NASA Astrophysics Data System (ADS)
Chen, Y.; Han, D.
2017-12-01
Water system is an essential component in a smart city for its sustainability and resilience. The freshness and beauty of the water body would please people as well as benefit the local aquatic ecosystems. Water quality monitoring approach has evolved from the manual lab-based monitoring approach to the manual in-situ monitoring approach, and finally to the latest wireless-sensor-network (WSN) based solutions in recent decades. The development of the in-situ water quality sensors enable humans to collect high-frequency and real-time water quality data. This poster aims to explore the advantages of the high-frequency water quality data over the low-frequency data collected manually. The data is collected by a remote real-time high-frequency water quality monitor system based on the cutting edge smart city infrastructure in Bristol - `Bristol Is Open'. The water quality of Bristol Floating Harbour is monitored which is the focal area of Bristol with new buildings and features redeveloped in the past decades. This poster will first briefly introduce the water quality monitoring system, followed by the analysis of the advantages of the sub-hourly water quality data. Thus, the suggestion on the monitoring frequency will be given.
High quality data: An evaluation of AIM data quality and data quality procedures
USDA-ARS?s Scientific Manuscript database
The goal of every monitoring program is to collect high-quality data which can then be used to provide information to decision makers. The Bureau of Land Management (BLM) Assessment, Inventory, and Monitoring (AIM) program is one such data set which provides rangeland status, condition, and trend in...
Quality-control issues on high-resolution diagnostic monitors.
Parr, L F; Anderson, A L; Glennon, B K; Fetherston, P
2001-06-01
Previous literature indicates a need for more data collection in the area of quality control of high-resolution diagnostic monitors. Throughout acceptance testing, which began in June 2000, stability of monitor calibration was analyzed. Although image quality on all monitors was found to be acceptable upon initial acceptance testing using VeriLUM software by Image Smiths, Inc (Germantown, MD), it was determined to be unacceptable during the clinical phase of acceptance testing. High-resolution monitors were evaluated for quality assurance on a weekly basis from installation through acceptance testing and beyond. During clinical utilization determination (CUD), monitor calibration was identified as a problem and the manufacturer returned and recalibrated all workstations. From that time through final acceptance testing, high-resolution monitor calibration and monitor failure rate remained a problem. The monitor vendor then returned to the site to address these areas. Monitor defocus was still noticeable and calibration checks were increased to three times per week. White and black level drift on medium-resolution monitors had been attributed to raster size settings. Measurements of white and black level at several different size settings were taken to determine the effect of size on white and black level settings. Black level remained steady with size change. White level appeared to increase by 2.0 cd/m2 for every 0.1 inches decrease in horizontal raster size. This was determined not to be the cause of the observed brightness drift. Frequency of calibration/testing is an issue in a clinical environment. The increased frequency required at our site cannot be sustained. The medical physics division cannot provide dedicated personnel to conduct the quality-assurance testing on all monitors at this interval due to other physics commitments throughout the hospital. Monitor access is also an issue due to radiologists' need to read images. Some workstations are in use 7 AM to 11 PM daily. An appropriate monitor calibration frequency must be established during acceptance testing to ensure unacceptable drift is not masked by excessive calibration frequency. Standards for acceptable black level and white level drift also need to be determined. The monitor vendor and hospital staff agree that currently, very small printed text is an acceptable method of determining monitor blur, however, a better method of determining monitor blur is being pursued. Although monitors may show acceptable quality during initial acceptance testing, they need to show sustained quality during the clinical acceptance-testing phase. Defocus, black level, and white level are image quality concerns, which need to be evaluated during the clinical phase of acceptance testing. Image quality deficiencies can have a negative impact on patient care and raise serious medical-legal concerns. The attention to quality control required of the hospital staff needs to be realistic and not have a significant impact on radiology workflow.
D. Schirokauer; L. Geiser; A. Bytnerowicz; M. Fenn; K. Dillman
2014-01-01
Air quality and air quality related values are important resources to the National Park Service (NPS) units and Wilderness areas in northern Southeast Alaska. Air quality monitoring was prioritized as a high-priority Vital Sign at the Southeast Alaska Networkâs (SEAN) Inventory and Monitoring Programâs terrestrial scoping workshop (Derr and Fastie 2006). Air quality...
Brown, Alexandra E; Okayasu, Hiromasa; Nzioki, Michael M; Wadood, Mufti Z; Chabot-Couture, Guillaume; Quddus, Arshad; Walker, George; Sutter, Roland W
2014-11-01
Monitoring the quality of supplementary immunization activities (SIAs) is a key tool for polio eradication. Regular monitoring data, however, are often unreliable, showing high coverage levels in virtually all areas, including those with ongoing virus circulation. To address this challenge, lot quality assurance sampling (LQAS) was introduced in 2009 as an additional tool to monitor SIA quality. Now used in 8 countries, LQAS provides a number of programmatic benefits: identifying areas of weak coverage quality with statistical reliability, differentiating areas of varying coverage with greater precision, and allowing for trend analysis of campaign quality. LQAS also accommodates changes to survey format, interpretation thresholds, evaluations of sample size, and data collection through mobile phones to improve timeliness of reporting and allow for visualization of campaign quality. LQAS becomes increasingly important to address remaining gaps in SIA quality and help focus resources on high-risk areas to prevent the continued transmission of wild poliovirus. © Crown copyright 2014.
Fandakova, Yana; Sander, Myriam C; Grandy, Thomas H; Cabeza, Roberto; Werkle-Bergner, Markus; Shing, Yee Lee
2018-02-01
Older adults are more likely than younger adults to falsely recall past episodes that occurred differently or not at all. We examined whether older adults' propensity for false associative memory is related to declines in postretrieval monitoring processes and their modulation with varying memory representations. Younger (N = 20) and older adults (N = 32) studied and relearned unrelated scene-word pairs, followed by a final cued recall that was used to distribute the pairs for an associative recognition test 24 hours later. This procedure allowed individualized formation of rearranged pairs that were made up of elements of pairs that were correctly recalled in the final cued recall ("high-quality" pairs), and of pairs that were not correctly recalled ("low-quality" pairs). Both age groups falsely recognized more low-quality than high-quality rearranged pairs, with a less pronounced reduction in false alarms to high-quality pairs in older adults. In younger adults, cingulo-opercular activity was enhanced for false alarms and for low-quality correct rejections, consistent with its role in postretrieval monitoring. Older adults did not show such modulated recruitment, suggesting deficits in their selective engagement of monitoring processes given variability in the fidelity of memory representations. There were no age differences in hippocampal activity, which was higher for high-quality than low-quality correct rejections in both age groups. These results demonstrate that the engagement of cingulo-opercular monitoring mechanisms varies with memory representation quality and contributes to age-related deficits in false associative memory. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Water quality monitoring for high-priority water bodies in the Sonoran Desert network
Terry W. Sprouse; Robert M. Emanuel; Sara A. Strorrer
2005-01-01
This paper describes a network monitoring program for âhigh priorityâ water bodies in the Sonoran Desert Network of the National Park Service. Protocols were developed for monitoring selected waters for ten of the eleven parks in the Network. Park and network staff assisted in identifying potential locations of testing sites, local priorities, and how water quality...
Monitoring and modeling of microbial and biological water quality
USDA-ARS?s Scientific Manuscript database
Microbial and biological water quality informs on the health of water systems and their suitability for uses in irrigation, recreation, aquaculture, and other activities. Indicators of microbial and biological water quality demonstrate high spatial and temporal variability. Therefore, monitoring str...
Low-cost, high-density sensor network for urban emission monitoring: BEACO2N
NASA Astrophysics Data System (ADS)
Kim, J.; Shusterman, A.; Lieschke, K.; Newman, C.; Cohen, R. C.
2017-12-01
In urban environments, air quality is spatially and temporally heterogeneous as diverse emission sources create a high degree of variability even at the neighborhood scale. Conventional air quality monitoring relies on continuous measurements with limited spatial resolution or passive sampling with high-density and low temporal resolution. Either approach averages the air quality information over space or time and hinders our attempts to understand emissions, chemistry, and human exposure in the near-field of emission sources. To better capture the true spatio-temporal heterogeneity of urban conditions, we have deployed a low-cost, high-density air quality monitoring network in San Francisco Bay Area distributed at 2km horizontal spacing. The BErkeley Atmospheric CO2 Observation Network (BEACO2N) consists of approximately 50 sensor nodes, measuring CO2, CO, NO, NO2, O3, and aerosol. Here we describe field-based calibration approaches that are consistent with the low-cost strategy of the monitoring network. Observations that allow inference of emission factors and identification of specific local emission sources will also be presented.
Monitoring and predicting shrink potential and future processing quality of potato tubers
USDA-ARS?s Scientific Manuscript database
Long-term storage of potato tubers increases risks, which are often attributed to shrink and quality loss. To minimize shrink and ensure high quality tubers, producers must closely monitor the condition of the crop during storage and make necessary adjustments to management plans. Evaluation procedu...
Air quality mapping using GIS and economic evaluation of health impact for Mumbai City, India.
Kumar, Awkash; Gupta, Indrani; Brandt, Jørgen; Kumar, Rakesh; Dikshit, Anil Kumar; Patil, Rashmi S
2016-05-01
Mumbai, a highly populated city in India, has been selected for air quality mapping and assessment of health impact using monitored air quality data. Air quality monitoring networks in Mumbai are operated by National Environment Engineering Research Institute (NEERI), Maharashtra Pollution Control Board (MPCB), and Brihanmumbai Municipal Corporation (BMC). A monitoring station represents air quality at a particular location, while we need spatial variation for air quality management. Here, air quality monitored data of NEERI and BMC were spatially interpolated using various inbuilt interpolation techniques of ArcGIS. Inverse distance weighting (IDW), Kriging (spherical and Gaussian), and spline techniques have been applied for spatial interpolation for this study. The interpolated results of air pollutants sulfur dioxide (SO2), nitrogen dioxide (NO2) and suspended particulate matter (SPM) were compared with air quality data of MPCB in the same region. Comparison of results showed good agreement for predicted values using IDW and Kriging with observed data. Subsequently, health impact assessment of a ward was carried out based on total population of the ward and air quality monitored data within the ward. Finally, health cost within a ward was estimated on the basis of exposed population. This study helps to estimate the valuation of health damage due to air pollution. Operating more air quality monitoring stations for measurement of air quality is highly resource intensive in terms of time and cost. The appropriate spatial interpolation techniques can be used to estimate concentration where air quality monitoring stations are not available. Further, health impact assessment for the population of the city and estimation of economic cost of health damage due to ambient air quality can help to make rational control strategies for environmental management. The total health cost for Mumbai city for the year 2012, with a population of 12.4 million, was estimated as USD8000 million.
High-resolution remote sensing of water quality in the San Francisco Bay-Delta Estuary
Fichot, Cédric G.; Downing, Bryan D.; Bergamaschi, Brian; Windham-Myers, Lisamarie; Marvin-DiPasquale, Mark C.; Thompson, David R.; Gierach, Michelle M.
2015-01-01
The San Francisco Bay–Delta Estuary watershed is a major source of freshwater for California and a profoundly human-impacted environment. The water quality monitoring that is critical to the management of this important water resource and ecosystem relies primarily on a system of fixed water-quality monitoring stations, but the limited spatial coverage often hinders understanding. Here, we show how the latest technology in visible/near-infrared imaging spectroscopy can facilitate water quality monitoring in this highly dynamic and heterogeneous system by enabling simultaneous depictions of several water quality indicators at very high spatial resolution. The airborne portable remote imaging spectrometer (PRISM) was used to derive high-spatial-resolution (2.6 × 2.6 m) distributions of turbidity, and dissolved organic carbon (DOC) and chlorophyll-a concentrations in a wetland-influenced region of this estuary. A filter-passing methylmercury vs DOC relationship was also developed using in situ samples and enabled the high-spatial-resolution depiction of surface methylmercury concentrations in this area. The results illustrate how high-resolution imaging spectroscopy can inform management and policy development in important inland and estuarine water bodies by facilitating the detection of point- and nonpoint-source pollution, and by providing data to help assess the complex impacts of wetland restoration and climate change on water quality and ecosystem productivity.
Rowe, Barbara L.; Wilson, Stephen K.; Yager, Lisa; Wilson, Marcia H.
2013-01-01
The National Park Service (NPS) organized more than 270 parks with important natural resources into 32 ecoregional networks to conduct Inventory and Monitoring (I&M) activities for assessment of natural resources within park units. The Missouri National Recreational River (NRR) is among the 13 parks in the NPS Northern Great Plain Network (NGPN). Park managers and NGPN staff identified surface water resources as a high priority vital sign to monitor in park units. The objectives for the Missouri NRR water quality sampling design are to (1) assess the current status and long-term trends of select water quality parameters; and (2) document trends in streamflow at high-priority stream systems. Due to the large size of the Missouri River main stem, the NGPN water quality design for the Missouri NRR focuses on wadeable tributaries within the park unit. To correlate with the NGPN water quality protocols, monitoring of the Missouri NRR consists of measurement of field core parameters including dissolved oxygen, pH, specific conductance, and temperature; and streamflow. The purpose of this document is to discuss factors examined for selection of water quality monitoring on segments of the Missouri River tributaries within the Missouri NRR.Awareness of the complex history of the Missouri NRR aids in the current understanding and direction for designing a monitoring plan. Historical and current monitoring data from agencies and entities were examined to assess potential NGPN monitoring sites. In addition, the U.S. Environmental Protection Agency 303(d) list was examined for the impaired segments on tributaries to the Missouri River main stem. Because major tributaries integrate water quality effects from complex combinations of land use and environmental settings within contributing areas, a 20-mile buffer of the Missouri NRR was used to establish environmental settings that may impact the water quality of tributaries that feed the Missouri River main stem. For selection of monitoring sites, anthropogenic and natural influences to water quality were assessed for Missouri NRR tributaries. Factors that were examined include the size and contributions of tributaries within watersheds to the main stem; population density; and land use such as urban development and agricultural practices including concentrated animal feeding operations. Based on examination of these data in addition to the park’s legislation and management considerations, two sites were selected for monitoring water quality on Missouri NRR tributaries for the ice-free season (mid-May to mid-October) on a rotational basis every third year. Bow Creek at St. James was selected for water quality monitoring based on lack of long-term water quality monitoring, current recreational use, and proximity of the tributary to intense agricultural practices. In addition, land within the Bow Creek watershed is owned by the NPS. The Niobrara River at Verdel was selected for monitoring due to high use for public recreational activities, adjacent agricultural land use, and documented impairments for designated beneficial uses. Both sites will have access to real-time streamgages that will aid in a greater understanding of water quality.
An Exercise Using Lichens as Indicators of Air Quality
ERIC Educational Resources Information Center
Gottfried, Jeffry
1978-01-01
High school students learned to monitor air quality using lichens in a National Science Foundation sponsored program. In this article, monitoring procedures are discussed briefly along with means to adapt the exercise to your own area. (MA)
Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring.
Hojaiji, Hannaneh; Kalantarian, Haik; Bui, Alex A T; King, Christine E; Sarrafzadeh, Majid
2017-03-01
This paper introduces the design, calibration, and validation of a low-cost portable sensor for the real-time measurement of dust particles within the environment. The proposed design consists of low hardware cost and calibration based on temperature and humidity sensing to achieve accurate processing of airborne dust density. Using commercial particulate matter sensors, a highly accurate air quality monitoring sensor was designed and calibrated using real world variations in humidity and temperature for indoor and outdoor applications. Furthermore, to provide a low-cost secure solution for real-time data transfer and monitoring, an onboard Bluetooth module with AES data encryption protocol was implemented. The wireless sensor was tested against a Dylos DC1100 Pro Air Quality Monitor, as well as an Alphasense OPC-N2 optical air quality monitoring sensor for accuracy. The sensor was also tested for reliability by comparing the sensor to an exact copy of itself under indoor and outdoor conditions. It was found that accurate measurements under real-world humid and temperature varying and dynamically changing conditions were achievable using the proposed sensor when compared to the commercially available sensors. In addition to accurate and reliable sensing, this sensor was designed to be wearable and perform real-time data collection and transmission, making it easy to collect and analyze data for air quality monitoring and real-time feedback in remote health monitoring applications. Thus, the proposed device achieves high quality measurements at lower-cost solutions than commercially available wireless sensors for air quality.
ElMekawy, A; Hegab, H M; Pant, D; Saint, C P
2018-01-01
Globally, sustainable provision of high-quality safe water is a major challenge of the 21st century. Various chemical and biological monitoring analytics are presently utilized to guarantee the availability of high-quality water. However, these techniques still face some challenges including high costs, complex design and onsite and online limitations. The recent technology of using microbial fuel cell (MFC)-based biosensors holds outstanding potential for the rapid and real-time monitoring of water source quality. MFCs have the advantages of simplicity in design and efficiency for onsite sensing. Even though some sensing applications of MFCs were previously studied, e.g. biochemical oxygen demand sensor, recently numerous research groups around the world have presented new practical applications of this technique, which combine multidisciplinary scientific knowledge in materials science, microbiology and electrochemistry fields. This review presents the most updated research on the utilization of MFCs as potential biosensors for monitoring water quality and considers the range of potentially toxic analytes that have so far been detected using this methodology. The advantages of MFCs over established technology are also considered as well as future work required to establish their routine use. © 2017 The Society for Applied Microbiology.
Christensen, Arne; Osterberg, Lars G; Hansen, Ebba Holme
2009-08-01
Poor patient adherence is often the reason for suboptimal blood pressure control. Electronic monitoring is one method of assessing adherence. The aim was to systematically review the literature on electronic monitoring of patient adherence to self-administered oral antihypertensive medications. We searched the Pubmed, Embase, Cinahl and Psychinfo databases and websites of suppliers of electronic monitoring devices. The quality of the studies was assessed according to the quality criteria proposed by Haynes et al. Sixty-two articles were included; three met the criteria proposed by Haynes et al. and nine reported the use of electronic adherence monitoring for feedback interventions. Adherence rates were generally high, whereas average study quality was low with a recent tendency towards improved quality. One study detected investigator fraud based on electronic monitoring data. Use of electronic monitoring of patient adherence according to the quality criteria proposed by Haynes et al. has been rather limited during the past two decades. Electronic monitoring has mainly been used as a measurement tool, but it seems to have the potential to significantly improve blood pressure control as well and should be used more widely.
Virtual groups for patient WBAN monitoring in medical environments.
Ivanov, Stepan; Foley, Christopher; Balasubramaniam, Sasitharan; Botvich, Dmitri
2012-11-01
Wireless body area networks (WBAN) provide a tremendous opportunity for remote health monitoring. However, engineering WBAN health monitoring systems encounters a number of challenges including efficient WBAN monitoring information extraction, dynamically fine tuning the monitoring process to suit the quality of data, and to allow the translation of high-level requirements of medical officers to low-level sensor reconfiguration. This paper addresses these challenges, by proposing an architecture that allows virtual groups to be formed between devices of patients, nurses, and doctors in order to enable remote analysis of WBAN data. Group formation and modification is performed with respect to patients' conditions and medical officers' requirements, which could be easily adjusted through high-level policies. We also propose, a new metric called the Quality of Health Monitoring, which allows medical officers to provide feedback on the quality of WBAN data received. The WBAN data gathered are transmitted to the virtual group members through an underlying environmental sensor network. The proposed approach is evaluated through a series of simulation.
2013-01-01
Background We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. Methods Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek’s p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps ′guideline – perform - falsify – reform′. Results 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. Conclusions The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity. PMID:24074151
Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?
Chouler, Jon; Di Lorenzo, Mirella
2015-01-01
The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries. PMID:26193327
Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?
Chouler, Jon; Di Lorenzo, Mirella
2015-07-16
The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries.
In-situ quality monitoring during laser brazing
NASA Astrophysics Data System (ADS)
Ungers, Michael; Fecker, Daniel; Frank, Sascha; Donst, Dmitri; Märgner, Volker; Abels, Peter; Kaierle, Stefan
Laser brazing of zinc coated steel is a widely established manufacturing process in the automotive sector, where high quality requirements must be fulfilled. The strength, impermeablitiy and surface appearance of the joint are particularly important for judging its quality. The development of an on-line quality control system is highly desired by the industry. This paper presents recent works on the development of such a system, which consists of two cameras operating in different spectral ranges. For the evaluation of the system, seam imperfections are created artificially during experiments. Finally image processing algorithms for monitoring process parameters based the captured images are presented.
The ALICE data quality monitoring system
NASA Astrophysics Data System (ADS)
von Haller, B.; Telesca, A.; Chapeland, S.; Carena, F.; Carena, W.; Chibante Barroso, V.; Costa, F.; Denes, E.; Divià, R.; Fuchs, U.; Simonetti, G.; Soós, C.; Vande Vyvre, P.; ALICE Collaboration
2011-12-01
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.
NASA Astrophysics Data System (ADS)
Collier, A. M.; Hannigan, M.; Piedrahita, R.; Casey, J. G.; Johnston, J.; Chiang, S.
2016-12-01
The growing accessibility of low-cost air quality monitoring technologies has led to their increased usage among community-based organizations, particularly for the monitoring of pollutants dangerous to human health (e.g., hazardous air pollutants or HAPS). However, often these low-cost sensors are `off-the-shelf' and are being utilized in a manner that differs from their intended purpose - necessitating high quality calibrations. For example, VOC sensors intended for the detection of high levels of a particular compound in an industrial setting may instead be used for ambient monitoring of a group of VOCs. Academic/community partnerships can be an ideal way to improve this type of sensor quantification while providing a community with not only the opportunity to use these technologies with additional support around data quality, but also the opportunity for education around the abilities and applications of low-cost sensors. In the spring of 2016, our lab at the University of Colorado, Boulder partnered with communities in Los Angeles and Kern County to deploy low-cost air quality monitors for the purpose of quantifying methane and non-methane hydrocarbon signals in an effort to learn more about potential impacts from local sources (e.g., nearby highways and oil & gas development). The monitoring platform was developed in our lab and is capable of logging multiple gas phase species as well as some environmental parameters. The monitors include two different metal oxide VOC sensors - each with slightly different sensing capabilities. Calibration was achieved using a pre- and post-deployment field normalization to reference monitoring equipment maintained by the South Coast Air Quality Management District. Monitors were then deployed at locations throughout the community. We will present results on our efforts to quantify a total non-methane hydrocarbon signal, observations from the field data, and recommendations for academic/community partnerships formed around air quality monitoring.
Automated ground-water monitoring with Robowell: case studies and potential applications
NASA Astrophysics Data System (ADS)
Granato, Gregory E.; Smith, Kirk P.
2002-02-01
Robowell is an automated system and method for monitoring ground-water quality. Robowell meets accepted manual- sampling protocols without high labor and laboratory costs. Robowell periodically monitors and records water-quality properties and constituents in ground water by pumping a well or multilevel sampler until one or more purge criteria have been met. A record of frequent water-quality measurements from a monitoring site can indicate changes in ground-water quality and can provide a context for the interpretation of laboratory data from discrete samples. Robowell also can communicate data and system performance through a remote communication link. Remote access to ground-water data enables the user to monitor conditions and optimize manual sampling efforts. Six Robowell prototypes have successfully monitored ground-water quality during all four seasons of the year under different hydrogeologic conditions, well designs, and geochemical environments. The U.S. Geological Survey is seeking partners for research with robust and economical water-quality monitoring instruments designed to measure contaminants of concern in conjunction with the application and commercialization of the Robowell technology. Project publications and information about technology transfer opportunities are available on the Internet at URL http://ma.water.usgs.gov/automon/
Automated ground-water monitoring with robowell-Case studies and potential applications
Granato, G.E.; Smith, K.P.; ,
2001-01-01
Robowell is an automated system and method for monitoring ground-water quality. Robowell meets accepted manual-sampling protocols without high labor and laboratory costs. Robowell periodically monitors and records water-quality properties and constituents in ground water by pumping a well or multilevel sampler until one or more purge criteria have been met. A record of frequent water-quality measurements from a monitoring site can indicate changes in ground-water quality and can provide a context for the interpretation of laboratory data from discrete samples. Robowell also can communicate data and system performance through a remote communication link. Remote access to ground-water data enables the user to monitor conditions and optimize manual sampling efforts. Six Robowell prototypes have successfully monitored ground-water quality during all four seasons of the year under different hydrogeologic conditions, well designs, and geochemical environments. The U.S. Geological Survey is seeking partners for research with robust and economical water-quality monitoring instruments designed to measure contaminants of concern in conjunction with the application and commercialization of the Robowell technology. Project publications and information about technology transfer opportunities are available on the Internet at URL http://ma.water.usgs.gov/automon/.
ECONOMICS OF SAMPLE COMPOSITING AS A SCREENING TOOL IN GROUND WATER QUALITY MONITORING
Recent advances in high throughput/automated compositing with robotics/field-screening methods offer seldom-tapped opportunities for achieving cost-reduction in ground water quality monitoring programs. n economic framework is presented in this paper for the evaluation of sample ...
Use of Terrestrial Laser Scanning Technology for Long Term High Precision Deformation Monitoring
Vezočnik, Rok; Ambrožič, Tomaž; Sterle, Oskar; Bilban, Gregor; Pfeifer, Norbert; Stopar, Bojan
2009-01-01
The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable. PMID:22303152
40 CFR 52.1164 - Localized high concentrations-carbon monoxide.
Code of Federal Regulations, 2010 CFR
2010-07-01
... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...
40 CFR 52.1164 - Localized high concentrations-carbon monoxide.
Code of Federal Regulations, 2014 CFR
2014-07-01
... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...
40 CFR 52.1164 - Localized high concentrations-carbon monoxide.
Code of Federal Regulations, 2013 CFR
2013-07-01
... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...
40 CFR 52.1164 - Localized high concentrations-carbon monoxide.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...
40 CFR 52.1164 - Localized high concentrations-carbon monoxide.
Code of Federal Regulations, 2012 CFR
2012-07-01
... meteorological modeling, traffic flow monitoring, air quality monitoring and other measures necessary to... reviewing all available traffic data, physical site data and air quality and meteorological data for all... containing measures to regulate traffic and parking so as to reduce carbon monoxide emissions to achieve air...
Carvlin, Graeme N; Lugo, Humberto; Olmedo, Luis; Bejarano, Ester; Wilkie, Alexa; Meltzer, Dan; Wong, Michelle; King, Galatea; Northcross, Amanda; Jerrett, Michael; English, Paul B; Hammond, Donald; Seto, Edmund
2017-12-01
The Imperial County Community Air Monitoring Network was developed as part of a community-engaged research study to provide real-time particulate matter (PM) air quality information at a high spatial resolution in Imperial County, California. The network augmented the few existing regulatory monitors and increased monitoring near susceptible populations. Monitors were both calibrated and field validated, a key component of evaluating the quality of the data produced by the community monitoring network. This paper examines the performance of a customized version of the low-cost Dylos optical particle counter used in the community air monitors compared with both PM 2.5 and PM 10 (particulate matter with aerodynamic diameters <2.5 and <10 μm, respectively) federal equivalent method (FEM) beta-attenuation monitors (BAMs) and federal reference method (FRM) gravimetric filters at a collocation site in the study area. A conversion equation was developed that estimates particle mass concentrations from the native Dylos particle counts, taking into account relative humidity. The R 2 for converted hourly averaged Dylos mass measurements versus a PM 2.5 BAM was 0.79 and that versus a PM 10 BAM was 0.78. The performance of the conversion equation was evaluated at six other sites with collocated PM 2.5 environmental beta-attenuation monitors (EBAMs) located throughout Imperial County. The agreement of the Dylos with the EBAMs was moderate to high (R 2 = 0.35-0.81). The performance of low-cost air quality sensors in community networks is currently not well documented. This paper provides a methodology for quantifying the performance of a next-generation Dylos PM sensor used in the Imperial County Community Air Monitoring Network. This air quality network provides data at a much finer spatial and temporal resolution than has previously been possible with government monitoring efforts. Once calibrated and validated, these high-resolution data may provide more information on susceptible populations, assist in the identification of air pollution hotspots, and increase community awareness of air pollution.
Estimating TCP Packet Loss Ratio from Sampled ACK Packets
NASA Astrophysics Data System (ADS)
Yamasaki, Yasuhiro; Shimonishi, Hideyuki; Murase, Tutomu
The advent of various quality-sensitive applications has greatly changed the requirements for IP network management and made the monitoring of individual traffic flows more important. Since the processing costs of per-flow quality monitoring are high, especially in high-speed backbone links, packet sampling techniques have been attracting considerable attention. Existing sampling techniques, such as those used in Sampled NetFlow and sFlow, however, focus on the monitoring of traffic volume, and there has been little discussion of the monitoring of such quality indexes as packet loss ratio. In this paper we propose a method for estimating, from sampled packets, packet loss ratios in individual TCP sessions. It detects packet loss events by monitoring duplicate ACK events raised by each TCP receiver. Because sampling reveals only a portion of the actual packet loss, the actual packet loss ratio is estimated statistically. Simulation results show that the proposed method can estimate the TCP packet loss ratio accurately from a 10% sampling of packets.
Wilms, Heath; Mittal, Anubhav; Haydock, Matthew D; van den Heever, Marc; Devaud, Marcello; Windsor, John A
2014-04-01
To review the literature on goal directed fluid therapy and evaluate the quality of evidence for each combination of goal and monitoring method. A search of major digital databases and hand search of references was conducted. All studies assessing the clinical utility of a specific fluid therapy goal or set of goals using any monitoring method were included. Data was extracted using a pre-determined pro forma and papers were evaluated using GRADE principles to assess evidence quality. Eighty-one papers met the inclusion criteria, investigating 31 goals and 22 methods for monitoring fluid therapy in 13052 patients. In total there were 118 different goal/method combinations. Goals with high evidence quality were central venous lactate and stroke volume index. Goals with moderate quality evidence were sublingual microcirculation flow, the oxygen extraction ratio, cardiac index, cardiac output, and SVC collapsibility index. This review has highlighted the plethora of goals and methods for monitoring fluid therapy. Strikingly, there is scant high quality evidence, in particular for non-invasive G/M combinations in non-operative and non-intensive care settings. There is an urgent need to address this research gap, which will be helped by methodologies to compare utility of G/M combinations. Copyright © 2014 Elsevier Inc. All rights reserved.
Online high-speed NIR diffuse-reflectance imaging spectroscopy in food quality monitoring
NASA Astrophysics Data System (ADS)
Driver, Richard D.; Didona, Kevin
2009-05-01
The use of hyperspectral technology in the NIR for food quality monitoring is discussed. An example of the use of hyperspectral diffuse reflectance scanning and post-processing with a chemometric model shows discrimination between four pharmaceutical samples comprising Aspirin, Acetaminophen, Vitamin C and Vitamin D.
Monitoring urban air quality using a high-density network of low-cost sensor nodes in Oslo, Norway.
NASA Astrophysics Data System (ADS)
Castell, Nuria; Schneider, Philipp; Vogt, Matthias; Dauge, Franck R.; Lahoz, William; Bartonova, Alena
2017-04-01
Urban air quality represents a major public health burden and is a long-standing concern to citizens. Air pollution is associated with a range of diseases, symptoms and conditions that impair health and quality of life. In Oslo, traffic, especially exhaust from heavy-duty and private diesel vehicles and dust resuspension from studded tyres, together with wood burning in winter, are the main sources of pollution. Norway, as part of the European Economic Area, is obliged to comply with the European air quality regulations and ensure clean air. Despite this, Oslo has exceeded both the NO2 and PM10 thresholds for health protection defined in the Directive 2008/50/EC. The air quality in the Oslo area is continuously monitored in 12 compliance monitoring stations. These stations provide reliable and accurate data but their density is too low to provide a detailed spatial distribution of air quality. The emergence of low-cost nodes enables observations at high spatial resolution, providing the opportunity to enhance existing monitoring systems. However, the data generated by these nodes is significantly less accurate and precise than the data provided by reference equipment. We have conducted an evaluation of low-cost nodes to monitor NO2 and PM10, comparing the data collected with low-cost nodes against CEN (European Standardization Organization) reference analysers. During January and March 2016, a network of 24 nodes was deployed in Oslo. During January, high NO2 levels were observed for several days in a row coinciding with the formation of a thermal inversion. During March, we observed an episode with high PM10 levels due to road dust resuspension. Our results show that there is a major technical challenge associated with current commercial low-cost sensors, regarding the sensor robustness and measurement repeatability. Despite this, low-cost sensor nodes are able to reproduce the NO2 and PM10 variability. The data from the sensors was employed to generate detailed NO2 and PM10 air quality maps using a data fusion technique. This way we were able to offer localized air quality information for the city of Oslo. The outlook for commercial low-cost sensors is promising, and our results show that currently some sensors are already capable of providing coarse information about air quality, indicating if the air quality is good, moderate or if the air is heavily polluted. This type of information could be suitable for applications that aim to raise awareness, or engage the community by monitoring local air quality, as such applications do not require the same accuracy as scientific or regulatory monitoring.
Mason, Jon P.; Sebree, Sonja K.; Quinn, Thomas L.
2005-01-01
The Wind River Indian Reservation, located in parts of Fremont and Hot Springs Counties, Wyoming, has a total land area of more than 3,500 square miles. Ground water on the Wind River Indian Reservation is a valuable resource for Shoshone and Northern Arapahoe tribal members and others who live on the Reservation. There are many types of land uses on the Reservation that have the potential to affect the quality of ground-water resources. Urban areas, rural housing developments, agricultural lands, landfills, oil and natural gas fields, mining, and pipeline utility corridors all have the potential to affect ground-water quality. A cooperative study was developed between the U.S. Geological Survey and the Wind River Environmental Quality Commission to identify areas of the Reservation that have the highest potential for ground-water contamination and develop a comprehensive plan to monitor these areas. An arithmetic overlay model for the Wind River Indian Reservation was created using seven geographic information system data layers representing factors with varying potential to affect ground-water quality. The data layers used were: the National Land Cover Dataset, water well density, aquifer sensitivity, oil and natural gas fields and petroleum pipelines, sites with potential contaminant sources, sites that are known to have ground-water contamination, and National Pollutant Discharge Elimination System sites. A prioritization map for monitoring ground-water quality on the Reservation was created using the model. The prioritization map ranks the priority for monitoring ground-water quality in different areas of the Reservation as low, medium, or high. To help minimize bias in selecting sites for a monitoring well network, an automated stratified random site-selection approach was used to select 30 sites for ground-water quality monitoring within the high priority areas. In addition, the study also provided a sampling design for constituents to be monitored, sampling frequency, and a simple water-table level observation well network.
A design of wireless sensor networks for a power quality monitoring system.
Lim, Yujin; Kim, Hak-Man; Kang, Sanggil
2010-01-01
Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.
Blinova, E G; Kuchma, V R
2012-01-01
Socioeconomic transformations and the poor environment of an industrial megalopolis negatively affected quality of life and morbidity rates in students (n = 2160). Academic intensity contributed to an increase in overall morbidity and morbidity from nervous system involvement. The regional sociohygienic monitoring of high-school training conditions within the framework of the surveillance system substantiates programs to prevent worse health and life quality in high school students.
Automated water monitor system field demonstration test report. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.
1981-01-01
A system that performs water quality monitoring on-line and in real time much as it would be done in a spacecraft, was developed and demonstrated. The system has the capability to determine conformance to high effluent quality standards and to increase the potential for reclamation and reuse of water.
Using geo-targeted social media data to detect outdoor air pollution
NASA Astrophysics Data System (ADS)
Jiang, W.; Wang, Y.; Tsou, M. H.; Fu, X.
2016-06-01
Outdoor air pollution has become a more and more serious issue over recent years (He, 2014). Urban air quality is measured at air monitoring stations. Building air monitoring stations requires land, incurs costs and entails skilled technicians to maintain a station. Many countries do not have any monitoring stations and even lack any means to monitor air quality. Recent years, the social media could be used to monitor air quality dynamically (Wang, 2015; Mei, 2014). However, no studies have investigated the inter-correlations between real-space and cyberspace by examining variation in micro-blogging behaviors relative to changes in daily air quality. Thus, existing methods of monitoring AQI using micro-blogging data shows a high degree of error between real AQI and air quality as inferred from social media messages. In this paper, we introduce a new geo-targeted social media analytic method to (1) investigate the dynamic relationship between air pollution-related posts on Sina Weibo and daily AQI values; (2) apply Gradient Tree Boosting, a machine learning method, to monitor the dynamics of AQI using filtered social media messages. Our results expose the spatiotemporal relationships between social media messages and real-world environmental changes as well suggesting new ways to monitor air pollution using social media.
NASA Astrophysics Data System (ADS)
Levelt, P.; Joiner, J.; Tamminen, J.; Veefkind, P.; Bhartia, P. K.; Court, A. J.; Vlemmix, T.
2017-12-01
Keywords: emission monitoring, air quality, climate, atmospheric composition The Ozone Monitoring Instrument (OMI), launched on board of NASA's EOS-Aura spacecraft on July 15, 2004, provides unique contributions to the monitoring of the ozone layer, air quality and climate from space. With a data record of 13 years, OMI provides the longest NO2 and SO2 record from space, which is essential to understand the changes to emissions globally. The combination of urban scale resolution (13 x 24 km2 in nadir) and daily global coverage proved to be key features for the air quality community. Due to the operational Very Fast Delivery (VFD / direct readout) and Near Real Time (NRT) availability of the data, OMI also plays an important role in the early developments of operational services in the atmospheric chemistry domain. For example, OMI data is currently used operationally for improving air quality forecasts, for inverting high-resolution emission maps, the UV forecast and for volcanic plume warning systems for aviation. An overview of air quality applications, emission inventory inversions and trend analyses based on the OMI data record will be presented. An outlook will be given on the potentials of augmenting this record with the high resolution air quality measurements of TROPOMI (3,5 x 7 km2) and new satellite instrumentation entering the imaging domain, such as the TROPOLITE instrument ( 1 x 1 km2). Potential of imaging type of NO2 measurements in the the climate and air quality domain will be given, most notably on the use of high resolution NO2 measurements for pin-pointing anthropogenic CO2 emissions.
NASA Astrophysics Data System (ADS)
Faucheux, Mikaël; Fovet, Ophélie; Gruau, Gérard; Jaffrézic, Anne; Petitjean, Patrice; Gascuel-Odoux, Chantal; Ruiz, Laurent
2013-04-01
Stream water chemistry is highly variable in space and time, therefore high frequency water quality measurement methods are likely to lead to conceptual advances in the hydrological sciences. Sub-daily data on water quality improve the characterization of pollutant sources and pathways during flood events as well as during long-term periods [1]. However, real time, high frequency monitoring devices needs to be properly calibrated and validated in real streams. This study analyses data from in situ monitoring of a stream water quality. During two hydrological years (2010-11, 2011-12), a submersible UV-visible spectrometer (Scan Spectrolyser) was used for surface water quality measurement at the outlet of a headwater catchment located at Kervidy-Naizin, Western France (AgrHys long-term hydrological observatory, http://www.inra.fr/ore_agrhys/). The spectrometer is reagentless and equipped with an auto-cleaning system. It allows real time, in situ and high frequency (20 min) measurements and uses a multiwavelengt spectral (200-750 nm) for simultaneous measurement of nitrate, dissolved organic carbon (DOC) and total suspended solids (TSS). A global calibration based on a PLS (Partial Least Squares) regression is provided by the manufacturer as default configuration of the UV-visible spectrometer. We carried out a local calibration of the spectrometer based on nitrates and DOC concentrations analysed in the laboratory from daily manual sampling and sub-daily automatic sampling of flood events. TSS results are compared with 15 min turbidity records from a continuous turdidimeter (Ponsel). The results show a good correlation between laboratory data and spectrometer data both during basis flows periods and flood events. However, the local calibration gives better results than the global one. Nutrient fluxes estimates based on high and different low frequency time series (daily to monthly) are compared to discuss the implication for environmental monitoring strategies. Such monitoring methods can therefore be interesting for designing monitoring strategy of environmental observatory and provide dense time series likely to highlight patterns or trends using appropriate approaches such as spectral analysis [2]. 1. Wade, A.J. et al., HESS Discuss., 2012. 9(5), p.6458- 6506. 2. Aubert, A. et al., submitted to EGU 2013-4745 vol. 15.
NASA Astrophysics Data System (ADS)
Crawford, S. M.; Crause, Lisa; Depagne, Éric; Ilkiewicz, Krystian; Schroeder, Anja; Kuhn, Rudolph; Hettlage, Christian; Romero Colmenaro, Encarni; Kniazev, Alexei; Väisänen, Petri
2016-08-01
The High Resolution Spectrograph (HRS) on the Southern African Large Telescope (SALT) is a dual beam, fiber-fed echelle spectrograph providing high resolution capabilities to the SALT observing community. We describe the available data reduction tools and the procedures put in place for regular monitoring of the data quality from the spectrograph. Data reductions are carried out through the pyhrs package. The data characteristics and instrument stability are reported as part of the SALT Dashboard to help monitor the performance of the instrument.
Shortcomings of low-cost imaging systems for viewing computed radiographs.
Ricke, J; Hänninen, E L; Zielinski, C; Amthauer, H; Stroszczynski, C; Liebig, T; Wolf, M; Hosten, N
2000-01-01
To assess potential advantages of a new PC-based viewing tool featuring image post-processing for viewing computed radiographs on low-cost hardware (PC) with a common display card and color monitor, and to evaluate the effect of using color versus monochrome monitors. Computed radiographs of a statistical phantom were viewed on a PC, with and without post-processing (spatial frequency and contrast processing), employing a monochrome or a color monitor. Findings were compared with the viewing on a radiological Workstation and evaluated with ROC analysis. Image post-processing improved the perception of low-contrast details significantly irrespective of the monitor used. No significant difference in perception was observed between monochrome and color monitors. The review at the radiological Workstation was superior to the review done using the PC with image processing. Lower quality hardware (graphic card and monitor) used in low cost PCs negatively affects perception of low-contrast details in computed radiographs. In this situation, it is highly recommended to use spatial frequency and contrast processing. No significant quality gain has been observed for the high-end monochrome monitor compared to the color display. However, the color monitor was affected stronger by high ambient illumination.
NASA JSC water monitor system: City of Houston field demonstration
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.
1979-01-01
A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.
AIRQino, a low-cost air quality mobile platform
NASA Astrophysics Data System (ADS)
Zaldei, Alessandro; Vagnoli, Carolina; Di Lonardo, Sara; Gioli, Beniamino; Gualtieri, Giovanni; Toscano, Piero; Martelli, Francesca; Matese, Alessandro
2015-04-01
Recent air quality regulations (Directive 2008/50/EC) enforce the transition from point-based monitoring networks to new tools that must be capable of mapping and forecasting air quality on the totality of land area, and therefore the totality of citizens. This implies new technologies such as models and additional indicative measurements, are needed in addition to accurate fixed air quality monitoring stations, that until now have been taken as reference by local administrators for the enforcement of various mitigation strategies. However, due to their sporadic spatial distribution, they cannot describe the highly resolved spatial pollutant variations within cities. Integrating additional indicative measurements may provide adequate information on the spatial distribution of the ambient air quality, also allowing for a reduction of the required minimum number of fixed sampling points, whose high cost and complex maintenance still remain a crucial concern for local administrators. New low-cost and small size sensors are becoming available, that could be employed in air quality monitoring including mobile applications. However, accurate assessment of their accuracy and performance both in controlled and real monitoring conditions is crucially needed. Quantifying sensor response is a significant challenge due to the sensitivity to ambient temperature and humidity and the cross-sensitivity to others pollutant species. This study reports the development of an Arduino compatible electronic board (AIRQino) which integrates a series of low-cost metal oxide and NDIR sensors for air quality monitoring, with sensors to measure air temperature, relative humidity, noise, solar radiation and vertical acceleration. A comparative assessment was made for CO2, CO, NO2, CH4, O3, VOCs concentrations, temperature and relative humidity. A controlled climatic chamber study (-80°C / +80°C) was performed to verify temperature and humidity interference using reference gas cylinders and high quality reference sensors. The AIRQino was installed on mobile vectors such as bikes, buses and trams in the cities of Firenze and Siracusa (Italy), that send data real-time to a Web portal. By integrating a microprocessor unit it is capable of directly updating calibration coefficients to provide corrected sensor output as digital string through RS232 serial port. Results from the lab tests and the 'real world' mobile applications are presented and discussed, to assess to what extent this sensor technology might be useful for the development of portable, compact, wireless and cost-effective system for air quality monitoring in urban areas at high spatio-temporal resolution.
Monitoring changes in Greater Yellowstone Lake water quality following the 1988 wildfires
NASA Technical Reports Server (NTRS)
Lathrop, Richard G., Jr.; Vande Castle, John D.; Brass, James A.
1994-01-01
The fires that burned the Greater Yellowstone Area (GYA) during the summer of 1988 were the largest ever recorded for the region. Wildfire can have profound indirect effects on associated aquatic ecosystems by increased nutrient loading, sediment, erosion, and runoff. Satellite remote sensing and water quality sampling were used to compare pre- versus post-fire conditions in the GYA's large oliotrophic (high transparency, low productivity) lakes. Inputs of suspended sediment to Jackson Lake appear to have increased. Yellowstone Lake has not shown any discernable shift in water quality. The insights gained separately from the Landsat Thematic and NOAA Advanced Very High Resolution Radiometer (AVHRR) remote sensing systems, along with conventional in-situ sampling, can be combined into a useful water quality monitoring tool.
Tavakol, Mohsen; Dennick, Reg
2012-01-01
As great emphasis is rightly placed upon the importance of assessment to judge the quality of our future healthcare professionals, it is appropriate not only to choose the most appropriate assessment method, but to continually monitor the quality of the tests themselves, in a hope that we may continually improve the process. This article stresses the importance of quality control mechanisms in the exam cycle and briefly outlines some of the key psychometric concepts including reliability measures, factor analysis, generalisability theory and item response theory. The importance of such analyses for the standard setting procedures is emphasised. This article also accompanies two new AMEE Guides in Medical Education (Tavakol M, Dennick R. Post-examination Analysis of Objective Tests: AMEE Guide No. 54 and Tavakol M, Dennick R. 2012. Post examination analysis of objective test data: Monitoring and improving the quality of high stakes examinations: AMEE Guide No. 66) which provide the reader with practical examples of analysis and interpretation, in order to help develop valid and reliable tests.
LOVE CANAL MONITORING PROGRAM. GCA QA/QC (QUALITY ASSURANCE/QUALITY CONTROL) SUMMARY REPORT
One of the most important responsibilities of the Love Canal prime contractor was the institution and maintenance of a quality assurance program. An important objective of the quality assurance program was to alert the subcontractors to the importance of high quality work on thei...
Study of weld quality real-time monitoring system for auto-body assembly
NASA Astrophysics Data System (ADS)
Xu, Jun; Li, Yong-Bing; Chen, Guan-Long
2005-12-01
Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.
Alpaca, R I Paredes; Migliore, A; Di Rico, R; Canali, Claudia; Rota, Cristina; Trenti, T; Cariani, Elisabetta
2010-01-01
The quality of laboratory data is one of the main factors in guaranteeing efficacy of biological monitoring. To analyze the quality of laboratory data used for biological monitoring of exposed workers. A survey involving 18 companies employing 945 workers in the area of Modena, Italy, was carried out in 2008. Most of the 9 private laboratories receiving biological samples did not perform directly part or all of the laboratory assessments requested, but this was not indicated in the final report. Major problems were observed in the application of internal quality control, and only one laboratory participated in external quality assessment for blood lead measurements. Our results raise major concerns on the traceability and reliability of laboratory assessments performed for biomonitoring of exposed workers. Systematic evaluation of the quality of analytical data would be highly recommendable.
NASA Astrophysics Data System (ADS)
Jumaeri; Sulistyaningsih, T.; Alighiri, D.
2018-03-01
Salt is one of the primary ingredients that humans always need for various purposes, both for consumption and industry. The need for high-quality salt continues to increase, as long as industry growth. It must improve product quality through the development of salt production process technology. In this research, the quality monitoring of salt produced in Indonesia by evaporation of seawater on ponds lined using high-density polyethylene (HDPE) geomembrane has been studied. The manufacturing of salt carried out through the gradual precipitation principle on prepared ponds. HDPE geomembrane is used to coat evaporation ponds with viscosity 12-22°Be and crystallization ponds with a viscosity of 23°Be. The monitoring of the product is carried out in the particular periods during the salt production period. The result of control shows that the quality of salt produced in HDPE geomembrane coated salt ponds has an average NaCl content of 95.75%, so it has fulfilled with Indonesia National Standard (SNI), that is NaCl> 94.70%. The production of salt with HDPE geomembrane can improve the quality of salt product from NaCl 85.4% (conventional system) to 95.75%.
Satisfaction monitoring for quality control in campground management
Wilbur F. LaPage; Malcolm I. Bevins
1981-01-01
A 4-year study of camper satisfaction indicates that satisfaction monitoring is a useful tool for campground managers to assess their performance and achieve a high level of quality control in their service to the public. An indication of camper satisfaction with campground management is gained from a report card on which a small sample of visitors rates 14 elements of...
Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Teacher's Guide.
ERIC Educational Resources Information Center
Alberta Environment, Edmonton. Environmental Education Resources Branch.
The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…
Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Student Manual.
ERIC Educational Resources Information Center
Alberta Environment, Edmonton. Environmental Education Resources Branch.
The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…
Choices in recreational water quality monitoring: new opportunities and health risk trade-offs.
Nevers, Meredith B; Byappanahalli, Muruleedhara N; Whitman, Richard L
2013-04-02
With the recent release of new recreational water quality monitoring criteria, there are more options for regulatory agencies seeking to protect beachgoers from waterborne pathogens. Included are methods that can reduce analytical time, providing timelier estimates of water quality, but the application of these methods has not been examined at most beaches for expectation of health risk and management decisions. In this analysis, we explore health and monitoring outcomes expected at Lake Michigan beaches using protocols for indicator bacteria including culturable Escherichia coli (E. coli; EC), culturable enterococci (ENT), and enterococci as analyzed by qPCR (QENT). Correlations between method results were generally high, except at beaches with historically high concentrations of EC. The "beach action value" was exceeded most often when using EC or ENT as the target indicator; QENT exceeded the limit far less frequently. Measured water quality between years was varied. Although methods with equivalent health expectation have been established, the lack of relationship among method outcomes and annual changes in mean indicator bacteria concentrations complicates the decision-making process. The monitoring approach selected by beach managers may be a combination of available tools that maximizes timely health protection, cost efficiency, and collaboration among beach jurisdictions.
Choices in recreational water quality monitoring: new opportunities and health risk trade-offs
Nevers, Meredith B.; Byappanahalli, Muruleedhara N.; Whitman, Richard L.
2013-01-01
With the recent release of new recreational water quality monitoring criteria, there are more options for regulatory agencies seeking to protect beachgoers from waterborne pathogens. Included are methods that can reduce analytical time, providing timelier estimates of water quality, but the application of these methods has not been examined at most beaches for expectation of health risk and management decisions. In this analysis, we explore health and monitoring outcomes expected at Lake Michigan beaches using protocols for indicator bacteria including culturable Escherichia coli (E. coli; EC), culturable enterococci (ENT), and enterococci as analyzed by qPCR (QENT). Correlations between method results were generally high, except at beaches with historically high concentrations of EC. The “beach action value” was exceeded most often when using EC or ENT as the target indicator; QENT exceeded the limit far less frequently. Measured water quality between years was varied. Although methods with equivalent health expectation have been established, the lack of relationship among method outcomes and annual changes in mean indicator bacteria concentrations complicates the decision-making process. The monitoring approach selected by beach managers may be a combination of available tools that maximizes timely health protection, cost efficiency, and collaboration among beach jurisdictions.
Meaney, Peter A; Bobrow, Bentley J; Mancini, Mary E; Christenson, Jim; de Caen, Allan R; Bhanji, Farhan; Abella, Benjamin S; Kleinman, Monica E; Edelson, Dana P; Berg, Robert A; Aufderheide, Tom P; Menon, Venu; Leary, Marion
2013-07-23
The "2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care" increased the focus on methods to ensure that high-quality cardiopulmonary resuscitation (CPR) is performed in all resuscitation attempts. There are 5 critical components of high-quality CPR: minimize interruptions in chest compressions, provide compressions of adequate rate and depth, avoid leaning between compressions, and avoid excessive ventilation. Although it is clear that high-quality CPR is the primary component in influencing survival from cardiac arrest, there is considerable variation in monitoring, implementation, and quality improvement. As such, CPR quality varies widely between systems and locations. Victims often do not receive high-quality CPR because of provider ambiguity in prioritization of resuscitative efforts during an arrest. This ambiguity also impedes the development of optimal systems of care to increase survival from cardiac arrest. This consensus statement addresses the following key areas of CPR quality for the trained rescuer: metrics of CPR performance; monitoring, feedback, and integration of the patient's response to CPR; team-level logistics to ensure performance of high-quality CPR; and continuous quality improvement on provider, team, and systems levels. Clear definitions of metrics and methods to consistently deliver and improve the quality of CPR will narrow the gap between resuscitation science and the victims, both in and out of the hospital, and lay the foundation for further improvements in the future.
Meier, Frederick A; Badrick, Tony C; Sikaris, Kenneth A
2018-02-17
For 50 years, structure, process, and outcomes measures have assessed health care quality. For clinical laboratories, structural quality has generally been assessed by inspection. For assessing process, quality indicators (QIs), statistical monitors of steps in the clinical laboratory total testing, have proliferated across the globe. Connections between structural and process laboratory measures and patient outcomes, however, have rarely been demonstrated. To inform further development of clinical laboratory quality systems, we conducted a selective but worldwide review of publications on clinical laboratory quality assessment. Some QIs, like seven generic College of American Pathologists Q-Tracks monitors, have demonstrated significant process improvement; other measures have uncovered critical opportunities to improve test selection and result management. The College of Pathologists of Australasia Key Indicator Monitoring and Management System has deployed risk calculations, introduced from failure mode effects analysis, as surrogate measures for outcomes. Showing economic value from clinical laboratory testing quality is a challenge. Clinical laboratories should converge on fewer (7-14) rather than more (21-35) process monitors; monitors should cover all steps of the testing process under laboratory control and include especially high-risk specimen-quality QIs. Clinical laboratory stewardship, the combination of education interventions among clinician test orderers and report consumers with revision of test order formats and result reporting schemes, improves test ordering, but improving result reception is more difficult. Risk calculation reorders the importance of quality monitors by balancing three probabilities: defect frequency, weight of potential harm, and detection difficulty. The triple approach of (1) a more focused suite of generic consensus quality indicators, (2) more active clinical laboratory testing stewardship, and (3) integration of formal risk assessment, rather than competing with economic value, enhances it.
Analytical chemistry in water quality monitoring during manned space missions
NASA Astrophysics Data System (ADS)
Artemyeva, Anastasia A.
2016-09-01
Water quality monitoring during human spaceflights is essential. However, most of the traditional methods require sample collection with a subsequent ground analysis because of the limitations in volume, power, safety and gravity. The space missions are becoming longer-lasting; hence methods suitable for in-flight monitoring are demanded. Since 2009, water quality has been monitored in-flight with colorimetric methods allowing for detection of iodine and ionic silver. Organic compounds in water have been monitored with a second generation total organic carbon analyzer, which provides information on the amount of carbon in water at both the U.S. and Russian segments of the International Space Station since 2008. The disadvantage of this approach is the lack of compound-specific information. The recently developed methods and tools may potentially allow one to obtain in-flight a more detailed information on water quality. Namely, the microanalyzers based on potentiometric measurements were designed for online detection of chloride, potassium, nitrate ions and ammonia. The recent application of the current highly developed air quality monitoring system for water analysis was a logical step because most of the target analytes are the same in air and water. An electro-thermal vaporizer was designed, manufactured and coupled with the air quality control system. This development allowed for liberating the analytes from the aqueous matrix and further compound-specific analysis in the gas phase.
SAMIRA - SAtellite based Monitoring Initiative for Regional Air quality
NASA Astrophysics Data System (ADS)
Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nicolae, Doina; Stachlewska, Iwona; Zehner, Claus
2016-04-01
Here, we present a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellites, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. Despite considerable improvements in the past decades, Europe is still far from achieving levels of air quality that do not pose unacceptable hazards to humans and the environment. Main concerns in Europe are exceedances of particulate matter (PM), ground-level ozone, benzo(a)pyrene (BaP) and nitrogen dioxide (NO2). While overall sulfur dioxide (SO2) emissions have decreased in recent years, regional concentrations can still be high in some areas. The objectives of SAMIRA are to improve algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from SEVIRI, and to develop robust methods for deriving column- and near-surface PM maps for the study area by combining satellite AOD with information from regional models. The benefit to existing monitoring networks (in situ, models, satellite) by combining these datasets using data fusion methods will be tested for satellite-based NO2, SO2, and PM/AOD. Furthermore, SAMIRA will test and apply techniques for downscaling air quality-related EO products to a spatial resolution that is more in line with what is generally required for studying urban and regional scale air quality. This will be demonstrated for a set of study sites that include the capitals of the four countries and the highly polluted areas along the border of Poland and the Czech Republic, and the Gorj County in Romania. All data products shall undergo a quality control, i.e. robust and independent validation. The SAMIRA consortium will further work towards a pre-operational system for improved PM10 forecasts using observational (in situ and satellite) data assimilation. SAMIRA aims to maximize project benefits by liaison with national and regional environmental protection agencies and health institutions, as well as related ESA and European initiatives such as the Copernicus Atmospheric Monitoring Services (CAMS).
Miniaturized Monitors for Assessment of Exposure to Air Pollutants: A Review.
Borghi, Francesca; Spinazzè, Andrea; Rovelli, Sabrina; Campagnolo, Davide; Del Buono, Luca; Cattaneo, Andrea; Cavallo, Domenico M
2017-08-12
Air quality has a huge impact on different aspects of life quality, and for this reason, air quality monitoring is required by national and international regulations. Technical and procedural limitations of traditional fixed-site stations for monitoring or sampling of air pollutants are also well-known. Recently, a different type of miniaturized monitors has been developed. These monitors, due to their characteristics (e.g., low cost, small size, high portability) are becoming increasingly important for individual exposure assessment, especially since this kind of instrument can provide measurements at high spatial and temporal resolution, which is a notable advantage when approaching assessment of exposure to environmental contaminants. The aim of this study is indeed to provide information regarding current knowledge regarding the use of miniaturized air pollutant sensors. A systematic review was performed to identify original articles: a literature search was carried out using an appropriate query for the search of papers across three different databases, and the papers were selected using inclusion/exclusion criteria. The reviewed articles showed that miniaturized sensors are particularly versatile and could be applied in studies with different experimental designs, helping to provide a significant enhancement to exposure assessment, even though studies regarding their performance are still sparse.
Open hardware, low cost, air quality stations for monitoring ozone in coastal area
NASA Astrophysics Data System (ADS)
Lima, Marco; Donzella, Davide; Pintus, Fabio; Fedi, Adriano; Ferrari, Daniele; Massabò, Marco
2014-05-01
Ozone concentrations in urban and coastal area are a great concern for citizens and, consequently regulator. In the last 20 years the Ozone concentration is almost doubled and it has attracted the public attention because of the well know harmful impacts on human health and biosphere in general. Official monitoring networks usually comprise high precision, high accuracy observation stations, usually managed by public administrations and environmental agency; unfortunately due to their high costs of installation and maintenance, the monitoring stations are relatively sparse. This kind of monitoring networks have been recognized to be unsuitable to effectively characterize the high variability of air quality, especially in areas where pollution sources are various and often not static. We present a prototype of a low cost station for air quality monitoring, specifically developed for complementing the official monitoring stations improving the representation of air quality spatial distribution. We focused on a semi-professional product that could guarantee the highest reliability at the lowest possible cost, supported by a consistent infrastructure for data management. We test two type of Ozone sensor electrochemical and metal oxide. This work is integrated in the ACRONET Paradigm ® project: an open-hardware platform strongly oriented on environmental monitoring. All software and hardware sources will be available on the web. Thus, a computer and a small amount of work tools will be sufficient to create new monitoring networks, with the only constraint to share all the data obtained. It will so possible to create a real "sensing community". The prototype is currently able to measure ozone level, temperature and relative humidity, but soon, with the upcoming changes, it will be able also to monitor dust, carbon monoxide and nitrogen dioxide, always through the use of commercial sensors. The sensors are grouped in a compact board that interfaces with a data-logger able to transmit data to a dedicated server through a GPRS module (no ad hoc radio infrastructure needed). Due to the GPRS low latency transmission the data are transmitted in near-real time. The prototype has an independent power supply. The sensors outputs are directly compared with the measurement of the official fixed monitoring stations. We present preliminary tests of a ozone level assessment obtained without laboratory calibration during a first field campaign in Savona (Italy); the preliminary verification and test show reasonable agreement between low cost sensors and fixed monitoring station ozone level trends (low cost sensors detect gas concentration at ppb level). The preliminary results are promising for complementing the fixed official monitoring networks with low-cost sensors.
Dan Neary
2016-01-01
Forested catchments throughout the world are known for producing high quality water for human use. In the 20th Century, experimental forest catchment studies played a key role in studying the processes contributing to high water quality. The hydrologic processes investigated on these paired catchments have provided the science base for examining water quality...
Improving and monitoring air quality.
DuPont, André
2018-05-01
Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.
Use of High Resolution Mobile Monitoring Techniques to Assess Near Road Air Quality Variability
This presentation provides a description of the techniques used to develop and conduct effective mobile monitoring studies. It also provides a summary of mobile monitoring assessment studies that have been used to assess near-road concentrations and the variability of pollutant l...
Use of High Resolution Mobile Monitoring Techniques to Assess Near-Road Air Quality Variability
This presentation provides a description of the techniques used to develop and conduct effective mobile monitoring studies. It also provides a summary of mobile monitoring assessment studies that have been used to assess near-road concentrations and the variability of pollutant l...
Jennings, Larissa; Bertrand, Jane; Rech, Dino; Harvey, Steven A.; Hatzold, Karin; Samkange, Christopher A.; Omondi Aduda, Dickens S.; Fimbo, Bennett; Cherutich, Peter; Perry, Linnea; Castor, Delivette; Njeuhmeli, Emmanuel
2014-01-01
Background The rapid expansion of voluntary medical male circumcision (VMMC) has raised concerns whether health systems can deliver and sustain VMMC according to minimum quality criteria. Methods and Findings A comparative process evaluation was used to examine data from SYMMACS, the Systematic Monitoring of the Voluntary Medical Male Circumcision Scale-Up, among health facilities providing VMMC across two years of program scale-up. Site-level assessments examined the availability of guidelines, supplies and equipment, infection control, and continuity of care services. Direct observation of VMMC surgeries were used to assess care quality. Two sample tests of proportions and t-tests were used to examine differences in the percent of facilities meeting requisite preparedness standards and the mean number of directly-observed surgical tasks performed correctly. Results showed that safe, high quality VMMC can be implemented and sustained at-scale, although substantial variability was observed over time. In some settings, facility preparedness and VMMC service quality improved as the number of VMMC facilities increased. Yet, lapses in high performance and expansion of considerably deficient services were also observed. Surgical tasks had the highest quality scores, with lower performance levels in infection control, pre-operative examinations, and post-operative patient monitoring and counseling. The range of scale-up models used across countries additionally underscored the complexity of delivering high quality VMMC. Conclusions Greater efforts are needed to integrate VMMC scale-up and quality improvement processes in sub-Saharan African settings. Monitoring of service quality, not just adverse events reporting, will be essential in realizing the full health impact of VMMC for HIV prevention. PMID:24801073
Gulizia, Michele Massimo; Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian
2017-05-01
The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use.
Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Franco Gensini, Gian
2017-01-01
Abstract The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, elaboration, and presentation of the signal. Several sources of artefacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depend upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high-quality ECG signal are, therefore, of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to give scientific reference for the choice of systems able to offer high quality ECG signal acquisition, processing, and presentation suitable for clinical use. PMID:28751842
Apparatus and method for combusting low quality fuel
Brushwood, John Samuel; Pillsbury, Paul; Foote, John; Heilos, Andreas
2003-11-04
A gas turbine (12) capable of combusting a low quality gaseous fuel having a ratio of flammability limits less than 2, or a heat value below 100 BTU/SCF. A high quality fuel is burned simultaneously with the low quality fuel to eliminate instability in the combustion flame. A sensor (46) is used to monitor at least one parameter of the flame indicative of instability. A controller (50) having the sensor signal (48) as input is programmed to control the relative flow rates of the low quality and high quality fuels. When instability is detected, the flow rate of high quality fuel is automatically increased in relation to the flow rate of low quality fuel to restore stability.
Water quality of arctic rivers in Finnish Lapland.
Niemi, Jorma
2010-02-01
The water quality monitoring data of eight rivers situated in the Finnish Lapland above the Arctic Circle were investigated. These rivers are icebound annually for about 200 days. They belong to the International River Basin District founded according to the European Union Water Framework Directive and shared with Norway. They are part of the European river monitoring network that includes some 3,400 river sites. The water quality monitoring datasets available varied between the rivers, the longest comprising the period 1975-2003 and the shortest 1989-2003. For each river, annual medians of eight water quality variables were calculated. In addition, medians and fifth and 95th percentiles were calculated for the whole observation periods. The medians indicated good river water quality in comparison to other national or foreign rivers. However, the river water quality oscillated widely. Some rivers were in practice in pristine state, whereas some showed slight human impacts, e.g., occasional high values of hygienic indicator bacteria.
Pellerin, Brian A.; Bergamaschi, Brian A.; Murdoch, Peter S.; Downing, Bryan D.; Saraceno, John Franco; Aiken, George R.; Striegl, Robert G.
2011-01-01
Floods, hurricanes, and longer-term changes in climate and land use can have profound effects on water quality due to shifts in hydrologic flow paths, water residence time, precipitation patterns, connectivity between rivers and uplands, and many other factors. In order to understand and respond to changes in hydrology and water quality, resource managers and policy makers have a need for accurate and early indicators, as well as the ability to assess possible mechanisms and likely outcomes. In-situ optical sensors-those making continuous measurements of constituents by absorbance or fluorescence properties in the environment at timescales of minutes to years-have a long history in oceanography for developing highly resolved concentrations and fluxes, but are not commonly used in freshwater systems. The United States Geological Survey (USGS) has developed the Aquatic Real-Time Monitoring Network, with high-resolution optical data collection for organic carbon, nutrients, and sediment in large coastal rivers, along with continuous measurements of discharge, water temperature, and dissolved inorganic carbon. The collecting of continuous water-quality data in the Nation?s waterways has revealed temporal trends and spatial patterns in constituents that traditional sampling approaches fail to capture, and will serve a critical role in monitoring, assessment and decision-making in a rapidly changing landscape.
Petersson, E-L; Wikberg, C; Westman, J; Ariai, N; Nejati, S; Björkelund, C
2018-05-01
Depression reduces individuals' function and work ability and is associated with both frequent and long-term sickness absence. Investigate if monitoring of depression course using a self-assessment instrument in recurrent general practitioner (GP) consultations leads to improved work ability, decreased job strain, and quality of life among primary care patients. Primary care patients n = 183, who worked. In addition to regular treatment (control group), intervention patients received evaluation and monitoring and used the MADRS-S depression scale during GP visit at baseline and at visits 4, 8, and 12 weeks. Work ability, quality of life and job strain were outcome measures. Depression symptoms decreased in all patients. Significantly steeper increase of WAI at 3 months in the intervention group. Social support was perceived high in a significantly higher frequency in intervention group compared to control group. Monitoring of depression course using a self-assessment instrument in recurrent GP consultations seems to lead to improved self-assessed work ability and increased high social support, but not to reduced job strain or increased quality of life compared to TAU. Future studies concerning rehabilitative efforts that seek to influence work ability probably also should include more active interventions at the workplace.
Quality Control Specialist | Center for Cancer Research
Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID),
NASA Astrophysics Data System (ADS)
Kolosionis, Konstantinos; Papadopoulou, Maria P.
2017-04-01
Monitoring networks provide essential information for water resources management especially in areas with significant groundwater exploitation due to extensive agricultural activities. In this work, a simulation-optimization framework is developed based on heuristic optimization methodologies and geostatistical modeling approaches to obtain an optimal design for a groundwater quality monitoring network. Groundwater quantity and quality data obtained from 43 existing observation locations at 3 different hydrological periods in Mires basin in Crete, Greece will be used in the proposed framework in terms of Regression Kriging to develop the spatial distribution of nitrates concentration in the aquifer of interest. Based on the existing groundwater quality mapping, the proposed optimization tool will determine a cost-effective observation wells network that contributes significant information to water managers and authorities. The elimination of observation wells that add little or no beneficial information to groundwater level and quality mapping of the area can be obtain using estimations uncertainty and statistical error metrics without effecting the assessment of the groundwater quality. Given the high maintenance cost of groundwater monitoring networks, the proposed tool could used by water regulators in the decision-making process to obtain a efficient network design that is essential.
Total Quality Management Simplified.
ERIC Educational Resources Information Center
Arias, Pam
1995-01-01
Maintains that Total Quality Management (TQM) is one method that helps to monitor and improve the quality of child care. Lists four steps for a child-care center to design and implement its own TQM program. Suggests that quality assurance in child-care settings is an ongoing process, and that TQM programs help in providing consistent, high-quality…
Effect of quality metric monitoring and colonoscopy performance.
Razzak, Anthony; Smith, Dineen; Zahid, Maliha; Papachristou, Georgios; Khalid, Asif
2016-10-01
Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.
The Aeroflex: A Bicycle for Mobile Air Quality Measurements
Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout
2013-01-01
Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484
The Aeroflex: a bicycle for mobile air quality measurements.
Elen, Bart; Peters, Jan; Poppel, Martine Van; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout
2012-12-24
Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification.
Findeisen, Peter; Thumfart, Jörg Oliver; Costina, Victor; Hofheinz, Ralf; Neumaier, Michael
2013-09-01
To determine the preanalytical quality of serum and plasma by monitoring the time-dependent ex vivo decay of a synthetic reporter peptide (RP) with liquid chromatography/mass spectrometry (LC/MS). Serum and plasma specimens were spiked with the RP and proteolytic fragments were monitored with LC/MS at different preanalytical time points ranging from 2 to 24 hours after blood withdrawal. The concentration of fragments changed in a time-dependent manner, and respective peptide profiles were used to classify specimens according to their preanalytical time span. Classification accuracy was high, with values always above 0.89 for areas under receiver operating characteristic curves. This "proteomics degradation clock" can be used to estimate the preanalytical quality of serum and plasma and might have impact on quality control procedures of biobanking repositories.
Schildmann, Eva Katharina; Schildmann, Jan; Kiesewetter, Isabel
2015-04-01
Palliative sedation therapy (PST) is increasingly used in patients at the end of life. However, consensus about medications and monitoring is lacking. To assess published PST guidelines with regard to quality and recommendations on drugs and monitoring. We searched CINAHL, the Cochrane Library, Embase, PsycINFO, PubMed, and references of included articles until July 2014. Search terms included "palliative sedation" or "sedation" and "guideline" or "policy" or "framework." Guideline selection was based on English or German publications that included a PST guideline. Two investigators independently assessed the quality of the guidelines according to the Appraisal of Guidelines for Research and Evaluation II instrument (AGREE II) and extracted information on drug selection and monitoring. Nine guidelines were eligible. Eight guidelines received high quality scores for the domain "scope and purpose" (median 69%, range 28-83%), whereas in the other domains the guidelines' quality differed considerably. The majority of guidelines suggest midazolam as drug of first choice. Recommendations on dosage and alternatives vary. The guidelines' recommendations regarding monitoring of PST show wide variation in the number and details of outcome parameters and methods of assessment. The published guidelines on PST vary considerably regarding their quality and content on drugs and monitoring. Given the need for clear guidance regarding PST in patients at the end of life, this comparative analysis may serve as a starting point for further improvement. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Fuzzy intelligent quality monitoring model for X-ray image processing.
Khalatbari, Azadeh; Jenab, Kouroush
2009-01-01
Today's imaging diagnosis needs to adapt modern techniques of quality engineering to maintain and improve its accuracy and reliability in health care system. One of the main factors that influences diagnostic accuracy of plain film X-ray on detecting pathology is the level of film exposure. If the level of film exposure is not adequate, a normal body structure may be interpretated as pathology and vice versa. This not only influences the patient management but also has an impact on health care cost and patient's quality of life. Therefore, providing an accurate and high quality image is the first step toward an excellent patient management in any health care system. In this paper, we study these techniques and also present a fuzzy intelligent quality monitoring model, which can be used to keep variables from degrading the image quality. The variables derived from chemical activity, cleaning procedures, maintenance, and monitoring may not be sensed, measured, or calculated precisely due to uncertain situations. Therefore, the gamma-level fuzzy Bayesian model for quality monitoring of an image processing is proposed. In order to apply the Bayesian concept, the fuzzy quality characteristics are assumed as fuzzy random variables. Using the fuzzy quality characteristics, the newly developed model calculates the degradation risk for image processing. A numerical example is also presented to demonstrate the application of the model.
NASA Astrophysics Data System (ADS)
McGrane, S. J.; Hutchins, M. G.; Kjeldsen, T. R.; Miller, J. D.; Bussi, G.; Loewenthal, M.
2015-12-01
Urban areas are widely recognised as a key source of contaminants entering our freshwater systems, yet in spite of this, our understanding of stormwater quality dynamics remains limited. The development of in-situ, high-resolution monitoring equipment has revolutionised our capability to capture flow and water quality data at a sub-hourly resolution, enabling us to potentially enhance our understanding of hydrochemical variations from contrasting landscapes during storm events. During the winter of 2013/2014, the United Kingdom experienced a succession of intense storm events, where the south of the country experienced 200% of the average rainfall, resulting in widespread flooding across the Thames basin. We applied high-frequency (15 minute resolution) water quality monitoring across ten contrasting subcatchments (including rural, urban and mixed land-use catchments), seeking to classify the disparity in water quality conditions both within- and between events. Rural catchments increasingly behave like "urban" catchments as soils wet up and become increasingly responsive to subsequent events, however water quality response during the winter months remains limited. By contrast, increasingly urban catchments yield greater contaminant loads during events, and pre-event baseline chemistry highlights a resupply source in dense urban catchments. Wastewater treatment plants were shown to dominate baseline chemistry during low-flow events but also yield a considerable impact on stormwater outputs during peak-flow events, as hydraulic push results in the outflow of untreated solid wastes into the river system. Results are discussed in the context of water quality policy; urban growth scenarios and BMP for stormwater runoff in contrasting landscapes.
Ribeiro, Manuel C; Pinho, P; Branquinho, C; Llop, Esteve; Pereira, Maria J
2016-08-15
In most studies correlating health outcomes with air pollution, personal exposure assignments are based on measurements collected at air-quality monitoring stations not coinciding with health data locations. In such cases, interpolators are needed to predict air quality in unsampled locations and to assign personal exposures. Moreover, a measure of the spatial uncertainty of exposures should be incorporated, especially in urban areas where concentrations vary at short distances due to changes in land use and pollution intensity. These studies are limited by the lack of literature comparing exposure uncertainty derived from distinct spatial interpolators. Here, we addressed these issues with two interpolation methods: regression Kriging (RK) and ordinary Kriging (OK). These methods were used to generate air-quality simulations with a geostatistical algorithm. For each method, the geostatistical uncertainty was drawn from generalized linear model (GLM) analysis. We analyzed the association between air quality and birth weight. Personal health data (n=227) and exposure data were collected in Sines (Portugal) during 2007-2010. Because air-quality monitoring stations in the city do not offer high-spatial-resolution measurements (n=1), we used lichen data as an ecological indicator of air quality (n=83). We found no significant difference in the fit of GLMs with any of the geostatistical methods. With RK, however, the models tended to fit better more often and worse less often. Moreover, the geostatistical uncertainty results showed a marginally higher mean and precision with RK. Combined with lichen data and land-use data of high spatial resolution, RK is a more effective geostatistical method for relating health outcomes with air quality in urban areas. This is particularly important in small cities, which generally do not have expensive air-quality monitoring stations with high spatial resolution. Further, alternative ways of linking human activities with their environment are needed to improve human well-being. Copyright © 2016 Elsevier B.V. All rights reserved.
Automated water monitor system field demonstration test report. Volume 2: Technical summary
NASA Technical Reports Server (NTRS)
Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.
1981-01-01
The NASA Automatic Water Monitor System was installed in a water reclamation facility to evaluate the technical and cost feasibility of producing high quality reclaimed water. Data gathered during this field demonstration test are reported.
Monitoring the quality of welding based on welding current and ste analysis
NASA Astrophysics Data System (ADS)
Mazlan, Afidatusshimah; Daniyal, Hamdan; Izzani Mohamed, Amir; Ishak, Mahadzir; Hadi, Amran Abdul
2017-10-01
Qualities of welding play an important part in industry especially in manufacturing field. Post-welding non-destructive test is one of the importance process to ensure the quality of welding but it is time consuming and costly. To reduce the chance of defects, online monitoring had been utilized by continuously sense some of welding parameters and predict welding quality. One of the parameters is welding current, which is rich of information but lack of study focus on extract them at signal analysis level. This paper presents the analysis of welding current using Short Time Energy (STE) signal processing to quantify the pattern of the current. GMAW set with carbon steel specimens are used in this experimental study with high-bandwidth and high sampling rate oscilloscope capturing the welding current. The results indicate welding current as signatures have high correlation with the welding process. Continue with STE analysis, the value below 5000 is declare as good welding, meanwhile the STE value more than 6000 is contained defect.
An Unmanned Aerial Vehicle Cluster Network Cruise System for Monitor
NASA Astrophysics Data System (ADS)
Jiang, Jirong; Tao, Jinpeng; Xin, Guipeng
2018-06-01
The existing maritime cruising system mainly uses manned motorboats to monitor the quality of coastal water and patrol and maintenance of the navigation -aiding facility, which has the problems of high energy consumption, small range of cruise for monitoring, insufficient information control and low visualization. In recent years, the application of UAS in the maritime field has alleviated the phenomenon above to some extent. A cluster-based unmanned network monitoring cruise system designed in this project uses the floating small UAV self-powered launching platform as a carrier, applys the idea of cluster, and combines the strong controllability of the multi-rotor UAV and the capability to carry customized modules, constituting a unmanned, visualized and normalized monitoring cruise network to realize the functions of maritime cruise, maintenance of navigational-aiding and monitoring the quality of coastal water.
Reservoir vital signs monitoring, 1990: Physical and chemical characteristics of water and sediments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meinert, D.L.
1991-05-01
As part of Tennessee Valley Authority's (TVA's) Reservoir Vital Signs Monitoring program, physical/chemical measurements of water and sediment were made in 1990 on twelve TVA reservoirs (the nine main steam Tennessee river reservoirs - Kentucky through Fort Loudoun and three major tributary reservoirs - Cherokee, Douglas, and Norris). The objective of this monitoring program is to assess the health or integrity of these aquatic ecosystems. The physical/chemical water quality data collected in 1990 showed the water quality of these reservoirs to be very good. However, hypolimnetic anoxia during the summer months in Watts bars, Douglas, and Cherokee reservoir continues tomore » be a concern. High concentrations of nutrients were measured in the transition zones of Cherokee and Douglas reservoirs, resulting in highly productive and eutrophic conditions in the transition zones of these reservoirs. Fecal coliform organisms were frequently detected in the forebay area of Guntersville reservoir, and higher than expected ammonia nitrogen concentrations were found at the transition zone of Wheeler reservoir. Elevated concentrations of mercury were found in Pickwick and Watts bar reservoir sediment, and high lead concentrations were found in a sediment sample collected from Guntersville reservoir. A TVA Reservoir Water Quality Index (RWQI) was developed and used to summarize water quality conditions on a scale from 0 (worst) to 100 (best).« less
Oxley, Cristal; Moghraby, Omer S; Samuel, Rani; Joyce, Dan W
2018-01-01
Attention deficit hyperactivity disorder (ADHD) is a common neurodevelopmental disorder characterised by a persistent, pervasive pattern of inattention, impulsivity and hyperactivity. Stimulant medication such as methylphenidate has an established evidence base in the treatment of children and adolescents with ADHD. However, it is also associated with a risk of side effects which may include decreased appetite, increased blood pressure and possible reduced growth. Monitoring physical health in children and adolescents prescribed medication for ADHD is a key clinical responsibility and includes a number of parameters as outlined in the National Institute for Health and Care Excellence Guidelines. Ascertaining the centiles of physical observations is essential to put these into developmental context and accurately inform treatment decisions. This quality improvement project aimed to improve physical health monitoring in children and adolescents prescribed stimulant medication for ADHD within a large specialist urban inner-city Child and Adolescent Mental Health Service (CAMHS) in South London and Maudsley NHS Foundation Trust. Baseline data were obtained to establish the quality of physical monitoring including blood pressure, height, weight and centiles. Targeted interventions included the development of a novel web-based application designed to calculate and record centiles. We report an improvement in total proportion compliance with physical health monitoring from 24% to 75%. The frequency of recording baseline blood pressure centiles increased from 0% to 62%; recording baseline height centiles increased from 37% to 81% and recording baseline weight centiles increased from 37% to 81%. Improvement in the delivery of high-quality care was achieved and sustained through close collaboration with clinicians involved in the treatment pathway in order to elicit and respond effectively to feedback for improvement and codevelop interventions which were highly effective within the clinical system. We believe this model to be replicable in other CAMHS services and ADHD clinics to improve the delivery of high-quality clinical care.
A monitoring approach combining wet chemistry and high frequency (HF) water quality sensors has been employed to improve our understanding of the ecology of an inland reservoir with a history of cyanoHAB events. Lake Harsha is a multi-use reservoir managed by the USACE in southwe...
Lee, Yi-Hsuan; von Davier, Alina A
2013-07-01
Maintaining a stable score scale over time is critical for all standardized educational assessments. Traditional quality control tools and approaches for assessing scale drift either require special equating designs, or may be too time-consuming to be considered on a regular basis with an operational test that has a short time window between an administration and its score reporting. Thus, the traditional methods are not sufficient to catch unusual testing outcomes in a timely manner. This paper presents a new approach for score monitoring and assessment of scale drift. It involves quality control charts, model-based approaches, and time series techniques to accommodate the following needs of monitoring scale scores: continuous monitoring, adjustment of customary variations, identification of abrupt shifts, and assessment of autocorrelation. Performance of the methodologies is evaluated using manipulated data based on real responses from 71 administrations of a large-scale high-stakes language assessment.
SUPERFUND INNOVATIVE TECHNOLOGIES EVALUATION ...
This task seeks to identify high priority needs of the Regions and Program Offices for innovative field sampling, characterization, monitoring, and measurement technologies. When an appropriate solution to a specific problem is identified, a field demonstration is conducted to document the performance and cost of the proposed technologies. The use of field analysis almost always provides a savings in time and cost over the usual sample and ship to a conventional laboratory for analysis approach to site characterization and monitoring. With improvements in technology and appropriate quality assurance/quality control, field analysis has been shown to provide high quality data, useful for most environmental monitoring or characterization projects. An emphasis of the program is to seek out innovative solutions to existing problems and to provide the cost and performance data a user would require to make an informed decision regarding the adequacy of a technology to address a specific environmental problem. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Scientific Framework for Stormwater Monitoring by the Washington State Department of Transportation
Sheibley, R.W.; Kelly, V.J.; Wagner, R.J.
2009-01-01
The Washington State Department of Transportation municipal stormwater monitoring program, in operation for about 8 years, never has received an external, objective assessment. In addition, the Washington State Department of Transportation would like to identify the standard operating procedures and quality assurance protocols that must be adopted so that their monitoring program will meet the requirements of the new National Pollutant Discharge Elimination System municipal stormwater permit. As a result, in March 2009, the Washington State Department of Transportation asked the U.S. Geological Survey to assess their pre-2009 municipal stormwater monitoring program. This report presents guidelines developed for the Washington State Department of Transportation to meet new permit requirements and regional/national stormwater monitoring standards to ensure that adequate processes and procedures are identified to collect high-quality, scientifically defensible municipal stormwater monitoring data. These include: (1) development of coherent vision and cooperation among all elements of the program; (2) a comprehensive approach for site selection; (3) an effective quality assurance program for field, laboratory, and data management; and (4) an adequate database and data management system.
George, Stephen L; Buyse, Marc
2015-01-01
Highly publicized cases of fabrication or falsification of data in clinical trials have occurred in recent years and it is likely that there are additional undetected or unreported cases. We review the available evidence on the incidence of data fraud in clinical trials, describe several prominent cases, present information on motivation and contributing factors and discuss cost-effective ways of early detection of data fraud as part of routine central statistical monitoring of data quality. Adoption of these clinical trial monitoring procedures can identify potential data fraud not detected by conventional on-site monitoring and can improve overall data quality. PMID:25729561
Toward determining melt pool quality metrics via coaxial monitoring in laser powder bed fusion.
Fisher, Brian A; Lane, Brandon; Yeung, Ho; Beuth, Jack
2018-01-01
The current industry trend in metal additive manufacturing is towards greater real time process monitoring capabilities during builds to ensure high quality parts. While the hardware implementations that allow for real time monitoring of the melt pool have advanced significantly, the knowledge required to correlate the generated data to useful metrics of interest are still lacking. This research presents promising results that aim to bridge this knowledge gap by determining a novel means to correlate easily obtainable sensor data (thermal emission) to key melt pool size metrics (e.g., melt pool cross sectional area).
Pope, Larry M.; Rosner, Stacy M.; Hoffman, Darren C.; Ziegler, Andrew C.
2004-01-01
The investigation described in this report summarized data from State ambient stream-water-quality monitoring sites for 10 water-quality constituents or measurements (suspended solids, fecal coliform bacteria, ammonia as nitrogen, nitrite plus nitrate as nitrogen, total phosphorus, total arsenic, dissolved solids, chloride, sulfate, and pH). These 10 water-quality constituents or measurements commonly are listed nationally as major contributors to degradation of surface water. Water-quality data were limited to that electronically accessible from the U.S. Environmental Protection Agency Storage and Retrieval System (STORET), the U.S. Geological Survey National Water Information System (NWIS), or individual State databases. Forty-two States had ambient stream-water-quality data electronically accessible for some or all of the constituents or measurements summarized during this investigation. Ambient in this report refers to data collected for the purpose of evaluating stream ecosystems in relation to human health, environmental and ecological conditions, and designated uses. Generally, data were from monitoring sites assessed for State 305(b) reports. Comparisons of monitoring data among States are problematic for several reasons, including differences in the basic spatial design of monitoring networks; water-quality constituents for which samples are analyzed; water-quality criteria to which constituent concentrations are compared; quantity and comprehensiveness of water-quality data; sample collection, processing, and handling; analytical methods; temporal variability in sample collection; and quality-assurance practices. Large differences among the States in number of monitoring sites precluded a general assumption that statewide water-quality conditions were represented by data from these sites. Furthermore, data from individual monitoring sites may not represent water-quality conditions at the sites because sampling conditions and protocols are unknown. Because of these factors, a high level of uncertainty exists in a national assessment of water quality. The purpose of this report is to present a summary of electronically available State ambient stream-water-quality data for 10 selected constituents and measurements from monitoring sites with nine or more analyses for 199098 and to discuss limitations for use of the data for national assessment. These analyses were statistiscally summarized by monitoring site and State, and the results presented in tabular format. Most of the selected constituents or measurements have U.S. Environmental Protection Agency criteria or guidelines for aquatic-life or drinking-water purposes. A significant finding of this investigation is that for a large percentage of monitoring sites in the Nation, there are insufficient data to meet U.S. Environmental Protection Agency recommendations for determining if water-quality conditions are degraded and for making informed decisions regarding total maximum daily loads.
Thermoelectric converters for monitoring the temperature of salt baths
NASA Astrophysics Data System (ADS)
Spektor, Yu. A.
1985-02-01
It is recommended to use RTEC in lieu of a radiational pyrometer and an STEC to monitor and maintain the temperature automatically in high-temperature salt melts; this contributes to a marked improvement in the quality of heat-treated components.
Toro A, Richard; Campos, Claudia; Molina, Carolina; Morales S, Raul G E; Leiva-Guzmán, Manuel A
2015-09-01
A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quality control of the measurements are reported. In contrast, events that cause saturation of the monitoring detectors located in northern and southern Chile have been observed using beta attenuation monitoring. In these cases, it can only be concluded that the PM content is equal to or greater than the saturation concentration registered by the monitors and that the air quality indexes obtained from these measurements are underestimated. This occurrence has been observed in 12 (20) public and private stations where PM2.5 (PM10) is measured. The shortcomings of the NAQIS data have important repercussions for the conclusions obtained from the data and for how the data are used. However, these issues represent opportunities for improving the system to widen its use, incorporate comparison protocols between equipment, install new stations and standardize the control system and quality assurance. Copyright © 2015 Elsevier Ltd. All rights reserved.
Landers, Mark N.
2013-01-01
The U.S. Geological Survey, in cooperation with the Gwinnett County Department of Water Resources, established a water-quality monitoring program during late 1996 to collect comprehensive, consistent, high-quality data for use by watershed managers. As of 2009, continuous streamflow and water-quality data as well as discrete water-quality samples were being collected for 14 watershed monitoring stations in Gwinnett County. This report provides statistical summaries of total suspended solids (TSS) concentrations for 730 stormflow and 710 base-flow water-quality samples collected between 1996 and 2009 for 14 watershed monitoring stations in Gwinnett County. Annual yields of TSS were estimated for each of the 14 watersheds using methods described in previous studies. TSS yield was estimated using linear, ordinary least-squares regression of TSS and explanatory variables of discharge, turbidity, season, date, and flow condition. The error of prediction for estimated yields ranged from 1 to 42 percent for the stations in this report; however, the actual overall uncertainty of the estimated yields cannot be less than that of the observed yields (± 15 to 20 percent). These watershed yields provide a basis for evaluation of how watershed characteristics, climate, and watershed management practices affect suspended sediment yield.
Monitoring the delivery of cancer care: Commission on Cancer and National Cancer Data Base.
Williams, Richelle T; Stewart, Andrew K; Winchester, David P
2012-07-01
The primary objective of the Commission on Cancer (CoC) is to ensure the delivery of comprehensive, high-quality care that improves survival while maintaining quality of life for patients with cancer. This article examines the initiatives of the CoC toward achieving this goal, utilizing data from the National Cancer Data Base (NCDB) to monitor treatment patterns and outcomes, to develop quality measures, and to benchmark hospital performance. The article also highlights how these initiatives align with the Institute of Medicine's recommendations for improving the quality of cancer care and briefly explores future projects of the CoC and NCDB. Copyright © 2012 Elsevier Inc. All rights reserved.
McDonald, Kathryn M; Su, George; Lisker, Sarah; Patterson, Emily S; Sarkar, Urmimala
2017-06-24
Missed evidence-based monitoring in high-risk conditions (e.g., cancer) leads to delayed diagnosis. Current technological solutions fail to close this safety gap. In response, we aim to demonstrate a novel method to identify common vulnerabilities across clinics and generate attributes for context-flexible population-level monitoring solutions for widespread implementation to improve quality. Based on interviews with staff in otolaryngology, pulmonary, urology, breast, and gastroenterology clinics at a large urban publicly funded health system, we applied journey mapping to co-develop a visual representation of how patients are monitored for high-risk conditions. Using a National Academies framework and context-sensitivity theory, we identified common systems vulnerabilities and developed preliminary concepts for improving the robustness for monitoring patients with high-risk conditions ("design seeds" for potential solutions). Finally, we conducted a face validity and prioritization assessment of the design seeds with the original interviewees. We identified five high-risk situations for potentially consequential diagnostic delays arising from suboptimal patient monitoring. All situations related to detection of cancer (head and neck, lung, prostate, breast, and colorectal). With clinic participants we created 5 journey maps, each representing specialty clinic workflow directed at evidence-based monitoring. System vulnerabilities common to the different clinics included challenges with: data systems, communications handoffs, population-level tracking, and patient activities. Clinic staff ranked 13 design seeds (e.g., keep patient list up to date, use triggered notifications) addressing these vulnerabilities. Each design seed has unique evaluation criteria for the usefulness of potential solutions developed from the seed. We identified and ranked 13 design seeds that characterize situations that clinicians described 'wake them up at night', and thus could reduce their anxiety, save time, and improve monitoring of high-risk patients. We anticipate that the design seed approach promotes robust and context-sensitive solutions to safety and quality problems because it provides a human-centered link between the experienced problem and various solutions that can be tested for viability. The study also demonstrates a novel integration of industrial and human factors methods (journey mapping, process tracing and design seeds) linked to implementation theory for use in designing interventions that anticipate and reduce implementation challenges.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT NATIONAL... systematic basis for developing a high quality estuarine resource and ecosystem information base for National... monitoring programs as part of operations and management under § 921.32. Monitoring funds are used to support...
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT NATIONAL... systematic basis for developing a high quality estuarine resource and ecosystem information base for National... monitoring programs as part of operations and management under § 921.32. Monitoring funds are used to support...
Playing Chemical Plant Environmental Protection Games with Historical Monitoring Data.
Zhu, Zhengqiu; Chen, Bin; Reniers, Genserik; Zhang, Laobing; Qiu, Sihang; Qiu, Xiaogang
2017-09-29
The chemical industry is very important for the world economy and this industrial sector represents a substantial income source for developing countries. However, existing regulations on controlling atmospheric pollutants, and the enforcement of these regulations, often are insufficient in such countries. As a result, the deterioration of surrounding ecosystems and a quality decrease of the atmospheric environment can be observed. Previous works in this domain fail to generate executable and pragmatic solutions for inspection agencies due to practical challenges. In addressing these challenges, we introduce a so-called Chemical Plant Environment Protection Game (CPEP) to generate reasonable schedules of high-accuracy air quality monitoring stations (i.e., daily management plans) for inspection agencies. First, so-called Stackelberg Security Games (SSGs) in conjunction with source estimation methods are applied into this research. Second, high-accuracy air quality monitoring stations as well as gas sensor modules are modeled in the CPEP game. Third, simplified data analysis on the regularly discharging of chemical plants is utilized to construct the CPEP game. Finally, an illustrative case study is used to investigate the effectiveness of the CPEP game, and a realistic case study is conducted to illustrate how the models and algorithms being proposed in this paper, work in daily practice. Results show that playing a CPEP game can reduce operational costs of high-accuracy air quality monitoring stations. Moreover, evidence suggests that playing the game leads to more compliance from the chemical plants towards the inspection agencies. Therefore, the CPEP game is able to assist the environmental protection authorities in daily management work and reduce the potential risks of gaseous pollutants dispersion incidents.
Automated locomotor activity monitoring as a quality control assay for mass-reared tephritid flies.
Dominiak, Bernard C; Fanson, Benjamin G; Collins, Samuel R; Taylor, Phillip W
2014-02-01
The Sterile Insect Technique (SIT) requires vast numbers of consistently high quality insects to be produced over long periods. Quality control (QC) procedures are critical to effective SIT, both providing quality assurance and warning of operational deficiencies. We here present a potential new QC assay for mass rearing of Queensland fruit flies (Bactrocera tryoni Froggatt) for SIT; locomotor activity monitoring. We investigated whether automated locomotor activity monitors (LAMs) that simply detect how often a fly passes an infrared sensor in a glass tube might provide similar insights but with much greater economy. Activity levels were generally lower for females than for males, and declined over five days in the monitor for both sexes. Female activity levels were not affected by irradiation, but males irradiated at 60 or 70 Gy had reduced activity levels compared with unirradiated controls. We also found some evidence that mild heat shock of pupae results in adults with reduced activity. LAM offers a convenient, effective and economical assay to probe such changes. © 2013 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Haiyang, Yu; Yanmei, Liu; Guijun, Yang; Xiaodong, Yang; Dong, Ren; Chenwei, Nie
2014-03-01
To achieve dynamic winter wheat quality monitoring and forecasting in larger scale regions, the objective of this study was to design and develop a winter wheat quality monitoring and forecasting system by using a remote sensing index and environmental factors. The winter wheat quality trend was forecasted before the harvest and quality was monitored after the harvest, respectively. The traditional quality-vegetation index from remote sensing monitoring and forecasting models were improved. Combining with latitude information, the vegetation index was used to estimate agronomy parameters which were related with winter wheat quality in the early stages for forecasting the quality trend. A combination of rainfall in May, temperature in May, illumination at later May, the soil available nitrogen content and other environmental factors established the quality monitoring model. Compared with a simple quality-vegetation index, the remote sensing monitoring and forecasting model used in this system get greatly improved accuracy. Winter wheat quality was monitored and forecasted based on the above models, and this system was completed based on WebGIS technology. Finally, in 2010 the operation process of winter wheat quality monitoring system was presented in Beijing, the monitoring and forecasting results was outputted as thematic maps.
Fetal electrocardiogram (ECG) for fetal monitoring during labour.
Neilson, James P
2015-12-21
Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average fewer fetal scalp samples taken during labour (average RR 0.61, 95% CI 0.41 to 0.91; four trials, 9671 babies; high quality evidence) although the findings were heterogeneous and there were no data from the largest trial (from the USA). There were marginally fewer operative vaginal births (RR 0.92, 95% CI 0.86 to 0.99; six trials, 26,446 women); but no obvious difference in the number of babies with low Apgar scores at five minutes or babies requiring neonatal intubation, or babies requiring admission to the special care unit (RR 0.96, 95% CI 0.89 to 1.04, six trials, 26,410 babies; high quality evidence). There was little evidence that monitoring by PR interval analysis conveyed any benefit of any sort. The modest benefits of fewer fetal scalp samplings during labour (in settings in which this procedure is performed) and fewer instrumental vaginal births have to be considered against the disadvantages of needing to use an internal scalp electrode, after membrane rupture, for ECG waveform recordings. We found little strong evidence that ST waveform analysis had an effect on the primary outcome measures in this systematic review.There was a lack of evidence showing that PR interval analysis improved any outcomes; and a larger future trial may possibly demonstrate beneficial effects.There is little information about the value of fetal ECG waveform monitoring in preterm fetuses in labour. Information about long-term development of the babies included in the trials would be valuable.
NASA Astrophysics Data System (ADS)
Stadler, Philipp; Farnleitner, Andreas H.; Sommer, Regina; Kumpan, Monika; Zessner, Matthias
2014-05-01
For the near real time and on-site detection of microbiological fecal pollution of water, the measurement of beta-D- Glucuronidase (GLUC) enzymatic activity has been suggested as a surrogate parameter and has been already successfully operated for water quality monitoring of ground water resources (Ryzinska-Paier et al. 2014). Due to possible short measure intervals of three hours, this method has high potential as a water quality monitoring tool. While cultivation based standard determination takes more than one working day (Cabral 2010) the potential advantage of detecting the GLUC activity is the high temporal measuring resolution. Yet, there is still a big gap of knowledge on the fecal indication capacity of GLUC (specificity, sensitivity, persistence, etc.) in relation to potential pollution sources and catchment conditions (Cabral 2010, Ryzinska-Paier et al. 2014). Furthermore surface waters are a big challenge for automated detection devices in a technical point of view due to the high sediment load during event conditions. This presentation shows results gained form two years of monitoring in an experimental catchment (HOAL) dominated by agricultural land use. Two enzymatic measurement devices are operated parallel at the catchment outlet to test the reproducibility and precision of the method. Data from continuous GLUC monitoring under both base flow and event conditions is compared with reference samples analyzed by standardized laboratory methods for fecal pollution detection (e.g. ISO 16649-1, Colilert18). It is shown that rapid enzymatic on-site GLUC determination can successfully be operated from a technical point of view for surface water quality monitoring under the observed catchment conditions. The comparison of enzyme activity with microbiological standard analytics reveals distinct differences in the dynamic of the signals during event conditions. Cabral J. P. S. (2010) "Water Microbiology. Bacterial Pathogens and Water" International Journal of Environmental Research and Public Health 7 (10): 3657-3703. Ryzinska-Paier, G., T. Lendenfeld, K. Correa, P. Stadler, A.P. Blaschke, R. L. Mach, H. Stadler, AKT Kirschner und A.H. Farnleitner (2014) A sensitive and robust method for automated on-line monitoring of enzymatic activities in water and water resources. Water Sci. Technol. in press
Preparation and analysis of zero gases for the measurement of trace VOCs in air monitoring
NASA Astrophysics Data System (ADS)
Englert, Jennifer; Claude, Anja; Demichelis, Alessia; Persijn, Stefan; Baldan, Annarita; Li, Jianrong; Plass-Duelmer, Christian; Michl, Katja; Tensing, Erasmus; Wortman, Rina; Ghorafi, Yousra; Lecuna, Maricarmen; Sassi, Guido; Sassi, Maria Paola; Kubistin, Dagmar
2018-06-01
Air quality observations are performed globally to monitor the status of the atmosphere and its level of pollution and to assess mitigation strategies. Regulations of air quality monitoring programmes in various countries demand high-precision measurements for harmful substances often at low trace concentrations. These requirements can only be achieved by using high-quality calibration gases including high-purity zero gas. For volatile organic compound (VOC) observations, zero gas is defined as being hydrocarbon-free and can be, for example, purified air, nitrogen or helium. It is essential for the characterisation of the measurement devices and procedures, for instrument operation as well as for calibrations. Two commercial and one self-built gas purifiers were tested for their VOC removal efficiency following a standardised procedure. The tested gas purifiers included one adsorption cartridge with an inorganic media and two types of metal catalysts. A large range of VOCs were investigated, including the most abundant species typically measured at air monitoring stations. Both catalysts were able to remove a large range of VOCs whilst the tested adsorption cartridge was not suitable to remove light compounds up to C4. Memory effects occurred for the adsorption cartridge when exposed to higher concentration. This study emphasises the importance of explicitly examining a gas purifier for its intended application before applying it in the field.
USDA-ARS?s Scientific Manuscript database
Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...
NASA Astrophysics Data System (ADS)
Murray, G.; Weihrauch, D.; Kimball, K.; McDonough, C.
2010-12-01
The AMC’s citizen scientist monitoring program, Mountain Watch, engages hikers in observational monitoring while recreating in the northern Appalachian Mountains. The program uses two monitoring activities:1) tracking the phenology of 11 mountain flowers species, and 2) the visitors real world perception of on-mountain visibility and its ‘quality’ with proximate monitored air quality parameters. The Mountain Watch program objectives are a) to engage and educate the public through hands-on monitoring, b) to motivate the participant to take further action towards environmental stewardship, and c) to provide supplemental data to AMC’s ongoing science-based research to further our understanding of the impact of human activity on mountain ecosystems. The Mountain Watch plant monitoring includes recording the time and location of alpine and forest plants flowering and other phenological phases using AMC field guides and datasheets. In the White Mountains of New Hampshire concurrent meteorological data, including soil temperature, is paired with the phenology observations as part of AMC’s research to develop spatial and temporal phenology models with air and soil temperature for northeastern mountains. Mountain Watch’s visibility monitoring program has hikers record visual range and rate the view at select vistas in comparison to a clear day view photo guide when visiting AMC’s backcountry huts. The results are compared to proximate air quality measurements, which assists in determining how White Mountain National Forest air quality related values and natural resources management objectives are being met. Since 2006 the Mountain Watch program has received over 3,500 citizen datasheets for plant reproductive phenology and visibility monitoring. We estimate that we have reached more than 15,000 hikers through our facility based education programming focused on air quality and phenology and field monitoring hikes. While we consider this good success in engaging hikers to date, the ratio of resource expenditures in recruiting volunteers and QA/QCing their data for actual research application has been high. Mountain Watch staff are now refining the program to achieve education and research goals a manner that is sustainable into the future with limited fiscal and staff resources. The quality of our citizen phenology observations, in comparison to staff monitoring, has lead to refinements including directing general audience hikers to well-defined trailside observation stations, growing our more skilled amateur botanist volunteer base, and use of remote cameras for quality controls and better temporal coverage. Visibility monitoring at four mountain vistas has recently been analyzed in the context of policy applications. Refinements will be presented that will further inform natural resource management of air quality in relation to Clean Air Act Air Quality Related Values and a potential visibility focused particulate matter secondary National Ambient Air Quality Standard. Overall lessons learned, regarding audience considerations, resource needs, and long-term sustainability, from our 5-year field based geoscience programs will be discussed.
Technology transfer potential of an automated water monitoring system. [market research
NASA Technical Reports Server (NTRS)
Jamieson, W. M.; Hillman, M. E. D.; Eischen, M. A.; Stilwell, J. M.
1976-01-01
The nature and characteristics of the potential economic need (markets) for a highly integrated water quality monitoring system were investigated. The technological, institutional and marketing factors that would influence the transfer and adoption of an automated system were studied for application to public and private water supply, public and private wastewater treatment and environmental monitoring of rivers and lakes.
Persenius, Mona; Hall-Lord, Marie-Louise; Wilde-Larsson, Bodil; Carlsson, Eva
2015-09-01
To describe nursing leaders' perceptions of nutrition quality in Swedish stroke wards. A high risk of undernutrition places great demand on nutritional care in stroke wards. Evidence-based guidelines exist, but healthcare professionals have reported low interest in nutritional care. The Donabedian framework of structure, process and outcome is recommended to monitor and improve nutrition quality. Using a descriptive cross-sectional design, a web-based questionnaire regarding nutritional care quality was delivered to eligible participants. Most clinical nursing leaders reported structure indicators, e.g. access to dieticians. Among process indicators, regular assessment of patients' swallowing was most frequently reported in comprehensive stroke wards compared with other stroke wards. Use of outcomes to monitor nutrition quality was not routine. Wards using standard care plans showed significantly better results. Using the structure, process and outcome framework to examine nutrition quality, quality-improvement needs became visible. To provide high-quality nutrition, all three structure, process and outcome components must be addressed. The use of care pathways, standard care plans, the Senior Alert registry, as well as systematic use of outcome measures could improve nutrition quality. To assist clinical nursing leaders in managing all aspects of quality, structure, process and outcome can be a valuable framework. © 2013 John Wiley & Sons Ltd.
Assessing air quality impacts of managed lanes.
DOT National Transportation Integrated Search
2010-12-01
Impacts on transit bus performance and air quality were investigated for a case study high-occupancy / toll (HOT) lane project on a corridor of I-95 near Miami. Trends in air pollutant concentration monitoring data in the study area first were analyz...
Assessing air quality impacts of managed lanes
DOT National Transportation Integrated Search
2010-12-01
Impacts on transit bus performance and air quality were investigated for a case study high-occupancy / : toll (HOT) lane project on a corridor of I-95 near Miami. Trends in air pollutant concentration : monitoring data in the study area first were an...
[A new method for safety monitoring of natural dietary supplements--quality profile].
Wang, Juan; Wang, Li-Ping; Yang, Da-Jin; Chen, Bo
2008-07-01
A new method for safety monitoring of natural dietary supplements--quality profile was proposed. It would convert passive monitoring of synthetic drug to active, and guarantee the security of natural dietary supplements. Preliminary research on quality profile was completed by high performance liquid chromatography (HPLC) and mass spectrometry (MS). HPLC was employed to analyze chemical constituent profiles of natural dietary supplements. The separation was completed on C18 column with acetonitrile and water (0.05% H3PO4) as mobile phase, the detection wavelength was 223 nm. Based on HPLC, stability of quality profile had been studied, and abnormal compounds in quality profile had been analyzed after addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide. And by MS, detector worked with ESI +, capillary voltage: 3.5 kV, cone voltage: 30 V, extractor voltage: 4 V, RF lens voltage: 0.5 V, source temperature: 105 degrees C, desolvation temperature: 300 degrees C, desolvation gas flow rate: 260 L/h, cone gas flow rate: 50 L/h, full scan mass spectra: m/z 100-600. Abnormal compound in quality profile had been analyzed after addition of N-mono-desmethyl sibutramine. Quality profile based on HPLC had good stability (Similarity > 0.877). Addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide in natural dietary supplements could be reflected by HPLC, and addition of N-mono-desmethyl sibutramine in natural dietary supplements could be reflected by MS. Quality profile might monitor adulteration of natural dietary supplements, and prevent addition of synthetic drug after "approval".
Reservoir vital signs monitoring, 1990: Physical and chemical characteristics of water and sediments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meinert, D.L.
1991-05-01
As part of Tennessee Valley Authority`s (TVA`s) Reservoir Vital Signs Monitoring program, physical/chemical measurements of water and sediment were made in 1990 on twelve TVA reservoirs (the nine main steam Tennessee river reservoirs - Kentucky through Fort Loudoun and three major tributary reservoirs - Cherokee, Douglas, and Norris). The objective of this monitoring program is to assess the health or integrity of these aquatic ecosystems. The physical/chemical water quality data collected in 1990 showed the water quality of these reservoirs to be very good. However, hypolimnetic anoxia during the summer months in Watts bars, Douglas, and Cherokee reservoir continues tomore » be a concern. High concentrations of nutrients were measured in the transition zones of Cherokee and Douglas reservoirs, resulting in highly productive and eutrophic conditions in the transition zones of these reservoirs. Fecal coliform organisms were frequently detected in the forebay area of Guntersville reservoir, and higher than expected ammonia nitrogen concentrations were found at the transition zone of Wheeler reservoir. Elevated concentrations of mercury were found in Pickwick and Watts bar reservoir sediment, and high lead concentrations were found in a sediment sample collected from Guntersville reservoir. A TVA Reservoir Water Quality Index (RWQI) was developed and used to summarize water quality conditions on a scale from 0 (worst) to 100 (best).« less
Lavine; Snyder
1996-11-01
In two experiments, we examined the hypothesis that subjective perceptions of message quality mediate the functional matching effect in persuasion. In Experiment 1, participants whose attitudes and behaviors serve primarily a value-expressive function (i.e., low self-monitors) or a social-adjustive function (i.e., high self-monitors) were exposed to persuasive messages that contained value-expressive, social-adjustive, or both types of arguments in favor of voting. Functionally-relevant messages (i.e., the social-adjustive message for high self-monitors and the value-expressive message for low self-monitors) produced enhanced perceptions of message quality and persuasiveness, more positive attitudes, and more message-related behavior than functionally nonrelevant messages. Functionally mixed messages were generally more effective than messages containing only functionally nonrelevant arguments, but less effective than messages containing only functionally relevant arguments. Path analyses indicated that the influence of functional relevance on attitudes and behavior was significantly mediated by subjective perceptions of the quality of the message. In Experiment 2, we exposed participants to a functionally relevant or nonrelevant voting appeal five days before a presidential election. Results replicated those of Experiment 1; functionally relevant messages produced more favorable attitudes, and this effect was mediated by enhanced perceptions of message quality. Finally, postmessage attitudes exerted a significant influence on whether participants voted in the election, and this effect was mediated by voting intentions. Discussion focuses on the subjective nature of message evaluation and on the cognitive processes underlying the functional matching effect in persuasion.
Structural Colour in Colourimetric Sensors and Indicators
2013-07-11
for disease detection at a hospital).6–8 For these problems, many highly sophisticated chemical analysis technologies have emerged, such as high...fulls important functions in society such as disease diagnosis, health and safety monitoring, threat and hazard detection, and industrial quality...demand for devices that can detect and identify small mole- cules. Health-monitoring and disease diagnosis frequently require tracking the levels of
Water-quality response to a high-elevation wildfire in the Colorado Front Range
Mast, M. Alisa; Murphy, Sheila F.; Clow, David W.; Penn, Colin A.; Sexstone, Graham A.
2016-01-01
Water quality of the Big Thompson River in the Front Range of Colorado was studied for 2 years following a high-elevation wildfire that started in October 2012 and burned 15% of the watershed. A combination of fixed-interval sampling and continuous water-quality monitors was used to examine the timing and magnitude of water-quality changes caused by the wildfire. Prefire water quality was well characterized because the site has been monitored at least monthly since the early 2000s. Major ions and nitrate showed the largest changes in concentrations; major ion increases were greatest in the first postfire snowmelt period, but nitrate increases were greatest in the second snowmelt period. The delay in nitrate release until the second snowmelt season likely reflected a combination of factors including fire timing, hydrologic regime, and rates of nitrogen transformations. Despite the small size of the fire, annual yields of dissolved constituents from the watershed increased 20–52% in the first 2 years following the fire. Turbidity data from the continuous sensor indicated high-intensity summer rain storms had a much greater effect on sediment transport compared to snowmelt. High-frequency sensor data also revealed that weekly sampling missed the concentration peak during snowmelt and short-duration spikes during rain events, underscoring the challenge of characterizing postfire water-quality response with fixed-interval sampling.
Parra, Lorena; García, Laura
2018-01-01
The monitoring of farming processes can optimize the use of resources and improve its sustainability and profitability. In fish farms, the water quality, tank environment, and fish behavior must be monitored. Wireless sensor networks (WSNs) are a promising option to perform this monitoring. Nevertheless, its high cost is slowing the expansion of its use. In this paper, we propose a set of sensors for monitoring the water quality and fish behavior in aquaculture tanks during the feeding process. The WSN is based on physical sensors, composed of simple electronic components. The system proposed can monitor water quality parameters, tank status, the feed falling and fish swimming depth and velocity. In addition, the system includes a smart algorithm to reduce the energy waste when sending the information from the node to the database. The system is composed of three nodes in each tank that send the information though the local area network to a database on the Internet and a smart algorithm that detects abnormal values and sends alarms when they happen. All the sensors are designed, calibrated, and deployed to ensure its suitability. The greatest efforts have been accomplished with the fish presence sensor. The total cost of the sensors and nodes for the proposed system is less than 90 €. PMID:29494560
Parra, Lorena; Sendra, Sandra; García, Laura; Lloret, Jaime
2018-03-01
The monitoring of farming processes can optimize the use of resources and improve its sustainability and profitability. In fish farms, the water quality, tank environment, and fish behavior must be monitored. Wireless sensor networks (WSNs) are a promising option to perform this monitoring. Nevertheless, its high cost is slowing the expansion of its use. In this paper, we propose a set of sensors for monitoring the water quality and fish behavior in aquaculture tanks during the feeding process. The WSN is based on physical sensors, composed of simple electronic components. The system proposed can monitor water quality parameters, tank status, the feed falling and fish swimming depth and velocity. In addition, the system includes a smart algorithm to reduce the energy waste when sending the information from the node to the database. The system is composed of three nodes in each tank that send the information though the local area network to a database on the Internet and a smart algorithm that detects abnormal values and sends alarms when they happen. All the sensors are designed, calibrated, and deployed to ensure its suitability. The greatest efforts have been accomplished with the fish presence sensor. The total cost of the sensors and nodes for the proposed system is less than 90 €.
40 CFR 60.2170 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2013 CFR
2013-07-01
... monitoring system quality assurance or quality control activities (including, as applicable, calibration... required monitoring system quality assurance or quality control activities including, as applicable... required monitoring system quality assurance or control activities in calculations used to report emissions...
DOT National Transportation Integrated Search
2005-02-01
Annual average PM10 concentrations at the Greenwood monitoring station in western Phoenix have : exceeded EPAs annual average air quality standard and are higher on average than values observed at the : West Phoenix monitor, which is located just ...
NASA Astrophysics Data System (ADS)
Taylan, Osman
2017-02-01
High ozone concentration is an important cause of air pollution mainly due to its role in the greenhouse gas emission. Ozone is produced by photochemical processes which contain nitrogen oxides and volatile organic compounds in the lower atmospheric level. Therefore, monitoring and controlling the quality of air in the urban environment is very important due to the public health care. However, air quality prediction is a highly complex and non-linear process; usually several attributes have to be considered. Artificial intelligent (AI) techniques can be employed to monitor and evaluate the ozone concentration level. The aim of this study is to develop an Adaptive Neuro-Fuzzy inference approach (ANFIS) to determine the influence of peripheral factors on air quality and pollution which is an arising problem due to ozone level in Jeddah city. The concentration of ozone level was considered as a factor to predict the Air Quality (AQ) under the atmospheric conditions. Using Air Quality Standards of Saudi Arabia, ozone concentration level was modelled by employing certain factors such as; nitrogen oxide (NOx), atmospheric pressure, temperature, and relative humidity. Hence, an ANFIS model was developed to observe the ozone concentration level and the model performance was assessed by testing data obtained from the monitoring stations established by the General Authority of Meteorology and Environment Protection of Kingdom of Saudi Arabia. The outcomes of ANFIS model were re-assessed by fuzzy quality charts using quality specification and control limits based on US-EPA air quality standards. The results of present study show that the ANFIS model is a comprehensive approach for the estimation and assessment of ozone level and is a reliable approach to produce more genuine outcomes.
Scanning electron microscope image signal-to-noise ratio monitoring for micro-nanomanipulation.
Marturi, Naresh; Dembélé, Sounkalo; Piat, Nadine
2014-01-01
As an imaging system, scanning electron microscope (SEM) performs an important role in autonomous micro-nanomanipulation applications. When it comes to the sub micrometer range and at high scanning speeds, the images produced by the SEM are noisy and need to be evaluated or corrected beforehand. In this article, the quality of images produced by a tungsten gun SEM has been evaluated by quantifying the level of image signal-to-noise ratio (SNR). In order to determine the SNR, an efficient and online monitoring method is developed based on the nonlinear filtering using a single image. Using this method, the quality of images produced by a tungsten gun SEM is monitored at different experimental conditions. The derived results demonstrate the developed method's efficiency in SNR quantification and illustrate the imaging quality evolution in SEM. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Alameddine, Ibrahim; Karmakar, Subhankar; Qian, Song S.; Paerl, Hans W.; Reckhow, Kenneth H.
2013-10-01
The total maximum daily load program aims to monitor more than 40,000 standard violations in around 20,000 impaired water bodies across the United States. Given resource limitations, future monitoring efforts have to be hedged against the uncertainties in the monitored system, while taking into account existing knowledge. In that respect, we have developed a hierarchical spatiotemporal Bayesian model that can be used to optimize an existing monitoring network by retaining stations that provide the maximum amount of information, while identifying locations that would benefit from the addition of new stations. The model assumes the water quality parameters are adequately described by a joint matrix normal distribution. The adopted approach allows for a reduction in redundancies, while emphasizing information richness rather than data richness. The developed approach incorporates the concept of entropy to account for the associated uncertainties. Three different entropy-based criteria are adopted: total system entropy, chlorophyll-a standard violation entropy, and dissolved oxygen standard violation entropy. A multiple attribute decision making framework is adopted to integrate the competing design criteria and to generate a single optimal design. The approach is implemented on the water quality monitoring system of the Neuse River Estuary in North Carolina, USA. The model results indicate that the high priority monitoring areas identified by the total system entropy and the dissolved oxygen violation entropy criteria are largely coincident. The monitoring design based on the chlorophyll-a standard violation entropy proved to be less informative, given the low probabilities of violating the water quality standard in the estuary.
ERIC Educational Resources Information Center
Coates, Hamish
2009-01-01
Vocational education and training plays a major and increasing role in developing the knowledge and skills that underpin Australia's economy and society. It is vital, accordingly, that training outcomes are of high quality. This paper reports work undertaken to develop a new evidence-based and outcomes-focused national approach to monitoring and…
A compact CCD-monitored atomic force microscope with optical vision and improved performances.
Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang
2013-09-01
A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Bieroza, Magdalena
2017-04-01
High-frequency nutrient (phosphorus and nitrogen) monitoring using wet-chemistry analysers and optical sensors has revolutionised the collection of biogeochemical data from streams, rivers and lakes. Matching the nutrient measurement time with timescales of hydrological responses has revealed biogeochemical patterns and nutrient hydrological responses not observed previously. Capturing a wider range of nutrient concentrations compared to traditional coarse resolution sampling enables more accurate estimation of mean concentrations and loads and thus improved water body classification. However, to date the scientific insights from the high-frequency nutrient monitoring studies have not been translated into policy and operational responses. The pertinent question is where and how often to measure nutrients to satisfy statutory monitoring requirements for the Water Framework Directive and the Nitrates Directive. Therefore this paper discusses how the reduced data uncertainty and improved process understanding obtained with the high-frequency measurements can improve statutory nutrient monitoring, using case studies from England and Sweden.
Kalali, Amir; West, Mark; Walling, David; Hilt, Dana; Engelhardt, Nina; Alphs, Larry; Loebel, Antony; Vanover, Kim; Atkinson, Sarah; Opler, Mark; Sachs, Gary; Nations, Kari; Brady, Chris
2016-01-01
This paper summarizes the results of the CNS Summit Data Quality Monitoring Workgroup analysis of current data quality monitoring techniques used in central nervous system (CNS) clinical trials. Based on audience polls conducted at the CNS Summit 2014, the panel determined that current techniques used to monitor data and quality in clinical trials are broad, uncontrolled, and lack independent verification. The majority of those polled endorse the value of monitoring data. Case examples of current data quality methodology are presented and discussed. Perspectives of pharmaceutical companies and trial sites regarding data quality monitoring are presented. Potential future developments in CNS data quality monitoring are described. Increased utilization of biomarkers as objective outcomes and for patient selection is considered to be the most impactful development in data quality monitoring over the next 10 years. Additional future outcome measures and patient selection approaches are discussed. PMID:27413584
ERIC Educational Resources Information Center
Australian Council for Educational Research, 2015
2015-01-01
Monitoring Trends in Educational Growth (MTEG) offers a flexible, collaborative approach to developing and implementing an assessment of learning outcomes that yields high-quality, nationally relevant data. MTEG is a service that involves ACER staff working closely with each country to develop an assessment program that meets the country's…
Chen, Sheng-Po; Wang, Chieh-Heng; Lin, Wen-Dian; Tong, Yu-Huei; Chen, Yu-Chun; Chiu, Ching-Jui; Chiang, Hung-Chi; Fan, Chen-Lun; Wang, Jia-Lin; Chang, Julius S
2018-05-01
The present study combines high-resolution measurements at various distances from a world-class gigantic petrochemical complex with model simulations to test a method to assess industrial emissions and their effect on local air quality. Due to the complexity in wind conditions which were highly seasonal, the dominant wind flow patterns in the coastal region of interest were classified into three types, namely northeast monsoonal (NEM) flows, southwest monsoonal (SEM) flows and local circulation (LC) based on six years of monitoring data. Sulfur dioxide (SO 2 ) was chosen as an indicative pollutant for prominent industrial emissions. A high-density monitoring network of 12 air-quality stations distributed within a 20-km radius surrounding the petrochemical complex provided hourly measurements of SO 2 and wind parameters. The SO 2 emissions from major industrial sources registered by the monitoring network were then used to validate model simulations and to illustrate the transport of the SO 2 plumes under the three typical wind patterns. It was found that the coupling of observations and modeling was able to successfully explain the transport of the industrial plumes. Although the petrochemical complex was seemingly the only major source to affect local air quality, multiple prominent sources from afar also played a significant role in local air quality. As a result, we found that a more complete and balanced assessment of the local air quality can be achieved only after taking into account the wind characteristics and emission factors of a much larger spatial scale than the initial (20 km by 20 km) study domain. Copyright © 2018 Elsevier Ltd. All rights reserved.
Water-Quality Assessment of the High Plains Aquifer, 1999-2004
McMahon, Peter B.; Dennehy, Kevin F.; Bruce, Breton W.; Gurdak, Jason J.; Qi, Sharon L.
2007-01-01
Water quality of the High Plains aquifer was assessed for the period 1999-2004 as part of the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program. This effort represents the first systematic regional assessment of water quality in this nationally important aquifer. A stratified, nested group of studies was designed to assess linkages between the quality of water recharging the aquifer, the effect of transport through the hydrologic system on water quality, and the quality of the resource used for human consumption and agricultural applications. The stratified, nested design facilitated upscaling of monitoring results to unmonitored areas of the aquifer as well as upscaling of process understanding from local to regional scales.
Water monitor system: Phase 1 test report
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.
1976-01-01
Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.
NASA Astrophysics Data System (ADS)
Mattacchioni, A.; Cristianini, M.; Lo Bosco, A.
2013-03-01
The purpose of this paper is to project digital rectangular phantoms, Di.Recta Multipurpose Phantoms (Di.Recta MP) for quality controls of primary high resolution medical monitors. The first approach for the monitors quality evaluation is represented by AAPM tests using multipurpose TG-18- CQ phantoms. The TG18-QC patterns are available in two sizes: 1024x1024 and 2048x2048 and the use of these phantoms requires a correct monitor setup. The study demonstrates that this type of phantoms is suitable for CRT monitors with adequate settings procedures. In the second step LCD monitors are analysed. Different types of primary monitors are included in a range between 2 and 5 Mp. The difference between the resolution of monitors and phantoms does not allow a complete analysis of the entire system, just moving phantoms in different positions. Of course, the analysis of images in the peripheral regions of medical monitors can not be neglected, especially because of the possible legal implications. A simpler analysis of these areas can be done through the use of rectangular phantoms in place of square ones. Furthermore, because of different technology, also different analysis patches are necessary for these types of monitors. Therefore, there are proposed digital rectangular phantoms, Di.Recta MP, compatible with the spatial resolution of most of commercial monitors. These phantoms are designed to simulate typical radiological conditions to determine the presence of significant defects using appropriate patches such as luminance, contrast, noise patterns. Finally a preliminary study of dedicate Di.Recta MP are proposed for LED monitors.
Square2 - A Web Application for Data Monitoring in Epidemiological and Clinical Studies
Schmidt, Carsten Oliver; Krabbe, Christine; Schössow, Janka; Albers, Martin; Radke, Dörte; Henke, Jörg
2017-01-01
Valid scientific inferences from epidemiological and clinical studies require high data quality. Data generating departments therefore aim to detect data irregularities as early as possible in order to guide quality management processes. In addition, after the completion of data collections the obtained data quality must be evaluated. This can be challenging in complex studies due to a wide scope of examinations, numerous study variables, multiple examiners, devices, and examination centers. This paper describes a Java EE web application used to monitor and evaluate data quality in institutions with complex and multiple studies, named Square 2 . It uses the Java libraries Apache MyFaces 2, extended by BootsFaces for layout and style. RServe and REngine manage calls to R server processes. All study data and metadata are stored in PostgreSQL. R is the statistics backend and LaTeX is used for the generation of print ready PDF reports. A GUI manages the entire workflow. Square 2 covers all steps in the data monitoring workflow, including the setup of studies and their structure, the handling of metadata for data monitoring purposes, selection of variables, upload of data, statistical analyses, and the generation as well as inspection of quality reports. To take into account data protection issues, Square 2 comprises an extensive user rights and roles concept.
NASA Astrophysics Data System (ADS)
Schloss, J. A.
2012-12-01
The New Hampshire Lakes Lay Monitoring Program was originally designed by faculty at the University of New Hampshire in 1979 to provide the capacity to better monitor for long-term lake water quality changes and trends. As participants became educated, empowered and engaged the program soon evolved to also become a participatory research enterprise. This resulted in not only providing useful information for informed local stewardship and protection at the local level but also for state and region-wide decision-making, state and federal assessments/reporting and advancing our understanding of lake and watershed science. Our successes and failures have been more dependent on understanding the particular human dimensions that influence our volunteers and less to do with the typical project management, quality assurance, and communication concerns we typically deal with in professional based research efforts. Our participants are extremely diverse in terms of their life experiences, interests and motivations so the key to long-term commitment and high quality participation is understanding the difference between a citizen monitor and your archetypical research technician or student. This presentation will highlight some important lessons learned on how to involve various types of volunteers from school groups to retirees, as well as particular approaches and concerns regarding program management, retention, quality control and communications.
Spence, Porché L
2015-01-01
Caffeine has been suggested as a chemical indicator for domestic wastewater in freshwater systems, although it is not included in water quality monitoring programs. The Third Fork Creek watershed in Durham, NC, is highly urbanized, with a history of receiving untreated wastewater from leaking and overflowing sanitary sewers. The poor water quality originating in the Third Fork Creek watershed threatens its intended uses and jeopardizes drinking water, aquatic life, and recreational activities provided by Jordan Lake. Organic waste contaminants have been detected in both Third Fork Creek watershed and Jordan Lake; however, the sampling periods were temporary, resulting in a few samples collected during nonstorm periods. It is recommended that (1) the concentration of caffeine and other organic waste contaminants are determined during storm and nonstorm periods and (2) caffeine is monitored regularly with traditional water quality indicators to evaluate the health of Third Fork Creek watershed. PMID:26157335
Rapid underway profiling of water quality in Queensland estuaries.
Hodge, Jonathan; Longstaff, Ben; Steven, Andy; Thornton, Phillip; Ellis, Peter; McKelvie, Ian
2005-01-01
We present an overview of a portable underway water quality monitoring system (RUM-Rapid Underway Monitoring), developed by integrating several off-the-shelf water quality instruments to provide rapid, comprehensive, and spatially referenced 'snapshots' of water quality conditions. We demonstrate the utility of the system from studies in the Northern Great Barrier Reef (Daintree River) and the Moreton Bay region. The Brisbane dataset highlights RUM's utility in characterising plumes as well as its ability to identify the smaller scale structure of large areas. RUM is shown to be particularly useful when measuring indicators with large small-scale variability such as turbidity and chlorophyll-a. Additionally, the Daintree dataset shows the ability to integrate other technologies, resulting in a more comprehensive analysis, whilst sampling offshore highlights some of the analytical issues required for sampling low concentration data. RUM is a low cost, highly flexible solution that can be modified for use in any water type, on most vessels and is only limited by the available monitoring technologies.
Brown, Juliane B.
2008-01-01
Historical water-quality data in the National Park Service Southern Colorado Plateau Network have been collected irregularly and with little followup interpretation, restricting the value of the data. To help address these issues, to inform future water-quality monitoring planning efforts, and to address relevant National Park Service Inventory and Monitoring Program objectives, the U.S. Geological Survey, in cooperation with the National Park Service, compiled, reviewed, and summarized available historical water-quality data for 19 park units in the Southern Colorado Plateau Network. The data are described in terms of availability by major water-quality classes, park unit, site type, and selected identified water sources. The report also describes the geology, water resources, water-quality issues, data gaps, and water-quality standard exceedances identified in five of the park units determined to be of high priority. The five park units are Bandelier National Monument in New Mexico, Canyon de Chelly National Monument in Arizona, Chaco Culture National Historical Park in New Mexico, Glen Canyon National Recreation Area in Arizona and Utah, and Mesa Verde National Park in Colorado. Statistical summaries of water-quality characteristics are presented and considerations for future water-quality monitoring are provided for these five park units.
NASA Astrophysics Data System (ADS)
Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nemuc, Anca; Stachlewska, Iwona; Zehner, Claus
2017-04-01
We present a summary and some first results of a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellite instruments, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. The primary goal of SAMIRA is to demonstrate the usefulness of existing and future satellite products of air quality for improving monitoring and mapping of air pollution at the regional scale. A total of six core activities are being carried out in order to achieve this goal: Firstly, the project is developing and optimizing algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from the Spinning Enhanced Visible and InfraRed Imager (SEVIRI) onboard of Meteosat Second Generation. As a second activity, SAMIRA aims to derive particulate matter (PM2.5) estimates from AOD data by developing robust algorithms for AOD-to-PM conversion with the support from model- and Lidar data. In a third activity, we evaluate the added value of satellite products of atmospheric composition for operational European-scale air quality mapping using geostatistics and auxiliary datasets. The additional benefit of satellite-based monitoring over existing monitoring techniques (in situ, models) is tested by combining these datasets using geostatistical methods and demonstrated for nitrogen dioxide (NO2), sulphur dioxide (SO2), and aerosol optical depth/particulate matter. As a fourth activity, the project is developing novel algorithms for downscaling coarse-resolution satellite products of air quality with the help of high-resolution model information. This will add value to existing earth observation products of air quality by bringing them to spatial scales that are more in line with what is generally required for studying urban and regional scale air quality. In a fifth activity, we implement robust and independent validation schemes for evaluating the quality of the generated products. Finally, in a sixth activity the consortium is working towards a pre-operational system for improved PM forecasts using observational (in situ and satellite) data assimilation. SAMIRA aims to maximize project benefits by liaison with national and regional environmental protection agencies and health institutions, as well as related ESA and European initiatives such as the Copernicus Atmosphere Monitoring Service (CAMS).
Water quality assessment of a small peri-urban river using low and high frequency monitoring.
Ivanovsky, A; Criquet, J; Dumoulin, D; Alary, C; Prygiel, J; Duponchel, L; Billon, G
2016-05-18
The biogeochemical behaviors of small rivers that pass through suburban areas are difficult to understand because of the multi-origin inputs that can modify their behavior. In this context, a monitoring strategy has been designed for the Marque River, located in Lille Metropolitan area of northern France, that includes both low-frequency monitoring over a one-year period (monthly sampling) and high frequency monitoring (measurements every 10 minutes) in spring and summer. Several environmental and chemical parameters are evaluated including rainfall events, river flow, temperature, dissolved oxygen, turbidity, conductivity, nutritive salts and dissolved organic matter. Our results from the Marque River show that (i) it is impacted by both urban and agricultural inputs, and as a consequence, the concentrations of phosphate and inorganic nitrogen have degraded the water quality; (ii) the classic photosynthesis/respiration processes are disrupted by the inputs of organic matter and nutritive salts; (iii) during dry periods, the urban sewage inputs (treated or not) are more important during the day, as indicated by higher river flows and maximal concentrations of ammonium; (iv) phosphate concentrations depend on oxygen contents in the river; (v) high nutrient concentrations result in eutrophication of the Marque River with lower pH and oxygen concentrations in summer. During rainfalls, additional inputs of ammonium, biodegradable organic matter as well as sediment resuspension result in anoxic events; and finally (vi) concentrations of nitrate are approximately constant over the year, except in winter when higher inputs can be recorded. Having better identified the processes responsible for the observed water quality, a more informed remediation effort can be put forward to move this suburban river to a good status of water quality.
Playing Chemical Plant Environmental Protection Games with Historical Monitoring Data
Reniers, Genserik; Zhang, Laobing; Qiu, Xiaogang
2017-01-01
The chemical industry is very important for the world economy and this industrial sector represents a substantial income source for developing countries. However, existing regulations on controlling atmospheric pollutants, and the enforcement of these regulations, often are insufficient in such countries. As a result, the deterioration of surrounding ecosystems and a quality decrease of the atmospheric environment can be observed. Previous works in this domain fail to generate executable and pragmatic solutions for inspection agencies due to practical challenges. In addressing these challenges, we introduce a so-called Chemical Plant Environment Protection Game (CPEP) to generate reasonable schedules of high-accuracy air quality monitoring stations (i.e., daily management plans) for inspection agencies. First, so-called Stackelberg Security Games (SSGs) in conjunction with source estimation methods are applied into this research. Second, high-accuracy air quality monitoring stations as well as gas sensor modules are modeled in the CPEP game. Third, simplified data analysis on the regularly discharging of chemical plants is utilized to construct the CPEP game. Finally, an illustrative case study is used to investigate the effectiveness of the CPEP game, and a realistic case study is conducted to illustrate how the models and algorithms being proposed in this paper, work in daily practice. Results show that playing a CPEP game can reduce operational costs of high-accuracy air quality monitoring stations. Moreover, evidence suggests that playing the game leads to more compliance from the chemical plants towards the inspection agencies. Therefore, the CPEP game is able to assist the environmental protection authorities in daily management work and reduce the potential risks of gaseous pollutants dispersion incidents. PMID:28961188
Ye, Bixiong; E, Xueli; Zhang, Lan
2015-01-01
To optimize non-regular drinking water quality indices (except Giardia and Cryptosporidium) of urban drinking water. Several methods including drinking water quality exceed the standard, the risk of exceeding standard, the frequency of detecting concentrations below the detection limit, water quality comprehensive index evaluation method, and attribute reduction algorithm of rough set theory were applied, redundancy factor of water quality indicators were eliminated, control factors that play a leading role in drinking water safety were found. Optimization results showed in 62 unconventional water quality monitoring indicators of urban drinking water, 42 water quality indicators could be optimized reduction by comprehensively evaluation combined with attribute reduction of rough set. Optimization of the water quality monitoring indicators and reduction of monitoring indicators and monitoring frequency could ensure the safety of drinking water quality while lowering monitoring costs and reducing monitoring pressure of the sanitation supervision departments.
Ambient Monitoring Technology Information Center (AMTIC)
This site contains information on ambient air quality monitoring programs, monitoring methods, quality assurance and control procedures, and federal regulations related to ambient air quality monitoring.
Cell-based in vitro assays show promise for water quality monitoring applications due to high sensitivity, the ability to quantitatively detect a biologically relevant effect endpoint such as receptor transactivation (i.e., effect-based monitoring), and the ability to assess comp...
Well-characterized and standardized methods are the foundation upon which monitoring of regulated and unregulated contaminants in drinking water are based. To obtain reliable, high quality data for trace analysis of contaminants, these methods must be rugged, selective and sensit...
Improved head-controlled TV system produces high-quality remote image
NASA Technical Reports Server (NTRS)
Goertz, R.; Lindberg, J.; Mingesz, D.; Potts, C.
1967-01-01
Manipulator operator uses an improved resolution tv camera/monitor positioning system to view the remote handling and processing of reactive, flammable, explosive, or contaminated materials. The pan and tilt motions of the camera and monitor are slaved to follow the corresponding motions of the operators head.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
... Proposed United States Regional Climate Reference Network (USRCRN) AGENCY: National Weather Service (NWS..., is proposing to implement, operate, and manage a USRCRN. With other climate monitoring efforts..., high-quality climate data for use in climate-monitoring activities and for placing current climate...
Water Quality Analysis of Yosemite Creek Watershed, San Francisco, California
NASA Astrophysics Data System (ADS)
Davis, J. R.; Snow, M. K.; Aquino, A.; Huang, C.; Thai, A.; Yuen, C.
2003-12-01
Surface water quality in urban settings can become contaminated by anthropogenic inputs. Yosemite Creek watershed is situated on the east side of San Francisco near Bayview Hunters Point and provides an ideal location for water quality investigations in urban environments. Accordingly, students from Philip and Sala Burton High School monitored water quality at three locations for their physicochemical and biological characteristics. Water was tested for pH, dissolved oxygen, conductivity, total dissolved solids, salinity, and oxidation reduction potential. In addition, a Hach DR 850 digital colorimeter was utilized to measure chlorine, fluorine, nitrogen, phosphorous, and sulfate. The biological component was assessed via monitoring benthic macro invertebrates. Specifically, the presence of caddisfly (Trichoptera) were used to indicate low levels of contaminants and good water quality. Our results indicate that water quality and macro invertebrate populations varied spatially within the watershed. Further investigation is needed to pinpoint the precise location of contaminant inputs.
Rio Bauta Abajo, Orocovis, Puerto Rico Monitoring: Citizen Science in Action
NASA Astrophysics Data System (ADS)
Rivera, L. D.; Rodriguez, C.
2015-12-01
"Conoce tu rio" (Learn about your river) is a Citizen Science-"Para La Naturaleza" Project with the purpose of providing citizens effective monitoring methods for water quality and macro invertebrates. Through the monthly monitoring of Rio Grande de Manatí watershed in Puerto Rico, volunteers gained the knowledge and skills necessary to conduct the same methodology in other rivers of Puerto Rico. This is the case of the Rio Bauta Abajo-Orocovis group, initiated by a volunteer of "Conoce tu Rio". The new group has the objective of monitoring the water quality, shrimps and other macro invertebrate diversity and abundance in a stream reach of Rio Bauta Abajo, Orocovis, Puerto Rico. The group is also part of the EPA Equipment Loan Program for Pathogen and Water Quality Monitoring. Shrimps and macro invertebrates are captured using nets. In this ongoing project, preliminary results show that 5 of the 17 shrimp species of Puerto Rico and the freshwater crab have been captured in the monitoring point of Rio Bauta Abajo. The most abundant species captured was Atya scabra representing 70% of the abundance. The second most abundant species was Xiphocaris elongata representing 20% of the abundance. We also found a large number of gravid females of two shrimp species. Sixty percent of captured Atya scabra were gravid while 100% of the captured Xiphocaris elongata were gravid. Water quality is within the standard except for phosphorous and nitrogen. The most abundant species inhabit different habitats in the river. Atya scabra is found in the riffles and Xiphocaris elongata is found in the stream borders and or pools. The high number of gravid females suggests that the dry season is the reproductive season for this two species. The high concentration of phosphorous and nitrogen suggest that in the area there area either crops of animals facilities whose runoff is getting to the river. This monitoring group expects to continue motivating citizens to monitor the water quality in other rivers of Puerto Rico, to raise awareness about the conservation of the rivers and to disseminate the results of their study to the general public and the government agencies. Puerto Rico is suffering a drought and this is a critical moment to raise awareness about the conservation of the water resources and its flora and fauna.
[Monitoring evaluation system for high-specialty hospitals].
Fajardo Dolci, Germán; Aguirre Gas, Héctor G; Robledo Galván, Héctor
2011-01-01
Hospital evaluation is a fundamental process to identify medical units' objective compliance, to analyze efficiency of resource use and allocation, institutional values and mission alignment, patient safety and quality standards, contributions to research and medical education, and the degree of coordination among medical units and the health system as a whole. We propose an evaluation system for highly specialized regional hospitals through the monitoring of performance indicators. The following are established as base thematic elements in the construction of indicators: safe facilities and equipment, financial situation, human resources management, policy management, organizational climate, clinical activity, quality and patient safety, continuity of care, patients' and providers' rights and obligations, teaching, research, social responsibility, coordination mechanisms. Monitoring refers to the planned and systematic evaluation of valid and reliable indicators, aimed at identifying problems and opportunity areas. Moreover, evaluation is a powerful tool to strengthen decision-making and accountability in medical units.
NASA Astrophysics Data System (ADS)
Hufenbach, W.; Gude, M.; Czulak, A.; Kretschmann, Martin
2014-04-01
Increasing economic, political and ecological pressure leads to steadily rising percentage of modern processing and manufacturing processes for fibre reinforced polymers in industrial batch production. Component weights beneath a level achievable by classic construction materials, which lead to a reduced energy and cost balance during product lifetime, justify the higher fabrication costs. However, complex quality control and failure prediction slow down the substitution by composite materials. High-resolution fibre-optic sensors (FOS), due their low diameter, high measuring point density and simple handling, show a high applicability potential for an automated sensor-integration in manufacturing processes, and therefore the online monitoring of composite products manufactured in industrial scale. Integrated sensors can be used to monitor manufacturing processes, part tests as well as the component structure during product life cycle, which simplifies allows quality control during production and the optimization of single manufacturing processes.[1;2] Furthermore, detailed failure analyses lead to a enhanced understanding of failure processes appearing in composite materials. This leads to a lower wastrel number and products of a higher value and longer product life cycle, whereby costs, material and energy are saved. This work shows an automation approach for FOS-integration in the braiding process. For that purpose a braiding wheel has been supplemented with an appliance for automatic sensor application, which has been used to manufacture preforms of high-pressure composite vessels with FOS-networks integrated between the fibre layers. All following manufacturing processes (vacuum infiltration, curing) and component tests (quasi-static pressure test, programmed delamination) were monitored with the help of the integrated sensor networks. Keywords: SHM, high-pressure composite vessel, braiding, automated sensor integration, pressure test, quality control, optic-fibre sensors, Rayleigh, Luna Technologies
Contact and non-contact ultrasonic measurement in the food industry: a review
NASA Astrophysics Data System (ADS)
Taufiq Mohd Khairi, Mohd; Ibrahim, Sallehuddin; Yunus, Mohd Amri Md; Faramarzi, Mahdi
2016-01-01
The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated.
Setting standards and monitoring quality in the NHS 1999-2013: a classic case of goal conflict.
Littlejohns, Peter; Knight, Alec; Littlejohns, Anna; Poole, Tara-Lynn; Kieslich, Katharina
2017-04-01
2013 saw the National Health Service (NHS) in England severely criticized for providing poor quality despite successive governments in the previous 15 years, establishing a range of new institutions to improve NHS quality. This study seeks to understand the contributions of political and organizational influences in enabling the NHS to deliver high-quality care through exploring the experiences of two of the major new organizations established to set standards and monitor NHS quality. We used a mixed method approach: first a cross-sectional, in-depth qualitative interview study and then the application of principal agent modeling (Waterman and Meier broader framework). Ten themes were identified as influencing the functioning of the NHS regulatory institutions: socio-political environment; governance and accountability; external relationships; clarity of purpose; organizational reputation; leadership and management; organizational stability; resources; organizational methods; and organizational performance. The organizations could be easily mapped onto the framework, and their transience between the different states could be monitored. We concluded that differing policy objectives for NHS quality monitoring resulted in central involvement and organizational change. This had a disruptive effect on the ability of the NHS to monitor quality. Constant professional leadership, both clinical and managerial, and basing decisions on best evidence, both technical and organizational, helped one institution to deliver on its remit, even within a changing political/policy environment. Application of the Waterman-Meier framework enabled an understanding and description of the dynamic relationship between central government and organizations in the NHS and may predict when tensions will arise in the future. © 2016 The Authors. The International Journal of Health Planning and Management Published by John Wiley & Sons Ltd. © 2016 The Authors. The International Journal of Health Planning and Management Published by John Wiley & Sons Ltd.
End-user perspective of low-cost sensors for outdoor air pollution monitoring.
Rai, Aakash C; Kumar, Prashant; Pilla, Francesco; Skouloudis, Andreas N; Di Sabatino, Silvana; Ratti, Carlo; Yasar, Ansar; Rickerby, David
2017-12-31
Low-cost sensor technology can potentially revolutionise the area of air pollution monitoring by providing high-density spatiotemporal pollution data. Such data can be utilised for supplementing traditional pollution monitoring, improving exposure estimates, and raising community awareness about air pollution. However, data quality remains a major concern that hinders the widespread adoption of low-cost sensor technology. Unreliable data may mislead unsuspecting users and potentially lead to alarming consequences such as reporting acceptable air pollutant levels when they are above the limits deemed safe for human health. This article provides scientific guidance to the end-users for effectively deploying low-cost sensors for monitoring air pollution and people's exposure, while ensuring reasonable data quality. We review the performance characteristics of several low-cost particle and gas monitoring sensors and provide recommendations to end-users for making proper sensor selection by summarizing the capabilities and limitations of such sensors. The challenges, best practices, and future outlook for effectively deploying low-cost sensors, and maintaining data quality are also discussed. For data quality assurance, a two-stage sensor calibration process is recommended, which includes laboratory calibration under controlled conditions by the manufacturer supplemented with routine calibration checks performed by the end-user under final deployment conditions. For large sensor networks where routine calibration checks are impractical, statistical techniques for data quality assurance should be utilised. Further advancements and adoption of sophisticated mathematical and statistical techniques for sensor calibration, fault detection, and data quality assurance can indeed help to realise the promised benefits of a low-cost air pollution sensor network. Copyright © 2017 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... based on complete, quality-assured and certified ambient air quality monitoring data for 2007-2009... certain air quality monitoring data because they meet the criteria for ozone exceptional events that are... certified monitoring data. A violation occurs when the ambient ozone air quality monitoring data show...
NASA Technical Reports Server (NTRS)
Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Minton, John M.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.
2014-01-01
Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.
[National health resources for highly specialised medicine].
Bratlid, Dag; Rasmussen, Knut
2005-11-03
In order to monitor quality and efficiency in the use of health resources for highly specialised medicine, a National Professional Council has since 1990 advised the Norwegian health authorities on the establishing and localisation of such services. A comprehensive review of both the quality, economy and the geographical distribution of patients in each specialised service has been carried out. 33 defined national programmes were centralised to one hospital only and distributed among seven university hospitals. Eight multiregional programmes were centralised to two hospitals only and included four university hospitals. In 2001, a total of 2711 new patients were treated in these programmes. The system seems to have secured a sufficient patient flow to each programme so as to maintain quality. However, a geographically skewed distribution of patients was noted, particularly in some of the national programmes. In a small country like Norway, with 4.5 million inhabitants, a centralised monitoring of highly specialised medicine seems both rational and successful. By the same logic, however, international cooperation should probably be sought for the smallest patient groups.
Zhao, Peng; Sun, Jian-Jun; Wu, Tai-Hu
2008-11-01
Real-time monitoring for temperature is required in cold chain for the medical products that are sensible with temperature, such as blood and bacterin, to guarantee the quality and reduce their wastage. This wireless monitoring system in cold chain is developed with Zigbee technology. Functions such as real-time monitoring, analyzing, alarming are realized. The system boasts such characteristics as low power consumption, low cost, big capacity and high reliability, and could improve the capability of real-time monitoring and management in cold chain effectively.
Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A
2014-12-01
High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ± 1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.
Classification management plan of groundwater quality in Taiwan
NASA Astrophysics Data System (ADS)
Chen, Chun Ming; Chen, Yu Ying; Pan, Shih Cheng; Li, Hui Jun; Hsiao, Fang Ke
2017-04-01
Taiwan Environmental Protection Administration has been monitoring regional water quality for 14 years. Since the beginning of 2002 till now, there are 453 regional groundwater monitoring wells in ten groundwater subregions in Taiwan, and the monitoring of groundwater quality has been carried out for a long time. Currently, water quality monitoring project has reached 50 items, while the number of water quality monitoring data has reached more than 20,000. In order to use the monitoring data efficiently, this study constructed the localized groundwater quality indicators of Taiwan. This indicator takes into account the different users' point of view, incorporating the Taiwan groundwater pollution monitoring standards (Category II), irrigation water quality standard and drinking water source water quality standard. 50 items of water quality monitoring projects were simplified and classified. The groundwater quality parameters were divided into five items, such as potability for drinking water, salting, external influence, health influences and toxicity hazard. The weight of the five items of groundwater was calculated comprehensively, and the groundwater quality of each monitoring well was evaluated with three grades of good, ordinary, and poor. According to the monitoring results of the groundwater monitoring wells in October to December of 2016, about 70% of groundwater quality in Taiwan is in good to ordinary grades. The areas with poor groundwater quality were mostly distributed in coastal, agriculture and part of the urban areas. The conductivity or ammonia nitrogen concentration was higher in those regions, showing that groundwater may be salinized or affected by external influences. Groundwater quality indicators can clearly show the current comprehensive situation of the groundwater environment in Taiwan and can be used as a tool for groundwater quality classification management. The indicators can coordinate with the Taiwan land planning policy in the future, and will be able to effectively grasp the changes of the national sub-regional environmental resources, which can serve as one of the important references in national land zoning according to environmental resources. Keywords: Groundwater Quality Indicators, Groundwater Quality Classification management
Sim, L; Manthey, K; Stuckey, S
2007-06-01
A study to compare performance of the following display monitors for application as PACS CR diagnostic workstations is described. 1. Diagnostic quality, 3 Mega Pixel, 21 inch monochrome LCD monitors--Planar C3i. 2. Clinical review quality, 2 Mega Pixel, 21 inch colour LCD monitors--Planar PX212. Two sets of seventy radiological studies were presented to four senior radiologists on two occasions, using different displays on each occasion. The clinical condition used for this investigation was to query for the presence of a solitary pulmonary nodule. Receiver Operating Characteristic (ROC) curves were constructed for diagnostic performance for each presentation. Areas under the ROC curves (AUC) for diagnosis using different monitors were compared and the following results obtained: Monochrome AUC = 0.813 +/- 0.02, Colour AUC = 0.801 +/- 0.021. These results indicate that there is no statistically significant difference in the performance of these monitor types at a 95% confidence level.
High-Density, High-Resolution, Low-Cost Air Quality Sensor Networks for Urban Air Monitoring
NASA Astrophysics Data System (ADS)
Mead, M. I.; Popoola, O. A.; Stewart, G.; Bright, V.; Kaye, P.; Saffell, J.
2012-12-01
Monitoring air quality in highly granular environments such as urban areas which are spatially heterogeneous with variable emission sources, measurements need to be made at appropriate spatial and temporal scales. Current routine air quality monitoring networks generally are either composed of sparse expensive installations (incorporating e.g. chemiluminescence instruments) or higher density low time resolution systems (e.g. NO2 diffusion tubes). Either approach may not accurately capture important effects such as pollutant "hot spots" or adequately capture spatial (or temporal) variability. As a result, analysis based on data from traditional low spatial resolution networks, such as personal exposure, may be inaccurate. In this paper we present details of a sophisticated, low-cost, multi species (gas phase, speciated PM, meteorology) air quality measurement network methodology incorporating GPS and GPRS which has been developed for high resolution air quality measurements in urban areas. Sensor networks developed in the Centre for Atmospheric Science (University of Cambridge) incorporated electrochemical gas sensors configured for use in urban air quality studies operating at parts-per-billion (ppb) levels. It has been demonstrated that these sensors can be used to measure key air quality gases such as CO, NO and NO2 at the low ppb mixing ratios present in the urban environment (estimated detection limits <4ppb for CO and NO and <1ppb for NO2. Mead et al (submitted Aug., 2012)). Based on this work, a state of the art multi species instrument package for deployment in scalable sensor networks has been developed which has general applicability. This is currently being employed as part of a major 3 year UK program at London Heathrow airport (the Sensor Networks for Air Quality (SNAQ) Heathrow project). The main project outcome is the creation of a calibrated, high spatial and temporal resolution data set for O3, NO, NO2, SO2, CO, CO2, VOCstotal, size-speciated PM, temperature, relative humidity, wind speed and direction. The network incorporates existing GPRS infrastructures for real time sending of data with low overheads in terms of cost, effort and installation. In this paper we present data from the SNAQ Heathrow project as well as previous deployments showing measurement capability at the ppb level for NO, NO2 and CO. We show that variability can be observed and measured quantitatively using these sensor networks over widely differing time scales from individual emission events, diurnal variability associated with traffic and meteorological conditions, through to longer term synoptic weather conditions and seasonal behaviour. This work demonstrates a widely applicable generic capability to urban areas, airports as well as other complex emissions environments making this sensor system methodology valuable for scientific, policy and regulatory issues. We conclude that the low-cost high-density network philosophy has the potential to provide a more complete assessment of the high-granularity air quality structure generally observed in the environment. Further, when appropriately deployed, has the potential to offer a new paradigm in air quality quantification and monitoring.
NASA Astrophysics Data System (ADS)
McMillan, Lindsay A.; Rivett, Michael O.; Wealthall, Gary P.; Zeeb, Peter; Dumble, Peter
2018-03-01
Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation.
Amodio, M; Dambruoso, P R; de Gennaro, Gianluigi; de Gennaro, L; Loiotile, A Demarinis; Marzocca, A; Stasi, F; Trizio, L; Tutino, M
2014-12-01
In order to assess indoor air quality (IAQ), two 1-week monitoring campaigns of volatile organic compounds (VOC) were performed in different areas of a multistorey shopping mall. High-spatial-resolution monitoring was conducted at 32 indoor sites located in two storehouses and in different departments of a supermarket. At the same time, VOC concentrations were monitored in the mall and parking lot area as well as outdoors. VOC were sampled at 48-h periods using diffusive samplers suitable for thermal desorption. The samples were then analyzed with gas chromatography-mass spectrometry (GC-MS). The data analysis and chromatic maps indicated that the two storehouses had the highest VOC concentrations consisting principally of terpenes. These higher TVOC concentrations could be a result of the low efficiency of the air exchange and intake systems, as well as the large quantity of articles stored in these small spaces. Instead, inside the supermarket, the food department was the most critical area for VOC concentrations. To identify potential emission sources in this department, a continuous VOC analyzer was used. The findings indicated that the highest total VOC concentrations were present during cleaning activities and that these activities were carried out frequently in the food department. The study highlights the importance of conducting both high-spatial-resolution monitoring and high-temporal-resolution monitoring. The former was able to identify critical issues in environments with a complex emission scenario while the latter was useful in interpreting the dynamics of each emission source.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solis, R.P.; Chavez, F.C.; Garcia, S.E.
1997-12-31
In any operating geothermal power plant, steam quality is one of the most important parameters being monitored. In the Bacon-Manito Geothermal Production Field (BGPF), an online steam quality monitoring system have been installed in two operating power plants which provides an accurate, efficient and continuous real-time data which is more responsive to the various requirements of the field operation. The system utilizes sodium as an indicator of steam purity. Sodium concentration is read by the flame photometer located at the interface after aspirating a sample of the condensed steam through a continuous condensate sampler. The condensate has been degassed throughmore » a condensate-NCG separator. The flame photometer analog signal is then converted by a voltage-to-current converter/transmitter and relayed to the processor which is located at the control center through electrical cable to give a digital sodium concentration read-out at the control panel. The system features a high and high-high sodium level alarm, a continuous strip-chart recorder and a central computer for data capture, retrieval, and processing for further interpretation. Safety devices, such as the flame-off indicator at the control center and the automatic fuel cut-off device along the fuel line, are incorporated in the system.« less
John G. Kie; Timothy S. Burton
1984-01-01
Range managers need easily measured indices of dietary quality to ensure high quality forage for deer. Levels of fecal nitrogen and fecal 2,6 diaminopimelic acid, which have been suggested as such indices, were monitored for two herds of black-tailed deer (Odocoileus hemionus columbianus) in northern California. Both values were highest in summer...
An ultrasonic system for determining papaya physiological properties
NASA Astrophysics Data System (ADS)
Ibrahim, Sallehuddin; Ramli, Azlin; Yunus, Mohd Amri Md
2015-05-01
There is an increasing need for high quality fruit. As such it is important to have a fast, accurate and reliable method for measuring and monitoring the quality of fruit from the field to the consumer. This paper presents an investigation on the use of a non-destructive ultrasonic system which can be used to measure the quality of papaya.
40 CFR 52.346 - Air quality monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 52.346 - Air quality monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...
40 CFR 52.346 - Air quality monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...
40 CFR 52.346 - Air quality monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
40 CFR 52.346 - Air quality monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Air quality monitoring requirements. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.346 Air quality monitoring... VIII Administrator, the State submitted a revised Air Quality Monitoring State Implementation Plan. The...
40 CFR 51.190 - Ambient air quality monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Ambient air quality monitoring... PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Ambient Air Quality Surveillance § 51.190 Ambient air quality monitoring requirements. The requirements for monitoring ambient air...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...
MEMS device for mass market gas and chemical sensors
NASA Astrophysics Data System (ADS)
Kinkade, Brian R.; Daly, James T.; Johnson, Edward A.
2000-08-01
Gas and chemical sensors are used in many applications. Industrial health and safety monitors allow companies to meet OSHA requirements by detecting harmful levels of toxic or combustible gases. Vehicle emissions are tested during annual inspections. Blood alcohol breathalizers are used by law enforcement. Refrigerant leak detection ensures that the Earth's ozone layer is not being compromised. Industrial combustion emissions are also monitored to minimize pollution. Heating and ventilation systems watch for high levels of carbon dioxide (CO2) to trigger an increase in fresh air exchange. Carbon monoxide detectors are used in homes to prevent poisoning from poor combustion ventilation. Anesthesia gases are monitored during a patients operation. The current economic reality is that two groups of gas sensor technologies are competing in two distinct existing market segments - affordable (less reliable) chemical reaction sensors for consumer markets and reliable (expensive) infrared (IR) spectroscopic sensors for industrial, laboratory, and medical instrumentation markets. Presently high volume mass-market applications are limited to CO detectros and on-board automotive emissions sensors. Due to reliability problems with electrochemical sensor-based CO detectors there is a hesitancy to apply these sensors in other high volume applications. Applications such as: natural gas leak detection, non-invasive blood glucose monitoring, home indoor air quality, personal/portable air quality monitors, home fire/burnt cooking detector, and home food spoilage detectors need a sensor that is a small, efficient, accurate, sensitive, reliable, and inexpensive. Connecting an array of these next generation gas sensors to wireless networks that are starting to proliferate today creates many other applications. Asthmatics could preview the air quality of their destinations as they venture out into the day. HVAC systems could determine if fresh air intake was actually better than the air in the house. Internet grocery delivery services could check for spoiled foods in their clients' refrigerators. City emissions regulators could monitor the various emissions sources throughout the area from their desk to predict how many pollution vouchers they will need to trade in the next week. We describe a new component architecture for mass-market sensors based on silicon microelectromechanical systems (MEMS) technology. MEMS are micrometer-scale devices that can be fabricated as discrete devices or large arrays, using the technology of integrated circuit manufacturing. These new photonic bandgap and MEMS fabricataion technologies will simplify the component technology to provide high-quality gas and chemical sensors at consumer prices.
Applications of turbidity monitoring to forest management in California.
Harris, Richard R; Sullivan, Kathleen; Cafferata, Peter H; Munn, John R; Faucher, Kevin M
2007-09-01
Many California streams have been adversely affected by sedimentation caused by historic and current land uses, including timber harvesting. The impacts of timber harvesting and logging transportation systems on erosion and sediment delivery can be directly measured, modeled, or inferred from water quality measurements. California regulatory agencies, researchers, and land owners have adopted turbidity monitoring to determine effects of forest management practices on suspended sediment loads and water quality at watershed, project, and site scales. Watershed-scale trends in sediment discharge and responses to current forest practices may be estimated from data collected at automated sampling stations that measure turbidity, stream flow, suspended sediment concentrations, and other water quality parameters. Future results from these studies will provide a basis for assessing the effectiveness of modern forest practice regulations in protecting water quality. At the project scale, manual sampling of water column turbidity during high stream flow events within and downstream from active timber harvest plans can identify emerging sediment sources. Remedial actions can then be taken by managers to prevent or mitigate water quality impacts. At the site scale, manual turbidity sampling during storms or high stream flow events at sites located upstream and downstream from new, upgraded, or decommissioned stream crossings has proven to be a valuable way to determine whether measures taken to prevent post-construction erosion and sediment production are effective. Turbidity monitoring at the project and site scales is therefore an important tool for adaptive management. Uncertainty regarding the effects of current forest practices must be resolved through watershed-scale experiments. In the short term, this uncertainty will stimulate increased use of project and site-scale monitoring.
NASA Astrophysics Data System (ADS)
Adinolfi, M.; Archilli, F.; Baldini, W.; Baranov, A.; Derkach, D.; Panin, A.; Pearce, A.; Ustyuzhanin, A.
2017-10-01
Data quality monitoring, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the experimental apparatus during the data taking. DQM at LHCb is carried out in two phases. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs later. For the LHC Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator’s task, Monet is also equipped with an automated, fully configurable alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation over time.
Rapert, M I; Babakus, E
1996-01-01
Many organizations are not convinced a quality orientation pays off and are looking for ways to link quality with performance. The authors' exploratory study found that a quality orientation is a differentiating factor between low-performing and high-performing general service hospitals. They also developed a quality scale to assess the performance implications of quality-based strategies in the health care industry. Successful health care organizations (1) develop a strategic quality orientation at the management level, (2) support the pursuit of quality at the contact level, and (3) monitor external customers' perceptions of quality.
NASA Astrophysics Data System (ADS)
Levelt, P.; Veefkind, J. P.; Kleipool, Q.; Eskes, H.; A, R. V. D.; Mijling, B.; Tamminen, J.; Joiner, J.; Bhartia, P. K.
2015-12-01
In the last three decades the capabilities of measuring the atmospheric composition from space did grow tremendously with ESA's ENVISAT and NASA's Eos-Aura satellite programmes. The potential to operationally monitor the atmospheric composition, like the meteorological community is doing for the physical parameters, is now within reach. At the same time, the importance for society of operational environmental monitoring, related to the ozone layer, air quality and climate change, became apparent. The Ozone Monitoring Instrument (OMI), launched on board of NASA's EOS-Aura spacecraft in on July 15, 2004, provides unique contributions to air quality monitoring from Space. The combination of urban scale resolution (13 x 24 km2 in nadir) and daily global coverage proved to be key features for the air quality community. The OMI data is currently used for improving the air quality forecasts, for inverting high-resolution emission maps, for UV forecast and for volcanic plume warning systems for aviation. Due to its 11 year continuous operation OMI now provides the longest NO2 record from space, which is essential to understand the changes in emissions globally. In 2016 Tropospheric Monitoring Instrument (TROPOMI), will be launched on board ESA's Sentinel 5 Precursor satellite. TROPOMI will have a spatial resolution of 7x7 km2 in nadir; a more than 6 times improvement over OMI. The high spatial resolution serves two goals: (1) emissions sources can be detected with even better accuracy and (2) the number of cloud-free ground pixels will increase substantially. TROPOMI also adds additional spectral bands that allow for better cloud corrections, as well as the retrieval of carbon monoxide and methane. TROPOMI will be an important satellite mission for the Copernicus atmosphere service. TROPOMI will play a key role in the Air Quality Constellation, being the polar instruments that can link the 3 GEO UVN instruments, Sentinel 4, TEMPO and GEMS. Thus, TROPOMI can serve as a travelling standard that allows intercomparison of the calibration of the geostationary instruments. An overview of air quality applications, emission inversions and trend analyses will be presented, based on the 11 years of OMI data. An outlook will be presented on the potentials of TROPOMI, including its role in the Air Quality Constellation.
A reliable sewage quality abnormal event monitoring system.
Li, Tianling; Winnel, Melissa; Lin, Hao; Panther, Jared; Liu, Chang; O'Halloran, Roger; Wang, Kewen; An, Taicheng; Wong, Po Keung; Zhang, Shanqing; Zhao, Huijun
2017-09-15
With closing water loop through purified recycled water, wastewater becomes a part of source water, requiring reliable wastewater quality monitoring system (WQMS) to manage wastewater source and mitigate potential health risks. However, the development of reliable WQMS is fatally constrained by severe contamination and biofouling of sensors due to the hostile analytical environment of wastewaters, especially raw sewages, that challenges the limit of existing sensing technologies. In this work, we report a technological solution to enable the development of WQMS for real-time abnormal event detection with high reliability and practicality. A vectored high flow hydrodynamic self-cleaning approach and a dual-sensor self-diagnostic concept are adopted for WQMS to effectively encounter vital sensor failing issues caused by contamination and biofouling and ensure the integrity of sensing data. The performance of the WQMS has been evaluated over a 3-year trial period at different sewage catchment sites across three Australian states. It has demonstrated that the developed WQMS is capable of continuously operating in raw sewage for a prolonged period up to 24 months without maintenance and failure, signifying the high reliability and practicality. The demonstrated WQMS capability to reliably acquire real-time wastewater quality information leaps forward the development of effective wastewater source management system. The reported self-cleaning and self-diagnostic concepts should be applicable to other online water quality monitoring systems, opening a new way to encounter the common reliability and stability issues caused by sensor contamination and biofouling. Copyright © 2017 Elsevier Ltd. All rights reserved.
Blåhed, Ida-Maria; Königsson, Helena; Ericsson, Göran; Spong, Göran
2018-01-01
Monitoring of wild animal populations is challenging, yet reliable information about population processes is important for both management and conservation efforts. Access to molecular markers, such as SNPs, enables population monitoring through genotyping of various DNA sources. We have developed 96 high quality SNP markers for individual identification of moose (Alces alces), an economically and ecologically important top-herbivore in boreal regions. Reduced representation libraries constructed from 34 moose were high-throughput de novo sequenced, generating nearly 50 million read pairs. About 50 000 stacks of aligned reads containing one or more SNPs were discovered with the Stacks pipeline. Several quality criteria were applied on the candidate SNPs to find markers informative on the individual level and well representative for the population. An empirical validation by genotyping of sequenced individuals and additional moose, resulted in the selection of a final panel of 86 high quality autosomal SNPs. Additionally, five sex-specific SNPs and five SNPs for sympatric species diagnostics are included in the panel. The genotyping error rate was 0.002 for the total panel and probability of identities were low enough to separate individuals with high confidence. Moreover, the autosomal SNPs were highly informative also for population level analyses. The potential applications of this SNP panel are thus many including investigations of population size, sex ratios, relatedness, reproductive success and population structure. Ideally, SNP-based studies could improve today's population monitoring and increase our knowledge about moose population dynamics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Costa, Mafalda T., E-mail: mafaldatcosta@gmail.com; Carolino, Elisabete, E-mail: lizcarolino@gmail.com; Oliveira, Teresa A., E-mail: teresa.oliveira@uab.pt
In water supply systems with distribution networkthe most critical aspects of control and Monitoring of water quality, which generates crises system, are the effects of cross-contamination originated by the network typology. The classics of control of quality systems through the application of Shewhart charts are generally difficult to manage in real time due to the high number of charts that must be completed and evaluated. As an alternative to the traditional control systems with Shewhart charts, this study aimed to apply a simplified methodology of a monitoring plan quality parameters in a drinking water distribution, by applying Hotelling’s T{sup 2}more » charts and supplemented with Shewhart charts with Bonferroni limits system, whenever instabilities with processes were detected.« less
Low-Cost Oil Quality Sensor Based on Changes in Complex Permittivity
Pérez, Angel Torres; Hadfield, Mark
2011-01-01
Real time oil quality monitoring techniques help to protect important industry assets, minimize downtime and reduce maintenance costs. The measurement of a lubricant’s complex permittivity is an effective indicator of the oil degradation process and it can be useful in condition based maintenance (CBM) to select the most adequate oil replacement maintenance schedules. A discussion of the working principles of an oil quality sensor based on a marginal oscillator to monitor the losses of the dielectric at high frequencies (>1 MHz) is presented. An electronic design procedure is covered which results in a low cost, effective and ruggedized sensor implementation suitable for use in harsh environments. PMID:22346666
Acoustic Monitoring of Adhesive Bond Curing in Wood Laminates.
NASA Astrophysics Data System (ADS)
Biernacki, Jacek Marek
Challenges in manufacturing of wood products, such as glulam, include difficulty in controlling bonding variables and assessing bond quality. This dissertation investigates an ultrasonic method as a means of monitoring of curing and assessing bond quality in wood laminates. The effect of curing on ultrasonic transmission was studied using specimens of clear Douglas-fir, 100 x 200 x 600 mm, with the adhesive bond in the center of the specimen. Monitoring was performed simultaneously at normal and angular (5 ^circ nominal) incidence to the bond plane. Acoustic measurements were supplemented with destructive cure monitoring, standard bond strength measurement, monitoring of bulk viscosity curing, gel time measurement, and microscopic (SEM) examination. Angular incidence gave greater sensitivity to bond quality and curing status than did normal incidence. Analysis of wave propagation showed that displacement for transmission at a small angle (on the order of 5^circ ) was nearly parallel to the bond, which seems to explain greater sensitivity of angular incidence. Experimental results showed that this method was effective in detection of curing phases, such as spread, penetration, and hardening, defective bonds, and the effect of clamping pressure. An "unloading effect", measured as a relative transmission reduction after the clamping load was released, was sensitive to defective bonds, including uncured (kissing), underspread, and uneven spread bonds. Thick bonds (0.5 and 1.0 mm) caused the greatest increase in transmission, since waves at start of curing were highly attenuated. In angular transmission, thick-bond curing curves showed a characteristic inflection, which may be used to identify thick bonds and measure the curing rate. The results of this dissertation could be utilized to develop commercial systems in glulam manufacturing, which could evaluate: (a) phase of and completion of curing (b) bond quality (c) optimum clamping pressure. Similar systems could also be developed to monitor lumber and panel products curing at high temperature, such as LVL (laminated veneer lumber), OSB (oriented strandboard) and particleboard.
Study of Water Pollution Early Warning Framework Based on Internet of Things
NASA Astrophysics Data System (ADS)
Chengfang, H.; Xiao, X.; Dingtao, S.; Bo, C.; Xiongfei, W.
2016-06-01
In recent years, with the increasing world environmental pollution happening, sudden water pollution incident has become more and more frequently in China. It has posed a serious threat to water safety of the people living in the water source area. Conventional water pollution monitoring method is manual periodic testing, it maybe miss the best time to find that pollution incident. This paper proposes a water pollution warning framework to change this state. On the basis of the Internet of things, we uses automatic water quality monitoring technology to realize monitoring. We calculate the monitoring data with water pollution model to judge whether the water pollution incident is happen or not. Water pollution warning framework is divided into three layers: terminal as the sensing layer, it with the deployment of the automatic water quality pollution monitoring sensor. The middle layer is the transfer network layer, data information implementation is based on GPRS wireless network transmission. The upper one is the application layer. With these application systems, early warning information of water pollution will realize the high-speed transmission between grassroots units and superior units. The paper finally gives an example that applying this pollution warning framework to water quality monitoring of Beijing, China, it greatly improves the speed of the pollution warning responding of Beijing.
Aceituno, Anna M; Stanhope, Kaitlyn K; Rebolledo, Paulina A; Burke, Rachel M; Revollo, Rita; Iñiguez, Volga; Suchdev, Parminder S; Leon, Juan S
2017-11-28
Implementing rigorous epidemiologic studies in low-resource settings involves challenges in participant recruitment and follow-up (e.g., mobile populations, distrust), biological sample collection (e.g., cold-chain, laboratory equipment scarcity) and data collection (e.g., literacy, staff training, and infrastructure). This article describes the use of a monitoring and evaluation (M&E) framework to improve study efficiency and quality during participant engagement, and biological sample and data collection in a longitudinal cohort study of Bolivian infants. The study occurred between 2013 and 2015 in El Alto, Bolivia, a high-altitude, urban, low-resource community. The study's M&E framework included indicators for participant engagement (e.g., recruitment, retention, safety), biological sample (e.g., stool and blood), and data (e.g., anthropometry, questionnaires) collection and quality. Monitoring indicators were measured regularly throughout the study and used for course correction, communication, and staff retraining. Participant engagement indicators suggested that enrollment objectives were met (461 infants), but 15% loss-to-follow-up resulted in only 364 infants completing the study. Over the course of the study, there were four study-related adverse events (minor swelling and bruising related to a blood draw) and five severe adverse events (infant deaths) not related to study participation. Biological sample indicators demonstrated two blood samples collected from 95% (333 of 350 required) infants and stool collected for 61% of reported infant diarrhea episodes. Anthropometry data quality indicators were extremely high (median SDs for weight-for-length, length-for-age and weight-for-age z-scores 1.01, 0.98, and 1.03, respectively), likely due to extensive training, standardization, and monitoring efforts. Conducting human subjects research studies in low-resource settings often presents unique logistical difficulties, and collecting high-quality data is often a challenge. Investing in comprehensive M&E is important to improve participant recruitment, retention and safety, and sample and data quality. The M&E framework from this study can be applied to other longitudinal studies.
40 CFR 63.11221 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2013 CFR
2013-07-01
...-control periods, and required monitoring system quality assurance or quality control activities including... monitoring system quality assurance or quality control activities in calculations used to report emissions or... monitoring data I must obtain? 63.11221 Section 63.11221 Protection of Environment ENVIRONMENTAL PROTECTION...
40 CFR 60.2170 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2014 CFR
2014-07-01
... monitoring system quality assurance or quality control activities (including, as applicable, calibration... required monitoring system quality assurance or quality control activities including, as applicable... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Is there a minimum amount of monitoring...
40 CFR 63.11221 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2014 CFR
2014-07-01
...-control periods, and required monitoring system quality assurance or quality control activities including... monitoring system quality assurance or quality control activities in calculations used to report emissions or... monitoring data I must obtain? 63.11221 Section 63.11221 Protection of Environment ENVIRONMENTAL PROTECTION...
NASA Astrophysics Data System (ADS)
DeWinter, J. L.
2015-12-01
In 2010, the U.S. Environmental Protection Agency (EPA) revised the National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2) to include a primary health-based standard for hourly NO2. NO2 is a reactive gas that is emitted from motor vehicles, such as cars, trucks, and off-road equipment, as well as non-mobile sources, and is known to adversely affect human respiratory health. In conjunction with the NAAQS revision, EPA has mandated air quality monitoring next to selected major roadways throughout the United States that are in large urban areas where peak hourly NO2 concentrations are expected. Monitoring began in phases during 2012-2015 and included nitrogen dioxide (NO2), carbon monoxide (CO), and particulate matter smaller than 2.5 microns (PM2.5) at 40 monitoring sites nationwide. We conducted a national-scale review of near-road air pollutant concentrations, identified areas where high concentrations of NO2, PM2.5, and CO occurred, and evaluated how concentrations varied by factors such as location, distance to roadway, fleet mix characteristics, and traffic volume. We present the findings from our national near-road data assessment for the 2014 monitoring year.
Traditionally, the EPA has monitored aquatic ecosystems using statistically rigorous sample designs and intensive field efforts which provide high quality datasets. But by their nature they leave many aquatic systems unsampled, follow a top down approach, have a long lag between ...
Short-wavelength light beam in situ monitoring growth of InGaN/GaN green LEDs by MOCVD
2012-01-01
In this paper, five-period InGaN/GaN multiple quantum well green light-emitting diodes (LEDs) were grown by metal organic chemical vapor deposition with 405-nm light beam in situ monitoring system. Based on the signal of 405-nm in situ monitoring system, the related information of growth rate, indium composition and interfacial quality of each InGaN/GaN QW were obtained, and thus, the growth conditions and structural parameters were optimized to grow high-quality InGaN/GaN green LED structure. Finally, a green LED with a wavelength of 509 nm was fabricated under the optimal parameters, which was also proved by ex situ characterization such as high-resolution X-ray diffraction, photoluminescence, and electroluminescence. The results demonstrated that short-wavelength in situ monitoring system was a quick and non-destroyed tool to provide the growth information on InGaN/GaN, which would accelerate the research and development of GaN-based green LEDs. PMID:22650991
2004-08-01
land clearing action will be an irreversible commitment of resources. 4.3.2 Water Quality Construction project impacts to storm water quality can...nearby monitored outfalls for the MSGP. High turbidity, suspended solids, and decreased cross section due to deposition can violate storm water quality benchmarks...and result in a Notice of Violation for storm water quality permits. Beside erosive impacts, construction period activities can cause
Net-Based Training for Physicians
ERIC Educational Resources Information Center
Jokela, Paivi; Karlsudd, Peter
2009-01-01
In order to ensure and increase access to high-quality learning opportunities it is becoming more and more common to integrate e-learning into health-related environments. The rapid development of these new learning environments also requires continuous monitoring and evaluation, to guarantee the quality of the health-care education. In this…
Ayhan, Zehra; Eştürk, Okan
2009-06-01
Minimally processed ready-to-eat pomegranate arils have become popular due to their convenience, high value, unique sensory characteristics, and health benefits. The objective of this study was to monitor quality parameters and to extend the shelf life of ready-to-eat pomegranate arils packaged with modified atmospheres. Minimally processed pomegranate arils were packed in PP trays sealed with BOPP film under 4 atmospheres including low and super atmospheric oxygen. Packaged arils were stored at 5 degrees C for 18 d and monitored for internal atmosphere and quality attributes. Atmosphere equilibrium was reached for all MAP applications except for high oxygen. As a general trend, slight or no significant change was detected in chemical and physical attributes of pomegranate arils during cold storage. The aerobic mesophilic bacteria were in the range of 2.30 to 4.51 log CFU/g at the end of the storage, which did not affect the sensory quality. Overall, the pomegranate arils packed with air, nitrogen, and enriched oxygen kept quality attributes and were acceptable to sensory panelists on day 18; however, marketability period was limited to 15 d for the low oxygen atmosphere. PP trays sealed with BOPP film combined with either passive or active modified atmospheres and storage at 5 degrees C provided commercially acceptable arils for 18 d with high quality and convenience.
40 CFR 63.7535 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2014 CFR
2014-07-01
...-control periods, or required monitoring system quality assurance or control activities in data averages... required monitoring system quality assurance or quality control activities (including, as applicable... control activities. You must calculate monitoring results using all other monitoring data collected while...
40 CFR 63.7535 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2013 CFR
2013-07-01
...-control periods, or required monitoring system quality assurance or control activities in data averages... required monitoring system quality assurance or quality control activities (including, as applicable... control activities. You must calculate monitoring results using all other monitoring data collected while...
Karen Ferguson
2007-01-01
The measurement of water quality and stream health in wilderness areas is made difficult by the need to use non-motorized modes of travel. In Wyoming, data on streams in the high-altitude Cloud Peak Wilderness are scarce. The monitoring of stream health of the Tongue, Powder and Big Horn Rivers at lower altitudes can be made more meaningful by the collection of...
The OA System of College - - Design of the Teaching Quality Monitoring Subsystem
NASA Astrophysics Data System (ADS)
Wu, Hongjuan; Ying, Hong; Jiang, Youyi; Yan, Pei
According to the drawbacks of traditional teaching quality monitoring subsystems and based on the achievements of practical research in the teaching quality monitoring administration in College, this paper provides a design of overall structure of teaching quality monitoring subsystem, that is more suitable for colleges' management. This new system is endowed with the same features as .NET application programes: easy to extend, easy to maintain, flexible, convenient, and it let enterprises, students' parents and excellent graduates participate in teaching quality monitoring administration, have significant effect to ensure the quality of talent training in colleges.
40 CFR 60.2735 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2011 CFR
2011-07-01
....2770(o) of this part), and required monitoring system quality assurance or quality control activities... periods, and required monitoring system quality assurance or quality control activities including, as... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Is there a minimum amount of monitoring...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-14
... ambient air quality monitoring data for the period preceding the applicable attainment deadline. DATES... and certified monitoring data. A violation occurs when the ambient ozone air quality monitoring data... standard, generally based on air quality monitoring data from the 1987 through 1989 period (section 107(d...
Castell, Nuria; Dauge, Franck R; Schneider, Philipp; Vogt, Matthias; Lerner, Uri; Fishbain, Barak; Broday, David; Bartonova, Alena
2017-02-01
The emergence of low-cost, user-friendly and very compact air pollution platforms enable observations at high spatial resolution in near-real-time and provide new opportunities to simultaneously enhance existing monitoring systems, as well as engage citizens in active environmental monitoring. This provides a whole new set of capabilities in the assessment of human exposure to air pollution. However, the data generated by these platforms are often of questionable quality. We have conducted an exhaustive evaluation of 24 identical units of a commercial low-cost sensor platform against CEN (European Standardization Organization) reference analyzers, evaluating their measurement capability over time and a range of environmental conditions. Our results show that their performance varies spatially and temporally, as it depends on the atmospheric composition and the meteorological conditions. Our results show that the performance varies from unit to unit, which makes it necessary to examine the data quality of each node before its use. In general, guidance is lacking on how to test such sensor nodes and ensure adequate performance prior to marketing these platforms. We have implemented and tested diverse metrics in order to assess if the sensor can be employed for applications that require high accuracy (i.e., to meet the Data Quality Objectives defined in air quality legislation, epidemiological studies) or lower accuracy (i.e., to represent the pollution level on a coarse scale, for purposes such as awareness raising). Data quality is a pertinent concern, especially in citizen science applications, where citizens are collecting and interpreting the data. In general, while low-cost platforms present low accuracy for regulatory or health purposes they can provide relative and aggregated information about the observed air quality. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Abar, Caitlin C.; Turrisi, Robert J.; Mallett, Kimberly A.
2015-01-01
This study examined the extent to which profiles of perceived parenting are associated with trajectories of alcohol-related behaviors across the first year of college. Method Participants were surveyed five times from the summer prior to college to the fall of the second year. A total 285 college students were enrolled from the incoming classes of consecutive cohorts of students at a large, public university in the Northeastern U.S. At baseline, participants provided information on their parents’ alcohol-related behaviors (e.g., parental modeling of use; perceived approval of underage use) and parenting characteristics (e.g., parental monitoring; parent-child relationship quality). Students also reported on their personal alcohol-related behaviors at each time point. Results Latent profile analysis was used to identify four subgroups based on the set of parenting characteristics: High Quality (14%) – highest parent-teen relationship quality; High Monitoring (31%) – highest parental monitoring and knowledge; Low Involvement (30%) – poor relationship quality, little monitoring and communication; and Pro-Alcohol (21%) – highest parental modeling and approval. Students were then assigned to profiles, and their alcohol-related behaviors were examined longitudinally using latent growth curve modeling. In general, students in the Pro-Alcohol profile displayed the highest baseline levels of typical weekend drinking, heavy episodic drinking, and peak BAC, in addition to showing steeper increases in typical weekend drinking across the first year of college. Discussion Results support the notion that parental behaviors remain relevant across the first year of college. Differential alcohol-related behaviors across parenting profiles highlight the potential for tailored college intervention. PMID:23915366
High resolution remote sensing of densely urbanised regions: a case study of Hong Kong.
Nichol, Janet E; Wong, Man Sing
2009-01-01
Data on the urban environment such as climate or air quality is usually collected at a few point monitoring stations distributed over a city. However, the synoptic viewpoint of satellites where a whole city is visible on a single image permits the collection of spatially comprehensive data at city-wide scale. In spite of rapid developments in remote sensing systems, deficiencies in image resolution and algorithm development still exist for applications such as air quality monitoring and urban heat island analysis. This paper describes state-of-the-art techniques for enhancing and maximising the spatial detail available from satellite images, and demonstrates their applications to the densely urbanised environment of Hong Kong. An Emissivity Modulation technique for spatial enhancement of thermal satellite images permits modelling of urban microclimate in combination with other urban structural parameters at local scale. For air quality monitoring, a Minimum Reflectance Technique (MRT) has been developed for MODIS 500 m images. The techniques described can promote the routine utilization of remotely sensed images for environmental monitoring in cities of the 21(st) century.
Personal Air Pollution Exposure Monitoring using Low Cost Sensors in Chennai City
NASA Astrophysics Data System (ADS)
Reddy Yasa, Pavan; Shiva, Nagendra S. N.
2016-04-01
Air quality in many cities is deteriorating due to rapid urbanization and motorization. In the past, most of the health impacts studies in the urban areas have considered stationary air quality monitoring station data for health impact assessment. Since, there exist a spatial and temporal variation of air quality because of rapid change in land use pattern and complex interaction between emission sources and meteorological conditions, the human exposure assessment using stationary data may not provide realistic information. In such cases low cost sensors monitoring is viable in providing both spatial and temporal variations of air pollutant concentrations. In the present study an attempt has been made to use low cost sensor for monitoring the personal exposure to the two criteria pollutants CO and PM2.5 at 3 different locations of Chennai city. Maximum and minimum concentrations of CO and PM2.5 were found to be 5.4ppm, 0.8ppm and 534.8μg/m3, 1.9μg/m3 respectively. Results showed high concentrations near the intersection and low concentrations in the straight road.
On the use of the EMI for the health monitoring of bonded elements
NASA Astrophysics Data System (ADS)
Gulizzi, Vincenzo; Rizzo, Piervincenzo; Milazzo, Alberto
2014-03-01
The low weight, robustness and fatigue resistance of adhesive joints make them suitable for structural joints. A fully developed nondestructive evaluation technique however is needed to monitor and assess the quality of bonded joints. In the present paper the application of the electromechanical impedance (EMI) technique is proposed. In the EMI method a piezoelectric transducer (PZT) is attached to the structure of interest. The high sensitivity and low power consumption make the EMI method feasible for real time structural health monitoring. In this study we investigated the sensitivity of the electromechanical response of a PZT to the curing and the quality of the adhesive used for bonded joints. A PXI unit running under LabView and an auxiliary circuit were employed to measure the electric impedance of a PZT glued to an aluminum plate. The system aimed at monitoring the bond line between an aluminum strip and the plate. The conductive signature of the PZT was measured and analyzed during the curing. The experimental results show that the electromechanical impedance technique is sensitive to the curing time and variations are observed for adhesives of different quality.
High Resolution Remote Sensing of Densely Urbanised Regions: a Case Study of Hong Kong
Nichol, Janet E.; Wong, Man Sing
2009-01-01
Data on the urban environment such as climate or air quality is usually collected at a few point monitoring stations distributed over a city. However, the synoptic viewpoint of satellites where a whole city is visible on a single image permits the collection of spatially comprehensive data at city-wide scale. In spite of rapid developments in remote sensing systems, deficiencies in image resolution and algorithm development still exist for applications such as air quality monitoring and urban heat island analysis. This paper describes state-of-the-art techniques for enhancing and maximising the spatial detail available from satellite images, and demonstrates their applications to the densely urbanised environment of Hong Kong. An Emissivity Modulation technique for spatial enhancement of thermal satellite images permits modelling of urban microclimate in combination with other urban structural parameters at local scale. For air quality monitoring, a Minimum Reflectance Technique (MRT) has been developed for MODIS 500 m images. The techniques described can promote the routine utilization of remotely sensed images for environmental monitoring in cities of the 21st century. PMID:22408549
Satellite remote sensing for modeling and monitoring of water quality in the Great Lakes
NASA Astrophysics Data System (ADS)
Coffield, S. R.; Crosson, W. L.; Al-Hamdan, M. Z.; Barik, M. G.
2017-12-01
Consistent and accurate monitoring of the Great Lakes is critical for protecting the freshwater ecosystems, quantifying the impacts of climate change, understanding harmful algal blooms, and safeguarding public health for the millions who rely on the Lakes for drinking water. While ground-based monitoring is often hampered by limited sampling resolution, satellite data provide surface reflectance measurements at much more complete spatial and temporal scales. In this study, we implemented NASA data from the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua satellite to build robust water quality models. We developed and validated models for chlorophyll-a, nitrogen, phosphorus, and turbidity based on combinations of the six MODIS Ocean Color bands (412, 443, 488, 531, 547, and 667nm) for 2003-2016. Second, we applied these models to quantify trends in water quality through time and in relation to changing land cover, runoff, and climate for six selected coastal areas in Lakes Michigan and Erie. We found strongest models for chlorophyll-a in Lake Huron (R2 = 0.75), nitrogen in Lake Ontario (R2=0.66), phosphorus in Lake Erie (R2=0.60), and turbidity in Lake Erie (R2=0.86). These offer improvements over previous efforts to model chlorophyll-a while adding nitrogen, phosphorus, and turbidity. Mapped water quality parameters showed high spatial variability, with nitrogen concentrated largely in Superior and coastal Michigan and high turbidity, phosphorus, and chlorophyll near urban and agricultural areas of Erie. Temporal analysis also showed concurrence of high runoff or precipitation and nitrogen in Lake Michigan offshore of wetlands, suggesting that water quality in these areas is sensitive to changes in climate.
The Empower project - a new way of assessing and monitoring test comparability and stability.
De Grande, Linde A C; Goossens, Kenneth; Van Uytfanghe, Katleen; Stöckl, Dietmar; Thienpont, Linda M
2015-07-01
Manufacturers and laboratories might benefit from using a modern integrated tool for quality management/assurance. The tool should not be confounded by commutability issues and focus on the intrinsic analytical quality and comparability of assays as performed in routine laboratories. In addition, it should enable monitoring of long-term stability of performance, with the possibility to quasi "real-time" remedial action. Therefore, we developed the "Empower" project. The project comprises four pillars: (i) master comparisons with panels of frozen single-donation samples, (ii) monitoring of patient percentiles and (iii) internal quality control data, and (iv) conceptual and statistical education about analytical quality. In the pillars described here (i and ii), state-of-the-art as well as biologically derived specifications are used. In the 2014 master comparisons survey, 125 laboratories forming 8 peer groups participated. It showed not only good intrinsic analytical quality of assays but also assay biases/non-comparability. Although laboratory performance was mostly satisfactory, sometimes huge between-laboratory differences were observed. In patient percentile monitoring, currently, 100 laboratories participate with 182 devices. Particularly, laboratories with a high daily throughput and low patient population variation show a stable moving median in time with good between-instrument concordance. Shifts/drifts due to lot changes are sometimes revealed. There is evidence that outpatient medians mirror the calibration set-points shown in the master comparisons. The Empower project gives manufacturers and laboratories a realistic view on assay quality/comparability as well as stability of performance and/or the reasons for increased variation. Therefore, it is a modern tool for quality management/assurance toward improved patient care.
NASA Astrophysics Data System (ADS)
Hong, E.; Park, Y.; Muirhead, R.; Jeong, J.; Pachepsky, Y. A.
2017-12-01
Pathogenic microorganisms in recreational and irrigation waters remain the subject of concern. Water quality models are used to estimate microbial quality of water sources, to evaluate microbial contamination-related risks, to guide the microbial water quality monitoring, and to evaluate the effect of agricultural management on the microbial water quality. The Agricultural Policy/Environmental eXtender (APEX) is the watershed-scale water quality model that includes highly detailed representation of agricultural management. The APEX currently does not have microbial fate and transport simulation capabilities. The objective of this work was to develop the first APEX microbial fate and transport module that could use the APEX conceptual model of manure removal together with recently introduced conceptualizations of the in-stream microbial fate and transport. The module utilizes manure erosion rates found in the APEX. Bacteria survival in soil-manure mixing layer was simulated with the two-stage survival model. Individual survival patterns were simulated for each manure application date. Simulated in-stream microbial fate and transport processes included the reach-scale passive release of bacteria with resuspended bottom sediment during high flow events, the transport of bacteria from bottom sediment due to the hyporheic exchange during low flow periods, the deposition with settling sediment, and the two-stage survival. Default parameter values were available from recently published databases. The APEX model with the newly developed microbial fate and transport module was applied to simulate seven years of monitoring data for the Toenepi watershed in New Zealand. Based on calibration and testing results, the APEX with the microbe module reproduced well the monitored pattern of E. coli concentrations at the watershed outlet. The APEX with the microbial fate and transport module will be utilized for predicting microbial quality of water under various agricultural practices, evaluating monitoring protocols, and supporting the selection of management practices based on regulations that rely on fecal indicator bacteria concentrations.
Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants
NASA Technical Reports Server (NTRS)
Ramirez, W. Fred; Skliar, Mikhail; Narayan, Anand; Morgenthaler, George W.; Smith, Gerald J.
1996-01-01
Progress and results in the development of an integrated air quality modeling, monitoring, fault detection, and isolation system are presented. The focus was on development of distributed models of the air contaminants transport, the study of air quality monitoring techniques based on the model of transport process and on-line contaminant concentration measurements, and sensor placement. Different approaches to the modeling of spacecraft air contamination are discussed, and a three-dimensional distributed parameter air contaminant dispersion model applicable to both laminar and turbulent transport is proposed. A two-dimensional approximation of a full scale transport model is also proposed based on the spatial averaging of the three dimensional model over the least important space coordinate. A computer implementation of the transport model is considered and a detailed development of two- and three-dimensional models illustrated by contaminant transport simulation results is presented. The use of a well established Kalman filtering approach is suggested as a method for generating on-line contaminant concentration estimates based on both real time measurements and the model of contaminant transport process. It is shown that high computational requirements of the traditional Kalman filter can render difficult its real-time implementation for high-dimensional transport model and a novel implicit Kalman filtering algorithm is proposed which is shown to lead to an order of magnitude faster computer implementation in the case of air quality monitoring.
Wilcox, S.; Andreas, A.
2010-03-16
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Stoffel, T.; Andreas, A.
2010-04-26
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Wilcox, S.; Andreas, A.
2010-07-13
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Wilcox, S.; Andreas, A.
2012-11-03
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Solar Resource & Meteorological Assessment Project (SOLRMAP): Sun Spot Two; Swink, Colorado (Data)
Wilcox, S.; Andreas, A.
2010-11-10
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Wilcox, S.; Andreas, A.
2010-07-14
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Wilcox, S.; Andreas, A.
2009-07-22
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Wilcox, S.; Andreas, A.
2010-11-03
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
Techniques of monitoring blood glucose during pregnancy for women with pre-existing diabetes.
Moy, Foong Ming; Ray, Amita; Buckley, Brian S; West, Helen M
2017-06-11
Self-monitoring of blood glucose (SMBG) is recommended as a key component of the management plan for diabetes therapy during pregnancy. No existing systematic reviews consider the benefits/effectiveness of various techniques of blood glucose monitoring on maternal and infant outcomes among pregnant women with pre-existing diabetes. The effectiveness of the various monitoring techniques is unclear. To compare techniques of blood glucose monitoring and their impact on maternal and infant outcomes among pregnant women with pre-existing diabetes. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 November 2016), searched reference lists of retrieved studies and contacted trial authors. Randomised controlled trials (RCTs) and quasi-RCTs comparing techniques of blood glucose monitoring including SMBG, continuous glucose monitoring (CGM) or clinic monitoring among pregnant women with pre-existing diabetes mellitus (type 1 or type 2). Trials investigating timing and frequency of monitoring were also included. RCTs using a cluster-randomised design were eligible for inclusion but none were identified. Two review authors independently assessed study eligibility, extracted data and assessed the risk of bias of included studies. Data were checked for accuracy. The quality of the evidence was assessed using the GRADE approach. This review update includes at total of 10 trials (538) women (468 women with type 1 diabetes and 70 women with type 2 diabetes). The trials took place in Europe and the USA. Five of the 10 included studies were at moderate risk of bias, four studies were at low to moderate risk of bias, and one study was at high risk of bias. The trials are too small to show differences in important outcomes such as macrosomia, preterm birth, miscarriage or death of baby. Almost all the reported GRADE outcomes were assessed as being very low-quality evidence. This was due to design limitations in the studies, wide confidence intervals, small sample sizes, and few events. In addition, there was high heterogeneity for some outcomes.Various methods of glucose monitoring were compared in the trials. Neither pooled analyses nor individual trial analyses showed any clear advantages of one monitoring technique over another for primary and secondary outcomes. Many important outcomes were not reported.1. Self-monitoring versus standard care (two studies, 43 women): there was no clear difference for caesarean section (risk ratio (RR) 0.78, 95% confidence interval (CI) 0.40 to 1.49; one study, 28 women) or glycaemic control (both very low-quality), and not enough evidence to assess perinatal mortality and neonatal mortality and morbidity composite. Hypertensive disorders of pregnancy, large-for-gestational age, neurosensory disability, and preterm birth were not reported in either study.2. Self-monitoring versus hospitalisation (one study, 100 women): there was no clear difference for hypertensive disorders of pregnancy (pre-eclampsia and hypertension) (RR 4.26, 95% CI 0.52 to 35.16; very low-quality: RR 0.43, 95% CI 0.08 to 2.22; very low-quality). There was no clear difference in caesarean section or preterm birth less than 37 weeks' gestation (both very low quality), and the sample size was too small to assess perinatal mortality (very low-quality). Large-for-gestational age, mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.3. Pre-prandial versus post-prandial glucose monitoring (one study, 61 women): there was no clear difference between groups for caesarean section (RR 1.45, 95% CI 0.92 to 2.28; very low-quality), large-for-gestational age (RR 1.16, 95% CI 0.73 to 1.85; very low-quality) or glycaemic control (very low-quality). The results for hypertensive disorders of pregnancy: pre-eclampsia and perinatal mortality are not meaningful because these outcomes were too rare to show differences in a small sample (all very low-quality). The study did not report the outcomes mortality or morbidity composite, neurosensory disability or preterm birth.4. Automated telemedicine monitoring versus conventional system (three studies, 84 women): there was no clear difference for caesarean section (RR 0.96, 95% CI 0.62 to 1.48; one study, 32 women; very low-quality), and mortality or morbidity composite in the one study that reported these outcomes. There were no clear differences for glycaemic control (very low-quality). No studies reported hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), neurosensory disability or preterm birth.5.CGM versus intermittent monitoring (two studies, 225 women): there was no clear difference for pre-eclampsia (RR 1.37, 95% CI 0.52 to 3.59; low-quality), caesarean section (average RR 1.00, 95% CI 0.65 to 1.54; I² = 62%; very low-quality) and large-for-gestational age (average RR 0.89, 95% CI 0.41 to 1.92; I² = 82%; very low-quality). Glycaemic control indicated by mean maternal HbA1c was lower for women in the continuous monitoring group (mean difference (MD) -0.60 %, 95% CI -0.91 to -0.29; one study, 71 women; moderate-quality). There was not enough evidence to assess perinatal mortality and there were no clear differences for preterm birth less than 37 weeks' gestation (low-quality). Mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.6. Constant CGM versus intermittent CGM (one study, 25 women): there was no clear difference between groups for caesarean section (RR 0.77, 95% CI 0.33 to 1.79; very low-quality), glycaemic control (mean blood glucose in the 3rd trimester) (MD -0.14 mmol/L, 95% CI -2.00 to 1.72; very low-quality) or preterm birth less than 37 weeks' gestation (RR 1.08, 95% CI 0.08 to 15.46; very low-quality). Other primary (hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), mortality or morbidity composite, and neurosensory disability) or GRADE outcomes (preterm birth less than 34 weeks' gestation) were not reported. This review found no evidence that any glucose monitoring technique is superior to any other technique among pregnant women with pre-existing type 1 or type 2 diabetes. The evidence base for the effectiveness of monitoring techniques is weak and additional evidence from large well-designed randomised trials is required to inform choices of glucose monitoring techniques.
Air Quality Monitoring: Risk-Based Choices
NASA Technical Reports Server (NTRS)
James, John T.
2009-01-01
Air monitoring is secondary to rigid control of risks to air quality. Air quality monitoring requires us to target the credible residual risks. Constraints on monitoring devices are severe. Must transition from archival to real-time, on-board monitoring. Must provide data to crew in a way that they can interpret findings. Dust management and monitoring may be a major concern for exploration class missions.
Paule, M A; Memon, S A; Lee, B-Y; Umer, S R; Lee, C-H
2014-01-01
Stormwater runoff quality is sensitive to land use and land cover (LULC) change. It is difficult to understand their relationship in predicting the pollution potential and developing watershed management practices to eliminate or reduce the pollution risk. In this study, the relationship between LULC change and stormwater runoff quality in two separate monitoring sites comprising a construction area (Site 1) and mixed land use (Site 2) was analyzed using geographic information system (GIS), event mean concentration (EMC), and correlation analysis. It was detected that bare land area increased, while other land use areas such as agriculture, commercial, forest, grassland, parking lot, residential, and road reduced. Based on the analyses performed, high maximum range and average EMCs were found in Site 2 for most of the water pollutants. Also, urban areas and increased conversion of LULC into bare land corresponded to degradation of stormwater quality. Correlation analysis between LULC and stormwater quality showed the influence of different factors such as farming practices, geographical location, and amount of precipitation, vegetation loss, and anthropogenic activities in monitoring sites. This research found that GIS application was an efficient tool for monthly monitoring, validation and statistical analysis of LULC change in the study area.
Bennett, Trudy J.; Graham, Jennifer L.; Foster, Guy M.; Stone, Mandy L.; Juracek, Kyle E.; Rasmussen, Teresa J.; Putnam, James E.
2014-01-01
A quality-assurance plan for use in conducting continuous water-quality monitoring activities has been developed for the Kansas Water Science Center in accordance with guidelines set forth by the U.S. Geological Survey. This quality-assurance plan documents the standards, policies, and procedures used by the U.S. Geological Survey in Kansas for activities related to the collection, processing, storage, analysis, and release of continuous water-quality monitoring data. The policies and procedures that are documented in this quality-assurance plan for continuous water-quality monitoring activities complement quality-assurance plans for surface-water and groundwater activities in Kansas.
NASA Astrophysics Data System (ADS)
van Geer, Frans C.; Kronvang, Brian; Broers, Hans Peter
2016-09-01
Four sessions on "Monitoring Strategies: temporal trends in groundwater and surface water quality and quantity" at the EGU conferences in 2012, 2013, 2014, and 2015 and a special issue of HESS form the background for this overview of the current state of high-resolution monitoring of nutrients. The overview includes a summary of technologies applied in high-frequency monitoring of nutrients in the special issue. Moreover, we present a new assessment of the objectives behind high-frequency monitoring as classified into three main groups: (i) improved understanding of the underlying hydrological, chemical, and biological processes (PU); (ii) quantification of true nutrient concentrations and loads (Q); and (iii) operational management, including evaluation of the effects of mitigation measures (M). The contributions in the special issue focus on the implementation of high-frequency monitoring within the broader context of policy making and management of water in Europe for support of EU directives such as the Water Framework Directive, the Groundwater Directive, and the Nitrates Directive. The overview presented enabled us to highlight the typical objectives encountered in the application of high-frequency monitoring and to reflect on future developments and research needs in this growing field of expertise.
Arshad, Nasima; Imran, Saiqa
2017-01-01
High levels of arsenic contamination in drinking water of two villages, Badarpur and Ibrahimabad of district Kasur, central Punjab, Pakistan is reported first time in present studies. Groundwater quality situation was found to be impaired when samples of different rural areas of district Kasur were monitored according to Pakistan Standards and Quality Control Authority (PSQCA) for all significant water quality constituents and analyzed for trace elements, physico-chemical, and microbiological parameters. Out of 35water sources, 97 % were found unsafe and only 3 % of the sources were within safe limits. High concentrations of arsenic, fluoride, and bacteria were found in 91, 74, and 77 % sources of drinking water, respectively. Very high concentrations of arsenic ranging 58-3800 μg/L were found in the water samples obtained from Badarpur and Ibrahimabad. A decrease in water contamination was observed with increase in source depth. The health issues like arsenicosis and skeletal/dental flourosis were observed in the residents of the monitored areas. Drinking water quality conditions of some rural areas of northen and southern districts of Punjab was also analyzed and compared with Kasur district. High levels of nitrates were found in the samples of Islamabad and Rawalpindi, while high levels of arsenic, iron, fluoride, and TDS were found in Bahawalpur district. Graphical abstract ᅟ.
NASA Astrophysics Data System (ADS)
Simuel, Gloria J.
Heart Failure continues to be a major public health problem associated with high mortality and morbidity. Heart Failure is the leading cause of hospitalization for persons older than 65 years, has a poor prognosis and is associated with poor quality of life. More than 5.3 million American adults are living with heart failure. Despite maximum medical therapy and frequent hospitalizations to stabilize their condition, one in five heart failure patients die within the first year of diagnosis. Several disease-management programs have been proposed and tested to improve the quality of heart failure care. Studies have shown that hospital admissions and emergency room visits decrease with increased nursing interventions in the home and community setting. An alternative strategy for promoting self-management of heart failure is the use of electronic home monitoring. The purpose of this study was to examine what effects heart failure has on patient's quality of life that had been monitoring on an electronic home monitor longer than 2 months. Twenty-one questionnaires were given to patients utilizing an electronic home monitor by their home health agency nurse. Eleven patients completed the questionnaire. The findings showed that there is some deterioration in quality of life with more association with the physical aspects of life than with the emotional aspects of life, which probably was due to the small sample size. There was no significant difference in readmission rates in patients utilizing an electronic home monitor. Further research is needed with a larger population of patients with chronic heart failure and other chronic diseases which may provide more data, and address issues such as patient compliance with self-care, impact of heart failure on patient's quality of life, functional capacity, and heart failure patient's utilization of the emergency rooms and hospital. Telemonitoring holds promise for improving the self-care abilities of persons with HF.
Melcher, Anthony A; Horsburgh, Jeffery S
2017-06-01
Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.
Quality aspects of digital radiography in general dental practice.
Hellén-Halme, Kristina
2007-01-01
The number of dentists who have converted from conventional film radiography to digital radiography continues to grow. A digital system has numerous advantages, but there are also many new aspects to consider. The overall aim of this thesis was to study how digital radiography was used in general dental practices. The specific aims were to study how different factors affected image quality. To determine whether there were any differences in image quality between conventional film radiographs and digital radiographs, 4863 images (540 cases) were evaluated. The cases had been sent to the Swedish Dental Insurance Office for prior treatment approval. The image quality of digital radiographs was found to be significantly lower than that of film radiographs. This result led to a questionnaire study of dentists experienced in digital radiography. In 2003, a questionnaire was sent to the 139 general practice dentists who worked with digital radiography in Skine, Sweden; the response rate was 94%. Many general practice dentists had experienced several problems (65%), and less than half of the digital systems (40%) underwent some kind of quality control. One of the weaker links in the technical chain of digital radiography appeared to be the monitor. A field study to 19 dentists at their clinics found that the brightness and contrast settings of the monitors had to be adjusted to obtain the subjectively best image quality. The ambient light in the evaluation room was also found to affect the diagnostic outcome of low-contrast patterns in radiographs. To evaluate the effects of ambient light and technical adjustments of the monitor, a study using standardised set-ups was designed. Seven observers evaluated radiographs of 100 extracted human teeth for approximal caries under five different combinations of brightness and contrast settings on two different occasions with high and low ambient light levels in the evaluation room. The ability to diagnose carious lesions was found to be significantly better in a room with lower ambient light and on a monitor with well-adjusted brightness and contrast values than in a room with bright light and on an unadjusted monitor. In conclusion, many problems with dental digital radiography were identified. Knowledge of digital techniques and how to optimise each link in the system to maintain high radiographic quality at all times must be improved.
Dou, Ming; Zhang, Yan; Li, Guiqiu
2016-09-01
Based on the monitoring data of 78 monitoring stations from 2003 to 2012, five key water quality indexes (biochemical oxygen demand: BOD5, permanganate index: CODMn, dissolved oxygen: DO, ammonium nitrogen: NH3-N, and total phosphorus: TP) were selected to analyze their temporal and spatial characteristics in the highly disturbed Huaihe River Basin via Mann-Kendall trend analysis and boxplot analysis. The temporal and spatial variations of water pollutant concentrations in the Huaihe River Basin were investigated and analyzed to provide a scientific basis for water pollution control, water environment protection, and ecological restoration. The results indicated that the Yinghe River, Quanhe River, Honghe River, Guohe River, and Baohe River were the most seriously polluted rivers, followed by Hongze Lake, Luoma Lake, Yishuhe River, and Nansi Lake. BOD5, CODMn, and NH3-N were the major pollution indexes, for which the monitoring stations reported that more than 40 % of the water quality concentrations exceeded the class IV level. There were 21, 50, 36, and 21 monitoring stations that recorded significantly decreasing trends for BOD5, CODMn, NH3-N, and TP, respectively, and 39 monitoring stations showed a significantly increasing trend for DO. Moreover, the water quality concentrations had a certain concentricity and volatility according to boxplot analysis for the 20 monitoring stations. The majority of monitoring stations recorded a large fluctuation for the monitoring indexes in 2003 and 2004, which indicated that the water quality concentrations were unstable. According to the seasonal variations of the water quality concentrations in the mainstream of Huaihe River, the monthly variation trends of the BOD5, CODMn, DO, NH3-N, and TP concentrations were basically consistent among the seven monitoring stations. The BOD5, CODMn, NH3-N, and TP concentrations were affected by the change of the stream discharge; changes in DO and NH3-N concentrations were influenced by the regional environmental temperature, and the DO and NH3-N concentrations decreased when the water temperature increased.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Létourneau, Daniel, E-mail: daniel.letourneau@rmp.uh.on.ca; McNiven, Andrea; Keller, Harald
2014-12-15
Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods:more » The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.« less
40 CFR 130.4 - Water quality monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...; developing and reviewing water quality standards, total maximum daily loads, wasteload allocations and load... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Water quality monitoring. 130.4...
40 CFR 130.4 - Water quality monitoring.
Code of Federal Regulations, 2011 CFR
2011-07-01
... QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...; developing and reviewing water quality standards, total maximum daily loads, wasteload allocations and load... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Water quality monitoring. 130.4...
ATEE Interactive Co-ordination and Educational Monitoring of Socrates Comenius Action 3 Projects.
ERIC Educational Resources Information Center
Libotton, Arno; Van Braak, Johan; Garofalo, Mara
2002-01-01
Asserts that although the Comenius Action 3 courses were well-accepted and high quality, there is a need for a structure for easily monitoring and evaluating these projects. This article presents a pilot project designed with this purpose, which may be useful in implementing a system of coordination and communication among the different projects…
Tool path strategy and cutting process monitoring in intelligent machining
NASA Astrophysics Data System (ADS)
Chen, Ming; Wang, Chengdong; An, Qinglong; Ming, Weiwei
2018-06-01
Intelligent machining is a current focus in advanced manufacturing technology, and is characterized by high accuracy and efficiency. A central technology of intelligent machining—the cutting process online monitoring and optimization—is urgently needed for mass production. In this research, the cutting process online monitoring and optimization in jet engine impeller machining, cranio-maxillofacial surgery, and hydraulic servo valve deburring are introduced as examples of intelligent machining. Results show that intelligent tool path optimization and cutting process online monitoring are efficient techniques for improving the efficiency, quality, and reliability of machining.
Capela, R; Raimundo, J; Santos, M M; Caetano, M; Micaelo, C; Vale, C; Guimarães, L; Reis-Henriques, M A
2016-01-01
The Water Framework Directive (WFD) provides an important legislative opportunity to promote and implement an integrated approach for the protection of inland surface waters, transitional waters, coastal waters and groundwaters. The transitional waters constitute a central piece as they are usually under high environmental pressure and by their inherent characteristics present monitoring challenges. Integrating water quality monitoring with biological monitoring can increase the cost-effectiveness of monitoring efforts. One way of doing this is with biomarkers, which effectively integrate physical-chemical status and biological quality elements, dealing holistically with adverse consequences on the health of water bodies. The new Marine Strategy Framework Directive (MSFD) already incorporates the biomarker approach. Given the recent activities of OSPAR and HELCOM to harmonize existing monitoring guidelines between MSFD and WFD the use of similar methodologies should be fostered. To illustrate the potential of the biomarker approach, juveniles of flounder (Platichthys flesus) were used to evaluate the quality of the Minho river-estuary water bodies. The use of juveniles instead of adults eliminates several confounding factors such changes on the biological responses associated with reproduction. Here, a panel of well-established biomarkers, EROD, AChE, SOD, CAT, GST, LPO, ENA and FACs (1-Hydroxyrene) were selected and measured along with a gradient of different physical conditions, and integrated with trace elements characterization on both biota and sediments. In general, a clear profile along the water bodies was found, with low seasonal and spatial variation, consistent with a low impacted area. Overall, the results support the use of both the battery of biomarkers and the use of juvenile flounders in the monitoring of the water quality status within the WFD. Copyright © 2015 Elsevier B.V. All rights reserved.
High resolution pollutant measurements in complex urban ...
Measuring air pollution in real-time using an instrumented vehicle platform has been an emerging strategy to resolve air pollution trends at a very fine spatial scale (10s of meters). Achieving second-by-second data representative of urban air quality trends requires advanced instrumentation, such as a quantum cascade laser utilized to resolve carbon monoxide and real-time optical detection of black carbon. An equally challenging area of development is processing and visualization of complex geospatial air monitoring data to decipher key trends of interest. EPA’s Office of Research and Development staff have applied air monitoring to evaluate community air quality in a variety of environments, including assessing air quality surrounding rail yards, evaluating noise wall or tree stand effects on roadside and on-road air quality, and surveying of traffic-related exposure zones for comparison with land-use regression estimates. ORD has ongoing efforts to improve mobile monitoring data collection and interpretation, including instrumentation testing, evaluating the effect of post-processing algorithms on derived trends, and developing a web-based tool called Real-Time Geospatial Data Viewer (RETIGO) allowing for a simple plug-and-play of mobile monitoring data. Example findings from mobile data sets include an estimated 50% in roadside ultrafine particle levels when immediately downwind of a noise barrier, increases in neighborhood-wide black carbon levels (3
Cost-effective handling of digital medical images in the telemedicine environment.
Choong, Miew Keen; Logeswaran, Rajasvaran; Bister, Michel
2007-09-01
This paper concentrates on strategies for less costly handling of medical images. Aspects of digitization using conventional digital cameras, lossy compression with good diagnostic quality, and visualization through less costly monitors are discussed. For digitization of film-based media, subjective evaluation of the suitability of digital cameras as an alternative to the digitizer was undertaken. To save on storage, bandwidth and transmission time, the acceptable degree of compression with diagnostically no loss of important data was studied through randomized double-blind tests of the subjective image quality when compression noise was kept lower than the inherent noise. A diagnostic experiment was undertaken to evaluate normal low cost computer monitors as viable viewing displays for clinicians. The results show that conventional digital camera images of X-ray images were diagnostically similar to the expensive digitizer. Lossy compression, when used moderately with the imaging noise to compression noise ratio (ICR) greater than four, can bring about image improvement with better diagnostic quality than the original image. Statistical analysis shows that there is no diagnostic difference between expensive high quality monitors and conventional computer monitors. The results presented show good potential in implementing the proposed strategies to promote widespread cost-effective telemedicine and digital medical environments. 2006 Elsevier Ireland Ltd
Early warning of changing drinking water quality by trend analysis.
Tomperi, Jani; Juuso, Esko; Leiviskä, Kauko
2016-06-01
Monitoring and control of water treatment plants play an essential role in ensuring high quality drinking water and avoiding health-related problems or economic losses. The most common quality variables, which can be used also for assessing the efficiency of the water treatment process, are turbidity and residual levels of coagulation and disinfection chemicals. In the present study, the trend indices are developed from scaled measurements to detect warning signs of changes in the quality variables of drinking water and some operating condition variables that strongly affect water quality. The scaling is based on monotonically increasing nonlinear functions, which are generated with generalized norms and moments. Triangular episodes are classified with the trend index and its derivative. Deviation indices are used to assess the severity of situations. The study shows the potential of the described trend analysis as a predictive monitoring tool, as it provides an advantage over the traditional manual inspection of variables by detecting changes in water quality and giving early warnings.
Dutta, Rishiraj
2013-08-15
This study tries to quantify the effects of green leaf tea parameters that influence tea quality in Northeast India. The study is to identify the different parameters that have a significant influence on tea quality through the use of remote sensing. It investigates the methods for estimating tea quality based on remotely sensed Normalized Difference Vegetation Index (NDVI) data. Attention focused on high yielding TV clones (TV1, TV18, TV22, TV23, TV25 and TV26). NDVI was obtained from ASTER images. Statistical analysis shows that NDVI has a strong significant effect on the caffeine content followed by epicatechin (EC), epigallocatechin (EGC) and to some extent in other chemical parameters. Relationships therefore exist between quality parameters and remote sensing in particular for the TV clones. This leads to the conclusion that NDVI has a large potential to be used for monitoring tea quality of individual cultivars in the future. Copyright © 2013 Elsevier Ltd. All rights reserved.
Different methods and settings for glucose monitoring for gestational diabetes during pregnancy.
Raman, Puvaneswary; Shepherd, Emily; Dowswell, Therese; Middleton, Philippa; Crowther, Caroline A
2017-10-29
Incidence of gestational diabetes mellitus (GDM) is increasing worldwide. Blood glucose monitoring plays a crucial part in maintaining glycaemic control in women with GDM and is generally recommended by healthcare professionals. There are several different methods for monitoring blood glucose which can be carried out in different settings (e.g. at home versus in hospital). The objective of this review is to compare the effects of different methods and settings for glucose monitoring for women with GDM on maternal and fetal, neonatal, child and adult outcomes, and use and costs of health care. We searched the Cochrane Pregnancy and Childbirth Group Trials Register (30 September 2016) and reference lists of retrieved studies. Randomised controlled trials (RCTs) or quasi-randomised controlled trials (qRCTs) comparing different methods (such as timings and frequencies) or settings, or both, for blood glucose monitoring for women with GDM. Two authors independently assessed study eligibility, risk of bias, and extracted data. Data were checked for accuracy.We assessed the quality of the evidence for the main comparisons using GRADE, for:- primary outcomes for mothers: that is, hypertensive disorders of pregnancy; caesarean section; type 2 diabetes; and- primary outcomes for children: that is, large-for-gestational age; perinatal mortality; death or serious morbidity composite; childhood/adulthood neurosensory disability;- secondary outcomes for mothers: that is, induction of labour; perineal trauma; postnatal depression; postnatal weight retention or return to pre-pregnancy weight; and- secondary outcomes for children: that is, neonatal hypoglycaemia; childhood/adulthood adiposity; childhood/adulthood type 2 diabetes. We included 11 RCTs (10 RCTs; one qRCT) that randomised 1272 women with GDM in upper-middle or high-income countries; we considered these to be at a moderate to high risk of bias. We assessed the RCTs under five comparisons. For outcomes assessed using GRADE, we downgraded for study design limitations, imprecision and inconsistency. Three trials received some support from commercial partners who provided glucose meters or financial support, or both. Main comparisons Telemedicine versus standard care for glucose monitoring (five RCTs): we observed no clear differences between the telemedicine and standard care groups for the mother, for:- pre-eclampsia or pregnancy-induced hypertension (risk ratio (RR) 1.49, 95% confidence interval (CI) 0.69 to 3.20; 275 participants; four RCTs; very low quality evidence);- caesarean section (average RR 1.05, 95% CI 0.72 to 1.53; 478 participants; 5 RCTs; very low quality evidence); and- induction of labour (RR 1.06, 95% CI 0.63 to 1.77; 47 participants; 1 RCT; very low quality evidence);or for the child, for:- large-for-gestational age (RR 1.41, 95% CI 0.76 to 2.64; 228 participants; 3 RCTs; very low quality evidence);- death or serious morbidity composite (RR 1.06, 95% CI 0.68 to 1.66; 57 participants; 1 RCT; very low quality evidence); and- neonatal hypoglycaemia (RR 1.14, 95% CI 0.48 to 2.72; 198 participants; 3 RCTs; very low quality evidence).There were no perinatal deaths in two RCTs (131 participants; very low quality evidence). Self-monitoring versus periodic glucose monitoring (two RCTs): we observed no clear differences between the self-monitoring and periodic glucose monitoring groups for the mother, for:- pre-eclampsia (RR 0.17, 95% CI 0.01 to 3.49; 58 participants; 1 RCT; very low quality evidence); and- caesarean section (average RR 1.18, 95% CI 0.61 to 2.27; 400 participants; 2 RCTs; low quality evidence);or for the child, for:- perinatal mortality (RR 1.54, 95% CI 0.21 to 11.24; 400 participants; 2 RCTs; very low quality evidence);- large-for-gestational age (RR 0.82, 95% CI 0.50 to 1.37; 400 participants; 2 RCTs; low quality evidence); and- neonatal hypoglycaemia (RR 0.64, 95% CI 0.39 to 1.06; 391 participants; 2 RCTs; low quality evidence). Continuous glucose monitoring system (CGMS) versus self-monitoring of glucose (two RCTs): we observed no clear differences between the CGMS and self-monitoring groups for the mother, for:- caesarean section (RR 0.91, 95% CI 0.68 to 1.20; 179 participants; 2 RCTs; very low quality evidence);or for the child, for:- large-for-gestational age (RR 0.67, 95% CI 0.43 to 1.05; 106 participants; 1 RCT; very low quality evidence) and- neonatal hypoglycaemia (RR 0.79, 95% CI 0.35 to 1.78; 179 participants; 2 RCTs; very low quality evidence).There were no perinatal deaths in the two RCTs (179 participants; very low quality evidence). Other comparisons Modem versus telephone transmission for glucose monitoring (one RCT): none of the review's primary outcomes were reported in this trial Postprandial versus preprandial glucose monitoring (one RCT): we observed no clear differences between the postprandial and preprandial glucose monitoring groups for the mother, for:- pre-eclampsia (RR 1.00, 95% CI 0.15 to 6.68; 66 participants; 1 RCT);- caesarean section (RR 0.62, 95% CI 0.29 to 1.29; 66 participants; 1 RCT); and- perineal trauma (RR 0.38, 95% CI 0.11 to 1.29; 66 participants; 1 RCT);or for the child, for:- neonatal hypoglycaemia (RR 0.14, 95% CI 0.02 to 1.10; 66 participants; 1 RCT).There were fewer large-for-gestational-age infants born to mothers in the postprandial compared with the preprandial glucose monitoring group (RR 0.29, 95% CI 0.11 to 0.78; 66 participants; 1 RCT). Evidence from 11 RCTs assessing different methods or settings for glucose monitoring for GDM suggests no clear differences for the primary outcomes or other secondary outcomes assessed in this review.However, current evidence is limited by the small number of RCTs for the comparisons assessed, small sample sizes, and the variable methodological quality of the RCTs. More evidence is needed to assess the effects of different methods and settings for glucose monitoring for GDM on outcomes for mothers and their children, including use and costs of health care. Future RCTs may consider collecting and reporting on the standard outcomes suggested in this review.
Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.
Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke
2015-12-01
Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.
Hydrochemical processes in lowland rivers: insights from in situ, high-resolution monitoring
NASA Astrophysics Data System (ADS)
Wade, A. J.; Palmer-Felgate, E. J.; Halliday, S. J.; Skeffington, R. A.; Loewenthal, M.; Jarvie, H. P.; Bowes, M. J.; Greenway, G. M.; Haswell, S. J.; Bell, I. M.; Joly, E.; Fallatah, A.; Neal, C.; Williams, R. J.; Gozzard, E.; Newman, J. R.
2012-11-01
This paper introduces new insights into the hydrochemical functioning of lowland river systems using field-based spectrophotometric and electrode technologies. The streamwater concentrations of nitrogen species and phosphorus fractions were measured at hourly intervals on a continuous basis at two contrasting sites on tributaries of the River Thames - one draining a rural catchment, the River Enborne, and one draining a more urban system, The Cut. The measurements complement those from an existing network of multi-parameter water quality sondes maintained across the Thames catchment and weekly monitoring based on grab samples. The results of the sub-daily monitoring show that streamwater phosphorus concentrations display highly complex dynamics under storm conditions dependent on the antecedent catchment wetness, and that diurnal phosphorus and nitrogen cycles occur under low flow conditions. The diurnal patterns highlight the dominance of sewage inputs in controlling the streamwater phosphorus and nitrogen concentrations at low flows, even at a distance of 7 km from the nearest sewage treatment works in the rural River Enborne. The time of sample collection is important when judging water quality against ecological thresholds or standards. An exhaustion of the supply of phosphorus from diffuse and multiple septic tank sources during storm events was evident and load estimation was not improved by sub-daily monitoring beyond that achieved by daily sampling because of the eventual reduction in the phosphorus mass entering the stream during events. The results highlight the utility of sub-daily water quality measurements and the discussion considers the practicalities and challenges of in situ, sub-daily monitoring.
NASA Astrophysics Data System (ADS)
Collins, A.; Lloyd, C.; Freer, J. E.; Johnes, P.; Stirling, M.
2012-12-01
One of the biggest challenges in catchment water quality management is tackling the problem of reducing water pollution from agriculture whilst ensuring food security nationally. Improvements to catchment management plans are needed if we are to enhance biodiversity and maintain good ecological status in freshwater ecosystems, while producing enough food to support a growing global population. In order to plan for a more sustainable and secure future, research needs to quantify the uncertainties and understand the complexities in the source-mobilisation-delivery-impact continuum of pollution and nutrients at all scales. In the UK the Demonstration Test Catchment (DTC) project has been set up to improve water quality specifically from diffuse pollution from agriculture by enhanced high resolution monitoring and targeted mitigation experiments. The DTC project aims to detect shifts in the baseline trend of the most ecologically-significant pollutants resulting from targeted on-farm measures at field to farm scales and assessing their effects on ecosystem function. The DTC programme involves three catchments across the UK that are indicative of three different typologies and land uses. This paper will focus on the Hampshire Avon DTC, where a total of 12 parameters are monitored by bank-side stations at two sampling sites, including flow, turbidity, phosphate and nitrate concentrations at 30 min resolution. This monitoring is supported by daily resolution sampling at 5 other sites and storm sampling at all locations. Part of the DTC project aims to understand how observations of water quality within river systems at different temporal resolutions and types of monitoring strategies enable us to understand and detect changes over and above the natural variability. Baseline monitoring is currently underway and early results show that high-resolution data is essential at this sub-catchment scale to understand important process dynamics. This is critical if we are to design cost efficient and effective management strategies. The high-resolution dataset means that there are new opportunities to explore the associated uncertainties in monitoring water quality and assessing ecological status and how that relates to current monitoring networks. For example, concurrent grab samples at the high-resolution sampling stations allow the assessment of the uncertainties which would be generated through coarser sampling strategies. This is just the beginning of the project, however, as the project progresses, the high resolution dataset will provide higher statistical power compared with previous data collection schemes and allow the employment of more complex methods such as signal decomposition e.g. wavelet analysis, which can allow us to start to decipher the complex interactions occurring at sub-catchment scale which may not be immediately detectable in bulk signals. In this paper we outline our methodological approach, present some of the initial findings of this research and how we can quantify changes to nutrient loads whilst taking account the main uncertainties and the inherent natural variability.
In-Situ Cure Monitoring of the Immidization Reaction of PMR-15
NASA Technical Reports Server (NTRS)
Cossins, Sheryl; Kellar, Jon J.; Winter, Robb M.
1997-01-01
Glass fiber reinforced polymer composites are becoming widely used in industry. With this increase in production, an in-situ method of quality control for the curing of the polymer is desirable. This would allow for the production of high-quality parts having more uniform properties.' Recently, in-situ fiber optic monitoring of polymer curing has primarily focused on epoxy resins and has been performed by Raman or fluorescence methods. In addition, some infrared (IR) investigations have been performed using transmission or ATR cells. An alternate IR approach involves using optical fibers as a sensor by utilizing evanescent wave spectroscopy.
NASA Astrophysics Data System (ADS)
Lobuglio, Joseph N.; Characklis, Gregory W.; Serre, Marc L.
2007-03-01
Sparse monitoring data and error inherent in water quality models make the identification of waters not meeting regulatory standards uncertain. Additional monitoring can be implemented to reduce this uncertainty, but it is often expensive. These costs are currently a major concern, since developing total maximum daily loads, as mandated by the Clean Water Act, will require assessing tens of thousands of water bodies across the United States. This work uses the Bayesian maximum entropy (BME) method of modern geostatistics to integrate water quality monitoring data together with model predictions to provide improved estimates of water quality in a cost-effective manner. This information includes estimates of uncertainty and can be used to aid probabilistic-based decisions concerning the status of a water (i.e., impaired or not impaired) and the level of monitoring needed to characterize the water for regulatory purposes. This approach is applied to the Catawba River reservoir system in western North Carolina as a means of estimating seasonal chlorophyll a concentration. Mean concentration and confidence intervals for chlorophyll a are estimated for 66 reservoir segments over an 11-year period (726 values) based on 219 measured seasonal averages and 54 model predictions. Although the model predictions had a high degree of uncertainty, integration of modeling results via BME methods reduced the uncertainty associated with chlorophyll estimates compared with estimates made solely with information from monitoring efforts. Probabilistic predictions of future chlorophyll levels on one reservoir are used to illustrate the cost savings that can be achieved by less extensive and rigorous monitoring methods within the BME framework. While BME methods have been applied in several environmental contexts, employing these methods as a means of integrating monitoring and modeling results, as well as application of this approach to the assessment of surface water monitoring networks, represent unexplored areas of research.
Nitrogen Plasma Optimization for High-Quality Dilute Nitrides
2005-02-01
Available online 1 February 2005Abstract Growth of GaInNAs by molecular beam epitaxy (MBE) generally requires a nitrogen plasma, which complicates growth...InGaAs and InGaAsP lasers. This paper addresses several of the challenges of plasma-assisted molecular beam epitaxy (MBE) of high-quality dilute nitrides...A.L. Holmes, Using beam flux monitor as Langmuir probe for plasma-assisted molecular beam epitaxy , J. Vac. Sci. Technol. B, in press.
[Research advances in water quality monitoring technology based on UV-Vis spectrum analysis].
Wei, Kang-Lin; Wen, Zhi-yu; Wu, Xin; Zhang, Zhong-Wei; Zeng, Tian-Ling
2011-04-01
The application of spectral analysis to water quality monitoring is an important developing trend in the field of modern environment monitoring technology. The principle and characteristic of water quality monitoring technology based on UV-Vis spectrum analysis are briefly reviewed. And the research status and advances are introduced from two aspects, on-line monitoring and in-situ monitoring. Moreover, the existent key technical problems are put forward. Finally, the technology trends of multi-parameter water quality monitoring microsystem and microsystem networks based on microspectrometer are prospected, which has certain reference value for the research and development of environmental monitoring technology and modern scientific instrument in the authors' country.
Noninvasive pH monitoring of platelet concentrates: a large field test.
Gkoumassi, Effimia; Klein-Bosgoed, Christa; Dijkstra-Tiekstra, Margriet J; de Korte, Dirk; de Wildt-Eggen, Janny
2013-10-01
Developing new quality control methods for platelet concentrates (PCs) can contribute to increasing transfusion safety and efficiency. The aim of this study was to investigate in a large field test the quality of expired PCs and whether 100% noninvasive pH monitoring can be used to predict PC quality. The pH of 13,693 PCs produced for transfusion was monitored daily using Blood Storage, Inc.'s pH sterile, automated fluoroscopic evaluation technology. Upon indication of compromised quality or expiration, PCs were returned and in vitro tests were performed. A total of 998 PCs were returned, of which 962 outdated, 26 had a positive BacT/ALERT reaction, seven had aggregates, one was without swirl, one had low pH, and one had high pH. BacT/ALERT was faster in identifying bacterial contamination than pH measurements. The pH at the end of the storage period was significantly lower than at the beginning. In vitro tests indicated that while the PC quality was acceptable upon expiration, it rapidly declined after expiration. In this setting where the vast majority of PCs were of good quality and within acceptable pH limits, daily, noninvasive routine pH measurement has limited added value in identifying quality-compromised PCs. © 2013 Sanquin Research. Transfusion © 2013 American Association of Blood Banks.
Richer, Eric E.; Baron, Jill S.
2011-01-01
The Loch Vale watershed project is a long-term research and monitoring program located in Rocky Mountain National Park that addresses watershed-scale ecosystem processes, particularly as they respond to atmospheric deposition and climate variability. Measurements of precipitation depth, precipitation chemistry, discharge, and surface-water quality are made within the watershed and elsewhere in Rocky Mountain National Park. As data collected for the program are used by resource managers, scientists, policy makers, and students, it is important that all data collected in Loch Vale watershed meet high standards of quality. In this report, data quality was evaluated for precipitation, discharge, and surface-water chemistry measurements collected during 2003-09. Equipment upgrades were made at the Loch Vale National Atmospheric Deposition Program monitoring site to improve precipitation measurements and evaluate variability in precipitation depth and chemistry. Additional solar panels and batteries have been installed to improve the power supply, and data completeness, at the NADP site. As a result of equipment malfunction, discharge data for the Loch Outlet were estimated from October 18, 2005, to August 17, 2006. Quality-assurance results indicate that more than 98 percent of all surface-water chemistry measurements were accurate and precise. Records that did not meet quality criteria were removed from the database. Measurements of precipitation depth, precipitation chemistry, discharge, and surface-water quality were all sufficiently complete and consistent to support project data needs.
Technology Transfer Opportunities: Automated Ground-Water Monitoring
Smith, Kirk P.; Granato, Gregory E.
1997-01-01
Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.
Di Guardo, Andrea; Finizio, Antonio
2018-01-01
In the last decades, several monitoring programs were established as an effect of EU Directives addressing the quality of water resources (drinking water, groundwater and surface water). Plant Protection Products (PPPs) are an obvious target of monitoring activities, since they are directly released into the environment. One of the challenges in managing the risk of pesticides at the territorial scale is identifying the locations in water bodies needing implementation of risk mitigation measures. In this, the national pesticides monitoring plans could be very helpful. However, monitoring of pesticides is a challenging task because of the high number of registered pesticides, cost of analyses, and the periodicity of sampling related to pesticide application and use. Extensive high-quality data-sets are consequently often missing. More in general, the information that can be obtained from monitoring studies are frequently undervalued by risk managers. In this study, we propose a new methodology providing indications about the need to implement mitigation measures in stretches of surface water bodies on a territory by combining historical series of monitoring data and GIS. The methodology is articulated in two distinct phases: a) acquisition of monitoring data and setting-up of informative layers of georeferenced data (phase 1) and b) statistical and expert analysis for the identification of areas where implementation of limitation or mitigation measures are suggested (phase 2). Our methodology identifies potentially vulnerable water bodies, considering temporal contamination trends and relative risk levels at selected monitoring stations. A case study is presented considering glyphosate monitoring data in Lombardy Region (Northern of Italy) for the 2008-2014 period. Copyright © 2017 Elsevier B.V. All rights reserved.
A conceptual ground-water-quality monitoring network for San Fernando Valley, California
Setmire, J.G.
1985-01-01
A conceptual groundwater-quality monitoring network was developed for San Fernando Valley to provide the California State Water Resources Control Board with an integrated, basinwide control system to monitor the quality of groundwater. The geology, occurrence and movement of groundwater, land use, background water quality, and potential sources of pollution were described and then considered in designing the conceptual monitoring network. The network was designed to monitor major known and potential point and nonpoint sources of groundwater contamination over time. The network is composed of 291 sites where wells are needed to define the groundwater quality. The ideal network includes four specific-purpose networks to monitor (1) ambient water quality, (2) nonpoint sources of pollution, (3) point sources of pollution, and (4) line sources of pollution. (USGS)
Whitman, Richard L.; Nevers, Meredith B.
2004-01-01
Monitoring beaches for recreational water quality is becoming more common, but few sampling designs or policy approaches have evaluated the efficacy of monitoring programs. The authors intensively sampled water for E. coli (N=1770) at 63rd Street Beach, Chicago for 6 months in 2000 in order to (1) characterize spatial-temporal trends, (2) determine between and within transect variation, and (3) estimate sample size requirements and determine sampling reliability.E. coli counts were highly variable within and between sampling sites but spatially and diurnally autocorrelated. Variation in counts decreased with water depth and time of day. Required number of samples was high for 70% precision around the critical closure level (i.e., 6 within or 24 between transect replicates). Since spatial replication may be cost prohibitive, composite sampling is an alternative once sources of error have been well defined. The results suggest that beach monitoring programs may be requiring too few samples to fulfill management objectives desired. As the recreational water quality national database is developed, it is important that sampling strategies are empirically derived from a thorough understanding of the sources of variation and the reliability of collected data. Greater monitoring efficacy will yield better policy decisions, risk assessments, programmatic goals, and future usefulness of the information.
Promulgated quality assurance Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources
Effects of urbanization on stream water quality in the city of Atlanta, Georgia, USA
Peters, N.E.
2009-01-01
A long-term stream water quality monitoring network was established in the city of Atlanta, Georgia during 2003 to assess baseline water quality conditions and the effects of urbanization on stream water quality. Routine hydrologically based manual stream sampling, including several concurrent manual point and equal width increment sampling, was conducted ???12 times annually at 21 stations, with drainage areas ranging from 3.7 to 232 km2. Eleven of the stations are real-time (RT) stations having continuous measures of stream stage/ discharge, pH, dissolved oxygen, specific conductance, water temperature and turbidity, and automatic samplers for stormwater collection. Samples were analyzed for field parameters, and a broad suite of water quality and sediment-related constituents. Field parameters and concentrations of major ions, metals, nutrient species and coliform bacteria among stations were evaluated and with respect to watershed characteristics and plausible sources from 2003 through September 2007. Most constituent concentrations are much higher than nearby reference streams. Concentrations are statistically different among stations for several constituents, despite high variability both within and among stations. Routine manual sampling, automatic sampling during stormflows and RT water quality monitoring provided sufficient information about urban stream water quality variability to evaluate causes of water quality differences among streams. Fecal coliform bacteria concentrations of most samples exceeded Georgia's water quality standard for any water-usage class. High chloride concentrations occur at three stations and are hypothesized to be associated with discharges of chlorinated combined sewer overflows, drainage of swimming pool(s) and dissolution and transport during rainstorms of CaCl2, a deicing salt applied to roads during winter storms. One stream was affected by dissolution and transport of ammonium alum [NH4Al(SO4)2] from an alum-manufacturing plant; streamwater has low pH (<5), low alkalinity and high metals concentrations. Several trace metals exceed acute and chronic water quality standards and high concentrations are attributed to washoff from impervious surfaces.
NASA Astrophysics Data System (ADS)
Forrester, H.; Roop, H. A.; Clow, D. W.
2011-12-01
Backpackers and pack animals, primarily horses and mules, may impair water quality in high-use zones of federally designated wilderness areas within Sequoia and Kings Canyon National Parks (SEKI). Impacts include erosion from trails, campsites and grazing sites, which increases suspended sediment concentrations and turbidity in downstream water bodies; and fecal matter that may be washed into surface waters during rainstorms or snowmelt periods. The fecal matter also may contain pathogenic bacteria such as Escherichia coli (E. coli) that can pose a health threat to humans. This study aims to establish a working methodology to document and assess effects from backpackers and stock use on physical, chemical and biological water quality parameters. In July 2010, monitoring stations were established within the high-use Crabtree Ranger Station zone. Sites were selected to represent high backpacker use, high pack-animal use, and background conditions. Monitoring stations are instrumented to continuously record water level, temperature, and turbidity and to automatically collect storm samples. Water samples are analyzed for dissolved and particulate nutrients, suspended sediment, and E. coli concentrations. Preliminary data show E. coli counts averaged 4.5 Colony Forming Units/100ml (CFUs) at the high backpacker use, 29.0 CFUs at the high-pack animal use, and 3.4 CFUs at the background sites. Results from the nutrients and suspended sediment analyses are pending. Data collection continued throughout the 2011 field season, with the objective of better quantifying differences in water quality among the study sites.
Airborne particle monitoring in clean room environments for stem cell cultures.
Cobo, Fernando; Grela, David; Concha, Angel
2008-01-01
Modern high-technology industrial practices like pharmaceutical and stem cell line production demand high-quality environmental conditions to avoid particle contamination in the final product. Particles are important because their presence can affect both the output and the productivity and because they can have repercussion on human health. In this kind of production practice it is necessary to implement optimal methods for particle management and to introduce an environmental monitoring program. This should also address the regional regulatory requirements and will depend on local conditions in each processing center. Each center must evaluate its specific needs and establish appropriate monitoring procedures.
Cistern and planter box monitoring in Camden, NJ revisited ...
The Camden County Municipal Utilities Authority installed green infrastructure Stormwater Control Measures at multiple locations around the city of Camden, NJ. The Stormwater Control Measures include raised downspout planter boxes and cisterns. EPA is monitoring a subset of the locations to document the performance of individual Stormwater Control Measures. The selected monitoring sites include two sets of raised downspout planter boxes and five cisterns. These Stormwater Control Measures are being monitored: to investigate their hydrologic performances, to document water consumption patterns of cisterns for a better understanding of the supply and demand relationship, and to analyze cistern water quality. The continuous electronic monitoring devices included time domain reflectometers, rain gauges and pressure transducers. EPA decided to monitor these Stormwater Control Measures for three years and second year monitoring is ongoing. Monitoring data present the internal water flow patterns and media saturation frequency of the raised planter boxes and the capture ratio, water use patterns and water quality analysis of cisterns. Second year monitoring shows larger capture ratio for cisterns compared to the first year data and higher metal concentration at one site. The high metal concentration was later resolved by flushing the cistern and resampling. The presentation will summarize the comparison between first and second year data, providing results from the
Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa
2015-02-09
False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.
Ion current detector for high pressure ion sources for monitoring separations
Smith, R.D.; Wahl, J.H.; Hofstadler, S.A.
1996-08-13
The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source. 7 figs.
Ion current detector for high pressure ion sources for monitoring separations
Smith, Richard D.; Wahl, Jon H.; Hofstadler, Steven A.
1996-01-01
The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source.
Remote sensing of water quality and contaminants in the California Bay-Delta
NASA Astrophysics Data System (ADS)
Fichot, C. G.; Downing, B. D.; Windham-Myers, L.; Marvin-DiPasquale, M. C.; Bergamaschi, B. A.; Thompson, D. R.; Gierach, M. M.
2014-12-01
The California Bay-Delta is a highly altered ecosystem largely reclaimed from wetlands for agriculture, and millions of acres of farmland and Californians rely on the Bay-Delta for their water supply. The Bay-Delta also harbors important habitats for many organisms, including commercial and endangered species. Recently, the Delta Stewardship Council developed a two component mission (coequal goals) to 1) provide a more reliable water supply for California while 2) protecting, restoring, and enhancing the Bay-Delta ecosystem. Dissolved organic carbon, turbidity, and contaminants such as methylmercury represent important water quality issues for water management and in the context of wetland restoration in the Bay-Delta, and can threaten the achievement of the coequal goals. Here, we use field measurements of optical properties, chemical analyses, and remotely sensed data acquired with the airborne Portable Remote Imaging SpectroMeter (PRISM ; http://prism.jpl.nasa.gov/index.html) to demonstrate these water quality parameters and the study of their dynamics in the Bay-Delta are amenable to remote sensing. PRISM provides high signal-to-noise, high spatial resolution (~2 m), hyperspectral measurements of remote-sensing reflectance in the 350-1050 nm range, and therefore has the adequate resolutions for water quality monitoring in inland, optically complex waters. Remote sensing of water quality will represent a valuable complement to existing in situ water quality monitoring programs in this region and will help with decision-making to achieve the co-equal goals.
The Improvement of Spatial-Temporal PM2.5 Resolution in Taiwan by Using Data Assimilation Method
NASA Astrophysics Data System (ADS)
Lin, Yong-Qing; Lin, Yuan-Chien
2017-04-01
Forecasting air pollution concentration, e.g., the concentration of PM2.5, is of great significance to protect human health and the environment. Accurate prediction of PM2.5 concentrations is limited in number and the data quality of air quality monitoring stations. The spatial and temporal variations of PM2.5 concentrations are measured by 76 National Air Quality Monitoring Stations (built by the TW-EPA) in Taiwan. The National Air Quality Monitoring Stations are costly and scarce because of the highly precise instrument and their size. Therefore, many places still out of the range of National Air Quality Monitoring Stations. Recently, there are an enormous number of portable air quality sensors called "AirBox" developed jointly by the Taiwan government and a private company. By virtue of its price and portative, the AirBox can provide higher resolution of space-time PM2.5 measurement. However, the spatiotemporal distribution and data quality are different between AirBox and National Air Quality Monitoring Stations. To integrate the heterogeneous PM2.5 data, the data assimilation method should be performed before further analysis. In this study, we propose a data assimilation method based on Ensemble Kalman Filter (EnKF), which is a variant of classic Kalman Filter, can be used to combine additional heterogeneous data from different source while modeling to improve the estimation of spatial-temporal PM2.5 concentration. The assimilation procedure uses the advantages of the two kinds of heterogeneous data and merges them to produce the final estimation. The results have shown that by combining AirBox PM2.5 data as additional information in our model based EnKF can bring the better estimation of spatial-temporal PM2.5 concentration and improve the it's space-time resolution. Under the approach proposed in this study, higher spatial-temporal resoultion could provide a very useful information for a better spatial-temporal data analysis and further environmental management, such as air pollution source localization and micro-scale air pollution analysis. Keywords: PM2.5, Data Assimilation, Ensemble Kalman Filter, Air Quality
McMillan, Lindsay A; Rivett, Michael O; Wealthall, Gary P; Zeeb, Peter; Dumble, Peter
2018-03-01
Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Variation of organic matter quantity and quality in streams at Critical Zone Observatory watersheds
Miller, Matthew P.; Boyer, Elizabeth W.; McKnight, Diane M.; Brown, Michael G.; Gabor, Rachel S.; Hunsaker, Carolyn T.; Iavorivska , Lidiia; Inamdar, Shreeram; Kaplan, Louis A.; Johnson, Dale W.; Lin, Henry; McDowell, William H.; Perdrial, Julia N.
2016-01-01
The quantity and chemical composition of dissolved organic matter (DOM) in surface waters influence ecosystem processes and anthropogenic use of freshwater. However, despite the importance of understanding spatial and temporal patterns in DOM, measures of DOM quality are not routinely included as part of large-scale ecosystem monitoring programs and variations in analytical procedures can introduce artifacts. In this study, we used consistent sampling and analytical methods to meet the objective of defining variability in DOM quantity and quality and other measures of water quality in streamflow issuing from small forested watersheds located within five Critical Zone Observatory sites representing contrasting environmental conditions. Results show distinct separations among sites as a function of water quality constituents. Relationships among rates of atmospheric deposition, water quality conditions, and stream DOM quantity and quality are consistent with the notion that areas with relatively high rates of atmospheric nitrogen and sulfur deposition and high concentrations of divalent cations result in selective transport of DOM derived from microbial sources, including in-stream microbial phototrophs. We suggest that the critical zone as a whole strongly influences the origin, composition, and fate of DOM in streams. This study highlights the value of consistent DOM characterization methods included as part of long-term monitoring programs for improving our understanding of interactions among ecosystem processes as controls on DOM biogeochemistry.
Wilcox, S.; Andreas, A.
2010-09-27
The U.S. Department of Energy's National Renewable Energy Laboratory collaborates with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
NASA Astrophysics Data System (ADS)
Wilcox, Steve; Myers, Daryl
2009-08-01
The U.S. Department of Energy's National Renewable Energy Laboratory has embarked on a collaborative effort with the solar industry to establish high quality solar and meteorological measurements. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of concentrating solar thermal power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result will be high quality data sets to support the financing, design, and monitoring of large scale solar power projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.
A High-Resolution Minimicroscope System for Wireless Real-Time Monitoring.
Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung
2018-07-01
Compact, cost-effective, and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless minimicroscope with resolution up to 2592 × 1944 pixels and speed up to 90 f/s. The minimicroscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed minimicroscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 h. In addition, the minimicroscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the minimicroscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed minimicroscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high-resolution minimicroscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.
40 CFR 63.10020 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2014 CFR
2014-07-01
...-of-control periods, or required monitoring system quality assurance or control activities in... monitoring system quality assurance or quality control activities including, as applicable, calibration... collect data according to this section and the site-specific monitoring plan required by § 63.10000(d). (b...
40 CFR 60.2735 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2014 CFR
2014-07-01
... activities including, as applicable, calibration checks and required zero and span adjustments. A monitoring... monitoring system quality assurance or control activities in calculations used to report emissions or...-control periods, and required monitoring system quality assurance or quality control activities including...
40 CFR 63.10020 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2012 CFR
2012-07-01
...-of-control periods, or required monitoring system quality assurance or control activities in... monitoring system quality assurance or quality control activities including, as applicable, calibration... collect data according to this section and the site-specific monitoring plan required by § 63.10000(d). (b...
40 CFR 60.2735 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2013 CFR
2013-07-01
... activities including, as applicable, calibration checks and required zero and span adjustments. A monitoring... monitoring system quality assurance or control activities in calculations used to report emissions or...-control periods, and required monitoring system quality assurance or quality control activities including...
40 CFR 63.10020 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2013 CFR
2013-07-01
...-of-control periods, or required monitoring system quality assurance or control activities in... monitoring system quality assurance or quality control activities including, as applicable, calibration... collect data according to this section and the site-specific monitoring plan required by § 63.10000(d). (b...
Rasmussen, Teresa J.; Bennett, Trudy J.; Foster, Guy M.; Graham, Jennifer L.; Putnam, James E.
2014-01-01
As the Nation’s largest water, earth, and biological science and civilian mapping information agency, the U.S. Geological Survey is relied on to collect high-quality data, and produce factual and impartial interpretive reports. This quality-assurance and data-management plan provides guidance for water-quality activities conducted by the Kansas Water Science Center. Policies and procedures are documented for activities related to planning, collecting, storing, documenting, tracking, verifying, approving, archiving, and disseminating water-quality data. The policies and procedures described in this plan complement quality-assurance plans for continuous water-quality monitoring, surface-water, and groundwater activities in Kansas.
40 CFR 130.4 - Water quality monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...
40 CFR 130.4 - Water quality monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...
40 CFR 130.4 - Water quality monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 23 2013-07-01 2013-07-01 false Water quality monitoring. 130.4 Section 130.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY PLANNING AND MANAGEMENT § 130.4 Water quality monitoring. (a) In accordance with section 106(e)(1...
Citizen Science Opportunities for Monitoring Air Quality Fact Sheet
The Citizen Science Opportunities for Monitoring Air Quality fact sheet provides information on what citizen science is and the tools and resources available for citizen scientists interested in monitoring air quality.
D'Amore, Francesco; Bencardino, Mariantonia; Cinnirella, Sergio; Sprovieri, Francesca; Pirrone, Nicola
2015-08-01
The overall goal of the on-going Global Mercury Observation System (GMOS) project is to develop a coordinated global monitoring network for mercury, including ground-based, high altitude and sea level stations. In order to ensure data reliability and comparability, a significant effort has been made to implement a centralized system, which is designed to quality assure and quality control atmospheric mercury datasets. This system, GMOS-Data Quality Management (G-DQM), uses a web-based approach with real-time adaptive monitoring procedures aimed at preventing the production of poor-quality data. G-DQM is plugged on a cyberinfrastructure and deployed as a service. Atmospheric mercury datasets, produced during the first-three years of the GMOS project, are used as the input to demonstrate the application of the G-DQM and how it identifies a number of key issues concerning data quality. The major issues influencing data quality are presented and discussed for the GMOS stations under study. Atmospheric mercury data collected at the Longobucco (Italy) station is used as a detailed case study.
Indoor Air Quality in Central Appalachia Homes Impacted by Wood and Coal Use
Paulin, Laura M.; Williams, D’Ann; Oberweiser, Charles; Diette, Gregory B.; Breysse, Patrick N.; McCormack, Meredith M.; Matsui, Elizabeth C.; Peng, Roger; Metts, Tricia A.; Hansel, Nadia N.
2016-01-01
Though the high prevalence of biomass fuel use in the developing world is widely known, the use of burning biomass for cooking and heating in the developed world is under-recognized. Combustion materials including coal and wood are also used for heating in some areas of the United States. We conducted a pilot study to assess the feasibility of conducting indoor environmental monitoring in rural Appalachia. We sought to explore the type of biomass being used for home heating and its impact upon indoor air quality in non-heating and heating seasons. Residential indoor air monitoring for particulate matter (PM) and nitrogen dioxide (NO2) was conducted in Lee County, Virginia. Homes had evidence of poor indoor air quality with high concentrations of indoor PM and a large burden of cigarette smoking. Further characterization of indoor combustion material use in this region to determine the health impacts associated with such exposures is warranted. PMID:27738549
A method of monitoring contact (pointed) welding
NASA Astrophysics Data System (ADS)
Bessonov, V. B.; Staroverov, N. E.; Larionov, I. A.; Guk, K. K.; Obodovskiy, A. V.
2018-02-01
The technology of welding parts of different thicknesses from various materials is improved, which is why the range of applied types and methods of welding is constantly expanding. In this regard, the issue of monitoring welded joints is particularly acute. The goal was: to develop a method of non-destructive radiographic inspection of point welds with a high accuracy rating of its quality.
ERIC Educational Resources Information Center
Van Norman, Ethan R.; Christ, Theodore J.; Zopluoglu, Cengiz
2013-01-01
This study examined the effect of baseline estimation on the quality of trend estimates derived from Curriculum Based Measurement of Oral Reading (CBM-R) progress monitoring data. The authors used a linear mixed effects regression (LMER) model to simulate progress monitoring data for schedules ranging from 6-20 weeks for datasets with high and low…
David, Arthur; Tournoud, Marie-George; Perrin, Jean-Louis; Rosain, David; Rodier, Claire; Salles, Christian; Bancon-Montigny, Chrystelle; Picot, Bernadette
2013-03-01
This paper analyzes how changes in hydrological conditions can affect the water quality of a temporary river that receives direct inputs of sewage effluents. Data from 12 spatial surveys of the Vène river were examined. Physico-chemical parameters, major ion, and nutrient concentrations were measured. Analyses of variance (ANOVA) and multivariate analyses were performed. ANOVA revealed significant spatial differences for conductivity and major ion but no significant spatial differences for nutrient concentrations even if higher average concentrations were observed at stations located downstream from sewage effluent discharge points. Significant temporal differences were observed among all the parameters. Karstic springs had a marked dilution effect on the direct disposal of sewage effluents. During high-flow periods, nutrient concentrations were high to moderate whereas nutrient concentrations ranged from moderate to bad at stations located downstream from the direct inputs of sewage effluents during low-flow periods. Principal component analysis showed that water quality parameters that explained the water quality of the Vène river were highly dependent on hydrological conditions. Cluster analysis showed that when the karstic springs were flowing, water quality was homogeneous all along the river, whereas when karstic springs were dry, water quality at the monitoring stations was more fragmented. These results underline the importance of considering hydrological conditions when monitoring the water quality of temporary rivers. In view of the pollution observed in the Vène river, "good water chemical status" can probably only be achieved by improving the management of sewage effluents during low-flow periods.
Factors controlling stream water nitrate and phosphor loads during precipitation events
NASA Astrophysics Data System (ADS)
Rozemeijer, J.; van der Velde, Y.; van Geer, F.; de Rooij, G. H.; Broers, H.; Bierkens, M. F.
2009-12-01
Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Within regional surface water quality monitoring networks, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because this natural variability in surface water quality is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous records of stream water N and P concentrations to easier and cheaper to collect quantitative data on precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment we collected continuous measurements of precipitation, groundwater levels and tube drain discharges. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and multiple regression analysis were used to identify relations between the N and P response to the rainfall events and the quantitative event characteristics. We successfully used these relations to predict the N and P responses to events and to improve the interpolation between low frequency grab sample measurements. Incorporating the predicted concentration changes during high discharge events dramatically improved the precision of our load estimations.
Progress and lessons learned from water-quality monitoring networks
Myers, Donna N.; Ludtke, Amy S.
2017-01-01
Stream-quality monitoring networks in the United States were initiated and expanded after passage of successive federal water-pollution control laws from 1948 to 1972. The first networks addressed information gaps on the extent and severity of stream pollution and served as early warning systems for spills. From 1965 to 1972, monitoring networks expanded to evaluate compliance with stream standards, track emerging issues, and assess water-quality status and trends. After 1972, concerns arose regarding the ability of monitoring networks to determine if water quality was getting better or worse and why. As a result, monitoring networks adopted a hydrologic systems approach targeted to key water-quality issues, accounted for human and natural factors affecting water quality, innovated new statistical methods, and introduced geographic information systems and models that predict water quality at unmeasured locations. Despite improvements, national-scale monitoring networks have declined over time. Only about 1%, or 217, of more than 36,000 US Geological Survey monitoring sites sampled from 1975 to 2014 have been operated throughout the four decades since passage of the 1972 Clean Water Act. Efforts to sustain monitoring networks are important because these networks have collected information crucial to the description of water-quality trends over time and are providing information against which to evaluate future trends.
ERIC Educational Resources Information Center
Rojas, Natalia; Raver, Cybele; Morris, Pamela
2016-01-01
The purpose of this presentation is to describe some of the activities of a partnership forged between NYU researchers and senior leaders in NYC that was intended to provide research infrastructure and capacity-building solutions while also addressing jointly identified research questions about the "Pre-K for All" (PKA) program. The…
Kroening, Sharon E.
2008-01-01
Surface- and ground-water quality data from the Mosquito Lagoon Basin were compiled and analyzed to: (1) describe historical and current monitoring in the basin, (2) summarize surface- and ground-water quality conditions with an emphasis on identifying areas that require additional monitoring, and (3) develop a water-quality monitoring network to meet the goals of Canaveral National Seashore (a National Park) and to fill gaps in current monitoring. Water-quality data were compiled from the U.S. Environmental Protection Agency's STORET system, the U.S. Geological Survey's National Water Information System, or from the agency which collected the data. Most water-quality monitoring focused on assessing conditions in Mosquito Lagoon. Significant spatial and/or seasonal variations in water-quality constituents in the lagoon were quantified for pH values, fecal coliform bacteria counts, and concentrations of dissolved oxygen, total nitrogen, total phosphorus, chlorophyll-a, and total suspended solids. Trace element, pesticide, and ground-water-quality data were more limited. Organochlorine insecticides were the major class of pesticides analyzed. A surface- and ground-water-quality monitoring network was designed for the Mosquito Lagoon Basin which emphasizes: (1) analysis of compounds indicative of human activities, including pesticides and other trace organic compounds present in domestic and industrial waste; (2) greater data collection in the southern part of Mosquito Lagoon where spatial variations in water-quality constituents were quantified; and (3) additional ground-water-quality data collection in the surficial aquifer system and Upper Floridan aquifer. Surface-water-quality data collected as part of this network would include a fixed-station monitoring network of eight sites in the southern part of the basin, including a canal draining Oak Hill. Ground-water quality monitoring should be done routinely at about 20 wells in the surficial aquifer system and Upper Floridan aquifer, distributed between developed and undeveloped parts of the basin. Water samples collected should be analyzed for a wide range of constituents, including physical properties, nutrients, suspended sediment, and constituents associated with increased urban development such as pesticides, other trace organic compounds associated with domestic and industrial waste, and trace elements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lathrop, R.G. Jr.
1988-01-01
The utility of three operational satellite remote sensing systems, namely, the Landsat Thematic Mapper (TM), the SPOT High Resolution Visible (HRV) sensors and the NOAA Advanced Very High Resolution Radiometer (AVHRR), were evaluated as a means of estimating water quality and surface temperature. Empirical calibration through linear regression techniques was used to relate near-simultaneously acquired satellite radiance/reflectance data and water quality observations obtained in Green Bay and the nearshore waters of Lake Michigan. Four dates of TM and one date each of SPOT and AVHRR imagery/surface reference data were acquired and analyzed. Highly significant relationships were identified between the TMmore » and SPOT data and secchi disk depth, nephelometric turbidity, chlorophyll a, total suspended solids (TSS), absorbance, and surface temperature (TM only). The AVHRR data were not analyzed independently but were used for comparison with the TM data. Calibrated water quality image maps were input to a PC-based raster GIS package, EPPL7. Pattern interpretation and spatial analysis techniques were used to document the circulation dynamics and model mixing processes in Green Bay. A GIS facilitates the retrieval, query and spatial analysis of mapped information and provides the framework for an integrated operational monitoring system for the Great Lakes.« less
Quality of care in reproductive health programmes: education for quality improvement.
Kwast, B E
1998-09-01
The provision of high quality maternity care will make the difference between life and death or lifelong maiming for millions of pregnant women. Barriers preventing access to affordable, appropriate, acceptable and effective services, and lack of facilities providing high quality obstetric care result in about 1600 maternal deaths every day. Education in its broadest sense is required at all levels and sectors of society to enhance policy formulation that will strengthen programme commitment, improve services with a culturally sensitive approach and ensure appropriate delegation of responsibility to health staff at peripheral levels. This paper is the second in series of three which addresses quality of care. The first (Kwast 1998) contains an overview of concepts, assessments, barriers and improvements of quality of care. The third article will describe selected aspects of monitoring and evaluation of quality of care.
A ground-water-quality monitoring program for Nevada
Nowlin, Jon O.
1986-01-01
A program was designed for the systematic monitoring of ground-water quality in Nevada. Basic hydrologic and water-quality principles are discussed in the formulation of a rational approach to developing a statewide monitoring program. A review of ground-water monitoring efforts in Nevada through 1977 indicates that few requirements for an effective statewide program are being met. A suggested program has been developed that consists of five major elements: (1) A Background-Quality Network to assess the existing water quality in Nevada aquifers, (2) a Contamination Source Inventory of known or potential threats to ground-water quality, (3) Surveillance Networks to monitor ground-water quality in selected hydrographic areas, (4) Intensive Surveys of individual instances of known or potential ground-water contamination, and (5) Ground-Water Data File to manage data generated by the other monitoring elements. Two indices have been developed to help assign rational priorities for monitoring ground water in the 255 hydrographic areas of Nevada: (1) A Hydrographic-Area Priority Index for surveillance monitoring, and (2) A Development-Potential Index for background monitoring of areas with little or no current development. Requirements for efficient management of data from ground-water monitoring are discussed and the three major systems containing Nevada ground-water data are reviewed. More than 11,000 chemical analyses of ground water have been acquired from existing systems and incorporated into a prototype data base.
NASA Astrophysics Data System (ADS)
Vitali, Lina; Righini, Gaia; Piersanti, Antonio; Cremona, Giuseppe; Pace, Giandomenico; Ciancarella, Luisella
2017-12-01
Air backward trajectory calculations are commonly used in a variety of atmospheric analyses, in particular for source attribution evaluation. The accuracy of backward trajectory analysis is mainly determined by the quality and the spatial and temporal resolution of the underlying meteorological data set, especially in the cases of complex terrain. This work describes a new tool for the calculation and the statistical elaboration of backward trajectories. To take advantage of the high-resolution meteorological database of the Italian national air quality model MINNI, a dedicated set of procedures was implemented under the name of M-TraCE (MINNI module for Trajectories Calculation and statistical Elaboration) to calculate and process the backward trajectories of air masses reaching a site of interest. Some outcomes from the application of the developed methodology to the Italian Network of Special Purpose Monitoring Stations are shown to assess its strengths for the meteorological characterization of air quality monitoring stations. M-TraCE has demonstrated its capabilities to provide a detailed statistical assessment of transport patterns and region of influence of the site under investigation, which is fundamental for correctly interpreting pollutants measurements and ascertaining the official classification of the monitoring site based on meta-data information. Moreover, M-TraCE has shown its usefulness in supporting other assessments, i.e., spatial representativeness of a monitoring site, focussing specifically on the analysis of the effects due to meteorological variables.
Characterizing Intra-Urban Air Quality Gradients with a Spatially-Distributed Network
NASA Astrophysics Data System (ADS)
Zimmerman, N.; Ellis, A.; Schurman, M. I.; Gu, P.; Li, H.; Snell, L.; Gu, J.; Subramanian, R.; Robinson, A. L.; Apte, J.; Presto, A. A.
2016-12-01
City-wide air pollution measurements have typically relied on regulatory or research monitoring sites with low spatial density to assess population-scale exposure. However, air pollutant concentrations exhibit significant spatial variability depending on local sources and features of the built environment, which may not be well captured by the existing monitoring regime. To better understand urban spatial and temporal pollution gradients at 1 km resolution, a network of 12 real-time air quality monitoring stations was deployed beginning July 2016 in Pittsburgh, PA. The stations were deployed at sites along an urban-rural transect and in urban locations with a range of traffic, restaurant, and tall building densities to examine the impact of various modifiable factors. Measurements from the stationary monitoring stations were further supported by mobile monitoring, which provided higher spatial resolution pollutant measurements on nearby roadways and enabled routine calibration checks. The stationary monitoring measurements comprise ultrafine particle number (Aerosol Dynamics "MAGIC" CPC), PM2.5 (Met One Neighborhood PM Monitor), black carbon (Met One BC 1050), and a new low-cost air quality monitor, the Real-time Affordable Multi-Pollutant (RAMP) sensor package for measuring CO, NO2, SO2, O3, CO2, temperature and relative humidity. High time-resolution (sub-minute) measurements across the distributed monitoring network enable insight into dynamic pollutant behaviour. Our preliminary findings show that our instruments are sensitive to PM2.5 gradients exceeding 2 micro-grams per cubic meter and ultrafine particle gradients exceeding 1000 particles per cubic centimeter. Additionally, we have developed rigorous calibration protocols to characterize the RAMP sensor response and drift, as well as multiple linear regression models to convert sensor response into pollutant concentrations that are comparable to reference instrumentation.
NASA Astrophysics Data System (ADS)
Dash, Prasanjit; Ignatov, Alexander; Martin, Matthew; Donlon, Craig; Brasnett, Bruce; Reynolds, Richard W.; Banzon, Viva; Beggs, Helen; Cayula, Jean-Francois; Chao, Yi; Grumbine, Robert; Maturi, Eileen; Harris, Andy; Mittaz, Jonathan; Sapper, John; Chin, Toshio M.; Vazquez-Cuervo, Jorge; Armstrong, Edward M.; Gentemann, Chelle; Cummings, James; Piollé, Jean-François; Autret, Emmanuelle; Roberts-Jones, Jonah; Ishizaki, Shiro; Høyer, Jacob L.; Poulter, Dave
2012-11-01
There are a growing number of level 4 (L4; gap-free gridded) sea surface temperature (SST) products generated by blending SST data from various sources which are available for use in a wide variety of operational and scientific applications. In most cases, each product has been developed for a specific user community with specific requirements guiding the design of the product. Consequently differences between products are implicit. In addition, anomalous atmospheric conditions, satellite operations and production anomalies may occur which can introduce additional differences. This paper describes a new web-based system called the L4 SST Quality Monitor (L4-SQUAM) developed to monitor the quality of L4 SST products. L4-SQUAM intercompares thirteen L4 products with 1-day latency in an operational environment serving the needs of both L4 SST product users and producers. Relative differences between products are computed and visualized using maps, histograms, time series plots and Hovmöller diagrams, for all combinations of products. In addition, products are compared to quality controlled in situ SST data (available from the in situ SST Quality Monitor, iQUAM, companion system) in a consistent manner. A full history of products statistics is retained in L4-SQUAM for time series analysis. L4-SQUAM complements the two other Group for High Resolution SST (GHRSST) tools, the GHRSST Multi Product Ensemble (GMPE) and the High Resolution Diagnostic Data Set (HRDDS) systems, documented in part 1 of this paper and elsewhere, respectively. Our results reveal significant differences between SST products in coastal and open ocean areas. Differences of >2 °C are often observed at high latitudes partly due to different treatment of the sea-ice transition zone. Thus when an ice flag is available, the intercomparisons are performed in two ways: including and excluding ice-flagged grid points. Such differences are significant and call for a community effort to understand their root cause and ensure consistency between SST products. Future work focuses on including the remaining daily L4 SST products, accommodating for newer L4 SSTs which resolve the diurnal variability and evaluating retrospectively regenerated L4 SSTs to support satellite data reprocessing efforts aimed at generating improved SST Climate Data Records.
2012-01-01
Background High quality program data is critical for managing, monitoring, and evaluating national HIV treatment programs. By 2009, the Malawi Ministry of Health had initiated more than 270,000 patients on HIV treatment at 377 sites. Quarterly supervision of these antiretroviral therapy (ART) sites ensures high quality care, but the time currently dedicated to exhaustive record review and data cleaning detracts from other critical components. The exhaustive record review is unlikely to be sustainable long term because of the resources required and increasing number of patients on ART. This study quantifies the current levels of data quality and evaluates Lot Quality Assurance Sampling (LQAS) as a tool to prioritize sites with low data quality, thus lowering costs while maintaining sufficient quality for program monitoring and patient care. Methods In January 2010, a study team joined supervision teams at 19 sites purposely selected to reflect the variety of ART sites. During the exhaustive data review, the time allocated to data cleaning and data discrepancies were documented. The team then randomly sampled 76 records from each site, recording secondary outcomes and the time required for sampling. Results At the 19 sites, only 1.2% of records had discrepancies in patient outcomes and 0.4% in treatment regimen. However, data cleaning took 28.5 hours in total, suggesting that data cleaning for all 377 ART sites would require over 350 supervision-hours quarterly. The LQAS tool accurately identified the sites with the low data quality, reduced the time for data cleaning by 70%, and allowed for reporting on secondary outcomes. Conclusions Most sites maintained high quality records. In spite of this, data cleaning required significant amounts of time with little effect on program estimates of patient outcomes. LQAS conserves resources while maintaining sufficient data quality for program assessment and management to allow for quality patient care. PMID:22776745
Hedt-Gauthier, Bethany L; Tenthani, Lyson; Mitchell, Shira; Chimbwandira, Frank M; Makombe, Simon; Chirwa, Zengani; Schouten, Erik J; Pagano, Marcello; Jahn, Andreas
2012-07-09
High quality program data is critical for managing, monitoring, and evaluating national HIV treatment programs. By 2009, the Malawi Ministry of Health had initiated more than 270,000 patients on HIV treatment at 377 sites. Quarterly supervision of these antiretroviral therapy (ART) sites ensures high quality care, but the time currently dedicated to exhaustive record review and data cleaning detracts from other critical components. The exhaustive record review is unlikely to be sustainable long term because of the resources required and increasing number of patients on ART. This study quantifies the current levels of data quality and evaluates Lot Quality Assurance Sampling (LQAS) as a tool to prioritize sites with low data quality, thus lowering costs while maintaining sufficient quality for program monitoring and patient care. In January 2010, a study team joined supervision teams at 19 sites purposely selected to reflect the variety of ART sites. During the exhaustive data review, the time allocated to data cleaning and data discrepancies were documented. The team then randomly sampled 76 records from each site, recording secondary outcomes and the time required for sampling. At the 19 sites, only 1.2% of records had discrepancies in patient outcomes and 0.4% in treatment regimen. However, data cleaning took 28.5 hours in total, suggesting that data cleaning for all 377 ART sites would require over 350 supervision-hours quarterly. The LQAS tool accurately identified the sites with the low data quality, reduced the time for data cleaning by 70%, and allowed for reporting on secondary outcomes. Most sites maintained high quality records. In spite of this, data cleaning required significant amounts of time with little effect on program estimates of patient outcomes. LQAS conserves resources while maintaining sufficient data quality for program assessment and management to allow for quality patient care.
The State of Sensor Technology and Air Quality Monitoring
Produces data of known value and highly reliableStationary- cannot be easily relocatedInstruments are often large and require a building to support their operationExpensive to purchase and operate (typically > $20K each)Requires frequent visits by highly trained staff to check on...
Source Water Quality Monitoring
Presentation will provide background information on continuous source water monitoring using online toxicity monitors and cover various tools available. Conceptual and practical aspects of source water quality monitoring will be discussed.
Li, Haitao; Boling, C Sam; Mason, Andrew J
2016-08-01
Airborne pollutants are a leading cause of illness and mortality globally. Electrochemical gas sensors show great promise for personal air quality monitoring to address this worldwide health crisis. However, implementing miniaturized arrays of such sensors demands high performance instrumentation circuits that simultaneously meet challenging power, area, sensitivity, noise and dynamic range goals. This paper presents a new multi-channel CMOS amperometric ADC featuring pixel-level architecture for gas sensor arrays. The circuit combines digital modulation of input currents and an incremental Σ∆ ADC to achieve wide dynamic range and high sensitivity with very high power efficiency and compact size. Fabricated in 0.5 [Formula: see text] CMOS, the circuit was measured to have 164 dB cross-scale dynamic range, 100 fA sensitivity while consuming only 241 [Formula: see text] and 0.157 [Formula: see text] active area per channel. Electrochemical experiments with liquid and gas targets demonstrate the circuit's real-time response to a wide range of analyte concentrations.
40 CFR 60.2735 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2012 CFR
2012-07-01
... monitoring malfunctions, associated repairs, and required quality assurance or quality control activities for... periods, or required monitoring system quality assurance or control activities in calculations used to... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Is there a minimum amount of monitoring...
NASA Astrophysics Data System (ADS)
Al Hadhrami, Tawfik; Nightingale, James M.; Wang, Qi; Grecos, Christos
2014-05-01
In emergency situations, the ability to remotely monitor unfolding events using high-quality video feeds will significantly improve the incident commander's understanding of the situation and thereby aids effective decision making. This paper presents a novel, adaptive video monitoring system for emergency situations where the normal communications network infrastructure has been severely impaired or is no longer operational. The proposed scheme, operating over a rapidly deployable wireless mesh network, supports real-time video feeds between first responders, forward operating bases and primary command and control centers. Video feeds captured on portable devices carried by first responders and by static visual sensors are encoded in H.264/SVC, the scalable extension to H.264/AVC, allowing efficient, standard-based temporal, spatial, and quality scalability of the video. A three-tier video delivery system is proposed, which balances the need to avoid overuse of mesh nodes with the operational requirements of the emergency management team. In the first tier, the video feeds are delivered at a low spatial and temporal resolution employing only the base layer of the H.264/SVC video stream. Routing in this mode is designed to employ all nodes across the entire mesh network. In the second tier, whenever operational considerations require that commanders or operators focus on a particular video feed, a `fidelity control' mechanism at the monitoring station sends control messages to the routing and scheduling agents in the mesh network, which increase the quality of the received picture using SNR scalability while conserving bandwidth by maintaining a low frame rate. In this mode, routing decisions are based on reliable packet delivery with the most reliable routes being used to deliver the base and lower enhancement layers; as fidelity is increased and more scalable layers are transmitted they will be assigned to routes in descending order of reliability. The third tier of video delivery transmits a high-quality video stream including all available scalable layers using the most reliable routes through the mesh network ensuring the highest possible video quality. The proposed scheme is implemented in a proven simulator, and the performance of the proposed system is numerically evaluated through extensive simulations. We further present an in-depth analysis of the proposed solutions and potential approaches towards supporting high-quality visual communications in such a demanding context.
Power, Christopher; Ramasamy, Murugan; MacAskill, Devin; Shea, Joseph; MacPhee, Joseph; Mayich, David; Baechler, Fred; Mkandawire, Martin
2017-12-01
Cover systems are commonly placed over waste rock piles (WRPs) to limit atmospheric water and oxygen ingress and control the generation and release of acid mine drainage (AMD) to the receiving environment. Although covers containing geomembranes such as high-density polyethylene (HDPE) exhibit the attributes to be highly effective, there are few, if any, published studies monitoring their performance at full-scale WRPs. In 2011, a HDPE cover was installed over the Scotchtown Summit WRP in Nova Scotia, Canada, and extensive field performance monitoring was conducted over the next five years. A range of parameters within the atmosphere, cover, waste rock, groundwater and surface water, were monitored and integrated into a comprehensive hydrogeochemical conceptual model to assess (i) atmospheric ingress to the waste rock, (ii) waste rock acidity and depletion and (iii) evolution of groundwater and surface water quality. Results demonstrate that the cover is effective and meeting site closure objectives. Depletion in oxygen influx resulted in slower sulphide oxidation and AMD generation, while a significant reduction in water influx (i.e. 512 to 50 mm/year) resulted in diminished AMD release. Consistent improvements in groundwater quality (decrease in sulphate and metals; increase in pH) beneath and downgradient of the WRP were observed. Protection and/or significant improvement in surface water quality was evident in all surrounding watercourses due to the improved groundwater plume and elimination of contaminated runoff over previously exposed waste rock. A variably saturated flow and contaminant transport model is currently being developed to predict long-term cover system performance.
Wang, Junxiao; Wang, Xiaorui; Zhou, Shenglu; Wu, Shaohua; Zhu, Yan; Lu, Chunfeng
2016-01-01
With China’s rapid economic development, the reduction in arable land has emerged as one of the most prominent problems in the nation. The long-term dynamic monitoring of arable land quality is important for protecting arable land resources. An efficient practice is to select optimal sample points while obtaining accurate predictions. To this end, the selection of effective points from a dense set of soil sample points is an urgent problem. In this study, data were collected from Donghai County, Jiangsu Province, China. The number and layout of soil sample points are optimized by considering the spatial variations in soil properties and by using an improved simulated annealing (SA) algorithm. The conclusions are as follows: (1) Optimization results in the retention of more sample points in the moderate- and high-variation partitions of the study area; (2) The number of optimal sample points obtained with the improved SA algorithm is markedly reduced, while the accuracy of the predicted soil properties is improved by approximately 5% compared with the raw data; (3) With regard to the monitoring of arable land quality, a dense distribution of sample points is needed to monitor the granularity. PMID:27706051
Gas House Autonomous System Monitoring
NASA Technical Reports Server (NTRS)
Miller, Luke; Edsall, Ashley
2015-01-01
Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.
Piot, Bram; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-01-01
Objectives This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. Methods The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. Results A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. Conclusion LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets. PMID:20167732
Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-02-01
This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets.
Durrieu, Gilles; Pham, Quang-Khoai; Foltête, Anne-Sophie; Maxime, Valérie; Grama, Ion; Tilly, Véronique Le; Duval, Hélène; Tricot, Jean-Marie; Naceur, Chiraz Ben; Sire, Olivier
2016-07-01
Water quality can be evaluated using biomarkers such as tissular enzymatic activities of endemic species. Measurement of molluscs bivalves activity at high frequency (e.g., valvometry) during a long time period is another way to record the animal behavior and to evaluate perturbations of the water quality in real time. As the pollution affects the activity of oysters, we consider the valves opening and closing velocities to monitor the water quality assessment. We propose to model the huge volume of velocity data collected in the framework of valvometry using a new nonparametric extreme values statistical model. The objective is to estimate the tail probabilities and the extreme quantiles of the distribution of valve closing velocity. The tail of the distribution function of valve closing velocity is modeled by a Pareto distribution with parameter t,τ , beyond a threshold τ according to the time t of the experiment. Our modeling approach reveals the dependence between the specific activity of two enzymatic biomarkers (Glutathione-S-transferase and acetylcholinesterase) and the continuous recording of oyster valve velocity, proving the suitability of this tool for water quality assessment. Thus, valvometry allows in real-time in situ analysis of the bivalves behavior and appears as an effective early warning tool in ecological risk assessment and marine environment monitoring.
Can Technology Improve the Quality of Colonoscopy?
Thirumurthi, Selvi; Ross, William A; Raju, Gottumukkala S
2016-07-01
In order for screening colonoscopy to be an effective tool in reducing colon cancer incidence, exams must be performed in a high-quality manner. Quality metrics have been presented by gastroenterology societies and now include higher adenoma detection rate targets than in the past. In many cases, the quality of colonoscopy can often be improved with simple low-cost interventions such as improved procedure technique, implementing split-dose bowel prep, and monitoring individuals' performances. Emerging technology has expanded our field of view and image quality during colonoscopy. We will critically review several technological advances in the context of quality metrics and discuss if technology can really improve the quality of colonoscopy.
Physical health care monitoring for people with serious mental illness.
Tosh, Graeme; Clifton, Andrew; Mala, Shereen; Bachner, Mick
2010-03-17
Current guidance suggests that we should monitor the physical health of people with serious mental illness and there has been a significant financial investment over recent years to provide this. To assess the effectiveness of physical health monitoring as a means of reducing morbidity, mortality and reduction in quality of life in people with serious mental illness. We searched the Cochrane Schizophrenia Group Trials Register (October 2009) which is based on regular searches of CINAHL, EMBASE, MEDLINE and PsycINFO. All randomised or quasi-randomised clinical trials focusing on physical health monitoring versus standard care or comparing i) self monitoring vs monitoring by health care professional; ii) simple vs complex monitoring; iii) specific vs non-specific checks iv) once only vs regular checks or v) comparison of different guidance. The authors (GT, AC, SM) independently screened search results and identified three studies as possibly fulfilling the review's criteria. On examination, however, all three were subsequently excluded. We did not identify any randomised trials which assessed the effectiveness of physical health monitoring in people with serious mental illness. There is no evidence from randomised trials to support current guidance and practice. Guidance and practice are based on expert consensus, clinical experience and good intentions rather than high quality evidence.
An Architecture for Continuous Data Quality Monitoring in Medical Centers.
Endler, Gregor; Schwab, Peter K; Wahl, Andreas M; Tenschert, Johannes; Lenz, Richard
2015-01-01
In the medical domain, data quality is very important. Since requirements and data change frequently, continuous and sustainable monitoring and improvement of data quality is necessary. Working together with managers of medical centers, we developed an architecture for a data quality monitoring system. The architecture enables domain experts to adapt the system during runtime to match their specifications using a built-in rule system. It also allows arbitrarily complex analyses to be integrated into the monitoring cycle. We evaluate our architecture by matching its components to the well-known data quality methodology TDQM.
A Water Quality Monitoring Programme for Schools and Communities
ERIC Educational Resources Information Center
Spellerberg, Ian; Ward, Jonet; Smith, Fiona
2004-01-01
A water quality monitoring programme for schools is described. The purpose of the programme is to introduce school children to the concept of reporting on the "state of the environment" by raising the awareness of water quality issues and providing skills to monitor water quality. The programme is assessed and its relevance in the…
Using business intelligence to monitor clinical quality metrics.
Resetar, Ervina; Noirot, Laura A; Reichley, Richard M; Storey, Patricia; Skiles, Ann M; Traynor, Patrick; Dunagan, W Claiborne; Bailey, Thomas C
2007-10-11
BJC HealthCare (BJC) uses a number of industry standard indicators to monitor the quality of services provided by each of its hospitals. By establishing an enterprise data warehouse as a central repository of clinical quality information, BJC is able to monitor clinical quality performance in a timely manner and improve clinical outcomes.
Community drinking water quality monitoring data: utility for public health research and practice.
Jones, Rachael M; Graber, Judith M; Anderson, Robert; Rockne, Karl; Turyk, Mary; Stayner, Leslie T
2014-01-01
Environmental Public Health Tracking (EPHT) tracks the occurrence and magnitude of environmental hazards and associated adverse health effects over time. The EPHT program has formally expanded its scope to include finished drinking water quality. Our objective was to describe the features, strengths, and limitations of using finished drinking water quality data from community water systems (CWSs) for EPHT applications, focusing on atrazine and nitrogen compounds in 8 Midwestern states. Water quality data were acquired after meeting with state partners and reviewed and merged for analysis. Data and the coding of variables, particularly with respect to censored results (nondetects), were not standardized between states. Monitoring frequency varied between CWSs and between atrazine and nitrates, but this was in line with regulatory requirements. Cumulative distributions of all contaminants were not the same in all states (Peto-Prentice test P < .001). Atrazine results were highly censored in all states (76.0%-99.3%); higher concentrations were associated with increased measurement frequency and surface water as the CWS source water type. Nitrate results showed substantial state-to-state variability in censoring (20.5%-100%) and in associations between concentrations and the CWS source water type. Statistical analyses of these data are challenging due to high rates of censoring and uncertainty about the appropriateness of parametric assumptions for time-series data. Although monitoring frequency was consistent with regulations, the magnitude of time gaps coupled with uncertainty about CWS service areas may limit linkage with health outcome data.
Gardner, Karen; Davies, G Powell; Edwards, Karen; McDonald, Julie; Findlay, Terry; Kearns, Rachael; Joshi, Chandni; Harris, Mark
2016-01-01
The aim of this systematic review was to assess evidence of the impact of commissioning on health service use, quality, outcomes and value for money and to consider findings in the Australian context. Systematic searches of the literature identified 444 papers and, after exclusions, 36 were subject to full review. The commissioning cycle (planning, contracting, monitoring) formed a framework for analysis and impacts were assessed at individual, subpopulation and population levels. Little evidence of the effectiveness of commissioning at any level was available and observed impacts were highly context-dependent. There was insufficient evidence to identify a preferred model. Lack of skills and capacity were cited as major barriers to the implementation of commissioning. Successful commissioning requires a clear policy framework of national and regional priorities that define agreed targets for commissioning agencies. Engagement of consumers and providers, especially physicians, was considered to be critically important but is time consuming and has proven difficult to sustain. Adequate information on the cost, volume and quality of healthcare services is critically important for setting priorities, and for contracting and monitoring performance. Lack of information resulted in serious problems. High-quality nationally standardised performance measures and data requirements need to be built into contracts and ongoing monitoring and evaluation. In Australia, there is significant work to be done in areas of policy and governance, funding systems and incentives, patient enrolment or registration, information systems, individual and organisational capacity, community engagement and experience in commissioning.
Hampton roads regional Water-Quality Monitoring Program
Porter, Aaron J.; Jastram, John D.
2016-12-02
IntroductionHow much nitrogen, phosphorus, and suspended solids are contributed by the highly urbanized areas of the Hampton Roads region in Virginia to Chesapeake Bay? The answer to this complex question has major implications for policy decisions, resource allocations, and efforts aimed at restoring clean waters to Chesapeake Bay and its tributaries. To quantify the amount of nitrogen, phosphorus, and suspended solids delivered to the bay from this region, the U.S. Geological Survey has partnered with the Hampton Roads Sanitation District (HRSD), in cooperation with the Hampton Roads Planning District Commission (HRPDC), to conduct a water-quality monitoring program throughout the Hampton Roads region.
Low cost digester monitoring under realistic conditions: Rural use of biogas and digestate quality.
Castro, L; Escalante, H; Jaimes-Estévez, J; Díaz, L J; Vecino, K; Rojas, G; Mantilla, L
2017-09-01
The purpose of this work was to assess the behaviour of anaerobic digestion of cattle manure in a rural digester under realistic conditions, and estimate the quality and properties of the digestate. The data obtained during monitoring indicated that the digester operation was stable without risk of inhibition. It produced an average of 0.85Nm 3 biogas/d at 65.6% methane, providing an energy savings of 76%. In addition, the digestate contained high nutrient concentrations, which is an important feature of fertilizers. However, this method requires post-treatment due to the presence of pathogens. Copyright © 2017 Elsevier Ltd. All rights reserved.
Townsley, Hermaleigh; White, Bonnie; Langlotz, Tobias; Taylor, William J
2017-01-01
Background Rheumatoid arthritis (RA) is a chronic inflammatory arthritis requiring long-term treatment with regular monitoring by a rheumatologist to achieve good health outcomes. Since people with RA may wish to monitor their own disease activity with a smartphone app, it is important to understand the functions and quality of apps for this purpose. Objective The aim of our study was to assess the features and quality of apps to assist people to monitor their RA disease activity by (1) summarizing the available apps, particularly the instruments used for measurement of RA disease activity; (2) comparing the app features with American College of Rheumatology and European League against Rheumatism (ACR and EULAR) guidelines for monitoring of RA disease activity; and (3) rating app quality with the Mobile App Rating Scale (MARS). Methods Systematic searches of the New Zealand iTunes and Google Play app stores were used to identify all apps for monitoring of RA disease activity that could be used by people with RA. The apps were described by both key metadata and app functionality. App adherence with recommendations for monitoring of RA disease activity in clinical practice was evaluated by identifying whether apps included calculation of a validated composite disease activity measure and recorded results for future retrieval. App quality was assessed by 2 independent reviewers using the MARS. Results The search identified 721 apps in the Google Play store and 216 in the iTunes store, of which 19 unique apps met criteria for inclusion (8 from both app stores, 8 iTunes, and 3 Google Play). In total, 14 apps included at least one validated instrument measuring RA disease activity; 7 of 11 apps that allowed users to enter a joint count used the standard 28 swollen and tender joint count; 8 apps included at least one ACR and EULAR-recommended RA composite disease activity (CDA) measure; and 10 apps included data storage and retrieval. Only 1 app, Arthritis Power, included both an RA CDA measure and tracked data, but this app did not include the standard 28 tender and swollen joint count. The median overall MARS score for apps was 3.41/5. Of the 6 apps that scored ≥4/5 on the overall MARS rating, only 1 included a CDA score endorsed by ACR and EULAR; however, this app did not have a data tracking function. Conclusions This review found a lack of high-quality apps for longitudinal assessment of RA disease activity. Current apps fall into two categories: simple calculators primarily for rheumatologists and data tracking tools for people with RA. The latter do not uniformly collect data using validated instruments or composite disease activity measures. There is a need for appropriate, high-quality apps for use by rheumatologists and patients together in co-management of RA. PMID:28223263
Xie, Xia; Yang, Yang; Zhou, Henghui; Li, Meixian; Zhu, Zhiwei
2018-03-01
Magnetic impurities of lithium ion battery degrade both the capacity and cycling rates, even jeopardize the safety of the battery. During the material manufacture of LiFePO 4 , two opposite and extreme cases (trace impurity Fe(II) with high content of Fe(III) background in FePO 4 of initial end and trace Fe(III) with high content of Fe(II) background in LiFePO 4 of terminal end) can result in the generation of magnetic impurities. Accurate determination of impurities and precise evaluation of raw material or product are necessary to ensure reliability, efficiency and economy in lithium ion battery manufacture. Herein, two kinds of rapid, simple, and sensitive capillary electrophoresis (CE) methods are proposed for quality monitoring of initial and terminal manufacture of LiFePO 4 based lithium ion batteries. The key to success includes the smart use of three common agents 1,10-phenanthroline (phen), EDTA and cetyltrimethyl ammonium bromide (CTAB) in sample solution or background electrolyte (BGE), as well as sample stacking technique of CE feature. Owing to the combination of field-enhanced sample injection (FESI) technique with high stacking efficiency, detection limits of 2.5nM for Fe(II) and 0.1μM for Fe(III) were obtained corresponding to high content of Fe(III) and Fe(II), respectively. The good recoveries and reliability demonstrate that the developed methods are accurate approaches for quality monitoring of LiFePO 4 manufacture. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Suparno, Sudomo, Rahardjo, Boedi
2017-09-01
Experts and practitioners agree that the quality of vocational high schools needs to be greatly improved. Many construction services have voiced their dissatisfaction with today's low-quality vocational high school graduates. The low quality of graduates is closely related to the quality of the teaching and learning process, particularly teaching materials. In their efforts to improve the quality of vocational high school education, the government have implemented Curriculum 2013 (K13) and supplied teaching materials. However, the results of monitoring and evaluation done by the Directorate of Vocational High School, Directorate General of Secondary Education (2014), the provision of tasks for students in the teaching materials was totally inadequate. Therefore, to enhance the quality and the result of the instructional process, there should be provided students' worksheets that can stimulate and improve students' problem-solving skills and soft skills. In order to develop worksheets that can meet the academic requirements, the development needs to be in accordance with an innovative learning approach, which is the soft skill-based scientific approach.
Moreland, Joe A.; Wood, Wayne A.
1982-01-01
Water-level and water-quality data were collected from monitoring wells at wastewater-treatment facilities in Glacier National Park. Five additional shallow observation wells were installed at the Glacier Park Headquarters facility to monitor water quality in the shallow ground-water system.Water-level, water-quality, and geologic information indicate that some of the initial monitoring wells are not ideally located to sample ground water most likely to be affected by waste disposal at the sites. Small differences in chemical characteristics between samples from monitor wells indicate that effluent may be affecting ground-water quality but that impacts are not significant.Future monitoring of ground-water quality could be limited to selected wells most likely to be impacted by percolating effluent. Laboratory analyses for common ions could detect future impacts.
High-quality cardiopulmonary resuscitation.
Nolan, Jerry P
2014-06-01
The quality of cardiopulmonary resuscitation (CPR) impacts on outcome after cardiac arrest. This review will explore the factors that contribute to high-quality CPR and the metrics that can be used to monitor performance. A recent consensus statement from North America defined five key components of high-quality CPR: minimizing interruptions in chest compressions, providing compressions of adequate rate and depth, avoiding leaning on the chest between compressions, and avoiding excessive ventilation. Studies have shown that real-time feedback devices improve the quality of CPR and, in one before-and-after study, outcome from out-of-hospital cardiac arrest. There is evidence for increasing survival rates following out-of-hospital cardiac arrest and this is associated with increasing rates of bystander CPR. The quality of CPR provided by healthcare professionals can be improved with real-time feedback devices. The components of high-quality CPR and the metrics that can be measured and fed back to healthcare professionals have been defined by expert consensus. In the future, real-time feedback based on the physiological responses to CPR may prove more effective.
Genetic Improvement of Switchgrass and Other Herbaceous Plants for Use as Biomass Fuel Feedstock
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogel, K.P.
2001-01-11
It should be highly feasible to genetically modify the feedstock quality of switchgrass and other herbaceous plants using both conventional and molecular breeding techniques. Effectiveness of breeding to modify herbages of switchgrass and other perennial and annual herbaceous species has already been demonstrated. The use of molecular markers and transformation technology will greatly enhance the capability of breeders to modify the plant structure and cell walls of herbaceous plants. It will be necessary to monitor gene flow to remnant wild populations of plants and have strategies available to curtail gene flow if it becomes a potential problem. It also willmore » be necessary to monitor plant survival and long-term productivity as affected by genetic changes that improve forage quality. Information on the conversion processes that will be used and the biomass characteristics that affect conversion efficiency and rate is absolutely essential as well as information on the relative economic value of specific traits. Because most forage or biomass quality characteristics are highly affected by plant maturity, it is suggested that plant material of specific maturity stages be used in research to determining desirable feedstock quality characteristics. Plant material could be collected at various stages of development from an array of environments and storage conditions that could be used in conversion research. The same plant material could be used to develop NIRS calibrations that could be used by breeders in their selection programs and also to develop criteria for a feedstock quality assessment program. Breeding for improved feedstock quality will likely affect the rate of improvement of biomass production per acre. If the same level of resources are used, multi-trait breeding simply reduces the selection pressure and hence the breeding progress that can be made for a single trait unless all the traits are highly correlated. Since desirable feedstock traits are likely to be similar to IVDMD, it is likely that they will not be highly positively correlated with yield. Hence to achieve target yields and improve specific quality traits, it will likely be necessary to increase the resources available to plant breeders. Marker assisted selection will be extremely useful in breeding for quality traits, particularly for traits that can be affected by modifying a few genes. Genetic markers are going to be needed for monitoring gene flow to wild populations. Transformation will be a very useful tool for determining the affects of specific genes on biomass feedstock quality.« less
Protocol Coordinator | Center for Cancer Research
PROGRAM DESCRIPTION Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious
NASA Astrophysics Data System (ADS)
Schmidt, Sebastian; Grimmeisen, Felix; Ries, Fabian; Goldscheider, Nico; Sauter, Martin
2018-03-01
In the semi-arid eastern Mediterranean water supply is highly dependent on karst aquifers. The region is characterized by multi-year dry and wet cycles combined with high hydrological dynamics, especially during intense precipitation events. The investigated karst regions in the West Bank and Jordan are experiencing strong urbanization within the groundwater catchments and hence a rising impact on water quality. Therefore, high resolution monitoring data are required for the assessment of available water resources and the hydrogeological characterization of the karst systems. These measurements are focused on the (natural) meteorological input signals and the system output signals at the karst springs. Also soil moisture and ephemeral runoff dynamics are investigated. The monitoring data enable (1) hydrogeological characterization of the aquifers, (2) estimation of groundwater recharge via soil water balance and reservoir models, and (3) assessment of contamination dynamics in groundwater (e. g. nitrate and E. coli concentrations), allowing an optimized raw water management. Several examples illustrate the importance of high-resolution hydrological monitoring data.
,
1995-01-01
The Intergovernmental Task Force on Monitoring Water Quality (ITFM) prepared this report in collaboration with representatives of all levels of government and the private sector. The report recommends a strategy for nationwide water-quality monitoring and technical monitoring improvements to support sound water-quality decisionmaking. The strategy is intended to achieve a better return on public and private investments in monitoring, environmental protection, and natural resources management. It is also designed to expand the base of information useful to a variety of users at multiple geographic scales. Institutional and technical changes are needed to improve water-quality monitoring and to meet the full range of monitoring requirements. Monitoring must be incorporated as a critical element of program planning, implementation, and evaluation. The strategy includes recommendations in many key elements, such as the development of goal-oriented monitoring and indicators, institutional collaboration, and methods comparability. Initial actions have been taken to implement the strategy. Several Federal agencies have jointly purchased and shared remotely sensed land-cover information needed for water assessment. Major agency data systems are using common data-element names and reference tables that will ensure easy sharing of data. A number of States have held meetings with collectors of water information to initiate statewide monitoring strategies. New monitoring guidance has been developed for Federal water-quality grants to States. Many State offices have changed monitoring programs to place emphasis on priority watersheds and to improve assessment of water quality. As the competition increases for adequate supplies of clean water, concerns about public health and the environment escalate, and more demands are placed on the water information infrastructure. To meet these demands, the collaborative approach has already produced benefits, which will continue to grow as the recommendations are implemented
Sorenson, S.K.; Cascos, P.V.; Glass, R.L.
1984-01-01
A program to monitor the ground- and surface water quality in the Livermore-Amador Valley has been operated since 1976. As of 1982, this monitoring network consisted of approximately 130 wells, about 100 of which were constructed specifically for this program, and 9 surface water stations. Increased demand on the groundwater for municipal and industrial water supply in the past has caused a decline in water levels and a gradual buildup of salts from natural surface-water recharge and land disposal of treated wastewater from waste treatment plants. Results of this study identify the salt buildup to be the major problem with the groundwater quality. Established water quality objectives for dissolved solids are exceeded in 52 of 130 wells. Concentrations of dissolved nitrate are also in excess of basin objectives and health standards. Water quality in both surface and groundwater is highly variable areally. Magnesium to calcium magnesium bicarbonate groundwater are found in the areas where most of the high volume municipal wells are located. Large areas of sodium bicarbonate water occur in the northern part of the valley. Except for two stations on Arroyo Las Positas which has sodium chloride water, surface water is mixed-cation bicarbonate water. (USGS)
Improved quality monitoring of multi-center acupuncture clinical trials in China
2009-01-01
Background In 2007, the Chinese Science Division of the State Administration of Traditional Chinese Medicine(TCM) convened a special conference to discuss quality control for TCM clinical research. Control and assurance standards were established to guarantee the quality of clinical research. This paper provides practical guidelines for implementing strict and reproducible quality control for acupuncture randomized controlled trials (RCTs). Methods A standard quality control program (QCP) was established to monitor the quality of acupuncture trials. Case report forms were designed; qualified investigators, study personnel and data management personnel were trained. Monitors, who were directly appointed by the project leader, completed the quality control programs. They guaranteed data accuracy and prevented or detected protocol violations. Clinical centers and clinicians were audited, the randomization system of the centers was inspected, and the treatment processes were audited as well. In addition, the case report forms were reviewed for completeness and internal consistency, the eligibility and validity of the patients in the study was verified, and data was monitored for compliance and accuracy. Results and discussion The monitors complete their reports and submit it to quality assurance and the sponsors. Recommendations and suggestions are made for improving performance. By holding regular meetings to discuss improvements in monitoring standards, the monitors can improve quality and efficiency. Conclusions Supplementing and improving the existed guidelines for quality monitoring will ensure that large multi-centre acupuncture clinical trials will be considered as valid and scientifically stringent as pharmaceutical clinical trials. It will also develop academic excellence and further promote the international recognition of acupuncture. PMID:20035630
Fang, Wei; Ni, Zhaohui; Qian, Jiaqi
2014-01-01
The proportion of end-stage renal disease (ESRD) patients on peritoneal dialysis (PD) has increased very fast in China over the last decade. Renji Hospital, affiliated with Shanghai Jiaotong University School of Medicine, is a recognized high-quality PD unit with a high PD utilization rate, excellent patient and technique survival (1-year and 5-year patient survival rate of 93% and 71%, and 1-year and 5-year technique survival of 96% and 82%, respectively), low peritonitis rate and a well-documented good quality of life of the treated patients. We believe that a dedicated and experienced PD team, a structured patient training program, continuous patient support, establishing and utilizing standardized protocols, starting PD with low dialysis dose, monitoring key performance indicators (KPIs), and continuous quality improvement (CQI) are the key factors underlying this successful PD program. PMID:24962961
The effects of combined sewer overflow events on riverine sources of drinking water.
Madoux-Humery, Anne-Sophie; Dorner, Sarah; Sauvé, Sébastien; Aboulfadl, Khadija; Galarneau, Martine; Servais, Pierre; Prévost, Michèle
2016-04-01
This study was set out to investigate the impacts of Combined Sewer Overflows (CSOs) on the microbiological water quality of a river used as a source of drinking water treatment plants. Escherichia coli concentrations were monitored at various stations of a river segment located in the Greater Montreal Area including two Drinking Water Intakes (DWIs) in different weather conditions (dry weather and wet weather (precipitation and snowmelt period)). Long-term monitoring data (2002-2011) at DWIs revealed good microbiological water quality with E. coli median concentrations of 20 and 30 CFU/100 mL for DWI-1 and DWI-2 respectively. However, E. coli concentration peaks reached up to 510 and 1000 CFU/100 mL for both DWIs respectively. Statistical Process Control (SPC) analysis allowed the identification of E. coli concentration peaks in almost a decade of routine monitoring data at DWIs. Almost 80% of these concentrations were linked to CSO discharges caused by precipitation exceeding 10 mm or spring snowmelt. Dry weather monitoring confirmed good microbiological water quality. Wet weather monitoring showed an increase of approximately 1.5 log of E. coli concentrations at DWIs. Cumulative impacts of CSO discharges were quantified at the river center with an increase of approximately 0.5 log of E. coli concentrations. Caffeine (CAF) was tested as a potential chemical indicator of CSO discharges in the river and CAF concentrations fell within the range of previous measurements performed for surface waters in the same area (∼20 ng/L). However, no significant differences were observed between CAF concentrations in dry and wet weather, as the dilution potential of the river was too high. CSO event based monitoring demonstrated that current bi-monthly or weekly compliance monitoring at DWIs underestimate E. coli concentrations entering DWIs and thus, should not be used to quantify the risk at DWIs. High frequency event-based monitoring is a desirable approach to establish the importance and duration of E. coli peak concentrations entering DWIs. Copyright © 2016 Elsevier Ltd. All rights reserved.
Liu, Xiaohan; Zhang, Yunlin; Shi, Kun; Zhu, Guangwei; Xu, Hai; Zhu, Mengyuan
2014-12-01
The development of techniques for real-time monitoring of water quality is of great importance for effectively managing inland water resources. In this study, we first analyzed the absorption and fluorescence properties in a large subtropical reservoir and then used a chromophoric dissolved organic matter (CDOM) fluorescence monitoring sensor to predict several water quality parameters including the total nitrogen (TN), total phosphorus (TP), chemical oxygen demand (COD), dissolved organic carbon (DOC), and CDOM fluorescence parallel factor analysis (PARAFAC) components in the reservoir. The CDOM absorption coefficient at 254 nm (a(254)), the humic-like component (C1), and the tryptophan-like component (C3) decreased significantly along a gradient from the northwest to the lake center, northeast, southwest, and southeast region in the reservoir. However, no significant spatial difference was found for the tyrosine-like component (C2), which contributed only four marked peaks. A highly significant linear correlation was found between the a(254) and CDOM concentration measured using the CDOM fluorescence sensor (r(2) = 0.865, n = 76, p < 0.001), indicating that CDOM concentrations could act as a proxy for the CDOM absorption coefficient measured in the laboratory. Significant correlations were also found between the CDOM concentration and TN, TP, COD, DOC, and the maximum fluorescence intensity of C1, suggesting that the real-time monitoring of CDOM concentrations could be used to predict these water quality parameters and trace the humic-like fluorescence substance in clear aquatic ecosystems with DOC <2 mg/L and total suspended matter (TSM) concentrations <15 mg/L. These results demonstrate that the CDOM fluorescence sensor is a useful tool for on-line water quality monitoring if the empirical relationship between the CDOM concentration measured using the CDOM fluorescence sensor and the water quality parameters is calibrated and validated.
An Enhanced K-Means Algorithm for Water Quality Analysis of The Haihe River in China.
Zou, Hui; Zou, Zhihong; Wang, Xiaojing
2015-11-12
The increase and the complexity of data caused by the uncertain environment is today's reality. In order to identify water quality effectively and reliably, this paper presents a modified fast clustering algorithm for water quality analysis. The algorithm has adopted a varying weights K-means cluster algorithm to analyze water monitoring data. The varying weights scheme was the best weighting indicator selected by a modified indicator weight self-adjustment algorithm based on K-means, which is named MIWAS-K-means. The new clustering algorithm avoids the margin of the iteration not being calculated in some cases. With the fast clustering analysis, we can identify the quality of water samples. The algorithm is applied in water quality analysis of the Haihe River (China) data obtained by the monitoring network over a period of eight years (2006-2013) with four indicators at seven different sites (2078 samples). Both the theoretical and simulated results demonstrate that the algorithm is efficient and reliable for water quality analysis of the Haihe River. In addition, the algorithm can be applied to more complex data matrices with high dimensionality.
Key Performance Indicators in Radiology: You Can't Manage What You Can't Measure.
Harvey, H Benjamin; Hassanzadeh, Elmira; Aran, Shima; Rosenthal, Daniel I; Thrall, James H; Abujudeh, Hani H
2016-01-01
Quality assurance (QA) is a fundamental component of every successful radiology operation. A radiology QA program must be able to efficiently and effectively monitor and respond to quality problems. However, as radiology QA has expanded into the depths of radiology operations, the task of defining and measuring quality has become more difficult. Key performance indicators (KPIs) are highly valuable data points and measurement tools that can be used to monitor and evaluate the quality of services provided by a radiology operation. As such, KPIs empower a radiology QA program to bridge normative understandings of health care quality with on-the-ground quality management. This review introduces the importance of KPIs in health care QA, a framework for structuring KPIs, a method to identify and tailor KPIs, and strategies to analyze and communicate KPI data that would drive process improvement. Adopting a KPI-driven QA program is both good for patient care and allows a radiology operation to demonstrate measurable value to other health care stakeholders. Copyright © 2015 Mosby, Inc. All rights reserved.
An ultra-high input impedance ECG amplifier for long-term monitoring of athletes.
Gargiulo, Gaetano; Bifulco, Paolo; Cesarelli, Mario; Ruffo, Mariano; Romano, Maria; Calvo, Rafael A; Jin, Craig; van Schaik, André
2010-01-01
We present a new, low-power electrocardiogram (ECG) recording system with an ultra-high input impedance that enables the use of long-lasting, dry electrodes. The system incorporates a low-power Bluetooth module for wireless connectivity and is designed to be suitable for long-term monitoring during daily activities. The new system using dry electrodes was compared with a clinically approved ECG reference system using gelled Ag/AgCl electrodes and performance was found to be equivalent. In addition, the system was used to monitor an athlete during several physical tasks, and a good quality ECG was obtained in all cases, including when the athlete was totally submerged in fresh water.
Testing the applicability of rapid on-site enzymatic activity detection for surface water monitoring
NASA Astrophysics Data System (ADS)
Stadler, Philipp; Vogl, Wolfgang; Juri, Koschelnik; Markus, Epp; Maximilian, Lackner; Markus, Oismüller; Monika, Kumpan; Peter, Strauss; Regina, Sommer; Gabriela, Ryzinska-Paier; Farnleitner Andreas, H.; Matthias, Zessner
2015-04-01
On-site detection of enzymatic activities has been suggested as a rapid surrogate for microbiological pollution monitoring of water resources (e.g. using glucuronidases, galactosidases, esterases). Due to the possible short measuring intervals enzymatic methods have high potential as near-real time water quality monitoring tools. This presentation describes results from a long termed field test. For twelve months, two ColiMinder devices (Vienna Water Monitoring, Austria) for on-site determination of enzymatic activity were tested for stream water monitoring at the experimental catchment HOAL (Hydrological Open Air Laboratory, Center for Water Resource Systems, Vienna University of Technology). The devices were overall able to follow and reflect the diverse hydrological and microbiological conditions of the monitored stream during the test period. Continuous data in high temporal resolution captured the course of enzymatic activity in stream water during diverse rainfall events. The method also proofed sensitive enough to determine diurnal fluctuations of enzymatic activity in stream water during dry periods. The method was able to capture a seasonal trend of enzymatic activity in stream water that matches the results gained from Colilert18 analysis for E. coli and coliform bacteria of monthly grab samples. Furthermore the comparison of ColiMinder data with measurements gained at the same test site with devices using the same method but having different construction design (BACTcontrol, microLAN) showed consistent measuring results. Comparative analysis showed significant differences between measured enzymatic activity (modified fishman units and pmol/min/100ml) and cultivation based analyses (most probable number, colony forming unit). Methods of enzymatic activity measures are capable to detect ideally the enzymatic activity caused by all active target bacteria members, including VBNC (viable but nonculturable) while cultivation based methods cannot detect VBNC bacteria. Therefore the applicability of on-site enzymatic activity determination as a direct surrogate or proxy parameter for microbiological standard assays and quantification of fecal indicator bacteria (FIB) concentration could not be approved and further research in this field is necessary. Presently we conclude that rapid on-site detection of enzymatic activity is applicable for surface water monitoring and that it constitutes a complementary on-site monitoring parameter with high potential. Selection of the type of measured enzymatic activities has to be done on a catchment-specific basis and further work is needed to learn more about its detailed information characteristics in different habitats. The accomplishment of this method detecting continuous data of enzymatic activity in high temporal resolution caused by a target bacterial member is on the way of becoming a powerful tool for water quality monitoring, health related water quality- and early warning requirements.
Lin, Steve; Scales, Damon C
2016-06-28
High-quality cardiopulmonary resuscitation (CPR) has been shown to improve survival outcomes after cardiac arrest. The current standard in studies evaluating CPR quality is to measure CPR process measures-for example, chest compression rate, depth, and fraction. Published studies evaluating CPR feedback devices have yielded mixed results. Newer approaches that seek to optimize CPR by measuring physiological endpoints during the resuscitation may lead to individualized patient care and improved patient outcomes.
2005-06-01
impacts to storm water quality can range from minor to severe. For this project, impacts are anticipated to be moderate ifBMPs are adequately applied...monitored outfalls. High turbidity, suspended solids, and decreased cross section due to deposition may violate storm water quality benchmarks and...result in a Notice of Violation (NOV) for storm water quality permits. Besides erosive impacts, construction period activities can cause much more
NASA Astrophysics Data System (ADS)
Thi Van Le, Khoa; Minkman, Ellen; Nguyen Thi Phuong, Thuy; Rutten, Martine; Bastiaanssen, Wim
2016-04-01
Remote sensing and citizen science can be utilized to fulfill the gap of conventional monitoring methods. However, how to engage these techniques, principally taking advantage of local capacities and of globally accessible data for satisfying the continuous data requirements and uncertainties are exciting challenges. Previous studies in Vietnam showed that official documents regulated towards responding the vital need of upgrading national water monitoring infrastructures do not put the huge potentials of free satellite images and crowd-based data collection into account, this factor also limits publications related to these techniques. In this research, a new water monitoring approach will be developed friendly with areas suffering poor quality monitoring works. Particularly, algorithms respecting to the relationship between temperature, total suspended sediment (TSS), chlorophyll and information collected by sensors onboard Landsat-8 and Sentinel-2 MSI satellites are built in the study area in Northern Vietnam; additionally, undergraduate student volunteers were sent to the sites with all the measurement activities are designed to coincide with the time when the study area captured by the satellites to compare the results. While conventional techniques are proving their irreplaceable role in the water monitoring network, the utilization of remote sensing techniques and citizen science in this study will demonstrate highly supportive values, saving monitoring costs and time; advantaging local human resources to science; providing an inclusive assessment of water quality changes along with land-use change in the study area, these approaches are excellent alternatives to meet the demand of real-time, continuous data nationwide.
NASA Astrophysics Data System (ADS)
Englert, Jennifer; Claude, Anja; Kubistin, Dagmar; Tensing, Erasmus; Michl, Katja; Plass-Duelmer, Christian
2017-04-01
Atmospheric chemistry and composition are influenced by volatile organic compounds (VOCs) emitted from natural and anthropogenic sources. Due to their toxicity and their crucial role in ozone and aerosol formation VOCs impact air quality and climate change and high quality observations are demanded. The European Metrology Research Programme (EMRP) project KEY-VOCs has targeted the improvement of VOC measurement capabilities with the focus on VOCs relevant for indoor air as well as for air quality and climate monitoring programmes. One major uncertainty is the influence of surface effects of the measurement devices. By developing a test system the adsorption/desorption effects of certain VOCs can be systematically examined. Different tubing materials e.g. stainless steel and PFA were analysed with the oxygenated VOC methanol and results of these experiments will be presented. In air quality monitoring very low levels of VOCs have to be measured. Purified air or nitrogen is widely used as a zero gas to characterize measurement systems and procedures as well as for instrument calibration. A high quality zero gas is an important contributor to the quality of the measurements and generally achieved by using state-of-the-art purification technologies. The efficiency of several air purifiers was assessed and the results have been analysed.
Water Quality Assessment of Ayeyarwady River in Myanmar
NASA Astrophysics Data System (ADS)
Thatoe Nwe Win, Thanda; Bogaard, Thom; van de Giesen, Nick
2015-04-01
Myanmar's socio-economic activities, urbanisation, industrial operations and agricultural production have increased rapidly in recent years. With the increase of socio-economic development and climate change impacts, there is an increasing threat on quantity and quality of water resources. In Myanmar, some of the drinking water coverage still comes from unimproved sources including rivers. The Ayeyarwady River is the main river in Myanmar draining most of the country's area. The use of chemical fertilizer in the agriculture, the mining activities in the catchment area, wastewater effluents from the industries and communities and other development activities generate pollutants of different nature. Therefore water quality monitoring is of utmost importance. In Myanmar, there are many government organizations linked to water quality management. Each water organization monitors water quality for their own purposes. The monitoring is haphazard, short term and based on individual interest and the available equipment. The monitoring is not properly coordinated and a quality assurance programme is not incorporated in most of the work. As a result, comprehensive data on the water quality of rivers in Myanmar is not available. To provide basic information, action is needed at all management levels. The need for comprehensive and accurate assessments of trends in water quality has been recognized. For such an assessment, reliable monitoring data are essential. The objective of our work is to set-up a multi-objective surface water quality monitoring programme. The need for a scientifically designed network to monitor the Ayeyarwady river water quality is obvious as only limited and scattered data on water quality is available. However, the set-up should also take into account the current socio-economic situation and should be flexible to adjust after first years of monitoring. Additionally, a state-of-the-art baseline river water quality sampling program is required which will take place during the low water season of March, 2015. The water quality information available for the Ayeyarwady as well as the baseline sampling of March 2015 will be presented. Furthermore, the specific scientific ideas but also organisational challenges for the future surface water quality monitoring network of the Ayeyarwady will be discussed.
Importance of a Priori Vertical Ozone Profiles for TEMPO Air Quality Retrievals
NASA Technical Reports Server (NTRS)
Johnson, Matthew S.; Sullivan, John; Liu, Xiong; Zoogman, Peter; Newchurch, Mike; Kuang, Shi; McGee, Thomas; Leblanc, Thierry
2017-01-01
Ozone (O3) is a toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address the limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product. TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME (Global Ozone Monitoring Experiment), GOME-2, and OMI (Ozone Monitoring Instrument). This algorithm is suggested to use a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB-Clim) O3 climatology). This study evaluates the TB-Clim dataset and model simulated O3 profiles, which could potentially serve as a priori O3 profile information in TEMPO retrievals, from near-real-time data assimilation model products (NASA GMAO's (Global Modeling and Assimilation Office) operational GEOS-5 (Goddard Earth Observing System, Version 5) FP (Forecast Products) model and reanalysis data from MERRA2 (Modern-Era Retrospective analysis for Research and Applications, Version 2)) and a full chemical transport model (CTM), GEOS-Chem. In this study, vertical profile products are evaluated with surface (0-2 kilometers) and tropospheric (0-10 kilometers) TOLNet (Tropospheric Ozone Lidar Network) observations and the theoretical impact of individual a priori profile sources on the accuracy of TEMPO O3 retrievals in the troposphere and at the surface are presented. Results indicate that while the TB-Clim climatological dataset can replicate seasonally-averaged tropospheric O3 profiles, model-simulated profiles from a full CTM resulted in more accurate tropospheric and surface-level O3 retrievals from TEMPO when compared to hourly and daily-averaged TOLNet observations. Furthermore, it is shown that when large surface O3 mixing ratios are observed, TEMPO retrieval values at the surface are most accurate when applying CTM a priori profile information compared to all other data products.
ERIC Educational Resources Information Center
Council of Chief State School Officers, Washington, DC.
The lack of high quality data to describe and monitor U.S. educational systems hampers reform decisions and will impair reform evaluation. This paper sets forth the Council of Chief State School Officers' (CCSSO) recommendations for the Council and federal, state, and local education agencies to help improve the quality of educational indicators.…
Sarah Jovan
2008-01-01
Lichens are highly valued ecological indicators known for their sensitivity to a wide variety of environmental stressors like air quality and climate change. This report summarizes baseline results from the U.S. Department of Agriculture, Forest Service, Forest Inventory and Analysis (FIA) Lichen Community Indicator covering the first full cycle of data collection (...
Analysis and quality control of carbohydrates in therapeutic proteins with fluorescence HPLC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Kun; Huang, Jian; Center for Informational Biology, University of Electronic Science and Technology of China, Chengdu 610054
Conbercept is an Fc fusion protein with very complicated carbohydrate profiles which must be carefully monitored through manufacturing process. Here, we introduce an optimized fluorescence derivatization high-performance liquid chromatographic method for glycan mapping in conbercept. Compared with conventional glycan analysis method, this method has much better resolution and higher reproducibility making it excellent for product quality control.
SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, S; Mehta, V
Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoringmore » function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.« less
Real-time water quality monitoring and providing water quality ...
EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Bay. The Village Blue demonstration project complements work that a number of state and local organizations are doing to make Baltimore Harbor “swimmable and fishable” 2 by 2020. Village Blue is designed to build upon EPA’s “Village Green” project which provides real-time air quality information to communities in six locations across the country. The presentation, “Real-time water quality monitoring and providing water quality information to the Baltimore Community”, summarizes the Village Blue real-time water quality monitoring project being developed for the Baltimore Harbor.
Fernandez, Mario
1983-01-01
Solid waste is defined along with various methods of disposal and the hydrogeologic factors to be considered when locating land-fills is presented. Types of solid waste, composition, and sources are identified. Generation of municipal solid waste in Florida has been estimated at 4.5 pounds per day per person or about 7.8 million tons per year. Leachate is generated when precipitation and ground water percolate through the waste. Gases, mainly carbon dioxide and methane, are also produced. Leachate generally contains high concentrations of dissolved organic and inorganic matter. The two typical hydrogeologic conditions in west-central Florida are (1) permeable sand overlying clay and limestone and (2) permeable sand overlying limestone. These conditions are discussed in relation to leachate migration. Factors in landfill site selection are presented and discussed, followed by a discussion on monitoring landfills. Monitoring of landfills includes the drilling of test holes, measuring physical properties of the corings, installation of monitoring wells, and water-quality monitoring. (USGS)
McBain, Lynn; Kyle, Anna
2018-03-09
To assess annual renal function monitoring and clinical indications for use in patients prescribed dabigatran. A quality improvement activity included all patients in the Compass Health Primary Health Organisation (PHO) prescribed dabigatran. Information recorded: demographics; indication for use; daily dose; height; weight; serum creatinine; and estimated glomerular filtration rate (eGFR). The first audit occurred during July 2013 - May 2014, the second during May 2014 - October 2016. Across the PHO, all patients prescribed dabigatran were reviewed: 941 patients and 1,564 respectively. At the time of the second pass audit, renal function monitoring improved from 88% to 90%, and 96% were prescribed dabigatran for an approved indication. Results showed a continuing high level of renal function monitoring across the PHO in 90% of patients prescribed dabigatran. Practitioners were reminded to use creatinine clearance as a marker of renal function. Dabigatran was prescribed for an approved indication in 96% of patients. Our results are in line with recommended best practice and clinical guidelines.
Effects of Urbanization on Stream Water Quality in the City of Atlanta, Georgia, USA
NASA Astrophysics Data System (ADS)
Peters, N. E.
2009-05-01
A long-term stream water-quality monitoring network was established in the City of Atlanta (COA) during 2003 to assess baseline water-quality conditions and the effects of urbanization on stream water quality. Routine hydrologically-based manual stream sampling, including several concurrent manual point and equal width increment sampling, was conducted approximately 12 times per year at 21 stations, with drainage areas ranging from 3.7 to 232 km2. Eleven of the stations are real-time (RT) water-quality stations having continuous measures of stream stage/discharge, pH, dissolved oxygen, specific conductance, water temperature, and turbidity, and automatic samplers for stormwater collection. Samples were analyzed for field parameters, and a broad suite of water-quality and sediment-related constituents. This paper summarizes an evaluation of field parameters and concentrations of major ions, minor and trace metals, nutrient species (nitrogen and phosphorus), and coliform bacteria among stations and with respect to watershed characteristics and plausible sources from 2003 through September 2007. The concentrations of most constituents in the COA streams are statistically higher than those of two nearby reference streams. Concentrations are statistically different among stations for several constituents, despite high variability both within and among stations. The combination of routine manual sampling, automatic sampling during stormflows, and real-time water-quality monitoring provided sufficient information about the variability of urban stream water quality to develop hypotheses for causes of water-quality differences among COA streams. Fecal coliform bacteria concentrations of most individual samples at each station exceeded Georgia's water-quality standard for any water-usage class. High chloride concentrations occur at three stations and are hypothesized to be associated with discharges of chlorinated combined sewer overflows, drainage of swimming pool(s), and dissolution and transport during rainstorms of CaCl2, a deicing salt applied to roads during winter storms. Water quality of one stream was highly affected by the dissolution and transport of ammonium alum [NH4Al(SO4)2] from an alum manufacturing plant in the watershed; streamwater has low pH (<5), low alkalinity and high concentrations of minor and trace metals. Several trace metals (Cu, Pb and Zn) exceed acute and chronic water-quality standards and the high concentrations are attributed to washoff from impervious surfaces.
Region 7 States Air Quality Monitoring Plans - Iowa
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Region 7 States Air Quality Monitoring Plans - Missouri
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Region 7 States Air Quality Monitoring Plans - Nebraska
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Region 7 States Air Quality Monitoring Plans - Kansas
National Ambient Air Quality Standard (NAAQS) - Iowa, Kansas, Missouri, and Nebraska; Annual Monitoring Network Plans, Five-Year Monitoring Network Assessments, and approval documentation. Each year, states are required to submit an annual monitoring netwo
Podevin, Michael; Fotidis, Ioannis A; Angelidaki, Irini
2018-08-01
Microalgae are well known for their ability to accumulate lipids intracellularly, which can be used for biofuels and mitigate CO 2 emissions. However, due to economic challenges, microalgae bioprocesses have maneuvered towards the simultaneous production of food, feed, fuel, and various high-value chemicals in a biorefinery concept. On-line and in-line monitoring of macromolecules such as lipids, proteins, carbohydrates, and high-value pigments will be more critical to maintain product quality and consistency for downstream processing in a biorefinery to maintain and valorize these markets. The main contribution of this review is to present current and prospective advances of on-line and in-line process analytical technology (PAT), with high-selectivity - the capability of monitoring several analytes simultaneously - in the interest of improving product quality, productivity, and process automation of a microalgal biorefinery. The high-selectivity PAT under consideration are mid-infrared (MIR), near-infrared (NIR), and Raman vibrational spectroscopies. The current review contains a critical assessment of these technologies in the context of recent advances in software and hardware in order to move microalgae production towards process automation through multivariate process control (MVPC) and software sensors trained on "big data". The paper will also include a comprehensive overview of off-line implementations of vibrational spectroscopy in microalgal research as it pertains to spectral interpretation and process automation to aid and motivate development.
Profile parameters of wheelset detection for high speed freight train
NASA Astrophysics Data System (ADS)
Yang, Kai; Ma, Li; Gao, Xiaorong; Wang, Li
2012-04-01
Because of freight train, in China, transports goods on railway freight line throughout the country, it does not depart from or return to engine shed during a long phase, thus we cannot monitor the quality of wheel set effectively. This paper provides a system which uses leaser and high speed camera, applies no-contact light section technology to get precise wheel set profile parameters. The paper employs clamping-track method to avoid complex railway ballast modification project. And detailed descript an improved image-tracking algorithm to extract central line from profile curve. For getting one pixel width and continuous line of the profile curve, uses local gray maximum points as direction control points to direct tracking direction. The results based on practical experiment show the system adapted to detection environment of high speed and high vibration, and it can effectively detect the wheelset geometric parameters with high accuracy. The system fills the gaps in wheel set detection for freight train in main line and has an enlightening function on monitoring the quality of wheel set.
Hofman, Jelle; Samson, Roeland
2014-09-01
Biomagnetic monitoring of tree leaf deposited particles has proven to be a good indicator of the ambient particulate concentration. The objective of this study is to apply this method to validate a local-scale air quality model (ENVI-met), using 96 tree crown sampling locations in a typical urban street canyon. To the best of our knowledge, the application of biomagnetic monitoring for the validation of pollutant dispersion modeling is hereby presented for the first time. Quantitative ENVI-met validation showed significant correlations between modeled and measured results throughout the entire in-leaf period. ENVI-met performed much better at the first half of the street canyon close to the ring road (r=0.58-0.79, RMSE=44-49%), compared to second part (r=0.58-0.64, RMSE=74-102%). The spatial model behavior was evaluated by testing effects of height, azimuthal position, tree position and distance from the main pollution source on the obtained model results and magnetic measurements. Our results demonstrate that biomagnetic monitoring seems to be a valuable method to evaluate the performance of air quality models. Due to the high spatial and temporal resolution of this technique, biomagnetic monitoring can be applied anywhere in the city (where urban green is present) to evaluate model performance at different spatial scales. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yousefi, Nariman; Tufenkji, Nathalie
2016-12-01
There is increasing interest in using quartz crystal microbalance with dissipation monitoring (QCM-D) to investigate the interaction of nanoparticles (NPs) with model surfaces. The high sensitivity, ease of use and the ability to monitor interactions in real-time has made it a popular technique for colloid chemists, biologists, bioengineers and biophysicists. QCM-D has been recently used to probe the interaction of NPs with supported lipid bilayers (SLBs) as model cell membranes. The interaction of NPs with SLBs is highly influenced by the quality of the lipid bilayers. Unlike many surface sensitive techniques, using QCM-D, the quality of SLBs can be assessed in real-time, hence QCM-D studies on SLB-NP interactions are less prone to the artefacts arising from bilayers that are not well formed. The ease of use and commercial availability of a wide range of sensor surfaces also have made QCM-D a versatile tool for studying NP interactions with lipid bilayers. In this review, we summarize the state-of-the-art on QCM-D based techniques for probing the interactions of NPs with lipid bilayers.
Manufacturing/Cell Therapy Specialist | Center for Cancer Research
Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID),
Patient Care Coordinator | Center for Cancer Research
PROGRAM DESCRIPTION Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious
Adaptive Decomposition of Highly Resolved Time Series into Local and Non‐local Components
Highly time-resolved air monitoring data are widely being collected over long time horizons in order to characterizeambient and near-source air quality trends. In many applications, it is desirable to split the time-resolved data into two ormore components (e.g., local and region...
Shi, Yuan; Lau, Kevin Ka-Lun; Ng, Edward
2017-08-01
Urban air quality serves as an important function of the quality of urban life. Land use regression (LUR) modelling of air quality is essential for conducting health impacts assessment but more challenging in mountainous high-density urban scenario due to the complexities of the urban environment. In this study, a total of 21 LUR models are developed for seven kinds of air pollutants (gaseous air pollutants CO, NO 2 , NO x , O 3 , SO 2 and particulate air pollutants PM 2.5 , PM 10 ) with reference to three different time periods (summertime, wintertime and annual average of 5-year long-term hourly monitoring data from local air quality monitoring network) in Hong Kong. Under the mountainous high-density urban scenario, we improved the traditional LUR modelling method by incorporating wind availability information into LUR modelling based on surface geomorphometrical analysis. As a result, 269 independent variables were examined to develop the LUR models by using the "ADDRESS" independent variable selection method and stepwise multiple linear regression (MLR). Cross validation has been performed for each resultant model. The results show that wind-related variables are included in most of the resultant models as statistically significant independent variables. Compared with the traditional method, a maximum increase of 20% was achieved in the prediction performance of annual averaged NO 2 concentration level by incorporating wind-related variables into LUR model development. Copyright © 2017 Elsevier Inc. All rights reserved.
Technology Transfer Opportunities: Automated Ground-Water Monitoring, A Proven Technology
Smith, Kirk P.; Granato, Gregory E.
1998-01-01
Introduction The U.S. Geological Survey (USGS) has developed and tested an automated ground-water monitoring system that measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automated ground-water monitoring systems can be used to monitor known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, to serve as early warning systems monitoring ground-water quality near public water-supply wells, and for ground-water quality research.
40 CFR 75.21 - Quality assurance and quality control requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
40 CFR 52.995 - Enhanced ambient air quality monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Enhanced ambient air quality monitoring. 52.995 Section 52.995 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... air quality monitoring. (a) The Governor of the State of Louisiana submitted the photochemical...
Automated monitoring of recovered water quality
NASA Technical Reports Server (NTRS)
Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.
1974-01-01
Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.
Updating the Synchrotron Radiation Monitor at TLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuo, C. H.; Hsu, S. Y.; Wang, C. J.
2007-01-19
The synchrotron radiation monitor provides useful information to support routine operation and physics experiments using the beam. Precisely knowing the profile of the beam helps to improve machine performance. The synchrotron radiation monitor at the Taiwan Light Source (TLS) was recently upgraded. The optics and modeling were improved to increase the accuracy of measurement in the small beam size. A high-performance IEEE-1394 digital CCD camera was used to improve the quality of images and extend the dynamic range of measurement. The image analysis is also improved. This report summarizes status and results.
Monitoring the sensory quality of canned white asparagus through cluster analysis.
Arana, Inés; Ibañez, Francisco C; Torre, Paloma
2016-05-01
White asparagus is one of the 30 vegetables most consumed in the world. This paper unifies the stages of their sensory quality control. The aims of this work were to describe the sensory properties of canned white asparagus and their quality control and to evaluate the applicability of agglomerative hierarchical clustering (AHC) for classifying and monitoring the sensory quality of manufacturers. Sixteen sensory descriptors and their evaluation technique were defined. The sensory profile of canned white asparagus was high flavor characteristic, little acidity and bitterness, medium firmness and very light fibrosity, among other characteristics. The dendrogram established groups of manufacturers that had similar scores in the same set of descriptors, and each cluster grouped the manufacturers that had a similar quality profile. The sensory profile of canned white asparagus was clearly defined through the intensity evaluation of 16 descriptors, and the sensory quality report provided to the manufacturers is in detail and of easy interpretation. AHC grouped the manufacturers according to the highest quality scores in certain descriptors and is a useful tool because it is very visual. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
A method to monitor the quality of ultra-thin nitride for trench DRAM with a buried strap structure
NASA Astrophysics Data System (ADS)
Wu, Yung-Hsien; Wang, Chun-Yao; Chang, Ian; Kao, Chien-Kang; Kuo, Chia-Ming; Ku, Alex
2007-02-01
A new approach to monitor the quality of an ultra-thin nitride film has been proposed. The nitride quality is monitored by observing the oxide thickness for the nitride film after wet oxidation since the resistance to oxidation strongly depends on its quality. To obtain a stable oxide thickness without interference from extrinsic factors for process monitoring, monitor wafers without dilute HF solution clean are suggested because the native-oxide containing surface is less sensitive to oxygen and therefore forms the nitride film with stable quality. In addition, the correlation between variable retention time (VRT) performance of a real dynamic random access memory (DRAM) product and oxide thickness from different nitride process temperatures can be successfully explained and this correlation can also be used to establish the appropriate oxide thickness range for process monitoring.
A Two-Year Water Quality Monitoring Curriculum.
ERIC Educational Resources Information Center
Glazer, Richard B.; And Others
The Environmental Protection Agency developed this curriculum to train technicians to monitor water quality. Graduates of the program should be able to monitor municipal, industrial, and commercial discharges; test drinking water for purity; and determine quality of aquatic environments. The program includes algebra, communication skills, biology,…
40 CFR 63.11890 - What are my additional general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... malfunctions and required monitoring system quality assurance or quality control activities (including, as... malfunctions, or required monitoring system quality assurance or control activities in calculations used to... source, including associated air pollution control components and monitoring system components, in a...
Kim, Seokkyun; Song, Jinsu; Park, Seungkyu; Ham, Sunyoung; Paek, Kyungyeol; Kang, Minjung; Chae, Yunjung; Seo, Heewon; Kim, Hyung-Chan; Flores, Michael
A biosimilar product needs to demonstrate biosimilarity to the originator reference product, and the quality profile of the latter should be monitored throughout the period of the biosimilar's development to match the quality attributes of the 2 products that relate to efficacy and safety. For the development of a biosimilar version of trastuzumab, the reference product, Herceptin®, was extensively characterized for the main physicochemical and biologic properties by standard or state-of-the-art analytical methods, using multiple lots expiring between March 2015 and December 2019. For lots with expiry dates up to July 2018, a high degree of consistency was observed for all the tested properties. However, among the lots expiring in August 2018 or later, a downward drift was observed in %afucose (G0+G1+G2). Furthermore, the upward drift of %high mannose (M5+M6) was observed in the lots with expiry dates from June 2019 to December 2019. As a result, the combination of %afucose and %high mannose showed 2 marked drifts in the lots with expiry dates from August 2018 to December 2019, which was supported by the similar trend of biologic data, such as FcγRIIIa binding and antibody-dependent cell-mediated cytotoxicity (ADCC) activity. Considering that ADCC is one of the clinically relevant mechanisms of action for trastuzumab, the levels of %afucose and %high mannose should be tightly monitored as critical quality attributes for biosimilar development of trastuzumab.
Kim, Seokkyun; Song, Jinsu; Park, Seungkyu; Ham, Sunyoung; Paek, Kyungyeol; Kang, Minjung; Chae, Yunjung; Seo, Heewon; Kim, Hyung-Chan; Flores, Michael
2017-01-01
ABSTRACT A biosimilar product needs to demonstrate biosimilarity to the originator reference product, and the quality profile of the latter should be monitored throughout the period of the biosimilar's development to match the quality attributes of the 2 products that relate to efficacy and safety. For the development of a biosimilar version of trastuzumab, the reference product, Herceptin®, was extensively characterized for the main physicochemical and biologic properties by standard or state-of-the-art analytical methods, using multiple lots expiring between March 2015 and December 2019. For lots with expiry dates up to July 2018, a high degree of consistency was observed for all the tested properties. However, among the lots expiring in August 2018 or later, a downward drift was observed in %afucose (G0+G1+G2). Furthermore, the upward drift of %high mannose (M5+M6) was observed in the lots with expiry dates from June 2019 to December 2019. As a result, the combination of %afucose and %high mannose showed 2 marked drifts in the lots with expiry dates from August 2018 to December 2019, which was supported by the similar trend of biologic data, such as FcγRIIIa binding and antibody-dependent cell-mediated cytotoxicity (ADCC) activity. Considering that ADCC is one of the clinically relevant mechanisms of action for trastuzumab, the levels of %afucose and %high mannose should be tightly monitored as critical quality attributes for biosimilar development of trastuzumab. PMID:28296619
Methods to achieve high interrater reliability in data collection from primary care medical records.
Liddy, Clare; Wiens, Miriam; Hogg, William
2011-01-01
We assessed interrater reliability (IRR) of chart abstractors within a randomized trial of cardiovascular care in primary care. We report our findings, and outline issues and provide recommendations related to determining sample size, frequency of verification, and minimum thresholds for 2 measures of IRR: the κ statistic and percent agreement. We designed a data quality monitoring procedure having 4 parts: use of standardized protocols and forms, extensive training, continuous monitoring of IRR, and a quality improvement feedback mechanism. Four abstractors checked a 5% sample of charts at 3 time points for a predefined set of indicators of the quality of care. We set our quality threshold for IRR at a κ of 0.75, a percent agreement of 95%, or both. Abstractors reabstracted a sample of charts in 16 of 27 primary care practices, checking a total of 132 charts with 38 indicators per chart. The overall κ across all items was 0.91 (95% confidence interval, 0.90-0.92) and the overall percent agreement was 94.3%, signifying excellent agreement between abstractors. We gave feedback to the abstractors to highlight items that had a κ of less than 0.70 or a percent agreement less than 95%. No practice had to have its charts abstracted again because of poor quality. A 5% sampling of charts for quality control using IRR analysis yielded κ and agreement levels that met or exceeded our quality thresholds. Using 3 time points during the chart audit phase allows for early quality control as well as ongoing quality monitoring. Our results can be used as a guide and benchmark for other medical chart review studies in primary care.
Kraus, Tamara E.C.; Bergamaschi, Brian A.; Downing, Bryan D.
2017-07-11
Executive SummaryThis report is the first in a series of three reports that provide information about high-frequency (HF) nutrient and biogeochemical monitoring in the Sacramento–San Joaquin Delta of northern California (Delta). This first report provides an introduction to the reasons for and fundamental concepts behind collecting HF measurements, and describes the benefits associated with a real-time, continuous, HF, multi-parameter water quality monitoring station network that is co-located with flow stations. It then provides examples of how HF nutrient measurements have improved our understating of nutrient sources and cycling in aquatic systems worldwide, followed by specific examples from the Delta. These examples describe the ways in which HF instrumentation may be used for both fixed-station and spatial assessments. The overall intent of this document is to describe how HF measurements currently (2017) are being used in the Delta to examine the relationship between nutrient concentrations, nutrient cycling, and aquatic habitat conditions.The second report in the series (Downing and others, 2017) summarizes information about HF nutrient and associated biogeochemical monitoring in the northern Delta. The report synthesizes data available from the nutrient and water quality monitoring network currently operated by the U.S. Geological Survey in this ecologically important region of the Delta. In the report, we present and discuss the available data at various timescales—first, at the monthly, seasonal, and inter-annual timescales; and, second, for comparison, at the tidal and event (for example, storms, reservoir releases, phytoplankton blooms) timescales. As expected, we determined that there is substantial variability in nitrate concentrations at short timescales within hours, but also significant variability at longer timescales such as months or years. This multi-scale, high variability affects calculation of fluxes and loads, indicating that HF monitoring is necessary for understanding and assessing flux-based processes and outcomes in tidal environments, such as the Delta.The third report in the series (Bergamaschi and others, 2017) provides information about how to design HF nutrient and biogeochemical monitoring for assessment of nutrient inputs and dynamics in the Delta. The report provides background, principles, and considerations for designing an HF nutrient-monitoring network for the Sacramento–San Joaquin Delta to address high-priority, nutrient-management questions. The report starts with high-priority management questions to be addressed, continues with questions and considerations that place demands and constraints on network design, discusses the principles applicable to network design, and concludes with the presentation of three example nutrient‑monitoring network designs for the Delta. For the three example networks, we assess how they would address high-priority questions identified by the Delta Regional Monitoring Program (Delta Regional Monitoring Program Technical Advisory Committee, 2015).
Integrated approach to monitor water dynamics with drones
NASA Astrophysics Data System (ADS)
Raymaekers, Dries; De Keukelaere, Liesbeth; Knaeps, Els; Strackx, Gert; Decrop, Boudewijn; Bollen, Mark
2017-04-01
Remote sensing has been used for more than 20 years to estimate water quality in the open ocean and study the evolution of vegetation on land. More recently big improvements have been made to extend these practices to coastal and inland waters, opening new monitoring opportunities, eg. monitoring the impact of dredging activities on the aquatic environment. While satellite sensors can provide complete coverage and historical information of the study area, they are limited in their temporal revisit time and spatial resolution. Therefore, deployment of drones can create an added value and in combination with satellite information increase insights in the dynamics and actors of coastal and aquatic systems. Drones have the advantages of monitoring at high spatial detail (cm scale), with high frequency and are flexible. One of the important water quality parameters is the suspended sediment concentration. However, retrieving sediment concentrations from unmanned systems is a challenging task. The sediment dynamics in the port of Breskens, the Netherlands, were investigated by combining information retrieved from different data sources: satellite, drone and in-situ data were collected, analysed and inserted in sediment models. As such, historical (satellite), near-real time (drone) and predictive (sediment models) information, integrated in a spatial data infrastructure, allow to perform data analysis and can support decision makers.
Lejzerowicz, Franck; Esling, Philippe; Pillet, Loïc; Wilding, Thomas A.; Black, Kenneth D.; Pawlowski, Jan
2015-01-01
Environmental diversity surveys are crucial for the bioassessment of anthropogenic impacts on marine ecosystems. Traditional benthic monitoring relying on morphotaxonomic inventories of macrofaunal communities is expensive, time-consuming and expertise-demanding. High-throughput sequencing of environmental DNA barcodes (metabarcoding) offers an alternative to describe biological communities. However, whether the metabarcoding approach meets the quality standards of benthic monitoring remains to be tested. Here, we compared morphological and eDNA/RNA-based inventories of metazoans from samples collected at 10 stations around a fish farm in Scotland, including near-cage and distant zones. For each of 5 replicate samples per station, we sequenced the V4 region of the 18S rRNA gene using the Illumina technology. After filtering, we obtained 841,766 metazoan sequences clustered in 163 Operational Taxonomic Units (OTUs). We assigned the OTUs by combining local BLAST searches with phylogenetic analyses. We calculated two commonly used indices: the Infaunal Trophic Index and the AZTI Marine Biotic Index. We found that the molecular data faithfully reflect the morphology-based indices and provides an equivalent assessment of the impact associated with fish farms activities. We advocate that future benthic monitoring should integrate metabarcoding as a rapid and accurate tool for the evaluation of the quality of marine benthic ecosystems. PMID:26355099
Reconnaissance of water quality at four swine farms in Jackson County, Florida, 1993
Collins, J.J.
1996-01-01
The quality of ground water on four typical swine farms in Jackson County, Florida, was studied by analyzing water samples from wastewater lagoons, monitoring wells, and supply wells. Water samples were collected quarterly for 1 year and analyzed for the following dissolved species: nitrate, nitrite, ammonium nitrogen, phosphorus, potassium, sulfate, chloride, calcium, magnesium, fluoride, total ammonium plus organic nitrogen, total phosphorus, alkalinity, carbonate, and bicarbonate. Additionally, the following field constituents were determined in the water samples: temperature, specific conductance, pH, dissolved oxygen, and fecal streptococcus and fecal coliform bacteria. Chemical changes in swine waste as it leaches and migrates through the saturated zone were examined by comparing median values and ranges of water- quality data from farm wastewater in lagoons, shallow pond, shallow monitoring wells, and deeper farm supply wells. The effects of hydrogeologic settings and swine farmland uses on shallow ground-water quality were examined by comparing the shallow ground-water-quality data set with the results of the chemical analyses of water from the Upper Floridan aquifer, and to land uses adjacent to the monitoring wells. Substantial differences occur between the quality of diluted swine waste in the wastewater lagoons, and that of the water quality found in the shallow pond, and the ground water frm all but two of the monitoring wells of the four swine farms. The liquid from the wastewater lagoons and ground water from two wells adjacent to and down the regional gradient from a lagoon on one site, have relatively high values for the following properties and constituents: specific conductance, dissolved ammonia nitrogen, dissolved potassium, and dissolved chloride. Ground water from all other monitoring wells and farm supply wells and the surface water pond, have relatively much lower values for the same properties and constituents. To determine the relation between land uses and ground-water quality on the four swine farms, ground-water-quality data were divided according to the following land uses: confined operations in which swine are kept in houses and not allowed to roam freely, and unconfined operations in which swine are allowed to roam freely in determined areas. Confined operations had lagoons to receive the diluted swine wastes washed from the houses.
HomeADL for adaptive ADL monitoring within smart homes.
Hong, Xin; Nugent, Chris D; Finlay, Dewar D; Mulvenna, Maurice
2008-01-01
In this paper we present homeADL: a representation standard for an inference hierarchy of activities of daily living which may be monitored in a sensor equipped smart home. The approach allows a free exchange of ADL monitoring structures between different communities who share the same concern of providing high quality healthcare to the elderly. Its ability of matching different ADL protocols enables a mapping between an ADL protocol to a suitable smart home which makes an effective management of smart homes within a community hence, not only being able to satisfy an individual's healthcare requirements but also efficiently using monitoring resources at hand.
Canadian ENGOs in governance of water resources: information needs and monitoring practices.
Kebo, Sasha; Bunch, Martin J
2013-11-01
Water quality monitoring involves a complex set of steps and a variety of approaches. Its goals include understanding of aquatic habitats, informing management and facilitating decision making, and educating citizens. Environmental nongovernmental organizations (ENGOs) are increasingly engaged in water quality monitoring and act as environmental watchdogs and stewards of water resources. These organizations exhibit different monitoring mandates. As government involvement in water quality monitoring continues to decline, it becomes essential that we understand their modi operandi. By doing so, we can enhance efficacy and encourage data sharing and communication. This research examined Canadian ENGOs that collect their own data on water quality with respect to water quality monitoring activities and information needs. This work had a twofold purpose: (1) to enhance knowledge about the Canadian ENGOs operating in the realm of water quality monitoring and (2) to guide and inform development of web-based geographic information systems (GIS) to support water quality monitoring, particularly using benthic macroinvertebrate protocols. A structured telephone survey was administered across 10 Canadian provinces to 21 ENGOs that undertake water quality monitoring. This generated information about barriers and challenges of data sharing, commonly collected metrics, human resources, and perceptions of volunteer-collected data. Results are presented on an aggregate level and among different groups of respondents. Use of geomatics technology was not consistent among respondents, and we found no noteworthy differences between organizations that did and did not use GIS tools. About one third of respondents did not employ computerized systems (including databases and spreadsheets) to support data management, analysis, and sharing. Despite their advantage as a holistic water quality indicator, benthic macroinvertebrates (BMIs) were not widely employed in stream monitoring. Although BMIs are particularly suitable for the purpose of citizen education, few organizations collected this metric, despite having public education and awareness as part of their mandate.
Assessing background ground water chemistry beneath a new unsewered subdivision
Wilcox, J.D.; Bradbury, K.R.; Thomas, C.L.; Bahr, J.M.
2005-01-01
Previous site-specific studies designed to assess the impacts of unsewered subdivisions on ground water quality have relied on upgradient monitoring wells or very limited background data to characterize conditions prior to development. In this study, an extensive monitoring program was designed to document ground water conditions prior to construction of a rural subdivision in south-central Wisconsin. Previous agricultural land use has impacted ground water quality; concentrations of chloride, nitrate-nitrogen, and atrazine ranged from below the level of detection to 296 mg/L, 36 mg/L, and 0.8 ??g/L, respectively, and were highly variable from well to well and through time. Seasonal variations in recharge, surface topography, aquifer heterogeneities, surficial loading patterns, and well casing depth explain observed variations in ground water chemistry. This variability would not have been detected if background conditions were determined from only a few monitoring wells or inferred from wells located upgradient of the subdivision site. This project demonstrates the importance of characterizing both ground water quality and chemical variability prior to land-use change to detect any changes once homes are constructed. Copyright ?? 2005 National Ground Water Association.
Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan
2018-01-01
A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized. PMID:29414849
Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan
2018-02-07
A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.
Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies
Kjome, Reidun L. S.; Granas, Anne G.; Nerhus, Kari; Sandberg, Sverre
2009-01-01
Objective To evaluate diabetes patients’ self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. Methods The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201+ by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. Results During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001). Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. Conclusion A community pharmacy-based quality assessment procedure of patients’ self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the patients’ measurements was good and did not improve further during the study. The high analytical quality might be explained by a selection bias of participating patients. Patients also reported increased confidence in their blood glucose measurements after their measurements had been assessed at the pharmacy. PMID:25152795
NASA Astrophysics Data System (ADS)
Marzocchi, W.
2011-12-01
Eruption forecasting is the probability of eruption in a specific time-space-magnitude window. The use of probabilities to track the evolution of a phase of unrest is unavoidable for two main reasons: first, eruptions are intrinsically unpredictable in a deterministic sense, and, second, probabilities represent a quantitative tool that can be rationally used by decision-makers (this is usually done in many other fields). The primary information for the probability assessment during a phase of unrest come from monitoring data of different quantities, such as the seismic activity, ground deformation, geochemical signatures, and so on. Nevertheless, the probabilistic forecast based on monitoring data presents two main difficulties. First, many high-risk volcanoes do not have monitoring pre-eruptive and unrest databases, making impossible a probabilistic assessment based on the frequency of past observations. The ongoing project WOVOdat (led by Christopher Newhall) is trying to tackle this limitation creating a sort of worldwide epidemiological database that may cope with the lack of monitoring pre-eruptive and unrest databases for a specific volcano using observations of 'analogs' volcanoes. Second, the quantity and quality of monitoring data are rapidly increasing in many volcanoes, creating strongly inhomogeneous dataset. In these cases, classical statistical analysis can be performed on high quality monitoring observations only for (usually too) short periods of time, or alternatively using only few specific monitoring data that are available for longer times (such as the number of earthquakes), therefore neglecting a lot of information carried out by the most recent kind of monitoring. Here, we explore a possible strategy to cope with these limitations. In particular, we present a Bayesian strategy that merges different kinds of information. In this approach, all relevant monitoring observations are embedded into a probabilistic scheme through expert opinion, conceptual models, and, possibly, real past data. After discussing all scientific and philosophical aspects of such approach, we present some applications for Campi Flegrei and Vesuvius.
Soekarjo, Damayanti; Zehner, Elizabeth
2011-10-01
It is important to support women to exclusively breastfeed for 6 months and continue breastfeeding for 24 months and beyond. It is also necessary to provide the poor with access to affordable ways to improve the quality of complementary foods. Currently, many countries do not have the legal and policy environment necessary to support exclusive and continued breastfeeding. Legislative and policy changes are also necessary for introducing complementary food supplements, allowing them to be marketed to those who need them, and ensuring that marketing remains appropriate and in full compliance with the International Code of Marketing of Breastmilk Substitutes. This paper aims to illustrate the above with examples from Indonesia and to identify legislative requirements for supporting breastfeeding and enabling appropriate access to high-quality complementary food supplements for children 6-24 months of age. Requirements include improved information, training, monitoring and enforcement systems for the International Code of Marketing of Breastmilk Substitutes; implementation and monitoring of the Baby-Friendly Hospital Initiative; establishment of a registration category for complementary food supplements to enhance availability of high-quality, low-cost fortified products to help improve young child feeding; clear identification and marketing of these products as complementary food supplements for 6-24-month-olds so as to promote proper use and not interfere with breastfeeding. © 2011 Blackwell Publishing Ltd.
Highly survivable bed pressure mat remote patient monitoring system for mHealth.
Joshi, Vilas; Holtzman, Megan; Arcelus, Amaya; Goubran, Rafik; Knoefel, Frank
2012-01-01
The high speed mobile networks like 4G and beyond are making a ubiquitous remote patient monitoring (RPM) system using multiple sensors and wireless sensor networks a realistic possibility. The high speed wireless RPM system will be an integral part of the mobile health (mHealth) paradigm reducing cost and providing better service to the patients. While the high speed wireless RPM system will allow clinicians to monitor various chronic and acute medical conditions, the reliability of such system will depend on the network Quality of Service (QoS). The RPM system needs to be resilient to temporary reduced network QoS. This paper presents a highly survivable bed pressure mat RPM system design using an adaptive information content management methodology for the monitored sensor data. The proposed design improves the resiliency of the RPM system under adverse network conditions like congestion and/or temporary loss of connectivity. It also shows how the proposed RPM system can reduce the information rate and correspondingly reduce the data transfer rate by a factor of 5.5 and 144 to address temporary network congestion. The RPM system data rate reduction results in a lower specificity and sensitivity for the features being monitored but increases the survivability of the system from 1 second to 2.4 minutes making it highly robust.
MAINTAINING DATA QUALITY IN THE PERFORMANCE OF A LARGE SCALE INTEGRATED MONITORING EFFORT
Macauley, John M. and Linda C. Harwell. In press. Maintaining Data Quality in the Performance of a Large Scale Integrated Monitoring Effort (Abstract). To be presented at EMAP Symposium 2004: Integrated Monitoring and Assessment for Effective Water Quality Management, 3-7 May 200...
Overview of the new National Near-Road Air Quality Monitoring Network
In 2010, EPA promulgated new National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2). As part of this new NAAQS, EPA required the establishment of a national near-road air quality monitoring network. This network will consist of one NO2 near-road monitoring st...
Air Quality Monitoring and Sensor Technologies
EPA scientist Ron Williams presented on the features, examination, application, examples, and data quality of continuous monitoring study designs at EPA's Community Air Monitoring Training in July 2015.
Agricultural Land Use mapping by multi-sensor approach for hydrological water quality monitoring
NASA Astrophysics Data System (ADS)
Brodsky, Lukas; Kodesova, Radka; Kodes, Vit
2010-05-01
The main objective of this study is to demonstrate potential of operational use of the high and medium resolution remote sensing data for hydrological water quality monitoring by mapping agriculture intensity and crop structures. In particular use of remote sensing mapping for optimization of pesticide monitoring. The agricultural mapping task is tackled by means of medium spatial and high temporal resolution ESA Envisat MERIS FR images together with single high spatial resolution IRS AWiFS image covering the whole area of interest (the Czech Republic). High resolution data (e.g. SPOT, ALOS, Landsat) are often used for agricultural land use classification, but usually only at regional or local level due to data availability and financial constraints. AWiFS data (nominal spatial resolution 56 m) due to the wide satellite swath seems to be more suitable for use at national level. Nevertheless, one of the critical issues for such a classification is to have sufficient image acquisitions over the whole vegetation period to describe crop development in appropriate way. ESA MERIS middle-resolution data were used in several studies for crop classification. The high temporal and also spectral resolution of MERIS data has indisputable advantage for crop classification. However, spatial resolution of 300 m results in mixture signal in a single pixel. AWiFS-MERIS data synergy brings new perspectives in agricultural Land Use mapping. Also, the developed methodology procedure is fully compatible with future use of ESA (GMES) Sentinel satellite images. The applied methodology of hybrid multi-sensor approach consists of these main stages: a/ parcel segmentation and spectral pre-classification of high resolution image (AWiFS); b/ ingestion of middle resolution (MERIS) vegetation spectro-temporal features; c/ vegetation signatures unmixing; and d/ semantic object-oriented classification of vegetation classes into final classification scheme. These crop groups were selected to be classified: winter crops, spring crops, oilseed rape, legumes, summer and other crops. This study highlights operational potentials of high temporal full resolution MERIS images in agricultural land use monitoring. Practical application of this methodology is foreseen, among others, in the water quality monitoring. Effective pesticide monitoring relies also on spatial distribution of applied pesticides, which can be derived from crop - plant protection product relationship. Knowledge of areas with predominant occurrence of specific crop based on remote sensing data described above can be used for a forecast of probable plant protection product application, thus cost-effective pesticide monitoring. The remote sensing data used on a continuous basis can be used in other long-term water management issues and provide valuable data for decision makers. Acknowledgement: Authors acknowledge the financial support of the Ministry of Education, Youth and Sports of the Czech Republic (grants No. 2B06095 and No. MSM 6046070901). The study was also supported by ESA CAT-1 (ref. 4358) and SOSI projects (Spatial Observation Services and Infrastructure; ref. GSTP-RTDA-EOPG-SW-08-0004).
Improve EPA's AIRNow Air Quality Index Maps with NASA/NOAA Satellite Data
NASA Astrophysics Data System (ADS)
Pasch, A.; Zahn, P. H.; DeWinter, J. L.; Haderman, M. D.; White, J. E.; Dickerson, P.; Dye, T. S.; Martin, R. V.
2011-12-01
The U.S. Environmental Protection Agency's (EPA) AIRNow program provides maps of real-time hourly Air Quality Index (AQI) conditions and daily AQI forecasts nationwide (http://www.airnow.gov). The public uses these maps to make decisions concerning their respiratory health. The usefulness of the AIRNow air quality maps depends on the accuracy and spatial coverage of air quality measurements. Currently, the maps use only ground-based measurements, which have significant gaps in coverage in some parts of the United States. As a result, contoured AQI levels have high uncertainty in regions far from monitors. To improve the usefulness of air quality maps, scientists at EPA and Sonoma Technology, Inc. are working in collaboration with the National Aeronautics and Space Administration (NASA), the National Oceanic and Atmospheric Administration (NOAA), and university researchers on a project to incorporate additional measurements into the maps via the AIRNow Satellite Data Processor (ASDP). These measurements include estimated surface PM
Di Paolo, Carolina; Ottermanns, Richard; Keiter, Steffen; Ait-Aissa, Selim; Bluhm, Kerstin; Brack, Werner; Breitholtz, Magnus; Buchinger, Sebastian; Carere, Mario; Chalon, Carole; Cousin, Xavier; Dulio, Valeria; Escher, Beate I; Hamers, Timo; Hilscherová, Klára; Jarque, Sergio; Jonas, Adam; Maillot-Marechal, Emmanuelle; Marneffe, Yves; Nguyen, Mai Thao; Pandard, Pascal; Schifferli, Andrea; Schulze, Tobias; Seidensticker, Sven; Seiler, Thomas-Benjamin; Tang, Janet; van der Oost, Ron; Vermeirssen, Etienne; Zounková, Radka; Zwart, Nick; Hollert, Henner
2016-11-01
Bioassays are particularly useful tools to link the chemical and ecological assessments in water quality monitoring. Different methods cover a broad range of toxicity mechanisms in diverse organisms, and account for risks posed by non-target compounds and mixtures. Many tests are already applied in chemical and waste assessments, and stakeholders from the science-police interface have recommended their integration in regulatory water quality monitoring. Still, there is a need to address bioassay suitability to evaluate water samples containing emerging pollutants, which are a current priority in water quality monitoring. The presented interlaboratory study (ILS) verified whether a battery of miniaturized bioassays, conducted in 11 different laboratories following their own protocols, would produce comparable results when applied to evaluate blinded samples consisting of a pristine water extract spiked with four emerging pollutants as single chemicals or mixtures, i.e. triclosan, acridine, 17α-ethinylestradiol (EE2) and 3-nitrobenzanthrone (3-NBA). Assays evaluated effects on aquatic organisms from three different trophic levels (algae, daphnids, zebrafish embryos) and mechanism-specific effects using in vitro estrogenicity (ER-Luc, YES) and mutagenicity (Ames fluctuation) assays. The test battery presented complementary sensitivity and specificity to evaluate the different blinded water extract spikes. Aquatic organisms differed in terms of sensitivity to triclosan (algae > daphnids > fish) and acridine (fish > daphnids > algae) spikes, confirming the complementary role of the three taxa for water quality assessment. Estrogenicity and mutagenicity assays identified with high precision the respective mechanism-specific effects of spikes even when non-specific toxicity occurred in mixture. For estrogenicity, although differences were observed between assays and models, EE2 spike relative induction EC 50 values were comparable to the literature, and E2/EE2 equivalency factors reliably reflected the sample content. In the Ames, strong revertant induction occurred following 3-NBA spike incubation with the TA98 strain, which was of lower magnitude after metabolic transformation and when compared to TA100. Differences in experimental protocols, model organisms, and data analysis can be sources of variation, indicating that respective harmonized standard procedures should be followed when implementing bioassays in water monitoring. Together with other ongoing activities for the validation of a basic bioassay battery, the present study is an important step towards the implementation of bioanalytical monitoring tools in water quality assessment and monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
Quality assurance report - Loch Vale Watershed, 1999-2002
Botte, Jorin A.; Baron, Jill S.
2004-01-01
The National Park Service initiated the Loch Vale Watershed (LVWS) project in 1980 with funding from the Aquatic Effects Research Program of the National Acid Precipitation Assessment Program. Long-term ecological research and monitoring address watershed-scale ecosystem processes, particularly as they respond to atmospheric deposition and climate variability. Monitoring of meteorological, hydrologic, precipitation chemistry, and surface water quality parameters enable us to use long-term trends to distinguish natural from human-caused disturbances. Research into snow distribution, hydrologic flowpaths, vegetation responses to N deposition, isotopic transformations of N by forest and soil processes, trace metals, and aquatic ecological responses to disturbance enable us to understand processes that influence high elevation ecosystems.
Motion-blur-compensated structural health monitoring system for tunnels at a speed of 100 km/h
NASA Astrophysics Data System (ADS)
Hayakawa, Tomohiko; Ishikawa, Masatoshi
2017-04-01
High quality images of tunnel surfaces are necessary for visual judgment of abnormal parts. Hence, we propose a monitoring system from a vehicle, which is motion-blur-compensated by the back and forth motion of a galvanometer mirror to offset the vehicle speed, prolong exposure time, and take sharp images including detailed textures. As experimental result of the vehicle-mounted system, we confirmed significant improvements in image quality for a few millimeter-sized ordered black-and-white stripes and cracks, by means of motion blur compensation and prolonged exposure time, under the maximum speed allowed in Japan in a standard tunnel of a highway.
A real-time monitoring system for night glare protection
NASA Astrophysics Data System (ADS)
Ma, Jun; Ni, Xuxiang
2010-11-01
When capturing a dark scene with a high bright object, the monitoring camera will be saturated in some regions and the details will be lost in and near these saturated regions because of the glare vision. This work aims at developing a real-time night monitoring system. The system can decrease the influence of the glare vision and gain more details from the ordinary camera when exposing a high-contrast scene like a car with its headlight on during night. The system is made up of spatial light modulator (The liquid crystal on silicon: LCoS), image sensor (CCD), imaging lens and DSP. LCoS, a reflective liquid crystal, can modular the intensity of reflective light at every pixel as a digital device. Through modulation function of LCoS, CCD is exposed with sub-region. With the control of DSP, the light intensity is decreased to minimum in the glare regions, and the light intensity is negative feedback modulated based on PID theory in other regions. So that more details of the object will be imaging on CCD and the glare protection of monitoring system is achieved. In experiments, the feedback is controlled by the embedded system based on TI DM642. Experiments shows: this feedback modulation method not only reduces the glare vision to improve image quality, but also enhances the dynamic range of image. The high-quality and high dynamic range image is real-time captured at 30hz. The modulation depth of LCoS determines how strong the glare can be removed.
NASA Astrophysics Data System (ADS)
Lipenbergs, E.; Bobrovs, Vj.; Ivanovs, G.
2016-10-01
To ensure that end-users and consumers have access to comprehensive, comparable and user-friendly information regarding the Internet access service quality, it is necessary to implement and regularly renew a set of legislative regulatory acts and to provide monitoring of the quality of Internet access services regarding the current European Regulatory Framework. The actual situation regarding the quality of service monitoring solutions in different European countries depends on national regulatory initiatives and public awareness. The service monitoring solutions are implemented using different measurement methodologies and tools. The paper investigates the practical implementations for developing a harmonising approach to quality monitoring in order to obtain objective information on the quality of Internet access services on mobile networks.
WSN based indoor air quality monitoring in classrooms
NASA Astrophysics Data System (ADS)
Wang, S. K.; Chew, S. P.; Jusoh, M. T.; Khairunissa, A.; Leong, K. Y.; Azid, A. A.
2017-03-01
Indoor air quality monitoring is essential as the human health is directly affected by indoor air quality. This paper presents the investigations of the impact of undergraduate students' concentration during lecture due to the indoor air quality in classroom. Three environmental parameters such as temperature, relative humidity and concentration of carbon dioxide are measured using wireless sensor network based air quality monitoring system. This simple yet reliable system is incorporated with DHT-11 and MG-811 sensors. Two classrooms were selected to install the monitoring system. The level of indoor air quality were measured and students' concentration was assessed using intelligent test during normal lecturing section. The test showed significant correlation between the collected environmental parameters and the students' level of performances in their study.
Quality of Care for Patients with Type 2 Diabetes Mellitus in Dubai: A HEDIS-Like Assessment
Szabo, Shelagh M.; Osenenko, Katherine M.; Qatami, Lara; Korenblat Donato, Bonnie M.; Korol, Ellen E.; Al Madani, Abdulrazzaq A.; Al Awadi, Fatheya F.; Al-Ansari, Jaber; Maclean, Ross; Levy, Adrian R.
2015-01-01
Objective. As little data are available on the quality of type 2 diabetes mellitus (T2DM) care in the Arabian Gulf States, we estimated the proportion of patients receiving recommended monitoring at the Dubai Hospital for T2DM over one year. Methods. Charts from 150 adults with T2DM were systematically sampled and quality of care was assessed during one calendar year, using a Healthcare Effectiveness Data and Information Set- (HEDIS-) like assessment. Screening for glycosylated haemoglobin (HbA1c), low-density lipoprotein (LDL), blood pressure, retinopathy, and nephropathy was considered. Patients were classified based on their most recent test in the period, and predictors of receiving quality care were examined. Results. Mean age was 58 years (standard deviation (SD): 12.4 years) and 33% were males. Over the year, 98% underwent HbA1c screening (50% had control and 28% displayed poor control); 91% underwent LDL screening (65% had control); 55% had blood pressure control; 30% had retinopathy screening; and 22% received attention for nephropathy. No individual characteristics examined predicted receiving quality care. Conclusion. Some guideline monitoring was conducted for most patients; and rates of monitoring for selected measures were comparable to benchmarks from the United States. Greater understanding of factors leading to high adherence would be useful for other areas of preventive care and other jurisdictions. PMID:26089885
Quality of Care for Patients with Type 2 Diabetes Mellitus in Dubai: A HEDIS-Like Assessment.
Szabo, Shelagh M; Osenenko, Katherine M; Qatami, Lara; Korenblat Donato, Bonnie M; Korol, Ellen E; Al Madani, Abdulrazzaq A; Al Awadi, Fatheya F; Al-Ansari, Jaber; Maclean, Ross; Levy, Adrian R
2015-01-01
Objective. As little data are available on the quality of type 2 diabetes mellitus (T2DM) care in the Arabian Gulf States, we estimated the proportion of patients receiving recommended monitoring at the Dubai Hospital for T2DM over one year. Methods. Charts from 150 adults with T2DM were systematically sampled and quality of care was assessed during one calendar year, using a Healthcare Effectiveness Data and Information Set- (HEDIS-) like assessment. Screening for glycosylated haemoglobin (HbA1c), low-density lipoprotein (LDL), blood pressure, retinopathy, and nephropathy was considered. Patients were classified based on their most recent test in the period, and predictors of receiving quality care were examined. Results. Mean age was 58 years (standard deviation (SD): 12.4 years) and 33% were males. Over the year, 98% underwent HbA1c screening (50% had control and 28% displayed poor control); 91% underwent LDL screening (65% had control); 55% had blood pressure control; 30% had retinopathy screening; and 22% received attention for nephropathy. No individual characteristics examined predicted receiving quality care. Conclusion. Some guideline monitoring was conducted for most patients; and rates of monitoring for selected measures were comparable to benchmarks from the United States. Greater understanding of factors leading to high adherence would be useful for other areas of preventive care and other jurisdictions.
Johnson, Steven M.; Swanson, Robert B.
1994-01-01
Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.
A Pilot Study of Microbial Contamination of Subtropical Recreational Waters
Fleming, Lora E; Solo, Gabriele H.; Elmir, Samir; Shibata, Tomoyuki; Squicciarini, Dominick; Quirino, Wendy; Arguello, Margia; Van de Bogart, Gayl
2009-01-01
Microbial water quality indicators are used to determine whether a water body is safe for recreational purposes. There have been concerns raised about the appropriate use of microbial indicators to regulate recreational uses of water bodies, in particular those located in tropical and sub-tropical environments. This prospective cohort pilot study evaluated the relationship between microbial water quality indicators and public health within two public beaches without known sewage discharge, but with historically high microbial levels for one beach, in subtropical Miami-Dade County (Florida). Monitoring was conducted in three phases: daily water monitoring, beach sand sampling, and spatially intense water sampling. An epidemiological questionnaire from a Los Angeles recreational beach-goer study was used to assess the self-reported swimming-related symptoms and exposures. There was no significant association between the number nor the type of reported symptoms and the different sampling months or beach sites, although persons who returned repeatedly to the beach were more likely to report symptoms. The number of indicator organisms correlated negatively with the frequency of symptoms reported by recreational beach goers. Results of the daily monitoring indicated that different indicators provided conflicting results concerning beach water quality. Larger epidemiologic studies with individual exposure monitoring are recommended to further evaluate these potentially important associations in subtropical recreational waters. PMID:20151031
Feasibility analysis of marine ecological on-line integrated monitoring system
NASA Astrophysics Data System (ADS)
Chu, D. Z.; Cao, X.; Zhang, S. W.; Wu, N.; Ma, R.; Zhang, L.; Cao, L.
2017-08-01
The in-situ water quality sensors were susceptible to biological attachment. Moreover, sea water corrosion and wave impact damage, and many sensors scattered distribution would cause maintenance inconvenience. The paper proposed a highly integrated marine ecological on-line integrated monitoring system, which can be used inside monitoring station. All sensors were reasonably classified, the similar in series, the overall in parallel. The system composition and workflow were described. In addition, the paper proposed attention issues of the system design and corresponding solutions. Water quality multi-parameters and 5 nutrient salts as the verification index, in-situ and systematic data comparison experiment were carried out. The results showed that the data consistency of nutrient salt, PH and salinity was better. Temperature and dissolved oxygen data trend was consistent, but the data had deviation. Turbidity fluctuated greatly; the chlorophyll trend was similar with it. Aiming at the above phenomena, three points system optimization direction were proposed.
[Low-power Wireless Micro Ambulatory Electrocardiogram Node].
Cai, Zhipeng; Luo, Kan; Li, Jianqing
2016-02-01
Ambulatory electrocardiogram (ECG) monitoring can effectively reduce the risk and death rate of patients with cardiovascular diseases (CVDs). The Body Sensor Network (BSN) based ECG monitoring is a new and efficien method to protect the CVDs patients. To meet the challenges of miniaturization, low power and high signal quality of the node, we proposed a novel 50 mmX 50 mmX 10 mm, 30 g wireless ECG node, which includes the single-chip an alog front-end AD8232, ultra-low power microprocessor MSP430F1611 and Bluetooth module HM-11. The ECG signal quality is guaranteed by the on-line digital filtering. The difference threshold algorithm results in accuracy of R-wave detection and heart rate. Experiments were carried out to test the node and the results showed that the pro posed node reached the design target, and it has great potential in application of wireless ECG monitoring.
3D Printing-Based Integrated Water Quality Sensing System
Banna, Muinul; Bera, Kaustav; Sochol, Ryan; Lin, Liwei; Najjaran, Homayoun; Sadiq, Rehan; Hoorfar, Mina
2017-01-01
The online and accurate monitoring of drinking water supply networks is critically in demand to rapidly detect the accidental or deliberate contamination of drinking water. At present, miniaturized water quality monitoring sensors developed in the laboratories are usually tested under ambient pressure and steady-state flow conditions; however, in Water Distribution Systems (WDS), both the pressure and the flowrate fluctuate. In this paper, an interface is designed and fabricated using additive manufacturing or 3D printing technology—material extrusion (Trade Name: fused deposition modeling, FDM) and material jetting—to provide a conduit for miniaturized sensors for continuous online water quality monitoring. The interface is designed to meet two main criteria: low pressure at the inlet of the sensors and a low flowrate to minimize the water bled (i.e., leakage), despite varying pressure from WDS. To meet the above criteria, a two-dimensional computational fluid dynamics model was used to optimize the geometry of the channel. The 3D printed interface, with the embedded miniaturized pH and conductivity sensors, was then tested at different temperatures and flowrates. The results show that the response of the pH sensor is independent of the flowrate and temperature. As for the conductivity sensor, the flowrate and temperature affect only the readings at a very low conductivity (4 µS/cm) and high flowrates (30 mL/min), and a very high conductivity (460 µS/cm), respectively. PMID:28594387
Evaluation of Elm and Speck Sensors
Particulate matter (PM) is a pollutant of high public interest regulated by national ambient air quality standards (NAAQS) using Federal Reference Method (FRM) and Federal Equivalent Method (FEM) instrumentation identified for environmental monitoring. The US EPA has been evaluat...
Otto, Kristen J; Hapner, Edie R; Baker, Michael; Johns, Michael M
2006-02-01
Advances in commercial video technology have improved office-based laryngeal imaging. This study investigates the perceived image quality of a true high-definition (HD) video camera and the effect of magnification on laryngeal videostroboscopy. We performed a prospective, dual-armed, single-blinded analysis of a standard laryngeal videostroboscopic examination comparing 3 separate add-on camera systems: a 1-chip charge-coupled device (CCD) camera, a 3-chip CCD camera, and a true 720p (progressive scan) HD camera. Displayed images were controlled for magnification and image size (20-inch [50-cm] display, red-green-blue, and S-video cable for 1-chip and 3-chip cameras; digital visual interface cable and HD monitor for HD camera). Ten blinded observers were then asked to rate the following 5 items on a 0-to-100 visual analog scale: resolution, color, ability to see vocal fold vibration, sense of depth perception, and clarity of blood vessels. Eight unblinded observers were then asked to rate the difference in perceived resolution and clarity of laryngeal examination images when displayed on a 10-inch (25-cm) monitor versus a 42-inch (105-cm) monitor. A visual analog scale was used. These monitors were controlled for actual resolution capacity. For each item evaluated, randomized block design analysis demonstrated that the 3-chip camera scored significantly better than the 1-chip camera (p < .05). For the categories of color and blood vessel discrimination, the 3-chip camera scored significantly better than the HD camera (p < .05). For magnification alone, observers rated the 42-inch monitor statistically better than the 10-inch monitor. The expense of new medical technology must be judged against its added value. This study suggests that HD laryngeal imaging may not add significant value over currently available video systems, in perceived image quality, when a small monitor is used. Although differences in clarity between standard and HD cameras may not be readily apparent on small displays, a large display size coupled with HD technology may impart improved diagnosis of subtle vocal fold lesions and vibratory anomalies.
Voluntary Compliance, Pollution Levels, and Infant Mortality in Mexico.
Foster, Andrew; Gutierrez, Emilio; Kumar, Naresh
2009-05-01
The increasing body of evidence from high income countries linking pollution to health outcomes (Ken Chay and Michael Greenstone 2003; Janet Currie and Matthew Neidell 2004), has raised concerns about the health impact of adverse air quality in developing countries, where, in general, environmental regulation is less stringent and health monitoring and treatment are less accessible. These concerns have, in turn, encouraged consideration of the effectiveness of alternative mechanisms for improving air quality while limiting the adverse impact on economic growth. However, the analysis of both the effects of pollution on health and the effectiveness of pollution abatement policies faces particular empirical challenges in low- and middle-income contexts, given the scarcity of reliable measures of pollution concentrations. The primary source of good quality data on air quality, ground monitoring, tends to be limited to larger metropolitan areas with monitors placed at sentinel sites that may or may not yield a representative picture of population exposure. This paper calls attention to, and makes use of, newly available procedures for extracting measures of air quality from satellite imagery. In particular, satellite-based measures of aerosol optical depth (AOD) are used to obtain estimates of air quality for the whole Mexican territory at a detailed geographic scale, and these estimates are related to measures of participation in a voluntary certification program at the level of the county. The resulting estimates are then combined with estimates of the relationship between participation in the certification program and infant mortality due to respiratory causes to obtain a rough estimate of the relationship between air quality and infant health in Mexico.
McDonough, Ian M; Bui, Dung C; Friedman, Michael C; Castel, Alan D
2015-10-01
The perceived value of information can influence one's motivation to successfully remember that information. This study investigated how information value can affect memory search and evaluation processes (i.e., retrieval monitoring). In Experiment 1, participants studied unrelated words associated with low, medium, or high values. Subsequent memory tests required participants to selectively monitor retrieval for different values. False memory effects were smaller when searching memory for high-value than low-value words, suggesting that people more effectively monitored more important information. In Experiment 2, participants studied semantically-related words, and the need for retrieval monitoring was reduced at test by using inclusion instructions (i.e., endorsement of any word related to the studied words) compared with standard instructions. Inclusion instructions led to increases in false recognition for low-value, but not for high-value words, suggesting that under standard-instruction conditions retrieval monitoring was less likely to occur for important information. Experiment 3 showed that words retrieved with lower confidence were associated with more effective retrieval monitoring, suggesting that the quality of the retrieved memory influenced the degree and effectiveness of monitoring processes. Ironically, unless encouraged to do so, people were less likely to carefully monitor important information, even though people want to remember important memories most accurately. Copyright © 2015 Elsevier B.V. All rights reserved.
Rocker, Melissa M; Francis, David S; Fabricius, Katharina E; Willis, Bette L; Bay, Line K
2017-06-30
This study explores how plasticity in biochemical attributes, used as indicators of health and condition, enables the coral Acropora tenuis to respond to differing water quality regimes in inshore regions of the Great Barrier Reef. Health attributes were monitored along a strong and weak water quality gradient, each with three reefs at increasing distances from a major river source. Attributes differed significantly only along the strong gradient; corals grew fastest, had the least dense skeletons, highest symbiont densities and highest lipid concentrations closest to the river mouth, where water quality was poorest. High nutrient and particulate loads were only detrimental to skeletal density, which decreased as linear extension increased, highlighting a trade-off. Our study underscores the importance of assessing multiple health attributes in coral reef monitoring. For example, autotrophic indices are poor indicators of coral health and condition, but improve when combined with attributes like lipid content and biomass. Copyright © 2017 Elsevier Ltd. All rights reserved.
Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui
2015-05-01
The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.
U.S. Geological Survey continuous monitoring workshop—Workshop summary report
Sullivan, Daniel J.; Joiner, John K.; Caslow, Kerry A.; Landers, Mark N.; Pellerin, Brian A.; Rasmussen, Patrick P.; Sheets, Rodney A.
2018-04-20
Executive SummaryThe collection of high-frequency (in other words, “continuous”) water data has been made easier over the years because of advances in technologies to measure, transmit, store, and query large, temporally dense datasets. Commercially available, in-situ sensors and data-collection platforms—together with new techniques for data analysis—provide an opportunity to monitor water quantity and quality at time scales during which meaningful changes occur. The U.S. Geological Survey (USGS) Continuous Monitoring Workshop was held to build stronger collaboration within the Water Mission Area on the collection, interpretation, and application of continuous monitoring data; share technical approaches for the collection and management of continuous data that improves consistency and efficiency across the USGS; and explore techniques and tools for the interpretation of continuous monitoring data, which increases the value to cooperators and the public. The workshop was organized into three major themes: Collecting Continuous Data, Understanding and Using Continuous Data, and Observing and Delivering Continuous Data in the Future. Presentations each day covered a variety of related topics, with a special session at the end of each day designed to bring discussion and problem solving to the forefront.The workshop brought together more than 70 USGS scientists and managers from across the Water Mission Area and Water Science Centers. Tools to manage, assure, control quality, and explore large streams of continuous water data are being developed by the USGS and other organizations and will be critical to making full use of these high-frequency data for research and monitoring. Disseminating continuous monitoring data and findings relevant to critical cooperator and societal issues is central to advancing the USGS networks and mission. Several important outcomes emerged from the presentations and breakout sessions.
Laing, Judy
Article 16 of the United Nations Convention on the Rights of Persons with Disabilities includes the right to be free from all forms of violence, exploitation and abuse. In pursuance of this aim, Article 16 (3) imposes an obligation on States Parties to 'ensure that all facilities and programmes designed to serve persons with disabilities are effectively monitored by independent authorities'. Effective independent monitoring is viewed as a key mechanism to help safeguard people from violence, exploitation and abuse. This is highly pertinent in the wake of the highly publicized abuse of patients in care homes and hospitals in England in the last few years. This article examines the monitoring requirements of Article 16 and, by drawing on the author's research into the Care Quality Commission (the national health and social care regulator and mental health monitor) in England, assesses the extent to which independent inspection of hospitals and care homes can play a part in realizing Article 16(3) to prevent violence, abuse and exploitation of persons with mental disabilities. The potential scope and reach of Article 16 is extremely wide: this brings with it great potential but, at the same time, significant challenges for achieving effecting monitoring. Some of these challenges are explored and the paper concludes with some consideration of how monitors/inspectors, such as the Care Quality Commission in England, can strengthen their protection for people with mental disabilities, in line with the ethos and aspirations of the CRPD. Copyright © 2017 Elsevier Ltd. All rights reserved.
Crocker, Jonny; Bartram, Jamie
2014-07-18
Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country's ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries.
Pope, Ronald; Wu, Jianguo
2014-06-01
In the United States, air pollution is primarily measured by Air Quality Monitoring Networks (AQMN). These AQMNs have multiple objectives, including characterizing pollution patterns, protecting the public health, and determining compliance with air quality standards. In 2006, the U.S. Environmental Protection Agency issued a directive that air pollution agencies assess the performance of their AQMNs. Although various methods to design and assess AQMNs exist, here we demonstrate a geographic information system (GIS)-based approach that combines environmental, economic, and social indicators through the assessment of the ozone (O3) and particulate matter (PM10) networks in Maricopa County, Arizona. The assessment was conducted in three phases: (1) to evaluate the performance of the existing networks, (2) to identify areas that would benefit from the addition of new monitoring stations, and (3) to recommend changes to the AQMN. A comprehensive set of indicators was created for evaluating differing aspects of the AQMNs' objectives, and weights were applied to emphasize important indicators. Indicators were also classified according to their sustainable development goal. Our results showed that O3 was well represented in the county with some redundancy in terms of the urban monitors. The addition of weights to the indicators only had a minimal effect on the results. For O3, urban monitors had greater social scores, while rural monitors had greater environmental scores. The results did not suggest a need for adding more O3 monitoring sites. For PM10, clustered urban monitors were redundant, and weights also had a minimal effect on the results. The clustered urban monitors had overall low scores; sites near point sources had high environmental scores. Several areas were identified as needing additional PM10 monitors. This study demonstrates the usefulness of a multi-indicator approach to assess AQMNs. Network managers and planners may use this method to assess the performance of air quality monitoring networks in urban regions. The U.S. Environmental Protection Agency issued a directive in 2006 that air pollution agencies assess the performance of their AQMNs; as a result, we developed a GIS-based, multi-objective assessment approach that integrates environmental, economic, and social indicators, and demonstrates its use through assessing the O3 and PM10 monitoring networks in the Phoenix metropolitan area. We exhibit a method of assessing network performance and identifying areas that would benefit from new monitoring stations; also, we demonstrate the effect of adding weights to the indicators. Our study shows that using a multi-indicator approach gave detailed assessment results for the Phoenix AQMN.
Using a crowdsourced approach for monitoring water level in a remote Kenyan catchment
NASA Astrophysics Data System (ADS)
Weeser, Björn; Jacobs, Suzanne; Rufino, Mariana; Breuer, Lutz
2017-04-01
Hydrological models or effective water management strategies only succeed if they are based on reliable data. Decreasing costs of technical equipment lower the barrier to create comprehensive monitoring networks and allow both spatial and temporal high-resolution measurements. However, these networks depend on specialised equipment, supervision, and maintenance producing high running expenses. This becomes particularly challenging for remote areas. Low income countries often do not have the capacity to run such networks. Delegating simple measurements to citizens living close to relevant monitoring points may reduce costs and increase the public awareness. Here we present our experiences of using a crowdsourced approach for monitoring water levels in remote catchments in Kenya. We established a low-cost system consisting of thirteen simple water level gauges and a Raspberry Pi based SMS-Server for data handling. Volunteers determine the water level and transmit their records using a simple text message. These messages are automatically processed and real-time feedback on the data quality is given. During the first year, more than 1200 valid records with high quality have been collected. In summary, the simple techniques for data collecting, transmitting and processing created an open platform that has the potential for reaching volunteers without the need for special equipment. Even though the temporal resolution of measurements cannot be controlled and peak flows might be missed, this data can still be considered as a valuable enhancement for developing management strategies or for hydrological modelling.
Quality Control of The Norwegian Uv Monitoring Network.
NASA Astrophysics Data System (ADS)
Johnsen, B.; Mikkelborg, O.; Dahlback, A.; Høiskar, B. A.; Kylling, A.; Edvardsen, K.; Olseth, J. A.; Kjeldstad, B.; Ørbæk, J. B.
A Norwegian UV-monitoring network of GUV multiband radiometers has been operating at locations between 59°N to 79°N since 1995-96. The purpose of the network is to obtain data of high scientific quality, to be used in further assessments related to health- and environmental issues. Maintenance of measurement quality is given priority. Spectral response functions, crucial for calibrations, have been obtained for each instrument. Calibrations are traceable to the Nordic intercomparison of UV radiometers held in Sweden in June 2000. Instruments are inspected daily or weekly. Once a year the instruments are compared to travelling standards operating side by side to the local network radiometers. This enables determination of the longterm drift in instrument responses. For the six years period of operation, the steadiest instrument performed stable within +/-3%, whereas the least steady had a response drop by 23%. Comparisons with a true cosine performing spectroradiometer demonstrate close agreement (+/- 2%) for solar zenith angles less than 80°. Good cosine performance, high spectral sensitivity and weatherproof design demonstrate that the GUV radiometers are particularly suitable for UV monitoring at high latitudes. Complete records of corrected daily CIE-effective doses and online measurements are presented on http://uvnett.nrpa.no/. Gaps in measurement series have been corrected for with a clear sky radiative transfer model and hourly UV sky transmittances estimated from pyranometer data. Measurement data and information about the monitoring network may be found by visiting websites at respectively NRPA, NILU and The University of Oslo; http://www.nrpa.no, http://www.nilu.no/uv, http://www.fys.uio.no/plasma/ozone/. At this stage the quality of the network has reached a satisfactory level and it is possible to move on using UV data in further assessments. Trend analyses and UV forecasting are topics for future work. The network is supported by the ministries of Health and Environment and is administered by The Norwegian Radiation Protection Authority and The Norwegian Pollution Control Authority, the latter through The Norwegian Institute for Air Research.
Analytical approaches to quality assurance and quality control in rangeland monitoring data
USDA-ARS?s Scientific Manuscript database
Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...
Monitoring Error Rates In Illumina Sequencing.
Manley, Leigh J; Ma, Duanduan; Levine, Stuart S
2016-12-01
Guaranteeing high-quality next-generation sequencing data in a rapidly changing environment is an ongoing challenge. The introduction of the Illumina NextSeq 500 and the depreciation of specific metrics from Illumina's Sequencing Analysis Viewer (SAV; Illumina, San Diego, CA, USA) have made it more difficult to determine directly the baseline error rate of sequencing runs. To improve our ability to measure base quality, we have created an open-source tool to construct the Percent Perfect Reads (PPR) plot, previously provided by the Illumina sequencers. The PPR program is compatible with HiSeq 2000/2500, MiSeq, and NextSeq 500 instruments and provides an alternative to Illumina's quality value (Q) scores for determining run quality. Whereas Q scores are representative of run quality, they are often overestimated and are sourced from different look-up tables for each platform. The PPR's unique capabilities as a cross-instrument comparison device, as a troubleshooting tool, and as a tool for monitoring instrument performance can provide an increase in clarity over SAV metrics that is often crucial for maintaining instrument health. These capabilities are highlighted.
Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.
Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot
2007-01-04
The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.
Ronveaux, O.; Rickert, D.; Hadler, S.; Groom, H.; Lloyd, J.; Bchir, A.; Birmingham, M.
2005-01-01
OBJECTIVE: To evaluate the consistency and quality of immunization monitoring systems in 27 countries during 2002-03 using standardized data quality audits (DQAs) that had been launched within the framework of the Global Alliance for Vaccines and Immunization. METHODS: The consistency of reporting systems was estimated by determining the proportion of third doses of diphtheria-tetanuspertussis (DTP-3) vaccine reported as being administered that could be verified by written documentation at health facilities and districts. The quality of monitoring systems was measured using quality indices for different components of the monitoring systems. These indices were applied to each level of the health service (health unit, district and national). FINDINGS: The proportion of verified DTP-3 doses was lower than 85% in 16 countries. Difficulties in verifying the doses administered often arose at the peripheral level of the health service, usually as the result of discrepancies in information between health units and their corresponding districts or because completed recording forms were not available from health units. All countries had weaknesses in their monitoring systems; these included the inconsistent use of monitoring charts; inadequate monitoring of vaccine stocks, injection supplies and adverse events; unsafe computer practices; and poor monitoring of completeness and timeliness of reporting. CONCLUSION: Inconsistencies in immunization data occur in many countries, hampering their ability to manage their immunization programmes. Countries should use these findings to strengthen monitoring systems so that data can reliably guide programme activities. The DQA is an innovative tool that provides a way to independently assess the quality of immunization monitoring systems at all levels of a health service and serves as a point of entry to make improvements. It provides a useful example for other global health initiatives. PMID:16175824
NASA Astrophysics Data System (ADS)
Aubert, Alice; Kirchner, James; Faucheux, Mikael; Merot, Philippe; Gascuel-Odoux, Chantal
2013-04-01
The choice of sampling frequency is a key issue in the design and operation of environmental observatories. The choice of sampling frequency creates a spectral window (or temporal filter) that highlights some timescales and processes, and de-emphasizes others (1). New online measurement technologies can monitor surface water quality almost continuously, allowing the creation of very rich time series. The question of how best to analyze such detailed temporal datasets is an important issue in environmental monitoring. In the present work, we studied water quality data from the AgrHys long-term hydrological observatory (located at Kervidy-Naizin, Western France) sampled at daily and 20-minute time scales. Manual sampling has provided 12 years of daily measurements of nitrate, dissolved organic carbon (DOC), chloride and sulfate (2), and 3 years of daily measurements of about 30 other solutes. In addition, a UV-spectrometry probe (Spectrolyser) provides one year of 20-minute measurements for nitrate and DOC. Spectral analysis of the daily water quality time series reveals that our intensively farmed catchment exhibits universal 1/f scaling (power spectrum slope of -1) for a large number of solutes, confirming and extending the earlier discovery of universal 1/f scaling in the relatively pristine Plynlimon catchment (3). 1/f time series confound conventional methods for assessing the statistical significance of trends. Indeed, conventional methods assume that there is a clear separation of scales between the signal (the trend line) and the noise (the scatter around the line). This is not true for 1/f noise, since it overestimates the occurrence of significant trends. Our results raise the possibility that 1/f scaling is widespread in water quality time series, thus posing fundamental challenges to water quality trend analysis. Power spectra of the 20-minute nitrate and DOC time series show 1/f scaling at frequencies below 1/day, consistent with the longer-term daily measurements. At higher frequencies, however, the spectra steepen to a slope of -2, indicating that at sub-daily time scales the concentration time series become relatively smooth. However, at time scales shorter than 2-3 hours, the spectra flatten to a slope near zero (white noise), reflecting analytical noise in the measurement probe. This result demonstrates that measuring water quality dynamics at high frequencies also requires high measurement precision, because as measurements are taken closer and closer together in time, the real-world differences that must be measured between adjacent measurements become smaller and smaller. Our results highlight the importance of quantifying the spectral properties of analytical noise in environmental measurements, to identify frequency ranges where measurements could be dominated by analytical noise instead of real-world signals. 1. Kirchner, J.W., Feng, X., Neal, C., Robson, A.J., 2004. The fine structure of water-quality dynamics: the (high-frequency) wave of the future. Hydrological Processes, 18(7): 1353-1359 2. Aubert, A.H. et al., 2012. The chemical signature of a livestock farming catchment: synthesis from a high-frequency multi-element long term monitoring. HESSD, 9(8): 9715 - 9741 3. Kirchner, J.W. and Neal, C., 2013. Universal fractal scaling in water quality dynamics across the periodic table. Manuscript in review.
We describe here an effort to use high frequency data collected from online, continuous monitors coupled with field collected data to describe the temporal relationship between suspected HAB drivers and observed cyanoHABs and cyanotoxin production to provide insight on the necess...
Monitoring black-tailed prairie dog colonies with high-resolution satellite imagery
Sidle, John G.; Johnson, D.H.; Euliss, B.R.; Tooze, M.
2002-01-01
The United States Fish and Wildlife Service has determined that the black-tailed prairie dog (Cynomys ludovicianus) warrants listing as a threatened species under the Endangered Species Act. Central to any conservation planning for the black-tailed prairie dog is an appropriate detection and monitoring technique. Because coarse-resolution satellite imagery is not adequate to detect black-tailed prairie dog colonies, we examined the usefulness of recently available high-resolution (1-m) satellite imagery. In 6 purchased scenes of national grasslands, we were easily able to visually detect small and large colonies without using image-processing algorithms. The Ikonos (Space Imaging(tm)) satellite imagery was as adequate as large-scale aerial photography to delineate colonies. Based on the high quality of imagery, we discuss a possible monitoring program for black-tailed prairie dog colonies throughout the Great Plains, using the species' distribution in North Dakota as an example. Monitoring plots could be established and imagery acquired periodically to track the expansion and contraction of colonies.
The maladies of water and war: addressing poor water quality in Iraq.
Zolnikov, Tara Rava
2013-06-01
Water is essential in providing nutrients, but contaminated water contributes to poor population health. Water quality and availability can change in unstructured situations, such as war. To develop a practical strategy to address poor water quality resulting from intermittent wars in Iraq, I reviewed information from academic sources regarding waterborne diseases, conflict and war, water quality treatment, and malnutrition. The prevalence of disease was high in impoverished, malnourished populations exposed to contaminated water sources. The data aided in developing a strategy to improve water quality in Iraq, which encompasses remineralized water from desalination plants, health care reform, monitoring and evaluation systems, and educational public health interventions.
NASA Astrophysics Data System (ADS)
Rust, A.; Knipper, K. R.; Randall, J.; Hogue, T. S.
2014-12-01
Forest fires affect water quality in the disrupted watershed, which can devastate the aquatic ecosystem including sensitive trout (Salmonidae) and macroinvertebrate species. The West Fork Fire Complex consumed 88,724 acres of forest in the state of Colorado during the summer of 2013. The majority (88%) of the burn area was comprised of Engelmann spruce (Picea engelmanii) trees killed previously by Spruce Beetle (Ips spp.). Damage to the soils was of moderate to high severity in the majority of the area (60%). The recent fire surrounded the Rio Grande, affecting water quality and habitat critical to insects and fish. The water quality of the Rio Grande (above and below the burn) and some of the effected tributaries is currently being monitored for both quality and quantity. Parameters important to the survival of aquatic life, such as flow, temperature, dissolved oxygen, pH, conductivity, total dissolved solids, total suspended solids, turbidity, nutrients, and suspended and dissolved metals are being monitored along the Rio Grande and in tributaries. Macroinvertebrate and fish populations are sampled in the same locations. First year observations showed the ecosystem to be relatively resilient, with stable water quality and survival of insects and fish. However, an intense monsoon season this summer is driving extensive sediments into tributaries from steep, severely burned hillslopes. These monsoon events have caused acute and dramatic fish kills, where hundreds of trout were reported killed in one tributary in a single day event. Turbidity was observed as high as 488 NTU in the impacted stream with fish kill, whereas the turbidity was 25 NTU in a neighboring tributary outside of the burn area. Salmonids can be negatively impacted by relatively low turbidity, with prior studies noting that the turbidity threshold for rainbow trout is 70 NTU. Continued monitoring of water quality, macroinvertebrate populations, and fish populations is being undertaken to determine the key drivers of the acute fish kill events. This presentation will highlight the role of burn severity, steepness of slope, hill aspect, and storm intensity on water quality and aquatic response of fire-impacted streams of the Upper Rio Grande.
Aegerter, Sandrine; Jalabert, Bernard; Bobe, Julien
2005-11-01
The mRNA levels of 39 target genes were monitored in unfertilized eggs of 14 rainbow trout sampled the day of ovulation and again 5, 14, and 21 days later. For all 56 collected egg batches, an egg sample was fertilized to estimate egg quality by monitoring embryonic development. Remaining eggs were used for RNA extraction and subsequent real-time PCR analysis. A significant drop of egg quality was observed when eggs were held in the body cavity for 14 or 21 days post-ovulation (dpo). During the same period, eight transcripts (nucleoplasmin or Npm2, ferritin H, tubulin beta, JNK1, cyclin A1, cyclin A2, cathepsin Z, and IGF2) exhibited a differential abundance at one or several collection time(s). Interestingly, we observed higher levels of cyclins A1 and A2 mRNAs in eggs taken 5 days post-ovulation than in eggs taken, from the same females, at the time of ovulation. In addition, seven transcripts exhibited a differential abundance between low quality and high quality eggs. Low quality eggs were characterized by lower levels of Npm2, tubulin beta, and IGF1 transcripts. In contrast, keratins 8 and 18, cathepsin Z, and prostaglandin synthase 2 were more abundant in low quality eggs than in high quality eggs. In this study, we have demonstrated differences in mRNA levels in the rainbow trout egg that are reflective of developmental competence differences induced by post-ovulatory ageing. The putative role of these transcripts in post-ovulatory ageing-induced egg quality defects is discussed with special attention for corresponding cellular functions.
Teacher Quality, Appraisal and Development: The Flaws in the IQMS
ERIC Educational Resources Information Center
De Clerq, Francine
2008-01-01
This article addresses the issue of how to monitor and develop the quality of teaching in schools by identifying the international lessons of teacher appraisal, monitoring and support systems and by interrogating the recently introduced South African Integrated Quality Management System (IQMS). The aim is to show why teacher monitoring and…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
... completeness requirement for one or more quarters during 2009-2011. EPA addressed the missing data of each of...-assured, quality-controlled and certified ambient air monitoring data for the 2008-2010 and 2009-2011...- assured, quality-controlled, and certified monitoring data for the 2007-2009 monitoring period, that the...
The concentration-discharge slope as a tool for water quality management.
Bieroza, M Z; Heathwaite, A L; Bechmann, M; Kyllmar, K; Jordan, P
2018-07-15
Recent technological breakthroughs of optical sensors and analysers have enabled matching the water quality measurement interval to the time scales of stream flow changes and led to an improved understanding of spatially and temporally heterogeneous sources and delivery pathways for many solutes and particulates. This new ability to match the chemograph with the hydrograph has promoted renewed interest in the concentration-discharge (c-q) relationship and its value in characterizing catchment storage, time lags and legacy effects for both weathering products and anthropogenic pollutants. In this paper we evaluated the stream c-q relationships for a number of water quality determinands (phosphorus, suspended sediments, nitrogen) in intensively managed agricultural catchments based on both high-frequency (sub-hourly) and long-term low-frequency (fortnightly-monthly) routine monitoring data. We used resampled high-frequency data to test the uncertainty in water quality parameters (e.g. mean, 95th percentile and load) derived from low-frequency sub-datasets. We showed that the uncertainty in water quality parameters increases with reduced sampling frequency as a function of the c-q slope. We also showed that different sources and delivery pathways control c-q relationship for different solutes and particulates. Secondly, we evaluated the variation in c-q slopes derived from the long-term low-frequency data for different determinands and catchments and showed strong chemostatic behaviour for phosphorus and nitrogen due to saturation and agricultural legacy effects. The c-q slope analysis can provide an effective tool to evaluate the current monitoring networks and the effectiveness of water management interventions. This research highlights how improved understanding of solute and particulate dynamics obtained with optical sensors and analysers can be used to understand patterns in long-term water quality time series, reduce the uncertainty in the monitoring data and to manage eutrophication in agricultural catchments. Copyright © 2018 Elsevier B.V. All rights reserved.
Berendes, Sima; Adeyemi, Olusegun; Oladele, Edward Adekola; Oresanya, Olusola Bukola; Okoh, Festus; Valadez, Joseph J
2012-01-01
Patent medicine vendors (PMV) provide antimalarial treatment and care throughout Sub-Saharan Africa, and can play an important role in the fight against malaria. Their close-to-client infrastructure could enable lifesaving artemisinin-based combination therapy (ACT) to reach patients in time. However, systematic assessments of drug sellers' performance quality are crucial if their role is to be managed within the health system. Lot quality assurance sampling (LQAS) could be an efficient method to monitor and evaluate PMV practice, but has so far never been used for this purpose. In support of the Nigeria Malaria Booster Program we assessed PMV practices in three Senatorial Districts (SDs) of Jigawa, Nigeria. A two-stage LQAS assessed whether at least 80% of PMV stores in SDs used national treatment guidelines. Acceptable sampling errors were set in consultation with government officials (alpha and beta <0.10). The hypergeometric formula determined sample sizes and cut-off values for SDs. A structured assessment tool identified high and low performing SDs for quality of care indicators. Drug vendors performed poorly in all SDs of Jigawa for all indicators. For example, all SDs failed for stocking and selling first-line antimalarials. PMV sold no longer recommended antimalarials, such as Chloroquine, Sulfadoxine-Pyrimethamine and oral Artesunate monotherapy. Most PMV were ignorant of and lacked training about new treatment guidelines that had endorsed ACTs as first-line treatment for uncomplicated malaria. There is urgent need to regularly monitor and improve the availability and quality of malaria treatment provided by medicine sellers in Nigeria; the irrational use of antimalarials in the ACT era revealed in this study bears a high risk of economic loss, death and development of drug resistance. LQAS has been shown to be a suitable method for monitoring malaria-related indicators among PMV, and should be applied in Nigeria and elsewhere to improve service delivery.
Berendes, Sima; Adeyemi, Olusegun; Oladele, Edward Adekola; Oresanya, Olusola Bukola; Okoh, Festus; Valadez, Joseph J.
2012-01-01
Background Patent medicine vendors (PMV) provide antimalarial treatment and care throughout Sub-Saharan Africa, and can play an important role in the fight against malaria. Their close-to-client infrastructure could enable lifesaving artemisinin-based combination therapy (ACT) to reach patients in time. However, systematic assessments of drug sellers’ performance quality are crucial if their role is to be managed within the health system. Lot quality assurance sampling (LQAS) could be an efficient method to monitor and evaluate PMV practice, but has so far never been used for this purpose. Methods In support of the Nigeria Malaria Booster Program we assessed PMV practices in three Senatorial Districts (SDs) of Jigawa, Nigeria. A two-stage LQAS assessed whether at least 80% of PMV stores in SDs used national treatment guidelines. Acceptable sampling errors were set in consultation with government officials (alpha and beta <0.10). The hypergeometric formula determined sample sizes and cut-off values for SDs. A structured assessment tool identified high and low performing SDs for quality of care indicators. Findings Drug vendors performed poorly in all SDs of Jigawa for all indicators. For example, all SDs failed for stocking and selling first-line antimalarials. PMV sold no longer recommended antimalarials, such as Chloroquine, Sulfadoxine-Pyrimethamine and oral Artesunate monotherapy. Most PMV were ignorant of and lacked training about new treatment guidelines that had endorsed ACTs as first-line treatment for uncomplicated malaria. Conclusion There is urgent need to regularly monitor and improve the availability and quality of malaria treatment provided by medicine sellers in Nigeria; the irrational use of antimalarials in the ACT era revealed in this study bears a high risk of economic loss, death and development of drug resistance. LQAS has been shown to be a suitable method for monitoring malaria-related indicators among PMV, and should be applied in Nigeria and elsewhere to improve service delivery. PMID:22984555
Evaluating A Priori Ozone Profile Information Used in TEMPO Tropospheric Ozone Retrievals
NASA Technical Reports Server (NTRS)
Johnson, Matthew S.; Sullivan, John T.; Liu, Xiong; Newchurch, Mike; Kuang, Shi; McGee, Thomas J.; Langford, Andrew O'Neil; Senff, Christoph J.; Leblanc, Thierry; Berkoff, Timothy;
2016-01-01
Ozone (O3) is a greenhouse gas and toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is primarily conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address these limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product. TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME, GOME-2, and OMI. This algorithm uses a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB) O3 climatology). It has been shown that satellite O3 retrievals are sensitive to a priori O3 profiles and covariance matrices. During this work we investigate the climatological data to be used in TEMPO algorithms (TB O3) and simulated data from the NASA GMAO Goddard Earth Observing System (GEOS-5) Forward Processing (FP) near-real-time (NRT) model products. These two data products will be evaluated with ground-based lidar data from the Tropospheric Ozone Lidar Network (TOLNet) at various locations of the US. This study evaluates the TB climatology, GEOS-5 climatology, and 3-hourly GEOS-5 data compared to lower tropospheric observations to demonstrate the accuracy of a priori information to potentially be used in TEMPO O3 algorithms. Here we present our initial analysis and the theoretical impact on TEMPO retrievals in the lower troposphere.
Evaluating a Priori Ozone Profile Information Used in TEMPO Tropospheric Ozone Retrievals
NASA Technical Reports Server (NTRS)
Johnson, Matthew S.; Sullivan, John; Liu, Xiong; Newchurch, Mike; Kuang, Shi; McGee, Thomas; Langford, Andrew; Senff, Chris; Leblanc, Thierry; Berkoff, Timothy;
2016-01-01
Ozone (O3) is a greenhouse gas and toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is primarily conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address these limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product.TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME, GOME-2, and OMI. This algorithm uses a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB) O3 climatology). It has been shown that satellite O3 retrievals are sensitive to a priori O3 profiles and covariance matrices. During this work we investigate the climatological data to be used in TEMPO algorithms (TB O3) and simulated data from the NASA GMAO Goddard Earth Observing System (GEOS-5) Forward Processing (FP) near-real-time (NRT) model products. These two data products will be evaluated with ground-based lidar data from the Tropospheric Ozone Lidar Network (TOLNet) at various locations of the US. This study evaluates the TB climatology, GEOS-5 climatology, and 3-hourly GEOS-5 data compared to lower tropospheric observations to demonstrate the accuracy of a priori information to potentially be used in TEMPO O3 algorithms. Here we present our initial analysis and the theoretical impact on TEMPO retrievals in the lower troposphere.
Ultrasonic Real-Time Quality Monitoring Of Aluminum Spot Weld Process
NASA Astrophysics Data System (ADS)
Perez Regalado, Waldo Josue
The real-time ultrasonic spot weld monitoring system, introduced by our research group, has been designed for the unsupervised quality characterization of the spot welding process. It comprises the ultrasonic transducer (probe) built into one of the welding electrodes and an electronics hardware unit which gathers information from the transducer, performs real-time weld quality characterization and communicates with the robot programmable logic controller (PLC). The system has been fully developed for the inspection of spot welds manufactured in steel alloys, and has been mainly applied in the automotive industry. In recent years, a variety of materials have been introduced to the automotive industry. These include high strength steels, magnesium alloys, and aluminum alloys. Aluminum alloys have been of particular interest due to their high strength-to-weight ratio. Resistance spot welding requirements for aluminum vary greatly from those of steel. Additionally, the oxide film formed on the aluminum surface increases the heat generation between the copper electrodes and the aluminum plates leading to accelerated electrode deterioration. Preliminary studies showed that the real-time quality inspection system was not able to monitor spot welds manufactured with aluminum. The extensive experimental research, finite element modelling of the aluminum welding process and finite difference modeling of the acoustic wave propagation through the aluminum spot welds presented in this dissertation, revealed that the thermodynamics and hence the acoustic wave propagation through an aluminum and a steel spot weld differ significantly. For this reason, the hardware requirements and the algorithms developed to determine the welds quality from the ultrasonic data used on steel, no longer apply on aluminum spot welds. After updating the system and designing the required algorithms, parameters such as liquid nugget penetration and nugget diameter were available in the ultrasonic data acquired during the aluminum welding process. Finally, a fuzzy system was designed to receive these parameters and determine the weld quality.
Evaluating A Priori Ozone Profile Information Used in TEMPO Tropospheric Ozone Retrievals
NASA Astrophysics Data System (ADS)
Johnson, M. S.; Sullivan, J. T.; Liu, X.; Newchurch, M.; Kuang, S.; McGee, T. J.; Langford, A. O.; Senff, C. J.; Leblanc, T.; Berkoff, T.; Gronoff, G.; Chen, G.; Strawbridge, K. B.
2016-12-01
Ozone (O3) is a greenhouse gas and toxic pollutant which plays a major role in air quality. Typically, monitoring of surface air quality and O3 mixing ratios is primarily conducted using in situ measurement networks. This is partially due to high-quality information related to air quality being limited from space-borne platforms due to coarse spatial resolution, limited temporal frequency, and minimal sensitivity to lower tropospheric and surface-level O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite is designed to address these limitations of current space-based platforms and to improve our ability to monitor North American air quality. TEMPO will provide hourly data of total column and vertical profiles of O3 with high spatial resolution to be used as a near-real-time air quality product. TEMPO O3 retrievals will apply the Smithsonian Astrophysical Observatory profile algorithm developed based on work from GOME, GOME-2, and OMI. This algorithm uses a priori O3 profile information from a climatological data-base developed from long-term ozone-sonde measurements (tropopause-based (TB) O3 climatology). It has been shown that satellite O3 retrievals are sensitive to a priori O3 profiles and covariance matrices. During this work we investigate the climatological data to be used in TEMPO algorithms (TB O3) and simulated data from the NASA GMAO Goddard Earth Observing System (GEOS-5) Forward Processing (FP) near-real-time (NRT) model products. These two data products will be evaluated with ground-based lidar data from the Tropospheric Ozone Lidar Network (TOLNet) at various locations of the US. This study evaluates the TB climatology, GEOS-5 climatology, and 3-hourly GEOS-5 data compared to lower tropospheric observations to demonstrate the accuracy of a priori information to potentially be used in TEMPO O3 algorithms. Here we present our initial analysis and the theoretical impact on TEMPO retrievals in the lower troposphere.
NASA Astrophysics Data System (ADS)
Eiriksson, D.; Jones, A. S.; Horsburgh, J. S.; Cox, C.; Dastrup, D.
2017-12-01
Over the past few decades, advances in electronic dataloggers and in situ sensor technology have revolutionized our ability to monitor air, soil, and water to address questions in the environmental sciences. The increased spatial and temporal resolution of in situ data is alluring. However, an often overlooked aspect of these advances are the challenges data managers and technicians face in performing quality control on millions of data points collected every year. While there is general agreement that high quantities of data offer little value unless the data are of high quality, it is commonly understood that despite efforts toward quality assurance, environmental data collection occasionally goes wrong. After identifying erroneous data, data managers and technicians must determine whether to flag, delete, leave unaltered, or retroactively correct suspect data. While individual instrumentation networks often develop their own QA/QC procedures, there is a scarcity of consensus and literature regarding specific solutions and methods for correcting data. This may be because back correction efforts are time consuming, so suspect data are often simply abandoned. Correction techniques are also rarely reported in the literature, likely because corrections are often performed by technicians rather than the researchers who write the scientific papers. Details of correction procedures are often glossed over as a minor component of data collection and processing. To help address this disconnect, we present case studies of quality control challenges, solutions, and lessons learned from a large scale, multi-watershed environmental observatory in Northern Utah that monitors Gradients Along Mountain to Urban Transitions (GAMUT). The GAMUT network consists of over 40 individual climate, water quality, and storm drain monitoring stations that have collected more than 200 million unique data points in four years of operation. In all of our examples, we emphasize that scientists should remain skeptical and seek independent verification of sensor data, even for sensors purchased from trusted manufacturers.
High-frequency remote monitoring of large lakes with MODIS 500 m imagery
McCullough, Ian M.; Loftin, Cynthia S.; Sader, Steven A.
2012-01-01
Satellite-based remote monitoring programs of regional lake water quality largely have relied on Landsat Thematic Mapper (TM) owing to its long image archive, moderate spatial resolution (30 m), and wide sensitivity in the visible portion of the electromagnetic spectrum, despite some notable limitations such as temporal resolution (i.e., 16 days), data pre-processing requirements to improve data quality, and aging satellites. Moderate-Resolution Imaging Spectroradiometer (MODIS) sensors on Aqua/Terra platforms compensate for these shortcomings, although at the expense of spatial resolution. We developed and evaluated a remote monitoring protocol for water clarity of large lakes using MODIS 500 m data and compared MODIS utility to Landsat-based methods. MODIS images captured during May–September 2001, 2004 and 2010 were analyzed with linear regression to identify the relationship between lake water clarity and satellite-measured surface reflectance. Correlations were strong (R² = 0.72–0.94) throughout the study period; however, they were the most consistent in August, reflecting seasonally unstable lake conditions and inter-annual differences in algal productivity during the other months. The utility of MODIS data in remote water quality estimation lies in intra-annual monitoring of lake water clarity in inaccessible, large lakes, whereas Landsat is more appropriate for inter-annual, regional trend analyses of lakes ≥ 8 ha. Model accuracy is improved when ancillary variables are included to reflect seasonal lake dynamics and weather patterns that influence lake clarity. The identification of landscape-scale drivers of regional water quality is a useful way to supplement satellite-based remote monitoring programs relying on spectral data alone.
Assessment of air quality in and around a steel industry with direct reduction iron route.
Jena, Pradip K; Behera, Dillip K; Mishra, C S K; Mohanty, Saswat K
2011-10-01
The coal based Direct Reduced Iron (DRI) route for secondary steel production is now a preferred choice in India. Steel making is invariably associated with emission of air pollutants into the environment. Air quality monitoring was carried out in Winter, Summer and Rainy seasons of 2008 in eight monitoring stations in the work zone and five stations in the residential zone of an Integrated Steel Industry located in Orissa state, India. Four air quality parameters i.e. SPM, RSPM, SO2 and NO2 were monitored. Mean SPM and RSPM values were found to be significantly high (p < 0.01) at stations nearer to source in both work zone and residential zone .The highest average SPM and RSPM values in the work zone recorded were 4869 microg/m3 and 1420 microg/m3 and in the residential zone 294 microg/m3 and 198 microg/m3 respectively. No significant difference in the SO2 and NO2 levels was observed between the work and residential zones. In general, the values of air pollutants were highest in Winter followed by Summer and Rainy season. SPM and RSPM values exceeded the National Air Quality Standards (NAAQS) in both the residential and work zones.
NASA Astrophysics Data System (ADS)
Eiche, Elisabeth; Hochschild, Maren; Haryono, Eko; Neumann, Thomas
2016-09-01
Karst aquifers are important water resources but highly vulnerable due to their heterogeneous and complex characteristics. Various hydrological aspects (recharge, flow behaviour) have to be known in detail to develop a sustainable concept for water collection, distribution and treatment. In the karst area of Gunung Sewu (Java, Indonesia) such a concept was to be implemented within a German-Indonesian joint IWRM project. The basic hydrogeological conditions and water quality aspects were characterized on a regional scale through hydrochemical monitoring of springs, wells, subsurface and surface rivers. More detailed information about the recharge, flow and storage behaviour was obtained from high resolution monitoring of T, EC and discharge in one large underground river system. The water quality is well below any guideline values with regard to inorganic pollutants during dry season. During rainy season, dissolved Al concentrations are frequently above the Indonesian guideline value. Slow matrix flow is the most important recharge component during dry season, thus assuring the year-round water availability in the subsurface karst. During rainy season, quick infiltration of the surface water is a dominant recharge component. Rapid response of discharge, T and EC to heavy rain suggests the presence of point recharge that feeds a highly karstfied conduit system with fast conduit flow and short transit time of water. The strong variations in discharge and hydrochemistry are particularly challenging for technical water usage and treatment facilities. Piston flow is indicated to be the third important flow component and is induced by heavy rainfall.
High-level disinfection of gastrointestinal endoscope reprocessing
Chiu, King-Wah; Lu, Lung-Sheng; Chiou, Shue-Shian
2015-01-01
High level disinfection (HLD) of the gastrointestinal (GI) endoscope is not simply a slogan, but rather is a form of experimental monitoring-based medicine. By definition, GI endoscopy is a semicritical medical device. Hence, such medical devices require major quality assurance for disinfection. And because many of these items are temperature sensitive, low-temperature chemical methods, such as liquid chemical germicide, must be used rather than steam sterilization. In summarizing guidelines for infection prevention and control for GI endoscopy, there are three important steps that must be highlighted: manual washing, HLD with automated endoscope reprocessor, and drying. Strict adherence to current guidelines is required because compared to any other medical device, the GI endoscope is associated with more outbreaks linked to inadequate cleaning or disinfecting during HLD. Both experimental evaluation on the surveillance bacterial cultures and in-use clinical results have shown that, the monitoring of the stringent processes to prevent and control infection is an essential component of the broader strategy to ensure the delivery of safe endoscopy services, because endoscope reprocessing is a multistep procedure involving numerous factors that can interfere with its efficacy. Based on our years of experience in the surveillance of culture monitoring of endoscopic reprocessing, we aim in this study to carefully describe what details require attention in the GI endoscopy disinfection and to share our experience so that patients can be provided with high quality and safe medical practices. Quality management encompasses all aspects of pre- and post-procedural care including the efficiency of the endoscopy unit and reprocessing area, as well as the endoscopic procedure itself. PMID:25699232
Jayakody, Chatura; Hull-Ryde, Emily A
2016-01-01
Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.
Houston, Lauren; Probst, Yasmine; Martin, Allison
2018-05-18
Data audits within clinical settings are extensively used as a major strategy to identify errors, monitor study operations and ensure high-quality data. However, clinical trial guidelines are non-specific in regards to recommended frequency, timing and nature of data audits. The absence of a well-defined data quality definition and method to measure error undermines the reliability of data quality assessment. This review aimed to assess the variability of source data verification (SDV) auditing methods to monitor data quality in a clinical research setting. The scientific databases MEDLINE, Scopus and Science Direct were searched for English language publications, with no date limits applied. Studies were considered if they included data from a clinical trial or clinical research setting and measured and/or reported data quality using a SDV auditing method. In total 15 publications were included. The nature and extent of SDV audit methods in the articles varied widely, depending upon the complexity of the source document, type of study, variables measured (primary or secondary), data audit proportion (3-100%) and collection frequency (6-24 months). Methods for coding, classifying and calculating error were also inconsistent. Transcription errors and inexperienced personnel were the main source of reported error. Repeated SDV audits using the same dataset demonstrated ∼40% improvement in data accuracy and completeness over time. No description was given in regards to what determines poor data quality in clinical trials. A wide range of SDV auditing methods are reported in the published literature though no uniform SDV auditing method could be determined for "best practice" in clinical trials. Published audit methodology articles are warranted for the development of a standardised SDV auditing method to monitor data quality in clinical research settings. Copyright © 2018. Published by Elsevier Inc.
Aisopou, Angeliki; Stoianov, Ivan; Graham, Nigel J D
2012-01-01
Monitoring the quality of drinking water from the treatment plant to the consumers tap is critical to ensure compliance with national standards and/or WHO guideline levels. There are a number of processes and factors affecting the water quality during transmission and distribution which are little understood. A significant obstacle for gaining a detailed knowledge of various physical and chemical processes and the effect of the hydraulic conditions on the water quality deterioration within water supply systems is the lack of reliable and low-cost (both capital and O & M) water quality sensors for continuous monitoring. This paper has two objectives. The first one is to present a detailed evaluation of the performance of a novel in-pipe multi-parameter sensor probe for reagent- and membrane-free continuous water quality monitoring in water supply systems. The second objective is to describe the results from experimental research which was conducted to acquire continuous water quality and high-frequency hydraulic data for the quantitative assessment of the water quality changes occurring under steady and unsteady-state flow conditions. The laboratory and field evaluation of the multi-parameter sensor probe showed that the sensors have a rapid dynamic response, average repeatability and unreliable accuracy. The uncertainties in the sensor data present significant challenges for the analysis and interpretation of the acquired data and their use for water quality modelling, decision support and control in operational systems. Notwithstanding these uncertainties, the unique data sets acquired from transmission and distribution systems demonstrated the deleterious effect of unsteady state flow conditions on various water quality parameters. These studies demonstrate: (i) the significant impact of the unsteady-state hydraulic conditions on the disinfectant residual, turbidity and colour caused by the re-suspension of sediments, scouring of biofilms and tubercles from the pipe and increased mixing, and the need for further experimental research to investigate these interactions; (ii) important advances in sensor technologies which provide unique opportunities to study both the dynamic hydraulic conditions and water quality changes in operational systems. The research in these two areas is critical to better understand and manage the water quality deterioration in ageing water transmission and distribution systems. Copyright © 2011 Elsevier Ltd. All rights reserved.
Baby-MONITOR: A Composite Indicator of NICU Quality
Kowalkowski, Marc A.; Zupancic, John A. F.; Pietz, Kenneth; Richardson, Peter; Draper, David; Hysong, Sylvia J.; Thomas, Eric J.; Petersen, Laura A.; Gould, Jeffrey B.
2014-01-01
BACKGROUND AND OBJECTIVES: NICUs vary in the quality of care delivered to very low birth weight (VLBW) infants. NICU performance on 1 measure of quality only modestly predicts performance on others. Composite measurement of quality of care delivery may provide a more comprehensive assessment of quality. The objective of our study was to develop a robust composite indicator of quality of NICU care provided to VLBW infants that accurately discriminates performance among NICUs. METHODS: We developed a composite indicator, Baby-MONITOR, based on 9 measures of quality chosen by a panel of experts. Measures were standardized, equally weighted, and averaged. We used the California Perinatal Quality Care Collaborative database to perform across-sectional analysis of care given to VLBW infants between 2004 and 2010. Performance on the Baby-MONITOR is not an absolute marker of quality but indicates overall performance relative to that of the other NICUs. We used sensitivity analyses to assess the robustness of the composite indicator, by varying assumptions and methods. RESULTS: Our sample included 9023 VLBW infants in 22 California regional NICUs. We found significant variations within and between NICUs on measured components of the Baby-MONITOR. Risk-adjusted composite scores discriminated performance among this sample of NICUs. Sensitivity analysis that included different approaches to normalization, weighting, and aggregation of individual measures showed the Baby-MONITOR to be robust (r = 0.89–0.99). CONCLUSIONS: The Baby-MONITOR may be a useful tool to comprehensively assess the quality of care delivered by NICUs. PMID:24918221
Eldridge, Sara L. Caldwell; Wherry, Susan A.; Wood, Tamara M.
2014-01-01
Upper Klamath Lake in south-central Oregon has become increasingly eutrophic over the past century and now experiences seasonal cyanobacteria-dominated and potentially toxic phytoplankton blooms. Growth and decline of these blooms create poor water-quality conditions that can be detrimental to fish, including two resident endangered sucker species. Upper Klamath Lake is the primary water supply to agricultural areas within the upper Klamath Basin. Water from the lake is also used to generate power and to enhance and sustain downstream flows in the Klamath River. Water quality in Upper Klamath Lake has been monitored by the Klamath Tribes since the early 1990s and by the U.S. Geological Survey (USGS) since 2002. Management agencies and other stakeholders have determined that a re-evaluation of the goals for water-quality monitoring is warranted to assess whether current data-collection activities will continue to adequately provide data for researchers to address questions of interest and to facilitate future natural resource management decisions. The purpose of this study was to (1) compile an updated list of the goals and objectives for long-term water-quality monitoring in Upper Klamath Lake with input from upper Klamath Basin stakeholders, (2) assess the current water-quality monitoring programs in Upper Klamath Lake to determine whether existing data-collection strategies can fulfill the updated goals and objectives for monitoring, and (3) identify potential modifications to future monitoring plans in accordance with the updated monitoring objectives and improve stakeholder cooperation and data-collection efficiency. Data collected by the Klamath Tribes and the USGS were evaluated to determine whether consistent long-term trends in water-quality variables can be described by the dataset and whether the number and distribution of currently monitored sites captures the full range of environmental conditions and the multi-scale variability of water-quality parameters in the lake. Also, current monitoring strategies were scrutinized for unnecessary redundancy within the overall network.
Achieving excellence in community health centers: implications for health reform.
Gurewich, Deborah; Capitman, John; Sirkin, Jenna; Traje, Diana
2012-02-01
Existing studies tell us little about care quality variation within the community health center (CHC) delivery system. They also tell us little about the organizational conditions associated with CHCs that deliver especially high quality care. The purpose of this study was to examine the operational practices associated with a sample of high performing CHCs. Qualitative case studies of eight CHCs identified as delivering high-quality care relative to other CHCs were used to examine operational practices, including systems to facilitate care access, manage patient care, and monitor performance. Four common themes emerged that may contribute to high performance. At the same time, important differences across health centers were observed, reflecting differences in local environments and CHC capacity. In the development of effective, community-based models of care, adapting care standards to meet the needs of local conditions may be important.
Automated daily quality control analysis for mammography in a multi-unit imaging center.
Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli
2018-01-01
Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.
Quality Assurance in Post-Secondary Education: Some Common Approaches
ERIC Educational Resources Information Center
Law, Dennis Chung Sea
2010-01-01
Purpose: The common approaches to quality assurance (QA), as practiced by most post-secondary education institutions for internal quality monitoring and most QA authorities for external quality monitoring (EQM), have been considered by many researchers as having largely failed to address the essence of educational quality. The purpose of this…
Monitoring surface water quality using social media in the context of citizen science
NASA Astrophysics Data System (ADS)
Zheng, Hang; Hong, Yang; Long, Di; Jing, Hua
2017-02-01
Surface water quality monitoring (SWQM) provides essential information for water environmental protection. However, SWQM is costly and limited in terms of equipment and sites. The global popularity of social media and intelligent mobile devices with GPS and photography functions allows citizens to monitor surface water quality. This study aims to propose a method for SWQM using social media platforms. Specifically, a WeChat-based application platform is built to collect water quality reports from volunteers, which have been proven valuable for water quality monitoring. The methods for data screening and volunteer recruitment are discussed based on the collected reports. The proposed methods provide a framework for collecting water quality data from citizens and offer a primary foundation for big data analysis in future research.
Real-time video quality monitoring
NASA Astrophysics Data System (ADS)
Liu, Tao; Narvekar, Niranjan; Wang, Beibei; Ding, Ran; Zou, Dekun; Cash, Glenn; Bhagavathy, Sitaram; Bloom, Jeffrey
2011-12-01
The ITU-T Recommendation G.1070 is a standardized opinion model for video telephony applications that uses video bitrate, frame rate, and packet-loss rate to measure the video quality. However, this model was original designed as an offline quality planning tool. It cannot be directly used for quality monitoring since the above three input parameters are not readily available within a network or at the decoder. And there is a great room for the performance improvement of this quality metric. In this article, we present a real-time video quality monitoring solution based on this Recommendation. We first propose a scheme to efficiently estimate the three parameters from video bitstreams, so that it can be used as a real-time video quality monitoring tool. Furthermore, an enhanced algorithm based on the G.1070 model that provides more accurate quality prediction is proposed. Finally, to use this metric in real-world applications, we present an example emerging application of real-time quality measurement to the management of transmitted videos, especially those delivered to mobile devices.
Use of crayfishes as ecological indicator of water quality in natural lakes and city water grid
NASA Astrophysics Data System (ADS)
Sapunov, Valentin; Fedotov, Valery
2017-04-01
Crayfishes are organisms having strong demands for water quality. Their different species have different ecological limits. Nobel crayfishes Astacus astacus are organisms with narrow ecological limits need clear water that crayfish Pontastacus leptodactylus. Relation between populations of different crayfishes is criteria of water pollution, level of water bodies eutrofication and ecological pressure. Environmental policy of all countries is directed to water supply by drinking water of high quality and preserving the rivers, lakes and seas, suitable for people and wildlife. However, now freshwater reservoirs and water bodies, as well as including centralized drinking water supply, have been exposed to escalating anthropogenic loading, and risk of sudden emergency pollution. Besides, the problem of providing an ecological safety of the population and prevention of threats of ecological crime and terrorism in a zone of drinking water for many countries. The work is devoted to realization and perspectives of use of the biological early warning stations about changes of quality of surface waters, dangerous to a biota, on the basis of bioelectronic systems as elements of environmental monitoring of water areas. Regular monitoring of crayfish population is a way to follow ecological evolution of ponds. Such a monitoring took place in some lakes of Pskov and Leningrad regions. Ecological characters of crayfishes are appropriate for control of water quality in St. Petersburg and Khabarovsk grids. Fore species were used: Procambarus clarcii, Cherax quadricarinatus, A. astacus and P. leptodactilus. The results of the present work and experiments carried out us to conclude that before assessing any concentration of pollutant on water organisms, it is necessary to investigate not only their development, growth and survival, also their adaptive capacity relative to the variation of environmental parameters. Regular monitoring of heart oscillation was base for control of water pollution in real time. Algorithm and equipment for such a monitoring would be demonstrated.
PHOTOCHEMICAL AIR POLLUTION IN THE NORTH OF PORTUGAL: A HIGH TROPOSHERIC OZONE EPISODE
NASA Astrophysics Data System (ADS)
Monteiro, A.; Carvalho, A.; Tchepel, O.; Ferreira, J.; Martins, H.; Miranda, A.; Borrego, C.; Saavedra, S.; Rodríguez, A.; Souto, J. A.
2009-12-01
Very high concentrations of ozone are continuously measured at the monitoring station at Lamas d’Olo, located at the North of Portugal,. A particular high photochemical episode occurred between 11 and 13 of July 2005, registering ozone hourly maximum values above 350 µg.m-3. This ozone-rich episode is investigated in this paper, in order to identify its origin and formation. Besides the analysis of both meteorological and air quality monitoring datasets, a numerical modelling approach, based on MM5-CAMx system, was used to simulate the dispersion and transport (horizontal and vertical) of the photochemical pollutants and its precursors. A cross spectrum analysis of the meteorological and air quality time series was performed, in the frequency domain, to establish the relationships between ozone data measured at Lamas d’Olo with air quality data from neighbourhood stations and meteorological parameters. Results point out different behaviour/contribution between the analysed sites. Moreover, different contributions of the u and v wind component on the ozone concentration fluctuations were found suggesting the presence a mountain breeze circulation and a north synoptic transport. The preliminary modelling results pointed out that the vertical transport of pollutants are responsible for the measured high concentrations, combined with particular meteorological conditions, related to the planetary boundary layer (PBL) development. The pollutants transported and existent at high vertical levels are captured/trapped when the PBL height reaches its daily maximum, and extremely high ozone ground level concentrations are consequently measured.
4D Near Real-Time Environmental Monitoring Using Highly Temporal LiDAR
NASA Astrophysics Data System (ADS)
Höfle, Bernhard; Canli, Ekrem; Schmitz, Evelyn; Crommelinck, Sophie; Hoffmeister, Dirk; Glade, Thomas
2016-04-01
The last decade has witnessed extensive applications of 3D environmental monitoring with the LiDAR technology, also referred to as laser scanning. Although several automatic methods were developed to extract environmental parameters from LiDAR point clouds, only little research has focused on highly multitemporal near real-time LiDAR (4D-LiDAR) for environmental monitoring. Large potential of applying 4D-LiDAR is given for landscape objects with high and varying rates of change (e.g. plant growth) and also for phenomena with sudden unpredictable changes (e.g. geomorphological processes). In this presentation we will report on the most recent findings of the research projects 4DEMON (http://uni-heidelberg.de/4demon) and NoeSLIDE (https://geomorph.univie.ac.at/forschung/projekte/aktuell/noeslide/). The method development in both projects is based on two real-world use cases: i) Surface parameter derivation of agricultural crops (e.g. crop height) and ii) change detection of landslides. Both projects exploit the "full history" contained in the LiDAR point cloud time series. One crucial initial step of 4D-LiDAR analysis is the co-registration over time, 3D-georeferencing and time-dependent quality assessment of the LiDAR point cloud time series. Due to the high amount of datasets (e.g. one full LiDAR scan per day), the procedure needs to be performed fully automatically. Furthermore, the online near real-time 4D monitoring system requires to set triggers that can detect removal or moving of tie reflectors (used for co-registration) or the scanner itself. This guarantees long-term data acquisition with high quality. We will present results from a georeferencing experiment for 4D-LiDAR monitoring, which performs benchmarking of co-registration, 3D-georeferencing and also fully automatic detection of events (e.g. removal/moving of reflectors or scanner). Secondly, we will show our empirical findings of an ongoing permanent LiDAR observation of a landslide (Gresten, Austria) and an agricultural maize crop stand (Heidelberg, Germany). This research demonstrates the potential and also limitations of fully automated, near real-time 4D LiDAR monitoring in geosciences.
40 CFR 60.2170 - Is there a minimum amount of monitoring data I must obtain?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Is there a minimum amount of monitoring..., 2001 Monitoring § 60.2170 Is there a minimum amount of monitoring data I must obtain? (a) Except for monitor malfunctions, associated repairs, and required quality assurance or quality control activities...
SWEET CubeSat - Water detection and water quality monitoring for the 21st century
NASA Astrophysics Data System (ADS)
Antonini, Kelly; Langer, Martin; Farid, Ahmed; Walter, Ulrich
2017-11-01
Water scarcity and contamination of clean water have been identified as major challenges of the 21st century, in particular for developing countries. According to the International Water Management Institute, about 30% of the world's population does not have reliable access to clean water. Consequently, contaminated water contributes to the death of about 3 million people every year, mostly children. Access to potable water has been proven to boost education, equality and health, reduce hunger, as well as help the economy of the developing world. Currently used in-situ water monitoring techniques are sparse, and often difficult to execute. Space-based instruments will help to overcome these challenges by providing means for water level and water quality monitoring of medium-to-large sweet (fresh) water reservoirs. Data from hyperspectral imaging instruments on past and present governmental missions, such as Envisat and Aqua, has been used for this purpose. However, the high cost of large multi-purpose space vessels, and the lack of dedicated missions limits the continuous monitoring of inland and coastal water quality. The proposed CubeSat mission SWEET (Sweet Water Earth Education Technologies) will try to fill this gap. The SWEET concept is a joint effort between the Technical University of Munich, the German Space Operations Center and the African Steering Committee of the IAF. By using a novel Fabry-Perot interferometer-based hyperspectral imager, the mission will deliver critical data directly to national water resource centers in Africa with an unmatched cost per pixel ratio and high temporal resolution. Additionally, SWEET will incorporate education of students in CubeSat design and water management. Although the aim of the mission is to deliver local water quality and water level data to African countries, further coverage could be achieved with subsequent satellites. Finally, a constellation of SWEET-like CubeSats would extend the coverage to the whole planet, delivering daily data to ensure reliable access to clean water for millions of people worldwide.
77 FR 58301 - Final Requirements-Race to the Top-Early Learning Challenge; Phase 2
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
... career advancement. Core Area B addresses the importance of a high-quality plan for rating and monitoring... adversely affect a sector of the economy, productivity, competition, jobs, the environment, public health or...
Evaluation of Field-deployed Low Cost PM Sensors
Background Particulate matter (PM) is a pollutant of high public interest regulated by national ambient air quality standards (NAAQS) using federal reference method (FRM) and federal equivalent method (FEM) instrumentation identified for environmental monitoring. PM is present i...
INTEGRATING PROBABILISTIC AND FIXED-SITE MONITORING FOR ROBUST WATER QUALITY ASSESSMENTS
Determining the extent of water-quality degradation, controlling nonpoint sources, and defining allowable amounts of contaminants are important water-quality issues defined in the Clean Water Act that require new monitoring data. Probabilistic, randomized stream water-quality mon...
Aircraft and satellite monitoring of water quality in Lake Superior near Duluth
NASA Technical Reports Server (NTRS)
Scherz, J. P.; Sydor, M.; Vandomelen, J. F.
1974-01-01
Satellite images and low altitude aerial photographs often show vivid discolorations in water bodies. Extensive laboratory analysis shows that water reflectance, which causes brightness on aerial images, positively correlates to the water quality parameter of turbidity, which on a particular day correlates to suspended solids. Work with low altitude photography on three overcast days and with ERTS images on five clear days provides positive correlation of image brightness to the high turbidity and solids which are present in Lake Superior near Duluth over 50% of the time. Proper use of aerial images would have shown that an $8,000,000 drinking water intake constructed in the midst of this unpotable, turbid water should have been located 6 miles north in clear, usable water. Noise effects such as skylight reflection, atmospheric effects, and depth penetration also must be understood for operational use of remote sensing for water quality monitoring and are considered in the paper.
Baldwin, K Joanne; Leighton, Nicola A; Kilby, M D; Wyldes, M; Churchill, D; Jones, P W; Johanson, R B
2002-07-01
We set out to measure the standards of care in a regional cohort of women with severe hypertensive illness of pregnancy and to subsequently improve the quality of care using a series of interventions. This was a multi centre cyclical criterion audit involving 21 maternity units in the West Midlands Region. Prospective data collection involved named co-ordinators in each unit using customised proformas. Intervention comprised feedback of baseline results to each hospital, a monitoring chart and eclampsia treatment pack. The first audit period (n = 183) was for a 4-month period between 1/9/96 and 31/12/96 and the second audit period (n = 111) was during the same 4-month period 1 year later. Although compliance with the audit standards set increased in all but one standard, there is clearly a need to make further improvements in the quality of care administered.
The use of a non-nuclear density gauge for monitoring the compaction process of asphalt pavement
NASA Astrophysics Data System (ADS)
Van den bergh, Wim; Vuye, Cedric; Kara, Patricia; Couscheir, Karolien; Blom, Johan; Van Bouwel, Philippe
2017-09-01
The mechanical performance of an asphalt pavement affects its durability - thus carbon footprint. Many parameters contribute to the success of a durable asphalt mix, e.g. material selection, an accurate mix and even the road design in which the asphalt mix quality is quantified. The quality of the asphalt mix, by its mechanical properties, is also related to the compaction degree. However, and specifically for high volume rates, the laying process at the construction site needs an effective method to monitor and adjust immediately the compaction quality before cooling and without damaging the layer, which is now absent. In this paper the use of a non-nuclear density gauge (PQI - Pavement Quality Indicator) is evaluated, based on a site at Brussels Airport. Considering the outcome of the present research, this PQI is advised as a unique tool for continuous density measurements and allow immediate adjustments during compaction, and decreases the number of core drilling for quality control, and as a posteriori asphalt pavement density test where cores are prohibited. The use of PQI could be recommended to be a part of the standard quality control process in the Flemish region.
An Enhanced K-Means Algorithm for Water Quality Analysis of The Haihe River in China
Zou, Hui; Zou, Zhihong; Wang, Xiaojing
2015-01-01
The increase and the complexity of data caused by the uncertain environment is today’s reality. In order to identify water quality effectively and reliably, this paper presents a modified fast clustering algorithm for water quality analysis. The algorithm has adopted a varying weights K-means cluster algorithm to analyze water monitoring data. The varying weights scheme was the best weighting indicator selected by a modified indicator weight self-adjustment algorithm based on K-means, which is named MIWAS-K-means. The new clustering algorithm avoids the margin of the iteration not being calculated in some cases. With the fast clustering analysis, we can identify the quality of water samples. The algorithm is applied in water quality analysis of the Haihe River (China) data obtained by the monitoring network over a period of eight years (2006–2013) with four indicators at seven different sites (2078 samples). Both the theoretical and simulated results demonstrate that the algorithm is efficient and reliable for water quality analysis of the Haihe River. In addition, the algorithm can be applied to more complex data matrices with high dimensionality. PMID:26569283
Establishment and evaluation of a theater influenza monitoring platform.
Wang, Jian; Yang, Hui-Suo; Deng, Bing; Shi, Meng-Jing; Li, Xiang-Da; Nian, Qing-Gong; Song, Wen-Jing; Bing, Feng; Li, Qing-Feng
2017-11-20
Influenza is an acute respiratory infectious disease with a high incidence rate in the Chinese army, which directly disturbs military training and affects soldiers' health. Influenza surveillance systems are widely used around the world and play an important role in influenza epidemic prevention and control. As a theater centers for disease prevention and control, we established an influenza monitoring platform (IMP) in 2014 to strengthen the monitoring of influenza-like illness and influenza virus infection. In this study, we introduced the constitution, influenza virus detection, and quality control for an IMP. The monitoring effect was also evaluated by comparing the monitoring data with data from national influenza surveillance systems. The experiences and problems associated with the platform also were summarized. A theater IMP was established based on 3 levels of medical units, including monitoring sites, testing laboratories and a checking laboratory. A series of measures were taken to guarantee the quality of monitoring, such as technical training, a unified process, sufficient supervision and timely communication. The platform has run smoothly for 3 monitoring years to date. In the 2014-2015 and 2016-2017 monitoring years, sample amount coincided with that obtained from the National Influenza Surveillance program. In the 2015-2016 monitoring year, due to the strict prevention and control measures, an influenza epidemic peak was avoided in monitoring units, and the monitoring data did not coincide with that of the National Influenza Surveillance program. Several problems, including insufficient attention, unreasonable administrative intervention or subordination relationships, and the necessity of detection in monitoring sites were still observed. A theater IMP was established rationally and played a deserved role in the prevention and control of influenza. However, several problems remain to be solved.
Possibilities in optical monitoring of laser welding process
NASA Astrophysics Data System (ADS)
Horník, Petr; Mrňa, Libor; Pavelka, Jan
2016-11-01
Laser welding is a modern, widely used but still not really common method of welding. With increasing demands on the quality of the welds, it is usual to apply automated machine welding and with on-line monitoring of the welding process. The resulting quality of the weld is largely affected by the behavior of keyhole. However, its direct observation during the welding process is practically impossible and it is necessary to use indirect methods. At ISI we have developed optical methods of monitoring the process. Most advanced is an analysis of radiation of laser-induced plasma plume forming in the keyhole where changes in the frequency of the plasma bursts are monitored and evaluated using Fourier and autocorrelation analysis. Another solution, robust and suitable for industry, is based on the observation of the keyhole inlet opening through a coaxial camera mounted in the welding head and the subsequent image processing by computer vision methods. A high-speed camera is used to understand the dynamics of the plasma plume. Through optical spectroscopy of the plume, we can study the excitation of elements in a material. It is also beneficial to monitor the gas flow of shielding gas using schlieren method.
NASA Astrophysics Data System (ADS)
Walker, David; Forsythe, Nathan; Parkin, Geoff; Gowing, John
2016-07-01
This study shows how community-based hydrometeorological monitoring programmes can provide reliable high-quality measurements comparable to formal observations. Time series of daily rainfall, river stage and groundwater levels obtained by a local community in Dangila woreda, northwest Ethiopia, have passed accepted quality control standards and have been statistically validated against formal sources. In a region of low-density and declining formal hydrometeorological monitoring networks, a situation shared by much of the developing world, community-based monitoring can fill the observational void providing improved spatial and temporal characterisation of rainfall, river flow and groundwater levels. Such time series data are invaluable in water resource assessment and management, particularly where, as shown here, gridded rainfall datasets provide gross under or over estimations of rainfall and where groundwater level data are non-existent. Discussions with the local community during workshops held at the setup of the monitoring programme and since have demonstrated that the community have become engaged in the project and have benefited from a greater hydrological knowledge and sense of ownership of their resources. This increased understanding and empowerment is at the relevant scale required for effective community-based participatory management of shallow groundwater and river catchments.
Neural manufacturing: a novel concept for processing modeling, monitoring, and control
NASA Astrophysics Data System (ADS)
Fu, Chi Y.; Petrich, Loren; Law, Benjamin
1995-09-01
Semiconductor fabrication lines have become extremely costly, and achieving a good return from such a high capital investment requires efficient utilization of these expensive facilities. It is highly desirable to shorten processing development time, increase fabrication yield, enhance flexibility, improve quality, and minimize downtime. We propose that these ends can be achieved by applying recent advances in the areas of artificial neural networks, fuzzy logic, machine learning, and genetic algorithms. We use the term neural manufacturing to describe such applications. This paper describes our use of artificial neural networks to improve the monitoring and control of semiconductor process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sellman, Jake; Dykstra, Tim
The Duck Valley Reservoirs Fish Stocking and Operations and Maintenance (DV Fisheries) project is an ongoing resident fish program designed to enhance both subsistence fishing, educational opportunities for Tribal members of the Shoshone-Paiute Tribes, and recreational fishing facilities for non-Tribal members. In addition to stocking rainbow trout (Oncorhynchus mykiss) in Mountain View, Lake Billy Shaw, and Sheep Creek Reservoirs, the program also intends to afford and maintain healthy aquatic conditions for fish growth and survival, to provide superior facilities with wilderness qualities to attract non-Tribal angler use, and to offer clear, consistent communication with the Tribal community about this projectmore » as well as outreach and education within the region and the local community. Tasks for this performance period are divided into operations and maintenance plus monitoring and evaluation. Operation and maintenance of the three reservoirs include fences, roads, dams and all reservoir structures, feeder canals, water troughs and stock ponds, educational signs, vehicles and equipment, and outhouses. Monitoring and evaluation activities included creel, gillnet, wildlife, and bird surveys, water quality and reservoir structures monitoring, native vegetation planting, photo point documentation, control of encroaching exotic vegetation, and community outreach and education. The three reservoirs are monitored in terms of water quality and fishery success. Sheep Creek Reservoir was the least productive as a result of high turbidity levels and constraining water quality parameters. Lake Billy Shaw trout were in poorer condition than in previous years potentially as a result of water quality or other factors. Mountain View Reservoir trout exhibit the best health of the three reservoirs and was the only reservoir to receive constant flows of water.« less
Singh, Ravendra; Román-Ospino, Andrés D; Romañach, Rodolfo J; Ierapetritou, Marianthi; Ramachandran, Rohit
2015-11-10
The pharmaceutical industry is strictly regulated, where precise and accurate control of the end product quality is necessary to ensure the effectiveness of the drug products. For such control, the process and raw materials variability ideally need to be fed-forward in real time into an automatic control system so that a proactive action can be taken before it can affect the end product quality. Variations in raw material properties (e.g., particle size), feeder hopper level, amount of lubrication, milling and blending action, applied shear in different processing stages can affect the blend density significantly and thereby tablet weight, hardness and dissolution. Therefore, real time monitoring of powder bulk density variability and its incorporation into the automatic control system so that its effect can be mitigated proactively and efficiently is highly desired. However, real time monitoring of powder bulk density is still a challenging task because of different level of complexities. In this work, powder bulk density which has a significant effect on the critical quality attributes (CQA's) has been monitored in real time in a pilot-plant facility, using a NIR sensor. The sensitivity of the powder bulk density on critical process parameters (CPP's) and CQA's has been analyzed and thereby feed-forward controller has been designed. The measured signal can be used for feed-forward control so that the corrective actions on the density variations can be taken before they can influence the product quality. The coupled feed-forward/feed-back control system demonstrates improved control performance and improvements in the final product quality in the presence of process and raw material variations. Copyright © 2015 Elsevier B.V. All rights reserved.
Large Scale Application of Vibration Sensors for Fan Monitoring at Commercial Layer Hen Houses
Chen, Yan; Ni, Ji-Qin; Diehl, Claude A.; Heber, Albert J.; Bogan, Bill W.; Chai, Li-Long
2010-01-01
Continuously monitoring the operation of each individual fan can significantly improve the measurement quality of aerial pollutant emissions from animal buildings that have a large number of fans. To monitor the fan operation by detecting the fan vibration is a relatively new technique. A low-cost electronic vibration sensor was developed and commercialized. However, its large scale application has not yet been evaluated. This paper presents long-term performance results of this vibration sensor at two large commercial layer houses. Vibration sensors were installed on 164 fans of 130 cm diameter to continuously monitor the fan on/off status for two years. The performance of the vibration sensors was compared with fan rotational speed (FRS) sensors. The vibration sensors exhibited quick response and high sensitivity to fan operations and therefore satisfied the general requirements of air quality research. The study proved that detecting fan vibration was an effective method to monitor the on/off status of a large number of single-speed fans. The vibration sensor itself was $2 more expensive than a magnetic proximity FRS sensor but the overall cost including installation and data acquisition hardware was $77 less expensive than the FRS sensor. A total of nine vibration sensors failed during the study and the failure rate was related to the batches of product. A few sensors also exhibited unsteady sensitivity. As a new product, the quality of the sensor should be improved to make it more reliable and acceptable. PMID:22163544
A data management and publication workflow for a large-scale, heterogeneous sensor network.
Jones, Amber Spackman; Horsburgh, Jeffery S; Reeder, Stephanie L; Ramírez, Maurier; Caraballo, Juan
2015-06-01
It is common for hydrology researchers to collect data using in situ sensors at high frequencies, for extended durations, and with spatial distributions that produce data volumes requiring infrastructure for data storage, management, and sharing. The availability and utility of these data in addressing scientific questions related to water availability, water quality, and natural disasters relies on effective cyberinfrastructure that facilitates transformation of raw sensor data into usable data products. It also depends on the ability of researchers to share and access the data in useable formats. In this paper, we describe a data management and publication workflow and software tools for research groups and sites conducting long-term monitoring using in situ sensors. Functionality includes the ability to track monitoring equipment inventory and events related to field maintenance. Linking this information to the observational data is imperative in ensuring the quality of sensor-based data products. We present these tools in the context of a case study for the innovative Urban Transitions and Aridregion Hydrosustainability (iUTAH) sensor network. The iUTAH monitoring network includes sensors at aquatic and terrestrial sites for continuous monitoring of common meteorological variables, snow accumulation and melt, soil moisture, surface water flow, and surface water quality. We present the overall workflow we have developed for effectively transferring data from field monitoring sites to ultimate end-users and describe the software tools we have deployed for storing, managing, and sharing the sensor data. These tools are all open source and available for others to use.
NASA Astrophysics Data System (ADS)
Tavera, E. M.; Rodriguez-Espinosa, P. F.; Morales-Garcia, S. S.; Muñoz-Sevilla, N. P.
2014-12-01
The Zahuapan and Atoyac rivers were characterized in the Upper Atoyac through the integration of physical and chemical parameters (environmental firm) determining the behavior and function of the basin as a tool for measuring and monitoring the quality and management of water resources of the water in one of the most polluted rivers in Mexico. For the determination of the environmental signature proceeded to characterize the water through 11 physicochemical parameters: temperature (T), potential hydrogen (pH), dissolved oxygen (DO), spectral absorption coefficient (SAC), the reduction of oxide potential (ORP), turbidity (Turb), conductivity (l), biochemical oxygen demand in 5 days (BOD5), chemical oxygen demand (COD), total suspended solids (TSS) and total dissolved solids (TDS ), which were evaluated in 49 sites in the dry season, 47 for the rainy season and 23 for the winter season in the basin and Atoyac Zahuapan Alto Atoyac, Puebla-Tlaxcala, Mexico river; finding a mathematical algorithm to assimilate and better represent the information obtained. The algorithm allows us to estimate correlation greater than 0.85. The results allow us to propose the algorithm used in the monitoring stations for purposes of processing information assimilated form.This measurement and monitoring of water quality supports the project, the monitoring network in real time and the actions to clean up Atoyac River, in the urban area of the city of Puebla.
NASA Astrophysics Data System (ADS)
KIM, M.; Kim, J.; Baek, J.; Kim, C.; Shin, H.
2013-12-01
It has being happened as flush flood or red/green tide in various natural phenomena due to climate change and indiscreet development of river or land. Especially, water being very important to man should be protected and managed from water quality pollution, and in water resources management, real-time watershed monitoring system is being operated with the purpose of keeping watch and managing on rivers. It is especially important to monitor and forecast water quality in watershed. A study area selected Nak_K as one site among TMDL unit watershed in Nakdong River. This study is to develop a water quality forecasting model connected with making full use of observed data of 8 day interval from Nakdong River Environment Research Center. When forecasting models for each of the BOD, DO, COD, and chlorophyll-a are established considering correlation of various water quality factors, it is needed to select water quality factors showing highly considerable correlation with each water quality factor which is BOD, DO, COD, and chlorophyll-a. For analyzing the correlation of the factors (reservoir discharge, precipitation, air temperature, DO, BOD, COD, Tw, TN, TP, chlorophyll-a), in this study, self-organizing map was used and cross correlation analysis method was also used for comparing results drawn. Based on the results, each forecasting model for BOD, DO, COD, and chlorophyll-a was developed during the short period as 8, 16, 24, 32 days at 8 day interval. The each forecasting model is based on neural network with back propagation algorithm. That is, the study is connected with self-organizing map for analyzing correlation among various factors and neural network model for forecasting of water quality. It is considerably effective to manage the water quality in plenty of rivers, then, it specially is possible to monitor a variety of accidents in water quality. It will work well to protect water quality and to prevent destruction of the environment becoming more and more serious before occurring.
Evaluation of a GEM and CAT-based detector for radiation therapy beam monitoring
NASA Astrophysics Data System (ADS)
Brahme, A.; Danielsson, M.; Iacobaeus, C.; Ostling, J.; Peskov, V.; Wallmark, M.
2000-11-01
We are developing a radiation therapy beam monitor for the Karolinska Institute. This monitor will consist of two consecutive detectors confined in one gas chamber: a "keV-photon detector", which will allow diagnostic quality visualization of the patient, and a "MeV-photon detector", that will measure the absolute intensity of the therapy beam and its position with respect to the patient. Both detectors are based on highly radiation resistant gas and solid photon to electron converters, combined with GEMs and a CAT as amplification structures. We have performed systematic studies of the high-rate characteristics of the GEM and the CAT, as well as tested the electron transfer through these electron multipliers and various types of converters. The tests show that the GEM and the CAT satisfy all requirements for the beam monitoring system. As a result of these studies we successfully developed and tested a full section of the beam monitor equipped with a MeV-photon converter placed between the GEM and the CAT.
Using an electronic activity monitor system as an intervention modality: A systematic review.
Lewis, Zakkoyya H; Lyons, Elizabeth J; Jarvis, Jessica M; Baillargeon, Jacques
2015-06-24
Obesity is a growing global health concern that may lead to cardiovascular disease, type II diabetes, and cancer. Several systematic reviews have shown that technology is successful in combating obesity through increased physical activity, but there is no known review on interventions that use an electronic activity monitor system (EAMS). EAMSs are defined as a wearable device that objectively measures lifestyle physical activity and can provide feedback, beyond the display of basic activity count information, via the monitor display or through a partnering application to elicit continual self-monitoring of activity behavior. These devices improve upon standard pedometers because they have the ability to provide visual feedback on activity progression, verbal encouragement, and social comparison. This systematic review aimed to synthesize the efficacy and feasibility results of EAMSs within published physical activity interventions. Electronic databases and journal references were searched for relevant articles. Data sources included CINAHL, Cochrane CENTRAL, Medline Ovid, PsycINFO, and clinicaltrials.gov. Out of the 1,574 retrieved, 11 articles met the inclusion criteria. These articles were reviewed for quality and content based on a risk of bias tool and intervention components. Most articles were determined to be of medium quality while two were of low quality, and one of high quality. Significant pre-post improvements in the EAMS group were found in five of nine studies for physical activity and in four of five studies for weight. One found a significant increase in physical activity and two studies found significant weight loss in the intervention group compared with the comparator group. The EAMS interventions appear to be feasible with most studies reporting continual wear of the device during waking hours and a higher retention rate of participants in the EAMS groups. These studies provide preliminary evidence suggesting that EAMS can increase physical activity and decrease weight significantly, but their efficacy compared to other interventions has not yet been demonstrated. More high-quality randomized controlled trials are needed to evaluate the overall effect of EAMS, examine which EAMS features are most effective, and determine which populations are most receptive to an EAMS.
NASA Astrophysics Data System (ADS)
Wade, A. J.; Palmer-Felgate, E. J.; Halliday, S. J.; Skeffington, R. A.; Loewenthal, M.; Jarvie, H. P.; Bowes, M. J.; Greenway, G. M.; Haswell, S. J.; Bell, I. M.; Joly, E.; Fallatah, A.; Neal, C.; Williams, R. J.; Gozzard, E.; Newman, J. R.
2012-05-01
This paper introduces new insights into the hydrochemical functioning of lowland river-systems using field-based spectrophotometric and electrode technologies. The streamwater concentrations of nitrogen species and phosphorus fractions were measured at hourly intervals on a continuous basis at two contrasting sites on tributaries of the River Thames, one draining a rural catchment, the River Enborne, and one draining a more urban system, The Cut. The measurements complement those from an existing network of multi-parameter water quality sondes maintained across the Thames catchment and weekly monitoring based on grab samples. The results of the sub-daily monitoring show that streamwater phosphorus concentrations display highly complex, seemingly chaotic, dynamics under storm conditions dependent on the antecedent catchment wetness, and that diurnal phosphorus and nitrogen cycles occur under low flow conditions. The diurnal patterns highlight the dominance of sewage inputs in controlling the streamwater phosphorus and nitrogen concentrations at low flows, even at a distance of 7 km from the nearest sewage works in the rural, River Enborne, and that the time of sample collection is important when judging water quality against ecological thresholds or standards. An exhaustion of the supply of phosphorus from diffuse and septic tank sources during storm events was evident and load estimation was not improved by sub-daily monitoring beyond that achieved by daily sampling because of the eventual reduction in the phosphorus mass entering the stream during events. The dominance of respiration over photosynthesis in The Cut indicated a prevalence of heterotrophic algae, and the seasonal patterns in respiration and photosynthesis corresponded with those of temperature and light in this nutrient over-enriched stream. These results highlight the utility of sub-daily water quality measurements but the deployment of modified wet-chemistry technologies into the field was limited by mains electricity availability. A new approach is therefore needed to allow measurement of a wide range of analytes at a broader range of locations for the development of water quality web-sensor networks. The development and field deployment of a miniaturised "lab-on-a-chip" ion chromatograph is proposed and justified.
Near-infrared Spectroscopy in the Brewing Industry.
Sileoni, Valeria; Marconi, Ombretta; Perretti, Giuseppe
2015-01-01
This article offers an exhaustive description of the use of Near-Infrared (NIR) Spectroscopy in the brewing industry. This technique is widely used for quality control testing of raw materials, intermediates, and finished products, as well as process monitoring during malting and brewing. In particular, most of the reviewed works focus on the assessment of barley properties, aimed at quickly selecting the best barley varieties in order to produce a high-quality malt leading to high-quality beer. Various works concerning the use of NIR in the evaluation of raw materials, such as barley, malt, hop, and yeast, are also summarized here. The implementation of NIR sensors for the control of malting and brewing processes is also highlighted, as well as the use of NIR for quality assessment of the final product.
ERIC Educational Resources Information Center
Hotaling, Liesl; Lowes, Susan; Stolkin, Rustam; Lin, Peiyi; Bonner, James; Kirkey, William; Ojo, Temitope
2012-01-01
This paper describes the structure and impact of an NSF-funded ITEST project designed to enrich science, technology, engineering, and mathematics (STEM) education using educational modules that teach students to construct, program, and test a series of sensors used to monitor water quality. During the two years of the SENSE IT project, over 30…
NASA Technical Reports Server (NTRS)
Tabib-Azar, M.; Akinwande, D.; Ponchak, George E.; LeClair, S. R.
1999-01-01
In this article we report the design, fabrication, and characterization of very high quality factor 10 GHz microstrip resonators on high-resistivity (high-rho) silicon substrates. Our experiments show that an external quality factor of over 13 000 can be achieved on microstripline resonators on high-rho silicon substrates. Such a high Q factor enables integration of arrays of previously reported evanescent microwave probe (EMP) on silicon cantilever beams. We also demonstrate that electron-hole pair recombination and generation lifetimes of silicon can be conveniently measured by illuminating the resonator using a pulsed light. Alternatively, the EMP was also used to nondestructively monitor excess carrier generation and recombination process in a semiconductor placed near the two-dimensional resonator.
The role of Environmental Health System air quality monitors in Space Station Contingency Operations
NASA Technical Reports Server (NTRS)
Limero, Thomas F.; Wilson, Steve; Perlot, Susan; James, John
1992-01-01
This paper describes the Space Station Freedom (SSF) Environmental Health System's air-quality monitoring strategy and instrumentation. A two-tier system has been developed, consisting of first-alert instruments that warn the crew of airborne contamination and a volatile organic analyzer that can identify volatile organic contaminants in near-real time. The strategy for air quality monitoring on SSF is designed to provide early detection so that the contamination can be confined to one module and so that crew health and safety can be protected throughout the contingency event. The use of air-quality monitors in fixed and portable modes will be presented as a means of following the progress of decontamination efforts and ensuring acceptable air quality in a module after an incident. The technology of each instrument will be reviewed briefly; the main focus of this paper, however, will be the use of air-quality monitors before, during, and after contingency incidents.
Workaholism and sleep quality among Japanese employees: a prospective cohort study.
Kubota, Kazumi; Shimazu, Akihito; Kawakami, Norito; Takahashi, Masaya
2014-02-01
This study focused on workaholism as a personal attitude toward work and examined its effects on sleep quality among Japanese employees from various occupations. The present study aimed to demonstrate the prospective association of workaholism (i.e., working excessively hard in a compulsive fashion) with sleep quality among Japanese employees. A Web-based prospective survey was conducted in October 2010 and May 2011 among registered monitors of a survey company. The questionnaire included workaholism, sleep quality, job characteristics, and demographics. Overall, 13,564 monitors were randomly invited to complete the first wave of the survey. The first 2,520 respondents were included in this study. The respondents who completed the first wave were invited to complete the second wave of the survey; 2,061 answered. A total of 364 respondents who changed their working conditions during the follow-up period were excluded. In addition, due to missing values, data from 14 respondents were excluded. Thus, the responses from 1,683 respondents were included in the analysis (859 males and 824 females). An analysis of covariance (ANCOVA) was conducted to compare adjusted sleep quality at follow-up among workaholism groups (low, middle, and high). To conduct the ANCOVA, we adjusted for demographics, sleep quality at baseline, and job characteristics. The high-workaholic group had significantly longer sleep latency at follow-up compared with the low- and middle-workaholic groups after adjusting for demographics, sleep latency at baseline, and job characteristics. In addition, the high-workaholic group demonstrated significantly higher levels of daytime dysfunction compared with the low-workaholic group. However, no significant differences were found among workaholic groups in terms of overall sleep quality, sleep duration, habitual sleep efficiency, sleep disturbance, and use of sleep medication. Workaholism was associated with poor sleep quality at the 7-month follow-up in terms of sleep latency and daytime dysfunction.
Association of Maltreatment With High-Risk Internet Behaviors and Offline Encounters
Shenk, Chad E.; Barnes, Jaclyn E.; Haralson, Katherine J.
2013-01-01
OBJECTIVE: High-risk Internet behaviors, including viewing sexually explicit content, provocative social networking profiles, and entertaining online sexual solicitations, were examined in a sample of maltreated and nonmaltreated adolescent girls aged 14 to 17 years. The impact of Internet behaviors on subsequent offline meetings was observed over 12 to 16 months. This study tested 2 main hypotheses: (1) maltreatment would be a unique contributor to high-risk Internet behaviors and (2) high-quality parenting would dampen adolescents’ propensity to engage in high-risk Internet behaviors and to participate in offline meetings. METHODS: Online and offline behaviors and parenting quality were gleaned from 251 adolescent girls, 130 of whom experienced substantiated maltreatment and 121 of whom were demographically matched comparison girls. Parents reported on adolescent behaviors and on the level of Internet monitoring in the home. Social networking profiles were objectively coded for provocative self-presentations. Offline meetings with persons first met online were assessed 12 to 16 months later. RESULTS: Thirty percent of adolescents reported having offline meetings. Maltreatment, adolescent behavioral problems, and low cognitive ability were uniquely associated with high-risk Internet behaviors. Exposure to sexual content, creating high-risk social networking profiles, and receiving online sexual solicitations were independent predictors of subsequent offline meetings. High-quality parenting and parental monitoring moderated the associations between adolescent risk factors and Internet behaviors, whereas use of parental control software did not. CONCLUSIONS: Treatment modalities for maltreated adolescents should be enhanced to include Internet safety literacy. Adolescents and parents should be aware of how online self-presentations and other Internet behaviors can increase vulnerability for Internet-initiated victimization. PMID:23319522
Association of maltreatment with high-risk internet behaviors and offline encounters.
Noll, Jennie G; Shenk, Chad E; Barnes, Jaclyn E; Haralson, Katherine J
2013-02-01
High-risk Internet behaviors, including viewing sexually explicit content, provocative social networking profiles, and entertaining online sexual solicitations, were examined in a sample of maltreated and nonmaltreated adolescent girls aged 14 to 17 years. The impact of Internet behaviors on subsequent offline meetings was observed over 12 to 16 months. This study tested 2 main hypotheses: (1) maltreatment would be a unique contributor to high-risk Internet behaviors and (2) high-quality parenting would dampen adolescents' propensity to engage in high-risk Internet behaviors and to participate in offline meetings. Online and offline behaviors and parenting quality were gleaned from 251 adolescent girls, 130 of whom experienced substantiated maltreatment and 121 of whom were demographically matched comparison girls. Parents reported on adolescent behaviors and on the level of Internet monitoring in the home. Social networking profiles were objectively coded for provocative self-presentations. Offline meetings with persons first met online were assessed 12 to 16 months later. Thirty percent of adolescents reported having offline meetings. Maltreatment, adolescent behavioral problems, and low cognitive ability were uniquely associated with high-risk Internet behaviors. Exposure to sexual content, creating high-risk social networking profiles, and receiving online sexual solicitations were independent predictors of subsequent offline meetings. High-quality parenting and parental monitoring moderated the associations between adolescent risk factors and Internet behaviors, whereas use of parental control software did not. Treatment modalities for maltreated adolescents should be enhanced to include Internet safety literacy. Adolescents and parents should be aware of how online self-presentations and other Internet behaviors can increase vulnerability for Internet-initiated victimization.
Baron, Ronan; Saffell, John
2017-11-22
This review examines the use of amperometric electrochemical gas sensors for monitoring inorganic gases that affect urban air quality. First, we consider amperometric gas sensor technology including its development toward specifically designed air quality sensors. We then review recent academic and research organizations' studies where this technology has been trialed for air quality monitoring applications: early studies showed the potential of electrochemical gas sensors when colocated with reference Air Quality Monitoring (AQM) stations. Spatially dense networks with fast temporal resolution provide information not available from sparse AQMs with longer recording intervals. We review how this technology is being offered as commercial urban air quality networks and consider the remaining challenges. Sensors must be sensitive, selective, and stable; air quality monitors/nodes must be electronically and mechanically well designed. Data correction is required and models with differing levels of sophistication are being designed. Data analysis and validation is possibly the biggest remaining hurdle needed to deliver reliable concentration readings. Finally, this review also considers the roles of companies, urban infrastructure requirements, and public research in the development of this technology.
Benjamin, David M; Pendrak, Robert F
2003-07-01
Clinical pharmacologists are all dedicated to improving the use of medications and decreasing medication errors and adverse drug reactions. However, quality improvement requires that some significant parameters of quality be categorized, measured, and tracked to provide benchmarks to which future data (performance) can be compared. One of the best ways to accumulate data on medication errors and adverse drug reactions is to look at medical malpractice data compiled by the insurance industry. Using data from PHICO insurance company, PHICO's Closed Claims Data, and PHICO's Event Reporting Trending System (PERTS), this article examines the significance and trends of the claims and events reported between 1996 and 1998. Those who misread history are doomed to repeat the mistakes of the past. From a quality improvement perspective, the categorization of the claims and events is useful for reengineering integrated medication delivery, particularly in a hospital setting, and for redesigning drug administration protocols on low therapeutic index medications and "high-risk" drugs. Demonstrable evidence of quality improvement is being required by state laws and by accreditation agencies. The state of Florida requires that quality improvement data be posted quarterly on the Web sites of the health care facilities. Other states have followed suit. The insurance industry is concerned with costs, and medication errors cost money. Even excluding costs of litigation, an adverse drug reaction may cost up to $2500 in hospital resources, and a preventable medication error may cost almost $4700. To monitor costs and assess risk, insurance companies want to know what errors are made and where the system has broken down, permitting the error to occur. Recording and evaluating reliable data on adverse drug events is the first step in improving the quality of pharmacotherapy and increasing patient safety. Cost savings and quality improvement evolve on parallel paths. The PHICO data provide an excellent opportunity to review information that typically would not be in the public domain. The events captured by PHICO are similar to the errors and "high-risk" drugs described in the literature, the U.S. Pharmacopeia's MedMARx Reporting System, and the Sentinel Event reporting system maintained by the Joint Commission for the Accreditation of Healthcare Organizations. The information in this report serves to alert clinicians to the possibility of adverse events when treating patients with the reported drugs, thus allowing for greater care in their use and closer monitoring. Moreover, when using high-risk drugs, patients should be well informed of known risks, dosage should be titrated slowly, and therapeutic drug monitoring and laboratory monitoring should be employed to optimize therapy and minimize adverse effects.
Code of Federal Regulations, 2014 CFR
2014-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Code of Federal Regulations, 2011 CFR
2011-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...
Code of Federal Regulations, 2013 CFR
2013-07-01
... QUALITY SURVEILLANCE General Provisions § 58.2 Purpose. (a) This part contains requirements for measuring ambient air quality and for reporting ambient air quality data and related information. The monitoring criteria pertain to the following areas: (1) Quality assurance procedures for monitor operation and data...