Video and Graphics Technology: Digital Video Interactive.
ERIC Educational Resources Information Center
Optical Information Systems, 1987
1987-01-01
Describes digital video interactive (DVI), a new technology which combines the interactivity of the graphics capabilities in personal computers with the realism of high-quality motion video and multitrack audio in an all-digital integrated system. (MES)
All-Optical Wavelength-Path Service With Quality Assurance by Multilayer Integration System
NASA Astrophysics Data System (ADS)
Yagi, Mikio; Tanaka, Shinya; Satomi, Shuichi; Ryu, Shiro; Asano, Shoichiro
2006-09-01
In the future all-optical network controlled by generalized multiprotocol label switching (GMPLS), the wavelength path between end nodes will change dynamically. This inevitably means that the fiber parameters along the wavelength path will also vary. This variation in fiber parameters influences the signal quality of high-speed-transmission system (bit rates over 40 Gb/s). Therefore, at a path setup, the fiber-parameter effect should be adequately compensated. Moreover, the path setup must be completed fast enough to meet the network-application demands. To realize the rapid setup of adequate paths, a multilayer integration system for all-optical wavelength-path quality assurance is proposed. This multilayer integration system is evaluated in a field trial. In the trial, the GMPLS control plane, measurement plane, and data plane coordinated to maintain the quality of a 40-Gb/s wavelength path that would otherwise be degraded by the influence of chromatic dispersion. It is also demonstrated that the multilayer integration system can assure the signal quality in the face of not only chromatic dispersion but also degradation in the optical signal-to-noise ratio by the use of a 2R regeneration system. Our experiments confirm that the proposed multilayer integration system is an essential part of future all-optical networks.
Nandi, Anirban; Pan, Sharadwata; Potumarthi, Ravichandra; Danquah, Michael K; Sarethy, Indira P
2014-01-01
Six Sigma methodology has been successfully applied to daily operations by several leading global private firms including GE and Motorola, to leverage their net profits. Comparatively, limited studies have been conducted to find out whether this highly successful methodology can be applied to research and development (R&D). In the current study, we have reviewed and proposed a process for a probable integration of Six Sigma methodology to large-scale production of Penicillin G and its subsequent conversion to 6-aminopenicillanic acid (6-APA). It is anticipated that the important aspects of quality control and quality assurance will highly benefit from the integration of Six Sigma methodology in mass production of Penicillin G and/or its conversion to 6-APA.
Nandi, Anirban; Danquah, Michael K.
2014-01-01
Six Sigma methodology has been successfully applied to daily operations by several leading global private firms including GE and Motorola, to leverage their net profits. Comparatively, limited studies have been conducted to find out whether this highly successful methodology can be applied to research and development (R&D). In the current study, we have reviewed and proposed a process for a probable integration of Six Sigma methodology to large-scale production of Penicillin G and its subsequent conversion to 6-aminopenicillanic acid (6-APA). It is anticipated that the important aspects of quality control and quality assurance will highly benefit from the integration of Six Sigma methodology in mass production of Penicillin G and/or its conversion to 6-APA. PMID:25057428
An integrative review of health-related quality of life in patients with critical limb ischaemia.
Monaro, Susan; West, Sandra; Gullick, Janice
2017-10-01
To examine the domains and the domain-specific characteristics within a peripheral arterial disease health-related quality of life framework for their usefulness in defining critical limb ischaemia health-related quality of life. Critical Limb Ischaemia presents a highly individualised set of personal and health circumstances. Treatment options include conservative management, revascularisation or amputation. However, the links between treatment decisions and quality of life require further investigation. The framework for this integrative review was the peripheral arterial disease-specific health-related quality of life domains identified by Treat-Jacobson et al. The literature expanded and refined Treat-Jacobson's framework by modifying the characteristics to better describe health-related quality of life in critical limb ischaemia. Given that critical limb ischaemia is a highly individualised situation with powerful health-related quality of life implications, further research focusing on patient and family-centred decision-making relating to therapeutic options and advanced care planning is required. A critical limb ischaemia-specific, health-related quality of life tool is required to capture both the unique characteristics of this disorder, and the outcomes for active or conservative care among this complex group of patients. © 2016 John Wiley & Sons Ltd.
Feldmesser, Ester; Rosenwasser, Shilo; Vardi, Assaf; Ben-Dor, Shifra
2014-02-22
The advent of Next Generation Sequencing technologies and corresponding bioinformatics tools allows the definition of transcriptomes in non-model organisms. Non-model organisms are of great ecological and biotechnological significance, and consequently the understanding of their unique metabolic pathways is essential. Several methods that integrate de novo assembly with genome-based assembly have been proposed. Yet, there are many open challenges in defining genes, particularly where genomes are not available or incomplete. Despite the large numbers of transcriptome assemblies that have been performed, quality control of the transcript building process, particularly on the protein level, is rarely performed if ever. To test and improve the quality of the automated transcriptome reconstruction, we used manually defined and curated genes, several of them experimentally validated. Several approaches to transcript construction were utilized, based on the available data: a draft genome, high quality RNAseq reads, and ESTs. In order to maximize the contribution of the various data, we integrated methods including de novo and genome based assembly, as well as EST clustering. After each step a set of manually curated genes was used for quality assessment of the transcripts. The interplay between the automated pipeline and the quality control indicated which additional processes were required to improve the transcriptome reconstruction. We discovered that E. huxleyi has a very high percentage of non-canonical splice junctions, and relatively high rates of intron retention, which caused unique issues with the currently available tools. While individual tools missed genes and artificially joined overlapping transcripts, combining the results of several tools improved the completeness and quality considerably. The final collection, created from the integration of several quality control and improvement rounds, was compared to the manually defined set both on the DNA and protein levels, and resulted in an improvement of 20% versus any of the read-based approaches alone. To the best of our knowledge, this is the first time that an automated transcript definition is subjected to quality control using manually defined and curated genes and thereafter the process is improved. We recommend using a set of manually curated genes to troubleshoot transcriptome reconstruction.
Key Elements for Judging the Quality of a Risk Assessment
Fenner-Crisp, Penelope A.; Dellarco, Vicki L.
2016-01-01
Background: Many reports have been published that contain recommendations for improving the quality, transparency, and usefulness of decision making for risk assessments prepared by agencies of the U.S. federal government. A substantial measure of consensus has emerged regarding the characteristics that high-quality assessments should possess. Objective: The goal was to summarize the key characteristics of a high-quality assessment as identified in the consensus-building process and to integrate them into a guide for use by decision makers, risk assessors, peer reviewers and other interested stakeholders to determine if an assessment meets the criteria for high quality. Discussion: Most of the features cited in the guide are applicable to any type of assessment, whether it encompasses one, two, or all four phases of the risk-assessment paradigm; whether it is qualitative or quantitative; and whether it is screening level or highly sophisticated and complex. Other features are tailored to specific elements of an assessment. Just as agencies at all levels of government are responsible for determining the effectiveness of their programs, so too should they determine the effectiveness of their assessments used in support of their regulatory decisions. Furthermore, if a nongovernmental entity wishes to have its assessments considered in the governmental regulatory decision-making process, then these assessments should be judged in the same rigorous manner and be held to similar standards. Conclusions: The key characteristics of a high-quality assessment can be summarized and integrated into a guide for judging whether an assessment possesses the desired features of high quality, transparency, and usefulness. Citation: Fenner-Crisp PA, Dellarco VL. 2016. Key elements for judging the quality of a risk assessment. Environ Health Perspect 124:1127–1135; http://dx.doi.org/10.1289/ehp.1510483 PMID:26862984
Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin
2014-07-01
To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
O'Brien, J K; Steinman, K J; Montano, G A; Love, C C; Saiers, R L; Robeck, T R
2013-01-01
The in vitro quality of spermatozoa from one elephant (Elephas maximus) was examined after chilled storage and directional freezing (DF). High-quality, non-contaminated ejaculates (77.6±6.0% progressive motility, 3.9±1.5 µg creatinine mL(-1) raw semen, 2.7±0.6% detached heads) were cryopreserved after 0 (0hStor), 12 (12hStor) and 24 h (24hStor) of chilled storage. At 0 h and 6h post-thawing, total motility, plasma membrane integrity, acrosome integrity, mitochondrial activity and normal morphology were similar (P>0.05) across treatments. In contrast, progressive motility, rapid velocity and several kinematic parameters were lower (P<0.05) for 24Stor compared with 0hStor at 0 h post-thaw. By 6 h post-thaw, amplitude of lateral head displacement and velocity parameters (average pathway, straight-line and curvilinear velocity) were lower (P<0.05) for 24hStor compared with 0hStor and 12hStor. DNA integrity was high and remained unchanged (P>0.05) across all groups and processing stages (1.6±0.6% of cells contained fragmented DNA). Results indicate that DF after up to 12 h of chilled storage results in a post-thaw sperm population of acceptable quality for artificial insemination. These findings have implications for the cryopreservation of sex-sorted spermatozoa, which typically undergo more than 12 h of chilled storage prior to sorting and preservation.
Mel'tser, A V; Erastova, N V; Kiselev, A V
2013-01-01
Providing population with quality drinking water--one of the priority tasks of the state policy aimed at maintaining the health of citizens. Hygienic rating of the drinking water quality envisages requirements to assurance its safety in the epidemiological and radiation relations, harmlessness of chemical composition and good organoleptic properties. There are numerous data proving the relationship between the chemical composition of drinking water and human health, and therefore the issue of taking a hygienically sound measures to improve the efficiency of water treatment has more and more priority. High water quality--the result of complex solution of tasks, including an integral approach to assessment of the quality of drinking water the use of hygienically sound decisions in the modernization of water treatment systems. The results of the integral assessment of drinking water on the properties of harmlessness have shown its actuality in the development and implementation of management decisions. The use of the spatial characteristics of integrated indices permits to visualize changes in the quality of drinking water in all stages of production and transportation from the position of health risks, evaluate the effectiveness of technological solutions and set priorities for investing.
High quality factor single-crystal diamond mechanical resonators
NASA Astrophysics Data System (ADS)
Ovartchaiyapong, P.; Pascal, L. M. A.; Myers, B. A.; Lauria, P.; Bleszynski Jayich, A. C.
2012-10-01
Single-crystal diamond is a promising material for microelectromechanical systems (MEMs) because of its low mechanical loss, compatibility with extreme environments, and built-in interface to high-quality spin centers. But its use has been limited by challenges in processing and growth. We demonstrate a wafer bonding-based technique to form diamond on insulator, from which we make single-crystal diamond micromechanical resonators with mechanical quality factors as high as 338 000 at room temperature. Variable temperature measurements down to 10 K reveal a nonmonotonic dependence of quality factor on temperature. These resonators enable integration of single-crystal diamond into MEMs technology for classical and quantum applications.
Presence of indicator plant species as a predictor of wetland vegetation integrity
Stapanian, Martin A.; Adams, Jean V.; Gara, Brian
2013-01-01
We fit regression and classification tree models to vegetation data collected from Ohio (USA) wetlands to determine (1) which species best predict Ohio vegetation index of biotic integrity (OVIBI) score and (2) which species best predict high-quality wetlands (OVIBI score >75). The simplest regression tree model predicted OVIBI score based on the occurrence of three plant species: skunk-cabbage (Symplocarpus foetidus), cinnamon fern (Osmunda cinnamomea), and swamp rose (Rosa palustris). The lowest OVIBI scores were best predicted by the absence of the selected plant species rather than by the presence of other species. The simplest classification tree model predicted high-quality wetlands based on the occurrence of two plant species: skunk-cabbage and marsh-fern (Thelypteris palustris). The overall misclassification rate from this tree was 13 %. Again, low-quality wetlands were better predicted than high-quality wetlands by the absence of selected species rather than the presence of other species using the classification tree model. Our results suggest that a species’ wetland status classification and coefficient of conservatism are of little use in predicting wetland quality. A simple, statistically derived species checklist such as the one created in this study could be used by field biologists to quickly and efficiently identify wetland sites likely to be regulated as high-quality, and requiring more intensive field assessments. Alternatively, it can be used for advanced determinations of low-quality wetlands. Agencies can save considerable money by screening wetlands for the presence/absence of such “indicator” species before issuing permits.
Li, Ke; Li, Junfang; Su, Jin; Xiao, Xuefeng; Peng, Xiujuan; Liu, Feng; Li, Defeng; Zhang, Yi; Chong, Tao; Xu, Haiyu; Liu, Changxiao; Yang, Hongjun
2018-03-07
The quality evaluation of traditional Chinese medicine (TCM) formulations is needed to guarantee the safety and efficacy. In our laboratory, we established interaction rules between chemical quality control and biological activity evaluations to study Yuanhu Zhitong tablets (YZTs). Moreover, a quality marker (Q-marker) has recently been proposed as a new concept in the quality control of TCM. However, no appropriate methods are available for the identification of Q-markers from the complex TCM systems. We aimed to use an integrative pharmacological (IP) approach to further identify Q-markers from YZTs through the integration of multidisciplinary knowledge. In addition, data mining was used to determine the correlation between multiple constituents of this TCM and its bioactivity to improve quality control. The IP approach was used to identify the active constituents of YZTs and elucidate the molecular mechanisms by integrating chemical and biosynthetic analyses, drug metabolism, and network pharmacology. Data mining methods including grey relational analysis (GRA) and least squares support vector machine (LS-SVM) regression techniques, were used to establish the correlations among the constituents and efficacy, and dose efficacy in multiple dimensions. Seven constituents (tetrahydropalmatine, α-allocryptopine, protopine, corydaline, imperatorin, isoimperatorin, and byakangelicin) were identified as Q-markers of YZT using IP based on their high abundance, specific presence in the individual herbal constituents and the product, appropriate drug-like properties, and critical contribution to the bioactivity of the mixture of YZT constituents. Moreover, three Q-markers (protopine, α-allocryptopine, and corydaline) were highly correlated with the multiple bioactivities of the YZTs, as found using data mining. Finally, three constituents (tetrahydropalmatine, corydaline, and imperatorin) were chosen as minimum combinations that both distinguished the authentic components from false products and indicated the intensity of bioactivity to improve the quality control of YZTs. Tetrahydropalmatine, imperatorin, and corydaline could be used as minimum combinations to effectively control the quality of YZTs. Copyright © 2018. Published by Elsevier GmbH.
Integrated synoptic surveys using an autonomous underwater vehicle and manned boats
Jackson, P. Ryan
2013-01-01
Traditional surface-water surveys are being combined with autonomous technology to produce integrated surveys of bathymetry, water quality, and velocity in inland lakes and reservoirs. This new technology provides valuable, high-resolution, integrated data that allow a systems-based approach to understanding common environmental problems. This fact sheet presents several example applications of integrated surveys within inland lakes and coastal Lake Michigan and Lake Erie.
High beam quality and high energy short-pulse laser with MOPA
NASA Astrophysics Data System (ADS)
Jin, Quanwei; Pang, Yu; Jiang, JianFeng; Tan, Liang; Cui, Lingling; Wei, Bin; Sun, Yinhong; Tang, Chun
2018-03-01
A high energy, high beam quality short-pulse diode-pumped Nd:YAG master oscillator power-amplifier (MOPA) laser with two amplifier stages is demonstrated. The two-rod birefringence compensation was used as beam quality controlling methods, which presents a short-pulse energy of 40 mJ with a beam quality value of M2 = 1.2 at a repetition rate of 400Hz. The MOPA system delivers a short-pulse energy of 712.5 mJ with a pulse width of 12.4 ns.The method of spherical aberration compensation is improved the beam quality, a M2 factor of 2.3 and an optical-to-optical efficiency of 27.7% is obtained at the maximum laser out power.The laser obtained 1.4J out energy with polarization integration.
Deterministic Coupling of Quantum Emitters in 2D Materials to Plasmonic Nanocavity Arrays.
Tran, Toan Trong; Wang, Danqing; Xu, Zai-Quan; Yang, Ankun; Toth, Milos; Odom, Teri W; Aharonovich, Igor
2017-04-12
Quantum emitters in two-dimensional materials are promising candidates for studies of light-matter interaction and next generation, integrated on-chip quantum nanophotonics. However, the realization of integrated nanophotonic systems requires the coupling of emitters to optical cavities and resonators. In this work, we demonstrate hybrid systems in which quantum emitters in 2D hexagonal boron nitride (hBN) are deterministically coupled to high-quality plasmonic nanocavity arrays. The plasmonic nanoparticle arrays offer a high-quality, low-loss cavity in the same spectral range as the quantum emitters in hBN. The coupled emitters exhibit enhanced emission rates and reduced fluorescence lifetimes, consistent with Purcell enhancement in the weak coupling regime. Our results provide the foundation for a versatile approach for achieving scalable, integrated hybrid systems based on low-loss plasmonic nanoparticle arrays and 2D materials.
We developed an estuarine index of biotic integrity to assess habitat quality in Narragansett Bay, Rhode Island. Fish were collected with a 61 X 3.05 m beach seine monthly in July and August from 1988-1999 at 18 fixed stations. Stations were designated high or low quality dependi...
[Development of a scale to measure Korean ego-integrity in older adults].
Chang, Sung Ok; Kong, Eun Sook; Kim, Kwuy Bun; Kim, Nam Cho; Kim, Ju Hee; Kim, Chun Gill; Kim, Hee Kyung; Song, Mi Soon; Ahn, Soo Yeon; Lee, Kyung Ja; Lee, Young Whee; Chon, Si Ja; Cho, Nam Ok; Cho, Myung Ok; Choi, Kyung Sook
2007-04-01
Ego-integrity in older adults is the central concept related to quality of life in later life. Therefore, for effective interventions to enhance the quality of later life, a scale to measure ego-integrity in older adults is necessary. This study was carried out to develop a scale to measure ego-integrity in older adults. This study utilized cronbach's alpha in analyzing the reliability of the collected data and expert group, and factor analysis and item analysis to analyze validity. Seventeen items were selected from a total of 21 items. Cronbach's alpha coefficient for internal consistency was .88 for the 17 items of ego-integrity in the older adults scale. Three factors evolved by factor analysis, which explained 50.71% of the total variance. The scale for measuring ego-integrity in Korean older adults in this study was evaluated as a tool with a high degree of reliability and validity.
Golden, Angela; Miller, Kenneth
2014-06-01
Nurse practitioners have long included high-quality behavioral health in the care they provide to individuals and families nationwide. Just as the principles of the medical home have been an integral part of nurse practitioners' practice, so has the concept of whole person orientation incorporating both physical and mental or behavioral health care. It is therefore encouraging that organized medicine has embraced integrated physical and behavioral health care in patient-centered medical homes, a position that could help improve the wellbeing of patients all throughout the United States. Although the American Association of Nurse Practitioners (AANP) has long supported such integration, we do not support the physician-centric joint principles included in the current issue of Annals of Family Medicine (The Working Party Group on Integrated Behavioral Healthcare et al., 2014), as they create provider and leadership roles that are too narrow and restrictive for the provision of health care in the 21st century. As written, they limit access to high-quality care and restrict patient choice of health care providers.
Midlands Teaching Factory, LTD.
ERIC Educational Resources Information Center
Midlands Technical Coll., Columbia, SC.
In 1987, Midlands Technical College (MTC), in Columbia, South Carolina, initiated a Computer Integrated Manufacturing (CIM) project, the Midlands Teaching Factory, LTD, which integrated various college departments with the goal of manufacturing a high quality, saleable product. The faculty developed a teaching factory model which was designed to…
Integrated Aerodynamic and Control System Design of Oblique Wing Aircraft. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Morris, Stephen James
1990-01-01
An efficient high speed aircraft design must achieve a high lift to drag ratio at transonic and supersonic speeds. In 1952 Dr. R. T. Jones proved that for any flight Mach number minimum drag at a fixed lift is achieved by an elliptic wing planform with an appropriate oblique sweep angle. Since then, wind tunnel tests and numerical flow models have confirmed that the compressibility drag of oblique wing aircraft is lower than similar symmetrical sweep designs. At oblique sweep angles above thirty degrees the highly asymmetric planform gives rise to aerodynamic and inertia couplings which affect stability and degrade the aircraft's handling qualities. In the case of the NASA-Rockwell Oblique Wing Research Aircraft, attempts to improve the handling qualities by implementing a stability augmentation system have produced unsatisfactory results because of an inherent lack of controllability in the proposed design. The present work focuses on improving the handling qualities of oblique wing aircraft by including aerodynamic configuration parameters as variables in the control system synthesis to provide additional degrees of freedom with which to further decouple the aircraft's response. Handling qualities are measured using a quadratic cost function identical to that considered in optimal control problems, but the controller architecture is not restricted to full state feedback. An optimization procedure is used to simultaneously solve for the aircraft configuration and control gains which maximize a handling qualities measure, while meeting imposed constraints on trim. In some designs wing flexibility is also modeled and reduced order controllers are implemented. Oblique wing aircraft synthesized by this integrated design method show significant improvement in handling qualities when compared to the originally proposed closed loop aircraft. The integrated design synthesis method is then extended to show how handling qualities may be traded for other types of mission performance (drag, weight, etc.). Examples are presented which show how performance can be maximized while maintaining a desired level of handling quality.
Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert
2017-02-01
In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.
An Improved Power Quality BIBRED Converter-Based VSI-Fed BLDC Motor Drive
NASA Astrophysics Data System (ADS)
Singh, Bhim; Bist, Vashist
2014-01-01
This paper presents an IHQRR (integrated high-quality rectifier regulator) BIBRED (boost integrated buck rectifier energy storage DC-DC) converter-based VSI (voltage source inverter)-fed BLDC (brushless DC) motor drive. The speed control of BLDC motor is achieved by controlling the DC link voltage of the VSI using a single voltage sensor. This allows VSI to operate in fundamental frequency switching mode for electronic commutation of BLDC motor which reduces the switching losses due to high-frequency switching used in conventional approach of PWM (pulse width modulation)-based VSI-fed BLDC motor drive. A BIBRED converter is operated in a dual-DCM (discontinuous conduction mode) thus using a voltage follower approach for PFC (power factor correction) and DC link voltage control. The performance of the proposed drive is evaluated for improved power quality over a wide range of speed control and supply voltage variation for demonstrating the behavior of proposed drive. The power quality indices thus obtained are within the recommended limits by international PQ (power quality) standards such as IEC 61000-3-2.
LIHE Spectral Dynamics and Jaguar Data Acquisition System Measurement Assurance Results 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Covert, Timothy T.; Willis, Michael David; Radtke, Gregg Arthur
2015-06-01
The Light Initiated High Explosive (LIHE) facility performs high rigor, high consequence impulse testing for the nuclear weapons (NW) community. To support the facility mission, LIHE's extensive data acquisition system (DAS) is comprised of several discrete components as well as a fully integrated system. Due to the high consequence and high rigor of the testing performed at LIHE, a measurement assurance plan (MAP) was developed in collaboration with NW system customers to meet their data quality needs and to provide assurance of the robustness of the LIHE DAS. While individual components of the DAS have been calibrated by the SNLmore » Primary Standards Laboratory (PSL), the integrated nature of this complex system requires verification of the complete system, from end-to-end. This measurement assurance plan (MAP) report documents the results of verification and validation procedures used to ensure that the data quality meets customer requirements.« less
Zhang, Ding-kun; Wang, Jia-bo; Yang, Ming; Peng, Cheng; Xiao, Xiao-he
2015-07-01
Good medicinal herbs, good drugs. Good evaluation method and indices are the prerequisite of good medicinal herbs. However, there exist numerous indices for quality evaluation and control in Chinese medicinal materials. However, most of these indices are non-interrelated each other, as well as having little relationship with efficiency and safety. The results of different evaluatior methods may not be consistent, even contradictory. Considering the complex material properties of Chinese medicinal materials, single method and index is difficult to objectively and comprehensively reflect the quality. Therefore, it is essential to explore the integrated evaluation methods. In this paper, oriented by the integrated evaluation strategies for traditional Chinese medicine quality, a new method called integrated quality index (IQI) by the integration of empirical evaluation, chemical evaluation, and biological evaluation was proposed. In addition, a study case of hypertoxic herb Aconitum carmichaelii Debx. was provided to explain this method in detail. The results suggested that in the view of specifications, the average weight of Jiangyou aconite was the greatest, followed by Weishan aconite, Butuo aconite, Hanzhong aconite, and Anxian aconite; from the point of chemical components, Jiangyou aconite had the characteristic with strong efficacy and weak toxicity, next was Hanzhong aconite, Butuo aconite, Weishan aconite, and Anxian aconite; taking toxicity price as the index, Hanzhong aconite and Jiangyou aconite have the lower toxicity, while Butuo aconite, Weishan aconite, and Anxian aconite have the relatively higher one. After the normalization and integration of evaluation results, we calculated the IQI value of Jiangyou aconite, Hanzhong aconite, Butuo aconite, Weishan aconite, and Anxian aconite were 0.842 +/- 0.091, 0.597 +/- 0.047, 0.442 +/- 0.033, 0.454 +/- 0.038, 0.170 +/- 0.021, respectively. The quality of Jiangyou aconite is significantly better than the others (P < 0.05) followed by Hanzhong aconite, which is consistent with the traditional understanding of genuineness. It can be concluded that IQI achieves the integrated control and evaluation for the quality of Chinese medicinal materials, and it is an exploration for building the good medicinal herbs standards. In addition, IQI provides technical supports for the geoherbalism evaluation, selective breeding, the development of precision decoction pieces, high quality and favourable price in market circulation, and rational drug use.
Glurich, Ingrid; Nycz, Gregory; Acharya, Amit
2017-06-01
Escalating prevalence of both diabetes and periodontal disease, two diseases associated with bi-directional exacerbation, has been reported. Periodontal disease represents a modifiable risk factor that may reduce diabetes onset or progression, and integrated models of cross-disciplinary care are needed to establish and manage glycemic control in affected patients. An ad-hoc environmental scan of current literature and media sought to characterize factors impacting status of integrated care models based on review of the existing evidence base in literature and media surrounding: (1) current cross-disciplinary practice patterns, (2) epidemiological updates, (3) status on risk assessment and screening for dysglycemia in the dental setting, (4) status on implementation of quality metrics for oral health, (5) care model pilots, and (6) public health perspectives. The survey revealed: escalating prevalence of diabetes and periodontitis globally; greater emphasis on oral health assessment for diabetic patients in recent medical clinical practice guidelines; high knowledgeability surrounding oral-systemic impacts on diabetes and growing receptivity to medical-dental integration among medical and dental providers; increasing numbers of programs/studies reporting on positive impact of emerging integrated dental-medical care models on diabetic patient healthcare access and health outcomes; a growing evidence base for clinically significant rates of undiagnosed dysglycemia among dental patients reported by point-of-care pilot studies; no current recommendation for population-based screening for dysglycemia in dental settings pending a stronger evidence base; improved definition of true periodontitis prevalence in (pre)/diabetics; emerging recognition of the need for oral health quality indicators and tracking; evidence of persistence in dental access disparity; updated status on barriers to integration. The potential benefit of creating clinically-applicable integrated care models to support holistic management of an escalating diabetic population by targeting modifiable risk factors including periodontitis is being recognized by the health industry. Cross-disciplinary efforts supported by high quality research are needed to mitigate previously- and newly-defined barriers of care integration and expedite development and implementation of integrated care models in various practice settings. Implementation of quality monitoring in the dental setting will support definition of the impact and efficacy of interventional clinical care models on patient outcomes. © 2017 Marshfield Clinic.
Integrating automated support for a software management cycle into the TAME system
NASA Technical Reports Server (NTRS)
Sunazuka, Toshihiko; Basili, Victor R.
1989-01-01
Software managers are interested in the quantitative management of software quality, cost and progress. An integrated software management methodology, which can be applied throughout the software life cycle for any number purposes, is required. The TAME (Tailoring A Measurement Environment) methodology is based on the improvement paradigm and the goal/question/metric (GQM) paradigm. This methodology helps generate a software engineering process and measurement environment based on the project characteristics. The SQMAR (software quality measurement and assurance technology) is a software quality metric system and methodology applied to the development processes. It is based on the feed forward control principle. Quality target setting is carried out before the plan-do-check-action activities are performed. These methodologies are integrated to realize goal oriented measurement, process control and visual management. A metric setting procedure based on the GQM paradigm, a management system called the software management cycle (SMC), and its application to a case study based on NASA/SEL data are discussed. The expected effects of SMC are quality improvement, managerial cost reduction, accumulation and reuse of experience, and a highly visual management reporting system.
Seasonal variations on sugarcane trash quantity and quality that directly concern refiners
USDA-ARS?s Scientific Manuscript database
There is a trend in the U.S. and world-wide to produce very high pol (VHP) and very low color (VLC) raw sugars for vertical integration from the field to the refinery. Great variations in the color and quality of raw and VHP/VLC sugars exist mostly because of the range in quality of the cane supply...
O'Brien, J K; Roth, T L; Stoops, M A; Ball, R L; Steinman, K J; Montano, G A; Love, C C; Robeck, T R
2015-01-01
White rhinoceros ejaculates (n=9) collected by electroejaculation from four males were shipped (10°C, 12h) to develop procedures for the production of chilled and frozen-thawed sex-sorted spermatozoa of adequate quality for artificial insemination (AI). Of all electroejaculate fractions, 39.7% (31/78) exhibited high quality post-collection (≥70% total motility and membrane integrity) and of those, 54.8% (17/31) presented reduced in vitro quality after transport and were retrospectively determined to exhibit urine-contamination (≥21.0μg creatinine/ml). Of fractions analyzed for creatinine concentration, 69% (44/64) were classified as urine-contaminated. For high quality non-contaminated fractions, in vitro parameters (motility, velocity, membrane, acrosome and DNA integrity) of chilled non-sorted and sorted spermatozoa were well-maintained at 5°C up to 54h post-collection, whereby >70% of post-transport (non-sorted) or post-sort (sorted) values were retained. By 54h post-collection, some motility parameters were higher (P<0.05) for non-sorted spermatozoa (total motility, rapid velocity, average path velocity) whereas all remaining motion parameters as well as membrane, acrosome and DNA integrity were similar between sperm types. In comparison with a straw method, directional freezing resulted in enhanced (P<0.05) motility and velocity of non-sorted and sorted spermatozoa, with comparable overall post-thaw quality between sperm types. High purity enrichment of X-bearing (89±6%) or Y-bearing (86±3%) spermatozoa was achieved using moderate sorting rates (2540±498X-spermatozoa/s; 1800±557Y-spermatozoa/s). Collective in vitro characteristics of sorted-chilled or sorted-frozen-thawed spermatozoa derived from high quality electroejaculates indicate acceptable fertility potential for use in AI. Copyright © 2014 Elsevier B.V. All rights reserved.
Lin, Xiaotong; Liu, Mei; Chen, Xue-wen
2009-04-29
Protein-protein interactions play vital roles in nearly all cellular processes and are involved in the construction of biological pathways such as metabolic and signal transduction pathways. Although large-scale experiments have enabled the discovery of thousands of previously unknown linkages among proteins in many organisms, the high-throughput interaction data is often associated with high error rates. Since protein interaction networks have been utilized in numerous biological inferences, the inclusive experimental errors inevitably affect the quality of such prediction. Thus, it is essential to assess the quality of the protein interaction data. In this paper, a novel Bayesian network-based integrative framework is proposed to assess the reliability of protein-protein interactions. We develop a cross-species in silico model that assigns likelihood scores to individual protein pairs based on the information entirely extracted from model organisms. Our proposed approach integrates multiple microarray datasets and novel features derived from gene ontology. Furthermore, the confidence scores for cross-species protein mappings are explicitly incorporated into our model. Applying our model to predict protein interactions in the human genome, we are able to achieve 80% in sensitivity and 70% in specificity. Finally, we assess the overall quality of the experimentally determined yeast protein-protein interaction dataset. We observe that the more high-throughput experiments confirming an interaction, the higher the likelihood score, which confirms the effectiveness of our approach. This study demonstrates that model organisms certainly provide important information for protein-protein interaction inference and assessment. The proposed method is able to assess not only the overall quality of an interaction dataset, but also the quality of individual protein-protein interactions. We expect the method to continually improve as more high quality interaction data from more model organisms becomes available and is readily scalable to a genome-wide application.
Yang, Tiefeng; Zheng, Biyuan; Wang, Zhen; Xu, Tao; Pan, Chen; Zou, Juan; Zhang, Xuehong; Qi, Zhaoyang; Liu, Hongjun; Feng, Yexin; Hu, Weida; Miao, Feng; Sun, Litao; Duan, Xiangfeng; Pan, Anlian
2017-12-04
High-quality two-dimensional atomic layered p-n heterostructures are essential for high-performance integrated optoelectronics. The studies to date have been largely limited to exfoliated and restacked flakes, and the controlled growth of such heterostructures remains a significant challenge. Here we report the direct van der Waals epitaxial growth of large-scale WSe 2 /SnS 2 vertical bilayer p-n junctions on SiO 2 /Si substrates, with the lateral sizes reaching up to millimeter scale. Multi-electrode field-effect transistors have been integrated on a single heterostructure bilayer. Electrical transport measurements indicate that the field-effect transistors of the junction show an ultra-low off-state leakage current of 10 -14 A and a highest on-off ratio of up to 10 7 . Optoelectronic characterizations show prominent photoresponse, with a fast response time of 500 μs, faster than all the directly grown vertical 2D heterostructures. The direct growth of high-quality van der Waals junctions marks an important step toward high-performance integrated optoelectronic devices and systems.
Geoinformatics 2007: data to knowledge
Brady, Shailaja R.; Sinha, A. Krishna; Gundersen, Linda C.
2007-01-01
Geoinformatics is the term used to describe a variety of efforts to promote collaboration between the computer sciences and the geosciences to solve complex scientific questions. It refers to the distributed, integrated digital information system and working environment that provides innovative means for the study of the Earth systems, as well as other planets, through use of advanced information technologies. Geoinformatics activities range from major research and development efforts creating new technologies to provide high-quality, sustained production-level services for data discovery, integration and analysis, to small, discipline-specific efforts that develop earth science data collections and data analysis tools serving the needs of individual communities. The ultimate vision of Geoinformatics is a highly interconnected data system populated with high quality, freely available data, as well as, a robust set of software for analysis, visualization, and modeling.
High Quality Data for Grid Integration Studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clifton, Andrew; Draxl, Caroline; Sengupta, Manajit
As variable renewable power penetration levels increase in power systems worldwide, renewable integration studies are crucial to ensure continued economic and reliable operation of the power grid. The existing electric grid infrastructure in the US in particular poses significant limitations on wind power expansion. In this presentation we will shed light on requirements for grid integration studies as far as wind and solar energy are concerned. Because wind and solar plants are strongly impacted by weather, high-resolution and high-quality weather data are required to drive power system simulations. Future data sets will have to push limits of numerical weather predictionmore » to yield these high-resolution data sets, and wind data will have to be time-synchronized with solar data. Current wind and solar integration data sets are presented. The Wind Integration National Dataset (WIND) Toolkit is the largest and most complete grid integration data set publicly available to date. A meteorological data set, wind power production time series, and simulated forecasts created using the Weather Research and Forecasting Model run on a 2-km grid over the continental United States at a 5-min resolution is now publicly available for more than 126,000 land-based and offshore wind power production sites. The National Solar Radiation Database (NSRDB) is a similar high temporal- and spatial resolution database of 18 years of solar resource data for North America and India. The need for high-resolution weather data pushes modeling towards finer scales and closer synchronization. We also present how we anticipate such datasets developing in the future, their benefits, and the challenges with using and disseminating such large amounts of data.« less
Zaytsev, Yury V; Morrison, Abigail
2012-01-01
High quality neuroscience research requires accurate, reliable and well maintained neuroinformatics applications. As software projects become larger, offering more functionality and developing a denser web of interdependence between their component parts, we need more sophisticated methods to manage their complexity. If complexity is allowed to get out of hand, either the quality of the software or the speed of development suffer, and in many cases both. To address this issue, here we develop a scalable, low-cost and open source solution for continuous integration (CI), a technique which ensures the quality of changes to the code base during the development procedure, rather than relying on a pre-release integration phase. We demonstrate that a CI-based workflow, due to rapid feedback about code integration problems and tracking of code health measures, enabled substantial increases in productivity for a major neuroinformatics project and additional benefits for three further projects. Beyond the scope of the current study, we identify multiple areas in which CI can be employed to further increase the quality of neuroinformatics projects by improving development practices and incorporating appropriate development tools. Finally, we discuss what measures can be taken to lower the barrier for developers of neuroinformatics applications to adopt this useful technique.
Zaytsev, Yury V.; Morrison, Abigail
2013-01-01
High quality neuroscience research requires accurate, reliable and well maintained neuroinformatics applications. As software projects become larger, offering more functionality and developing a denser web of interdependence between their component parts, we need more sophisticated methods to manage their complexity. If complexity is allowed to get out of hand, either the quality of the software or the speed of development suffer, and in many cases both. To address this issue, here we develop a scalable, low-cost and open source solution for continuous integration (CI), a technique which ensures the quality of changes to the code base during the development procedure, rather than relying on a pre-release integration phase. We demonstrate that a CI-based workflow, due to rapid feedback about code integration problems and tracking of code health measures, enabled substantial increases in productivity for a major neuroinformatics project and additional benefits for three further projects. Beyond the scope of the current study, we identify multiple areas in which CI can be employed to further increase the quality of neuroinformatics projects by improving development practices and incorporating appropriate development tools. Finally, we discuss what measures can be taken to lower the barrier for developers of neuroinformatics applications to adopt this useful technique. PMID:23316158
A Physician's Perspective On Vertical Integration.
Berenson, Robert A
2017-09-01
Vertical integration has been a central feature of health care delivery system change for more than two decades. Recent studies have demonstrated that vertically integrated health care systems raise prices and costs without observable improvements in quality, despite many theoretical reasons why cost control and improved quality might occur. Less well studied is how physicians view their newfound partnerships with hospitals. In this article I review literature findings and other observations on five aspects of vertical integration that affect physicians in their professional and personal lives: patients' access to physicians, physician compensation, autonomy versus system support, medical professionalism and culture, and lifestyle. I conclude that the movement toward physicians' alignment with and employment in vertically integrated systems seems inexorable but that policy should not promote such integration either intentionally or inadvertently. Instead, policy should address the flaws in current payment approaches that reward high prices and excessive service use-outcomes that vertical integration currently produces. Project HOPE—The People-to-People Health Foundation, Inc.
38 CFR 36.4348 - Servicer Appraisal Processing Program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirement, routine reviews of SAPP cases will be made by VA staff based upon quality control procedures..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
38 CFR 36.4348 - Servicer Appraisal Processing Program.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirement, routine reviews of SAPP cases will be made by VA staff based upon quality control procedures..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
38 CFR 36.4348 - Servicer Appraisal Processing Program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirement, routine reviews of SAPP cases will be made by VA staff based upon quality control procedures..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
38 CFR 36.4348 - Servicer Appraisal Processing Program.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirement, routine reviews of SAPP cases will be made by VA staff based upon quality control procedures..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
USDA-ARS?s Scientific Manuscript database
Recent research suggests labile plant litters promote the stabilization of soil organic matter (SOM) in physico-chemically protected fractions with relatively slow turnover. However, the effect of litter quality on SOM stabilization is inconsistent. Labile, ‘high quality’ litters characterized by hi...
Method Optimization for Extracting High-Quality RNA From the Human Pancreas Tissue.
Jun, Eunsung; Oh, Juyun; Lee, Song; Jun, Hye-Ryeong; Seo, Eun Hye; Jang, Jin-Young; Kim, Song Cheol
2018-06-01
Nucleic acid sequencing is frequently used to determine the molecular basis of diseases. Therefore, proper storage of biological specimens is essential to inhibit nucleic acid degradation. RNA isolated from the human pancreas is generally of poor quality because of its high concentration of endogenous RNase. In this study, we optimized the method for extracting high quality RNA from paired tumor and normal pancreatic tissues obtained from eight pancreatic cancer patients post-surgery. RNA integrity number (RIN) was checked to evaluate the integrity of RNA, we tried to extract the RNA with an RIN value of 8 or higher that allows for the latest genetic analysis. The effect of several parameters, including the method used for tissue lysis, RNAlater treatment, tissue weight at storage, and the time to storage after surgical resection, on the quantity and quality of RNA extracted was examined. Data showed that the highest quantity of RNA was isolated using a combination of manual and mechanical methods of tissue lysis. Additionally, sectioning the tissues into small pieces (<100 mg) and treating them with RNAlater solution prior to storage increased RNA stability. Following these guidelines, high quality RNA was obtained from 100% (8/8) of tumor tissues and 75% (6/8) of normal tissues. High-quality RNA was still stable under repeated freezing and thawing. The application of these results during sample handling and storage in clinical settings will facilitate the genetic diagnosis of diseases and their subsequent treatment. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Moan, T.
2017-12-01
An overview of integrity management of offshore structures, with emphasis on the oil and gas energy sector, is given. Based on relevant accident experiences and means to control the associated risks, accidents are categorized from a technical-physical as well as human and organizational point of view. Structural risk relates to extreme actions as well as structural degradation. Risk mitigation measures, including adequate design criteria, inspection, repair and maintenance as well as quality assurance and control of engineering processes, are briefly outlined. The current status of risk and reliability methodology to aid decisions in the integrity management is briefly reviewed. Finally, the need to balance the uncertainties in data, methods and computational efforts and the cautious use and quality assurance and control in applying high fidelity methods to avoid human errors, is emphasized, and with a plea to develop both high fidelity as well as efficient, simplified methods for design.
Ferroelectric thin-film capacitors and piezoelectric switches for mobile communication applications.
Klee, Mareike; van Esch, Harry; Keur, Wilco; Kumar, Biju; van Leuken-Peters, Linda; Liu, Jin; Mauczok, Rüdiger; Neumann, Kai; Reimann, Klaus; Renders, Christel; Roest, Aarnoud L; Tiggelman, Mark P J; de Wild, Marco; Wunnicke, Olaf; Zhao, Jing
2009-08-01
Thin-film ferroelectric capacitors have been integrated with resistors and active functions such as ESD protection into small, miniaturized modules, which enable a board space saving of up to 80%. With the optimum materials and processes, integrated capacitors with capacitance densities of up to 100 nF/mm2 for stacked capacitors combined with breakdown voltages of 90 V have been achieved. The integration of these high-density capacitors with extremely high breakdown voltage is a major accomplishment in the world of passive components and has not yet been reported for any other passive integration technology. Furthermore, thin-film tunable capacitors based on barium strontium titanate with high tuning range and high quality factor at 1 GHz have been demonstrated. Finally, piezoelectric thin films for piezoelectric switches with high switching speed have been realized.
Use of Terrestrial Laser Scanning Technology for Long Term High Precision Deformation Monitoring
Vezočnik, Rok; Ambrožič, Tomaž; Sterle, Oskar; Bilban, Gregor; Pfeifer, Norbert; Stopar, Bojan
2009-01-01
The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable. PMID:22303152
Advantages of Integrative Data Analysis for Developmental Research
ERIC Educational Resources Information Center
Bainter, Sierra A.; Curran, Patrick J.
2015-01-01
Amid recent progress in cognitive development research, high-quality data resources are accumulating, and data sharing and secondary data analysis are becoming increasingly valuable tools. Integrative data analysis (IDA) is an exciting analytical framework that can enhance secondary data analysis in powerful ways. IDA pools item-level data across…
NASA Technical Reports Server (NTRS)
McElwain, Michael; Van Gorkom, Kyle; Bowers, Charles W.; Carnahan, Timothy M.; Kimble, Randy A.; Knight, J. Scott; Lightsey, Paul; Maghami, Peiman G.; Mustelier, David; Niedner, Malcolm B.;
2017-01-01
The James Webb Space Telescope (JWST) is a large (6.5 m) cryogenic segmented aperture telescope with science instruments that cover the near- and mid-infrared from 0.6-27 microns. The large aperture not only provides high photometric sensitivity, but it also enables high angular resolution across the bandpass, with a diffraction limited point spread function (PSF) at wavelengths longer than 2 microns. The JWST PSF quality and stability are intimately tied to the science capabilities as it is convolved with the astrophysical scene. However, the PSF evolves at a variety of timescales based on telescope jitter and thermal distortion as the observatory attitude is varied. We present the image quality and stability requirements, recent predictions from integrated modeling, measurements made during ground-based testing, and performance characterization activities that will be carried out as part of the commissioning process.
Ventegodt, Soren; Merrick, Joav; Andersen, Niels Jorgen
2003-01-01
Quality of life (QOL) means a good life and we believe that a good life is the same as living a life with a high quality. This paper presents the theoretical and philosophical framework of the Danish Quality of Life Survey, and of the SEQOL, QOL5, and QOL1 questionnaires.The notion of a good life can be observed from subjective to the objective, where this spectrum incorporates a number of existing quality of life theories. We call this spectrum the integrative quality-of-life (IQOL) theory and discuss the following aspects in this paper: well being, satisfaction with life, happiness, meaning in life, the biological information system (“balance”), realizing life potential, fulfillment of needs, and objective factors.The philosophy of life outlined in this paper tries to measure the global quality of life with questions derived from the integrative theory of the quality of life. The IQOL theory is an overall theory or meta-theory encompassing eight more factual theories in a subjective-existential-objective spectrum. Other philosophies of life can stress other aspects of life, but by this notion of introducing such an existential depth into the health and social sciences, we believe to have taken a necessary step towards a new humility and respect for the richness and complexity of life. PMID:14570993
Patterning two-dimensional chalcogenide crystals of Bi2Se3 and In2Se3 and efficient photodetectors
Zheng, Wenshan; Xie, Tian; Zhou, Yu; Chen, Y.L.; Jiang, Wei; Zhao, Shuli; Wu, Jinxiong; Jing, Yumei; Wu, Yue; Chen, Guanchu; Guo, Yunfan; Yin, Jianbo; Huang, Shaoyun; Xu, H.Q.; Liu, Zhongfan; Peng, Hailin
2015-01-01
Patterning of high-quality two-dimensional chalcogenide crystals with unique planar structures and various fascinating electronic properties offers great potential for batch fabrication and integration of electronic and optoelectronic devices. However, it remains a challenge that requires accurate control of the crystallization, thickness, position, orientation and layout. Here we develop a method that combines microintaglio printing with van der Waals epitaxy to efficiently pattern various single-crystal two-dimensional chalcogenides onto transparent insulating mica substrates. Using this approach, we have patterned large-area arrays of two-dimensional single-crystal Bi2Se3 topological insulator with a record high Hall mobility of ∼1,750 cm2 V−1 s−1 at room temperature. Furthermore, our patterned two-dimensional In2Se3 crystal arrays have been integrated and packaged to flexible photodetectors, yielding an ultrahigh external photoresponsivity of ∼1,650 A W−1 at 633 nm. The facile patterning, integration and packaging of high-quality two-dimensional chalcogenide crystals hold promise for innovations of next-generation photodetector arrays, wearable electronics and integrated optoelectronic circuits. PMID:25898022
Surface-Water Quality-Assurance Plan for the Tallahassee Office, U.S. Geological Survey
Tomlinson, Stewart A.
2006-01-01
This Tallahassee Office Surface-Water Quality-Assurance Plan documents the standards, policies, and procedures used by the Tallahassee Office for activities related to the collection, processing, storage, analysis, and publication of surface-water data. This plan serves as a guide to all Tallahassee Office personnel involved in surface-water data activities, and changes as the needs and requirements of the Tallahassee Office, Florida Integrated Science Center, and Water Discipline change. Reg-ular updates to this Plan represent an integral part of the quality-assurance process. In the Tallahassee Office, direct oversight and responsibility by the employee(s) assigned to a surface-water station, combined with team approaches in all work efforts, assure high-quality data, analyses, reviews, and reports for cooperating agencies and the public.
Mapping watershed integrity for the conterminous United States.
Thornbrugh, Darren J; Leibowitz, Scott G; Hill, Ryan A; Weber, Marc H; Johnson, Zachary C; Olsen, Anthony R; Flotemersch, Joseph E; Stoddard, John L; Peck, David V
2018-02-01
Watershed integrity is the capacity of a watershed to support and maintain the full range of ecological processes and functions essential to sustainability. Using information from EPA's StreamCat dataset, we calculated and mapped an Index of Watershed Integrity (IWI) for 2.6 million watersheds in the conterminous US with first-order approximations of relationships between stressors and six watershed functions: hydrologic regulation, regulation of water chemistry, sediment regulation, hydrologic connectivity, temperature regulation, and habitat provision. Results show high integrity in the western US, intermediate integrity in the southern and eastern US, and the lowest integrity in the temperate plains and lower Mississippi Valley. Correlation between the six functional components was high ( r = 0.85-0.98). A related Index of Catchment Integrity (ICI) was developed using local drainages of individual stream segments (i.e., excluding upstream information). We evaluated the ability of the IWI and ICI to predict six continuous site-level indicators with regression analyses - three biological indicators and principal components derived from water quality, habitat, and combined water quality and habitat variables - using data from EPA's National Rivers and Streams Assessment. Relationships were highly significant, but the IWI only accounted for 1-12% of the variation in the four biological and habitat variables. The IWI accounted for over 25% of the variation in the water quality and combined principal components nationally, and 32-39% in the Northern and Southern Appalachians. We also used multinomial logistic regression to compare the IWI with the categorical forms of the three biological indicators. Results were consistent: we found positive associations but modest results. We compared how the IWI and ICI predicted the water quality PC relative to agricultural and urban land use. The IWI or ICI are the best predictors of the water quality PC for the CONUS and six of the nine ecoregions, but they only perform marginally better than agriculture in most instances. However, results suggest that agriculture would not be appropriate in all parts of the country, and the index is meant to be responsive to all stressors. The IWI in its present form (available through the StreamCat website; https://www.epa.gov/national-aquatic-resource-surveys/streamcat) could be useful for management efforts at multiple scales, especially when combined with information on site condition. The IWI could be improved by incorporating empirical or literature-derived relationships between functional components and stressors. However, limitations concerning the absence of data for certain stressors should be considered.
Net-Based Training for Physicians
ERIC Educational Resources Information Center
Jokela, Paivi; Karlsudd, Peter
2009-01-01
In order to ensure and increase access to high-quality learning opportunities it is becoming more and more common to integrate e-learning into health-related environments. The rapid development of these new learning environments also requires continuous monitoring and evaluation, to guarantee the quality of the health-care education. In this…
Obure, Carol Dayo; Jacobs, Rowena; Guinness, Lorna; Mayhew, Susannah; Vassall, Anna
2016-01-01
Theoretically, integration of vertically organized services is seen as an important approach to improving the efficiency of health service delivery. However, there is a dearth of evidence on the effect of integration on the technical efficiency of health service delivery. Furthermore, where technical efficiency has been assessed, there have been few attempts to incorporate quality measures within efficiency measurement models particularly in sub-Saharan African settings. This paper investigates the technical efficiency and the determinants of technical efficiency of integrated HIV and sexual and reproductive health (SRH) services using data collected from 40 health facilities in Kenya and Swaziland for 2008/2009 and 2010/2011. Incorporating a measure of quality, we estimate the technical efficiency of health facilities and explore the effect of integration and other environmental factors on technical efficiency using a two-stage semi-parametric double bootstrap approach. The empirical results reveal a high degree of inefficiency in the health facilities studied. The mean bias corrected technical efficiency scores taking quality into consideration varied between 22% and 65% depending on the data envelopment analysis (DEA) model specification. The number of additional HIV services in the maternal and child health unit, public ownership and facility type, have a positive and significant effect on technical efficiency. However, number of additional HIV and STI services provided in the same clinical room, proportion of clinical staff to overall staff, proportion of HIV services provided, and rural location had a negative and significant effect on technical efficiency. The low estimates of technical efficiency and mixed effects of the measures of integration on efficiency challenge the notion that integration of HIV and SRH services may substantially improve the technical efficiency of health facilities. The analysis of quality and efficiency as separate dimensions of performance suggest that efficiency may be achieved without sacrificing quality. PMID:26803655
Obure, Carol Dayo; Jacobs, Rowena; Guinness, Lorna; Mayhew, Susannah; Vassall, Anna
2016-02-01
Theoretically, integration of vertically organized services is seen as an important approach to improving the efficiency of health service delivery. However, there is a dearth of evidence on the effect of integration on the technical efficiency of health service delivery. Furthermore, where technical efficiency has been assessed, there have been few attempts to incorporate quality measures within efficiency measurement models particularly in sub-Saharan African settings. This paper investigates the technical efficiency and the determinants of technical efficiency of integrated HIV and sexual and reproductive health (SRH) services using data collected from 40 health facilities in Kenya and Swaziland for 2008/2009 and 2010/2011. Incorporating a measure of quality, we estimate the technical efficiency of health facilities and explore the effect of integration and other environmental factors on technical efficiency using a two-stage semi-parametric double bootstrap approach. The empirical results reveal a high degree of inefficiency in the health facilities studied. The mean bias corrected technical efficiency scores taking quality into consideration varied between 22% and 65% depending on the data envelopment analysis (DEA) model specification. The number of additional HIV services in the maternal and child health unit, public ownership and facility type, have a positive and significant effect on technical efficiency. However, number of additional HIV and STI services provided in the same clinical room, proportion of clinical staff to overall staff, proportion of HIV services provided, and rural location had a negative and significant effect on technical efficiency. The low estimates of technical efficiency and mixed effects of the measures of integration on efficiency challenge the notion that integration of HIV and SRH services may substantially improve the technical efficiency of health facilities. The analysis of quality and efficiency as separate dimensions of performance suggest that efficiency may be achieved without sacrificing quality. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
A Fast and Scalable Radiation Hybrid Map Construction and Integration Strategy
Agarwala, Richa; Applegate, David L.; Maglott, Donna; Schuler, Gregory D.; Schäffer, Alejandro A.
2000-01-01
This paper describes a fast and scalable strategy for constructing a radiation hybrid (RH) map from data on different RH panels. The maps on each panel are then integrated to produce a single RH map for the genome. Recurring problems in using maps from several sources are that the maps use different markers, the maps do not place the overlapping markers in same order, and the objective functions for map quality are incomparable. We use methods from combinatorial optimization to develop a strategy that addresses these issues. We show that by the standard objective functions of obligate chromosome breaks and maximum likelihood, software for the traveling salesman problem produces RH maps with better quality much more quickly than using software specifically tailored for RH mapping. We use known algorithms for the longest common subsequence problem as part of our map integration strategy. We demonstrate our methods by reconstructing and integrating maps for markers typed on the Genebridge 4 (GB4) and the Stanford G3 panels publicly available from the RH database. We compare map quality of our integrated map with published maps for GB4 panel and G3 panel by considering whether markers occur in the same order on a map and in DNA sequence contigs submitted to GenBank. We find that all of the maps are inconsistent with the sequence data for at least 50% of the contigs, but our integrated maps are more consistent. The map integration strategy not only scales to multiple RH maps but also to any maps that have comparable criteria for measuring map quality. Our software improves on current technology for doing RH mapping in areas of computation time and algorithms for considering a large number of markers for mapping. The essential impediments to producing dense high-quality RH maps are data quality and panel size, not computation. PMID:10720576
Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert
2017-01-01
In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80–100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes. PMID:28145513
High-quality weather data for grid integration studies
NASA Astrophysics Data System (ADS)
Draxl, C.
2016-12-01
As variable renewable power penetration levels increase in power systems worldwide, renewable integration studies are crucial to ensure continued economic and reliable operation of the power grid. In this talk we will shed light on requirements for grid integration studies as far as wind and solar energy are concerned. Because wind and solar plants are strongly impacted by weather, high-resolution and high-quality weather data are required to drive power system simulations. Future data sets will have to push limits of numerical weather prediction to yield these high-resolution data sets, and wind data will have to be time-synchronized with solar data. Current wind and solar integration data sets will be presented. The Wind Integration National Dataset (WIND) Toolkit is the largest and most complete grid integration data set publicly available to date. A meteorological data set, wind power production time series, and simulated forecasts created using the Weather Research and Forecasting Model run on a 2-km grid over the continental United States at a 5-min resolution is now publicly available for more than 126,000 land-based and offshore wind power production sites. The Solar Integration National Dataset (SIND) is available as time synchronized with the WIND Toolkit, and will allow for combined wind-solar grid integration studies. The National Solar Radiation Database (NSRDB) is a similar high temporal- and spatial resolution database of 18 years of solar resource data for North America and India. Grid integration studies are also carried out in various countries, which aim at increasing their wind and solar penetration through combined wind and solar integration data sets. We will present a multi-year effort to directly support India's 24x7 energy access goal through a suite of activities aimed at enabling large-scale deployment of clean energy and energy efficiency. Another current effort is the North-American-Renewable-Integration-Study, with the aim of providing a seamless data set across borders for a whole continent, to simulate and analyze the impacts of potential future large wind and solar power penetrations on bulk power system operations.
Industrial pollution and the management of river water quality: a model of Kelani River, Sri Lanka.
Gunawardena, Asha; Wijeratne, E M S; White, Ben; Hailu, Atakelty; Pandit, Ram
2017-08-19
Water quality of the Kelani River has become a critical issue in Sri Lanka due to the high cost of maintaining drinking water standards and the market and non-market costs of deteriorating river ecosystem services. By integrating a catchment model with a river model of water quality, we developed a method to estimate the effect of pollution sources on ambient water quality. Using integrated model simulations, we estimate (1) the relative contribution from point (industrial and domestic) and non-point sources (river catchment) to river water quality and (2) pollutant transfer coefficients for zones along the lower section of the river. Transfer coefficients provide the basis for policy analyses in relation to the location of new industries and the setting of priorities for industrial pollution control. They also offer valuable information to design socially optimal economic policy to manage industrialized river catchments.
McEvoy, Phil; Escott, Diane; Bee, Penny
2011-01-01
This study is based on a formative evaluation of a case management service for high-intensity service users in Northern England. The evaluation had three main purposes: (i) to assess the quality of the organisational infrastructure; (ii) to obtain a better understanding of the key influences that played a role in shaping the development of the service; and (iii) to identify potential changes in practice that may help to improve the quality of service provision. The evaluation was informed by Gittell's relational co-ordination theory, which focuses upon cross-boundary working practices that facilitate task integration. The Assessment of Chronic Illness Care Survey was used to assess the organisational infrastructure and qualitative interviews with front line staff were conducted to explore the key influences that shaped the development of the service. A high level of strategic commitment and political support for integrated working was identified. However, the quality of care co-ordination was variable. The most prominent operational factor that appeared to influence the scope and quality of care co-ordination was the pattern of interaction between the case managers and their co-workers. The co-ordination of patient care was much more effective in integrated co-ordination networks. Key features included clearly defined, task focussed, relational workspaces with interactive forums where case managers could engage with co-workers in discussions about the management of interdependent care activities. In dispersed co-ordination networks with fewer relational workspaces, the case managers struggled to work as effectively. The evaluation concluded that the creation of flexible and efficient task focused relational workspaces that are systemically managed and adequately resourced could help to improve the quality of care co-ordination, particularly in dispersed networks. © 2010 Blackwell Publishing Ltd.
Stalder, Aurelien F; Schmidt, Michaela; Quick, Harald H; Schlamann, Marc; Maderwald, Stefan; Schmitt, Peter; Wang, Qiu; Nadar, Mariappan S; Zenge, Michael O
2015-12-01
To integrate, optimize, and evaluate a three-dimensional (3D) contrast-enhanced sparse MRA technique with iterative reconstruction on a standard clinical MR system. Data were acquired using a highly undersampled Cartesian spiral phyllotaxis sampling pattern and reconstructed directly on the MR system with an iterative SENSE technique. Undersampling, regularization, and number of iterations of the reconstruction were optimized and validated based on phantom experiments and patient data. Sparse MRA of the whole head (field of view: 265 × 232 × 179 mm(3) ) was investigated in 10 patient examinations. High-quality images with 30-fold undersampling, resulting in 0.7 mm isotropic resolution within 10 s acquisition, were obtained. After optimization of the regularization factor and of the number of iterations of the reconstruction, it was possible to reconstruct images with excellent quality within six minutes per 3D volume. Initial results of sparse contrast-enhanced MRA (CEMRA) in 10 patients demonstrated high-quality whole-head first-pass MRA for both the arterial and venous contrast phases. While sparse MRI techniques have not yet reached clinical routine, this study demonstrates the technical feasibility of high-quality sparse CEMRA of the whole head in a clinical setting. Sparse CEMRA has the potential to become a viable alternative where conventional CEMRA is too slow or does not provide sufficient spatial resolution. © 2014 Wiley Periodicals, Inc.
In-process fault detection for textile fabric production: onloom imaging
NASA Astrophysics Data System (ADS)
Neumann, Florian; Holtermann, Timm; Schneider, Dorian; Kulczycki, Ashley; Gries, Thomas; Aach, Til
2011-05-01
Constant and traceable high fabric quality is of high importance both for technical and for high-quality conventional fabrics. Usually, quality inspection is carried out by trained personal, whose detection rate and maximum period of concentration are limited. Low resolution automated fabric inspection machines using texture analysis were developed. Since 2003, systems for the in-process inspection on weaving machines ("onloom") are commercially available. With these defects can be detected, but not measured quantitative precisely. Most systems are also prone to inevitable machine vibrations. Feedback loops for fault prevention are not established. Technology has evolved since 2003: Camera and computer prices dropped, resolutions were enhanced, recording speeds increased. These are the preconditions for real-time processing of high-resolution images. So far, these new technological achievements are not used in textile fabric production. For efficient use, a measurement system must be integrated into the weaving process; new algorithms for defect detection and measurement must be developed. The goal of the joint project is the development of a modern machine vision system for nondestructive onloom fabric inspection. The system consists of a vibration-resistant machine integration, a high-resolution machine vision system, and new, reliable, and robust algorithms with quality database for defect documentation. The system is meant to detect, measure, and classify at least 80 % of economically relevant defects. Concepts for feedback loops into the weaving process will be pointed out.
1984-03-01
Engineering initiative to develop an orderly plan and procedure to assure that USAF acquire reliable, high quality, supportable avionics with a higher avail...susceptibility te~t~ (radiated and conducted), and emission of radio frequency energy tests."l6) Other electrical stresses can include over/under voltage...jo ints, poor welds, and dielectric defects. Also, instruments with components unable to endu very high temperatures can be safely tested. 1-19
NASA Astrophysics Data System (ADS)
Liu, Wentao; Liu, Zhanqiang
2018-03-01
Machinability improvement of titanium alloy Ti-6Al-4V is a challenging work in academic and industrial applications owing to its low thermal conductivity, low elasticity modulus and high chemical affinity at high temperatures. Surface integrity of titanium alloys Ti-6Al-4V is prominent in estimating the quality of machined components. The surface topography (surface defects and surface roughness) and the residual stress induced by machining Ti-6Al-4V occupy pivotal roles for the sustainability of Ti-6Al-4V components. High-pressure coolant (HPC) is a potential choice in meeting the requirements for the manufacture and application of Ti-6Al-4V. This paper reviews the progress towards the improvements of Ti-6Al4V surface integrity under HPC. Various researches of surface integrity characteristics have been reported. In particularly, surface roughness, surface defects, residual stress as well as work hardening are investigated in order to evaluate the machined surface qualities. Several coolant parameters (including coolant type, coolant pressure and the injection position) deserve investigating to provide the guidance for a satisfied machined surface. The review also provides a clear roadmap for applications of HPC in machining Ti-6Al4V. Experimental studies and analysis are reviewed to better understand the surface integrity under HPC machining process. A distinct discussion has been presented regarding the limitations and highlights of the prospective for machining Ti-6Al4V under HPC.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-17
... DEPARTMENT OF EDUCATION National Advisory Committee on Institutional Quality and Integrity (NACIQI) Teleconference AGENCY: National Advisory Committee on Institutional Quality and Integrity, Office of... teleconference meeting of the National Advisory Committee on Institutional Quality and Integrity (NACIQI) and...
ERIC Educational Resources Information Center
Smith, Calvin; Worsfold, Kate
2015-01-01
This paper describes the impacts of work-integrated learning (WIL) curriculum components on general employability skills--professional work-readiness, self-efficacy and team skills. Regression analyses emphasise the importance of the "authenticity" of WIL placements for the development of these generic outcomes. Other curricula factors…
ERIC Educational Resources Information Center
Mangione, Peter L.; Lally, J. Ronald; Poole, Janet L.; Tuesta, Alicia; Paxton, Arlene R.
2011-01-01
States have placed high priority on developing early care and education systems that include early learning guidelines, curriculum, program guidelines or standards, and early childhood educator competencies. To explore how professional development and quality improvement initiatives are being integrated into emerging infant-toddler care systems,…
The Effect of Social Integration on Outcomes after Major Lower Extremity Amputation
Hawkins, Alexander T.; Pallangyo, Anthony J.; Herman, Ayesiga M.; Schaumeier, Maria J.; Smith, Ann D.; Hevelone, Nathanael D.; Crandell, David M.; Nguyen, Louis
2016-01-01
Objective Major lower extremity amputation is a common procedure that results in a profound change in a patient's life. We sought to determine the association between social support and outcomes after amputation. We hypothesized that patients with greater social support will have better post amputation outcomes. Methods From November 2011 to May 2013, we conducted a cross-sectional, observational, multicenter study. Social integration was measured by the social integration subset of the Short Form (Craig Handicap Assessment and Reporting Technique (CHART). Systemic social support was assessed by comparing a US and Tanzanian population. Walking function was measured using the 6MWT and quality of life (QoL) was measured using the EQ-5D. Results 102 major lower extremity amputees were recruited. 63 patients were enrolled in the US with a mean age of 58.0. Forty-two (67%) were male. Patients with low social integration were more likely to be unable to ambulate (no walk 39% vs. slow walk 23% vs. fast walk 10%; P=.01) and those with high social integration were more likely to be fast walkers (no walk 10% vs. slow walk 59% vs. fast walk 74%; P=.01). This relationship persisted in a multivariable analysis. Increasing social integration scores were also positively associated with increasing quality of life scores in a multivariable analysis (β .002; SE .0008; P = .02). In comparing the US population with the Tanzanian cohort (39 subjects), there were no significant differences between functional or quality of life outcomes in the systemic social support analysis. Conclusions In the US population, increased social integration is associated with both improved function and quality of life outcomes among major lower extremity amputees. Systemic social support, as measured by comparing the US population with a Tanzanian population, was not associated with improved function or quality of life outcomes. In the US, steps should be taken to identify and aid amputees with poor social integration. PMID:26474508
Si-Based Germanium Tin Semiconductor Lasers for Optoelectronic Applications
NASA Astrophysics Data System (ADS)
Al-Kabi, Sattar H. Sweilim
Silicon-based materials and optoelectronic devices are of great interest as they could be monolithically integrated in the current Si complementary metal-oxide-semiconductor (CMOS) processes. The integration of optoelectronic components on the CMOS platform has long been limited due to the unavailability of Si-based laser sources. A Si-based monolithic laser is highly desirable for full integration of Si photonics chip. In this work, Si-based germanium-tin (GeSn) lasers have been demonstrated as direct bandgap group-IV laser sources. This opens a completely new avenue from the traditional III-V integration approach. In this work, the material and optical properties of GeSn alloys were comprehensively studied. The GeSn films were grown on Ge-buffered Si substrates in a reduced pressure chemical vapor deposition system with low-cost SnCl4 and GeH4 precursors. A systematic study was done for thin GeSn films (thickness 400 nm) with Sn composition 5 to 17.5%. The room temperature photoluminescence (PL) spectra were measured that showed a gradual shift of emission peaks towards longer wavelength as Sn composition increases. Strong PL intensity and low defect density indicated high material quality. Moreover, the PL study of n-doped samples showed bandgap narrowing compared to the unintentionally p-doped (boron) thin films with similar Sn compositions. Finally, optically pumped GeSn lasers on Si with broad wavelength coverage from 2 to 3 mum were demonstrated using high-quality GeSn films with Sn compositions up to 17.5%. The achieved maximum Sn composition of 17.5% broke the acknowledged Sn incorporation limit using similar deposition chemistry. The highest lasing temperature was measured at 180 K with an active layer thickness as thin as 270 nm. The unprecedented lasing performance is due to the achievement of high material quality and a robust fabrication process. The results reported in this work show a major advancement towards Si-based electrically pumped mid-infrared laser sources for integrated photonics.
Rata, Mihaela; Birlea, Vlad; Murillo, Adriana; Paquet, Christian; Cotton, François; Salomir, Rares
2015-01-01
MR-guided high-intensity contact ultrasound (HICU) was suggested as an alternative therapy for esophageal and rectal cancer. To offer high-quality MR guidance, two prototypes of receive-only opposed-solenoid coil were integrated with 64-element cylindrical phased-array ultrasound transducers (rectal/esophageal). The design of integrated coils took into account the transducer geometry (360° acoustic window within endoluminal space). The rectal coil was sealed on a plastic support and placed reversibly on the transducer head. The esophageal coil was fully embedded within the transducer head, resulting in one indivisible device. Comparison of integrated versus external coils was performed on a clinical 1.5T scanner. The integrated coils showed higher sensitivity compared with the standard extracorporeal coil with factors of up to 7.5 (rectal applicator) and 3.3 (esophageal applicator). High-resolution MR images for both anatomy (voxel 0.4 × 0.4 × 5 mm(3)) and thermometry (voxel 0.75 × 0.75 × 8 mm(3), 2 s/image) were acquired in vivo with the rectal endoscopic device. The temperature feedback loop accurately controlled multiple control points over the region of interest. This study showed significant improvement of MR data quality using endoluminal integrated coils versus standard external coil. Inframillimeter spatial resolution and accurate feedback control of MR-guided HICU thermotherapy were achieved. © 2014 Wiley Periodicals, Inc.
While the spatial heterogeneity of many aquatic ecosystems is acknowledged, rivers are often mistakenly described as homogenous and well-mixed. The collection and visualization of attributes like water quality is key to our perception and management of these ecosystems. The ass...
ERIC Educational Resources Information Center
Dixon, John; Girifalco, Tony; Yakabosky, Walt
2008-01-01
This article describes the Applied Engineering Technology (AET) Career and Educational Pathways Program, which helps local manufacturers find quality workers. The program features 32 high schools, three community colleges, and 10 four-year institutions offering an integrated regional system of applied engineering education. The goal is to enroll…
Guaranteeing the quality and integrity of pork - An Australian case study.
Channon, H A; D'Souza, D N; Jarrett, R G; Lee, G S H; Watling, R J; Jolley, J Y C; Dunshea, F R
2018-04-27
The Australian pork industry is strongly committed to assuring the integrity of its product, with substantial research investment made over the past ten years to develop and implement systems to assure the consistency and quality of fresh pork and to enable accurate tracing of unpackaged fresh pork back to property of origin using trace elemental profiling. These initiatives are pivotal to allow Australian pork of guaranteed eating quality to be successfully positioned as higher value products, across a range of international and domestic markets, whilst managing any threats of product substitution. This paper describes the current status of the development of a predictive eating quality model for Australian pork, utilizing eating quality datasets generated from recent Australian studies. The implementation of trace elemental profiling, by Physi-Trace™, to verify and defend provenance claims and support the supply of consistently high eating quality Australian pork to its customers, is also discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ultra-high-throughput Production of III-V/Si Wafer for Electronic and Photonic Applications
Geum, Dae-Myeong; Park, Min-Su; Lim, Ju Young; Yang, Hyun-Duk; Song, Jin Dong; Kim, Chang Zoo; Yoon, Euijoon; Kim, SangHyeon; Choi, Won Jun
2016-01-01
Si-based integrated circuits have been intensively developed over the past several decades through ultimate device scaling. However, the Si technology has reached the physical limitations of the scaling. These limitations have fuelled the search for alternative active materials (for transistors) and the introduction of optical interconnects (called “Si photonics”). A series of attempts to circumvent the Si technology limits are based on the use of III-V compound semiconductor due to their superior benefits, such as high electron mobility and direct bandgap. To use their physical properties on a Si platform, the formation of high-quality III-V films on the Si (III-V/Si) is the basic technology ; however, implementing this technology using a high-throughput process is not easy. Here, we report new concepts for an ultra-high-throughput heterogeneous integration of high-quality III-V films on the Si using the wafer bonding and epitaxial lift off (ELO) technique. We describe the ultra-fast ELO and also the re-use of the III-V donor wafer after III-V/Si formation. These approaches provide an ultra-high-throughput fabrication of III-V/Si substrates with a high-quality film, which leads to a dramatic cost reduction. As proof-of-concept devices, this paper demonstrates GaAs-based high electron mobility transistors (HEMTs), solar cells, and hetero-junction phototransistors on Si substrates. PMID:26864968
Effects of radiation quality, intensity, and duration on photosynthesis and growth
NASA Technical Reports Server (NTRS)
Bugbee, Bruce
1994-01-01
Differences in radiation quality from the six most common electric lamps have little effect on photosynthetic rate. Radiation quality primarily alters growth because of changes in branching or internode elongation, which change radiation absorption. Growth and yield in wheat appear to be insensitive to radiation quality. Growth and yield in soybeans can be slightly increased under high pressure sodium (HPS) lamps compared to metal halide lamps, in spite of greatly reduced chlorophyll concentrations under HPS lamps. Daily integrated photosynthetic photon flux (mol m(exp -2)d(exp -1)) most directly determines leaf anatomy and growth. Photosynthetic photon flux (PPF) levels of 800 (mu)mol m(exp -2)s(exp -1) are adequate to simulate field daily-integrated PPF levels for both short and long day plants, but plant canopies can benefit from much higher PPF levels.
Effects of radiation quality, intensity, and duration on photosynthesis and growth
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bugbee, B.
1994-12-31
Differences in radiation quality from the six most common electric lamps have little effect on photosynthetic rate. Radiation quality primarily alters growth because of changes in branching or internode elongation, which change radiation absorption. Growth and yield in wheat appear to be insensitive to radiation quality. Growth and yield in soybeans can be slightly increased under high pressure sodium lamps compared to metal halide lamps, in spite of greatly reduced chlorophyll concentrations under HPS lamps. Daily integrated photosynthetic photon flux (mol m{sup -2} d{sup -1}) most directly determines leaf anatomy and growth. Photosynthetic photon flux levels of 800 {mu}mol m{supmore » -2} s{sup -1} are adequate to simulate field daily-integrated PPF levels for both short and long day plants, but plant canopies can benefit from much higher PPF levels.« less
Gonzalez, Maria E; Anthon, Gordon E; Barrett, Diane M
2010-09-01
Two different analytical methods were evaluated for their capacity to provide quantitative information on onion cell membrane permeability and integrity after high pressure and thermal processing and to study the impact of these processing treatments on cell compartmentalization and texture quality. To determine changes in cell membrane permeability and/or integrity the methodologies utilized were: (1) measurement of a biochemical product, pyruvate, formed as a result of membrane permeabilization followed by enzymatic activity and (2) leakage of electrolytes into solution. These results were compared to previously determined methods that quantified cell viability and ¹H-NMR T(2) of onions. These methods allowed for the monitoring of changes in the plasma and tonoplast membranes after high pressure or thermal processing. High pressure treatments consisted of 5 min holding times at 50, 100, 200, 300, or 600 MPa. Thermal treatments consisted of 30 min water bath exposure to 40, 50, 60, 70, or 90 °C. There was strong agreement between the methods in the determination of the ranges of high pressure and temperature that induce changes in the integrity of the plasma and tonoplast membranes. Membrane rupture could clearly be identified at 300 MPa and above in high pressure treatments and at 60 °C and above in the thermal treatments. Membrane destabilization effects could already be visualized following the 200 MPa and 50 °C treatments. The texture of onions was influenced by the state of the membranes and was abruptly modified once membrane integrity was lost. In this study, we used chemical, biochemical, and histological techniques to obtain information on cell membrane permeability and onion tissue integrity after high pressure and thermal processing. Because there was strong agreement between the various methods used, it is possible to implement something relatively simple, such as ion leakage, into routine quality assurance measurements to determine the severity of preservation methods and the shelf life of processed vegetables.
Oriented modulation for watermarking in direct binary search halftone images.
Guo, Jing-Ming; Su, Chang-Cheng; Liu, Yun-Fu; Lee, Hua; Lee, Jiann-Der
2012-09-01
In this paper, a halftoning-based watermarking method is presented. This method enables high pixel-depth watermark embedding, while maintaining high image quality. This technique is capable of embedding watermarks with pixel depths up to 3 bits without causing prominent degradation to the image quality. To achieve high image quality, the parallel oriented high-efficient direct binary search (DBS) halftoning is selected to be integrated with the proposed orientation modulation (OM) method. The OM method utilizes different halftone texture orientations to carry different watermark data. In the decoder, the least-mean-square-trained filters are applied for feature extraction from watermarked images in the frequency domain, and the naïve Bayes classifier is used to analyze the extracted features and ultimately to decode the watermark data. Experimental results show that the DBS-based OM encoding method maintains a high degree of image quality and realizes the processing efficiency and robustness to be adapted in printing applications.
Provider perceptions of an integrated primary care quality improvement strategy: The PPAQ toolkit.
Beehler, Gregory P; Lilienthal, Kaitlin R
2017-02-01
The Primary Care Behavioral Health (PCBH) model of integrated primary care is challenging to implement with high fidelity. The Primary Care Behavioral Health Provider Adherence Questionnaire (PPAQ) was designed to assess provider adherence to essential model components and has recently been adapted into a quality improvement toolkit. The aim of this pilot project was to gather preliminary feedback on providers' perceptions of the acceptability and utility of the PPAQ toolkit for making beneficial practice changes. Twelve mental health providers working in Department of Veterans Affairs integrated primary care clinics participated in semistructured interviews to gather quantitative and qualitative data. Descriptive statistics and qualitative content analysis were used to analyze data. Providers identified several positive features of the PPAQ toolkit organization and structure that resulted in high ratings of acceptability, while also identifying several toolkit components in need of modification to improve usability. Toolkit content was considered highly representative of the (PCBH) model and therefore could be used as a diagnostic self-assessment of model adherence. The toolkit was considered to be high in applicability to providers regardless of their degree of prior professional preparation or current clinical setting. Additionally, providers identified several system-level contextual factors that could impact the usefulness of the toolkit. These findings suggest that frontline mental health providers working in (PCBH) settings may be receptive to using an adherence-focused toolkit for ongoing quality improvement. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Customer and household matching: resolving entity identity in data warehouses
NASA Astrophysics Data System (ADS)
Berndt, Donald J.; Satterfield, Ronald K.
2000-04-01
The data preparation and cleansing tasks necessary to ensure high quality data are among the most difficult challenges faced in data warehousing and data mining projects. The extraction of source data, transformation into new forms, and loading into a data warehouse environment are all time consuming tasks that can be supported by methodologies and tools. This paper focuses on the problem of record linkage or entity matching, tasks that can be very important in providing high quality data. Merging two or more large databases into a single integrated system is a difficult problem in many industries, especially in the wake of acquisitions. For example, managing customer lists can be challenging when duplicate entries, data entry problems, and changing information conspire to make data quality an elusive target. Common tasks with regard to customer lists include customer matching to reduce duplicate entries and household matching to group customers. These often O(n2) problems can consume significant resources, both in computing infrastructure and human oversight, and the goal of high accuracy in the final integrated database can be difficult to assure. This paper distinguishes between attribute corruption and entity corruption, discussing the various impacts on quality. A metajoin operator is proposed and used to organize past and current entity matching techniques. Finally, a logistic regression approach to implementing the metajoin operator is discussed and illustrated with an example. The metajoin can be used to determine whether two records match, don't match, or require further evaluation by human experts. Properly implemented, the metajoin operator could allow the integration of individual databases with greater accuracy and lower cost.
Authentic Leadership: Practices to Promote Integrity.
Hughes, Vickie
Integrity is a highly desired leadership trait. Authentic leaders reflect on their behavior and seek feedback about how their actions affect others. How can a nurse develop as an authentic leader who consistently demonstrates integrity? The following are discussed: Reflection; Connection to Christ and others; Social and Emotional Intelligence providing perceptive competency and social awareness; Aesthetic Qualities whereby leaders apply experiential knowing in leadership situations; and effective expression of Gratitude as a meaningful act of valuing others.
High Tech Training at Arthur Andersen and Co.
ERIC Educational Resources Information Center
Dennis, Verl E.
1984-01-01
Discusses Arthur Andersen and Company's reasons for using high technology in job training, including its ability to improve productivity, provide training on demand, reduce training costs, and keep educational quality consistent. A Life Cycle Model which is used to integrate high technology into this accounting company's educational programs is…
Ritchie, Linda; Wright-St Clair, Valerie A; Keogh, Justin; Gray, Marion
2014-01-01
To explore the scope, reliability, and validity of community integration measures for older adults after traumatic brain injury (TBI). A search of peer-reviewed articles in English from 1990 to April 2011 was conducted using the EBSCO Health and Scopus databases. Search terms included were community integration, traumatic brain injury or TBI, 65 plus or older adults, and assessment. Forty-three eligible articles were identified, with 11 selected for full review using a standardized critical review method. Common community integration measures were identified and ranked for relevance and psychometric properties. Of the 43 eligible articles, studies reporting community integration outcomes post-TBI were identified and critically reviewed. Older adults' community integration needs post-TBI from high quality studies were summarized. There is a relative lack of evidence pertaining to older adults post-TBI, but indicators are that older adults have poorer outcomes than their younger counterparts. The Community Integration Questionnaire (CIQ) is the most widely used community integration measurement tool used in research for people with TBI. Because of some limitations, many studies have used the CIQ in conjunction with other measures to better quantify and/or monitor changes in community integration. Enhancing integration of older adults after TBI into their community of choice, with particular emphasis on social integration and quality of life, should be a primary rehabilitation goal. However, more research is needed to inform best practice guidelines to meet the needs of this growing TBI population. It is recommended that subjective tools, such as quality of life measures, are used in conjunction with well-established community integration measures, such as the CIQ, during the assessment process. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Quality user support: Supporting quality users
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woolley, T.C.
1994-12-31
During the past decade, fundamental changes have occurred in technical computing in the oil industry. Technical computing systems have moved from local, fragmented quantity, to global, integrated, quality. The compute power available to the average geoscientist at his desktop has grown exponentially. Technical computing applications have increased in integration and complexity. At the same time, there has been a significant change in the work force due to the pressures of restructuring, and the increased focus on international opportunities. The profile of the user of technical computing resources has changed. Users are generally more mature, knowledgeable, and team oriented than theirmore » predecessors. In the 1990s, computer literacy is a requirement. This paper describes the steps taken by Oryx Energy Company to address the problems and opportunities created by the explosive growth in computing power and needs, coupled with the contraction of the business. A successful user support strategy will be described. Characteristics of the program include: (1) Client driven support; (2) Empowerment of highly skilled professionals to fill the support role; (3) Routine and ongoing modification to the support plan; (4) Utilization of the support assignment to create highly trained advocates on the line; (5) Integration of the support role to the reservoir management team. Results of the plan include a highly trained work force, stakeholder teams that include support personnel, and global support from a centralized support organization.« less
A 3D image sensor with adaptable charge subtraction scheme for background light suppression
NASA Astrophysics Data System (ADS)
Shin, Jungsoon; Kang, Byongmin; Lee, Keechang; Kim, James D. K.
2013-02-01
We present a 3D ToF (Time-of-Flight) image sensor with adaptive charge subtraction scheme for background light suppression. The proposed sensor can alternately capture high resolution color image and high quality depth map in each frame. In depth-mode, the sensor requires enough integration time for accurate depth acquisition, but saturation will occur in high background light illumination. We propose to divide the integration time into N sub-integration times adaptively. In each sub-integration time, our sensor captures an image without saturation and subtracts the charge to prevent the pixel from the saturation. In addition, the subtraction results are cumulated N times obtaining a final result image without background illumination at full integration time. Experimental results with our own ToF sensor show high background suppression performance. We also propose in-pixel storage and column-level subtraction circuit for chiplevel implementation of the proposed method. We believe the proposed scheme will enable 3D sensors to be used in out-door environment.
Integrating Literature with Craft in a Learning Process with Creative Elements
ERIC Educational Resources Information Center
Aerila, Juli-Anna; Rönkkö, Marja-Leena
2015-01-01
Art-related learning should be the central way of doing and playing in preschool, because the high quality of art-related education has a positive effect on children's well-being, identity development, and creative thinking. In our study we tested an integrated learning process where reading literature and telling stories is combined with the…
1986-06-30
features of computer aided design systems and statistical quality control procedures that are generic to chip sets and processes. RADIATION HARDNESS -The...System PSP Programmable Signal Processor SSI Small Scale Integration ." TOW Tube Launched, Optically Tracked, Wire Guided TTL Transistor Transitor Logic
ERIC Educational Resources Information Center
Barres, David Griol; Carrion, Zoraida Callejas; Lopez-Cozar Delgado, Ramon
2013-01-01
By providing students with the opportunities to receive a high quality education regardless of their social or cultural background, inclusive education is a new area that goes beyond traditional integration approaches. These approaches hope to provide the educative system with the ability to adapt to the diversity of its students. Technologies for…
High Quality 3D Photonics using Nano Imprint Lithography of Fast Sol-gel Materials.
Bar-On, Ofer; Brenner, Philipp; Siegle, Tobias; Gvishi, Raz; Kalt, Heinz; Lemmer, Uli; Scheuer, Jacob
2018-05-18
A method for the realization of low-loss integrated optical components is proposed and demonstrated. This approach is simple, fast, inexpensive, scalable for mass production, and compatible with both 2D and 3D geometries. The process is based on a novel dual-step soft nano imprint lithography process for producing devices with smooth surfaces, combined with fast sol-gel technology providing highly transparent materials. As a concrete example, this approach is demonstrated on a micro ring resonator made by direct laser writing (DLW) to achieve a quality factor improvement from one hundred thousand to more than 3 million. To the best of our knowledge this also sets a Q-factor record for UV-curable integrated micro-ring resonators. The process supports the integration of many types of materials such as light-emitting, electro-optic, piezo-electric, and can be readily applied to a wide variety of devices such as waveguides, lenses, diffractive elements and more.
ERIC Educational Resources Information Center
Picus, Lawrence O.; Odden, Allan; Goetz, Michael
2009-01-01
This study estimates the costs of providing a high-quality PreK-3rd education approach in all 50 states plus the District of Columbia. Relying on an Evidence-Based approach to school finance adequacy, it identifies the staffing resources needed to offer high-quality integrated PreK-3rd programs and then estimates the costs of those resources. By…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lathrop, R.G. Jr.
1988-01-01
The utility of three operational satellite remote sensing systems, namely, the Landsat Thematic Mapper (TM), the SPOT High Resolution Visible (HRV) sensors and the NOAA Advanced Very High Resolution Radiometer (AVHRR), were evaluated as a means of estimating water quality and surface temperature. Empirical calibration through linear regression techniques was used to relate near-simultaneously acquired satellite radiance/reflectance data and water quality observations obtained in Green Bay and the nearshore waters of Lake Michigan. Four dates of TM and one date each of SPOT and AVHRR imagery/surface reference data were acquired and analyzed. Highly significant relationships were identified between the TMmore » and SPOT data and secchi disk depth, nephelometric turbidity, chlorophyll a, total suspended solids (TSS), absorbance, and surface temperature (TM only). The AVHRR data were not analyzed independently but were used for comparison with the TM data. Calibrated water quality image maps were input to a PC-based raster GIS package, EPPL7. Pattern interpretation and spatial analysis techniques were used to document the circulation dynamics and model mixing processes in Green Bay. A GIS facilitates the retrieval, query and spatial analysis of mapped information and provides the framework for an integrated operational monitoring system for the Great Lakes.« less
Off-Line Quality Control In Integrated Circuit Fabrication Using Experimental Design
NASA Astrophysics Data System (ADS)
Phadke, M. S.; Kackar, R. N.; Speeney, D. V.; Grieco, M. J.
1987-04-01
Off-line quality control is a systematic method of optimizing production processes and product designs. It is widely used in Japan to produce high quality products at low cost. The method was introduced to us by Professor Genichi Taguchi who is a Deming-award winner and a former Director of the Japanese Academy of Quality. In this paper we will i) describe the off-line quality control method, and ii) document our efforts to optimize the process for forming contact windows in 3.5 Aim CMOS circuits fabricated in the Murray Hill Integrated Circuit Design Capability Laboratory. In the fabrication of integrated circuits it is critically important to produce contact windows of size very near the target dimension. Windows which are too small or too large lead to loss of yield. The off-line quality control method has improved both the process quality and productivity. The variance of the window size has been reduced by a factor of four. Also, processing time for window photolithography has been substantially reduced. The key steps of off-line quality control are: i) Identify important manipulatable process factors and their potential working levels. ii) Perform fractional factorial experiments on the process using orthogonal array designs. iii) Analyze the resulting data to determine the optimum operating levels of the factors. Both the process mean and the process variance are considered in this analysis. iv) Conduct an additional experiment to verify that the new factor levels indeed give an improvement.
USING A FISH INDEX TO ASSESS HABITAT QUALITY IN NARRAGANSETT BAY, RHODE ISLAND
We developed an estuarine index of biotic integrity to assess habitat quality in Narragansett Bay, Rhode Island. Fish were collected at 18 fixed stations with a 61-m x 3.05-m beach seine once per month in July and August from 1988 to 1999. Stations were designated high or low qua...
High-frequency and high-quality silicon carbide optomechanical microresonators
Lu, Xiyuan; Lee, Jonathan Y.; Lin, Qiang
2015-01-01
Silicon carbide (SiC) exhibits excellent material properties attractive for broad applications. We demonstrate the first SiC optomechanical microresonators that integrate high mechanical frequency, high mechanical quality, and high optical quality into a single device. The radial-breathing mechanical mode has a mechanical frequency up to 1.69 GHz with a mechanical Q around 5500 in atmosphere, which corresponds to a fm · Qm product as high as 9.47 × 1012 Hz. The strong optomechanical coupling allows us to efficiently excite and probe the coherent mechanical oscillation by optical waves. The demonstrated devices, in combination with the superior thermal property, chemical inertness, and defect characteristics of SiC, show great potential for applications in metrology, sensing, and quantum photonics, particularly in harsh environments that are challenging for other device platforms. PMID:26585637
Bleach Gel: A Simple Agarose Gel for Analyzing RNA Quality
Aranda, Patrick S.; LaJoie, Dollie M.; Jorcyk, Cheryl L.
2013-01-01
RNA-based applications requiring high quality, non-degraded RNA are a foundational element of many research studies. As such, it is paramount that the integrity of experimental RNA is validated prior to cDNA synthesis or other downstream applications. In the absence of expensive equipment such as microfluidic electrophoretic devices, and as an alternative to the costly and time-consuming standard formaldehyde gel, RNA quality can be quickly analyzed by adding small amounts of commercial bleach to TAE buffer-based agarose gels prior to electrophoresis. In the presence of low concentrations of bleach, the secondary structure of RNA is denatured and potential contaminating RNases are destroyed. Because of this, the ‘bleach gel’ is a functional approach that addresses the need for an inexpensive and safe way to evaluate RNA integrity and will improve the ability of researchers to rapidly analyze RNA quality. PMID:22222980
NASA Astrophysics Data System (ADS)
Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang
2017-10-01
Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.
From Foucault to Freire Through Facebook: Toward an Integrated Theory of mHealth.
Bull, Sheana; Ezeanochie, Nnamdi
2016-08-01
To document the integration of social science theory in literature on mHealth (mobile health) and consider opportunities for integration of classic theory, health communication theory, and social networking to generate a relevant theory for mHealth program design. A secondary review of research syntheses and meta-analyses published between 2005 and 2014 related to mHealth, using the AMSTAR (A Measurement Tool to Assess Systematic Reviews) methodology for assessment of the quality of each review. High-quality articles from those reviews using a randomized controlled design and integrating social science theory in program design, implementation, or evaluation were reviewed. Results There were 1,749 articles among the 170 reviews with a high AMSTAR score (≥30). Only 13 were published from 2005 to 2014, used a randomized controlled design and made explicit mention of theory in any aspect of their mHealth program. All 13 included theoretical perspectives focused on psychological and/or psychosocial theories and constructs. Conclusions There is a very limited use of social science theory in mHealth despite demonstrated benefits in doing so. We propose an integrated theory of mHealth that incorporates classic theory, health communication theory, and social networking to guide development and evaluation of mHealth programs. © 2015 Society for Public Health Education.
Organic printed photonics: From microring lasers to integrated circuits
Zhang, Chuang; Zou, Chang-Ling; Zhao, Yan; Dong, Chun-Hua; Wei, Cong; Wang, Hanlin; Liu, Yunqi; Guo, Guang-Can; Yao, Jiannian; Zhao, Yong Sheng
2015-01-01
A photonic integrated circuit (PIC) is the optical analogy of an electronic loop in which photons are signal carriers with high transport speed and parallel processing capability. Besides the most frequently demonstrated silicon-based circuits, PICs require a variety of materials for light generation, processing, modulation, and detection. With their diversity and flexibility, organic molecular materials provide an alternative platform for photonics; however, the versatile fabrication of organic integrated circuits with the desired photonic performance remains a big challenge. The rapid development of flexible electronics has shown that a solution printing technique has considerable potential for the large-scale fabrication and integration of microsized/nanosized devices. We propose the idea of soft photonics and demonstrate the function-directed fabrication of high-quality organic photonic devices and circuits. We prepared size-tunable and reproducible polymer microring resonators on a wafer-scale transparent and flexible chip using a solution printing technique. The printed optical resonator showed a quality (Q) factor higher than 4 × 105, which is comparable to that of silicon-based resonators. The high material compatibility of this printed photonic chip enabled us to realize low-threshold microlasers by doping organic functional molecules into a typical photonic device. On an identical chip, this construction strategy allowed us to design a complex assembly of one-dimensional waveguide and resonator components for light signal filtering and optical storage toward the large-scale on-chip integration of microscopic photonic units. Thus, we have developed a scheme for soft photonic integration that may motivate further studies on organic photonic materials and devices. PMID:26601256
Organic printed photonics: From microring lasers to integrated circuits.
Zhang, Chuang; Zou, Chang-Ling; Zhao, Yan; Dong, Chun-Hua; Wei, Cong; Wang, Hanlin; Liu, Yunqi; Guo, Guang-Can; Yao, Jiannian; Zhao, Yong Sheng
2015-09-01
A photonic integrated circuit (PIC) is the optical analogy of an electronic loop in which photons are signal carriers with high transport speed and parallel processing capability. Besides the most frequently demonstrated silicon-based circuits, PICs require a variety of materials for light generation, processing, modulation, and detection. With their diversity and flexibility, organic molecular materials provide an alternative platform for photonics; however, the versatile fabrication of organic integrated circuits with the desired photonic performance remains a big challenge. The rapid development of flexible electronics has shown that a solution printing technique has considerable potential for the large-scale fabrication and integration of microsized/nanosized devices. We propose the idea of soft photonics and demonstrate the function-directed fabrication of high-quality organic photonic devices and circuits. We prepared size-tunable and reproducible polymer microring resonators on a wafer-scale transparent and flexible chip using a solution printing technique. The printed optical resonator showed a quality (Q) factor higher than 4 × 10(5), which is comparable to that of silicon-based resonators. The high material compatibility of this printed photonic chip enabled us to realize low-threshold microlasers by doping organic functional molecules into a typical photonic device. On an identical chip, this construction strategy allowed us to design a complex assembly of one-dimensional waveguide and resonator components for light signal filtering and optical storage toward the large-scale on-chip integration of microscopic photonic units. Thus, we have developed a scheme for soft photonic integration that may motivate further studies on organic photonic materials and devices.
Efficient high-performance ultrasound beamforming using oversampling
NASA Astrophysics Data System (ADS)
Freeman, Steven R.; Quick, Marshall K.; Morin, Marc A.; Anderson, R. C.; Desilets, Charles S.; Linnenbrink, Thomas E.; O'Donnell, Matthew
1998-05-01
High-performance and efficient beamforming circuitry is very important in large channel count clinical ultrasound systems. Current state-of-the-art digital systems using multi-bit analog to digital converters (A/Ds) have matured to provide exquisite image quality with moderate levels of integration. A simplified oversampling beamforming architecture has been proposed that may a low integration of delta-sigma A/Ds onto the same chip as digital delay and processing circuitry to form a monolithic ultrasound beamformer. Such a beamformer may enable low-power handheld scanners for high-end systems with very large channel count arrays. This paper presents an oversampling beamformer architecture that generates high-quality images using very simple; digitization, delay, and summing circuits. Additional performance may be obtained with this oversampled system for narrow bandwidth excitations by mixing the RF signal down in frequency to a range where the electronic signal to nose ratio of the delta-sigma A/D is optimized. An oversampled transmit beamformer uses the same delay circuits as receive and eliminates the need for separate transmit function generators.
AIRQino, a low-cost air quality mobile platform
NASA Astrophysics Data System (ADS)
Zaldei, Alessandro; Vagnoli, Carolina; Di Lonardo, Sara; Gioli, Beniamino; Gualtieri, Giovanni; Toscano, Piero; Martelli, Francesca; Matese, Alessandro
2015-04-01
Recent air quality regulations (Directive 2008/50/EC) enforce the transition from point-based monitoring networks to new tools that must be capable of mapping and forecasting air quality on the totality of land area, and therefore the totality of citizens. This implies new technologies such as models and additional indicative measurements, are needed in addition to accurate fixed air quality monitoring stations, that until now have been taken as reference by local administrators for the enforcement of various mitigation strategies. However, due to their sporadic spatial distribution, they cannot describe the highly resolved spatial pollutant variations within cities. Integrating additional indicative measurements may provide adequate information on the spatial distribution of the ambient air quality, also allowing for a reduction of the required minimum number of fixed sampling points, whose high cost and complex maintenance still remain a crucial concern for local administrators. New low-cost and small size sensors are becoming available, that could be employed in air quality monitoring including mobile applications. However, accurate assessment of their accuracy and performance both in controlled and real monitoring conditions is crucially needed. Quantifying sensor response is a significant challenge due to the sensitivity to ambient temperature and humidity and the cross-sensitivity to others pollutant species. This study reports the development of an Arduino compatible electronic board (AIRQino) which integrates a series of low-cost metal oxide and NDIR sensors for air quality monitoring, with sensors to measure air temperature, relative humidity, noise, solar radiation and vertical acceleration. A comparative assessment was made for CO2, CO, NO2, CH4, O3, VOCs concentrations, temperature and relative humidity. A controlled climatic chamber study (-80°C / +80°C) was performed to verify temperature and humidity interference using reference gas cylinders and high quality reference sensors. The AIRQino was installed on mobile vectors such as bikes, buses and trams in the cities of Firenze and Siracusa (Italy), that send data real-time to a Web portal. By integrating a microprocessor unit it is capable of directly updating calibration coefficients to provide corrected sensor output as digital string through RS232 serial port. Results from the lab tests and the 'real world' mobile applications are presented and discussed, to assess to what extent this sensor technology might be useful for the development of portable, compact, wireless and cost-effective system for air quality monitoring in urban areas at high spatio-temporal resolution.
Professional Learning 101: A Syllabus of Seven Protocols
ERIC Educational Resources Information Center
Fogarty, Robin; Pete, Brian
2010-01-01
Seven elements found in professional development research are necessary for successful professional development programs. High-quality professional learning must be sustained, job-embedded, collegial, interactive, integrative, practical, and results-oriented.
Plan-provider integration, premiums, and quality in the Medicare Advantage market.
Frakt, Austin B; Pizer, Steven D; Feldman, Roger
2013-12-01
To investigate how integration between Medicare Advantage plans and health care providers is related to plan premiums and quality ratings. We used public data from the Centers for Medicare and Medicaid Services (CMS) and the Area Resource File and private data from one large insurer. Premiums and quality ratings are from 2009 CMS administrative files and some control variables are historical. We estimated ordinary least-squares models for premiums and plan quality ratings, with state fixed effects and firm random effects. The key independent variable was an indicator of plan-provider integration. With the exception of Medigap premium data, all data were publicly available. We ascertained plan-provider integration through examination of plans' websites and governance documents. We found that integrated plan-providers charge higher premiums, controlling for quality. Such plans also have higher quality ratings. We found no evidence that integration is associated with more generous benefits. Current policy encourages plan-provider integration, although potential effects on health insurance products and markets are uncertain. Policy makers and regulators may want to closely monitor changes in premiums and quality after integration and consider whether quality improvement (if any) justifies premium increases (if they occur). © Health Research and Educational Trust.
Morgan, Martin; Anders, Simon; Lawrence, Michael; Aboyoun, Patrick; Pagès, Hervé; Gentleman, Robert
2009-01-01
Summary: ShortRead is a package for input, quality assessment, manipulation and output of high-throughput sequencing data. ShortRead is provided in the R and Bioconductor environments, allowing ready access to additional facilities for advanced statistical analysis, data transformation, visualization and integration with diverse genomic resources. Availability and Implementation: This package is implemented in R and available at the Bioconductor web site; the package contains a ‘vignette’ outlining typical work flows. Contact: mtmorgan@fhcrc.org PMID:19654119
Verdijk, Noortje A; Kasteleyn, Marise J; Harmans, Lara M; Talboom, Irvin JSH; Numans, Mattijs E; Chavannes, Niels H
2017-01-01
Background Worldwide, nearly 3 million people die of chronic obstructive pulmonary disease (COPD) every year. Integrated disease management (IDM) improves disease-specific quality of life and exercise capacity for people with COPD, but can also reduce hospital admissions and hospital days. Self-management of COPD through eHealth interventions has shown to be an effective method to improve the quality and efficiency of IDM in several settings, but it remains unknown which factors influence usage of eHealth and change in behavior of patients. Objective Our study, e-Vita COPD, compares different levels of integration of Web-based self-management platforms in IDM in three primary care settings. The main aim of this study is to analyze the factors that successfully promote the use of a self-management platform for COPD patients. Methods The e-Vita COPD study compares three different approaches to incorporating eHealth via Web-based self-management platforms into IDM of COPD using a parallel cohort design. Three groups integrated the platforms to different levels. In groups 1 (high integration) and 2 (medium integration), randomization was performed to two levels of personal assistance for patients (high and low assistance); in group 3 there was no integration into disease management (none integration). Every visit to the e-Vita and Zorgdraad COPD Web platforms was tracked objectively by collecting log data (sessions and services). At the first log-in, patients completed a baseline questionnaire. Baseline characteristics were automatically extracted from the log files including age, gender, education level, scores on the Clinical COPD Questionnaire (CCQ), dyspnea scale (MRC), and quality of life questionnaire (EQ5D). To predict the use of the platforms, multiple linear regression analyses for the different independent variables were performed: integration in IDM (high, medium, none), personal assistance for the participants (high vs low), educational level, and self-efficacy level (General Self-Efficacy Scale [GSES]). All analyses were adjusted for age and gender. Results Of the 702 invited COPD patients, 215 (30.6%) registered to a platform. Of the 82 patients in group 1 (high integration IDM), 36 were in group 1A (personal assistance) and 46 in group 1B (low assistance). Of the 96 patients in group 2 (medium integration IDM), 44 were in group 2A (telephone assistance) and 52 in group 2B (low assistance). A total of 37 patients participated in group 3 (no integration IDM). In all, 107 users (49.8%) visited the platform at least once in the 15-month period. The mean number of sessions differed between the three groups (group 1: mean 10.5, SD 1.3; group 2: mean 8.8, SD 1.4; group 3: mean 3.7, SD 1.8; P=.01). The mean number of sessions differed between the high-assistance and low-assistance groups in groups 1 and 2 (high: mean 11.8, SD 1.3; low: mean 6.7, SD 1.4; F1,80=6.55, P=.01). High-assistance participants used more services (mean 45.4, SD 6.2) than low-assistance participants (mean 21.2, SD 6.8; F1,80=6.82, P=.01). No association was found between educational level and usage and between GSES and usage. Conclusions Use of a self-management platform is higher when participants receive adequate personal assistance about how to use the platform. Blended care, where digital health and usual care are integrated, will likely lead to increased use of the online program. Future research should provide additional insights into the preferences of different patient groups. Trial Registration Nederlands Trial Register NTR4098; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=4098 (Archived by WebCite at http://www.webcitation.org/6qO1hqiJ1) PMID:28566268
ERIC Educational Resources Information Center
Bester, Susanna Jacoba
2016-01-01
Today's learners are born into a multimedia world and feel quite comfortable in an electronic learning environment. The high-quality sound, realistic colour images, graphics, narrations, real-time recordings and full motion videos from multimedia, which are integrated in History lessons, are what the learners of today want and need in their…
ERIC Educational Resources Information Center
National Academies Press, 2009
2009-01-01
In 1998, the National Science Foundation (NSF) launched a program of Grants for Vertical Integration of Research and Education in the Mathematical Sciences (VIGRE). These grants were designed for institutions with PhD-granting departments in the mathematical sciences, for the purpose of developing high-quality education programs, at all levels,…
1995-09-01
vital processes of a business. process, IDEF, method, methodology, modeling, knowledge acquisition, requirements definition, information systems... knowledge resources. Like manpower, materials, and machines, information and knowledge assets are recognized as vital resources that can be leveraged to...integrated enterprise. These technologies are designed to leverage information and knowledge resources as the key enablers for high quality systems
Information Integration for Concurrent Engineering (IICE) Compendium of Methods Report
1995-06-01
technological, economic, and strategic benefits can be attained through the effective capture, control, and management of information and knowledge ...resources. Like manpower, materials, and machines, information and knowledge assets are recognized as vital resources that can be leveraged to achieve...integrated enterprise. These technologies are designed to leverage information and knowledge resources as the key enablers for high quality systems that
Community Integration and Quality of Life in Aphasia after Stroke.
Lee, Hyejin; Lee, Yuna; Choi, Hyunsoo; Pyun, Sung-Bom
2015-11-01
To examine community integration and contributing factors in people with aphasia (PWA) following stroke and to investigate the relationship between community integration and quality of life (QOL). Thirty PWA and 42 age-and education-matched control subjects were involved. Main variables were as follows: socioeconomic status, mobility, and activity of daily living (ADL) (Modified Barthel Index), language function [Frenchay Aphasia Screening Test (FAST)], depression [Geriatric Depression Scale (GDS)], Community Integration Questionnaire (CIQ) and Stroke and Aphasia Quality of Life Scale-39 (SAQOL-39). Differences between aphasia and control groups and factors affecting community integration and QOL were analyzed. Home and social integration and productive activity were significantly decreased in the aphasia group compared to the control group; 8.5 and 18.3 points in total CIQ score, respectively. Amount of time spent outside the home and frequency of social contact were also significantly reduced in the aphasia group. Total mean score on the SAQOL-39 was 2.75±0.80 points and was significantly correlated with economic status, gait performance, ADL, depressive mood, and social domain score on the CIQ. Depression score measured by GDS was the single most important factor for the prediction of QOL, but the FAST score was significantly correlated only with the communication domain of the SAQOL-39. Community activities of PWA were very limited, and depression was highly associated with decreased community integration and QOL. Enhancing social participation and reducing emotional distress should be emphasized for rehabilitation of PWA.
2014-01-01
Background We recently demonstrated that quality of spirometry in primary care could markedly improve with remote offline support from specialized professionals. It is hypothesized that implementation of automatic online assessment of quality of spirometry using information and communication technologies may significantly enhance the potential for extensive deployment of a high quality spirometry program in integrated care settings. Objective The objective of the study was to elaborate and validate a Clinical Decision Support System (CDSS) for automatic online quality assessment of spirometry. Methods The CDSS was done through a three step process including: (1) identification of optimal sampling frequency; (2) iterations to build-up an initial version using the 24 standard spirometry curves recommended by the American Thoracic Society; and (3) iterations to refine the CDSS using 270 curves from 90 patients. In each of these steps the results were checked against one expert. Finally, 778 spirometry curves from 291 patients were analyzed for validation purposes. Results The CDSS generated appropriate online classification and certification in 685/778 (88.1%) of spirometry testing, with 96% sensitivity and 95% specificity. Conclusions Consequently, only 93/778 (11.9%) of spirometry testing required offline remote classification by an expert, indicating a potential positive role of the CDSS in the deployment of a high quality spirometry program in an integrated care setting. PMID:25600957
Wurtzite-Phased InP Micropillars Grown on Silicon with Low Surface Recombination Velocity.
Li, Kun; Ng, Kar Wei; Tran, Thai-Truong D; Sun, Hao; Lu, Fanglu; Chang-Hasnain, Connie J
2015-11-11
The direct growth of III-V nanostructures on silicon has shown great promise in the integration of optoelectronics with silicon-based technologies. Our previous work showed that scaling up nanostructures to microsize while maintaining high quality heterogeneous integration opens a pathway toward a complete photonic integrated circuit and high-efficiency cost-effective solar cells. In this paper, we present a thorough material study of novel metastable InP micropillars monolithically grown on silicon, focusing on two enabling aspects of this technology-the stress relaxation mechanism at the heterogeneous interface and the microstructure surface quality. Aberration-corrected transmission electron microscopy studies show that InP grows directly on silicon without any amorphous layer in between. A set of periodic dislocations was found at the heterointerface, relaxing the 8% lattice mismatch between InP and Si. Single crystalline InP therefore can grow on top of the fully relaxed template, yielding high-quality micropillars with diameters expanding beyond 1 μm. An interesting power-dependence trend of carrier recombination lifetimes was captured for these InP micropillars at room temperature, for the first time for micro/nanostructures. By simply combining internal quantum efficiency with carrier lifetime, we revealed the recombination dynamics of nonradiative and radiative portions separately. A very low surface recombination velocity of 1.1 × 10(3) cm/sec was obtained. In addition, we experimentally estimated the radiative recombination B coefficient of 2.0 × 10(-10) cm(3)/sec for pure wurtzite-phased InP. These values are comparable with those obtained from InP bulk. Exceeding the limits of conventional nanowires, our InP micropillars combine the strengths of both nanostructures and bulk materials and will provide an avenue in heterogeneous integration of III-V semiconductor materials onto silicon platforms.
NASA Astrophysics Data System (ADS)
Buruaem, Lucas Moreira; de Castro, Ítalo Braga; Hortellani, Marcos Antonio; Taniguchi, Satie; Fillmann, Gilberto; Sasaki, Silvio Tarou; Varella Petti, Mônica Angélica; Sarkis, Jorge Eduardo de Souza; Bícego, Márcia Caruso; Maranho, Luciane Alves; Davanso, Marcela Bergo; Nonato, Edmundo Ferraz; Cesar, Augusto; Costa-Lotufo, Leticia Veras; Abessa, Denis Moledo de Souza
2013-09-01
Santos-São Vicente Estuarine System is a highly populated coastal zone in Brazil and where it is located the major port of Latin America. Historically, port activities, industrial and domestic effluents discharges have constituted the main sources of contaminants to estuarine system. This study aimed to assess the recent status of sediment quality from 5 zones of Port of Santos by applying a lines-of-evidence approach through integrating results of: (1) acute toxicity of whole sediment and chronic toxicity of liquid phases; (2) grain size, organic matter, organic carbon, nitrogen, phosphorus, trace metals, polycyclic aromatic hydrocarbons, linear alkylbenzenes and butyltins; (3) benthic community descriptors. Results revealed a gradient of increasing contamination for metals and organic compounds, alongside with their geochemical carriers. Sediment liquid phases were more toxic compared to whole sediment. Low number of species and individuals indicated the impoverishment of benthic community. The use of site-specific sediment quality guidelines was more appropriate to predict sediment toxicity. The integration of results through Sediment Quality Triad approach and principal component analysis allowed observing the effects of natural stressors and dredging on sediment quality and benthic distribution. Even with recent governmental efforts to control, pollution is still relevant in Port of Santos and a threat to local ecosystems.
Automating PACS quality control with the Vanderbilt image processing enterprise resource
NASA Astrophysics Data System (ADS)
Esparza, Michael L.; Welch, E. Brian; Landman, Bennett A.
2012-02-01
Precise image acquisition is an integral part of modern patient care and medical imaging research. Periodic quality control using standardized protocols and phantoms ensures that scanners are operating according to specifications, yet such procedures do not ensure that individual datasets are free from corruption; for example due to patient motion, transient interference, or physiological variability. If unacceptable artifacts are noticed during scanning, a technologist can repeat a procedure. Yet, substantial delays may be incurred if a problematic scan is not noticed until a radiologist reads the scans or an automated algorithm fails. Given scores of slices in typical three-dimensional scans and widevariety of potential use cases, a technologist cannot practically be expected inspect all images. In large-scale research, automated pipeline systems have had great success in achieving high throughput. However, clinical and institutional workflows are largely based on DICOM and PACS technologies; these systems are not readily compatible with research systems due to security and privacy restrictions. Hence, quantitative quality control has been relegated to individual investigators and too often neglected. Herein, we propose a scalable system, the Vanderbilt Image Processing Enterprise Resource (VIPER) to integrate modular quality control and image analysis routines with a standard PACS configuration. This server unifies image processing routines across an institutional level and provides a simple interface so that investigators can collaborate to deploy new analysis technologies. VIPER integrates with high performance computing environments has successfully analyzed all standard scans from our institutional research center over the course of the last 18 months.
Turnaround Arts Initiative: Summary of Key Findings
ERIC Educational Resources Information Center
Stoelinga, Sara Ray; Silk, Yael; Reddy, Prateek; Rahman, Nadiv
2015-01-01
Turnaround Arts is a public-private partnership that aims to test the hypothesis that strategically implementing high-quality and integrated arts education programming in high-poverty, chronically underperforming schools adds significant value to school-wide reform. In 2014, the Turnaround Arts initiative completed an evaluation report covering…
Rangé, G; Chassaing, S; Marcollet, P; Saint-Étienne, C; Dequenne, P; Goralski, M; Bardiére, P; Beverilli, F; Godillon, L; Sabine, B; Laure, C; Gautier, S; Hakim, R; Albert, F; Angoulvant, D; Grammatico-Guillon, L
2018-05-01
To assess the reliability and low cost of a computerized interventional cardiology (IC) registry to prospectively and systematically collect high-quality data for all consecutive coronary patients referred for coronary angiogram or/and coronary angioplasty. Rigorous clinical practice assessment is a key factor to improve prognosis in IC. A prospective and permanent registry could achieve this goal but, presumably, at high cost and low level of data quality. One multicentric IC registry (CRAC registry), fully integrated to usual coronary activity report software, started in the centre Val-de-Loire (CVL) French region in 2014. Quality assessment of CRAC registry was conducted on five IC CathLab of the CVL region, from January 1st to December 31st 2014. Quality of collected data was evaluated by measuring procedure exhaustivity (comparing with data from hospital information system), data completeness (quality controls) and data consistency (by checking complete medical charts as gold standard). Cost per procedure (global registry operating cost/number of collected procedures) was also estimated. CRAC model provided a high-quality level with 98.2% procedure completeness, 99.6% data completeness and 89% data consistency. The operating cost per procedure was €14.70 ($16.51) for data collection and quality control, including ST-segment elevation myocardial infarction (STEMI) preadmission information and one-year follow-up after angioplasty. This integrated computerized IC registry led to the construction of an exhaustive, reliable and costless database, including all coronary patients entering in participating IC centers in the CVL region. This solution will be developed in other French regions, setting up a national IC database for coronary patients in 2020: France PCI. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Martini, Markus; Pinggera, Jakob; Neurauter, Manuel; Sachse, Pierre; Furtner, Marco R.; Weber, Barbara
2016-05-01
A process model (PM) represents the graphical depiction of a business process, for instance, the entire process from online ordering a book until the parcel is delivered to the customer. Knowledge about relevant factors for creating PMs of high quality is lacking. The present study investigated the role of cognitive processes as well as modelling processes in creating a PM in experienced and inexperienced modellers. Specifically, two working memory (WM) functions (holding and processing of information and relational integration) and three process of process modelling phases (comprehension, modelling, and reconciliation) were related to PM quality. Our results show that the WM function of relational integration was positively related to PM quality in both modelling groups. The ratio of comprehension phases was negatively related to PM quality in inexperienced modellers and the ratio of reconciliation phases was positively related to PM quality in experienced modellers. Our research reveals central cognitive mechanisms in process modelling and has potential practical implications for the development of modelling software and teaching the craft of process modelling.
Martini, Markus; Pinggera, Jakob; Neurauter, Manuel; Sachse, Pierre; Furtner, Marco R.; Weber, Barbara
2016-01-01
A process model (PM) represents the graphical depiction of a business process, for instance, the entire process from online ordering a book until the parcel is delivered to the customer. Knowledge about relevant factors for creating PMs of high quality is lacking. The present study investigated the role of cognitive processes as well as modelling processes in creating a PM in experienced and inexperienced modellers. Specifically, two working memory (WM) functions (holding and processing of information and relational integration) and three process of process modelling phases (comprehension, modelling, and reconciliation) were related to PM quality. Our results show that the WM function of relational integration was positively related to PM quality in both modelling groups. The ratio of comprehension phases was negatively related to PM quality in inexperienced modellers and the ratio of reconciliation phases was positively related to PM quality in experienced modellers. Our research reveals central cognitive mechanisms in process modelling and has potential practical implications for the development of modelling software and teaching the craft of process modelling. PMID:27157858
Martini, Markus; Pinggera, Jakob; Neurauter, Manuel; Sachse, Pierre; Furtner, Marco R; Weber, Barbara
2016-05-09
A process model (PM) represents the graphical depiction of a business process, for instance, the entire process from online ordering a book until the parcel is delivered to the customer. Knowledge about relevant factors for creating PMs of high quality is lacking. The present study investigated the role of cognitive processes as well as modelling processes in creating a PM in experienced and inexperienced modellers. Specifically, two working memory (WM) functions (holding and processing of information and relational integration) and three process of process modelling phases (comprehension, modelling, and reconciliation) were related to PM quality. Our results show that the WM function of relational integration was positively related to PM quality in both modelling groups. The ratio of comprehension phases was negatively related to PM quality in inexperienced modellers and the ratio of reconciliation phases was positively related to PM quality in experienced modellers. Our research reveals central cognitive mechanisms in process modelling and has potential practical implications for the development of modelling software and teaching the craft of process modelling.
ERIC Educational Resources Information Center
Wang, Erh-Hsuan
2016-01-01
Improving the quality of healthcare while simultaneously reducing its overall costs remains a challenge. One of the recommended approaches for achieving this goal is to build high quality data collection and reporting systems to facilitate evidence-based practice (EBP), which emphasizes the importance of using the solid evidence available to make…
ERIC Educational Resources Information Center
Nesmith, Suzanne; Cooper, Sandi
2010-01-01
The integration of children's trade books in the mathematics classroom has experienced a dramatic surge in its popularity; yet, though the positive benefits of this strategy have been well documented, these benefits may only be realized if the literature is of high quality. Utilizing a mathematics trade book evaluation instrument, this inquiry…
Hybrid imaging: a quantum leap in scientific imaging
NASA Astrophysics Data System (ADS)
Atlas, Gene; Wadsworth, Mark V.
2004-01-01
ImagerLabs has advanced its patented next generation imaging technology called the Hybrid Imaging Technology (HIT) that offers scientific quality performance. The key to the HIT is the merging of the CCD and CMOS technologies through hybridization rather than process integration. HIT offers exceptional QE, fill factor, broad spectral response and very low noise properties of the CCD. In addition, it provides the very high-speed readout, low power, high linearity and high integration capability of CMOS sensors. In this work, we present the benefits, and update the latest advances in the performance of this exciting technology.
Rawat, Angeli; Uebel, Kerry; Moore, David; Cingl, Lubomir; Yassi, Annalee
2018-05-16
HIV care integrated into primary health care (PHC) encourages reorganized service delivery but could increase workload. In 2012-2013, we surveyed 910 patients and caregivers at two time points after integration in four clinics in Free State, South Africa. Likert surveys measured quality of care (QoC) and satisfaction with staff (SwS). QoC scores were lower for females, those older than 56 years, those visiting clinics every 3 months, and child health participants. Regression estimates showed QoC scores higher for ages 36-45 versus 18-25 years, and lower for those attending clinics for more than 10 years versus 6-12 months. Overall, SwS scores were lower for child health attendees and higher for tuberculosis attendees compared to chronic disease care attendees. Research is needed to understand determinants of disparities in QoC and SwS, especially for child health, diabetes, and hypertension attendees, to ensure high-quality care experiences for all patients attending PHC clinics with integrated HIV care. Copyright © 2018 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.
Ocampo-Duque, William; Osorio, Carolina; Piamba, Christian; Schuhmacher, Marta; Domingo, José L
2013-02-01
The integration of water quality monitoring variables is essential in environmental decision making. Nowadays, advanced techniques to manage subjectivity, imprecision, uncertainty, vagueness, and variability are required in such complex evaluation process. We here propose a probabilistic fuzzy hybrid model to assess river water quality. Fuzzy logic reasoning has been used to compute a water quality integrative index. By applying a Monte Carlo technique, based on non-parametric probability distributions, the randomness of model inputs was estimated. Annual histograms of nine water quality variables were built with monitoring data systematically collected in the Colombian Cauca River, and probability density estimations using the kernel smoothing method were applied to fit data. Several years were assessed, and river sectors upstream and downstream the city of Santiago de Cali, a big city with basic wastewater treatment and high industrial activity, were analyzed. The probabilistic fuzzy water quality index was able to explain the reduction in water quality, as the river receives a larger number of agriculture, domestic, and industrial effluents. The results of the hybrid model were compared to traditional water quality indexes. The main advantage of the proposed method is that it considers flexible boundaries between the linguistic qualifiers used to define the water status, being the belongingness of water quality to the diverse output fuzzy sets or classes provided with percentiles and histograms, which allows classify better the real water condition. The results of this study show that fuzzy inference systems integrated to stochastic non-parametric techniques may be used as complementary tools in water quality indexing methodologies. Copyright © 2012 Elsevier Ltd. All rights reserved.
Hall, Jacqueline A; Brown, Robert
2013-09-27
The integration of molecular information in clinical decision making is becoming a reality. These changes are shaping the way clinical research is conducted, and as reality sets in, the challenges in conducting, managing and organising multi-disciplinary research become apparent. Clinical trials provide a platform to conduct translational research (TR) within the context of high quality clinical data accrual. Integrating TR objectives in trials allows the execution of pivotal studies that provide clinical evidence for biomarker-driven treatment strategies, targeting early drug development trials to a homogeneous and well defined patient population, supports the development of companion diagnostics and provides an opportunity for deepening our understanding of cancer biology and mechanisms of drug action. To achieve these goals within a clinical trial, developing translational research infrastructure and capabilities (TRIC) plays a critical catalytic role for translating preclinical data into successful clinical research and development. TRIC represents a technical platform, dedicated resources and access to expertise promoting high quality standards, logistical and operational support and unified streamlined procedures under an appropriate governance framework. TRIC promotes integration of multiple disciplines including biobanking, laboratory analysis, molecular data, informatics, statistical analysis and dissemination of results which are all required for successful TR projects and scientific progress. Such a supporting infrastructure is absolutely essential in order to promote high quality robust research, avoid duplication and coordinate resources. Lack of such infrastructure, we would argue, is one reason for the limited effect of TR in clinical practice beyond clinical trials.
Gonzalez, Maria E; Barrett, Diane M
2010-01-01
Advanced food processing methods that accomplish inactivation of microorganisms but minimize adverse thermal exposure are of great interest to the food industry. High pressure (HP) and pulsed electric field (PEF) processing are commercially applied to produce high quality fruit and vegetable products in the United States, Europe, and Japan. Both microbial and plant cell membranes are significantly altered following exposure to heat, HP, or PEF. Our research group sought to quantify the degree of damage to plant cell membranes that occurs as a result of exposure to heat, HP, or PEF, using the same analytical methods. In order to evaluate whether new advanced processing methods are superior to traditional thermal processing methods, it is necessary to compare them. In this review, we describe the existing state of knowledge related to effects of heat, HP, and PEF on both microbial and plant cells. The importance and relevance of compartmentalization in plant cells as it relates to fruit and vegetable quality is described and various methods for quantification of plant cell membrane integrity are discussed. These include electrolyte leakage, cell viability, and proton nuclear magnetic resonance (1H-NMR). PMID:20492210
Gonzalez, Maria E; Barrett, Diane M
2010-09-01
Advanced food processing methods that accomplish inactivation of microorganisms but minimize adverse thermal exposure are of great interest to the food industry. High pressure (HP) and pulsed electric field (PEF) processing are commercially applied to produce high quality fruit and vegetable products in the United States, Europe, and Japan. Both microbial and plant cell membranes are significantly altered following exposure to heat, HP, or PEF. Our research group sought to quantify the degree of damage to plant cell membranes that occurs as a result of exposure to heat, HP, or PEF, using the same analytical methods. In order to evaluate whether new advanced processing methods are superior to traditional thermal processing methods, it is necessary to compare them. In this review, we describe the existing state of knowledge related to effects of heat, HP, and PEF on both microbial and plant cells. The importance and relevance of compartmentalization in plant cells as it relates to fruit and vegetable quality is described and various methods for quantification of plant cell membrane integrity are discussed. These include electrolyte leakage, cell viability, and proton nuclear magnetic resonance (¹H-NMR).
Novel Integration of Frame Rate Up Conversion and HEVC Coding Based on Rate-Distortion Optimization.
Guo Lu; Xiaoyun Zhang; Li Chen; Zhiyong Gao
2018-02-01
Frame rate up conversion (FRUC) can improve the visual quality by interpolating new intermediate frames. However, high frame rate videos by FRUC are confronted with more bitrate consumption or annoying artifacts of interpolated frames. In this paper, a novel integration framework of FRUC and high efficiency video coding (HEVC) is proposed based on rate-distortion optimization, and the interpolated frames can be reconstructed at encoder side with low bitrate cost and high visual quality. First, joint motion estimation (JME) algorithm is proposed to obtain robust motion vectors, which are shared between FRUC and video coding. What's more, JME is embedded into the coding loop and employs the original motion search strategy in HEVC coding. Then, the frame interpolation is formulated as a rate-distortion optimization problem, where both the coding bitrate consumption and visual quality are taken into account. Due to the absence of original frames, the distortion model for interpolated frames is established according to the motion vector reliability and coding quantization error. Experimental results demonstrate that the proposed framework can achieve 21% ~ 42% reduction in BDBR, when compared with the traditional methods of FRUC cascaded with coding.
Development of a 0.5m clear aperture Cassegrain type collimator telescope
NASA Astrophysics Data System (ADS)
Ekinci, Mustafa; Selimoǧlu, Özgür
2016-07-01
Collimator is an optical instrument used to evaluate performance of high precision instruments, especially space-born high resolution telescopes. Optical quality of the collimator telescope needs to be better than the instrument to be measured. This requirement leads collimator telescope to be a very precise instrument with high quality mirrors and a stable structure to keep it operational under specified conditions. In order to achieve precision requirements and to ensure repeatability of the mounts for polishing and metrology, opto-mechanical principles are applied to mirror mounts. Finite Element Method is utilized to simulate gravity effects, integration errors and temperature variations. Finite element analyses results of deformed optical surfaces are imported to optical domain by using Zernike polynomials to evaluate the design against specified WFE requirements. Both mirrors are aspheric and made from Zerodur for its stability and near zero CTE, M1 is further light-weighted. Optical quality measurements of the mirrors are achieved by using custom made CGHs on an interferometric test setup. Spider of the Cassegrain collimator telescope has a flexural adjustment mechanism driven by precise micrometers to overcome tilt errors originating from finite stiffness of the structure and integration errors. Collimator telescope is assembled and alignment methods are proposed.
Strategy Guideline: Quality Management in Existing Homes; Cantilever Floor Example
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taggart, J.; Sikora, J.; Wiehagen, J.
2011-12-01
This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented. The goal of existing home high performing remodeling quality management systems (HPR-QMS) is to establish practices and processes that can be used throughout any remodeling project. The research presented in this document provides a comparison of a selected retrofit activity as typically done versus that same retrofit activity approached from an integrated high performance remodeling andmore » quality management perspective. It highlights some key quality management tools and approaches that can be adopted incrementally by a high performance remodeler for this or any high performance retrofit. This example is intended as a template and establishes a methodology that can be used to develop a portfolio of high performance remodeling strategies.« less
Madzimbamuto, Farai D; Ray, Sunanda; Mogobe, Keitshokile D
2013-06-10
The failure to reduce preventable maternal deaths represents a violation of women's right to life, health, non-discrimination and equality. Maternal deaths result from weaknesses in health systems: inadequate financing of services, poor information systems, inefficient logistics management and most important, the lack of investment in the most valuable resource, the human resource of health workers. Inadequate senior leadership, poor communication and low staff morale are cited repeatedly in explaining low quality of healthcare. Vertical programmes undermine other service areas by creating competition for scarce skilled staff, separate reporting systems and duplication of training and tasks. Confidential enquiries and other quality-improvement activities have identified underlying causes of maternal deaths, but depend on the health system to respond with remedies. Instead of separate vertical programmes for management of HIV, tuberculosis, and reproductive health, integration of care and joint management of pregnancy and HIV would be more effective. Addressing health system failures that lead to each woman's death would have a wider impact on improving the quality of care provided in the health service as a whole. More could be achieved if existing resources were used more effectively. The challenge for African countries is how to get into practice interventions known from research to be effective in improving quality of care. Advocacy and commitment to saving women's lives are crucial elements for campaigns to influence governments and policy -makers to act on the findings of these enquiries. Health professional training curricula should be updated to include perspectives on patients' rights, communication skills, and integrated approaches, while using adult learning methods and problem-solving techniques. In countries with high rates of Human Immunodeficiency Virus (HIV), indirect causes of maternal deaths from HIV-associated infections now exceed direct causes of hemorrhage, hypertension and sepsis. Advocacy for all pregnant HIV-positive women to be on anti-retroviral therapy must extend to improvements in the quality of service offered, better organised obstetric services and integration of clinical HIV care into maternity services. Improved communication and specialist support to peripheral facilities can be facilitated through advances in technology such as mobile phones.
Plan–Provider Integration, Premiums, and Quality in the Medicare Advantage Market
Frakt, Austin B; Pizer, Steven D; Feldman, Roger
2013-01-01
Objective. To investigate how integration between Medicare Advantage plans and health care providers is related to plan premiums and quality ratings. Data Source. We used public data from the Centers for Medicare and Medicaid Services (CMS) and the Area Resource File and private data from one large insurer. Premiums and quality ratings are from 2009 CMS administrative files and some control variables are historical. Study Design. We estimated ordinary least-squares models for premiums and plan quality ratings, with state fixed effects and firm random effects. The key independent variable was an indicator of plan–provider integration. Data Collection. With the exception of Medigap premium data, all data were publicly available. We ascertained plan–provider integration through examination of plans’ websites and governance documents. Principal Findings. We found that integrated plan–providers charge higher premiums, controlling for quality. Such plans also have higher quality ratings. We found no evidence that integration is associated with more generous benefits. Conclusions. Current policy encourages plan–provider integration, although potential effects on health insurance products and markets are uncertain. Policy makers and regulators may want to closely monitor changes in premiums and quality after integration and consider whether quality improvement (if any) justifies premium increases (if they occur). PMID:23800017
Smith, Alan D; Offodile, O Felix
2008-01-01
The limitations, immeasurable, and seemly unquantifiable aspects of the healthcare service industry, make it imperative that quality assurance programs include total quality management (TQM) and automatic identification and data capture (AIDC)-related technologies. Most of standards used in TQM and AIDC require data, to measure improvement and achieve standardization. Major difference between managing a service firm and managing a product-manufacturing firm is the difficulty of achieving consistently high quality. Examination of two different healthcare service providers in the Pittsburgh, Pennsylvania area offers different views as to the implementation and practice of total quality management techniques and AIDC integration. Since the healthcare service industry must take into account its high customization needs, there are positive steps to make the hospital structure itself more patient friendly and quality related; hence improving its heath-marketing strategies to the general public.
Ludikhuyze, L; Van Loey, A; Indrawati; Smout, C; Hendrickx, M
2003-01-01
Throughout the last decade, high pressure technology has been shown to offer great potential to the food processing and preservation industry in delivering safe and high quality products. Implementation of this new technology will be largely facilitated when a scientific basis to assess quantitatively the impact of high pressure processes on food safety and quality becomes available. Besides, quantitative data on the effects of pressure and temperature on safety and quality aspects of foods are indispensable for design and evaluation of optimal high pressure processes, i.e., processes resulting in maximal quality retention within the constraints of the required reduction of microbial load and enzyme activity. Indeed it has to be stressed that new technologies should deliver, apart from the promised quality improvement, an equivalent or preferably enhanced level of safety. The present paper will give an overview from a quantitative point of view of the combined effects of pressure and temperature on enzymes related to quality of fruits and vegetables. Complete kinetic characterization of the inactivation of the individual enzymes will be discussed, as well as the use of integrated kinetic information in process engineering.
Saunders, Hannele
2015-07-01
To describe quantitative and qualitative best evidence as sources for practical interventions usable in daily care delivery in order to integrate best evidence into clinical decision-making at local practice settings. To illustrate the development, implementation and evaluation of a pain management nursing care bundle based on a clinical practice guideline via a real-world clinical exemplar. Successful implementation of evidence-based practice requires consistent integration of best evidence into daily clinical decision-making. Best evidence comprises high-quality knowledge summarised in systematic reviews and translated into guidelines. However, consistent integration of guidelines into care delivery remains challenging, partly due to guidelines not being in a usable form for daily practice or relevant for the local context. A position paper with a clinical exemplar of a nurse-led, evidence-based quality improvement project to design, implement and evaluate a pain management care bundle translated from a national nursing guideline. A pragmatic approach to integrating guidelines into daily practice is presented. Best evidence from a national nursing guideline was translated into a pain management care bundle and integrated into daily practice in 15 medical-surgical (med-surg) units of nine hospitals of a large university hospital system in Finland. Translation of best evidence from guidelines into usable form as care bundles adapted to the local setting may increase implementation and uptake of guidelines and improve quality and consistency of care delivery. A pragmatic approach to translating a nursing guideline into a pain management care bundle to incorporate best evidence into daily practice may help achieve more consistent and equitable integration of guidelines into care delivery, and better quality of pain management and patient outcomes. © 2015 John Wiley & Sons Ltd.
Beyond integration: challenges for children's mental health.
Knitzer, Jane; Cooper, Janice
2006-01-01
This paper reviews access, outcomes, and quality in the children's mental health system. We contend that a major focal point of future reforms should be at the organization level of care delivery. We identify five areas for intentional policy action to better infuse quality into the system. We also call for building upon the momentum of recent high-visibility reform proposals and for renewed advocacy to advance quality-linked perspectives into the children's mental health system beyond its focus on children with severe emotional disturbances.
Iyappan, Anandhi; Kawalia, Shweta Bagewadi; Raschka, Tamara; Hofmann-Apitius, Martin; Senger, Philipp
2016-07-08
Neurodegenerative diseases are incurable and debilitating indications with huge social and economic impact, where much is still to be learnt about the underlying molecular events. Mechanistic disease models could offer a knowledge framework to help decipher the complex interactions that occur at molecular and cellular levels. This motivates the need for the development of an approach integrating highly curated and heterogeneous data into a disease model of different regulatory data layers. Although several disease models exist, they often do not consider the quality of underlying data. Moreover, even with the current advancements in semantic web technology, we still do not have cure for complex diseases like Alzheimer's disease. One of the key reasons accountable for this could be the increasing gap between generated data and the derived knowledge. In this paper, we describe an approach, called as NeuroRDF, to develop an integrative framework for modeling curated knowledge in the area of complex neurodegenerative diseases. The core of this strategy lies in the usage of well curated and context specific data for integration into one single semantic web-based framework, RDF. This increases the probability of the derived knowledge to be novel and reliable in a specific disease context. This infrastructure integrates highly curated data from databases (Bind, IntAct, etc.), literature (PubMed), and gene expression resources (such as GEO and ArrayExpress). We illustrate the effectiveness of our approach by asking real-world biomedical questions that link these resources to prioritize the plausible biomarker candidates. Among the 13 prioritized candidate genes, we identified MIF to be a potential emerging candidate due to its role as a pro-inflammatory cytokine. We additionally report on the effort and challenges faced during generation of such an indication-specific knowledge base comprising of curated and quality-controlled data. Although many alternative approaches have been proposed and practiced for modeling diseases, the semantic web technology is a flexible and well established solution for harmonized aggregation. The benefit of this work, to use high quality and context specific data, becomes apparent in speculating previously unattended biomarker candidates around a well-known mechanism, further leveraged for experimental investigations.
Zhao, Jing; Zhang, Ting; Liu, Yongfeng; Wang, Xingyu; Zhang, Lan; Ku, Ting; Quek, Siew Young
2018-09-15
Freezing is a practical method for meat preservation but the quality of frozen meat can deteriorate with storage time. This research investigated the effect of frozen storage time (up to 66 months) on changes in DNA yield, purity and integrity in beef, and further analyzed the correlation between beef quality (moisture content, protein content, TVB-N value and pH value) and DNA quality in an attempt to establish a reliable, high-throughput method for meat quality control. Results showed that frozen storage time influenced the yield and integrity of DNA significantly (p < 0.05). The DNA yield decreased as frozen storage time increased due to DNA degradation. The half-life (t 1/2 = ln2/0.015) was calculated as 46 months. The DNA quality degraded dramatically with the increased storage time based on gel electrophoresis results. Polymerase chain reaction (PCR) products from both mitochondrial DNA (mtDNA) and nuclear DNA (nDNA) were observed in all frozen beef samples. Using real-time PCR for quantitative assessment of DNA and meat quality revealed that correlations could be established successfully with mathematical models to evaluate frozen beef quality. Copyright © 2018 Elsevier Ltd. All rights reserved.
Meaney, Peter A; Bobrow, Bentley J; Mancini, Mary E; Christenson, Jim; de Caen, Allan R; Bhanji, Farhan; Abella, Benjamin S; Kleinman, Monica E; Edelson, Dana P; Berg, Robert A; Aufderheide, Tom P; Menon, Venu; Leary, Marion
2013-07-23
The "2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care" increased the focus on methods to ensure that high-quality cardiopulmonary resuscitation (CPR) is performed in all resuscitation attempts. There are 5 critical components of high-quality CPR: minimize interruptions in chest compressions, provide compressions of adequate rate and depth, avoid leaning between compressions, and avoid excessive ventilation. Although it is clear that high-quality CPR is the primary component in influencing survival from cardiac arrest, there is considerable variation in monitoring, implementation, and quality improvement. As such, CPR quality varies widely between systems and locations. Victims often do not receive high-quality CPR because of provider ambiguity in prioritization of resuscitative efforts during an arrest. This ambiguity also impedes the development of optimal systems of care to increase survival from cardiac arrest. This consensus statement addresses the following key areas of CPR quality for the trained rescuer: metrics of CPR performance; monitoring, feedback, and integration of the patient's response to CPR; team-level logistics to ensure performance of high-quality CPR; and continuous quality improvement on provider, team, and systems levels. Clear definitions of metrics and methods to consistently deliver and improve the quality of CPR will narrow the gap between resuscitation science and the victims, both in and out of the hospital, and lay the foundation for further improvements in the future.
2017-01-01
Integrated single-photon sources with high photon-extraction efficiency are key building blocks for applications in the field of quantum communications. We report on a bright single-photon source realized by on-chip integration of a deterministic quantum dot microlens with a 3D-printed multilens micro-objective. The device concept benefits from a sophisticated combination of in situ 3D electron-beam lithography to realize the quantum dot microlens and 3D femtosecond direct laser writing for creation of the micro-objective. In this way, we obtain a high-quality quantum device with broadband photon-extraction efficiency of (40 ± 4)% and high suppression of multiphoton emission events with g(2)(τ = 0) < 0.02. Our results highlight the opportunities that arise from tailoring the optical properties of quantum emitters using integrated optics with high potential for the further development of plug-and-play fiber-coupled single-photon sources. PMID:28670600
Watson, Karriem S; Blok, Amanda C; Buscemi, Joanna; Molina, Yamile; Fitzgibbon, Marian; Simon, Melissa A; Williams, Lance; Matthews, Kameron; Studts, Jamie L; Lillie, Sarah E; Ostroff, Jamie S; Carter-Harris, Lisa; Winn, Robert A
2016-12-01
The Society of Behavioral Medicine (SBM) supports the United States Preventive Services Task Force (USPSTF) recommendation of low-dose computed tomography (LDCT) screening of the chest for eligible populations to reduce lung cancer mortality. Consistent with efforts to translate research findings into real-world settings, SBM encourages health-care providers and health-care systems to (1) integrate evidence-based tobacco treatment as an essential component of LDCT-based lung cancer screening, (2) examine the structural barriers that may impact screening uptake, and (3) incorporate shared decision-making as a clinical platform to facilitate consultations and engagement with individuals at high risk for lung cancer about the potential benefits and harms associated with participation in a lung cancer screening program. We advise policy makers and legislators to support screening in high-risk populations by continuing to (1) expand access to high quality LDCT-based screening among underserved high-risk populations, (2) enhance cost-effectiveness by integrating evidence-based tobacco treatments into screening in high-risk populations, and (3) increase funding for research that explores implementation science and increased public awareness and access of diverse populations to participate in clinical and translational research.
NASA Astrophysics Data System (ADS)
Kersten, Jennifer Anna
In recent years there has been increasing interest in engineering education at the K-12 level, which has resulted in states adopting engineering standards as a part of their academic science standards. From a national perspective, the basis for research into engineering education at the K-12 level is the belief that it is of benefit to student learning, including to "improve student learning and achievement in science and mathematics; increase awareness of engineering and the work of engineers; boost youth interest in pursuing engineering as a career; and increase the technological literacy of all students" (National Research Council, 2009a, p. 1). The above has led to a need to understand how teachers are currently implementing engineering education in their classrooms. High school physics teachers have a history of implementing engineering design projects in their classrooms, thus providing an appropriate setting to look for evidence of quality engineering education at the high school level. Understanding the characteristics of quality engineering integration can inform curricular and professional development efforts for teachers asked to implement engineering in their classrooms. Thus, the question that guided this study is: How, and to what extent, do physics teachers represent quality engineering in a physics unit focused on engineering? A case study research design was implemented for this project. Three high school physics teachers were participants in this study focused on the integration of engineering education into the physics classroom. The data collected included observations, interviews, and classroom documents that were analyzed using the Framework for Quality K-12 Engineering Education (Moore, Glancy et al., 2013). The results provided information about the areas of the K-12 engineering framework addressed during these engineering design projects, and detailed the quality of these lesson components. The results indicate that all of the design projects contained components of the indicators central to engineering education, although with varied degrees of success. In addition, each design project contained aspects important to the development of students' understanding of engineering and that promote important professional skills used by engineers. The implications of this work are discussed at the teacher, school, professional development, and policy levels.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... Integrated List Water Quality Assessment AGENCY: Delaware River Basin Commission. ACTION: Notice. SUMMARY... Integrated List Water Quality Assessment is available for review and comment. DATES: Comments must be... should have the phrase ``Water Quality Assessment 2012'' in the subject line and should include the name...
Integrated RF-shim coil allowing two degrees of freedom shim current.
Jiazheng Zhou; Ying-Hua Chu; Yi-Cheng Hsu; Pu-Yeh Wu; Stockmann, Jason P; Fa-Hsuan Lin
2016-08-01
High-quality magnetic resonance imaging and spectroscopic measurements require a highly homogeneous magnetic field. Different from global shimming, localized off-resonance can be corrected by using multi-coil shimming. Previously, integrated RF and shimming coils have been used to implement multi-coil shimming. Such coils share the same conductor for RF signal reception and shim field generation. Here we propose a new design of the integrated RF-shim coil at 3-tesla, where two independent shim current paths are allowed in each coil. This coil permits a higher degree of freedom in shim current distribution design. We use both phantom experiments and simulations to demonstrate the feasibility of this new design.
Integrated editing system for Japanese text and image information "Linernote"
NASA Astrophysics Data System (ADS)
Tanaka, Kazuto
Integrated Japanese text editing system "Linernote" developed by Toyo Industries Co. is explained. The system has been developed on the concept of electronic publishing. It is composed of personal computer NEC PC-9801 VX and other peripherals. Sentence, drawing and image data is inputted and edited under the integrated operating environment in the system and final text is printed out by laser printer. Handling efficiency of time consuming work such as pattern input or page make up has been improved by draft image data indication method on CRT. It is the latest DTP system equipped with three major functions, namly, typesetting for high quality text editing, easy drawing/tracing and high speed image processing.
Xiang, X D
Combinatorial materials synthesis methods and high-throughput evaluation techniques have been developed to accelerate the process of materials discovery and optimization and phase-diagram mapping. Analogous to integrated circuit chips, integrated materials chips containing thousands of discrete different compositions or continuous phase diagrams, often in the form of high-quality epitaxial thin films, can be fabricated and screened for interesting properties. Microspot x-ray method, various optical measurement techniques, and a novel evanescent microwave microscope have been used to characterize the structural, optical, magnetic, and electrical properties of samples on the materials chips. These techniques are routinely used to discover/optimize and map phase diagrams of ferroelectric, dielectric, optical, magnetic, and superconducting materials.
Toward of a highly integrated probe for improving wireless network quality
NASA Astrophysics Data System (ADS)
Ding, Fei; Song, Aiguo; Wu, Zhenyang; Pan, Zhiwen; You, Xiaohu
2016-10-01
Quality of service and customer perception is the focus of the telecommunications industry. This paper proposes a low-cost approach to the acquisition of terminal data, collected from LTE networks with the application of a soft probe, based on the Java language. The soft probe includes support for fast call in the form of a referenced library, and can be integrated into various Android-based applications to automatically monitor any exception event in the network. Soft probe-based acquisition of terminal data has the advantages of low cost and can be applied on large scale. Experiment shows that a soft probe can efficiently obtain terminal network data. With this method, the quality of service of LTE networks can be determined from acquired wireless data. This work contributes to efficient network optimization, and the analysis of abnormal network events.
NASA Astrophysics Data System (ADS)
Shi, Bei; Li, Qiang; Lau, Kei May
2018-05-01
Monolithic integration of InP on a Si platform ideally facilitates on-chip light sources in silicon photonic applications. In addition to the well-developed hybrid bonding techniques, the direct epitaxy method is spawning as a more strategic and potentially cost-effective approach to monolithically integrate InP-based telecom lasers. To minimize the unwanted defects within the InP crystal, we explore multiple InAs/InP quantum dots as dislocation filters. The high quality InP buffer is thus obtained, and the dislocation filtering effects of the quantum dots are directly examined via both plan-view and cross-sectional transmission electron microscopy, along with room-temperature photoluminescence. The defect density on the InP surface was reduced to 3 × 108/cm2, providing an improved optical property of active photonic devices on Si substrates. This work offers a novel solution to advance large-scale integration of InP on Si, which is beneficial to silicon-based long-wavelength lasers in telecommunications.
Importance of a midterm time horizon for addressing ethical issues integral to nanobiotechnology.
Khushf, George
2007-01-01
There is a consensus emerging on the importance of upstream ethical engagement in nanobiotechnology. Such a preventive ethic would anticipate downstream concerns that might arise and mitigate them as part of the research and development process. However, there is an unappreciated tension between the time horizon of upstream ethics and that assumed by most bioethical research. Current standards of high-quality research on ethical issues biases the research in favor of near-term, science-based, results-oriented work. A near-term focus would miss many of the important ethical issues integral to nanobiotechnology and undermine the goals integral to upstream ethical engagement. However, if we move to a far-term time horizon, the ethical debates tend to get too speculative and are no longer disciplined by existing research trajectories. This paper addresses the link between the midterm time horizon necessary for upstream ethics and the form, content, and style of ethical reflection. New paradigm cases, standards, and criteria will be needed for high-quality upstream ethics work in the area of nanobiotechnology.
Geoinformatics 2008 - Data to Knowledge
Brady, Shailaja R.; Sinha, A. Krishna; Gundersen, Linda C.
2008-01-01
Geoinformatics is the term used to describe a variety of efforts to promote collaboration between the computer sciences and the geosciences to solve complex scientific questions. It refers to the distributed, integrated digital information system and working environment that provides innovative means for the study of the Earth systems, as well as other planets, through use of advanced information technologies. Geoinformatics activities range from major research and development efforts creating new technologies to provide high-quality, sustained production-level services for data discovery, integration and analysis, to small, discipline-specific efforts that develop earth science data collections and data analysis tools serving the needs of individual communities. The ultimate vision of Geoinformatics is a highly interconnected data system populated with high quality, freely available data, as well as, a robust set of software for analysis, visualization, and modeling. This volume is a collection of extended abstracts for oral papers presented at the Geoinformatics 2008 conference, June 11 and 13, 2008, in Potsdam, Germany.
Chen, Zhao-hua; Wu, Hai-yan; Chen, Ke-liang; Chen, Qing-hui; Wu, Ji-chun; Zhang, Jing-fei
2011-07-01
Based on the integrated assessment methods of ecological quality status (EcoQS) in coastal waters abroad as well as the domestic related research status, 11 indices were selected from the biotic and physicochemical elements of water and sediment to built an integrated EcoQS assessment index system, and, with the comprehensive consideration of domestic and international evaluation standards, 5 levels of EcoQS classified as "high, good, moderate, poor, and bad" were determined. Then, an integrated assessment method of EcoQS in coastal waters was established by using analytic hierarchy process (AHP) and fuzzy mathematics method, and tested by the analysis of the correlations between the EcoQS grade and the major anthropogenic disturbances and pollutant concentrations of Tong' an Bay. The EcoQS of Tong' an Bay was assessed as moderate, i.e., the Bay was moderately disturbed and in transitional to poor status. The established integrated assessment method could not only reflect the major anthropogenic environmental pressure and risk factors, but also give an early warning of the pollutants satisfied by law in the study area.
A new plan quality index for nasopharyngeal cancer SIB IMRT.
Jin, X; Yi, J; Zhou, Y; Yan, H; Han, C; Xie, C
2014-02-01
A new plan quality index integrating dosimetric and radiobiological indices was proposed to facilitate the evaluation and comparison of simultaneous integrated boost (SIB) intensity modulated radiotherapy (IMRT) plans for nasopharyngeal cancer (NPC) patients. Ten NPC patients treated by SIB-IMRT were enrolled in the study. Custom software was developed to read dose-volume histogram (DVH) curves from the treatment planning system (TPS). A plan filtering matrix was introduced to filter plans that fail to satisfy treatment protocol. Target plan quality indices and organ at risk (OAR) plan quality indices were calculated for qualified plans. A unique composite plan quality index (CPQI) was proposed based on the relative weight of these indices to evaluate and compare competing plans. Plan ranking results were compared with detailed statistical analysis, radiation oncology quality system (ROQS) scoring results and physician's evaluation results to verify the accuracy of this new plan quality index. The average CPQI values for plans with OAR priority of low, normal, high, and PTV only were 0.22 ± 0.08, 0.49 ± 0.077, 0.71 ± 0.062, and -0.21 ± 0.16, respectively. There were significant differences among these plan quality indices (One-way ANOVA test, p < 0.01). This was consistent with statistical analysis, ROQS results and physician's ranking results in which 90% OAR high plans were selected. Plan filtering matrix was able to speed up the plan evaluation process. The new matrix plan quality index CPQI showed good consistence with physician ranking results. It is a promising index for NPC SIB-IMRT plan evaluation. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Environmental quality of transitional waters: the lagoon of Venice case study.
Micheletti, C; Gottardo, S; Critto, A; Chiarato, S; Marcomini, A
2011-01-01
The health status of European aquatic environments, including transitional waters such as coastal lagoons, is regulated by the Water Framework Directive (WFD), which requires the classification of the water bodies' environmental quality and the achievement of a good ecological status by 2015. In the Venice lagoon, a transitional water body located in the northeastern part of Italy, the achievement of a good ecological status is hampered by several anthropogenic and natural pressures, such as sediment and water chemical contamination, and sediment erosion. In order to evaluate the lagoon's environmental quality according to the WFD (i.e. 5 quality classes, from High to Bad), an integrated Weight-of-Evidence methodology was developed and applied to classify the quality of the lagoon water bodies, integrating biological, physico-chemical, chemical, ecotoxicological, and hydromorphological data (i.e. Lines of Evidence, LOE). The quality assessment was carried out in two lagoon habitat typologies (previously defined on the basis of morphological, sediment, and hydrodynamic characteristics) which were selected taking into account the ecological gradient from sea to land, and the differences in anthropogenic pressure and contamination levels. The LOE classification was carried out by using indicators scored by comparing site specific conditions to reference conditions measured in lagoon reference sites, or provided by local, national or European regulations (e.g. Environmental Quality Standards, EQS, for chemicals). Finally, the overall quality status for each water body was calculated by a probabilistic approach, i.e. by reporting the final result as the frequency distribution of quality classes. The developed procedure was applied by using data and information concerning selected LOE and collected from monitoring programs and research studies carried out in the last 15 years in the lagoon of Venice. A set of sampling stations characterized by spatially and temporally coherent information for each LOE was selected, and among these stations, potential reference sites for each water body typology were identified. The quality assessment highlighted that there are specific lagoon areas, especially those located near the industrially developed area, which are highly affected by anthropogenic activities, and that chemical contamination is one of the main pressures affecting ecological status (e.g. macro-benthonic biodiversity) in the Venice lagoon. The integrated quality assessment procedure that was developed provided a new tool supporting decision making, as well as lagoon assessment and management. Copyright © 2010 Elsevier Ltd. All rights reserved.
An integrated multiscale river basin observing system in the Heihe River Basin, northwest China
NASA Astrophysics Data System (ADS)
Li, X.; Liu, S.; Xiao, Q.; Ma, M.; Jin, R.; Che, T.
2015-12-01
Using the watershed as the unit to establish an integrated watershed observing system has been an important trend in integrated eco-hydrologic studies in the past ten years. Thus far, a relatively comprehensive watershed observing system has been established in the Heihe River Basin, northwest China. In addition, two comprehensive remote sensing hydrology experiments have been conducted sequentially in the Heihe River Basin, including the Watershed Allied Telemetry Experimental Research (WATER) (2007-2010) and the Heihe Watershed Allied Telemetry Experimental Research (HiWATER) (2012-2015). Among these two experiments, an important result of WATER has been the generation of some multi-scale, high-quality comprehensive datasets, which have greatly supported the development, improvement and validation of a series of ecological, hydrological and quantitative remote-sensing models. The goal of a breakthrough for solving the "data bottleneck" problem has been achieved. HiWATER was initiated in 2012. This project has established a world-class hydrological and meteorological observation network, a flux measurement matrix and an eco-hydrological wireless sensor network. A set of super high-resolution airborne remote-sensing data has also been obtained. In addition, there has been important progress with regard to the scaling research. Furthermore, the automatic acquisition, transmission, quality control and remote control of the observational data has been realized through the use of wireless sensor network technology. The observation and information systems have been highly integrated, which will provide a solid foundation for establishing a research platform that integrates observation, data management, model simulation, scenario analysis and decision-making support to foster 21st-century watershed science in China.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fix, N. J.
The scope of the Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project) is to provide technical and integration support to Fluor Hanford, Inc., including operable unit investigations at 300-FF-5 and other groundwater operable units, strategic integration, technical integration and assessments, remediation decision support, and science and technology. This Quality Assurance Management Plan provides the quality assurance requirements and processes that will be followed by the Fluor Hanford, Inc. Groundwater and Technical Integration Support (Master Project).
Integrating palliative care into the trajectory of cancer care
Hui, David; Bruera, Eduardo
2016-01-01
Over the past five decades, palliative care has evolved from serving patients at the end of life into a highly specialized discipline focused on delivering supportive care to patients with life-limiting illnesses throughout the disease trajectory. A growing body of evidence is now available to inform the key domains in the practice of palliative care, including symptom management, psychosocial care, communication, decision-making, and end-of-life care. Findings from multiple studies indicate that integrating palliative care early in the disease trajectory can result in improvements in quality of life, symptom control, patient and caregiver satisfaction, quality of end-of-life care, survival, and costs of care. In this narrative Review, we discuss various strategies to integrate oncology and palliative care by optimizing clinical infrastructures, processes, education, and research. The goal of integration is to maximize patient access to palliative care and, ultimately, to improve patient outcomes. We provide a conceptual model for the integration of supportive and/or palliative care with primary and oncological care. We end by discussing how health-care systems and institutions need to tailor integration based on their resources, size, and the level of primary palliative care available. PMID:26598947
NASA Astrophysics Data System (ADS)
Xu, Bing; Du, Wen-Qiang; Li, Jia-Wen; Hu, Yan-Lei; Yang, Liang; Zhang, Chen-Chu; Li, Guo-Qiang; Lao, Zhao-Xin; Ni, Jin-Cheng; Chu, Jia-Ru; Wu, Dong; Liu, Su-Ling; Sugioka, Koji
2016-01-01
High efficiency fabrication and integration of three-dimension (3D) functional devices in Lab-on-a-chip systems are crucial for microfluidic applications. Here, a spatial light modulator (SLM)-based multifoci parallel femtosecond laser scanning technology was proposed to integrate microstructures inside a given ‘Y’ shape microchannel. The key novelty of our approach lies on rapidly integrating 3D microdevices inside a microchip for the first time, which significantly reduces the fabrication time. The high quality integration of various 2D-3D microstructures was ensured by quantitatively optimizing the experimental conditions including prebaking time, laser power and developing time. To verify the designable and versatile capability of this method for integrating functional 3D microdevices in microchannel, a series of microfilters with adjustable pore sizes from 12.2 μm to 6.7 μm were fabricated to demonstrate selective filtering of the polystyrene (PS) particles and cancer cells with different sizes. The filter can be cleaned by reversing the flow and reused for many times. This technology will advance the fabrication technique of 3D integrated microfluidic and optofluidic chips.
Mixed methods research in music therapy research.
Bradt, Joke; Burns, Debra S; Creswell, John W
2013-01-01
Music therapists have an ethical and professional responsibility to provide the highest quality care possible to their patients. Much of the time, high quality care is guided by evidence-based practice standards that integrate the most current, available research in making decisions. Accordingly, music therapists need research that integrates multiple ways of knowing and forms of evidence. Mixed methods research holds great promise for facilitating such integration. At this time, there have not been any methodological articles published on mixed methods research in music therapy. The purpose of this article is to introduce mixed methods research as an approach to address research questions relevant to music therapy practice. This article describes the core characteristics of mixed methods research, considers paradigmatic issues related to this research approach, articulates major challenges in conducting mixed methods research, illustrates four basic designs, and provides criteria for evaluating the quality of mixed methods articles using examples of mixed methods research from the music therapy literature. Mixed methods research offers unique opportunities for strengthening the evidence base in music therapy. Recommendations are provided to ensure rigorous implementation of this research approach.
NASA Technical Reports Server (NTRS)
Tabib-Azar, M.; Akinwande, D.; Ponchak, George E.; LeClair, S. R.
1999-01-01
In this article we report the design, fabrication, and characterization of very high quality factor 10 GHz microstrip resonators on high-resistivity (high-rho) silicon substrates. Our experiments show that an external quality factor of over 13 000 can be achieved on microstripline resonators on high-rho silicon substrates. Such a high Q factor enables integration of arrays of previously reported evanescent microwave probe (EMP) on silicon cantilever beams. We also demonstrate that electron-hole pair recombination and generation lifetimes of silicon can be conveniently measured by illuminating the resonator using a pulsed light. Alternatively, the EMP was also used to nondestructively monitor excess carrier generation and recombination process in a semiconductor placed near the two-dimensional resonator.
Rapid underway profiling of water quality in Queensland estuaries.
Hodge, Jonathan; Longstaff, Ben; Steven, Andy; Thornton, Phillip; Ellis, Peter; McKelvie, Ian
2005-01-01
We present an overview of a portable underway water quality monitoring system (RUM-Rapid Underway Monitoring), developed by integrating several off-the-shelf water quality instruments to provide rapid, comprehensive, and spatially referenced 'snapshots' of water quality conditions. We demonstrate the utility of the system from studies in the Northern Great Barrier Reef (Daintree River) and the Moreton Bay region. The Brisbane dataset highlights RUM's utility in characterising plumes as well as its ability to identify the smaller scale structure of large areas. RUM is shown to be particularly useful when measuring indicators with large small-scale variability such as turbidity and chlorophyll-a. Additionally, the Daintree dataset shows the ability to integrate other technologies, resulting in a more comprehensive analysis, whilst sampling offshore highlights some of the analytical issues required for sampling low concentration data. RUM is a low cost, highly flexible solution that can be modified for use in any water type, on most vessels and is only limited by the available monitoring technologies.
High quality factor GaAs-based photonic crystal microcavities by epitaxial re-growth.
Prieto, Ivan; Herranz, Jesús; Wewior, Lukasz; González, Yolanda; Alén, Benito; González, Luisa; Postigo, Pablo A
2013-12-16
We investigate L7 photonic crystal microcavities (PCMs) fabricated by epitaxial re-growth of GaAs pre-patterned substrates, containing InAs quantum dots. The resulting PCMs show hexagonal shaped nano-holes due to the development of preferential crystallographic facets during the re-growth step. Through a careful control of the fabrication processes, we demonstrate that the photonic modes are preserved throughout the process. The quality factor (Q) of the photonic modes in the re-grown PCMs strongly depends on the relative orientation between photonic lattice and crystallographic directions. The optical modes of the re-grown PCMs preserve the linear polarization and, for the most favorable orientation, a 36% of the Q measured in PCMs fabricated by the conventional procedure is observed, exhibiting values up to ~6000. The results aim to the future integration of site-controlled QDs with high-Q PCMs for quantum photonics and quantum integrated circuits.
Chuang, Emmeline; Dill, Janette; Morgan, Jennifer Craft; Konrad, Thomas R
2012-01-01
Objective To identify high-performance work practices (HPWP) associated with high frontline health care worker (FLW) job satisfaction and perceived quality of care. Methods Cross-sectional survey data from 661 FLWs in 13 large health care employers were collected between 2007 and 2008 and analyzed using both regression and fuzzy-set qualitative comparative analysis. Principal Findings Supervisor support and team-based work practices were identified as necessary for high job satisfaction and high quality of care but not sufficient to achieve these outcomes unless implemented in tandem with other HPWP. Several configurations of HPWP were associated with either high job satisfaction or high quality of care. However, only one configuration of HPWP was sufficient for both: the combination of supervisor support, performance-based incentives, team-based work, and flexible work. These findings were consistent even after controlling for FLW demographics and employer type. Additional research is needed to clarify whether HPWP have differential effects on quality of care in direct care versus administrative workers. Conclusions High-performance work practices that integrate FLWs in health care teams and provide FLWs with opportunities for participative decision making can positively influence job satisfaction and perceived quality of care, but only when implemented as bundles of complementary policies and practices. PMID:22224858
Opto-electronic oscillator: moving toward solutions based on polymer materials
NASA Astrophysics Data System (ADS)
Nguyên, Lâm Duy; Journet, Bernard; Zyss, Joseph
2008-02-01
Optoelectronic oscillators have been studied since many years now, their high spectral purity being one of their most interesting quality for photonics signal processing, communication or radio over fiber systems. One part of the structure is a long fiber optic feedback loop acting as a delay line. Different techniques have been introduced such as multiple loops in order to get very narrow spectral lines and large mode spacing. One of the problems due to long fiber loops is the size and the requirement of temperature control. In order to go toward integrated solutions it is also possible to introduce optical resonators instead of a delay line structure (as for classical electronic oscillators). But such resonators should present very high quality factor. In this paper we demonstrate solutions using resonators based on polymer materials such as PMMA-DCM. Structures such as micro-rings, micro-disks or stadium-shaped resonator have been realized at the laboratory. Quality factor of 6000 have already been achieved leading to an equivalent fiber loop of 19 m for an oscillator at 10 GHz. But it has been already theoretically proved that quality factor greater than one thousand hundred could be obtained. These resonators can be directly implemented with Mach-Zehnder optical modulators based on electro-optic polymer such as PMMA-DR1 leading to integrated solutions. And in the future it should be also possible to add a laser made with polymer material, with a structure as stadium-shape polymer micro-laser. The fully integrated photonic chip is not so far. The last important function to be implemented is the tuning of the oscillation frequency.
NASA Astrophysics Data System (ADS)
Honti, Mark; Schuwirth, Nele; Rieckermann, Jörg; Stamm, Christian
2017-03-01
The design and evaluation of solutions for integrated surface water quality management requires an integrated modelling approach. Integrated models have to be comprehensive enough to cover the aspects relevant for management decisions, allowing for mapping of larger-scale processes such as climate change to the regional and local contexts. Besides this, models have to be sufficiently simple and fast to apply proper methods of uncertainty analysis, covering model structure deficits and error propagation through the chain of sub-models. Here, we present a new integrated catchment model satisfying both conditions. The conceptual iWaQa
model was developed to support the integrated management of small streams. It can be used to predict traditional water quality parameters, such as nutrients and a wide set of organic micropollutants (plant and material protection products), by considering all major pollutant pathways in urban and agricultural environments. Due to its simplicity, the model allows for a full, propagative analysis of predictive uncertainty, including certain structural and input errors. The usefulness of the model is demonstrated by predicting future surface water quality in a small catchment with mixed land use in the Swiss Plateau. We consider climate change, population growth or decline, socio-economic development, and the implementation of management strategies to tackle urban and agricultural point and non-point sources of pollution. Our results indicate that input and model structure uncertainties are the most influential factors for certain water quality parameters. In these cases model uncertainty is already high for present conditions. Nevertheless, accounting for today's uncertainty makes management fairly robust to the foreseen range of potential changes in the next decades. The assessment of total predictive uncertainty allows for selecting management strategies that show small sensitivity to poorly known boundary conditions. The identification of important sources of uncertainty helps to guide future monitoring efforts and pinpoints key indicators, whose evolution should be closely followed to adapt management. The possible impact of climate change is clearly demonstrated by water quality substantially changing depending on single climate model chains. However, when all climate trajectories are combined, the human land use and management decisions have a larger influence on water quality against a time horizon of 2050 in the study.
Li, Yeqing; Yan, Fang; Li, Tao; Zhou, Ying; Jiang, Hao; Qian, Mingyu; Xu, Quan
2018-02-01
In this study, an integrated process was developed to produce methane and high-quality bio-briquette (BB) using corn straw (CS) through high-solid anaerobic digestion (HS-AD). CS was anaerobic digested by using a leach bed reactor at four leachate recirculation strategies. After digesting for 28 days, highest methane yield of 179.6 mL/g-VS, which was corresponded to energy production of 5.55 MJ/kg-CS, was obtained at a higher initial recirculation rate of 32 L-leachate per day. Compared with bio-briquette manufactured from raw CS and lignite, the compressive, immersion and falling strength properties of bio-briquette made from AD-treated CS (solid digestate) and lignite were significantly improved. A preferred BB can be obtained with side compressive strength of 863.8 ± 10.8 N and calorific value of 20.21 MJ/kg-BB. The finding of this study indicated that the integrated process could be an alternative way to produce methane and high-quality BB with CS. Copyright © 2017 Elsevier Ltd. All rights reserved.
Schuh, Christian; de Bruin, Jeroen S; Seeling, Walter
2015-12-01
The Allgemeines Krankenhaus Informations Management (AKIM) project was started at the Vienna General Hospital (VGH) several years ago. This led to the introduction of a new hospital information system (HIS), and the installation of the expert system platform (EXP) for the integration of Arden-Syntax-based clinical decision support systems (CDSSs). In this report we take a look at the milestones achieved and the challenges faced in the creation and modification of CDSSs, and their integration into the HIS over the last three years. We introduce a three-stage development method, which is followed in nearly all CDSS projects at the Medical University of Vienna and the VGH. Stage one comprises requirements engineering and system conception. Stage two focuses on the implementation and testing of the system. Finally, stage three describes the deployment and integration of the system in the VGH HIS. The HIS provides a clinical work environment for healthcare specialists using customizable graphical interfaces known as parametric medical documents. Multiple Arden Syntax servers are employed to host and execute the CDSS knowledge bases: two embedded in the EXP for production and development, and a further three in clinical routine for production, development, and quality assurance. Three systems are discussed; the systems serve different purposes in different clinical areas, but are all implemented with Arden Syntax. MONI-ICU is an automated surveillance system for monitoring healthcare-associated infections in the intensive care setting. TSM-CDS is a CDSS used for risk prediction in the formation of cutaneous melanoma metastases. Finally, TacroDS is a CDSS for the manipulation of dosages for tacrolimus, an immunosuppressive agent used after kidney transplantation. Problems in development and integration were related to data quality or availability, although organizational difficulties also caused delays in development and integration. Since the inception of the AKIM project at the VGH and its ability to support standards such as Arden Syntax and integrate CDSSs into clinical routine, the clinicians' interest in, and demand for, decision support has increased substantially. The use of Arden Syntax as a standard for CDSSs played a substantial role in the ability to rapidly create high-quality CDSS systems, whereas the ability to integrate these systems into the HIS made CDSSs more popular among physicians. Despite these successes, challenges such as lack of (consistent and high-quality) electronic data, social acceptance among healthcare personnel, and legislative issues remain. These have to be addressed effectively before CDSSs can be more widely accepted and adopted. Copyright © 2015 Elsevier B.V. All rights reserved.
Ragsdale, R.; Vowinkel, E.; Porter, D.; Hamilton, P.; Morrison, R.; Kohut, J.; Connell, B.; Kelsey, H.; Trowbridge, P.
2011-01-01
The Integrated Ocean Observing System (IOOS??) Regional Associations and Interagency Partners hosted a water quality workshop in January 2010 to discuss issues of nutrient enrichment and dissolved oxygen depletion (hypoxia), harmful algal blooms (HABs), and beach water quality. In 2007, the National Water Quality Monitoring Council piloted demonstration projects as part of the National Water Quality Monitoring Network (Network) for U.S. Coastal Waters and their Tributaries in three IOOS Regional Associations, and these projects are ongoing. Examples of integrated science-based solutions to water quality issues of major concern from the IOOS regions and Network demonstration projects are explored in this article. These examples illustrate instances where management decisions have benefited from decision-support tools that make use of interoperable data. Gaps, challenges, and outcomes are identified, and a proposal is made for future work toward a multiregional water quality project for beach water quality.
Maesawa, Satoshi; Fujii, Masazumi; Nakahara, Norimoto; Watanabe, Tadashi; Saito, Kiyoshi; Kajita, Yasukazu; Nagatani, Tetsuya; Wakabayashi, Toshihiko; Yoshida, Jun
2009-08-01
Initial experiences are reviewed in an integrated operation theater equipped with an intraoperative high-field (1.5 T) magnetic resonance (MR) imager and neuro-navigation (BrainSUITE), to evaluate the indications and limitations. One hundred consecutive cases were treated, consisting of 38 gliomas, 49 other tumors, 11 cerebrovascular diseases, and 2 functional diseases. The feasibility and usefulness of the integrated theater were evaluated for individual diseases, focusing on whether intraoperative images (including diffusion tensor imaging) affected the surgical strategy. The extent of resection and outcomes in each histological category of brain tumors were examined. Intraoperative high-field MR imaging frequently affected or modified the surgical strategy in the glioma group (27/38 cases, 71.1%), but less in the other tumor group (13/49 cases, 26.5%). The surgical strategy was not modified in cerebrovascular or functional diseases, but the success of procedures and the absence of complications could be confirmed. In glioma surgery, subtotal or greater resection was achieved in 22 of the 31 patients (71%) excluding biopsies, and intraoperative images revealed tumor remnants resulting in the extension of resection in 21 of the 22 patients (95.4%), the highest rate of extension among all types of pathologies. The integrated neuro-navigation improved workflow. The best indication for intraoperative high-field MR imaging and integrated neuro-navigation is brain tumors, especially gliomas, and is supplementary in assuring quality in surgery for cerebrovascular or functional diseases. Immediate quality assurance is provided in several types of neurosurgical procedures.
An approach to integrate the human vision psychology and perception knowledge into image enhancement
NASA Astrophysics Data System (ADS)
Wang, Hui; Huang, Xifeng; Ping, Jiang
2009-07-01
Image enhancement is very important image preprocessing technology especially when the image is captured in the poor imaging condition or dealing with the high bits image. The benefactor of image enhancement either may be a human observer or a computer vision process performing some kind of higher-level image analysis, such as target detection or scene understanding. One of the main objects of the image enhancement is getting a high dynamic range image and a high contrast degree image for human perception or interpretation. So, it is very necessary to integrate either empirical or statistical human vision psychology and perception knowledge into image enhancement. The human vision psychology and perception claims that humans' perception and response to the intensity fluctuation δu of visual signals are weighted by the background stimulus u, instead of being plainly uniform. There are three main laws: Weber's law, Weber- Fechner's law and Stevens's Law that describe this phenomenon in the psychology and psychophysics. This paper will integrate these three laws of the human vision psychology and perception into a very popular image enhancement algorithm named Adaptive Plateau Equalization (APE). The experiments were done on the high bits star image captured in night scene and the infrared-red image both the static image and the video stream. For the jitter problem in the video stream, this algorithm reduces this problem using the difference between the current frame's plateau value and the previous frame's plateau value to correct the current frame's plateau value. Considering the random noise impacts, the pixel value mapping process is not only depending on the current pixel but the pixels in the window surround the current pixel. The window size is usually 3×3. The process results of this improved algorithms is evaluated by the entropy analysis and visual perception analysis. The experiments' result showed the improved APE algorithms improved the quality of the image, the target and the surrounding assistant targets could be identified easily, and the noise was not amplified much. For the low quality image, these improved algorithms augment the information entropy and improve the image and the video stream aesthetic quality, while for the high quality image they will not debase the quality of the image.
Artificial neural network modeling of the water quality index using land use areas as predictors.
Gazzaz, Nabeel M; Yusoff, Mohd Kamil; Ramli, Mohammad Firuz; Juahir, Hafizan; Aris, Ahmad Zaharin
2015-02-01
This paper describes the design of an artificial neural network (ANN) model to predict the water quality index (WQI) using land use areas as predictors. Ten-year records of land use statistics and water quality data for Kinta River (Malaysia) were employed in the modeling process. The most accurate WQI predictions were obtained with the network architecture 7-23-1; the back propagation training algorithm; and a learning rate of 0.02. The WQI forecasts of this model had significant (p < 0.01), positive, very high correlation (ρs = 0.882) with the measured WQI values. Sensitivity analysis revealed that the relative importance of the land use classes to WQI predictions followed the order: mining > rubber > forest > logging > urban areas > agriculture > oil palm. These findings show that the ANNs are highly reliable means of relating water quality to land use, thus integrating land use development with river water quality management.
Certification of production-quality gLite Job Management components
NASA Astrophysics Data System (ADS)
Andreetto, P.; Bertocco, S.; Capannini, F.; Cecchi, M.; Dorigo, A.; Frizziero, E.; Giacomini, F.; Gianelle, A.; Mezzadri, M.; Molinari, E.; Monforte, S.; Prelz, F.; Rebatto, D.; Sgaravatto, M.; Zangrando, L.
2011-12-01
With the advent of the recent European Union (EU) funded projects aimed at achieving an open, coordinated and proactive collaboration among the European communities that provide distributed computing services, more strict requirements and quality standards will be asked to middleware providers. Such a highly competitive and dynamic environment, organized to comply a business-oriented model, has already started pursuing quality criteria, thus requiring to formally define rigorous procedures, interfaces and roles for each step of the software life-cycle. This will ensure quality-certified releases and updates of the Grid middleware. In the European Middleware Initiative (EMI), the release management for one or more components will be organized into Product Team (PT) units, fully responsible for delivering production ready, quality-certified software and for coordinating each other to contribute to the EMI release as a whole. This paper presents the certification process, with respect to integration, installation, configuration and testing, adopted at INFN by the Product Team responsible for the gLite Web-Service based Computing Element (CREAM CE) and for the Workload Management System (WMS). The used resources, the testbeds layout, the integration and deployment methods, the certification steps to provide feedback to developers and to grant quality results are described.
Weinstein, Dana; Bhave, Sunil A
2010-04-14
This paper introduces the resonant body transistor (RBT), a silicon-based dielectrically transduced nanoelectromechanical (NEM) resonator embedding a sense transistor directly into the resonator body. Combining the benefits of FET sensing with the frequency scaling capabilities and high quality factors (Q) of internal dielectrically transduced bar resonators, the resonant body transistor achieves >10 GHz frequencies and can be integrated into a standard CMOS process for on-chip clock generation, high-Q microwave circuits, fundamental quantum-state preparation and observation, and high-sensitivity measurements. An 11.7 GHz bulk-mode RBT is demonstrated with a quality factor Q of 1830, marking the highest frequency acoustic resonance measured to date on a silicon wafer.
John W. Sinton
1979-01-01
The first purpose of this study was to deter-mine the visual quality of New Jersey Pine Barrens forests according to residents of the area. The goal of the study was to determine how to manage Pine Barrens forests to obtain high visual quality within the framework of residents' preferences, available by the Federal Omnibus Parks Acts of 1978 and proposed New...
Martínez-Bartolomé, Salvador; Medina-Aunon, J Alberto; López-García, Miguel Ángel; González-Tejedo, Carmen; Prieto, Gorka; Navajas, Rosana; Salazar-Donate, Emilio; Fernández-Costa, Carolina; Yates, John R; Albar, Juan Pablo
2018-04-06
Mass-spectrometry-based proteomics has evolved into a high-throughput technology in which numerous large-scale data sets are generated from diverse analytical platforms. Furthermore, several scientific journals and funding agencies have emphasized the storage of proteomics data in public repositories to facilitate its evaluation, inspection, and reanalysis. (1) As a consequence, public proteomics data repositories are growing rapidly. However, tools are needed to integrate multiple proteomics data sets to compare different experimental features or to perform quality control analysis. Here, we present a new Java stand-alone tool, Proteomics Assay COMparator (PACOM), that is able to import, combine, and simultaneously compare numerous proteomics experiments to check the integrity of the proteomic data as well as verify data quality. With PACOM, the user can detect source of errors that may have been introduced in any step of a proteomics workflow and that influence the final results. Data sets can be easily compared and integrated, and data quality and reproducibility can be visually assessed through a rich set of graphical representations of proteomics data features as well as a wide variety of data filters. Its flexibility and easy-to-use interface make PACOM a unique tool for daily use in a proteomics laboratory. PACOM is available at https://github.com/smdb21/pacom .
Feasibility analysis of marine ecological on-line integrated monitoring system
NASA Astrophysics Data System (ADS)
Chu, D. Z.; Cao, X.; Zhang, S. W.; Wu, N.; Ma, R.; Zhang, L.; Cao, L.
2017-08-01
The in-situ water quality sensors were susceptible to biological attachment. Moreover, sea water corrosion and wave impact damage, and many sensors scattered distribution would cause maintenance inconvenience. The paper proposed a highly integrated marine ecological on-line integrated monitoring system, which can be used inside monitoring station. All sensors were reasonably classified, the similar in series, the overall in parallel. The system composition and workflow were described. In addition, the paper proposed attention issues of the system design and corresponding solutions. Water quality multi-parameters and 5 nutrient salts as the verification index, in-situ and systematic data comparison experiment were carried out. The results showed that the data consistency of nutrient salt, PH and salinity was better. Temperature and dissolved oxygen data trend was consistent, but the data had deviation. Turbidity fluctuated greatly; the chlorophyll trend was similar with it. Aiming at the above phenomena, three points system optimization direction were proposed.
Direct Sensor Orientation of a Land-Based Mobile Mapping System
Rau, Jiann-Yeou; Habib, Ayman F.; Kersting, Ana P.; Chiang, Kai-Wei; Bang, Ki-In; Tseng, Yi-Hsing; Li, Yu-Hua
2011-01-01
A land-based mobile mapping system (MMS) is flexible and useful for the acquisition of road environment geospatial information. It integrates a set of imaging sensors and a position and orientation system (POS). The positioning quality of such systems is highly dependent on the accuracy of the utilized POS. This limitation is the major drawback due to the elevated cost associated with high-end GPS/INS units, particularly the inertial system. The potential accuracy of the direct sensor orientation depends on the architecture and quality of the GPS/INS integration process as well as the validity of the system calibration (i.e., calibration of the individual sensors as well as the system mounting parameters). In this paper, a novel single-step procedure using integrated sensor orientation with relative orientation constraint for the estimation of the mounting parameters is introduced. A comparative analysis between the proposed single-step and the traditional two-step procedure is carried out. Moreover, the estimated mounting parameters using the different methods are used in a direct geo-referencing procedure to evaluate their performance and the feasibility of the implemented system. Experimental results show that the proposed system using single-step system calibration method can achieve high 3D positioning accuracy. PMID:22164015
GaAs photovoltaics and optoelectronics using releasable multilayer epitaxial assemblies.
Yoon, Jongseung; Jo, Sungjin; Chun, Ik Su; Jung, Inhwa; Kim, Hoon-Sik; Meitl, Matthew; Menard, Etienne; Li, Xiuling; Coleman, James J; Paik, Ungyu; Rogers, John A
2010-05-20
Compound semiconductors like gallium arsenide (GaAs) provide advantages over silicon for many applications, owing to their direct bandgaps and high electron mobilities. Examples range from efficient photovoltaic devices to radio-frequency electronics and most forms of optoelectronics. However, growing large, high quality wafers of these materials, and intimately integrating them on silicon or amorphous substrates (such as glass or plastic) is expensive, which restricts their use. Here we describe materials and fabrication concepts that address many of these challenges, through the use of films of GaAs or AlGaAs grown in thick, multilayer epitaxial assemblies, then separated from each other and distributed on foreign substrates by printing. This method yields large quantities of high quality semiconductor material capable of device integration in large area formats, in a manner that also allows the wafer to be reused for additional growths. We demonstrate some capabilities of this approach with three different applications: GaAs-based metal semiconductor field effect transistors and logic gates on plates of glass, near-infrared imaging devices on wafers of silicon, and photovoltaic modules on sheets of plastic. These results illustrate the implementation of compound semiconductors such as GaAs in applications whose cost structures, formats, area coverages or modes of use are incompatible with conventional growth or integration strategies.
Integrating multiple data sources in species distribution modeling: A framework for data fusion
Pacifici, Krishna; Reich, Brian J.; Miller, David A.W.; Gardner, Beth; Stauffer, Glenn E.; Singh, Susheela; McKerrow, Alexa; Collazo, Jaime A.
2017-01-01
The last decade has seen a dramatic increase in the use of species distribution models (SDMs) to characterize patterns of species’ occurrence and abundance. Efforts to parameterize SDMs often create a tension between the quality and quantity of data available to fit models. Estimation methods that integrate both standardized and non-standardized data types offer a potential solution to the tradeoff between data quality and quantity. Recently several authors have developed approaches for jointly modeling two sources of data (one of high quality and one of lesser quality). We extend their work by allowing for explicit spatial autocorrelation in occurrence and detection error using a Multivariate Conditional Autoregressive (MVCAR) model and develop three models that share information in a less direct manner resulting in more robust performance when the auxiliary data is of lesser quality. We describe these three new approaches (“Shared,” “Correlation,” “Covariates”) for combining data sources and show their use in a case study of the Brown-headed Nuthatch in the Southeastern U.S. and through simulations. All three of the approaches which used the second data source improved out-of-sample predictions relative to a single data source (“Single”). When information in the second data source is of high quality, the Shared model performs the best, but the Correlation and Covariates model also perform well. When the information quality in the second data source is of lesser quality, the Correlation and Covariates model performed better suggesting they are robust alternatives when little is known about auxiliary data collected opportunistically or through citizen scientists. Methods that allow for both data types to be used will maximize the useful information available for estimating species distributions.
Mirauda, Domenica; Ostoich, Marco
2018-02-23
The present study develops an integrated methodology combining the results of the water-quality classification, according to the Water Framework Directive 2000/60/EC-WFD, with those of a mathematical integrity model. It is able to analyse the potential anthropogenic impacts on the receiving water body and to help municipal decision-makers when selecting short/medium/long-term strategic mitigation actions to be performed in a territory. Among the most important causes of water-quality degradation in a river, the focus is placed on pollutants from urban wastewater. In particular, the proposed approach evaluates the efficiency and the accurate localisation of treatment plants in a basin, as well as the capacity of its river to bear the residual pollution loads after the treatment phase. The methodology is applied to a sample catchment area, located in northern Italy, where water quality is strongly affected by high population density and by the presence of agricultural and industrial activities. Nearly 10 years of water-quality data collected through official monitoring are considered for the implementation of the system. The sample basin shows different real and potential pollution conditions, according to the resilience of the river and surroundings, together with the point and diffuse pressure sources acting on the receiving body.
TOWARDS DEVELOPING INDICATORS OF SALT MARSH CONDITION
Five ecosystem services: water quality maintenance, erosion and flood control, recreation and cultural use, wildlife habitat, and food production were identified from the literature as key services to characterize salt marshes of high integrity. We describe a systems approach to ...
Efficient data management in a large-scale epidemiology research project.
Meyer, Jens; Ostrzinski, Stefan; Fredrich, Daniel; Havemann, Christoph; Krafczyk, Janina; Hoffmann, Wolfgang
2012-09-01
This article describes the concept of a "Central Data Management" (CDM) and its implementation within the large-scale population-based medical research project "Personalized Medicine". The CDM can be summarized as a conjunction of data capturing, data integration, data storage, data refinement, and data transfer. A wide spectrum of reliable "Extract Transform Load" (ETL) software for automatic integration of data as well as "electronic Case Report Forms" (eCRFs) was developed, in order to integrate decentralized and heterogeneously captured data. Due to the high sensitivity of the captured data, high system resource availability, data privacy, data security and quality assurance are of utmost importance. A complex data model was developed and implemented using an Oracle database in high availability cluster mode in order to integrate different types of participant-related data. Intelligent data capturing and storage mechanisms are improving the quality of data. Data privacy is ensured by a multi-layered role/right system for access control and de-identification of identifying data. A well defined backup process prevents data loss. Over the period of one and a half year, the CDM has captured a wide variety of data in the magnitude of approximately 5terabytes without experiencing any critical incidents of system breakdown or loss of data. The aim of this article is to demonstrate one possible way of establishing a Central Data Management in large-scale medical and epidemiological studies. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Development of optically pumped DBR-free semiconductor disk lasers (Conference Presentation)
NASA Astrophysics Data System (ADS)
Yang, Zhou; Albrecht, Alexander R.; Cederberg, Jeffrey G.; Sheik-Bahae, Mansoor
2017-03-01
Semiconductor disk lasers (SDLs) are attractive for applications requiring good beam quality, wavelength versatility, and high output powers. Typical SDLs utilize the active mirror geometry, where a semiconductor DBR is integrated with the active region by growth or post-growth bonding. This imposes restrictions for the SDL design, like material system choice, thermal management, and effective gain bandwidth. In DBR-free geometry, these restrictions can be alleviated. An integrated gain model predicts DBR-free geometry with twice the gain bandwidth of typical SDLs, which has been experimentally verified with active regions near 1 μm and 1.15 μm. The lift-off and bonding technique enables the integration of semiconductor active regions with arbitrary high quality substrates, allowing novel monolithic geometries. Bonding an active region onto a straight side of a commercial fused silica right angle prism, and attaching a high reflectivity mirror onto the hypotenuse side, with quasi CW pumping at 780 nm, lasing operation was achieved at 1037 nm with 0.2 mW average power at 1.6 mW average pump power. Laser dynamics show that thermal lens generation in the active region bottlenecks the laser efficiency. Investigations on total internal reflection based monolithic ring cavities are ongoing. These geometries would allow the intracavity integration of 2D materials or other passive absorbers, which could be relevant for stable mode locking. Unlike typical monolithic microchip SDLs, with the evanescent wave coupling technique, these monolithic geometries allow variable coupling efficiency.
NASA Astrophysics Data System (ADS)
Kolobova, Svetlana
2018-03-01
As you know, high-rise construction is an indicator of the practical implementation of advanced innovative technologies in the construction industry of the country. High-rise building inevitably comes to the big cities, in connection with the shortage and value of land. The life cycle of any construction project, including high-rise buildings consists of chains: of engineering survey - design-construction-operation. In the process of operation of a tall building, decisions about major repairs or reconstruction of a building are made for decision-making on further use. This article describes methods of assessing the consumer quality of high-rise residential buildings and the establishment of prices based on consumer characteristics of a tall residential building. It is proposed to assess the premises under their quality characteristics. The study was conducted to establish the influence of individual, comprehensive and integral indicators of comparable quality for effective quality living spaces. Simultaneously, there was established a relationship of quality with the consumer cost of housing, ultimately with the potential needs of owners, tenants of the home, lessor dwelling, or buyers of residential properties and other participants in the residential real estate market. This relationship further creates consumer requirements to quality standard of premises at a certain stage of socio-economic development.
76 FR 67429 - National Advisory Committee on Institutional Quality and Integrity (NACIQI) Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-01
... DEPARTMENT OF EDUCATION National Advisory Committee on Institutional Quality and Integrity (NACIQI) Meeting AGENCY: National Advisory Committee on Institutional Quality and Integrity, Office of... submissions comply with the requirements of Section 508 of the Rehabilitation Act, or be submitted in an...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
... DEPARTMENT OF EDUCATION National Advisory Committee on Institutional Quality and Integrity, Office of Postsecondary Education; Meeting AGENCY: National Advisory Committee on Institutional Quality and Integrity, Office of Postsecondary Education, U.S. Department of Education. ACTION: Notice of December 14-16...
NASA Technical Reports Server (NTRS)
Deckert, W. H.; Rolls, L. S.
1974-01-01
An integrated propulsion/control system for lift-fan transport aircraft is described. System behavior from full-scale experimental and piloted simulator investigations are reported. The lift-fan transport is a promising concept for short-to-medium haul civil transportation and for other missions. The lift-fan transport concept features high cruise airspeed, favorable ride qualities, small perceived noise footprints, high utilization, transportation system flexibility, and adaptability to VTOL, V/STOL, or STOL configurations. The lift-fan transport has high direct operating costs in comparison to conventional aircraft, primarily because of propulsion system and aircraft low-speed control system installation requirements. An integrated lift-fan propulsion system/aircraft low-speed control system that reduces total propulsion system and control system installation requirements is discussed.
Integrating body movement into attractiveness research.
Fink, Bernhard; Weege, Bettina; Neave, Nick; Pham, Michael N; Shackelford, Todd K
2015-01-01
People judge attractiveness and make trait inferences from the physical appearance of others, and research reveals high agreement among observers making such judgments. Evolutionary psychologists have argued that interest in physical appearance and beauty reflects adaptations that motivate the search for desirable qualities in a potential partner. Although men more than women value the physical appearance of a partner, appearance universally affects social perception in both sexes. Most studies of attractiveness perceptions have focused on third party assessments of static representations of the face and body. Corroborating evidence suggests that body movement, such as dance, also conveys information about mate quality. Here we review evidence that dynamic cues (e.g., gait, dance) also influence perceptions of mate quality, including personality traits, strength, and overall attractiveness. We recommend that attractiveness research considers the informational value of body movement in addition to static cues, to present an integrated perspective on human social perception.
An integrated approach to improving noisy speech perception
NASA Astrophysics Data System (ADS)
Koval, Serguei; Stolbov, Mikhail; Smirnova, Natalia; Khitrov, Mikhail
2002-05-01
For a number of practical purposes and tasks, experts have to decode speech recordings of very poor quality. A combination of techniques is proposed to improve intelligibility and quality of distorted speech messages and thus facilitate their comprehension. Along with the application of noise cancellation and speech signal enhancement techniques removing and/or reducing various kinds of distortions and interference (primarily unmasking and normalization in time and frequency fields), the approach incorporates optimal listener expert tactics based on selective listening, nonstandard binaural listening, accounting for short-term and long-term human ear adaptation to noisy speech, as well as some methods of speech signal enhancement to support speech decoding during listening. The approach integrating the suggested techniques ensures high-quality ultimate results and has successfully been applied by Speech Technology Center experts and by numerous other users, mainly forensic institutions, to perform noisy speech records decoding for courts, law enforcement and emergency services, accident investigation bodies, etc.
Händel, A; Jünemann, A G M; Prokosch, H-U; Beyer, A; Ganslandt, T; Grolik, R; Klein, A; Mrosek, A; Michelson, G; Kruse, F E
2009-03-01
A prerequisite for integrated care programmes is the implementation of a communication network meeting quality assurance standards. Against this background the main objective of the integrated care project between the University Eye Hospital Erlangen and the health insurance company AOK Bayern was to evaluate the potential and the acceptance of a web-based electronic patient record in the context of cataract and retinal surgery. Standardised modules for capturing pre-, intra- and post-operative data on the basis of clinical pathway guidelines for cataract- and retinal surgery have been developed. There are 6 data sets recorded per patient (1 pre-operative, 1 operative, 4-6 post-operative). For data collection, a web-based communication system (Soarian Integrated Care) has been chosen which meets the high requirements in data security, as well as being easy to handle. This teleconsultation system and the embedded electronic patient record are independent of the software used by respective offices and hospitals. Data transmission and storage were carried out in real-time. At present, 101 private ophthalmologists are taking part in the IGV contract with the University Eye Hospital Erlangen. This corresponds to 52% of all private ophthalmologists in the region. During the period from January 1st 2006 to December 31st 2006, 1844 patients were entered. Complete documentation was achieved in 1390 (75%) of all surgical procedures. For evaluation of this data, a multidimensional report and analysis tool (Cognos) was used. The deviation from target refraction as one quality indicator was in the mean 0.09 diopter. The web-based patient record used in this project was highly accepted by the private ophthalmologists. However there are still general concerns against the exchange of medical data via the internet. Nevertheless, the web-based patient record is an essential tool for a functional integration between the ambulatory and stationary health-care units. In addition to the telemedicine functions of the system, we achieved the export of the data to a data warehouse system in order to provide a flexible and powerful tool for quality assurance analysis and reporting.
Rivas-Murias, Beatriz; Manuel Vila-Fungueiriño, José; Rivadulla, Francisco
2015-01-01
Misfit cobaltates ([Bi/Ba/Sr/Ca/CoO]nRS[CoO2]q) constitute the most promising family of thermoelectric oxides for high temperature energy harvesting. However, their complex structure and chemical composition makes extremely challenging their deposition by high-vacuum physical techniques. Therefore, many of them have not been prepared as thin films until now. Here we report the synthesis of high-quality epitaxial thin films of the most representative members of this family of compounds by a water-based chemical solution deposition method. The films show an exceptional crystalline quality, with an electrical conductivity and thermopower comparable to single crystals. These properties are linked to the epitaxial matching of the rock-salt layers of the structure to the substrate, producing clean interfaces free of amorphous phases. This is an important step forward for the integration of these materials with complementary n-type thermoelectric oxides in multilayer nanostructures. PMID:26153533
Ozkosem, Burak; Feinstein, Sheldon I.; Fisher, Aron B.; O'Flaherty, Cristian
2016-01-01
Oxidative stress, the imbalance between reactive oxygen species production and antioxidant defenses, is associated with male infertility. Peroxiredoxins (PRDXs) are antioxidant enzymes with a wide distribution in spermatozoa. PRDX6 is highly abundant and located in all subcellular compartments of the spermatozoon. Infertile men have lower levels of sperm PRDX6 associated with low sperm motility and high DNA damage. In order to better understand the role of PRDX6 in male reproduction, the aim of this study was to elucidate the impact of the lack of PRDX6 on male mouse fertility. Spermatozoa lacking PRDX6 showed significantly increased levels of cellular oxidative damage evidenced by high levels of lipid peroxidation, 8-hydroxy-deoxyguanosine (DNA oxidation), and protein oxidation (S-glutathionylation and carbonylation), lower sperm chromatin quality (high DNA fragmentation and low DNA compaction, due to low levels of protamination and a high percentage of free thiols), along with decreased sperm motility and impairment of capacitation as compared with wild-type (WT) spermatozoa. These manifestations of damage are exacerbated by tert-butyl hydroperoxide treatment in vivo. While WT males partially recovered the quality of their spermatozoa (in terms of motility and sperm DNA integrity), Prdx6−/− males showed higher levels of sperm damage (lower motility and chromatin integrity) 6 mo after the end of treatment. In conclusion, Prdx6−/− males are more vulnerable to oxidative stress than WT males, resulting in impairment of sperm quality and ability to fertilize the oocyte, compatible with the subfertility phenotype observed in these knockout mice. PMID:26792942
Ozkosem, Burak; Feinstein, Sheldon I; Fisher, Aron B; O'Flaherty, Cristian
2016-03-01
Oxidative stress, the imbalance between reactive oxygen species production and antioxidant defenses, is associated with male infertility. Peroxiredoxins (PRDXs) are antioxidant enzymes with a wide distribution in spermatozoa. PRDX6 is highly abundant and located in all subcellular compartments of the spermatozoon. Infertile men have lower levels of sperm PRDX6 associated with low sperm motility and high DNA damage. In order to better understand the role of PRDX6 in male reproduction, the aim of this study was to elucidate the impact of the lack of PRDX6 on male mouse fertility. Spermatozoa lacking PRDX6 showed significantly increased levels of cellular oxidative damage evidenced by high levels of lipid peroxidation, 8-hydroxy-deoxyguanosine (DNA oxidation), and protein oxidation (S-glutathionylation and carbonylation), lower sperm chromatin quality (high DNA fragmentation and low DNA compaction, due to low levels of protamination and a high percentage of free thiols), along with decreased sperm motility and impairment of capacitation as compared with wild-type (WT) spermatozoa. These manifestations of damage are exacerbated by tert-butyl hydroperoxide treatment in vivo. While WT males partially recovered the quality of their spermatozoa (in terms of motility and sperm DNA integrity), Prdx6(-/-) males showed higher levels of sperm damage (lower motility and chromatin integrity) 6 mo after the end of treatment. In conclusion, Prdx6(-/-) males are more vulnerable to oxidative stress than WT males, resulting in impairment of sperm quality and ability to fertilize the oocyte, compatible with the subfertility phenotype observed in these knockout mice. © 2016 by the Society for the Study of Reproduction, Inc.
Nakazato, Takeru; Bono, Hidemasa
2017-01-01
Abstract It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. PMID:28449062
NASA Astrophysics Data System (ADS)
Wurm, Lothar; Gössinger, Manfred; Wendelin, Silvia; Martina, Kieler; Thomas, Rühmer; Walter, Brandes; Kathrin, Sigl
2015-04-01
Between 2006 and 2013 the old apple varieties 'Ananas Reinette', 'llzer Rosenapfel', 'Kronprinz Rudolf', 'Steirischer Maschanzker', 'Goldparmäne', 'Roter Boskoop', 'Ribston Pepping', 'Steirische Schafnase', 'Winterbananenapfel', 'Lavanttaler Bananenapfel', 'Himbeerapfel' and 'Florianer Rosmarin' (from 2009 on also 'Roter Berlepsch', 'Cox Orange' and 'Kanada Reinette') were tested for their fresh market suitability at the experimental orchard Haschhof of the HBLA and BA für Wein- und Obstbau Klosterneuburg under organic and integrated cultivation (IP) conditions trained as slender spindle. In 2010 the effect of an organic and a combined "integrated-organic summer" plant protection strategie on fruit quality and pesticide residues was tested in addition. No pesticide residues were detected in fruits of both plant protection strategies, expect on fruits of "integrated-organic summer" Schafnase in 2010. At harvest 2010 the bio-variant showed a significantly higher percentage of fruits with skin defects. The losses due to parasitic diseases during storage were strongly depending on the cultivar, but hardly affected by the plant protection strategy in this year. Looking at the entire experimental period, most of the varieties in the organic plot showed a comparable fruiting performance as those in the IP plot. The best fruiting performances were found with 'Winterbananenapfel', 'Roter Boskoop' and 'Kronprinz Rudolf', while the cumulative yield of 'Florianer Rosmarin', 'Himbeerapfel' and 'Lavanttaler Bananenapfel' remained below average. With respect to external fruit quality and storability 'Winterbananenapfel', 'Steirischer Maschanzker', 'Roter Boskoop', 'Kronprinz Rudolf' and 'Ilzer Rosenapfel' showed comparatively good results. With 'Ananas Reinette' the significantly lowest total phenolics contents were determined. 'Kanada Reinette', 'Roter Boskoop' and 'Ananas Reinette' showed a high acidity. High contents of soluble solids were found with 'Goldparmäne', 'Roter Berlepsch' and 'Ribston Pepping'. As fresh fruit 'Roter Berlepsch', 'Kronprinz Rudolf', 'Ilzer Rosenapfel', 'Ananasrenette', 'Roter Boskoop' and 'Goldparmäne' were rated the best, 'Cox Orange', 'Kronprinz Rudolf' and 'Ilzer Rosenapfel' were the best varieties for apple juice.
MAINTAINING DATA QUALITY IN THE PERFORMANCE OF A LARGE SCALE INTEGRATED MONITORING EFFORT
Macauley, John M. and Linda C. Harwell. In press. Maintaining Data Quality in the Performance of a Large Scale Integrated Monitoring Effort (Abstract). To be presented at EMAP Symposium 2004: Integrated Monitoring and Assessment for Effective Water Quality Management, 3-7 May 200...
SEEING THE LIGHT: A WATER CLARITY INDEX FOR INTEGRATED WATER QUALITY ASSESSMENTS
Smith, Lisa M. and Linda C. Harwell. In press. Seeing the Light: A Water Clarity Index for Integrated Water Quality Assessments (Abstract). To be presented at EMAP Symposium 2004: Integrated Monitoring & Assessment for Effective Water Quality Management. 1 p. (ERL,GB R970).
<...
Talboom-Kamp, Esther Pwa; Verdijk, Noortje A; Kasteleyn, Marise J; Harmans, Lara M; Talboom, Irvin Jsh; Numans, Mattijs E; Chavannes, Niels H
2017-05-31
Worldwide, nearly 3 million people die of chronic obstructive pulmonary disease (COPD) every year. Integrated disease management (IDM) improves disease-specific quality of life and exercise capacity for people with COPD, but can also reduce hospital admissions and hospital days. Self-management of COPD through eHealth interventions has shown to be an effective method to improve the quality and efficiency of IDM in several settings, but it remains unknown which factors influence usage of eHealth and change in behavior of patients. Our study, e-Vita COPD, compares different levels of integration of Web-based self-management platforms in IDM in three primary care settings. The main aim of this study is to analyze the factors that successfully promote the use of a self-management platform for COPD patients. The e-Vita COPD study compares three different approaches to incorporating eHealth via Web-based self-management platforms into IDM of COPD using a parallel cohort design. Three groups integrated the platforms to different levels. In groups 1 (high integration) and 2 (medium integration), randomization was performed to two levels of personal assistance for patients (high and low assistance); in group 3 there was no integration into disease management (none integration). Every visit to the e-Vita and Zorgdraad COPD Web platforms was tracked objectively by collecting log data (sessions and services). At the first log-in, patients completed a baseline questionnaire. Baseline characteristics were automatically extracted from the log files including age, gender, education level, scores on the Clinical COPD Questionnaire (CCQ), dyspnea scale (MRC), and quality of life questionnaire (EQ5D). To predict the use of the platforms, multiple linear regression analyses for the different independent variables were performed: integration in IDM (high, medium, none), personal assistance for the participants (high vs low), educational level, and self-efficacy level (General Self-Efficacy Scale [GSES]). All analyses were adjusted for age and gender. Of the 702 invited COPD patients, 215 (30.6%) registered to a platform. Of the 82 patients in group 1 (high integration IDM), 36 were in group 1A (personal assistance) and 46 in group 1B (low assistance). Of the 96 patients in group 2 (medium integration IDM), 44 were in group 2A (telephone assistance) and 52 in group 2B (low assistance). A total of 37 patients participated in group 3 (no integration IDM). In all, 107 users (49.8%) visited the platform at least once in the 15-month period. The mean number of sessions differed between the three groups (group 1: mean 10.5, SD 1.3; group 2: mean 8.8, SD 1.4; group 3: mean 3.7, SD 1.8; P=.01). The mean number of sessions differed between the high-assistance and low-assistance groups in groups 1 and 2 (high: mean 11.8, SD 1.3; low: mean 6.7, SD 1.4; F1,80=6.55, P=.01). High-assistance participants used more services (mean 45.4, SD 6.2) than low-assistance participants (mean 21.2, SD 6.8; F1,80=6.82, P=.01). No association was found between educational level and usage and between GSES and usage. Use of a self-management platform is higher when participants receive adequate personal assistance about how to use the platform. Blended care, where digital health and usual care are integrated, will likely lead to increased use of the online program. Future research should provide additional insights into the preferences of different patient groups. Nederlands Trial Register NTR4098; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=4098 (Archived by WebCite at http://www.webcitation.org/6qO1hqiJ1). ©Esther PWA Talboom-Kamp, Noortje A Verdijk, Marise J Kasteleyn, Lara M Harmans, Irvin JSH Talboom, Mattijs E Numans, Niels H Chavannes. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 31.05.2017.
The integration of quality function deployment and Kansei Engineering: An overview of application
NASA Astrophysics Data System (ADS)
Lokman, Anitawati Mohd; Awang, Ahmad Azran; Omar, Abdul Rahman; Abdullah, Nur Atiqah Sia
2016-02-01
As a result of today's globalized world and robust development of emerging markets, consumers are able to select from an endless number of products that are mostly similar in terms of design and properties, as well as equivalent in function and performance. The survival of businesses in a competitive ambience requires innovation, consumer loyalty, and products that are easily identifiable by consumers. Today's manufacturers have started to employ customer research instruments to survive in the highly industrialized world—for example, Conjoint Analysis, Design of Experiments and Semantic Design of Environment. However, this work only attempts to concentrate on Kansei Engineering and Quality Function Deployment. Kansei Engineering (KE) is deemed as the most appropriate method to link consumers' feelings, emotions or senses to the properties of a product because it translates people's impressions, interests, and feelings to the solutions of product design. Likewise, Quality Function Deployment (QFD) enables clearer interpretation of the needs of consumers, better concepts or products, and enhanced communication to internal operations that must then manufacture and deliver the product or services. The integration of both KE and QFD is believed possible, as many product manufacturers and businesses have started to utilize systematized methods to translate consumers' needs and wants into processes and products. Therefore, this work addresses areas of various integrations of KE and QFD processes in the industry, in an effort to assist an integration of KE and QFD. This work aims to provide evidence on the integration mechanism to enable successful incorporation of consumer's implicit feelings and demands into product quality improvement, and simultaneously providing an overview of both KE and QFD from the perspective of a novice.
Capela, R; Raimundo, J; Santos, M M; Caetano, M; Micaelo, C; Vale, C; Guimarães, L; Reis-Henriques, M A
2016-01-01
The Water Framework Directive (WFD) provides an important legislative opportunity to promote and implement an integrated approach for the protection of inland surface waters, transitional waters, coastal waters and groundwaters. The transitional waters constitute a central piece as they are usually under high environmental pressure and by their inherent characteristics present monitoring challenges. Integrating water quality monitoring with biological monitoring can increase the cost-effectiveness of monitoring efforts. One way of doing this is with biomarkers, which effectively integrate physical-chemical status and biological quality elements, dealing holistically with adverse consequences on the health of water bodies. The new Marine Strategy Framework Directive (MSFD) already incorporates the biomarker approach. Given the recent activities of OSPAR and HELCOM to harmonize existing monitoring guidelines between MSFD and WFD the use of similar methodologies should be fostered. To illustrate the potential of the biomarker approach, juveniles of flounder (Platichthys flesus) were used to evaluate the quality of the Minho river-estuary water bodies. The use of juveniles instead of adults eliminates several confounding factors such changes on the biological responses associated with reproduction. Here, a panel of well-established biomarkers, EROD, AChE, SOD, CAT, GST, LPO, ENA and FACs (1-Hydroxyrene) were selected and measured along with a gradient of different physical conditions, and integrated with trace elements characterization on both biota and sediments. In general, a clear profile along the water bodies was found, with low seasonal and spatial variation, consistent with a low impacted area. Overall, the results support the use of both the battery of biomarkers and the use of juvenile flounders in the monitoring of the water quality status within the WFD. Copyright © 2015 Elsevier B.V. All rights reserved.
Cosimi, Lisa A; Dam, Huong V; Nguyen, Thai Q; Ho, Huyen T; Do, Phuong T; Duc, Duat N; Nguyen, Huong T; Gardner, Bridget; Libman, Howard; Pollack, Todd; Hirschhorn, Lisa R
2015-07-17
The global scale-up of antiretroviral therapy included extensive training and onsite support to build the capacity of HIV health care workers. However, traditional efforts aimed at strengthening knowledge and skills often are not successful at improving gaps in the key health systems required for sustaining high quality care. We trained and mentored existing staff of the Son La provincial health department and provincial HIV clinic to work as a provincial coaching team (PCT) to provide integrated coaching in clinical HIV skills and quality improvement (QI) to the HIV clinics in the province. Nine core indicators were measured through chart extraction by clinic and provincial staff at baseline and at 6 month intervals thereafter. Coaching from the team to each of the clinics, in both QI and clinical skills, was guided by results of performance measurements, gap analyses, and resulting QI plans. After 18 months, the PCT had successfully spread QI activities, and was independently providing regular coaching to the provincial general hospital clinic and six of the eight district clinics in the province. The frequency and type of coaching was determined by performance measurement results. Clinics completed a mean of five QI projects. Quality of HIV care was improved throughout all clinics with significant increases in seven of the indicators. Overall both the PCT activities and clinic performance were sustained after integration of the model into the Vietnam National QI Program. We successfully built capacity of a team of public sector health care workers to provide integrated coaching in both clinical skills and QI across a province. The PCT is a feasible and effective model to spread and sustain quality activities and improve HIV care services in a decentralized rural setting.
Lagman, Ruth L; Walsh, Declan; LeGrand, Susan B; Davis, Mellar P
2011-03-01
The medical care of individuals with advanced disease is complex and has historically been fragmented and suboptimal. Palliative medicine attempts to address these needs. The Harry R. Horvitz Center for Palliative Medicine at the Cleveland Clinic is an established comprehensive integrated program. Structured and seamless clinical operations are important to ensure the best delivery of high-quality medical care and continuity for those affected by life-limiting illness.
Quality assurance: Importance of systems and standard operating procedures
Manghani, Kishu
2011-01-01
It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company. PMID:21584180
Quality assurance: Importance of systems and standard operating procedures.
Manghani, Kishu
2011-01-01
It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.
Literature-Based Workshops for Language Arts: Ideas for Active Learning Grades K-2.
ERIC Educational Resources Information Center
Morrison, Kathy; Dittrich, Tina
This book is intended for teachers who want to integrate high-quality children's literature into the language arts curriculum. The illustrated book provides a host of small-group workshops for children in kindergarten through second grade, planned around storybooks they love. Each workshop suggested in the book is geared to specific High/Scope…
ERIC Educational Resources Information Center
Fathurrohman, Maman; Porter, Anne
2012-01-01
Teaching and learning of mathematics are integral parts of societies throughout the world. The fundamental or core nature of mathematics, its compulsory acquisition, requires high quality mathematics learning experiences. Moreover it is highly desirable that the emergence of new technology positively influences learning experiences in mathematics.…
Medicine: business or profession?
Zhai, Xiaomei
2012-06-01
As professionals, doctors have a contractual relationship with society that trains them and confers on them exclusive power to practice medical care. In the contract, power and responsibility should be balanced. When the power is conferred by society to a profession, the profession should take responsibility for society, including the provision of high quality services, and maintain high standard principled conduct and integrity.
Next level of board accountability in health care quality.
Pronovost, Peter J; Armstrong, C Michael; Demski, Renee; Peterson, Ronald R; Rothman, Paul B
2018-03-19
Purpose The purpose of this paper is to offer six principles that health system leaders can apply to establish a governance and management system for the quality of care and patient safety. Design/methodology/approach Leaders of a large academic health system set a goal of high reliability and formed a quality board committee in 2011 to oversee quality and patient safety everywhere care was delivered. Leaders of the health system and every entity, including inpatient hospitals, home care companies, and ambulatory services staff the committee. The committee works with the management for each entity to set and achieve quality goals. Through this work, the six principles emerged to address management structures and processes. Findings The principles are: ensure there is oversight for quality everywhere care is delivered under the health system; create a framework to organize and report the work; identify care areas where quality is ambiguous or underdeveloped (i.e. islands of quality) and work to ensure there is reporting and accountability for quality measures; create a consolidated quality statement similar to a financial statement; ensure the integrity of the data used to measure and report quality and safety performance; and transparently report performance and create an explicit accountability model. Originality/value This governance and management system for quality and safety functions similar to a finance system, with quality performance documented and reported, data integrity monitored, and accountability for performance from board to bedside. To the authors' knowledge, this is the first description of how a board has taken this type of systematic approach to oversee the quality of care.
The costs and cost-effectiveness of an integrated sepsis treatment protocol.
Talmor, Daniel; Greenberg, Dan; Howell, Michael D; Lisbon, Alan; Novack, Victor; Shapiro, Nathan
2008-04-01
Sepsis is associated with high mortality and treatment costs. International guidelines recommend the implementation of integrated sepsis protocols; however, the true cost and cost-effectiveness of these are unknown. To assess the cost-effectiveness of an integrated sepsis protocol, as compared with conventional care. Prospective cohort study of consecutive patients presenting with septic shock and enrolled in the institution's integrated sepsis protocol. Clinical and economic outcomes were compared with a historical control cohort. Beth Israel Deaconess Medical Center. Overall, 79 patients presenting to the emergency department with septic shock in the treatment cohort and 51 patients in the control group. An integrated sepsis treatment protocol incorporating empirical antibiotics, early goal-directed therapy, intensive insulin therapy, lung-protective ventilation, and consideration for drotrecogin alfa and steroid therapy. In-hospital treatment costs were collected using the hospital's detailed accounting system. The cost-effectiveness analysis was performed from the perspective of the healthcare system using a lifetime horizon. The primary end point for the cost-effectiveness analysis was the incremental cost per quality-adjusted life year gained. Mortality in the treatment group was 20.3% vs. 29.4% in the control group (p = .23). Implementing an integrated sepsis protocol resulted in a mean increase in cost of approximately $8,800 per patient, largely driven by increased intensive care unit length of stay. Life expectancy and quality-adjusted life years were higher in the treatment group; 0.78 and 0.54, respectively. The protocol was associated with an incremental cost of $11,274 per life-year saved and a cost of $16,309 per quality-adjusted life year gained. In patients with septic shock, an integrated sepsis protocol, although not cost-saving, appears to be cost-effective and compares very favorably to other commonly delivered acute care interventions.
ERIC Educational Resources Information Center
Steckelberg, Marie L.; Hoadley, Michael R.; Thompson, Ray; Martin, Patricia; Bormann, Gene
2000-01-01
Introduces a research project on water quality in which students from two different high schools collaborate with university science methods students. Includes the analyses of air temperature, water temperature, fecal coliform, dissolved oxygen, phosphate level, turbidity, and pH level. Integrates biology, environmental sciences, physical…
Safe, High-Performance, Sustainable Precast School Design
ERIC Educational Resources Information Center
Finsen, Peter I.
2011-01-01
School design utilizing integrated architectural and structural precast and prestressed concrete components has gained greater acceptance recently for numerous reasons, including increasingly sophisticated owners and improved learning environments based on material benefits such as: sustainability, energy efficiency, indoor air quality, storm…
Quality assurance and management in microelectronics companies: ISO 9000 versus Six Sigma
NASA Astrophysics Data System (ADS)
Lupan, Razvan; Kobi, Abdessamad; Robledo, Christian; Bacivarov, Ioan; Bacivarov, Angelica
2009-01-01
A strategy for the implementation of the Six Sigma method as an improvement solution for the ISO 9000:2000 Quality Standard is proposed. Our approach is focused on integrating the DMAIC cycle of the Six Sigma method with the PDCA process approach, highly recommended by the standard ISO 9000:2000. The Six Sigma steps applied to each part of the PDCA cycle are presented in detail, giving some tools and training examples. Based on this analysis the authors conclude that applying Six Sigma philosophy to the Quality Standard implementation process is the best way to achieve the optimal results in quality progress and therefore in customers satisfaction.
Doña, Carolina; Chang, Ni-Bin; Caselles, Vicente; Sánchez, Juan M; Camacho, Antonio; Delegido, Jesús; Vannah, Benjamin W
2015-03-15
Lake eutrophication is a critical issue in the interplay of water supply, environmental management, and ecosystem conservation. Integrated sensing, monitoring, and modeling for a holistic lake water quality assessment with respect to multiple constituents is in acute need. The aim of this paper is to develop an integrated algorithm for data fusion and mining of satellite remote sensing images to generate daily estimates of some water quality parameters of interest, such as chlorophyll a concentrations and water transparency, to be applied for the assessment of the hypertrophic Albufera de Valencia. The Albufera de Valencia is the largest freshwater lake in Spain, which can often present values of chlorophyll a concentration over 200 mg m(-3) and values of transparency (Secchi Disk, SD) as low as 20 cm. Remote sensing data from Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat Thematic Mapper (TM) and Enhance Thematic Mapper (ETM+) images were fused to carry out an integrative near-real time water quality assessment on a daily basis. Landsat images are useful to study the spatial variability of the water quality parameters, due to its spatial resolution of 30 m, in comparison to the low spatial resolution (250/500 m) of MODIS. While Landsat offers a high spatial resolution, the low temporal resolution of 16 days is a significant drawback to achieve a near real-time monitoring system. This gap may be bridged by using MODIS images that have a high temporal resolution of 1 day, in spite of its low spatial resolution. Synthetic Landsat images were fused for dates with no Landsat overpass over the study area. Finally, with a suite of ground truth data, a few genetic programming (GP) models were derived to estimate the water quality using the fused surface reflectance data as inputs. The GP model for chlorophyll a estimation yielded a R(2) of 0.94, with a Root Mean Square Error (RMSE) = 8 mg m(-3), and the GP model for water transparency estimation using Secchi disk showed a R(2) of 0.89, with an RMSE = 4 cm. With this effort, the spatiotemporal variations of water transparency and chlorophyll a concentrations may be assessed simultaneously on a daily basis throughout the lake for environmental management. Copyright © 2014 Elsevier Ltd. All rights reserved.
Vasan, Ashwin; Ellner, Andrew; Lawn, Stephen D; Gove, Sandy; Anatole, Manzi; Gupta, Neil; Drobac, Peter; Nicholson, Tom; Seung, Kwonjune; Mabey, David C; Farmer, Paul E
2014-01-14
More than three decades after the 1978 Declaration of Alma-Ata enshrined the goal of 'health for all', high-quality primary care services remain undelivered to the great majority of the world's poor. This failure to effectively reach the most vulnerable populations has been, in part, a failure to develop and implement appropriate and effective primary care delivery models. This paper examines a root cause of these failures, namely that the inability to achieve clear and practical consensus around the scope and aims of primary care may be contributing to ongoing operational inertia. The present work also examines integrated models of care as a strategy to move beyond conceptual dissonance in primary care and toward implementation. Finally, this paper examines the strengths and weaknesses of a particular model, the World Health Organization's Integrated Management of Adolescent and Adult Illness (IMAI), and its potential as a guidepost toward improving the quality of primary care delivery in poor settings. Integration and integrated care may be an important approach in establishing a new paradigm of primary care delivery, though overall, current evidence is mixed. However, a number of successful specific examples illustrate the potential for clinical and service integration to positively impact patient care in primary care settings. One example deserving of further examination is the IMAI, developed by the World Health Organization as an operational model that integrates discrete vertical interventions into a comprehensive delivery system encompassing triage and screening, basic acute and chronic disease care, basic prevention and treatment services, and follow-up and referral guidelines. IMAI is an integrated model delivered at a single point-of-care using a standard approach to each patient based on the universal patient history and physical examination. The evidence base on IMAI is currently weak, but whether or not IMAI itself ultimately proves useful in advancing primary care delivery, it is these principles that should serve as the basis for developing a standard of integrated primary care delivery for adults and adolescents that can serve as the foundation for ongoing quality improvement. As integrated primary care is the standard of care in the developed world, so too must we move toward implementing integrated models of primary care delivery in poorer settings. Models such as IMAI are an important first step in this evolution. A robust and sustained commitment to innovation, research and quality improvement will be required if integrated primary care delivery is to become a reality in developing world.
Improvement of automatic control system for high-speed current collectors
NASA Astrophysics Data System (ADS)
Sidorov, O. A.; Goryunov, V. N.; Golubkov, A. S.
2018-01-01
The article considers the ways of regulation of pantographs to provide quality and reliability of current collection at high speeds. To assess impact of regulation was proposed integral criterion of the quality of current collection, taking into account efficiency and reliability of operation of the pantograph. The study was carried out using mathematical model of interaction of pantograph and catenary system, allowing to assess contact force and intensity of arcing at the contact zone at different movement speeds. The simulation results allowed us to estimate the efficiency of different methods of regulation of pantographs and determine the best option.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-11
... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OW-2011-0986; FRL-9617-1] EPA Workshops on Achieving Water Quality Through Integrated Municipal Stormwater and Wastewater Plans Under the Clean Water Act (CWA... integrated municipal stormwater and wastewater plans to meet the water quality objectives of the CWA. The...
High-quality RNA extraction from the sea urchin Paracentrotus lividus embryos
Ruocco, Nadia; Costantini, Susan; Zupo, Valerio; Romano, Giovanna; Ianora, Adrianna; Fontana, Angelo; Costantini, Maria
2017-01-01
The sea urchin Paracentrotus lividus (Lamarck, 1816) is a keystone herbivore in the Mediterranean Sea due to its ability to transform macroalgal-dominated communities into barren areas characterized by increased cover of bare substrates and encrusting coralline algae, reduced biodiversity and altered ecosystem functions. P. lividus is also an excellent animal model for toxicology, physiology and biology investigations having been used for more than a century as a model for embryological studies with synchronously developing embryos which are easy to manipulate and analyze for morphological aberrations. Despite its importance for the scientific community, the complete genome is still not fully annotated. To date, only a few molecular tools are available and a few Next Generation Sequencing (NGS) studies have been performed. Here we aimed at setting-up an RNA extraction method to obtain high quality and sufficient quantity of RNA for NGS from P. lividus embryos at the pluteus stage. We compared five different RNA extraction protocols from four different pools of plutei (500, 1000, 2500 and 5000 embryos): TRIzol®, and four widely-used Silica Membrane kits, GenElute™ Mammalian Total RNA Miniprep Kit, RNAqueous® Micro Kit, RNeasy® Micro Kit and Aurum™ Total RNA Mini Kit. The quantity of RNA isolated was evaluated using NanoDrop. The quality, considering the purity, was measured as A260/A280 and A260/230 ratios. The integrity was measured by RNA Integrity Number (RIN). Our results demonstrated that the most efficient procedures were GenElute, RNeasy and Aurum, producing a sufficient quantity of RNA for NGS. The Bioanalyzer profiles and RIN values revealed that the most efficient methods guaranteeing for RNA integrity were RNeasy and Aurum combined with an initial preservation in RNAlater. This research represents the first attempt to standardize a method for high-quality RNA extraction from sea urchin embryos at the pluteus stage, providing a new resource for this established model marine organism. PMID:28199408
NASA Astrophysics Data System (ADS)
Azarnova, T. V.; Titova, I. A.; Barkalov, S. A.
2018-03-01
The article presents an algorithm for obtaining an integral assessment of the quality of an organization from the perspective of customers, based on the method of aggregating linguistic information on a multilevel hierarchical system of quality assessment. The algorithm is of a constructive nature, it provides not only the possibility of obtaining an integral evaluation, but also the development of a quality improvement strategy based on the method of linguistic decomposition, which forms the minimum set of areas of work with clients whose quality change will allow obtaining the required level of integrated quality assessment.
Ayano, Getinet
2018-03-29
Mental health legislation (MHL) is required to ensure a regulatory framework for mental health services and other providers of treatment and care, and to ensure that the public and people with a mental illness are afforded protection from the often-devastating consequences of mental illness. To provide an overview of evidence on the significance of MHL for successful primary care for mental health and community mental health servicesMethod: A qualitative review of the literature on the significance of MHL for successful primary care for mental health and community mental health services was conducted. In many countries, especially in those who have no MHL, people do not have access to basic mental health care and treatment they require. One of the major aims of MHL is that all people with mental disorders should be provided with treatment based on the integration of mental health care services into the primary healthcare (PHC). In addition, MHL plays a crucial role in community integration of persons with mental disorders, the provision of care of high quality, the improvement of access to care at community level. Community-based mental health care further improves access to mental healthcare within the city, to have better health and mental health outcomes, and better quality of life, increase acceptability, reduce associated social stigma and human rights abuse, prevent chronicity and physical health comorbidity will likely to be detected early and managed. Mental health legislation plays a crucial role in community integration of persons with mental disorders, integration of mental health at primary health care, the provision of care of high quality and the improvement of access to care at community level. It is vital and essential to have MHL for every country.
Ozone Satellite Data Synergy and Combination with Non-satellite Data in the AURORA project
NASA Astrophysics Data System (ADS)
Cortesi, U.; Tirelli, C.; Arola, A.; Dragani, R.; Keppens, A.; Loenen, E.; Masini, A.; Tsiakos, , C.; van der A, R.; Verberne, K.
2017-12-01
The geostationary satellite constellation composed of TEMPO (North America), SENTINEL-4 (Europe) and GEMS (Asia) missions is a major instance of space component in the fundamentally new paradigm aimed at integrating information on air quality from a wide variety of sources. Space-borne data on tropospheric composition from new generation satellites have a growing impact in this context because of their unprecedented quantity and quality, while merging with non-satellite measurements and other types of auxiliary data via state-of-the-art modelling capabilities remains essential to fit the purpose of highly accurate information made readily available at high temporal and spatial resolution, both in analysis and forecast mode. Proper and effective implementation of this paradigm poses severe challenges to science, technology and applications that must be addressed in a closely interconnected manner to pave the way to high quality products and innovative services. Novel ideas and tools built on these three pillars are currently under investigation in the AURORA (Advanced Ultraviolet Radiation and Ozone Retrieval for Applications) Horizon 2020 project of the European Commission. The primary goal of the project is the proof of concept of a synergistic approach to the exploitation of Sentinel-4 and -5 Ozone measurements in the UV, Visible and Thermal Infrared based on the combination of an innovative data fusion method and assimilation models. The scientific objective shares the same level of priority with the technological effort to realize a prototype data processor capable to manage the full data processing chain and with the development of two downstream applications for demonstration purposes. The presentation offers a first insight in mid-term results of the project, which is mostly based on the use of synthetic data from the atmospheric Sentinels. Specific focus is given to the role of satellite data synergy in integrated systems for air quality monitoring, in particular when testing the impact of TEMPO and GEMS Ozone data in AURORA. As a further element relevant for the integration of multiple data sources, we describe the AIR-Portal application, which is going to combine AURORA partial columns of tropospheric ozone with other source of information for air quality analysis and forecast in metropolitan areas.
Huang, Kai; Jia, Qi; You, Tiangui; Zhang, Runchun; Lin, Jiajie; Zhang, Shibin; Zhou, Min; Zhang, Bo; Yu, Wenjie; Ou, Xin; Wang, Xi
2017-11-08
Die-to-wafer heterogeneous integration of single-crystalline GaN film with CMOS compatible Si(100) substrate using the ion-cutting technique has been demonstrated. The thermodynamics of GaN surface blistering is in-situ investigated via a thermal-stage optical microscopy, which indicates that the large activation energy (2.5 eV) and low H ions utilization ratio (~6%) might result in the extremely high H fluence required for the ion-slicing of GaN. The crystalline quality, surface topography and the microstructure of the GaN films are characterized in detail. The full width at half maximum (FWHM) for GaN (002) X-ray rocking curves is as low as 163 arcsec, corresponding to a density of threading dislocation of 5 × 10 7 cm -2 . Different evolution of the implantation-induced damage was observed and a relationship between the damage evolution and implantation-induced damage is demonstrated. This work would be beneficial to understand the mechanism of ion-slicing of GaN and to provide a platform for the hybrid integration of GaN devices with standard Si CMOS process.
RF performances of inductors integrated on localized p+-type porous silicon regions
2012-01-01
To study the influence of localized porous silicon regions on radiofrequency performances of passive devices, inductors were integrated on localized porous silicon regions, full porous silicon sheet, bulk silicon and glass substrates. In this work, a novel strong, resistant fluoropolymer mask is introduced to localize the porous silicon on the silicon wafer. Then, the quality factors and resonant frequencies obtained with the different substrates are presented. A first comparison is done between the performances of inductors integrated on same-thickness localized and full porous silicon sheet layers. The effect of the silicon regions in the decrease of performances of localized porous silicon is discussed. Then, the study shows that the localized porous silicon substrate significantly reduces losses in comparison with high-resistivity silicon or highly doped silicon bulks. These results are promising for the integration of both passive and active devices on the same silicon/porous silicon hybrid substrate. PMID:23009746
Towards an integrated quality control procedure for eddy-covariance data
NASA Astrophysics Data System (ADS)
Vitale, Domenico; Papale, Dario
2017-04-01
The eddy-covariance technique is nowadays the most reliable and direct way, allowing to calculate the main fluxes of Sensible and Latent Heat and of Net Ecosystem Exchange, this last being the result of the difference between the CO2 assimilated by photosynthetic activities and those released to the atmosphere through the ecosystem respiration processes. Despite the improvements in accuracy of measurement instruments and software development, the eddy-covariance technique is not suitable under non-ideal conditions respect to the instruments characteristics and the physical assumption behind the technique mainly related to the well-developed and stationary turbulence conditions. Under these conditions the calculated fluxes are not reliable and need to be flagged and discarded. In order to discover these unavoidable "bad" fluxes and build dataset with the highest quality, several tests applied both on high-frequency (10-20 Hz) raw data and on half-hourly times series have been developed in the past years. Nevertheless, there is an increasing need to develop a standardized quality control procedure suitable not only for the analysis of long-term data, but also for the near-real time data processing. In this paper, we review established quality assessment procedures and present an innovative quality control strategy with the purpose of integrating the existing consolidated procedures with robust and advanced statistical tests more suitable for the analysis of time series data. The performance of the proposed quality control strategy is evaluated both on simulated and EC data distributed by the ICOS research infrastructure. It is concluded that the proposed strategy is able to flag and exclude unrealistic fluxes while being reproducible and retaining the largest possible amount of high quality data.
A review of integrated heart failure care.
MacInnes, Julie; Williams, Liz
2018-06-18
AimThe aim of this integrative review is to determine the effectiveness of integrated heart failure (HF) care in terms of patient-, service- and resource-related outcomes, and to determine what model or characteristics of integrated care work best, for whom and in what contexts. Integration of health and social care services is a significant driver in the development of better and more cost-effective health and social care systems in Europe and developed countries. As high users of health and social care services, considerable attention has been paid to the care of people with long-term conditions. HF is a progressive, prevalent and disabling condition, requiring complex management involving multiple health and social care agencies. An integrative review was conducted according to a framework by Whittemore and Knafl (2005). A literature search was undertaken using the databases: Medline, CINAHL, Embase, PsychINFO and the Cochrane Library, using key words of 'heart failure' OR 'cardiac failure' AND 'integrated' OR 'multidisciplinary' OR 'interdisciplinary' OR 'multiprofessional' OR 'interprofessional' OR 'collaborative care'. Application of the inclusion and exclusion criteria resulted in 17 articles being included in the review. Articles were screened and coded for methodological quality according to a two-point criteria. Data were extracted using a template and analysed thematically.FindingsIntegrated HF care results in enhanced quality of life (QoL), and improved symptom control and self-management. Reduced admission rates, reduced length of hospital stay, improved prescribing practices and better care co-ordination are also reported. There is more limited evidence for improved efficiency although overall costs may be reduced. Although findings are highly context dependent, key features of integrated HF models are: liaison between primary and secondary care services to facilitate planned discharge, early and medium term follow-up, multidisciplinary patient education and team working including shared professional education, and the development and implementation of comprehensive care pathways.
Isolation of high-quality total RNA from leaves of Myrciaria dubia "CAMU CAMU".
Gómez, Juan Carlos Castro; Reátegui, Alina Del Carmen Egoavil; Flores, Julián Torres; Saavedra, Roberson Ramírez; Ruiz, Marianela Cobos; Correa, Sixto Alfredo Imán
2013-01-01
Myrciaria dubia is a main source of vitamin C for people in the Amazon region. Molecular studies of M. dubia require high-quality total RNA from different tissues. So far, no protocols have been reported for total RNA isolation from leaves of this species. The objective of this research was to develop protocols for extracting high-quality total RNA from leaves of M. dubia. Total RNA was purified following two modified protocols developed for leaves of other species (by Zeng and Yang, and by Reid et al.) and one modified protocol developed for fruits of the studied species (by Silva). Quantity and quality of purified total RNA were assessed by spectrophotometric and electrophoretic analysis. Additionally, quality of total RNA was evaluated with reverse-transcription polymerase chain reaction (RT-PCR). With these three modified protocols we were able to isolate high-quality RNA (A260nm/A280nm >1.9 and A260nm/A230nm >2.0). Highest yield was produced with the Zeng and Yang modified protocol (384±46µg ARN/g fresh weight). Furthermore, electrophoretic analysis showed the integrity of isolated RNA and the absence of DNA. Another proof of the high quality of our purified RNA was the successful cDNA synthesis and amplification of a segment of the M. dubia actin 1 gene. We report three modified protocols for isolation total RNA from leaves of M. dubia. The modified protocols are easy, rapid, low in cost, and effective for high-quality and quantity total RNA isolation suitable for cDNA synthesis and polymerase chain reaction.
An improved multi-exposure approach for high quality holographic femtosecond laser patterning
NASA Astrophysics Data System (ADS)
Zhang, Chenchu; Hu, Yanlei; Li, Jiawen; Lao, Zhaoxin; Ni, Jincheng; Chu, Jiaru; Huang, Wenhao; Wu, Dong
2014-12-01
High efficiency two photon polymerization through single exposure via spatial light modulator (SLM) has been used to decrease the fabrication time and rapidly realize various micro/nanostructures, but the surface quality remains a big problem due to the speckle noise of optical intensity distribution at the defocused plane. Here, a multi-exposure approach which used tens of computer generate holograms successively loaded on SLM is presented to significantly improve the optical uniformity without losing efficiency. By applying multi-exposure, we found that the uniformity at the defocused plane was increased from ˜0.02 to ˜0.6 according to our simulation. The fabricated two series of letters "HELLO" and "USTC" under single-and multi-exposure in our experiment also verified that the surface quality was greatly improved. Moreover, by this method, several kinds of beam splitters with high quality, e.g., 2 × 2, 5 × 5 Daman, and complex nonseperate 5 × 5, gratings were fabricated with both of high quality and short time (<1 min, 95% time-saving). This multi-exposure SLM-two-photon polymerization method showed the promising prospect in rapidly fabricating and integrating various binary optical devices and their systems.
Fabrication of high-quality single-crystal Cu thin films using radio-frequency sputtering.
Lee, Seunghun; Kim, Ji Young; Lee, Tae-Woo; Kim, Won-Kyung; Kim, Bum-Su; Park, Ji Hun; Bae, Jong-Seong; Cho, Yong Chan; Kim, Jungdae; Oh, Min-Wook; Hwang, Cheol Seong; Jeong, Se-Young
2014-08-29
Copper (Cu) thin films have been widely used as electrodes and interconnection wires in integrated electronic circuits, and more recently as substrates for the synthesis of graphene. However, the ultra-high vacuum processes required for high-quality Cu film fabrication, such as molecular beam epitaxy (MBE), restricts mass production with low cost. In this work, we demonstrated high-quality Cu thin films using a single-crystal Cu target and radio-frequency (RF) sputtering technique; the resulting film quality was comparable to that produced using MBE, even under unfavorable conditions for pure Cu film growth. The Cu thin film was epitaxially grown on an Al2O3 (sapphire) (0001) substrate, and had high crystalline orientation along the (111) direction. Despite the 10(-3) Pa vacuum conditions, the resulting thin film was oxygen free due to the high chemical stability of the sputtered specimen from a single-crystal target; moreover, the deposited film had >5× higher adhesion force than that produced using a polycrystalline target. This fabrication method enabled Cu films to be obtained using a simple, manufacturing-friendly process on a large-area substrate, making our findings relevant for industrial applications.
Reexamining "Brown" Twenty-Five Years Later: Looking Backward into the Future.
ERIC Educational Resources Information Center
Carter, Robert L.
1979-01-01
While not abandoning the goal of integration in the schools, poor blacks should aim toward obtaining a high quality education, obtaining equal education whatever the setting. Available from William S. Hein & Co., Inc., 1285 Main St., Buffalo, NY 14209. (IRT)
Highly localized distributed Brillouin scattering response in a photonic integrated circuit
NASA Astrophysics Data System (ADS)
Zarifi, Atiyeh; Stiller, Birgit; Merklein, Moritz; Li, Neuton; Vu, Khu; Choi, Duk-Yong; Ma, Pan; Madden, Stephen J.; Eggleton, Benjamin J.
2018-03-01
The interaction of optical and acoustic waves via stimulated Brillouin scattering (SBS) has recently reached on-chip platforms, which has opened new fields of applications ranging from integrated microwave photonics and on-chip narrow-linewidth lasers, to phonon-based optical delay and signal processing schemes. Since SBS is an effect that scales exponentially with interaction length, on-chip implementation on a short length scale is challenging, requiring carefully designed waveguides with optimized opto-acoustic overlap. In this work, we use the principle of Brillouin optical correlation domain analysis to locally measure the SBS spectrum with high spatial resolution of 800 μm and perform a distributed measurement of the Brillouin spectrum along a spiral waveguide in a photonic integrated circuit. This approach gives access to local opto-acoustic properties of the waveguides, including the Brillouin frequency shift and linewidth, essential information for the further development of high quality photonic-phononic waveguides for SBS applications.
NASA Astrophysics Data System (ADS)
De Dreuzy, J. R.; Marçais, J.; Moatar, F.; Minaudo, C.; Courtois, Q.; Thomas, Z.; Longuevergne, L.; Pinay, G.
2017-12-01
Integration of hydrological and biogeochemical processes led to emerging patterns at the catchment scale. Monitoring in rivers reflects the aggregation of these effects. While discharge time series have been measured for decades, high frequency water quality monitoring in rivers now provides prominent measurements to characterize the interplay between hydrological and biogeochemical processes, especially to infer the processes that happen in the heterogeneous subsurface. However, we still lack frameworks to relate observed patterns to specific processes, because of the "organized complexity" of hydrological systems. Indeed, it is unclear what controls, for example, patterns in concentration-discharge (C/Q) relationships due to non-linear processes and hysteresis effects. Here we develop a non-intensive process-based model to test how the integration of different landforms (i.e. geological heterogeneities and structures, topographical features) with different biogeochemical reactivity assumptions (e.g. reactive zone locations) can shape the overall water quality time series. With numerical experiments, we investigate typical patterns in high frequency C/Q relationships. In headwater basins, we found that typical hysteretic patterns in C/Q relationships observed in data time series can be attributed to differences in water and solute locations stored across the hillslope. At the catchment scale though, these effects tend to average out by integrating contrasted hillslopes' landforms. Together these results suggest that information contained in headwater water quality monitoring can be used to understand how hydrochemical processes determine downstream conditions.
Qubit Coupled Mechanical Resonator in an Electromechanical System
NASA Astrophysics Data System (ADS)
Hao, Yu
This thesis describes the development of a hybrid quantum electromechanical system. In this system the mechanical resonator is capacitively coupled to a superconducting transmon which is embedded in a superconducting coplanar waveguide (CPW) cavity. The difficulty of achieving high quality of superconducting qubit in a high-quality voltage-biased cavity is overcome by integrating a superconducting reflective T-filter to the cavity. Further spectroscopic and pulsed measurements of the hybrid system demonstrate interactions between the ultra-high frequency mechanical resonator and transmon qubit. The noise of mechanical resonator close to ground state is measured by looking at the spectroscopy of the transmon. At last, fabrication and tests of membrane resonators are discussed.
Flexible and stretchable electronics for biointegrated devices.
Kim, Dae-Hyeong; Ghaffari, Roozbeh; Lu, Nanshu; Rogers, John A
2012-01-01
Advances in materials, mechanics, and manufacturing now allow construction of high-quality electronics and optoelectronics in forms that can readily integrate with the soft, curvilinear, and time-dynamic surfaces of the human body. The resulting capabilities create new opportunities for studying disease states, improving surgical procedures, monitoring health/wellness, establishing human-machine interfaces, and performing other functions. This review summarizes these technologies and illustrates their use in forms integrated with the brain, the heart, and the skin.
2006-10-16
spawning sites, feeding sites, 20 seasonal wetlands or drylands, water quality or quantity, host species or plant pollinators , geological 21...rufus]). 12 These areas also contain relatively large areas of sensitive plants . 13 3.9.2.9 Significant Ecological Areas found within the R-2515 and...for complete aircraft, avionics systems, and integrated 21 airframe weapons support. Thus, HPM testing would continue the evolution of the primary
NASA Astrophysics Data System (ADS)
Glaser, Ulf; Li, Zhichao; Bichmann, Stephan, II; Pfeifer, Tilo
2003-05-01
By China's entry into the WTO, Chinese as well as German companies are facing the question, how to minimize the risk of unfamiliar cooperation partners when developing products. The rise of customer demands concerning quality, product diversity and the reduction of expenses require flexibility and efficiency with reliable component suppliers. In order to build and strengthen sino-german cooperations, a manufacturing control using homogenized and efficient measures to assure high quality is of vital importance. Lack of unifications may cause identical measurements conducted at subcontractors or customers to be carried out with different measurement processes which leads to incomparable results. Rapidly growing company cooperations and simultaneously decreasing of manufacturing scope cause substantial difficulties when coordinating joint quality control activities. "ProSens," a sino-german project consortium consisting of industrial users, technology producers and research institutes, aims at improving selected production processes by: Creation of a homogeneous quality awareness in sino-german cooperations. Sensitization for process accompanying metrology at an early stage of product development. Increase of the process performance by the use of integrated metrology. Reduction of production time and cost. Unification of quality control of complex products by means of efficient measurement strategies and CAD-based inspection planning.
Delaminated Transfer of CVD Graphene
NASA Astrophysics Data System (ADS)
Clavijo, Alexis; Mao, Jinhai; Tilak, Nikhil; Altvater, Michael; Andrei, Eva
Single layer graphene is commonly synthesized by dissociation of a carbonaceous gas at high temperatures in the presence of a metallic catalyst in a process known as Chemical Vapor Deposition or CVD. Although it is possible to achieve high quality graphene by CVD, the standard transfer technique of etching away the metallic catalyst is wasteful and jeopardizes the quality of the graphene film by contamination from etchants. Thus, development of a clean transfer technique and preservation of the parent substrate remain prominent hurdles to overcome. In this study, we employ a copper pretreatment technique and optimized parameters for growth of high quality single layer graphene at atmospheric pressure. We address the transfer challenge by utilizing the adhesive properties between a polymer film and graphene to achieve etchant-free transfer of graphene films from a copper substrate. Based on this concept we developed a technique for dry delamination and transferring of graphene to hexagonal boron nitride substrates, which produced high quality graphene films while at the same time preserving the integrity of the copper catalyst for reuse. DOE-FG02-99ER45742, Ronald E. McNair Postbaccalaureate Achievement Program.
NASA Astrophysics Data System (ADS)
Chang, N. B.
2016-12-01
Many countries concern about development and redevelopment efforts in urban regions to reduce the flood risk by considering hazards such as high-tide events, storm surge, flash floods, stormwater runoff, and impacts of sea level rise. Combining these present and future hazards with vulnerable characteristics found throughout coastal communities such as majority low-lying areas and increasing urban development, create scenarios for increasing exposure of flood hazard. As such, the most vulnerable areas require adaptation strategies and mitigation actions for flood hazard management. In addition, in the U.S., Numeric Nutrient Criteria (NNC) are a critical tool for protecting and restoring the designated uses of a waterbody with regard to nitrogen and phosphorus pollution. Strategies such as low impact development (LID) have been promoted in recent years as an alternative to traditional stormwater management and drainage to control both flooding and water quality impact. LID utilizes decentralized multifunctional site designs and incorporates on-site storm water management practices rather than conventional storm water management approaches that divert flow toward centralized facilities. How to integrate hydrologic and water quality models to achieve the decision support becomes a challenge. The Cross Bayou Watershed of Pinellas County in Tampa Bay, a highly urbanized coastal watershed, is utilized as a case study due to its sensitivity to flood hazards and water quality management within the watershed. This study will aid the County, as a decision maker, to implement its stormwater management policy and honor recent NNC state policy via demonstration of an integrated hydrologic and water quality model, including the Interconnected Channel and Pond Routing Model v.4 (ICPR4) and the BMPTRAIN model as a decision support tool. The ICPR4 can be further coupled with the ADCIRC/SWAN model to reflect the storm surge and seal level rise in coastal regions.
Total Quality Management Office for Contracting Integrity Implementation Plan
1989-07-01
REPORT______ANDDATESCOVERED 4. TITLE AND SUBTITLE S. FUNDING NUMBERS Total Quality Management Office for Contracting Integrity Implementatiun Plan 6. AUTHOR(S) 7...01-280-5500 Standard Form 298 (Rev. 2-89) P’,croed 1:, ANSI Std 3J9-16 29d. 102 4 TOTAL QUALITY MANAGEMENT OFFICE FOR CONTRACTING INTEGRITY...IMPLEMENTATION PLAN According to the Total Quality Management (TQM) Master Plan, each PSE head, supported by Working Groups, will implement the HQ DLA Master
Coupling Ideality of Integrated Planar High-Q Microresonators
NASA Astrophysics Data System (ADS)
Pfeiffer, Martin H. P.; Liu, Junqiu; Geiselmann, Michael; Kippenberg, Tobias J.
2017-02-01
Chip-scale optical microresonators with integrated planar optical waveguides are useful building blocks for linear, nonlinear, and quantum-optical photonic devices alike. Loss reduction through improving fabrication processes results in several integrated microresonator platforms attaining quality (Q ) factors of several millions. Beyond the improvement of the quality factor, the ability to operate the microresonator with high coupling ideality in the overcoupled regime is of central importance. In this regime, the dominant source of loss constitutes the coupling to a single desired output channel, which is particularly important not only for quantum-optical applications such as the generation of squeezed light and correlated photon pairs but also for linear and nonlinear photonics. However, to date, the coupling ideality in integrated photonic microresonators is not well understood, in particular, design-dependent losses and their impact on the regime of high ideality. Here we investigate design-dependent parasitic losses described by the coupling ideality of the commonly employed microresonator design consisting of a microring-resonator waveguide side coupled to a straight bus waveguide, a system which is not properly described by the conventional input-output theory of open systems due to the presence of higher-order modes. By systematic characterization of multimode high-Q silicon nitride microresonator devices, we show that this design can suffer from low coupling ideality. By performing 3D simulations, we identify the coupling to higher-order bus waveguide modes as the dominant origin of parasitic losses which lead to the low coupling ideality. Using suitably designed bus waveguides, parasitic losses are mitigated with a nearly unity ideality and strong overcoupling (i.e., a ratio of external coupling to internal resonator loss rate >9 ) are demonstrated. Moreover, we find that different resonator modes can exchange power through the coupler, which, therefore, constitutes a mechanism that induces modal coupling, a phenomenon known to distort resonator dispersion properties. Our results demonstrate the potential for significant performance improvements of integrated planar microresonators for applications in quantum optics and nonlinear photonics achievable by optimized coupler designs.
ERIC Educational Resources Information Center
Kadyrova, Alina A.; Valeev, Agzam A.
2016-01-01
There is a determined number of trends in the process of intensification of high school training, including the integration of professional, linguistic and cultural training of professionals in the unity with the development of their personal qualities;. For this reason, modern educational technologies serve as a tool for practical implementation…
Gonzalez, M E; Jernstedt, J A; Slaughter, D C; Barrett, D M
2010-09-01
The integrity of onion cells and its impact on tissue texture after high pressure and thermal processing was studied. The contribution of cell membranes and the pectic component of cell walls on the texture properties of onion tissue were analyzed. Neutral red (NR) staining of onion parenchyma cell vacuoles was used for the evaluation of cell membrane integrity and microscopic image analysis was used for its quantification. The content of methanol in tissue as a result of pectin methylesterase activity was used to evaluate the pectin component of the middle lamella and cell walls and the hardening effect on the tissue after processing. High pressure treatments consisted of 5-min holding times at 50, 100, 200, 300, or 600 MPa. Thermal treatments consisted of 30-min water bath exposure to 40, 50, 60, 70, or 90 °C. In the high pressure treatments, loss of membrane integrity commenced at 200 MPa and total loss of membrane integrity occurred at 300 MPa and above. In the thermal treatments, membrane integrity was lost between 50 and 60 °C. The texture of onions was influenced by the state of the membranes and texture profiles were abruptly modified once membrane integrity was lost. Hardening of the tissue corresponded with pressure and temperature PME activation and occurred after membrane integrity loss. The texture of vegetables is an important quality attribute that affects consumer preference. Loss of textural integrity also indicates that other biochemical reactions that affect color, flavor, and nutrient content may occur more rapidly. In this study, we analyzed changes in the texture of onions after preservation with heat and high pressure.
High-quality quantum-dot-based full-color display technology by pulsed spray method
NASA Astrophysics Data System (ADS)
Chen, Kuo-Ju; Chen, Hsin-Chu; Tsai, Kai-An; Lin, Chien-Chung; Tsai, Hsin-Han; Chien, Shih-Hsuan; Cheng, Bo-Siao; Hsu, Yung-Jung; Shih, Min-Hsiung; Kuo, Hao-Chung
2013-03-01
We fabricated the colloidal quantum-dot light-emitting diodes (QDLEDs) with the HfO2/SiO2-distributed Bragg reflector (DBR) structure using a pulsed spray coating method. Moreover, pixelated RGB arrays, 2-in. wafer-scale white light emission, and an integrated small footprint white light device were demonstrated. The experimental results showed that the intensity of red, blue, and green (RGB) emissions exhibited considerable enhancement because of the high reflectivity in the UV region by the DBR structure, which subsequently increased the use in the UV optical pumping of RGB QDs. In this experiment, a pulsed spray coating method was crucial in providing uniform RGB layers, and the polydimethylsiloxane (PDMS) film was used as the interface layer between each RGB color to avoid crosscontamination and self-assembly of QDs. Furthermore, the chromaticity coordinates of QDLEDs with the DBR structure remained constant under various pumping powers in the large area sample, whereas a larger shift toward high color temperatures was observed in the integrated device. The resulting color gamut of the proposed QDLEDs covered an area 1.2 times larger than that of the NTSC standard, which is favorable for the next generation of high-quality display technology.
An integrated low phase noise radiation-pressure-driven optomechanical oscillator chipset
Luan, Xingsheng; Huang, Yongjun; Li, Ying; McMillan, James F.; Zheng, Jiangjun; Huang, Shu-Wei; Hsieh, Pin-Chun; Gu, Tingyi; Wang, Di; Hati, Archita; Howe, David A.; Wen, Guangjun; Yu, Mingbin; Lo, Guoqiang; Kwong, Dim-Lee; Wong, Chee Wei
2014-01-01
High-quality frequency references are the cornerstones in position, navigation and timing applications of both scientific and commercial domains. Optomechanical oscillators, with direct coupling to continuous-wave light and non-material-limited f × Q product, are long regarded as a potential platform for frequency reference in radio-frequency-photonic architectures. However, one major challenge is the compatibility with standard CMOS fabrication processes while maintaining optomechanical high quality performance. Here we demonstrate the monolithic integration of photonic crystal optomechanical oscillators and on-chip high speed Ge detectors based on the silicon CMOS platform. With the generation of both high harmonics (up to 59th order) and subharmonics (down to 1/4), our chipset provides multiple frequency tones for applications in both frequency multipliers and dividers. The phase noise is measured down to −125 dBc/Hz at 10 kHz offset at ~400 μW dropped-in powers, one of the lowest noise optomechanical oscillators to date and in room-temperature and atmospheric non-vacuum operating conditions. These characteristics enable optomechanical oscillators as a frequency reference platform for radio-frequency-photonic information processing. PMID:25354711
Hack, Carolin C; Antoniadis, Sophia; Hackl, Janina; Langemann, Hanna; Schwitulla, Judith; Fasching, Peter A; Beckmann, Matthias W; Theuser, Anna-Katharin
2018-07-01
Complementary medicine services are nowadays usually quite heterogeneous, and little information is available on standards for running an integrative medicine consultancy service. This study aimed to assess patients' satisfaction with a standardized treatment service on integrative medicine. Using a cross-sectional design, 75 breast cancer patients from the integrative medicine consultancy service at the University Breast Center for Franconia were evaluated between January 2016 and March 2017. At primary consultation, patients answered a standardized questionnaire on their medical history and treatment goals regarding integrative medicine. In a subsequent interview, patients evaluated their satisfaction with the treatment service and individual treatment goals. 72% of the patients (n = 54) reported high satisfaction with the overall approach of the treatment service. 76% of the patients (n = 57) were very satisfied or satisfied with their individual treatment plans. The most frequently reported goals were to slow tumor progression (n = 64, 85.3%), reducing the side effects of conventional cancer treatments (n = 60, 80%), and a desire to participate actively in the treatment of breast cancer (n = 64, 85.3%). Using a standardized procedure in integrative medicine allows a high quality level to be offered to patients. Overall, breast cancer patients report very high satisfaction with the integrative medicine consultancy service and state long-term treatment goals. Hence, long-term treatment with integrative medicine methods should be taken into consideration.
Masters, Kelli
2016-03-01
The Institute of Medicine and American Association of Colleges of Nursing are calling for curriculum redesign that prepares nursing students with the requisite knowledge and skills to provide safe, high quality care. The purpose of this project was to improve nursing students' knowledge of quality and safety by integrating Quality and Safety Education for Nurses into clinical nursing education through development of a dedicated education unit. This model, which pairs nursing students with front-line nursing staff for clinical experiences, was implemented on a medical floor in an acute care hospital. Prior to implementation, nurses and students were educated about the dedicated education unit and quality and safety competencies. During each clinical rotation, students collaborated with their nurses on projects related to these competencies. Students' knowledge was assessed using questions related to quality and safety. Students who participated in the dedicated education unit had higher scores than those with traditional clinical rotations. Focus groups were held mid-semester to assess nurses' perceptions of the experience. Five themes emerged from the qualitative data including thirsting for knowledge, building teamwork and collaboration, establishing trust and decreasing anxiety, mirroring organization and time management skills, and evolving confidence in the nursing role. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sens, Brigitte
2010-01-01
The concept of general process orientation as an instrument of organisation development is the core principle of quality management philosophy, i.e. the learning organisation. Accordingly, prestigious quality awards and certification systems focus on process configuration and continual improvement. In German health care organisations, particularly in hospitals, this general process orientation has not been widely implemented yet - despite enormous change dynamics and the requirements of both quality and economic efficiency of health care processes. But based on a consistent process architecture that considers key processes as well as management and support processes, the strategy of excellent health service provision including quality, safety and transparency can be realised in daily operative work. The core elements of quality (e.g., evidence-based medicine), patient safety and risk management, environmental management, health and safety at work can be embedded in daily health care processes as an integrated management system (the "all in one system" principle). Sustainable advantages and benefits for patients, staff, and the organisation will result: stable, high-quality, efficient, and indicator-based health care processes. Hospitals with their broad variety of complex health care procedures should now exploit the full potential of total process orientation. Copyright © 2010. Published by Elsevier GmbH.
Vapor deposition and characterization of supramolecular assemblies for integrated nonlinear optics
NASA Astrophysics Data System (ADS)
Esembeson, Bweh
Very recently, some organic molecules have been developed that are very compact and have exceptionally high molecular polarizabilities which approach the fundamental quantum limit. Supramolecular assemblies created from such highly nonlinear molecules could find applications in integrated nonlinear optics such as all-optical signal processing, electro-optic modulators and frequency conversion. In this work, we have constructed a versatile vacuum deposition system for the creation of organic thin films from these molecules that can be sublimated without decomposition. We have used deposition temperatures of the order of 100--200°C in a high vacuum of 10-6--10 -7 Torrs. While some molecules showed a tendency to form polycrystalline films, others led to very high optical quality films, with a roughness of less than 10 nm over tens of micrometers and no grains detected down to a size of 2 nm, as seen in Atomic Force and Scanning Electron Microscopy studies. The best material we developed has a linear refractive index of 1.8 +/- 0.1 at 1.5 mum and an off-resonant third order susceptibility, chi (3), measured through Degenerate Four Wave Mixing, of 2 +/- 1 x 10-19 m2V-2 at 1.5 mum, a value three orders of magnitude larger than fused silica. This vapor deposited thin film may represent one of the best materials demonstrated to date whereby a large third order susceptibility, high optical quality, and simplicity of fabrication and integration are in perfect harmony for integrated nonlinear optical applications. We have used this novel organic material to create a hybrid organic/silicon-on-insulator waveguide that showed a record high nonlinearity coefficient of 10 5 W-1m-1 and has been used as an all-optical switch for demultiplexing a 120 Gbit/s data stream to 10 Gbit/s on a 6 mm long device.
Indoor air quality of everyday use spaces dedicated to specific purposes-a review.
Marć, Mariusz; Śmiełowska, Monika; Namieśnik, Jacek; Zabiegała, Bożena
2018-01-01
According to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements, and individual garages. Some aspects of air quality in large-scale car parks, as a specific type of indoor environment, are also discussed. All those areas are characterized by relatively short time use. On the other hand, high and very high concentration levels of xenobiotics can be observed, resulting in higher exposure risk. The main compounds or group of chemical compounds are presented and discussed. The main factors influencing the type and amount of chemical pollutants present in the air of such areas are indicated.
Hudak, R P; Jacoby, I; Meyer, G S; Potter, A L; Hooper, T I; Krakauer, H
1997-01-01
This article describes a training model that focuses on health care management by applying epidemiologic methods to assess and improve the quality of clinical practice. The model's uniqueness is its focus on integrating clinical evidence-based decision making with fundamental principles of resource management to achieve attainable, cost-effective, high-quality health outcomes. The target students are current and prospective clinical and administrative executives who must optimize decision making at the clinical and managerial levels of health care organizations.
Ohta, Tazro; Nakazato, Takeru; Bono, Hidemasa
2017-06-01
It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. © The Authors 2017. Published by Oxford University Press.
Nerkar, Sandeep S; Tamhankar, Ashok J; Khedkar, Smita U; Lundborg, Cecilia Stålsby
2014-06-01
In many hilly tribal areas of the world, water scarcity is a major problem and diarrhoea is common. Poor quality of water also affects the environment. An integrated watershed management programme (IWMP) aims to increase availability of water and to improve life conditions. Globally, there is a lack of information on water contamination, occurrence of diarrhoea and antibiotic resistance, a serious global concern, in relation to IWMP in hilly tribal areas. Therefore, a prospective observational study was conducted during 2011–2012 in six villages in a hilly tribal belt of India, three with and three without implementation of an IWMP, to explore quality of water, diarrhoeal cases in the community and antibiotic resistance of Escherichia coli from water sources. The results showed that physico-chemical quality of water was within limits of safe consumption in all samples. The odds of coliform contamination in water samples was 2.3 times higher in non-watershed management villages (NWMV) compared to integrated watershed management villages (IWMV) (95% CI 0.8–6.45, p = 0.081). The number of diarrhoeal cases (18/663 vs. 42/639, p < 0.05) was lower in IWMV as compared to NWMV. Overall E. coli isolates showed high susceptibility to antibiotics. Resistance to a wider range of antibiotics was observed in NWMV.
Nerkar, Sandeep S.; Tamhankar, Ashok J.; Khedkar, Smita U.; Stålsby Lundborg, Cecilia
2014-01-01
In many hilly tribal areas of the world, water scarcity is a major problem and diarrhoea is common. Poor quality of water also affects the environment. An integrated watershed management programme (IWMP) aims to increase availability of water and to improve life conditions. Globally, there is a lack of information on water contamination, occurrence of diarrhoea and antibiotic resistance, a serious global concern, in relation to IWMP in hilly tribal areas. Therefore, a prospective observational study was conducted during 2011–2012 in six villages in a hilly tribal belt of India, three with and three without implementation of an IWMP, to explore quality of water, diarrhoeal cases in the community and antibiotic resistance of Escherichia coli from water sources. The results showed that physico-chemical quality of water was within limits of safe consumption in all samples. The odds of coliform contamination in water samples was 2.3 times higher in non-watershed management villages (NWMV) compared to integrated watershed management villages (IWMV) (95% CI 0.8–6.45, p = 0.081). The number of diarrhoeal cases (18/663 vs. 42/639, p < 0.05) was lower in IWMV as compared to NWMV. Overall E. coli isolates showed high susceptibility to antibiotics. Resistance to a wider range of antibiotics was observed in NWMV. PMID:24991664
USDA-ARS?s Scientific Manuscript database
Lignin depolymerization to aromatic monomers with high yields and selectivity is essential for the economic feasibility of many lignin-valorization strategies within integrated biorefining processes. Importantly, the quality and properties of the lignin source play an essential role in impacting the...
Improving the roadside environment through integrating air quality and traffic-related data.
DOT National Transportation Integrated Search
2016-12-01
Urban arterial corridors are landscapes that give rise to short and long-term : exposures to transportation-related pollution. With high traffic volumes, congestion, and : a wide mix of road users and land uses at the road edge, urban arterial enviro...
78 FR 35038 - Proposed Information Collection Activity; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-11
..., reliable, and transparent method for identifying high-quality programs that can receive continuing five... the system is working. The study will employ a mixed-methods design that integrates and layers administrative and secondary data sources, observational measures, and interviews to develop a rich knowledge...
Pedagogical Content of National Physical Behavior of Kazakh People
ERIC Educational Resources Information Center
Lesbekova, Ryskul; Nassiyev, Yermek; ?itpanbet, Amanshol; Nassiyev, Yeldar
2016-01-01
Physical education significantly contributes to students' well-being; therefore, it is an instructional priority for California schools and an integral part of our students' educational experience. High-quality physical education instruction contributes to good health, develops fundamental and advanced motor skills, improves students'…
Strong Collaborative Relationships for Strong Community Schools
ERIC Educational Resources Information Center
Daniel, Julia
2017-01-01
Community schools have gained attention as mechanisms to bring about equitable access to high-quality educational resources, extended learning time and opportunities, integrated student supports, and collaborative engaging relationships with parents and communities. In order to effectively create conditions that provide equitable access to such…
Wu, H Y; Chen, K L; Chen, Z H; Chen, Q H; Qiu, Y P; Wu, J C; Zhang, J F
2012-03-01
This research presented an evaluation for the ecological quality status (EcoQS) of three semi-enclosed coastal areas using fuzzy integrated assessment method (FIAM). With this method, the hierarchy structure was clarified by an index system of 11 indicators selected from biotic elements and physicochemical elements, and the weight vector of index system was calculated with Delphi-Analytic Hierarchy Process (AHP) procedure. Then, the FIAM was used to achieve an EcoQS assessment. As a result of assessment, most of the sampling stations demonstrated a clear gradient in EcoQS, ranging from high to poor status. Among the four statuses, high and good, owning a ratio of 55.9% and 26.5%, respectively, were two dominant statuses for three bays, especially for Sansha Bay and Luoyuan Bay. The assessment results were found consistent with the pressure information and parameters obtained at most stations. In addition, the sources of uncertainty in classification of EcoQS were also discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Rosado, Daniel; Usero, José; Morillo, José
2015-09-15
A new integrated sediment quality assessment method composed of several assays (particle size profile, total metal content, protease K extraction, total organic carbon, toxicity bioassay with Photobacterium phosphoreum and macrobenthic community alteration) that provides a single result, the environmental degradation index (EDI), has been developed. The new method was tested on the Huelva estuary (southwest of Spain), a highly polluted area where metals dissolved in the water of the Tinto and Odiel rivers precipitate after flowing through the Iberian Pyrite Belt, one of the largest metallogenic areas of massive sulphide deposits in the world. The proposed method satisfactorily was able to reflect different degrees of pollution on the environmental degradation index. Thus, EDI categorized littoral samples as slightly degraded and all the Tinto and some of the Odiel as very highly degraded, emphasizing the lower zone of the Tinto estuary as the most deeply degraded of the entire study area. Copyright © 2015 Elsevier Ltd. All rights reserved.
Integrated Geospatial Education and Technology Training for High School Age Youth (HiGETT)
NASA Astrophysics Data System (ADS)
Allen, J. E.
2012-12-01
The Landsat series of satellites provides high quality, consistent, 30 m resolution data for studies of landscape-scale change over time at no cost to the user. The availability of the Landsat data archive and the effectiveness and ease of its use to solve practical societal problems, particularly integrated with Geographic Information Systems (GIS), has been a key factor in a movement to bring remote sensing education to community colleges (as in the "iGETT" program funded by the National Science Foundation, 2007-2011) and now to younger students of high school age. "Integrated Geospatial Education and Technology Training for High School Age Youth (HiGETT)" was a two-day meeting convened April 4-5, 2011 to explore and articulate effective means of reaching teens with geospatial technology education and career awareness. Participants represented industry, government, academia, and informal education organizations such as 4-H and Girl Scouts. This poster will summarize a report on that meeting.
Wang, Xiaoxia; Shoaib, Muhammad; Wang, Xiao; Zhang, Xuehong; He, Mai; Luo, Ziyu; Zheng, Weihao; Li, Honglai; Yang, Tiefeng; Zhu, Xiaoli; Ma, Libo; Pan, Anlian
2018-06-14
Cesium lead halide perovskite nanowires have emerged as promising low-dimensional semiconductor structures for integrated photonic applications. Understanding light-matter interactions in a nanowire cavity is of both fundamental and practical interest in designing low-power-consumption nanoscale light sources. In this work, high-quality in-plane aligned halide perovskite CsPbX 3 (X = Cl, Br, I) nanowires are synthesized by a vapor growth method on an annealed M-plane sapphire substrate. Large-area nanowire laser arrays have been achieved based on the as-grown aligned CsPbX 3 nanowires at room temperature with quite low pumping thresholds, very high quality factors, and a high degree of linear polarization. More importantly, it is found that exciton-polaritons are formed in the nanowires under the excitation of a pulsed laser, indicating a strong exciton-photon coupling in the optical microcavities made of cesium lead halide perovskites. The coupling strength in these CsPbX 3 nanowires is dependent on the atomic composition, where the obtained room-temperature Rabi splitting energy is ∼210 ± 13, 146 ± 9, and 103 ± 5 meV for the CsPbCl 3 , CsPbBr 3 , and CsPbI 3 nanowires, respectively. This work provides fundamental insights for the practical applications of all-inorganic perovskite CsPbX 3 nanowires in designing light-emitting devices and integrated nanophotonic systems.
Dolansky, Mary A; Schexnayder, Julie; Patrician, Patricia A; Sales, Anne
Although quality and safety competencies were developed and disseminated nearly a decade ago by the Quality and Safety Education for Nurses (QSEN) project, the uptake in schools of nursing has been slow. The use of implementation science methods may be useful to accelerate quality and safety competency integration in nursing education. The article includes a definition and description of implementation science methods and practical implementation strategies for nurse educators to consider when integrating the QSEN competencies into nursing curriculum.
NASA Astrophysics Data System (ADS)
Zhang, Y. Y.; Shao, Q. X.; Ye, A. Z.; Xing, H. T.; Xia, J.
2016-02-01
Integrated water system modeling is a feasible approach to understanding severe water crises in the world and promoting the implementation of integrated river basin management. In this study, a classic hydrological model (the time variant gain model: TVGM) was extended to an integrated water system model by coupling multiple water-related processes in hydrology, biogeochemistry, water quality, and ecology, and considering the interference of human activities. A parameter analysis tool, which included sensitivity analysis, autocalibration and model performance evaluation, was developed to improve modeling efficiency. To demonstrate the model performances, the Shaying River catchment, which is the largest highly regulated and heavily polluted tributary of the Huai River basin in China, was selected as the case study area. The model performances were evaluated on the key water-related components including runoff, water quality, diffuse pollution load (or nonpoint sources) and crop yield. Results showed that our proposed model simulated most components reasonably well. The simulated daily runoff at most regulated and less-regulated stations matched well with the observations. The average correlation coefficient and Nash-Sutcliffe efficiency were 0.85 and 0.70, respectively. Both the simulated low and high flows at most stations were improved when the dam regulation was considered. The daily ammonium-nitrogen (NH4-N) concentration was also well captured with the average correlation coefficient of 0.67. Furthermore, the diffuse source load of NH4-N and the corn yield were reasonably simulated at the administrative region scale. This integrated water system model is expected to improve the simulation performances with extension to more model functionalities, and to provide a scientific basis for the implementation in integrated river basin managements.
Quality of Life Training Curriculum: Choice, Integration, Advocacy.
ERIC Educational Resources Information Center
1991
The purpose of this quality of life training curriculum is to enhance staff's understanding of the concepts of choice, integration, and advocacy; the importance of these qualities; and how staff can promote these qualities within the daily lives of persons with developmental disabilities. The curriculum includes topics for group discussion and…
Adaptive weld control for high-integrity welding applications
NASA Technical Reports Server (NTRS)
Powell, Bradley W.
1993-01-01
An advanced adaptive control weld system for high-integrity welding applications is presented. The system consists of a state-of-the-art weld control subsystem, motion control subsystem, and sensor subsystem which closes the loop on the process. The adaptive control subsystem (ACS), which is required to totally close the loop on weld process control, consists of a multiprocessor system, data acquisition hardware, and three welding sensors which provide measurements from all areas around the torch in real time. The ACS acquires all 'measurables' and feeds offset trims back into the weld control and motion control subsystems to modify the 'controllables' in order to maintain a previously defined weld quality.
[The hybrid operating room. Home of high-end intraoperative imaging].
Gebhard, F; Riepl, C; Richter, P; Liebold, A; Gorki, H; Wirtz, R; König, R; Wilde, F; Schramm, A; Kraus, M
2012-02-01
A hybrid operating room must serve the medical needs of different highly specialized disciplines. It integrates interventional techniques for cardiovascular procedures and allows operations in the field of orthopaedic surgery, neurosurgery and maxillofacial surgery. The integration of all steps such as planning, documentation and the procedure itself saves time and precious resources. The best available imaging devices and user interfaces reduce the need for extensive personnel in the OR and facilitate new minimally invasive procedures. The immediate possibility of postoperative control images in CT-like quality enables the surgeon to react to problems during the same procedure without the need for later revision.
Artificial intelligence and robotics in high throughput post-genomics.
Laghaee, Aroosha; Malcolm, Chris; Hallam, John; Ghazal, Peter
2005-09-15
The shift of post-genomics towards a systems approach has offered an ever-increasing role for artificial intelligence (AI) and robotics. Many disciplines (e.g. engineering, robotics, computer science) bear on the problem of automating the different stages involved in post-genomic research with a view to developing quality assured high-dimensional data. We review some of the latest contributions of AI and robotics to this end and note the limitations arising from the current independent, exploratory way in which specific solutions are being presented for specific problems without regard to how these could be eventually integrated into one comprehensible integrated intelligent system.
NASA Astrophysics Data System (ADS)
Friedrich, Axel; Raabe, Helmut; Schiefele, Jens; Doerr, Kai Uwe
1999-07-01
In future aircraft cockpit designs SVS (Synthetic Vision System) databases will be used to display 3D physical and virtual information to pilots. In contrast to pure warning systems (TAWS, MSAW, EGPWS) SVS serve to enhance pilot spatial awareness by 3-dimensional perspective views of the objects in the environment. Therefore all kind of aeronautical relevant data has to be integrated into the SVS-database: Navigation- data, terrain-data, obstacles and airport-Data. For the integration of all these data the concept of a GIS (Geographical Information System) based HQDB (High-Quality- Database) has been created at the TUD (Technical University Darmstadt). To enable database certification, quality- assessment procedures according to ICAO Annex 4, 11, 14 and 15 and RTCA DO-200A/EUROCAE ED76 were established in the concept. They can be differentiated in object-related quality- assessment-methods following the keywords accuracy, resolution, timeliness, traceability, assurance-level, completeness, format and GIS-related quality assessment methods with the keywords system-tolerances, logical consistence and visual quality assessment. An airport database is integrated in the concept as part of the High-Quality- Database. The contents of the HQDB are chosen so that they support both Flight-Guidance-SVS and other aeronautical applications like SMGCS (Surface Movement and Guidance Systems) and flight simulation as well. Most airport data are not available. Even though data for runways, threshold, taxilines and parking positions were to be generated by the end of 1997 (ICAO Annex 11 and 15) only a few countries fulfilled these requirements. For that reason methods of creating and certifying airport data have to be found. Remote sensing and digital photogrammetry serve as means to acquire large amounts of airport objects with high spatial resolution and accuracy in much shorter time than with classical surveying methods. Remotely sensed images can be acquired from satellite-platforms or aircraft-platforms. To achieve the highest horizontal accuracy requirements stated in ICAO Annex 14 for runway centerlines (0.50 meters), at the present moment only images acquired from aircraft based sensors can be used as source data. Still, ground reference by GCP (Ground Control-points) is obligatory. A DEM (Digital Elevation Model) can be created automatically in the photogrammetric process. It can be used as highly accurate elevation model for the airport area. The final verification of airport data is accomplished by independent surveyed runway- and taxiway- control-points. The concept of generation airport-data by means of remote sensing and photogrammetry was tested with the Stuttgart/Germany airport. The results proved that the final accuracy was within the accuracy specification defined by ICAO Annex 14.
Winsor, Geoffrey L; Griffiths, Emma J; Lo, Raymond; Dhillon, Bhavjinder K; Shay, Julie A; Brinkman, Fiona S L
2016-01-04
The Pseudomonas Genome Database (http://www.pseudomonas.com) is well known for the application of community-based annotation approaches for producing a high-quality Pseudomonas aeruginosa PAO1 genome annotation, and facilitating whole-genome comparative analyses with other Pseudomonas strains. To aid analysis of potentially thousands of complete and draft genome assemblies, this database and analysis platform was upgraded to integrate curated genome annotations and isolate metadata with enhanced tools for larger scale comparative analysis and visualization. Manually curated gene annotations are supplemented with improved computational analyses that help identify putative drug targets and vaccine candidates or assist with evolutionary studies by identifying orthologs, pathogen-associated genes and genomic islands. The database schema has been updated to integrate isolate metadata that will facilitate more powerful analysis of genomes across datasets in the future. We continue to place an emphasis on providing high-quality updates to gene annotations through regular review of the scientific literature and using community-based approaches including a major new Pseudomonas community initiative for the assignment of high-quality gene ontology terms to genes. As we further expand from thousands of genomes, we plan to provide enhancements that will aid data visualization and analysis arising from whole-genome comparative studies including more pan-genome and population-based approaches. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Enabling Science Integration through the Marine Geoscience Data System Media Bank
NASA Astrophysics Data System (ADS)
Leung, A.; Ferrini, V.; Arko, R.; Carbotte, S. M.; Goehring, L.; Simms, E.
2008-12-01
The Marine Geoscience Data System Media Bank (http://media.marine-geo.org) was constructed to enable the sharing of high quality images, illustrations and animations among members of the science community and to provide a new forum for education and public outreach (EPO). The initial focus of Media Bank was to serve Ridge 2000 research and EPO efforts, but it was constructed as a flexible system that could accommodate media from other multidisciplinary marine geoscience research initiatives. Media Bank currently contains digital photographs, maps, 3-D visualizations, and video clips from the Ridge 2000 and MARGINS focus sites as well as the Antarctic and Southern Ocean. We actively seek contributions of other high quality marine geoscience media for inclusion in Media Bank. Media Bank is driven by a relational database backend, enabling image browsing, sorting by category, keyword search functionality, and the creation of media galleries. All media are accompanied by a descriptive figure caption that provides easy access to expert knowledge to help foster data integration across disciplines as well as EPO efforts. In addition to access to high quality media, Media Bank also provides basic metadata including geographic position, investigator name and affiliation, as well as copyright information, and links to references and relevant data sets. Since media are tied to geospatial coordinates, a map-based interface is also provided for access to media.
Quality health care in the European Union thanks to competition law.
Fornaciari, Diego
2010-01-01
There are many biases concerning the application of competition law in health care. Quality concerns can however be integrated into competition law analysis. The aim of this paper is to identify the links between the application of competition law in the European Union and the right to quality health care and to point out the problems that arise when integrating quality concerns in competition law analysis. Guidelines must be issued and competition authorities must work together with institutions that have expertise in the field of health care quality measurement in order to integrate these dimensions in competition practice.
Bernard, André; Langille, Morgan; Hughes, Stephanie; Rose, Caren; Leddin, Desmond; Veldhuyzen van Zanten, Sander
2007-09-01
The Internet is a widely used information resource for patients with inflammatory bowel disease, but there is variation in the quality of Web sites that have patient information regarding Crohn's disease and ulcerative colitis. The purpose of the current study is to systematically evaluate the quality of these Web sites. The top 50 Web sites appearing in Google using the terms "Crohn's disease" or "ulcerative colitis" were included in the study. Web sites were evaluated using a (a) Quality Evaluation Instrument (QEI) that awarded Web sites points (0-107) for specific information on various aspects of inflammatory bowel disease, (b) a five-point Global Quality Score (GQS), (c) two reading grade level scores, and (d) a six-point integrity score. Thirty-four Web sites met the inclusion criteria, 16 Web sites were excluded because they were portals or non-IBD oriented. The median QEI score was 57 with five Web sites scoring higher than 75 points. The median Global Quality Score was 2.0 with five Web sites achieving scores of 4 or 5. The average reading grade level score was 11.2. The median integrity score was 3.0. There is marked variation in the quality of the Web sites containing information on Crohn's disease and ulcerative colitis. Many Web sites suffered from poor quality but there were five high-scoring Web sites.
Reforming funding for chronic illness: Medicare-CDM.
Swerissen, Hal; Taylor, Michael J
2008-02-01
Chronic diseases are a major challenge for the Australian health care system in terms of both the provision of quality care and expenditure, and these challenges will only increase in the future. Various programs have been instituted under the Medicare system to provide increased funding for chronic care, but essentially these programs still follow the traditional fee-for-service model. This paper proposes a realignment and extension of current Medicare chronic disease management programs into a framework that provides general practitioners and other health professionals with the necessary "tools" for high quality care planning and ongoing management, and incorporating international models of outcome-linked funding. The integration of social support services with the Medicare system is also a necessary step in providing high quality care for patients with complex needs requiring additional support.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Son, Seokki; Choi, Moonseok; Kim, Dohyung
2015-01-12
We deposited a metal oxide buffer layer before atomic layer deposition (ALD) of Al{sub 2}O{sub 3} onto exfoliated molybdenum disulfide (MoS{sub 2}) in order to accomplish enhanced integration. We demonstrate that even at a high temperature, functionalization of MoS{sub 2} by means of a metal oxide buffer layer can effectively provide nucleation sites for ALD precursors, enabling much better surface coverage of Al{sub 2}O{sub 3}. It is shown that using a metal oxide buffer layer not only allows high temperature ALD process, resulting in highly improved quality of Al{sub 2}O{sub 3}/MoS{sub 2} interface, but also leaves MoS{sub 2} intact.
Ge-Photodetectors for Si-Based Optoelectronic Integration
Wang, Jian; Lee, Sungjoo
2011-01-01
High speed photodetectors are a key building block, which allow a large wavelength range of detection from 850 nm to telecommunication standards at optical fiber band passes of 1.3–1.55 μm. Such devices are key components in several applications such as local area networks, board to board, chip to chip and intrachip interconnects. Recent technological achievements in growth of high quality SiGe/Ge films on Si wafers have opened up the possibility of low cost Ge-based photodetectors for near infrared communication bands and high resolution spectral imaging with high quantum efficiencies. In this review article, the recent progress in the development and integration of Ge-photodetectors on Si-based photonics will be comprehensively reviewed, along with remaining technological issues to be overcome and future research trends. PMID:22346598
Fast Batch Production of High-Quality Graphene Films in a Sealed Thermal Molecular Movement System.
Xu, Jianbao; Hu, Junxiong; Li, Qi; Wang, Rubing; Li, Weiwei; Guo, Yufen; Zhu, Yongbo; Liu, Fengkui; Ullah, Zaka; Dong, Guocai; Zeng, Zhongming; Liu, Liwei
2017-07-01
Chemical vapor deposition (CVD) growth of high-quality graphene has emerged as the most promising technique in terms of its integrated manufacturing. However, there lacks a controllable growth method for producing high-quality and a large-quantity graphene films, simultaneously, at a fast growth rate, regardless of roll-to-roll (R2R) or batch-to-batch (B2B) methods. Here, a stationary-atmospheric-pressure CVD (SAPCVD) system based on thermal molecular movement, which enables fast B2B growth of continuous and uniform graphene films on tens of stacked Cu(111) foils, with a growth rate of 1.5 µm s -1 , is demonstrated. The monolayer graphene of batch production is found to nucleate from arrays of well-aligned domains, and the films possess few defects and exhibit high carrier mobility up to 6944 cm 2 V -1 s -1 at room temperature. The results indicate that the SAPCVD system combined with single-domain Cu(111) substrates makes it possible to realize fast batch-growth of high-quality graphene films, which opens up enormous opportunities to use this unique 2D material for industrial device applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
An integrated view of data quality in Earth observation
Yang, X.; Blower, J. D.; Bastin, L.; Lush, V.; Zabala, A.; Masó, J.; Cornford, D.; Díaz, P.; Lumsden, J.
2013-01-01
Data quality is a difficult notion to define precisely, and different communities have different views and understandings of the subject. This causes confusion, a lack of harmonization of data across communities and omission of vital quality information. For some existing data infrastructures, data quality standards cannot address the problem adequately and cannot fulfil all user needs or cover all concepts of data quality. In this study, we discuss some philosophical issues on data quality. We identify actual user needs on data quality, review existing standards and specifications on data quality, and propose an integrated model for data quality in the field of Earth observation (EO). We also propose a practical mechanism for applying the integrated quality information model to a large number of datasets through metadata inheritance. While our data quality management approach is in the domain of EO, we believe that the ideas and methodologies for data quality management can be applied to wider domains and disciplines to facilitate quality-enabled scientific research. PMID:23230156
An integrated view of data quality in Earth observation.
Yang, X; Blower, J D; Bastin, L; Lush, V; Zabala, A; Masó, J; Cornford, D; Díaz, P; Lumsden, J
2013-01-28
Data quality is a difficult notion to define precisely, and different communities have different views and understandings of the subject. This causes confusion, a lack of harmonization of data across communities and omission of vital quality information. For some existing data infrastructures, data quality standards cannot address the problem adequately and cannot fulfil all user needs or cover all concepts of data quality. In this study, we discuss some philosophical issues on data quality. We identify actual user needs on data quality, review existing standards and specifications on data quality, and propose an integrated model for data quality in the field of Earth observation (EO). We also propose a practical mechanism for applying the integrated quality information model to a large number of datasets through metadata inheritance. While our data quality management approach is in the domain of EO, we believe that the ideas and methodologies for data quality management can be applied to wider domains and disciplines to facilitate quality-enabled scientific research.
Levine, Deena R; Baker, Justin N; Wolfe, Joanne; Lehmann, Leslie E; Ullrich, Christina
2017-09-01
In the intense, cure-oriented setting of hematopoietic stem-cell transplantation (HSCT), delivery of high-quality palliative and end-of-life care is a unique challenge. Although HSCT affords patients a chance for cure, it carries a significant risk of morbidity and mortality. During HSCT, patients usually experience high symptom burden and a significant decrease in quality of life that can persist for long periods. When morbidity is high and the chance of cure remote, the tendency after HSCT is to continue intensive medical interventions with curative intent. The nature of the complications and overall condition of some patients may render survival an unrealistic goal and, as such, continuation of artificial life-sustaining measures in these patients may prolong suffering and preclude patient and family preparation for end of life. Palliative care focuses on the well-being of patients with life-threatening conditions and their families, irrespective of the goals of care or anticipated outcome. Although not inherently at odds with HSCT, palliative care historically has been rarely offered to HSCT recipients. Recent evidence suggests that HSCT recipients would benefit from collaborative efforts between HSCT and palliative care services, particularly when initiated early in the transplantation course. We review palliative and end-of-life care in HSCT and present models for integrating palliative care into HSCT care. With open communication, respect for roles, and a spirit of collaboration, HSCT and palliative care can effectively join forces to provide high-quality, multidisciplinary care for these highly vulnerable patients and their families.
SU-F-J-143: Initial Assessment of Image Quality of An Integrated MR-Linac System with ACR Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Fuller, C; Yung, J
Purpose/Objective(s): To assess the image quality of an integrated MR-Linac system and compare with other MRI systems that are primarily used for diagnostic purposes. Materials/Methods: An ACR MRI quality control (QC) phantom was used to evaluate the image quality of a fully integrated 1.5T MRI-Linac system recently installed at our institution. This system has a new split magnet design which gives the magnetic field strength of 1.5T. All images were acquired with a set of phased-array surface coils which are designed to have minimal attention of radiation beam. The anterior coil rests on a coil holder which keeps the anteriormore » coil’s position consistent for QA purposes. The posterior coil is imbedded in the patient couch. Multiple sets of T1, T2/PD images were acquired using the protocols as prescribed by the ACR on three different dates, ranging 3 months apart. Results: The geometric distortion are within 0.5 mm in the axial scans and within 1mm in the saggital (z-direction) scans. Slice thickness accuracy, image uniformity, ghosting ratio, high contrast detectability are comparable to other 1.5T diagnostic MRI scanners. The low-contrast object detectability are lower comparatively, which is a result of using the body array coil. Additionally, the beam’s-eye-view images (oblique coronal and saggital images) have minimal geometric distortion at all linac gantry angles tested. No observable changes or drift in image quality is found from images acquired 3 month apart. Conclusion: Despite the use of a body array surface coil, the image quality is comparable to that of an 1.5T MRI scanner and is of sufficient quality to pass the ACR MRI accreditation program. The geometric distortion of the MRI system of the integrated MR-Linac is within 1mm for an object size similar to the ACR phantom, sufficient for radiation therapy treatment purpose. The authors received corporate sponsored research grants from Elekta which is the vendor for the MR-Linac evaluated in this study.« less
Qualitative evaluation of titanium implant integration into bone by diffraction enhanced imaging.
Wagner, A; Sachse, A; Keller, M; Aurich, M; Wetzel, W-D; Hortschansky, P; Schmuck, K; Lohmann, M; Reime, B; Metge, J; Arfelli, F; Menk, R; Rigon, L; Muehleman, C; Bravin, A; Coan, P; Mollenhauer, J
2006-03-07
Diffraction enhanced imaging (DEI) uses refraction of x-rays at edges, which allows pronounced visualization of material borders and rejects scattering which often obscures edges and blurs images. Here, the first evidence is presented that, using DEI, a destruction-free evaluation of the quality of integration of metal implants into bone is possible. Experiments were performed in rabbits and sheep with model implants to investigate the option for DEI as a tool in implant research. The results obtained from DEI were compared to conventional histology obtained from the specimens. DE images allow the identification of the quality of ingrowth of bone into the hydroxyapatite layer of the implant. Incomplete integration of the implant with a remaining gap of less than 0.3 mm caused the presence of a highly refractive edge at the implant/bone border. In contrast, implants with bone fully grown onto the surface did not display a refractive signal. Therefore, the refractive signal could be utilized to diagnose implant healing and/or loosening.
Qualitative evaluation of titanium implant integration into bone by diffraction enhanced imaging
NASA Astrophysics Data System (ADS)
Wagner, A.; Sachse, A.; Keller, M.; Aurich, M.; Wetzel, W.-D.; Hortschansky, P.; Schmuck, K.; Lohmann, M.; Reime, B.; Metge, J.; Arfelli, F.; Menk, R.; Rigon, L.; Muehleman, C.; Bravin, A.; Coan, P.; Mollenhauer, J.
2006-03-01
Diffraction enhanced imaging (DEI) uses refraction of x-rays at edges, which allows pronounced visualization of material borders and rejects scattering which often obscures edges and blurs images. Here, the first evidence is presented that, using DEI, a destruction-free evaluation of the quality of integration of metal implants into bone is possible. Experiments were performed in rabbits and sheep with model implants to investigate the option for DEI as a tool in implant research. The results obtained from DEI were compared to conventional histology obtained from the specimens. DE images allow the identification of the quality of ingrowth of bone into the hydroxyapatite layer of the implant. Incomplete integration of the implant with a remaining gap of less than 0.3 mm caused the presence of a highly refractive edge at the implant/bone border. In contrast, implants with bone fully grown onto the surface did not display a refractive signal. Therefore, the refractive signal could be utilized to diagnose implant healing and/or loosening.
Pugh, Thomas J; Pokharel, Sajal S
The integration of multiparametric MRI into prostate brachytherapy has become a subject of interest over the past 2 decades. MRI directed high-dose-rate and low-dose-rate prostate brachytherapy offers the potential to improve treatment accuracy and standardize postprocedure quality. This article reviews the evidence to date on MRI utilization in prostate brachytherapy and postulates future pathways for MRI integration. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
2010-01-01
Background The large amount of high-throughput genomic data has facilitated the discovery of the regulatory relationships between transcription factors and their target genes. While early methods for discovery of transcriptional regulation relationships from microarray data often focused on the high-throughput experimental data alone, more recent approaches have explored the integration of external knowledge bases of gene interactions. Results In this work, we develop an algorithm that provides improved performance in the prediction of transcriptional regulatory relationships by supplementing the analysis of microarray data with a new method of integrating information from an existing knowledge base. Using a well-known dataset of yeast microarrays and the Yeast Proteome Database, a comprehensive collection of known information of yeast genes, we show that knowledge-based predictions demonstrate better sensitivity and specificity in inferring new transcriptional interactions than predictions from microarray data alone. We also show that comprehensive, direct and high-quality knowledge bases provide better prediction performance. Comparison of our results with ChIP-chip data and growth fitness data suggests that our predicted genome-wide regulatory pairs in yeast are reasonable candidates for follow-up biological verification. Conclusion High quality, comprehensive, and direct knowledge bases, when combined with appropriate bioinformatic algorithms, can significantly improve the discovery of gene regulatory relationships from high throughput gene expression data. PMID:20122245
Seok, Junhee; Kaushal, Amit; Davis, Ronald W; Xiao, Wenzhong
2010-01-18
The large amount of high-throughput genomic data has facilitated the discovery of the regulatory relationships between transcription factors and their target genes. While early methods for discovery of transcriptional regulation relationships from microarray data often focused on the high-throughput experimental data alone, more recent approaches have explored the integration of external knowledge bases of gene interactions. In this work, we develop an algorithm that provides improved performance in the prediction of transcriptional regulatory relationships by supplementing the analysis of microarray data with a new method of integrating information from an existing knowledge base. Using a well-known dataset of yeast microarrays and the Yeast Proteome Database, a comprehensive collection of known information of yeast genes, we show that knowledge-based predictions demonstrate better sensitivity and specificity in inferring new transcriptional interactions than predictions from microarray data alone. We also show that comprehensive, direct and high-quality knowledge bases provide better prediction performance. Comparison of our results with ChIP-chip data and growth fitness data suggests that our predicted genome-wide regulatory pairs in yeast are reasonable candidates for follow-up biological verification. High quality, comprehensive, and direct knowledge bases, when combined with appropriate bioinformatic algorithms, can significantly improve the discovery of gene regulatory relationships from high throughput gene expression data.
Wing, Steve; Horton, Rachel Avery; Muhammad, Naeema; Grant, Gary R.; Tajik, Mansoureh; Thu, Kendall
2008-01-01
The environmental justice movement has stimulated community-driven research about the living and working conditions of people of color and low-income communities. We describe an epidemiological study designed to link research with community education and organizing for social justice. In eastern North Carolina, high-density industrial swine production occurs in communities of low-income people and people of color. We investigated relationships between the resulting pollution and the health and quality of life of the hog operations’ neighbors. A repeat-measures longitudinal design, community involvement in data collection, and integration of qualitative and quantitative research methods helped promote data quality while providing opportunities for community education and organizing. Research could affect policy through its findings and its mobilization of communities. PMID:18556620
Zhang, Dongdong; Wei, Dali; Li, Qi; Ge, Xin; Guo, Xuefeng; Xie, Zaiku; Ding, Weiping
2014-01-01
For production of biodiesel from bio oils by heterogeneous catalysis, high performance catalysts of transesterification and the further utilization of glycerol have been the two points of research. The process seemed easy, however, has never been well established. Here we report a novel design of catalytic distillation using hierachically integrated CNTs-based holistic catalyst to figure out the two points in one process, which shows high performance both for the conversion of bio oils to biodiesel and, unexpectedly, for the conversion of glycerol to more valuable chemicals at the same time. The method, with integration of nano, meso to macro reactor, has overwhelming advantages over common technologies using liquid acids or bases to catalyze the reactions, which suffer from the high cost of separation and unsolved utilization of glycerol. PMID:24503897
NASA Astrophysics Data System (ADS)
Zhang, Dongdong; Wei, Dali; Li, Qi; Ge, Xin; Guo, Xuefeng; Xie, Zaiku; Ding, Weiping
2014-02-01
For production of biodiesel from bio oils by heterogeneous catalysis, high performance catalysts of transesterification and the further utilization of glycerol have been the two points of research. The process seemed easy, however, has never been well established. Here we report a novel design of catalytic distillation using hierachically integrated CNTs-based holistic catalyst to figure out the two points in one process, which shows high performance both for the conversion of bio oils to biodiesel and, unexpectedly, for the conversion of glycerol to more valuable chemicals at the same time. The method, with integration of nano, meso to macro reactor, has overwhelming advantages over common technologies using liquid acids or bases to catalyze the reactions, which suffer from the high cost of separation and unsolved utilization of glycerol.
All MBE grown InAs/GaAs quantum dot lasers on on-axis Si (001).
Kwoen, Jinkwan; Jang, Bongyong; Lee, Joohang; Kageyama, Takeo; Watanabe, Katsuyuki; Arakawa, Yasuhiko
2018-04-30
Directly grown III-V quantum dot (QD) laser on on-axis Si (001) is a good candidate for achieving monolithically integrated Si photonics light source. Nowadays, laser structures containing high quality InAs / GaAs QD are generally grown by molecular beam epitaxy (MBE). However, the buffer layer between the on-axis Si (001) substrate and the laser structure are usually grown by metal-organic chemical vapor deposition (MOCVD). In this paper, we demonstrate all MBE grown high-quality InAs/GaAs QD lasers on on-axis Si (001) substrates without using patterning and intermediate layers of foreign material.
Mapping the Collaborative Research Process
ERIC Educational Resources Information Center
Kochanek, Julie Reed; Scholz, Carrie; Garcia, Alicia N.
2015-01-01
Despite significant federal investments in the production of high-quality education research, the direct use of that research in policy and practice is not evident. Some education researchers are increasingly employing collaborative research models that use structures and processes to integrate practitioners into the research process in an effort…
38 CFR 36.4347 - Lender Appraisal Processing Program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subsequent office case review requirements, routine reviews of LAPP cases will be made by VA staff based upon..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
38 CFR 36.4347 - Lender Appraisal Processing Program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subsequent office case review requirements, routine reviews of LAPP cases will be made by VA staff based upon..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
38 CFR 36.4347 - Lender Appraisal Processing Program.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subsequent office case review requirements, routine reviews of LAPP cases will be made by VA staff based upon..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
38 CFR 36.4347 - Lender Appraisal Processing Program.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subsequent office case review requirements, routine reviews of LAPP cases will be made by VA staff based upon..., that its activities do not deviate from high standards of integrity. The quality control system must include frequent, periodic audits that specifically address the appraisal review activity. These audits...
Biotelemetry system for ambulatory patients
NASA Technical Reports Server (NTRS)
Fryer, T. B.
1978-01-01
Compact transmitter for multichannel telemetry of medical data is carried in patient's belt. Pulse-code modulation (PCM), is used for high-quality signal, and low-power CMOS integrated circuits make miniaturization possible. Transmitter is useful for electro-encephalograms (EEG) and electro-cardiograms (EKG) and other biomedical patient-monitoring situations.
Modernizing Career and Technical Education Programs
ERIC Educational Resources Information Center
Drage, Karen
2009-01-01
High-quality career and technical education (CTE) programs can launch America's future competitiveness through increased student engagement, the innovative integration of traditional academic courses, and by meeting the needs of both employers and the economy as a whole. American students failing to keep pace with their international counterparts…
Yeung, C H T; Santesso, N; Zeraatkar, D; Wang, A; Pai, M; Sholzberg, M; Schünemann, H J; Iorio, A
2016-07-01
Integrated care models have been adopted for individuals with chronic conditions and for persons with rare diseases, such as haemophilia. To summarize the evidence from reviews for the effects of integrated multidisciplinary care for chronic conditions in adults and to provide an example of using this evidence to make recommendations for haemophilia care. We searched MEDLINE, EMBASE, CINAHL and Cochrane Database of Systematic Reviews up to January 2016, and reviewed reference lists of retrieved papers. Systematic reviews of at least one randomized study, on adults with non-communicable chronic conditions. Two investigators independently assessed eligibility and extracted data. Quality of reviews was assessed using ROBIS, and the evidence assessed using GRADE. We included seven reviews reporting on three chronic conditions. We found low to high quality evidence. Integrated care results in a reduction in mortality; likely a reduction in emergency visits and an improvement in function; little to no difference in quality of life, but shorter hospital stays; and may result in little to no difference in missed days of school or work. No studies reported educational attainment, or patient adherence and knowledge. When used for haemophilia, judgment about the indirectness of the evidence was driven by disease, intervention or outcome characteristics. This overview provides the most up to date evidence on integrated multidisciplinary care for chronic conditions in adults, and an example of how it can be used for guidelines in rare diseases. © 2016 John Wiley & Sons Ltd.
Didelot, Audrey; Kotsopoulos, Steve K; Lupo, Audrey; Pekin, Deniz; Li, Xinyu; Atochin, Ivan; Srinivasan, Preethi; Zhong, Qun; Olson, Jeff; Link, Darren R; Laurent-Puig, Pierre; Blons, Hélène; Hutchison, J Brian; Taly, Valerie
2013-05-01
Assessment of DNA integrity and quantity remains a bottleneck for high-throughput molecular genotyping technologies, including next-generation sequencing. In particular, DNA extracted from paraffin-embedded tissues, a major potential source of tumor DNA, varies widely in quality, leading to unpredictable sequencing data. We describe a picoliter droplet-based digital PCR method that enables simultaneous detection of DNA integrity and the quantity of amplifiable DNA. Using a multiplex assay, we detected 4 different target lengths (78, 159, 197, and 550 bp). Assays were validated with human genomic DNA fragmented to sizes of 170 bp to 3000 bp. The technique was validated with DNA quantities as low as 1 ng. We evaluated 12 DNA samples extracted from paraffin-embedded lung adenocarcinoma tissues. One sample contained no amplifiable DNA. The fractions of amplifiable DNA for the 11 other samples were between 0.05% and 10.1% for 78-bp fragments and ≤1% for longer fragments. Four samples were chosen for enrichment and next-generation sequencing. The quality of the sequencing data was in agreement with the results of the DNA-integrity test. Specifically, DNA with low integrity yielded sequencing results with lower levels of coverage and uniformity and had higher levels of false-positive variants. The development of DNA-quality assays will enable researchers to downselect samples or process more DNA to achieve reliable genome sequencing with the highest possible efficiency of cost and effort, as well as minimize the waste of precious samples. © 2013 American Association for Clinical Chemistry.
Qin, Fei; Meng, Zi-Ming; Zhong, Xiao-Lan; Liu, Ye; Li, Zhi-Yuan
2012-06-04
We present a versatile technique based on nano-imprint lithography to fabricate high-quality semiconductor-polymer compound nonlinear photonic crystal (NPC) slabs. The approach allows one to infiltrate uniformly polystyrene materials that possess large Kerr nonlinearity and ultrafast nonlinear response into the cylindrical air holes with diameter of hundred nanometers that are perforated in silicon membranes. Both the structural characterization via the cross-sectional scanning electron microscopy images and the optical characterization via the transmission spectrum measurement undoubtedly show that the fabricated compound NPC samples have uniform and dense polymer infiltration and are of high quality in optical properties. The compound NPC samples exhibit sharp transmission band edges and nondegraded high quality factor of microcavities compared with those in the bare silicon PC. The versatile method can be expanded to make general semiconductor-polymer hybrid optical nanostructures, and thus it may pave the way for reliable and efficient fabrication of ultrafast and ultralow power all-optical tunable integrated photonic devices and circuits.
Improving yield and performance in ZnO thin-film transistors made using selective area deposition.
Nelson, Shelby F; Ellinger, Carolyn R; Levy, David H
2015-02-04
We describe improvements in both yield and performance for thin-film transistors (TFTs) fabricated by spatial atomic layer deposition (SALD). These improvements are shown to be critical in forming high-quality devices using selective area deposition (SAD) as the patterning method. Selective area deposition occurs when the precursors for the deposition are prevented from reacting with some areas of the substrate surface. Controlling individual layer quality and the interfaces between layers is essential for obtaining good-quality thin-film transistors and capacitors. The integrity of the gate insulator layer is particularly critical, and we describe a method for forming a multilayer dielectric using an oxygen plasma treatment between layers that improves crossover yield. We also describe a method to achieve improved mobility at the important interface between the semiconductor and the gate insulator by, conversely, avoiding oxygen plasma treatment. Integration of the best designs results in wide design flexibility, transistors with mobility above 15 cm(2)/(V s), and good yield of circuits.
Curved Microneedle Array-Based sEMG Electrode for Robust Long-Term Measurements and High Selectivity
Kim, Minjae; Kim, Taewan; Kim, Dong Sung; Chung, Wan Kyun
2015-01-01
Surface electromyography is widely used in many fields to infer human intention. However, conventional electrodes are not appropriate for long-term measurements and are easily influenced by the environment, so the range of applications of sEMG is limited. In this paper, we propose a flexible band-integrated, curved microneedle array electrode for robust long-term measurements, high selectivity, and easy applicability. Signal quality, in terms of long-term usability and sensitivity to perspiration, was investigated. Its motion-discriminating performance was also evaluated. The results show that the proposed electrode is robust to perspiration and can maintain a high-quality measuring ability for over 8 h. The proposed electrode also has high selectivity for motion compared with a commercial wet electrode and dry electrode. PMID:26153773
Nanogranular soft magnetic material and on-package integrated inductors
NASA Astrophysics Data System (ADS)
Li, Liangliang
2007-12-01
Integrated inductors used in electronic circuits are mainly spiral-shaped aluminum devices fabricated on Si chip. They have several disadvantages---large silicon area consumption, high DC resistance and high cost. An attractive approach to address these issues is directly integrating inductors into package substrates, which provide plenty of usage area, low resistance and low cost. The goals of this dissertation are designing and fabricating magnetic and air-core inductors with characteristic low resistance and high quality factor on package substrates. The research work includes three parts which are summarized below. First, the CoFeHfO nanogranular magnetic material developed on Si wafers and package substrates by pulsed DC reactive sputtering were investigated. On Si wafers, the optimized CoFeHfO film has soft magnetic properties. On printed circuit board (PCB) substrates, these magnetic properties degrade due to the rough surface. Surface planarization such as chemical-mechanical polishing can be applied on PCB substrates to reduce the surface roughness and hence improve these properties. Second, on-package inductors with small resistances and high quality factors were designed, fabricated, measured and analyzed. Air-core and magnetic inductors (20 design variations) were built on 8-inch PCB substrates. The DC resistances of these inductors are less than 12 mO, one of the lowest values ever reported. The maximum quality factors can be as large as ˜80 at around 1 GHz for the air-core inductors and ˜25 at 200 MHz for the magnetic inductors. Third, inductor simulation was carried out to study the effects of magnetic materials on the properties of inductors using the Ansoft HFSS software package. The measurement data for the permeability spectra of the CoFeHfO film and the tensor nature of the permeability were taken into account in the simulation. The simulation results matched the experimental data for the inductances, resistances and quality factors. This established an accurate method for modeling high-frequency magnetic devices. Using this method, an inductor with a closed magnetic core was studied by varying the geometry of the core and copper coil. It has been found that the inductance of this inductor depends strongly on whether the permeability of the magnetic core is isotropic or anisotropic.
Monitoring of laser material processing using machine integrated low-coherence interferometry
NASA Astrophysics Data System (ADS)
Kunze, Rouwen; König, Niels; Schmitt, Robert
2017-06-01
Laser material processing has become an indispensable tool in modern production. With the availability of high power pico- and femtosecond laser sources, laser material processing is advancing into applications, which demand for highest accuracies such as laser micro milling or laser drilling. In order to enable narrow tolerance windows, a closedloop monitoring of the geometrical properties of the processed work piece is essential for achieving a robust manufacturing process. Low coherence interferometry (LCI) is a high-precision measuring principle well-known from surface metrology. In recent years, we demonstrated successful integrations of LCI into several different laser material processing methods. Within this paper, we give an overview about the different machine integration strategies, that always aim at a complete and ideally telecentric integration of the measurement device into the existing beam path of the processing laser. Thus, highly accurate depth measurements within machine coordinates and a subsequent process control and quality assurance are possible. First products using this principle have already found its way to the market, which underlines the potential of this technology for the monitoring of laser material processing.
[Intelligent watch system for health monitoring based on Bluetooth low energy technology].
Wang, Ji; Guo, Hailiang; Ren, Xiaoli
2017-08-01
According to the development status of wearable technology and the demand of intelligent health monitoring, we studied the multi-function integrated smart watches solution and its key technology. First of all, the sensor technology with high integration density, Bluetooth low energy (BLE) and mobile communication technology were integrated and used in develop practice. Secondly, for the hardware design of the system in this paper, we chose the scheme with high integration density and cost-effective computer modules and chips. Thirdly, we used real-time operating system FreeRTOS to develop the friendly graphical interface interacting with touch screen. At last, the high-performance application software which connected with BLE hardware wirelessly and synchronized data was developed based on android system. The function of this system included real-time calendar clock, telephone message, address book management, step-counting, heart rate and sleep quality monitoring and so on. Experiments showed that the collecting data accuracy of various sensors, system data transmission capacity, the overall power consumption satisfy the production standard. Moreover, the system run stably with low power consumption, which could realize intelligent health monitoring effectively.
Elements of integrated care approaches for older people: a review of reviews.
Briggs, Andrew M; Valentijn, Pim P; Thiyagarajan, Jotheeswaran A; Araujo de Carvalho, Islene
2018-04-07
The World Health Organization (WHO) recently proposed an Integrated Care for Older People approach to guide health systems and services in better supporting functional ability of older people. A knowledge gap remains in the key elements of integrated care approaches used in health and social care delivery systems for older populations. The objective of this review was to identify and describe the key elements of integrated care models for elderly people reported in the literature. Review of reviews using a systematic search method. A systematic search was performed in MEDLINE and the Cochrane database in June 2017. Reviews of interventions aimed at care integration at the clinical (micro), organisational/service (meso) or health system (macro) levels for people aged ≥60 years were included. Non-Cochrane reviews published before 2015 were excluded. Reviews were assessed for quality using the Assessment of Multiple Systematic Reviews (AMSTAR) 1 tool. Fifteen reviews (11 systematic reviews, of which six were Cochrane reviews) were included, representing 219 primary studies. Three reviews (20%) included only randomised controlled trials (RCT), while 10 reviews (65%) included both RCTs and non-RCTs. The region where the largest number of primary studies originated was North America (n=89, 47.6%), followed by Europe (n=60, 32.1%) and Oceania (n=31, 16.6%). Eleven (73%) reviews focused on clinical 'micro' and organisational 'meso' care integration strategies. The most commonly reported elements of integrated care models were multidisciplinary teams, comprehensive assessment and case management. Nurses, physiotherapists, general practitioners and social workers were the most commonly reported service providers. Methodological quality was variable (AMSTAR scores: 1-11). Seven (47%) reviews were scored as high quality (AMSTAR score ≥8). Evidence of elements of integrated care for older people focuses particularly on micro clinical care integration processes, while there is a relative lack of information regarding the meso organisational and macro system-level care integration strategies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Quality Enhancement on E-Learning
ERIC Educational Resources Information Center
Ossiannilsson, E. S. I.
2012-01-01
Purpose: Benchmarking, a method for quality assurance has not been very commonly used in higher education with regard to e-learning. Today, e-learning is an integral part of higher education, and so should also be an integral part of quality assurance systems. However, quality indicators, benchmarks and critical success factors on e-learning have…
ERIC Educational Resources Information Center
Moore, Michael G.
2016-01-01
A systems methodology was employed to design and deliver a highly successful demonstration of the effectiveness of distance education as a means of providing high quality training to tens of thousands of teachers in the most remote areas of Brazil. Key elements in the success of the program were significant funding, top political buy-in, and…
NASA Technical Reports Server (NTRS)
Robinson, E. A.
1973-01-01
Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.
DOT National Transportation Integrated Search
1997-04-01
The Land Use, Air Quality, and Transportation Integrated Modeling Environment (LATIME) represents an integrated approach to computer modeling and simulation of land use allocation, travel demand, and mobile source emissions for the Albuquerque, New M...
Flight test experience with high-alpha control system techniques on the F-14 airplane
NASA Technical Reports Server (NTRS)
Gera, J.; Wilson, R. J.; Enevoldson, E. K.; Nguyen, L. T.
1981-01-01
Improved handling qualities of fighter aircraft at high angles of attack can be provided by various stability and control augmentation techniques. NASA and the U.S. Navy are conducting a joint flight demonstration of these techniques on an F-14 airplane. This paper reports on the flight test experience with a newly designed lateral-directional control system which suppresses such high angle of attack handling qualities problems as roll reversal, wing rock, and directional divergence while simultaneously improving departure/spin resistance. The technique of integrating a piloted simulation into the flight program was used extensively in this program. This technique had not been applied previously to high angle of attack testing and required the development of a valid model to simulate the test airplane at extremely high angles of attack.
Ragsdale, Rob; Vowinkel, Eric; Porter, Dwayne; Hamilton, Pixie; Morrison, Ru; Kohut, Josh; Connell, Bob; Kelsey, Heath; Trowbridge, Phil
2011-01-01
The Integrated Ocean Observing System (IOOS®) Regional Associations and Interagency Partners hosted a water quality workshop in January 2010 to discuss issues of nutrient enrichment and dissolved oxygen depletion (hypoxia), harmful algal blooms (HABs), and beach water quality. In 2007, the National Water Quality Monitoring Council piloted demonstration projects as part of the National Water Quality Monitoring Network (Network) for U.S. Coastal Waters and their Tributaries in three IOOS Regional Associations, and these projects are ongoing. Examples of integrated science-based solutions to water quality issues of major concern from the IOOS regions and Network demonstration projects are explored in this article. These examples illustrate instances where management decisions have benefited from decision-support tools that make use of interoperable data. Gaps, challenges, and outcomes are identified, and a proposal is made for future work toward a multiregional water quality project for beach water quality.
Gaussian-reflectivity mirror resonator for a high-power transverse-flow CO2 laser.
Ling, Dongxiong; Chen, Junruo; Li, Junchang
2006-05-01
A Gaussian-reflectivity mirror resonator is proposed to achieve high-quality laser beams. To analyze the laser fields in a Gaussian-reflectivity mirror resonator, the diffraction integral equations of a Gaussian-reflectivity mirror resonator are converted to the finite-sum matrix equations. Consequently, according to the Fox-Li laser self-reproducing principle, we describe the mode fields and their losses in the proposed resonator as eigenvectors and eigenvalues of a transfer matrix. The conclusion can be drawn from the numerical results that, if a Gaussian-reflectivity mirror is adopted for a plano-concave resonator, a fundamental mode can easily be obtained from a transverse-flow CO2 laser and high-quality laser beams can be expected.
Flat dielectric metasurface lens array for three dimensional integral imaging
NASA Astrophysics Data System (ADS)
Zhang, Jianlei; Wang, Xiaorui; Yang, Yi; Yuan, Ying; Wu, Xiongxiong
2018-05-01
In conventional integral imaging, the singlet refractive lens array limits the imaging performance due to its prominent aberrations. Different from the refractive lens array relying on phase modulation via phase change accumulated along the optical paths, metasurfaces composed of nano-scatters can produce phase abrupt over the scale of wavelength. In this letter, we propose a novel lens array consisting of two neighboring flat dielectric metasurfaces for integral imaging system. The aspherical phase profiles of the metasurfaces are optimized to improve imaging performance. The simulation results show that our designed 5 × 5 metasurface-based lens array exhibits high image quality at designed wavelength 865 nm.
NASA Technical Reports Server (NTRS)
Panek, Joseph W.
2001-01-01
The proper operation of the Electronically Scanned Pressure (ESP) System critical to accomplish the following goals: acquisition of highly accurate pressure data for the development of aerospace and commercial aviation systems and continuous confirmation of data quality to avoid costly, unplanned, repeat wind tunnel or turbine testing. Standard automated setup and checkout routines are necessary to accomplish these goals. Data verification and integrity checks occur at three distinct stages, pretest pressure tubing and system checkouts, daily system validation and in-test confirmation of critical system parameters. This paper will give an overview of the existing hardware, software and methods used to validate data integrity.
NASA Astrophysics Data System (ADS)
Ioan, M.-R.
2018-01-01
Almost all optical diagnostic systems associated with classical particle accelerators or with new state-of-the-art particle accelerators, such as those developed within the European Collaboration ELI-NP (Extreme Light Infrastructure-Nuclear Physics) (involving extreme power laser beams), contain in their infrastructure high quality laser mirrors, used for their reflectivity and/or their partial transmittance. These high quality mirrors facilitate the extraction and handling of optical signals. When optical mirrors are exposed to high energy ionizing radiation fields, their optical and structural properties will change over time and their functionality will be affected, meaning that they will provide imprecise information. In some experiments, being exposed to mixed laser and accelerated particle beams, the deterioration of laser mirrors is even more acute, since the destruction mechanisms of both types of beams are cumulated. The main task of the work described in this paper was to find a novel specific method to analyse and highlight such degradation processes. By using complex fractal techniques integrated in a MATLAB code, the effects induced by alpha radiation to laser mirrors were studied. The fractal analysis technique represents an alternative approach to the classical Euclidean one. It can be applied for the characterization of the defects occurred in mirrors structure due to their exposure to high energy alpha particle beams. The proposed method may be further integrated into mirrors manufacturing process, as a testing instrument, to obtain better quality mirrors (enhanced resistance to high energy ionizing beams) by using different types of reflective coating materials and different deposition techniques. Moreover, the effect of high energy alpha ionizing particles on the optical properties of the exposed laser mirrors was studied by using spectrophotometric techniques.
Integration of upper air data in the MeteoSwiss Data Warehouse
NASA Astrophysics Data System (ADS)
Musa, M.; Haeberli, Ch.; Ruffieux, D.
2010-09-01
Over the last 10 years MeteoSwiss established a Data Warehouse in order to get one single, integrated data platform for all kinds of meteorological and climatological data. In the MeteoSwiss Data Warehouse data and metadata are hold in a metadata driven relational database. To reach this goal, we started with the integration of the actual and historical data from our surface stations in a first step, including routines for aggregation and calculation and the implementation of enhanced Quality Control tools. In 2008 we started with the integration of actual and historical upper air data like soundings (PTU, Wind and Ozone), any kind of profilers like wind profiler or radiometer, profiles calculated from numerical weather models and AMDAR data in the Data Warehouse. The dataset includes also high resolution sounding data from the station Payerne and TEMP data from 20 European stations since 1942. A critical point was to work out a concept for the general architecture which could deal with all different types of data. While integrating the data itself all metadata of the aerological station Payerne was transferred and imported in the central metadata repository of the Data Warehouse. The implementation of the real time and daily QC tools as well as the routines for aggregation and calculation were realized in an analog way as for the surface data. The Quality Control tools include plausibility tests like limit tests, consistency tests in the same level and vertical consistency tests. From the beginning it was the aim to support the MeteoSwiss integration strategy which deals with all aspects of integration like various observing technologies and platforms, observing systems outside MeteoSwiss and the data and metadata itself. This kind of integration comprises all aspects of "Enterprise Data Integration". After the integration, the historical as well as the actual upper air data are now available for the climatologists and meteorologists with standardized access for data retrieving and visualization. We are convinced making these data accessible for the scientist is a good contribution to a better understanding of high resolution climatology.
Research on the performance evaluation of agricultural products supply chain integrated operation
NASA Astrophysics Data System (ADS)
Jiang, Jiake; Wang, Xifu; Liu, Yang
2017-04-01
The agricultural product supply chain integrated operation can ensure the quality and efficiency of agricultural products, and achieve the optimal goal of low cost and high service. This paper establishes a performance evaluation index system of agricultural products supply chain integration operation based on the development status of agricultural products and SCOR, BSC and KPI model. And then, we constructing rough set theory and BP neural network comprehensive evaluation model with the aid of Rosetta and MATLAB tools and the case study is about the development of agricultural products integrated supply chain in Jing-Jin-Ji region. And finally, we obtain the corresponding performance results, and give some improvement measures and management recommendations to the managers.
NASA Astrophysics Data System (ADS)
Budy, Phaedra; Baker, Matthew; Dahle, Samuel K.
2011-10-01
Anthropogenic impairment of water bodies represents a global environmental concern, yet few attempts have successfully linked fish performance to thermal habitat suitability and fewer have distinguished co-varying water quality constraints. We interfaced fish bioenergetics, field measurements, and Thermal Remote Imaging to generate a spatially-explicit, high-resolution surface of fish growth potential, and next employed a structured hypothesis to detect relationships among measures of fish performance and co-varying water quality constraints. Our thermal surface of fish performance captured the amount and spatial-temporal arrangement of thermally-suitable habitat for three focal species in an extremely heterogeneous reservoir, but interpretation of this pattern was initially confounded by seasonal covariation of water residence time and water quality. Subsequent path analysis revealed that in terms of seasonal patterns in growth potential, catfish and walleye responded to temperature, positively and negatively, respectively; crappie and walleye responded to eutrophy (negatively). At the high eutrophy levels observed in this system, some desired fishes appear to suffer from excessive cultural eutrophication within the context of elevated temperatures whereas others appear to be largely unaffected or even enhanced. Our overall findings do not lead to the conclusion that this system is degraded by pollution; however, they do highlight the need to use a sensitive focal species in the process of determining allowable nutrient loading and as integrators of habitat suitability across multiple spatial and temporal scales. We provide an integrated approach useful for quantifying fish growth potential and identifying water quality constraints on fish performance at spatial scales appropriate for whole-system management.
NASA Astrophysics Data System (ADS)
Song, Wei; Zhang, Rui; Zhang, Hao F.; Wei, Qing; Cao, Wenwu
2012-12-01
The physiological and pathological properties of retina are closely associated with various optical contrasts. Hence, integrating different ophthalmic imaging technologies is more beneficial in both fundamental investigation and clinical diagnosis of several blinding diseases. Recently, photoacoustic ophthalmoscopy (PAOM) was developed for in vivo retinal imaging in small animals, which demonstrated the capability of imaging retinal vascular networks and retinal pigment epithelium (RPE) at high sensitivity. We combined PAOM with traditional imaging modalities, such as fluorescein angiography (FA), spectral-domain optical coherence tomography (SD-OCT), and auto-fluorescence scanning laser ophthalmoscopy (AF-SLO), for imaging rats and mice. The multimodal imaging system provided more comprehensive evaluation of the retina based on the complementary imaging contrast mechanisms. The high-quality retinal images show that the integrated ophthalmic imaging system has great potential in the investigation of blinding disorders.
Min, Jun Ki; Cha, Jae Myung; Cho, Yu Kyung; Kim, Jie Hyun; Yoon, Soon Man; Im, Jong Pil; Jung, Yunho; Moon, Jeong Seop; Kim, Jin Oh; Jeen, Yoon Tae
2018-05-25
Gastroscopy and colonoscopy are widely used for the early diagnosis of stomach and colorectal cancer. The present revision integrates recent data regarding previous quality indicators and novel indicators suggested for gastroscopy and colonoscopy procedures for the National Cancer Screening Program in Korea. The new indicators, developed by the Quality Improvement Committee of the Korean Society for Gastrointestinal Endoscopy, vary in the level of supporting evidence, and most are based solely on expert opinion. Updated indicators validated by clinical research were prioritized, but were chosen by expert consensus when such studies were absent. The resultant quality indicators were graded according to the levels of consensus and recommendations. The updated indicators will provide a relevant guideline for high-quality endoscopy. The future direction of quality indicator development should include relevant outcome measures and an evidence-based approach to support proposed performance targets.
Fostering a Commitment to Quality: Best Practices in Safety-net Hospitals.
Hochman, Michael; Briggs-Malonson, Medell; Wilkes, Erin; Bergman, Jonathan; Daskivich, Lauren Patty; Moin, Tannaz; Brook, Ilanit; Ryan, Gery W; Brook, Robert H; Mangione, Carol M
2016-01-01
In 2007, the Martin Luther King, Jr.-Harbor Hospital (MLK-Harbor), which served a large safety-net population in South Los Angeles, closed due to quality challenges. Shortly thereafter, an agreement was made to establish a new hospital, Martin Luther King, Jr. Community Hospital (MLKCH), to serve the unmet needs of the community. To assist the newly appointed MLKCH Board of Directors in building a culture of quality, we conducted a series of interviews with five high-performing hospital systems. In this report, we describe our findings. The hospitals we interviewed achieved a culture of quality by: 1) developing guiding principles that foster quality; 2) hiring and retaining personnel who are stewards of quality; 3) promoting efficient resource utilization; 4) developing a well-organized quality improvement infrastructure; and 5) cultivating integrated, patient-centric care. The institutions highlighted in this report provide important lessons for MLKCH and other safety-net institutions.
Strategic deployment of CHO expression platforms to deliver Pfizer's Monoclonal Antibody Portfolio.
Scarcelli, John J; Shang, Tanya Q; Iskra, Tim; Allen, Martin J; Zhang, Lin
2017-11-01
Development of stable cell lines for expression of large-molecule therapeutics represents a significant portion of the time and effort required to advance a molecule to enabling regulatory toxicology studies and clinical evaluation. Our development strategy employs two different approaches for cell line development based on the needs of a particular project: a random integration approach for projects where high-level expression is critical, and a site-specific integration approach for projects in which speed and reduced employee time spend is a necessity. Here we describe both our random integration and site-specific integration platforms and their applications in support of monoclonal antibody development and production. We also compare product quality attributes of monoclonal antibodies produced with a nonclonal cell pool or clonal cell lines derived from the two platforms. Our data suggests that material source (pools vs. clones) does not significantly alter the examined product quality attributes. Our current practice is to leverage this observation with our site-specific integration platform, where material generated from cell pools is used for an early molecular assessment of a given candidate to make informed decisions around development strategy. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1463-1467, 2017. © 2017 American Institute of Chemical Engineers.
Effects of side-stick controllers on rotorcraft handling qualities for terrain flight
NASA Technical Reports Server (NTRS)
Aiken, E. W.
1985-01-01
Pertinent fixed and rotary-wing feasibility studies and handling-qualities research programs are reviewed and the effects of certain controller characteristics on handling qualities for specific rotorcraft flight tasks are summarized. The effects of the controller force-deflection relationship and the number of controlled axes that are integrated in a single controller are examined. Simulation studies were conducted which provide a significant part of the available handling qualities data. The studies demonstrate the feasibility of using a single, properly designed, limited-displacement, multiaxis controller for certain relatively routine flight tasks in a two-crew rotorcraft with nominal levels of stability and control augmentation with a high degree of reliability are incorporated, separated three or two-axis controller configurations are required for acceptable handling qualities.
Pella, A; Riboldi, M; Tagaste, B; Bianculli, D; Desplanques, M; Fontana, G; Cerveri, P; Seregni, M; Fattori, G; Orecchia, R; Baroni, G
2014-08-01
In an increasing number of clinical indications, radiotherapy with accelerated particles shows relevant advantages when compared with high energy X-ray irradiation. However, due to the finite range of ions, particle therapy can be severely compromised by setup errors and geometric uncertainties. The purpose of this work is to describe the commissioning and the design of the quality assurance procedures for patient positioning and setup verification systems at the Italian National Center for Oncological Hadrontherapy (CNAO). The accuracy of systems installed in CNAO and devoted to patient positioning and setup verification have been assessed using a laser tracking device. The accuracy in calibration and image based setup verification relying on in room X-ray imaging system was also quantified. Quality assurance tests to check the integration among all patient setup systems were designed, and records of daily QA tests since the start of clinical operation (2011) are presented. The overall accuracy of the patient positioning system and the patient verification system motion was proved to be below 0.5 mm under all the examined conditions, with median values below the 0.3 mm threshold. Image based registration in phantom studies exhibited sub-millimetric accuracy in setup verification at both cranial and extra-cranial sites. The calibration residuals of the OTS were found consistent with the expectations, with peak values below 0.3 mm. Quality assurance tests, daily performed before clinical operation, confirm adequate integration and sub-millimetric setup accuracy. Robotic patient positioning was successfully integrated with optical tracking and stereoscopic X-ray verification for patient setup in particle therapy. Sub-millimetric setup accuracy was achieved and consistently verified in daily clinical operation.
Effect of multiple cycles of freeze-thawing on the RNA quality of lung cancer tissues.
Yu, Keke; Xing, Jie; Zhang, Jie; Zhao, Ruiying; Zhang, Ye; Zhao, Lanxiang
2017-09-01
RNA degradation is a major problem in tissue banking. We explored the effect of thawing flash-frozen biospecimens on the quality and integrity of RNA for genetic testing as well as for other cancer research studies. The histological quality of the frozen tumor sections was evaluated by using hematoxylin and eosin staining. RNA extraction from 60 lung cancer tissue samples subjected to various freeze/thaw cycles was performed using the RNeasy Plus isolation kit. RNA integrity was assessed by using an Agilent bioanalyzer to obtain RNA integrity numbers (RIN). Furthermore, RNA from different groups was used for fluorescence Reverse transcription-polymerase chain reaction (RT-PCR) analysis of the echinoderm microtubule-associated protein-like 4 and anaplastic lymphoma kinase (EML4-ALK) fusion gene mutation to verify whether it can be used for research or clinical testing. Highly variable RIN values were observed among the samples, which showed no correlation with the number of freeze/thaw cycles conducted. However, after 3 freeze/thaw cycles (each thaw event lasted for 10 min), an increasing number of changes in peak intensity in RINs were observed. After 5 freeze/thaw cycles, RNA integrity decreased to approximately 35%. After 3 freeze/thaw cycles, the RNA could still be used for RT-PCR analysis of EML4-ALK fusion gene mutations; whereas those subjected to 5 freeze/thaw cycles could not. Limited (<3) freeze/thaw cycles did not adversely affect the quality of RNA extracted from tumor tissues and subsequent RT-PCR analysis. Our data could be utilized in the establishment of a standardized procedure for tissue biospecimen collection and storage.
An improved multi-exposure approach for high quality holographic femtosecond laser patterning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Chenchu; Hu, Yanlei, E-mail: huyl@ustc.edu.cn, E-mail: jwl@ustc.edu.cn; Li, Jiawen, E-mail: huyl@ustc.edu.cn, E-mail: jwl@ustc.edu.cn
High efficiency two photon polymerization through single exposure via spatial light modulator (SLM) has been used to decrease the fabrication time and rapidly realize various micro/nanostructures, but the surface quality remains a big problem due to the speckle noise of optical intensity distribution at the defocused plane. Here, a multi-exposure approach which used tens of computer generate holograms successively loaded on SLM is presented to significantly improve the optical uniformity without losing efficiency. By applying multi-exposure, we found that the uniformity at the defocused plane was increased from ∼0.02 to ∼0.6 according to our simulation. The fabricated two series ofmore » letters “HELLO” and “USTC” under single-and multi-exposure in our experiment also verified that the surface quality was greatly improved. Moreover, by this method, several kinds of beam splitters with high quality, e.g., 2 × 2, 5 × 5 Daman, and complex nonseperate 5 × 5, gratings were fabricated with both of high quality and short time (<1 min, 95% time-saving). This multi-exposure SLM-two-photon polymerization method showed the promising prospect in rapidly fabricating and integrating various binary optical devices and their systems.« less
POLYVIEW-MM: web-based platform for animation and analysis of molecular simulations
Porollo, Aleksey; Meller, Jaroslaw
2010-01-01
Molecular simulations offer important mechanistic and functional clues in studies of proteins and other macromolecules. However, interpreting the results of such simulations increasingly requires tools that can combine information from multiple structural databases and other web resources, and provide highly integrated and versatile analysis tools. Here, we present a new web server that integrates high-quality animation of molecular motion (MM) with structural and functional analysis of macromolecules. The new tool, dubbed POLYVIEW-MM, enables animation of trajectories generated by molecular dynamics and related simulation techniques, as well as visualization of alternative conformers, e.g. obtained as a result of protein structure prediction methods or small molecule docking. To facilitate structural analysis, POLYVIEW-MM combines interactive view and analysis of conformational changes using Jmol and its tailored extensions, publication quality animation using PyMol, and customizable 2D summary plots that provide an overview of MM, e.g. in terms of changes in secondary structure states and relative solvent accessibility of individual residues in proteins. Furthermore, POLYVIEW-MM integrates visualization with various structural annotations, including automated mapping of known inter-action sites from structural homologs, mapping of cavities and ligand binding sites, transmembrane regions and protein domains. URL: http://polyview.cchmc.org/conform.html. PMID:20504857
NASA Astrophysics Data System (ADS)
Kemiche, Malik; Lhuillier, Jérémy; Callard, Ségolène; Monat, Christelle
2018-01-01
We exploit slow light (high ng) modes in planar photonic crystals in order to design a compact cavity, which provides an attractive path towards the miniaturization of near-infrared integrated fast pulsed lasers. By applying dispersion engineering techniques, we can design structures with a low dispersion, as needed by mode-locking operation. Our basic InP SiO2 heterostructure is robust and well suited to integrated laser applications. We show that an optimized 30 μm long cavity design yields 9 frequency-equidistant modes with a FSR of 178 GHz within a 11.5 nm bandwidth, which could potentially sustain the generation of optical pulses shorter than 700 fs. In addition, the numerically calculated quality factors of these modes are all above 10,000, making them suitable for reaching laser operation. Thanks to the use of a high group index (28), this cavity design is almost one order of magnitude shorter than standard rib-waveguide based mode-locked lasers. The use of slow light modes in planar photonic crystal based cavities thus relaxes the usual constraints that tightly link the device size and the quality (peak power, repetition rate) of the pulsed laser signal.
Hefferman, Gerald M; Zhang, Fan; Nunnery, Michael J; Huang, He
2015-04-01
In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical integrated socket-sensor designs used to record electromyographic signals from within the sockets of transfemoral amputees. Four prototypical socket-sensor configurations were constructed and tested on a single transfemoral amputee asked to perform sitting/standing, stair ascent/descent, and level ground walking. The number of large-amplitude motion artifacts generated using each prototype was quantified, the amount of skin irritation documented, and the comfort level of each assembly subjectively assessed by the amputee subject. Of the four configurations tested, the combination of a suction socket with integrated wireless surface electrodes generated the lowest number of large-amplitude motion artifacts, the least visible skin irritation, and was judged to be most comfortable by the amputee subject. The collection of high-quality electromyographic signals from an amputee's residual limb while maximizing patient comfort holds substantial potential to enhance neuromuscular clinical assessment and as a method of intuitive control of powered lower-limb prostheses. © The International Society for Prosthetics and Orthotics 2014.
NASA Astrophysics Data System (ADS)
Ren, Yundong; Zhang, Rui; Ti, Chaoyang; Liu, Yuxiang
2016-09-01
Tapered optical fibers can deliver guided light into and carry light out of micro/nanoscale systems with low loss and high spatial resolution, which makes them ideal tools in integrated photonics and microfluidics. Special geometries of tapered fibers are desired for probing monolithic devices in plane as well as optical manipulation of micro particles in fluids. However, for many specially shaped tapered fibers, it remains a challenge to fabricate them in a straightforward, controllable, and repeatable way. In this work, we fabricated and characterized two special geometries of tapered optical fibers, namely fiber loops and helices, that could be switched between one and the other. The fiber loops in this work are distinct from previous ones in terms of their superior mechanical stability and high optical quality factors in air, thanks to a post-annealing process. We experimentally measured an intrinsic optical quality factor of 32,500 and a finesse of 137 from a fiber loop. A fiber helix was used to characterize a monolithic cavity optomechanical device. Moreover, a microfluidic "roller coaster" was demonstrated, where microscale particles in water were optically trapped and transported by a fiber helix. Tapered fiber loops and helices can find various applications ranging from on-the-fly characterization of integrated photonic devices to particle manipulation and sorting in microfluidics.
Guermandi, Marco; Bigucci, Alessandro; Franchi Scarselli, Eleonora; Guerrieri, Roberto
2015-01-01
We present a system for the acquisition of EEG signals based on active electrodes and implementing a Driving Right Leg circuit (DgRL). DgRL allows for single-ended amplification and analog-to-digital conversion, still guaranteeing a common mode rejection in excess of 110 dB. This allows the system to acquire high-quality EEG signals essentially removing network interference for both wet and dry-contact electrodes. The front-end amplification stage is integrated on the electrode, minimizing the system's sensitivity to electrode contact quality, cable movement and common mode interference. The A/D conversion stage can be either integrated in the remote back-end or placed on the head as well, allowing for an all-digital communication to the back-end. Noise integrated in the band from 0.5 to 100 Hz is comprised between 0.62 and 1.3 μV, depending on the configuration. Current consumption for the amplification and A/D conversion of one channel is 390 μA. Thanks to its low noise, the high level of interference suppression and its quick setup capabilities, the system is particularly suitable for use outside clinical environments, such as in home care, brain-computer interfaces or consumer-oriented applications.
Physician clinical alignment and integration: a community-academic hospital approach.
Salas-Lopez, Debbie; Weiss, Sandra Jarva; Nester, Brian; Whalen, Thomas
2014-01-01
An overwhelming need for change in the U.S. healthcare delivery system, coupled with the need to improve clinical and financial outcomes, has prompted hospitals to direct renewed efforts toward achieving high quality and cost-effectiveness. Additionally, with the dawn of accountable care organizations and increasing focus on patient expectations, hospitals have begun to seek physician partners through clinical alignment. Contrary to the unsuccessful alignment strategies of the 1990s, today's efforts are more mutually beneficial, driven by the need to achieve better care coordination, increased access to infrastructure, improved quality, and lower costs. In this article, we describe a large, academic, tertiary care hospital's approach to developing and implementing alignment and integration models with its collaboration-ready physicians and physician groups. We developed four models--short of physicians' employment with the organization--tailored to meet the needs of both the physician group and the hospital: (1) medical directorship (group physicians are appointed to serve as medical directors of a clinical area), (2) professional services agreement (specific clinical services, such as overnight admissions help, are contracted), (3) co-management services agreement (one specialty group co-manages all services within the specialty service lines), and (4) lease arrangement (closest in scope to employment, in which the hospital pays all expenses and receives all revenue). Successful hospital-physician alignment requires careful planning and the early engagement of legal counsel to ensure compliance with federal statutes. Establishing an integrated system with mutually identified goals better positions hospitals to deliver cost-effective and high-quality care under the new paradigm of healthcare reform.
Soil quality and the solar corridor crop system
USDA-ARS?s Scientific Manuscript database
The solar corridor crop system (SCCS) is designed for improved crop productivity based on highly efficient use of solar radiation by integrating row crops with drilled or solid-seeded crops in broad strips (corridors) that also facilitate establishment of cover crops for year-round soil cover. The S...
Soil Quality and the Solar Corridor Crop System
USDA-ARS?s Scientific Manuscript database
The solar corridor crop system (SCCS) is designed for improved crop productivity based on highly efficient use of solar radiation by integrating row crops with drilled or solid-seeded crops in broad strips (corridors) that also facilitate establishment of cover crops for year-round soil cover. The S...
Stakeholder participation is now widely viewed as an essential component of environmental management projects. Although scholarship has identified and conceptualized numerous elements and components of high-quality participation, we argue that the processes of recruiting stakehol...
ERIC Educational Resources Information Center
Nebbergall, Allison
2012-01-01
As technology increasingly transforms our daily lives, educators too are seeking strategies and resources that leverage technology to improve student learning. Research demonstrates that high-quality professional development, digital standards-based content, and personalized learning plans can increase student achievement, engagement, and…
Integrating the Science of Team Training: Guidelines for Continuing Education
ERIC Educational Resources Information Center
Weaver, Sallie J.; Rosen, Michael A.; Salas, Eduardo; Baum, Karyn D.; King, Heidi B.
2010-01-01
The provision of high-quality, efficient care results from the coordinated, cooperative efforts of multiple technically competent health care providers working in concert over time, spanning disciplinary and professional boundaries. Accordingly, the role of medical education must include the development of providers who are both expert clinicians…
78 FR 49760 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-15
... transparent method for identifying high-quality programs that can receive continuing five-year grants without... will employ a mixed-methods design that integrates and layers administrative and secondary data sources, observational measures, and interviews to develop a rich knowledge base about what the DRS accomplishes and how...
Healing and Building Soil on Prairie Birthday Farm
USDA-ARS?s Scientific Manuscript database
Native tallgrass prairie was restored as an integral part of a small, food-producing farm called Prairie Birthday Farm in Clay County, Missouri. Reconstruction of native prairie was essential to the farm’s goal of producing high quality food for the family, area residents and restaurant chefs. Impro...
USDA-ARS?s Scientific Manuscript database
Wetlands are an integral part of many agricultural watersheds. They provide multiple ecosystem functions, such as improving water quality, mitigating flooding, and serving as natural habitats. Those functions are highly depended on wetland hydrological characteristics and their connectivity to the d...
Comprehensive Behavioral Health and School Psychology: An Implementation Agenda
ERIC Educational Resources Information Center
Forman, Susan G.; Ward, Caryn S.; Fixsen, Dean L.
2017-01-01
The preceding articles provide important examples and guidance for the provision of high-quality behavioral health services for children and adolescents in schools. In this article, we discuss (a) the conceptual framework that underlies the need to develop comprehensive integrated care, (b) the foundational implementation issues that need to be…
We investigated the integrated ecosystem properties (gross production, respiration, and net ecosystem metabolism) in the Pensacola Bay estuary, using a combination of instrument deployments and plankton metabolism experiments. High-frequency water quality data were collected from...
Collaborative Wikipedia Projects in the Virtual Classroom
ERIC Educational Resources Information Center
Kenny, A. J.; Wolt, J. D.; Hurd, H. S.
2013-01-01
Wikipedia is a web-based, free-content encyclopedia that is openly editable and, thus, provides a unique platform for collaborations. Wikipedia projects are increasingly being integrated into upper-level courses across the country to explore advanced concepts, communicate science, and provide high-quality information to the public. Here we outline…
Various technological pathways can lead to reduced CO2 emissions. However, different pathways can have substantially different impacts on other environmental endpoints, such as air quality and energy-related water demand. The Global Change Assessment Model (GCAM) is a high resolu...
Integrated Social and Quality of Service Trust Management of Mobile Groups in Ad Hoc Networks
2013-01-01
high resiliency to malicious attacks and misbehaving nodes. Keywords—trust management; mobile ad hoc networks; QoS trust; social trust; trust...paper we address an importance issue of trust management protocol design for MANETs: trust bias minimization despite misbehaving nodes performing
NASA Technical Reports Server (NTRS)
Craig, Larry G.
2010-01-01
This slide presentation reviews three failures of software and how the failures contributed to or caused the failure of a launch or payload insertion into orbit. In order to avoid these systematic failures in the future, failure mitigation strategies are suggested for use.
Key elements of high-quality practice organisation in primary health care: a systematic review.
Crossland, Lisa; Janamian, Tina; Jackson, Claire L
2014-08-04
To identify elements that are integral to high-quality practice and determine considerations relating to high-quality practice organisation in primary care. A narrative systematic review of published and grey literature. Electronic databases (PubMed, CINAHL, the Cochrane Library, Embase, Emerald Insight, PsycInfo, the Primary Health Care Research and Information Service website, Google Scholar) were searched in November 2013 and used to identify articles published in English from 2002 to 2013. Reference lists of included articles were searched for relevant unpublished articles and reports. Data were configured at the study level to allow for the inclusion of findings from a broad range of study types. Ten elements were most often included in the existing organisational assessment tools. A further three elements were identified from an inductive thematic analysis of descriptive articles, and were noted as important considerations in effective quality improvement in primary care settings. Although there are some validated tools available to primary care that identify and build quality, most are single-strategy approaches developed outside health care settings. There are currently no validated organisational improvement tools, designed specifically for primary health care, which combine all elements of practice improvement and whose use does not require extensive external facilitation.
NASA Astrophysics Data System (ADS)
Blythe, Jessica Marie
The purpose of this study was to describe the influence of the train-the-trainer professional development form of professional development on participants' perceptions of agriscience integration and inquiry-based instruction (IBI). The independent variables considered were elements of high-quality professional development, such as duration, active participation, coherence, and school culture; teacher attitudes towards professional development; and teacher demographics. The dependent variables assessed were teachers' perceptions of agriscience integration and IBI. This study utilized a quasi-experimental design to assess the impacts of a teacher professional development program and experimental follow-up support on secondary teachers' perceptions of science integration and IBI. This study was a census of all teachers who attended a 2012 professional development workshop facilitated by a National Agriscience Teacher Ambassador at the FFA and/or NAAE National Convention. Participants completed four surveys over the subsequent year to assess their perceptions of agriscience integration and IBI. Descriptive methods were used to analyze teachers' perceptions of agriscience integration and IBI. Correlations and follow-up regression analysis were conducted to determine the relationships between the teachers' perceptions and the elements of high-quality teacher professional development. Results of the study revealed that respondents had favorable perceptions of science integration into agriculture programs and planned to increase the levels of science integration in their programs. Additionally, a majority of respondents reported utilizing IBI more than once a week. Because participants of the study did not utilize the experimental follow-up support system for the workshop, clear effects could not be determined. There was a positive correlation between science integration and IBI. A variation of positive and negative correlations was found between the dependent and independent variables. Five models were found to be significant predictors of respondents' perceptions of science integration three models were found to be significant predictors of IBI. These findings indicate that teachers perceive science integration and IBI as positive influences in secondary agriculture education which supports the integration of science and science teaching techniques in secondary agriculture education programs. Though relationships exist between science integration and IBI, and various elements of school culture and professional development, further investigation is needed to better understand these relationships and their predictive variability.
Integration of Design, Thermal, Structural, and Optical Analysis, Including Thermal Animation
NASA Technical Reports Server (NTRS)
Amundsen, Ruth M.
1993-01-01
In many industries there has recently been a concerted movement toward 'quality management' and the issue of how to accomplish work more efficiently. Part of this effort is focused on concurrent engineering; the idea of integrating the design and analysis processes so that they are not separate, sequential processes (often involving design rework due to analytical findings) but instead form an integrated system with smooth transfers of information. Presented herein are several specific examples of concurrent engineering methods being carried out at Langley Research Center (LaRC): integration of thermal, structural and optical analyses to predict changes in optical performance based on thermal and structural effects; integration of the CAD design process with thermal and structural analyses; and integration of analysis and presentation by animating the thermal response of a system as an active color map -- a highly effective visual indication of heat flow.
Integrated Quality Enhancement and Review of Higher Education in Further Education Colleges
ERIC Educational Resources Information Center
Davies, Philip; Simmons, Jonathan
2012-01-01
Integrated Quality Enhancement and Review (IQER) was introduced as quality assurance designed specifically for Higher Education (HE) in Further Education Colleges (FEC) in 2008. Following a historical account of the quality assurance systems applied to HE in FECs prior to this date, we analyse the first 64 IQER Summative Review reports produced…
Nanofabrication for On-Chip Optical Levitation, Atom-Trapping, and Superconducting Quantum Circuits
NASA Astrophysics Data System (ADS)
Norte, Richard Alexander
Researchers have spent decades refining and improving their methods for fabricating smaller, finer-tuned, higher-quality nanoscale optical elements with the goal of making more sensitive and accurate measurements of the world around them using optics. Quantum optics has been a well-established tool of choice in making these increasingly sensitive measurements which have repeatedly pushed the limits on the accuracy of measurement set forth by quantum mechanics. A recent development in quantum optics has been a creative integration of robust, high-quality, and well-established macroscopic experimental systems with highly-engineerable on-chip nanoscale oscillators fabricated in cleanrooms. However, merging large systems with nanoscale oscillators often require them to have extremely high aspect-ratios, which make them extremely delicate and difficult to fabricate with an experimentally reasonable repeatability, yield and high quality. In this work we give an overview of our research, which focused on microscopic oscillators which are coupled with macroscopic optical cavities towards the goal of cooling them to their motional ground state in room temperature environments. The quality factor of a mechanical resonator is an important figure of merit for various sensing applications and observing quantum behavior. We demonstrated a technique for pushing the quality factor of a micromechanical resonator beyond conventional material and fabrication limits by using an optical field to stiffen and trap a particular motional mode of a nanoscale oscillator. Optical forces increase the oscillation frequency by storing most of the mechanical energy in a nearly loss-less optical potential, thereby strongly diluting the effects of material dissipation. By placing a 130 nm thick SiO2 pendulum in an optical standing wave, we achieve an increase in the pendulum center-of-mass frequency from 6.2 to 145 kHz. The corresponding quality factor increases 50-fold from its intrinsic value to a final value of Qm = 5.8(1.1) x 105, representing more than an order of magnitude improvement over the conventional limits of SiO2 for a pendulum geometry. Our technique may enable new opportunities for mechanical sensing and facilitate observations of quantum behavior in this class of mechanical systems. We then give a detailed overview of the techniques used to produce high-aspect-ratio nanostructures with applications in a wide range of quantum optics experiments. The ability to fabricate such nanodevices with high precision opens the door to a vast array of experiments which integrate macroscopic optical setups with lithographically engineered nanodevices. Coupled with atom-trapping experiments in the Kimble Lab, we use these techniques to realize a new waveguide chip designed to address ultra-cold atoms along lithographically patterned nanobeams which have large atom-photon coupling and near 4pi Steradian optical access for cooling and trapping atoms. We describe a fully integrated and scalable design where cold atoms are spatially overlapped with the nanostring cavities in order to observe a resonant optical depth of d0 ≈ 0.15. The nanodevice illuminates new possibilities for integrating atoms into photonic circuits and engineering quantum states of atoms and light on a microscopic scale. We then describe our work with superconducting microwave resonators coupled to a phononic cavity towards the goal of building an integrated device for quantum-limited microwave-to-optical wavelength conversion. We give an overview of our characterizations of several types of substrates for fabricating a low-loss high-frequency electromechanical system. We describe our electromechanical system fabricated on a SiN membrane which consists of a 12 GHz superconducting LC resonator coupled capacitively to the high frequency localized modes of a phononic nanobeam. Using our suspended membrane geometry we isolate our system from substrates with significant loss tangents, drastically reducing the parasitic capacitance of our superconducting circuit to ≈ 2.5 fF. This opens up a number of possibilities in making a new class of low-loss high-frequency electromechanics with relatively large electromechanical coupling. We present our substrate studies, fabrication methods, and device characterization.
Integrated indicators are important metrics of catchment biogeochemical function
NASA Astrophysics Data System (ADS)
Howden, N. J. K.; Birgand, F.; Burt, T.; Worrall, F.
2017-12-01
There are many ways to characterise catchment biogeochemical behaviour, but most rely on sporadic measurements that capture transient, rather than steady-state behaviour and function. This is because the ongoing collection of water samples and flow data can be labour intensive and thus costly both in terms of money and time. We propose that key aspects of catchment biogeochemical function can only be determined by the collation of impacts of water quality and flow integrated over time. In this paper we will illustrate how spot sample data may be useful, but also how the integration of sample data over time begins to elucidate catchment functions that may not be apparent from sparse timeslices of information. We use a number of high-resolution time series of water quality and flow data to illustrate the utility of this approach for different determinands and suggest key priorities for both sampling and analysis in small to medium-sized catchments. Clearly it is impractical for high-frequency measurements to form the basis of a wide-ranging approach, due to the prevalence of infrequent sampling as a regulatory preference across much of the world. In order to make our results relevant to this wider perspective, we also consider how infrequent sampling regimes may be used to derive our preferred integrated metrics, and the uncertainties that will be propagated due to the lower timescales of sampling. We use data from Brittany (France), North Carolina (US) and Plynlimmon (UK) to consider how our results translate to different catchments.
Hack, Carolin C; Hackl, Janina; Hüttner, Nina B M; Langemann, Hanna; Schwitulla, Judith; Dietzel-Drentwett, Svenja; Fasching, Peter A; Beckmann, Matthias W; Theuser, Anna-Katharin
2018-05-01
Although the demand from patients for integrative medicine is increasing, complementary medicine services are still quite heterogeneous and have not been incorporated into clinical routine. The aim of this study was to systematically evaluate improvements in side effects and quality of life associated with a hospital-based integrative medicine program in the modern breast cancer patient care setting. In a cross-sectional study, integrative health counseling and treatment were evaluated in women with breast cancer. Over a 15-month period, data for 75 patients from an integrative medicine consultancy service with standardized operating procedures were collected at the University Breast Center for Franconia. At baseline, the patients answered a questionnaire on their medical history, symptoms, and the treatment goals they were hoping to achieve with integrative medicine. In the follow-up, patient-reported outcomes related to side effects of conventional cancer treatment and patients' quality of life were analyzed. Among 60 patients with the therapy goal of reducing the side effects of conventional treatment, 46 (76.7%) were successful. Among 57 patients hoping to improve disease-related quality of life, 46 (82%) reported success. Whereas patients with metastatic disease achieved a reduction in the side effects of conventional therapy, quality-of-life improvements were predominantly achieved by patients with a good treatment prognosis. Breast cancer patients benefit from the counseling and treatment provided with integrative medicine in all phases of tumor disease. Integrative treatment services should be included as part of patient care in clinical routine work to offer patients the maximum quality of care and safety with complementary therapies.
Yerramilli, Anjaneyulu; Dodla, Venkata B; Desamsetti, Srinivas; Challa, Srinivas V; Young, John H; Patrick, Chuck; Baham, Julius M; Hughes, Robert L; Yerramilli, Sudha; Tuluri, Francis; Hardy, Mark G; Swanier, Shelton J
2011-06-01
In this study, an attempt was made to simulate the air quality with reference to ozone over the Jackson (Mississippi) region using an online WRF/Chem (Weather Research and Forecasting-Chemistry) model. The WRF/Chem model has the advantages of the integration of the meteorological and chemistry modules with the same computational grid and same physical parameterizations and includes the feedback between the atmospheric chemistry and physical processes. The model was designed to have three nested domains with the inner-most domain covering the study region with a resolution of 1 km. The model was integrated for 48 hours continuously starting from 0000 UTC of 6 June 2006 and the evolution of surface ozone and other precursor pollutants were analyzed. The model simulated atmospheric flow fields and distributions of NO2 and O3 were evaluated for each of the three different time periods. The GIS based spatial distribution maps for ozone, its precursors NO, NO2, CO and HONO and the back trajectories indicate that all the mobile sources in Jackson, Ridgeland and Madison contributing significantly for their formation. The present study demonstrates the applicability of WRF/Chem model to generate quantitative information at high spatial and temporal resolution for the development of decision support systems for air quality regulatory agencies and health administrators.
NASA Astrophysics Data System (ADS)
Wang, Xiao; Zhang, Tian-Bao; Yang, Wen; Zhu, Hao; Chen, Lin; Sun, Qing-Qing; Zhang, David Wei
2017-01-01
The effective and high-quality integration of high-k dielectrics on two-dimensional (2D) crystals is essential to the device structure engineering and performance improvement of field-effect transistor (FET) based on the 2D semiconductors. We report a 2D MoS2 transistor with ultra-thin Al2O3 top-gate dielectric (6.1 nm) and extremely low leakage current. Remote forming gas plasma pretreatment was carried out prior to the atomic layer deposition, providing nucleation sites with the physically adsorbed ions on the MoS2 surface. The top gate MoS2 FET exhibited excellent electrical performance, including high on/off current ratio over 109, subthreshold swing of 85 mV/decade and field-effect mobility of 45.03 cm2/V s. Top gate leakage current less than 0.08 pA/μm2 at 4 MV/cm has been obtained, which is the smallest compared with the reported top-gated MoS2 transistors. Such an optimized integration of high-k dielectric in 2D semiconductor FET with enhanced performance is very attractive, and it paves the way towards the realization of more advanced 2D nanoelectronic devices and integrated circuits.
Ernst, E J; Speck, Patricia M; Fitzpatrick, Joyce J
2011-12-01
With the patient's consent, physical injuries sustained in a sexual assault are evaluated and treated by the sexual assault nurse examiner (SANE) and documented on preprinted traumagrams and with photographs. Digital imaging is now available to the SANE for documentation of sexual assault injuries, but studies of the image quality of forensic digital imaging of female genital injuries after sexual assault were not found in the literature. The Photo Documentation Image Quality Scoring System (PDIQSS) was developed to rate the image quality of digital photo documentation of female genital injuries after sexual assault. Three expert observers performed evaluations on 30 separate images at two points in time. An image quality score, the sum of eight integral technical and anatomical attributes on the PDIQSS, was obtained for each image. Individual image quality ratings, defined by rating image quality for each of the data, were also determined. The results demonstrated a high level of image quality and agreement when measured in all dimensions. For the SANE in clinical practice, the results of this study indicate that a high degree of agreement exists between expert observers when using the PDIQSS to rate image quality of individual digital photographs of female genital injuries after sexual assault. © 2011 International Association of Forensic Nurses.
Higgins, Martin; Chen, Eric Zhong; Gebbie, Ailsa E; Fernando, Imali; Milne, Dona; Cochrane, Rosemary
2014-10-01
UK policy documents advocate integrated approaches to sexual health service provision to ensure that everyone can access high-quality treatment. However, there is relatively little evidence to demonstrate any resultant benefits. The family planning and genitourinary medicine services in Lothian have been fully integrated and most care is now delivered from a purpose-built sexual health centre. We wished to study the views of staff on integrated sexual and reproductive care. Staff completed anonymous questionnaires before and after integration, looking at four main aspects: the patient pathway, specific patient groups, their own professional status, and their working environment. The surveys used a mixture of five-point Likert-type scales and open-ended questions. Over 50% of staff completed the surveys on each occasion. Six months after the new building opened, staff attitudes about the integrated service were mixed. Staff reported more stress and less opportunity for specialisation but there was no change in their sense of professional status or development. There were concerns about how well the integrated service met the needs of specific patient groups, notably women. These concerns co-existed with a verdict that overall service quality was no worse following integration. Staff views should form an important part of service redesign and integration projects. Although the results from the Lothian surveys suggest a perceived worsening of some aspects of the service, further evaluation is needed to unpick the different problems that have appeared under the catch-all term of 'integration'. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Argo workstation: a key component of operational oceanography
NASA Astrophysics Data System (ADS)
Dong, Mingmei; Xu, Shanshan; Miao, Qingsheng; Yue, Xinyang; Lu, Jiawei; Yang, Yang
2018-02-01
Operational oceanography requires the quantity, quality, and availability of data set and the timeliness and effectiveness of data products. Without steady and strong operational system supporting, operational oceanography will never be proceeded far. In this paper we describe an integrated platform named Argo Workstation. It operates as a data processing and management system, capable of data collection, automatic data quality control, visualized data check, statistical data search and data service. After it is set up, Argo workstation provides global high quality Argo data to users every day timely and effectively. It has not only played a key role in operational oceanography but also set up an example for operational system.
An investigation for the development of an integrated optical data preprocessor
NASA Technical Reports Server (NTRS)
Verber, C. M.; Vahey, D. W.; Kenan, R. P.; Wood, V. E.; Hartman, N. F.; Chapman, C. M.
1978-01-01
The successful fabrication and demonstration of an integrated optical circuit designed to perform a parallel processing operation by utilizing holographic subtraction to simultaneously compare N analog signal voltages with N predetermined reference voltages is summarized. The device alleviates transmission, storage and processing loads of satellite data systems by performing, at the sensor site, some preprocessing of data taken by remote sensors. Major accomplishments in the fabrication of integrated optics components include: (1) fabrication of the first LiNbO3 waveguide geodesic lens; (2) development of techniques for polishing TIR mirrors on LiNbO3 waveguides; (3) fabrication of high efficiency metal-over-photoresist gratings for waveguide beam splitters; (4) demonstration of high S/N holographic subtraction using waveguide holograms; and (5) development of alignment techniques for fabrication of integrated optics circuits. Important developments made in integrated optics are the discovery and suggested use of holographic self-subtraction in LiNbO3, development of a mathematical description of the operating modes of the preprocessor, and the development of theories for diffraction efficiency and beam quality of two dimensional beam defined gratings.
Lorenzetti, Lara M J; Leatherman, Sheila; Flax, Valerie L
2017-06-01
Solutions delivered within firm sectoral boundaries are inadequate in achieving income security and better health for poor populations. Integrated microfinance and health interventions leverage networks of women to promote financial inclusion, build livelihoods, and safeguard against high cost illnesses. Our understanding of the effect of integrated interventions has been limited by variability in intervention, outcome, design, and methodological rigour. This systematic review synthesises the literature through 2015 to understand the effect of integrated microfinance and health programs. We searched PubMed, Scopus, Embase, EconLit, and Global Health databases and sourced bibliographies, identifying 964 articles exclusive of duplicates. Title, abstract, and full text review yielded 35 articles. Articles evaluated the effect of intentionally integrated microfinance and health programs on client outcomes. We rated the quality of evidence for each article. Most interventions combined microfinance with health education, which demonstrated positive effects on health knowledge and behaviours, though not health status. Among programs that integrated microfinance with other health components ( i.e. health micro-insurance, linkages to health providers, and access to health products), results were generally positive but mixed due to the smaller number and quality of studies. Interventions combining multiple health components in a given study demonstrated positive effects, though it was unclear which component was driving the effect. Most articles (57%) were moderate in quality. Integrated microfinance and health education programs were effective, though longer intervention periods are necessary to measure more complex pathways to health status. The effect of microfinance combined with other health components was less clear. Stronger randomized research designs with multiple study arms are required to improve evidence and disentangle the effects of multiple component microfinance and health interventions. Few studies attempted to understand changes in economic outcomes, limiting our understanding of the relationship between health and income effects. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Forsgren, Eva; Locke, Barbara; Semberg, Emilia; Laugen, Ane T; Miranda, Joachim R de
2017-08-01
Viral infections in managed honey bees are numerous, and most of them are caused by viruses with an RNA genome. Since RNA degrades rapidly, appropriate sample management and RNA extraction methods are imperative to get high quality RNA for downstream assays. This study evaluated the effect of various sampling-transport scenarios (combinations of temperature, RNA stabilizers, and duration) of transport on six RNA quality parameters; yield, purity, integrity, cDNA synthesis efficiency, target detection and quantification. The use of water and extraction buffer were also compared for a primary bee tissue homogenate prior to RNA extraction. The strategy least affected by time was preservation of samples at -80°C. All other regimens turned out to be poor alternatives unless the samples were frozen or processed within 24h. Chemical stabilizers have the greatest impact on RNA quality and adding an extra homogenization step (a QIAshredder™ homogenizer) to the extraction protocol significantly improves the RNA yield and chemical purity. This study confirms that RIN values (RNA Integrity Number), should be used cautiously with bee RNA. Using water for the primary homogenate has no negative effect on RNA quality as long as this step is no longer than 15min. Copyright © 2017 Elsevier B.V. All rights reserved.
Losano, João D A; Angrimani, Daniel S R; Dalmazzo, Andressa; Rocha, Carolina C; Brito, Maíra M; Perez, Eduardo G A; Tsunoda, Roberta H; Góes, Paola A A; Mendes, Camilla M; Assumpção, Mayra E O A; Barnabe, Valquiria H; Nichi, Marcilio
2018-04-03
Taurine bulls are highly susceptible to heat stress, leading to increased oxidative stress (OS) and impaired sperm viability. Polyunsaturated fatty acids (PUFAs) supplementation can be an alternative to improve semen quality, which also results in more sperm susceptibility to lipid peroxidation. Moreover, this deleterious effect can be exacerbated in animals affected by heat stress. Vitamin E is a key antioxidant that counteracts lipid peroxidation of sperm membrane caused by OS. Thus, combining PUFAs with vitamin E may improve sperm quality. In this context, this study aimed to evaluate the effect of interaction between PUFAs and vitamin E on sperm quality in Bos taurus bulls under testicular heat stress. Sixteen taurine bulls under testicular heat stress were randomly assigned in four groups: Control, Vitamin E, PUFA, and PUFA + Vitamin E. All groups lasted for 60 days. Samples were cryopreserved/thawed and analyzed for motility variables (CASA), membrane and acrosome integrity, mitochondrial activity, susceptibility to oxidative stress, DNA integrity, and sperm-binding capacity. Results showed that vitamin E had a beneficial effect on some sperm characteristics, whereas PUFA supplementation had an adverse effect when the two treatments were evaluated separately. Finally, the association between PUFAs and vitamin E did not improve sperm quality.
Hwang, Hyun-Min; Carr, Robert S.; Cherr, Gary N.; Green, Peter G.; Grosholz, Edwin G.; Judah, Linda; Morgan, Steven G.; Ogle, Scott; Rashbrook, Vanessa K.; Rose, Wendy L.; Teh, Swee J.; Vines, Carol A.; Anderson, Susan L.
2013-01-01
The objective of this study was to evaluate the efficacy of integrating a traditional sediment quality triad approach with selected sublethal chronic indicators in resident species in assessing sediment quality in four salt marshes in northern California, USA. These included the highly contaminated (Stege Marsh) and relatively clean (China Camp) marshes in San Francisco Bay and two reference marshes in Tomales Bay. Toxicity potential of contaminants and benthic macroinvertebrate survey showed significant differences between contaminated and reference marshes. Sublethal responses (e.g., apoptotic DNA fragmentation, lipid accumulation, and glycogen depletion) in livers of longjaw mudsucker (Gillichthys mirabilis) and embryo abnormality in lined shore crab (Pachygrapsus crassipes) also clearly distinguished contaminated and reference marshes, while other responses (e.g., cytochrome P450, metallothionein) did not. This study demonstrates that additional chronic sublethal responses in resident species under field exposure conditions can be readily combined with sediment quality triads for an expanded multiple lines of evidence approach. This confirmatory step may be warranted in environments like salt marshes in which natural variables may affect interpretation of toxicity test data. Qualitative and quantitative integration of the portfolio of responses in resident species and traditional approach can support a more comprehensive and informative sediment quality assessment in salt marshes and possibly other habitat types as well.
Evaluation of the Quality of Online Information for Patients with Rare Cancers: Thyroid Cancer.
Kuenzel, Ulrike; Monga Sindeu, Tabea; Schroth, Sarah; Huebner, Jutta; Herth, Natalie
2017-01-24
The Internet offers an easy and quick access to a vast amount of patient information. However, several studies point to the poor quality of many websites and the resulting hazards of false information. The aim of this study was to assess quality of information on thyroid cancer. A patients' search for information about thyroid cancer on German websites was simulated using the search engine Google and the patient portal "Patienten-Information.de". The websites were assessed using a standardized instrument with formal and content aspects from the German Cancer Society. Supporting the results of prior studies that analysed patient information on the Internet, the data showed that the quality of patient information on thyroid cancer is highly heterogeneous depending on the website providers. The majority of website providers are represented by media and health providers other than health insurances, practices and professionals offering patient information of relatively poor quality. Moreover, most websites offer patient information of low-quality content. Only a few trustworthy, high-quality websites exist. Especially Google, a common search engine, focuses more on the dissemination of information than on quality aspects. In order to improve the patient information from the Internet, the visibility of high-quality websites must be improved. For that, education programs to improve patients' eHealth literacy are needed. A quick and easy evaluation tool for online information suited for patients should be implemented, and patients should be taught to integrate such a tool into their research process.
NASA Astrophysics Data System (ADS)
Li, Yang; Yao, Zhao; Fu, Xiao-Qian; Li, Zhi-Ming; Shan, Fu-Kai; Wang, Cong
2017-05-01
Recently, integrated passive devices have become increasingly popular; inductor realization, in particular, offers interesting high performance for RF modules and systems. In this paper, a development of differential inductor fabricated by integrated passive devices technology using a double air-bridge structure is presented. A study of the model development of the differential inductor is first demonstrated. In this model section, a segment box analysis method is applied to provide a clear presentation of the differential inductor. Compared with other work that only shows a brief description of the process, the integrated passive devices process used to fabricate the inductor in this study is elaborated on. Finally, a characterization of differential inductors with different physical layout parameters is illustrated based on inductance and quality factors, which provides a valuable reference for realizing high performance. The proposed work provides a good solution for the design, fabrication and practical application of RF modules and systems.
NASA Astrophysics Data System (ADS)
Mader, Julien; Rubio, Anna; Asensio Igoa, Jose Luis; Corgnati, Lorenzo; Mantovani, Carlo; Griffa, Annalisa; Gorringe, Patrick; Alba, Marco; Novellino, Antonio
2017-04-01
High Frequency radar (HFR) is a land-based remote sensing instrument offering a unique insight to coastal ocean variability, by providing synoptic, high frequency and high resolution data at the ocean atmosphere interface. HFRs have become invaluable tools in the field of operational oceanography for measuring surface currents, waves and winds, with direct applications in different sectors and an unprecedented potential for the integrated management of the coastal zone. To further the use of HFRs into the Copernicus Marine environment monitoring service, CMEMS, is becoming crucial to ensure the improved management of several related key issues such as Marine Safety, Marine Resources, Coastal & Marine Environment, Weather, Climate & Seasonal Forecast. In this context, INCREASE (Innovation and Networking for the integration of Coastal Radars into European mArine SErvices) project aims to set the necessary developments towards the integration of the existing European HFR operational systems into the CMEMS, following five main objectives: (i) Define and implement a common data and metadata model for HFR real-time data; (ii) Provide HFR quality controlled real-time surface currents and key derived products; (iii) Set the basis for the management of historical data and methodologies for advanced delayed mode quality-control techniques; (iv) Advance the use of HFR data for improving CMEMS numerical modelling systems; and (v) Enable an HFR European operational node to ensure the link with operational CMEMS. In cooperation with other ongoing initiatives (like the EuroGOOS HFR Task Team and the European project JERICO_NEXT), INCREASE has already set up the data management infrastructure to manage and make discoverable and accessible near real time data from 30 systems in Europe. This paper presents the achieved results and available products and features.
NASA Astrophysics Data System (ADS)
Long, James M., III
1995-10-01
The capacity to access, integrate, and analyze demographic, financial, and clinical data within a regional health care system represents an opportunity to ensure and enhance clinical quality and to reduce costs in a carefully planned and controlled manner. Properly used, such capability should improve health care delivery for local populations and provide the institution with a level of integration of services achieved by few health care organizations. The Baptist Health System (BHS), based in Birmingham, Alabama, is currently standardizing operating procedures among its various components and implementing a comprehensive, enterprise-wide information network. Clinical quality improvement and case management are being promulgated throughout the enterprise using a continuum-of-care model developed internally. Having successfully completed a pilot project using teleconferences for core lectures in internal medicine between two large teaching hospitals, BHS is taking advantage of enterprise- wide teleconference capability using a combination of fiberoptic (T3) and standard digital telephone (T1) transmission to speed installation and reduce the cost of implementation into two office buildings and eleven hospitals. The information system will serve to prepare BHS for the advent of managed care and other anticipated changes in health care, while ensuring continued ability to deliver high quality, cost-effective medical and health-related services.
NASA Astrophysics Data System (ADS)
Priebe, Elizabeth H.; Neville, C. J.; Rudolph, D. L.
2018-03-01
The spatial coverage of hydraulic conductivity ( K) values for large-scale groundwater investigations is often poor because of the high costs associated with hydraulic testing and the large areas under investigation. Domestic water wells are ubiquitous and their well logs represent an untapped resource of information that includes mandatory specific-capacity tests, from which K can be estimated. These specific-capacity tests are routinely conducted at such low pumping rates that well losses are normally insignificant. In this study, a simple and practical approach to augmenting high-quality K values with reconnaissance-level K values from water-well specific-capacity tests is assessed. The integration of lesser quality K values from specific-capacity tests with a high-quality K data set is assessed through comparisons at two different scales: study-area-wide (a 600-km2 area in Ontario, Canada) and in a single geological formation within a portion of the broader study area (200 km2). Results of the comparisons demonstrate that reconnaissance-level K estimates from specific-capacity tests approximate the ranges and distributions of the high-quality K values. Sufficient detail about the physical basis and assumptions that are invoked in the development of the approach are presented here so that it can be applied with confidence by practitioners seeking to enhance their spatial coverage of K values with specific-capacity tests.
Integrated Metamaterials and Nanophotonics in CMOS-Compatible Materials
NASA Astrophysics Data System (ADS)
Reshef, Orad
This thesis explores scalable nanophotonic devices in integrated, CMOS-compatible platforms. Our investigation focuses on two main projects: studying the material properties of integrated titanium dioxide (TiO2), and studying integrated metamaterials in silicon-on-insulator (SOI) technologies. We first describe the nanofabrication process for TiO2 photonic integrated circuits. We use this procedure to demonstrate polycrystalline anatase TiO2 ring resonators with high quality factors. We measure the thermo-optic coefficient of TiO2 and determine that it is negative, a unique property among CMOS-compatible dielectric photonic platforms. We also derive a transfer function for ring resonators in the presence of reflections and demonstrate using full-wave simulations that these reflections produce asymmetries in the resonances. For the second half of the dissertation, we design and demonstrate an SOI-based photonic-Dirac-cone metamaterial. Using a prism composed of this metamaterial, we measure its index of refraction and unambiguously determine that it is zero. Next, we take a single channel of this metamaterial to form a waveguide. Using interferometry, we independently confirm that the waveguide in this configuration preserves the dispersion profile of the aggregate medium, with a zero phase advance. We also characterize the waveguide, determining its propagation loss. Finally, we perform simulations to study nonlinear optical phenomena in zero-index media. We find that an isotropic refractive index near zero relaxes certain phase-matching constraints, allowing for more flexible configurations of nonlinear devices with dramatically reduced footprints. The outcomes of this work enable higher quality fabrication of scalable nanophotonic devices for use in nonlinear applications with passive temperature compensation. These devices are CMOS-compatible and can be integrated vertically for compact, device-dense industrial applications. It also provides access to a versatile, scalable and integrated medium with a refractive index that can be continuously engineered between n = -0.20 and n = +0.50. This opens the door to applications in high-precision interferometry, sensing, quantum information technologies and compact nonlinear applications.
Dedicated education unit: student perspectives.
Nishioka, Vicki M; Coe, Michael T; Hanita, Makoto; Moscato, Susan R
2014-01-01
The study compared students' perceptions of their clinical learning experiences in a dedicated education unit (DEU) with their experiences in traditional clinical education. Unlike traditional academic-instructor models, expert nurses in the DEU provide clinical education to students with faculty support. This repeated measures design used student surveys, supplemented by focus group data. Students were more likely to agree that their clinical learning experience was high quality and they had a consistent mentoring relationship during DEU rotations. Students also reported the quality of the unit's learning environment, the leadership style of the nurse manager, and the nursing care on the unit was more favorable in DEUs than traditional units. Consistent with their changed role in DEUs, faculty members were less active in helping students integrate theory and practice. These findings provide additional evidence of the value that the DEU model contributes to high-quality clinical education.
DOE Office of Scientific and Technical Information (OSTI.GOV)
KNUPP,PATRICK; MITCHELL,SCOTT A.
1999-11-01
In an attempt to automatically produce high-quality all-hex meshes, we investigated a mesh improvement strategy: given an initial poor-quality all-hex mesh, we iteratively changed the element connectivity, adding and deleting elements and nodes, and optimized the node positions. We found a set of hex reconnection primitives. We improved the optimization algorithms so they can untangle a negative-Jacobian mesh, even considering Jacobians on the boundary, and subsequently optimize the condition number of elements in an untangled mesh. However, even after applying both the primitives and optimization we were unable to produce high-quality meshes in certain regions. Our experiences suggest that manymore » boundary configurations of quadrilaterals admit no hexahedral mesh with positive Jacobians, although we have no proof of this.« less
Characterizations of a quality certified athletic trainer.
Raab, Scot; Wolfe, Brent D; Gould, Trenton E; Piland, Scott G
2011-01-01
Didactic proficiency does not ensure clinical aptitude. Quality athletic health care requires clinical knowledge and affective traits. To develop a grounded theory explaining the constructs of a quality certified athletic trainer (AT). Delphi study. Interviews in conference rooms or business offices and by telephone. Thirteen ATs (men = 8, women = 5) stratified across the largest employment settings (high school, college, clinical) in the 4 largest districts of the National Athletic Trainers? Association (2, 3, 4, 9). Open-ended interview questions were audio recorded, transcribed, and reviewed before condensing. Two member checks ensured trustworthiness. Open coding reduced text to descriptive adjectives. We grouped adjectives into 5 constructs (care, communication, commitment, integrity, knowledge) and grouped these constructs into 2 higher-order constructs (affective traits, effective traits). According to participants, ATs who demonstrate the ability to care, show commitment and integrity, value professional knowledge, and communicate effectively with others can be identified as quality ATs. These abilities facilitate the creation of positive relationships. These relationships allow the quality AT to interact with patients and other health care professionals on a knowledgeable basis that ultimately improves health care delivery. Our resulting theory supported the examination of characteristics not traditionally assessed in an athletic training education program. If researchers can show that these characteristics develop ATs into quality ATs (eg, those who work better with others, relate meaningfully with patients, and improve the standard of health care), they must be cultivated in the educational setting.
Appleton, P L; Quyn, A J; Swift, S; Näthke, I
2009-05-01
Visualizing overall tissue architecture in three dimensions is fundamental for validating and integrating biochemical, cell biological and visual data from less complex systems such as cultured cells. Here, we describe a method to generate high-resolution three-dimensional image data of intact mouse gut tissue. Regions of highest interest lie between 50 and 200 mum within this tissue. The quality and usefulness of three-dimensional image data of tissue with such depth is limited owing to problems associated with scattered light, photobleaching and spherical aberration. Furthermore, the highest-quality oil-immersion lenses are designed to work at a maximum distance of =10-15 mum into the sample, further compounding the ability to image at high-resolution deep within tissue. We show that manipulating the refractive index of the mounting media and decreasing sample opacity greatly improves image quality such that the limiting factor for a standard, inverted multi-photon microscope is determined by the working distance of the objective as opposed to detectable fluorescence. This method negates the need for mechanical sectioning of tissue and enables the routine generation of high-quality, quantitative image data that can significantly advance our understanding of tissue architecture and physiology.
NASA Astrophysics Data System (ADS)
Velicu, S.; Bommena, R.; Morley, M.; Zhao, J.; Fahey, S.; Cowan, V.; Morath, C.
2013-09-01
The development of a broadband IR focal plane array poses several challenges in the area of detector design, material, device physics, fabrication process, hybridization, integration and testing. The purpose of our research is to address these challenges and demonstrate a high-performance IR system that incorporates a HgCdTe-based detector array with high uniformity and operability. Our detector architecture, grown using molecular beam epitaxy (MBE), is vertically integrated, leading to a stacked detector structure with the capability to simultaneously detect in two spectral bands. MBE is the method of choice for multiplelayer HgCdTe growth because it produces material of excellent quality and allows composition and doping control at the atomic level. Such quality and control is necessary for the fabrication of multicolor detectors since they require advanced bandgap engineering techniques. The proposed technology, based on the bandgap-tunable HgCdTe alloy, has the potential to extend the broadband detector operation towards room temperature. We present here our modeling, MBE growth and device characterization results, demonstrating Auger suppression in the LWIR band and diffusion limited behavior in the MWIR band.
2009-01-01
Background The individual and societal burden of hand eczema is high. Literature indicates that moderate to severe hand eczema is a disease with a poor prognosis. Many patients are hampered in their daily activities, including work. High costs are related to high medical consumption, productivity loss and sick leave. Usual care is suboptimal, due to a lack of optimal instruction and coordination of care, and communication with the general practitioner/occupational physician and people involved at the workplace. Therefore, an integrated, multidisciplinary intervention involving a dermatologist, a care manager, a specialized nurse and a clinical occupational physician was developed. This paper describes the design of a study to investigate the effectiveness and cost-effectiveness of integrated care for hand eczema by a multidisciplinary team, coordinated by a care manager, consisting of instruction on avoiding relevant contact factors, both in the occupational and in the private environment, optimal skin care and treatment, compared to usual, dermatologist-led care. Methods The study is a multicentre, randomized, controlled trial with an economic evaluation alongside. The study population consists of patients with chronic, moderate to severe hand eczema, who visit an outpatient clinic of one of the participating 5 (three university and two general) hospitals. Integrated, multidisciplinary care, coordinated by a care manager, including allergo-dermatological evaluation by a dermatologist, occupational intervention by a clinical occupational physician, and counselling by a specialized nurse on optimizing topical treatment and skin care will be compared with usual care by a dermatologist. The primary outcome measure is the cumulative difference in reduction of the clinical severity score HECSI between the groups. Secondary outcome measures are the patient's global assessment, specific quality of life with regard to the hands, generic quality of life, sick leave and patient satisfaction. An economic evaluation will be conducted alongside the RCT. Direct and indirect costs will be measured. Outcome measures will be assessed at baseline and after 4, 12, 26 and 52 weeks. All statistical analyses will be performed on the intention-to-treat principle. In addition, per protocol analyses will be carried out. Discussion To improve societal participation of patients with moderate to severe hand eczema, an integrated care intervention was developed involving both person-related and environmental factors. Such integrated care is expected to improve the patients' clinical signs, quality of life and to reduce sick leave and medical costs. Results will become available in 2011. PMID:19951404
Miller, James S; English, Lacey; Matte, Michael; Mbusa, Rapheal; Ntaro, Moses; Bwambale, Shem; Kenney, Jessica; Siedner, Mark J; Reyes, Raquel; Lee, Patrick T; Mulogo, Edgar; Stone, Geren S
2018-02-27
Village health workers (VHWs) in five villages in Bugoye subcounty (Kasese District, Uganda) provide integrated community case management (iCCM) services, in which VHWs evaluate and treat malaria, pneumonia, and diarrhoea in children under 5 years of age. VHWs use a "Sick Child Job Aid" that guides them through the evaluation and treatment of these illnesses. A retrospective observational study was conducted to measure the quality of iCCM care provided by 23 VHWs in 5 villages in Bugoye subcounty over a 2-year period. Patient characteristics and clinical services were summarized using existing aggregate programme data. Lot quality assurance sampling of individual patient records was used to estimate adherence to the iCCM algorithm, VHW-level quality (based on adherence to the iCCM protocol), and change over time in quality of care (using generalized estimating equations regression modelling). For each of 23 VHWs, 25 patient visits were randomly selected from a 2-year period after iCCM care initiation. In these visits, 97% (150) of patients with diarrhoea were treated with oral rehydration and zinc, 95% (216) of patients with pneumonia were treated with amoxicillin, and 94% (240) of patients with malaria were treated with artemisinin-based combination therapy or rectal artesunate. However, only 44% (44) of patients with a negative rapid test for malaria were appropriately referred to a health facility. Overall, 75% (434) of patients received all the correct evaluation and management steps. Only 9 (39%) of the 23 VHWs met the pre-determined LQAS threshold for high-quality care over the 2-year observation period. Quality of care increased significantly in the first 6 months after initiation of iCCM services (p = 0.003), and then plateaued during months 7-24. Quality of care was high for uncomplicated malaria, pneumonia and diarrhoea. Overall quality of care was lower, in part because VHWs often did not follow the guidelines to refer patients with fever who tested negative for malaria. Quality of care appears to improve in the initial months after iCCM implementation, as VHWs gain initial experience in iCCM care.
A novel polishing technology for epoxy resin based on 355 nm UV laser
NASA Astrophysics Data System (ADS)
Meng, Xinling; Tao, Luqi; Liu, Zhaolin; Yang, Yi; Ren, Tianling
2017-06-01
The electromagnetic shielding film has drawn much attention due to its wide applications in the integrated circuit package, which demands a high surface quality of epoxy resin. However, gaseous Cu will splash and adhere to epoxy resin surface when the Cu layer in PCB receives enough energy in the process of laser cutting, which has a negative effect on the quality of the shielding film. Laser polishing technology can solve this problem and it can effectively improve the quality of epoxy resin surface. The paper studies the mechanism of Cu powder spraying on the compound surface by 355 nm ultraviolet (UV) laser, including the parameters of laser polishing process and the remains of Cu content on compound surface. The results show that minimal Cu content can be realized with a scanning speed of 700 mm/s, a laser frequency of 50 kHz and the distance between laser focus and product top surface of -1.3 mm. This result is important to obtain an epoxy resin surface with high quality. Project supported by the National Natural Science Foundation of China (Nos. 61574083, 61434001), the National Basic Research Program (No. 2015CB352100), the National Key Project of Science and Technology (No. 2011ZX02403-002), the Special Fund for Agroscientic Research in the Public Interest of China (No 201303107), the support of the Independent Research Program of Tsinghua University (No. 2014Z01006), and Advanced Sensor and Integrated System Lab of Tsinghua University Graduate School at Shenzhen (No. ZDSYS20140509172959969).
Here the data: the new FLUXNET collection and the future for model-data integration
NASA Astrophysics Data System (ADS)
Papale, D.; Pastorello, G.; Trotta, C.; Chu, H.; Canfora, E.; Agarwal, D.; Baldocchi, D. D.; Torn, M. S.
2016-12-01
Seven years after the release of the LaThuile FLUXNET database, widely used in synthesis activities and model-data fusion exercises, a new FLUXNET collection has been released (FLUXNET 2015 - http://fluxnet.fluxdata.org) with the aim to increase the quality of the measurements and provide high quality standardized data obtained by a new processing pipeline. The new FLUXNET collection includes also sites with timeseries of 20 years of continuous carbon and energy fluxes, opening new opportunities in their use in the context of models parameterization and validation. The main characteristics of the FLUXNET 2015 dataset are the uncertainty quantification, the multiple products (e.g. partitioning in photosynthesis and ecosystem respiration) that allow consistency analysis for each site, and new long term downscaled meteorological data provided with the data. Feedbacks from new users, in particular from the modelling communities, are crucial to further improve the quality of the products and move in the direction of a coherent integration across multi-disciplinary communities. In this presentation, the new FLUXNET2015 dataset will be explained and explored, with particular focus on the meaning of the different products and variables, their potentiality but also their limitations. The future development of the dataset will be discussed, with the role of the regional networks and the ongoing efforts to provide new and advanced services such a near real time data provision and a completely open access policy to high quality standardized measurements of GHGs exchanges and additional ecological quantities.
Gliozzi, T M; Turri, F; Manes, S; Cassinelli, C; Pizzi, F
2017-11-01
Within recent years, there has been growing interest in the prediction of bull fertility through in vitro assessment of semen quality. A model for fertility prediction based on early evaluation of semen quality parameters, to exclude sires with potentially low fertility from breeding programs, would therefore be useful. The aim of the present study was to identify the most suitable parameters that would provide reliable prediction of fertility. Frozen semen from 18 Italian Holstein-Friesian proven bulls was analyzed using computer-assisted semen analysis (CASA) (motility and kinetic parameters) and flow cytometry (FCM) (viability, acrosomal integrity, mitochondrial function, lipid peroxidation, plasma membrane stability and DNA integrity). Bulls were divided into two groups (low and high fertility) based on the estimated relative conception rate (ERCR). Significant differences were found between fertility groups for total motility, active cells, straightness, linearity, viability and percentage of DNA fragmented sperm. Correlations were observed between ERCR and some kinetic parameters, and membrane instability and some DNA integrity indicators. In order to define a model with high relation between semen quality parameters and ERCR, backward stepwise multiple regression analysis was applied. Thus, we obtained a prediction model that explained almost half (R 2=0.47, P<0.05) of the variation in the conception rate and included nine variables: five kinetic parameters measured by CASA (total motility, active cells, beat cross frequency, curvilinear velocity and amplitude of lateral head displacement) and four parameters related to DNA integrity evaluated by FCM (degree of chromatin structure abnormality Alpha-T, extent of chromatin structure abnormality (Alpha-T standard deviation), percentage of DNA fragmented sperm and percentage of sperm with high green fluorescence representative of immature cells). A significant relationship (R 2=0.84, P<0.05) was observed between real and predicted fertility. Once the accuracy of fertility prediction has been confirmed, the model developed in the present study could be used by artificial insemination centers for bull selection or for elimination of poor fertility ejaculates.
NASA Astrophysics Data System (ADS)
Geng, Yu
With the increase of clock speed and wiring density in integrated circuits, inter-chip and intra-chip interconnects through conventional electrical wires encounter increasing difficulties because of the large power loss and bandwidth limitation. Optical interconnects have been proposed as an alternative to copper-based interconnects and are under intense study due to their large data capacity, high data quality and low power consumption. III-V compound semiconductors offer high intrinsic electron mobility, small effective electron mass and direct bandgap, which make this material system advantageous for high-speed optoelectronic devices. The integration of III-V optoelectronic devices on Si substrates will provide the combined advantage of a high level of integration and large volume production of Si-based electronic circuitry with the superior electrical and optical performance of III-V components, paving the way to a new generation of hybrid integrated circuits. In this thesis, the direct heteroepitaxy of photodetectors (PDs) and light emitters using metal-organic chemical vapor deposition for the integration of photonic devices on Si substrates were studied. First we studied the selective-area growth of InP/GaAs on patterned Si substrates for PDs. To overcome the loading effect, a multi-temperature composite growth technique for GaAs was developed. By decreasing various defects such as dislocations and anti-phase domains, the GaAs and InP buffer layers are with good crystalline quality and the PDs show high speed and low dark current performance both at the edge and center of the large growth well. Then the growth and fabrication of GaAs/AlGaAs QW lasers were studied. Ellipsometry was used to calibrate the Al composition of AlGaAs. Thick p and n type AlGaAs with a mirrorlike surface were grown by high V/III ratio and high temperature. The GaAs/AlGaAs broad area QW laser was successfully grown and fabricated on GaAs substrate and showed a pulsed lasing result with a threshold current density of about 800 A/cm2. For the integration of lasers on Si substrate, quantum dot (QD) lasers were studied. A flow-and-stop process of TBA was used to grow InAs QDs with the in-situ monitor EpiRas. QDs with a PL wavelength of ˜1.3 mum were grown on GaAs and Si substrates. To decrease the PL degradation problem caused by the contaminations from AlGaAs, an InGaAs insertion layer was inserted in between the AlGaAs and QDs region. Microdisk and a-Si waveguide lasers are designed and fabricated.
NASA Astrophysics Data System (ADS)
Xu, Xingyuan; Wu, Jiayang; Shoeiby, Mehrdad; Nguyen, Thach G.; Chu, Sai T.; Little, Brent E.; Morandotti, Roberto; Mitchell, Arnan; Moss, David J.
2018-01-01
An arbitrary-order intensity differentiator for high-order microwave signal differentiation is proposed and experimentally demonstrated on a versatile transversal microwave photonic signal processing platform based on integrated Kerr combs. With a CMOS-compatible nonlinear micro-ring resonator, high quality Kerr combs with broad bandwidth and large frequency spacings are generated, enabling a larger number of taps and an increased Nyquist zone. By programming and shaping individual comb lines' power, calculated tap weights are realized, thus achieving a versatile microwave photonic signal processing platform. Arbitrary-order intensity differentiation is demonstrated on the platform. The RF responses are experimentally characterized, and systems demonstrations for Gaussian input signals are also performed.
Hughes integrated synthetic aperture radar: High performance at low cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bayma, R.W.
1996-11-01
This paper describes the background and development of the low cost high-performance Hughes Integrated Synthetic Aperture Radar (HISAR{trademark}) which has a full range of capabilities for real-time reconnaissance, surveillance and earth resource mapping. HISAR uses advanced Synthetic Aperture Radar (SAR) technology to make operationally effective images of near photo quality, day or night and in all weather conditions. This is achieved at low cost by maximizing the use of commercially available radar and signal-processing equipment in the fabrication. Furthermore, HISAR is designed to fit into an executive-class aircraft making it available for a wide range of users. 4 refs., 8more » figs.« less
ERIC Educational Resources Information Center
Touchstone, Allison J. L.
2010-01-01
Dual credit programs have become increasingly popular with 71% U.S. public high schools offering dual credit courses in 2002-2003. As this popularity has grown, so have concerns regarding academic rigor, course quality, parity with college courses, and effects on higher education. Determining actual dual credit course equivalent in higher…
Safety issues of high-concentrated hydrogen peroxide production used as rocket propellant
NASA Astrophysics Data System (ADS)
Romantsova, O. V.; Ulybin, V. B.
2015-04-01
The article dwells on the possibility of production of high-concentrated hydrogen peroxide with the Russian technology of isopropyl alcohol autoxidation. Analysis of fire/explosion hazards and reasons of insufficient quality is conducted for the technology. Modified technology is shown. Non-standard fire/explosion characteristics required for integrated fire/explosion hazards rating for modified hydrogen peroxide production based on the autoxidation of isopropyl alcohol are defined.
USDA-ARS?s Scientific Manuscript database
To better understand, implement and integrate best management practices (BMPs) in agricultural watersheds, critical information on their effectiveness is required. A representative agricultural watershed, Beasley Lake, was used to compare runoff water quality draining through an integrated system of...
Chang, Hing-Chiu; Guhaniyogi, Shayan; Chen, Nan-kuei
2014-01-01
Purpose We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion weighted imaging (DWI). Methods First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction algorithm, so that images reconstructed from interleaved partial-Fourier DWI data are free from artifacts even in the presence of either a) motion-induced k-space energy peak displacement, or b) susceptibility field gradient induced fast phase changes. Second, we generalize the previously reported single-band MUSE framework to multi-band MUSE, so that both through-plane and in-plane aliasing artifacts in multi-band multi-shot interleaved DWI data can be effectively eliminated. Results The new adaptive Homodyne-MUSE reconstruction algorithm reliably produces high-quality and high-resolution DWI, eliminating residual artifacts in images reconstructed with previously reported methods. Furthermore, the generalized MUSE algorithm is compatible with multi-band and high-throughput DWI. Conclusion The integration of the multi-band and adaptive Homodyne-MUSE algorithms significantly improves the spatial-resolution, image quality, and scan throughput of interleaved DWI. We expect that the reported reconstruction framework will play an important role in enabling high-resolution DWI for both neuroscience research and clinical uses. PMID:24925000
Beddoe, Rachael; Costanza, Robert; Farley, Joshua; Garza, Eric; Kent, Jennifer; Kubiszewski, Ida; Martinez, Luz; McCowen, Tracy; Murphy, Kathleen; Myers, Norman; Ogden, Zach; Stapleton, Kevin; Woodward, John
2009-01-01
A high and sustainable quality of life is a central goal for humanity. Our current socio-ecological regime and its set of interconnected worldviews, institutions, and technologies all support the goal of unlimited growth of material production and consumption as a proxy for quality of life. However, abundant evidence shows that, beyond a certain threshold, further material growth no longer significantly contributes to improvement in quality of life. Not only does further material growth not meet humanity's central goal, there is mounting evidence that it creates significant roadblocks to sustainability through increasing resource constraints (i.e., peak oil, water limitations) and sink constraints (i.e., climate disruption). Overcoming these roadblocks and creating a sustainable and desirable future will require an integrated, systems level redesign of our socio-ecological regime focused explicitly and directly on the goal of sustainable quality of life rather than the proxy of unlimited material growth. This transition, like all cultural transitions, will occur through an evolutionary process, but one that we, to a certain extent, can control and direct. We suggest an integrated set of worldviews, institutions, and technologies to stimulate and seed this evolutionary redesign of the current socio-ecological regime to achieve global sustainability. PMID:19240221
Evolution of an innovative role: the clinical nurse leader.
Wilson, Lauri; Orff, Sonja; Gerry, Terilee; Shirley, Bobbi R; Tabor, Danielle; Caiazzo, Kathryn; Rouleau, Darlene
2013-01-01
This study describes the evolution of the clinical nurse leader (CNL(®) ) role and its utility in a tertiary care and community hospital. In the US, quality and safety metrics are being publically reported and healthcare organizations are just beginning to experience pay-for-performance and its impact. The American Association of the Colleges of Nursing (AACN) developed the role of the CNL to address the complexities and challenges of providing high-quality care in the current environment. Since 2007, a cohort of CNLs in practice has evaluated the effectiveness of the role with measures of clinical outcomes, financial savings and case studies. Having CNLs with a strategic perspective acting as facilitators and integrators of care has proven invaluable. Leadership support has been critical and commitment to maintaining the integrity of the role has ensured its success and sustainability. This role has established its value in risk assessment, strategic quality improvement, interdisciplinary collaboration and the implementation of evidence-based solutions. The flexibility and broad scope of this role allows for its use across practice settings and represents an exciting opportunity for nursing to drive quality of care to new levels while managing costs. © 2012 Blackwell Publishing Ltd.
Wafer-Scale Integration of Graphene-based Electronic, Optoelectronic and Electroacoustic Devices
Tian, He; Yang, Yi; Xie, Dan; Cui, Ya-Long; Mi, Wen-Tian; Zhang, Yuegang; Ren, Tian-Ling
2014-01-01
In virtue of its superior properties, the graphene-based device has enormous potential to be a supplement or an alternative to the conventional silicon-based device in varies applications. However, the functionality of the graphene devices is still limited due to the restriction of the high cost, the low efficiency and the low quality of the graphene growth and patterning techniques. We proposed a simple one-step laser scribing fabrication method to integrate wafer-scale high-performance graphene-based in-plane transistors, photodetectors, and loudspeakers. The in-plane graphene transistors have a large on/off ratio up to 5.34. And the graphene photodetector arrays were achieved with photo responsivity as high as 0.32 A/W. The graphene loudspeakers realize wide-band sound generation from 1 to 50 kHz. These results demonstrated that the laser scribed graphene could be used for wafer-scale integration of a variety of graphene-based electronic, optoelectronic and electroacoustic devices. PMID:24398542
NASA Astrophysics Data System (ADS)
Salach, A.; Markiewicza, J. S.; Zawieska, D.
2016-06-01
An orthoimage is one of the basic photogrammetric products used for architectural documentation of historical objects; recently, it has become a standard in such work. Considering the increasing popularity of photogrammetric techniques applied in the cultural heritage domain, this research examines the two most popular measuring technologies: terrestrial laser scanning, and automatic processing of digital photographs. The basic objective of the performed works presented in this paper was to optimize the quality of generated high-resolution orthoimages using integration of data acquired by a Z+F 5006 terrestrial laser scanner and a Canon EOS 5D Mark II digital camera. The subject was one of the walls of the "Blue Chamber" of the Museum of King Jan III's Palace at Wilanów (Warsaw, Poland). The high-resolution images resulting from integration of the point clouds acquired by the different methods were analysed in detail with respect to geometric and radiometric correctness.
NASA Astrophysics Data System (ADS)
Vasiliades, Lampros; Sidiropoulos, Pantelis; Tzabiras, John; Kokkinos, Konstantinos; Spiliotopoulos, Marios; Papaioannou, George; Fafoutis, Chrysostomos; Michailidou, Kalliopi; Tziatzios, George; Loukas, Athanasios; Mylopoulos, Nikitas
2015-04-01
Natural and engineered water systems interact throughout watersheds and while there is clearly a link between watershed activities and the quantity and quality of water entering the engineered environment, these systems are considered distinct operational systems. As a result, the strategic approach to data management and modeling within the two systems is very different, leading to significant difficulties in integrating the two systems in order to make comprehensive watershed decisions. In this paper, we describe the "HYDROMENTOR" research project, a highly-structured data storage and exchange system that integrates multiple tools and models describing both natural and modified environments, to provide an integrated tool for management of water resources. Our underlying objective in presenting our conceptual design for this water information system is to develop an integrated and automated system that will achieve monitoring and management of the water quantity and quality at watershed level for both surface water (rivers and lakes) and ground water resources (aquifers). The uniqueness of the system is the integrated treatment of the water resources management issue in terms of water quantity and quality in current climate conditions and in future conditions of climatic change. On an operational level, the system provides automated warnings when the availability, use and pollution levels exceed allowable limits pre-set by the management authorities. Decision making with respect to the apportionment of water use by surface and ground water resources are aided through this system, while the relationship between the polluting activity of a source to total incoming pollution by sources are determined; this way, the best management practices for dealing with a crisis are proposed. The computational system allows the development and application of actions, interventions and policies (alternative management scenarios) so that the impacts of climate change in quantity, quality and use of water resources could be evaluated and managed. Acknowledgements: This study has been supported by the research project "Hydromentor" funded by the Greek General Secretariat of Research and Technology in the framework of the E.U. co-funded National Action "Cooperation".
NASA Astrophysics Data System (ADS)
Shaw, Amelia R.; Smith Sawyer, Heather; LeBoeuf, Eugene J.; McDonald, Mark P.; Hadjerioua, Boualem
2017-11-01
Hydropower operations optimization subject to environmental constraints is limited by challenges associated with dimensionality and spatial and temporal resolution. The need for high-fidelity hydrodynamic and water quality models within optimization schemes is driven by improved computational capabilities, increased requirements to meet specific points of compliance with greater resolution, and the need to optimize operations of not just single reservoirs but systems of reservoirs. This study describes an important advancement for computing hourly power generation schemes for a hydropower reservoir using high-fidelity models, surrogate modeling techniques, and optimization methods. The predictive power of the high-fidelity hydrodynamic and water quality model CE-QUAL-W2 is successfully emulated by an artificial neural network, then integrated into a genetic algorithm optimization approach to maximize hydropower generation subject to constraints on dam operations and water quality. This methodology is applied to a multipurpose reservoir near Nashville, Tennessee, USA. The model successfully reproduced high-fidelity reservoir information while enabling 6.8% and 6.6% increases in hydropower production value relative to actual operations for dissolved oxygen (DO) limits of 5 and 6 mg/L, respectively, while witnessing an expected decrease in power generation at more restrictive DO constraints. Exploration of simultaneous temperature and DO constraints revealed capability to address multiple water quality constraints at specified locations. The reduced computational requirements of the new modeling approach demonstrated an ability to provide decision support for reservoir operations scheduling while maintaining high-fidelity hydrodynamic and water quality information as part of the optimization decision support routines.
Shaw, Amelia R.; Sawyer, Heather Smith; LeBoeuf, Eugene J.; ...
2017-10-24
Hydropower operations optimization subject to environmental constraints is limited by challenges associated with dimensionality and spatial and temporal resolution. The need for high-fidelity hydrodynamic and water quality models within optimization schemes is driven by improved computational capabilities, increased requirements to meet specific points of compliance with greater resolution, and the need to optimize operations of not just single reservoirs but systems of reservoirs. This study describes an important advancement for computing hourly power generation schemes for a hydropower reservoir using high-fidelity models, surrogate modeling techniques, and optimization methods. The predictive power of the high-fidelity hydrodynamic and water quality model CE-QUAL-W2more » is successfully emulated by an artificial neural network, then integrated into a genetic algorithm optimization approach to maximize hydropower generation subject to constraints on dam operations and water quality. This methodology is applied to a multipurpose reservoir near Nashville, Tennessee, USA. The model successfully reproduced high-fidelity reservoir information while enabling 6.8% and 6.6% increases in hydropower production value relative to actual operations for dissolved oxygen (DO) limits of 5 and 6 mg/L, respectively, while witnessing an expected decrease in power generation at more restrictive DO constraints. Exploration of simultaneous temperature and DO constraints revealed capability to address multiple water quality constraints at specified locations. Here, the reduced computational requirements of the new modeling approach demonstrated an ability to provide decision support for reservoir operations scheduling while maintaining high-fidelity hydrodynamic and water quality information as part of the optimization decision support routines.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaw, Amelia R.; Sawyer, Heather Smith; LeBoeuf, Eugene J.
Hydropower operations optimization subject to environmental constraints is limited by challenges associated with dimensionality and spatial and temporal resolution. The need for high-fidelity hydrodynamic and water quality models within optimization schemes is driven by improved computational capabilities, increased requirements to meet specific points of compliance with greater resolution, and the need to optimize operations of not just single reservoirs but systems of reservoirs. This study describes an important advancement for computing hourly power generation schemes for a hydropower reservoir using high-fidelity models, surrogate modeling techniques, and optimization methods. The predictive power of the high-fidelity hydrodynamic and water quality model CE-QUAL-W2more » is successfully emulated by an artificial neural network, then integrated into a genetic algorithm optimization approach to maximize hydropower generation subject to constraints on dam operations and water quality. This methodology is applied to a multipurpose reservoir near Nashville, Tennessee, USA. The model successfully reproduced high-fidelity reservoir information while enabling 6.8% and 6.6% increases in hydropower production value relative to actual operations for dissolved oxygen (DO) limits of 5 and 6 mg/L, respectively, while witnessing an expected decrease in power generation at more restrictive DO constraints. Exploration of simultaneous temperature and DO constraints revealed capability to address multiple water quality constraints at specified locations. Here, the reduced computational requirements of the new modeling approach demonstrated an ability to provide decision support for reservoir operations scheduling while maintaining high-fidelity hydrodynamic and water quality information as part of the optimization decision support routines.« less
Quality Assurance of Samples and Processes in the Spanish Renal Research Network (REDinREN) Biobank.
Calleros-Basilio, Laura; Cortés, María Alicia; García-Jerez, Andrea; Luengo-Rodríguez, Alicia; Orozco-Agudo, Ana; Valdivielso, José Manuel; Rodríguez-Puyol, Diego; Rodríguez-Puyol, Manuel
2016-12-01
Biobanks are useful platforms to build bridges between basic, translational, and clinical research and clinical care. They are repositories of high-quality human biological samples ideal for evaluating their histological characteristics and also their genome, transcriptome, and proteome. The Spanish Renal Research Network Biobank contains more than 76,500 well-preserved frozen samples of a wide variety of kidney diseases, collected from 5450 patients seen by over 70 nephrology services throughout the Spanish territory. To determine and to report the results of the quality control of samples and processes conducted in our biobank, implemented in accordance with the requirements of the ISO 9001:2008 international standard. Two types of quality controls were performed: (1) systematic, that is, measurement of viable peripheral blood mononuclear cells (PBMCs) obtained and purity of nucleic acids and (2) ad-hoc, that is, viability of thawed PBMC, DNA extraction process reproducibility, and the integrity and functionality of nucleic acids, implemented on a routine basis. PBMC isolation by Ficoll yielded reproducible results and its cryopreserved viability was >90%. Acceptable A260/A280 ratios were obtained for the vast majority of the DNA (n = 2328) and RNA (n = 78) samples analyzed. DNA integrity was demonstrated by agarose gels and by β-globulin gene polymerase chain reaction (PCR) amplification of 1327 and 989 bp fragments. DNA of acceptable quality had at least three bands of β-globulin amplified obtained (n = 26/30). RNA integrity number (RIN) determinations obtained RIN numbers ≥7 (n = 87/96). The amplifiability of nucleic acids was confirmed by qPCR and RT-qPCR of β-actin and GAPDH genes. Long storage or delayed processing time did not affect the quality of the samples analyzed. The processes of DNA extraction also yielded reproducible results. These results clearly indicate that our PBMC, DNA, and RNA stored samples meet the required quality standards to be used for biomedical research, ensuring their long-term preservation.
2014-01-01
Background Modern watermelon (Citrullus lanatus L.) cultivars share a narrow genetic base due to many years of selection for desirable horticultural qualities. Wild subspecies within C. lanatus are important potential sources of novel alleles for watermelon breeding, but successful trait introgression into elite cultivars has had limited success. The application of marker assisted selection (MAS) in watermelon is yet to be realized, mainly due to the past lack of high quality genetic maps. Recently, a number of useful maps have become available, however these maps have few common markers, and were constructed using different marker sets, thus, making integration and comparative analysis among maps difficult. The objective of this research was to use single-nucleotide polymorphism (SNP) anchor markers to construct an integrated genetic map for C. lanatus. Results Under the framework of the high density genetic map, an integrated genetic map was constructed by merging data from four independent mapping experiments using a genetically diverse array of parental lines, which included three subspecies of watermelon. The 698 simple sequence repeat (SSR), 219 insertion-deletion (InDel), 36 structure variation (SV) and 386 SNP markers from the four maps were used to construct an integrated map. This integrated map contained 1339 markers, spanning 798 cM with an average marker interval of 0.6 cM. Fifty-eight previously reported quantitative trait loci (QTL) for 12 traits in these populations were also integrated into the map. In addition, new QTL identified for brix, fructose, glucose and sucrose were added. Some QTL associated with economically important traits detected in different genetic backgrounds mapped to similar genomic regions of the integrated map, suggesting that such QTL are responsible for the phenotypic variability observed in a broad array of watermelon germplasm. Conclusions The integrated map described herein enhances the utility of genomic tools over previous watermelon genetic maps. A large proportion of the markers in the integrated map are SSRs, InDels and SNPs, which are easily transferable across laboratories. Moreover, the populations used to construct the integrated map include all three watermelon subspecies, making this integrated map useful for the selection of breeding traits, identification of QTL, MAS, analysis of germplasm and commercial hybrid seed detection. PMID:24443961
ERIC Educational Resources Information Center
Fleming, Steven T.
1992-01-01
The concept of risk-adjusted measures of quality is discussed, and a methodology is proposed for risk-adjusting and integrating multiple adverse outcomes of anesthesia services into measures for quality assurance and quality improvement programs. Although designed for a new anesthesiology database, the methods should apply to other health…
Collaborative transdisciplinary team approach for dementia care
Galvin, James E; Valois, Licet; Zweig, Yael
2015-01-01
SUMMARY Alzheimer's disease (AD) has high economic impact and places significant burden on patients, caregivers, providers and healthcare delivery systems, fostering the need for an evaluation of alternative approaches to healthcare delivery for dementia. Collaborative care models are team-based, multicomponent interventions that provide a pragmatic strategy to deliver integrated healthcare to patients and families across a wide range of populations and clinical settings. Healthcare reform and national plans for AD goals to integrate quality care, health promotion and preventive services, and reduce the impact of disease on patients and families reinforcing the need for a system-level evaluation of how to best meet the needs of patients and families. We review collaborative care models for AD and offer evidence for improved patient- and family-centered outcomes, quality indicators of care and potential cost savings. PMID:25531688
NASA Astrophysics Data System (ADS)
Lefer, B. L.; Crawford, J. H.; Pierce, R. B.; Berkoff, T.; Swap, R.; Janz, S. J.; Ahn, J.; Al-Saadi, J. A.
2017-12-01
With the launch over the virtual constellation of earth observing satellites for atmospheric composition (e.g., TROPOMI, GEMS, TEMPO, and Sentinel-4) over the next several years, we have a unique opportunity to develop an Integrated Observing System (IOS) for air quality in the northern hemisphere. Recently, NASA's Tropospheric Composition Program (TCP) has participated in several different air quality related field campaigns as an effort to explore various prototypes of the IOS for Air Quality. The IOS for air quality could be a system were space-based observations of air quality (generally, column abundances of NO2, HCHO, O3, SO2, and AOD) are given added "value" by being integrated with: a) long-term ground-based observations;b) regional and global air quality and chemical transport models; as well as c) measurements from targeted airborne field campaigns. The recent Korea-US Air Quality Study (KORUS-AQ), the Lake Michigan Ozone Study 2017 (LMOS), and the Ozone Water-Land Environmental Transition Study (OWLETS) field campaigns were held in different locations and made measurements over different scale. However, all of these provide an opportunity to learn about how a future integrated air quality observing system can be implemented to serve a variety of air quality related objectives. NASA TCP is also exploring enchancements to our routine observations to strengthen the IOS for air quality in the future.
Creating value-focused healthcare delivery systems: Part three--Core competencies.
Beveridge, R N
1997-01-01
Value is created through the delivery of high-quality, cost--effective healthcare services. The ability to create value from the providers' perspective is facilitated through the development and implementation of essential, customer-focused core competencies. These core competencies include customer relationship management, payer/provider relationship management, disease management, outcomes management, financial/cost management, and information management. Customer relationship management is the foundation upon which all core competencies must be built. All of the core competencies must focus on the needs of the customers, both internal and external. Structuring all processes involved in the core competencies from the perspective of the customer will ensure that value is created throughout the system. Payer/provider relationship management will become a crucial pillar for healthcare providers in the future. As more vertical integration among providers occurs, the management of the relationships among providers and with payers will become more important. Many of the integration strategies being implemented across the country involve the integration of hospitals, physicians, and payers to form accountable health plans. The relationships must be organized to form "win/win" situations, where all parties are focused on a shared vision of creating value and none of the parties benefits at the expense of the others. Disease management in creating value requires that we begin examining the disease process along the entire continuum. Not only must providers be able to provide high-quality acute and chronic care, but they must also begin to focus more heavily on programs of prevention. Value is created throughout the system through reducing the prevalence and incidence of disease. Only through managing the full continuum of health will value be created throughout the healthcare delivery system. Outcomes management ensures that the outcomes are the highest quality at a cost-effective price. Outcomes must not only be compared to best practices, but to what is possible. Providers must constantly strive to enhance the quality of the services. Financial/cost management ensures that care is cost-effective and that a marginal profit is maintained to allow continued investment in new technology and continuing medical education to enhance the quality of care and lifestyles for all stakeholders. Information management is the binding element, or keystone, in providing value-focused care. Through the collection, storing, transfer, manipulation, sorting, and reporting of data, more effective decision-making can occur. Integrated MIS allows information to be generated about the cost-effectiveness of treatment regimens, employee productivity, physician cost-effectiveness, supply utilization, and clinical outcomes, as well as patient information to be readily available throughout the healthcare system. Having this information available will allow providers to become more cost-effective in the delivery of care, which results in perceived higher value for the services. Customers demand value. Value is created by meeting the needs and demands of the customers through the delivery of cost-effective, high-quality healthcare services that are easily accessible and meet with high patient satisfaction. Providers who can demonstrate their ability to provide the services in this manner will create a competitive advantage in the marketplace and will be perceived as the value provider of choice by loyal customers.
NASA Astrophysics Data System (ADS)
Belenguer, Angel; Cano, Juan Luis; Esteban, Héctor; Artal, Eduardo; Boria, Vicente E.
2017-01-01
Substrate integrated circuits (SIC) have attracted much attention in the last years because of their great potential of low cost, easy manufacturing, integration in a circuit board, and higher-quality factor than planar circuits. A first suite of SIC where the waves propagate through dielectric have been first developed, based on the well-known substrate integrated waveguide (SIW) and related technological implementations. One step further has been made with a new suite of empty substrate integrated waveguides, where the waves propagate through air, thus reducing the associated losses. This is the case of the empty substrate integrated waveguide (ESIW) or the air-filled substrate integrated waveguide (air-filled SIW). However, all these SIC are H plane structures, so classical H plane solutions in rectangular waveguides have already been mapped to most of these new SIC. In this paper a novel E plane empty substrate integrated waveguide (ESIW-E) is presented. This structure allows to easily map classical E plane solutions in rectangular waveguide to this new substrate integrated solution. It is similar to the ESIW, although more layers are needed to build the structure. A wideband transition (covering the frequency range between 33 GHz and 50 GHz) from microstrip to ESIW-E is designed and manufactured. Measurements are successfully compared with simulation, proving the validity of this new SIC. A broadband high-frequency phase shifter (for operation from 35 GHz to 47 GHz) is successfully implemented in ESIW-E, thus proving the good performance of this new SIC in a practical application.
Osterholt, Dawn M; Onikpo, Faustin; Lama, Marcel; Deming, Michael S; Rowe, Alexander K
2009-01-01
Background Pneumonia is a leading cause of death among children under five years of age. The Integrated Management of Childhood Illness strategy can improve the quality of care for pneumonia and other common illnesses in developing countries, but adherence to these guidelines could be improved. We evaluated an intervention in Benin to support health worker adherence to the guidelines after training, focusing on pneumonia case management. Methods We conducted a randomized trial. After a health facility survey in 1999 to assess health care quality before Integrated Management of Childhood Illness training, health workers received training plus either study supports (job aids, non-financial incentives and supervision of workers and supervisors) or "usual" supports. Follow-up surveys were conducted in 2001, 2002 and 2004. Outcomes were indicators of health care quality for Integrated Management-defined pneumonia. Further analyses included a graphical pathway analysis and multivariable logistic regression modelling to identify factors influencing case-management quality. Results We observed 301 consultations of children with non-severe pneumonia that were performed by 128 health workers in 88 public and private health facilities. Although outcomes improved in both intervention and control groups, we found no statistically significant difference between groups. However, training proceeded slowly, and low-quality care from untrained health workers diluted intervention effects. Per-protocol analyses suggested that health workers with training plus study supports performed better than those with training plus usual supports (20.4 and 19.2 percentage-point improvements for recommended treatment [p = 0.08] and "recommended or adequate" treatment [p = 0.01], respectively). Both groups tended to perform better than untrained health workers. Analyses of treatment errors revealed that incomplete assessment and difficulties processing clinical findings led to missed pneumonia diagnoses, and missed diagnoses led to inadequate treatment. Increased supervision frequency was associated with better care (odds ratio for recommended treatment = 2.1 [95% confidence interval: 1.1-3.9] per additional supervisory visit). Conclusion Integrated Management of Childhood Illness training was useful, but insufficient, to achieve high-quality pneumonia case management. Our study supports led to additional improvements, although large gaps in performance still remained. A simple graphical pathway analysis can identify specific, common errors that health workers make in the case-management process; this information could be used to target quality improvement activities, such as supervision (ClinicalTrials.gov number NCT00510679). PMID:19712484
The effect of teacher quality on the achievement of students in Integrated Physics and Chemistry
NASA Astrophysics Data System (ADS)
Alexander, Rima
For many years, researchers, policy makers, and the education community have explored various school variables and their impact on student achievement (Darling-Hammond, 2000; Ferguson and Womack 1993; Ferguson and Ladd 1996; Rice, 2003; Rockoff, 2003; Rowan, Chiang, and Miller 1997; Sanders and Horn, 1996; Wright Horn and Sanders, 1997). Invariably, the issue of teacher quality arises. Teacher quality is the single most influential factor under school control that affects student achievement (Darling-Hammond, 2000; Rice, 2003; Rockoff, 2003; Sanders and Horn, 1996; Wright Horn and Sanders, 1997). Generally, students taught by highly qualified teachers perform better on standardized tests than students with less qualified teachers (Ferguson and Womack 1993; Ferguson and Ladd 1996; Rowan, Chiang, and Miller 1997). Previous research indicates that teachers indeed matter for the improvement of student achievement, but getting good measures of what is meant by teacher quality is a continuing challenge (Goldhaber, 2002). The purpose of this study was to describe the effect of teacher quality on the achievement of students in Integrated Physics and Chemistry (IPC). In order to achieve this purpose, this study addressed the following research question: chemistry and physics teachers compare to the achievement of students taught by less-qualified IPC teachers? A causal-comparative methodology was employed to address this research question. The independent variable was teacher quality---highly-qualified or less qualified. The teacher attributes that were examined in this study are: (1) teachers' educational background; (2) content knowledge; (3) pedagogical knowledge; and (4) certification. The dependent variable was student achievement in integrated physics and chemistry, as measured by an end-of-course IPC District Assessment of Curriculum, IPC DAC. Descriptive statistics were computed for the independent variable in the study. A Chi Square was performed on the data, utilizing SPSS version 12.0.1 software. Next a test of statistical significance was done to determine whether the null hypothesis could be rejected; and whether or not the research hypothesis could be accepted. Since this is a causal comparative design with only two groups in which student achievement was measured by a test that will yield raw scores, a Chi Square was conducted to determine whether the pass rates of the two groups of students based on obtained and expected percentages were statistically significantly different A Chi Square value of 4.29 was obtained, which indicates that the pass rate for students of highly-qualified teachers was statistically significantly higher than for students of less-qualified teachers. For the purpose of this study a criterion value of (p<.05) was used.
NASA Astrophysics Data System (ADS)
Uriguen, Monica I.
This study sought to identify the key attributes of high-quality programs with an eye toward helping developing countries such as Ecuador advance program quality. The dissertation is divided into five chapters: (1) introduction to high-quality programs; (2) literature review of attributes of high-quality programs; (3) grounded theory method (including interviews with 60 individuals) used to identify program attributes that enhance student learning; (4) findings; and (5) conclusions and recommendations. Following are the five clusters and thirteen attributes of high-quality programs that I identified: Cluster One: Highly Qualified Participants: (1) Highly Qualified Faculty, and (2) Highly Qualified Students; Cluster Two: Learning-Centered Cultures: (3) Shared Program Direction Focused on Learning, (4) Real-World Learning Experiences, (5) Reading-Centered Culture, and (6) Supportive and Risk-Taking Environment; Cluster Three: Interactive Teaching and Learning: (7) Integrative learning: Theory with Practice, Self with Subject, and (8) Exclusive Tutoring and Mentoring; Cluster Four: Connected Program Requirements: (9) Planned Breadth and Depth Course Work, and (10) Tangible Products; and Cluster Five: Adequate Resources: (11) Support for Students, (12) Support for Faculty, and (13) Support for Campus Infrastructure. The study was guided by Haworth and Conrad's (1997) "Engagement Theory of High-Quality Programs." Eleven of the attributes of high-quality programs are closely connected to Haworth and Conrad's theory and the other two attributes---real-world learning experiences and a reading-centered culture---make the signature theoretical contributions of the study. Real-world learning experiences encourage the active involvement of stakeholders in designing curricula with real-world learning experiences. The second attribute---a reading-centered culture---has never before been identified in the literature. There are four key differences between Haworth and Conrad's theory and the theory developed in this study. This study identified four attributes that are highly important in Ecuador and, possibly, other developing countries: highly-qualified faculty, highly-qualified students, reading-centered cultures, and real-world learning experiences. If Latin American universities implement the recommendations proposed in the study, particularly Ecuadorian universities, there is a foundation for envisioning a better future for Ecuadorian universities.
Design and Implementation of Total Quality Management in a Civil Engineering Squadron
1989-09-01
instruct employees and seek new ways to integrate quality into all functions, such as planning, marketing , and controlling. The second strategy is for...implement a TQM plan that contributes to the overall DOD TQM process. 7 2. Managers at all levels will provide leadership and integrate TQM principles... integral part of our daily activities. 8 3. Quality improvement is the key to productivity improvement and must be pursued with the necessary resources to
NASA Astrophysics Data System (ADS)
Akhavan Niaki, Farbod
The objective of this research is first to investigate the applicability and advantage of statistical state estimation methods for predicting tool wear in machining nickel-based superalloys over deterministic methods, and second to study the effects of cutting tool wear on the quality of the part. Nickel-based superalloys are among those classes of materials that are known as hard-to-machine alloys. These materials exhibit a unique combination of maintaining their strength at high temperature and have high resistance to corrosion and creep. These unique characteristics make them an ideal candidate for harsh environments like combustion chambers of gas turbines. However, the same characteristics that make nickel-based alloys suitable for aggressive conditions introduce difficulties when machining them. High strength and low thermal conductivity accelerate the cutting tool wear and increase the possibility of the in-process tool breakage. A blunt tool nominally deteriorates the surface integrity and damages quality of the machined part by inducing high tensile residual stresses, generating micro-cracks, altering the microstructure or leaving a poor roughness profile behind. As a consequence in this case, the expensive superalloy would have to be scrapped. The current dominant solution for industry is to sacrifice the productivity rate by replacing the tool in the early stages of its life or to choose conservative cutting conditions in order to lower the wear rate and preserve workpiece quality. Thus, monitoring the state of the cutting tool and estimating its effects on part quality is a critical task for increasing productivity and profitability in machining superalloys. This work aims to first introduce a probabilistic-based framework for estimating tool wear in milling and turning of superalloys and second to study the detrimental effects of functional state of the cutting tool in terms of wear and wear rate on part quality. In the milling operation, the mechanisms of tool failure were first identified and, based on the rapid catastrophic failure of the tool, a Bayesian inference method (i.e., Markov Chain Monte Carlo, MCMC) was used for parameter calibration of tool wear using a power mechanistic model. The calibrated model was then used in the state space probabilistic framework of a Kalman filter to estimate the tool flank wear. Furthermore, an on-machine laser measuring system was utilized and fused into the Kalman filter to improve the estimation accuracy. In the turning operation the behavior of progressive wear was investigated as well. Due to the nonlinear nature of wear in turning, an extended Kalman filter was designed for tracking progressive wear, and the results of the probabilistic-based method were compared with a deterministic technique, where significant improvement (more than 60% increase in estimation accuracy) was achieved. To fulfill the second objective of this research in understanding the underlying effects of wear on part quality in cutting nickel-based superalloys, a comprehensive study on surface roughness, dimensional integrity and residual stress was conducted. The estimated results derived from a probabilistic filter were used for finding the proper correlations between wear, surface roughness and dimensional integrity, along with a finite element simulation for predicting the residual stress profile for sharp and worn cutting tool conditions. The output of this research provides the essential information on condition monitoring of the tool and its effects on product quality. The low-cost Hall effect sensor used in this work to capture spindle power in the context of the stochastic filter can effectively estimate tool wear in both milling and turning operations, while the estimated wear can be used to generate knowledge of the state of workpiece surface integrity. Therefore the true functionality and efficiency of the tool in superalloy machining can be evaluated without additional high-cost sensing.
Separate-Subject and Integrated Approaches to Social Education
ERIC Educational Resources Information Center
Hughes, Andrew S.
1978-01-01
Comparing separate subject approach with an integrated approach to social studies instruction, it was found that neither approach taught process skills or changed student attitude; that integrated classes used more evaluative questions and were less teacher dominated; and that educational quality is related more to teacher quality than to…
Defining quality health care with outcomes assessment while achieving economic value.
Shaw, L J; Miller, D D
2000-02-01
The effectiveness of a procedure is increasingly guided by the evaluation of patient outcomes. Outcomes data is used to develop clinical pathways of care and to define appropriate resource-use levels without sacrificing quality of care. Integration of the economic implications of medical services into an outcome-based guideline allows for the development of disease-management strategies. In cardiovascular medicine, risk reduction is associated with high cost due to the "pay-back" of new technologies and therapies. A major challenge is to define a balance between "high tech" care and cost. This paper devises an outpatient evidence-based guideline using clinical and economic outcomes data for the diagnosis of coronary disease.
Development and flight test results of an autothrottle control system at Mach 3 cruise
NASA Technical Reports Server (NTRS)
Gilyard, G. B.; Burken, J. J.
1980-01-01
Flight test results obtained with the original Mach hold autopilot designed the YF-12C airplane which uses elevator control and a newly developed Mach hold system having an autothrottle integrated with an altitude hold autopilot system are presented. The autothrottle tests demonstrate good speed control at high Mach numbers and high altitudes while simultaneously maintaining control over altitude and good ride qualities. The autothrottle system was designed to control either Mach number or knots equivalent airspeed (KEAS). Excellent control of Mach number or KEAS was obtained with the autothrottle system when combined with altitude hold. Ride qualities were significantly better than with the conventional Mach hold system.
Integrated continuous processing of proteins expressed as inclusion bodies: GCSF as a case study.
Kateja, Nikhil; Agarwal, Harshit; Hebbi, Vishwanath; Rathore, Anurag S
2017-07-01
Affordability of biopharmaceuticals continues to be a challenge, particularly in developing economies. This has fuelled advancements in manufacturing that can offer higher productivity and better economics without sacrificing product quality in the form of an integrated continuous manufacturing platform. While platform processes for monoclonal antibodies have existed for more than a decade, development of an integrated continuous manufacturing process for bacterial proteins has received relatively scant attention. In this study, we propose an end-to-end integrated continuous downstream process (from inclusion bodies to unformulated drug substance) for a therapeutic protein expressed in Escherichia coli as inclusion body. The final process consisted of a continuous refolding in a coiled flow inverter reactor directly coupled to a three-column periodic counter-current chromatography for capture of the product followed by a three-column con-current chromatography for polishing. The continuous bioprocessing train was run uninterrupted for 26 h to demonstrate its capability and the resulting output was analyzed for the various critical quality attributes, namely product purity (>99%), high molecular weight impurities (<0.5%), host cell proteins (<100 ppm), and host cell DNA (<10 ppb). All attributes were found to be consistent over the period of operation. The developed assembly offers smaller facility footprint, higher productivity, fewer hold steps, and significantly higher equipment and resin utilization. The complexities of process integration in the context of continuous processing have been highlighted. We hope that the study presented here will promote development of highly efficient, universal, end-to-end, fully continuous platforms for manufacturing of biotherapeutics. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 33:998-1009, 2017. © 2016 American Institute of Chemical Engineers.
Delbes, G; Herrero, M B; Troeung, E-T; Chan, P T K
2013-09-01
Sperm chromatin integrity may affect the outcomes of assisted reproductive technology (ART). Developing a clinically reliable strategy to enrich sperm samples with high chromatin quality spermatozoa prior to sperm banking or use in ART would thus be advantageous. The objectives of this study were to: (i) assess the sperm chromatin quality in men with different categories of semen parameters; and (ii) evaluate the extents of Annexin-V magnetic-activated cell sorting (MACS) technology coupled with differential density gradient centrifugation (DGC) in improving sperm chromatin quality. Three categories of men from couples attending a university-based fertility clinic were recruited based on their semen parameters: normozoospermic (n = 13), asthenoteratozoospermic (n = 17) and teratozoospermic (n = 12). For each patient, spermatozoa in semen samples were processed first by DGC to enrich the motility and further by MACS to remove spermatozoa showing apoptotic features. The yield and enrichment of sperm quality was evaluated at each step with conventional semen parameters in conjunction with a combination of five complementary assays, to assess sperm maturity, chromatin structure, compaction and DNA integrity (Hyaluronic Binding Assay, SCSA, chromomycine A3 staining and TUNEL and COMET assays). Our results demonstrated that, compared with normozoospermic samples, raw asthenoteratozoospermic and teratozoospermic samples had a higher proportion of spermatozoa containing DNA breaks, but only asthenoteratozoospermic exhibited altered chromatin structure and decreased binding to hyaluronic acid. Interestingly, the DGC appeared to select for more mature spermatozoa with high DNA compaction. More importantly, in all categories of semen samples, Annexin-V MACS allows enrichment of spermatozoa with good chromatin quality as measured by the TUNEL and SCSA. Because effective treatment modalities to improve sperm DNA damage are limited, our results suggest a potential clinical value of MACS as a mean to enhance sperm quality that may improve assisted reproductive outcomes. © 2013 American Society of Andrology and European Academy of Andrology.
Data governance in predictive toxicology: A review.
Fu, Xin; Wojak, Anna; Neagu, Daniel; Ridley, Mick; Travis, Kim
2011-07-13
Due to recent advances in data storage and sharing for further data processing in predictive toxicology, there is an increasing need for flexible data representations, secure and consistent data curation and automated data quality checking. Toxicity prediction involves multidisciplinary data. There are hundreds of collections of chemical, biological and toxicological data that are widely dispersed, mostly in the open literature, professional research bodies and commercial companies. In order to better manage and make full use of such large amount of toxicity data, there is a trend to develop functionalities aiming towards data governance in predictive toxicology to formalise a set of processes to guarantee high data quality and better data management. In this paper, data quality mainly refers in a data storage sense (e.g. accuracy, completeness and integrity) and not in a toxicological sense (e.g. the quality of experimental results). This paper reviews seven widely used predictive toxicology data sources and applications, with a particular focus on their data governance aspects, including: data accuracy, data completeness, data integrity, metadata and its management, data availability and data authorisation. This review reveals the current problems (e.g. lack of systematic and standard measures of data quality) and desirable needs (e.g. better management and further use of captured metadata and the development of flexible multi-level user access authorisation schemas) of predictive toxicology data sources development. The analytical results will help to address a significant gap in toxicology data quality assessment and lead to the development of novel frameworks for predictive toxicology data and model governance. While the discussed public data sources are well developed, there nevertheless remain some gaps in the development of a data governance framework to support predictive toxicology. In this paper, data governance is identified as the new challenge in predictive toxicology, and a good use of it may provide a promising framework for developing high quality and easy accessible toxicity data repositories. This paper also identifies important research directions that require further investigation in this area.
Data governance in predictive toxicology: A review
2011-01-01
Background Due to recent advances in data storage and sharing for further data processing in predictive toxicology, there is an increasing need for flexible data representations, secure and consistent data curation and automated data quality checking. Toxicity prediction involves multidisciplinary data. There are hundreds of collections of chemical, biological and toxicological data that are widely dispersed, mostly in the open literature, professional research bodies and commercial companies. In order to better manage and make full use of such large amount of toxicity data, there is a trend to develop functionalities aiming towards data governance in predictive toxicology to formalise a set of processes to guarantee high data quality and better data management. In this paper, data quality mainly refers in a data storage sense (e.g. accuracy, completeness and integrity) and not in a toxicological sense (e.g. the quality of experimental results). Results This paper reviews seven widely used predictive toxicology data sources and applications, with a particular focus on their data governance aspects, including: data accuracy, data completeness, data integrity, metadata and its management, data availability and data authorisation. This review reveals the current problems (e.g. lack of systematic and standard measures of data quality) and desirable needs (e.g. better management and further use of captured metadata and the development of flexible multi-level user access authorisation schemas) of predictive toxicology data sources development. The analytical results will help to address a significant gap in toxicology data quality assessment and lead to the development of novel frameworks for predictive toxicology data and model governance. Conclusions While the discussed public data sources are well developed, there nevertheless remain some gaps in the development of a data governance framework to support predictive toxicology. In this paper, data governance is identified as the new challenge in predictive toxicology, and a good use of it may provide a promising framework for developing high quality and easy accessible toxicity data repositories. This paper also identifies important research directions that require further investigation in this area. PMID:21752279
Cost and quality impact of Intermountain's mental health integration program.
Reiss-Brennan, Brenda; Briot, Pascal C; Savitz, Lucy A; Cannon, Wayne; Staheli, Russ
2010-01-01
Most patients with mental health (MH) conditions, such as depression, receive care for their conditions from a primary care physician (PCP) in their health/medical home. Providing MH care, however, presents many challenges for the PCP, including (1) the difficulty of getting needed consultation from an MH specialist; (2) the time constraints of a busy PCP practice; (3) the complicated nature of recognizing depression, which may be described with only somatic complaints; (4) the barriers to reimbursement and compensation; and (5) associated medical and social comorbidities. Practice managers, emergency departments, and health plans are stretched to provide care for complex patients with unmet MH needs. At the same time, payment reform linked to accountable care organizations and/or episodic bundle payments, MH parity rules, and increasing MH costs to large employers and payers all highlight the critical need to identify high-quality, efficient, integrated MH care delivery practices. Over the past ten years, Intermountain Healthcare has developed a team-based approach-known as mental health integration (MHI)-for caring for these patients and their families. The team includes the PCPs and their staff, and they, in turn, are integrated with MH professionals, community resources, care management, and the patient and his or her family. The integration model goes far beyond co-location in its team-based approach; it is operationalized at the clinic, thereby improving both physician and staff satisfaction. Patients treated in MHI clinics also show improved satisfaction, lower costs, and better quality outcomes. The MHI program is financially sustainable in routinized clinics without subsidies. MHI is a successful approach to improving care for patients with MH conditions in primary care health homes.
NASA Astrophysics Data System (ADS)
Ma, Xing; Wang, Jun; Cheng, Zhuo; Yang, Zeyuan; Hu, Haiyang; Wang, Wei; Yin, Haiying; Huang, Yongqing; Ren, Xiaomin
2018-07-01
We report a structure design of 1.55 μm square microcavity lasers monolithically integrated on GaAs substrates. The mode characteristics of the microcavity lasers are numerically investigated by three-dimensional finite-difference time-domain method. The dependences of the high-quality factor modes on the side length of the microcavity, the width of the output waveguide and the etching depth are investigated in detail. The results demonstrate, for the microcavity structure with the side length of 12 μm, the output waveguide width of 1.0 μm and the etching depth of 3.55 μm, it is optimal to excite high-quality factor modes around wavelength of 1.55 μm. The mode wavelength and the mode quality factor are 1547.46 nm and 2416.28, respectively. The quality factor degrades rapidly with the waveguide width increasing, and increases with increasing etching depth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hicks, Michael; Erickson, Paul; Lawrence, Richard
Off-road concerns are related to the effects of shock and vibration and air quality on fuel cell power requirements. Mechanical stresses on differing material makeup and mass distribution within the system may render some components susceptible to impulse trauma while others may show adverse effects from harmonic disturbances or broad band mechanical agitation. One of the recognized challenges in fuel cell systems air purification is in providing a highly efficient particulate and chemical filter with minimal pressure drop. PEM integrators do not want additional parasitic loads added to the system as compensation for a highly efficient yet highly restrictive filter.more » Additionally, there is challenge in integrating multiple functions into a single air intake module tasked with effectively filtering high dust loads, diesel soot, pesticides, ammonias, and other anticipated off-road contaminants. This project has investigated both off-road associated issues cumulating in the prototype build and testing of two light duty off-road vehicles with integrated fuel cell power plant systems.« less
INTEGRATED POWER GENERATION SYSTEMS FOR COAL MINE WASTE METHANE UTILIZATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peet M. Soot; Dale R. Jesse; Michael E. Smith
2005-08-01
An integrated system to utilize the waste coal mine methane (CMM) at the Federal No. 2 Coal Mine in West Virginia was designed and built. The system includes power generation, using internal combustion engines, along with gas processing equipment to upgrade sub-quality waste methane to pipeline quality standards. The power generation has a nominal capacity of 1,200 kw and the gas processing system can treat about 1 million cubic feet per day (1 MMCFD) of gas. The gas processing is based on the Northwest Fuel Development, Inc. (NW Fuel) proprietary continuous pressure swing adsorption (CPSA) process that can remove nitrogenmore » from CMM streams. The two major components of the integrated system are synergistic. The byproduct gas stream from the gas processing equipment can be used as fuel for the power generating equipment. In return, the power generating equipment provides the nominal power requirements of the gas processing equipment. This Phase III effort followed Phase I, which was comprised of a feasibility study for the project, and Phase II, where the final design for the commercial-scale demonstration was completed. The fact that NW Fuel is desirous of continuing to operate the equipment on a commercial basis provides the validation for having advanced the project through all of these phases. The limitation experienced by the project during Phase III was that the CMM available to operate the CPSA system on a commercial basis was not of sufficiently high quality. NW Fuel's CPSA process is limited in its applicability, requiring a relatively high quality of gas as the feed to the process. The CPSA process was demonstrated during Phase III for a limited time, during which the processing capabilities met the expected results, but the process was never capable of providing pipeline quality gas from the available low quality CMM. The NW Fuel CPSA process is a low-cost ''polishing unit'' capable of removing a few percent nitrogen. It was never intended to process CMM streams containing high levels of nitrogen, as is now the case at the Federal No.2 Mine. Even lacking the CPSA pipeline delivery demonstration, the project was successful in laying the groundwork for future commercial applications of the integrated system. This operation can still provide a guide for other coal mines which need options for utilization of their methane resources. The designed system can be used as a complete template, or individual components of the system can be segregated and utilized separately at other mines. The use of the CMM not only provides an energy fuel from an otherwise wasted resource, but it also yields an environmental benefit by reducing greenhouse gas emissions. The methane has twenty times the greenhouse effect as compared to carbon dioxide, which the combustion of the methane generates. The net greenhouse gas emission mitigation is substantial.« less
Surgical pathology report in the era of desktop publishing.
Pillarisetti, S G
1993-01-01
Since it is believed that "a picture is worth a thousand words," incorporation of computer-generated line art was used as a adjunct to gross description in surgical pathology reporting in selected cases. The lack of an integrated software program was overcome by using commercially available graphic and word processing software. A library of drawings was developed over the last few years. Most time-consuming is the development of templates and the graphic library. With some effort it is possible to integrate graphics of high quality into surgical pathology reports.
NASA Astrophysics Data System (ADS)
Politi, Violetta
2018-03-01
The paper considers environmental problems arising during the implementation of housing programs for the integrated development of territories by high-rise buildings. The need to assess the quality of the environment in the functional zoning of territories is identified and a calculation of the index of the ecological potential of the territories is proposed. The main stages of organization of construction of environmental real estate and the introduction of energy-saving and resource-saving technologies at the regional level are formulated
Integrated care programmes for adults with chronic conditions: a meta-review.
Martínez-González, Nahara Anani; Berchtold, Peter; Ullman, Klara; Busato, André; Egger, Matthias
2014-10-01
To review systematic reviews and meta-analyses of integrated care programmes in chronically ill patients, with a focus on methodological quality, elements of integration assessed and effects reported. Meta-review of systematic reviews and meta-analyses identified in Medline (1946-March 2012), Embase (1980-March 2012), CINHAL (1981-March 2012) and the Cochrane Library of Systematic Reviews (issue 1, 2012). Methodological quality assessed by the 11-item Assessment of Multiple Systematic Reviews (AMSTAR) checklist; elements of integration assessed using a published list of 10 key principles of integration; effects on patient-centred outcomes, process quality, use of healthcare and costs. Twenty-seven systematic reviews were identified; conditions included chronic heart failure (CHF; 12 reviews), diabetes mellitus (DM; seven reviews), chronic obstructive pulmonary disease (COPD; seven reviews) and asthma (five reviews). The median number of AMSTAR checklist items met was five: few reviewers searched for unpublished literature or described the primary studies and interventions in detail. Most reviews covered comprehensive services across the care continuum or standardization of care through inter-professional teams, but organizational culture, governance structure or financial management were rarely assessed. A majority of reviews found beneficial effects of integration, including reduced hospital admissions and re-admissions (in CHF and DM), improved adherence to treatment guidelines (DM, COPD and asthma) or quality of life (DM). Few reviews showed reductions in costs. Systematic reviews of integrated care programmes were of mixed quality, assessed only some components of integration of care, and showed consistent benefits for some outcomes but not others. © The Author 2014. Published by Oxford University Press in association with the International Society for Quality in Health Care.
Crescentini, Marco; Thei, Frederico; Bennati, Marco; Saha, Shimul; de Planque, Maurits R R; Morgan, Hywel; Tartagni, Marco
2015-06-01
Lipid bilayer membrane (BLM) arrays are required for high throughput analysis, for example drug screening or advanced DNA sequencing. Complex microfluidic devices are being developed but these are restricted in terms of array size and structure or have integrated electronic sensing with limited noise performance. We present a compact and scalable multichannel electrophysiology platform based on a hybrid approach that combines integrated state-of-the-art microelectronics with low-cost disposable fluidics providing a platform for high-quality parallel single ion channel recording. Specifically, we have developed a new integrated circuit amplifier based on a novel noise cancellation scheme that eliminates flicker noise derived from devices under test and amplifiers. The system is demonstrated through the simultaneous recording of ion channel activity from eight bilayer membranes. The platform is scalable and could be extended to much larger array sizes, limited only by electronic data decimation and communication capabilities.
NASA Astrophysics Data System (ADS)
Bézard, P.; Chevalier, X.; Legrain, A.; Navarro, C.; Nicolet, C.; Fleury, G.; Cayrefourcq, I.; Tiron, R.; Zelsmann, M.
2018-03-01
In this work, we present our recent achievements on the integration and transfer etching of a novel silicon-containing high-χ block copolymer for lines/spaces applications. Developed carbo-silane BCPs are synthesized under industrial conditions and present periodicities as low as 14 nm. A full directed self-assembly by graphoepitaxy process is shown using standard photolithography stacks and all processes are performed on 300 mm wafer compatible tools. Specific plasma processes are developed to isolate perpendicular lamellae and sub-12 nm features are finally transferred into silicon substrates. The quality of the final BCP hard mask (CDU, LWR, LER) are also investigated. Finally, thanks to the development of dedicated neutral layers and top-coats allowing perpendicular orientations, it was possible to investigate plasma etching experiments on full-sheets at 7 nm resolution, opening the way to the integration of these polymers in chemoepitaxy stacks.
Advanced GPR imaging of sedimentary features: integrated attribute analysis applied to sand dunes
NASA Astrophysics Data System (ADS)
Zhao, Wenke; Forte, Emanuele; Fontolan, Giorgio; Pipan, Michele
2018-04-01
We evaluate the applicability and the effectiveness of integrated GPR attribute analysis to image the internal sedimentary features of the Piscinas Dunes, SW Sardinia, Italy. The main objective is to explore the limits of GPR techniques to study sediment-bodies geometry and to provide a non-invasive high-resolution characterization of the different subsurface domains of dune architecture. On such purpose, we exploit the high-quality Piscinas data-set to extract and test different attributes of the GPR trace. Composite displays of multi-attributes related to amplitude, frequency, similarity and textural features are displayed with overlays and RGB mixed models. A multi-attribute comparative analysis is used to characterize different radar facies to better understand the characteristics of internal reflection patterns. The results demonstrate that the proposed integrated GPR attribute analysis can provide enhanced information about the spatial distribution of sediment bodies, allowing an enhanced and more constrained data interpretation.
NASA Astrophysics Data System (ADS)
Scaduto, David A.; Lubinsky, Anthony R.; Rowlands, John A.; Kenmotsu, Hidenori; Nishimoto, Norihito; Nishino, Takeshi; Tanioka, Kenkichi; Zhao, Wei
2014-03-01
We have previously proposed SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout), a novel detector concept with potentially superior spatial resolution and low-dose performance compared with existing flat-panel imagers. The detector comprises a scintillator that is optically coupled to an amorphous selenium photoconductor operated with avalanche gain, known as high-gain avalanche rushing photoconductor (HARP). High resolution electron beam readout is achieved using a field emitter array (FEA). This combination of avalanche gain, allowing for very low-dose imaging, and electron emitter readout, providing high spatial resolution, offers potentially superior image quality compared with existing flat-panel imagers, with specific applications to fluoroscopy and breast imaging. Through the present collaboration, a prototype HARP sensor with integrated electrostatic focusing and nano- Spindt FEA readout technology has been fabricated. The integrated electron-optic focusing approach is more suitable for fabricating large-area detectors. We investigate the dependence of spatial resolution on sensor structure and operating conditions, and compare the performance of electrostatic focusing with previous technologies. Our results show a clear dependence of spatial resolution on electrostatic focusing potential, with performance approaching that of the previous design with external mesh-electrode. Further, temporal performance (lag) of the detector is evaluated and the results show that the integrated electrostatic focusing design exhibits comparable or better performance compared with the mesh-electrode design. This study represents the first technical evaluation and characterization of the SAPHIRE concept with integrated electrostatic focusing.
Miller, Katherine J; Couchie, Carol; Ehman, William; Graves, Lisa; Grzybowski, Stefan; Medves, Jennifer
2012-10-01
To provide an overview of current information on issues in maternity care relevant to rural populations. Medline was searched for articles published in English from 1995 to 2012 about rural maternity care. Relevant publications and position papers from appropriate organizations were also reviewed. This information will help obstetrical care providers in rural areas to continue providing quality care for women in their communities. Recommendations 1. Women who reside in rural and remote communities in Canada should receive high-quality maternity care as close to home as possible. 2. The provision of rural maternity care must be collaborative, woman- and family-centred, culturally sensitive, and respectful. 3. Rural maternity care services should be supported through active policies aligned with these recommendations. 4. While local access to surgical and anaesthetic services is desirable, there is evidence that good outcomes can be sustained within an integrated perinatal care system without local access to operative delivery. There is evidence that the outcomes are better when women do not have to travel far from their communities. Access to an integrated perinatal care system should be provided for all women. 5. The social and emotional needs of rural women must be considered in service planning. Women who are required to leave their communities to give birth should be supported both financially and emotionally. 6. Innovative interprofessional models should be implemented as part of the solution for high-quality, collaborative, and integrated care for rural and remote women. 7. Registered nurses are essential to the provision of high-quality rural maternity care throughout pregnancy, birth, and the postpartum period. Maternity nursing skills should be recognized as a fundamental part of generalist rural nursing skills. 8. Remuneration for maternity care providers should reflect the unique challenges and increased professional responsibility faced by providers in rural settings. Remuneration models should facilitate interprofessional collaboration. 9. Practitioners skilled in neonatal resuscitation and newborn care are essential to rural maternity care. 10. Training of rural maternity health care providers should include collaborative practice as well as the necessary clinical skills and competencies. Sites must be developed and supported to train midwives, nurses, and physicians and provide them with the skills necessary for rural maternity care. Training in rural and northern settings must be supported. 11. Generalist skills in maternity care, surgery, and anaesthesia are valued and should be supported in training programs in family medicine, surgery, and anaesthesia as well as nursing and midwifery. 12. All physicians and nurses should be exposed to maternity care in their training, and basic competencies should be met. 13. Quality improvement and outcome monitoring should be integral to all maternity care systems. 14. Support must be provided for ongoing, collaborative, interprofessional, and locally provided continuing education and patient safety programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casar, B; Carot, I Mendez; Peterlin, P
2016-06-15
Purpose: Aim of the multi-centre study was to analyse beam hardening effect of the Integral Quality Monitor (IQM) for high energy photon beams used in radiotherapy with linear accelerators. Generic values for attenuation coefficient k(IQM) of IQM system were additionally investigated. Methods: Beam hardening effect of the IQM system was studied for a set of standard nominal photon energies (6 MV–18 MV) and two flattening filter free (FFF) energies (6 MV FFF and 10 MV FFF). PDD curves were measured and analysed for various square radiation fields, with and without IQM in place. Differences between PDD curves were statistically analysedmore » through comparison of respective PDD-20,10 values. Attenuation coefficients k(IQM) were determined for the same range of photon energies. Results: Statistically significant differences in beam qualities for all evaluated high energy photon beams were found, comparing PDD-20,10 values derived from PDD curves with and without IQM in place. Significance of beam hardening effect was statistically proven with high confidence (p < 0,01) for all analysed photon beams except for 15 MV (p = 0,078), although relative differences in beam qualities were minimal, ranging from 0,1 % to 0,5 %. Attenuation of the IQM system showed negligible dependence on radiation field size. However, clinically important dependence of kIQM versus TPRs20,10 was found: 0,941 for 6 MV photon beams, to 0,959 for 18 MV photon beams, with highest uncertainty below 0,006. k(IQM) versus TPRs were tabulated and polynomial equation for the determination of k(IQM) is suggested for clinical use. Conclusion: There was no clinically relevant beam hardening, when IQM system was on linear accelerators. Consequently, no additional commissioning is needed for the IQM system regarding the determination of beam qualities. Generic values for k(IQM) are proposed and can be used as tray factors for complete range of examined photon beam energies.« less
Implementing a user-driven online quality improvement toolkit for cancer care.
Luck, Jeff; York, Laura S; Bowman, Candice; Gale, Randall C; Smith, Nina; Asch, Steven M
2015-05-01
Peer-to-peer collaboration within integrated health systems requires a mechanism for sharing quality improvement lessons. The Veterans Health Administration (VA) developed online compendia of tools linked to specific cancer quality indicators. We evaluated awareness and use of the toolkits, variation across facilities, impact of social marketing, and factors influencing toolkit use. A diffusion of innovations conceptual framework guided the collection of user activity data from the Toolkit Series SharePoint site and an online survey of potential Lung Cancer Care Toolkit users. The VA Toolkit Series site had 5,088 unique visitors in its first 22 months; 5% of users accounted for 40% of page views. Social marketing communications were correlated with site usage. Of survey respondents (n = 355), 54% had visited the site, of whom 24% downloaded at least one tool. Respondents' awareness of the lung cancer quality performance of their facility, and facility participation in quality improvement collaboratives, were positively associated with Toolkit Series site use. Facility-level lung cancer tool implementation varied widely across tool types. The VA Toolkit Series achieved widespread use and a high degree of user engagement, although use varied widely across facilities. The most active users were aware of and active in cancer care quality improvement. Toolkit use seemed to be reinforced by other quality improvement activities. A combination of user-driven tool creation and centralized toolkit development seemed to be effective for leveraging health information technology to spread disease-specific quality improvement tools within an integrated health care system. Copyright © 2015 by American Society of Clinical Oncology.
The Complexity of Health Service Integration: A Review of Reviews.
Heyeres, Marion; McCalman, Janya; Tsey, Komla; Kinchin, Irina
2016-01-01
The aim of health service integration is to provide a sustainable and integrated health system that better meets the needs of the end user. Yet, definitions of health service integration, methods for integrating health services, and expected outcomes are varied. This review was commissioned by Queensland Health, the government department responsible for health service delivery in Queensland, Australia, to inform efforts to integrate their mental health services. This review reports on the characteristics, reported outcomes, and design quality of studies included in systematic reviews of health service integration research. The review was developed by systematically searching nine electronic databases to find peer-reviewed Australian and international systematic reviews with a focus on health service integration. Reviews were included if they were in the English language and published between 2000 and 2015. A standardized assessment tool was used to analyze the study design quality of included reviews. Data relating to the integration types, methods, and reported outcomes of integration were synthesized. Seventeen publications met the inclusion criteria. Eleven (65%) reviews were published during the past 5 years, which may indicate a trend for increased awareness of the need for service integration. The majority of reviews were published by researchers in the UK (8/47%), USA (3/18%), and Australia (3/18%). Included reviews focused on a variety of integration types, including integrated care pathways, governance models, integration of interventions, collaborative/integrated care models, and integration of different types of health care. Most (53%) of the reviews reported on the cost-effectiveness of service integration, e.g., positive results, no effect, or inconclusive. Only one of the reviews reported on the importance of consumer involvement. The overall design of 70% of the reviews was high, 18% medium, and 12% low. There is no "one size fits all" approach to health service integration. Instead, this literature review highlighted the complexity of service integration, which in most primary studies involved a range of strategies. Rigorous assessments of cost-effectiveness and reporting on consumer involvement are required in future research.
Overview of Power Quality and Integrated Testing at JSC
NASA Technical Reports Server (NTRS)
Davies, Francis
2018-01-01
This presentation describes the basic philosophy behind integrated testing and partially integrated testing. It lists some well known errors in space systems that were or could have been caught during integrated testing. Two examples of integrated testing at the Johnson Space Center (JSC) are mentioned, and then an overview of two test facilities that do power testing (partially integrated testing) at JSC are presented, with information on the capabilities of each. Finally a list of three projects that has problems caught during power quality or Electromagnetic Interference (EMI) testing is presented.
ERIC Educational Resources Information Center
Chua, Junnaina Husin; Jamil, Hazri
2014-01-01
Technological Knowledge is directly related to productivity, enhanced performance and service quality. Technology integration in the Technical and Vocational Education and Training (TVET) curriculum is expected due to high application of technical knowledge and technology applications. TPACK is a professional knowledge framework that gives…
Model-Driven Development of Interactive Multimedia Applications with MML
NASA Astrophysics Data System (ADS)
Pleuss, Andreas; Hussmann, Heinrich
There is an increasing demand for high-quality interactive applications which combine complex application logic with a sophisticated user interface, making use of individual media objects like graphics, animations, 3D graphics, audio or video. Their development is still challenging as it requires the integration of software design, user interface design, and media design.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-20
... the treatment for project participants and, where feasible, for a comparison group of non... in the project (control group). The effect of the project is the average difference in outcomes between the treatment and control groups. Integrating means (i) encouraging the use of high-quality arts...
M. Anisul Islam; Kent G. Apostol; Douglass F. Jacobs; R. Kasten Dumroese
2009-01-01
Fertilization is an integral component of nursery culture for production of high quality seedlings for afforestation and reforestation because it can enhance plant growth, nutrient storage reserves, and resistance to biotic and abiotic stresses (Landis, 1985). While fertilizer is conventionally applied during spring and summer in accordance with the...
Ecosystem processes at the watershed scale: mapping and modeling ecohydrological controls
Lawrence E. Band; T. Hwang; T.C. Hales; James Vose; Chelcy Ford
2012-01-01
Mountain watersheds are sources of a set of valuable ecosystem services as well as potential hazards. The former include high quality freshwater, carbon sequestration, nutrient retention, and biodiversity, whereas the latter include flash floods, landslides and forest fires. Each of these ecosystem services and hazards represents different elements of the integrated...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... investor confidence and market integrity, the Exchange designed the MQP Program to be highly transparent...), respectively. Background The proposed Market Quality Program is a voluntary program designed to promote market... obligations of listed Companies. The Rule 5300, 5400, and 5500 Series contain the specific quantitative...
Trustees: Allies in Academic Integrity
ERIC Educational Resources Information Center
Martin, Jerry L.
2003-01-01
According to this author, it may not be the first instinct of the typical professor to ask trustees to become involved in issues of academic quality. Most professors' instincts were formed in a different time and they may have forgotten how much the academic world has changed. Professors used to defend high academic standards, the liberal arts,…
Understanding and integrating native knowledge to determine and identify high quality ash resources
Suzanne Greenlaw; Marla R. Emery; Robin W. Kimmerer; Michael. Bridgen
2010-01-01
Black ash (Fraxinus nigra) is spiritually, economically, and culturally connected to Native American tribes throughout its range. Considered a cultural keystone species, black ash can be pounded and split along its growth rings to produce exceptionally strong and pliable strips to weave into baskets. Black ash harvesters and basketmakers (...
Computer Integrated Hardwood Processing
Luis G. Occeña; Daniel L. Schmoldt
1997-01-01
The planning of how the hardwood log can be sawn to improve recovery of high-value lumber has always been hampered by the limited information provided by external defects, and whatever internal defects are eventually revealed on the cut log faces by the sawing pattern. With expanded export and domestic markets, low-quality logs, increased competition from non-wood...
Family Literacy and Global Literature: Parents as Partners in the Common Core
ERIC Educational Resources Information Center
Truesdell, Kim S.; del Prado Hill, Pixita
2015-01-01
This "Teaching Tip" will explain an initiative, Global Book Hour, that engages families in a global literature read aloud. GBH integrates social studies, the visual and performing arts, healthy eating, and vocabulary development as children travel the world through high quality global children's literature. The program is a…
Integration of Video-Based Demonstrations to Prepare Students for the Organic Chemistry Laboratory
ERIC Educational Resources Information Center
Nadelson, Louis S.; Scaggs, Jonathan; Sheffield, Colin; McDougal, Owen M.
2015-01-01
Consistent, high-quality introductions to organic chemistry laboratory techniques effectively and efficiently support student learning in the organic chemistry laboratory. In this work, we developed and deployed a series of instructional videos to communicate core laboratory techniques and concepts. Using a quasi-experimental design, we tested the…
Historically, water quality assessments in the United States primarily focused on water chemistry assays at or near discharge sources. As it has become clear that waters also can be highly impaired from dispersed (i.e., non-point source) chemicals and non-chemical impacts, direc...
ERIC Educational Resources Information Center
Roulston, Audrey; Cleak, Helen; Vreugdenhil, Anthea
2018-01-01
Practice learning is integral to the curriculum for qualifying social work students. Accreditation standards require regular student supervision and exposure to specific learning activities. Most agencies offer high-quality placements, but organizational cutbacks may affect supervision and restrict the development of competence and professional…
Beyond meaningful use: getting meaningful value from IT.
Fortin, Jason; Zywiak, Walt
2010-02-01
The HITECH provisions of ARRA include financial incentives for providers to demonstrate meaningful use of certified EHR technology. However, to maximize the value of IT under new payment models, provider organizations will need to go beyond meaningful use criteria in three key areas: Delivering high-quality care. Ensuring coordinated care. Integrating financial systems.
USDA-ARS?s Scientific Manuscript database
The objective of this research was to develop an integrated process to produce biogas and high-quality particleboard using saline creeping wild ryegrass (CWR), Leymus triticoides through anaerobic digestion (AD). Besides producing biogas, AD also serves as a pretreatment method to remove the wax la...
Increased stormwater flows are a direct result of urbanization and the consequent increase in the proportion of land area under impervious surface. Due to its contribution to abnormally high stream flows and its role as a carrier of pollutants that degrade water quality, excess s...
Redesigning Continuing Education in the Health Professions
ERIC Educational Resources Information Center
National Academies Press, 2010
2010-01-01
Today in the United States, the professional health workforce is not consistently prepared to provide high quality health care and assure patient safety, even as the nation spends more per capita on health care than any other country. The absence of a comprehensive and well-integrated system of continuing education (CE) in the health professions…
Beyond Superheroes and Sidekicks: Empowerment, Efficacy, and Education in Community Partnerships
ERIC Educational Resources Information Center
Stanlick, Sarah; Sell, Marla
2016-01-01
To support the work of service-learning and community engagement (SLCE) being done in a high-quality, sustainable way, ("Combining Service and Learning: A Resource Book for Community and Public Service"), Kendall offered three Principles of Good Practice: (1) integrating service-learning programs into the central mission and goals of the…
NASA Astrophysics Data System (ADS)
Guo, Pengfei; Shen, Xia; Zhang, Baolong; Sun, Haibin; Zou, Zhijun; Yang, Wenchao; Gong, Ke; Luo, Yongsong
2018-05-01
A simple two-step CVD method is developed to realize the growth of high-quality tin-catalyzed CdSSe alloy nanowires. Microstructural characterizations demonstrate that these wires are high-quality crystalline nanostructures. Local photoluminescence investigation of these nanostructures shows a typical band edge emission at 656 nm with a full-width at half-maximum of 22.3 nm. Optical waveguide measurement along an individual nanowire indicates that the output signal of the guided light has a rapid linear decrease accompanied with maximum red-shift about 109 meV after the transmission of 102 μm. This obvious red-shift is caused by the intensive band-tail absorption during the optical transmission process. Moreover, optically pumped nanolasers are successfully realized at room temperature based on these unique wires, further demonstrating the achievement of stimulated emission from spontaneous emission, promoted by the pump power intensity. This work may find a simple route to the manufacture of superior nanowires for applications in waveguide and integrated photonic devices.
Guo, Pengfei; Shen, Xia; Zhang, Baolong; Sun, Haibin; Zou, Zhijun; Yang, Wenchao; Gong, Ke; Luo, Yongsong
2018-05-04
A simple two-step CVD method is developed to realize the growth of high-quality tin-catalyzed CdSSe alloy nanowires. Microstructural characterizations demonstrate that these wires are high-quality crystalline nanostructures. Local photoluminescence investigation of these nanostructures shows a typical band edge emission at 656 nm with a full-width at half-maximum of 22.3 nm. Optical waveguide measurement along an individual nanowire indicates that the output signal of the guided light has a rapid linear decrease accompanied with maximum red-shift about 109 meV after the transmission of 102 μm. This obvious red-shift is caused by the intensive band-tail absorption during the optical transmission process. Moreover, optically pumped nanolasers are successfully realized at room temperature based on these unique wires, further demonstrating the achievement of stimulated emission from spontaneous emission, promoted by the pump power intensity. This work may find a simple route to the manufacture of superior nanowires for applications in waveguide and integrated photonic devices.
Graphene growth on Ge(100)/Si(100) substrates by CVD method.
Pasternak, Iwona; Wesolowski, Marek; Jozwik, Iwona; Lukosius, Mindaugas; Lupina, Grzegorz; Dabrowski, Pawel; Baranowski, Jacek M; Strupinski, Wlodek
2016-02-22
The successful integration of graphene into microelectronic devices is strongly dependent on the availability of direct deposition processes, which can provide uniform, large area and high quality graphene on nonmetallic substrates. As of today the dominant technology is based on Si and obtaining graphene with Si is treated as the most advantageous solution. However, the formation of carbide during the growth process makes manufacturing graphene on Si wafers extremely challenging. To overcome these difficulties and reach the set goals, we proposed growth of high quality graphene layers by the CVD method on Ge(100)/Si(100) wafers. In addition, a stochastic model was applied in order to describe the graphene growth process on the Ge(100)/Si(100) substrate and to determine the direction of further processes. As a result, high quality graphene was grown, which was proved by Raman spectroscopy results, showing uniform monolayer films with FWHM of the 2D band of 32 cm(-1).
Report Central: quality reporting tool in an electronic health record.
Jung, Eunice; Li, Qi; Mangalampalli, Anil; Greim, Julie; Eskin, Michael S; Housman, Dan; Isikoff, Jeremy; Abend, Aaron H; Middleton, Blackford; Einbinder, Jonathan S
2006-01-01
Quality reporting tools, integrated with ambulatory electronic health records, can help clinicians and administrators understand performance, manage populations, and improve quality. Report Central is a secure web report delivery tool built on Crystal Reports XItrade mark and ASP.NET technologies. Pilot evaluation of Report Central indicates that clinicians prefer a quality reporting tool that is integrated with our home-grown EHR to support clinical workflow.
Childs, Kevin L; Konganti, Kranti; Buell, C Robin
2012-01-01
Major feedstock sources for future biofuel production are likely to be high biomass producing plant species such as poplar, pine, switchgrass, sorghum and maize. One active area of research in these species is genome-enabled improvement of lignocellulosic biofuel feedstock quality and yield. To facilitate genomic-based investigations in these species, we developed the Biofuel Feedstock Genomic Resource (BFGR), a database and web-portal that provides high-quality, uniform and integrated functional annotation of gene and transcript assembly sequences from species of interest to lignocellulosic biofuel feedstock researchers. The BFGR includes sequence data from 54 species and permits researchers to view, analyze and obtain annotation at the gene, transcript, protein and genome level. Annotation of biochemical pathways permits the identification of key genes and transcripts central to the improvement of lignocellulosic properties in these species. The integrated nature of the BFGR in terms of annotation methods, orthologous/paralogous relationships and linkage to seven species with complete genome sequences allows comparative analyses for biofuel feedstock species with limited sequence resources. Database URL: http://bfgr.plantbiology.msu.edu.
Quality, efficiency, and organizational structure.
Sterns, Jay B
2007-01-01
Physicians and their practice patterns are the largest single determinant of the level of aggregate national health care expenditures. Integrated delivery systems (organizations linking a multispecialty physician groups and acute care hospitals) appear to be more efficient than other organizational structures while providing better clinical outcomes. To determine whether a subset of hospitals was more or less efficient than the national average, we relied on data from the Dartmouth Atlas Project, which included data from 4,346 hospitals. The analysis was restricted to patients who had one or more of 12 chronic illnesses associated with a high probability of death, and the number of hospitals identified as our control group was 14, represented by 13 organizations. Based on the preliminary data, physicians operating in a multispecialty group appear to use less physician resources to care for their patients and admit less often to a hospital, thereby reducing health care expenditures. As the federal government seeks to foster more efficient health care delivery and better outcomes, it may look to the physician-led integrated delivery network as an example of an efficient and high quality model.
Optimizing point-of-care testing in clinical systems management.
Kost, G J
1998-01-01
The goal of improving medical and economic outcomes calls for leadership based on fundamental principles. The manager of clinical systems works collaboratively within the acute care center to optimize point-of-care testing through systematic approaches such as integrative strategies, algorithms, and performance maps. These approaches are effective and efficacious for critically ill patients. Optimizing point-of-care testing throughout the entire health-care system is inherently more difficult. There is potential to achieve high-quality testing, integrated disease management, and equitable health-care delivery. Despite rapid change and economic uncertainty, a macro-strategic, information-integrated, feedback-systems, outcomes-oriented approach is timely, challenging, effective, and uplifting to the creative human spirit.
"A manager in the minds of doctors:" a comparison of new modes of control in European hospitals.
Kuhlmann, Ellen; Burau, Viola; Correia, Tiago; Lewandowski, Roman; Lionis, Christos; Noordegraaf, Mirko; Repullo, Jose
2013-07-02
Hospital governance increasingly combines management and professional self-governance. This article maps the new emergent modes of control in a comparative perspective and aims to better understand the relationship between medicine and management as hybrid and context-dependent. Theoretically, we critically review approaches into the managerialism-professionalism relationship; methodologically, we expand cross-country comparison towards the meso-level of organisations; and empirically, the focus is on processes and actors in a range of European hospitals. The research is explorative and was carried out as part of the FP7 COST action IS0903 Medicine and Management, Working Group 2. Comprising seven European countries, the focus is on doctors and public hospitals. We use a comparative case study design that primarily draws on expert information and document analysis as well as other secondary sources. The findings reveal that managerial control is not simply an external force but increasingly integrated in medical professionalism. These processes of change are relevant in all countries but shaped by organisational settings, and therefore create different patterns of control: (1) 'integrated' control with high levels of coordination and coherent patterns for cost and quality controls; (2) 'partly integrated' control with diversity of coordination on hospital and department level and between cost and quality controls; and (3) 'fragmented' control with limited coordination and gaps between quality control more strongly dominated by medicine, and cost control by management. Our comparison highlights how organisations matter and brings the crucial relevance of 'coordination' of medicine and management across the levels (hospital/department) and the substance (cost/quality-safety) of control into perspective. Consequently, coordination may serve as a taxonomy of emergent modes of control, thus bringing new directions for cost-efficient and quality-effective hospital governance into perspective.
Using regression methods to estimate stream phosphorus loads at the Illinois River, Arkansas
Haggard, B.E.; Soerens, T.S.; Green, W.R.; Richards, R.P.
2003-01-01
The development of total maximum daily loads (TMDLs) requires evaluating existing constituent loads in streams. Accurate estimates of constituent loads are needed to calibrate watershed and reservoir models for TMDL development. The best approach to estimate constituent loads is high frequency sampling, particularly during storm events, and mass integration of constituents passing a point in a stream. Most often, resources are limited and discrete water quality samples are collected on fixed intervals and sometimes supplemented with directed sampling during storm events. When resources are limited, mass integration is not an accurate means to determine constituent loads and other load estimation techniques such as regression models are used. The objective of this work was to determine a minimum number of water-quality samples needed to provide constituent concentration data adequate to estimate constituent loads at a large stream. Twenty sets of water quality samples with and without supplemental storm samples were randomly selected at various fixed intervals from a database at the Illinois River, northwest Arkansas. The random sets were used to estimate total phosphorus (TP) loads using regression models. The regression-based annual TP loads were compared to the integrated annual TP load estimated using all the data. At a minimum, monthly sampling plus supplemental storm samples (six samples per year) was needed to produce a root mean square error of less than 15%. Water quality samples should be collected at least semi-monthly (every 15 days) in studies less than two years if seasonal time factors are to be used in the regression models. Annual TP loads estimated from independently collected discrete water quality samples further demonstrated the utility of using regression models to estimate annual TP loads in this stream system.
NASA Technical Reports Server (NTRS)
House, G.
1980-01-01
Methods are defined for implementing quality assurance policy and requirements for life sciences laboratory equipment, experimental hardware, integration and test support equipment, and integrated payloads.