Sample records for high quality repeatable

  1. Impact of image quality on OCT angiography based quantitative measurements.

    PubMed

    Al-Sheikh, Mayss; Ghasemi Falavarjani, Khalil; Akil, Handan; Sadda, SriniVas R

    2017-01-01

    To study the impact of image quality on quantitative measurements and the frequency of segmentation error with optical coherence tomography angiography (OCTA). Seventeen eyes of 10 healthy individuals were included in this study. OCTA was performed using a swept-source device (Triton, Topcon). Each subject underwent three scanning sessions 1-2 min apart; the first two scans were obtained under standard conditions and for the third session, the image quality index was reduced using application of a topical ointment. En face OCTA images of the retinal vasculature were generated using the default segmentation for the superficial and deep retinal layer (SRL, DRL). Intraclass correlation coefficient (ICC) was used as a measure for repeatability. The frequency of segmentation error, motion artifact, banding artifact and projection artifact was also compared among the three sessions. The frequency of segmentation error, and motion artifact was statistically similar between high and low image quality sessions (P = 0.707, and P = 1 respectively). However, the frequency of projection and banding artifact was higher with a lower image quality. The vessel density in the SRL was highly repeatable in the high image quality sessions (ICC = 0.8), however, the repeatability was low, comparing the high and low image quality measurements (ICC = 0.3). In the DRL, the repeatability of the vessel density measurements was fair in the high quality sessions (ICC = 0.6 and ICC = 0.5, with and without automatic artifact removal, respectively) and poor comparing high and low image quality sessions (ICC = 0.3 and ICC = 0.06, with and without automatic artifact removal, respectively). The frequency of artifacts is higher and the repeatability of the measurements is lower with lower image quality. The impact of image quality index should be always considered in OCTA based quantitative measurements.

  2. Interventions for Preventing Unintended, Rapid Repeat Pregnancy Among Adolescents: A Review of the Evidence and Lessons From High-Quality Evaluations

    PubMed Central

    Norton, Maureen; Chandra-Mouli, Venkatraman; Lane, Cate

    2017-01-01

    Background: In 2017, of the 22.5 million parenting adolescents (ages 15–19) in 60 countries, approximately 4.1 million gave birth to a second or higher-order child. Adolescent pregnancy in general, and rapid repeat pregnancies specifically, expose young mothers and their children to multiple health and socioeconomic risks. The purpose of this article is to review the impact of interventions designed to prevent unintended, rapid repeat pregnancies among adolescents, including those aimed at changing norms to postpone “intended” closely spaced pregnancies to promote healthy spacing. Methods: We searched PubMed and other databases for evaluations of interventions published in English from 1990 through 2016. We included evaluations that assessed a programmatic intervention specifically designed to prevent rapid repeat pregnancy (occurring less than 24 months after the index birth) or birth (occurring less than 33 months after the index birth), or that reported on contraceptive continuation for at least 2 years. We first assessed the quality of the evaluations, then ranked the interventions based on the quality of the evaluation and the level of impact on repeat pregnancy or birth (statistically significant impact, positive trends but not statistically significant, or no impact) to identify the most effective interventions. Finally, we extracted program design and implementation lessons from the interventions included in the high-quality evaluations. Results: Our search identified 2,187 articles, of which 40 evaluations met the inclusion criteria (24=high quality, 14=moderate quality, 2=less rigorous). We found 14 high-quality evaluations in which the intervention achieved a statistically significant impact on repeat pregnancy or birth. These interventions fell into 5 broad categories: (1) contraceptive services and information, with proactive monitoring of contraceptive use and outreach to families; (2) postpartum contraceptive counseling and services provided soon after delivery; (3) activities that help adolescents improve planning skills, including preparing contraceptive plans; (4) social and behavioral change activities that help adolescents understand the role contraception can play in determining positive life outcomes, and the implications of their reproductive health decisions for their future; and (5) activities that provide mentoring, goal setting, and motivation. Conclusion: Effective interventions that prevent rapid adolescent childbearing link clinical contraceptive services with non-clinical activities that build planning skills, enhance understanding of the role that contraceptives can play in determining positive life outcomes, and provide mentoring and goal setting. Recognizing potentially synergistic effects, we recommend testing various combinations of these interventions, with access to contraception as the foundational activity. PMID:29284694

  3. Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study.

    PubMed

    Yusof, Mohd Yusmiaidil Putera Mohd; Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham

    2017-12-01

    This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.

  4. The Impact of Repeated Freeze-Thaw Cycles on the Quality of Biomolecules in Four Different Tissues.

    PubMed

    Ji, Xiaoli; Wang, Min; Li, Lingling; Chen, Fang; Zhang, Yanyang; Li, Qian; Zhou, Junmei

    2017-10-01

    High-quality biosamples are valuable resources for biomedical research. However, some tissues are stored without being sectioned into small aliquots and have to undergo repeated freeze-thaw cycles throughout prolonged experimentation. Little is known regarding the effects of repeated freeze-thaw cycles on the quality of biomolecules in tissues. The aim of this study was to evaluate the impact of repeated freeze-thaw (at room temperature or on ice) cycles on biomolecules and gene expression in four different types of tissues. Each fresh tissue was sectioned into seven aliquots and snap-frozen before undergoing repeated freeze-thaw cycles at room temperature or on ice. Biomolecules were extracted and analyzed. Both relative and absolute quantification were used to detect the changes in gene expression. The results indicated that the impact of repeated freeze-thaw cycles on RNA integrity varied by tissue type. Gene expression, including the housekeeping gene, was affected in RNA-degraded samples according to absolute quantification rather than relative quantification. Furthermore, our results suggest that thawing on ice could protect RNA integrity compared with thawing at room temperature. No obvious degradation of protein or DNA was observed with repeated freeze-thaw cycles either at room temperature or on ice. This research provides ample evidence for the necessity of sectioning fresh tissues into small aliquots before snap-freezing, thus avoiding degradation of RNA and alteration of gene expression resulting from repeated freeze-thaw cycles. For frozen tissue samples that were already in storage and had to be used repeatedly during their lifecycle, thawing on ice or sectioned at ultralow temperature is recommended.

  5. Does Poor Spelling Equate to Slow Reading? The Relationship between Reading, Spelling, and Orthographic Quality

    ERIC Educational Resources Information Center

    Martin-Chang, Sandra; Ouellette, Gene; Madden, Melanie

    2014-01-01

    High quality lexical representations in memory, characterized by accuracy and stability, are said to underpin fluent reading. Here, the relationship between orthographic quality and reading speed was examined by asking undergraduates (N = 74) to repeatedly read and spell words. Spelling performance over five trials indicated orthographic quality.…

  6. Repeated growth and bubbling transfer of graphene with millimetre-size single-crystal grains using platinum.

    PubMed

    Gao, Libo; Ren, Wencai; Xu, Huilong; Jin, Li; Wang, Zhenxing; Ma, Teng; Ma, Lai-Peng; Zhang, Zhiyong; Fu, Qiang; Peng, Lian-Mao; Bao, Xinhe; Cheng, Hui-Ming

    2012-02-28

    Large single-crystal graphene is highly desired and important for the applications of graphene in electronics, as grain boundaries between graphene grains markedly degrade its quality and properties. Here we report the growth of millimetre-sized hexagonal single-crystal graphene and graphene films joined from such grains on Pt by ambient-pressure chemical vapour deposition. We report a bubbling method to transfer these single graphene grains and graphene films to arbitrary substrate, which is nondestructive not only to graphene, but also to the Pt substrates. The Pt substrates can be repeatedly used for graphene growth. The graphene shows high crystal quality with the reported lowest wrinkle height of 0.8 nm and a carrier mobility of greater than 7,100 cm(2) V(-1) s(-1) under ambient conditions. The repeatable growth of graphene with large single-crystal grains on Pt and its nondestructive transfer may enable various applications.

  7. Repeated growth and bubbling transfer of graphene with millimetre-size single-crystal grains using platinum

    PubMed Central

    Gao, Libo; Ren, Wencai; Xu, Huilong; Jin, Li; Wang, Zhenxing; Ma, Teng; Ma, Lai-Peng; Zhang, Zhiyong; Fu, Qiang; Peng, Lian-Mao; Bao, Xinhe; Cheng, Hui-Ming

    2012-01-01

    Large single-crystal graphene is highly desired and important for the applications of graphene in electronics, as grain boundaries between graphene grains markedly degrade its quality and properties. Here we report the growth of millimetre-sized hexagonal single-crystal graphene and graphene films joined from such grains on Pt by ambient-pressure chemical vapour deposition. We report a bubbling method to transfer these single graphene grains and graphene films to arbitrary substrate, which is nondestructive not only to graphene, but also to the Pt substrates. The Pt substrates can be repeatedly used for graphene growth. The graphene shows high crystal quality with the reported lowest wrinkle height of 0.8 nm and a carrier mobility of greater than 7,100 cm2 V−1 s−1 under ambient conditions. The repeatable growth of graphene with large single-crystal grains on Pt and its nondestructive transfer may enable various applications. PMID:22426220

  8. Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

    PubMed Central

    Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham

    2017-01-01

    Purpose This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. Materials and Methods A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. Conclusion The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients. PMID:29279822

  9. Measurement system with high accuracy for laser beam quality.

    PubMed

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  10. Fitness determinants of repeated-sprint ability in highly trained youth football players.

    PubMed

    Spencer, Matt; Pyne, David; Santisteban, Juanma; Mujika, Iñigo

    2011-12-01

    Variations in rates of growth and development in young football players can influence relationships among various fitness qualities. To investigate the relationships between repeated-sprint ability and other fundamental fitness qualities of acceleration, agility, explosive leg power, and aerobic conditioning through the age groups of U11 to U18 in highly trained junior football players. Male players (n = 119) across the age groups completed a fitness assessment battery over two testing sessions. The first session consisted of countermovement jumps without and with arm swing, 15-m sprint run, 15-m agility run, and the 20-m Shuttle Run (U11 to U15) or the Yo-Yo Intermittent Recovery Test, Level 1 (U16 to U18). The players were tested for repeated-sprint ability in the second testing session using a protocol of 6 × 30-m sprints on 30 s with an active recovery. The correlations of repeated-sprint ability with the assorted fitness tests varied considerably between the age groups, especially for agility (r = .02 to .92) and explosive leg power (r = .04 to .84). Correlations of repeated sprint ability with acceleration (r = .48 to .93) and aerobic conditioning (r = .28 to .68) were less variable with age. Repeated-sprint ability associates differently with other fundamental fitness tests throughout the teenage years in highly trained football players, although stabilization of these relationships occurs by the age of 18 y. Coaches in junior football should prescribe physical training accounting for variations in short-term disruptions or impairment of physical performance during this developmental period.

  11. Reducing dislocations in semiconductors utilizing repeated thermal cycling during multistage epitaxial growth

    DOEpatents

    Fan, John C. C.; Tsaur, Bor-Yeu; Gale, Ronald P.; Davis, Frances M.

    1992-02-25

    Dislocation densities are reduced in growing semiconductors from the vapor phase by employing a technique of interrupting growth, cooling the layer so far deposited, and then repeating the process until a high quality active top layer is achieved. The method of interrupted growth, coupled with thermal cycling, permits dislocations to be trapped in the initial stages of epitaxial growth.

  12. Reducing dislocations in semiconductors utilizing repeated thermal cycling during multistage epitaxial growth

    DOEpatents

    Fan, John C. C.; Tsaur, Bor-Yeu; Gale, Ronald P.; Davis, Frances M.

    1986-12-30

    Dislocation densities are reduced in growing semiconductors from the vapor phase by employing a technique of interrupting growth, cooling the layer so far deposited, and then repeating the process until a high quality active top layer is achieved. The method of interrupted growth, coupled with thermal cycling, permits dislocations to be trapped in the initial stages of epitaxial growth.

  13. Effects of Active Sting Damping on Common Research Model Data Quality

    NASA Technical Reports Server (NTRS)

    Acheson, Michael J.; Balakrishna, S.

    2011-01-01

    Recent tests using the Common Research Model (CRM) at the Langley National Transonic Facility (NTF) and the Ames 11-foot Transonic Wind Tunnel (11' TWT) produced large sets of data that have been used to examine the effects of active damping on transonic tunnel aerodynamic data quality. In particular, large statistically significant sets of repeat data demonstrate that the active damping system had no apparent effect on drag, lift and pitching moment repeatability during warm testing conditions, while simultaneously enabling aerodynamic data to be obtained post stall. A small set of cryogenic (high Reynolds number) repeat data was obtained at the NTF and again showed a negligible effect on data repeatability. However, due to a degradation of control power in the active damping system cryogenically, the ability to obtain test data post-stall was not achieved during cryogenic testing. Additionally, comparisons of data repeatability between NTF and 11-ft TWT CRM data led to further (warm) testing at the NTF which demonstrated that for a modest increase in data sampling time, a 2-3 factor improvement in drag, and pitching moment repeatability was readily achieved not related with the active damping system.

  14. The Effect of Image Quality, Repeated Study, and Assessment Method on Anatomy Learning

    ERIC Educational Resources Information Center

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A.; Wainman, Bruce C.

    2017-01-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality…

  15. What can be Learned from Silage Breeding Programs?

    NASA Astrophysics Data System (ADS)

    Lorenz, Aaron J.; Coors, James G.

    Improving the quality of cellulosic ethanol feedstocks through breeding and genetic manipulation could significantly impact the economics of this industry. Attaining this will require comprehensive and rapid characterization of large numbers of samples. There are many similarities between improving corn silage quality for dairy production and improving feedstock quality for cellulosic ethanol. It was our objective to provide insight into what is needed for genetic improvement of cellulosic feedstocks by reviewing the development and operation of a corn silage breeding program. We discuss the evolving definition of silage quality and relate what we have learned about silage quality to what is needed for measuring and improving feedstock quality. In addition, repeatability estimates of corn stover traits are reported for a set of hybrids. Repeatability of theoretical ethanol potential measured by near-infrared spectroscopy is high, suggesting that this trait may be easily improved through breeding. Just as cell wall digestibility has been factored into the latest measurements of silage quality, conversion efficiency should be standardized and included in indices of feedstock quality to maximize overall, economical energy availability.

  16. Image quality characteristics of a novel colour scanning digital ophthalmoscope (SDO) compared with fundus photography.

    PubMed

    Strauss, Rupert W; Krieglstein, Tina R; Priglinger, Siegfried G; Reis, Werner; Ulbig, Michael W; Kampik, Anselm; Neubauer, Aljoscha S

    2007-11-01

    To establish a set of quality parameters for grading image quality and apply those to evaluate the fundus image quality obtained by a new scanning digital ophthalmoscope (SDO) compared with standard slide photography. On visual analogue scales a total of eight image characteristics were defined: overall quality, contrast, colour brilliance, focus (sharpness), resolution and details, noise, artefacts and validity of clinical assessment. Grading was repeated after 4 months to assess repeatability. Fundus images of 23 patients imaged digitally by SDO and by Zeiss 450FF fundus camera using Kodak film were graded side-by-side by three graders. Lens opacity was quantified with the Interzeag Lens Opacity Meter 701. For all of the eight scales of image quality, good repeatability within the graders (mean Kendall's W 0.69) was obtained after 4 months. Inter-grader agreement ranged between 0.31 and 0.66. Despite the SDO's limited nominal image resolution of 720 x 576 pixels, the Zeiss FF 450 camera performed better in only two of the subscales - noise (p = 0.001) and artefacts (p = 0.01). Lens opacities significantly influenced only the two subscales 'resolution' and 'details', which deteriorated with increasing media opacities for both imaging systems. Distinct scales to grade image characteristics of different origin were developed and validated. Overall SDO digital imaging was found to provide fundus pictures of a similarly high level of quality as expert photography on slides.

  17. EPISODIC AIR POLLUTION IS ASSOCIATED WITH INCREASED DNA FRAGMENTATION IN HUMAN SPERM WITHOUT OTHER CHANGES IN SEMEN QUALITY

    EPA Science Inventory

    This study was motivated by a previous report of associations between episodes of high air pollution and alterations in semen quality in young men living in an industrial district of the Czech Republic. Using a repeated measures study design, a cohort of men from this district we...

  18. Mission design for NISAR repeat-pass Interferometric SAR

    NASA Astrophysics Data System (ADS)

    Alvarez-Salazar, Oscar; Hatch, Sara; Rocca, Jennifer; Rosen, Paul; Shaffer, Scott; Shen, Yuhsyen; Sweetser, Theodore; Xaypraseuth, Peter

    2014-10-01

    The proposed spaceborne NASA-ISRO SAR (NISAR) mission would use the repeat-pass interferometric Synthetic Aperture Radar (InSAR) technique to measure the changing shape of Earth's surface at the centimeter scale in support of investigations in solid Earth and cryospheric sciences. Repeat-pass InSAR relies on multiple SAR observations acquired from nearly identical positions of the spacecraft as seen from the ground. Consequently, there are tight constraints on the repeatability of the orbit, and given the narrow field of view of the radar antenna beam, on the repeatability of the beam pointing. The quality and accuracy of the InSAR data depend on highly precise control of both orbital position and observatory pointing throughout the science observation life of the mission. This paper describes preliminary NISAR requirements and rationale for orbit repeatability and attitude control in order to meet science requirements. A preliminary error budget allocation and an implementation approach to meet these allocations are also discussed.

  19. Quality assurance of road roughness measurement.

    DOT National Transportation Integrated Search

    2000-01-01

    This report describes a study designed to establish the accuracy and repeatability of high-speed, road-profiling equipment. This effort focused on a series of roughness validation sites. The study addresses selecting the appropriate sites, determinin...

  20. Miniature inverted-repeat transposable element identification and genetic marker development in Agrostis

    USDA-ARS?s Scientific Manuscript database

    Creeping bentgrass (Agrostis stolonifera L.) is an important species to the turfgrass industry because of its adaptation for use in high quality turf stands such as golf course putting greens, tees, and fairways. A. stolonifera is a highly outcrossing allotetraploid making genetic marker developmen...

  1. Performance characterization of water recovery and water quality from chemical/organic waste products

    NASA Technical Reports Server (NTRS)

    Moses, W. M.; Rogers, T. D.; Chowdhury, H.; Cullingford, H. S.

    1989-01-01

    The water reclamation subsystems currently being evaluated for the Space Shuttle Freedom are briefly reviewed with emphasis on a waste water management system capable of processing wastes containing high concentrations of organic/inorganic materials. The process combines low temperature/pressure to vaporize water with high temperature catalytic oxidation to decompose volatile organics. The reclaimed water is of potable quality and has high potential for maintenance under sterile conditions. Results from preliminary experiments and modifications in process and equipment required to control reliability and repeatability of system operation are presented.

  2. Photomask repeater strategy for high-quality and low-cost reticle fabrication

    NASA Astrophysics Data System (ADS)

    Kyoh, Suigen; Inoue, Soichi; Ikenaga, Osamu; Higaki, Tomotaka; Shigemitsu, Fumiaki; Mori, Ichiro; Kokubo, Haruo; Hayashi, Naoya; Irie, Nobuyuki; Ishii, Yuki; Umatate, Toshikazu

    2003-08-01

    The severe mask specification makes mask cost increase drastically. Especially, the increase in the mask cost deals ASIC businesses a fatal blow due to its small chip volume per product. Pattern writing cost has always occupied the main part of the prime mask cost and the emphasis of this is still increasing. This paper reports on a Photomask Repeater strategy to be a solution for reducing mask cost in pattern writing, comparing with conventional EB system.

  3. Geodynamics branch data base for main magnetic field analysis

    NASA Technical Reports Server (NTRS)

    Langel, Robert A.; Baldwin, R. T.

    1991-01-01

    The data sets used in geomagnetic field modeling at GSFC are described. Data are measured and obtained from a variety of information and sources. For clarity, data sets from different sources are categorized and processed separately. The data base is composed of magnetic observatory data, surface data, high quality aeromagnetic, high quality total intensity marine data, satellite data, and repeat data. These individual data categories are described in detail in a series of notebooks in the Geodynamics Branch, GSFC. This catalog reviews the original data sets, the processing history, and the final data sets available for each individual category of the data base and is to be used as a reference manual for the notebooks. Each data type used in geomagnetic field modeling has varying levels of complexity requiring specialized processing routines for satellite and observatory data and two general routines for processing aeromagnetic, marine, land survey, and repeat data.

  4. Receptionist input to quality and safety in repeat prescribing in UK general practice: ethnographic case study

    PubMed Central

    Greenhalgh, Trisha; Russell, Jill; Myall, Michelle

    2011-01-01

    Objective To describe, explore, and compare organisational routines for repeat prescribing in general practice to identify contributors and barriers to safety and quality. Design Ethnographic case study. Setting Four urban UK general practices with diverse organisational characteristics using electronic patient records that supported semi-automation of repeat prescribing. Participants 395 hours of ethnographic observation of staff (25 doctors, 16 nurses, 4 healthcare assistants, 6 managers, and 56 reception or administrative staff), and 28 documents and other artefacts relating to repeat prescribing locally and nationally. Main outcome measures Potential threats to patient safety and characteristics of good practice. Methods Observation of how doctors, receptionists, and other administrative staff contributed to, and collaborated on, the repeat prescribing routine. Analysis included mapping prescribing routines, building a rich description of organisational practices, and drawing these together through narrative synthesis. This was informed by a sociological model of how organisational routines shape and are shaped by information and communications technologies. Results Repeat prescribing was a complex, technology-supported social practice requiring collaboration between clinical and administrative staff, with important implications for patient safety. More than half of requests for repeat prescriptions were classed as “exceptions” by receptionists (most commonly because the drug, dose, or timing differed from what was on the electronic repeat list). They managed these exceptions by making situated judgments that enabled them (sometimes but not always) to bridge the gap between the idealised assumptions about tasks, roles, and interactions that were built into the electronic patient record and formal protocols, and the actual repeat prescribing routine as it played out in practice. This work was creative and demanded both explicit and tacit knowledge. Clinicians were often unaware of this input and it did not feature in policy documents or previous research. Yet it was sometimes critical to getting the job done and contributed in subtle ways to safeguarding patients. Conclusion Receptionists and administrative staff make important “hidden” contributions to quality and safety in repeat prescribing in general practice, regarding themselves accountable to patients for these contributions. Studying technology-supported work routines that seem mundane, standardised, and automated, but which in reality require a high degree of local tailoring and judgment from frontline staff, opens up a new agenda for the study of patient safety. PMID:22053317

  5. Receptionist input to quality and safety in repeat prescribing in UK general practice: ethnographic case study.

    PubMed

    Swinglehurst, Deborah; Greenhalgh, Trisha; Russell, Jill; Myall, Michelle

    2011-11-03

    To describe, explore, and compare organisational routines for repeat prescribing in general practice to identify contributors and barriers to safety and quality. Ethnographic case study. Four urban UK general practices with diverse organisational characteristics using electronic patient records that supported semi-automation of repeat prescribing. 395 hours of ethnographic observation of staff (25 doctors, 16 nurses, 4 healthcare assistants, 6 managers, and 56 reception or administrative staff), and 28 documents and other artefacts relating to repeat prescribing locally and nationally. Potential threats to patient safety and characteristics of good practice. Observation of how doctors, receptionists, and other administrative staff contributed to, and collaborated on, the repeat prescribing routine. Analysis included mapping prescribing routines, building a rich description of organisational practices, and drawing these together through narrative synthesis. This was informed by a sociological model of how organisational routines shape and are shaped by information and communications technologies. Results Repeat prescribing was a complex, technology-supported social practice requiring collaboration between clinical and administrative staff, with important implications for patient safety. More than half of requests for repeat prescriptions were classed as "exceptions" by receptionists (most commonly because the drug, dose, or timing differed from what was on the electronic repeat list). They managed these exceptions by making situated judgments that enabled them (sometimes but not always) to bridge the gap between the idealised assumptions about tasks, roles, and interactions that were built into the electronic patient record and formal protocols, and the actual repeat prescribing routine as it played out in practice. This work was creative and demanded both explicit and tacit knowledge. Clinicians were often unaware of this input and it did not feature in policy documents or previous research. Yet it was sometimes critical to getting the job done and contributed in subtle ways to safeguarding patients. Conclusion Receptionists and administrative staff make important "hidden" contributions to quality and safety in repeat prescribing in general practice, regarding themselves accountable to patients for these contributions. Studying technology-supported work routines that seem mundane, standardised, and automated, but which in reality require a high degree of local tailoring and judgment from frontline staff, opens up a new agenda for the study of patient safety.

  6. High-quality fiber fabrication in buffered hydrofluoric acid solution with ultrasonic agitation.

    PubMed

    Zhong, Nianbing; Liao, Qiang; Zhu, Xun; Wang, Yongzhong; Chen, Rong

    2013-03-01

    An etching method for preparing high-quality fiber-optic sensors using a buffered etchant with ultrasonic agitation is proposed. The effects of etching conditions on the etch rate and surface morphology of the etched fibers are investigated. The effect of surface roughness is discussed on the fibers' optical properties. Linear etching behavior and a smooth fiber surface can be repeatedly obtained by adjusting the ultrasonic power and etchant pH. The fibers' spectral quality is improved as the ratio of the pit depth to size decreases, and the fibers with smooth surfaces are more sensitive to a bacterial suspension than those with rough surfaces.

  7. Exploring antecedents of consumer satisfaction and repeated search behavior on e-health information.

    PubMed

    Lee, Yun Jung; Park, Jungkun; Widdows, Richard

    2009-03-01

    E-health information has become an important resource for people seeking health information. Even though many studies have been conducted to examine the quality of e-health information, only a few studies have explored the effects of the information seekers' motivations on the perceived quality of e-health information. There is even less information about repeated searches for e-health information after the users' initial experience of e-health information use. Using an online survey of information seekers, 252 e-health information users' responses were collected. The research examines the relationship among motivation, perceived quality, satisfaction, and intention to repeat-search e-health information. The results identify motivations to search e-health information and confirm the relationship among motivation, perceived quality dimensions, and satisfaction and intention to repeat searches for e-health information.

  8. Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self- and parent-administered questionnaires.

    PubMed

    Lampi, Jussi; Ung-Lanki, Sari; Santalahti, Päivi; Pekkanen, Juha

    2018-02-09

    Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self- and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self- and parent administered questionnaires was generally < 0.4 (ICC; k) in reported symptoms and 0.4-0.6 (ICC; k) in perceived indoor air quality. Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.

  9. A systematic review of the quality of statistical methods employed for analysing quality of life data in cancer randomised controlled trials.

    PubMed

    Hamel, Jean-Francois; Saulnier, Patrick; Pe, Madeline; Zikos, Efstathios; Musoro, Jammbe; Coens, Corneel; Bottomley, Andrew

    2017-09-01

    Over the last decades, Health-related Quality of Life (HRQoL) end-points have become an important outcome of the randomised controlled trials (RCTs). HRQoL methodology in RCTs has improved following international consensus recommendations. However, no international recommendations exist concerning the statistical analysis of such data. The aim of our study was to identify and characterise the quality of the statistical methods commonly used for analysing HRQoL data in cancer RCTs. Building on our recently published systematic review, we analysed a total of 33 published RCTs studying the HRQoL methods reported in RCTs since 1991. We focussed on the ability of the methods to deal with the three major problems commonly encountered when analysing HRQoL data: their multidimensional and longitudinal structure and the commonly high rate of missing data. All studies reported HRQoL being assessed repeatedly over time for a period ranging from 2 to 36 months. Missing data were common, with compliance rates ranging from 45% to 90%. From the 33 studies considered, 12 different statistical methods were identified. Twenty-nine studies analysed each of the questionnaire sub-dimensions without type I error adjustment. Thirteen studies repeated the HRQoL analysis at each assessment time again without type I error adjustment. Only 8 studies used methods suitable for repeated measurements. Our findings show a lack of consistency in statistical methods for analysing HRQoL data. Problems related to multiple comparisons were rarely considered leading to a high risk of false positive results. It is therefore critical that international recommendations for improving such statistical practices are developed. Copyright © 2017. Published by Elsevier Ltd.

  10. Investigation of vinegar production using a novel shaken repeated batch culture system.

    PubMed

    Schlepütz, Tino; Büchs, Jochen

    2013-01-01

    Nowadays, bioprocesses are developed or optimized on small scale. Also, vinegar industry is motivated to reinvestigate the established repeated batch fermentation process. As yet, there is no small-scale culture system for optimizing fermentation conditions for repeated batch bioprocesses. Thus, the aim of this study is to propose a new shaken culture system for parallel repeated batch vinegar fermentation. A new operation mode - the flushing repeated batch - was developed. Parallel repeated batch vinegar production could be established in shaken overflow vessels in a completely automated operation with only one pump per vessel. This flushing repeated batch was first theoretically investigated and then empirically tested. The ethanol concentration was online monitored during repeated batch fermentation by semiconductor gas sensors. It was shown that the switch from one ethanol substrate quality to different ethanol substrate qualities resulted in prolonged lag phases and durations of the first batches. In the subsequent batches the length of the fermentations decreased considerably. This decrease in the respective lag phases indicates an adaptation of the acetic acid bacteria mixed culture to the specific ethanol substrate quality. Consequently, flushing repeated batch fermentations on small scale are valuable for screening fermentation conditions and, thereby, improving industrial-scale bioprocesses such as vinegar production in terms of process robustness, stability, and productivity. Copyright © 2013 American Institute of Chemical Engineers.

  11. Implementing Educational Policies in Swaziland. World Bank Discussion Papers No. 88. Africa Technical Department Series.

    ERIC Educational Resources Information Center

    Magalula, Cisco

    At the time of independence in 1968, education in Swaziland was characterized by poor quality, uneven distribution of schools, high dropout and repeater rates, serious shortages of teachers, and inappropriate and highly academic curricula. This paper describes the status of present-day education in Swaziland in terms of the effect of government…

  12. Systematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel disease

    PubMed Central

    Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N

    2017-01-01

    AIM To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. METHODS Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. RESULTS Out of 439 citations, 4 trials fulfilled our inclusion criteria (n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). CONCLUSION In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population. PMID:28932092

  13. Systematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel disease.

    PubMed

    Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N

    2017-08-28

    To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. Out of 439 citations, 4 trials fulfilled our inclusion criteria ( n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population.

  14. Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2016-03-01

    Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model. The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09 mm (translations) and of [Formula: see text] (rotations), maximum observed errors in the order of 0.12 mm (translations) and of [Formula: see text] (rotations), and a reduction repeatability of 0.02 mm and [Formula: see text]. The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality.

  15. Vaginal birth after cesarean: new insights on maternal and neonatal outcomes.

    PubMed

    Guise, Jeanne-Marie; Denman, Mary Anna; Emeis, Cathy; Marshall, Nicole; Walker, Miranda; Fu, Rongwei; Janik, Rosalind; Nygren, Peggy; Eden, Karen B; McDonagh, Marian

    2010-06-01

    To systematically review the evidence about maternal and neonatal outcomes relating to vaginal birth after cesarean (VBAC). Relevant studies were identified from multiple searches of MEDLINE, DARE, and the Cochrane databases (1980 to September 2009) and from recent systematic reviews, reference lists, reviews, editorials, Web sites, and experts. Inclusion criteria limited studies to the English-language and human studies conducted in the United States and developed countries specifically evaluating birth after previous cesarean delivery. Studies focusing on high-risk maternal or neonatal conditions, including breech vaginal delivery, or fewer than 10 patients were excluded. Poor-quality studies were not included in analyses. We identified 3,134 citations and reviewed 963 articles for inclusion; 203 articles met the inclusion criteria and were quality rated. Overall rates of maternal harms were low for both trial of labor and elective repeat cesarean delivery. Although rare in both elective repeat cesarean delivery and trial of labor, maternal mortality was significantly increased for elective repeat cesarean delivery at 0.013% compared with 0.004% for trial of labor. The rates of maternal hysterectomy, hemorrhage, and transfusions did not differ significantly between trial of labor and elective repeat cesarean delivery. The rate of uterine rupture for all women with prior cesarean was 0.30%, and the risk was significantly increased for trial of labor (0.47% compared with 0.03% for elective repeat cesarean delivery). Perinatal mortality was also significantly increased for trial of labor (0.13% compared with 0.05% for elective repeat cesarean delivery). Overall the best evidence suggests that VBAC is a reasonable choice for the majority of women. Adverse outcomes were rare for both elective repeat cesarean delivery and trial of labor. Definitive studies are lacking to identify patients who are at greatest risk for adverse outcomes.

  16. Technologist-Directed Repeat Musculoskeletal and Chest Radiographs: How Often Do They Impact Diagnosis?

    PubMed

    Rosenkrantz, Andrew B; Jacobs, Jill E; Jain, Nidhi; Brusca-Augello, Geraldine; Mechlin, Michael; Parente, Marc; Recht, Michael P

    2017-12-01

    Radiologic technologists may repeat images within a radiographic examination because of perceived suboptimal image quality, excluding these original images from submission to a PACS. This study assesses the appropriateness of technologists' decisions to repeat musculoskeletal and chest radiographs as well as the utility of repeat radiographs in addressing examinations' clinical indication. We included 95 musculoskeletal and 87 chest radiographic examinations in which the technologist repeated one or more images because of perceived image quality issues, rejecting original images from PACS submission. Rejected images were retrieved from the radiograph unit and uploaded for viewing on a dedicated server. Musculoskeletal and chest radiologists reviewed rejected and repeat images in their timed sequence, in addition to the studies' remaining images. Radiologists answered questions regarding the added value of repeat images. The reviewing radiologist agreed with the reason for rejection for 64.2% of musculoskeletal and 60.9% of chest radiographs. For 77.9% and 93.1% of rejected radiographs, the clinical inquiry could have been satisfied without repeating the image. For 75.8% and 64.4%, the repeated images showed improved image quality. Only 28.4% and 3.4% of repeated images were considered to provide additional information that was helpful in addressing the clinical question. Most repeated radiographs (chest more so than musculoskeletal radiographs) did not add significant clinical information or alter diagnosis, although they did increase radiation exposure. The decision to repeat images should be made after viewing the questionable image in context with all images in a study and might best be made by a radiologist rather than the performing technologist.

  17. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    PubMed

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  18. Impact of repeated single-metal and multi-metal pollution events on soil quality.

    PubMed

    Burges, Aritz; Epelde, Lur; Garbisu, Carlos

    2015-02-01

    Most frequently, soil metal pollution results from the occurrence of repeated single-metal and, above all, multi-metal pollution events, with concomitant adverse consequences for soil quality. Therefore, in this study, we evaluated the impact of repeated single-metal and multi-metal (Cd, Pb, Cu, Zn) pollution events on soil quality, as reflected by the values of a variety of soil microbial parameters with potential as bioindicators of soil functioning. Specifically, parameters of microbial activity (potentially mineralizable nitrogen, β-glucosidase and acid phosphatase activity) and biomass (fungal and bacterial gene abundance by RT-qPCR) were determined, in the artificially metal-polluted soil samples, at regular intervals over a period of 26 weeks. Similarly, we studied the evolution over time of CaCl2-extractable metal fractions, in order to estimate metal bioavailability in soil. Different metals showed different values of bioavailability and relative bioavailability ([metal]bio/[metal]tot) in soil throughout the experiment, under both repeated single-metal and multi-metal pollution events. Both repeated Zn-pollution and multi-metal pollution events led to a significant reduction in the values of acid phosphatase activity, and bacterial and fungal gene abundance, reflecting the negative impact of these repeated events on soil microbial activity and biomass, and, hence, soil quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Establishing column batch repeatability according to Quality by Design (QbD) principles using modeling software.

    PubMed

    Rácz, Norbert; Kormány, Róbert; Fekete, Jenő; Molnár, Imre

    2015-04-10

    Column technology needs further improvement even today. To get information of batch-to-batch repeatability, intelligent modeling software was applied. Twelve columns from the same production process, but from different batches were compared in this work. In this paper, the retention parameters of these columns with real life sample solutes were studied. The following parameters were selected for measurements: gradient time, temperature and pH. Based on calculated results, batch-to-batch repeatability of BEH columns was evaluated. Two parallel measurements on two columns from the same batch were performed to obtain information about the quality of packing. Calculating the average of individual working points at the highest critical resolution (R(s,crit)) it was found that the robustness, calculated with a newly released robustness module, had a success rate >98% among the predicted 3(6) = 729 experiments for all 12 columns. With the help of retention modeling all substances could be separated independently from the batch and/or packing, using the same conditions, having high robustness of the experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Few millimeter precision for baselines in the California Permanent GPS Geodetic Array

    NASA Technical Reports Server (NTRS)

    Lindqwister, Ulf J.; Zumberge, James F.; Webb, Frank H.; Blewitt, Geoffrey

    1991-01-01

    Geodetic measurements with Rogue GPS receivers from sites in the California Permanent GPS geodetic Array (PGGA) have been analyzed using the GIPSY orbit-determination and baseline-estimation software. Based on an unbiased selection of 23 daily measurements spanning 8 months, the LF contributions to the long-term repeatabilities of baseline measurements are approximately 5, 3, and 8 mm for the east, north, and vertical components. Short-term contributions to the long-term repeatabilities were evaluated by examining data from the week of October 21, 1990, which showed the lowest short-term scatter. For this week, daily repeatabilities of 2-3 mm in the horizontal and 4 mm in the vertical have been achieved for the 172-km JPL-Pinyon baseline, consistent with carrier phase date noise of about 6 mm. High quality (less than about 5 mm) repeatabilities have been achieved for all components of the other baselines as well.

  1. Repeat Prostate Biopsy Practice Patterns in a Statewide Quality Improvement Collaborative.

    PubMed

    Burks, Frank N; Hu, Jonathan C; Telang, Dinesh; Liu, Alice; Hawken, Scott; Montgomery, Zack; Linsell, Susan; Montie, James E; Miller, David C; Ghani, Khurshid R

    2017-08-01

    We examined rebiopsies in MUSIC (Michigan Urological Surgery Improvement Collaborative) to understand adherence to guidelines recommending repeat prostate biopsy in patients with multifocal high grade prostatic intraepithelial neoplasia or atypical small acinar proliferation. We analyzed data on men undergoing repeat biopsy, practice patterns and cancer detection rates. Multivariate regression modeling was used to calculate the proportion of patients undergoing rebiopsy. We used claims data to validate the treatment classification in MUSIC. To understand reasons for not performing rebiopsy we reviewed records of a sample of patients with atypical small acinar proliferation. We identified 5,375 men with a negative biopsy, of whom 411 (7.6%) underwent repeat biopsy. In 718 men with high grade prostatic intraepithelial neoplasia, 350 with atypical small acinar proliferation and 587 with high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation or atypical small acinar proliferation alone at initial biopsy the rebiopsy rate was 20.7%, 42.5% and 55.6%, respectively. The adjusted proportion of patients with rebiopsy in each practice ranged from 0% to 17.2% (p <0.001). The overall cancer detection rate at rebiopsy was 39.3%. It was highest after atypical small acinar proliferation (adjusted probability 0.39, 95% CI 0.30-0.48), and after high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation (adjusted probability 0.50, 95% CI 0.35-0.65). The greatest Gleason 7 or greatest detection rate of 41.1% was found in patients with high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation. Chart review revealed that 45.5% of patients with atypical small acinar proliferation underwent prostate specific antigen testing instead of rebiopsy while 36% failed to undergo rebiopsy despite a recommendation. Rebiopsy rates vary in Michigan practices with relatively low use in men with high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation or atypical small acinar proliferation alone. Quality improvement strategies should target patients with atypical small acinar proliferation and high grade prostatic intraepithelial neoplasia as they have the highest likelihood of cancer detection. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Effect of Repeated Freeze-Thaw Cycles on Beef Quality and Safety

    PubMed Central

    Rahman, Mohammad Hafizur; Hossain, Mohammad Mujaffar; Rahman, Syed Mohammad Ehsanur; Hashem, Mohammad Abul

    2014-01-01

    The objectives of this study were to know the effect of repeated freeze-thaw cycles of beef on the sensory, physicochemical quality and microbiological assessment. The effects of three successive freeze-thaw cycles on beef forelimb were investigated comparing with unfrozen fresh beef for 75 d by keeping at −20±1℃. The freeze-thaw cycles were subjected to three thawing methods and carried out to know the best one. As the number of freeze-thaw cycles increased color and odor declined significantly before cook within the cycles and tenderness, overall acceptability also declined among the cycles after cook by thawing methods. The thawing loss increased and dripping loss decreased significantly (p<0.05). Water holding capacity (WHC) increased (p<0.05) until two cycles and then decreased. Cooking loss increased in cycle 1 and 3, but decreased in cycle 2. pH decreased significantly (p<0.05) among the cycles. Moreover, drip loss, cooking loss and WHC were affected (p<0.05) by thawing methods within the cycles. 2-Thiobarbituric acid (TBARS) value increased (p<0.05) gradually within the cycles and among the cycles by thawing methods. Total viable bacteria, total coliform and total yeast-mould count decreased significantly (p<0.05) within and among the cycles in comparison to the initial count in repeated freeze-thaw cycles. As a result, repeated freeze-thaw cycles affected the sensory, physicochemical and microbiological qua- lity of beef, causing the deterioration of beef quality, but improved the microbiological quality. Although repeated freeze-thaw cycles did not affect much on beef quality and safety but it may be concluded that repeated freeze and thaw should be minimized in terms of beef color for commercial value and WHC and tenderness/juiciness for eating quality. PMID:26761286

  3. Period 3 gene polymorphism and sleep adaptation to stressful urban environments.

    PubMed

    Anderson, Maxwell R; Akeeb, Ameenat; Lavela, Joseph; Chen, Yuanxiu; Mellman, Thomas A

    2017-02-01

    This study's objective was to investigate the relationship between a variable-number tandem-repeat (VNTR) Period 3 gene (PER3) polymorphism and sleep adaptation to stressful urban environments. Seventy-five (49 female) African American participants (ages 18-35 years) living in neighbourhoods with high rates of violent crime were selected for the study based on converging criteria for good or poor sleep. Categorization of sleep quality was based on the Insomnia Severity Index (ISI), estimates of typical sleep duration and sleep efficiency. Other assessments included the Fear of Sleep Index (FOSI) and City Stress Inventory (CSI). Whole blood DNA was analysed for the 4 and 5 VNTR alleles using polymerase chain reaction (PCR) and restrictive enzyme digestion. Fifty-seven per cent of those who were homo- or heterozygous for the 4-repeat allele were poor sleepers versus 25% of those homozygous for the 5-repeat allele; χ 2  = 4.17, P = 0.041. In a logistic regression model with all the variables with significant bivariate relationships to sleep quality group, FOSI was the only significant predictor (χ 2  = 5.68, P = 0.017). FOSI scores were higher among those with the 4-repeat allele (t = 2.66, P = 0.013). The PER3 4 and 5 VNTR polymorphisms appear to influence sensitivity to the effects of stressful urban environments on sleep. While FOSI was the only variable associated independently with sleep quality category, the candidate vulnerability allele was also associated with greater 'fear of sleep'. © 2016 European Sleep Research Society.

  4. National variety trials identify clones with high potential

    USDA-ARS?s Scientific Manuscript database

    Quality potato varieties are the backbone of a strong potato industry. Variety trials have been used to identify promising new varieties for well over a century. Trials are repeated and information collected over many years in order to confidently identify lines that may be well suited for productio...

  5. Using Chemistry Simulations: Attention Capture, Selective Amnesia and Inattentional Blindness

    ERIC Educational Resources Information Center

    Rodrigues, Susan

    2011-01-01

    Twenty-one convenience sample student volunteers aged between 14-15 years worked in pairs (and one group of three) with two randomly allocated high quality conceptual (molecular level) and operational (mimicking wet labs) simulations. The volunteers were told they had five minutes to play, repeat, review, restart or stop the simulation, which in…

  6. Self-Regulated Mobile Learning and Assessment: An Evaluation of Assessment Interfaces

    ERIC Educational Resources Information Center

    Koorsse, Melisa; Olivier, Werner; Greyling, Jean

    2014-01-01

    Assessment for learning has an important role to play in self-regulated learning but the assessment interface can impact learner motivation and performance. Learners are able to assess their knowledge of learning content and, through repeated assessment and high-quality feedback, close the gap between their current performance and the performance…

  7. The cumulative impacts of repeated heavy rainfall, flooding and altered water quality on the high-latitude coral reefs of Hervey Bay, Queensland, Australia.

    PubMed

    Butler, I R; Sommer, B; Zann, M; Zhao, J-X; Pandolfi, J M

    2015-07-15

    Terrestrial runoff and flooding have resulted in major impacts on coral communities worldwide, but we lack detailed understanding of flood plume conditions and their ecological effects. Over the course of repeated flooding between 2010 and 2013, we measured coral cover and water quality on the high-latitude coral reefs of Hervey Bay, Queensland, Australia. In 2013, salinity, total suspended solids, total nitrogen and total phosphorus were altered for up to six months post-flooding. Submarine groundwater caused hypo-saline conditions for a further four months. Despite the greater magnitude of flooding in 2013, declines in coral abundance (∼28%) from these floods were lower than the 2011 flood (∼40%), which occurred immediately after a decade of severe drought. There was an overall cumulative decrease of coral by ∼56% from 2010 to 2013. Our study highlights the need for local scale monitoring and research to facilitate informed management and conservation of catchments and marine environments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Cost-effectiveness analysis of repeat fine-needle aspiration for thyroid biopsies read as atypia of undetermined significance.

    PubMed

    Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord

    2012-09-01

    The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.

  9. The effect of image quality, repeated study, and assessment method on anatomy learning.

    PubMed

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A; Wainman, Bruce C

    2017-06-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality images of the human hand and human eye. On day 0, participants learned about each anatomical specimen from paper booklets using either low-quality or high-quality images, and then completed a comprehension test using either 2D images or three-dimensional (3D) cadaveric specimens. On day 1, participants relearned each booklet, and on day 2 participants completed a final comprehension test using either 2D images or 3D cadaveric specimens. The effect of image quality on learning varied according to anatomical content, with high-quality images having a greater effect on improving learning of hand anatomy than eye anatomy (high-quality vs. low-quality for hand anatomy P = 0.018; high-quality vs. low-quality for eye anatomy P = 0.247). Also, the benefit of high-quality images on hand anatomy learning was restricted to performance on short-answer (SA) questions immediately after learning (high-quality vs. low-quality on SA questions P = 0.018), but did not apply to performance on multiple-choice (MC) questions (high-quality vs. low-quality on MC questions P = 0.109) or after participants had an additional learning opportunity (24 hours later) with anatomy content (high vs. low on SA questions P = 0.643). This study underscores the limited impact of image quality on anatomy learning, and questions whether investment in enhancing image quality of learning aids significantly promotes knowledge development. Anat Sci Educ 10: 249-261. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  10. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    PubMed

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  11. De novo identification of highly diverged protein repeats by probabilistic consistency.

    PubMed

    Biegert, A; Söding, J

    2008-03-15

    An estimated 25% of all eukaryotic proteins contain repeats, which underlines the importance of duplication for evolving new protein functions. Internal repeats often correspond to structural or functional units in proteins. Methods capable of identifying diverged repeated segments or domains at the sequence level can therefore assist in predicting domain structures, inferring hypotheses about function and mechanism, and investigating the evolution of proteins from smaller fragments. We present HHrepID, a method for the de novo identification of repeats in protein sequences. It is able to detect the sequence signature of structural repeats in many proteins that have not yet been known to possess internal sequence symmetry, such as outer membrane beta-barrels. HHrepID uses HMM-HMM comparison to exploit evolutionary information in the form of multiple sequence alignments of homologs. In contrast to a previous method, the new method (1) generates a multiple alignment of repeats; (2) utilizes the transitive nature of homology through a novel merging procedure with fully probabilistic treatment of alignments; (3) improves alignment quality through an algorithm that maximizes the expected accuracy; (4) is able to identify different kinds of repeats within complex architectures by a probabilistic domain boundary detection method and (5) improves sensitivity through a new approach to assess statistical significance. Server: http://toolkit.tuebingen.mpg.de/hhrepid; Executables: ftp://ftp.tuebingen.mpg.de/pub/protevo/HHrepID

  12. High-resolution audiometry: an automated method for hearing threshold acquisition with quality control.

    PubMed

    Bian, Lin

    2012-01-01

    In clinical practice, hearing thresholds are measured at only five to six frequencies at octave intervals. Thus, the audiometric configuration cannot closely reflect the actual status of the auditory structures. In addition, differential diagnosis requires quantitative comparison of behavioral thresholds with physiological measures, such as otoacoustic emissions (OAEs) that are usually measured in higher resolution. The purpose of this research was to develop a method to improve the frequency resolution of the audiogram. A repeated-measure design was used in the study to evaluate the reliability of the threshold measurements. A total of 16 participants with clinically normal hearing and mild hearing loss were recruited from a population of university students. No intervention was involved in the study. Custom developed system and software were used for threshold acquisition with quality control (QC). With real-ear calibration and monitoring of test signals, the system provided accurate and individualized measure of hearing thresholds that were determined by an analysis based on signal detection theory (SDT). The reliability of the threshold measure was assessed by correlation and differences between the repeated measures. The audiometric configurations were diverse and unique to each individual ear. The accuracy, within-subject reliability, and between-test repeatability are relatively high. With QC, the high-resolution audiograms can be reliably and accurately measured. Hearing thresholds measured as ear canal sound pressures with higher frequency resolution can provide more customized hearing-aid fitting. The test system may be integrated with other physiological measures, such as OAEs, into a comprehensive evaluative tool. American Academy of Audiology.

  13. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    NASA Astrophysics Data System (ADS)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  14. Reputation and Competition in a Hidden Action Model

    PubMed Central

    Fedele, Alessandro; Tedeschi, Piero

    2014-01-01

    The economics models of reputation and quality in markets can be classified in three categories. (i) Pure hidden action, where only one type of seller is present who can provide goods of different quality. (ii) Pure hidden information, where sellers of different types have no control over product quality. (iii) Mixed frameworks, which include both hidden action and hidden information. In this paper we develop a pure hidden action model of reputation and Bertrand competition, where consumers and firms interact repeatedly in a market with free entry. The price of the good produced by the firms is contractible, whilst the quality is noncontractible, hence it is promised by the firms when a contract is signed. Consumers infer future quality from all available information, i.e., both from what they know about past quality and from current prices. According to early contributions, competition should make reputation unable to induce the production of high-quality goods. We provide a simple solution to this problem by showing that high quality levels are sustained as an outcome of a stationary symmetric equilibrium. PMID:25329387

  15. Reputation and competition in a hidden action model.

    PubMed

    Fedele, Alessandro; Tedeschi, Piero

    2014-01-01

    The economics models of reputation and quality in markets can be classified in three categories. (i) Pure hidden action, where only one type of seller is present who can provide goods of different quality. (ii) Pure hidden information, where sellers of different types have no control over product quality. (iii) Mixed frameworks, which include both hidden action and hidden information. In this paper we develop a pure hidden action model of reputation and Bertrand competition, where consumers and firms interact repeatedly in a market with free entry. The price of the good produced by the firms is contractible, whilst the quality is noncontractible, hence it is promised by the firms when a contract is signed. Consumers infer future quality from all available information, i.e., both from what they know about past quality and from current prices. According to early contributions, competition should make reputation unable to induce the production of high-quality goods. We provide a simple solution to this problem by showing that high quality levels are sustained as an outcome of a stationary symmetric equilibrium.

  16. Assessment of Image Quality of Repeated Limited Transthoracic Echocardiography After Cardiac Surgery.

    PubMed

    Canty, David J; Heiberg, Johan; Tan, Jen A; Yang, Yang; Royse, Alistair G; Royse, Colin F; Mobeirek, Abdulelah; Shaer, Fayez El; Albacker, Turki; Nazer, Rakan I; Fouda, Muhammed; Bakir, Bakir M; Alsaddique, Ahmed A

    2017-06-01

    The use of limited transthoracic echocardiography (TTE) has been restricted in patients after cardiac surgery due to reported poor image quality. The authors hypothesized that the hemodynamic state could be evaluated in a high proportion of patients at repeated intervals after cardiac surgery. Prospective observational study. Tertiary university hospital. The study comprised 51 patients aged 18 years or older presenting for cardiac surgery. Patients underwent TTE before surgery and at 3 time points after cardiac surgery. Images were assessed offline using an image quality scoring system by 2 expert observers. Hemodynamic state was assessed using the iHeartScan protocol, and the primary endpoint was the proportion of limited TTE studies in which the hemodynamic state was interpretable at each of the 3 postoperative time points. Hemodynamic state interpretability varied over time and was highest before surgery (90%) and lowest on the first postoperative day (49%) (p<0.01). This variation in interpretability over time was reflected in all 3 transthoracic windows, ranging from 43% to 80% before surgery and from 2% to 35% on the first postoperative day (p<0.01). Image quality scores were highest with the apical window, ranging from 53% to 77% across time points, and lowest with the subcostal window, ranging from 4% to 70% across time points (p< 0.01). Hemodynamic state can be determined with TTE in a high proportion of cardiac surgery patients after extubation and removal of surgical drains. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Evaluating Quality and Adequacy of Gastrointestinal Samples Collected using Reusable or Disposable Forceps.

    PubMed

    Cartwright, J A; Hill, T L; Smith, S; Shaw, D

    2016-07-01

    Sample quality of gastrointestinal endoscopic biopsies is of paramount importance for accurate histological diagnosis. Many veterinary practices use reusable forceps as a result of perceived decreased cost. With reusable forceps, it remains unknown whether sample quality declines with repeated use and becomes inferior to single-use forceps and is therefore more or less cost effective than single-use forceps. The study hypothesis was that reusable forceps sample quality would deteriorate after repeated use as compared to single-use forceps. Sixty-five dogs undergoing gastrointestinal endoscopy for diagnostic investigations at the Hospital for Small Animals, Edinburgh University. A prospective, pathologist-blinded study comparing single-use and reusable alligator standard cup biopsy forceps (Olympus 2.0 mm 1550 mm) with 5 randomized reusable forceps. Sample quality (stomach, duodenum, ileum, and colon) was assessed by a single pathologist using the WSAVA guidelines. There was no difference in the adequacy, depth, villi number, or crush artifact in the 4 intestinal areas between forceps type with at least 10, and up to 15, repeated uses of the reusable forceps. This study demonstrates that reusable cup biopsy forceps provide equivalent biopsy quality after repeated uses to single-use forceps and are cost effective at 10-case use. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  18. Methods for making deposited films with improved microstructures

    DOEpatents

    Patten, James W.; Moss, Ronald W.; McClanahan, Edwin D.

    1982-01-01

    Methods for improving microstructures of line-of-sight deposited films are described. Columnar growth defects ordinarily produced by geometrical shadowing during deposition of such films are eliminated without resorting to post-deposition thermal or mechanical treatments. The native, as-deposited coating qualities, including homogeneity, fine grain size, and high coating-to-substrate adherence, can thus be retained. The preferred method includes the steps of emitting material from a source toward a substrate to deposit a coating non-uniformly on the substrate surface, removing a portion of the coating uniformly over the surface, again depositing material onto the surface, but from a different direction, and repeating the foregoing steps. The quality of line-of-sight deposited films such as those produced by sputtering, progressively deteriorates as the angle of incidence between the flux and the surface becomes increasingly acute. Depositing non-uniformly, so that the coating becomes progressively thinner as quality deteriorates, followed by uniformly removing some of the coating, such as by resputtering, eliminates the poor quality portions, leaving only high quality portions of the coating. Subsequently sputtering from a different direction applies a high quality coating to other regions of the surface. Such steps can be performed either simultaneously or sequentially to apply coatings of a uniformly high quality, closed microstructure to three-dimensional or larger planar surfaces.

  19. Deposited films with improved microstructures

    DOEpatents

    Patten, James W.; Moss, Ronald W.; McClanahan, Edwin D.

    1984-01-01

    Methods for improving microstructures of line-of-sight deposited films are described. Columnar growth defects ordinarily produced by geometrical shadowing during deposition of such films are eliminated without resorting to post-deposition thermal or mechanical treatments. The native, as-deposited coating qualities, including homogeneity, fine grain size, and high coating-to-substrate adherence, can thus be retained. The preferred method includes the steps of emitting material from a source toward a substrate to deposit a coating non-uniformly on the substrate surface, removing a portion of the coating uniformly over the surface, again depositing material onto the surface, but from a different direction, and repeating the foregoing steps. The quality of line-of-sight deposited films such as those produced by sputtering, progressively deteriorates as the angle of incidence between the flux and the surface becomes increasingly acute. Depositing non-uniformly, so that the coating becomes progressively thinner as quality deteriorates, followed by uniformly removing some of the coating, such as by resputtering, eliminates the poor quality portions, leaving only high quality portions of the coating. Subsequently sputtering from a different direction applies a high quality coating to other regions of the surface. Such steps can be performed either simultaneously or sequentially to apply coatings of a uniformly high quality, closed microstructure to three-dimensional or large planar surfaces.

  20. Wellbeing Understanding in High Quality Healthcare Informatics and Telepractice.

    PubMed

    Fiorini, Rodolfo A; De Giacomo, Piero; L'Abate, Luciano

    2016-01-01

    The proper use of healthcare informatics technology and multidimensional conceptual clarity are fundamental to create and boost outstanding clinical and telepractice results. Avoiding even terminology ambiguities is mandatory for high quality of care service. For instance, well-being or wellbeing is a different way to write the same concept only, or there is a good deal of ambiguity around the meanings of these terms the way they are written. In personal health, healthcare and healthcare informatics, this kind of ambiguity and lack of conceptual clarity has been called out repeatedly over the past 50 years. It is time to get the right, terse scenario. We present a brief review to develop and achieve ultimate wellbeing understanding for practical high quality healthcare informatics and telepractice application. This article presents an innovative point of view on deeper wellbeing understanding towards its increased clinical effective application.

  1. Pre-Service Education for Primary School English Teachers in Indonesia: Policy Implications

    ERIC Educational Resources Information Center

    Zein, Subhan

    2016-01-01

    Although English is only an extra-curricular subject at primary level in Indonesia, expectations over the improved quality of the teachers are exceptionally high. This is the case in the past few years in which the low proficiency of primary English teachers and their lack of teaching competencies have repeatedly been pointed out as major…

  2. Formal education of patients about to undergo laparoscopic cholecystectomy.

    PubMed

    Gurusamy, Kurinchi Selvan; Vaughan, Jessica; Davidson, Brian R

    2014-02-28

    Generally, before being operated on, patients will be given informal information by the healthcare providers involved in the care of the patients (doctors, nurses, ward clerks, or healthcare assistants). This information can also be provided formally in different formats including written information, formal lectures, or audio-visual recorded information. To compare the benefits and harms of formal preoperative patient education for patients undergoing laparoscopic cholecystectomy. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (Issue 2, 2013), MEDLINE, EMBASE, and Science Citation Index Expanded to March 2013. We included only randomised clinical trials irrespective of language and publication status. Two review authors independently extracted the data. We planned to calculate the risk ratio with 95% confidence intervals (CI) for dichotomous outcomes, and mean difference (MD) or standardised mean difference (SMD) with 95% CI for continuous outcomes based on intention-to-treat analyses when data were available. A total of 431 participants undergoing elective laparoscopic cholecystectomy were randomised to formal patient education (215 participants) versus standard care (216 participants) in four trials. The patient education included verbal education, multimedia DVD programme, computer-based multimedia programme, and Power Point presentation in the four trials. All the trials were of high risk of bias. One trial including 212 patients reported mortality. There was no mortality in either group in this trial. None of the trials reported surgery-related morbidity, quality of life, proportion of patients discharged as day-procedure laparoscopic cholecystectomy, the length of hospital stay, return to work, or the number of unplanned visits to the doctor. There were insufficient details to calculate the mean difference and 95% CI for the difference in pain scores at 9 to 24 hours (1 trial; 93 patients); and we did not identify clear evidence of an effect on patient knowledge (3 trials; 338 participants; SMD 0.19; 95% CI -0.02 to 0.41; very low quality evidence), patient satisfaction (2 trials; 305 patients; SMD 0.48; 95% CI -0.42 to 1.37; very low quality evidence), or patient anxiety (1 trial; 76 participants; SMD -0.37; 95% CI -0.82 to 0.09; very low quality evidence) between the two groups.A total of 173 participants undergoing elective laparoscopic cholecystectomy were randomised to electronic consent with repeat-back (patients repeating back the information provided) (92 participants) versus electronic consent without repeat-back (81 participants) in one trial of high risk of bias. The only outcome reported in this trial was patient knowledge. The effect on patient knowledge between the patient education with repeat-back versus patient education without repeat-back groups was imprecise and based on 1 trial of 173 participants; SMD 0.07; 95% CI -0.22 to 0.37; very low quality evidence). Due to the very low quality of the current evidence, the effects of formal patient education provided in addition to the standard information provided by doctors to patients compared with standard care remain uncertain. Further well-designed randomised clinical trials of low risk of bias are necessary.

  3. Differences between physician social networks for cardiac surgery serving communities with high versus low proportions of black residents.

    PubMed

    Hollingsworth, John M; Funk, Russell J; Garrison, Spencer A; Owen-Smith, Jason; Kaufman, Samuel R; Landon, Bruce E; Birkmeyer, John D

    2015-02-01

    Compared with white patients, black patients are more likely to undergo cardiac surgery at low-quality hospitals, even when they live closer to high-quality ones. Opportunities for organizational interventions to alleviate this problem remain elusive. To explore physician isolation in communities with high proportions of black residents as a factor contributing to racial disparities in access to high-quality hospitals for cardiac surgery. Using national Medicare data (2008-2011), we mapped physician social networks at hospitals where coronary artery bypass grafting procedures were performed, measuring their degree of connectedness. We then fitted a series of multivariate regression models to examine for associations between physician connectedness and the proportion of black residents in the hospital service area (HSA) served by each network. Measures of physician connectedness (ie, repeat-tie fraction, clustering, and number of external ties). After accounting for regional differences in healthcare capacity, the social networks of physicians practicing in areas with more black residents varied in many important respects from those of HSAs with fewer black residents. Physicians serving HSAs with many black residents had a smaller number of repeated interactions with each other than those in other HSAs (P<0.001). When these physicians did interact, they tended to assemble in smaller groups of highly interconnected colleagues (P<0.001). They also had fewer interactions with physicians outside their immediate geographic area (P=0.048). Physicians in HSAs with many black residents are more isolated than those in HSAs with fewer black residents. This isolation may negatively impact on care coordination and information sharing. As such, planned delivery system reforms that encourage minorities to seek care within their established local networks may further exacerbate existing surgical disparities.

  4. Potential of dynamically harmonized Fourier transform ion cyclotron resonance cell for high-throughput metabolomics fingerprinting: control of data quality.

    PubMed

    Habchi, Baninia; Alves, Sandra; Jouan-Rimbaud Bouveresse, Delphine; Appenzeller, Brice; Paris, Alain; Rutledge, Douglas N; Rathahao-Paris, Estelle

    2018-01-01

    Due to the presence of pollutants in the environment and food, the assessment of human exposure is required. This necessitates high-throughput approaches enabling large-scale analysis and, as a consequence, the use of high-performance analytical instruments to obtain highly informative metabolomic profiles. In this study, direct introduction mass spectrometry (DIMS) was performed using a Fourier transform ion cyclotron resonance (FT-ICR) instrument equipped with a dynamically harmonized cell. Data quality was evaluated based on mass resolving power (RP), mass measurement accuracy, and ion intensity drifts from the repeated injections of quality control sample (QC) along the analytical process. The large DIMS data size entails the use of bioinformatic tools for the automatic selection of common ions found in all QC injections and for robustness assessment and correction of eventual technical drifts. RP values greater than 10 6 and mass measurement accuracy of lower than 1 ppm were obtained using broadband mode resulting in the detection of isotopic fine structure. Hence, a very accurate relative isotopic mass defect (RΔm) value was calculated. This reduces significantly the number of elemental composition (EC) candidates and greatly improves compound annotation. A very satisfactory estimate of repeatability of both peak intensity and mass measurement was demonstrated. Although, a non negligible ion intensity drift was observed for negative ion mode data, a normalization procedure was easily applied to correct this phenomenon. This study illustrates the performance and robustness of the dynamically harmonized FT-ICR cell to perform large-scale high-throughput metabolomic analyses in routine conditions. Graphical abstract Analytical performance of FT-ICR instrument equipped with a dynamically harmonized cell.

  5. Recommendations of the DNA Commission of the International Society for Forensic Genetics (ISFG) on quality control of autosomal Short Tandem Repeat allele frequency databasing (STRidER).

    PubMed

    Bodner, Martin; Bastisch, Ingo; Butler, John M; Fimmers, Rolf; Gill, Peter; Gusmão, Leonor; Morling, Niels; Phillips, Christopher; Prinz, Mechthild; Schneider, Peter M; Parson, Walther

    2016-09-01

    The statistical evaluation of autosomal Short Tandem Repeat (STR) genotypes is based on allele frequencies. These are empirically determined from sets of randomly selected human samples, compiled into STR databases that have been established in the course of population genetic studies. There is currently no agreed procedure of performing quality control of STR allele frequency databases, and the reliability and accuracy of the data are largely based on the responsibility of the individual contributing research groups. It has been demonstrated with databases of haploid markers (EMPOP for mitochondrial mtDNA, and YHRD for Y-chromosomal loci) that centralized quality control and data curation is essential to minimize error. The concepts employed for quality control involve software-aided likelihood-of-genotype, phylogenetic, and population genetic checks that allow the researchers to compare novel data to established datasets and, thus, maintain the high quality required in forensic genetics. Here, we present STRidER (http://strider.online), a publicly available, centrally curated online allele frequency database and quality control platform for autosomal STRs. STRidER expands on the previously established ENFSI DNA WG STRbASE and applies standard concepts established for haploid and autosomal markers as well as novel tools to reduce error and increase the quality of autosomal STR data. The platform constitutes a significant improvement and innovation for the scientific community, offering autosomal STR data quality control and reliable STR genotype estimates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Improving the Quality of Radiographs in Neonatal Intensive Care Unit Utilizing Educational Interventions.

    PubMed

    Gupta, Ashish O; Rorke, Jeanne; Abubakar, Kabir

    2015-08-01

    We aimed to develop an educational tool to improve the radiograph quality, sustain this improvement overtime, and reduce the number of repeat radiographs. A three phase quality control study was conducted at a tertiary care NICU. A retrospective data collection (phase1) revealed suboptimal radiograph quality and led to an educational intervention and development of X-ray preparation checklist (primary intervention), followed by a prospective data collection for 4 months (phase 2). At the end of phase 2, interim analysis revealed a gradual decline in radiograph quality, which prompted a more comprehensive educational session with constructive feedback to the NICU staff (secondary intervention), followed by another data collection for 6 months (phase 3). There was a significant improvement in the quality of radiographs obtained after primary educational intervention (phase 2) compared with phase 1 (p < 0.001). During interim analysis after phase 2, radiograph quality declined but still remained significantly better than phase 1. Secondary intervention resulted in significant improvement in radiograph quality to > 95% in all domains of image quality. No radiographs were repeated in phase 3, compared with 5.8% (16/277) in phase 1. A structured, collaborated educational intervention successfully improves the radiograph quality and decreases the need for repeat radiographs and radiation exposure in the neonates. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. The case for restraint in spinal surgery: does quality management have a role to play?

    PubMed Central

    Mirza, Sohail K.

    2009-01-01

    Most quality improvement efforts in surgery have focused on the technical quality of care provided, rather than whether the care was indicated, or could have been provided with a safer procedure. Because risk is inherent in any procedure, reducing the number of unnecessary operations is an important issue in patient safety. In the case of lumbar spine surgery, several lines of evidence suggest that, in at least some locations, there may be excessively high surgery rates. This evidence comes from international comparisons of surgical rates; study of small area variations within countries; increasing surgical rates in the absence of new indications; comparisons of surgical outcomes between geographic areas with high or low surgical rates; expert opinion; the preferences of well-informed patients; and increasing rates of repeat surgery. From a population perspective, reducing unnecessary surgery may have a greater impact on complication rates than improving the technical quality of surgery that is performed. Evidence suggests this may be true for coronary bypass surgery in the US and hysterectomy rates in Canada. Though similar studies have not been done for spine surgery, wide geographic variations in surgical rates suggest that this could be the case for spine surgery as well. We suggest that monitoring geographic variations in surgery rates may become an important aspect of quality improvement, and that rates of repeat surgery may bear special attention. Patient registries can help in this regard, if they are very complete and rigorously maintained. They can provide data on surgical rates; offer post-marketing surveillance for new surgical devices and techniques; and help to identify patient subgroups that may benefit most from certain procedures. PMID:19266220

  8. The case for restraint in spinal surgery: does quality management have a role to play?

    PubMed

    Deyo, Richard A; Mirza, Sohail K

    2009-08-01

    Most quality improvement efforts in surgery have focused on the technical quality of care provided, rather than whether the care was indicated, or could have been provided with a safer procedure. Because risk is inherent in any procedure, reducing the number of unnecessary operations is an important issue in patient safety. In the case of lumbar spine surgery, several lines of evidence suggest that, in at least some locations, there may be excessively high surgery rates. This evidence comes from international comparisons of surgical rates; study of small area variations within countries; increasing surgical rates in the absence of new indications; comparisons of surgical outcomes between geographic areas with high or low surgical rates; expert opinion; the preferences of well-informed patients; and increasing rates of repeat surgery. From a population perspective, reducing unnecessary surgery may have a greater impact on complication rates than improving the technical quality of surgery that is performed. Evidence suggests this may be true for coronary bypass surgery in the US and hysterectomy rates in Canada. Though similar studies have not been done for spine surgery, wide geographic variations in surgical rates suggest that this could be the case for spine surgery as well. We suggest that monitoring geographic variations in surgery rates may become an important aspect of quality improvement, and that rates of repeat surgery may bear special attention. Patient registries can help in this regard, if they are very complete and rigorously maintained. They can provide data on surgical rates; offer post-marketing surveillance for new surgical devices and techniques; and help to identify patient subgroups that may benefit most from certain procedures.

  9. Application of FTA sample collection and DNA purification system on the determination of CTG trinucleotide repeat size by PCR-based Southern blotting.

    PubMed

    Hsiao, K M; Lin, H M; Pan, H; Li, T C; Chen, S S; Jou, S B; Chiu, Y L; Wu, M F; Lin, C C; Li, S Y

    1999-01-01

    Myotonic dystrophy (DM) is caused by a CTG trinucleotide expansion mutation at exon 15 of the myotonic dystrophy protein kinase gene. The clinical severity of this disease correlates with the length of the CTG trinucleotide repeats. Determination of the CTG repeat length has been primarily relied on by Southern blot analysis of restriction enzyme-digested genomic DNA. The development of PCR-based Southern blotting methodology provides a much more sensitive and simpler protocol for DM diagnosis. However, the quality of the template and the high (G+C) ratio of the amplified region hamper the use of PCR on the diagnosis of DM. A modified PCR protocol to amplify different lengths of CTG repeat region using various concentrations of 7deaza-dGTP has been reported (1). Here we describe a procedure including sample collection, DNA purification, and PCR analysis of CTG repeat length without using 7-deaza-dGTP. This protocol is very sensitive and convenient because only a small number of nucleate cells are needed for detection of CTG expansion. Therefore, it could be very useful in clinical and prenatal diagnosis as well as in prevalence study of DM.

  10. The genomic basis of adaptive evolution in threespine sticklebacks

    PubMed Central

    Jones, Felicity C; Grabherr, Manfred G; Chan, Yingguang Frank; Russell, Pamela; Mauceli, Evan; Johnson, Jeremy; Swofford, Ross; Pirun, Mono; Zody, Michael C; White, Simon; Birney, Ewan; Searle, Stephen; Schmutz, Jeremy; Grimwood, Jane; Dickson, Mark C; Myers, Richard M; Miller, Craig T; Summers, Brian R; Knecht, Anne K; Brady, Shannon D; Zhang, Haili; Pollen, Alex A; Howes, Timothy; Amemiya, Chris; Lander, Eric S; Di Palma, Federica

    2012-01-01

    Summary Marine stickleback fish have colonized and adapted to innumerable streams and lakes formed since the last ice age, providing an exceptional opportunity to characterize genomic mechanisms underlying repeated ecological adaptation in nature. Here we develop a high quality reference genome assembly for threespine sticklebacks. By sequencing the genomes of 20 additional individuals from a global set of marine and freshwater populations, we identify a genome-wide set of loci that are consistently associated with marine-freshwater divergence. Our results suggest that reuse of globally-shared standing genetic variation, including chromosomal inversions, plays an important role in repeated evolution of distinct marine and freshwater sticklebacks, and in the maintenance of divergent ecotypes during early stages of reproductive isolation. Both coding and regulatory changes occur in the set of loci underlying marine-freshwater evolution, with regulatory changes likely predominating in this classic example of repeated adaptive evolution in nature. PMID:22481358

  11. Digital elevation model generation from satellite interferometric synthetic aperture radar: Chapter 5

    USGS Publications Warehouse

    Lu, Zhong; Dzurisin, Daniel; Jung, Hyung-Sup; Zhang, Lei; Lee, Wonjin; Lee, Chang-Wook

    2012-01-01

    An accurate digital elevation model (DEM) is a critical data set for characterizing the natural landscape, monitoring natural hazards, and georeferencing satellite imagery. The ideal interferometric synthetic aperture radar (InSAR) configuration for DEM production is a single-pass two-antenna system. Repeat-pass single-antenna satellite InSAR imagery, however, also can be used to produce useful DEMs. DEM generation from InSAR is advantageous in remote areas where the photogrammetric approach to DEM generation is hindered by inclement weather conditions. There are many sources of errors in DEM generation from repeat-pass InSAR imagery, for example, inaccurate determination of the InSAR baseline, atmospheric delay anomalies, and possible surface deformation because of tectonic, volcanic, or other sources during the time interval spanned by the images. This chapter presents practical solutions to identify and remove various artifacts in repeat-pass satellite InSAR images to generate a high-quality DEM.

  12. The genomic basis of adaptive evolution in threespine sticklebacks.

    PubMed

    Jones, Felicity C; Grabherr, Manfred G; Chan, Yingguang Frank; Russell, Pamela; Mauceli, Evan; Johnson, Jeremy; Swofford, Ross; Pirun, Mono; Zody, Michael C; White, Simon; Birney, Ewan; Searle, Stephen; Schmutz, Jeremy; Grimwood, Jane; Dickson, Mark C; Myers, Richard M; Miller, Craig T; Summers, Brian R; Knecht, Anne K; Brady, Shannon D; Zhang, Haili; Pollen, Alex A; Howes, Timothy; Amemiya, Chris; Baldwin, Jen; Bloom, Toby; Jaffe, David B; Nicol, Robert; Wilkinson, Jane; Lander, Eric S; Di Palma, Federica; Lindblad-Toh, Kerstin; Kingsley, David M

    2012-04-04

    Marine stickleback fish have colonized and adapted to thousands of streams and lakes formed since the last ice age, providing an exceptional opportunity to characterize genomic mechanisms underlying repeated ecological adaptation in nature. Here we develop a high-quality reference genome assembly for threespine sticklebacks. By sequencing the genomes of twenty additional individuals from a global set of marine and freshwater populations, we identify a genome-wide set of loci that are consistently associated with marine-freshwater divergence. Our results indicate that reuse of globally shared standing genetic variation, including chromosomal inversions, has an important role in repeated evolution of distinct marine and freshwater sticklebacks, and in the maintenance of divergent ecotypes during early stages of reproductive isolation. Both coding and regulatory changes occur in the set of loci underlying marine-freshwater evolution, but regulatory changes appear to predominate in this well known example of repeated adaptive evolution in nature.

  13. High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: impact of butylscopolamine on image quality.

    PubMed

    Wagner, M; Klessen, C; Rief, M; Elgeti, T; Taupitz, M; Hamm, B; Asbach, P

    2008-05-01

    Respiratory triggering allows the acquisition of high-resolution magnetic resonance (MR) images of the upper abdomen. However, the depiction of organs close to the gastrointestinal tract can be considerably impaired by ghosting artifacts and blurring caused by bowel peristalsis. To evaluate the effect of gastrointestinal motion suppression by intramuscular butylscopolamine administration on the image quality of a respiratory-triggered T2-weighted turbo spin-echo (T2w TSE) sequence of the upper abdomen. Images of 46 patients were retrospectively analyzed. Twenty-four patients had received intramuscular injection of 40 mg butylscopolamine immediately before MR imaging. Fourteen of the 24 patients in the butylscopolamine group underwent repeat imaging after a mean of 29 min. Quantitative analysis of the ghosting artifacts was done by measuring signal intensities in regions of interest placed in air anterior to the patient. In addition, image quality was assessed qualitatively by two radiologists by consensus. Spasmolytic medication with butylscopolamine reduced ghosting artifacts and significantly improved image quality of the respiratory-triggered T2w TSE sequence. The most pronounced effect of butylscopolamine administration on image quality was found for the pancreas and the left hepatic lobe. The rate of examinations with excellent or good depiction of the pancreas and the left hepatic lobe in the group without premedication and in the butylscopolamine group was 55% vs. 96% (pancreatic head), 35% vs. 88% (pancreatic body), 43% vs. 96% (pancreatic tail), and 45% vs. 83% (left hepatic lobe), respectively. Regarding the duration of the effect of intramuscular butylscopolamine, repeat imaging after a mean of 29 min did not result in a significant deterioration of image quality. Intramuscular butylscopolamine administration significantly improves image quality of respiratory-triggered T2-weighted abdominal MR imaging by persistent reduction of peristaltic artifacts. MR imaging of the liver and pancreas in particular benefits from the suppression of gastrointestinal peristalsis by butylscopolamine.

  14. Dedicated education unit: student perspectives.

    PubMed

    Nishioka, Vicki M; Coe, Michael T; Hanita, Makoto; Moscato, Susan R

    2014-01-01

    The study compared students' perceptions of their clinical learning experiences in a dedicated education unit (DEU) with their experiences in traditional clinical education. Unlike traditional academic-instructor models, expert nurses in the DEU provide clinical education to students with faculty support. This repeated measures design used student surveys, supplemented by focus group data. Students were more likely to agree that their clinical learning experience was high quality and they had a consistent mentoring relationship during DEU rotations. Students also reported the quality of the unit's learning environment, the leadership style of the nurse manager, and the nursing care on the unit was more favorable in DEUs than traditional units. Consistent with their changed role in DEUs, faculty members were less active in helping students integrate theory and practice. These findings provide additional evidence of the value that the DEU model contributes to high-quality clinical education.

  15. Q-switched all-solid-state lasers and application in processing of thin-film solar cell

    NASA Astrophysics Data System (ADS)

    Liu, Liangqing; Wang, Feng

    2009-08-01

    Societal pressure to renewable clean energy is increasing which is expected to be used as part of an overall strategy to address global warming and oil crisis. Photovoltaic energy conversion devices are on a rapidly accelerating growth path driven by government, of which the costs and prices lower continuously. The next generation thin-film devices are considered to be more efficiency and greatly reduced silicon consumption, resulting in dramatically lower per unit fabrication costs. A key aspect of these devices is patterning large panels to create a monolithic array of series-interconnected cells to form a low current, high voltage module. This patterning is accomplished in three critical scribing processes called P1, P2, and P3. All-solid-state Q-switched lasers are the technology of choice for these processes, due to their advantages of compact configuration, high peak-value power, high repeat rate, excellent beam quality and stability, delivering the desired combination of high throughput and narrow, clean scribes. The end pumped all-solid-state lasers could achieve 1064nm IR resources with pulse width of nanoseconds adopting acoustic-optics Q-switch, shorter than 20ns. The repeat rate is up to 100kHz and the beam quality is close to diffraction limit. Based on this, 532nm green lasers, 355nm UV lasers and 266nm DUV lasers could be carried out through nonlinear frequency conversion. Different wave length lasers are chose to process selective materials. For example, 8-15 W IR lasers are used to scribe the TCO film (P1); 1-5 W green lasers are suitable for scribing the active semiconductor layers (P2) and the back contact layers (P3). Our company, Wuhan Lingyun Photo-electronic System Co. Ltd, has developed 20W IR and 5W green end-pumped Q-switched all-solid-state lasers for thin-film solar industry. Operating in high repeat rates, the speed of processing is up to 2.0 m/s.

  16. Repeatability and Reproducibility of Decisions by Latent Fingerprint Examiners

    PubMed Central

    Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia

    2012-01-01

    The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner) results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive) was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as “difficult” than for “easy” or “moderate” comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4); 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization). Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases. PMID:22427888

  17. Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality.

    PubMed

    Nauer, Claude Bertrand; Zubler, Christoph; Weisstanner, Christian; Stieger, Christof; Senn, Pascal; Arnold, Andreas

    2012-03-01

    The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80 kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3 mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = -0.94/-0.88) and was highest at 80 kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80 kV. However, image quality improvement was most relevant for low-dose scans. Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80 kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocols.

  18. Natural Language Processing: A Tutorial. Revision

    DTIC Science & Technology

    1990-01-01

    English in word-for-word language translations. An oft-repeated (although fictional) anecdote illustrates the ... English by a language translation program, became: " The vodka is strong but 3 the steak is rotten." The point made is that vast amounts of knowledge...are required for effective language translations. The initial goal for Language Translation was "fully-automatic high-quality translation" (FAHOT).

  19. Purification of HgI.sub.2 for nuclear detector fabrication

    DOEpatents

    Schieber, Michael M.

    1978-01-01

    A process for purification of mercuric iodide (HgI.sub.2) to be used as a source material for the growth of detector quality crystals. The high purity HgI.sub.2 raw material is produced by a combination of three stages: synthesis of HgI.sub.2 from Hg and I.sub.2, repeated sublimation, and zone refining.

  20. Children's Performance on Pseudoword Repetition Depends on Auditory Trace Quality: Evidence from Event-Related Potentials.

    ERIC Educational Resources Information Center

    Ceponiene, Rita; Service, Elisabet; Kurjenluoma, Sanna; Cheour, Marie; Naatanen, Risto

    1999-01-01

    Compared the mismatch-negativity (MMN) component of auditory event-related brain potentials to explore the relationship between phonological short-term memory and auditory-sensory processing in 7- to 9-year olds scoring the highest and lowest on a pseudoword repetition test. Found that high and low repeaters differed in MMN amplitude to speech…

  1. A novel approach to TEM preparation with a (7-axis stage) triple-beam FIB-SEM system

    NASA Astrophysics Data System (ADS)

    Clarke, Jamil J.

    2015-10-01

    Preparation of lamellae from bulk to grid for Cs-corrected Transmission Electron Microscope (TEM) observation has mostly become routine work on the latest FIB-SEM systems, with standardized techniques that often are left to automation for the initial steps. The finalization of lamellae however, has mostly become, non-routine, non-repeatable and often driven by user experience level in most cases to produce high quality damage-less cross section. Materials processing of the latest technologies, with ever-shrinking Nano-sized structures pose challenges to modern FIB-SEM systems. This can often lead to specialized techniques and hyper-specific functions for producing ultra-thin high quality lamellae that often are lab specific, preventing practical use of such techniques across multiple materials and applications. Several factors that should be incorporated in processing fine structured materials successfully include how the use of electron and ion scan conditions can affect a thin section during ion milling, the type of ion species applied for material processing during the finalization of lamellae with gallium ions or of a smaller ion species type such as Ar/Xe, sample orientation of the lamella during the thinning process which is linked to ion beam incident angle as a direct relationship in the creation of waterfall effects or curtain effects, and how software can be employed to aid in the reduction of these artifacts with reproducible results regardless of FIB-SEM experience for site-specific lift outs. A traditional TEM preparation was performed of a fine structure specimen in pursuit of a process technique to produce a high quality TEM lamella which would address all of the factors mentioned. These new capabilities have been refined and improved upon during the FIB-SEM design and development stages with an end result of a new approach that yields an improvement in quality by the reduction of common ion milling artifacts such as curtain effects, amorphous material, and better pin pointing of the area of interest while reducing overall processing time for the TEM sample preparation process and enhancing repeatability through ease of use via software controls. The development of these new technologies, incorporating a third Ar/Xe ion beam column in conjunction with the electron and gallium ion beam column, a 7-axis stage for enhanced sample orientation with tilt functions in two axes and automated swing control along with a host of additional functions which address the factors aforementioned such as electron and ion scan techniques and curtain effect removal by the use of hardware and software components that are key to reduce typical FIB related artifacts, all of which are called "ACE [Anti Curtaining Effect] Technologies" are explained. The overall developments of these technologies are to address a significant point that productivity, throughput and repeatability are comprised by synergy between the user, application, software and hardware within a FIB-SEM system. The latest Hitachi FIB-SEM platform offers these innovations for reliability, repeatability and high quality lamella preparation for Cs-corrected (S)TEMs.

  2. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    PubMed

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  3. A new capillary electrophoresis buffer for determining organic and inorganic anions in electroplating bath with surfactant additives.

    PubMed

    Sun, H; Lau, K M; Fung, Y S

    2010-05-07

    Monitoring of trace impurities in electroplating bath is needed to meet EU requirements for WEEE and RoHS and for quality control of electrodeposits. Methods using IC and 100% aqueous CE buffer were found producing non-repeatable results attributed to interference of surfactants and major methanesulphonate anion. A new CE buffer containing 1.5mM tetraethylenepentaamine, 3mM 1,3,5-benzenetricarboxylic acid and 15 mM Tris in 20% (v/v) methanol at pH=8.4 was shown to enhance the separation window, reduce interaction between buffer and bath constituents, and give satisfactory repeatability with baseline separation for 14 organic and inorganic anions within 14 min, good repeatability for migration time (0.32-0.57% RSD), satisfactory peak area and peak height (2.9-4.5 and 3-4.7% respectively), low detection limit (S/N=2, 20-150 ppb), and wide working ranges (0.1-100 ppm). The CE buffer with 20% (v/v) methanol has demonstrated its capability for identifying anion impurities causing problem in aged tin bath and the use of only 10-fold dilution to produce reliable results for quality assessment in plating bath containing high surfactant additives. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. High quality and uniformity GaN grown on 150 mm Si substrate using in-situ NH3 pulse flow cleaning process

    NASA Astrophysics Data System (ADS)

    Ji, Panfeng; Yang, Xuelin; Feng, Yuxia; Cheng, Jianpeng; Zhang, Jie; Hu, Anqi; Song, Chunyan; Wu, Shan; Shen, Jianfei; Tang, Jun; Tao, Chun; Pan, Yaobo; Wang, Xinqiang; Shen, Bo

    2017-04-01

    By using in-situ NH3 pulse flow cleaning method, we have achieved the repeated growth of high quality and uniformity GaN and AlGaN/GaN high electron mobility transistors (HEMTs) on 150 mm Si substrate. The two dimensional electron gas (2DEG) mobility is 2200 cm2/Vs with an electron density of 7.3 × 1012 cm-2. The sheet resistance is 305 ± 4 Ω/□ with ±1.3% variation. The achievement is attributed to the fact that this method can significantly remove the Al, Ga, etc. metal droplets coating on the post growth flow flange and reactor wall which are difficult to clean by normal bake process under H2 ambient.

  5. Validation of a novel computer-assisted sperm analysis (CASA) system using multitarget-tracking algorithms.

    PubMed

    Tomlinson, Mathew James; Pooley, Karen; Simpson, Tracey; Newton, Thomas; Hopkisson, James; Jayaprakasan, Kannamanadias; Jayaprakasan, Rajisha; Naeem, Asad; Pridmore, Tony

    2010-04-01

    To determine the accuracy and precision of a novel computer-assisted sperm analysis (CASA) system by comparison with existing recommended manual methods. Prospective study using comparative measurements of sperm concentration and motility on latex beads and immotile and motile sperm. Tertiary referral fertility center with strong academic links. Sperm donors and male partners of couples attending for fertility investigations. None. Achievement of Accubead target value for high and low concentration suspensions. Repeatability as demonstrated by coefficients of variation and intraclass correlation coefficients. Correlation and limits of agreement between CASA and manual methods. The CASA measurements of latex beads and sperm concentrations demonstrated a high level of accuracy and repeatability. Repeated Accubead measurements attained the required target value (mean difference from target of 2.61% and 3.71% for high- and low-concentration suspensions, respectively) and were highly reproducible. Limits of agreement analysis suggested that manual and CASA counts compared directly could be deemed to be interchangeable. Manual and CASA motility measurements were highly correlated for grades a, b, and d but could not be deemed to be interchangeable, and manual motility estimates were consistently higher for motile sperm. The novel CASA system was able to provide semen quality measurements for sperm concentration and motility measurements which were at least as reliable as current manual methods. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Strategies for high-precision Global Positioning System orbit determination

    NASA Technical Reports Server (NTRS)

    Lichten, Stephen M.; Border, James S.

    1987-01-01

    Various strategies for the high-precision orbit determination of the GPS satellites are explored using data from the 1985 GPS field test. Several refinements to the orbit determination strategies were found to be crucial for achieving high levels of repeatability and accuracy. These include the fine tuning of the GPS solar radiation coefficients and the ground station zenith tropospheric delays. Multiday arcs of 3-6 days provided better orbits and baselines than the 8-hr arcs from single-day passes. Highest-quality orbits and baselines were obtained with combined carrier phase and pseudorange solutions.

  7. A systematic review investigating measurement properties of physiological tests in rugby.

    PubMed

    Chiwaridzo, Matthew; Oorschot, Sander; Dambi, Jermaine M; Ferguson, Gillian D; Bonney, Emmanuel; Mudawarima, Tapfuma; Tadyanemhandu, Cathrine; Smits-Engelsman, Bouwien C M

    2017-01-01

    This systematic review was conducted with the first objective aimed at providing an overview of the physiological characteristics commonly evaluated in rugby and the corresponding tests used to measure each construct. Secondly, the measurement properties of all identified tests per physiological construct were evaluated with the ultimate purpose of identifying tests with strongest level of evidence per construct. The review was conducted in two stages. In all stages, electronic databases of EBSCOhost, Medline and Scopus were searched for full-text articles. Stage 1 included studies examining physiological characteristics in rugby. Stage 2 included studies evaluating measurement properties of all tests identified in Stage 1 either in rugby or related sports such as Australian Rules football and Soccer. Two independent reviewers screened relevant articles from titles and abstracts for both stages. Seventy studies met the inclusion criteria for Stage 1. The studies described 63 tests assessing speed (8), agility/change of direction speed (7), upper-body muscular endurance (8), upper-body muscular power (6), upper-body muscular strength (5), anaerobic endurance (4), maximal aerobic power (4), lower-body muscular power (3), prolonged high-intensity intermittent running ability/endurance (5), lower-body muscular strength (5), repeated high-intensity exercise performance (3), repeated-sprint ability (2), repeated-effort ability (1), maximal aerobic speed (1) and abdominal endurance (1). Stage 2 identified 20 studies describing measurement properties of 21 different tests. Only moderate evidence was found for the reliability of the 30-15 Intermittent Fitness. There was limited evidence found for the reliability and/or validity of 5 m, 10 m, 20 m speed tests, 505 test, modified 505 test, L run test, Sergeant Jump test and bench press repetitions-to-fatigue tests. There was no information from high-quality studies on the measurement properties of all the other tests identified in stage 1. A number of physiological characteristics are evaluated in rugby. Each physiological construct has multiple tests for measurement. However, there is paucity of information on measurement properties from high-quality studies for the tests. This raises questions about the usefulness and applicability of these tests in rugby and creates a need for high-quality future studies evaluating measurement properties of these physiological tests. PROSPERO CRD 42015029747.

  8. Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition.

    PubMed

    Beňovská, Miroslava; Wiewiorka, Ondřej; Pinkavová, Jana

    This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/μl was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/μl (R 2  = 0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.

  9. Sensitivity of immune response quality to influenza helix 190 antigen structure displayed on a modular virus-like particle.

    PubMed

    Anggraeni, Melisa R; Connors, Natalie K; Wu, Yang; Chuan, Yap P; Lua, Linda H L; Middelberg, Anton P J

    2013-09-13

    Biomolecular engineering enables synthesis of improved proteins through synergistic fusion of modules from unrelated biomolecules. Modularization of peptide antigen from an unrelated pathogen for presentation on a modular virus-like particle (VLP) represents a new and promising approach to synthesize safe and efficacious vaccines. Addressing a key knowledge gap in modular VLP engineering, this study investigates the underlying fundamentals affecting the ability of induced antibodies to recognize the native pathogen. Specifically, this quality of immune response is correlated to the peptide antigen module structure. We modularized a helical peptide antigen element, helix 190 (H190) from the influenza hemagglutinin (HA) receptor binding region, for presentation on murine polyomavirus VLP, using two strategies aimed to promote H190 helicity on the VLP. In the first strategy, H190 was flanked by GCN4 structure-promoting elements within the antigen module; in the second, dual H190 copies were arrayed as tandem repeats in the module. Molecular dynamics simulation predicted that tandem repeat arraying would minimize secondary structural deviation of modularized H190 from its native conformation. In vivo testing supported this finding, showing that although both modularization strategies conferred high H190-specific immunogenicity, tandem repeat arraying of H190 led to a strikingly higher immune response quality, as measured by ability to generate antibodies recognizing a recombinant HA domain and split influenza virion. These findings provide new insights into the rational engineering of VLP vaccines, and could ultimately enable safe and efficacious vaccine design as an alternative to conventional approaches necessitating pathogen cultivation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Precision manufacturing for clinical-quality regenerative medicines.

    PubMed

    Williams, David J; Thomas, Robert J; Hourd, Paul C; Chandra, Amit; Ratcliffe, Elizabeth; Liu, Yang; Rayment, Erin A; Archer, J Richard

    2012-08-28

    Innovations in engineering applied to healthcare make a significant difference to people's lives. Market growth is guaranteed by demographics. Regulation and requirements for good manufacturing practice-extreme levels of repeatability and reliability-demand high-precision process and measurement solutions. Emerging technologies using living biological materials add complexity. This paper presents some results of work demonstrating the precision automated manufacture of living materials, particularly the expansion of populations of human stem cells for therapeutic use as regenerative medicines. The paper also describes quality engineering techniques for precision process design and improvement, and identifies the requirements for manufacturing technology and measurement systems evolution for such therapies.

  11. Simultaneous quantification of five major active components in capsules of the traditional Chinese medicine ‘Shu-Jin-Zhi-Tong’ by high performance liquid chromatography

    PubMed Central

    Yang, Xing-Xin; Zhang, Xiao-Xia; Chang, Rui-Miao; Wang, Yan-Wei; Li, Xiao-Ni

    2011-01-01

    A simple and reliable high performance liquid chromatography (HPLC) method has been developed for the simultaneous quantification of five major bioactive components in ‘Shu-Jin-Zhi-Tong’ capsules (SJZTC), for the purposes of quality control of this commonly prescribed traditional Chinese medicine. Under the optimum conditions, excellent separation was achieved, and the assay was fully validated in terms of linearity, precision, repeatability, stability and accuracy. The validated method was applied successfully to the determination of the five compounds in SJZTC samples from different production batches. The HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of SJZTC. PMID:29403711

  12. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Treesearch

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  13. High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence

    PubMed Central

    Podkowa, Anthony S.; Oelze, Michael L.; Ketterling, Jeffrey A.

    2018-01-01

    The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of ±300 mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow. PMID:29910966

  14. Analysis of repeated signals during shell fights in the hermit crab Pagurus bernhardus

    PubMed Central

    Briffa, M.; Elwood, R. W.; Dick, J. T. A.

    1998-01-01

    Shell exchanges between hermit crabs may occur after a period of shell rapping, when the initiating or attacking crab brings its shell rapidly and repeatedly into contact with the shell of the non-initiator or defender, in a series of bouts. There are two opposing models of hermit crab shell exchange and the function of shell rapping. The negotiation model views shell exchange as a mutualistic activity, in which the initiator supplies information about the quality of its shell via the fundamental frequency of the rapping sound. The aggression model views shell rapping as either detrimental to the defending crab, or as providing it with information about the initiator's ability or motivation to continue, or both. The negotiation model makes no predictions about the temporal pattern of rapping, but under the aggression model it would be expected that crabs that rapped more vigorously would be more likely to effect an exchange. Repeating the signal could be expected under either model. Crabs that achieve an exchange rap more vigorously, rapping is more persistent when a clear gain in shell quality may be achieved, and the vigour is greater when the relative resource-holding potential (or 'fighting ability') is high. These findings support the aggression model rather than the negotiation model. Contrary to the predictions of game theory, crabs that do not effect an exchange appear to signal that they are about to give up. The data suggest that rapping is performed repeatedly because the accumulation of all of the performances acts as a signal of stamina.

  15. Comparison of family-planning service quality reported by adolescents and young adult women in Mexico.

    PubMed

    Darney, Blair G; Saavedra-Avendano, Biani; Sosa-Rubi, Sandra G; Lozano, Rafael; Rodriguez, Maria I

    2016-07-01

    Associations between age and patient-reported quality of family planning services were examined among young women in Mexico. A repeated cross-sectional analysis of survey data collected in 2006, 2009, and 2014 was performed. Data from women aged 15-29years who had not undergone sterilization and were currently using a modern contraceptive method were included. The primary outcome was high-quality care, defined as positive responses to all five quality items regarding contraceptive services included in the survey. Multivariable logistic regression and marginal probabilities were used to compare adolescents and women aged 20-29years. The responses of respondents using different contraceptive methods were compared. Data were included from 15 835 individuals. The multivariable analysis demonstrated lower odds of reporting high-quality care among women aged 15-19years (odds ratio 0.73; 95% confidence interval 0.60-0.88) and 20-24years (odds ratio 0.85; 95% confidence interval 0.75-0.96) compared with women aged 25-29years. Adolescents using hormonal and long-acting reversible contraception had significantly lower odds of reporting high-quality care compared with women aged 25-29. Adolescents in Mexico reported a lower quality of family planning services compared with young adult women. Continued research and policies are needed to improve the quality of contraceptive services. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Investigation of electroforming techniques. [fabrication of regeneratively cooled thrust chambers

    NASA Technical Reports Server (NTRS)

    Malone, G. A.

    1975-01-01

    Copper and nickel electroforming was examined for the purpose of establishing the necessary processes and procedures for repeatable, successful fabrication of the outer structures of regeneratively cooled thrust chambers. The selection of electrolytes for copper and nickel deposition is described. The development studies performed to refine and complete the processes necessary for successful chamber shell fabrication and the testing employed to verify the applicability of the processes and procedures to small scale hardware are described. Specifications were developed to afford a guideline for the electroforming of high quality outer shells on regeneratively cooled thrust chamber liners. Test results indicated repeatable mechanical properties could be produced in copper deposits from the copper sulfate electrolyte with periodic current reversal and in nickel deposits from the sulfamate solution. Use of inert, removable channel fillers and the conductivizing of such is described. Techniques (verified by test) which produce high integrity bonds to copper and copper alloy liners are discussed.

  17. Factors influencing repeated teenage pregnancy: a review and meta-analysis.

    PubMed

    Maravilla, Joemer C; Betts, Kim S; Couto E Cruz, Camila; Alati, Rosa

    2017-11-01

    Existing evidence of predictors of repeated teenage pregnancy has not been assessed rigorously. This systematic review provides a comprehensive evaluation of protective and risk factors that are associated with repeated teenage pregnancy through a metaanalytical consensus. We used PubMed, EMBASE, CINAHL, ProQuest, PsychINFO, ScienceDirect, Scopus, and Web of Science databases from 1997-2015 and the reference list of other relevant research papers and related reviews. Eligibility criteria included (1) epidemiologic studies that analyzed factors associated with repeated pregnancy or birth among adolescents <20 years of age who were nulliparous or experienced at least 1 pregnancy, and (2) experimental studies with an observational component that was adjusted for the intervention. We performed narrative synthesis of study characteristics, participant characteristics, study results, and quality assessment. We also conducted random-effects and quality-effects metaanalyses with meta-regression to obtain pooled odds ratios of identified factors and to determine sources of between-study heterogeneity. Twenty-six eligible epidemiologic studies, most from the United States (n=24), showed >47 factors with no evidence of publication bias for each metaanalysis. Use of contraception (pooled odds ratio, 0.60; 95% confidence interval, 0.35-1.02), particularly long-acting reversible contraceptives (pooled odds ratio, 0.19; 95% confidence interval, 0.08-0.45), considerably reduced repeated teenage pregnancy risk. Among studies about contraception, the number of follow-up visits (adjusted coefficient, 0.72; P=.102) and country of study (unadjusted coefficient, 2.57; permuted P=.071) explained between-study heterogeneity. Education-related factors, which included higher level of education (pooled odds ratio, 0.74; 95% confidence interval, 0.60-0.91) and school continuation (pooled odds ratio, 0.53; 95% confidence interval, 0.33-0.84), were found to be protective. Conversely, depression (pooled odds ratio, 1.46; 95% confidence interval, 1.14-1.87), history of abortion (pooled odds ratio, 1.66; 95% confidence interval, 1.08-2.54), and relationship factors, such as partner support, increased the repeated teenage pregnancy risk. Contraceptive use, educational factors, depression, and a history of abortion are the highly influential predictors of repeated teenage pregnancy. However, there is a lack of epidemiologic studies in low- and middle-income countries to measure the extent and characteristics of repeated teenage pregnancy across more varied settings. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Assessment of different methods to estimate bovine colostrum quality on farm.

    PubMed

    Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D

    2016-09-01

    To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.

  19. Development of a Genomic DNA Reference Material Panel for Myotonic Dystrophy Type 1 (DM1) Genetic Testing

    PubMed Central

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine

    2014-01-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132

  20. A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability.

    PubMed

    Wang, Qi; Hou, Yubin; Wang, Junting; Lu, Qingyou

    2013-11-01

    We present a novel homebuilt scanning tunneling microscope (STM) with high quality atomic resolution. It is equipped with a small but powerful GeckoDrive piezoelectric motor which drives a miniature and detachable scanning part to implement coarse approach. The scanning part is a tiny piezoelectric tube scanner (industry type: PZT-8, whose d31 coefficient is one of the lowest) housed in a slightly bigger polished sapphire tube, which is riding on and spring clamped against the knife edges of a tungsten slot. The STM so constructed shows low back-lashing and drifting and high repeatability and immunity to external vibrations. These are confirmed by its low imaging voltages, low distortions in the spiral scanned images, and high atomic resolution quality even when the STM is placed on the ground of the fifth floor without any external or internal vibration isolation devices.

  1. Integrity of high-velocity water slug generated by an impacting technique

    NASA Astrophysics Data System (ADS)

    Dehkhoda, Sevda; Bourne, Neil

    2013-06-01

    A pulsed water jet is a series of discrete water slugs travelling at high velocity. Immediately after striking a target, these slugs apply high-intensity, short-duration transient stress known as the water hammer pressure, followed by low-intensity, long-duration stationary stress at the stagnation pressure. The magnitude and duration of the water hammer and stagnation pressures are controlled by the size and quality of the water slugs. The use of water jets for rock cutting in mining operations is a centuries-old technology; however, practical methods for producing high-energy water slugs repeatedly have proven difficult. This can be partly due to the fact that the geometrical properties of a jet and so its effectiveness in creating damage is controlled and influenced by the method that is employed to generate the water slugs. This paper investigates the integrity of a single water slug produced using an impacting technique where a hammer strikes a piston, resting on top of a water-filled chamber. The coherence of the generated water pulse was of concern in this study. If repeated shock reflections within the chamber were transmitted or were carried into the internal geometry of nozzle, the emerging jet could pulsate. The impact impulse of the formed water jet was measured in a Kel-F target material using an embedded PVDF (Polyvinylidene fluoride) shock gauge. The recorded stress waveform was then used to study the quality and endurance of the water pulse stream as it travelled through air.

  2. Assessment of early radial injury after transradial coronary intervention by high-resolution ultrasound biomicroscopy: innovative technology application.

    PubMed

    Shen, Hua; Zhou, Yu-Jie; Liu, Yu-Yang; DU, Jie; Liu, Xiao-Li; Yan, Zhen-Xian; Wang, Zhi-Jian; Gao, Fei; Yang, Shi-Wei; Jia, De-An; Han, Hong-Ya; Yu, Miao; Ma, Qian; Xu, Xiao-Han

    2012-10-01

    Transradial coronary intervention (TRI) introduces injury to the radial artery (RA) which will affect repeat transradial coronary procedure and the quality as a bypass conduit. We sought to compare the early radial injury after TRI between first-TRI and repeat-TRI by ultrasound biomicroscopy (UBM). A total of 1116 patients who underwent the transradial coronary procedures were enrolled. The patients depending on whether for the first time to accept transradial coronary procedure were divided into first-TRI group and repeat-TRI group. The RA was examined by UBM before and one day after the procedure. Compared with first-TRI group, the mean RA diameter of repeat-TRI one day after the procedure decreased significantly (P < 0.05). In first-TRI group, the mean RA diameter was (2.32 ± 0.53) and (1.93 ± 0.57) mm before procedure and one day after the procedure respectively (P < 0.05). In repeat-TRI group, the mean RA diameter was (2.37 ± 0.51) and (1.79 ± 0.54) mm before procedure and one day after the procedure, respectively (P < 0.01). Compared with first-TRI group, the mean RA diameter was reduced significantly in repeat-TRI group one day after the procedure (P < 0.05). The early radial injuries and intimal thickening were compared between first-TRI and repeat-TRI. The mean intima-media thickness of RA was (0.24 ± 0.13) mm and (0.59 ± 0.28) mm before procedure and one day after the procedure in first-TRI group. The mean intima-media thickness of RA was (0.29 ± 0.16) mm and (0.68 ± 0.32) mm before procedure and one day after the procedure in repeat-TRI group. Compared with first-TRI group, the mean intimal thickening was increased significantly in repeat-TRI group one day after the procedure (P < 0.05). Intimal dissection, stenosis and occlusion were all significantly greater in repeat-TRI RAs (P < 0.05). Linear regression analysis revealed that diameter, repeated TRI procedure and PCI procedure were the independent predictors of intimal thickening. RA early injuries were greater in repeat-TRI patients than in first-TRI patients. We first use high-resolution UBM imaging to demonstrate the rate of radial injury and revealed that diameter, repeated TRI procedure and PCI procedure were the independent predictors of intimal thickening.

  3. Dynamics of Soil Bacterial Communities in Response to Repeated Application of Manure Containing Sulfadiazine

    PubMed Central

    Ding, Guo-Chun; Radl, Viviane; Schloter-Hai, Brigitte; Jechalke, Sven; Heuer, Holger; Smalla, Kornelia; Schloter, Michael

    2014-01-01

    Large amounts of manure have been applied to arable soils as fertilizer worldwide. Manure is often contaminated with veterinary antibiotics which enter the soil together with antibiotic resistant bacteria. However, little information is available regarding the main responders of bacterial communities in soil affected by repeated inputs of antibiotics via manure. In this study, a microcosm experiment was performed with two concentrations of the antibiotic sulfadiazine (SDZ) which were applied together with manure at three different time points over a period of 133 days. Samples were taken 3 and 60 days after each manure application. The effects of SDZ on soil bacterial communities were explored by barcoded pyrosequencing of 16S rRNA gene fragments amplified from total community DNA. Samples with high concentration of SDZ were analyzed on day 193 only. Repeated inputs of SDZ, especially at a high concentration, caused pronounced changes in bacterial community compositions. By comparison with the initial soil, we could observe an increase of the disturbance and a decrease of the stability of soil bacterial communities as a result of SDZ manure application compared to the manure treatment without SDZ. The number of taxa significantly affected by the presence of SDZ increased with the times of manure application and was highest during the treatment with high SDZ-concentration. Numerous taxa, known to harbor also human pathogens, such as Devosia, Shinella, Stenotrophomonas, Clostridium, Peptostreptococcus, Leifsonia, Gemmatimonas, were enriched in the soil when SDZ was present while the abundance of bacteria which typically contribute to high soil quality belonging to the genera Pseudomonas and Lysobacter, Hydrogenophaga, and Adhaeribacter decreased in response to the repeated application of manure and SDZ. PMID:24671113

  4. Dynamics of soil bacterial communities in response to repeated application of manure containing sulfadiazine.

    PubMed

    Ding, Guo-Chun; Radl, Viviane; Schloter-Hai, Brigitte; Jechalke, Sven; Heuer, Holger; Smalla, Kornelia; Schloter, Michael

    2014-01-01

    Large amounts of manure have been applied to arable soils as fertilizer worldwide. Manure is often contaminated with veterinary antibiotics which enter the soil together with antibiotic resistant bacteria. However, little information is available regarding the main responders of bacterial communities in soil affected by repeated inputs of antibiotics via manure. In this study, a microcosm experiment was performed with two concentrations of the antibiotic sulfadiazine (SDZ) which were applied together with manure at three different time points over a period of 133 days. Samples were taken 3 and 60 days after each manure application. The effects of SDZ on soil bacterial communities were explored by barcoded pyrosequencing of 16S rRNA gene fragments amplified from total community DNA. Samples with high concentration of SDZ were analyzed on day 193 only. Repeated inputs of SDZ, especially at a high concentration, caused pronounced changes in bacterial community compositions. By comparison with the initial soil, we could observe an increase of the disturbance and a decrease of the stability of soil bacterial communities as a result of SDZ manure application compared to the manure treatment without SDZ. The number of taxa significantly affected by the presence of SDZ increased with the times of manure application and was highest during the treatment with high SDZ-concentration. Numerous taxa, known to harbor also human pathogens, such as Devosia, Shinella, Stenotrophomonas, Clostridium, Peptostreptococcus, Leifsonia, Gemmatimonas, were enriched in the soil when SDZ was present while the abundance of bacteria which typically contribute to high soil quality belonging to the genera Pseudomonas and Lysobacter, Hydrogenophaga, and Adhaeribacter decreased in response to the repeated application of manure and SDZ.

  5. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    PubMed Central

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  6. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    PubMed

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  7. Translations on Environmental Quality, Number 127

    DTIC Science & Technology

    1976-12-29

    first cleansing is done "by the highly effective method of electrocoagulation . It is "based on the passage of a constant electric flow with a voltage of...chemical rea- gents and becomes suitable for repeated use in industry. With the aid of iod- exchange devices electrocoagulation is supplemented with... electrocoagulation method, it is creating unified devices for the various substances contained in water and is improving plant design. All this will guarantee

  8. Repeatability and Reproducibility of Virtual Subjective Refraction.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-10-01

    To establish the repeatability and reproducibility of a virtual refraction process using simulated retinal images. With simulation software, aberrated images corresponding with each step of the refraction process were calculated following the typical protocol of conventional subjective refraction. Fifty external examiners judged simulated retinal images until the best sphero-cylindrical refraction and the best visual acuity were achieved starting from the aberrometry data of three patients. Data analyses were performed to assess repeatability and reproducibility of the virtual refraction as a function of pupil size and aberrometric profile of different patients. SD values achieved in three components of refraction (M, J0, and J45) are lower than 0.25D in repeatability analysis. Regarding reproducibility, we found SD values lower than 0.25D in the most cases. When the results of virtual refraction with different pupil diameters (4 and 6 mm) were compared, the mean of differences (MoD) obtained were not clinically significant (less than 0.25D). Only one of the aberrometry profiles with high uncorrected astigmatism shows poor results for the M component in reproducibility and pupil size dependence analysis. In all cases, vision achieved was better than 0 logMAR. A comparison between the compensation obtained with virtual and conventional subjective refraction was made as an example of this application, showing good quality retinal images in both processes. The present study shows that virtual refraction has similar levels of precision as conventional subjective refraction. Moreover, virtual refraction has also shown that when high low order astigmatism is present, the refraction result is less precise and highly dependent on pupil size.

  9. Changing personnel behavior to promote quality care practices in an intensive care unit

    PubMed Central

    Cooper, Dominic; Farmery, Keith; Johnson, Martin; Harper, Christine; Clarke, Fiona L; Holton, Phillip; Wilson, Susan; Rayson, Paul; Bence, Hugh

    2005-01-01

    The delivery of safe high quality patient care is a major issue in clinical settings. However, the implementation of evidence-based practice and educational interventions are not always effective at improving performance. A staff-led behavioral management process was implemented in a large single-site acute (secondary and tertiary) hospital in the North of England for 26 weeks. A quasi-experimental, repeated-measures, within-groups design was used. Measurement focused on quality care behaviors (ie, documentation, charting, hand washing). The results demonstrate the efficacy of a staff-led behavioral management approach for improving quality-care practices. Significant behavioral change (F [6, 19] = 5.37, p < 0.01) was observed. Correspondingly, statistically significant (t-test [t] = 3.49, df = 25, p < 0.01) reductions in methicillin-resistant Staphylococcus aureus (MRSA) were obtained. Discussion focuses on implementation issues. PMID:18360574

  10. Force Measurement Improvements to the National Transonic Facility Sidewall Model Support System

    NASA Technical Reports Server (NTRS)

    Goodliff, Scott L.; Balakrishna, Sundareswara; Butler, David; Cagle, C. Mark; Chan, David; Jones, Gregory S.; Milholen, William E., II

    2016-01-01

    The National Transonic Facility is a transonic pressurized cryogenic facility. The development of the high Reynolds number semi-span capability has advanced over the years to include transonic active flow control and powered testing using the sidewall model support system. While this system can be used in total temperatures down to -250Â F for conventional unpowered configurations, it is limited to temperatures above -60Â F when used with powered models that require the use of the high-pressure air delivery system. Thermal instabilities and non-repeatable mechanical arrangements revealed several data quality shortfalls by the force and moment measurement system. Recent modifications to the balance cavity recirculation system have improved the temperature stability of the balance and metric model-to-balance hardware. Changes to the mechanical assembly of the high-pressure air delivery system, particularly hardware that interfaces directly with the model and balance, have improved the repeatability of the force and moment measurement system. Drag comparisons with the high-pressure air system removed will also be presented in this paper.

  11. EMQN/CMGS best practice guidelines for the molecular genetic testing of Huntington disease.

    PubMed

    Losekoot, Monique; van Belzen, Martine J; Seneca, Sara; Bauer, Peter; Stenhouse, Susan A R; Barton, David E

    2013-05-01

    Huntington disease (HD) is caused by the expansion of an unstable polymorphic trinucleotide (CAG)n repeat in exon 1 of the HTT gene, which translates into an extended polyglutamine tract in the protein. Laboratory diagnosis of HD involves estimation of the number of CAG repeats. Molecular genetic testing for HD is offered in a wide range of laboratories both within and outside the European community. In order to measure the quality and raise the standard of molecular genetic testing in these laboratories, the European Molecular Genetics Quality Network has organized a yearly external quality assessment (EQA) scheme for molecular genetic testing of HD for over 10 years. EQA compares a laboratory's output with a fixed standard both for genotyping and reporting of the results to the referring physicians. In general, the standard of genotyping is very high but the clarity of interpretation and reporting of the test result varies more widely. This emphasizes the need for best practice guidelines for this disorder. We have therefore developed these best practice guidelines for genetic testing for HD to assist in testing and reporting of results. The analytical methods and the potential pitfalls of molecular genetic testing are highlighted and the implications of the different test outcomes for the consultand and his or her family members are discussed.

  12. Inadequate pelvic radiographs: implications of not getting it right the first time.

    PubMed

    Parker, S; Nagra, N S; Kulkarni, K; Pegrum, J; Barry, S; Hughes, R; Ghani, Y

    2017-09-01

    Introduction Pelvic radiography is a frequent investigation. European guidelines aim to ensure appropriate use and adequate quality. When initial images are inadequate, repeat radiographs are often required, which may have significant patient safety and economic implications. Objectives The study aimed to assess the adequacy of pelvic imaging across three orthopaedic centres, to identify causes for inadequate imaging and to establish the cost of inadequate imaging from financial and patient safety perspectives. Methods Pelvic radiographs were identified on Picture Archiving and Communication System software at three UK hospitals. Radiographs were assessed against European guidelines and indications for repeat imaging were analysed. Results A total of 1,531 sequential pelvic radiographs were reviewed. The mean age of patients was 60 years (range 5 months to 101 years). Of this total, 51.9% of images were suboptimal, with no significant difference across the three hospitals (P > 0.05). Hospital 3 repeated radiographs in 6.3% of cases, compare with 18.1% and 19.7% at hospitals 1 and 2, respectively (P > 0.05). Hospital 3 identified pathology missed on the initial radiograph in 1% of cases, compared with 5.4% and 5.5% at hospitals 1 and 2, respectively (P > 0.05). Out-of-hours imaging is associated with a higher rate of suboptimal quality (69.1%) compared with normal working hours (51.3%; P = 0.006). Adequacy rates vary with age (χ 2 = 43.62, P < 0.001). Risk of having a suboptimal radiograph increases above the age of 60-years (χ 2 = 4.45, P < 0.05). The annual cost of repeat radiographs was £56,200 per hospital. Discussion and conclusion High rates of pelvic radiograph inadequacy can lead to missed pathology and the requirement for repeat imaging, which has significant patient safety and financial implications. Risk factors for inadequate radiographs include older patients and those having out-of-hours imaging.

  13. Consistency evaluation of values of weight, height, and body mass index in Food Intake and Physical Activity of School Children: the quality control of data entry in the computerized system.

    PubMed

    Jesus, Gilmar Mercês de; Assis, Maria Alice Altenburg de; Kupek, Emil; Dias, Lizziane Andrade

    2017-01-01

    The quality control of data entry in computerized questionnaires is an important step in the validation of new instruments. The study assessed the consistency of recorded weight and height on the Food Intake and Physical Activity of School Children (Web-CAAFE) between repeated measures and against directly measured data. Students from the 2nd to the 5th grade (n = 390) had their weight and height directly measured and then filled out the Web-CAAFE. A subsample (n = 92) filled out the Web-CAAFE twice, three hours apart. The analysis included hierarchical linear regression, mixed linear regression model, to evaluate the bias, and intraclass correlation coefficient (ICC), to assess consistency. Univariate linear regression assessed the effect of gender, reading/writing performance, and computer/internet use and possession on residuals of fixed and random effects. The Web-CAAFE showed high values of ICC between repeated measures (body weight = 0.996, height = 0.937, body mass index - BMI = 0.972), and regarding the checked measures (body weight = 0.962, height = 0.882, BMI = 0.828). The difference between means of body weight, height, and BMI directly measured and recorded was 208 g, -2 mm, and 0.238 kg/m², respectively, indicating slight BMI underestimation due to underestimation of weight and overestimation of height. This trend was related to body weight and age. Height and weight data entered in the Web-CAAFE by children were highly correlated with direct measurements and with the repeated entry. The bias found was similar to validation studies of self-reported weight and height in comparison to direct measurements.

  14. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    PubMed

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  15. Reliability of tonosafe disposable tonometer prisms: clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study.

    PubMed

    Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E

    2011-05-01

    Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test-retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3-34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=-1.05 was significantly different from the hypothesized value. The Tonosafe test-retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.

  16. Reliability of tonosafe disposable tonometer prisms: clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study

    PubMed Central

    Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E

    2011-01-01

    Purpose Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Methods Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test–retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. Results The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3–34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=−1.05 was significantly different from the hypothesized value. The Tonosafe test–retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. Conclusions The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings. PMID:21455241

  17. Quantification of histochemical stains using whole slide imaging: development of a method and demonstration of its usefulness in laboratory quality control.

    PubMed

    Gray, Allan; Wright, Alex; Jackson, Pete; Hale, Mike; Treanor, Darren

    2015-03-01

    Histochemical staining of tissue is a fundamental technique in tissue diagnosis and research, but it suffers from significant variability. Efforts to address this include laboratory quality controls and quality assurance schemes, but these rely on subjective interpretation of stain quality, are laborious and have low reproducibility. We aimed (1) to develop a method for histochemical stain quantification using whole slide imaging and image analysis and (2) to demonstrate its usefulness in measuring staining variation. A method to quantify the individual stain components of histochemical stains on virtual slides was developed. It was evaluated for repeatability and reproducibility, then applied to control sections of an appendix to quantify H&E staining (H/E intensities and H:E ratio) between automated staining machines and to measure differences between six regional diagnostic laboratories. The method was validated with <0.5% variation in H:E ratio measurement when using the same scanner for a batch of slides (ie, it was repeatable) but was not highly reproducible between scanners or over time, where variation of 7% was found. Application of the method showed H:E ratios between three staining machines varied from 0.69 to 0.93, H:E ratio variation over time was observed. Interlaboratory comparison demonstrated differences in H:E ratio between regional laboratories from 0.57 to 0.89. A simple method using whole slide imaging can be used to quantify and compare histochemical staining. This method could be deployed in routine quality assurance and quality control. Work is needed on whole slide imaging devices to improve reproducibility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Nonhybrid, finished microbial genome assemblies from long-read SMRT sequencing data.

    PubMed

    Chin, Chen-Shan; Alexander, David H; Marks, Patrick; Klammer, Aaron A; Drake, James; Heiner, Cheryl; Clum, Alicia; Copeland, Alex; Huddleston, John; Eichler, Evan E; Turner, Stephen W; Korlach, Jonas

    2013-06-01

    We present a hierarchical genome-assembly process (HGAP) for high-quality de novo microbial genome assemblies using only a single, long-insert shotgun DNA library in conjunction with Single Molecule, Real-Time (SMRT) DNA sequencing. Our method uses the longest reads as seeds to recruit all other reads for construction of highly accurate preassembled reads through a directed acyclic graph-based consensus procedure, which we follow with assembly using off-the-shelf long-read assemblers. In contrast to hybrid approaches, HGAP does not require highly accurate raw reads for error correction. We demonstrate efficient genome assembly for several microorganisms using as few as three SMRT Cell zero-mode waveguide arrays of sequencing and for BACs using just one SMRT Cell. Long repeat regions can be successfully resolved with this workflow. We also describe a consensus algorithm that incorporates SMRT sequencing primary quality values to produce de novo genome sequence exceeding 99.999% accuracy.

  19. Improvement of baking quality traits through a diverse soft winter wheat population

    USDA-ARS?s Scientific Manuscript database

    Breeding baking quality improvements into soft winter wheat (SWW) entails crossing lines based on quality traits, assessing new lines, and repeating several times as little is known about the genetics of these traits. Previous research on SWW baking quality focused on quantitative trait locus and ge...

  20. High quality x-ray absorption spectroscopy measurements with long energy range at high pressure using diamond anvil cell.

    PubMed

    Hong, Xinguo; Newville, Matthew; Prakapenka, Vitali B; Rivers, Mark L; Sutton, Stephen R

    2009-07-01

    We describe an approach for acquiring high quality x-ray absorption fine structure (XAFS) spectroscopy spectra with wide energy range at high pressure using diamond anvil cell (DAC). Overcoming the serious interference of diamond Bragg peaks is essential for combining XAFS and DAC techniques in high pressure research, yet an effective method to obtain accurate XAFS spectrum free from DAC induced glitches has been lacking. It was found that these glitches, whose energy positions are very sensitive to the relative orientation between DAC and incident x-ray beam, can be effectively eliminated using an iterative algorithm based on repeated measurements over a small angular range of DAC orientation, e.g., within +/-3 degrees relative to the x-ray beam direction. Demonstration XAFS spectra are reported for rutile-type GeO2 recorded by traditional ambient pressure and high pressure DAC methods, showing similar quality at 440 eV above the absorption edge. Accurate XAFS spectra of GeO2 glass were obtained at high pressure up to 53 GPa, providing important insight into the structural polymorphism of GeO2 glass at high pressure. This method is expected be applicable for in situ XAFS measurements using a diamond anvil cell up to ultrahigh pressures.

  1. High quality x-ray absorption spectroscopy measurements with long energy range at high pressure using diamond anvil cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, X.; Newville, M.; Prakapenka, V.B.

    We describe an approach for acquiring high quality x-ray absorption fine structure (XAFS) spectroscopy spectra with wide energy range at high pressure using diamond anvil cell (DAC). Overcoming the serious interference of diamond Bragg peaks is essential for combining XAFS and DAC techniques in high pressure research, yet an effective method to obtain accurate XAFS spectrum free from DAC induced glitches has been lacking. It was found that these glitches, whose energy positions are very sensitive to the relative orientation between DAC and incident x-ray beam, can be effectively eliminated using an iterative algorithm based on repeated measurements over amore » small angular range of DAC orientation, e.g., within {+-}3{sup o} relative to the x-ray beam direction. Demonstration XAFS spectra are reported for rutile-type GeO{sub 2} recorded by traditional ambient pressure and high pressure DAC methods, showing similar quality at 440 eV above the absorption edge. Accurate XAFS spectra of GeO{sub 2} glass were obtained at high pressure up to 53 GPa, providing important insight into the structural polymorphism of GeO{sub 2} glass at high pressure. This method is expected be applicable for in situ XAFS measurements using a diamond anvil cell up to ultrahigh pressures.« less

  2. Third-party punishment as a costly signal of high continuation probabilities in repeated games.

    PubMed

    Jordan, Jillian J; Rand, David G

    2017-05-21

    Why do individuals pay costs to punish selfish behavior, even as third-party observers? A large body of research suggests that reputation plays an important role in motivating such third-party punishment (TPP). Here we focus on a recently proposed reputation-based account (Jordan et al., 2016) that invokes costly signaling. This account proposed that "trustworthy type" individuals (who are incentivized to cooperate with others) typically experience lower costs of TPP, and thus that TPP can function as a costly signal of trustworthiness. Specifically, it was argued that some but not all individuals face incentives to cooperate, making them high-quality and trustworthy interaction partners; and, because the same mechanisms that incentivize cooperation also create benefits for using TPP to deter selfish behavior, these individuals are likely to experience reduced costs of punishing selfishness. Here, we extend this conceptual framework by providing a concrete, "from-the-ground-up" model demonstrating how this process could work in the context of repeated interactions incentivizing both cooperation and punishment. We show how individual differences in the probability of future interaction can create types that vary in whether they find cooperation payoff-maximizing (and thus make high-quality partners), as well as in their net costs of TPP - because a higher continuation probability increases the likelihood of receiving rewards from the victim of the punished transgression (thus offsetting the cost of punishing). We also provide a simple model of dispersal that demonstrates how types that vary in their continuation probabilities can stably coexist, because the payoff from remaining in one's local environment (i.e. not dispersing) decreases with the number of others who stay. Together, this model demonstrates, from the group up, how TPP can serve as a costly signal of trustworthiness arising from exposure to repeated interactions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Screening injured children for physical abuse or neglect in emergency departments: a systematic review.

    PubMed

    Woodman, J; Lecky, F; Hodes, D; Pitt, M; Taylor, B; Gilbert, Ruth

    2010-03-01

    Screening markers are used in emergency departments (EDs) to identify children who should be assessed for possible physical abuse and neglect. We conducted three systematic reviews evaluating age, repeat attendance and injury type as markers for physical abuse or neglect in injured children attending EDs. We included studies comparing markers in physically abused or neglected children and non-abused injured children attending ED or hospital. We calculated likelihood ratios (LRs) for age group, repeat attendance and injury type (head injury, bruises, fractures, burns or other). Given the low prevalence of abuse or neglect, we considered that an LR of 10 or more would be clinically useful. All studies were poor quality. Infancy increased the risk of physical abuse or neglect in severely injured or admitted children (LRs 7.7-13.0, 2 studies) but was not strongly associated in children attending the ED (LR 1.5, 95% CI: 0.9, 2.8; one study). Repeat attendance did not substantially increase the risk of abuse or neglect and may be confounded by chronic disease and socio-economic status (LRs 0.8-3.9, 3 studies). One study showed no evidence that the type of injury substantially increased the risk of physical abuse or neglect in severely injured children. There was no evidence that any of the markers (infancy, type of injury, repeated attendance) were sufficiently accurate (i.e. LR >or= 10) to screen injured children in the ED to identify those requiring paediatric assessment for possible physical abuse or neglect. Clinicians should be aware that among injured children at ED a high proportion of abused children will present without these characteristics and a high proportion of non-abused children will present with them. Information about age, injury type and repeat attendances should be interpreted in this context.

  4. Satellite sound broadcasting system study: Mobile considerations

    NASA Technical Reports Server (NTRS)

    Golshan, Nasser

    1990-01-01

    Discussed here is the mobile reception part of a study to investigate a satellite sound broadcast system in the UHF or L bands. Existing propagation and reception measurements are used with proper interpretation to evaluate the signaling, coding, and diversity alternatives suitable for the system. Signal attenuation in streets shadowed by buildings appear to be around 29 db, considerably higher than the 10 db adopted by CCIR. With the marriage of proper technologies, an LMSS class satellite can provide substantial direct satellite audio broadcast capability in UHF or L bands for high quality mobile and portable indoor reception by low cost radio receivers. This scheme requires terrestrial repeaters for satisfactory mobile reception in urban areas. A specialized bandwidth efficient spread spectrum signalling technique is particularly suitable for the terrestrial repeaters.

  5. [Customer satisfaction with a quality management system according to DIN EN ISO 9001:2000: Increase in the satisfaction of cooperating clinics].

    PubMed

    Beholz, Sven; Konertz, Wolfgang

    2006-01-01

    The evaluation of customers' satisfaction is elementary for any quality management system. In our university cardiac surgery unit that has been certified according to DIN EN ISO 9001:2000 the influence of repeated evaluation of the referring physicians' satisfaction conducted in the course of three consecutive years on structures and processes in the scope of the quality management system was examined. Customers' satisfaction with the possibility of access to the department could be increased by targeted interventions. Further interventions in the field of documentation led to a measurable increase in satisfaction with postoperative communication. Repeated annual evaluation of the satisfaction of referring physicians has proved to be a valuable tool in the process of continuous quality improvement.

  6. Simultaneous determination of six active components by a single standard to determine multicomponents combined with fingerprint analysis for the quality control of Rhizoma Chuanxiong.

    PubMed

    He, Yufei; Li, Qing; Bi, Kaishun

    2015-04-01

    To control the quality of Rhizoma Chuanxiong, a method based on high-performance liquid chromatography method coupled with diode array detection was developed for the quantitative analysis of six active ingredients using a single standard to determine multi-components and chemical fingerprint analysis for the first time. The separation was performed on an Agilent Zorbax SB-C18 column by gradient elution with methanol and aqueous phase (containing 0.5% glacial acetic acid) at a flow rate of 1.0 mL/min. The UV wavelength was set at 274 nm. This assay was fully validated with respect to precision, repeatability, and accuracy. All calibration curves showed good linearity (R(2) > 0.9994) within test ranges. The limit of detection and limit of quantification were lower than 0.01 and 0.03 μg/mL, respectively. The relative standard deviation for repeatability and the intermediate precision of six analytes were less than 1.6 and 2.5%, respectively, the overall recovery was 96.1-103.1%. In addition, fingerprint chromatography using hierarchical clustering analysis and similarity analysis was performed to differentiate and classify the samples. The method described here could provide a more comprehensive and reasonable scientific assessment of the quality of Rhizoma Chuanxiong. Therefore, the strategy is feasible, credible, and is easily and effectively adapted for evaluating the quality control of Rhizoma Chuanxiong. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Technology to control variation in meat quality

    USDA-ARS?s Scientific Manuscript database

    Consumers have certain expectations regarding the quality of the meat they purchase. Lean color is the primary quality attribute used by consumers to make purchase decisions. Similarly, repeat purchase decisions are generally a result of eating satisfaction, which is determined by the perceived va...

  8. EAPhy: A Flexible Tool for High-throughput Quality Filtering of Exon-alignments and Data Processing for Phylogenetic Methods.

    PubMed

    Blom, Mozes P K

    2015-08-05

    Recently developed molecular methods enable geneticists to target and sequence thousands of orthologous loci and infer evolutionary relationships across the tree of life. Large numbers of genetic markers benefit species tree inference but visual inspection of alignment quality, as traditionally conducted, is challenging with thousands of loci. Furthermore, due to the impracticality of repeated visual inspection with alternative filtering criteria, the potential consequences of using datasets with different degrees of missing data remain nominally explored in most empirical phylogenomic studies. In this short communication, I describe a flexible high-throughput pipeline designed to assess alignment quality and filter exonic sequence data for subsequent inference. The stringency criteria for alignment quality and missing data can be adapted based on the expected level of sequence divergence. Each alignment is automatically evaluated based on the stringency criteria specified, significantly reducing the number of alignments that require visual inspection. By developing a rapid method for alignment filtering and quality assessment, the consistency of phylogenetic estimation based on exonic sequence alignments can be further explored across distinct inference methods, while accounting for different degrees of missing data.

  9. Practical considerations for obtaining high quality quantitative computed tomography data of the skeletal system.

    PubMed

    Troy, Karen L; Edwards, W Brent

    2018-05-01

    Quantitative CT (QCT) analysis involves the calculation of specific parameters such as bone volume and density from CT image data, and can be a powerful tool for understanding bone quality and quantity. However, without careful attention to detail during all steps of the acquisition and analysis process, data can be of poor- to unusable-quality. Good quality QCT for research requires meticulous attention to detail and standardization of all aspects of data collection and analysis to a degree that is uncommon in a clinical setting. Here, we review the literature to summarize practical and technical considerations for obtaining high quality QCT data, and provide examples of how each recommendation affects calculated variables. We also provide an overview of the QCT analysis technique to illustrate additional opportunities to improve data reproducibility and reliability. Key recommendations include: standardizing the scanner and data acquisition settings, minimizing image artifacts, selecting an appropriate reconstruction algorithm, and maximizing repeatability and objectivity during QCT analysis. The goal of the recommendations is to reduce potential sources of error throughout the analysis, from scan acquisition to the interpretation of results. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Method Optimization for Extracting High-Quality RNA From the Human Pancreas Tissue.

    PubMed

    Jun, Eunsung; Oh, Juyun; Lee, Song; Jun, Hye-Ryeong; Seo, Eun Hye; Jang, Jin-Young; Kim, Song Cheol

    2018-06-01

    Nucleic acid sequencing is frequently used to determine the molecular basis of diseases. Therefore, proper storage of biological specimens is essential to inhibit nucleic acid degradation. RNA isolated from the human pancreas is generally of poor quality because of its high concentration of endogenous RNase. In this study, we optimized the method for extracting high quality RNA from paired tumor and normal pancreatic tissues obtained from eight pancreatic cancer patients post-surgery. RNA integrity number (RIN) was checked to evaluate the integrity of RNA, we tried to extract the RNA with an RIN value of 8 or higher that allows for the latest genetic analysis. The effect of several parameters, including the method used for tissue lysis, RNAlater treatment, tissue weight at storage, and the time to storage after surgical resection, on the quantity and quality of RNA extracted was examined. Data showed that the highest quantity of RNA was isolated using a combination of manual and mechanical methods of tissue lysis. Additionally, sectioning the tissues into small pieces (<100 mg) and treating them with RNAlater solution prior to storage increased RNA stability. Following these guidelines, high quality RNA was obtained from 100% (8/8) of tumor tissues and 75% (6/8) of normal tissues. High-quality RNA was still stable under repeated freezing and thawing. The application of these results during sample handling and storage in clinical settings will facilitate the genetic diagnosis of diseases and their subsequent treatment. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Opportunities, challenges and systems requirements for developing post-abortion family planning services: Perceptions of service stakeholders in China

    PubMed Central

    Richards, Esther; Zhang, Weihong; Hu, Lina; Wu, Shangchun; Tolhurst, Rachel

    2017-01-01

    Post-abortion family planning (PAFP) has been proposed as a key strategy to decrease unintended pregnancy and repeat induced abortions. However, the accessibility and quality of PAFP services remain a challenge in many countries including China where more than 10 million unintended pregnancies occur each year. Most of these unwanted pregnancies end in repeated induced abortions. This paper aims to explore service providers’ perceptions of the current situation regarding family planning and abortion service needs, provision, utilization, and the feasibility and acceptability of high quality PAFP in the future. Qualitative methods, including in-depth interviews and focus group discussions, were used with family planning policy makers, health managers, and service providers. Three provinces—Zhejiang, Hubei and Yunnan—were purposively selected, representing high, medium and relatively undeveloped areas of China. A total of fifty-three in-depth interviews and ten focus-group discussions were conducted and analysed thematically. Increased numbers of abortions among young, unmarried women were perceived as a major reason for high numbers of abortions. Participants attributed this to increasing socio-cultural acceptability of premarital sex, and simultaneously, lack of understanding or awareness of contraception among young people. The majority of service stakeholders acknowledged that free family planning services were neither targeted at, nor accessible to unmarried people. The extent of PAFP provision is variable and limited. However, service providers expressed willingness and enthusiasm towards providing PAFP services in the future. Three main considerations were expressed regarding the feasibility of developing and implementing PAFP services: policy support, human resources, and financial resources. The study indicated that key service stakeholders show demand for and perceive considerable opportunities to develop PAFP in China. However, changes are needed to enable the systematic development of high quality PAFP, including actively targeting young and unmarried people in service provision, obtaining policy support and increasing the investment of human and financial resources. PMID:29045434

  12. Opportunities, challenges and systems requirements for developing post-abortion family planning services: Perceptions of service stakeholders in China.

    PubMed

    Jiang, Hong; Xu, Jieshuang; Richards, Esther; Qian, Xu; Zhang, Weihong; Hu, Lina; Wu, Shangchun; Tolhurst, Rachel

    2017-01-01

    Post-abortion family planning (PAFP) has been proposed as a key strategy to decrease unintended pregnancy and repeat induced abortions. However, the accessibility and quality of PAFP services remain a challenge in many countries including China where more than 10 million unintended pregnancies occur each year. Most of these unwanted pregnancies end in repeated induced abortions. This paper aims to explore service providers' perceptions of the current situation regarding family planning and abortion service needs, provision, utilization, and the feasibility and acceptability of high quality PAFP in the future. Qualitative methods, including in-depth interviews and focus group discussions, were used with family planning policy makers, health managers, and service providers. Three provinces-Zhejiang, Hubei and Yunnan-were purposively selected, representing high, medium and relatively undeveloped areas of China. A total of fifty-three in-depth interviews and ten focus-group discussions were conducted and analysed thematically. Increased numbers of abortions among young, unmarried women were perceived as a major reason for high numbers of abortions. Participants attributed this to increasing socio-cultural acceptability of premarital sex, and simultaneously, lack of understanding or awareness of contraception among young people. The majority of service stakeholders acknowledged that free family planning services were neither targeted at, nor accessible to unmarried people. The extent of PAFP provision is variable and limited. However, service providers expressed willingness and enthusiasm towards providing PAFP services in the future. Three main considerations were expressed regarding the feasibility of developing and implementing PAFP services: policy support, human resources, and financial resources. The study indicated that key service stakeholders show demand for and perceive considerable opportunities to develop PAFP in China. However, changes are needed to enable the systematic development of high quality PAFP, including actively targeting young and unmarried people in service provision, obtaining policy support and increasing the investment of human and financial resources.

  13. How Does Premarital Cohabitation Affect Trajectories of Marital Quality?

    ERIC Educational Resources Information Center

    Tach, Laura; Halpern-Meekin, Sarah

    2009-01-01

    We investigate the link between premarital cohabitation and trajectories of subsequent marital quality using random effects growth curve models and repeated measures of marital quality from married women in the NLSY-79 (N = 3,598). We find that premarital cohabitors experience lower quality marital relationships on average, but this is driven by…

  14. Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique.

    PubMed

    Armstrong, Tess; Ly, Karrie V; Murthy, Smruthi; Ghahremani, Shahnaz; Kim, Grace Hyun J; Calkins, Kara L; Wu, Holden H

    2018-05-04

    In adults, noninvasive chemical shift encoded Cartesian magnetic resonance imaging (MRI) and single-voxel magnetic resonance (MR) spectroscopy (SVS) accurately quantify hepatic steatosis but require breath-holding. In children, especially young and sick children, breath-holding is often limited or not feasible. Sedation can facilitate breath-holding but is highly undesirable. For these reasons, there is a need to develop free-breathing MRI technology that accurately quantifies steatosis in all children. This study aimed to compare non-sedated free-breathing multi-echo 3-D stack-of-radial (radial) MRI versus standard breath-holding MRI and SVS techniques in a group of children for fat quantification with respect to image quality, accuracy and repeatability. Healthy children (n=10, median age [±interquartile range]: 10.9 [±3.3] years) and overweight children with nonalcoholic fatty liver disease (NAFLD) (n=9, median age: 15.2 [±3.2] years) were imaged at 3 Tesla using free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS. Acquisitions were performed twice to assess repeatability (within-subject mean difference, MD within ). Images and hepatic proton-density fat fraction (PDFF) maps were scored for image quality. Free-breathing and breath-holding PDFF were compared using linear regression (correlation coefficient, r and concordance correlation coefficient, ρ c ) and Bland-Altman analysis (mean difference). P<0.05 was considered significant. In patients with NAFLD, free-breathing radial MRI demonstrated significantly less motion artifacts compared to breath-holding Cartesian (P<0.05). Free-breathing radial PDFF demonstrated a linear relationship (P<0.001) versus breath-holding SVS PDFF and breath-holding Cartesian PDFF with r=0.996 and ρ c =0.994, and r=0.997 and ρ c =0.995, respectively. The mean difference in PDFF between free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS was <0.7%. Repeated free-breathing radial MRI had MD within =0.25% for PDFF. In this pediatric study, non-sedated free-breathing radial MRI provided accurate and repeatable hepatic PDFF measurements and improved image quality, compared to standard breath-holding MR techniques.

  15. Determination of three steroidal saponins from Ophiopogon japonicus (Liliaceae) via high-performance liquid chromatography with mass spectrometry.

    PubMed

    Wang, Yongyi; Xu, Jinzhong; Qu, Haibin

    2013-01-01

    A simple and accurate analytical method was developed for simultaneous quantification of three steroidal saponins in the roots of Ophiopogon japonicus via high-performance liquid chromatography (HPLC) with mass spectrometry (MS) in this study. Separation was performed on a Tigerkin C(18) column and detection was performed by mass spectrometry. A mobile phase consisted of 0.02% formic acid in water (v/v) and 0.02% formic acid in acetonitrile (v/v) was used with a flow rate of 0.5 mL min(-1). The quantitative HPLC-MS method was validated for linearity, precision, repeatability, stability, recovery, limits of detection and quantification. This developed method provides good linearity (r >0.9993), intra- and inter-day precisions (RSD <4.18%), repeatability (RSD <5.05%), stability (RSD <2.08%) and recovery (93.82-102.84%) for three steroidal saponins. It could be considered as a suitable quality control method for O. japonicus.

  16. A Cesium Rare-Earth Silicate Cs3 RESi6 O15 (RE=Dy-Lu, Y, In): The Parent of an Unusual Structural Class Featuring a Remarkable 57 Å Unit Cell Axis.

    PubMed

    Terry, Rylan; Vinton, Daniel; McMillen, Colin D; Kolis, Joseph W

    2018-02-19

    The structure of Cs 3 RESi 6 O 15 , where RE=Dy-Lu, Y, In, is unusual in that it contains octahedrally coordinated rare-earth ions; their relative orientation dictates the structure, as they rotate about the c-axis supported by the cyclic Si 6 O 15 framework. The repeat unit of the rotation is eight units generating a very long (ca. 57 Å) unit cell axis. This unusual repeat unit is created by the structural flexibility of the hexasilicate ring, which is in turn affected by the size of the rare earth ion as well as the size of alkali ion residing within the silicate layers. Previous work showed for the smaller Sc 3+ ion, the rotation of the octahedra is not sufficient to achieve closure at an integral repeat unit and an incommensurate structure results. The products are prepared as large, high quality single crystals using a high-temperature (650 °C) hydrothermal method with CsOH and F - mineralizers. The presence of fluoride is essential to the formation of the product. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A customized protocol to assess bone quality in the metacarpal head, metacarpal shaft and distal radius: a high resolution peripheral quantitative computed tomography precision study.

    PubMed

    Feehan, Lynne; Buie, Helen; Li, Linda; McKay, Heather

    2013-12-24

    High Resolution-Peripheral Quantitative Computed Tomography (HR-pQCT) is an emerging technology for evaluation of bone quality in Rheumatoid Arthritis (RA). However, there are limitations with standard HR-pQCT imaging protocols for examination of regions of bone commonly affected in RA. We developed a customized protocol for evaluation of volumetric bone mineral density (vBMD) and microstructure at the metacarpal head (MH), metacarpal shaft (MS) and ultra-ultra-distal (UUD) radius; three sites commonly affected in RA. The purpose was to evaluate short-term measurement precision for bone density and microstructure at these sites. 12 non-RA participants, individuals likely to have no pre-existing bone damage, consented to participate [8 females, aged 23 to 71 y [median (IQR): 44 (28) y]. The custom protocol includes more comfortable/stable positioning and adapted cortical segmentation and direct transformation analysis methods. Dominant arm MH, MS and UUD radius scans were completed on day one; repeated twice (with repositioning) three to seven days later. Short-term precision for repeated measures was explored using intraclass correlational coefficient (ICC), mean coefficient of variation (CV%), root mean square coefficient of variation (RMSCV%) and least significant change (LSC%95). Bone density and microstructure precision was excellent: ICCs varied from 0.88 (MH2 trabecular number) to .99 (MS3 polar moment of inertia); CV% varied from < 1 (MS2 vBMD) to 6 (MS3 marrow space diameter); RMSCV% varied from < 1 (MH2 full bone vBMD) to 7 (MS3 marrow space diameter); and LSC%95 varied from 2 (MS2 full bone vBMD to 21 (MS3 marrow space diameter). Cortical porosity measures were the exception; RMSCV% varying from 19 (MS3) to 42 (UUD). No scans were stopped for discomfort. 5% (5/104) were repeated due to motion during imaging. 8% (8/104) of final images had motion artifact graded > 3 on 5 point scale. In our facility, this custom protocol extends the potential for in vivo HR-pQCT imaging to assess, with high precision, regional differences in bone quality at three sites commonly affected in RA. Our methods are easy to adopt and we recommend other users of HR-pQCT consider this protocol for further evaluations of its precision and feasibility in their imaging facilities.

  18. Water Quality-Chapter 5 for National Wetland Condition Assessment technical report

    EPA Science Inventory

    Objectives of the water quality data analyses presented here are to examine the extent to which water quality could be sampled across US wetlands, to evaluate the various measurement endpoints obtained (e.g., variability, repeatability, information content), to present broad patt...

  19. A Protective Eye Shield for Prevention of Media Opacities during Small Animal Ocular Imaging

    PubMed Central

    Bell, Brent A.; Kaul, Charles; Hollyfield, Joe G.

    2014-01-01

    Optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and other non-invasive imaging techniques are increasingly used in eye research to document disease-related changes in rodent eyes. Corneal dehydration is a major contributor to the formation of ocular opacities that can limit the repeated application of these techniques to individual animals. General anesthesia is usually required for imaging, which is accompanied by the loss of the blink reflex. As a consequence, the tear film cannot be maintained, drying occurs and the cornea becomes dehydrated. Without supplemental hydration, structural damage to the cornea quickly follows. Soon thereafter, anterior lens opacities can also develop. Collectively these changes ultimately compromise image quality, especially for studies involving repeated use of the same animal over several weeks or months. To minimize these changes, a protective shield was designed for mice and rats that prevent ocular dehydration during anesthesia. The eye shield, along with a semi-viscous ophthalmic solution, is placed over the corneas as soon as the anesthesia immobilizes the animal. Eye shields are removed for only the brief periods required for imaging and then reapplied before the fellow eye is examined. As a result, the corneal surface of each eye is exposed only for the time required for imaging. The device and detailed methods described here minimize the corneal and lens changes associated with ocular surface desiccation. When these methods are used consistently, high quality images can be obtained repeatedly from individual animals. PMID:25245081

  20. Digital repeat analysis; setup and operation.

    PubMed

    Nol, J; Isouard, G; Mirecki, J

    2006-06-01

    Since the emergence of digital imaging, there have been questions about the necessity of continuing reject analysis programs in imaging departments to evaluate performance and quality. As a marketing strategy, most suppliers of digital technology focus on the supremacy of the technology and its ability to reduce the number of repeats, resulting in less radiation doses given to patients and increased productivity in the department. On the other hand, quality assurance radiographers and radiologists believe that repeats are mainly related to positioning skills, and repeat analysis is the main tool to plan training needs to up-skill radiographers. A comparative study between conventional and digital imaging was undertaken to compare outcomes and evaluate the need for reject analysis. However, digital technology still being at its early development stages, setting a credible reject analysis program became the major task of the study. It took the department, with the help of the suppliers of the computed radiography reader and the picture archiving and communication system, over 2 years of software enhancement to build a reliable digital repeat analysis system. The results were supportive of both philosophies; the number of repeats as a result of exposure factors was reduced dramatically; however, the percentage of repeats as a result of positioning skills was slightly on the increase for the simple reason that some rejects in the conventional system qualifying for both exposure and positioning errors were classified as exposure error. The ability of digitally adjusting dark or light images reclassified some of those images as positioning errors.

  1. Genome Sequencing and Analysis of Yersina pestis KIM D27, an Avirulent Strain Exempt from Select Agent Regulation

    PubMed Central

    Losada, Liliana; Varga, John J.; Hostetler, Jessica; Radune, Diana; Kim, Maria; Durkin, Scott; Schneewind, Olaf; Nierman, William C.

    2011-01-01

    Yersinia pestis is the causative agent of the plague. Y. pestis KIM 10+ strain was passaged and selected for loss of the 102 kb pgm locus, resulting in an attenuated strain, KIM D27. In this study, whole genome sequencing was performed on KIM D27 in order to identify any additional differences. Initial assemblies of 454 data were highly fragmented, and various bioinformatic tools detected between 15 and 465 SNPs and INDELs when comparing both strains, the vast majority associated with A or T homopolymer sequences. Consequently, Illumina sequencing was performed to improve the quality of the assembly. Hybrid sequence assemblies were performed and a total of 56 validated SNP/INDELs and 5 repeat differences were identified in the D27 strain relative to published KIM 10+ sequence. However, further analysis showed that 55 of these SNP/INDELs and 3 repeats were errors in the KIM 10+ reference sequence. We conclude that both 454 and Illumina sequencing were required to obtain the most accurate and rapid sequence results for Y. pestis KIMD27. SNP and INDELS calls were most accurate when both Newbler and CLC Genomics Workbench were employed. For purposes of obtaining high quality genome sequence differences between strains, any identified differences should be verified in both the new and reference genomes. PMID:21559501

  2. Genome sequencing and analysis of Yersina pestis KIM D27, an avirulent strain exempt from select agent regulation.

    PubMed

    Losada, Liliana; Varga, John J; Hostetler, Jessica; Radune, Diana; Kim, Maria; Durkin, Scott; Schneewind, Olaf; Nierman, William C

    2011-04-29

    Yersinia pestis is the causative agent of the plague. Y. pestis KIM 10+ strain was passaged and selected for loss of the 102 kb pgm locus, resulting in an attenuated strain, KIM D27. In this study, whole genome sequencing was performed on KIM D27 in order to identify any additional differences. Initial assemblies of 454 data were highly fragmented, and various bioinformatic tools detected between 15 and 465 SNPs and INDELs when comparing both strains, the vast majority associated with A or T homopolymer sequences. Consequently, Illumina sequencing was performed to improve the quality of the assembly. Hybrid sequence assemblies were performed and a total of 56 validated SNP/INDELs and 5 repeat differences were identified in the D27 strain relative to published KIM 10+ sequence. However, further analysis showed that 55 of these SNP/INDELs and 3 repeats were errors in the KIM 10+ reference sequence. We conclude that both 454 and Illumina sequencing were required to obtain the most accurate and rapid sequence results for Y. pestis KIMD27. SNP and INDELS calls were most accurate when both Newbler and CLC Genomics Workbench were employed. For purposes of obtaining high quality genome sequence differences between strains, any identified differences should be verified in both the new and reference genomes.

  3. [The Quality Analysis of National Supervising Sampling for Rubella Virus IgM Diagnostic Kits in 2014].

    PubMed

    Yu, Tina; Qu, Shoufang; Zhang, Xiaoyan; Sun, Nan; Gao, Shangxian; Li, Haining; Huang, Jie

    2015-07-01

    To evaluate the quality status of rubella virus IgM diagnostic kits by national supervising sampling. Using legal inspection combining with exploratory study, the positive and negative coincidence rate, detection limit and repeatability of kits were verified. The results showed that 15 of 16 batches of kits were qualified using legal inspection, and the passing rate was 93.8%. The unqualified item was negative coincidence rate. In exploratory study, only 11 batches (68.8%) complied with industry standard. The unqualified items were negative coincidence rate, detection limit and repeatability. At present, rubella virus IgM diagnostic Kits have some quality problems in the market. It is recommended that we adopt industry standard and national reference panel in the registration inspection for the future, which will prompt enterprises to improve quality.

  4. High Quality Maize Centromere 10 Sequence Reveals Evidence of Frequent Recombination Events

    PubMed Central

    Wolfgruber, Thomas K.; Nakashima, Megan M.; Schneider, Kevin L.; Sharma, Anupma; Xie, Zidian; Albert, Patrice S.; Xu, Ronghui; Bilinski, Paul; Dawe, R. Kelly; Ross-Ibarra, Jeffrey; Birchler, James A.; Presting, Gernot G.

    2016-01-01

    The ancestral centromeres of maize contain long stretches of the tandemly arranged CentC repeat. The abundance of tandem DNA repeats and centromeric retrotransposons (CR) has presented a significant challenge to completely assembling centromeres using traditional sequencing methods. Here, we report a nearly complete assembly of the 1.85 Mb maize centromere 10 from inbred B73 using PacBio technology and BACs from the reference genome project. The error rates estimated from overlapping BAC sequences are 7 × 10−6 and 5 × 10−5 for mismatches and indels, respectively. The number of gaps in the region covered by the reassembly was reduced from 140 in the reference genome to three. Three expressed genes are located between 92 and 477 kb from the inferred ancestral CentC cluster, which lies within the region of highest centromeric repeat density. The improved assembly increased the count of full-length CR from 5 to 55 and revealed a 22.7 kb segmental duplication that occurred approximately 121,000 years ago. Our analysis provides evidence of frequent recombination events in the form of partial retrotransposons, deletions within retrotransposons, chimeric retrotransposons, segmental duplications including higher order CentC repeats, a deleted CentC monomer, centromere-proximal inversions, and insertion of mitochondrial sequences. Double-strand DNA break (DSB) repair is the most plausible mechanism for these events and may be the major driver of centromere repeat evolution and diversity. In many cases examined here, DSB repair appears to be mediated by microhomology, suggesting that tandem repeats may have evolved to efficiently repair frequent DSBs in centromeres. PMID:27047500

  5. The hazards of bad sleep-Sleep duration and quality as predictors of adolescent alcohol and cannabis use.

    PubMed

    Mike, Thomas B; Shaw, Daniel S; Forbes, Erika E; Sitnick, Stephanie L; Hasler, Brant P

    2016-11-01

    Although an association between adolescent sleep and substance use is supported by the literature, few studies have characterized the longitudinal relationship between early adolescent sleep and subsequent substance use. The current study examined the prospective association between the duration and quality of sleep at age 11 and alcohol and cannabis use throughout adolescence. The present study, drawn from a cohort of 310 boys taking part in a longitudinal study in Western Pennsylvania, includes 186 boys whose mothers completed the Child Sleep Questionnaire; sleep duration and quality at age 11 were calculated based on these reports. At ages 20 and 22, participants were interviewed regarding lifetime alcohol and cannabis use. Cox proportional hazard analysis was used to determine the association between sleep and substance use. After accounting for race, socioeconomic status, neighborhood danger, active distraction, internalizing problems, and externalizing problems, both the duration and quality of sleep at age 11 were associated with multiple earlier substance use outcomes. Specifically, less sleep was associated with earlier use, intoxication, and repeated use of both alcohol and cannabis. Lower sleep quality was associated with earlier alcohol use, intoxication, and repeated use. Additionally, lower sleep quality was associated with earlier cannabis intoxication and repeated use, but not first use. Both sleep duration and sleep quality in early adolescence may have implications for the development of alcohol and cannabis use throughout adolescence. Further studies to understand the mechanisms linking sleep and substance use are warranted. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Note: An improved solenoid driver valve for miniature shock tubes.

    PubMed

    Lynch, P T

    2016-05-01

    A solenoid driver valve has been built to improve the operating performance of diaphragmless shock tubes, which are used for high pressure, high temperature chemical kinetics, and fluid mechanics studies. For shock tube driver application, the most important characteristics are those of sealing, strength, and quality of the generated shock waves and repeatability of opening characteristics and therefore subsequent post-shock conditions. The main features of the new driver valve are a face o-ring sealing design of the valve, the large internal volume, and through inserts near the solenoid core: adjustable opening characteristics of the valve.

  7. NASA Astrophysics Data System (ADS)

    Tube to tube-sheet joints in heat exchangers are currently welded by the orbital TIG process characterized by very high quality of the weld beads and good repeatability. However, due to high number of welds, a reduction in the welding cycle time would have an interesting impact on manufacturing costs and delays and laser welding technology is aimed to improve this factor. The main disadvantage is the positioning accuracy required by the laser welding process since beam deviations from real joint cause lack of penetration. It is expected that the Orbital laser welding head developed under the European project ORBITAL will avoid this drawback.

  8. Repeatability Evaluation of a Contrast Sensitivity System for Transfer to the Eye Clinic

    NASA Astrophysics Data System (ADS)

    Alcalde, N. G.; Castillo, L. R.; Filgueira, C. Paz; Colombo, E. M.

    2016-04-01

    The Contrast Sensitivity Function (CSF) is a valuable tool which can be used to characterize functional vision and also for the diagnosis and management of patients with different eye diseases. In spite of its usefulness, the CSF is currently hardly ever used in clinical practice. The aim of this study was to validate the use of the system called FVC-100 (Tecnovinc-UNT-CONICET, Argentina), which calculates the CSF, in order to transfer this important tool to ophthalmological clinics. The validation was carried out through the design of a repeatability test and the subsequent analysis of the results. Furthermore, we evaluated the impact of different factors influencing the repeatability of the measurements such as age and previous training. The tests were based on the discrimination of sinusoidal gratings for different spatial frequencies (1, 4 and 12 c/°) in both eyes of 12 people, aged between 20 and 70. The results show that the calculated values of SC of each subject have a high repeatability and are not dependent on age or training. These results allow us to conclude positively regarding the effectiveness of the FVC-100, and to validate its use in clinics for the calculation of the FSC as a standard measure of functional vision quality.

  9. Standardizing evaluation of pQCT image quality in the presence of subject movement: qualitative versus quantitative assessment.

    PubMed

    Blew, Robert M; Lee, Vinson R; Farr, Joshua N; Schiferl, Daniel J; Going, Scott B

    2014-02-01

    Peripheral quantitative computed tomography (pQCT) is an essential tool for assessing bone parameters of the limbs, but subject movement and its impact on image quality remains a challenge to manage. The current approach to determine image viability is by visual inspection, but pQCT lacks a quantitative evaluation. Therefore, the aims of this study were to (1) examine the reliability of a qualitative visual inspection scale and (2) establish a quantitative motion assessment methodology. Scans were performed on 506 healthy girls (9-13 years) at diaphyseal regions of the femur and tibia. Scans were rated for movement independently by three technicians using a linear, nominal scale. Quantitatively, a ratio of movement to limb size (%Move) provided a measure of movement artifact. A repeat-scan subsample (n = 46) was examined to determine %Move's impact on bone parameters. Agreement between measurers was strong (intraclass correlation coefficient = 0.732 for tibia, 0.812 for femur), but greater variability was observed in scans rated 3 or 4, the delineation between repeat and no repeat. The quantitative approach found ≥95% of subjects had %Move <25 %. Comparison of initial and repeat scans by groups above and below 25% initial movement showed significant differences in the >25 % grouping. A pQCT visual inspection scale can be a reliable metric of image quality, but technicians may periodically mischaracterize subject motion. The presented quantitative methodology yields more consistent movement assessment and could unify procedure across laboratories. Data suggest a delineation of 25% movement for determining whether a diaphyseal scan is viable or requires repeat.

  10. Standardizing Evaluation of pQCT Image Quality in the Presence of Subject Movement: Qualitative vs. Quantitative Assessment

    PubMed Central

    Blew, Robert M.; Lee, Vinson R.; Farr, Joshua N.; Schiferl, Daniel J.; Going, Scott B.

    2013-01-01

    Purpose Peripheral quantitative computed tomography (pQCT) is an essential tool for assessing bone parameters of the limbs, but subject movement and its impact on image quality remains a challenge to manage. The current approach to determine image viability is by visual inspection, but pQCT lacks a quantitative evaluation. Therefore, the aims of this study were to (1) examine the reliability of a qualitative visual inspection scale, and (2) establish a quantitative motion assessment methodology. Methods Scans were performed on 506 healthy girls (9–13yr) at diaphyseal regions of the femur and tibia. Scans were rated for movement independently by three technicians using a linear, nominal scale. Quantitatively, a ratio of movement to limb size (%Move) provided a measure of movement artifact. A repeat-scan subsample (n=46) was examined to determine %Move’s impact on bone parameters. Results Agreement between measurers was strong (ICC = .732 for tibia, .812 for femur), but greater variability was observed in scans rated 3 or 4, the delineation between repeat or no repeat. The quantitative approach found ≥95% of subjects had %Move <25%. Comparison of initial and repeat scans by groups above and below 25% initial movement, showed significant differences in the >25% grouping. Conclusions A pQCT visual inspection scale can be a reliable metric of image quality but technicians may periodically mischaracterize subject motion. The presented quantitative methodology yields more consistent movement assessment and could unify procedure across laboratories. Data suggest a delineation of 25% movement for determining whether a diaphyseal scan is viable or requires repeat. PMID:24077875

  11. Genotyping and Molecular Identification of Date Palm Cultivars Using Inter-Simple Sequence Repeat (ISSR) Markers.

    PubMed

    Ayesh, Basim M

    2017-01-01

    Molecular markers are credible for the discrimination of genotypes and estimation of the extent of genetic diversity and relatedness in a set of genotypes. Inter-simple sequence repeat (ISSR) markers rapidly reveal high polymorphic fingerprints and have been used frequently to determine the genetic diversity among date palm cultivars. This chapter describes the application of ISSR markers for genotyping of date palm cultivars. The application involves extraction of genomic DNA from the target cultivars with reliable quality and quantity. Subsequently the extracted DNA serves as a template for amplification of genomic regions flanked by inverted simple sequence repeats using a single primer. The similarity of each pair of samples is measured by calculating the number of mono- and polymorphic bands revealed by gel electrophoresis. Matrices constructed for similarity and genetic distance are used to build a phylogenetic tree and cluster analysis, to determine the molecular relatedness of cultivars. The protocol describes 3 out of 9 tested primers consistently amplified 31 loci in 6 date palm cultivars, with 28 polymorphic loci.

  12. Young investigator challenge: Atypia of undetermined significance in thyroid FNA: Standardized terminology without standardized management--a closer look at repeat FNA and quality measures.

    PubMed

    Brandler, Tamar C; Aziz, Mohamed S; Coutsouvelis, Constantinos; Rosen, Lisa; Rafael, Oana C; Souza, Fabiola; Jelloul, Fatima-Zahra; Klein, Melissa A

    2016-01-01

    The Bethesda system (TBS) for the reporting of thyroid cytopathology established the category of atypia of undetermined significance (AUS) with a 7% target rate and a 5% to 15% implied malignancy risk. Recent literature has reported a broad range of AUS rates, subsequent malignancy rates, and discrepant results from repeat fine-needle aspiration (FNA) versus surgical follow-up. Therefore, this study examined AUS data from the Hofstra North Shore-LIJ School of Medicine to determine the best clinical follow-up. Thyroid aspirates interpreted as AUS in 2012-2014 at the Hofstra North Shore-LIJ School of Medicine were collected. Repeat FNA and surgical follow-up data were tabulated to establish AUS, secondary AUS (diagnosed upon repeat FNA follow-up of a primary FNA AUS diagnosis), atypia of undetermined significance/malignancy (AUS:M) ratios (according to the TBS categories), and malignancy rates for AUS. The AUS rate was 8.5% (976/11,481), and there was follow-up data for 545 cases. The AUS:M ratio was 2.0. Repeat FNA was performed for 281 cases; 57 proceeded to surgical intervention. Repeat FNA reclassified 71.17% of the cases. The malignancy rates for AUS cases proceeding directly to surgery and for those receiving a surgical intervention after a repeat AUS diagnosis were 33.33% and 43.75%, respectively. Repeat FNA resulted in definitive diagnostic reclassification for 67.61% of primary AUS cases and reduced the number of patients triaged to surgery, with 56.58% of the cases recategorized as benign. Cases undergoing surgery after repeat AUS had a higher malignancy rate than those going straight to surgery, and this emphasizes the value of repeat FNA in selecting surgical candidates. In addition, this study highlights the utility of AUS rate monitoring as a quality measure that has contributed to the ability of the Hofstra North Shore-LIJ School of Medicine to adhere closely to TBS recommendations. © 2016 American Cancer Society.

  13. Applicability of refractometry for fast routine checking of hospital preparations.

    PubMed

    Hendrickx, Stijn; Verón, Aurora Monteagudo; Van Schepdael, Ann; Adams, Erwin

    2016-04-30

    Quality control of hospital pharmacy formulations is of the utmost importance to ensure constant quality and to avoid potential mistakes before administration to the patient. In this study we investigated the applicability of refractometry as a fast, inexpensive and easy-to-use quality control measurement. Refractive indices (RI) of a multitude of different hospital formulations with varying concentrations of active compound were measured. The samples consisted of a number of binary aqueous solutions (one compound in water), complex aqueous solutions (multiple compounds in water or in a constant matrix), two suspensions and one emulsion. For all these formulations, linear regression analysis was performed, quality control limits determined and accuracy and repeatability were checked. Subsequently, actual hospital pharmacy samples were analyzed to check whether they were within the specified limits. For both binary and complex aqueous formulations, repeatability was good and a linear correlation for all samples could be observed on condition that the concentration of the active compound was sufficiently high. The refractometer was not sensitive enough for solutions of folic acid and levothyroxine, which had too low a concentration of active compound. Due to lack of homogeneity and light scattering, emulsions and suspensions do not seem suitable for quality control by refractometry. A mathematical equation was generated to predict the refractive index of an aqueous solution containing clonidine HCl as active compound. Values calculated from the equation were compared with measured values and deviations of all samples were found to be lower than 1.3%. In order to use refractometry in a hospital pharmacy for quality control of multicomponent samples, additional intermediate measurements would be required, to overcome the fact that refractometry is not compound specific. In conclusion, we found that refractometry could potentially be useful for daily, fast quality measurements of relatively concentrated binary and more complex aqueous solutions in the hospital pharmacy. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Flying Qualities Evaluation of a Commuter Aircraft With an Ice Contaminated Tailplane

    NASA Technical Reports Server (NTRS)

    Ranaudo, Richard J.; Ratvasky, Thomas P.; FossVanZante, Judith

    2000-01-01

    During the NASA/FAA (Federal Aviation Administration) Tailplane Icing Program, pilot evaluations of aircraft flying qualities were conducted with various ice shapes attached to the horizontal tailplane of the NASA Twin Otter Icing Research Aircraft. Initially, only NASA pilots conducted these evaluations, assessing the differences in longitudinal flight characteristics between the baseline or clean aircraft, and the aircraft configured with an Ice Contaminated Tailplane (ICT). Longitudinal tests included Constant Airspeed Flap Transitions, Constant Airspeed Thrust Transitions, zero-G Pushovers, Repeat Elevator Doublets, and Simulated Approach and Go-Around tasks. Later in the program, guest pilots from government and industry were invited to fly the NASA Twin Otter configured with a single full-span artificial ice shape attached to the leading edge of the horizontal tailplane. This shape represented ice formed due to a 'Failed Boot' condition, and was generated from tests in the Glenn Icing Research Tunnel on a full-scale tailplane model. Guest pilots performed longitudinal handling tests, similar to those conducted by the NASA pilots, to evaluate the ICT condition. In general, all pilots agreed that longitudinal flying qualities were degraded as flaps were lowered, and further degraded at high thrust settings. Repeat elevator doublets demonstrated reduced pitch damping effects due to ICT, which is a characteristic that results in degraded flying qualities. Pilots identified elevator control force reversals (CFR) in zero-G pushovers at a 20 deg flap setting, a characteristic that fails the FAR 25 no CFR certification requirement. However, when the same pilots used the Cooper-Harper rating scale to perform a simulated approach and go-around task at the 20 deg flap setting, they rated the airplane as having Level I and Level II flying qualities respectively. By comparison, the same task conducted at the 30 deg flap setting, resulted in Level II flying qualities for the approach portion, and Level III for the go-around portion.The results of this program indicate that safe and acceptable flying qualities with an ICT condition, can be effectively assessed by task-oriented pilot maneuvers. In addition, other maneuvers such as repeat elevator doublets provide good qualitative and quantitative assessments of pitch damping and elevator effectiveness, which are characteristics that correlate well with pilot task ratings. The results of this testing indicate that the FAR 25 zero-G pushover maneuver, which requires no CFR during its execution, may be an overly conservative pass/fail criteria for aircraft certification.

  15. ABISM: an interactive image quality assessment tool for adaptive optics instruments

    NASA Astrophysics Data System (ADS)

    Girard, Julien H.; Tourneboeuf, Martin

    2016-07-01

    ABISM (Automatic Background Interactive Strehl Meter) is a interactive tool to evaluate the image quality of astronomical images. It works on seeing-limited point spread functions (PSF) but was developed in particular for diffraction-limited PSF produced by adaptive optics (AO) systems. In the VLT service mode (SM) operations framework, ABISM is designed to help support astronomers or telescope and instruments operators (TIOs) to quickly measure the Strehl ratio (SR) during or right after an observing block (OB) to evaluate whether it meets the requirements/predictions or whether is has to be repeated and will remain in the SM queue. It's a Python-based tool with a graphical user interface (GUI) that can be used with little AO knowledge. The night astronomer (NA) or Telescope and Instrument Operator (TIO) can launch ABISM in one click and the program is able to read keywords from the FITS header to avoid mistakes. A significant effort was also put to make ABISM as robust (and forgiven) with a high rate of repeatability. As a matter of fact, ABISM is able to automatically correct for bad pixels, eliminate stellar neighbours and estimate/fit properly the background, etc.

  16. Characterization of Three Maize Bacterial Artificial Chromosome Libraries toward Anchoring of the Physical Map to the Genetic Map Using High-Density Bacterial Artificial Chromosome Filter Hybridization1

    PubMed Central

    Yim, Young-Sun; Davis, Georgia L.; Duru, Ngozi A.; Musket, Theresa A.; Linton, Eric W.; Messing, Joachim W.; McMullen, Michael D.; Soderlund, Carol A.; Polacco, Mary L.; Gardiner, Jack M.; Coe, Edward H.

    2002-01-01

    Three maize (Zea mays) bacterial artificial chromosome (BAC) libraries were constructed from inbred line B73. High-density filter sets from all three libraries, made using different restriction enzymes (HindIII, EcoRI, and MboI, respectively), were evaluated with a set of complex probes including the185-bp knob repeat, ribosomal DNA, two telomere-associated repeat sequences, four centromere repeats, the mitochondrial genome, a multifragment chloroplast DNA probe, and bacteriophage λ. The results indicate that the libraries are of high quality with low contamination by organellar and λ-sequences. The use of libraries from multiple enzymes increased the chance of recovering each region of the genome. Ninety maize restriction fragment-length polymorphism core markers were hybridized to filters of the HindIII library, representing 6× coverage of the genome, to initiate development of a framework for anchoring BAC contigs to the intermated B73 × Mo17 genetic map and to mark the bin boundaries on the physical map. All of the clones used as hybridization probes detected at least three BACs. Twenty-two single-copy number core markers identified an average of 7.4 ± 3.3 positive clones, consistent with the expectation of six clones. This information is integrated into fingerprinting data generated by the Arizona Genomics Institute to assemble the BAC contigs using fingerprint contig and contributed to the process of physical map construction. PMID:12481051

  17. The flight test of Pi-SAR(L) for the repeat-pass interferometric SAR

    NASA Astrophysics Data System (ADS)

    Nohmi, Hitoshi; Shimada, Masanobu; Miyawaki, Masanori

    2006-09-01

    This paper describes the experiment of the repeat pass interferometric SAR using Pi-SAR(L). The air-borne repeat-pass interferometric SAR is expected as an effective method to detect landslide or predict a volcano eruption. To obtain a high-quality interferometric image, it is necessary to make two flights on the same flight pass. In addition, since the antenna of the Pi-SAR(L) is secured to the aircraft, it is necessary to fly at the same drift angle to keep the observation direction same. We built a flight control system using an auto pilot which has been installed in the airplane. This navigation system measures position and altitude precisely with using a differential GPS, and the PC Navigator outputs a difference from the desired course to the auto pilot. Since the air density is thinner and the speed is higher than the landing situation, the gain of the control system is required to be adjusted during the repeat pass flight. The observation direction could be controlled to some extent by adjusting a drift angle with using a flight speed control. The repeat-pass flight was conducted in Japan for three days in late November. The flight was stable and the deviation was within a few meters for both horizontal and vertical direction even in the gusty condition. The SAR data were processed in time domain based on range Doppler algorism to make the complete motion compensation. Thus, the interferometric image processed after precise phase compensation is shown.

  18. Evaluation of Physicochemical Deterioration and Lipid Oxidation of Beef Muscle Affected by Freeze-thaw Cycles

    PubMed Central

    Rahman, M. H.; Hossain, M. M.; Rahman, S. M. E.; Amin, M. R.; Oh, Deog-Hwan

    2015-01-01

    This study was performed to explore the deterioration of physicochemical quality of beef hind limb during frozen storage at −20℃, affected by repeated freeze-thaw cycles. The effects of three successive freeze-thaw cycles on beef hind limb were investigated comparing with unfrozen beef muscle for 80 d by keeping at −20±1℃. The freeze-thaw cycles were subjected to three thawing methods and carried out to select the best one on the basis of deterioration of physicochemical properties of beef. As the number of repeated freeze-thaw cycles increased, drip loss decreased and water holding capacity (WHC) increased (p<0.05) till two cycles and then decreased. Cooking loss increased in cycle one and three but decreased in cycle two. Moreover, drip loss, WHC and cooking loss affected (p<0.05) by thawing methods within the cycles. However, pH value decreased (p<0.05), but peroxide value (p<0.05), free fatty acids value (p<0.05) and TBARS value increased (p<0.05) significantly as the number of repeated freeze-thaw cycles increased. Moreover, significant (p<0.05) interactive effects were found among the thawing methods and repeated cycles. As a result, freeze-thaw cycles affected the physicochemical quality of beef muscle, causing the degradation of its quality. PMID:26877637

  19. Near common-path optical fiber interferometer for potentially fast on-line microscale-nanoscale surface measurement

    NASA Astrophysics Data System (ADS)

    Jiang, Xiangqian; Wang, Kaiwei; Martin, Haydn

    2006-12-01

    We introduce a new surface measurement method for potential online application. Compared with our previous research, the new design is a significant improvement. It also features high stability because it uses a near common-path configuration. The method should be of great benefit to advanced manufacturing, especially for quality and process control in ultraprecision manufacturing and on the production line. Proof-of-concept experiments have been successfully conducted by measuring the system repeatability and the displacements of a mirror surface.

  20. Binary classification of items of interest in a repeatable process

    DOEpatents

    Abell, Jeffrey A; Spicer, John Patrick; Wincek, Michael Anthony; Wang, Hui; Chakraborty, Debejyo

    2015-01-06

    A system includes host and learning machines. Each machine has a processor in electrical communication with at least one sensor. Instructions for predicting a binary quality status of an item of interest during a repeatable process are recorded in memory. The binary quality status includes passing and failing binary classes. The learning machine receives signals from the at least one sensor and identifies candidate features. Features are extracted from the candidate features, each more predictive of the binary quality status. The extracted features are mapped to a dimensional space having a number of dimensions proportional to the number of extracted features. The dimensional space includes most of the passing class and excludes at least 90 percent of the failing class. Received signals are compared to the boundaries of the recorded dimensional space to predict, in real time, the binary quality status of a subsequent item of interest.

  1. CRISPR recognition tool (CRT): a tool for automatic detection of clustered regularly interspaced palindromic repeats.

    PubMed

    Bland, Charles; Ramsey, Teresa L; Sabree, Fareedah; Lowe, Micheal; Brown, Kyndall; Kyrpides, Nikos C; Hugenholtz, Philip

    2007-06-18

    Clustered Regularly Interspaced Palindromic Repeats (CRISPRs) are a novel type of direct repeat found in a wide range of bacteria and archaea. CRISPRs are beginning to attract attention because of their proposed mechanism; that is, defending their hosts against invading extrachromosomal elements such as viruses. Existing repeat detection tools do a poor job of identifying CRISPRs due to the presence of unique spacer sequences separating the repeats. In this study, a new tool, CRT, is introduced that rapidly and accurately identifies CRISPRs in large DNA strings, such as genomes and metagenomes. CRT was compared to CRISPR detection tools, Patscan and Pilercr. In terms of correctness, CRT was shown to be very reliable, demonstrating significant improvements over Patscan for measures precision, recall and quality. When compared to Pilercr, CRT showed improved performance for recall and quality. In terms of speed, CRT proved to be a huge improvement over Patscan. Both CRT and Pilercr were comparable in speed, however CRT was faster for genomes containing large numbers of repeats. In this paper a new tool was introduced for the automatic detection of CRISPR elements. This tool, CRT, showed some important improvements over current techniques for CRISPR identification. CRT's approach to detecting repetitive sequences is straightforward. It uses a simple sequential scan of a DNA sequence and detects repeats directly without any major conversion or preprocessing of the input. This leads to a program that is easy to describe and understand; yet it is very accurate, fast and memory efficient, being O(n) in space and O(nm/l) in time.

  2. CRISPR Recognition Tool (CRT): a tool for automatic detection ofclustered regularly interspaced palindromic repeats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bland, Charles; Ramsey, Teresa L.; Sabree, Fareedah

    Clustered Regularly Interspaced Palindromic Repeats (CRISPRs) are a novel type of direct repeat found in a wide range of bacteria and archaea. CRISPRs are beginning to attract attention because of their proposed mechanism; that is, defending their hosts against invading extrachromosomal elements such as viruses. Existing repeat detection tools do a poor job of identifying CRISPRs due to the presence of unique spacer sequences separating the repeats. In this study, a new tool, CRT, is introduced that rapidly and accurately identifies CRISPRs in large DNA strings, such as genomes and metagenomes. CRT was compared to CRISPR detection tools, Patscan andmore » Pilercr. In terms of correctness, CRT was shown to be very reliable, demonstrating significant improvements over Patscan for measures precision, recall and quality. When compared to Pilercr, CRT showed improved performance for recall and quality. In terms of speed, CRT also demonstrated superior performance, especially for genomes containing large numbers of repeats. In this paper a new tool was introduced for the automatic detection of CRISPR elements. This tool, CRT, was shown to be a significant improvement over the current techniques for CRISPR identification. CRT's approach to detecting repetitive sequences is straightforward. It uses a simple sequential scan of a DNA sequence and detects repeats directly without any major conversion or preprocessing of the input. This leads to a program that is easy to describe and understand; yet it is very accurate, fast and memory efficient, being O(n) in space and O(nm/l) in time.« less

  3. Measuring service quality and its relationship to future consumer behavior.

    PubMed

    Headley, D E; Miller, S J

    1993-01-01

    The authors adapt the SERVQUAL scale for medical care services and examine it for reliability, dimensionality, and validity in a primary care clinic setting. In addition, they explore the possibility of a link between perceived service quality--and its various dimensions--and a patient's future intent to complain, compliment, repeat purchase, and switch providers. Findings from 159 matched-pair responses indicate that the SERVQUAL scale can be adapted reliably to a clinic setting and that the dimensions of reliability, dependability, and empathy are most predictive of a patient's intent to complain, compliment, repeat purchase, and switch providers.

  4. An audit of rejected repeated x-ray films as a quality assurance element in a radiology department.

    PubMed

    Eze, K C; Omodia, N; Okegbunam, B; Adewonyi, T; Nzotta, C C

    2008-12-01

    To find out the causes, number, percentage and sizes of rejected radiographic films with a view of adopting measures that will reduce the rate and number of rejected films. Radiology Department of a University Teaching Hospital. Over a two-year period (1st April 2002 to 31st March 2004), the total number of x-ray films utilized for radiographic examinations, rejected films and sizes of rejected films were collected retrospectively from the medical record of radiology department. All the rejected films were viewed by a radiologist and three radiographers for the causes of the rejects which was arrived at by consensus. The data was analysed. A total of 15,095 films were used in the study period and 1,338 films (8.86%) were rejected or wasted. The rate of rejected films varied from 7.69% to 13.82% with average of 8.86%. The greatest cause of film rejects was radiographers' faults 547 (40.88%), followed by equipments faults 255 (19.06%), and patients' faults 250 (18.90%). The highest reject rate (13.82%) was for films used for examination of the spine (15 x 30) cm size. This is followed by 9.92% for skull (18 x 24) cm films and 8.83% for small sized films (24 x 30) cm used for paediatric patients. Of a total of 1,338 rejected films, 1276 (95.37%) additional exposure were done to obtain the basic desired diagnostic information involving 1151 patients; 885 (76.89%) of these patients needed at least one additional hospital visit to take the repeat exposure. Rejected films are not billable; patients receive additional radiation and may even come to hospital in another day for the repeat. Radiographer's work is increased as well as that of the support staff. The waiting room may be congested and waiting time increased. The cost of processing chemical and films are increased, thus if work is quantified in monetary terms, the cost of repeats is high. Rejected-repeated film analysis is cheap, simple, practicable, easy to interpret and an effective indictor of quality assurance of radiology departments.

  5. Frequency selection rule for high definition and high frame rate Lissajous scanning.

    PubMed

    Hwang, Kyungmin; Seo, Yeong-Hyeon; Ahn, Jinhyo; Kim, Pilhan; Jeong, Ki-Hun

    2017-10-26

    Lissajous microscanners are very attractive in compact laser scanning applications such as endomicroscopy or pro-projection display owing to high mechanical stability and low operating voltages. The scanning frequency serves as a critical factor for determining the scanning imaging quality. Here we report the selection rule of scanning frequencies that can realize high definition and high frame-rate (HDHF) full-repeated Lissajous scanning imaging. The fill factor (FF) monotonically increases with the total lobe number of a Lissajous curve, i.e., the sum of scanning frequencies divided by the great common divisor (GCD) of bi-axial scanning frequencies. The frames per second (FPS), called the pattern repeated rate or the frame rate, linearly increases with GCD. HDHF Lissajous scanning is achieved at the bi-axial scanning frequencies, where the GCD has the maximum value among various sets of the scanning frequencies satisfying the total lobe number for a target FF. Based on this selection rule, the experimental results clearly demonstrate that conventional Lissajous scanners substantially increase both FF and FPS by slightly modulating the scanning frequencies at near the resonance within the resonance bandwidth of a Lissajous scanner. This selection rule provides a new guideline for HDHF Lissajous scanning in compact laser scanning systems.

  6. High-quality de novo assembly of the apple genome and methylome dynamics of early fruit development.

    PubMed

    Daccord, Nicolas; Celton, Jean-Marc; Linsmith, Gareth; Becker, Claude; Choisne, Nathalie; Schijlen, Elio; van de Geest, Henri; Bianco, Luca; Micheletti, Diego; Velasco, Riccardo; Di Pierro, Erica Adele; Gouzy, Jérôme; Rees, D Jasper G; Guérif, Philippe; Muranty, Hélène; Durel, Charles-Eric; Laurens, François; Lespinasse, Yves; Gaillard, Sylvain; Aubourg, Sébastien; Quesneville, Hadi; Weigel, Detlef; van de Weg, Eric; Troggio, Michela; Bucher, Etienne

    2017-07-01

    Using the latest sequencing and optical mapping technologies, we have produced a high-quality de novo assembly of the apple (Malus domestica Borkh.) genome. Repeat sequences, which represented over half of the assembly, provided an unprecedented opportunity to investigate the uncharacterized regions of a tree genome; we identified a new hyper-repetitive retrotransposon sequence that was over-represented in heterochromatic regions and estimated that a major burst of different transposable elements (TEs) occurred 21 million years ago. Notably, the timing of this TE burst coincided with the uplift of the Tian Shan mountains, which is thought to be the center of the location where the apple originated, suggesting that TEs and associated processes may have contributed to the diversification of the apple ancestor and possibly to its divergence from pear. Finally, genome-wide DNA methylation data suggest that epigenetic marks may contribute to agronomically relevant aspects, such as apple fruit development.

  7. Arctic Digital Elevation Models (DEMs) generated by Surface Extraction from TIN-Based Searchspace Minimization (SETSM) algorithm from RPCs-based Imagery

    NASA Astrophysics Data System (ADS)

    Noh, M. J.; Howat, I. M.; Porter, C. C.; Willis, M. J.; Morin, P. J.

    2016-12-01

    The Arctic is undergoing rapid change associated with climate warming. Digital Elevation Models (DEMs) provide critical information for change measurement and infrastructure planning in this vulnerable region, yet the existing quality and coverage of DEMs in the Arctic is poor. Low contrast and repeatedly-textured surfaces, such as snow and glacial ice and mountain shadows, all common in the Arctic, challenge existing stereo-photogrammetric techniques. Submeter resolution, stereoscopic satellite imagery with high geometric and radiometric quality, and wide spatial coverage are becoming increasingly accessible to the scientific community. To utilize these imagery for extracting DEMs at a large scale over glaciated and high latitude regions we developed the Surface Extraction from TIN-based Searchspace Minimization (SETSM) algorithm. SETSM is fully automatic (i.e. no search parameter settings are needed) and uses only the satellite rational polynomial coefficients (RPCs). Using SETSM, we have generated a large number of DEMs (> 100,000 scene pair) from WorldView, GeoEye and QuickBird stereo images collected by DigitalGlobe Inc. and archived by the Polar Geospatial Center (PGC) at the University of Minnesota through an academic licensing program maintained by the US National Geospatial-Intelligence Agency (NGA). SETSM is the primary DEM generation software for the US National Science Foundation's ArcticDEM program, with the objective of generating high resolution (2-8m) topography for the entire Arctic landmass, including seamless DEM mosaics and repeat DEM strips for change detection. ArcticDEM is collaboration between multiple US universities, governmental agencies and private companies, as well as international partners assisting with quality control and registration. ArcticDEM is being produced using the petascale Blue Waters supercomputer at the National Center for Supercomputer Applications at the University of Illinois. In this paper, we introduce the SETSM algorithm and the processing system used for the ArcticDEM project, as well as provide notable examples of ArcticDEM products.

  8. The influence of steaming and a ratio of grated coconut to water on the yield and quality of virgin coconut oil

    NASA Astrophysics Data System (ADS)

    Rahmah, N. L.; Istikoma, R.; Kumalaningsih, S.

    2018-03-01

    The quality of Virgin Coconut Oil (VCO) is determined by the quality of coconut milk. High quality of coconut milk can be obtained by proper handling of grated coconut as raw material. When coconut was shredded, the lipases are exposed which can hydrolyse the oil resulting free fatty acid (FFA).Steaming is a technique to inactivate lipases. In addition, a ratio of grated coconut to water and steaming duration are important factor to the VCO extraction. Therefore, this study aimed to obtain the best combination of steaming duration and suitable ratio of grated coconut to water in order to produce high quality VCO. The research design was Factorial Randomized Block Design consisted of 2 factors: steaming duration (5; 10; and 15 minutes) and grated coconut to water ratio (1:0; 1:1; 1:2; 1:3; and 1:4 w/v),each treatment was repeated twice. Parameters analyzed were FFA, moisture content, and yield values. The result showed that the best treatment was a treatment with 15 minutes steaming of grated coconut and 1:4 ratio of grated coconut to water. The best treatment VCO had characteristic as follows: FFA 0.054 %, moisture content 0.129 % and yield 17.563 %.

  9. Air quality and exercise-induced bronchoconstriction in elite athletes.

    PubMed

    Rundell, Kenneth W; Sue-Chu, Malcolm

    2013-08-01

    A higher prevalence of airway hyperresponsiveness, airway remodeling, and asthma has been identified among athletes who compete and train in environmental conditions of cold dry air and/or high air pollution. Repeated long-duration exposure to cold/dry air at high minute ventilation rates can cause airway damage. Competition or training at venues close to busy roadways, or in indoor ice arenas or chlorinated swimming pools, harbors a risk for acute and chronic airway disorders from high pollutant exposure. This article discusses the effects of these harsh environments on the airways, and summarizes potential mechanisms and prevalence of airway disorders in elite athletes. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Measuring Customer Satisfaction and Quality of Service in Special Libraries.

    ERIC Educational Resources Information Center

    White, Marilyn Domas; Abels, Eileen G.; Nitecki, Danuta

    This project tested the appropriateness of SERVQUAL (i.e., an instrument widely used in the service industry for assessing service quality based on repeated service encounters rather than a particular service encounter) to measure service quality in special libraries and developed a modified version for special libraries. SERVQUAL is based on an…

  11. Assessing the Quality of Parent-Teacher Relationships for Students with ADHD

    ERIC Educational Resources Information Center

    Mautone, Jennifer A.; Marcelle, Enitan; Tresco, Katy E.; Power, Thomas J.

    2015-01-01

    Family involvement in education, including the quality of family-school communication, has been demonstrated repeatedly to have a substantial effect on child development and success in school; however, measures of this construct are limited. The purpose this study was to examine the factor structure and concurrent validity of the Quality of the…

  12. High-speed and low-power repeater for VLSI interconnects

    NASA Astrophysics Data System (ADS)

    Karthikeyan, A.; Mallick, P. S.

    2017-10-01

    This paper proposes a repeater for boosting the speed of interconnects with low power dissipation. We have designed and implemented at 45 and 32 nm technology nodes. Delay and power dissipation performances are analyzed for various voltage levels at these technology nodes using Spice simulations. A significant reduction in delay and power dissipation are observed compared to a conventional repeater. The results show that the proposed high-speed low-power repeater has a reduced delay for higher load capacitance. The proposed repeater is also compared with LPTG CMOS repeater, and the results shows that the proposed repeater has reduced delay. The proposed repeater can be suitable for high-speed global interconnects and has the capacity to drive large loads.

  13. Development of a 0.5m clear aperture Cassegrain type collimator telescope

    NASA Astrophysics Data System (ADS)

    Ekinci, Mustafa; Selimoǧlu, Özgür

    2016-07-01

    Collimator is an optical instrument used to evaluate performance of high precision instruments, especially space-born high resolution telescopes. Optical quality of the collimator telescope needs to be better than the instrument to be measured. This requirement leads collimator telescope to be a very precise instrument with high quality mirrors and a stable structure to keep it operational under specified conditions. In order to achieve precision requirements and to ensure repeatability of the mounts for polishing and metrology, opto-mechanical principles are applied to mirror mounts. Finite Element Method is utilized to simulate gravity effects, integration errors and temperature variations. Finite element analyses results of deformed optical surfaces are imported to optical domain by using Zernike polynomials to evaluate the design against specified WFE requirements. Both mirrors are aspheric and made from Zerodur for its stability and near zero CTE, M1 is further light-weighted. Optical quality measurements of the mirrors are achieved by using custom made CGHs on an interferometric test setup. Spider of the Cassegrain collimator telescope has a flexural adjustment mechanism driven by precise micrometers to overcome tilt errors originating from finite stiffness of the structure and integration errors. Collimator telescope is assembled and alignment methods are proposed.

  14. Repeat film analysis and its implications for quality assurance in dental radiology: An institutional case study

    PubMed Central

    Acharya, Shruthi; Pai, Keerthilatha M.; Acharya, Shashidhar

    2015-01-01

    Context: The goal of any radiologist is to produce the highest quality diagnostic radiographs, while keeping patient exposure as low as reasonably achievable (ALARA). Aims: The aim of this study was to describe the reasons for radiograph rejections through a repeat film analysis in an Indian dental school. Settings and Design: An observational study conducted in the Department of Oral Medicine and Radiology, Manipal College of Dental Sciences, Manipal. Materials and Methods: During a 6-month study period, a total of 9,495 intra-oral radiographs and 2339 extraoral radiographs taken in the Radiology Department were subjected to repeat film analysis. Statistical Analysis Used: SPSS Version 16. Descriptive analysis used. Results: The results showed that the repeat rates were 7.1% and 5.86% for intraoral and extraoral radiographs, respectively. Among the causes for errors reported, positioning error (38.7%) was the most common, followed by improper angulations (26.1%), and improper film placement (11.2%) for intra-oral radiographs. The study found that the maximum frequency of repeats among extraoral radiographs was for panoramic radiographs (49%) followed by lateral cephalogram (33%), and paranasal sinus view (14%). It was also observed that repeat rate of intraoral radiographs was highest for internees (44.7%), and undergraduate students (28.2%). Conclusions: The study pointed to a need for more targeted interventions to achieve the goal of keeping patient exposure ALARA in a dental school setting. PMID:26321841

  15. Does a quality management system improve quality in primary care practices in Switzerland? A longitudinal study

    PubMed Central

    Goetz, Katja; Hess, Sigrid; Jossen, Marianne; Huber, Felix; Rosemann, Thomas; Brodowski, Marc; Künzi, Beat; Szecsenyi, Joachim

    2015-01-01

    Objectives To examine the effectiveness of the quality management programme—European Practice Assessment—in primary care in Switzerland. Design Longitudinal study with three points of measurement. Setting Primary care practices in Switzerland. Participants In total, 45 of 91 primary care practices completed European Practice Assessment three times. Outcomes The interval between each assessment was around 36 months. A variance analyses for repeated measurements were performed for all 129 quality indicators from the domains: ‘infrastructure’, ‘information’, ‘finance’, and ‘quality and safety’ to examine changes over time. Results Significant improvements were found in three of four domains: ‘quality and safety’ (F=22.81, p<0.01), ‘information’ (F=27.901, p<0.01) and ‘finance’ (F=4.073, p<0.02). The 129 quality indicators showed a significant improvement within the three points of measurement (F=33.864, p<0.01). Conclusions The European Practice Assessment for primary care practices thus provides a functioning quality management programme, focusing on the sustainable improvement of structural and organisational aspects to promote high quality of primary care. The implementation of a quality management system which also includes a continuous improvement process would give added value to provide good care. PMID:25900466

  16. Optimization of b-value distribution for biexponential diffusion-weighted MR imaging of normal prostate.

    PubMed

    Jambor, Ivan; Merisaari, Harri; Aronen, Hannu J; Järvinen, Jukka; Saunavaara, Jani; Kauko, Tommi; Borra, Ronald; Pesola, Marko

    2014-05-01

    To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. Optimal b-value distributions for the fit of three parameters (fast diffusion Df, slow diffusion Ds, and fraction of fast diffusion f) were determined using Monte-Carlo simulations. The optimal b-value distribution was calculated using four individual optimization methods. Eight healthy volunteers underwent four repeated 3 Tesla prostate DWI scans using both 16 equally distributed b-values and an optimized b-value distribution obtained from the simulations. The b-value distributions were compared in terms of measurement reliability and repeatability using Shrout-Fleiss analysis. Using low noise levels, the optimal b-value distribution formed three separate clusters at low (0-400 s/mm2), mid-range (650-1200 s/mm2), and high b-values (1700-2000 s/mm2). Higher noise levels resulted into less pronounced clustering of b-values. The clustered optimized b-value distribution demonstrated better measurement reliability and repeatability in Shrout-Fleiss analysis compared with 16 equally distributed b-values. The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments. Copyright © 2013 Wiley Periodicals, Inc.

  17. Effect of e-learning and repeated performance feedback on spirometry test quality in family practice: a cluster trial.

    PubMed

    Schermer, Tjard R; Akkermans, Reinier P; Crockett, Alan J; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W; Pieters, Willem

    2011-01-01

    Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices.

  18. Measurement properties of continuous text reading performance tests.

    PubMed

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for reproducibility and repeatability studies. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  19. Verification of intensity modulated profiles using a pixel segmented liquid-filled linear array.

    PubMed

    Pardo, J; Roselló, J V; Sánchez-Doblado, F; Gómez, F

    2006-06-07

    A liquid isooctane (C8H18) filled ionization chamber linear array developed for radiotherapy quality assurance, consisting of 128 pixels (each of them with a 1.7 mm pitch), has been used to acquire profiles of several intensity modulated fields. The results were compared with film measurements using the gamma test. The comparisons show a very good matching, even in high gradient dose regions. The volume-averaging effect of the pixels is negligible and the spatial resolution is enough to verify these regions. However, some mismatches between the detectors have been found in regions where low-energy scattered photons significantly contribute to the total dose. These differences are not very important (in fact, the measurements of both detectors are in agreement using the gamma test with tolerances of 3% and 3 mm in most of those regions), and may be associated with the film energy dependence. In addition, the linear array repeatability (0.27% one standard deviation) is much better than the film one ( approximately 3%). The good repeatability, small pixel size and high spatial resolution make the detector ideal for the real time profile verification of high gradient beam profiles like those present in intensity modulated radiation therapy and radiosurgery.

  20. Automatic orbital GTAW welding: Highest quality welds for tomorrow's high-performance systems

    NASA Technical Reports Server (NTRS)

    Henon, B. K.

    1985-01-01

    Automatic orbital gas tungsten arc welding (GTAW) or TIG welding is certain to play an increasingly prominent role in tomorrow's technology. The welds are of the highest quality and the repeatability of automatic weldings is vastly superior to that of manual welding. Since less heat is applied to the weld during automatic welding than manual welding, there is less change in the metallurgical properties of the parent material. The possibility of accurate control and the cleanliness of the automatic GTAW welding process make it highly suitable to the welding of the more exotic and expensive materials which are now widely used in the aerospace and hydrospace industries. Titanium, stainless steel, Inconel, and Incoloy, as well as, aluminum can all be welded to the highest quality specifications automatically. Automatic orbital GTAW equipment is available for the fusion butt welding of tube-to-tube, as well as, tube to autobuttweld fittings. The same equipment can also be used for the fusion butt welding of up to 6 inch pipe with a wall thickness of up to 0.154 inches.

  1. Scanners for analytic print measurement: the devil in the details

    NASA Astrophysics Data System (ADS)

    Zeise, Eric K.; Williams, Don; Burns, Peter D.; Kress, William C.

    2007-01-01

    Inexpensive and easy-to-use linear and area-array scanners have frequently substituted as colorimeters and densitometers for low-frequency (i.e., large area) hard copy image measurement. Increasingly, scanners are also being used for high spatial frequency, image microstructure measurements, which were previously reserved for high performance microdensitometers. In this paper we address characteristics of flatbed reflection scanners in the evaluation of print uniformity, geometric distortion, geometric repeatability and the influence of scanner MTF and noise on analytic measurements. Suggestions are made for the specification and evaluation of scanners to be used in print image quality standards that are being developed.

  2. High-Throughput Sequencing and De Novo Assembly of the Isatis indigotica Transcriptome

    PubMed Central

    Tang, Xiaoqing; Xiao, Yunhua; Lv, Tingting; Wang, Fangquan; Zhu, QianHao; Zheng, Tianqing; Yang, Jie

    2014-01-01

    Background Isatis indigotica, the source of the traditional Chinese medicine Radix isatidis (Ban-Lan-Gen), is an extremely important economical crop in China. To facilitate biological, biochemical and molecular research on the medicinal chemicals in I. indigotica, here we report the first I. indigotica transcriptome generated by RNA sequencing (RNA-seq). Results RNA-seq library was created using RNA extracted from a mixed sample including leaf and root. A total of 33,238 unigenes were assembled from more than 28 million of high quality short reads. The quality of the assembly was experimentally examined by cDNA sequencing of seven randomly selected unigenes. Based on blast search 28,184 unigenes had a hit in at least one of the protein and nucleotide databases used in this study, and 8 unigenes were found to be associated with biosynthesis of indole and its derivatives. According to Gene Ontology classification, 22,365 unigenes were categorized into 48 functional groups. Furthermore, Clusters of Orthologous Group and Swiss-Port annotation were assigned for 7,707 and 18,679 unigenes, respectively. Analysis of repeat motifs identified 6,400 simple sequence repeat markers in 4,509 unigenes. Conclusion Our data provide a comprehensive sequence resource for molecular study of I. indigotica. Our results will facilitate studies on the functions of genes involved in the indole alkaloid biosynthesis pathway and on metabolism of nitrogen and indole alkaloids in I. indigotica and its related species. PMID:25259890

  3. Discovery and mapping of a new expressed sequence tag-single nucleotide polymorphism and simple sequence repeat panel for large-scale genetic studies and breeding of Theobroma cacao L.

    PubMed Central

    Allegre, Mathilde; Argout, Xavier; Boccara, Michel; Fouet, Olivier; Roguet, Yolande; Bérard, Aurélie; Thévenin, Jean Marc; Chauveau, Aurélie; Rivallan, Ronan; Clement, Didier; Courtois, Brigitte; Gramacho, Karina; Boland-Augé, Anne; Tahi, Mathias; Umaharan, Pathmanathan; Brunel, Dominique; Lanaud, Claire

    2012-01-01

    Theobroma cacao is an economically important tree of several tropical countries. Its genetic improvement is essential to provide protection against major diseases and improve chocolate quality. We discovered and mapped new expressed sequence tag-single nucleotide polymorphism (EST-SNP) and simple sequence repeat (SSR) markers and constructed a high-density genetic map. By screening 149 650 ESTs, 5246 SNPs were detected in silico, of which 1536 corresponded to genes with a putative function, while 851 had a clear polymorphic pattern across a collection of genetic resources. In addition, 409 new SSR markers were detected on the Criollo genome. Lastly, 681 new EST-SNPs and 163 new SSRs were added to the pre-existing 418 co-dominant markers to construct a large consensus genetic map. This high-density map and the set of new genetic markers identified in this study are a milestone in cocoa genomics and for marker-assisted breeding. The data are available at http://tropgenedb.cirad.fr. PMID:22210604

  4. Fabrication of Thermoplastic Composite Laminates Having Film Interleaves By Automated Fiber Placement

    NASA Technical Reports Server (NTRS)

    Hulcher, A. B.; Tiwari, S. N.; Marchello, J. M.; Johnston, Norman J. (Technical Monitor)

    2001-01-01

    Experiments were carried out at the NASA Langley Research Center automated Fiber placement facility to determine an optimal process for the fabrication of composite materials having polymer film interleaves. A series of experiments was conducted to determine an optimal process for the composite prior to investigation of a process to fabricate laminates with polymer films. The results of the composite tests indicated that a well-consolidated, void-free laminate could be attained. Preliminary interleaf processing trials were then conducted to establish some broad guidelines for film processing. The primary finding of these initial studies was that a two-stage process was necessary in order to process these materials adequately. A screening experiment was then performed to determine the relative influence of the process variables on the quality of the film interface as determined by the wedge peel test method. Parameters that were found to be of minor influence on specimen quality were subsequently held at fixed values enabling a more rapid determination of an optimal process. Optimization studies were then performed by varying the remaining parameters at three film melt processing rates. The resulting peel data were fitted with quadratic response surfaces. Additional specimens were fabricated at levels of high peel strength as predicted by the regression models in an attempt to gage the accuracy of the predicted response and to assess the repeatability of the process. The overall results indicate that quality laminates having film interleaves can be successfully and repeatably fabricated by automated fiber placement.

  5. First Insights into the Large Genome of Epimedium sagittatum (Sieb. et Zucc) Maxim, a Chinese Traditional Medicinal Plant

    PubMed Central

    Liu, Di; Zeng, Shao-Hua; Chen, Jian-Jun; Zhang, Yan-Jun; Xiao, Gong; Zhu, Lin-Yao; Wang, Ying

    2013-01-01

    Epimedium sagittatum (Sieb. et Zucc) Maxim is a member of the Berberidaceae family of basal eudicot plants, widely distributed and used as a traditional medicinal plant in China for therapeutic effects on many diseases with a long history. Recent data shows that E. sagittatum has a relatively large genome, with a haploid genome size of ~4496 Mbp, divided into a small number of only 12 diploid chromosomes (2n = 2x = 12). However, little is known about Epimedium genome structure and composition. Here we present the analysis of 691 kb of high-quality genomic sequence derived from 672 randomly selected plasmid clones of E. sagittatum genomic DNA, representing ~0.0154% of the genome. The sampled sequences comprised at least 78.41% repetitive DNA elements and 2.51% confirmed annotated gene sequences, with a total GC% content of 39%. Retrotransposons represented the major class of transposable element (TE) repeats identified (65.37% of all TE repeats), particularly LTR (Long Terminal Repeat) retrotransposons (52.27% of all TE repeats). Chromosome analysis and Fluorescence in situ Hybridization of Gypsy-Ty3 retrotransposons were performed to survey the E. sagittatum genome at the cytological level. Our data provide the first insights into the composition and structure of the E. sagittatum genome, and will facilitate the functional genomic analysis of this valuable medicinal plant. PMID:23807511

  6. Food cost disparities in rural communities.

    PubMed

    Hardin-Fanning, Frances; Rayens, Mary Kay

    2015-05-01

    Promotion of healthy eating is an effective public health strategy to prevent chronic disease incidence and progression. However, food prices can impede healthy eating, especially in rural communities. The purpose of this study was to determine whether food costs are associated with nutritional quality, geographic location, and month of year. The Overall Nutritional Quality Index and cost of 92 foods were assessed four times over a 10-month period in the primary grocery stores in four Kentucky counties, two rural and two urban. Repeated measures analysis of variance was used to assess differences in food costs by nutritional quality, county, and month. Among more nutritious food items, costs were lower in urban areas. This was particularly true among foods in the highest quartile of nutritional quality. Across all counties, there was a pattern of highest per-serving costs in the second quartile of nutritional quality, whereas more nutritious foods were less expensive. Strategies that help individuals improve the ability to identify and prepare less costly foods with high nutritional value may be effective in improving dietary habits, particularly in rural, impoverished food deserts. © 2014 Society for Public Health Education.

  7. Food Cost Disparities in Rural Communities

    PubMed Central

    Hardin-Fanning, Frances; Rayens, Mary Kay

    2015-01-01

    Promotion of healthy eating is an effective public health strategy to prevent chronic disease incidence and progression. However, food prices can impede healthy eating, especially in rural communities. The purpose of this study was to determine whether food costs are associated with nutritional quality, geographic location, and month of year. The Overall Nutritional Quality Index and cost of 92 foods were assessed four times over a 10-month period in the primary grocery stores in four Kentucky counties, two rural and two urban. Repeated measures analysis of variance was used to assess differences in food costs by nutritional quality, county, and month. Among more nutritious food items, costs were lower in urban areas. This was particularly true among foods in the highest quartile of nutritional quality. Across all counties, there was a pattern of highest per-serving costs in the second quartile of nutritional quality, whereas more nutritious foods were less expensive. Strategies that help individuals improve the ability to identify and prepare less costly foods with high nutritional value may be effective in improving dietary habits, particularly in rural, impoverished food deserts. PMID:25305093

  8. A proteomics performance standard to support measurement quality in proteomics.

    PubMed

    Beasley-Green, Ashley; Bunk, David; Rudnick, Paul; Kilpatrick, Lisa; Phinney, Karen

    2012-04-01

    The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Improving Software Quality and Management Through Use of Service Level Agreements

    DTIC Science & Technology

    2005-03-01

    many who believe that the quality of the development process is the best predictor of software product quality. ( Fenton ) Repeatable software processes...reduced errors per KLOC for small projects ( Fenton ), and the quality management metric (QMM) (Machniak, Osmundson). There are also numerous IEEE 14...attention to cosmetic user interface issues and any problems that may arise with the prototype. (Sawyer) The validation process is also another check

  10. Acute Care Use for Ambulatory Care-Sensitive Conditions in High-Cost Users of Medical Care with Mental Illness and Addictions.

    PubMed

    Hensel, Jennifer M; Taylor, Valerie H; Fung, Kinwah; Yang, Rebecca; Vigod, Simone N

    2018-01-01

    The role of mental illness and addiction in acute care use for chronic medical conditions that are sensitive to ambulatory care management requires focussed attention. This study examines how mental illness or addiction affects risk for repeat hospitalization and/or emergency department use for ambulatory care-sensitive conditions (ACSCs) among high-cost users of medical care. A retrospective, population-based cohort study using data from Ontario, Canada. Among the top 10% of medical care users ranked by cost, we determined rates of any and repeat care use (hospitalizations and emergency department [ED] visits) between April 1, 2011, and March 31, 2012, for 14 consensus established ACSCs and compared them between those with and without diagnosed mental illness or addiction during the 2 years prior. Risk ratios were adjusted (aRR) for age, sex, residence, and income quintile. Among 314,936 high-cost users, 35.9% had a mental illness or addiction. Compared to those without, individuals with mental illness or addiction were more likely to have an ED visit or hospitalization for any ACSC (22.8% vs. 19.6%; aRR, 1.21; 95% confidence interval [CI], 1.20-1.23). They were also more likely to have repeat ED visits or hospitalizations for the same ACSC (6.2% vs. 4.4% of those without; aRR, 1.48; 95% CI, 1.44-1.53). These associations were stronger in stratifications by mental illness diagnostic subgroup, particularly for those with a major mental illness. The presence of mental illness and addiction among high-cost users of medical services may represent an unmet need for quality ambulatory and primary care.

  11. Intra-Platform Repeatability and Inter-Platform Comparability of MicroRNA Microarray Technology

    PubMed Central

    Sato, Fumiaki; Tsuchiya, Soken; Terasawa, Kazuya; Tsujimoto, Gozoh

    2009-01-01

    Over the last decade, DNA microarray technology has provided a great contribution to the life sciences. The MicroArray Quality Control (MAQC) project demonstrated the way to analyze the expression microarray. Recently, microarray technology has been utilized to analyze a comprehensive microRNA expression profiling. Currently, several platforms of microRNA microarray chips are commercially available. Thus, we compared repeatability and comparability of five different microRNA microarray platforms (Agilent, Ambion, Exiqon, Invitrogen and Toray) using 309 microRNAs probes, and the Taqman microRNA system using 142 microRNA probes. This study demonstrated that microRNA microarray has high intra-platform repeatability and comparability to quantitative RT-PCR of microRNA. Among the five platforms, Agilent and Toray array showed relatively better performances than the others. However, the current lineup of commercially available microRNA microarray systems fails to show good inter-platform concordance, probably because of lack of an adequate normalization method and severe divergence in stringency of detection call criteria between different platforms. This study provided the basic information about the performance and the problems specific to the current microRNA microarray systems. PMID:19436744

  12. The effect of image alignment on capillary blood flow measurement of the neuroretinal rim using the Heidelberg retina flowmeter

    PubMed Central

    Sehi, M; Flanagan, J G

    2004-01-01

    Aim: To examine the influence of image alignment on the repeatability of blood flow measurements of the optic nerve. Methods: 10 normal subjects were examined. Heidelberg retina tomograph imaging was performed to establish best location and focus for the temporal neuroretinal rim. Two high quality Heidelberg retina flowmeter (HRF) images were acquired for three methods of alignment: central, nasal, and temporal. A 10×10 pixel measurement window was selected and exactly reproduced on all images. The interquartile pixel values were used to calculate capillary flow. ANOVA, intraclass correlation coefficients (ICC) and the coefficient of repeatability (CoR) were used for analysis. Results: There was no difference between methods (p = 0.47) or between visits (p = 0.51). The ICCs were 0.83 for the central, 0.34 for the nasal, and 0.42 for the temporal alignment. The CoR was 31.5 for central (mean effect 235.1), 234.6 for nasal, and 256.7 for temporal alignment. Conclusion: Central alignment was the most repeatable method for the measurement of neuroretinal rim capillary blood flow using the HRF. PMID:14736775

  13. Self-reported confidence in recall as a predictor of validity and repeatability of physical activity questionnaire data.

    PubMed

    Cust, Anne E; Armstrong, Bruce K; Smith, Ben J; Chau, Josephine; van der Ploeg, Hidde P; Bauman, Adrian

    2009-05-01

    Self-reported confidence ratings have been used in other research disciplines as a tool to assess data quality, and may be useful in epidemiologic studies. We examined whether self-reported confidence in recall of physical activity was a predictor of the validity and retest reliability of physical activity measures from the European Prospective Investigation into Cancer and Nutrition (EPIC) past-year questionnaire and the International Physical Activity Questionnaire (IPAQ) last-7-day questionnaire.During 2005-2006 in Sydney, Australia, 97 men and 80 women completed both questionnaires at baseline and at 10 months and wore an accelerometer as an objective comparison measure for three 7-day periods during the same timeframe. Participants rated their confidence in recalling physical activity for each question using a 5-point scale and were dichotomized at the median confidence value. Participants in the high-confidence group had higher validity and repeatability coefficients than those in the low-confidence group for most comparisons. The differences were most apparent for validity of IPAQ moderate activity: Spearman correlation rho = 0.34 (95% confidence interval [CI] = 0.08 to 0.55) and 0.01 (-0.17 to 0.20) for high- and low-confidence groups, respectively; and repeatability of EPIC household activity: rho = 0.81 (0.72 to 0.87) and 0.63 (0.48 to 0.74), respectively, and IPAQ vigorous activity: rho = 0.58 (0.43 to 0.70) and 0.29 (0.07 to 0.49), respectively. Women were less likely than men to report high recall confidence of past-year activity (adjusted odds ratio = 0.38; 0.18 to 0.80). Confidence ratings could be useful as indicators of recall accuracy (ie, validity and repeatability) of physical activity measures, and possibly for detecting differential measurement error and identifying questionnaire items that require improvement.

  14. Direct infusion mass spectrometry metabolomics dataset: a benchmark for data processing and quality control

    PubMed Central

    Kirwan, Jennifer A; Weber, Ralf J M; Broadhurst, David I; Viant, Mark R

    2014-01-01

    Direct-infusion mass spectrometry (DIMS) metabolomics is an important approach for characterising molecular responses of organisms to disease, drugs and the environment. Increasingly large-scale metabolomics studies are being conducted, necessitating improvements in both bioanalytical and computational workflows to maintain data quality. This dataset represents a systematic evaluation of the reproducibility of a multi-batch DIMS metabolomics study of cardiac tissue extracts. It comprises of twenty biological samples (cow vs. sheep) that were analysed repeatedly, in 8 batches across 7 days, together with a concurrent set of quality control (QC) samples. Data are presented from each step of the workflow and are available in MetaboLights. The strength of the dataset is that intra- and inter-batch variation can be corrected using QC spectra and the quality of this correction assessed independently using the repeatedly-measured biological samples. Originally designed to test the efficacy of a batch-correction algorithm, it will enable others to evaluate novel data processing algorithms. Furthermore, this dataset serves as a benchmark for DIMS metabolomics, derived using best-practice workflows and rigorous quality assessment. PMID:25977770

  15. Response of Vibrio fischeri to repeated exposures over time in an Online Toxicity Monitor

    EPA Science Inventory

    Online Toxicity Monitors have been developed to provide continuous, time-relevant information regarding water quality. These systems measure a physiological or behavioral response of a sentinel organism to changes water quality. One such system, the Microlan Toxcontrol, is base...

  16. Evolution of Protein Domain Repeats in Metazoa

    PubMed Central

    Schüler, Andreas; Bornberg-Bauer, Erich

    2016-01-01

    Repeats are ubiquitous elements of proteins and they play important roles for cellular function and during evolution. Repeats are, however, also notoriously difficult to capture computationally and large scale studies so far had difficulties in linking genetic causes, structural properties and evolutionary trajectories of protein repeats. Here we apply recently developed methods for repeat detection and analysis to a large dataset comprising over hundred metazoan genomes. We find that repeats in larger protein families experience generally very few insertions or deletions (indels) of repeat units but there is also a significant fraction of noteworthy volatile outliers with very high indel rates. Analysis of structural data indicates that repeats with an open structure and independently folding units are more volatile and more likely to be intrinsically disordered. Such disordered repeats are also significantly enriched in sites with a high functional potential such as linear motifs. Furthermore, the most volatile repeats have a high sequence similarity between their units. Since many volatile repeats also show signs of recombination, we conclude they are often shaped by concerted evolution. Intriguingly, many of these conserved yet volatile repeats are involved in host-pathogen interactions where they might foster fast but subtle adaptation in biological arms races. Key Words: protein evolution, domain rearrangements, protein repeats, concerted evolution. PMID:27671125

  17. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    PubMed Central

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P < 0.001; and 0.94 for magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  18. The missing indels: an estimate of indel variation in a human genome and analysis of factors that impede detection

    PubMed Central

    Jiang, Yue; Turinsky, Andrei L.; Brudno, Michael

    2015-01-01

    With the development of High-Throughput Sequencing (HTS) thousands of human genomes have now been sequenced. Whenever different studies analyze the same genome they usually agree on the amount of single-nucleotide polymorphisms, but differ dramatically on the number of insertion and deletion variants (indels). Furthermore, there is evidence that indels are often severely under-reported. In this manuscript we derive the total number of indel variants in a human genome by combining data from different sequencing technologies, while assessing the indel detection accuracy. Our estimate of approximately 1 million indels in a Yoruban genome is much higher than the results reported in several recent HTS studies. We identify two key sources of difficulties in indel detection: the insufficient coverage, read length or alignment quality; and the presence of repeats, including short interspersed elements and homopolymers/dimers. We quantify the effect of these factors on indel detection. The quality of sequencing data plays a major role in improving indel detection by HTS methods. However, many indels exist in long homopolymers and repeats, where their detection is severely impeded. The true number of indel events is likely even higher than our current estimates, and new techniques and technologies will be required to detect them. PMID:26130710

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glawe, Andrea; Eggerath, Daniel; Schäfer, Frank

    The market of Large Area Organic Printed Electronics is developing rapidly to increase efficiency and quality as well as to lower costs further. Applications for OPV, OLED, RFID and compact Printed Electronic systems are increasing. In order to make the final products more affordable, but at the same time highly accurate, Roll to Roll (R2R) production on flexible transparent polymer substrates is the way forward. There are numerous printing and coating technologies suitable depending on the design, the product application and the chemical process technology. Mainly the product design (size, pattern, repeatability) defines the application technology.

  20. Augmentation of Quick-EXAFS measurement facility at the energy scanning EXAFS beamline at INDUS-2 SRS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poswal, A. K., E-mail: poswalashwini@gmail.com; Agrawal, Ankur; Bhattachryya, D.

    2015-06-24

    In this paper implementation of Quick-EXAFS data acquisition facility at the Energy Scanning EXAFS beamline(BL-09) at INDUS-2 synchrotron source, Indore is presented. By adopting a continuous-scan mode in the Double Crystal monochromator (DCM), a high signal-to-noise ratio is maintained and the acquisition time is reduced to few seconds. The quality of spectra and repeatability is checked by measuring standards. The present mode of data acquisition would enable EXAFS measurement for in-situ studies even in fluorescence mode.

  1. Mesh quality control for multiply-refined tetrahedral grids

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Strawn, Roger

    1994-01-01

    A new algorithm for controlling the quality of multiply-refined tetrahedral meshes is presented in this paper. The basic dynamic mesh adaption procedure allows localized grid refinement and coarsening to efficiently capture aerodynamic flow features in computational fluid dynamics problems; however, repeated application of the procedure may significantly deteriorate the quality of the mesh. Results presented show the effectiveness of this mesh quality algorithm and its potential in the area of helicopter aerodynamics and acoustics.

  2. Integrating Epidemiology, Education, and Organizing for Environmental Justice: Community Health Effects of Industrial Hog Operations

    PubMed Central

    Wing, Steve; Horton, Rachel Avery; Muhammad, Naeema; Grant, Gary R.; Tajik, Mansoureh; Thu, Kendall

    2008-01-01

    The environmental justice movement has stimulated community-driven research about the living and working conditions of people of color and low-income communities. We describe an epidemiological study designed to link research with community education and organizing for social justice. In eastern North Carolina, high-density industrial swine production occurs in communities of low-income people and people of color. We investigated relationships between the resulting pollution and the health and quality of life of the hog operations’ neighbors. A repeat-measures longitudinal design, community involvement in data collection, and integration of qualitative and quantitative research methods helped promote data quality while providing opportunities for community education and organizing. Research could affect policy through its findings and its mobilization of communities. PMID:18556620

  3. Metrologies for quantitative nanomechanical testing and quality control in semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Pratt, Jon R.; Kramar, John A.; Newell, David B.; Smith, Douglas T.

    2005-05-01

    If nanomechanical testing is to evolve into a tool for process and quality control in semiconductor fabrication, great advances in throughput, repeatability, and accuracy of the associated instruments and measurements will be required. A recent grant awarded by the NIST Advanced Technology Program seeks to address the throughput issue by developing a high-speed AFM-based platform for quantitative nanomechanical measurements. The following paper speaks to the issue of quantitative accuracy by presenting an overview of various standards and techniques under development at NIST and other national metrology institutes (NMIs) that can provide a metrological basis for nanomechanical testing. The infrastructure we describe places firm emphasis on traceability to the International System of Units, paving the way for truly quantitative, rather than qualitative, physical property testing.

  4. The impact of repeat-testing of common chemistry analytes at critical concentrations.

    PubMed

    Onyenekwu, Chinelo P; Hudson, Careen L; Zemlin, Annalise E; Erasmus, Rajiv T

    2014-12-01

    Early notification of critical values by the clinical laboratory to the treating physician is a requirement for accreditation and is essential for effective patient management. Many laboratories automatically repeat a critical value before reporting it to prevent possible misdiagnosis. Given today's advanced instrumentation and quality assurance practices, we questioned the validity of this approach. We performed an audit of repeat-testing in our laboratory to assess for significant differences between initial and repeated test results, estimate the delay caused by repeat-testing and to quantify the cost of repeating these assays. A retrospective audit of repeat-tests for sodium, potassium, calcium and magnesium in the first quarter of 2013 at Tygerberg Academic Laboratory was conducted. Data on the initial and repeat-test values and the time that they were performed was extracted from our laboratory information system. The Clinical Laboratory Improvement Amendment criteria for allowable error were employed to assess for significant difference between results. A total of 2308 repeated tests were studied. There was no significant difference in 2291 (99.3%) of the samples. The average delay ranged from 35 min for magnesium to 42 min for sodium and calcium. At least 2.9% of laboratory running costs for the analytes was spent on repeating them. The practice of repeating a critical test result appears unnecessary as it yields similar results, delays notification to the treating clinician and increases laboratory running costs.

  5. Mass Manufacturing Challenges For CPV Primary And Secondary Optics

    NASA Astrophysics Data System (ADS)

    Luce, Thomas; Cohen, Joel

    2010-10-01

    Crucial for the performance and longevity of CPV installations is the efficiency of the optics used. Low production cost and high performance are key for the economical success of a CPV concept. To be able to compete with existing energy sources, proven mass production methods as well as high performance materials have to be employed. The injection molding process is the ideal serial production process capable to deliver at the same time high part quantities, excellent part precision and repeatable part quality at low manufacturing cost. Primary and secondary optics require different materials to be applied. The Pros and Cons of these materials in terms of production properties and achievable part precision will be discussed. We will show quality results for primary Fresnel optics using PMMA and, alternatively Silicone on Glass. For secondary optics we will demonstrate the use of optical silicone lenses widely used for high power LED applications today. Optical grade silicone has an excellent environmental stability even when encountering high energy density levels. The experience of Eschenbach Optik in injection molding silicone optics shows that this material is a very cost competitive alternative for glass secondary optics providing both highest optical performance and precision.

  6. An atomic-scale and high efficiency finishing method of zirconia ceramics by using magnetorheological finishing

    NASA Astrophysics Data System (ADS)

    Luo, Hu; Guo, Meijian; Yin, Shaohui; Chen, Fengjun; Huang, Shuai; Lu, Ange; Guo, Yuanfan

    2018-06-01

    Zirconia ceramics is a valuable crucial material for fabricating functional components applied in aerospace, biology, precision machinery, military industry and other fields. However, the properties of its high brittleness and high hardness could seriously reduce its finishing efficiency and surface quality by conventional processing technology. In this work, we present a high efficiency and high-quality finishing process by using magnetorheological finishing (MRF), which employs the permanent magnetic yoke with straight air gap as excitation unit. The sub-nanoscale surface roughness and damage free surface can be obtained after magnetorheological finishing. The XRD results and SEM morphologies confirmed that the mechanical shear removal with ductile modes are the dominant material removal mechanism for the magnetorheological finishing of zirconia ceramic. With the developed experimental apparatus, the effects of workpiece speed, trough speed and work gap on material removal rate and surface roughness were systematically investigated. Zirconia ceramics finished to ultra-smooth surface with surface roughness less than Ra 1 nm was repeatedly achieved during the parametric experiments. Additionally, the highest material removal rate exceeded 1 mg/min when using diamond as an abrasive particle. Magnetorheological finishing promises to be an adaptable and efficient method for zirconia ceramics finishing.

  7. Automated daily quality control analysis for mammography in a multi-unit imaging center.

    PubMed

    Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli

    2018-01-01

    Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

  8. Does a quality management system improve quality in primary care practices in Switzerland? A longitudinal study.

    PubMed

    Goetz, Katja; Hess, Sigrid; Jossen, Marianne; Huber, Felix; Rosemann, Thomas; Brodowski, Marc; Künzi, Beat; Szecsenyi, Joachim

    2015-04-21

    To examine the effectiveness of the quality management programme--European Practice Assessment--in primary care in Switzerland. Longitudinal study with three points of measurement. Primary care practices in Switzerland. In total, 45 of 91 primary care practices completed European Practice Assessment three times. The interval between each assessment was around 36 months. A variance analyses for repeated measurements were performed for all 129 quality indicators from the domains: 'infrastructure', 'information', 'finance', and 'quality and safety' to examine changes over time. Significant improvements were found in three of four domains: 'quality and safety' (F=22.81, p<0.01), 'information' (F=27.901, p<0.01) and 'finance' (F=4.073, p<0.02). The 129 quality indicators showed a significant improvement within the three points of measurement (F=33.864, p<0.01). The European Practice Assessment for primary care practices thus provides a functioning quality management programme, focusing on the sustainable improvement of structural and organisational aspects to promote high quality of primary care. The implementation of a quality management system which also includes a continuous improvement process would give added value to provide good care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. And, not or: Quality, quantity in scientific publishing

    PubMed Central

    Allesina, Stefano

    2017-01-01

    Scientists often perceive a trade-off between quantity and quality in scientific publishing: finite amounts of time and effort can be spent to produce few high-quality papers or subdivided to produce many papers of lower quality. Despite this perception, previous studies have indicated the opposite relationship, in which productivity (publishing more papers) is associated with increased paper quality (usually measured by citation accumulation). We examine this question in a novel way, comparing members of the National Academy of Sciences with themselves across years, and using a much larger dataset than previously analyzed. We find that a member’s most highly cited paper in a given year has more citations in more productive years than in in less productive years. Their lowest cited paper each year, on the other hand, has fewer citations in more productive years. To disentangle the effect of the underlying distributions of citations and productivities, we repeat the analysis for hypothetical publication records generated by scrambling each author’s citation counts among their publications. Surprisingly, these artificial histories re-create the above trends almost exactly. Put another way, the observed positive relationship between quantity and quality can be interpreted as a consequence of randomly drawing citation counts for each publication: more productive years yield higher-cited papers because they have more chances to draw a large value. This suggests that citation counts, and the rewards that have come to be associated with them, may be more stochastic than previously appreciated. PMID:28570567

  10. Genome-Wide Association Study for Muscle Fat Content and Abdominal Fat Traits in Common Carp (Cyprinus carpio)

    PubMed Central

    Zheng, Xianhu; Kuang, Youyi; Lv, Weihua; Cao, Dingchen; Sun, Zhipeng; Sun, Xiaowen

    2016-01-01

    Muscle fat content is an important phenotypic trait in fish, as it affects the nutritional, technical and sensory qualities of flesh. To identify loci and candidate genes associated with muscle fat content and abdominal fat traits, we performed a genome-wide association study (GWAS) using the common carp 250 K SNP assay in a common carp F2 resource population. A total of 18 loci surpassing the genome-wide suggestive significance level were detected for 4 traits: fat content in dorsal muscle (MFdo), fat content in abdominal muscle (MFab), abdominal fat weight (AbFW), and AbFW as a percentage of eviscerated weight (AbFP). Among them, one SNP (carp089419) affecting both AbFW and AbFP reached the genome-wide significance level. Ten of those loci were harbored in or near known genes. Furthermore, relative expressions of 5 genes related to MFdo were compared using dorsal muscle samples with high and low phenotypic values. The results showed that 4 genes were differentially expressed between the high and low phenotypic groups. These genes are, therefore, prospective candidate genes for muscle fat content: ankyrin repeat domain 10a (ankrd10a), tetratricopeptide repeat, ankyrin repeat and coiled-coil containing 2 (tanc2), and four jointed box 1 (fjx1) and choline kinase alpha (chka). These results offer valuable insights into the complex genetic basis of fat metabolism and deposition. PMID:28030623

  11. Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

    DOE PAGES

    Birch, Gabriel C.; Woo, Bryana L.; Sanchez, Andres L.; ...

    2017-08-24

    The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical opticalmore » quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.« less

  12. Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birch, Gabriel C.; Woo, Bryana L.; Sanchez, Andres L.

    The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical opticalmore » quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.« less

  13. Methods for sequencing GC-rich and CCT repeat DNA templates

    DOEpatents

    Robinson, Donna L.

    2007-02-20

    The present invention is directed to a PCR-based method of cycle sequencing DNA and other polynucleotide sequences having high CG content and regions of high GC content, and includes for example DNA strands with a high Cytosine and/or Guanosine content and repeated motifs such as CCT repeats.

  14. Comparative analysis of tandem repeats from hundreds of species reveals unique insights into centromere evolution.

    PubMed

    Melters, Daniël P; Bradnam, Keith R; Young, Hugh A; Telis, Natalie; May, Michael R; Ruby, J Graham; Sebra, Robert; Peluso, Paul; Eid, John; Rank, David; Garcia, José Fernando; DeRisi, Joseph L; Smith, Timothy; Tobias, Christian; Ross-Ibarra, Jeffrey; Korf, Ian; Chan, Simon W L

    2013-01-30

    Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes.

  15. Comparative analysis of tandem repeats from hundreds of species reveals unique insights into centromere evolution

    PubMed Central

    2013-01-01

    Background Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Results Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. Conclusions While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes. PMID:23363705

  16. Full field image reconstruction is suitable for high-pitch dual-source computed tomography.

    PubMed

    Mahnken, Andreas H; Allmendinger, Thomas; Sedlmair, Martin; Tamm, Miriam; Reinartz, Sebastian D; Flohr, Thomas

    2012-11-01

    The field of view (FOV) in high-pitch dual-source computed tomography (DSCT) is limited by the size of the second detector. The goal of this study was to develop and evaluate a full FOV image reconstruction technique for high-pitch DSCT. For reconstruction beyond the FOV of the second detector, raw data of the second system were extended to the full dimensions of the first system, using the partly existing data of the first system in combination with a very smooth transition weight function. During the weighted filtered backprojection, the data of the second system were applied with an additional weighting factor. This method was tested for different pitch values from 1.5 to 3.5 on a simulated phantom and on 25 high-pitch DSCT data sets acquired at pitch values of 1.6, 2.0, 2.5, 2.8, and 3.0. Images were reconstructed with FOV sizes of 260 × 260 and 500 × 500 mm. Image quality was assessed by 2 radiologists using a 5-point Likert scale and analyzed with repeated-measure analysis of variance. In phantom and patient data, full FOV image quality depended on pitch. Where complete projection data from both tube-detector systems were available, image quality was unaffected by pitch changes. Full FOV image quality was not compromised at pitch values of 1.6 and remained fully diagnostic up to a pitch of 2.0. At higher pitch values, there was an increasing difference in image quality between limited and full FOV images (P = 0.0097). With this new image reconstruction technique, full FOV image reconstruction can be used up to a pitch of 2.0.

  17. Experimental entanglement purification of arbitrary unknown states.

    PubMed

    Pan, Jian-Wei; Gasparoni, Sara; Ursin, Rupert; Weihs, Gregor; Zeilinger, Anton

    2003-05-22

    Distribution of entangled states between distant locations is essential for quantum communication over large distances. But owing to unavoidable decoherence in the quantum communication channel, the quality of entangled states generally decreases exponentially with the channel length. Entanglement purification--a way to extract a subset of states of high entanglement and high purity from a large set of less entangled states--is thus needed to overcome decoherence. Besides its important application in quantum communication, entanglement purification also plays a crucial role in error correction for quantum computation, because it can significantly increase the quality of logic operations between different qubits. Here we demonstrate entanglement purification for general mixed states of polarization-entangled photons using only linear optics. Typically, one photon pair of fidelity 92% could be obtained from two pairs, each of fidelity 75%. In our experiments, decoherence is overcome to the extent that the technique would achieve tolerable error rates for quantum repeaters in long-distance quantum communication. Our results also imply that the requirement of high-accuracy logic operations in fault-tolerant quantum computation can be considerably relaxed.

  18. Odor measurements according to EN 13725: A statistical analysis of variance components

    NASA Astrophysics Data System (ADS)

    Klarenbeek, Johannes V.; Ogink, Nico W. M.; van der Voet, Hilko

    2014-04-01

    In Europe, dynamic olfactometry, as described by the European standard EN 13725, has become the preferred method for evaluating odor emissions emanating from industrial and agricultural sources. Key elements of this standard are the quality criteria for trueness and precision (repeatability). Both are linked to standard values of n-butanol in nitrogen. It is assumed in this standard that whenever a laboratory complies with the overall sensory quality criteria for n-butanol, the quality level is transferable to other, environmental, odors. Although olfactometry is well established, little has been done to investigate inter laboratory variance (reproducibility). Therefore, the objective of this study was to estimate the reproducibility of odor laboratories complying with EN 13725 as well as to investigate the transferability of n-butanol quality criteria to other odorants. Based upon the statistical analysis of 412 odor measurements on 33 sources, distributed in 10 proficiency tests, it was established that laboratory, panel and panel session are components of variance that significantly differ between n-butanol and other odorants (α = 0.05). This finding does not support the transferability of the quality criteria, as determined on n-butanol, to other odorants and as such is a cause for reconsideration of the present single reference odorant as laid down in EN 13725. In case of non-butanol odorants, repeatability standard deviation (sr) and reproducibility standard deviation (sR) were calculated to be 0.108 and 0.282 respectively (log base-10). The latter implies that the difference between two consecutive single measurements, performed on the same testing material by two or more laboratories under reproducibility conditions, will not be larger than a factor 6.3 in 95% of cases. As far as n-butanol odorants are concerned, it was found that the present repeatability standard deviation (sr = 0.108) compares favorably to that of EN 13725 (sr = 0.172). It is therefore suggested that the repeatability limit (r), as laid down in EN 13725, can be reduced from r ≤ 0.477 to r ≤ 0.31.

  19. Molecular Beam Epitaxy of lithium niobium oxide multifunctional materials

    NASA Astrophysics Data System (ADS)

    Tellekamp, M. Brooks; Shank, Joshua C.; Doolittle, W. Alan

    2017-04-01

    The role of stoichiometry and growth temperature in the preferential nucleation of material phases in the Li-Nb-O family are explored yielding an empirical growth phase diagram. It is shown that while single parameter variation often produces multi-phase films, combining substrate temperature control with the previously published lithium flux limited growth allows the repeatable growth of high quality single crystalline films of many different oxide phases. Higher temperatures (800-1050 °C) than normally used in MBE were necessary to achieve high quality materials. At these temperatures the desorption of surface species is shown to play an important role in film composition. Using this method single phase films of NbO, NbO2, LiNbO2, Li3NbO4, LiNbO3, and LiNb3O8 have been achieved in the same growth system, all on c-plane sapphire. Finally, the future of these films in functional oxide heterostructures is briefly discussed.

  20. Genetic and geochemical signatures to prevent frauds and counterfeit of high-quality asparagus and pistachio.

    PubMed

    Zannella, Carmela; Carucci, Francesca; Aversano, Riccardo; Prohaska, Thomas; Vingiani, Simona; Carputo, Domenico; Adamo, Paola

    2017-12-15

    A fingerprinting strategy based on genetic (simple sequence repeat) and geochemical (multielement and 87 Sr/ 86 Sr ratio) analysis was tested to prove the geographical origin of high-quality Italian products "White Asparagus from Bassano del Grappa" and "Green Pistachio from Bronte". Genetic analysis generated many polymorphic alleles and different specific amplified fragments in both agriproducts. In addition, a core set of markers was defined. According to variability within production soils and products, potential candidate elements linking asparagus (Zn, P, Cr, Mg, B, K) and pistachio (Mn, P, Cr, Mg, Ti, B, K, Sc, S) to the production areas were identified. The Sr isotopic signature was an excellent marker when Italian asparagus was compared with literature data for Hungarian and Peruvian asparagus. This work reinforces the use of Sr isotope composition in the soil bioavailable fraction, as assessed by 1mol/L NH 4 NO 3 , to distinguish white asparagus and pistachio originating from different geographical areas. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High-throughput STR analysis for DNA database using direct PCR.

    PubMed

    Sim, Jeong Eun; Park, Su Jeong; Lee, Han Chul; Kim, Se-Yong; Kim, Jong Yeol; Lee, Seung Hwan

    2013-07-01

    Since the Korean criminal DNA database was launched in 2010, we have focused on establishing an automated DNA database profiling system that analyzes short tandem repeat loci in a high-throughput and cost-effective manner. We established a DNA database profiling system without DNA purification using a direct PCR buffer system. The quality of direct PCR procedures was compared with that of conventional PCR system under their respective optimized conditions. The results revealed not only perfect concordance but also an excellent PCR success rate, good electropherogram quality, and an optimal intra/inter-loci peak height ratio. In particular, the proportion of DNA extraction required due to direct PCR failure could be minimized to <3%. In conclusion, the newly developed direct PCR system can be adopted for automated DNA database profiling systems to replace or supplement conventional PCR system in a time- and cost-saving manner. © 2013 American Academy of Forensic Sciences Published 2013. This article is a U.S. Government work and is in the public domain in the U.S.A.

  2. Assembling short reads from jumping libraries with large insert sizes.

    PubMed

    Vasilinetc, Irina; Prjibelski, Andrey D; Gurevich, Alexey; Korobeynikov, Anton; Pevzner, Pavel A

    2015-10-15

    Advances in Next-Generation Sequencing technologies and sample preparation recently enabled generation of high-quality jumping libraries that have a potential to significantly improve short read assemblies. However, assembly algorithms have to catch up with experimental innovations to benefit from them and to produce high-quality assemblies. We present a new algorithm that extends recently described exSPAnder universal repeat resolution approach to enable its applications to several challenging data types, including jumping libraries generated by the recently developed Illumina Nextera Mate Pair protocol. We demonstrate that, with these improvements, bacterial genomes often can be assembled in a few contigs using only a single Nextera Mate Pair library of short reads. Described algorithms are implemented in C++ as a part of SPAdes genome assembler, which is freely available at bioinf.spbau.ru/en/spades. ap@bioinf.spbau.ru Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  4. Repeat associated mechanisms of genome evolution and function revealed by the Mus caroli and Mus pahari genomes

    PubMed Central

    Thybert, David; Roller, Maša; Navarro, Fábio C.P.; Fiddes, Ian; Streeter, Ian; Feig, Christine; Martin-Galvez, David; Kolmogorov, Mikhail; Janoušek, Václav; Akanni, Wasiu; Aken, Bronwen; Aldridge, Sarah; Chakrapani, Varshith; Chow, William; Clarke, Laura; Cummins, Carla; Doran, Anthony; Dunn, Matthew; Goodstadt, Leo; Howe, Kerstin; Howell, Matthew; Josselin, Ambre-Aurore; Karn, Robert C.; Laukaitis, Christina M.; Jingtao, Lilue; Martin, Fergal; Muffato, Matthieu; Nachtweide, Stefanie; Quail, Michael A.; Sisu, Cristina; Stanke, Mario; Stefflova, Klara; Van Oosterhout, Cock; Veyrunes, Frederic; Ward, Ben; Yang, Fengtang; Yazdanifar, Golbahar; Zadissa, Amonida; Adams, David J.; Brazma, Alvis; Gerstein, Mark; Paten, Benedict; Pham, Son; Keane, Thomas M.; Odom, Duncan T.; Flicek, Paul

    2018-01-01

    Understanding the mechanisms driving lineage-specific evolution in both primates and rodents has been hindered by the lack of sister clades with a similar phylogenetic structure having high-quality genome assemblies. Here, we have created chromosome-level assemblies of the Mus caroli and Mus pahari genomes. Together with the Mus musculus and Rattus norvegicus genomes, this set of rodent genomes is similar in divergence times to the Hominidae (human-chimpanzee-gorilla-orangutan). By comparing the evolutionary dynamics between the Muridae and Hominidae, we identified punctate events of chromosome reshuffling that shaped the ancestral karyotype of Mus musculus and Mus caroli between 3 and 6 million yr ago, but that are absent in the Hominidae. Hominidae show between four- and sevenfold lower rates of nucleotide change and feature turnover in both neutral and functional sequences, suggesting an underlying coherence to the Muridae acceleration. Our system of matched, high-quality genome assemblies revealed how specific classes of repeats can play lineage-specific roles in related species. Recent LINE activity has remodeled protein-coding loci to a greater extent across the Muridae than the Hominidae, with functional consequences at the species level such as reproductive isolation. Furthermore, we charted a Muridae-specific retrotransposon expansion at unprecedented resolution, revealing how a single nucleotide mutation transformed a specific SINE element into an active CTCF binding site carrier specifically in Mus caroli, which resulted in thousands of novel, species-specific CTCF binding sites. Our results show that the comparison of matched phylogenetic sets of genomes will be an increasingly powerful strategy for understanding mammalian biology. PMID:29563166

  5. Development and evaluation of the nurse quality of communication with patient questionnaire.

    PubMed

    Vuković, Mira; Gvozdenović, Branislav S; Stamatović-Gajić, Branka; Ilić, Miodrag; Gajić, Tomislav

    2010-01-01

    Nurse/patient relationship as a complex interrelation or as an interaction of the factor patient and factor nurse has been a subject of a number of studies during the past ten years. Nurse/patient communication is a special entity, usually observed within a framework of the wider nurse/patient relationship. In that regard, we wanted to develop a standardized questionnaire that could reliably measure the quality of communication between nurse and patient, and be used by nurses. The main goal of this study was to develop and evaluate construct validity of the Nurse Quality of Communication with Patient Questionnaire (NQCPQ), as well as to evaluate its reliability. The goal was also to establish a measure of inter-raters reliability, using two repeated measurements of results by items and scores of the NQCPQ, on the same observed units by two assessors. The starting NQCPQ that consists of 25 items, was filled in by two groups of nurses. Each nurse was questioned during morning and afternoon shifts, in order to evaluate their communication with hospitalized patients, using marks from 1 to 6. To evaluate construct validity, we used the analysis of main components, while reliability was assessed using intraclass correlation coefficient and Cronbach-alpha coefficient. To evaluate interraters reliability, we used Pearson correlation coefficient. Using a group of 118 patients, we explained 86% of the unknown, regarding the investigated phenomenon (communication nurse/patient), using one component by which we separated 6 items of the questionnaire. Inter-item correlation (alpha) in this component was 0.96. Pearson correlation coefficient was highly significant, value 0.7 by item, and correlation coefficient for scores at repeated measurements was 0.84. NQCPQ is 6-item instrument with high construct validity. It can be used to measure quality of nurse/patient communication in a simple, fast and reliable way. It could contribute to more adequate research and defining of this problem, and as such could be used in studies of interaction of psychometric, clinical, biochemical, socio-cultural, demographic and other parameters as well.

  6. Evaluation of prospective motion correction of high-resolution 3D-T2-FLAIR acquisitions in epilepsy patients.

    PubMed

    Vos, Sjoerd B; Micallef, Caroline; Barkhof, Frederik; Hill, Andrea; Winston, Gavin P; Ourselin, Sebastien; Duncan, John S

    2018-03-02

    T2-FLAIR is the single most sensitive MRI contrast to detect lesions underlying focal epilepsies but 3D sequences used to obtain isotropic high-resolution images are susceptible to motion artefacts. Prospective motion correction (PMC) - demonstrated to improve 3D-T1 image quality in a pediatric population - was applied to high-resolution 3D-T2-FLAIR scans in adult epilepsy patients to evaluate its clinical benefit. Coronal 3D-T2-FLAIR scans were acquired with a 1mm isotropic resolution on a 3T MRI scanner. Two expert neuroradiologists reviewed 40 scans without PMC and 40 with navigator-based PMC. Visual assessment addressed six criteria of image quality (resolution, SNR, WM-GM contrast, intensity homogeneity, lesion conspicuity, diagnostic confidence) on a seven-point Likert scale (from non-diagnostic to outstanding). SNR was also objectively quantified within the white matter. PMC scans had near-identical scores on the criteria of image quality to non-PMC scans, with the notable exception that intensity homogeneity was generally worse. Using PMC, the percentage of scans with bad image quality was substantially lower than without PMC (3.25% vs. 12.5%) on the other five criteria. Quantitative SNR estimates revealed that PMC and non-PMC had no significant difference in SNR (P=0.07). Application of prospective motion correction to 3D-T2-FLAIR sequences decreased the percentage of low-quality scans, reducing the number of scans that need to be repeated to obtain clinically useful data. Copyright © 2018 The Authors. Published by Elsevier Masson SAS.. All rights reserved.

  7. Laboratory audit as part of the quality assessment of a primary HPV-screening program.

    PubMed

    Hortlund, Maria; Sundström, Karin; Lamin, Helena; Hjerpe, Anders; Dillner, Joakim

    2016-02-01

    As primary HPV screening programs are rolled out, methods are needed for routine quality assurance of HPV laboratory analyzes. To explore the use of similar design for audit as currently used in cytology-based screening, to estimate the clinical sensitivity to identify women at risk for CIN 3 or worse (CIN3+). Population-based cohort study conducted within the cervical screening program in Stockholm, Sweden, in 2011-2012. All women with histopathologically confirmed CIN3+ in the following two years were identified by registry analysis. Primary HPV and cytology screening results were collected. For women who had not been HPV tested, biobanked cytology samples were HPV-tested. If the original HPV result had been negative, the sample and subsequent biopsies were analyzed with broad HPV typing (general primer PCR and Luminex). 154 women had a biobanked prediagnostic cytology sample taken up to 2 years before a histopathologically confirmed CIN3+. The high-risk HPV-positivity was 97% (148/154 women), whereas 143/154 (94%) women had had a cytological abnormality. Among the six HPV-negative samples, one sample was HPV 33 positive in repeat testing whereas the other five cases were HPV-negative also on repeat testing, but HPV-positive in the subsequent tumor tissue. A sensitivity of the HPV test that is higher than the sensitivity of cytology suggests adequate quality of the testing. Regular audits of clinical sensitivity, similar to those of cytology-based screening, should be used also in HPV-based screening programs, in order to continuously monitor the performance of the analyzes. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Sleep and daytime sleepiness of patients with left ventricular assist devices: a longitudinal pilot study.

    PubMed

    Casida, Jesus M; Davis, Jean E; Brewer, Robert J; Smith, Cheryl; Yarandi, Hossein

    2011-06-01

    No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist. (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation. A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients-Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance. We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05). Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.

  9. Bottom-up low molecular weight heparin analysis using liquid chromatography-Fourier transform mass spectrometry for extensive characterization.

    PubMed

    Li, Guoyun; Steppich, Julia; Wang, Zhenyu; Sun, Yi; Xue, Changhu; Linhardt, Robert J; Li, Lingyun

    2014-07-01

    Low molecular weight heparins (LMWHs) are heterogeneous, polydisperse, and highly negatively charged mixtures of glycosaminoglycan chains prescribed as anticoagulants. The detailed characterization of LMWH is important for the drug quality assurance and for new drug research and development. In this study, online hydrophilic interaction chromatography (HILIC) Fourier transform mass spectrometry (FTMS) was applied to analyze the oligosaccharide fragments of LMWHs generated by heparin lyase II digestion. More than 40 oligosaccharide fragments of LMWH were quantified and used to compare LMWHs prepared by three different manufacturers. The quantified fragment structures included unsaturated disaccharides/oligosaccharides arising from the prominent repeating units of these LMWHs, 3-O-sulfo containing tetrasaccharides arising from their antithrombin III binding sites, 1,6-anhydro ring-containing oligosaccharides formed during their manufacture, saturated uronic acid oligosaccharides coming from some chain nonreducing ends, and oxidized linkage region oligosaccharides coming from some chain reducing ends. This bottom-up approach provides rich detailed structural analysis and quantitative information with high accuracy and reproducibility. When combined with the top-down approach, HILIC LC-FTMS based analysis should be suitable for the advanced quality control and quality assurance in LMWH production.

  10. RoCoMAR: robots' controllable mobility aided routing and relay architecture for mobile sensor networks.

    PubMed

    Le, Duc Van; Oh, Hoon; Yoon, Seokhoon

    2013-07-05

    In a practical deployment, mobile sensor network (MSN) suffers from a low performance due to high node mobility, time-varying wireless channel properties, and obstacles between communicating nodes. In order to tackle the problem of low network performance and provide a desired end-to-end data transfer quality, in this paper we propose a novel ad hoc routing and relaying architecture, namely RoCoMAR (Robots' Controllable Mobility Aided Routing) that uses robotic nodes' controllable mobility. RoCoMAR repeatedly performs link reinforcement process with the objective of maximizing the network throughput, in which the link with the lowest quality on the path is identified and replaced with high quality links by placing a robotic node as a relay at an optimal position. The robotic node resigns as a relay if the objective is achieved or no more gain can be obtained with a new relay. Once placed as a relay, the robotic node performs adaptive link maintenance by adjusting its position according to the movements of regular nodes. The simulation results show that RoCoMAR outperforms existing ad hoc routing protocols for MSN in terms of network throughput and end-to-end delay.

  11. RoCoMAR: Robots' Controllable Mobility Aided Routing and Relay Architecture for Mobile Sensor Networks

    PubMed Central

    Van Le, Duc; Oh, Hoon; Yoon, Seokhoon

    2013-01-01

    In a practical deployment, mobile sensor network (MSN) suffers from a low performance due to high node mobility, time-varying wireless channel properties, and obstacles between communicating nodes. In order to tackle the problem of low network performance and provide a desired end-to-end data transfer quality, in this paper we propose a novel ad hoc routing and relaying architecture, namely RoCoMAR (Robots' Controllable Mobility Aided Routing) that uses robotic nodes' controllable mobility. RoCoMAR repeatedly performs link reinforcement process with the objective of maximizing the network throughput, in which the link with the lowest quality on the path is identified and replaced with high quality links by placing a robotic node as a relay at an optimal position. The robotic node resigns as a relay if the objective is achieved or no more gain can be obtained with a new relay. Once placed as a relay, the robotic node performs adaptive link maintenance by adjusting its position according to the movements of regular nodes. The simulation results show that RoCoMAR outperforms existing ad hoc routing protocols for MSN in terms of network throughput and end-to-end delay. PMID:23881134

  12. An acute cough-specific quality-of-life questionnaire for children: Development and validation.

    PubMed

    Anderson-James, Sophie; Newcombe, Peter A; Marchant, Julie M; O'Grady, Kerry-Ann F; Acworth, Jason P; Stone, D Grant; Turner, Catherine T; Chang, Anne B

    2015-05-01

    Patient-relevant outcome measures are essential for high-quality clinical research, and quality-of-life (QoL) tools are the current standard. Currently, there is no validated children's acute cough-specific QoL questionnaire. The objective of this study was to develop and validate the Parent-proxy Children's Acute Cough-specific QoL Questionnaire (PAC-QoL). Using focus groups, a 48-item PAC-QoL questionnaire was developed and later reduced to 16 items by using the clinical impact method. Parents of children with a current acute cough (<2 weeks) at enrollment completed 2 validated cough score measures, the preliminary 48-item PAC-QoL, and 3 other questionnaires (the State Trait Anxiety Inventory [STAI], the Short-Form 8-item 24-hour recall Health Survey [SF-8], and the Depression, Anxiety, and Stress 21-item Scale [DASS21]). All measures were repeated on days 3 and 14. The median age of the 155 children enrolled was 2.3 years (interquartile range, 1.3-4.6). Median cough duration at enrollment was 3 days (interquartile range, 2-5). The reduced 16-item scale had high internal consistency (Cronbach α = 0.95). Evidence for repeatability and criterion validity was shown by significant correlations between the domains and total PAC-QoL scores and the SF-8 (r = -0.36 and -0.51), STAI (r = -0.27 and -0.39), and DASS21 (r = -0.32 and -0.41) scales on days 0 and 3, respectively. The final PAC-QoL questionnaire was sensitive to change over time, with changes significantly relating to changes in cough score measures (P < .001). The 16-item PAC-QoL is a reliable and valid outcome measure that assesses QoL related to childhood acute cough at a given time point and reflects changes in acute cough-specific QoL over time. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  13. High risk for obstructive sleep apnea and other sleep disorders among overweight and obese pregnant women.

    PubMed

    Rice, Jayne R; Larrabure-Torrealva, Gloria T; Luque Fernandez, Miguel Angel; Grande, Mirtha; Motta, Vicky; Barrios, Yasmin V; Sanchez, Sixto; Gelaye, Bizu; Williams, Michelle A

    2015-09-02

    Obstructive sleep apnea (OSA), a common and serious disorder in which breathing repeatedly stops during sleep, is associated with excess weight and obesity. Little is known about the co-occurrence of OSA among pregnant women from low and middle-income countries. We examined the extent to which maternal pre-pregnancy overweight or obesity status are associated with high risk for OSA, poor sleep quality, and excessive daytime sleepiness in 1032 pregnant women in Lima, Peru. The Berlin questionnaire was used to identify women at high risk for OSA. The Pittsburgh Sleep Quality Index (PSQI) and Epworth Sleepiness Scale (ESS) were used to examine sleep quality and excessive daytime sleepiness, respectively. Multinomial logistic regression procedures were employed to estimate odds ratios (aOR) and 95% confidence intervals (CI) adjusted for putative confounding factors. Compared with lean women (<25 kg/m(2)), overweight women (25-29.9 kg/m(2)) had 3.69-fold higher odds of high risk for OSA (95% CI 1.82-7.50). The corresponding aOR for obese women (≥30 kg/m(2)) was 13.23 (95% CI: 6.25-28.01). Obese women, as compared with their lean counterparts had a 1.61-fold higher odds of poor sleep quality (95% CI: 1.00-2.63). Overweight or obese pregnant women have increased odds of sleep disorders, particularly OSA. OSA screening and risk management may be indicated among pregnant women in low and middle income countries, particularly those undergoing rapid epidemiologic transitions characterized by increased prevalence of excessive adult weight gain.

  14. OC30 - Fracture reduction with nitrous oxide at the children's emergency department shortens the length of stay and reduces the use of full anaesthesia in the operating department.

    PubMed

    Lang, Sigrid; Wentzel, Anna-Pia; Ekstrom, Malin

    2016-05-09

    Theme: Accreditation and quality improvement. Dislocated fractures are common in the children's emergency department (ER). All forms of fracture reduction are very painful requiring nitrous oxide. The purpose is to shorten the length of stay in the hospital as well as sustain a high quality of care. All nurses received theoretical and practical training in the use of nitrous oxide. Evaluations with the families were made by telephone. A total of 40 enclosed fracture reductions were made at the ER, leading to a reduction of 33 patients in the operating department and the length of stay was shortened - this compared to the same time in 2014. No adverse event was reported and no patient felt any increase in pain during the treatment. All patients would repeat the procedure if necessary. The treatment has reduced the length of stay in the hospital without affecting the other patients in the ER or the quality of care.

  15. Effect of waxy rice flour and cassava starch on freeze-thaw stability of rice starch gels.

    PubMed

    Charoenrein, Sanguansri; Preechathammawong, Nutsuda

    2012-10-01

    Repeatedly frozen and thawed rice starch gel affects quality. This study investigated how incorporating waxy rice flour (WF) and cassava starch (CS) in rice starch gel affects factors used to measure quality. When rice starch gels containing 0-2% WF and CS were subjected to 5 freeze-thaw cycles, both WF and CS reduced the syneresis in first few cycles. However CS was more effective in reducing syneresis than WF. The different composite arrangement of rice starch with WF or CS caused different mechanisms associated with the rice starch gel retardation of retrogradation, reduced the spongy structure and lowered syneresis. Both swollen granules of rice starch and CS caused an increase in the hardness of the unfrozen and freeze-thawed starch gel while highly swollen WF granules caused softer gels. These results suggested that WF and CS were effective in preserving quality in frozen rice starch based products. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Repeatability of Monocular Acuity Testing in Adults with and without Down Syndrome.

    PubMed

    Ravikumar, Ayeswarya; Benoit, Julia S; Morrison, Kelsie B; Marsack, Jason D; Anderson, Heather A

    2018-03-01

    Individuals with Down syndrome may experience greater difficulty reliably performing visual acuity (VA) tests because of intellectual disability and limitations in visual quality. This study evaluated the repeatability of acuity (Bailey-Lovie [BL] and HOTV) in subjects with and without Down syndrome. High-contrast VA was measured in both eyes of 30 subjects with Down syndrome (mean, 30 years; range, 18 to 50 years) and 24 control subjects without Down syndrome (mean, 29 years; range, 18 to 50 years). In the Down syndrome group, 23 subjects performed BL, and 7 subjects performed HOTV. All control subjects performed both BL and HOTV, but for HOTV analysis, only seven age-matched control subjects were included. For each eye, subjects performed VA three times on different charts (computer controlled, single-line display) until five total letters were missed on each chart. A repeated-measure ANOVA was used to compare the acuity measures between groups. The average logMAR VA for subjects with Down syndrome was approximately six lines worse than the control subjects (BL: Down syndrome = right eye: 0.51 ± 0.16, left eye: 0.53 ± 0.18; control = right eye: -0.06 ± 0.06, left eye: -0.06 ± 0.08, P < .0001; HOTV: Down syndrome = right eye: 0.47 ± 0.19, left eye: 0.46 ± 0.16; control: right eye = -0.11 ± 0.09, left eye: -0.07 ± 0.07, P < .001). Bailey-Lovie VA repeatability (1.96 * Sw * √2) was 0.13 logMAR (6.5 letters) for Down syndrome and 0.09 logMAR (4.5 letters) for control subjects. HOTV VA repeatability was 0.16 logMAR (eight letters) for both Down syndrome and control subjects. Despite poorer acuity in individuals with Down syndrome, repeatability of VA measurements was comparable to control subjects for both BL and HOTV techniques.

  17. Healthcare Transformation and Changing Roles for Nursing

    PubMed Central

    Salmond, Susan W.; Echevarria, Mercedes

    2017-01-01

    Factors driving healthcare transformation include fragmentation, access problems, unsustainable costs, suboptimal outcomes, and disparities. Cost and quality concerns along with changing social and disease-type demographics created the greatest urgency for the need for change. Caring for and paying for medical treatments for patients suffering from chronic health conditions are a significant concern. The Affordable Care Act includes programs now led by the Centers for Medicare & Medicaid Services aiming to improve quality and control cost. Greater coordination of care—across providers and across settings—will improve quality care, improve outcomes, and reduce spending, especially attributed to unnecessary hospitalization, unnecessary emergency department utilization, repeated diagnostic testing, repeated medical histories, multiple prescriptions, and adverse drug interactions. As a nation, we have taken incremental steps toward achieving better quality and lower costs for decades. Nurses are positioned to contribute to and lead the transformative changes that are occurring in healthcare by being a fully contributing member of the interprofessional team as we shift from episodic, provider-based, fee-for-service care to team-based, patient-centered care across the continuum that provides seamless, affordable, and quality care. These shifts require a new or an enhanced set of knowledge, skills, and attitudes around wellness and population care with a renewed focus on patient-centered care, care coordination, data analytics, and quality improvement. PMID:28107295

  18. Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program

    NASA Astrophysics Data System (ADS)

    Paulter, Nicholas G.

    1998-12-01

    The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.

  19. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    PubMed

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  20. Highly sensitive MicroRNA 146a detection using a gold nanoparticle-based CTG repeat probing system and isothermal amplification.

    PubMed

    Le, Binh Huy; Seo, Young Jun

    2018-01-25

    We have developed a gold nanoparticle (AuNP)-based CTG repeat probing system displaying high quenching capability and combined it with isothermal amplification for the detection of miRNA 146a. This method of using a AuNP-based CTG repeat probing system with isothermal amplification allowed the highly sensitive (14 aM) and selective detection of miRNA 146a. A AuNP-based CTG repeat probing system having a hairpin structure and a dT F fluorophore exhibited highly efficient quenching because the CTG repeat-based stable hairpin structure imposed a close distance between the AuNP and the dT F residue. A small amount of miRNA 146a induced multiple copies of the CAG repeat sequence during rolling circle amplification; the AuNP-based CTG repeat probing system then bound to the complementary multiple-copy CAG repeat sequence, thereby inducing a structural change from a hairpin to a linear structure with amplified fluorescence. This AuNP-based CTG probing system combined with isothermal amplification could also discriminate target miRNA 146a from one- and two-base-mismatched miRNAs (ORN 1 and ORN 2, respectively). This simple AuNP-based CTG probing system, combined with isothermal amplification to induce a highly sensitive change in fluorescence, allows the detection of miRNA 146a with high sensitivity (14 aM) and selectivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Holographic Optical Elements Recorded in Silver Halide Sensitized Gelatin Emulsions. Part 2. Reflection Holographic Optical Elements

    NASA Astrophysics Data System (ADS)

    Kim, Jong Man; Choi, Byung So; Choi, Yoon Sun; Kim, Jong Min; Bjelkhagen, Hans I.; Phillips, Nicholas J.

    2002-03-01

    Silver halide sensitized gelatin (SHSG) holograms are similar to holograms recorded in dichromated gelatin (DCG), the main recording material for holographic optical elements (HOEs). The drawback of DCG is its low energetic sensitivity and limited spectral response. Silver halide materials can be processed in such a way that the final hologram will have properties like a DCG hologram. Recently this technique has become more interesting since the introduction of new ultra-fine-grain silver halide (AgHal) emulsions. In particular, high spatial-frequency fringes associated with HOEs of the reflection type are difficult to construct when SHSG processing methods are employed. Therefore an optimized processing technique for reflection HOEs recorded in the new AgHal materials is introduced. Diffraction efficiencies over 90% can be obtained repeatably for reflection diffraction gratings. Understanding the importance of a selective hardening process has made it possible to obtain results similar to conventional DCG processing. The main advantage of the SHSG process is that high-sensitivity recording can be performed with laser wavelengths anywhere within the visible spectrum. This simplifies the manufacturing of high-quality, large-format HOEs, also including high-quality display holograms of the reflection type in both monochrome and full color.

  2. A Treatment Stage Specific Approach to Improving Quality of Life for Women with Ovarian Cancer

    DTIC Science & Technology

    2005-10-01

    This study focuses on quality of life among women with ovarian cancer. The primary objective of the study is to identify the issues that are of...repeated measures design will be used to assess changes in problem areas and quality of life from diagnosis to recurrence among women newly diagnosed with...objectives are of the study are as follows: (1) to assess changes in quality of life (as quantified by the FACT-O questionnaire) across the different

  3. First clinicial results on the feasibility, quality and reproducibility of aberrometry-based intraoperative refraction during cataract surgery.

    PubMed

    Huelle, Jan O; Katz, Toam; Druchkiv, Vasyl; Pahlitzsch, Milena; Steinberg, Johannes; Richard, Gisbert; Linke, Stephan J

    2014-11-01

    To provide the first clinical data in determining the feasibility, quality and precision of intraoperative wavefront aberrometry (IWA)-based refraction in patients with cataract. IWA refraction was recorded at 7 defined measurement points during standardised cataract surgery in 74 eyes of 74 consecutive patients (mean age 69±11.3 years). Precision and measurement quality was evaluated by the 'limits of agreement' approach, regression analysis, correlation analysis, Analysis of variance (ANOVA) and ORs for predicting measurement failure. Wavefront map (WFM) quality was objectivised and compared with the Pentacam Nuclear Staging analysis. Out of 814 IWA measurement attempts, 462 WFMs could be obtained. The most successful readings (n=63) were achieved in aphakia with viscoelastic. The highest (50.63%, SD 20.23) and lowest (29.19%, SD 13.94) quality of WFMs across all measurement points were found after clear corneal incision and in pseudophakia with viscoelastic, respectively. High consistency across repeated measures were found for mean spherical equivalent (SE) differences in aphakia with -0.01D and pseudophakia with -0.01D, but ranges were high (limits of agreement +0.69 D and -0.72 D; +1.53 D and -1.54 D, respectively). With increasing WFM quality, higher precision in measurements was observed. This is the first report addressing quality and reproducibility of WA in a large sample. IWA refraction in aphakia, for instance, appears to be reliable once stable and pressurised anterior chamber conditions are achieved. More efforts are required to improve the precision and quality of measurements before IWA can be used to guide the surgical refractive plan in cataract surgery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Two low coverage bird genomes and a comparison of reference-guided versus de novo genome assemblies.

    PubMed

    Card, Daren C; Schield, Drew R; Reyes-Velasco, Jacobo; Fujita, Matthew K; Andrew, Audra L; Oyler-McCance, Sara J; Fike, Jennifer A; Tomback, Diana F; Ruggiero, Robert P; Castoe, Todd A

    2014-01-01

    As a greater number and diversity of high-quality vertebrate reference genomes become available, it is increasingly feasible to use these references to guide new draft assemblies for related species. Reference-guided assembly approaches may substantially increase the contiguity and completeness of a new genome using only low levels of genome coverage that might otherwise be insufficient for de novo genome assembly. We used low-coverage (∼3.5-5.5x) Illumina paired-end sequencing to assemble draft genomes of two bird species (the Gunnison Sage-Grouse, Centrocercus minimus, and the Clark's Nutcracker, Nucifraga columbiana). We used these data to estimate de novo genome assemblies and reference-guided assemblies, and compared the information content and completeness of these assemblies by comparing CEGMA gene set representation, repeat element content, simple sequence repeat content, and GC isochore structure among assemblies. Our results demonstrate that even lower-coverage genome sequencing projects are capable of producing informative and useful genomic resources, particularly through the use of reference-guided assemblies.

  5. REPDOSE: A database on repeated dose toxicity studies of commercial chemicals--A multifunctional tool.

    PubMed

    Bitsch, A; Jacobi, S; Melber, C; Wahnschaffe, U; Simetska, N; Mangelsdorf, I

    2006-12-01

    A database for repeated dose toxicity data has been developed. Studies were selected by data quality. Review documents or risk assessments were used to get a pre-screened selection of available valid data. The structure of the chemicals should be rather simple for well defined chemical categories. The database consists of three core data sets for each chemical: (1) structural features and physico-chemical data, (2) data on study design, (3) study results. To allow consistent queries, a high degree of standardization categories and glossaries were developed for relevant parameters. At present, the database consists of 364 chemicals investigated in 1018 studies which resulted in a total of 6002 specific effects. Standard queries have been developed, which allow analyzing the influence of structural features or PC data on LOELs, target organs and effects. Furthermore, it can be used as an expert system. First queries have shown that the database is a very valuable tool.

  6. Two low coverage bird genomes and a comparison of reference-guided versus de novo genome assemblies

    USGS Publications Warehouse

    Card, Daren C.; Schield, Drew R.; Reyes-Velasco, Jacobo; Fujita, Matthre K.; Andrew, Audra L.; Oyler-McCance, Sara J.; Fike, Jennifer A.; Tomback, Diana F.; Ruggiero, Robert P.; Castoe, Todd A.

    2014-01-01

    As a greater number and diversity of high-quality vertebrate reference genomes become available, it is increasingly feasible to use these references to guide new draft assemblies for related species. Reference-guided assembly approaches may substantially increase the contiguity and completeness of a new genome using only low levels of genome coverage that might otherwise be insufficient for de novo genome assembly. We used low-coverage (~3.5–5.5x) Illumina paired-end sequencing to assemble draft genomes of two bird species (the Gunnison Sage-Grouse, Centrocercus minimus, and the Clark's Nutcracker, Nucifraga columbiana). We used these data to estimate de novo genome assemblies and reference-guided assemblies, and compared the information content and completeness of these assemblies by comparing CEGMA gene set representation, repeat element content, simple sequence repeat content, and GC isochore structure among assemblies. Our results demonstrate that even lower-coverage genome sequencing projects are capable of producing informative and useful genomic resources, particularly through the use of reference-guided assemblies.

  7. Parenthood and the Quality of Experience in Daily Life: A Longitudinal Study

    ERIC Educational Resources Information Center

    Fave, Antonella Delle; Massimini, Fausto

    2004-01-01

    This longitudinal study analyzes the time budget and the quality of experience reported by new parents. Five primiparous couples were repeatedly administered Experience Sampling Method. They carried pagers sending random signals 6-8 times a day; at the signal reception, they filled out forms sampling current thoughts, activities, and the quality…

  8. Quality of Life of Adults with Pervasive Developmental Disorders and Intellectual Disabilities

    ERIC Educational Resources Information Center

    Gerber, F.; Baud, M. A.; Giroud, M.; Carminati, G. Galli

    2008-01-01

    The purpose of this study was to observe quality of life (QoL) and global evolution of persons with Pervasive Developmental Disorders (PDD) in three different groups. Individualized programs for PDD were compared to traditional programs for intellectual disabilities. Behavioural disorders were repeatedly evaluated using the Aberrant Behaviour…

  9. Talk Alone Won't Close the 30-Million Word Gap

    ERIC Educational Resources Information Center

    Wasik, Barbara A.; Hindman, Annemarie H.

    2015-01-01

    Interventions that affect children's vocabulary development focus on the quality of language as well as quantity. Children need opportunities to talk, use vocabulary words, and respond to adults' questions. Adults need to create opportunities to talk, provide quality feedback on children's language, and use a lot of new vocabulary repeatedly in…

  10. The Relationship between Quality of Discourse during Teacher Induction Classes and Beginning Teachers' Beliefs

    ERIC Educational Resources Information Center

    Decker, Anna-Theresia; Kunter, Mareike; Voss, Thamar

    2015-01-01

    This study investigates whether the quality of discourse during teacher induction classes predicts beginning teachers' reflection and beliefs about teaching and learning mathematics. In a study with repeated measurements (interval 10 months), transmissive and constructivist beliefs of 536 German teacher candidates in their 2-year induction phase…

  11. The Short- and Long-Term Effects of Quality Physical Education

    ERIC Educational Resources Information Center

    Siegel, Donald

    2005-01-01

    The short- and long-term effects of quality physical education programs have been a subject of considerable debate by educational administrators and state legislators during the past decade. While physical educators have repeatedly demonstrated the importance of daily moderate and vigorous physical activity on the immediate health and wellbeing of…

  12. Evaluation of statistical protocols for quality control of ecosystem carbon dioxide fluxes

    Treesearch

    Jorge F. Perez-Quezada; Nicanor Z. Saliendra; William E. Emmerich; Emilio A. Laca

    2007-01-01

    The process of quality control of micrometeorological and carbon dioxide (CO2) flux data can be subjective and may lack repeatability, which would undermine the results of many studies. Multivariate statistical methods and time series analysis were used together and independently to detect and replace outliers in CO2 flux...

  13. Simultaneous glacier surface elevation and flow velocity mapping from cross-track pushbroom satellite Imagery

    NASA Astrophysics Data System (ADS)

    Noh, M. J.; Howat, I. M.

    2017-12-01

    Glaciers and ice sheets are changing rapidly. Digital Elevation Models (DEMs) and Velocity Maps (VMs) obtained from repeat satellite imagery provide critical measurements of changes in glacier dynamics and mass balance over large, remote areas. DEMs created from stereopairs obtained during the same satellite pass through sensor re-pointing (i.e. "in-track stereo") have been most commonly used. In-track stereo has the advantage of minimizing the time separation and, thus, surface motion between image acquisitions, so that the ice surface can be assumed motionless in when collocating pixels between image pairs. Since the DEM extraction process assumes that all motion between collocated pixels is due to parallax or sensor model error, significant ice motion results in DEM quality loss or failure. In-track stereo, however, puts a greater demand on satellite tasking resources and, therefore, is much less abundant than single-scan imagery. Thus, if ice surface motion can be mitigated, the ability to extract surface elevation measurements from pairs of repeat single-scan "cross-track" imagery would greatly increase the extent and temporal resolution of ice surface change. Additionally, the ice motion measured by the DEM extraction process would itself provide a useful velocity measurement. We develop a novel algorithm for generating high-quality DEMs and VMs from cross-track image pairs without any prior information using the Surface Extraction from TIN-based Searchspace Minimization (SETSM) algorithm and its sensor model bias correction capabilities. Using a test suite of repeat, single-scan imagery from WorldView and QuickBird sensors collected over fast-moving outlet glaciers, we develop a method by which RPC biases between images are first calculated and removed over ice-free surfaces. Subpixel displacements over the ice are then constrained and used to correct the parallax estimate. Initial tests yield DEM results with the same quality as in-track stereo for cases where snowfall has not occurred between the two images and when the images have similar ground sample distances. The resulting velocity map also closely matches independent measurements.

  14. Repeated high-intensity exercise in professional rugby union.

    PubMed

    Austin, Damien; Gabbett, Tim; Jenkins, David

    2011-07-01

    The aim of the present study was to describe the frequency, duration, and nature of repeated high-intensity exercise in Super 14 rugby union. Time-motion analysis was used during seven competition matches over the 2008 and 2009 Super 14 seasons; five players from each of four positional groups (front row forwards, back row forwards, inside backs, and outside backs) were assessed (20 players in total). A repeated high-intensity exercise bout was considered to involve three or more sprints, and/or tackles and/or scrum/ruck/maul activities within 21 s during the same passage of play. The range of repeated high-intensity exercise bouts for each group in a match was as follows: 11-18 for front row forwards, 11-21 for back row forwards, 13-18 for inside backs, and 2-11 for outside backs. The durations of the most intense repeated high-intensity exercise bouts for each position ranged from 53 s to 165 s and the minimum recovery periods between repeated high-intensity exercise bouts ranged from 25 s for the back row forwards to 64 s for the front row forwards. The present results show that repeated high-intensity exercise bouts vary in duration and activities relative to position but all players in a game will average at least 10 changes in activity in the most demanding bouts and complete at least one tackle and two sprints. The most intense periods of activity are likely to last as long as 120 s and as little as 25 s recovery may separate consecutive repeated high-intensity exercise bouts. The present findings can be used by coaches to prepare their players for the most demanding passages of play likely to be experienced in elite rugby union.

  15. Molecular layer deposition of APTES on silicon nanowire biosensors: Surface characterization, stability and pH response

    NASA Astrophysics Data System (ADS)

    Liang, Yuchen; Huang, Jie; Zang, Pengyuan; Kim, Jiyoung; Hu, Walter

    2014-12-01

    We report the use of molecular layer deposition (MLD) for depositing 3-aminopropyltriethoxysilane (APTES) on a silicon dioxide surface. The APTES monolayer was characterized using spectroscopic ellipsometry, contact angle goniometry, and atomic force microscopy. Effects of reaction time of repeating pulses and simultaneous feeding of water vapor with APTES were tested. The results indicate that the synergistic effects of water vapor and reaction time are significant for the formation of a stable monolayer. Additionally, increasing the number of repeating pulses improved the APTES surface coverage but led to saturation after 10 pulses. In comparing MLD with solution-phase deposition, the APTES surface coverage and the surface quality were nearly equivalent. The hydrolytic stability of the resulting films was also studied. The results confirmed that the hydrolysis process was necessary for MLD to obtain stable surface chemistry. Furthermore, we compared the pH sensing results of Si nanowire field effect transistors (Si NWFETs) modified by both the MLD and solution methods. The highly repeatable pH sensing results reflected the stability of APTES monolayers. The results also showed an improved pH response of the sensor prepared by MLD compared to the one prepared by the solution treatment, which indicated higher surface coverage of APTES.

  16. Inter-observer agreement on a checklist to evaluate scientific publications in the field of animal reproduction.

    PubMed

    Simoneit, Céline; Heuwieser, Wolfgang; Arlt, Sebastian P

    2012-01-01

    This study's objective was to determine respondents' inter-observer agreement on a detailed checklist to evaluate three exemplars (one case report, one randomized controlled study without blinding, and one blinded, randomized controlled study) of the scientific literature in the field of bovine reproduction. Fourteen international scientists in the field of animal reproduction were provided with the three articles, three copies of the checklist, and a supplementary explanation. Overall, 13 responded to more than 90% of the items. Overall repeatability between respondents using Fleiss's κ was 0.35 (fair agreement). Combining the "strongly agree" and "agree" responses and the "strongly disagree" and "disagree" responses increased κ to 0.49 (moderate agreement). Evaluation of information given in the three articles on housing of the animals (35% identical answers) and preconditions or pretreatments (42%) varied widely. Even though the overall repeatability was fair, repeatability concerning the important categories was high (e.g., level of agreement=98%). Our data show that the checklist is a reasonable and practical supporting tool to assess the quality of publications. Therefore, it may be used in teaching and practicing evidence-based veterinary medicine. It can support training in systematic and critical appraisal of information and in clinical decision making.

  17. Radiation dose-reduction strategies in thoracic CT.

    PubMed

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Automatic welding of stainless steel tubing

    NASA Technical Reports Server (NTRS)

    Clautice, W. E.

    1978-01-01

    The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.

  19. Regularity of daily life in relation to personality, age, gender, sleep quality and circadian rhythms

    NASA Technical Reports Server (NTRS)

    Monk, T. H.; Petrie, S. R.; Hayes, A. J.; Kupfer, D. J.

    1994-01-01

    A diary-like instrument to measure lifestyle regularity (the 'Social Rhythm Metric'-SRM) was given to 96 subjects (48 women, 48 men), 39 of whom repeated the study after at least one year, with additional objective measures of rest/activity. Lifestyle regularity as measured by the SRM related to age, morningness, subjective sleep quality and time-of-day variations in alertness, but not to gender, extroversion or neuroticism. Statistically significant test-retest correlations of about 0.4 emerged for SRM scores over the 12-30 month delay. Diary-based estimates of bedtime and waketime appeared fairly reliable. In a further study of healthy young men, 4 high SRM scorers ('regular') had a deeper nocturnal body temperature trough than 5 low SRM scorers ('irregular'), suggesting a better functioning circadian system in the 'regular' group.

  20. Iterative metal artifact reduction: evaluation and optimization of technique.

    PubMed

    Subhas, Naveen; Primak, Andrew N; Obuchowski, Nancy A; Gupta, Amit; Polster, Joshua M; Krauss, Andreas; Iannotti, Joseph P

    2014-12-01

    Iterative metal artifact reduction (IMAR) is a sinogram inpainting technique that incorporates high-frequency data from standard weighted filtered back projection (WFBP) reconstructions to reduce metal artifact on computed tomography (CT). This study was designed to compare the image quality of IMAR and WFBP in total shoulder arthroplasties (TSA); determine the optimal amount of WFBP high-frequency data needed for IMAR; and compare image quality of the standard 3D technique with that of a faster 2D technique. Eight patients with nine TSA underwent CT with standardized parameters: 140 kVp, 300 mAs, 0.6 mm collimation and slice thickness, and B30 kernel. WFBP, three 3D IMAR algorithms with different amounts of WFBP high-frequency data (IMARlo, lowest; IMARmod, moderate; IMARhi, highest), and one 2D IMAR algorithm were reconstructed. Differences in attenuation near hardware and away from hardware were measured and compared using repeated measures ANOVA. Five readers independently graded image quality; scores were compared using Friedman's test. Attenuation differences were smaller with all 3D IMAR techniques than with WFBP (p < 0.0063). With increasing high-frequency data, the attenuation difference increased slightly (differences not statistically significant). All readers ranked IMARmod and IMARhi more favorably than WFBP (p < 0.05), with IMARmod ranked highest for most structures. The attenuation difference was slightly higher with 2D than with 3D IMAR, with no significant reader preference for 3D over 2D. IMAR significantly decreases metal artifact compared to WFBP both objectively and subjectively in TSA. The incorporation of a moderate amount of WFBP high-frequency data and use of a 2D reconstruction technique optimize image quality and allow for relatively short reconstruction times.

  1. Printing versus coating - What will be the future production technology for printed electronics?

    NASA Astrophysics Data System (ADS)

    Glawe, Andrea; Eggerath, Daniel; Schäfer, Frank

    2015-02-01

    The market of Large Area Organic Printed Electronics is developing rapidly to increase efficiency and quality as well as to lower costs further. Applications for OPV, OLED, RFID and compact Printed Electronic systems are increasing. In order to make the final products more affordable, but at the same time highly accurate, Roll to Roll (R2R) production on flexible transparent polymer substrates is the way forward. There are numerous printing and coating technologies suitable depending on the design, the product application and the chemical process technology. Mainly the product design (size, pattern, repeatability) defines the application technology.

  2. Advances with holographic DESA emulsions

    NASA Astrophysics Data System (ADS)

    Dünkel, Lothar; Eichler, Jürgen; Schneeweiss, Claudia; Ackermann, Gerhard

    2006-02-01

    DESA emulsions represent layer systems based on ultra-fine grained silver halide (AgX) technology. The new layers have an excellent performance for holographic application. The technology has been presented repeatedly in recent years, including the emulsion characterization and topics of chemical and spectral sensitization. The paper gives a survey of actual results referring to panchromatic sensitization and other improvements like the application of silver halide sensitized gelatine (SHSG) procedure. These results are embedded into intensive collaborations with small and medium enterprises (SME's) to commercialize DESA layers. Predominant goals are innovative products with holographic components and layers providing as well as cost effectiveness and high quality.

  3. Valid internal standard technique for arson detection based on gas chromatography-mass spectrometry.

    PubMed

    Salgueiro, Pedro A S; Borges, Carlos M F; Bettencourt da Silva, Ricardo J N

    2012-09-28

    The most popular procedures for the detection of residues of accelerants in fire debris are the ones published by the American Society for Testing and Materials (ASTM E1412-07 and E1618-10). The most critical stages of these tests are the conservation of fire debris from the sampling to the laboratory, the extraction of residues of accelerants from the debris to the activated charcoal strips (ACS) and from those to the final solvent, as well as the analysis of sample extract by gas chromatography-mass spectrometry (GC-MS) and the interpretation of the instrumental signal. This work proposes a strategy for checking the quality of the sample conservation, the accelerant residues transference to final solvent and GC-MS analysis, using internal standard additions. It is used internal standards ranging from a highly volatile compound for checking debris conservation to low volatile compound for checking GC-MS repeatability. The developed quality control (QC) parameters are not affected by GC-MS sensitivity variation and, specifically, the GC-MS performance control is not affected by ACS adsorption saturation that may mask test performance deviations. The proposed QC procedure proved to be adequate to check GC-MS repeatability, ACS extraction and sample conservation since: (1) standard additions are affected by negligible uncertainty and (2) observed dispersion of QC parameters are fit for its intended use. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Development of a gene-centered ssr atlas as a resource for papaya (Carica papaya) marker-assisted selection and population genetic studies.

    PubMed

    Vidal, Newton Medeiros; Grazziotin, Ana Laura; Ramos, Helaine Christine Cancela; Pereira, Messias Gonzaga; Venancio, Thiago Motta

    2014-01-01

    Carica papaya (papaya) is an economically important tropical fruit. Molecular marker-assisted selection is an inexpensive and reliable tool that has been widely used to improve fruit quality traits and resistance against diseases. In the present study we report the development and validation of an atlas of papaya simple sequence repeat (SSR) markers. We integrated gene predictions and functional annotations to provide a gene-centered perspective for marker-assisted selection studies. Our atlas comprises 160,318 SSRs, from which 21,231 were located in genic regions (i.e. inside exons, exon-intron junctions or introns). A total of 116,453 (72.6%) of all identified repeats were successfully mapped to one of the nine papaya linkage groups. Primer pairs were designed for markers from 9,594 genes (34.5% of the papaya gene complement). Using papaya-tomato orthology assessments, we assembled a list of 300 genes (comprising 785 SSRs) potentially involved in fruit ripening. We validated our atlas by screening 73 SSR markers (including 25 fruit ripening genes), achieving 100% amplification rate and uncovering 26% polymorphism rate between the parental genotypes (Sekati and JS12). The SSR atlas presented here is the first comprehensive gene-centered collection of annotated and genome positioned papaya SSRs. These features combined with thousands of high-quality primer pairs make the atlas an important resource for the papaya research community.

  5. Deep landscape update of dispersed and tandem repeats in the genome model of the red jungle fowl, Gallus gallus, using a series of de novo investigating tools.

    PubMed

    Guizard, Sébastien; Piégu, Benoît; Arensburger, Peter; Guillou, Florian; Bigot, Yves

    2016-08-19

    The program RepeatMasker and the database Repbase-ISB are part of the most widely used strategy for annotating repeats in animal genomes. They have been used to show that avian genomes have a lower repeat content (8-12 %) than the sequenced genomes of many vertebrate species (30-55 %). However, the efficiency of such a library-based strategies is dependent on the quality and completeness of the sequences in the database that is used. An alternative to these library based methods are methods that identify repeats de novo. These alternative methods have existed for a least a decade and may be more powerful than the library based methods. We have used an annotation strategy involving several complementary de novo tools to determine the repeat content of the model genome galGal4 (1.04 Gbp), including identifying simple sequence repeats (SSRs), tandem repeats and transposable elements (TEs). We annotated over one Gbp. of the galGal4 genome and showed that it is composed of approximately 19 % SSRs and TEs repeats. Furthermore, we estimate that the actual genome of the red jungle fowl contains about 31-35 % repeats. We find that library-based methods tend to overestimate TE diversity. These results have a major impact on the current understanding of repeats distributions throughout chromosomes in the red jungle fowl. Our results are a proof of concept of the reliability of using de novo tools to annotate repeats in large animal genomes. They have also revealed issues that will need to be resolved in order to develop gold-standard methodologies for annotating repeats in eukaryote genomes.

  6. Effect of baby oil on pruritus, sleep quality, and quality of life in hemodialysis patients: pretest-post-test model with control groups.

    PubMed

    Karadag, Ezgi; Kilic, Serap Parlar; Karatay, Gülnaz; Metin, Ozgur

    2014-07-01

    To assess the effect of baby oil on pruritus, sleep quality, and quality of life in hemodialysis (HD) patients. This pretest-post-test model with control groups study was conducted in HD units in two different provinces in eastern Turkey. The study group consisted of a total of 70 patients receiving HD treatment who met the inclusion criteria, 35 being in the intervention group and 35 in the control group. After the patients in both groups were informed about the study, they were administered a questionnaire, the Severity Scale, Visual Analog Scale, the Pittsburgh Sleep Quality Index, and the SF-36 Quality of Life Scale. Following the administration of baby oil to the patients in the intervention group three times a week for a period of 1 month, the same scales were repeated to explore their pruritic status, sleep quality, and quality of life. The same scales were repeated also for the patients in the control group 1 month later but without administering any baby oil. When the Itch Severity Scale, Visual Analog Scale, Pittsburgh Sleep Quality Index, and SF-36 Quality of Life Physical and Mental Component scores of the patients in the control and intervention groups before and after the intervention were compared, the differences in the change were found to be statistically significant in favor of the intervention group (P < 0.05). It was found in this study that administration of baby oil had positive effects on itching, quality of life, and sleep quality in HD patients who had itching complaints. © 2013 The Authors. Japan Journal of Nursing Science © 2013 Japan Academy of Nursing Science.

  7. Composite Quality Measures for Common Inpatient Medical Conditions

    PubMed Central

    Chen, Lena M.; Staiger, Douglas O.; Birkmeyer, John D.; Ryan, Andrew M.; Zhang, Wenying; Dimick, Justin B.

    2014-01-01

    Background Public reporting on quality aims to help patients select better hospitals. However, individual quality measures are sub-optimal in identifying superior and inferior hospitals based on outcome performance. Objective To combine structure, process, and outcome measures into an empirically-derived composite quality measure for heart failure (HF), acute myocardial infarction (AMI), and pneumonia (PNA). To assess how well the composite measure predicts future high and low performers, and explains variance in future hospital mortality. Research Design Using national Medicare data, we created a cohort of older patients treated at an acute care hospital for HF (n=1,203,595), AMI (n=625,595), or PNA (n=1,234,299). We ranked hospitals based on their July 2005 to June 2008 performance on the composite. We then estimated the odds of future (July to December 2009) 30-day, risk-adjusted mortality at the worst vs. best quintile of hospitals. We repeated this analysis using 2005-2008 performance on existing quality indicators, including mortality. Results The composite (vs. Hospital Compare) explained 68% (vs. 39%) of variation in future AMI mortality rates. In 2009, if an AMI patient had chosen a hospital in the worst vs. best quintile of performance using 2005-2008 composite (vs. Hospital Compare) rankings, he or she would have had 1.61 (vs. 1.39) times the odds of dying in 30 days (p-value for difference < 0.001). Results were similar for HF and PNA. Conclusions Composite measures of quality for HF, AMI, and PNA performed better than existing measures at explaining variation in future mortality and predicting future high and low performers. PMID:23942222

  8. Empirical Tryout of a New Statistic for Detecting Temporally Inconsistent Responders.

    PubMed

    Kerry, Matthew J

    2018-01-01

    Statistical screening of self-report data is often advised to support the quality of analyzed responses - For example, reduction of insufficient effort responding (IER). One recently introduced index based on Mahalanobis's D for detecting outliers in cross-sectional designs replaces centered scores with difference scores between repeated-measure items: Termed person temporal consistency ( D 2 ptc ). Although the adapted D 2 ptc index demonstrated usefulness in simulation datasets, it has not been applied to empirical data. The current study addresses D 2 ptc 's low uptake by critically appraising its performance across three empirical applications. Independent samples were selected to represent a range of scenarios commonly encountered by organizational researchers. First, in Sample 1, a repeat-measure of future time perspective (FTP) inexperienced working adults (age >40-years; n = 620) indicated that temporal inconsistency was significantly related to respondent age and item reverse-scoring. Second, in repeat-measure of team efficacy aggregations, D 2 ptc successfully detected team-level inconsistency across repeat-performance cycles. Thirdly, the usefulness of the D 2 ptc was examined in an experimental study dataset of subjective life expectancy indicated significantly more stable responding in experimental conditions compared to controls. The empirical findings support D 2 ptc 's flexible and useful application to distinct study designs. Discussion centers on current limitations and further extensions that may be of value to psychologists screening self-report data for strengthening response quality and meaningfulness of inferences from repeated-measures self-reports. Taken together, the findings support the usefulness of the newly devised statistic for detecting IER and other extreme response patterns.

  9. The virtues of balm in late medieval literature.

    PubMed

    Truitt, Elly R

    2009-01-01

    This article argues that balm, or balsam, was, by the late medieval period, believed to be a panacea, capable of healing wounds and illnesses, and also preventing putrefaction. Natural history and pharmacological texts on balm from the ancient and late antique periods emphasized specific qualities of balm, especially its heat; these were condensed and repeated in medieval encyclopedias. The rarity and cost of balsam, from antiquity through the medieval period, and the high rate of counterfeiting also demonstrate its high demand and significance in medicine and religious ritual. Travel writing and itineraria from the early and central medieval periods added a new layer to ideas about the capabilities of balsam: that it originated from a Christian miracle and was a particularly Christian plant.

  10. A methodological pilot: parenting among women in substance abuse treatment.

    PubMed

    Lewin, Linda; Farkas, Kathleen; Niazi, Maryam

    2014-01-01

    Mothers who abuse substances are likely to have insecure emotional attachment with their children, placing their children at risk for social-emotional and psychiatric conditions. Sobriety does not inevitably improve parenting. We tested recruitment methods, audiovisual (AV) recording procedures, the protocol for identifying child abuse risk, the coding of mother-child interactions, and retention of the sample for repeated measures as the first phase in examining mother-child relational quality of women in substance abuse treatment. This innovative study involved AV recordings to capture the in-vivo mother-child interactional behaviors that were later coded and analyzed for mean scores on the 64-item Parent-Child Relational Quality Assessment. Repeated measurement was planned during treatment and two months after discharge from treatment. The pilot involved a small sample (n = 11) of mother-child (<6 years) dyads. Highest and lowest ratings of interaction behaviors were identified. Mothers showed less enthusiasm and creativity but matched their child's emotional state. The children showed appropriate motor skill items and attachment behaviors. The dyad coding showed less mutual enjoyment between the mother and child. Eight of the participants could not be located for the second measurement despite multiple contact methods. AV recordings capture rich, descriptive information that can be coded for interactional quality analysis. Repeated measurement with this cohort was not feasible, thus needing to assess for additional/more frequent contacts to maintain the sample.

  11. Data fusion in data scarce areas using a back-propagation artificial neural network model: a case study of the South China Sea

    NASA Astrophysics Data System (ADS)

    Wang, Zheng; Mao, Zhihua; Xia, Junshi; Du, Peijun; Shi, Liangliang; Huang, Haiqing; Wang, Tianyu; Gong, Fang; Zhu, Qiankun

    2018-06-01

    The cloud cover for the South China Sea and its coastal area is relatively large throughout the year, which limits the potential application of optical remote sensing. A HJ-charge-coupled device (HJ-CCD) has the advantages of wide field, high temporal resolution, and short repeat cycle. However, this instrument suffers from its use of only four relatively low-quality bands which can't adequately resolve the features of long wavelengths. The Landsat Enhanced Thematic Mapper-plus (ETM+) provides high-quality data, however, the Scan Line Corrector (SLC) stopped working and caused striping of remote sensed images, which dramatically reduced the coverage of the ETM+ data. In order to combine the advantages of the HJ-CCD and Landsat ETM+ data, we adopted a back-propagation artificial neural network (BP-ANN) to fuse these two data types for this study. The results showed that the fused output data not only have the advantage of data intactness for the HJ-CCD, but also have the advantages of the multi-spectral and high radiometric resolution of the ETM+ data. Moreover, the fused data were analyzed qualitatively, quantitatively and from a practical application point of view. Experimental studies indicated that the fused data have a full spatial distribution, multi-spectral bands, high radiometric resolution, a small difference between the observed and fused output data, and a high correlation between the observed and fused data. The excellent performance in its practical application is a further demonstration that the fused data are of high quality.

  12. How seed orchard culture affects seed quality: experience with the southern pines

    Treesearch

    James P. Barnett

    1996-01-01

    Tree improvement programs have influenced significantly the quality of southern pine seeds produced when compared to collections from native stands. Seed orchard management practices such as fertilization can increase seed size and reduce seed dormancy. These result in the need for less complex pregermination treatments. Repeated cone collections from the same clones...

  13. The Design and Validation of a Parent-Report Questionnaire for Assessing the Characteristics and Quality of Early Intervention over Time

    ERIC Educational Resources Information Center

    Young, Alys; Gascon-Ramos, Maria; Campbell, Malcolm; Bamford, John

    2009-01-01

    This article concerns a parent-report repeat questionnaire to evaluate the quality of multiprofessional early intervention following early identification of deafness. It discusses the rationale for the design of the instrument, its theoretical underpinnings, its psychometric properties, and its usability. Results for the validity and reliability…

  14. Reliability of the Melbourne assessment of unilateral upper limb function.

    PubMed

    Randall, M; Carlin, J B; Chondros, P; Reddihough, D

    2001-11-01

    This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.

  15. Impact of an Activity-Based Program on Health, Quality of Life, and Occupational Performance of Women Diagnosed With Cancer.

    PubMed

    Maher, Colleen; Mendonca, Rochelle J

    We evaluated the impact of a 1-wk activity program on the health, quality of life (QOL), and occupational performance of community-living women diagnosed with cancer. A one-group pretest-posttest repeated-measures design was used. Participants completed a functional health measure (36-Item Short Form Health Survey [SF-36]), a QOL measure (World Health Organization Quality of Life-Brief version [WHOQOL-BREF]), and an occupational performance and satisfaction measure (Canadian Occupational Performance Measure [COPM]) before and 6 wk after program completion. The COPM was also administered on Day 5. Paired t tests for the SF-36 and WHOQOL-BREF showed no significant differences, except for the WHOQOL-BREF's Social Relationships subscale (p < .008). Repeated-measures analyses of variance showed a significant difference in COPM performance and satisfaction scores (p < .001). The activity program effectively improved occupational performance and satisfaction and social relationships of community-living women diagnosed with cancer. Copyright © 2018 by the American Occupational Therapy Association, Inc.

  16. Multibehavioural Interventions with a Focus on Specific Energy Balance-Related Behaviours Can Affect Diet Quality in Preschoolers from Six European Countries: The ToyBox-Study

    PubMed Central

    Pinket, An-Sofie; De Craemer, Marieke; Huybrechts, Inge; De Bourdeaudhuij, Ilse; Deforche, Benedicte; Cardon, Greet; Androutsos, Odysseas; Koletzko, Berthold; Moreno, Luis A.; Socha, Piotr; Iotova, Violeta; Manios, Yannis; Van Lippevelde, Wendy

    2017-01-01

    The present study aimed to examine whether a multibehavioural intervention with a focus on specific energy balance-related behaviours can affect total diet quality and its four subcomponents in European preschoolers and to investigate if these intervention effects differed by socioeconomic status (SES). Parents/caregivers of 3.5 to 5.5 year-olds (n = 4968) recruited through kindergartens in six European countries within the ToyBox-study completed questionnaires on socio-demographics and a food frequency questionnaire on their preschoolers’ diet. To assess intervention effects and differences by SES, multilevel repeated measures analyses were conducted. In contrast to no significant difference in total diet quality, in both the intervention and control group, the dietary quality and dietary equilibrium increased, with a larger increase in the intervention group (mean difference quality: +3.4%; mean difference equilibrium: +0.9%) compared to the control group (quality: +1.5%; equilibrium: +0.2%). SES was not a significant moderator for intervention effects on total diet quality, nor for the four subcomponents. This study indicates that multibehavioural interventions with a focus on specific energy balance-related behaviours in preschoolers not only affect those targeted behaviours, but can also have more generalized effects. The ToyBox-intervention effects were similar for both lower and high SES preschoolers. PMID:28489048

  17. Internal Quality Control Practices in Coagulation Laboratories: recommendations based on a patterns-of-practice survey.

    PubMed

    McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R

    2015-12-01

    Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.

  18. Langley Wind Tunnel Data Quality Assurance-Check Standard Results

    NASA Technical Reports Server (NTRS)

    Hemsch, Michael J.; Grubb, John P.; Krieger, William B.; Cler, Daniel L.

    2000-01-01

    A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.

  19. Evolution of Determinant Factors of Repeated Sprint Ability.

    PubMed

    Pareja-Blanco, Fernando; Suarez-Arrones, Luis; Rodríguez-Rosell, David; López-Segovia, Manuel; Jiménez-Reyes, Pedro; Bachero-Mena, Beatriz; González-Badillo, Juan José

    2016-12-01

    The aim of this study was to investigate the changes in the relationships between repeated sprint ability (RSA) and anthropometric measures as well as fitness qualities in soccer players. Twenty-one professional soccer players performed several anthropometric and physical tests including countermovement vertical jumps (CMJs), a straight-line 30 m sprint (T30), an RSA test (6 x 20 + 20 m with 20 s recovery), a progressive isoinertial loading test in a full squat, a Yo-Yo Intermittent Recovery Test Level-1 (YYIRT-1) and a 20 m shuttle run test (20mSRT). The mean (RSAmean), the fastest (RSAbest), each single sprint time, and the percentage in a sprint decrease (%Dec) in the RSA test were calculated. RSAbest correlated significantly with RSAmean (r = .82) and with all single sprints (p < 0.05), showing a downward trend as the number of sprints performed increased. No significant relationship was observed between the %Dec and RSA performance. CMJs and the T30 also showed a correlation with RSA performance, whereas lower limb strength did not show any relationship with RSA performance. RSAmean showed significant (p < 0.05) relationships with body mass (r = .44), adiposity (r = .59) and the YYIRT-1 (r = -.62), increasing as the number of repeated sprints increased. The 20mSRT showed minimal relationships with RSA performance. In conclusion, maximal sprint capacity seems to be relevant for the RSA performance, mainly in the first sprints. However, high intermittent endurance capacity and low adiposity might help enhance the RSA performance when increasing the number of repeated sprints.

  20. Evolution of Determinant Factors of Repeated Sprint Ability

    PubMed Central

    Suarez-Arrones, Luis; Rodríguez-Rosell, David; López-Segovia, Manuel; Jiménez-Reyes, Pedro; Bachero-Mena, Beatriz; González-Badillo, Juan José

    2016-01-01

    Abstract The aim of this study was to investigate the changes in the relationships between repeated sprint ability (RSA) and anthropometric measures as well as fitness qualities in soccer players. Twenty-one professional soccer players performed several anthropometric and physical tests including countermovement vertical jumps (CMJs), a straight-line 30 m sprint (T30), an RSA test (6 x 20 + 20 m with 20 s recovery), a progressive isoinertial loading test in a full squat, a Yo-Yo Intermittent Recovery Test Level-1 (YYIRT-1) and a 20 m shuttle run test (20mSRT). The mean (RSAmean), the fastest (RSAbest), each single sprint time, and the percentage in a sprint decrease (%Dec) in the RSA test were calculated. RSAbest correlated significantly with RSAmean (r = .82) and with all single sprints (p < 0.05), showing a downward trend as the number of sprints performed increased. No significant relationship was observed between the %Dec and RSA performance. CMJs and the T30 also showed a correlation with RSA performance, whereas lower limb strength did not show any relationship with RSA performance. RSAmean showed significant (p < 0.05) relationships with body mass (r = .44), adiposity (r = .59) and the YYIRT-1 (r = -.62), increasing as the number of repeated sprints increased. The 20mSRT showed minimal relationships with RSA performance. In conclusion, maximal sprint capacity seems to be relevant for the RSA performance, mainly in the first sprints. However, high intermittent endurance capacity and low adiposity might help enhance the RSA performance when increasing the number of repeated sprints. PMID:28031763

  1. Integration of promoters, inverted repeat sequences and proteomic data into a model for high silencing efficiency of coeliac disease related gliadins in bread wheat

    PubMed Central

    2013-01-01

    Background Wheat gluten has unique nutritional and technological characteristics, but is also a major trigger of allergies and intolerances. One of the most severe diseases caused by gluten is coeliac disease. The peptides produced in the digestive tract by the incomplete digestion of gluten proteins trigger the disease. The majority of the epitopes responsible reside in the gliadin fraction of gluten. The location of the multiple gliadin genes in blocks has to date complicated their elimination by classical breeding techniques or by the use of biotechnological tools. As an approach to silence multiple gliadin genes we have produced 38 transgenic lines of bread wheat containing combinations of two endosperm-specific promoters and three different inverted repeat sequences to silence three fractions of gliadins by RNA interference. Results The effects of the RNA interference constructs on the content of the gluten proteins, total protein and starch, thousand seed weights and SDSS quality tests of flour were analyzed in these transgenic lines in two consecutive years. The characteristics of the inverted repeat sequences were the main factor that determined the efficiency of silencing. The promoter used had less influence on silencing, although a synergy in silencing efficiency was observed when the two promoters were used simultaneously. Genotype and the environment also influenced silencing efficiency. Conclusions We conclude that to obtain wheat lines with an optimum reduction of toxic gluten epitopes one needs to take into account the factors of inverted repeat sequences design, promoter choice and also the wheat background used. PMID:24044767

  2. Signal quality improvement using cylindrical confinement for laser induced breakdown spectroscopy.

    PubMed

    Hou, Zongyu; Wang, Zhe; Liu, Jianmin; Ni, Weidou; Li, Zheng

    2013-07-01

    In our previous work, we found that there was great potential to improve the pulse-to-pulse signal repeatability using a moderate cylindrical cavity confinement. However, the improvement was achieved only with certain experimental parameters; while under other conditions, there was no improvement or even worse repeatability. In the present work, the experimental configuration was redesigned and unexpected uncertainty from the variation of the laser and cavity alignment and the laser ablated aerosols were avoided. With these two improvements, we demonstrated that the cavity can always increase the signal repeatability. In addition, image taken by ICCD verified that the confinement improved the stability of the plasma morphology as expected.

  3. Repeat associated mechanisms of genome evolution and function revealed by the Mus caroli and Mus pahari genomes.

    PubMed

    Thybert, David; Roller, Maša; Navarro, Fábio C P; Fiddes, Ian; Streeter, Ian; Feig, Christine; Martin-Galvez, David; Kolmogorov, Mikhail; Janoušek, Václav; Akanni, Wasiu; Aken, Bronwen; Aldridge, Sarah; Chakrapani, Varshith; Chow, William; Clarke, Laura; Cummins, Carla; Doran, Anthony; Dunn, Matthew; Goodstadt, Leo; Howe, Kerstin; Howell, Matthew; Josselin, Ambre-Aurore; Karn, Robert C; Laukaitis, Christina M; Jingtao, Lilue; Martin, Fergal; Muffato, Matthieu; Nachtweide, Stefanie; Quail, Michael A; Sisu, Cristina; Stanke, Mario; Stefflova, Klara; Van Oosterhout, Cock; Veyrunes, Frederic; Ward, Ben; Yang, Fengtang; Yazdanifar, Golbahar; Zadissa, Amonida; Adams, David J; Brazma, Alvis; Gerstein, Mark; Paten, Benedict; Pham, Son; Keane, Thomas M; Odom, Duncan T; Flicek, Paul

    2018-04-01

    Understanding the mechanisms driving lineage-specific evolution in both primates and rodents has been hindered by the lack of sister clades with a similar phylogenetic structure having high-quality genome assemblies. Here, we have created chromosome-level assemblies of the Mus caroli and Mus pahari genomes. Together with the Mus musculus and Rattus norvegicus genomes, this set of rodent genomes is similar in divergence times to the Hominidae (human-chimpanzee-gorilla-orangutan). By comparing the evolutionary dynamics between the Muridae and Hominidae, we identified punctate events of chromosome reshuffling that shaped the ancestral karyotype of Mus musculus and Mus caroli between 3 and 6 million yr ago, but that are absent in the Hominidae. Hominidae show between four- and sevenfold lower rates of nucleotide change and feature turnover in both neutral and functional sequences, suggesting an underlying coherence to the Muridae acceleration. Our system of matched, high-quality genome assemblies revealed how specific classes of repeats can play lineage-specific roles in related species. Recent LINE activity has remodeled protein-coding loci to a greater extent across the Muridae than the Hominidae, with functional consequences at the species level such as reproductive isolation. Furthermore, we charted a Muridae-specific retrotransposon expansion at unprecedented resolution, revealing how a single nucleotide mutation transformed a specific SINE element into an active CTCF binding site carrier specifically in Mus caroli , which resulted in thousands of novel, species-specific CTCF binding sites. Our results show that the comparison of matched phylogenetic sets of genomes will be an increasingly powerful strategy for understanding mammalian biology. © 2018 Thybert et al.; Published by Cold Spring Harbor Laboratory Press.

  4. Aconitum alkaloid content and the high toxicity of aconite tincture.

    PubMed

    Chan, Thomas Y K

    2012-10-10

    Although proprietary medicines and decoction of processed aconite roots are the most widely used, tincture accounts for the great majority of aconite poisoning cases in China, indicating that it is much more toxic than other formulations. Aconite tincture is often self-prepared at home and raw aconite plants or roots are often used. Even if processed aconite roots were used to make the tincture, the amount of Aconitum alkaloids is highly variable, depending on the adequacy of processing and quality control. Aconitum alkaloids dissolve efficiently in alcohol. For these reasons, tincture contains very high concentrations of Aconitum alkaloids. Despite its high intrinsic toxicity, overdose of aconite tincture by the users has been common. Severe aconite poisoning can be complicated by fatal ventricular tachyarrhythmias and asystole. The public should be repeatedly warned of the danger of taking aconite tincture by mouth. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Considerations on repeated repairing of weldments in Inconel 718 alloy

    NASA Technical Reports Server (NTRS)

    Bayless, E. O.; Lovoy, C. V.; Mcilwain, M. C.; Munafo, P.

    1981-01-01

    The effects of repeated weld repairs on the metallurgical characteristics, high cycle fatigue (HCF), and tensile properties of Inconel 718 butt weld joints were determined. A 1/4 in thick plate and a 1/2 in thick plate were used as well as tungsten inert gas welding, and Inconel 718 filler wire. Weld panels were subjected to 2, 6, and 12 repeated repairs and were made in a highly restrained condition. Post weld heat treatments were also conducted with the welded panel in the highly restrained condition. Results indicate that no significant metallurgical anomaly is evident as a result of up to twelve repeated weld repairs. No degradation in fatigue life is noted for up to twelve repeated repairs. Tensile results from specimens which contained up to twelve repeated weld repairs revealed no significant degradation in UTS and YS. However, a significant decrease in elongation is evident with specimens (solution treated and age hardened after welding) which contained twelve repeated repairs. The elongation loss is attributed to the presence of a severe notch on each side (fusion line) of the repair weld bead reinforcement.

  6. Direct mapping of symbolic DNA sequence into frequency domain in global repeat map algorithm

    PubMed Central

    Glunčić, Matko; Paar, Vladimir

    2013-01-01

    The main feature of global repeat map (GRM) algorithm (www.hazu.hr/grm/software/win/grm2012.exe) is its ability to identify a broad variety of repeats of unbounded length that can be arbitrarily distant in sequences as large as human chromosomes. The efficacy is due to the use of complete set of a K-string ensemble which enables a new method of direct mapping of symbolic DNA sequence into frequency domain, with straightforward identification of repeats as peaks in GRM diagram. In this way, we obtain very fast, efficient and highly automatized repeat finding tool. The method is robust to substitutions and insertions/deletions, as well as to various complexities of the sequence pattern. We present several case studies of GRM use, in order to illustrate its capabilities: identification of α-satellite tandem repeats and higher order repeats (HORs), identification of Alu dispersed repeats and of Alu tandems, identification of Period 3 pattern in exons, implementation of ‘magnifying glass’ effect, identification of complex HOR pattern, identification of inter-tandem transitional dispersed repeat sequences and identification of long segmental duplications. GRM algorithm is convenient for use, in particular, in cases of large repeat units, of highly mutated and/or complex repeats, and of global repeat maps for large genomic sequences (chromosomes and genomes). PMID:22977183

  7. Comprehensive analysis of all triple helical repeats in beta-spectrins reveals patterns of selective evolutionary conservation.

    PubMed

    Baines, Anthony J

    2003-01-01

    The spectrin superfamily (spectrin, alpha-actinin, utrophin and dystrophin) has in common a triple helical repeating unit of ~106 amino acid residues. In spectrin, alpha and beta chains contain multiple copies of this repeat. beta-spectrin chains contain the majority of binding activities in spectrin and are essential for animal life. Canonical beta-spectrins have 17 repeats; beta-heavy spectrins have 30. Here, the repeats of five human beta-spectrins, plus beta-spectrins from several other vertebrates and invertebrates, have been analysed. Repeats 1, 2, 14 and 17 in canonical beta are highly conserved between invertebrates and vertebrates, and repeat 8 in some isoforms. This is consistent with conservation of critical functions, since repeats 1, 2 and 17 bind alpha-spectrin. Repeats 1 of beta-spectrins are not always detected by SMART or Pfam tools. A profile hidden Markov model of beta-spectrin repeat 1 detects alpha-actinins, but not utrophin or dystrophin. Novel examples of repeat 1 were detected in the spectraplakins MACF1, BPAG1 and plectin close to the actin-binding domain. Ankyrin binds to the C-terminal portion of repeat 14; the high conservation of this entire repeat may point to additional, undiscovered ligand-binding activities. This analysis indicates that the basic triple helical repeat pattern was adapted early in the evolution of the spectrin superfamily to encompass essential binding activities, which characterise individual repeats in proteins extant today.

  8. A high-fidelity weather time series generator using the Markov Chain process on a piecewise level

    NASA Astrophysics Data System (ADS)

    Hersvik, K.; Endrerud, O.-E. V.

    2017-12-01

    A method is developed for generating a set of unique weather time-series based on an existing weather series. The method allows statistically valid weather variations to take place within repeated simulations of offshore operations. The numerous generated time series need to share the same statistical qualities as the original time series. Statistical qualities here refer mainly to the distribution of weather windows available for work, including durations and frequencies of such weather windows, and seasonal characteristics. The method is based on the Markov chain process. The core new development lies in how the Markov Process is used, specifically by joining small pieces of random length time series together rather than joining individual weather states, each from a single time step, which is a common solution found in the literature. This new Markov model shows favorable characteristics with respect to the requirements set forth and all aspects of the validation performed.

  9. Benchmarking heart rate variability toolboxes.

    PubMed

    Vest, Adriana N; Li, Qiao; Liu, Chengyu; Nemati, Shamim; Shah, Amit; Clifford, Gari D

    Heart rate variability (HRV) metrics hold promise as potential indicators for autonomic function, prediction of adverse cardiovascular outcomes, psychophysiological status, and general wellness. Although the investigation of HRV has been prevalent for several decades, the methods used for preprocessing, windowing, and choosing appropriate parameters lack consensus among academic and clinical investigators. A comprehensive and open-source modular program is presented for calculating HRV implemented in Matlab with evidence-based algorithms and output formats. We compare our software with another widely used HRV toolbox written in C and available through PhysioNet.org. Our findings show substantially similar results when using high quality electrocardiograms (ECG) free from arrhythmias. Our software shows equivalent performance alongside an established predecessor and includes validated tools for performing preprocessing, signal quality, and arrhythmia detection to help provide standardization and repeatability in the field, leading to fewer errors in the presence of noise or arrhythmias. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Dietary Protected Feed Supplement to Increase Milk Production and Quality of Dairy Cows

    NASA Astrophysics Data System (ADS)

    Pramono, A.; Handayanta, E.; Widayati, D. T.; Putro, P. P.; Kustono

    2017-04-01

    The efforts to improve and optimize productivity of dairy cows require sufficient availability of nutrients, especially high energy in the early period of lactation. Increasing energy intake in dairy cows can be conducted by increasing the density of energy. The research aimed to evaluate dietary protected feed supplement on milk production and quality, including: fat, protein, and lactose content of Friesian Holstein dairy cow milk. Protected feed supplement was produced from sardine fish oil, through saponification and microencapsulation protection methods. The experiment consists of two treatments i.e. P0: basal diet (control) and P1: basal diet + 3 % protected feed supplement. Each treatment was repeated 15 times. Data were analyzed by independent samples t-test analysis. Results showed that supplementation of protected sardine fish oil had no effect on lactose content, but increased milk yield production (p<0.01), milk fat content (p<0.05), and protein content (p<0.05).

  11. Developing a more useful surface quality metric for laser optics

    NASA Astrophysics Data System (ADS)

    Turchette, Quentin; Turner, Trey

    2011-02-01

    Light scatter due to surface defects on laser resonator optics produces losses which lower system efficiency and output power. The traditional methodology for surface quality inspection involves visual comparison of a component to scratch and dig (SAD) standards under controlled lighting and viewing conditions. Unfortunately, this process is subjective and operator dependent. Also, there is no clear correlation between inspection results and the actual performance impact of the optic in a laser resonator. As a result, laser manufacturers often overspecify surface quality in order to ensure that optics will not degrade laser performance due to scatter. This can drive up component costs and lengthen lead times. Alternatively, an objective test system for measuring optical scatter from defects can be constructed with a microscope, calibrated lighting, a CCD detector and image processing software. This approach is quantitative, highly repeatable and totally operator independent. Furthermore, it is flexible, allowing the user to set threshold levels as to what will or will not constitute a defect. This paper details how this automated, quantitative type of surface quality measurement can be constructed, and shows how its results correlate against conventional loss measurement techniques such as cavity ringdown times.

  12. Assessment of Reference Height Models on Quality of Tandem-X dem

    NASA Astrophysics Data System (ADS)

    Mirzaee, S.; Motagh, M.; Arefi, H.

    2015-12-01

    The aim of this study is to investigate the effect of various Global Digital Elevation Models (GDEMs) in producing high-resolution topography model using TanDEM-X (TDX) Coregistered Single Look Slant Range Complex (CoSSC) images. We selected an image acquired on Jun 12th, 2012 over Doroud region in Lorestan, west of Iran and used 4 external digital elevation models in our processing including DLR/ASI X-SAR DEM (SRTM-X, 30m resolution), ASTER GDEM Version 2 (ASTER-GDEMV2, 30m resolution), NASA SRTM Version 4 (SRTM-V4, 90m resolution), and a local photogrammetry-based DEM prepared by National Cartographic Center (NCC DEM, 10m resolution) of Iran. InSAR procedure for DEM generation was repeated four times with each of the four external height references. The quality of each external DEM was initially assessed using ICESat filtered points. Then, the quality of, each TDX-based DEM was assessed using the more precise external DEM selected in the previous step. Results showed that both local (NCC) DEM and SRTM X-band performed the best (RMSE< 9m) for TDX-DEM generation. In contrast, ASTER GDEM v2 and SRTM C-band v4 showed poorer quality.

  13. Bridging the Research-to-Practice Gap in Education: A Software-Mediated Approach for Improving Classroom Instruction

    ERIC Educational Resources Information Center

    Weston, Mark E.; Bain, Alan

    2015-01-01

    This study reports findings from a matched-comparison, repeated-measure for intact groups design of the mediating effect of a suite of software on the quality of classroom instruction provided to students by teachers. The quality of instruction provided by teachers in the treatment and control groups was documented via observations that were…

  14. Understory vegetation data quality assessment for the Interior West Forest and Inventory Analysis program

    Treesearch

    Paul L. Patterson; Renee A. O' Brien

    2011-01-01

    The Interior West Forest Inventory and Analysis (IW-FIA) program of the USDA Forest Service collects field data on understory vegetation structure that have broad applications. In IW-FIA one aspect of quality assurance is assessed based on the repeatability of field measurements. The understory vegetation protocol consists of two suites of measurements; (1) the...

  15. Leader-member exchange: Moderating the health and safety outcomes of job insecurity.

    PubMed

    Probst, Tahira M; Jiang, Lixin; Graso, Maja

    2016-02-01

    Job insecurity has been repeatedly linked with poor employee health and safety outcomes. Although research on high quality leader-member exchange (LMX) has demonstrated many beneficial effects, no research to date has examined the extent to which positive LMX might attenuate those adverse health and safety-related consequences of job insecurity. The current study extends research in this area by specifically examining the buffering impact of LMX on the relationship between job insecurity and safety knowledge, reported accidents, and physical health conditions. Furthermore, the study also examines whether positive LMX mitigates the typically seen negative impact of job insecurity on supervisor satisfaction. The hypotheses were tested using survey data collected from 212 employees of a mine located in southwestern United States. As predicted, job insecurity was related to lower levels of supervisor satisfaction, more health ailments, and more workplace accidents, and was marginally related to lower levels of safety knowledge. Results indicated that LMX significantly attenuated these observed relationships. The quality of the dyadic relationship between supervisor and subordinate has a significant impact on the extent to which job insecurity is associated with adverse health and safety outcomes. Practical implications for supervisor behavior and developing high quality LMX are discussed in light of today's pervasive job insecurity. Copyright © 2015 Elsevier Ltd and National Safety Council. All rights reserved.

  16. TU-C-12A-05: Repeatability Study of Reduced Field-Of-View Diffusion-Weighted MRI On Human Thyroid Gland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shukla-Dave, A; Lu, Y; Hatzoglou, V

    2014-06-15

    Purpose: To investigate the repeatability of reduced field-of-view diffusion-weighted imaging (rFOV DWI) in quantifying apparent diffusion coefficients (ADCs) for human thyroid glands in a clinical setting. Methods: Nine healthy human volunteers were enrolled and underwent 3T MRI exams. For each volunteer, 3 longitudinal exams (2 weeks apart) with 2 repetitive sessions within each exam, including rFOV and conventional full field-of-view (fFOV) DWI scans, were performed. In the acquired DWI images, a fixed-size region of interest (ROI; diameter=8mm) was placed on thyroid glands to calculate ADC. ADC was calculated using a monoexponential function with a noise correction scheme. The repeatability ofmore » ADC was assessed by using coefficient variation (CV) across sessions or exams, which was defined to be: r = 1-CV, 0 < r < 1, where CV=STD/m, STD is the standard deviation of ADC, and m is the average of ADC across sessions or exams. An experienced radiologist assessed and scored rFOV and fFOV DW images based on image characteristics (1, nondiagnostic; 2, poor; 3, satisfactory; 4, good; and 5, excellent).Analysis of variance (ANOVA) was performed to compare ADC values, CV of ADC, repeatability of ADC across sessions and exams, and radiologic scores between rFOV and fFOV DWI techniques. Results: There was no significant difference in ADC values across sessions and exams either in rFOV or fFOV DWI. The average CVs of both rFOV and fFOV DWI were less than 13%. The repeatability of ADC measurement between rFOV and fFOV DWI was not significantly different. The overall image quality was significantly higher with rFOV DWI than with fFOV DWI. Conclusion: This study suggested that ADCs from both rFOV and fFOV DWI were repeatable, but rFOV DWI had superior imaging quality for human thyroid glands in a clinical setting.« less

  17. Automated quality checks on repeat prescribing.

    PubMed Central

    Rogers, Jeremy E; Wroe, Christopher J; Roberts, Angus; Swallow, Angela; Stables, David; Cantrill, Judith A; Rector, Alan L

    2003-01-01

    BACKGROUND: Good clinical practice in primary care includes periodic review of repeat prescriptions. Markers of prescriptions that may need review have been described, but manually checking all repeat prescriptions against the markers would be impractical. AIM: To investigate the feasibility of computerising the application of repeat prescribing quality checks to electronic patient records in United Kingdom (UK) primary care. DESIGN OF STUDY: Software performance test against benchmark manual analysis of cross-sectional convenience sample of prescribing documentation. SETTING: Three general practices in Greater Manchester, in the north west of England, during a 4-month period in 2001. METHOD: A machine-readable drug information resource, based on the British National Formulary (BNF) as the 'gold standard' for valid drug indications, was installed in three practices. Software raised alerts for each repeat prescribed item where the electronic patient record contained no valid indication for the medication. Alerts raised by the software in two practices were analysed manually. Clinical reaction to the software was assessed by semi-structured interviews in three practices. RESULTS: There was no valid indication in the electronic medical records for 14.8% of repeat prescribed items. Sixty-two per cent of all alerts generated were incorrect. Forty-three per cent of all incorrect alerts were as a result of errors in the drug information resource, 44% to locally idiosyncratic clinical coding, 8% to the use of the BNF without adaptation as a gold standard, and 5% to the inability of the system to infer diagnoses that, although unrecorded, would be 'obvious' to a clinical reading the record. The interviewed clinicians supported the goals of the software. CONCLUSION: Using electronic records for secondary decision support purposes will benefit from (and may require) both more consistent electronic clinical data collection across multiple sites, and reconciling clinicians' willingness to infer unstated but 'obvious' diagnoses with the machine's inability to do the same. PMID:14702902

  18. Effects of allelic variations in starch synthesis-related genes on grain quality traits of Korean nonglutinous rice varieties under different temperature conditions

    PubMed Central

    Mo, Young-Jun; Jeung, Ji-Ung; Shin, Woon-Chul; Kim, Ki-Young; Ye, Changrong; Redoña, Edilberto D.; Kim, Bo-Kyeong

    2014-01-01

    Influences of allelic variations in starch synthesis-related genes (SSRGs) on rice grain quality were examined. A total of 187 nonglutinous Korean rice varieties, consisting of 170 Japonica and 17 Tongil-type varieties, were grown in the field and in two greenhouse conditions. The percentages of head rice and chalky grains, amylose content, alkali digestion value, and rapid visco-analysis characteristics were evaluated in the three different environments. Among the 10 previously reported SSRG markers used in this study, seven were polymorphic, and four of those showed subspecies-specific allele distributions. Six out of the seven polymorphic SSRG markers were significantly associated with at least one grain quality trait (R2 > 0.1) across the three different environments. However, the association level and significance were markedly lower when the analysis was repeated using only the 170 Japonica varieties. Similarly, the significant associations between SSRG allelic variations and changes in grain quality traits under increased temperature were largely attributable to the biased allele frequency between the two subpopulations. Our results suggest that within Korean Japonica varieties, these 10 major SSRG loci have been highly fixed during breeding history and variations in grain quality traits might be influenced by other genetic factors. PMID:24987303

  19. Demonstration of repeatability in a high-energy-density planar shear mixing layer experiment

    DOE PAGES

    Merritt, Elizabeth Catherine; Doss, Forrest William; Di Stefano, Carlos A.; ...

    2017-03-11

    On laser-driven platforms the assumption of experiment repeatability is particularly important due to a typically low data acquisition rate that doesn’t often allow for data redundancy. If the platform is repeatable, then measurements of the repeatable dynamics from multiple experiments can be treated as measurements of the same system. In high-energy-density hydrodynamic instability experiments the interface growth is assumed to be one of the repeatable aspects of the system. In this paper we demonstrate the repeatability of the instability growth in the counter-propagating shear experiment at the OMEGA laser facility, where the instability growth is characterized by the tracer layermore » thickness or mix-width evolution. Furthermore, in our previous experiment campaigns we have assumed the instability growth was repeatable enough to identify trends, but in this work we explicitly show that the mix-width measurements for nominally identical experiments are repeatable within the measurement error bars.« less

  20. Rapid cloning of genes in hexaploid wheat using cultivar-specific long-range chromosome assembly.

    PubMed

    Thind, Anupriya Kaur; Wicker, Thomas; Šimková, Hana; Fossati, Dario; Moullet, Odile; Brabant, Cécile; Vrána, Jan; Doležel, Jaroslav; Krattinger, Simon G

    2017-08-01

    Cereal crops such as wheat and maize have large repeat-rich genomes that make cloning of individual genes challenging. Moreover, gene order and gene sequences often differ substantially between cultivars of the same crop species. A major bottleneck for gene cloning in cereals is the generation of high-quality sequence information from a cultivar of interest. In order to accelerate gene cloning from any cropping line, we report 'targeted chromosome-based cloning via long-range assembly' (TACCA). TACCA combines lossless genome-complexity reduction via chromosome flow sorting with Chicago long-range linkage to assemble complex genomes. We applied TACCA to produce a high-quality (N50 of 9.76 Mb) de novo chromosome assembly of the wheat line CH Campala Lr22a in only 4 months. Using this assembly we cloned the broad-spectrum Lr22a leaf-rust resistance gene, using molecular marker information and ethyl methanesulfonate (EMS) mutants, and found that Lr22a encodes an intracellular immune receptor homologous to the Arabidopsis thaliana RPM1 protein.

  1. Direct growth of freestanding GaN on C-face SiC by HVPE.

    PubMed

    Tian, Yuan; Shao, Yongliang; Wu, Yongzhong; Hao, Xiaopeng; Zhang, Lei; Dai, Yuanbin; Huo, Qin

    2015-06-02

    In this work, high quality GaN crystal was successfully grown on C-face 6H-SiC by HVPE using a two steps growth process. Due to the small interaction stress between the GaN and the SiC substrate, the GaN was self-separated from the SiC substrate even with a small thickness of about 100 μm. Moreover, the SiC substrate was excellent without damage after the whole process so that it can be repeatedly used in the GaN growth. Hot phosphoric acid etching (at 240 °C for 30 min) was employed to identify the polarity of the GaN layer. According to the etching results, the obtained layer was Ga-polar GaN. High-resolution X-ray diffraction (HRXRD) and electron backscatter diffraction (EBSD) were done to characterize the quality of the freestanding GaN. The Raman measurements showed that the freestanding GaN film grown on the C-face 6H-SiC was stress-free. The optical properties of the freestanding GaN layer were determined by photoluminescence (PL) spectra.

  2. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  3. Targeting of Repeated Sequences Unique to a Gene Results in Significant Increases in Antisense Oligonucleotide Potency

    PubMed Central

    Vickers, Timothy A.; Freier, Susan M.; Bui, Huynh-Hoa; Watt, Andrew; Crooke, Stanley T.

    2014-01-01

    A new strategy for identifying potent RNase H-dependent antisense oligonucleotides (ASOs) is presented. Our analysis of the human transcriptome revealed that a significant proportion of genes contain unique repeated sequences of 16 or more nucleotides in length. Activities of ASOs targeting these repeated sites in several representative genes were compared to those of ASOs targeting unique single sites in the same transcript. Antisense activity at repeated sites was also evaluated in a highly controlled minigene system. Targeting both native and minigene repeat sites resulted in significant increases in potency as compared to targeting of non-repeated sites. The increased potency at these sites is a result of increased frequency of ASO/RNA interactions which, in turn, increases the probability of a productive interaction between the ASO/RNA heteroduplex and human RNase H1 in the cell. These results suggest a new, highly efficient strategy for rapid identification of highly potent ASOs. PMID:25334092

  4. The zebrafish reference genome sequence and its relationship to the human genome.

    PubMed

    Howe, Kerstin; Clark, Matthew D; Torroja, Carlos F; Torrance, James; Berthelot, Camille; Muffato, Matthieu; Collins, John E; Humphray, Sean; McLaren, Karen; Matthews, Lucy; McLaren, Stuart; Sealy, Ian; Caccamo, Mario; Churcher, Carol; Scott, Carol; Barrett, Jeffrey C; Koch, Romke; Rauch, Gerd-Jörg; White, Simon; Chow, William; Kilian, Britt; Quintais, Leonor T; Guerra-Assunção, José A; Zhou, Yi; Gu, Yong; Yen, Jennifer; Vogel, Jan-Hinnerk; Eyre, Tina; Redmond, Seth; Banerjee, Ruby; Chi, Jianxiang; Fu, Beiyuan; Langley, Elizabeth; Maguire, Sean F; Laird, Gavin K; Lloyd, David; Kenyon, Emma; Donaldson, Sarah; Sehra, Harminder; Almeida-King, Jeff; Loveland, Jane; Trevanion, Stephen; Jones, Matt; Quail, Mike; Willey, Dave; Hunt, Adrienne; Burton, John; Sims, Sarah; McLay, Kirsten; Plumb, Bob; Davis, Joy; Clee, Chris; Oliver, Karen; Clark, Richard; Riddle, Clare; Elliot, David; Eliott, David; Threadgold, Glen; Harden, Glenn; Ware, Darren; Begum, Sharmin; Mortimore, Beverley; Mortimer, Beverly; Kerry, Giselle; Heath, Paul; Phillimore, Benjamin; Tracey, Alan; Corby, Nicole; Dunn, Matthew; Johnson, Christopher; Wood, Jonathan; Clark, Susan; Pelan, Sarah; Griffiths, Guy; Smith, Michelle; Glithero, Rebecca; Howden, Philip; Barker, Nicholas; Lloyd, Christine; Stevens, Christopher; Harley, Joanna; Holt, Karen; Panagiotidis, Georgios; Lovell, Jamieson; Beasley, Helen; Henderson, Carl; Gordon, Daria; Auger, Katherine; Wright, Deborah; Collins, Joanna; Raisen, Claire; Dyer, Lauren; Leung, Kenric; Robertson, Lauren; Ambridge, Kirsty; Leongamornlert, Daniel; McGuire, Sarah; Gilderthorp, Ruth; Griffiths, Coline; Manthravadi, Deepa; Nichol, Sarah; Barker, Gary; Whitehead, Siobhan; Kay, Michael; Brown, Jacqueline; Murnane, Clare; Gray, Emma; Humphries, Matthew; Sycamore, Neil; Barker, Darren; Saunders, David; Wallis, Justene; Babbage, Anne; Hammond, Sian; Mashreghi-Mohammadi, Maryam; Barr, Lucy; Martin, Sancha; Wray, Paul; Ellington, Andrew; Matthews, Nicholas; Ellwood, Matthew; Woodmansey, Rebecca; Clark, Graham; Cooper, James D; Cooper, James; Tromans, Anthony; Grafham, Darren; Skuce, Carl; Pandian, Richard; Andrews, Robert; Harrison, Elliot; Kimberley, Andrew; Garnett, Jane; Fosker, Nigel; Hall, Rebekah; Garner, Patrick; Kelly, Daniel; Bird, Christine; Palmer, Sophie; Gehring, Ines; Berger, Andrea; Dooley, Christopher M; Ersan-Ürün, Zübeyde; Eser, Cigdem; Geiger, Horst; Geisler, Maria; Karotki, Lena; Kirn, Anette; Konantz, Judith; Konantz, Martina; Oberländer, Martina; Rudolph-Geiger, Silke; Teucke, Mathias; Lanz, Christa; Raddatz, Günter; Osoegawa, Kazutoyo; Zhu, Baoli; Rapp, Amanda; Widaa, Sara; Langford, Cordelia; Yang, Fengtang; Schuster, Stephan C; Carter, Nigel P; Harrow, Jennifer; Ning, Zemin; Herrero, Javier; Searle, Steve M J; Enright, Anton; Geisler, Robert; Plasterk, Ronald H A; Lee, Charles; Westerfield, Monte; de Jong, Pieter J; Zon, Leonard I; Postlethwait, John H; Nüsslein-Volhard, Christiane; Hubbard, Tim J P; Roest Crollius, Hugues; Rogers, Jane; Stemple, Derek L

    2013-04-25

    Zebrafish have become a popular organism for the study of vertebrate gene function. The virtually transparent embryos of this species, and the ability to accelerate genetic studies by gene knockdown or overexpression, have led to the widespread use of zebrafish in the detailed investigation of vertebrate gene function and increasingly, the study of human genetic disease. However, for effective modelling of human genetic disease it is important to understand the extent to which zebrafish genes and gene structures are related to orthologous human genes. To examine this, we generated a high-quality sequence assembly of the zebrafish genome, made up of an overlapping set of completely sequenced large-insert clones that were ordered and oriented using a high-resolution high-density meiotic map. Detailed automatic and manual annotation provides evidence of more than 26,000 protein-coding genes, the largest gene set of any vertebrate so far sequenced. Comparison to the human reference genome shows that approximately 70% of human genes have at least one obvious zebrafish orthologue. In addition, the high quality of this genome assembly provides a clearer understanding of key genomic features such as a unique repeat content, a scarcity of pseudogenes, an enrichment of zebrafish-specific genes on chromosome 4 and chromosomal regions that influence sex determination.

  5. The zebrafish reference genome sequence and its relationship to the human genome

    PubMed Central

    Howe, Kerstin; Clark, Matthew D.; Torroja, Carlos F.; Torrance, James; Berthelot, Camille; Muffato, Matthieu; Collins, John E.; Humphray, Sean; McLaren, Karen; Matthews, Lucy; McLaren, Stuart; Sealy, Ian; Caccamo, Mario; Churcher, Carol; Scott, Carol; Barrett, Jeffrey C.; Koch, Romke; Rauch, Gerd-Jörg; White, Simon; Chow, William; Kilian, Britt; Quintais, Leonor T.; Guerra-Assunção, José A.; Zhou, Yi; Gu, Yong; Yen, Jennifer; Vogel, Jan-Hinnerk; Eyre, Tina; Redmond, Seth; Banerjee, Ruby; Chi, Jianxiang; Fu, Beiyuan; Langley, Elizabeth; Maguire, Sean F.; Laird, Gavin K.; Lloyd, David; Kenyon, Emma; Donaldson, Sarah; Sehra, Harminder; Almeida-King, Jeff; Loveland, Jane; Trevanion, Stephen; Jones, Matt; Quail, Mike; Willey, Dave; Hunt, Adrienne; Burton, John; Sims, Sarah; McLay, Kirsten; Plumb, Bob; Davis, Joy; Clee, Chris; Oliver, Karen; Clark, Richard; Riddle, Clare; Eliott, David; Threadgold, Glen; Harden, Glenn; Ware, Darren; Mortimer, Beverly; Kerry, Giselle; Heath, Paul; Phillimore, Benjamin; Tracey, Alan; Corby, Nicole; Dunn, Matthew; Johnson, Christopher; Wood, Jonathan; Clark, Susan; Pelan, Sarah; Griffiths, Guy; Smith, Michelle; Glithero, Rebecca; Howden, Philip; Barker, Nicholas; Stevens, Christopher; Harley, Joanna; Holt, Karen; Panagiotidis, Georgios; Lovell, Jamieson; Beasley, Helen; Henderson, Carl; Gordon, Daria; Auger, Katherine; Wright, Deborah; Collins, Joanna; Raisen, Claire; Dyer, Lauren; Leung, Kenric; Robertson, Lauren; Ambridge, Kirsty; Leongamornlert, Daniel; McGuire, Sarah; Gilderthorp, Ruth; Griffiths, Coline; Manthravadi, Deepa; Nichol, Sarah; Barker, Gary; Whitehead, Siobhan; Kay, Michael; Brown, Jacqueline; Murnane, Clare; Gray, Emma; Humphries, Matthew; Sycamore, Neil; Barker, Darren; Saunders, David; Wallis, Justene; Babbage, Anne; Hammond, Sian; Mashreghi-Mohammadi, Maryam; Barr, Lucy; Martin, Sancha; Wray, Paul; Ellington, Andrew; Matthews, Nicholas; Ellwood, Matthew; Woodmansey, Rebecca; Clark, Graham; Cooper, James; Tromans, Anthony; Grafham, Darren; Skuce, Carl; Pandian, Richard; Andrews, Robert; Harrison, Elliot; Kimberley, Andrew; Garnett, Jane; Fosker, Nigel; Hall, Rebekah; Garner, Patrick; Kelly, Daniel; Bird, Christine; Palmer, Sophie; Gehring, Ines; Berger, Andrea; Dooley, Christopher M.; Ersan-Ürün, Zübeyde; Eser, Cigdem; Geiger, Horst; Geisler, Maria; Karotki, Lena; Kirn, Anette; Konantz, Judith; Konantz, Martina; Oberländer, Martina; Rudolph-Geiger, Silke; Teucke, Mathias; Osoegawa, Kazutoyo; Zhu, Baoli; Rapp, Amanda; Widaa, Sara; Langford, Cordelia; Yang, Fengtang; Carter, Nigel P.; Harrow, Jennifer; Ning, Zemin; Herrero, Javier; Searle, Steve M. J.; Enright, Anton; Geisler, Robert; Plasterk, Ronald H. A.; Lee, Charles; Westerfield, Monte; de Jong, Pieter J.; Zon, Leonard I.; Postlethwait, John H.; Nüsslein-Volhard, Christiane; Hubbard, Tim J. P.; Crollius, Hugues Roest; Rogers, Jane; Stemple, Derek L.

    2013-01-01

    Zebrafish have become a popular organism for the study of vertebrate gene function1,2. The virtually transparent embryos of this species, and the ability to accelerate genetic studies by gene knockdown or overexpression, have led to the widespread use of zebrafish in the detailed investigation of vertebrate gene function and increasingly, the study of human genetic disease3–5. However, for effective modelling of human genetic disease it is important to understand the extent to which zebrafish genes and gene structures are related to orthologous human genes. To examine this, we generated a high-quality sequence assembly of the zebrafish genome, made up of an overlapping set of completely sequenced large-insert clones that were ordered and oriented using a high-resolution high-density meiotic map. Detailed automatic and manual annotation provides evidence of more than 26,000 protein-coding genes6, the largest gene set of any vertebrate so far sequenced. Comparison to the human reference genome shows that approximately 70% of human genes have at least one obvious zebrafish orthologue. In addition, the high quality of this genome assembly provides a clearer understanding of key genomic features such as a unique repeat content, a scarcity of pseudogenes, an enrichment of zebrafish-specific genes on chromosome 4 and chromosomal regions that influence sex determination. PMID:23594743

  6. Verifying Data Integrity of Electronically Scanned Pressure Systems at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Panek, Joseph W.

    2001-01-01

    The proper operation of the Electronically Scanned Pressure (ESP) System critical to accomplish the following goals: acquisition of highly accurate pressure data for the development of aerospace and commercial aviation systems and continuous confirmation of data quality to avoid costly, unplanned, repeat wind tunnel or turbine testing. Standard automated setup and checkout routines are necessary to accomplish these goals. Data verification and integrity checks occur at three distinct stages, pretest pressure tubing and system checkouts, daily system validation and in-test confirmation of critical system parameters. This paper will give an overview of the existing hardware, software and methods used to validate data integrity.

  7. Revalidation of the NASA Ames 11-by 11-Foot Transonic Wind Tunnel with a Commercial Airplane Model

    NASA Technical Reports Server (NTRS)

    Kmak, Frank J.; Hudgins, M.; Hergert, D.; George, Michael W. (Technical Monitor)

    2001-01-01

    The 11-By 11-Foot Transonic leg of the Unitary Plan Wind Tunnel (UPWT) was modernized to improve tunnel performance, capability, productivity, and reliability. Wind tunnel tests to demonstrate the readiness of the tunnel for a return to production operations included an Integrated Systems Test (IST), calibration tests, and airplane validation tests. One of the two validation tests was a 0.037-scale Boeing 777 model that was previously tested in the 11-By 11-Foot tunnel in 1991. The objective of the validation tests was to compare pre-modernization and post-modernization results from the same airplane model in order to substantiate the operational readiness of the facility. Evaluation of within-test, test-to-test, and tunnel-to-tunnel data repeatability were made to study the effects of the tunnel modifications. Tunnel productivity was also evaluated to determine the readiness of the facility for production operations. The operation of the facility, including model installation, tunnel operations, and the performance of tunnel systems, was observed and facility deficiency findings generated. The data repeatability studies and tunnel-to-tunnel comparisons demonstrated outstanding data repeatability and a high overall level of data quality. Despite some operational and facility problems, the validation test was successful in demonstrating the readiness of the facility to perform production airplane wind tunnel%, tests.

  8. Varietal Discrimination and Genetic Variability Analysis of Cymbopogon Using RAPD and ISSR Markers Analysis.

    PubMed

    Bishoyi, Ashok Kumar; Sharma, Anjali; Kavane, Aarti; Geetha, K A

    2016-06-01

    Cymbopogon is an important genus of family Poaceae, cultivated mainly for its essential oils which possess high medicinal and economical value. Several cultivars of Cymbopogon species are available for commercial cultivation in India and identification of these cultivars was conceded by means of morphological markers and essential oil constitution. Since these parameters are highly influenced by environmental factors, in most of the cases, it is difficult to identify Cymbopogon cultivars. In the present study, Random amplified polymorphic DNA (RAPD) and Inter-simple sequence repeat (ISSR) markers were employed to discriminate nine leading varieties of Cymbopogon since prior genomic information is lacking or very little in the genus. Ninety RAPD and 70 ISSR primers were used which generated 63 and 69 % polymorphic amplicons, respectively. Similarity in the pattern of UPGMA-derived dendrogram of RAPD and ISSR analysis revealed the reliability of the markers chosen for the study. Varietal/cultivar-specific markers generated from the study could be utilised for varietal/cultivar authentication, thus monitoring the quality of the essential oil production in Cymbopogon. These markers can also be utilised for the IPR protection of the cultivars. Moreover, the study provides molecular marker tool kit in both random and simple sequence repeats for diverse molecular research in the same or related genera.

  9. Preliminary experience of a PDCA-cycle and quality management based training curriculum for rat liver transplantation.

    PubMed

    Jin, Hao; Huang, Hai; Dong, Wei; Sun, Jian; Liu, Anding; Deng, Meihong; Dirsch, Olaf; Dahmen, Uta

    2012-08-01

    As repeatedly operating rat liver transplantation (LTx) until animals survive is inefficient in respect to time and use of living animals, we developed a new training concept. METHODS AND CONCEPTS: Training was divided into four phases: pretraining-phase, basic-microsurgical-training phase, advanced-microsurgical-training phases, and expert-microsurgical-training phase. Two "productivity-phases" were introduced right after the basic- and advanced-microsurgical-training phases, respectively, to allow the trainee to accumulate experience and to be scientifically productive before proceeding to a more complex procedure. PDCA cycles and quality criteria were employed to control the learning-process and the surgical quality. Predefined quality criteria included survival rate, intraoperative, postoperative, and histologic parameters. Three trainees participated in the LTx training and achieved their first survival record within 4-10 operations. All of them completely mastered the LTx in fewer procedures (31, 60 and 26 procedures) as reported elsewhere, and the more complex arterialized or partial LTx were mastered by trainee A and B in additional 9 and 13 procedures, respectively. Fast progress was possible due to a high number of training in the 2 Productivity-phases. The stepwise and PDCA-based training program increased the efficiency of LTx training, whereas the constant application and development of predefined quality criteria guaranteed the quality of microsurgery. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Strategies for optimizing BioNano and Dovetail explored through a second reference quality assembly for the legume model, Medicago truncatula.

    PubMed

    Moll, Karen M; Zhou, Peng; Ramaraj, Thiruvarangan; Fajardo, Diego; Devitt, Nicholas P; Sadowsky, Michael J; Stupar, Robert M; Tiffin, Peter; Miller, Jason R; Young, Nevin D; Silverstein, Kevin A T; Mudge, Joann

    2017-08-04

    Third generation sequencing technologies, with sequencing reads in the tens- of kilo-bases, facilitate genome assembly by spanning ambiguous regions and improving continuity. This has been critical for plant genomes, which are difficult to assemble due to high repeat content, gene family expansions, segmental and tandem duplications, and polyploidy. Recently, high-throughput mapping and scaffolding strategies have further improved continuity. Together, these long-range technologies enable quality draft assemblies of complex genomes in a cost-effective and timely manner. Here, we present high quality genome assemblies of the model legume plant, Medicago truncatula (R108) using PacBio, Dovetail Chicago (hereafter, Dovetail) and BioNano technologies. To test these technologies for plant genome assembly, we generated five assemblies using all possible combinations and ordering of these three technologies in the R108 assembly. While the BioNano and Dovetail joins overlapped, they also showed complementary gains in continuity and join numbers. Both technologies spanned repetitive regions that PacBio alone was unable to bridge. Combining technologies, particularly Dovetail followed by BioNano, resulted in notable improvements compared to Dovetail or BioNano alone. A combination of PacBio, Dovetail, and BioNano was used to generate a high quality draft assembly of R108, a M. truncatula accession widely used in studies of functional genomics. As a test for the usefulness of the resulting genome sequence, the new R108 assembly was used to pinpoint breakpoints and characterize flanking sequence of a previously identified translocation between chromosomes 4 and 8, identifying more than 22.7 Mb of novel sequence not present in the earlier A17 reference assembly. Adding Dovetail followed by BioNano data yielded complementary improvements in continuity over the original PacBio assembly. This strategy proved efficient and cost-effective for developing a quality draft assembly compared to traditional reference assemblies.

  11. Design of an interventional magnetic resonance imaging coil for cerebral surgery

    NASA Astrophysics Data System (ADS)

    Xu, Yue; Wang, Wen-Tao; Wang, Wei-Min

    2012-11-01

    In clinical magnetic resonance imaging (MRI), the design of the radiofrequency (RF) coil is very important. For certain applications, the appropriate coil can produce an improved image quality. However, it is difficult to achieve a uniform B1 field and a high signal-to-noise ratio (SNR) simultaneously. In this article, we design an interventional transmitter-and-receiver RF coil for cerebral surgery. This coil adopts a disassembly structure that can be assembled and disassembled repeatedly on the cerebral surgery gantry to reduce the amount of interference from the MRI during surgery. The simulation results and the imaging experiments demonstrate that this coil can produce a uniform RF field, a high SNR, and a large imaging range to meet the requirements of the cerebral surgery.

  12. Comparison of the impact on health-related quality of life of repeated detrusor injections of botulinum toxin in patients with idiopathic or neurogenic detrusor overactivity.

    PubMed

    Gamé, Xavier; Khan, Shahid; Panicker, Jalesh N; Kalsi, Vinay; Dalton, Catherine; Elneil, Sohier; Hamid, Rizwan; Dasgupta, Prokar; Fowler, Clare J

    2011-06-01

    Therapy (case series). 4. What's known on the subject? and What does the study add? We know that repeated injections of botulinum toxin A are effective in treating refractory detrusor overactivity particularly in NDO. This study shows that in both NDO and IDO repeated injections of the toxin improve quality of life as assessed by three validated questionnaires. The effect is most marked after the first injection in NDO patients but thereafter similar in both groups. To compare the effect of repeated detrusor injections of botulinum toxin (BoNT-A) on health-related quality of life (HRQL) in patients with idiopathic (IDO) or neurogenic detrusor overactivity (NDO). Between 2003 and 2009, 151 patients (109 with NDO and 42 with IDO) were treated by BoNT-A (Botox®, Allergan Inc., Irvine, CA, USA). Changes in HRQL were assessed using the validated short forms of Urogenital Distress Inventory (UDI-6), the Incontinence Impact Questionnaire (IIQ-7) and EuroQOL-5D (EQ-5D) before and 4 weeks after BoNT-A. The maximum number of repeated injections was five (mean±sd, 2.8±1.05). Mean±sd follow-up was 27.49±17.01 months. The UDI-6 and IIQ-7 questionnaires showed a consistent improvement after repeated injections in both groups with detrusor overactivity. The EQ-5D was not statistically different before and after each injection in either the NDO or IDO population. After repeated injections, no statistical differences in the change on the UDI-6 and IIQ-7 scores were found between NDO and IDO, except after the first treatment, when the decrease in UDI-6 was higher in NDO than in IDO. The EQ-5D anxiety and depression subscore improved in both groups after each injection and with the number of injections. In IDO, after the second injection, no patient reported extreme anxiety or depression and, after the fourth injection, none had anxiety or depression. The inter-injection interval was shorter after the first injection in those with NDO than in IDO but was similar thereafter. Intradetrusor injections of BoNT-A improved the HRQL of both NDO and IDO patients. Although improvement in HRQL was greater and the duration of efficacy shorter in NDO patients after the first injection, there was no significant difference after subsequent injections. Mean inter-injection interval in IDO and in NDO patients was similar from the second injection onwards and improvements in HRQL score were the same. © 2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.

  13. Repeated exposure to high-frequency spanking and child externalizing behavior across the first decade: a moderating role for cumulative risk.

    PubMed

    MacKenzie, Michael J; Nicklas, Eric; Brooks-Gunn, Jeanne; Waldfogel, Jane

    2014-12-01

    This study used the Fragile Families and Child Well-Being Study to examine the effects of repeated exposure to harsh parenting on child externalizing behavior across the first decade of life, and a moderating role for cumulative ecological risk. Maternal report of harsh parenting, defined as high frequency spanking, was assessed at age 1, 3, 5, and 9, along with child externalizing at age 9 (N=2,768). Controlling for gender, race, maternal nativity, and city of residence, we found a cumulative risk index to significantly moderate the effects of repeated harsh parenting on child behavior, with the effects of repeated high-frequency spanking being amplified for those experiencing greater levels of cumulative risk. Harsh parenting, in the form of high frequency spanking, remains a too common experience for children, and results demonstrate that the effects of repeated exposure to harsh parenting across the first decade are amplified for those children already facing the most burden. Copyright © 2014. Published by Elsevier Ltd.

  14. Repeated exposure to high-frequency spanking and child externalizing behavior across the first decade: A moderating role for cumulative risk

    PubMed Central

    MacKenzie, Michael J.; Nicklas, Eric; Brooks-Gunn, Jeanne; Waldfogel, Jane

    2016-01-01

    This study used the Fragile Families and Child Well-being study to examine the effects of repeated exposure to harsh parenting on child externalizing behavior across the first decade of life, and a moderating role for cumulative ecological risk. Maternal report of harsh parenting, defined as high frequency spanking, was assessed at age 1, 3, 5, and 9, along with child externalizing at age 9 (N=2768). Controlling for gender, race, maternal nativity, and city of residence, we found a cumulative risk index to significantly moderate the effects of repeated harsh parenting on child behavior, with the effects of repeated high-frequency spanking being amplified for those experiencing greater levels of cumulative risk. Harsh parenting, in the form of high frequency spanking, remains a too common experience for children, and results demonstrate that the effects of repeated exposure to harsh parenting across the first decade are amplified for those children already facing the most burden. PMID:25465318

  15. The organizational attraction of nursing graduates: using research to guide employer branding.

    PubMed

    Fréchette, Julie; Bourhis, Anne; Stachura, Michal

    2013-01-01

    In the context of the global nursing shortage, only the most attractive employers are able to recruit a sufficient number of nurses to maintain high quality of care and ensure positive patient outcomes. It is important for health care organizations to align their practices and their employer marketing strategies with attraction factors important to nurses. This article presents the results of a survey of 666 nursing students graduating in the spring of 2009 in the Canadian province of Quebec. Hypotheses were tested using repeated-measures analysis of variance and post hoc tests. Consistent with hypotheses, the results showed that quality of care, type of work, compensation, and employer branding are organizational attraction factors that nursing graduates perceived as important, with quality of care being the most important one. These findings were later used by a Canadian university teaching hospital to optimize its employer branding and attraction strategy that resulted in an increase in the hiring of university-trained nurses. Further research is needed to examine organizational attractiveness for new nurses over time, across generations, and within various cultural contexts.

  16. Sexual conflict over parental investment in repeated bouts: negotiation reduces overall care.

    PubMed

    Lessells, C M; McNamara, John M

    2012-04-22

    Understanding the evolution of parental care is complicated by the occurrence of evolutionary conflicts of interest within the family, variation in the quality and state of family members, and repeated bouts of investment in a family of offspring. As a result, family members are expected to negotiate over care. We present a model for the resolution of sexual conflict in which parents negotiate over repeated bouts of care. Negotiation is mediated by parents deciding at the start of each bout how much care to give on the basis of the state (mass) of offspring, which reflects the amount of care previously received. The evolutionarily stable pattern of care depends on whether the parents care together for the whole family, or each cares alone for part of the divided family. When they care together, they provide less care in the first bout, more in the last bout, and less care overall, resulting in lower parental and offspring fitness. Our results emphasize that negotiation over parental care may occur as a means of avoiding exploitation owing to sexual conflict, even in the absence of variation in the quality of either sex of parent, and lead to a reduction in fitness.

  17. Repeated exposure to immobilization or two different footshock intensities reveals differential adaptation of the hypothalamic-pituitary-adrenal axis.

    PubMed

    Rabasa, Cristina; Muñoz-Abellán, Cristina; Daviu, Núria; Nadal, Roser; Armario, Antonio

    2011-05-03

    Factors involved in adaptation to repeated stress are not well-characterized. For instance, acute footshock (FS) of high intensity appears to be less severe than immobilization (IMO) in light of the speed of post-stress recovery of the hypothalamic-pituitary-adrenal (HPA) axis and other physiological variables. However, repeated exposure to IMO consistently resulted in reduction of the HPA response to the same stressor (adaptation), whereas failure to adapt has been usually reported after FS. Thus, in the present work we directly compared the activation of HPA axis and other physiological changes in response to both acute and repeated exposure to IMO and two intensities of FS (medium and high) in adult male rats. Control rats were exposed to the FS boxes but they did not receive shocks. Daily repeated exposure to IMO resulted in significant adaptation of the overall ACTH and corticosterone responses to the stressor. Such a reduction was also observed with repeated exposure to FS boxes and FS-medium, whereas repeated exposure to FS-high only resulted in a small reduction of the corticosterone response during the post-stress period. This suggests that some properties of FS-high make adaptation to it difficult. Interestingly, overall changes in food intake and body weight gain throughout the week of exposure to the stressors reveal a greater impact of IMO than FS-high, indicating that factors other than the intensity of a stressor, at least when evaluated in function of the above physiological variables, can influence HPA adaptation. Since FS exposure is likely to cause more pain than IMO, activation of nociceptive signals above a certain level may negatively affect HPA adaptation to repeated stressors. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Device-independent secret-key-rate analysis for quantum repeaters

    NASA Astrophysics Data System (ADS)

    Holz, Timo; Kampermann, Hermann; Bruß, Dagmar

    2018-01-01

    The device-independent approach to quantum key distribution (QKD) aims to establish a secret key between two or more parties with untrusted devices, potentially under full control of a quantum adversary. The performance of a QKD protocol can be quantified by the secret key rate, which can be lower bounded via the violation of an appropriate Bell inequality in a setup with untrusted devices. We study secret key rates in the device-independent scenario for different quantum repeater setups and compare them to their device-dependent analogon. The quantum repeater setups under consideration are the original protocol by Briegel et al. [Phys. Rev. Lett. 81, 5932 (1998), 10.1103/PhysRevLett.81.5932] and the hybrid quantum repeater protocol by van Loock et al. [Phys. Rev. Lett. 96, 240501 (2006), 10.1103/PhysRevLett.96.240501]. For a given repeater scheme and a given QKD protocol, the secret key rate depends on a variety of parameters, such as the gate quality or the detector efficiency. We systematically analyze the impact of these parameters and suggest optimized strategies.

  19. Geometric Positioning for Satellite Imagery without Ground Control Points by Exploiting Repeated Observation.

    PubMed

    Ma, Zhenling; Wu, Xiaoliang; Yan, Li; Xu, Zhenliang

    2017-01-26

    With the development of space technology and the performance of remote sensors, high-resolution satellites are continuously launched by countries around the world. Due to high efficiency, large coverage and not being limited by the spatial regulation, satellite imagery becomes one of the important means to acquire geospatial information. This paper explores geometric processing using satellite imagery without ground control points (GCPs). The outcome of spatial triangulation is introduced for geo-positioning as repeated observation. Results from combining block adjustment with non-oriented new images indicate the feasibility of geometric positioning with the repeated observation. GCPs are a must when high accuracy is demanded in conventional block adjustment; the accuracy of direct georeferencing with repeated observation without GCPs is superior to conventional forward intersection and even approximate to conventional block adjustment with GCPs. The conclusion is drawn that taking the existing oriented imagery as repeated observation enhances the effective utilization of previous spatial triangulation achievement, which makes the breakthrough for repeated observation to improve accuracy by increasing the base-height ratio and redundant observation. Georeferencing tests using data from multiple sensors and platforms with the repeated observation will be carried out in the follow-up research.

  20. The Effects of Repeated Writing and Repeated Revision Strategies on Composing Fluency of Learning Disabled Adolescents. Final Report.

    ERIC Educational Resources Information Center

    Harriman, Nancy E.; Gajar, Anna H.

    The study investigated the use of repeated writings as a means of increasing written language fluency with 48 learning disabled students in senior high school resource room English classes. Subjects received one of four treatments for 4 days: repeated writing with structural cues, repeated revision with structural cues, writing on a new topic with…

  1. Highly sensitive detection of individual HEAT and ARM repeats with HHpred and COACH.

    PubMed

    Kippert, Fred; Gerloff, Dietlind L

    2009-09-24

    HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high sensitivity at a low false positive rate and will therefore greatly enhance the accuracy of predictions of HEAT and ARM domains.

  2. Highly Sensitive Detection of Individual HEAT and ARM Repeats with HHpred and COACH

    PubMed Central

    Kippert, Fred; Gerloff, Dietlind L.

    2009-01-01

    Background HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Methodology and Principal Findings Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. Significance A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high sensitivity at a low false positive rate and will therefore greatly enhance the accuracy of predictions of HEAT and ARM domains. PMID:19777061

  3. Designing occupancy studies: general advice and allocating survey effort

    USGS Publications Warehouse

    MacKenzie, D.I.; Royle, J. Andrew

    2005-01-01

    1. The fraction of sampling units in a landscape where a target species is present (occupancy) is an extensively used concept in ecology. Yet in many applications the species will not always be detected in a sampling unit even when present, resulting in biased estimates of occupancy. Given that sampling units are surveyed repeatedly within a relatively short timeframe, a number of similar methods have now been developed to provide unbiased occupancy estimates. However, practical guidance on the efficient design of occupancy studies has been lacking. 2. In this paper we comment on a number of general issues related to designing occupancy studies, including the need for clear objectives that are explicitly linked to science or management, selection of sampling units, timing of repeat surveys and allocation of survey effort. Advice on the number of repeat surveys per sampling unit is considered in terms of the variance of the occupancy estimator, for three possible study designs. 3. We recommend that sampling units should be surveyed a minimum of three times when detection probability is high (> 0.5 survey-1), unless a removal design is used. 4. We found that an optimal removal design will generally be the most efficient, but we suggest it may be less robust to assumption violations than a standard design. 5. Our results suggest that for a rare species it is more efficient to survey more sampling units less intensively, while for a common species fewer sampling units should be surveyed more intensively. 6. Synthesis and applications. Reliable inferences can only result from quality data. To make the best use of logistical resources, study objectives must be clearly defined; sampling units must be selected, and repeated surveys timed appropriately; and a sufficient number of repeated surveys must be conducted. Failure to do so may compromise the integrity of the study. The guidance given here on study design issues is particularly applicable to studies of species occurrence and distribution, habitat selection and modelling, metapopulation studies and monitoring programmes.

  4. Development of a Gene-Centered SSR Atlas as a Resource for Papaya (Carica papaya) Marker-Assisted Selection and Population Genetic Studies

    PubMed Central

    Vidal, Newton Medeiros; Grazziotin, Ana Laura; Ramos, Helaine Christine Cancela; Pereira, Messias Gonzaga; Venancio, Thiago Motta

    2014-01-01

    Carica papaya (papaya) is an economically important tropical fruit. Molecular marker-assisted selection is an inexpensive and reliable tool that has been widely used to improve fruit quality traits and resistance against diseases. In the present study we report the development and validation of an atlas of papaya simple sequence repeat (SSR) markers. We integrated gene predictions and functional annotations to provide a gene-centered perspective for marker-assisted selection studies. Our atlas comprises 160,318 SSRs, from which 21,231 were located in genic regions (i.e. inside exons, exon-intron junctions or introns). A total of 116,453 (72.6%) of all identified repeats were successfully mapped to one of the nine papaya linkage groups. Primer pairs were designed for markers from 9,594 genes (34.5% of the papaya gene complement). Using papaya-tomato orthology assessments, we assembled a list of 300 genes (comprising 785 SSRs) potentially involved in fruit ripening. We validated our atlas by screening 73 SSR markers (including 25 fruit ripening genes), achieving 100% amplification rate and uncovering 26% polymorphism rate between the parental genotypes (Sekati and JS12). The SSR atlas presented here is the first comprehensive gene-centered collection of annotated and genome positioned papaya SSRs. These features combined with thousands of high-quality primer pairs make the atlas an important resource for the papaya research community. PMID:25393538

  5. The effect of horticultural therapy on the quality of life of palliative care patients.

    PubMed

    Lai, Claudia Kam-Yuk; Lau, Carmen Ka-Yan; Kan, Wai Yin; Lam, Wai Man; Fung, Connie Yuen Yee

    2017-01-01

    Palliative care patients experience a variety of needs and perceive their quality of life as being only fair. This study adopted a single-group repeated-measure design to investigate the effect of horticultural therapy on the quality of life of palliative care patients using the Quality of Life Concern in End of Life Questionnaire. Significant differences in the domains of "existential distress" and "health care concern" were observed immediately postintervention and at 4 weeks postintervention, respectively. No other significant differences were seen in the other domains or in the total mean score of the outcome measure.

  6. Two Low Coverage Bird Genomes and a Comparison of Reference-Guided versus De Novo Genome Assemblies

    PubMed Central

    Card, Daren C.; Schield, Drew R.; Reyes-Velasco, Jacobo; Fujita, Matthew K.; Andrew, Audra L.; Oyler-McCance, Sara J.; Fike, Jennifer A.; Tomback, Diana F.; Ruggiero, Robert P.; Castoe, Todd A.

    2014-01-01

    As a greater number and diversity of high-quality vertebrate reference genomes become available, it is increasingly feasible to use these references to guide new draft assemblies for related species. Reference-guided assembly approaches may substantially increase the contiguity and completeness of a new genome using only low levels of genome coverage that might otherwise be insufficient for de novo genome assembly. We used low-coverage (∼3.5–5.5x) Illumina paired-end sequencing to assemble draft genomes of two bird species (the Gunnison Sage-Grouse, Centrocercus minimus, and the Clark's Nutcracker, Nucifraga columbiana). We used these data to estimate de novo genome assemblies and reference-guided assemblies, and compared the information content and completeness of these assemblies by comparing CEGMA gene set representation, repeat element content, simple sequence repeat content, and GC isochore structure among assemblies. Our results demonstrate that even lower-coverage genome sequencing projects are capable of producing informative and useful genomic resources, particularly through the use of reference-guided assemblies. PMID:25192061

  7. Estimation of genetic parameters related to eggshell strength using random regression models.

    PubMed

    Guo, J; Ma, M; Qu, L; Shen, M; Dou, T; Wang, K

    2015-01-01

    This study examined the changes in eggshell strength and the genetic parameters related to this trait throughout a hen's laying life using random regression. The data were collected from a crossbred population between 2011 and 2014, where the eggshell strength was determined repeatedly for 2260 hens. Using random regression models (RRMs), several Legendre polynomials were employed to estimate the fixed, direct genetic and permanent environment effects. The residual effects were treated as independently distributed with heterogeneous variance for each test week. The direct genetic variance was included with second-order Legendre polynomials and the permanent environment with third-order Legendre polynomials. The heritability of eggshell strength ranged from 0.26 to 0.43, the repeatability ranged between 0.47 and 0.69, and the estimated genetic correlations between test weeks was high at > 0.67. The first eigenvalue of the genetic covariance matrix accounted for about 97% of the sum of all the eigenvalues. The flexibility and statistical power of RRM suggest that this model could be an effective method to improve eggshell quality and to reduce losses due to cracked eggs in a breeding plan.

  8. PopAffiliator: online calculator for individual affiliation to a major population group based on 17 autosomal short tandem repeat genotype profile.

    PubMed

    Pereira, Luísa; Alshamali, Farida; Andreassen, Rune; Ballard, Ruth; Chantratita, Wasun; Cho, Nam Soo; Coudray, Clotilde; Dugoujon, Jean-Michel; Espinoza, Marta; González-Andrade, Fabricio; Hadi, Sibte; Immel, Uta-Dorothee; Marian, Catalin; Gonzalez-Martin, Antonio; Mertens, Gerhard; Parson, Walther; Perone, Carlos; Prieto, Lourdes; Takeshita, Haruo; Rangel Villalobos, Héctor; Zeng, Zhaoshu; Zhivotovsky, Lev; Camacho, Rui; Fonseca, Nuno A

    2011-09-01

    Because of their sensitivity and high level of discrimination, short tandem repeat (STR) maker systems are currently the method of choice in routine forensic casework and data banking, usually in multiplexes up to 15-17 loci. Constraints related to sample amount and quality, frequently encountered in forensic casework, will not allow to change this picture in the near future, notwithstanding the technological developments. In this study, we present a free online calculator named PopAffiliator ( http://cracs.fc.up.pt/popaffiliator ) for individual population affiliation in the three main population groups, Eurasian, East Asian and sub-Saharan African, based on genotype profiles for the common set of STRs used in forensics. This calculator performs affiliation based on a model constructed using machine learning techniques. The model was constructed using a data set of approximately fifteen thousand individuals collected for this work. The accuracy of individual population affiliation is approximately 86%, showing that the common set of STRs routinely used in forensics provide a considerable amount of information for population assignment, in addition to being excellent for individual identification.

  9. The development and validation of the Bronchiectasis Health Questionnaire.

    PubMed

    Spinou, Arietta; Siegert, Richard J; Guan, Wei-Jie; Patel, Amit S; Gosker, Harry R; Lee, Kai K; Elston, Caroline; Loebinger, Michael R; Wilson, Robert; Garrod, Rachel; Birring, Surinder S

    2017-05-01

    Health-related quality of life or health status is significantly impaired in bronchiectasis. There is a paucity of brief, simple-to-use, disease-specific health status measures. The aim of this study was to develop and validate the Bronchiectasis Health Questionnaire (BHQ), a new health status measure that is brief and generates a single overall score.Patients with bronchiectasis were recruited from two outpatient clinics, during a clinically stable stage. The development of the questionnaire followed three phases: item generation and item reduction using Rasch analysis, validation, and repeatability testing. The BHQ was translated into 11 languages using standardised methodology.206 patients with bronchiectasis completed a preliminary 65-item questionnaire. 55 items were removed due to redundancy or poor fit to the Rasch model. The final version of the BHQ consisted of 10 items. Internal consistency was good (Cronbach's α=0.85). Convergent validity of the BHQ with the St George's Respiratory Questionnaire was high (r= -0.82; p<0.001) and moderate with lung function (forced expiratory volume in 1 s % predicted r= -0.27; p=0.001). There was a significant association between BHQ scores and number of exacerbations of bronchiectasis in the last 12 months (p<0.001), hospital admissions (p=0.001) and computed tomography scan bronchiectasis pulmonary lobe counts (p<0.001). BHQ scores were significantly worse in patients with sputum bacterial colonisation versus no colonisation (p=0.048). The BHQ was highly repeatable after 2 weeks (intraclass correlation coefficient 0.89).The BHQ is a brief, valid and repeatable, self-completed health status questionnaire for bronchiectasis that generates a single total score. It can be used in the clinic to assess bronchiectasis from the patient's perspective. Copyright ©ERS 2017.

  10. Effect of computerized cognitive behavioral therapy on acquisition of coping skills among cocaine-dependent individuals enrolled in methadone maintenance.

    PubMed

    Kiluk, Brian D; DeVito, Elise E; Buck, Matthew B; Hunkele, Karen; Nich, Charla; Carroll, Kathleen M

    2017-11-01

    The acquisition of coping skills has long been considered one of the putative mechanisms of cognitive behavioral therapy (CBT) for substance use disorders, yet consistent statistical support is lacking. This study sought to replicate and extend prior findings regarding the quality of coping skills as a mediator of abstinence outcomes from a computerized CBT program for substance users. Participants were methadone-maintained, cocaine dependent individuals enrolled in a clinical trial evaluating the efficacy of computer-based training for CBT ('CBT4CBT') as an add-on to treatment as usual (TAU+CBT4CBT) compared to TAU only. A subsample (N=71) completed a role play assessment to measure coping skills, the Drug Risk Response Test (DRRT), which was administered before, during (week 4), and after the 8-week treatment period. Participants' verbal responses to various high-risk situations for cocaine use were recorded and independent evaluators rated the quality of the coping responses. Results of repeated measures analyses revealed a main effect of time for the quality of overall responses [F(1, 141.26)=4.29, p<0.01], indicating improvement in the quality of coping skills across groups, yet no differential effect of treatment. Despite the significant association between coping responses and abstinence outcomes, analyses did not support the quality of coping skills as a mediator of treatment effects. However, among the high-risk situations wherein individuals provided lower quality responses at baseline, those assigned to TAU+CBT4CBT showed greater improvement compared to those assigned to TAU only [F(1, 697.65)=6.47, p=0.01]. This study failed to replicate the quality of coping skills as a mediator of CBT4CBT's effect on reducing drug use previously shown in a mixed outpatient substance use sample. However, in this methadone maintained sample, those with poorer quality skills in response to certain high-risk situations at baseline appeared to improve their coping strategies following CBT4CBT compared to standard methadone treatment alone. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Automating PACS quality control with the Vanderbilt image processing enterprise resource

    NASA Astrophysics Data System (ADS)

    Esparza, Michael L.; Welch, E. Brian; Landman, Bennett A.

    2012-02-01

    Precise image acquisition is an integral part of modern patient care and medical imaging research. Periodic quality control using standardized protocols and phantoms ensures that scanners are operating according to specifications, yet such procedures do not ensure that individual datasets are free from corruption; for example due to patient motion, transient interference, or physiological variability. If unacceptable artifacts are noticed during scanning, a technologist can repeat a procedure. Yet, substantial delays may be incurred if a problematic scan is not noticed until a radiologist reads the scans or an automated algorithm fails. Given scores of slices in typical three-dimensional scans and widevariety of potential use cases, a technologist cannot practically be expected inspect all images. In large-scale research, automated pipeline systems have had great success in achieving high throughput. However, clinical and institutional workflows are largely based on DICOM and PACS technologies; these systems are not readily compatible with research systems due to security and privacy restrictions. Hence, quantitative quality control has been relegated to individual investigators and too often neglected. Herein, we propose a scalable system, the Vanderbilt Image Processing Enterprise Resource (VIPER) to integrate modular quality control and image analysis routines with a standard PACS configuration. This server unifies image processing routines across an institutional level and provides a simple interface so that investigators can collaborate to deploy new analysis technologies. VIPER integrates with high performance computing environments has successfully analyzed all standard scans from our institutional research center over the course of the last 18 months.

  12. High-Intensity Small-Sided Games versus Repeated Sprint Training in Junior Soccer Players.

    PubMed

    Eniseler, Niyazi; Şahan, Çağatay; Özcan, Ilker; Dinler, Kıvanç

    2017-12-01

    The aim of this study was to compare the effects of high-intensity small-sided games training (SSGT) versus repeated-sprint training (RST) on repeated-sprint ability (RSA), soccer specific endurance performance and short passing ability among junior soccer players. The junior soccer players were recruited from of a professional team (age 16.9 ± 1.1 years). The tests included the repeated-shuttle-sprint ability test (RSSAT), Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and Loughborough Soccer Passing Test (LSPT). Nineteen participants were randomly assigned to either the small-sided games training (SSGTG) (n = 10) or repeated-sprint training group (RSTG) (n = 9). Small-sided games or repeated-sprint training were added to the regular training sessions for two days of the regular practice week. The Wilcoxon signed-rank and Mann-Whitney U tests were used to examine differences in groups and training effects. A time x training group effect was found in the improvement of short-passing ability for the smallsided games training group which showed significantly better scores than the repeated-sprint training group (p ≤ 0.05). Both groups showed similar improvements in RSAdecrement (p < 0.05). Only the repeated-sprint training group improved in the Yo-Yo IR1 (p < 0.05). This study clearly shows that high-intensity small-sided games training can be used as an effective training mode to enhance both repeated sprint ability and short-passing ability.

  13. High-Intensity Small-Sided Games versus Repeated Sprint Training in Junior Soccer Players

    PubMed Central

    Şahan, Çağatay; Özcan, Ilker; Dinler, Kıvanç

    2017-01-01

    Abstract The aim of this study was to compare the effects of high-intensity small-sided games training (SSGT) versus repeated-sprint training (RST) on repeated-sprint ability (RSA), soccer specific endurance performance and short passing ability among junior soccer players. The junior soccer players were recruited from of a professional team (age 16.9 ± 1.1 years). The tests included the repeated-shuttle-sprint ability test (RSSAT), Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and Loughborough Soccer Passing Test (LSPT). Nineteen participants were randomly assigned to either the small-sided games training (SSGTG) (n = 10) or repeated-sprint training group (RSTG) (n = 9). Small-sided games or repeated-sprint training were added to the regular training sessions for two days of the regular practice week. The Wilcoxon signed-rank and Mann-Whitney U tests were used to examine differences in groups and training effects. A time x training group effect was found in the improvement of short-passing ability for the smallsided games training group which showed significantly better scores than the repeated-sprint training group (p ≤ 0.05). Both groups showed similar improvements in RSAdecrement (p < 0.05). Only the repeated-sprint training group improved in the Yo-Yo IR1 (p < 0.05). This study clearly shows that high-intensity small-sided games training can be used as an effective training mode to enhance both repeated sprint ability and short-passing ability. PMID:29339990

  14. The Development of Quality Measures for the Performance and Interpretation of Esophageal Manometry

    PubMed Central

    Yadlapati, Rena; Gawron, Andrew J.; Keswani, Rajesh N.; Bilimoria, Karl; Castell, Donald O.; Dunbar, Kerry B.; Gyawali, Chandra P.; Jobe, Blair A.; Katz, Philip O.; Katzka, David A.; Lacy, Brian E.; Massey, Benson T.; Richter, Joel E.; Schnoll-Sussman, Felice; Spechler, Stuart J.; Tatum, Roger; Vela, Marcelo F.; Pandolfino, John E.

    2016-01-01

    Background and Aims Esophageal manometry (EM) is the gold standard for the diagnosis of esophageal motility disorders. Variations in the performance and interpretation of EM result in discrepant diagnoses and unnecessary repeated procedures, and may negatively impact patient outcomes. A method to benchmark the procedural quality of EM is needed. The primary aim of this study was to develop quality measures for performing and interpreting EM. Methods The RAND/University of California, Los Angeles Appropriateness Methodology (RAM) was utilized. Fifteen experts in esophageal manometry were invited to be a part of the panel. Potential quality measures were identified through a literature search and interviews with experts. The expert panel ranked the proposed quality measures for appropriateness via a two-round process on the basis of RAM. Results Fourteen experts participated in all processes. A total of 29 measures were considered; 17 of these measures were ranked as appropriate and related to competency (2), pre-procedure (2), procedure (3) and interpretation (10). The latter 10 were integrated into a single composite measure. Thus, 8 final measures were determined to be appropriate quality measures for EM. Five strong recommendations were also endorsed by the experts, however they were not ranked as appropriate quality measures. Conclusions Eight formally validated quality measures for the performance and interpretation of EM were developed on the basis of RAM. These measures represent key aspects of a high-quality EM study and should be uniformly adopted. Evaluation of these measures in clinical practice is needed to assess their impact on outcomes. PMID:26499925

  15. Exposing the Science in Citizen Science: Fitness to Purpose and Intentional Design.

    PubMed

    Parrish, Julia K; Burgess, Hillary; Weltzin, Jake F; Fortson, Lucy; Wiggins, Andrea; Simmons, Brooke

    2018-05-21

    Citizen science is a growing phenomenon. With millions of people involved and billions of in-kind dollars contributed annually, this broad extent, fine grain approach to data collection should be garnering enthusiastic support in the mainstream science and higher education communities. However, many academic researchers demonstrate distinct biases against the use of citizen science as a source of rigorous information. To engage the public in scientific research, and the research community in the practice of citizen science, a mutual understanding is needed of accepted quality standards in science, and the corresponding specifics of project design and implementation when working with a broad public base. We define a science-based typology focused on the degree to which projects deliver the type(s) and quality of data/work needed to produce valid scientific outcomes directly useful in science and natural resource management. Where project intent includes direct contribution to science and the public is actively involved either virtually or hands-on, we examine the measures of quality assurance (methods to increase data quality during the design and implementation phases of a project) and quality control (post hoc methods to increase the quality of scientific outcomes). We suggest that high quality science can be produced with massive, largely one-off, participation if data collection is simple and quality control includes algorithm voting, statistical pruning and/or computational modeling. Small to mid-scale projects engaging participants in repeated, often complex, sampling can advance quality through expert-led training and well-designed materials, and through independent verification. Both approaches - simplification at scale and complexity with care - generate more robust science outcomes.

  16. A ranking index for quality assessment of forensic DNA profiles forensic DNA profiles

    PubMed Central

    2010-01-01

    Background Assessment of DNA profile quality is vital in forensic DNA analysis, both in order to determine the evidentiary value of DNA results and to compare the performance of different DNA analysis protocols. Generally the quality assessment is performed through manual examination of the DNA profiles based on empirical knowledge, or by comparing the intensities (allelic peak heights) of the capillary electrophoresis electropherograms. Results We recently developed a ranking index for unbiased and quantitative quality assessment of forensic DNA profiles, the forensic DNA profile index (FI) (Hedman et al. Improved forensic DNA analysis through the use of alternative DNA polymerases and statistical modeling of DNA profiles, Biotechniques 47 (2009) 951-958). FI uses electropherogram data to combine the intensities of the allelic peaks with the balances within and between loci, using Principal Components Analysis. Here we present the construction of FI. We explain the mathematical and statistical methodologies used and present details about the applied data reduction method. Thereby we show how to adapt the ranking index for any Short Tandem Repeat-based forensic DNA typing system through validation against a manual grading scale and calibration against a specific set of DNA profiles. Conclusions The developed tool provides unbiased quality assessment of forensic DNA profiles. It can be applied for any DNA profiling system based on Short Tandem Repeat markers. Apart from crime related DNA analysis, FI can therefore be used as a quality tool in paternal or familial testing as well as in disaster victim identification. PMID:21062433

  17. Development of highly-ordered, ferroelectric inverse opal films using sol gel infiltration

    NASA Astrophysics Data System (ADS)

    Matsuura, N.; Yang, S.; Sun, P.; Ruda, H. E.

    2005-07-01

    Highly-ordered, ferroelectric, Pb-doped Ba0.7Sr0.3TiO3, inverse opal films were fabricated by spin-coating a sol gel precursor into a polystyrene artificial opal template followed by heat treatment. Thin films of the ferroelectric were independently studied and were shown to exhibit good dielectric properties and high refractive indices. The excellent quality of the final inverse opal film using this spin-coating infiltration method was confirmed by scanning electron microscopy images and the good correspondence between optical reflection data and theoretical simulations. Using this method, the structural and material parameters of the final ferroelectric inverse opal film were easily adjusted by template heating and through repeated infiltrations, without changes in the initial template or precursor. Also, crack-free inverse opal thin films were fabricated over areas comparable to that of the initial crack-free polystyrene template (˜100 by 100 μm2).

  18. SU-E-J-26: Analysis of Image Quality in CBCT QA Using a Treatment Planning System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, M

    2014-06-01

    Purpose: The objective of this study is to propose an alternative QA technique that analyzes imaging quality(IQ) in CBCT-QA processing. Methods: A catphan phantom was used to take CT imaging data set that were imported into a treatment planning system - Eclipse. The image quality was analyzed in terms of in-slice geometry resolution, Hounsfield numbers(HU) accuracy, mean-slice thickness, edge-to-center uniformity, low contrast resolution, and high contrast spatial resolution in Eclipse workstation. The CBCT-QA was also analyzed by OBI-workstation and a commercial software. Comparison was made to evaluation feasibility in a TPS environment. Results: The analysis of IQ was conducted inmore » Eclipse v10.0 TPS. In-slice geometric resolution was measured between 2-rods in section CTP404 and repeated for all 4 rods with the difference between expected and measured values less than +/−0.1 cm. For HU, the difference between expected and measured values in HU was found much less than +/−40. Mean slice thickness measured by a distance on the wire proportional to scanner increment multiplying by a factor of 0.42. After repeating measurements to 4 wires, the average difference between expected and measured values was less +/−0.124 mm in slice thickness. HU uniformity was measured in section CTP486 with the tolerance less than +/−40 HU. Low contrast resolution in section CTP515 and high contrast resolution in section CTP528 were found to be 7 disks in diameter of 4 mm and 6 lp/cm, respectively. Eclipse TPS results indicated a good agreement to those obtained in OBI workstation and ImagePro software for major parameters. Conclusion: An analysis of IQ was proposed as an alternative CBCT QA processing. Based upon measured data assessment, proposed method was accurate and consistent to IQ evaluation and TG142 guideline. The approach was to utilize TPS resource, which can be valuable to re-planning, verification, and delivery in adaptive therapy.« less

  19. Leadership quality: a factor important for social capital in healthcare organizations.

    PubMed

    Strömgren, Marcus; Eriksson, Andrea; Ahlstrom, Linda; Bergman, David Kristofer; Dellve, Lotta

    2017-04-10

    Purpose The purpose of this paper is to investigate the relation between leadership and social capital and what qualities of leadership are important for social capital among employees in hospital settings over time. Design/methodology/approach A cohort of employees in hospitals answered a questionnaire at three occasions. Five small (approx. 100-bed) or mid-sized (approx. 500-bed) hospitals were included. The response rate was 54 percent at baseline ( n=865), 59 percent at one-year follow-up ( n=908) and 67 percent at two-year follow-up ( n=632). Findings Repeated measures over time showed differences between groups in levels of social capital with respect to levels of leadership quality. Relation-oriented leadership had the strongest association with social capital. There was evidence that leadership was associated with social capital over time and that different kinds of leadership qualities were associated with social capital. Research limitations/implications This study conducted and analyzed quantitative data, and therefore, there is no knowledge of managers' or employees' own perceptions in this study. However, it would be interesting to compare managers' decreased and increased leadership quality and how such differences affect social capital over time. Practical implications The findings feature the possibility for healthcare leaders to build high quality leadership as an important resource for social capital, by using different leadership orientations under different circumstances. Originality/value The paper showed that leadership was an important factor for building social capital and that different leadership qualities have different importance with respect to certain circumstances.

  20. A re-evaluation of the taste and odour of methyl tertiary butyl ether (MTBE) in drinking water.

    PubMed

    Suffet, I H

    2007-01-01

    Methyl tertiary butyl ether (MTBE) is a gasoline additive that has been found in groundwater when an underground gasoline storage tank leaks. Although dependent on the clean-up standards that are applied, clean-up costs have been estimated in the US alone to be in the billions of dollars. MTBE is considered primarily a taste and odour concern and not a toxicity issue at concentrations found in drinking water. Thus, the clean-up of MTBE problems is controlled by the MTBE odour threshold concentration (OTC). The level of clean-up and associated differential of millions of dollars is a matter of concern for water purveyors and well owners. A 1993 study of nine OTC studies showed the OTC of MTBE in water to be between 0.04 and 0.06 microg/L, a level over two orders of magnitude less than eight other studies. This 1993 study was repeated at the original laboratory in 2004 and is reported in this paper. The laboratory's quality control programme and ability to repeat one of the eight other studies indicated the laboratory was qualified to repeat its original OTC study. The flavour and odour detection threshold range in the 1993 study, however, could not be confirmed by trained assessors repeating the original study in 2004. The inconsistencies in the data and the high detection on water blanks indicate that the dilution series of the test solutions for the 1993 study were mainly at subthreshold levels. Therefore, the original study of 1993 is not a valid OTC study for MTBE and should not be used to develop drinking water and clean-up standards. The OTC of MTBE is over 15 microg/L for the eight valid studies.

  1. The rate of repeating X-rays in the medical centers of Jenin District/Palestine and how to reduce patient exposure to radiation

    NASA Astrophysics Data System (ADS)

    Assi, Abed Al Nasser

    2018-03-01

    Reduction of the patient's received radiation dose to as low as reasonably achievable (ALARA) is based on recommendations of radiation protection organizations such as the International Commission on Radiological Protection (ICRP) and the National Radiological Protection Board (NRPB). The aim of this study was to explore the frequency and characteristics of rejected / repeated radiographic films in governmental and private centers in Jenin city. The radiological centers were chosen based on their high volume of radiographic studies. The evaluation was carried out over a period of four months. The collected data were compiled at the end of each week and entered into a computer for analysis at the end of study. Overall 5000 films (images) were performed in four months, The average repeat rate of radiographic images was 10% (500 films). Repetition rate was the same for both thoracic and abdominal images (42%). The main reason for repeating imaging was inadequate imaging quality (58.2%) and poor film processing (38%). Human error was the most likely reason necessitating the repetition of the radiographs (48 %). Infant and children groups comprised 85% of the patient population that required repetition of the radiographic studies. In conclusion, we have a higher repetition rate of imaging studies compared to the international standards (10% vs. 4-6%, respectively). This is especially noticeable in infants and children, and mainly attributed to human error in obtaining and processing images. This is an important issue that needs to be addressed on a national level due to the ill effects associated with excessive exposure to radiation especially in children, and to reduce cost of the care delivered.

  2. Chlamydia screening is not cost-effective at low participation rates: evidence from a repeated register-based implementation study in The Netherlands.

    PubMed

    de Wit, G Ardine; Over, Eelco A B; Schmid, Boris V; van Bergen, Jan E A M; van den Broek, Ingrid V F; van der Sande, Marianne A B; Welte, Robert; Op de Coul, Eline L M; Kretzschmar, Mirjam E

    2015-09-01

    In three pilot regions of The Netherlands, all 16-29 year olds were invited to participate in three annual rounds of Chlamydia screening. The aim of the present study is to evaluate the cost-effectiveness of repeated Chlamydia screening, based on empirical data. A mathematical model was employed to estimate the influence of repeated screening on prevalence and incidence of Chlamydial infection. A model simulating the natural history of Chlamydia was combined with cost and utility data to estimate the number of major outcomes and quality-adjusted life-years (QALYs) associated with Chlamydia. Six screening scenarios (16-29 years annually; 16-24 years annually; women only; biennial screening; biennial screening women only; screening every five years) were compared with no screening in two sexual networks, representing both lower ('national network') and higher ('urban network') baseline prevalence. Incremental cost-effectiveness ratios (ICERs) for the different screening scenarios were estimated. Uncertainty and sensitivity analyses were performed. In all scenarios and networks, cost per major outcome averted are above €5000. Cost per QALY are at least €50,000. The default scenario as piloted in the Netherlands was least cost-effective, with ICERs of €232,000 in the national and €145,000 in the urban sexual network. Results were robust in sensitivity analyses. It is unlikely that repeated rounds of Chlamydia screening will be cost-effective. Only at high levels of willingness to pay for a QALY (>€50,000) screening may be more cost-effective than no screening. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Molecular characterization and physical localization of highly repetitive DNA sequences from Brazilian Alstroemeria species.

    PubMed

    Kuipers, A G J; Kamstra, S A; de Jeu, M J; Visser, R G F

    2002-01-01

    Highly repetitive DNA sequences were isolated from genomic DNA libraries of Alstroemeria psittacina and A. inodora. Among the repetitive sequences that were isolated, tandem repeats as well as dispersed repeats could be discerned. The tandem repeats belonged to a family of interlinked Sau3A subfragments with sizes varying from 68-127 bp, and constituted a larger HinfI repeat of approximately 400 bp. Southern hybridization showed a similar molecular organization of the tandem repeats in each of the Brazilian Alstroemeria species tested. None of the repeats hybridized with DNA from Chilean Alstroemeria species, which indicates that they are specific for the Brazilian species. In-situ localization studies revealed the tandem repeats to be localized in clusters on the chromosomes of A. inodora and A. psittacina: distal hybridization sites were found on chromosome arms 2PS, 6PL, 7PS, 7PL and 8PL, interstitial sites on chromosome arms 2PL, 3PL, 4PL and 5PL. The applicability of the tandem repeats for cytogenetic analysis of interspecific hybrids and their role in heterochromatin organization are discussed.

  4. Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention.

    PubMed

    Seyedmehdi, Seyed Mohammad; Attarchi, Mirsaeed; Yazdanparast, Taraneh; Lakeh, Maziar Moradi

    2013-03-01

    Quality improvement, standardisation of spirometry testing, and interpretation of results are critically important in the occupational setting. To determine the quality of spirometry tests and pulmonary function changes in two consecutive years among the personnel of an industrial company. This study was performed in an oil refinery in Iran in 2011. Data on 1,004 male personnel were evaluated before and after a training course conducted according to the National Institute for Occupational Safety and Health guidelines. American Thoracic Society/European Respiratory Society guidelines were used for assessment of the acceptability and repeatability criteria. The most common error in the first year of evaluation was forced vital capacity >6 seconds or a 1 second plateau. Acceptability and proper interpretation significantly improved after the course (p<0.05), but repeatability did not change significantly (p>0.05). The results of this study show that the validity and quality of spirometric tests conducted in the studied company in Iran were unacceptable, but these improved significantly after the training intervention. The study demonstrated the lack of a systematic guideline for conducting spirometry and interpreting the results in the occupational setting in Iran, and emphasises the need for a nationwide programme to improve the quality of spirometry tests in this setting.

  5. Systematic ultrasound-guided saturation and template biopsy of the prostate: indications and advantages of extended sampling.

    PubMed

    Isbarn, Hendrik; Briganti, Alberto; De Visschere, Pieter J L; Fütterer, Jurgen J; Ghadjar, Pirus; Giannarini, Gianluca; Ost, Piet; Ploussard, Guillaume; Sooriakumaran, Prasanna; Surcel, Christian I; van Oort, Inge M; Yossepowitch, Ofer; van den Bergh, Roderick C N

    2015-04-01

    Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. A non-systematic review of the literature was performed from 2000 through 2013. Studies of highest evidence (randomized controlled trials, prospective non-randomized studies, and retrospective reports of high quality) comparing standard vs saturation schemes on initial and repeat PB were evaluated. Outcome measures were overall PCa detection rate, detection rate of insignificant PCa, and procedure-associated morbidity. On initial PB, there is growing evidence that a saturation scheme is associated with a higher PCa detection rate compared to a standard one in men with lower PSA levels (<10 ng/ml), larger prostates (>40 cc), or lower PSA density values (<0.25 ng/ml/cc). However, these cut-offs are not uniform and differ among studies. Detection rates of insignificant PCa do not differ in a significant fashion between standard and saturation biopsies. On repeat PB, PCa detection rate is likewise higher with saturation protocols. Estimates of insignificant PCa vary widely due to differing definitions of insignificant disease. However, the rates of insignificant PCa appear to be comparable for the schemes in patients with only one prior negative biopsy, while saturation biopsy seems to detect more cases of insignificant PCa compared to standard biopsy in men with two or more prior negative biopsies. Very extensive sampling is associated with a high rate of acute urinary retention, whereas other severe adverse events, such as sepsis, appear not to occur more frequently with saturation schemes. Current evidence suggests that saturation schemes are associated with a higher PCa detection rate compared to standard ones on initial PB in men with lower PSA levels or larger prostates, and on repeat PB. Since most data are derived from retrospective studies, other endpoints such as detection rate of insignificant disease - especially on repeat PB - show broad variations throughout the literature and must, thus, be interpreted with caution. Future prospective controlled trials should be conducted to compare extended templates with newer techniques, such as image-guided sampling, in order to optimize PCa diagnostic strategy.

  6. Construction and sequence sampling of deep-coverage, large-insert BAC libraries for three model lepidopteran species

    PubMed Central

    Wu, Chengcang; Proestou, Dina; Carter, Dorothy; Nicholson, Erica; Santos, Filippe; Zhao, Shaying; Zhang, Hong-Bin; Goldsmith, Marian R

    2009-01-01

    Background Manduca sexta, Heliothis virescens, and Heliconius erato represent three widely-used insect model species for genomic and fundamental studies in Lepidoptera. Large-insert BAC libraries of these insects are critical resources for many molecular studies, including physical mapping and genome sequencing, but not available to date. Results We report the construction and characterization of six large-insert BAC libraries for the three species and sampling sequence analysis of the genomes. The six BAC libraries were constructed with two restriction enzymes, two libraries for each species, and each has an average clone insert size ranging from 152–175 kb. We estimated that the genome coverage of each library ranged from 6–9 ×, with the two combined libraries of each species being equivalent to 13.0–16.3 × haploid genomes. The genome coverage, quality and utility of the libraries were further confirmed by library screening using 6~8 putative single-copy probes. To provide a first glimpse into these genomes, we sequenced and analyzed the BAC ends of ~200 clones randomly selected from the libraries of each species. The data revealed that the genomes are AT-rich, contain relatively small fractions of repeat elements with a majority belonging to the category of low complexity repeats, and are more abundant in retro-elements than DNA transposons. Among the species, the H. erato genome is somewhat more abundant in repeat elements and simple repeats than those of M. sexta and H. virescens. The BLAST analysis of the BAC end sequences suggested that the evolution of the three genomes is widely varied, with the genome of H. virescens being the most conserved as a typical lepidopteran, whereas both genomes of H. erato and M. sexta appear to have evolved significantly, resulting in a higher level of species- or evolutionary lineage-specific sequences. Conclusion The high-quality and large-insert BAC libraries of the insects, together with the identified BACs containing genes of interest, provide valuable information, resources and tools for comprehensive understanding and studies of the insect genomes and for addressing many fundamental questions in Lepidoptera. The sample of the genomic sequences provides the first insight into the constitution and evolution of the insect genomes. PMID:19558662

  7. An Insertable Passive LC Pressure Sensor Based on an Alumina Ceramic for In Situ Pressure Sensing in High-Temperature Environments.

    PubMed

    Xiong, Jijun; Li, Chen; Jia, Pinggang; Chen, Xiaoyong; Zhang, Wendong; Liu, Jun; Xue, Chenyang; Tan, Qiulin

    2015-08-31

    Pressure measurements in high-temperature applications, including compressors, turbines, and others, have become increasingly critical. This paper proposes an implantable passive LC pressure sensor based on an alumina ceramic material for in situ pressure sensing in high-temperature environments. The inductance and capacitance elements of the sensor were designed independently and separated by a thermally insulating material, which is conducive to reducing the influence of the temperature on the inductance element and improving the quality factor of the sensor. In addition, the sensor was fabricated using thick film integrated technology from high-temperature materials that ensure stable operation of the sensor in high-temperature environments. Experimental results showed that the sensor accurately monitored pressures from 0 bar to 2 bar at temperatures up to 800 °C. The sensitivity, linearity, repeatability error, and hysteretic error of the sensor were 0.225 MHz/bar, 95.3%, 5.5%, and 6.2%, respectively.

  8. An Insertable Passive LC Pressure Sensor Based on an Alumina Ceramic for In Situ Pressure Sensing in High-Temperature Environments

    PubMed Central

    Xiong, Jijun; Li, Chen; Jia, Pinggang; Chen, Xiaoyong; Zhang, Wendong; Liu, Jun; Xue, Chenyang; Tan, Qiulin

    2015-01-01

    Pressure measurements in high-temperature applications, including compressors, turbines, and others, have become increasingly critical. This paper proposes an implantable passive LC pressure sensor based on an alumina ceramic material for in situ pressure sensing in high-temperature environments. The inductance and capacitance elements of the sensor were designed independently and separated by a thermally insulating material, which is conducive to reducing the influence of the temperature on the inductance element and improving the quality factor of the sensor. In addition, the sensor was fabricated using thick film integrated technology from high-temperature materials that ensure stable operation of the sensor in high-temperature environments. Experimental results showed that the sensor accurately monitored pressures from 0 bar to 2 bar at temperatures up to 800 °C. The sensitivity, linearity, repeatability error, and hysteretic error of the sensor were 0.225 MHz/bar, 95.3%, 5.5%, and 6.2%, respectively. PMID:26334279

  9. Detection and validation of QTLs for milky-white grains caused by high temperature during the ripening period in Japonica rice

    PubMed Central

    Miyahara, Katsunori; Wada, Takuya; Sonoda, Jun-ya; Tsukaguchi, Tadashi; Miyazaki, Masayuki; Tsubone, Masao; Yamaguchi, Osamu; Ishibashi, Masafumi; Iwasawa, Norio; Umemoto, Takayuki; Kondo, Motohiko

    2017-01-01

    The occurrence of chalky rice (Oryza sativa L.) grains caused by high temperature is a serious problem in rice production. Of the several kinds of chalky grains, milky-white grains are not well analyzed. The milky-white rice grain phenomenon is caused by genetic factors as well as environmental and nutritional conditions. To analyze the genetic control system for rice grain quality, we raised recombinant inbred lines from progeny produced from ‘Tsukushiroman’ (high temperature sensitive) and ‘Chikushi 52’ (high temperature tolerant) cultivars. Quantitative trait locus (QTL) analysis revealed that the QTL on chromosome 4, linked to the simple sequence repeat marker RM16424, contributed substantially to the occurrence of milky-white grains, as it was detected over two experimental years. To validate the effect of the QTL, we developed near isogenic lines that have the ‘Chikushi 52’ segment on the short arm of chromosome 4 in the ‘Tsukushiroman’ genetic background, and that had a lower milky-white grain ratio than that of ‘Tsukushiroman’ when exposed to high temperatures during the ripening period. These results suggest that the ‘Chikushi 52’ allele on chromosome 4 suppresses the occurrence of milky-white grains and improves rice grain quality under heat stress during the grain ripening period. PMID:29085242

  10. Chemical profiling and quantification of Chinese medicinal formula Huang-Lian-Jie-Du decoction, a systematic quality control strategy using ultra high performance liquid chromatography combined with hybrid quadrupole-orbitrap and triple quadrupole mass spectrometers.

    PubMed

    Yang, Yang; Wang, Hong-Jie; Yang, Jian; Brantner, Adelheid H; Lower-Nedza, Agnieszka D; Si, Nan; Song, Jian-Fang; Bai, Bing; Zhao, Hai-Yu; Bian, Bao-Lin

    2013-12-20

    To clarify and quantify the chemical profiling of Huang-Lian-Jie-Du decoction (HLJDD) rapidly, a feasible and accurate strategy was developed by applying high speed LC combined with hybrid quadrupole-orbitrap mass spectrometer (Q-Exactive) and UHPLC-triple quadruple mass spectrometer (UHPLC-QqQ MS). 69 compounds, including iridoids, alkaloids, flavonoids, triterpenoid, monoterpene and phenolic acids, were identified by their characteristic high resolution mass data. Among them, 18 major compounds were unambiguously detected by comparing with reference standards. In the subsequent quantitative analysis, 17 representative compounds, selected as quality control markers, were simultaneously detected in 10 batches of HLJDD samples by UHPLC-QqQ MS. These samples were collected from four different countries (regions). Icariin, swertiamarin and corynoline were employed as internal standards for flavonoids, iridoids and alkaloids respectively. All the analytes were detected within 12min. Polarity switching mode was used in the optimization of multiple reaction monitoring (MRM) conditions. Satisfactory linearity was achieved with wide linear range and fine determination coefficient (r(2)>0.9990). The relative standard deviations (RSD) of inter- and intra-day precisions were less than 5.0%. This method was also validated by repeatability, stability (8h) and recovery, with respective RSDs less than 4.6%, 5.0% and 6.3%. This research established a high sensitive and efficient method for the integrating quality control, including identification and quantification of Chinese medicinal formulas. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Repeatability of Spectral Domain Optical Coherence Tomography Measurements in High Myopia.

    PubMed

    Rao, Harsha L; Kumar, Addepalli U; Bonala, Sampath R; Yogesh, Kadam; Lakshmi, Bodduluri

    2016-05-01

    The purpose of this study was to compare the repeatability of spectral domain optical coherence tomography (SDOCT) parameters in high-myopic and emmetropic healthy subjects, and to evaluate the influence of axial length on the repeatability of SDOCT parameters in high myopia. In a prospective study, 93 eyes of 63 high-myopic subjects (spherical refractive error, -6 to -12 D; median age, 25 y) and 28 eyes of 14 emmetropic (spherical refractive error, 0 D; median age, 30 y) subjects underwent optic nerve head, retinal nerve fiber layer (RNFL), and ganglion cell complex imaging with SDOCT. For the repeatability analysis, 31 eyes of 31 high-myopic subjects and 14 eyes of 14 emmetropic subjects underwent 3 repeated scans in the same session. Among the optic nerve head parameters, within-subject coefficient of variation (CVw) measurements of the disc area (0.6% vs. 0.2%), rim area (8.7 vs. 2.8), and rim volume (16.7 vs. 8.9) were significantly larger (worse) in high-myopic compared with the emmetropic subjects. CVw measurements of all RNFL (range, 1.7 to 22.4) and ganglion cell complex (range, 1.8 to 2.5) parameters in high-myopic subjects were comparable to that in emmetropic subjects (2.4 to 24.0 and 1.7 to 2.0, respectively). Axial length significantly affected the CVw of nasal (coefficient, 0.01; P=0.04) and average RNFL (coefficient, 0.004; P=0.001) parameters but not that of the other SDOCT parameters. Repeatabilities of most of the SDOCT parameters in high-myopic subjects were good and comparable to that of emmetropic subjects. This suggests that SDOCT can be useful for following up high-myopic glaucoma patients to detect progression.

  12. A condition metric for Eucalyptus woodland derived from expert evaluations.

    PubMed

    Sinclair, Steve J; Bruce, Matthew J; Griffioen, Peter; Dodd, Amanda; White, Matthew D

    2018-02-01

    The evaluation of ecosystem quality is important for land-management and land-use planning. Evaluation is unavoidably subjective, and robust metrics must be based on consensus and the structured use of observations. We devised a transparent and repeatable process for building and testing ecosystem metrics based on expert data. We gathered quantitative evaluation data on the quality of hypothetical grassy woodland sites from experts. We used these data to train a model (an ensemble of 30 bagged regression trees) capable of predicting the perceived quality of similar hypothetical woodlands based on a set of 13 site variables as inputs (e.g., cover of shrubs, richness of native forbs). These variables can be measured at any site and the model implemented in a spreadsheet as a metric of woodland quality. We also investigated the number of experts required to produce an opinion data set sufficient for the construction of a metric. The model produced evaluations similar to those provided by experts, as shown by assessing the model's quality scores of expert-evaluated test sites not used to train the model. We applied the metric to 13 woodland conservation reserves and asked managers of these sites to independently evaluate their quality. To assess metric performance, we compared the model's evaluation of site quality with the managers' evaluations through multidimensional scaling. The metric performed relatively well, plotting close to the center of the space defined by the evaluators. Given the method provides data-driven consensus and repeatability, which no single human evaluator can provide, we suggest it is a valuable tool for evaluating ecosystem quality in real-world contexts. We believe our approach is applicable to any ecosystem. © 2017 State of Victoria.

  13. All-photonic quantum repeaters

    PubMed Central

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  14. Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.

    PubMed

    Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina

    2004-10-01

    We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.

  15. RAPADAPTE for rapid guideline development: high-quality clinical guidelines can be rapidly developed with limited resources.

    PubMed

    Alper, Brian S; Tristan, Mario; Ramirez-Morera, Anggie; Vreugdenhil, Maria M T; Van Zuuren, Esther J; Fedorowicz, Zbys

    2016-06-01

    Guideline development is challenging, expensive and labor-intensive. A high-quality guideline with 90 recommendations for breast cancer treatment was developed within 6 months with limited resources in Costa Rica. We describe the experience and propose a process others can use and adapt.The ADAPTE method (using existing guidelines to minimize repeating work that has been done) was used but existing guidelines were not current. The method was extended to use databases that systematically identify, appraise and synthesize evidence for clinical application (DynaMed, EBM Guidelines) to provide current evidence searches and critical appraisal of evidence. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach was used to rate the quality of evidence and the strength of recommendations. Draft recommendations with supporting evidence were provided to panel members for facilitated voting to target panel discussion to areas necessary for reaching consensus.Training panelists in guideline development methodology facilitated rapid consensus development. Extending 'guideline adaptation' to 'evidence database adaptation' was highly effective and efficient. Methods were created to simplify mapping DynaMed evidence ratings to GRADE ratings. Twelve steps are presented to facilitate rapid guideline development and enable further adaptation by others.This is a case report and the RAPADAPTE method was retrospectively derived. Prospective replication and validation will support advances for the guideline development community. If guideline development can be accelerated without compromising validity and relevance of the resulting recommendations this would greatly improve our ability to impact clinical care. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  16. Physical qualities and activity profiles of sub-elite and recreational Australian football players.

    PubMed

    Stein, Josh G; Gabbett, Tim J; Townshend, Andrew D; Dawson, Brian T

    2015-11-01

    To investigate the relationship between physical qualities and match activity profiles of recreational Australian football players. Prospective cohort study. Forty players from three recreational Australian football teams (Division One, Two and Three) underwent a battery of fitness tests (vertical jump, 10 and 40 m sprint, 6 m × 30 m repeated sprint test, Yo-Yo intermittent recovery level Two and 2-km time trial). The activity profiles of competitive match-play were quantified using 10-Hz Global Positioning System units. Division One players possessed greater maximum velocity, Yo-Yo level Two and 2-km time trial performances than Division Two and Three players. In addition, Division One players covered greater relative distance, and relative distances at moderate- and high-intensities during match-play than Division Two and Three players. Division Two players had better 2-km time trial performances than Division Three players. Positive associations (P < 0.05) were found between 10 m acceleration, maximum velocity, Yo-Yo level Two and 2-km time trial performances and relative distance, and relative distances covered at moderate- and high-intensities during match-play. Moderate relationships were found between vertical jump and relative distance and high-intensity running. Sub-elite Australian football players competing at a higher level exhibit greater physical qualities and match-play activity profiles than lesser-skilled recreational players. Acceleration and maximum velocity, 2-km time trial and Yo-Yo level Two performances discriminate between players of different playing levels, and are related to physical match performance in recreational Australian football. The development of these qualities is likely to contribute to improved match performance in recreational Australian football players. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Advancing Nursing Practice: Management of Neuropathic Pain With Capsaicin 8% Without Physician Supervision.

    PubMed

    O'Brien, Joanne; Keaveny, Joseph; Pollard, Valerie; Nugent, Linda Elizabeth

    The purpose of this study was to examine the management of patient's neuropathic pain with capsaicin 8% in a nurse-led clinic when administered by 1 registered advanced nurse practitioner without physician supervision. A longitudinal, single-group, descriptive research design was used to assess pain scores and quality of life 3 times over 3 months after treatment. Patients with a diagnosis of neuropathic pain were assessed and treated with capsaicin 8% by 1 advanced nurse practitioner with prescriptive authority in a nurse-led clinic. Pain scores were collected at baseline, and self-assessed pain, activity level, and quality of life were assessed at 1 week, 4 weeks, and 3 months after treatment. Twenty-four patients were recruited, and data were analyzed using Friedman's test. In post hoc analysis, Wilcoxon signed-rank test was used with Bonferroni correction. Pain scores differed from pretreatment to posttreatment at each of the 3 time points, at rest (χ3 = 20.54, P = .001) and on movement (χ3 = 23.644, P = .001), and remained significant after Bonferroni correction. Overall, 62.5% (n = 15) of patients achieved at least a 30% reduction in self-reported pain at rest from pretreatment to 3 months, and 54% (n = 13) achieved the same reduction in pain on movement. Most improvements in patient's quality of life occurred between 1 and 4 weeks. Patient satisfaction was high, with 83% stating that they would be happy to have the treatment repeated. Single-dose capsaicin 8% decreased neuropathic pain after being administered in an outpatient setting by an experienced registered advanced nurse practitioner. Further multicenter research led by advanced nurse practitioners is needed to support high-quality, safe treatment of neuropathic pain with high-concentration capsaicin in nurse-led chronic pain clinics.

  18. Marker-assisted introgression of opaque2 allele for rapid conversion of elite hybrids into quality protein maize.

    PubMed

    Hossain, Firoz; Muthusamy, Vignesh; Pandey, Neha; Vishwakarma, Ashish K; Baveja, Aanchal; Zunjare, Rajkumar U; Thirunavukkarasu, Nepolean; Saha, Supradip; Manjaiah, Kanchikeri M Manjaiah; Prasanna, Boddupalli M; Gupta, Hari S

    2018-03-01

    Maize is a valuable source of food and feed worldwide. Maize endosperm protein is, however nutritionally poor due to the reduced levels of two essential amino acids, lysine and tryptophan. In this study, recessive opaque2 (o2) allele that confers enhanced endosperm lysine and tryptophan, was introgressed using marker-assisted backcross breeding into three normal inbred lines (HKI323, HKI1105 and HKI1128). These are the parental lines of three popular medium-maturing single cross hybrids (HM4, HM8 and HM9) in India. Gene-based simple sequence repeat (SSR) markers (umc1066 and phi057) were successfully deployed for introgression of o2 allele. Background selection using genome-based SSRs helped in recovering > 96% of recurrent parent genome. The newly developed quality protein maize (QPM) inbreds showed modified kernels (25-50% opaqueness) coupled with high degree of phenotypic resemblance to the respective recipient lines, including grain yield. In addition, endosperm protein quality showed increased lysine and tryptophan in the inbreds to the range of 52-95% and 47-118%, respectively. The reconstituted QPM hybrids recorded significant enhancement of endosperm lysine (48-74%) and tryptophan (55-100%) in the endosperm. The QPM hybrids exhibited high phenotypic similarity with the original hybrids for morphological and yield contributing traits along with responses to some major diseases like turcicum leaf blight and maydis leaf blight. The grain yield of QPM hybrids was at par with their original versions under multilocation testing. These elite, high-yielding QPM hybrids with improved protein quality have been released and notified for commercial cultivation, and hold significant promise for improving nutritional security.

  19. Sleep Apnea Crash Risk Study (Report)

    DOT National Transportation Integrated Search

    2004-09-01

    Sleep apnea is a condition in which a narrowing or closure of the upper airway during sleep causes repeated sleep disturbances, and possible complete awakenings, leading to poor sleep quality and excessive daytime sleepiness. The primary objectives o...

  20. To Repeat or Not to Repeat a Course

    ERIC Educational Resources Information Center

    Armstrong, Michael J.; Biktimirov, Ernest N.

    2013-01-01

    The difficult transition from high school to university means that many students need to repeat (retake) 1 or more of their university courses. The authors examine the performance of students repeating first-year core courses in an undergraduate business program. They used data from university records for 116 students who took a total of 232…

  1. Population-scale whole genome sequencing identifies 271 highly polymorphic short tandem repeats from Japanese population.

    PubMed

    Hirata, Satoshi; Kojima, Kaname; Misawa, Kazuharu; Gervais, Olivier; Kawai, Yosuke; Nagasaki, Masao

    2018-05-01

    Forensic DNA typing is widely used to identify missing persons and plays a central role in forensic profiling. DNA typing usually uses capillary electrophoresis fragment analysis of PCR amplification products to detect the length of short tandem repeat (STR) markers. Here, we analyzed whole genome data from 1,070 Japanese individuals generated using massively parallel short-read sequencing of 162 paired-end bases. We have analyzed 843,473 STR loci with two to six basepair repeat units and cataloged highly polymorphic STR loci in the Japanese population. To evaluate the performance of the cataloged STR loci, we compared 23 STR loci, widely used in forensic DNA typing, with capillary electrophoresis based STR genotyping results in the Japanese population. Seventeen loci had high correlations and high call rates. The other six loci had low call rates or low correlations due to either the limitations of short-read sequencing technology, the bioinformatics tool used, or the complexity of repeat patterns. With these analyses, we have also purified the suitable 218 STR loci with four basepair repeat units and 53 loci with five basepair repeat units both for short read sequencing and PCR based technologies, which would be candidates to the actual forensic DNA typing in Japanese population.

  2. Controlled dehydration improves the diffraction quality of two RNA crystals.

    PubMed

    Park, HaJeung; Tran, Tuan; Lee, Jun Hyuck; Park, Hyun; Disney, Matthew D

    2016-11-03

    Post-crystallization dehydration methods, applying either vapor diffusion or humidity control devices, have been widely used to improve the diffraction quality of protein crystals. Despite the fact that RNA crystals tend to diffract poorly, there is a dearth of reports on the application of dehydration methods to improve the diffraction quality of RNA crystals. We use dehydration techniques with a Free Mounting System (FMS, a humidity control device) to recover the poor diffraction quality of RNA crystals. These approaches were applied to RNA constructs that model various RNA-mediated repeat expansion disorders. The method we describe herein could serve as a general tool to improve diffraction quality of RNA crystals to facilitate structure determinations.

  3. Improving the Quality of Welding Seam of Automatic Welding of Buckets Based on TCP

    NASA Astrophysics Data System (ADS)

    Hu, Min

    2018-02-01

    Since February 2014, the welding defects of the automatic welding line of buckets have been frequently appeared. The average repair time of each bucket is 26min, which seriously affects the production efficiency and welding quality. We conducted troubleshooting, and found the main reasons for the welding defects of the buckets were the deviations of the center points of the robot tools and the poor quality of the locating welding. We corrected the gripper, welding torch, and accuracy of repeat positioning of robots to control the quality of positioning welding. The welding defect rate of buckets was reduced greatly, ensuring the production efficiency and welding quality.

  4. Effects of Task Planning and Rhetorical Mode of Writing on Lexical Complexity, Syntactic Complexity, and Overall Writing Quality of EFL Writers' Task Performance

    ERIC Educational Resources Information Center

    Yildiz, Mine; Yesilyurt, Savas

    2017-01-01

    Based on Robinson's Triadic Componential Framework and the definition of task planning by Ellis (2005), this study was carried out to find out the effects of task planning and rhetorical mode on lexical and syntactic complexity, and overall writing quality of writing production of EFL learners. Following a repeated-measures design, the present…

  5. Using creative problem solving (TRIZ) in improving the quality of hospital services.

    PubMed

    LariSemnani, Behrouz; Mohebbi Far, Rafat; Shalipoor, Elham; Mohseni, Mohammad

    2014-08-14

    TRIZ is an initiative and SERVQUAL is a structured methodology for quality improvement. Using these tools, inventive problem solving can be applied for quality improvement, and the highest quality can be reached using creative quality improvement methodology. The present study seeks to determine the priority of quality aspects of services provided for patients in the hospital as well as how TRIZ can help in improving the quality of those services. This Study is an applied research which used a dynamic qualitative descriptive survey method during year 2011. Statistical population includes every patient who visited in one of the University Hospitals from March 2011. There existed a big gap between patients' expectations from what seemingly is seen (the design of the hospital) and timely provision of services with their perceptions. Also, quality aspects of services were prioritized as follows: keeping the appearance of hospital (the design), accountability, assurance, credibility and having empathy. Thus, the only thing which mattered most for all staff and managers of studied hospital was the appearance of hospital as well as its staff look. This can grasp a high percentage of patients' satisfaction. By referring to contradiction matrix, the most important principles of TRIZ model were related to tangible factors including principles No. 13 (discarding and recovering), 25 (self-service), 35 (parameter changes), and 2 (taking out). Furthermore, in addition to these four principles, principle No. 24 (intermediary) was repeated most among the others. By utilizing TRIZ, hospital problems can be examined with a more open view, Go beyond The conceptual framework of the organization and responded more quickly to patients ' needs.

  6. Informative genomic microsatellite markers for efficient genotyping applications in sugarcane.

    PubMed

    Parida, Swarup K; Kalia, Sanjay K; Kaul, Sunita; Dalal, Vivek; Hemaprabha, G; Selvi, Athiappan; Pandit, Awadhesh; Singh, Archana; Gaikwad, Kishor; Sharma, Tilak R; Srivastava, Prem Shankar; Singh, Nagendra K; Mohapatra, Trilochan

    2009-01-01

    Genomic microsatellite markers are capable of revealing high degree of polymorphism. Sugarcane (Saccharum sp.), having a complex polyploid genome requires more number of such informative markers for various applications in genetics and breeding. With the objective of generating a large set of microsatellite markers designated as Sugarcane Enriched Genomic MicroSatellite (SEGMS), 6,318 clones from genomic libraries of two hybrid sugarcane cultivars enriched with 18 different microsatellite repeat-motifs were sequenced to generate 4.16 Mb high-quality sequences. Microsatellites were identified in 1,261 of the 5,742 non-redundant clones that accounted for 22% enrichment of the libraries. Retro-transposon association was observed for 23.1% of the identified microsatellites. The utility of the microsatellite containing genomic sequences were demonstrated by higher primer designing potential (90%) and PCR amplification efficiency (87.4%). A total of 1,315 markers including 567 class I microsatellite markers were designed and placed in the public domain for unrestricted use. The level of polymorphism detected by these markers among sugarcane species, genera, and varieties was 88.6%, while cross-transferability rate was 93.2% within Saccharum complex and 25% to cereals. Cloning and sequencing of size variant amplicons revealed that the variation in the number of repeat-units was the main source of SEGMS fragment length polymorphism. High level of polymorphism and wide range of genetic diversity (0.16-0.82 with an average of 0.44) assayed with the SEGMS markers suggested their usefulness in various genotyping applications in sugarcane.

  7. Novel Round Energy Director for Use with Servo-driven Ultrasonic Welder

    NASA Astrophysics Data System (ADS)

    Savitski, Alex; Klinstein, Leo; Holt, Kenneth

    Increasingly stringent process repeatability and precision of assembly requirements are common for high-volume manufacturing for electronic, automotive and especially medical device industries, in which components for disposable medication delivery devices are produced in hundreds of millions annually. Ultrasonic welding, one of the most efficient of plastic welding processes often joins these small plastic parts together, and quite possibly, the one most broadly adopted for high volume assembly. The very fundamental factor in ultrasonic welding process performance is a proper joint design, the most common of which is a design utilizing an energy director. Keeping the energy director size and shape consistent on a part-to-part basis in high volume, multi-cavity operations presents a constant challenge to molded part vendors, as dimensional variations from cavity to cavity and variations in the molding process are always present. A newly developed concept of energy director design, when the tip of the energy director is round, addresses these problems, as the round energy director is significantly easier to mold and maintain its dimensional consistency. It also eliminates a major source of process variability for assembly operations. Materializing the benefits of new type of joint design became possible with the introduction of servo-driven ultrasonic welders, which allow an unprecedented control of material flow during the welding cycle and results in significantly improved process repeatability. This article summarizes results of recent studies focused on evaluating performance of round energy director and investigating the main factors responsible for the joint quality.

  8. Highly Processed and Ready-to-Eat Packaged Food and Beverage Purchases Differ by Race/Ethnicity among US Households.

    PubMed

    Poti, Jennifer M; Mendez, Michelle A; Ng, Shu Wen; Popkin, Barry M

    2016-09-01

    Racial/ethnic disparities in dietary quality persist among Americans, but it is unclear whether highly processed foods or convenience foods contribute to these inequalities. We examined the independent associations of race/ethnicity with highly processed and ready-to-eat (RTE) food purchases among US households. We determined whether controlling for between-group differences in purchases of these products attenuated associations between race/ethnicity and the nutritional quality of purchases. The 2000-2012 Homescan Panel followed US households (n = 157,142) that scanned their consumer packaged goods (CPG) food and beverage purchases. By using repeated-measures regression models adjusted for sociodemographic characteristics, we examined time-varying associations of race/ethnicity with processed and convenience food purchases, expressed as a percentage of calories purchased. We estimated associations between race/ethnicity and saturated fat, sugar, or energy density of total purchases with and without adjustment for processed and convenience food purchases. Compared with white households, black households had significantly lower purchases of highly processed foods (-4.1% kcal) and RTE convenience foods (-4.9% kcal) and had higher purchases of basic processed foods, particularly cooking oils and sugar (+5.4% kcal), foods requiring cooking/preparation (+4.5% kcal), and highly processed beverages (+7.1% kcal). Hispanics also had lower purchases of highly processed and RTE foods than whites. Blacks had CPG purchases with significantly higher median sugar (+2.2% kcal) and energy density (+72 kcal/1000 g), whereas Hispanics had purchases with lower saturated fat (-0.6% kcal) and energy density (-25 kcal/1000 g) than whites. Racial/ethnic differences remained significant after adjustment for processed and convenience food purchases. In our study, compared with white households, both black and Hispanic households had lower purchases of highly processed and RTE foods, yet had total CPG purchases with differing nutritional quality. Our findings suggest that highly processed convenience foods are associated with, but cannot fully explain, racial/ethnic disparities in the nutritional quality of CPG purchases. © 2016 American Society for Nutrition.

  9. Highly Processed and Ready-to-Eat Packaged Food and Beverage Purchases Differ by Race/Ethnicity among US Households123

    PubMed Central

    Mendez, Michelle A

    2016-01-01

    Background: Racial/ethnic disparities in dietary quality persist among Americans, but it is unclear whether highly processed foods or convenience foods contribute to these inequalities. Objective: We examined the independent associations of race/ethnicity with highly processed and ready-to-eat (RTE) food purchases among US households. We determined whether controlling for between-group differences in purchases of these products attenuated associations between race/ethnicity and the nutritional quality of purchases. Methods: The 2000–2012 Homescan Panel followed US households (n = 157,142) that scanned their consumer packaged goods (CPG) food and beverage purchases. By using repeated-measures regression models adjusted for sociodemographic characteristics, we examined time-varying associations of race/ethnicity with processed and convenience food purchases, expressed as a percentage of calories purchased. We estimated associations between race/ethnicity and saturated fat, sugar, or energy density of total purchases with and without adjustment for processed and convenience food purchases. Results: Compared with white households, black households had significantly lower purchases of highly processed foods (–4.1% kcal) and RTE convenience foods (–4.9% kcal) and had higher purchases of basic processed foods, particularly cooking oils and sugar (+5.4% kcal), foods requiring cooking/preparation (+4.5% kcal), and highly processed beverages (+7.1% kcal). Hispanics also had lower purchases of highly processed and RTE foods than whites. Blacks had CPG purchases with significantly higher median sugar (+2.2% kcal) and energy density (+72 kcal/1000 g), whereas Hispanics had purchases with lower saturated fat (–0.6% kcal) and energy density (–25 kcal/1000 g) than whites. Racial/ethnic differences remained significant after adjustment for processed and convenience food purchases. Conclusions: In our study, compared with white households, both black and Hispanic households had lower purchases of highly processed and RTE foods, yet had total CPG purchases with differing nutritional quality. Our findings suggest that highly processed convenience foods are associated with, but cannot fully explain, racial/ethnic disparities in the nutritional quality of CPG purchases. PMID:27466605

  10. Phase Variation of NadA in Invasive Neisseria meningitidis Isolates Impacts on Coverage Estimates for 4C-MenB, a MenB vaccine.

    PubMed

    Green, Luke R; Lucidarme, Jay; Dave, Neelam; Chan, Hannah; Clark, Stephen; Borrow, Ray; Bayliss, Christopher D

    2018-06-27

    A recombinant NadA protein is one of the four major protective antigens of 4C-MenB (Bexsero®), a vaccine developed for serogroup B Neisseria meningitidis (MenB). The Meningococcal Antigen Typing System (MATS) is utilised as a high throughput assay for assessing the invasive MenB strain coverage of 4C-MenB. Where present, the nadA gene is subject to phase variable changes in transcription due to a 5'TAAA repeat tract located in a regulatory region. The promoter-containing intergenic region sequences (IGR) and 5'TAAA repeat numbers were determined for 906 invasive meningococcal disease isolates possessing the nadA gene. Exclusion of the 5'TAAA repeats reduced the number of IGR alleles from 82 to 23. Repeat numbers were associated with low and high levels of NadA expression by Western blotting and ELISA. Low expression repeat numbers were present in 83% of 179 MenB isolates with NadA-2/3 or Nad-1 peptide variants and 68% of 480 MenW ST-11 complex isolates with Nad-2/3 peptide variants. For isolates with vaccine-compatible NadA variants, 93% of MATS negative isolates were associated with low expression repeat numbers whereas 63% of isolates with MATS RP scores above the 95% confidence interval for the positive bactericidal threshold had high expression repeat numbers. Analysis of the 5'TAAA repeat number has potential as a rapid, high throughput method for assessing strain coverage for the NadA-component of 4C-MenB. A key application will be assessing coverage in meningococcal disease cases where confirmation is by PCR only and MATS cannot be applied. Copyright © 2018 Green et al.

  11. The Effects of Vegetative Type, Edges, Fire History, Rainfall and Management in Fire-Maintained Ecosystems

    NASA Technical Reports Server (NTRS)

    Breininger, David R.; Foster, Tammy E.; Carter, Geoffrey M.; Duncan, Brean W.; Stolen, Eric D.; Lyon, James E.

    2017-01-01

    The combined effects of repeated fires, climate, and landscape features (e.g., edges) need greater focus in fire ecology studies, which usually emphasize characteristics of the most recent fire and not fire history. Florida scrub-jays are an imperiled, territorial species that prefer medium (1.2-1.7 m) shrub heights. We measured short, medium, and tall habitat quality states annually within 10 ha grid cells that represented potential territories because frequent fires and vegetative recovery cause annual variation in habitat quality. We used multistate models and model selection to test competing hypotheses about how transition probabilities between states varied annually as functions of environmental covariates. Covariates included vegetative type, edges, precipitation, openings (gaps between shrubs), mechanical cutting, and fire characteristics. Fire characteristics not only included an annual presenceabsence of fire covariate, but also fire history covariates: time since the previous fire, the maximum fire-free interval, and the number of repeated fires. Statistical models with support included many covariates for each transition probability, often including fire history, interactions and nonlinear relationships. Tall territories resulted from 28 years of fire suppression and habitat fragmentation that reduced the spread of fires across landscapes. Despite 35 years of habitat restoration and prescribed fires, half the territories remained tall suggesting a regime shift to a less desirable habitat condition. Measuring territory quality states and environmental covariates each year combined with multistate modeling provided a useful empirical approach to quantify the effects of repeated fire in combinations with environmental variables on transition probabilities that drive management strategies and ecosystem change.

  12. Consensus and controversies in best practices for molecular genetic testing of spinocerebellar ataxias

    PubMed Central

    Sequeiros, Jorge; Seneca, Sara; Martindale, Joanne

    2010-01-01

    Many laboratories worldwide are offering molecular genetic testing for spinocerebellar ataxias (SCAs). This is essential for differential diagnosis and adequate genetic counselling. The European Molecular Genetics Quality Network (EMQN) started an SCA external quality assessment scheme in 2004. There was a clear need for updated laboratory guidelines. EMQN and EuroGentest organized a Best Practice (BP) meeting to discuss current practices and achieve consensus. A pre-meeting survey showed that 36 laboratories (20 countries) conducted nearly 18 000 SCA tests the year before, and identified issues to discuss. Draft guidelines were produced immediately after the meeting and discussed online for several months. The final version was endorsed by EMQN, and harmonized with guidelines from other oligonucleotide repeat disorders. We present the procedures taken to organize the survey, BP meeting, as well as drafting and approval of BP guidelines. We emphasize the most important recommendations on (1) pre-test requirements, (2) appropriate methodologies and (3) interpretation and reporting, and focus on the discussion of controversial issues not included in the final document. In addition, after an extensive review of scientific literature, and responding to recommendations made, we now produce information that we hope will facilitate the activities of diagnostic laboratories and foster quality SCA testing. For the main loci, this includes (1) a list of repeat sequences, as originally published; (2) primers in use; and (3) an evidence-based description of the normal and pathogenic repeat-size ranges, including those of reduced penetrance and those in which there is still some uncertainty. This information will be maintained and updated in http://www.scabase.eu. PMID:20179748

  13. Procedure for maximizing oocyte harvest for in vitro embryo production in small ruminants.

    PubMed

    Gibbons, A; Pereyra Bonnet, F; Cueto, M I; Catala, M; Salamone, D F; Gonzalez-Bulnes, A

    2007-08-01

    Possible effects of repeated hormonal treatments and laparoscopic ovum pick-up (LOPU) on the efficiency of oocyte recovery rate and quality were determined in sheep and goats. In six adult Merino sheep and five Criolla goats, ovarian status was synchronized by a prostaglandin F(2 alpha) analogue and the insertion of an intravaginal sponge 48 h later. Follicle development was stimulated by a single dose of FSH (60 mg NIH-FSH-P1) plus a single dose of equine chorionic gonadotrophin (eCG; 300 UI). The first FSH/eCG doses were administered 48 h after the sponge insertion, being repeated every 4 days to complete a total of four treatments in sheep and three in goats. Follicles in both ovaries were categorized according to their diameter and follicular fluid was aspirated under laparoscopic observation without a vacuum pump. In sheep, during a 12-day-period, a total of 347 follicles were aspirated with a recovery rate of 46.9%. In goats, during an 8-day-period, 219 follicles were aspirated with a recovery rate of 45.6%. In both species, there were no significant differences in the number of aspirated follicles, oocyte recovery rate and good quality oocyte recovery rate. However, in sheep the oocyte recovery rate was higher for large follicles, whereas in goats no such effect was detected. In summary, current results indicate that retrieval of oocytes can be maximized, without affecting oocyte quality, by repeating 'oneshot' FSH/eCG regimes and LOPUs at intervals as short as 4 days.

  14. van der Waals epitaxial two-dimensional CdSxSe(1-x) semiconductor alloys with tunable-composition and application to flexible optoelectronics.

    PubMed

    Xia, Jing; Zhao, Yun-Xuan; Wang, Lei; Li, Xuan-Ze; Gu, Yi-Yi; Cheng, Hua-Qiu; Meng, Xiang-Min

    2017-09-21

    Despite the substantial progress in the development of two-dimensional (2D) materials from conventional layered crystals, it still remains particularly challenging to produce high-quality 2D non-layered semiconductor alloys which may bring in some unique properties and new functions. In this work, the synthesis of well-oriented 2D non-layered CdS x Se (1-x) semiconductor alloy flakes with tunable compositions and optical properties is established. Structural analysis reveals that the 2D non-layered alloys follow an incommensurate van der Waals epitaxial growth pattern. Photoluminescence measurements show that the 2D alloys have composition-dependent direct bandgaps with the emission peak varying from 1.8 eV to 2.3 eV, coinciding well with the density functional theory calculations. Furthermore, photodetectors based on the CdS x Se (1-x) flakes exhibit a high photoresponsivity of 703 A W -1 with an external quantum efficiency of 1.94 × 10 3 and a response time of 39 ms. Flexible devices fabricated on a thin mica substrate display good mechanical stability upon repeated bending. This work suggests a facile and general method to produce high-quality 2D non-layered semiconductor alloys for next-generation optoelectronic devices.

  15. Quality evaluation of Shenmaidihuang Pills based on the chromatographic fingerprints and simultaneous determination of seven bioactive constituents.

    PubMed

    Liu, Sifei; Zhang, Guangrui; Qiu, Ying; Wang, Xiaobo; Guo, Lihan; Zhao, Yanxin; Tong, Meng; Wei, Lan; Sun, Lixin

    2016-12-01

    In this study, we aimed to establish a comprehensive and practical quality evaluation system for Shenmaidihuang pills. A simple and reliable high-performance liquid chromatography coupled with photodiode array detection method was developed both for fingerprint analysis and quantitative determination. In fingerprint analysis, relative retention time and relative peak area were used to identify the common peaks in 18 samples for investigation. Twenty one peaks were selected as the common peaks to evaluate the similarities of 18 Shenmaidihuang pills samples with different manufacture dates. Furthermore, similarity analysis was applied to evaluate the similarity of samples. Hierarchical cluster analysis and principal component analysis were also performed to evaluate the variation of Shenmaidihuang pills. In quantitative analysis, linear regressions, injection precisions, recovery, repeatability and sample stability were all tested and good results were obtained to simultaneously determine the seven identified compounds, namely, 5-hydroxymethylfurfural, morroniside, loganin, paeonol, paeoniflorin, psoralen, isopsoralen in Shenmaidihuang pills. The contents of some analytes in different batches of samples indicated significant difference, especially for 5-hydroxymethylfurfural. So, it was concluded that the chromatographic fingerprint method obtained by high-performance liquid chromatography coupled with photodiode array detection associated with multiple compounds determination is a powerful and meaningful tool to comprehensively conduct the quality control of Shenmaidihuang pills. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Quality evaluation of Radix Astragali through a simultaneous determination of six major active isoflavonoids and four main saponins by high-performance liquid chromatography coupled with diode array and evaporative light scattering detectors.

    PubMed

    Qi, Lian-Wen; Yu, Qing-Tao; Li, Ping; Li, Song-Lin; Wang, Yu-Xia; Sheng, Liang-Hong; Yi, Ling

    2006-11-17

    A method, high-performance liquid chromatography coupled with diode array and evaporative light scattering detectors (HPLC-DAD-ELSD), was developed to evaluate the quality of Radix Astragali through a simultaneous determination of six major active isoflavonoids and four main saponins. The wavelength at 280 nm was chosen to determine six isoflavonoids: calycosin-7-O-beta-D-glucoside (1), ononin (2), (6alphaR, 11alphaR)-9,10-dimethoxypterocarpan-3-O-beta-D-glucoside (3), (3R)-2'-hydroxy-3',4'-dimethoxyisoflavan-7-O-beta-D-glucoside (4), calycosin (5), and formononetin (6); and ELSD connected after DAD was employed to determine four saponins: astragaloside IV (7), astragaloside II (8), astragaloside I (9), and acetylastragaloside I (10). This assay was fully validated with respect to precision, repeatability and accuracy. The proposed method was successfully applied to quantify the ten components in eleven samples from different localities in China; significant variations were demonstrated in the content of these compounds in the samples from different areas. This simple, rapid, low-cost and reliable HPLC-DAD-ELSD method is suitable for routine quantitative analysis and quality control of traditional Chinese medicines (TCMs) consisting of bioactive multi-components with different structures such as Radix Astragali.

  17. Effects of stressful life events in young black men with high blood pressure.

    PubMed

    Han, Hae-Ra; Kim, Miyong T; Rose, Linda; Dennison, Cheryl; Bone, Lee; Hill, Martha N

    2006-01-01

    1) To describe stressful life events as experienced by a sample of young Black men with high blood pressure (HBP) living in inner-city Baltimore, Maryland; and 2) to examine the effect of cumulative stressful life events on substance use, depression, and quality of life. Data were obtained over 48 months by interview from 210 men in an HBP management study. Stressors repeatedly occurring over time included death of family member or close friend (65.2%), having a new family member (32.9%), change in residence (31.4%), difficulty finding a job (24.3%), and fired or laid off from work (17.6%). Involvement with crime or legal matters was reported at least twice during the 48 months by 33.3% of men. When a cumulative stressful life events score was calculated by summing the number of events experienced at 6-month points over 48 months and tested for its relationship with the health outcomes, the findings of multivariate analyses revealed significant associations between cumulative life stressors and depression and quality of life. No significant relationship was found between stressful life events and substance use. The results suggest that cumulative stressful life events have a negative effect on mental health and quality of life in young Black men with HBP. Future study should focus on developing interventions to assist individuals in managing distress related to stressful events with necessary community resources.

  18. Repeated-sprint ability and team selection in Australian football league players.

    PubMed

    Le Rossignol, Peter; Gabbett, Tim J; Comerford, Dan; Stanton, Warren R

    2014-01-01

    To investigate the relationship between selected physical capacities and repeated-sprint performance of Australian Football League (AFL) players and to determine which physical capacities contributed to being selected for the first competition game. Sum of skinfolds, 40-m sprint (with 10-, 20-, 30-, and 40-m splits), repeated-sprint ability (6 × 30-m sprints), and 3-km-run time were measured during the preseason in 20 AFL players. The physical qualities of players selected to play the first match of the season and those not selected were compared. Pearson correlation coefficients were used to determine the relationship among variables, and a regression analysis identified variables significantly related to repeated-sprint performance. In the regression analysis, maximum velocity was the best predictor of repeated-sprint time, with 3-km-run time also contributing significantly to the predictive model. Sum of skinfolds was significantly correlated with 10-m (r = .61, P < .01) and 30-m (r = .53, P < .05) sprint times. A 2.6% ± 2.1% difference in repeated-sprint time (P < .05, ES = 0.88 ± 0.72) was observed between those selected (25.26 ± 0.55 s) and not selected (25.82 ± 0.80 s) for the first game of the season. The findings indicate that maximum-velocity training using intervals of 30-40 m may contribute more to improving repeated-sprint performance in AFL players than short 10- to 20-m intervals from standing starts. Further research is warranted to establish the relative importance of endurance training for improving repeated-sprint performance in AFL football.

  19. The Complementary Use of Audience Response Systems and Online Tests to Implement Repeat Testing: A Case Study

    ERIC Educational Resources Information Center

    Stratling, Rebecca

    2017-01-01

    Although learning theories suggest that repeat testing can be highly beneficial for students' retention and understanding of material, there is, so far, little guidance on how to implement repeat testing in higher education. This paper introduces one method for implementing a three-stage model of repeat testing via computer-aided formative…

  20. Community College Nursing Students' Experience of Repeating a Course after Academic Failure

    ERIC Educational Resources Information Center

    Lewis, Lisa Scandale

    2016-01-01

    This narrative inquiry study looked at community college nursing student repeaters, those who have failed a required nursing course and then gone on to repeat the course. Nursing student repeaters are a population at especially high risk for attrition, and about whom little is known. The community college setting is an important site of nursing…

  1. The Water Quality in Rio Highlights the Global Public Health ...

    EPA Pesticide Factsheets

    Water quality issues in Rio have been widely publicized because of the 2016 Olympics. Recent concerns about polluted waters that athletes may be exposed to highlights the conditions that more than a billion people globally are exposed to daily. Despite these unhealthy conditions, much is unknown about the risks and exposure pathways associated with bathing in or drinking untreated or partially treated sewage. Beyond acute illness, we are learning more about the chronic sequelae that arise from repeated exposure to pathogens found in sewage. Additionally, we do not know enough about how to measure water quality, especially in developing countries. A consequence of these knowledge gaps is that data from developed countries are used to guide public health approaches in low· and middle-income settings. More data that are locally specific are needed to inform guidelines for improving sanitation and water quality in Rio and other cities in developing countries. Recent media reports of high levels of sewage contamination have caused wide-ranging concerns about the safety of sailing, rowing, and other open water events at the upcoming Olympics. This commentary discusses the global public health problem of exposures to untreated sewage and describes the need for context specific solutions to monitoring and communication and risk assessment.

  2. A Music-Related Quality of Life Measure to Guide Music Rehabilitation for Adult Cochlear Implant Users.

    PubMed

    Dritsakis, Giorgos; van Besouw, Rachel M; Kitterick, Pádraig; Verschuur, Carl A

    2017-09-18

    A music-related quality of life (MuRQoL) questionnaire was developed for the evaluation of music rehabilitation for adult cochlear implant (CI) users. The present studies were aimed at refinement and validation. Twenty-four experts reviewed the MuRQoL items for face validity. A refined version was completed by 147 adult CI users, and psychometric techniques were used for item selection, assessment of reliability, and definition of the factor structure. The same participants completed the Short Form Health Survey for construct validation. MuRQoL responses from 68 CI users were compared with those of a matched group of adults with normal hearing. Eighteen items measuring music perception and engagement and 18 items measuring their importance were selected; they grouped together into 2 domains. The final questionnaire has high internal consistency and repeatability. Significant differences between CI users and adults with normal hearing and a correlation between music engagement and quality of life support construct validity. Scores of music perception and engagement and importance for the 18 items can be combined to assess the impact of music on the quality of life. The MuRQoL questionnaire is a reliable and valid measure of self-reported music perception, engagement, and their importance for adult CI users with potential to guide music aural rehabilitation.

  3. Quality Improvement Initiative for Family-Centered Care in the Neonatal Intensive Care Unit of a Tertiary Hospital in South Africa.

    PubMed

    Maree, Carin; Kekana, Poppy; van der Walt, Christa; Yazbek, Mariatha; Leech, Ronell

    The introduction of family-centered care in the neonatal intensive care unit was identified as a high priority to facilitate bonding and attachment with potential positive outcomes for the parents and infants. The aim of the study was, therefore, to develop and implement a quality improvement initiative to foster family-centered care in a tertiary neonatal intensive care unit from birth onward. A pretest posttest intervention design was used using mixed methods over 3 phases to determine the perceived level of family-centered care according to healthcare professionals and parents using self-administered questionnaires; to develop and implement a quality improvement initiative to enhance family-centered care in a neonatal intensive care unit using a nominal group technique, followed by the quality improvement process; and to evaluate the outcomes of the initiative by repeating the self-administered questionnaires to parents and staff. Various activities were introduced as part of the initiative such as early breastfeeding, early introduction of parents to their infant, open visitation policy, and involvement in caring activities. The perceived level of care according to staff and parents increased. It is expected to enhance bonding and attachment between the infants and their parents, with consequential long-term positive outcomes.

  4. Repeat sequence chromosome specific nucleic acid probes and methods of preparing and using

    DOEpatents

    Weier, H.U.G.; Gray, J.W.

    1995-06-27

    A primer directed DNA amplification method to isolate efficiently chromosome-specific repeated DNA wherein degenerate oligonucleotide primers are used is disclosed. The probes produced are a heterogeneous mixture that can be used with blocking DNA as a chromosome-specific staining reagent, and/or the elements of the mixture can be screened for high specificity, size and/or high degree of repetition among other parameters. The degenerate primers are sets of primers that vary in sequence but are substantially complementary to highly repeated nucleic acid sequences, preferably clustered within the template DNA, for example, pericentromeric alpha satellite repeat sequences. The template DNA is preferably chromosome-specific. Exemplary primers and probes are disclosed. The probes of this invention can be used to determine the number of chromosomes of a specific type in metaphase spreads, in germ line and/or somatic cell interphase nuclei, micronuclei and/or in tissue sections. Also provided is a method to select arbitrarily repeat sequence probes that can be screened for chromosome-specificity. 18 figs.

  5. Repeat sequence chromosome specific nucleic acid probes and methods of preparing and using

    DOEpatents

    Weier, Heinz-Ulrich G.; Gray, Joe W.

    1995-01-01

    A primer directed DNA amplification method to isolate efficiently chromosome-specific repeated DNA wherein degenerate oligonucleotide primers are used is disclosed. The probes produced are a heterogeneous mixture that can be used with blocking DNA as a chromosome-specific staining reagent, and/or the elements of the mixture can be screened for high specificity, size and/or high degree of repetition among other parameters. The degenerate primers are sets of primers that vary in sequence but are substantially complementary to highly repeated nucleic acid sequences, preferably clustered within the template DNA, for example, pericentromeric alpha satellite repeat sequences. The template DNA is preferably chromosome-specific. Exemplary primers ard probes are disclosed. The probes of this invention can be used to determine the number of chromosomes of a specific type in metaphase spreads, in germ line and/or somatic cell interphase nuclei, micronuclei and/or in tissue sections. Also provided is a method to select arbitrarily repeat sequence probes that can be screened for chromosome-specificity.

  6. Lower neurocognitive function in U-2 pilots

    PubMed Central

    Tate, David F.; Wood, Joe; Sladky, John H.; McDonald, Kent; Sherman, Paul M.; Kawano, Elaine S.; Rowland, Laura M.; Patel, Beenish; Wright, Susan N.; Hong, Elliot; Rasmussen, Jennifer; Willis, Adam M.; Kochunov, Peter V.

    2014-01-01

    Objective: Determine whether United States Air Force (USAF) U-2 pilots (U2Ps) with occupational exposure to repeated hypobaria had lower neurocognitive performance compared to pilots without repeated hypobaric exposure and whether U2P neurocognitive performance correlated with white matter hyperintensity (WMH) burden. Methods: We collected Multidimensional Aptitude Battery–II (MAB-II) and MicroCog: Assessment of Cognitive Functioning (MicroCog) neurocognitive data on USAF U2Ps with a history of repeated occupational exposure to hypobaria and compared these with control data collected from USAF pilots (AFPs) without repeated hypobaric exposure (U2Ps/AFPs MAB-II 87/83; MicroCog 93/80). Additional comparisons were performed between U2Ps with high vs low WMH burden. Results: U2Ps with repeated hypobaric exposure had significantly lower scores than control pilots on reasoning/calculation (U2Ps/AFPs 99.4/106.5), memory (105.5/110.9), information processing accuracy (102.1/105.8), and general cognitive functioning (103.5/108.5). In addition, U2Ps with high whole-brain WMH count showed significantly lower scores on reasoning/calculation (high/low 96.8/104.1), memory (102.9/110.2), general cognitive functioning (101.5/107.2), and general cognitive proficiency (103.6/108.8) than U2Ps with low WMH burden (high/low WMH mean volume 0.213/0.003 cm3 and mean count 14.2/0.4). Conclusion: In these otherwise healthy, highly functioning individuals, pilots with occupational exposure to repeated hypobaria demonstrated lower neurocognitive performance, albeit demonstrable on only some tests, than pilots without repeated exposure. Furthermore, within the U2P population, higher WMH burden was associated with lower neurocognitive test performance. Hypobaric exposure may be a risk factor for subtle changes in neurocognition. PMID:25008397

  7. Assessment of "YouTube" Content for Distal Radius Fracture Immobilization.

    PubMed

    Addar, Abdullah; Marwan, Yousef; Algarni, Nizar; Berry, Gregory

    Distal radius fractures (DRFs) are the most common orthopedic fractures, with >70% of cases treated by closed immobilization using a short arm cast or a sugar tong splint. However, inadequate immobilization is a risk factor for loss of reduction requiring repeat reduction or surgical treatment. Therefore, education of clinical skills for appropriate immobilization of DRFs is important. With the increasing use of web-based information by medical learners, our aim was to assess the quality and quantity of videos regarding closed immobilization of DRFs on YouTube. Retrospective review of YouTube videos on distal radius fracture immobilization using specific search terms. Identified videos were analyzed for their educational value, quality of the technical skill demonstrated, and overall metrics. Educational value was scored on a 5-point scale, with "1" indicative of low quality and "5" of high quality. Not applicable. Among the 68,366 videos identified, 16 met our inclusion criteria of being in English; performed by a health care professional or institution; and with casting being the major theme of the educational information provided. Of these 16 videos, 6 had an educational value score of 4 or 5, with the remaining 10 having a score ≤3. Although immobilization was demonstrated by cast technician specialized in orthopedics, skills were also performed by orthopedic attendants, urgent care physicians, orthopedic residents, and nurse practitioners. The credentials of the performer in 3 videos were not identified. There is a need to promote high-quality educational videos produced by established medical school faculty members on open, web-based, portals. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  8. Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2017-01-01

    Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.

  9. Lessons learned from implementing a wet laboratory molecular training workshop for beach water quality monitoring.

    PubMed

    Verhougstraete, Marc Paul; Brothers, Sydney; Litaker, Wayne; Blackwood, A Denene; Noble, Rachel

    2015-01-01

    Rapid molecular testing methods are poised to replace many of the conventional, culture-based tests currently used in fields such as water quality and food science. Rapid qPCR methods have the benefit of being faster than conventional methods and provide a means to more accurately protect public health. However, many scientists and technicians in water and food quality microbiology laboratories have limited experience using these molecular tests. To ensure that practitioners can use and implement qPCR techniques successfully, we developed a week long workshop to provide hands-on training and exposure to rapid molecular methods for water quality management. This workshop trained academic professors, government employees, private industry representatives, and graduate students in rapid qPCR methods for monitoring recreational water quality. Attendees were immersed in these new methods with hands-on laboratory sessions, lectures, and one-on-one training. Upon completion, the attendees gained sufficient knowledge and practice to teach and share these new molecular techniques with colleagues at their respective laboratories. Key findings from this workshop demonstrated: 1) participants with no prior experience could be effectively trained to conduct highly repeatable qPCR analysis in one week; 2) participants with different desirable outcomes required exposure to a range of different platforms and sample processing approaches; and 3) the collaborative interaction amongst newly trained practitioners, workshop leaders, and members of the water quality community helped foster a cohesive cohort of individuals which can advocate powerful cohort for proper implementation of molecular methods.

  10. Lessons Learned from Implementing a Wet Laboratory Molecular Training Workshop for Beach Water Quality Monitoring

    PubMed Central

    Verhougstraete, Marc Paul; Brothers, Sydney; Litaker, Wayne; Blackwood, A. Denene; Noble, Rachel

    2015-01-01

    Rapid molecular testing methods are poised to replace many of the conventional, culture-based tests currently used in fields such as water quality and food science. Rapid qPCR methods have the benefit of being faster than conventional methods and provide a means to more accurately protect public health. However, many scientists and technicians in water and food quality microbiology laboratories have limited experience using these molecular tests. To ensure that practitioners can use and implement qPCR techniques successfully, we developed a week long workshop to provide hands-on training and exposure to rapid molecular methods for water quality management. This workshop trained academic professors, government employees, private industry representatives, and graduate students in rapid qPCR methods for monitoring recreational water quality. Attendees were immersed in these new methods with hands-on laboratory sessions, lectures, and one-on-one training. Upon completion, the attendees gained sufficient knowledge and practice to teach and share these new molecular techniques with colleagues at their respective laboratories. Key findings from this workshop demonstrated: 1) participants with no prior experience could be effectively trained to conduct highly repeatable qPCR analysis in one week; 2) participants with different desirable outcomes required exposure to a range of different platforms and sample processing approaches; and 3) the collaborative interaction amongst newly trained practitioners, workshop leaders, and members of the water quality community helped foster a cohesive cohort of individuals which can advocate powerful cohort for proper implementation of molecular methods. PMID:25822486

  11. Pulsed coherent population trapping with repeated queries for producing single-peaked high contrast Ramsey interference

    NASA Astrophysics Data System (ADS)

    Warren, Z.; Shahriar, M. S.; Tripathi, R.; Pati, G. S.

    2018-02-01

    A repeated query technique has been demonstrated as a new interrogation method in pulsed coherent population trapping for producing single-peaked Ramsey interference with high contrast. This technique enhances the contrast of the central Ramsey fringe by nearly 1.5 times and significantly suppresses the side fringes by using more query pulses ( >10) in the pulse cycle. Theoretical models have been developed to simulate Ramsey interference and analyze the characteristics of the Ramsey spectrum produced by the repeated query technique. Experiments have also been carried out employing a repeated query technique in a prototype rubidium clock to study its frequency stability performance.

  12. Production of a high-velocity water slug using an impacting technique.

    PubMed

    Dehkhoda, S; Bourne, N K

    2014-02-01

    A pulsed water jet consists of a series of discrete water slugs travelling at high velocity. Immediately after striking a target, these slugs apply high-intensity, short-duration transient stress pulses reaching an amplitude known as the water hammer pressure, followed by low-intensity, long-duration stationary stress at a lower stagnation pressure. The magnitude and duration of the water hammer and stagnation pressures are controlled by the size and quality of the water slugs. The use of water jets for rock cutting in mining operations is a centuries-old technology; however, practical methods for producing high-energy water slugs repeatedly have proven difficult. This can be partly due to the fact that the geometrical properties of a jet and so its effectiveness in creating damage is controlled and influenced by the method that is employed to generate the water slugs. This paper investigates the quality of a single water slug produced using an impacting technique where a hammer strikes a piston, resting on top of a water-filled chamber. The coherence and integrity of the jet core was of concern in this study. The impact impulse of the formed water jet was measured in a Kel-F target material using an embedded PVDF (Polyvinylidene fluoride) shock gauge. The recorded stress waveform was then used to determine the unity and endurance of the water slug stream once travelled through air.

  13. Production of a high-velocity water slug using an impacting technique

    NASA Astrophysics Data System (ADS)

    Dehkhoda, S.; Bourne, N. K.

    2014-02-01

    A pulsed water jet consists of a series of discrete water slugs travelling at high velocity. Immediately after striking a target, these slugs apply high-intensity, short-duration transient stress pulses reaching an amplitude known as the water hammer pressure, followed by low-intensity, long-duration stationary stress at a lower stagnation pressure. The magnitude and duration of the water hammer and stagnation pressures are controlled by the size and quality of the water slugs. The use of water jets for rock cutting in mining operations is a centuries-old technology; however, practical methods for producing high-energy water slugs repeatedly have proven difficult. This can be partly due to the fact that the geometrical properties of a jet and so its effectiveness in creating damage is controlled and influenced by the method that is employed to generate the water slugs. This paper investigates the quality of a single water slug produced using an impacting technique where a hammer strikes a piston, resting on top of a water-filled chamber. The coherence and integrity of the jet core was of concern in this study. The impact impulse of the formed water jet was measured in a Kel-F target material using an embedded PVDF (Polyvinylidene fluoride) shock gauge. The recorded stress waveform was then used to determine the unity and endurance of the water slug stream once travelled through air.

  14. Disruptive and Sustaining Technology Development Approaches in Defense Acquisition

    DTIC Science & Technology

    2014-04-30

    feature for the emerging personal computer market. Disruptive innovation also operates on the scale of an entire market. The story of Eastman Kodak ...quality pictures, it was only available to those with expertise in, and desire to, chemically process the film. The Kodak box camera took lower quality...into a niche market. A century later the scenario repeated itself in amateur photography. Kodak had become locked into their century-old business

  15. Contribution of wetlands to nitrate removal at the watershed scale

    NASA Astrophysics Data System (ADS)

    Hansen, Amy T.; Dolph, Christine L.; Foufoula-Georgiou, Efi; Finlay, Jacques C.

    2018-02-01

    Intensively managed row crop agriculture has fundamentally changed Earth surface processes within the Mississippi River basin through large-scale alterations of land cover, hydrology and reactive nitrogen availability. These changes have created leaky landscapes where excess agriculturally derived nitrate degrades riverine water quality at local, regional and continental scales. Individually, wetlands are known to remove nitrate but the conditions under which multiple wetlands meaningfully reduce riverine nitrate concentration have not been established. Only one region of the Mississippi River basin—the 44,000 km2 Minnesota River basin—still contains enough wetland cover within its intensively agriculturally managed watersheds to empirically address this question. Here we combine high-resolution land cover data for the Minnesota River basin with spatially extensive repeat water sampling data. By clearly isolating the effect of wetlands from crop cover, we show that, under moderate-high streamflow, wetlands are five times more efficient per unit area at reducing riverine nitrate concentration than the most effective land-based nitrogen mitigation strategies, which include cover crops and land retirement. Our results suggest that wetland restorations that account for the effects of spatial position in stream networks could provide a much greater benefit to water quality then previously assumed.

  16. A concept for early cancer detection and therapy

    NASA Astrophysics Data System (ADS)

    Waynant, Ronald W.; Ilev, Ilko K.; Mitra, Kunal

    2003-06-01

    Early detection and treatment of breast cancer is least costly in terms of dollars, morbidity and mortality. With new early detection x-ray technology, tumors can be found, diagnosed and treated at a much smaller size than is currently possible. This paper proposes the development of a high resolution, high quality imaging system. It is a laser-driven x-ray system with time-gated detection that removes scattering noise in the image and produces resolution on the order of 10 μm. This higher resolution and higher image quality will enable the detection of one or two millimeter tumors hopefully detecting them before metastasis. We also propose that tumor detection should be followed by an immediate needle-directed, optical fiber biopsy to instantly determine if cancer is present and, if present, the tumor should immediately be given a lethal treatment of laser or x-radiation through the same needle using fiber optics or hollow waveguides. This technology will help prevent multiple interventions resulting in both the lowest overall cost and a more efficacious therapy. The approach can be stopped at the first negative (benign) indication and will help forestall repeated examination as well as reduce patient anxiety.

  17. About Small Streams and Shiny Rocks: Macromolecular Crystal Growth in Microfluidics

    NASA Technical Reports Server (NTRS)

    vanderWoerd, Mark; Ferree, Darren; Spearing, Scott; Monaco, Lisa; Molho, Josh; Spaid, Michael; Brasseur, Mike; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    We are developing a novel technique with which we have grown diffraction quality protein crystals in very small volumes, utilizing chip-based, microfluidic ("LabChip") technology. With this technology volumes smaller than achievable with any laboratory pipette can be dispensed with high accuracy. We have performed a feasibility study in which we crystallized several proteins with the aid of a LabChip device. The protein crystals are of excellent quality as shown by X-ray diffraction. The advantages of this new technology include improved accuracy of dispensing for small volumes, complete mixing of solution constituents without bubble formation, highly repeatable recipe and growth condition replication, and easy automation of the method. We have designed a first LabChip device specifically for protein crystallization in batch mode and can reliably dispense and mix from a range of solution constituents. We are currently testing this design. Upon completion additional crystallization techniques, such as vapor diffusion and liquid-liquid diffusion will be accommodated. Macromolecular crystallization using microfluidic technology is envisioned as a fully automated system, which will use the 'tele-science' concept of remote operation and will be developed into a research facility aboard the International Space Station.

  18. Nanomagnetism study of highly-ordered iron oxide nanocrystal assemblies fabricated by the Langmuir-Blodgett technique.

    PubMed

    Zhang, HaiTao; Bao, NiNa; Yuan, Du; Ding, Jun

    2013-09-21

    Iron oxide nanocrystals are ideal building blocks for the construction of flexible nanodevices whose performance can be modulated by controlling the morphology of isolated particles and their organizational form. This work demonstrates the fabrication of high quality Langmuir-Blodgett (LB) nanocrystal assemblies with limited overlapping and higher coverage by systemically and combinatorially optimizing the parameters of compression pressure and quantity of spread nanocrystals. Monodispersed iron oxide nanocrystals with a diameter of 11.8 nm were synthesized by thermal decomposition of Fe(CO)5 in trioctylamine with the presence of oleic acid. Multilayer nanocrystal assemblies were obtained through a layer-by-layer (LBL) process by repeating the transfer procedure after their hydrophilicity had been improved via treatment in a UV-ozone oven. The quality of nanocrystal assemblies was investigated by UV-vis spectrometry and scanning electron microscopy. The nanomagnetism for the nanostructures of different combination manners was studied systemically by a superconducting quantum interference device (SQUID). A lower superparamagnetic blocking temperature was found in the monolayer Fe3O4 nanocrystal assembly. The superparamagnetic blocking temperature in magnetic nanocrystal assemblies could be tuned through modifying the interparticle interactions among the interlayer and intralayers by controlling the layer number of the assemblies.

  19. ARA type protograph codes

    NASA Technical Reports Server (NTRS)

    Divsalar, Dariush (Inventor); Abbasfar, Aliazam (Inventor); Jones, Christopher R. (Inventor); Dolinar, Samuel J. (Inventor); Thorpe, Jeremy C. (Inventor); Andrews, Kenneth S. (Inventor); Yao, Kung (Inventor)

    2008-01-01

    An apparatus and method for encoding low-density parity check codes. Together with a repeater, an interleaver and an accumulator, the apparatus comprises a precoder, thus forming accumulate-repeat-accumulate (ARA codes). Protographs representing various types of ARA codes, including AR3A, AR4A and ARJA codes, are described. High performance is obtained when compared to the performance of current repeat-accumulate (RA) or irregular-repeat-accumulate (IRA) codes.

  20. Where in the world are my field plots? Using GPS effectively in environmental field studies

    USGS Publications Warehouse

    Johnson, Chris E.; Barton, Christopher C.

    2004-01-01

    Global positioning system (GPS) technology is rapidly replacing tape, compass, and traditional surveying instruments as the preferred tool for estimating the positions of environmental research sites. One important problem, however, is that it can be difficult to estimate the uncertainty of GPS-derived positions. Sources of error include various satellite- and site-related factors, such as forest canopy and topographic obstructions. In a case study from the Hubbard Brook Experimental Forest in New Hampshire, hand-held, mapping-grade GPS receivers generally estimated positions with 1–5 m precision in open, unobstructed settings, and 20–30 m precision under forest canopy. Surveying-grade receivers achieved precisions of 10 cm or less, even in challenging terrain. Users can maximize the quality of their GPS measurements by “mission planning” to take advantage of high-quality satellite conditions. Repeated measurements and simultaneous data collection at multiple points can be used to assess accuracy and precision.

  1. Fast machine-learning online optimization of ultra-cold-atom experiments.

    PubMed

    Wigley, P B; Everitt, P J; van den Hengel, A; Bastian, J W; Sooriyabandara, M A; McDonald, G D; Hardman, K S; Quinlivan, C D; Manju, P; Kuhn, C C N; Petersen, I R; Luiten, A N; Hope, J J; Robins, N P; Hush, M R

    2016-05-16

    We apply an online optimization process based on machine learning to the production of Bose-Einstein condensates (BEC). BEC is typically created with an exponential evaporation ramp that is optimal for ergodic dynamics with two-body s-wave interactions and no other loss rates, but likely sub-optimal for real experiments. Through repeated machine-controlled scientific experimentation and observations our 'learner' discovers an optimal evaporation ramp for BEC production. In contrast to previous work, our learner uses a Gaussian process to develop a statistical model of the relationship between the parameters it controls and the quality of the BEC produced. We demonstrate that the Gaussian process machine learner is able to discover a ramp that produces high quality BECs in 10 times fewer iterations than a previously used online optimization technique. Furthermore, we show the internal model developed can be used to determine which parameters are essential in BEC creation and which are unimportant, providing insight into the optimization process of the system.

  2. Fast machine-learning online optimization of ultra-cold-atom experiments

    PubMed Central

    Wigley, P. B.; Everitt, P. J.; van den Hengel, A.; Bastian, J. W.; Sooriyabandara, M. A.; McDonald, G. D.; Hardman, K. S.; Quinlivan, C. D.; Manju, P.; Kuhn, C. C. N.; Petersen, I. R.; Luiten, A. N.; Hope, J. J.; Robins, N. P.; Hush, M. R.

    2016-01-01

    We apply an online optimization process based on machine learning to the production of Bose-Einstein condensates (BEC). BEC is typically created with an exponential evaporation ramp that is optimal for ergodic dynamics with two-body s-wave interactions and no other loss rates, but likely sub-optimal for real experiments. Through repeated machine-controlled scientific experimentation and observations our ‘learner’ discovers an optimal evaporation ramp for BEC production. In contrast to previous work, our learner uses a Gaussian process to develop a statistical model of the relationship between the parameters it controls and the quality of the BEC produced. We demonstrate that the Gaussian process machine learner is able to discover a ramp that produces high quality BECs in 10 times fewer iterations than a previously used online optimization technique. Furthermore, we show the internal model developed can be used to determine which parameters are essential in BEC creation and which are unimportant, providing insight into the optimization process of the system. PMID:27180805

  3. Experimental study and empirical prediction of fuel flow parameters under air evolution conditions

    NASA Astrophysics Data System (ADS)

    Kitanina, E. E.; Kitanin, E. L.; Bondarenko, D. A.; Kravtsov, P. A.; Peganova, M. M.; Stepanov, S. G.; Zherebzov, V. L.

    2017-11-01

    Air evolution in kerosene under the effect of gravity flow with various hydraulic resistances in the pipeline was studied experimentally. The study was conducted at pressure ranging from 0.2 to 1.0 bar and temperature varying between -20°C and +20°C. Through these experiments, the oversaturation limit beyond which dissolved air starts evolving intensively from the fuel was established and the correlations for the calculation of pressure losses and air evolution on local loss elements were obtained. A method of calculating two-phase flow behaviour in a titled pipeline segment with very low mass flow quality and fairly high volume flow quality was developed. The complete set of empirical correlations obtained by experimental analysis was implemented in the engineering code. The software simulation results were repeatedly verified against our experimental findings and Airbus test data to show that the two-phase flow simulation agrees quite well with the experimental results obtained in the complex branched pipelines.

  4. The psychiatric nurse specialist: a valuable asset in the general hospital.

    PubMed

    Fife, B; Lemler, S

    1983-04-01

    In summary, what are the ways in which the psychiatric/mental clinical specialist contributes to cost-effectiveness, the professional growth of nursing staff, and quality patient care in the general hospital setting? All services of the psychiatric/mental health clinical specialist are ultimately directed toward increasing the effectiveness with which staff can deliver care. This goal is accomplished by helping staff nurses maximize their knowledge, by providing needed educational opportunities, by promoting the use of a holistic model of care, and by helping staff cope with their own stress. In our experience, high quality care that meets the physiological, psychological, and sociological needs of patients decreases the length of the hospital stay, prevents repeated hospitalizations, and minimizes the development of psychosocial problems secondary to the illness. With the necessary support and cooperation from administration, this clinical specialist role reduces health care costs, promotes a higher level of functioning in patients and their families, and increases the level of job satisfaction for the staff who provide direct bedside care.

  5. A Spiritually Based Group Intervention for Combat Veterans With Posttraumatic Stress Disorder

    PubMed Central

    Bormann, Jill E.; Thorp, Steven; Wetherell, Julie L.; Golshan, Shahrokh

    2014-01-01

    Purpose To assess the feasibility, effect sizes, and satisfaction of mantram repetition—the spiritual practice of repeating a sacred word/phrase throughout the day—for managing symptoms of posttraumatic stress disorder (PTSD) in veterans. Design A two group (intervention vs. control) by two time (pre- and postintervention) experimental design was used. Methods Veterans were randomly assigned to intervention (n = 14) or delayed-treatment control (n = 15). Measures were PTSD symptoms, psychological distress, quality of life, and patient satisfaction. Effect sizes were calculated using Cohen’s d. Findings Thirty-three male veterans were enrolled, and 29 (88%) completed the study. Large effect sizes were found for reducing PTSD symptom severity (d = −.72), psychological distress (d = −.73) and increasing quality of life (d = .70). Conclusions A spiritual program was found to be feasible for veterans with PTSD. They reported moderate to high satisfaction. Effect sizes show promise for symptom improvement but more research is needed. PMID:18356284

  6. Rapid Measurement and Correction of Phase Errors from B0 Eddy Currents: Impact on Image Quality for Non-Cartesian Imaging

    PubMed Central

    Brodsky, Ethan K.; Klaers, Jessica L.; Samsonov, Alexey A.; Kijowski, Richard; Block, Walter F.

    2014-01-01

    Non-Cartesian imaging sequences and navigational methods can be more sensitive to scanner imperfections that have little impact on conventional clinical sequences, an issue which has repeatedly complicated the commercialization of these techniques by frustrating transitions to multi-center evaluations. One such imperfection is phase errors caused by resonant frequency shifts from eddy currents induced in the cryostat by time-varying gradients, a phenomemon known as B0 eddy currents. These phase errors can have a substantial impact on sequences that use ramp sampling, bipolar gradients, and readouts at varying azimuthal angles. We present a method for measuring and correcting phase errors from B0 eddy currents and examine the results on two different scanner models. This technique yields significant improvements in image quality for high-resolution joint imaging on certain scanners. The results suggest that correction of short time B0 eddy currents in manufacturer provided service routines would simplify adoption of non-Cartesian sampling methods. PMID:22488532

  7. A study of the Huntington's disease associated trinucleotide repeat in the Scottish population.

    PubMed Central

    Barron, L H; Warner, J P; Porteous, M; Holloway, S; Simpson, S; Davidson, R; Brock, D J

    1993-01-01

    Accurate measurements of a specific CAG repeat sequence in the Huntington's disease (HD) gene in 337 HD patients and 229 normal controls from the Scottish population showed a range from 35 to 62 repeats in affected subjects and eight to 33 in normal subjects. A link between early onset of symptoms and very high repeat number was seen. For HD patients with the most common affected allele sizes (39 to 42 repeats) absolute repeat size was a poor index for the age at onset of symptoms. There was variability in the transmitted repeat size for both sexes in the HD size range. We observed a significant increase of repeat size for paternal transmission of the disease and greater instability for paternally transmitted CAG repeats in the HD size range. Images PMID:8133495

  8. Development of a cell-based qualitative assay for detection of neutralizing anti-human interleukin-1 receptor antagonist (hIL-1Ra) antibodies in rats.

    PubMed

    Gao, Jin; Li, Jingjing; Yang, Minmin; Wu, Mingyuan; Tu, Ping; Yu, Yan; Han, Wei

    2015-01-01

    To determine the incidence of the positive neutralizing anti-human interleukin receptor antagonist (anti-IL-1Ra), a novel assay based on the proliferation of human melanoma A375.S2 cells was developed and validated. In the presence of a growth-limiting concentration of IL-1β, A375.S2 cells were able to regain proliferation following the addition of IL-1Ra in a concentration-dependent manner. This dose-response effect enabled the validation of a standard curve for calculation of the concentration of IL-1Ra or, inversely, the concentration of neutralizing anti-IL-1Ra antibodies in cell culture medium or sera. The assay used CCK-8 as an indicator of proliferation. The dose-response relationship between rhIL-1Ra (dose range of 5-75 ng/ml rhIL-1Ra) and A375.S2 cell proliferation was sigmoidal and fitted a four-parameter logistic model. The percent coefficients of variation (%CVs) of quality control samples were 12.5 and 11.9% for intra-assay repeatability and 14.5 and 19.5% for inter-assay repeatability, while the total accuracy was in the range of 97.2-103.6%. For the neutralization assay, the optimal sample dilution factor was found to be 40-fold and the reasonable standard for positive and negative decision was calculated to be 59.4% neutralization rate. The %CVs of quality control samples were 12.7 and 24.0% for intra-assay repeatability and 11.6 and 30.0% for inter-assay repeatability. Analysis using the assay showed that rats could produce neutralizing anti-IL-1Ra antibodies after repeated intramuscular injection with rhIL-1Ra, and this response was not significantly dependent on the dose injected.

  9. Older people and falls: health status, quality of life, lifestyle, care networks, prevention and views on service use following a recent fall.

    PubMed

    Roe, Brenda; Howell, Fiona; Riniotis, Konstantinos; Beech, Roger; Crome, Peter; Ong, Bie Nio

    2009-08-01

    This study has investigated older people's experiences of a recent fall, its impact on their health, lifestyle, quality of life, care networks, prevention and their views on service use. Falls are common in older people and prevalence increases with age. Falls prevention is a major policy and service initiative. An exploratory, qualitative design involving two time points. A convenience sample of 27 older people from two primary care trusts who had a recent fall. Taped semi structured qualitative interviews were conducted and repeated at follow up to detect change over time and repeat falls. Data were collected on their experience of falls, health, activities of living, lifestyle, quality of life, use of services, prevention of falls, informal care and social networks. Content analysis of transcribed interviews identified key themes. The majority of people fell indoors (n = 23), were repeat fallers (n = 22) with more than half alone when they fell (n = 15). For five people it was their first ever fall. Participants in primary care trust 1 had a higher mean age than those in primary care trust 2 and had more injurious falls (n = 12, mean age 87 years vs. n = 15, mean age 81 years). The majority of non-injurious falls went unreported to formal services. Falls can result in a decline in health status, ability to undertake activities of living, lifestyle and quality of life. Local informal care and support networks are as important as formal care for older people at risk of falls or who have fallen. Access to falls prevention programmes and services is limited for people living in more rural communities. Falls prevention initiatives and services should work with local communities, agencies and informal carers to ensure equitable access and provision of information, resources and care to meet the needs of older people at risk or who have fallen.

  10. Identification and characterization of tandem repeats in exon III of dopamine receptor D4 (DRD4) genes from different mammalian species.

    PubMed

    Larsen, Svend Arild; Mogensen, Line; Dietz, Rune; Baagøe, Hans Jørgen; Andersen, Mogens; Werge, Thomas; Rasmussen, Henrik Berg

    2005-12-01

    In this study we have identified and characterized dopamine receptor D4 (DRD4) exon III tandem repeats in 33 public available nucleotide sequences from different mammalian species. We found that the tandem repeat in canids could be described in a novel and simple way, namely, as a structure composed of 15- and 12- bp modules. Tandem repeats composed of 18-bp modules were found in sequences from the horse, zebra, onager, and donkey, Asiatic bear, polar bear, common raccoon, dolphin, harbor porpoise, and domestic cat. Several of these sequences have been analyzed previously without a tandem repeat being found. In the domestic cow and gray seal we identified tandem repeats composed of 36-bp modules, each consisting of two closely related 18-bp basic units. A tandem repeat consisting of 9-bp modules was identified in sequences from mink and ferret. In the European otter we detected an 18-bp tandem repeat, while a tandem repeat consisting of 27-bp modules was identified in a sequence from European badger. Both these tandem repeats were composed of 9-bp basic units, which were closely related with the 9-bp repeat modules identified in the mink and ferret. Tandem repeats could not be identified in sequences from rodents. All tandem repeats possessed a high GC content with a strong bias for C. On phylogenetic analysis of the tandem repeats evolutionary related species were clustered into the same groups. The degree of conservation of the tandem repeats varied significantly between species. The deduced amino acid sequences of most of the tandem repeats exhibited a high propensity for disorder. This was also the case with an amino acid sequence of the human DRD4 exon III tandem repeat, which was included in the study for comparative purposes. We identified proline-containing motifs for SH3 and WW domain binding proteins, potential phosphorylation sites, PDZ domain binding motifs, and FHA domain binding motifs in the amino acid sequences of the tandem repeats. The numbers of potential functional sites varied pronouncedly between species. Our observations provide a platform for future studies of the architecture and evolution of the DRD4 exon III tandem repeat, and they suggest that differences in the structure of this tandem repeat contribute to specialization and generation of diversity in receptor function.

  11. GFP-based fluorescence assay for CAG repeat instability in cultured human cells.

    PubMed

    Santillan, Beatriz A; Moye, Christopher; Mittelman, David; Wilson, John H

    2014-01-01

    Trinucleotide repeats can be highly unstable, mutating far more frequently than point mutations. Repeats typically mutate by addition or loss of units of the repeat. CAG repeat expansions in humans trigger neurological diseases that include myotonic dystrophy, Huntington disease, and several spinocerebellar ataxias. In human cells, diverse mechanisms promote CAG repeat instability, and in mice, the mechanisms of instability are varied and tissue-dependent. Dissection of mechanistic complexity and discovery of potential therapeutics necessitates quantitative and scalable screens for repeat mutation. We describe a GFP-based assay for screening modifiers of CAG repeat instability in human cells. The assay exploits an engineered intronic CAG repeat tract that interferes with expression of an inducible GFP minigene. Like the phenotypes of many trinucleotide repeat disorders, we find that GFP function is impaired by repeat expansion, in a length-dependent manner. The intensity of fluorescence varies inversely with repeat length, allowing estimates of repeat tract changes in live cells. We validate the assay using transcription through the repeat and engineered CAG-specific nucleases, which have previously been reported to induce CAG repeat instability. The assay is relatively fast and should be adaptable to large-scale screens of chemical and shRNA libraries.

  12. GFP-Based Fluorescence Assay for CAG Repeat Instability in Cultured Human Cells

    PubMed Central

    Santillan, Beatriz A.; Moye, Christopher; Mittelman, David; Wilson, John H.

    2014-01-01

    Trinucleotide repeats can be highly unstable, mutating far more frequently than point mutations. Repeats typically mutate by addition or loss of units of the repeat. CAG repeat expansions in humans trigger neurological diseases that include myotonic dystrophy, Huntington disease, and several spinocerebellar ataxias. In human cells, diverse mechanisms promote CAG repeat instability, and in mice, the mechanisms of instability are varied and tissue-dependent. Dissection of mechanistic complexity and discovery of potential therapeutics necessitates quantitative and scalable screens for repeat mutation. We describe a GFP-based assay for screening modifiers of CAG repeat instability in human cells. The assay exploits an engineered intronic CAG repeat tract that interferes with expression of an inducible GFP minigene. Like the phenotypes of many trinucleotide repeat disorders, we find that GFP function is impaired by repeat expansion, in a length-dependent manner. The intensity of fluorescence varies inversely with repeat length, allowing estimates of repeat tract changes in live cells. We validate the assay using transcription through the repeat and engineered CAG-specific nucleases, which have previously been reported to induce CAG repeat instability. The assay is relatively fast and should be adaptable to large-scale screens of chemical and shRNA libraries. PMID:25423602

  13. Tafamidis delays disease progression in patients with early stage transthyretin familial amyloid polyneuropathy: additional supportive analyses from the pivotal trial.

    PubMed

    Keohane, Denis; Schwartz, Jeffrey; Gundapaneni, Balarama; Stewart, Michelle; Amass, Leslie

    2017-03-01

    Tafamidis, a non-NSAID highly specific transthyretin stabilizer, delayed neurologic disease progression as measured by Neuropathy Impairment Score-Lower Limbs (NIS-LL) in an 18-month, double-blind, placebo-controlled randomized trial in 128 patients with early-stage transthyretin V30M familial amyloid polyneuropathy (ATTRV30M-FAP). The current post hoc analyses aimed to further evaluate the effects of tafamidis in delaying ATTRV30M-FAP progression in this trial. Pre-specified, repeated-measures analysis of change from baseline in NIS-LL in this trial (ClinicalTrials.gov NCT00409175) was repeated with addition of baseline as covariate and multiple imputation analysis for missing data by treatment group. Change in NIS-LL plus three small-fiber nerve tests (NIS-LL + Σ3) and NIS-LL plus seven nerve tests (NIS-LL + Σ7) were assessed without baseline as covariate. Treatment outcomes over the NIS-LL, Σ3, Σ7, modified body mass index and Norfolk Quality of Life-Diabetic Neuropathy Total Quality of Life Score were also examined using multivariate analysis techniques. Neuropathy progression based on NIS-LL change from baseline to Month 18 remained significantly reduced for tafamidis versus placebo in the baseline-adjusted and multiple imputation analyses. NIS-LL + Σ3 and NIS-LL + Σ7 captured significant treatment group differences. Multivariate analyses provided strong statistical evidence for a superior tafamidis treatment effect. These supportive analyses confirm that tafamidis delays neurologic progression in early-stage ATTRV30M-FAP. NCT00409175.

  14. The effect of giving global coronary risk information to adults: a systematic review.

    PubMed

    Sheridan, Stacey L; Viera, Anthony J; Krantz, Mori J; Ice, Christa L; Steinman, Lesley E; Peters, Karen E; Kopin, Laurie A; Lungelow, Danielle

    2010-02-08

    Global coronary heart disease (CHD) risk estimation (ie, a quantitative estimate of a patient's chances of CHD calculated by combining risk factors in an empirical equation) is recommended as a starting point for primary prevention efforts in all US adults. Whether it improves outcomes is currently unknown. To assess the effect of providing global CHD risk information to adults, we performed a systematic evidence review. We searched MEDLINE for the years 1980 to 2008, Psych Info, CINAHL, and the Cochrane Database and included English-language articles that met prespecified inclusion criteria. Two reviewers independently reviewed titles, abstracts, and articles for inclusion and assessed study quality. We identified 20 articles, reporting on 18 unique fair or good quality studies (including 14 randomized controlled studies). These showed that global CHD risk information alone or with accompanying education increased the accuracy of perceived risk and probably increased intent to start therapy. Studies with repeated risk information or risk information and repeated doses of counseling showed small significant reductions in predicted CHD risk (absolute differences, -0.2% to -2% over 10 years in studies using risk estimates derived from Framingham equations). Studies providing global risk information at only 1 point in time seemed ineffective. Global CHD risk information seems to improve the accuracy of risk perception and may increase intent to initiate CHD prevention among individuals at moderate to high risk. The effect of global risk presentation on more distal outcomes is less clear and seems to be related to the intensity of accompanying interventions.

  15. Getting evidence-based pressure ulcer prevention into practice: a multi-faceted unit-tailored intervention in a hospital setting.

    PubMed

    Sving, Eva; Högman, Marieann; Mamhidir, Anna-Greta; Gunningberg, Lena

    2016-10-01

    The aim of the study was to evaluate whether a multi-faceted, unit-tailored intervention using evidenced-based pressure ulcer prevention affects (i) the performance of pressure ulcer prevention, (ii) the prevalence of pressure ulcers and (iii) knowledge and attitudes concerning pressure ulcer prevention among registered and assistant nurses. A quasi-experimental, clustered pre- and post-test design was used. Five units at a hospital setting were included. The intervention was based on the PARIHS framework and included a multi-professional team, training and repeated quality measurements. An established methodology was used to evaluate the prevalence and prevention of pressure ulcers. Nurses' knowledge and attitudes were evaluated using a validated questionnaire. A total of 506 patients were included, of whom 105 patients had a risk to develop pressure ulcer. More patients were provided pressure ulcer prevention care (P = 0·001) and more prevention care was given to each patient (P = 0·021) after the intervention. Corresponding results were shown in the group of patients assessed as being at risk for developing pressure ulcers. Nurses' knowledge about pressure ulcer prevention increased (P < 0·001). Positive attitudes towards pressure ulcer prevention remained high between pre- and post-test surveys. This multi-faceted unit-tailored intervention affected pressure ulcer prevention. Facilitation and repeated quality measurement together with constructed feedback of results seemed to be the most important factor for pressure ulcer prevention. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  16. Maternal sensitivity and infant autonomic and endocrine stress responses.

    PubMed

    Bosquet Enlow, Michelle; King, Lucy; Schreier, Hannah Mc; Howard, Jamie M; Rosenfield, David; Ritz, Thomas; Wright, Rosalind J

    2014-07-01

    Early environmental exposures may help shape the development of the autonomic nervous system (ANS) and hypothalamic-pituitary-adrenal (HPA) axis, influencing vulnerability for health problems across the lifespan. Little is known about the role of maternal sensitivity in influencing the development of the ANS in early life. To examine associations among maternal sensitivity and infant behavioral distress and ANS and HPA axis reactivity to the Repeated Still-Face Paradigm (SFP-R), a dyadic stress task. Observational repeated measures study. Thirty-five urban, sociodemographically diverse mothers and their 6-month-old infants. Changes in infant affective distress, heart rate, respiratory sinus arrhythmia (RSA), and T-wave amplitude (TWA) across episodes of the SFP-R were assessed. A measure of cortisol output (area under the curve) in the hour following cessation of the SFP-R was also obtained. Greater maternal insensitivity was associated with greater infant sympathetic activation (TWA) during periods of stress and tended to be associated with greater cortisol output following the SFP-R. There was also evidence for greater affective distress and less parasympathetic activation (RSA) during the SFP-R among infants of predominantly insensitive mothers. Caregiving quality in early life may influence the responsiveness of the sympathetic and parasympathetic branches of the ANS as well as the HPA axis. Consideration of the ANS and HPA axis systems together provides a fuller representation of adaptive versus maladaptive stress responses. The findings highlight the importance of supporting high quality caregiving in the early years of life, which is likely to promote later health. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Structural Basis of Egg Coat-Sperm Recognition at Fertilization.

    PubMed

    Raj, Isha; Sadat Al Hosseini, Hamed; Dioguardi, Elisa; Nishimura, Kaoru; Han, Ling; Villa, Alessandra; de Sanctis, Daniele; Jovine, Luca

    2017-06-15

    Recognition between sperm and the egg surface marks the beginning of life in all sexually reproducing organisms. This fundamental biological event depends on the species-specific interaction between rapidly evolving counterpart molecules on the gametes. We report biochemical, crystallographic, and mutational studies of domain repeats 1-3 of invertebrate egg coat protein VERL and their interaction with cognate sperm protein lysin. VERL repeats fold like the functionally essential N-terminal repeat of mammalian sperm receptor ZP2, whose structure is also described here. Whereas sequence-divergent repeat 1 does not bind lysin, repeat 3 binds it non-species specifically via a high-affinity, largely hydrophobic interface. Due to its intermediate binding affinity, repeat 2 selectively interacts with lysin from the same species. Exposure of a highly positively charged surface of VERL-bound lysin suggests that complex formation both disrupts the organization of egg coat filaments and triggers their electrostatic repulsion, thereby opening a hole for sperm penetration and fusion. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  18. Parturition date for a given female is highly repeatable within five roe deer populations

    PubMed Central

    Plard, Floriane; Gaillard, Jean-Michel; Bonenfant, Christophe; Hewison, A. J. Mark; Delorme, Daniel; Cargnelutti, Bruno; Kjellander, Petter; Nilsen, Erlend B.; Coulson, Tim

    2013-01-01

    Births are highly synchronized among females in many mammal populations in temperate areas. Although laying date for a given female is also repeatable within populations of birds, limited evidence suggests low repeatability of parturition date for individual females in mammals, and between-population variability in repeatability has never, to our knowledge, been assessed. We quantified the repeatability of parturition date for individual females in five populations of roe deer, which we found to vary between 0.54 and 0.93. Each year, some females gave birth consistently earlier in the year, whereas others gave birth consistently later. In addition, all females followed the same lifetime trajectory for parturition date, giving birth progressively earlier as they aged. Giving birth early should allow mothers to increase offspring survival, although few females managed to do so. The marked repeatability of parturition date in roe deer females is the highest ever reported for a mammal, suggesting low phenotypic plasticity in this trait. PMID:23234861

  19. Parturition date for a given female is highly repeatable within five roe deer populations.

    PubMed

    Plard, Floriane; Gaillard, Jean-Michel; Bonenfant, Christophe; Hewison, A J Mark; Delorme, Daniel; Cargnelutti, Bruno; Kjellander, Petter; Nilsen, Erlend B; Coulson, Tim

    2013-02-23

    Births are highly synchronized among females in many mammal populations in temperate areas. Although laying date for a given female is also repeatable within populations of birds, limited evidence suggests low repeatability of parturition date for individual females in mammals, and between-population variability in repeatability has never, to our knowledge, been assessed. We quantified the repeatability of parturition date for individual females in five populations of roe deer, which we found to vary between 0.54 and 0.93. Each year, some females gave birth consistently earlier in the year, whereas others gave birth consistently later. In addition, all females followed the same lifetime trajectory for parturition date, giving birth progressively earlier as they aged. Giving birth early should allow mothers to increase offspring survival, although few females managed to do so. The marked repeatability of parturition date in roe deer females is the highest ever reported for a mammal, suggesting low phenotypic plasticity in this trait.

  20. Running With the Pack: Teen Peer-Relationship Qualities as Predictors of Adult Physical Health

    PubMed Central

    Allen, Joseph P.; Uchino, Bert N.; Hafen, Christopher A.

    2015-01-01

    This study assessed qualities of adolescent peer relationships as long-term predictors of physical health quality in adulthood. In an intensive multimethod, multireporter study of a community sample of 171 individuals assessed repeatedly from the ages of 13 to 27 years, physical health quality in adulthood was robustly predicted by independent reports of early-adolescent close-friendship quality and by a pattern of acquiescence to social norms in adolescent peer relationships. Predictions remained after accounting for numerous potential confounds, including prior health problems, concurrent body mass index, anxious and depressive symptoms, personality characteristics, adolescent-era financial adversity, and adolescent-era physical attractiveness. These findings have important implications for understanding the unique intensity of peer relationships in adolescence. PMID:26290522

  1. Androgen receptor CAG repeat polymorphisms in canine prostate cancer.

    PubMed

    Lai, C-L; L'Eplattenier, H; van den Ham, R; Verseijden, F; Jagtenberg, A; Mol, J A; Teske, E

    2008-01-01

    Relatively shorter lengths of the polymorphic polyglutamine repeat-1 of the androgen receptor (AR) have been associated with an increased risk of prostate cancer (PC) in humans. In the dog, there are 2 polymorphic CAG repeat (CAGr) regions. To investigate the relationship of CAGr length of the canine AR-gene and the development of PC. Thirty-two dogs with PC and 172 control dogs were used. DNA was extracted from blood. Both CAG repeats were amplified by polymerase chain reaction (PCR) and PCR products were sequenced. In dogs with PC, CAG-1 repeat length was shorter (P = .001) by an increased proportion of 10 repeats (P = .011) and no 12 repeats (P = .0017) than in the control dogs. No significant changes were found in CAG-3 length distribution. CAG-1 and CAG-3 polymorphisms proved not to be in linkage disequilibrium. Breed difference in allelic distribution was found in the control group. Of the prostate-disease sensitive breeds, a high percentage (64.5%) of the shortest haplotype 10/11 was found in the Doberman, whereas Beagles and German Pointers had higher haplotype 12/11 (47.1 and 50%). Bernese Mountain dogs and Bouvier dogs both shared a high percentage of 11 CAG-1 repeats and 13 CAG-3 repeats. Differences in (combined) allelic distributions among breeds were not significant. In this preliminary study, short CAG-1 repeats in the AR-gene were associated with an increased risk of developing canine PC. Although breed-specific differences in allelic distribution of CAG-1 and CAG-3 repeats were found, these could not be related to PC risk.

  2. Criminal Behavior and Repeat Violent Trauma: A Case-Control Study.

    PubMed

    Nanney, John T; Conrad, Erich J; McCloskey, Michael; Constans, Joseph I

    2015-09-01

    Repeat violent injury is common among young urban men and is increasingly a focus of trauma center-based injury prevention efforts. Though understanding risk factors for repeat violent injury may be critical in designing such interventions, this knowledge is limited. This study aims to determine which criminal behaviors, both before and after the initial trauma, predict repeat violent trauma. Gun, violent, and drug crimes are expected to increase risk of subsequent violent injury among victims of violence. A case-control design examined trauma registry and publicly available criminal data for all male patients aged <40 years presenting for violent trauma between April 2006 and December 2011 (N=1,142) to the sole Level 1 trauma center in a city with high rates of violence. Logistic regression was used to determine criminal behaviors predictive of repeat violent injury. Data were obtained and analyzed between January 2013 and June 2014. Regarding crimes committed before the first injury, only drug crime (OR=5.32) predicted repeat violent trauma. With respect to crimes committed after the initial injury, illegal gun possession (OR=2.70) predicted repeat victimization. Initiating gun (OR=3.53) or drug crime (OR=5.12) was associated with increased risk. Prior drug involvement may identify young male victims of violence as at high risk of repeat violent injury. Gun carrying and initiating drug involvement after the initial injury may increase risk of repeat injury and may be important targets for interventions aimed at preventing repeat violent trauma. Published by Elsevier Inc.

  3. Collaborative study for the validation of alternative in vitro potency assays for human tetanus immunoglobulin.

    PubMed

    Gross, S; Janssen, S W J; de Vries, B; Terao, E; Daas, A; Buchheit, K-H

    2009-10-01

    The European Pharmacopoeia (Ph. Eur.) monograph Human tetanus immunoglobulin (0398) gives a clear outline of the in vivo assay to be performed to determine the potency of human tetanus immunoglobulins during their development. Furthermore, it states that an in vitro method shall be validated for the batch potency estimation. Since no further guidance is given on the in vitro assay, every control laboratory concerned is free to design and validate an in-house method. At the moment there is no agreed in vitro method available. The aim of this study was to validate and compare 2 alternative in vitro assays, i.e. an enzyme-linked immunoassay (EIA) and a toxoid inhibition assay (TIA), through an international collaborative study, in view of their eventual inclusion into the Ph. Eur.. The study was run in the framework of the Biological Standardisation Programme (BSP), under the aegis of the European Commission and the Council of Europe. The collaborative study reported here involved 21 laboratories (public and industry) from 15 countries. Initially, 3 samples with low, medium and high potencies were tested by EIA and TIA. Results showed good reproducibility and repeatability of the 2 in vitro methods. The correlation of the data with the in vivo potency assigned by the manufacturers however appeared initially poor for high potency samples. Thorough re-examination of the data showed that the in vivo potencies assigned by the manufacturers had to be corrected: one for potency loss at the time of in vitro testing and one because of a reporting error. After these corrections the values obtained by in vivo and in vitro methods were in close agreement. A supplementary collaborative work was carried out to validate the 2 methods for immunoglobulin products with high potencies. Eight laboratories (public and industry) took part in this additional study to test 3 samples with medium and high potencies by EIA and TIA. Results confirmed that the 2 alternative methods are comparable in terms of assay repeatability, precision and reproducibility. In all laboratories, both methods discriminated between the low, medium and high potency samples. Analysis of the data collected in this study showed a good correlation between EIA and TIA potency estimates as well as a close agreement between values obtained by in vitro and in vivo methods. The study demonstrated that EIA and TIA are suitable quality control methods for polyclonal human tetanus immunoglobulin, which can be standardised in a quality control laboratory using a quality assurance system. Consequently, the Ph. Eur. Group of Experts 6B on Human Blood and Blood products decided in April 2009 to include both methods as examples in the Ph. Eur. monograph 0398 on Human Tetanus immunoglobulin.

  4. An exploration of risk for recurrent falls in two geriatric care settings

    PubMed Central

    2013-01-01

    Background Fall events were examined in two distinct geriatric populations to identify factors associated with repeat fallers, and to examine whether patients who use gait aids, specifically a walker, were more likely to experience repeat falls. Each unit already had a generic program for falls prevention in place. Methods Secondary data analysis was conducted on information collected during the pilot testing of a new quality assurance Incident Reporting Tool between October 2006 and September 2008. The study settings included an in-patient geriatric rehabilitation unit (GRU) and a long stay veterans’ unit (LSVU) in a rehabilitation and long-stay hospital in Ontario. Participants were two hundred and twenty three individuals, aged 65 years or older on these two units, who experienced one or more fall incidents during the study period. Results Logistic regression analyses showed that on the GRU age was significantly associated with repeat falls. On the LSVU first falls in the morning or late evening were associated with repeat falling. Walker as a gait aid listed at time of first fall was not associated with repeat falls. Conclusions This study suggests that different intervention may be necessary in different geriatric settings to identify, for secondary prevention, certain individuals for which the generic programs prove inadequate. Information collection with a specific focus on the issue of repeat falls may be necessary for greater insight. PMID:24106879

  5. Generation and stabilization of Bell states via repeated projective measurements on a driven ancilla qubit

    NASA Astrophysics Data System (ADS)

    Magazzù, L.; Jaramillo, J. D.; Talkner, P.; Hänggi, P.

    2018-06-01

    A protocol is proposed to generate Bell states in two non-directly interacting qubits by means of repeated measurements of the state of a central ancilla connected to both qubits. An optimal measurement rate is found that minimizes the time to stably encode a Bell state in the target qubits, being of advantage in order to reduce detrimental effects from possible interactions with the environment. The quality of the entanglement is assessed in terms of the concurrence and the distance between the qubits state and the target Bell state is quantified by the fidelity.

  6. Analysis and discussion on the experimental data of electrolyte analyzer

    NASA Astrophysics Data System (ADS)

    Dong, XinYu; Jiang, JunJie; Liu, MengJun; Li, Weiwei

    2018-06-01

    In the subsequent verification of electrolyte analyzer, we found that the instrument can achieve good repeatability and stability in repeated measurements with a short period of time, in line with the requirements of verification regulation of linear error and cross contamination rate, but the phenomenon of large indication error is very common, the measurement results of different manufacturers have great difference, in order to find and solve this problem, help enterprises to improve quality of product, to obtain accurate and reliable measurement data, we conducted the experimental evaluation of electrolyte analyzer, and the data were analyzed by statistical analysis.

  7. Queen Quality and the Impact of Honey Bee Diseases on Queen Health: Potential for Interactions between Two Major Threats to Colony Health.

    PubMed

    Amiri, Esmaeil; Strand, Micheline K; Rueppell, Olav; Tarpy, David R

    2017-05-08

    Western honey bees, Apis mellifera , live in highly eusocial colonies that are each typically headed by a single queen. The queen is the sole reproductive female in a healthy colony, and because long-term colony survival depends on her ability to produce a large number of offspring, queen health is essential for colony success. Honey bees have recently been experiencing considerable declines in colony health. Among a number of biotic and abiotic factors known to impact colony health, disease and queen failure are repeatedly reported as important factors underlying colony losses. Surprisingly, there are relatively few studies on the relationship and interaction between honey bee diseases and queen quality. It is critical to understand the negative impacts of pests and pathogens on queen health, how queen problems might enable disease, and how both factors influence colony health. Here, we review the current literature on queen reproductive potential and the impacts of honey bee parasites and pathogens on queens. We conclude by highlighting gaps in our knowledge on the combination of disease and queen failure to provide a perspective and prioritize further research to mitigate disease, improve queen quality, and ensure colony health.

  8. Epilation for Minor Trachomatous Trichiasis: Four-Year Results of a Randomised Controlled Trial

    PubMed Central

    Habtamu, Esmael; Rajak, Saul N.; Tadesse, Zerihun; Wondie, Tariku; Zerihun, Mulat; Guadie, Birhan; Gebre, Teshome; Kello, Amir Bedri; Callahan, Kelly; Mabey, David C. W.; Khaw, Peng T.; Gilbert, Clare E.; Weiss, Helen A.; Emerson, Paul M.; Burton, Matthew J.

    2015-01-01

    Background Trachomatous trichiasis (TT) needs to be managed to reduce the risk of vision loss. The long-term impact of epilation (a common traditional practice of repeated plucking of lashes touching the eye) in preventing visual impairment and corneal opacity from TT is unknown. We conducted a randomized controlled trial of epilation versus surgery for the management of minor TT (fewer than six lashes touching the eye) in Ethiopia. Here we report the four-year outcome and the effect on vision and corneal opacity. Methodology/ Principal Findings 1300 individuals with minor TT were recruited and randomly assigned to quality trichiasis surgery or repeated epilation using high quality epilation forceps by a trained person with good near vision. Participants were examined six-monthly for two-years, and then at four-years after randomisation. At two-years all epilation arm participants were offered free surgery. At four-years 1151 (88.5%) were re-examined: 572 (88%) and 579 (89%) from epilation and surgery arms, respectively. At that time, 21.1% of the surgery arm participants had recurrent TT; 189/572 (33%) of the epilation arm had received surgery, while 383 (67%) declined surgery and had continued epilating (“epilation-only”). Among the epilation-only group, 207 (54.1%) fully controlled their TT, 166 (43.3%) had minor TT and 10 (2.6%) had major TT (>5 lashes). There were no differences between participants in the epilation-only, epilation-to-surgery and surgery arm participants in changes in visual acuity and corneal opacity between baseline and four-years. Conclusions/ Significance Most minor TT participants randomised to the epilation arm continued epilating and controlled their TT. Change in vision and corneal opacity was comparable between surgery and epilation-only participants. This suggests that good quality epilation with regular follow-up is a reasonable second-line alternative to surgery for minor TT for individuals who either decline surgery or do not have immediate access to surgical treatment. PMID:25768796

  9. Positional bias in variant calls against draft reference assemblies.

    PubMed

    Briskine, Roman V; Shimizu, Kentaro K

    2017-03-28

    Whole genome resequencing projects may implement variant calling using draft reference genomes assembled de novo from short-read libraries. Despite lower quality of such assemblies, they allowed researchers to extend a wide range of population genetic and genome-wide association analyses to non-model species. As the variant calling pipelines are complex and involve many software packages, it is important to understand inherent biases and limitations at each step of the analysis. In this article, we report a positional bias present in variant calling performed against draft reference assemblies constructed from de Bruijn or string overlap graphs. We assessed how frequently variants appeared at each position counted from ends of a contig or scaffold sequence, and discovered unexpectedly high number of variants at the positions related to the length of either k-mers or reads used for the assembly. We detected the bias in both publicly available draft assemblies from Assemblathon 2 competition as well as in the assemblies we generated from our simulated short-read data. Simulations confirmed that the bias causing variants are predominantly false positives induced by reads from spatially distant repeated sequences. The bias is particularly strong in contig assemblies. Scaffolding does not eliminate the bias but tends to mitigate it because of the changes in variants' relative positions and alterations in read alignments. The bias can be effectively reduced by filtering out the variants that reside in repetitive elements. Draft genome sequences generated by several popular assemblers appear to be susceptible to the positional bias potentially affecting many resequencing projects in non-model species. The bias is inherent to the assembly algorithms and arises from their particular handling of repeated sequences. It is recommended to reduce the bias by filtering especially if higher-quality genome assembly cannot be achieved. Our findings can help other researchers to improve the quality of their variant data sets and reduce artefactual findings in downstream analyses.

  10. Mapping of the DLQI scores to EQ-5D utility values using ordinal logistic regression.

    PubMed

    Ali, Faraz Mahmood; Kay, Richard; Finlay, Andrew Y; Piguet, Vincent; Kupfer, Joerg; Dalgard, Florence; Salek, M Sam

    2017-11-01

    The Dermatology Life Quality Index (DLQI) and the European Quality of Life-5 Dimension (EQ-5D) are separate measures that may be used to gather health-related quality of life (HRQoL) information from patients. The EQ-5D is a generic measure from which health utility estimates can be derived, whereas the DLQI is a specialty-specific measure to assess HRQoL. To reduce the burden of multiple measures being administered and to enable a more disease-specific calculation of health utility estimates, we explored an established mathematical technique known as ordinal logistic regression (OLR) to develop an appropriate model to map DLQI data to EQ-5D-based health utility estimates. Retrospective data from 4010 patients were randomly divided five times into two groups for the derivation and testing of the mapping model. Split-half cross-validation was utilized resulting in a total of ten ordinal logistic regression models for each of the five EQ-5D dimensions against age, sex, and all ten items of the DLQI. Using Monte Carlo simulation, predicted health utility estimates were derived and compared against those observed. This method was repeated for both OLR and a previously tested mapping methodology based on linear regression. The model was shown to be highly predictive and its repeated fitting demonstrated a stable model using OLR as well as linear regression. The mean differences between OLR-predicted health utility estimates and observed health utility estimates ranged from 0.0024 to 0.0239 across the ten modeling exercises, with an average overall difference of 0.0120 (a 1.6% underestimate, not of clinical importance). This modeling framework developed in this study will enable researchers to calculate EQ-5D health utility estimates from a specialty-specific study population, reducing patient and economic burden.

  11. A high quality assembly of the Nile Tilapia (Oreochromis niloticus) genome reveals the structure of two sex determination regions.

    PubMed

    Conte, Matthew A; Gammerdinger, William J; Bartie, Kerry L; Penman, David J; Kocher, Thomas D

    2017-05-02

    Tilapias are the second most farmed fishes in the world and a sustainable source of food. Like many other fish, tilapias are sexually dimorphic and sex is a commercially important trait in these fish. In this study, we developed a significantly improved assembly of the tilapia genome using the latest genome sequencing methods and show how it improves the characterization of two sex determination regions in two tilapia species. A homozygous clonal XX female Nile tilapia (Oreochromis niloticus) was sequenced to 44X coverage using Pacific Biosciences (PacBio) SMRT sequencing. Dozens of candidate de novo assemblies were generated and an optimal assembly (contig NG50 of 3.3Mbp) was selected using principal component analysis of likelihood scores calculated from several paired-end sequencing libraries. Comparison of the new assembly to the previous O. niloticus genome assembly reveals that recently duplicated portions of the genome are now well represented. The overall number of genes in the new assembly increased by 27.3%, including a 67% increase in pseudogenes. The new tilapia genome assembly correctly represents two recent vasa gene duplication events that have been verified with BAC sequencing. At total of 146Mbp of additional transposable element sequence are now assembled, a large proportion of which are recent insertions. Large centromeric satellite repeats are assembled and annotated in cichlid fish for the first time. Finally, the new assembly identifies the long-range structure of both a ~9Mbp XY sex determination region on LG1 in O. niloticus, and a ~50Mbp WZ sex determination region on LG3 in the related species O. aureus. This study highlights the use of long read sequencing to correctly assemble recent duplications and to characterize repeat-filled regions of the genome. The study serves as an example of the need for high quality genome assemblies and provides a framework for identifying sex determining genes in tilapia and related fish species.

  12. Nifty Nines and Repeating Decimals

    ERIC Educational Resources Information Center

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  13. Automated Neuropsychological Assessment Metrics: Repeated Assessment with Two Military Samples

    DTIC Science & Technology

    2011-01-01

    to ra- diation, high altitude, undersea conditions, and toxins ( 10,14,20 ). The putative advantages of ANAM4 (com- pared to other...repeated measures ANOVA. Separate analyses were performed for each of the ANAM subtests. Session was treated as a repeated variable. Huynh-Feldt epsilon

  14. Ligand binding by repeat proteins: natural and designed

    PubMed Central

    Grove, Tijana Z; Cortajarena, Aitziber L; Regan, Lynne

    2012-01-01

    Repeat proteins contain tandem arrays of small structural motifs. As a consequence of this architecture, they adopt non-globular, extended structures that present large, highly specific surfaces for ligand binding. Here we discuss recent advances toward understanding the functional role of this unique modular architecture. We showcase specific examples of natural repeat proteins interacting with diverse ligands and also present examples of designed repeat protein–ligand interactions. PMID:18602006

  15. Rapidly deployable emergency communication system

    DOEpatents

    Gladden, Charles A.; Parelman, Martin H.

    1979-01-01

    A highly versatile, highly portable emergency communication system which permits deployment in a very short time to cover both wide areas and distant isolated areas depending upon mission requirements. The system employs a plurality of lightweight, fully self-contained repeaters which are deployed within the mission area to provide communication between field teams, and between each field team and a mobile communication control center. Each repeater contains a microcomputer controller, the program for which may be changed from the control center by the transmission of digital data within the audible range (300-3,000 Hz). Repeaters are accessed by portable/mobile transceivers, other repeaters, and the control center through the transmission and recognition of digital data code words in the subaudible range.

  16. Seasonal differences in extinction and colonization drive occupancy dynamics of an imperilled amphibian.

    PubMed

    Randall, Lea A; Smith, Des H V; Jones, Breana L; Prescott, David R C; Moehrenschlager, Axel

    2015-01-01

    A detailed understanding of the population dynamics of many amphibian species is lacking despite concerns about declining amphibian biodiversity and abundance. This paper explores temporal patterns of occupancy and underlying extinction and colonization dynamics in a regionally imperiled amphibian species, the Northern leopard frog (Lithobates pipiens) in Alberta. Our study contributes to elucidating regional occupancy dynamics at northern latitudes, where climate extremes likely have a profound effect on seasonal occupancy. The primary advantage of our study is its wide geographic scale (60,000 km2) and the use of repeat visual surveys each spring and summer from 2009-2013. We find that occupancy varied more dramatically between seasons than years, with low spring and higher summer occupancy. Between spring and summer, colonization was high and extinction low; inversely, colonization was low and extinction high over the winter. The dynamics of extinction and colonization are complex, making conservation management challenging. Our results reveal that Northern leopard frog occupancy was constant over the last five years and thus there is no evidence of decline or recovery within our study area. Changes to equilibrium occupancy are most sensitive to increasing colonization in the spring or declining extinction in the summer. Therefore, conservation and management efforts should target actions that are likely to increase spring colonization; this could be achieved through translocations or improving the quality or access to breeding habitat. Because summer occupancy is already high, it may be difficult to improve further. Nevertheless, summer extinction could be reduced by predator control, increasing water quality or hydroperiod of wetlands, or increasing the quality or quantity of summer habitat.

  17. StaRProtein, A Web Server for Prediction of the Stability of Repeat Proteins

    PubMed Central

    Xu, Yongtao; Zhou, Xu; Huang, Meilan

    2015-01-01

    Repeat proteins have become increasingly important due to their capability to bind to almost any proteins and the potential as alternative therapy to monoclonal antibodies. In the past decade repeat proteins have been designed to mediate specific protein-protein interactions. The tetratricopeptide and ankyrin repeat proteins are two classes of helical repeat proteins that form different binding pockets to accommodate various partners. It is important to understand the factors that define folding and stability of repeat proteins in order to prioritize the most stable designed repeat proteins to further explore their potential binding affinities. Here we developed distance-dependant statistical potentials using two classes of alpha-helical repeat proteins, tetratricopeptide and ankyrin repeat proteins respectively, and evaluated their efficiency in predicting the stability of repeat proteins. We demonstrated that the repeat-specific statistical potentials based on these two classes of repeat proteins showed paramount accuracy compared with non-specific statistical potentials in: 1) discriminate correct vs. incorrect models 2) rank the stability of designed repeat proteins. In particular, the statistical scores correlate closely with the equilibrium unfolding free energies of repeat proteins and therefore would serve as a novel tool in quickly prioritizing the designed repeat proteins with high stability. StaRProtein web server was developed for predicting the stability of repeat proteins. PMID:25807112

  18. Monitoring urban air quality using a high-density network of low-cost sensor nodes in Oslo, Norway.

    NASA Astrophysics Data System (ADS)

    Castell, Nuria; Schneider, Philipp; Vogt, Matthias; Dauge, Franck R.; Lahoz, William; Bartonova, Alena

    2017-04-01

    Urban air quality represents a major public health burden and is a long-standing concern to citizens. Air pollution is associated with a range of diseases, symptoms and conditions that impair health and quality of life. In Oslo, traffic, especially exhaust from heavy-duty and private diesel vehicles and dust resuspension from studded tyres, together with wood burning in winter, are the main sources of pollution. Norway, as part of the European Economic Area, is obliged to comply with the European air quality regulations and ensure clean air. Despite this, Oslo has exceeded both the NO2 and PM10 thresholds for health protection defined in the Directive 2008/50/EC. The air quality in the Oslo area is continuously monitored in 12 compliance monitoring stations. These stations provide reliable and accurate data but their density is too low to provide a detailed spatial distribution of air quality. The emergence of low-cost nodes enables observations at high spatial resolution, providing the opportunity to enhance existing monitoring systems. However, the data generated by these nodes is significantly less accurate and precise than the data provided by reference equipment. We have conducted an evaluation of low-cost nodes to monitor NO2 and PM10, comparing the data collected with low-cost nodes against CEN (European Standardization Organization) reference analysers. During January and March 2016, a network of 24 nodes was deployed in Oslo. During January, high NO2 levels were observed for several days in a row coinciding with the formation of a thermal inversion. During March, we observed an episode with high PM10 levels due to road dust resuspension. Our results show that there is a major technical challenge associated with current commercial low-cost sensors, regarding the sensor robustness and measurement repeatability. Despite this, low-cost sensor nodes are able to reproduce the NO2 and PM10 variability. The data from the sensors was employed to generate detailed NO2 and PM10 air quality maps using a data fusion technique. This way we were able to offer localized air quality information for the city of Oslo. The outlook for commercial low-cost sensors is promising, and our results show that currently some sensors are already capable of providing coarse information about air quality, indicating if the air quality is good, moderate or if the air is heavily polluted. This type of information could be suitable for applications that aim to raise awareness, or engage the community by monitoring local air quality, as such applications do not require the same accuracy as scientific or regulatory monitoring.

  19. Relationship of cooked rice nutritionally-important starch fractions with other physicochemical properties.

    USDA-ARS?s Scientific Manuscript database

    Sixteen rice cultivars representing 5 cytosine-thymine repeat (CTn) microsatellite genetic marker groups were analyzed for their cooked rice nutritionally-important starch fractions (rapidly digestible, slowly digestible, and resistant starch), basic grain quality indices (apparent amylose, crude pr...

  20. Improved rice method for determining theoretical maximum density of asphalt paving mixtures

    DOT National Transportation Integrated Search

    1992-05-01

    Rice method (ASTM D2041 ) is used for determining the theoretical maximum specific gravity of asphalt paving mixtures which is one of the main test parameters used for mix design and construction quality control. The repeatability and reproducibility...

  1. On the Validity of Repeated Assessments in the UMAT, a High-Stakes Admissions Test

    ERIC Educational Resources Information Center

    Andrich, David; Styles, Irene; Mercer, Annette; Puddey, Ian B.

    2017-01-01

    The possibility that the validity of assessment is compromised by repeated sittings of highly competitive and high profile selection tests has been documented and is of concern to stake-holders. An illustrative example is the Undergraduate Medicine and Health Sciences Admission Test (UMAT) used by some medical and dental courses in Australia and…

  2. Nimbus 7 Solar Backscatter Ultraviolet (SBUV) spectral scan solar irradiance and Earth radiance product user's guide

    NASA Technical Reports Server (NTRS)

    Schlesinger, Barry M.; Cebula, Richard P.; Heath, Donald F.; Fleig, Albert J.

    1988-01-01

    The archived tape products from the spectral scan mode measurements of solar irradiance (SUNC tapes) and Earth radiance (EARTH tapes) by the Solar Backscatter UV (SBUV) instrument aboard Nimbus 7 are described. Incoming radiation from 160 to 400 nm is measured at intervals of 0.2 nm. The scan-to-scan repeatability of the solar irradiance measurements ranges from approximately 0.5 to 1 percent longward of 280 nm, to 2 percent around 210 nm and 4 percent near 175 nm. The repeatability of the Earth radiance values ranges from 2 to 3 percent at longer wavelengths and low zenith angles to 10 percent at shorter wavelengths and high zenith angles. The tape formats are described in detail, including file structure and contents of each type of record. Catalogs of the tapes and the time period covered are provided, along with lists of the days lacking solar irradiance measurements and the days dedicated to Earth radiance measurements. The method for production of the tapes is outlined and quality control measures are described. How radiances and irradiances are derived from the raw counts, the corrections for changes in instrument sensitivity, and related uncertainties are discussed.

  3. Investigation of some selected strategies for multi-GNSS instantaneous RTK positioning

    NASA Astrophysics Data System (ADS)

    Paziewski, Jacek; Wielgosz, Pawel

    2017-01-01

    It is clear that we can benefit from multi-constellation GNSS in precise relative positioning. On the other hand, it is still an open problem how to combine multi-GNSS signals in a single functional model. This study presents methodology and quality assessment of selected methods allowing for multi-GNSS observations combining in relative kinematic positioning using baselines up to tens of kilometers. In specific, this paper characterizes loose and tight integration strategies applied to the ionosphere and troposphere weighted model. Performance assessment of the established strategies was based on the analyses of the integer ambiguity resolution and rover coordinates' repeatability obtained in the medium range instantaneous RTK positioning with the use of full constellation dual frequency GPS and Galileo signals. Since full constellation of Galileo satellites is not yet available, the observational data were obtained from a hardware GNSS signal simulator using regular geodetic GNSS receivers. The results indicate on similar and high performance of the loose, and tight integration with calibrated receiver ISBs strategies. These approaches have undeniable advantage over single system positioning in terms of reliability of the integer ambiguity resolution as well as rover coordinate repeatability.

  4. A repeated short educational intervention improves asthma control and quality of life.

    PubMed

    Plaza, Vicente; Peiró, Meritxell; Torrejón, Montserrat; Fletcher, Monica; López-Viña, Antolín; Ignacio, José María; Quintano, José Antonio; Bardagí, Santiago; Gich, Ignasi

    2015-11-01

    We assessed the effectiveness of an asthma educational programme based on a repeated short intervention (AEP-RSI) to improve asthma control (symptom control and future risk) and quality of life. A total of 230 adults with mild-to-moderate persistent uncontrolled asthma participated in a 1-year cluster randomised controlled multicentre study. The AEP-RSI was given in four face-to-face sessions at 3-month intervals, and included administration of a written personalised action plan and training on inhaler technique. Centres were randomised to the AEP-RSI (intervention) group or usual clinical practice group. Specialised centres using a standard educational programme were the gold standard group. A significant improvement in the Asthma Control Test score was observed in all three groups (p<0.001), but improvements were higher in the intervention and gold standard groups than in the usual clinical practice group (p=0.042), which also showed fewer exacerbations (mean±sd; 1.20±2.02 and 0.56±1.5 versus 2.04±2.72, respectively) and greater increases in the Mini Asthma Quality of Life Questionnaire scores (0.95±1.04 and 0.89±0.84 versus 0.52±0.97, respectively). The AEP-RSI was effective in improving asthma symptom control, future risk and quality of life. Copyright ©ERS 2015.

  5. Craniofacial and upper airway morphology in pediatric sleep-disordered breathing and changes in quality of life with rapid maxillary expansion.

    PubMed

    Katyal, Vandana; Pamula, Yvonne; Daynes, Cathal N; Martin, James; Dreyer, Craig W; Kennedy, Declan; Sampson, Wayne J

    2013-12-01

    The association between pediatric sleep-disordered breathing caused by upper airway obstruction and craniofacial morphology is poorly understood and contradictory. The aims of this study were to evaluate the prevalence of children at risk for sleep-disordered breathing, as identified in an orthodontic setting by validated screening questionnaires, and to examine associations with their craniofacial and upper airway morphologies. A further aim was to assess the change in quality of life related to sleep-disordered breathing for affected children undergoing rapid maxillary expansion to correct a palatal crossbite or widen a narrow maxilla. A prospective case-control study with children between 8 and 17 years of age (n = 81) at an orthodontic clinic was undertaken. The subjects were grouped as high risk or low risk for sleep-disordered breathing based on the scores from a validated 22-item Pediatric Sleep Questionnaire and the Obstructive Sleep Apnea-18 Quality of Life Questionnaire. Variables pertaining to a screening clinical examination, cephalometric assessment, and dental cast analysis were tested for differences between the 2 groups at baseline. Ten children who underwent rapid maxillary expansion were followed longitudinally until removal of the appliance approximately 9 months later with a repeated Obstructive Sleep Apnea-18 Quality of Life Questionnaire. All data were collected blinded to the questionnaire results. The frequency of palatal crossbite involving at least 3 teeth was significantly higher in the high-risk group at 68.2%, compared with the low-risk group at 23.2% (P <0.0001). Average quality of life scores in the high-risk group indicated reduced quality of life related to sleep-disordered breathing by 16% compared with children in the low-risk group at baseline (P <0.0001). Cephalometrically, mean inferior airway space, posterior nasal spine to adenoidal mass distance, and adenoidal mass to soft palate distance were reduced in the high-risk group compared with the low-risk group by 1.87 mm (P <0.03), 2.82 mm (P <0.04), and 2.13 mm (P <0.03), respectively. The mean maxillary intercanine, maxillary interfirst premolar, maxillary interfirst molar, mandibular intercanine, and mandibular interfirst premolar widths were reduced in the high-risk group compared with the low-risk group by 4.22 mm (P <0.0001), 3.92 mm (P <0.0001), 4.24 mm (P <0.0001), 1.50 mm (P <0.01), and 1.84 mm (P <0.01), respectively. Children treated with rapid maxillary expansion showed an average improvement of 14% in quality of life scores in the high-risk group compared with the low-risk group, which showed a slight worsening in quality of life related to sleep-disordered breathing by an average of 1% (P <0.04), normalizing the quality of life scores in the high-risk children to the baseline scores compared with the low-risk group. Children at high risk for sleep-disordered breathing are characterized by reduced quality of life, reduced nasopharyngeal and oropharyngeal sagittal dimensions, palatal crossbite, and reduced dentoalveolar transverse widths in the maxillary and mandibular arches. No sagittal or vertical craniofacial skeletal cephalometric predictors were identified for children at high risk for sleep-disordered breathing. In the short term, rapid maxillary expansion might aid in improvement of the quality of life for children with a narrow maxilla in the milder end of the sleep-disordered breathing spectrum. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  6. Using Creative Problem Solving (TRIZ) in Improving the Quality of Hospital Services

    PubMed Central

    LariSemnani, Behrouz; Far, Rafat Mohebbi; Shalipoor, Elham; Mohseni, Mohammad

    2015-01-01

    TRIZ is an initiative and SERVQUAL is a structured methodology for quality improvement. Using these tools, inventive problem solving can be applied for quality improvement, and the highest quality can be reached using creative quality improvement methodology. The present study seeks to determine the priority of quality aspects of services provided for patients in the hospital as well as how TRIZ can help in improving the quality of those services. This Study is an applied research which used a dynamic qualitative descriptive survey method during year 2011. Statistical population includes every patient who visited in one of the University Hospitals from March 2011. There existed a big gap between patients’ expectations from what seemingly is seen (the design of the hospital) and timely provision of services with their perceptions. Also, quality aspects of services were prioritized as follows: keeping the appearance of hospital (the design), accountability, assurance, credibility and having empathy. Thus, the only thing which mattered most for all staff and managers of studied hospital was the appearance of hospital as well as its staff look. This can grasp a high percentage of patients’ satisfaction. By referring to contradiction matrix, the most important principles of TRIZ model were related to tangible factors including principles No. 13 (discarding and recovering), 25 (self-service), 35 (parameter changes), and 2 (taking out). Furthermore, in addition to these four principles, principle No. 24 (intermediary) was repeated most among the others. By utilizing TRIZ, hospital problems can be examined with a more open view, Go beyond The conceptual framework of the organization and responded more quickly to patients ’ needs. PMID:25560360

  7. Assessing data quality and the variability of source data verification auditing methods in clinical research settings.

    PubMed

    Houston, Lauren; Probst, Yasmine; Martin, Allison

    2018-05-18

    Data audits within clinical settings are extensively used as a major strategy to identify errors, monitor study operations and ensure high-quality data. However, clinical trial guidelines are non-specific in regards to recommended frequency, timing and nature of data audits. The absence of a well-defined data quality definition and method to measure error undermines the reliability of data quality assessment. This review aimed to assess the variability of source data verification (SDV) auditing methods to monitor data quality in a clinical research setting. The scientific databases MEDLINE, Scopus and Science Direct were searched for English language publications, with no date limits applied. Studies were considered if they included data from a clinical trial or clinical research setting and measured and/or reported data quality using a SDV auditing method. In total 15 publications were included. The nature and extent of SDV audit methods in the articles varied widely, depending upon the complexity of the source document, type of study, variables measured (primary or secondary), data audit proportion (3-100%) and collection frequency (6-24 months). Methods for coding, classifying and calculating error were also inconsistent. Transcription errors and inexperienced personnel were the main source of reported error. Repeated SDV audits using the same dataset demonstrated ∼40% improvement in data accuracy and completeness over time. No description was given in regards to what determines poor data quality in clinical trials. A wide range of SDV auditing methods are reported in the published literature though no uniform SDV auditing method could be determined for "best practice" in clinical trials. Published audit methodology articles are warranted for the development of a standardised SDV auditing method to monitor data quality in clinical research settings. Copyright © 2018. Published by Elsevier Inc.

  8. Expansion of 50 CAG/CTG repeats excluded in schizophrenia by application of a highly efficient approach using repeat expansion detection and a PCR screening set

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowen, T.; Guy, C.; Speight, G.

    Studies of the transmission of schizophrenia in families with affected members in several generations have suggested that an expanded trinucleotide repeat mechanism may contribute to the genetic inheritance of this disorder. Using repeat expansion detection (RED), we and others have previously found that the distribution of CAG/CTG repeat size is larger in patients with schizophrenia than in controls. In an attempt to identify the specific expanded CAG/CTG locus or loci associated with schizophrenia, we have now used an approach based on a CAG/CTG PCR screening set combined with RED data. This has allowed us to minimize genotyping while excluding 43more » polymorphic autosomal loci and 7 X-chromosomal loci from the screening set as candidates for expansion in schizophrenia with a very high degree of confidence. 18 refs., 1 tab.« less

  9. Controls of repeating earthquakes' location from a- and b- values imaging

    NASA Astrophysics Data System (ADS)

    Chen, K. H.; Kawamura, M.

    2017-12-01

    The locations where creeping and locked fault areas abut have commonly found to be delineated by the foci of small repeating earthquakes (REs). REs not only represent the finer structure of high creep-rate location, they also function as fault slip-rate indicators. Knowledge of the expected location of REs therefore, is crucial for fault deformation monitoring and assessment of earthquake potential. However, a precise description of factors determining REs locations is lacking. To explore where earthquakes tend to recur, we statistically investigated repeating earthquake catalogs and background seismicity from different regions including six fault segments in California and Taiwan. We show that the location of repeating earthquakes can be mapped using the spatial distribution of the seismic a- and b-values obtained from the background seismicity. Molchan's error diagram statistically confirmed that repeating earthquakes occur within areas with high a-values (2.8-3.8) and high b-values (0.9-1.1) on both strike-slip and thrust fault segments. However, no significant association held true for fault segments with more complicated geometry or for wider areas with a complex fault network. The productivity of small earthquakes responsible for high a- and b-values may thus be the most important factor controlling the location of repeating earthquakes. We hypothesize that, given that the deformation conditions within a fault zone are suitable for a planar fault plane, the location of repeating earthquakes can be best described by a-value 3 and b-value 1. This feature of a- and b-values may be useful for foresee the location of REs for measuring creep rate at depth. Further investigation of REs-rich areas may allow testing of this hypothesis.

  10. A Complete and Accurate Ab Initio Repeat Finding Algorithm.

    PubMed

    Lian, Shuaibin; Chen, Xinwu; Wang, Peng; Zhang, Xiaoli; Dai, Xianhua

    2016-03-01

    It has become clear that repetitive sequences have played multiple roles in eukaryotic genome evolution including increasing genetic diversity through mutation, changes in gene expression and facilitating generation of novel genes. However, identification of repetitive elements can be difficult in the ab initio manner. Currently, some classical ab initio tools of finding repeats have already presented and compared. The completeness and accuracy of detecting repeats of them are little pool. To this end, we proposed a new ab initio repeat finding tool, named HashRepeatFinder, which is based on hash index and word counting. Furthermore, we assessed the performances of HashRepeatFinder with other two famous tools, such as RepeatScout and Repeatfinder, in human genome data hg19. The results indicated the following three conclusions: (1) The completeness of HashRepeatFinder is the best one among these three compared tools in almost all chromosomes, especially in chr9 (8 times of RepeatScout, 10 times of Repeatfinder); (2) in terms of detecting large repeats, HashRepeatFinder also performed best in all chromosomes, especially in chr3 (24 times of RepeatScout and 250 times of Repeatfinder) and chr19 (12 times of RepeatScout and 60 times of Repeatfinder); (3) in terms of accuracy, HashRepeatFinder can merge the abundant repeats with high accuracy.

  11. A new estimator for VLBI baseline length repeatability

    NASA Astrophysics Data System (ADS)

    Titov, O.

    2009-11-01

    The goal of this paper is to introduce a more effective technique to approximate for the “repeatability-baseline length” relationship that is used to evaluate the quality of geodetic VLBI results. Traditionally, this relationship is approximated by a quadratic function of baseline length over all baselines. The new model incorporates the mean number of observed group delays of the reference radio sources (i.e. estimated as global parameters) used in the estimation of each baseline. It is shown that the new method provides a better approximation of the “repeatability-baseline length” relationship than the traditional model. Further development of the new approach comes down to modeling the repeatability as a function of two parameters: baseline length and baseline slewing rate. Within the framework of this new approach the station vertical and horizontal uncertainties can be treated as a function of baseline length. While the previous relationship indicated that the station vertical uncertainties are generally 4-5 times larger than the horizontal uncertainties, the vertical uncertainties as determined by the new method are only larger by a factor of 1.44 over all baseline lengths.

  12. "Repeating Events" as Estimator of Location Precision: The China National Seismograph Network

    NASA Astrophysics Data System (ADS)

    Jiang, Changsheng; Wu, Zhongliang; Li, Yutong; Ma, Tengfei

    2014-03-01

    "Repeating earthquakes" identified by waveform cross-correlation, with inter-event separation of no more than 1 km, can be used for assessment of location precision. Assuming that the network-measured apparent inter-epicenter distance X of the "repeating doublets" indicates the location precision, we estimated the regionalized location quality of the China National Seismograph Network by comparing the "repeating events" in and around China by S chaff and R ichards (Science 303: 1176-1178, 2004; J Geophys Res 116: B03309, 2011) and the monthly catalogue of the China Earthquake Networks Center. The comparison shows that the average X value of the China National Seismograph Network is approximately 10 km. The mis-location is larger for the Tibetan Plateau, west and north of Xinjiang, and east of Inner Mongolia, as indicated by larger X values. Mis-location is correlated with the completeness magnitude of the earthquake catalogue. Using the data from the Beijing Capital Circle Region, the dependence of the mis-location on the distribution of seismic stations can be further confirmed.

  13. Engineering customized TALE nucleases (TALENs) and TALE transcription factors by fast ligation-based automatable solid-phase high-throughput (FLASH) assembly.

    PubMed

    Reyon, Deepak; Maeder, Morgan L; Khayter, Cyd; Tsai, Shengdar Q; Foley, Jonathan E; Sander, Jeffry D; Joung, J Keith

    2013-07-01

    Customized DNA-binding domains made using transcription activator-like effector (TALE) repeats are rapidly growing in importance as widely applicable research tools. TALE nucleases (TALENs), composed of an engineered array of TALE repeats fused to the FokI nuclease domain, have been used successfully for directed genome editing in various organisms and cell types. TALE transcription factors (TALE-TFs), consisting of engineered TALE repeat arrays linked to a transcriptional regulatory domain, have been used to up- or downregulate expression of endogenous genes in human cells and plants. This unit describes a detailed protocol for the recently described fast ligation-based automatable solid-phase high-throughput (FLASH) assembly method. FLASH enables automated high-throughput construction of engineered TALE repeats using an automated liquid handling robot or manually using a multichannel pipet. Using the automated approach, a single researcher can construct up to 96 DNA fragments encoding TALE repeat arrays of various lengths in a single day, and then clone these to construct sequence-verified TALEN or TALE-TF expression plasmids in a week or less. Plasmids required for FLASH are available by request from the Joung lab (http://eGenome.org). This unit also describes improvements to the Zinc Finger and TALE Targeter (ZiFiT Targeter) web server (http://ZiFiT.partners.org) that facilitate the design and construction of FLASH TALE repeat arrays in high throughput. © 2013 by John Wiley & Sons, Inc.

  14. Engineering Customized TALE Nucleases (TALENs) and TALE Transcription Factors by Fast Ligation-based Automatable Solid-phase High-throughput (FLASH) Assembly

    PubMed Central

    Reyon, Deepak; Maeder, Morgan L.; Khayter, Cyd; Tsai, Shengdar Q.; Foley, Jonathan E.; Sander, Jeffry D.; Joung, J. Keith

    2013-01-01

    Customized DNA-binding domains made using Transcription Activator-Like Effector (TALE) repeats are rapidly growing in importance as widely applicable research tools. TALE nucleases (TALENs), composed of an engineered array of TALE repeats fused to the FokI nuclease domain, have been used successfully for directed genome editing in multiple different organisms and cell types. TALE transcription factors (TALE-TFs), consisting of engineered TALE repeat arrays linked to a transcriptional regulatory domain, have been used to up- or down-regulate expression of endogenous genes in human cells and plants. Here we describe a detailed protocol for practicing the recently described Fast Ligation-based Automatable Solid-phase High-throughput (FLASH) assembly method. FLASH enables automated high-throughput construction of engineered TALE repeats using an automated liquid handling robot or manually using a multi-channel pipet. With the automated version of FLASH, a single researcher can construct up to 96 DNA fragments encoding various length TALE repeat arrays in one day and then clone these to construct sequence-verified TALEN or TALE-TF expression plasmids in one week or less. Plas-mids required to practice FLASH are available by request from the Joung Lab (http://www.jounglab.org/). We also describe here improvements to the Zinc Finger and TALE Targeter (ZiFiT Targeter) webserver (http://ZiFiTBeta.partners.org) that facilitate the design and construction of FLASH TALE repeat arrays in high-throughput. PMID:23821439

  15. High-speed quantum networking by ship

    NASA Astrophysics Data System (ADS)

    Devitt, Simon J.; Greentree, Andrew D.; Stephens, Ashley M.; van Meter, Rodney

    2016-11-01

    Networked entanglement is an essential component for a plethora of quantum computation and communication protocols. Direct transmission of quantum signals over long distances is prevented by fibre attenuation and the no-cloning theorem, motivating the development of quantum repeaters, designed to purify entanglement, extending its range. Quantum repeaters have been demonstrated over short distances, but error-corrected, global repeater networks with high bandwidth require new technology. Here we show that error corrected quantum memories installed in cargo containers and carried by ship can provide a exible connection between local networks, enabling low-latency, high-fidelity quantum communication across global distances at higher bandwidths than previously proposed. With demonstrations of technology with sufficient fidelity to enable topological error-correction, implementation of the quantum memories is within reach, and bandwidth increases with improvements in fabrication. Our approach to quantum networking avoids technological restrictions of repeater deployment, providing an alternate path to a worldwide Quantum Internet.

  16. High-speed quantum networking by ship

    PubMed Central

    Devitt, Simon J.; Greentree, Andrew D.; Stephens, Ashley M.; Van Meter, Rodney

    2016-01-01

    Networked entanglement is an essential component for a plethora of quantum computation and communication protocols. Direct transmission of quantum signals over long distances is prevented by fibre attenuation and the no-cloning theorem, motivating the development of quantum repeaters, designed to purify entanglement, extending its range. Quantum repeaters have been demonstrated over short distances, but error-corrected, global repeater networks with high bandwidth require new technology. Here we show that error corrected quantum memories installed in cargo containers and carried by ship can provide a exible connection between local networks, enabling low-latency, high-fidelity quantum communication across global distances at higher bandwidths than previously proposed. With demonstrations of technology with sufficient fidelity to enable topological error-correction, implementation of the quantum memories is within reach, and bandwidth increases with improvements in fabrication. Our approach to quantum networking avoids technological restrictions of repeater deployment, providing an alternate path to a worldwide Quantum Internet. PMID:27805001

  17. High-speed quantum networking by ship.

    PubMed

    Devitt, Simon J; Greentree, Andrew D; Stephens, Ashley M; Van Meter, Rodney

    2016-11-02

    Networked entanglement is an essential component for a plethora of quantum computation and communication protocols. Direct transmission of quantum signals over long distances is prevented by fibre attenuation and the no-cloning theorem, motivating the development of quantum repeaters, designed to purify entanglement, extending its range. Quantum repeaters have been demonstrated over short distances, but error-corrected, global repeater networks with high bandwidth require new technology. Here we show that error corrected quantum memories installed in cargo containers and carried by ship can provide a exible connection between local networks, enabling low-latency, high-fidelity quantum communication across global distances at higher bandwidths than previously proposed. With demonstrations of technology with sufficient fidelity to enable topological error-correction, implementation of the quantum memories is within reach, and bandwidth increases with improvements in fabrication. Our approach to quantum networking avoids technological restrictions of repeater deployment, providing an alternate path to a worldwide Quantum Internet.

  18. Investigation of a Quadruplex-Forming Repeat Sequence Highly Enriched in Xanthomonas and Nostoc sp.

    PubMed

    Rehm, Charlotte; Wurmthaler, Lena A; Li, Yuanhao; Frickey, Tancred; Hartig, Jörg S

    2015-01-01

    In prokaryotes simple sequence repeats (SSRs) with unit sizes of 1-5 nucleotides (nt) are causative for phase and antigenic variation. Although an increased abundance of heptameric repeats was noticed in bacteria, reports about SSRs of 6-9 nt are rare. In particular G-rich repeat sequences with the propensity to fold into G-quadruplex (G4) structures have received little attention. In silico analysis of prokaryotic genomes show putative G4 forming sequences to be abundant. This report focuses on a surprisingly enriched G-rich repeat of the type GGGNATC in Xanthomonas and cyanobacteria such as Nostoc. We studied in detail the genomes of Xanthomonas campestris pv. campestris ATCC 33913 (Xcc), Xanthomonas axonopodis pv. citri str. 306 (Xac), and Nostoc sp. strain PCC7120 (Ana). In all three organisms repeats are spread all over the genome with an over-representation in non-coding regions. Extensive variation of the number of repetitive units was observed with repeat numbers ranging from two up to 26 units. However a clear preference for four units was detected. The strong bias for four units coincides with the requirement of four consecutive G-tracts for G4 formation. Evidence for G4 formation of the consensus repeat sequences was found in biophysical studies utilizing CD spectroscopy. The G-rich repeats are preferably located between aligned open reading frames (ORFs) and are under-represented in coding regions or between divergent ORFs. The G-rich repeats are preferentially located within a distance of 50 bp upstream of an ORF on the anti-sense strand or within 50 bp from the stop codon on the sense strand. Analysis of whole transcriptome sequence data showed that the majority of repeat sequences are transcribed. The genetic loci in the vicinity of repeat regions show increased genomic stability. In conclusion, we introduce and characterize a special class of highly abundant and wide-spread quadruplex-forming repeat sequences in bacteria.

  19. Investigation of a Quadruplex-Forming Repeat Sequence Highly Enriched in Xanthomonas and Nostoc sp.

    PubMed Central

    Rehm, Charlotte; Wurmthaler, Lena A.; Li, Yuanhao; Frickey, Tancred; Hartig, Jörg S.

    2015-01-01

    In prokaryotes simple sequence repeats (SSRs) with unit sizes of 1–5 nucleotides (nt) are causative for phase and antigenic variation. Although an increased abundance of heptameric repeats was noticed in bacteria, reports about SSRs of 6–9 nt are rare. In particular G-rich repeat sequences with the propensity to fold into G-quadruplex (G4) structures have received little attention. In silico analysis of prokaryotic genomes show putative G4 forming sequences to be abundant. This report focuses on a surprisingly enriched G-rich repeat of the type GGGNATC in Xanthomonas and cyanobacteria such as Nostoc. We studied in detail the genomes of Xanthomonas campestris pv. campestris ATCC 33913 (Xcc), Xanthomonas axonopodis pv. citri str. 306 (Xac), and Nostoc sp. strain PCC7120 (Ana). In all three organisms repeats are spread all over the genome with an over-representation in non-coding regions. Extensive variation of the number of repetitive units was observed with repeat numbers ranging from two up to 26 units. However a clear preference for four units was detected. The strong bias for four units coincides with the requirement of four consecutive G-tracts for G4 formation. Evidence for G4 formation of the consensus repeat sequences was found in biophysical studies utilizing CD spectroscopy. The G-rich repeats are preferably located between aligned open reading frames (ORFs) and are under-represented in coding regions or between divergent ORFs. The G-rich repeats are preferentially located within a distance of 50 bp upstream of an ORF on the anti-sense strand or within 50 bp from the stop codon on the sense strand. Analysis of whole transcriptome sequence data showed that the majority of repeat sequences are transcribed. The genetic loci in the vicinity of repeat regions show increased genomic stability. In conclusion, we introduce and characterize a special class of highly abundant and wide-spread quadruplex-forming repeat sequences in bacteria. PMID:26695179

  20. Recognition Imaging of Acetylated Chromatin Using a DNA Aptamer

    PubMed Central

    Lin, Liyun; Fu, Qiang; Williams, Berea A.R.; Azzaz, Abdelhamid M.; Shogren-Knaak, Michael A.; Chaput, John C.; Lindsay, Stuart

    2009-01-01

    Histone acetylation plays an important role in the regulation of gene expression. A DNA aptamer generated by in vitro selection to be highly specific for histone H4 protein acetylated at lysine 16 was used as a recognition element for atomic force microscopy-based recognition imaging of synthetic nucleosomal arrays with precisely controlled acetylation. The aptamer proved to be reasonably specific at recognizing acetylated histones, with recognition efficiencies of 60% on-target and 12% off-target. Though this selectivity is much poorer than the >2000:1 equilibrium specificity of the aptamer, it is a large improvement on the performance of a ChIP-quality antibody, which is not selective at all in this application, and it should permit high-fidelity recognition with repeated imaging. The ability to image the precise location of posttranslational modifications may permit nanometer-scale investigation of their effect on chromatin structure. PMID:19751687

  1. Non local means denoising in photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Siregar, Syahril; Nagaoka, Ryo; Haq, Israr Ul; Saijo, Yoshifumi

    2018-07-01

    Photoacoustic (PA) imaging has the ability to visualize human organs with high spatial resolution and high contrast. Like digital images, PA images are contaminated with random noise due to some parameters. The band-pass filter does not effectively remove the noise because noise is randomly distributed in the bandwidth frequency. We present noise removal method in PA images by using non local means denoising (NLMD) method. The NLMD can be used if there are similarities or redundancies in the image. PA images contain of blood vessel which repeating on the small patch. The method was tested on PA images of carbon nanotubes in micropipe, in vivo mice brain and in vivo mice ear. We estimated the suggested input parameters of NLMD, so it can be automatically applied after scanning the image in PA imaging system. Our results declared that the NLMD enhanced the image quality of PA images.

  2. Fabrication of polydimethylsiloxane (PDMS) nanofluidic chips with controllable channel size and spacing.

    PubMed

    Peng, Ran; Li, Dongqing

    2016-10-07

    The ability to create reproducible and inexpensive nanofluidic chips is essential to the fundamental research and applications of nanofluidics. This paper presents a novel and cost-effective method for fabricating a single nanochannel or multiple nanochannels in PDMS chips with controllable channel size and spacing. Single nanocracks or nanocrack arrays, positioned by artificial defects, are first generated on a polystyrene surface with controllable size and spacing by a solvent-induced method. Two sets of optimal working parameters are developed to replicate the nanocracks onto the polymer layers to form the nanochannel molds. The nanochannel molds are used to make the bi-layer PDMS microchannel-nanochannel chips by simple soft lithography. An alignment system is developed for bonding the nanofluidic chips under an optical microscope. Using this method, high quality PDMS nanofluidic chips with a single nanochannel or multiple nanochannels of sub-100 nm width and height and centimeter length can be obtained with high repeatability.

  3. Genome Sequencing and Assembly by Long Reads in Plants

    PubMed Central

    Li, Changsheng; Lin, Feng; An, Dong; Huang, Ruidong

    2017-01-01

    Plant genomes generated by Sanger and Next Generation Sequencing (NGS) have provided insight into species diversity and evolution. However, Sanger sequencing is limited in its applications due to high cost, labor intensity, and low throughput, while NGS reads are too short to resolve abundant repeats and polyploidy, leading to incomplete or ambiguous assemblies. The advent and improvement of long-read sequencing by Third Generation Sequencing (TGS) methods such as PacBio and Nanopore have shown promise in producing high-quality assemblies for complex genomes. Here, we review the development of sequencing, introducing the application as well as considerations of experimental design in TGS of plant genomes. We also introduce recent revolutionary scaffolding technologies including BioNano, Hi-C, and 10× Genomics. We expect that the informative guidance for genome sequencing and assembly by long reads will benefit the initiation of scientists’ projects. PMID:29283420

  4. What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?

    PubMed

    Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E

    2018-03-01

    Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values <40 mg/dL, 58% of deleted values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values <40 mg/dL could decrease reported rates of severe hypoglycemia by as much as 40%. This project demonstrates that operators are frequently able to identify POC BG values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.

  5. Education for patients with chronic kidney disease in Taiwan: a prospective repeated measures study.

    PubMed

    Yen, Miaofen; Huang, Jeng-Jong; Teng, Hsiu-Lan

    2008-11-01

    To investigate the physical, knowledge and quality of life outcomes of an educational intervention for patients with early stage chronic kidney disease. A comprehensive predialysis education care team can be effective in slowing the progression of chronic kidney disease. A single group repeated measures design was used to evaluate the effects of the intervention. Participants were recruited through health department community health screen data banks. A predialysis, team-delivered educational intervention covering renal function health care, dietary management of renal function and the effects of Chinese herb medication on renal function was designed and implemented. Data were collected at baseline, six and 12 months. Study outcomes included physical indicators, knowledge (renal function protection, use of Chinese herbs and renal function and diet) and quality of life. Data were analysed using repeated measure anova to test for change over time in outcome variables. Sixty-six persons participated in this study. The predialysis educational intervention showed significant differences at the three time points in overall knowledge scores, waist-hip ratio, body mass index and global health status. Knowledge measures increased at month 6 and decreased at month 12. The primary indicator of renal function, glomerular filtration rate, remained stable throughout the 12 months of follow-up, despite the relatively older mean age of study participants. A predialysis education care team can provide effective disease-specific knowledge and may help retard deterioration of renal function in persons with early-stage chronic kidney disease. The intervention dose may need to be repeated every six months to maintain knowledge effects. A predialysis educational program with disease-specific knowledge and information is feasible and may provide positive outcomes for patients. Topics on the uses of Chinese herbs should be included for people who are likely to use alternative therapies.

  6. A mobile health technology platform for quality assurance and quality improvement of malaria diagnosis by community health workers.

    PubMed

    Laktabai, Jeremiah; Platt, Alyssa; Menya, Diana; Turner, Elizabeth L; Aswa, Daniel; Kinoti, Stephen; O'Meara, Wendy Prudhomme

    2018-01-01

    Community health workers (CHWs) play an important role in improving access to services in areas with limited health infrastructure or workforce. Supervision of CHWs by qualified health professionals is the main link between this lay workforce and the formal health system. The quality of services provided by lay health workers is dependent on adequate supportive supervision. It is however one of the weakest links in CHW programs due to logistical and resource constraints, especially in large scale programs. Interventions such as point of care testing using malaria rapid diagnostic tests (RDTs) require real time monitoring to ensure diagnostic accuracy. In this study, we evaluated the utility of a mobile health technology platform to remotely monitor malaria RDT (mRDT) testing by CHWs for quality improvement. As part of a large implementation trial involving mRDT testing by CHWs, we introduced the Fionet system composed of a mobile device (Deki Reader, DR) to assist in processing and automated interpretation of mRDTs, which connects to a cloud-based database which captures reports from the field in real time, displaying results in a custom dashboard of key performance indicators. A random sample of 100 CHWs were trained and provided with the Deki Readers and instructed to use it on 10 successive patients. The CHWs interpretation was compared with the Deki Reader's automatic interpretation, with the errors in processing and interpreting the RDTs recorded. After the CHW entered their interpretation on the DR, the DR provided immediate, automated feedback and interpretation based on its reading of the same cassette. The study team monitored the CHW performance remotely and provided additional support. A total of 1251 primary and 113 repeat tests were performed by the 97 CHWs who used the DR. 91.6% of the tests had agreement between the DR and the CHWs. There were 61 (4.9%) processing and 52 (4.2%) interpretation errors among the primary tests. There was a tendency towards lower odds of errors with increasing number and frequency of tests, though not statistically significant. Of the 62 tests that were repeated due to errors, 79% achieved concordance between the CHW and the DR. Satisfaction with the use of the DR by the CHWs was high. Use of innovative mHealth strategies for monitoring and quality control can ensure quality within a large scale implementation of community level testing by lay health workers.

  7. Beef donor cows with high number of retrieved COC produce more in vitro embryos compared with cows with low number of COC after repeated ovum pick-up sessions.

    PubMed

    Monteiro, F M; Batista, E O S; Vieira, L M; Bayeux, B M; Accorsi, M; Campanholi, S P; Dias, E A R; Souza, A H; Baruselli, P S

    2017-03-01

    The aim of the present study was to evaluate whether repeated ovum pick-up (OPU) procedures may affect the efficiency of OPU programs for in vitro embryo production (IVEP) in Bos indicus (Nelore) donors. In addition, the repeatability (r) efficiency of IVEP was also assessed. Data available were from 432 OPU-IVEP sessions that were performed at random stages of the estrous cycle in 36 cycling, nonlactating Nelore donors. Semen from three Nelore bulls was used for the IVF. Donors were submitted to 12 consecutive OPU procedures, with an interval of approximately 30 days between sessions. Data were analyzed as repeated measures using the GLIMMIX procedure of SAS 9.3. Cows yielding ≥15 COCs were defined as "high" COCs and cows with less than 15 COCs were defined as "low" COCs donors. The number of COCs retrieved decreased over time in donors classified with high COCs and remained fairly steady in cows with low COCs at the beginning of the program (P session*COC retrieved groups  = 0.02). Moreover, the number of COCs retrieved (P < 0.0001), and number of blastocysts produced per OPU (P = 0.001) was greater for the high COCs donors compared with the low COCs category, and these results were consistent across OPU sessions. Interestingly, there was no effect of COCs category on the rate of blastocyst development (P = 0.83). In addition, number of blastocysts produced were not affected by repeated OPU (P = 0.37) and interactions between time and COC category (P = 0.72). Similarly, blastocyst rate was not affected by repeated OPU (P = 0.21) and interactions between time and COC category (P = 0.58). Despite of COC category of the donor cows, repeatability was high for the number of COCs retrieved (r = 0.81), number of blastocysts produced per OPU (r = 0.79), and blastocyst rate (0.69). In conclusion, overall numbers of COCs decreased over time in donors classified as having high COCs. However, cumulative amounts of produced blastocysts were greater in donors with high COCs. More importantly, high repeatability was observed in terms of IVEP efficiency. Therefore, IVEP programs can be significantly improved with more aggressive selection toward donors with greater numbers of COCs. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Accuracy and precision of loadsol® insole force-sensors for the quantification of ground reaction force-based biomechanical running parameters.

    PubMed

    Seiberl, Wolfgang; Jensen, Elisabeth; Merker, Josephine; Leitel, Marco; Schwirtz, Ansgar

    2018-05-29

    Force plates represent the "gold standard" in measuring running kinetics to predict performance or to identify the sources of running-related injuries. As these measurements are generally limited to laboratory analyses, wireless high-quality sensors for measuring in the field are needed. This work analysed the accuracy and precision of a new wireless insole forcesensor for quantifying running-related kinetic parameters. Vertical ground reaction force (GRF) was simultaneously measured with pit-mounted force plates (1 kHz) and loadsol ® sensors (100 Hz) under unshod forefoot and rearfoot running-step conditions. GRF data collections were repeated four times, each separated by 30 min treadmill running, to test influence of extended use. A repeated-measures ANOVA was used to identify differences between measurement devices. Additionally, mean bias and Bland-Altman limits of agreement (LoA) were calculated. We found a significant difference (p < .05) in ground contact time, peak force, and force rate, while there was no difference in parameters impulse, time to peak, and negative force rate. There was no influence of time point of measurement. The mean bias of ground contact time, impulse, peak force, and time to peak ranged between 0.6% and 3.4%, demonstrating high accuracy of loadsol ® devices for these parameters. For these same parameters, the LoA analysis showed that 95% of all measurement differences between insole and force plate measurements were less than 12%, demonstrating high precision of the sensors. However, highly dynamic behaviour of GRF, such as force rate, is not yet sufficiently resolved by the insole devices, which is likely explained by the low sampling rate.

  9. Genetic and Chemical Profiling of Gymnema sylvestre Accessions from Central India: Its Implication for Quality Control and Therapeutic Potential of Plant

    PubMed Central

    Verma, Ashutosh Kumar; Dhawan, Sunita Singh; Singh, Seema; Bharati, Kumar Avinash; Jyotsana

    2016-01-01

    Background: Gymnema sylvestre, a vulnerable plant species, is mentioned in Indian Pharmacopeia as an antidiabetic drug Objective: Study of genetic and chemical diversity and its implications in accessions of G. sylvestre Materials and Methods: Fourteen accessions of G. sylvestre collected from Central India and assessment of their genetic and chemical diversity were carried out using ISSR (inter simple sequence repeat) and HPLC (high performance liquid chromatography) fingerprinting methods Results: Among the screened 40 ISSR primers, 15 were found polymorphic and collectively produced nine unique accession-specific bands. The maximum and minimum numbers of amplicones were noted for ISSR-15 and ISSR-11, respectively. The ISSR -11 and ISSR-13 revealed 100% polymorphism. HPLC chromatograms showed that accessions possess the secondary metabolites of mid-polarity with considerable variability. Unknown peaks with retention time 2.63, 3.41, 23.83, 24.50, and 44.67 were found universal type. Comparative hierarchical clustering analysis based on foresaid fingerprints indicates that both techniques have equal potential to discriminate accessions according to percentage gymnemic acid in their leaf tissue. Second approach was noted more efficiently for separation of accessions according to their agro-climatic/collection site Conclusion: Highly polymorphic ISSRs could be utilized as molecular probes for further selection of high gymnemic acid yielding accessions. Observed accession specific bands may be used as a descriptor for plant accessions protection and converted into sequence tagged sites markers. Identified five universal type peaks could be helpful in identification of G. sylvestre-based various herbal preparations. SUMMARY Nine accession specific unique bandsFive marker peaks for G. sylvestre.Suitability of genetic and chemical fingerprinting Abbreviations used: HPLC: High Performance Liquid Chromatography, ISSR: Inter Simple Sequence Repeats, CTAB: Cetyl Trimethylammonium Bromide, DNTP: Deoxynucleotide Triphosphates PMID:27761067

  10. Genetic and Chemical Profiling of Gymnema sylvestre Accessions from Central India: Its Implication for Quality Control and Therapeutic Potential of Plant.

    PubMed

    Verma, Ashutosh Kumar; Dhawan, Sunita Singh; Singh, Seema; Bharati, Kumar Avinash; Jyotsana

    2016-07-01

    Gymnema sylvestre , a vulnerable plant species, is mentioned in Indian Pharmacopeia as an antidiabetic drug. Study of genetic and chemical diversity and its implications in accessions of G. sylvestre . Fourteen accessions of G. sylvestre collected from Central India and assessment of their genetic and chemical diversity were carried out using ISSR (inter simple sequence repeat) and HPLC (high performance liquid chromatography) fingerprinting methods. Among the screened 40 ISSR primers, 15 were found polymorphic and collectively produced nine unique accession-specific bands. The maximum and minimum numbers of amplicones were noted for ISSR-15 and ISSR-11, respectively. The ISSR -11 and ISSR-13 revealed 100% polymorphism. HPLC chromatograms showed that accessions possess the secondary metabolites of mid-polarity with considerable variability. Unknown peaks with retention time 2.63, 3.41, 23.83, 24.50, and 44.67 were found universal type. Comparative hierarchical clustering analysis based on foresaid fingerprints indicates that both techniques have equal potential to discriminate accessions according to percentage gymnemic acid in their leaf tissue. Second approach was noted more efficiently for separation of accessions according to their agro-climatic/collection site. Highly polymorphic ISSRs could be utilized as molecular probes for further selection of high gymnemic acid yielding accessions. Observed accession specific bands may be used as a descriptor for plant accessions protection and converted into sequence tagged sites markers. Identified five universal type peaks could be helpful in identification of G. sylvestre -based various herbal preparations. Nine accession specific unique bandsFive marker peaks for G. sylvestre .Suitability of genetic and chemical fingerprinting Abbreviations used: HPLC: High Performance Liquid Chromatography, ISSR: Inter Simple Sequence Repeats, CTAB: Cetyl Trimethylammonium Bromide, DNTP: Deoxynucleotide Triphosphates.

  11. Aerodynamic and engineering design of a 1.5 s high quality microgravity drop tower facility

    NASA Astrophysics Data System (ADS)

    Belser, Valentin; Breuninger, Jakob; Reilly, Matthew; Laufer, René; Dropmann, Michael; Herdrich, Georg; Hyde, Truell; Röser, Hans-Peter; Fasoulas, Stefanos

    2016-12-01

    Microgravity experiments are essential for research in space science, biology, fluid mechanics, combustion, and material sciences. One way to conduct microgravity experiments on Earth is by using drop tower facilities. These facilities combine a high quality of microgravity, adequate payload masses and have the advantage of virtually unlimited repeatability under same experimental conditions, at a low cost. In a collaboration between the Institute of Space Systems (IRS) at the University of Stuttgart and Baylor University (BU) in Waco, Texas, a new drop tower is currently under development at the Center for Astrophysics, Space Physics and Engineering Research (CASPER). The design parameters of the drop tower ask for at least 1.5 s in free fall duration while providing a quality of at least 10-5 g. Previously, this quality has only been achieved in vacuum drop tower facilities where the capsule experiences virtually zero aerodynamic drag during its free fall. Since this design comes at high costs, a different drop tower design concept, which does not require an evacuated drop shaft, was chosen. It features a dual-capsule system in which the experiment capsule is shielded from aerodynamic forces by surrounding it with a drag shield during the drop. As no other dual-capsule drop tower has been able to achieve a quality as good as or better than 10-5 g previous work optimized the design with an aerodynamic perspective by using computational fluid dynamics (CFD) simulations to determine the ideal shape and size of the outer capsule and to specify the aerodynamically crucial dimensions for the overall system. Experiments later demonstrated that the required quality of microgravity can be met with the proposed design. The main focus of this paper is the mechanical realization of the capsule as well as the development and layout of the surrounding components, such as the release mechanism, the deceleration device and the drop shaft. Because the drop tower facility is a complex system with many interdependencies between all of the components, several engineering challenges had to be addressed. For example, initial disturbances that are caused by the release mechanism are a common issue that arises at drop tower facilities. These vibrations may decrease the quality of microgravity during the initial segment of free fall. Because this would reduce the free fall time experiencing high quality microgravity, a mechanism has been developed to provide a soft release. Challenges and proposed solutions for all components are highlighted in this paper.

  12. Generating Modeling Data From Repeat-Dose Toxicity Reports

    PubMed Central

    López-Massaguer, Oriol; Pinto-Gil, Kevin; Sanz, Ferran; Amberg, Alexander; Anger, Lennart T; Stolte, Manuela; Ravagli, Carlo

    2018-01-01

    Abstract Over the past decades, pharmaceutical companies have conducted a large number of high-quality in vivo repeat-dose toxicity (RDT) studies for regulatory purposes. As part of the eTOX project, a high number of these studies have been compiled and integrated into a database. This valuable resource can be queried directly, but it can be further exploited to build predictive models. As the studies were originally conducted to investigate the properties of individual compounds, the experimental conditions across the studies are highly heterogeneous. Consequently, the original data required normalization/standardization, filtering, categorization and integration to make possible any data analysis (such as building predictive models). Additionally, the primary objectives of the RDT studies were to identify toxicological findings, most of which do not directly translate to in vivo endpoints. This article describes a method to extract datasets containing comparable toxicological properties for a series of compounds amenable for building predictive models. The proposed strategy starts with the normalization of the terms used within the original reports. Then, comparable datasets are extracted from the database by applying filters based on the experimental conditions. Finally, carefully selected profiles of toxicological findings are mapped to endpoints of interest, generating QSAR-like tables. In this work, we describe in detail the strategy and tools used for carrying out these transformations and illustrate its application in a data sample extracted from the eTOX database. The suitability of the resulting tables for developing hazard-predicting models was investigated by building proof-of-concept models for in vivo liver endpoints. PMID:29155963

  13. Reliability and validity of bilateral ankle accelerometer algorithms for activity recognition and walking speed after stroke.

    PubMed

    Dobkin, Bruce H; Xu, Xiaoyu; Batalin, Maxim; Thomas, Seth; Kaiser, William

    2011-08-01

    Outcome measures of mobility for large stroke trials are limited to timed walks for short distances in a laboratory, step counters and ordinal scales of disability and quality of life. Continuous monitoring and outcome measurements of the type and quantity of activity in the community would provide direct data about daily performance, including compliance with exercise and skills practice during routine care and clinical trials. Twelve adults with impaired ambulation from hemiparetic stroke and 6 healthy controls wore triaxial accelerometers on their ankles. Walking speed for repeated outdoor walks was determined by machine-learning algorithms and compared to a stopwatch calculation of speed for distances not known to the algorithm. The reliability of recognizing walking, exercise, and cycling by the algorithms was compared to activity logs. A high correlation was found between stopwatch-measured outdoor walking speed and algorithm-calculated speed (Pearson coefficient, 0.98; P=0.001) and for repeated measures of algorithm-derived walking speed (P=0.01). Bouts of walking >5 steps, variations in walking speed, cycling, stair climbing, and leg exercises were correctly identified during a day in the community. Compared to healthy subjects, those with stroke were, as expected, more sedentary and slower, and their gait revealed high paretic-to-unaffected leg swing ratios. Test-retest reliability and concurrent and construct validity are high for activity pattern-recognition Bayesian algorithms developed from inertial sensors. This ratio scale data can provide real-world monitoring and outcome measurements of lower extremity activities and walking speed for stroke and rehabilitation studies.

  14. Large-scale grain growth in the solid-state process: From "Abnormal" to "Normal"

    NASA Astrophysics Data System (ADS)

    Jiang, Minhong; Han, Shengnan; Zhang, Jingwei; Song, Jiageng; Hao, Chongyan; Deng, Manjiao; Ge, Lingjing; Gu, Zhengfei; Liu, Xinyu

    2018-02-01

    Abnormal grain growth (AGG) has been a common phenomenon during the ceramic or metallurgy processing since prehistoric times. However, usually it had been very difficult to grow big single crystal (centimeter scale over) by using the AGG method due to its so-called occasionality. Based on the AGG, a solid-state crystal growth (SSCG) method was developed. The greatest advantages of the SSCG technology are the simplicity and cost-effectiveness of the technique. But the traditional SSCG technology is still uncontrollable. This article first summarizes the history and current status of AGG, and then reports recent technical developments from AGG to SSCG, and further introduces a new seed-free, solid-state crystal growth (SFSSCG) technology. This SFSSCG method allows us to repeatedly and controllably fabricate large-scale single crystals with appreciable high quality and relatively stable chemical composition at a relatively low temperature, at least in (K0.5Na0.5)NbO3(KNN) and Cu-Al-Mn systems. In this sense, the exaggerated grain growth is no longer 'Abnormal' but 'Normal' since it is able to be artificially controllable and repeated now. This article also provides a crystal growth model to qualitatively explain the mechanism of SFSSCG for KNN system. Compared with the traditional melt and high temperature solution growth methods, the SFSSCG method has the advantages of low energy consumption, low investment, simple technique, composition homogeneity overcoming the issues with incongruent melting and high volatility. This SFSSCG could be helpful for improving the mechanical and physical properties of single crystals, which should be promising for industrial applications.

  15. Comparison of nitrous oxide (N2O) analyzers for high-precision measurements of atmospheric mole fractions

    NASA Astrophysics Data System (ADS)

    Lebegue, B.; Schmidt, M.; Ramonet, M.; Wastine, B.; Yver Kwok, C.; Laurent, O.; Belviso, S.; Guemri, A.; Philippon, C.; Smith, J.; Conil, S.; Jost, H. J.; Crosson, E. R.

    2015-10-01

    Over the last few decades, in-situ measurements of atmospheric N2O mole fractions have been performed using gas chromatographs (GCs) equipped with electron capture detectors (ECDs). When trying to meet the World Meteorological Organization's (WMO) quality goal, this technique becomes very challenging as the detectors are highly non-linear and the GCs at remote stations require a considerable amount of maintenance by qualified technicians to maintain good short-term and long-term repeatability. With more robust optical spectrometers being now available for N2O measurements, we aim to identify a robust and stable analyzer that can be integrated into atmospheric monitoring networks, such as the Integrated Carbon Observation System (ICOS). In this study, we tested seven analyzers that were developed and commercialized from five different companies and compared the results with established techniques. Each instrument was characterized during a time period of approximately eight weeks. The test protocols included the characterization of the short-term and long-term repeatability, drift, temperature dependence, linearity and sensitivity to water vapor. During the test period, ambient air measurements were compared under field conditions at the Gif-sur-Yvette station. All of the analyzers showed a standard deviation better than 0.1 ppb for the 10 min averages. Some analyzers would benefit from improvements in temperature stability to reduce the instrument drift, which could then help in reducing the frequency of calibrations. For most instruments, the water vapor correction algorithms applied by companies are not sufficient for high-precision atmospheric measurements, which results in the need to dry the ambient air prior to analysis.

  16. Development of a hydrologic connectivity dataset for SWAT assessments in the U.S.

    USDA-ARS?s Scientific Manuscript database

    Model based water quality assessments are as important informer of conservation and environmental policy in the US. The recently completed national scale Conservation Effects Assessment Project (CEAP) is being repeated using newer data, greater resolution, and enhanced models. National assessment...

  17. Effects of outdoor education stream classes on substrate movement and macroinvertebrate colonization

    USDA-ARS?s Scientific Manuscript database

    Environmental education and stream quality monitoring overlap in stream classes conducted at resident outdoor education (ROE) programs. ROE programs frequently use the same stream locations for their stream classes. The repeated use of the same location can potentially degrade aquatic macroinverte...

  18. Repeatability analysis of the K. J. Law Model 8300 Roughness Surveyor : final report.

    DOT National Transportation Integrated Search

    1991-04-01

    The K.J. Law Model 8300 Roughness surveyor, is a ride-quality measurement device used to determine and analyze the longitudinal roadway profile. This paper describes an analysis of IRI data as collected with Louisiana's Roughness Surveyor to determin...

  19. Repeat-aware modeling and correction of short read errors.

    PubMed

    Yang, Xiao; Aluru, Srinivas; Dorman, Karin S

    2011-02-15

    High-throughput short read sequencing is revolutionizing genomics and systems biology research by enabling cost-effective deep coverage sequencing of genomes and transcriptomes. Error detection and correction are crucial to many short read sequencing applications including de novo genome sequencing, genome resequencing, and digital gene expression analysis. Short read error detection is typically carried out by counting the observed frequencies of kmers in reads and validating those with frequencies exceeding a threshold. In case of genomes with high repeat content, an erroneous kmer may be frequently observed if it has few nucleotide differences with valid kmers with multiple occurrences in the genome. Error detection and correction were mostly applied to genomes with low repeat content and this remains a challenging problem for genomes with high repeat content. We develop a statistical model and a computational method for error detection and correction in the presence of genomic repeats. We propose a method to infer genomic frequencies of kmers from their observed frequencies by analyzing the misread relationships among observed kmers. We also propose a method to estimate the threshold useful for validating kmers whose estimated genomic frequency exceeds the threshold. We demonstrate that superior error detection is achieved using these methods. Furthermore, we break away from the common assumption of uniformly distributed errors within a read, and provide a framework to model position-dependent error occurrence frequencies common to many short read platforms. Lastly, we achieve better error correction in genomes with high repeat content. The software is implemented in C++ and is freely available under GNU GPL3 license and Boost Software V1.0 license at "http://aluru-sun.ece.iastate.edu/doku.php?id = redeem". We introduce a statistical framework to model sequencing errors in next-generation reads, which led to promising results in detecting and correcting errors for genomes with high repeat content.

  20. Examining extrinsic factors that influence product acceptance: a review.

    PubMed

    Li, X E; Jervis, S M; Drake, M A

    2015-05-01

    Drivers of liking (DOL) studies are useful for product development to formulate acceptable products; however, DOL alone are insufficient for understanding why a product is purchased and repurchased, which is ultimately the indication of a successful product. Ultimately sensory attributes drive product success (that is, repeat and continued purchase). However, ignoring the importance of extrinsic factors may neglect the vital product attributes responsible for the initial purchase, which may in turn, affect repeat purchase. The perception of sensory attributes assessed by DOL is mitigated by external perceptions of quality. If the sensory attributes do not deliver based upon the quality cues, the product will not be acceptable. Four key extrinsic factors that affect DOL are the perceived satiety, brand and labeling, price, and the emotional impact to decision making. In order to more thoroughly understand what the DOL for a product is, these 4 product cues should be considered in conjunction with sensory attribute perception to gain a holistic understanding of product acceptance. © 2015 Institute of Food Technologists®

  1. Water-quality data for the Ohio River from New Cumberland Dam to Pike Island Dam, West Virginia and Ohio, June-November 1992

    USGS Publications Warehouse

    Miller, Kimberly F.; Faulkenburg, C.W.; Chambers, D.B.; Waldron, M.C.

    1995-01-01

    This report contains water-quality data for the Ohio River, collected during the summer and fall of 1992, from river mile 51.1 (3.3 miles upstream from New Cumberland Dam) to river mile 84.0 (0.2 miles upstream from Pike Island Dam). The data were collected to assess the effects of hydropower development on water quality. Water quality was determined by a combination of repeated synoptic field measurements and laboratory analyses. Synoptic measurements were made along a longitudinal transect with 18 mid-channel sampling sites; cross-sectional transects of water quality were measured at 5 of these sites. Water-quality measurements also were made at two sites located on the back-channel (Ohio) side of Browns Island. Water temperature, dissolved oxygen concentration, pH, and specific conductance were measured at each longitudinal-transect and back-channel sampling site. Longitudinal-transect and back-channel stations were sampled at three depths (about 3.3 feet below the surface of the water, middle of the water column, and near the bottom of the river). Cross-sectional transects consisted of three or four detailed vertical pro- files of the same characteristics. Water samples were collected from three depths at the mid-channel vertical profile in each cross-sectional transect and were analyzed for concentrations of phyto- plankton photosynthetic pigments chlorophyll a and chlorophyll b. Estimates of the depth of light penetration (Secchi disk transparency) were made at pigment-sampling locations whenever light and river-surface conditions were appropriate. Synoptic sampling usually was completed in 12 hours or less and was repeated seven times between June 25 and November 6, 1992.

  2. Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

    PubMed

    Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia

    2016-04-01

    Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model's template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, [Formula: see text], was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using [Formula: see text] from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO.

  3. Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography

    PubMed Central

    Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia

    2016-01-01

    Abstract. Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model’s template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, Az, was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using Az from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO. PMID:27284547

  4. Distribution of the FMR1 gene in females by race/ethnicity: women with diminished ovarian reserve versus women with normal fertility (SWAN study).

    PubMed

    Pastore, Lisa M; Young, Steven L; Manichaikul, Ani; Baker, Valerie L; Wang, Xin Q; Finkelstein, Joel S

    2017-01-01

    To study whether reported, but inconsistent, associations between the FMR1 CGG repeat lengths in the intermediate, high normal, or low normal range differentiate women diagnosed with diminished ovarian reserve (DOR) from population controls and whether associations vary by race/ethnic group. Case-control study. Academic and private fertility clinics. DOR cases (n = 129; 95 Whites, 22 Asian, 12 other) from five U.S. fertility clinics were clinically diagnosed, with regular menses and no fragile X syndrome family history. Normal fertility controls (n = 803; 386 Whites, 219 African-Americans, 102 Japanese, 96 Chinese) from the United States-based SWAN Study had one or more menstrual period in the 3 months pre-enrollment, one or more pregnancy, no history of infertility or hormone therapy, and menopause ≥46 years. Previously, the SWAN Chinese and Japanese groups had similar FMR1 CGG repeat lengths, thus they were combined. None. FMR1 CGG repeat lengths. Median CGG repeats were nearly identical by case/control group. DOR cases had fewer CGG repeats in the shorter FMR1 allele than controls among Whites, but this was not significant among Asians. White cases had fewer CGG repeats in the shorter allele than Asian cases. No significant differences were found in the high normal/intermediate range between cases and controls or by race/ethnic group within cases in the longer allele. This study refutes prior reports of an association between DOR and high normal/intermediate repeats and confirms an association between DOR and low normal repeats in Whites. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Similarities in the chromosomal distribution of AG and AC repeats within and between Drosophila, human and barley chromosomes.

    PubMed

    Cuadrado, A; Jouve, N

    2007-01-01

    Two simple sequence repeats (SSRs), AG and AC, were mapped directly in the metaphase chromosomes of man and barley (Hordeum vulgare L.), and in the metaphase and polytene chromosomes of Drosophila melanogaster. To this end, synthetic oligonucleotides corresponding to (AG)(12) and (AC)(8) were labelled by the random primer technique and used as probes in fluorescent in situ hybridisation (FISH) under high stringency and strict washing conditions. The distribution and intensity of the signals for the repeat sequences were found to be characteristic of the chromosomes and genomes of the three species analysed. The AC repeat sites were uniformly dispersed along the euchromatic segments of all three genomes; in fact, they were largely excluded from the heterochromatin. The Drosophila genome showed a high density of AC sequences on the X chromosome in both mitotic and polytene nuclei. In contrast, the AG repeats were associated with the euchromatic regions of the polytene chromosomes (and in high density on the X chromosome), but were only seen in specific heterochromatic regions in the mitotic chromosomes of all three species. In Drosophila, the AG repeats were exclusively distributed on the tips of the Y chromosome and near the centromere on both arms of chromosome 2. In barley and man, AG repeats were associated with the centromeres (of all chromosomes) and nucleolar organizer regions, respectively. The conserved chromosome distribution of AC within and between these three phylogenetically distant species, and the association of AG in specific chromosome regions with structural or functional properties, suggests that long clusters of these repeats may have some, as yet unknown, role. Copyright (c) 2007 S. Karger AG, Basel.

  6. THICKNESS OF THE MACULA, RETINAL NERVE FIBER LAYER, AND GANGLION CELL-INNER PLEXIFORM LAYER IN THE AGE-RELATED MACULAR DEGENERATION: The Repeatability Study of Spectral Domain Optical Coherence Tomography.

    PubMed

    Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul

    2018-02-01

    To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT < 200 μm; B group, 200 μm ≤ CMT < 300 μm; and C group, CMT > 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.

  7. Large scale production of highly-qualified graphene by ultrasonic exfoliation of expanded graphite under the promotion of (NH4)2CO3 decomposition.

    PubMed

    Wang, Yunwei; Tong, Xili; Guo, Xiaoning; Wang, Yingyong; Jin, Guoqiang; Guo, Xiangyun

    2013-11-29

    Highly-qualified graphene was prepared by the ultrasonic exfoliation of commercial expanded graphite (EG) under the promotion of (NH4)2CO3 decomposition. The yield of graphene from the first exfoliation is 7 wt%, and it can be increased to more than 65 wt% by repeated exfoliations. Atomic force microscopy, x-ray photoelectron spectroscopy and Raman analysis show that the as-prepared graphene only has a few defects or oxides, and more than 95% of the graphene flakes have a thickness of ~1 nm. The electrochemical performance of the as-prepared graphene is comparable to reduced graphene oxide in the determination of dopamine (DA) from the mixed solution of ascorbic acid, uric acid and DA. These results show that the decomposition of (NH4)2CO3 molecules in the EG layers under ultrasonication promotes the exfoliation of graphite and provides a low-priced route for large scale production of highly-quality graphene.

  8. Large scale production of highly-qualified graphene by ultrasonic exfoliation of expanded graphite under the promotion of (NH4)2CO3 decomposition

    NASA Astrophysics Data System (ADS)

    Wang, Yunwei; Tong, Xili; Guo, Xiaoning; Wang, Yingyong; Jin, Guoqiang; Guo, Xiangyun

    2013-11-01

    Highly-qualified graphene was prepared by the ultrasonic exfoliation of commercial expanded graphite (EG) under the promotion of (NH4)2CO3 decomposition. The yield of graphene from the first exfoliation is 7 wt%, and it can be increased to more than 65 wt% by repeated exfoliations. Atomic force microscopy, x-ray photoelectron spectroscopy and Raman analysis show that the as-prepared graphene only has a few defects or oxides, and more than 95% of the graphene flakes have a thickness of ˜1 nm. The electrochemical performance of the as-prepared graphene is comparable to reduced graphene oxide in the determination of dopamine (DA) from the mixed solution of ascorbic acid, uric acid and DA. These results show that the decomposition of (NH4)2CO3 molecules in the EG layers under ultrasonication promotes the exfoliation of graphite and provides a low-priced route for large scale production of highly-quality graphene.

  9. Avalanche solar blind photodetectors based on single crystalline Mg0.47Zn0.53O thin film on Ga:ZnO substrate

    NASA Astrophysics Data System (ADS)

    Chen, Hao; Zhang, Jingtao; Chen, Zuxin; Liu, Huiqiang; Ma, Xinzhou; Li, Qiuguo; Chu, Guang; Chu, Sheng

    2018-05-01

    Single crystalline wurtzite Mg0.47Zn0.53O films were grown on Ga:ZnO substrates by pulse laser deposition. The band gap of the films was measured to be 4.43 eV. Vertical devices were fabricated for solar blind photodetection, realizing a high responsivity of 2 A W‑1 at 278 nm and  ‑5 V bias as well as a rejection ratio (R 278 nm/R 350 nm) of over 6  ×  103. A cut-off wavelength of 286 nm and a response time of 77 ms were also achieved. Besides, the devices showed stable response without degeneration under repeating illumination. The high performance of this photodetector was analyzed and attributed to the avalanche effect from high quality Mg0.47Zn0.53O/Ga:ZnO heterojunction at reverse bias. The avalanche gain was calculated to be 14.5 at  ‑10 V.

  10. Don't just repeat after me: retrieval practice is better than imitation for foreign vocabulary learning.

    PubMed

    Kang, Sean H K; Gollan, Tamar H; Pashler, Harold

    2013-12-01

    Second language (L2) instruction programs often ask learners to repeat aloud words spoken by a native speaker. However, recent research on retrieval practice has suggested that imitating native pronunciation might be less effective than drill instruction, wherein the learner is required to produce the L2 words from memory (and given feedback). We contrasted the effectiveness of imitation and retrieval practice drills on learning L2 spoken vocabulary. Learners viewed pictures of objects and heard their names; in the imitation condition, they heard and then repeated aloud each name, whereas in the retrieval practice condition, they tried to produce the name before hearing it. On a final test administered either immediately after training (Exp. 1) or after a 2-day delay (Exp. 2), retrieval practice produced better comprehension of the L2 words, better ability to produce the L2 words, and no loss of pronunciation quality.

  11. Running With the Pack: Teen Peer-Relationship Qualities as Predictors of Adult Physical Health.

    PubMed

    Allen, Joseph P; Uchino, Bert N; Hafen, Christopher A

    2015-10-01

    This study assessed qualities of adolescent peer relationships as long-term predictors of physical health quality in adulthood. In an intensive multimethod, multireporter study of a community sample of 171 individuals assessed repeatedly from the ages of 13 to 27 years, physical health quality in adulthood was robustly predicted by independent reports of early-adolescent close-friendship quality and by a pattern of acquiescence to social norms in adolescent peer relationships. Predictions remained after accounting for numerous potential confounds, including prior health problems, concurrent body mass index, anxious and depressive symptoms, personality characteristics, adolescent-era financial adversity, and adolescent-era physical attractiveness. These findings have important implications for understanding the unique intensity of peer relationships in adolescence. © The Author(s) 2015.

  12. A systematic approach for evaluating and scoring human data.

    PubMed

    Money, Chris D; Tomenson, John A; Penman, Michael G; Boogaard, Peter J; Jeffrey Lewis, R

    2013-07-01

    An approach is described for how the quality of human data can be systematically assessed and categorised. The approach mirrors the animal data quality considerations set out by Klimisch et al., in order that human data quality can be addressed in a complementary manner and to help facilitate transparent (and repeatable) weight of evidence comparisons. Definitions are proposed for the quality and adequacy of data. Quality is differentiated into four categories. A description of how the scheme can be used for evaluating data reliability, especially for use when contributing entries to the IUCLID database, is shown. A discussion of how the criteria might also be used when determining overall data relevance is included. The approach is intended to help harmonise human data evaluation processes worldwide. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. [FQA: A method for floristic quality assessment based on conservatism of plant species].

    PubMed

    Cao, Li Juan; He, Ping; Wang, Mi; Xui, Jie; Ren, Ying

    2018-04-01

    FQA, which uses the conservatism of plant species for particular habitats and the species richness of plant communities, is a rapid method for the assessment of habitat quality. This method is based on species composition of quadrats and coefficients of conservatism for species which assigned by experts. Floristic Quality Index (FQI) that reflects vegetation integrity and degradation of a site can be calculated by a simple formula and be used for space-time comparison of habitat quality. It has been widely used in more than ten countries including the United States and Canada. This paper presented the principle, calculation formulas and application cases of this method, with the aim to provide a simple, repeatable and comparable method to assess habitat quality for ecological managers and researchers.

  14. Pediatric digital chest imaging.

    PubMed

    Tarver, R D; Cohen, M; Broderick, N J; Conces, D J

    1990-01-01

    The Philips Computed Radiography system performs well with pediatric portable chest radiographs, handling the throughout of a busy intensive care service 24 hours a day. Images are excellent and routinely provide a conventional (unenhanced) image and an edge-enhanced image. Radiation dose is decreased by the lowered frequency of repeat examinations and the ability of the plates to respond to a much lower dose and still provide an adequate image. The high quality and uniform density of serial PCR portable radiographs greatly enhances diagnostic content of the films. Decreased resolution has not been a problem clinically. Image manipulation and electronic transfer to remote viewing stations appear to be helpful and are currently being evaluated further. The PCR system provides a marked improvement in pediatric portable chest radiology.

  15. Eating Better for Less: A National Discount Program for Healthy Food Purchases in South Africa

    PubMed Central

    An, Ruopeng; Patel, Deepak; Segal, Darren; Sturm, Roland

    2012-01-01

    Background Improving diet quality is a key health promotion strategy. The HealthyFood program provides up to a 25% discount on selected food items to about 260,000 households across South Africa. Objectives Examine whether reducing prices for healthy food purchases leads to changes in self-reported measures of food consumption and weight status. Methods Repeated surveys of about 350,000 HealthyFood participants and nonparticipants. Results Program participation is associated with more consumption of fruits/vegetables and wholegrain foods, and less consumption of high sugar/salt foods, fried foods, processed meats, and fast-food. There is no strong evidence that participation reduces obesity. Conclusions A substantial price intervention might be effective in improving diets. PMID:22943101

  16. Psi- vectors: murine leukemia virus-based self-inactivating and self-activating retroviral vectors.

    PubMed Central

    Delviks, K A; Hu, W S; Pathak, V K

    1997-01-01

    We have developed murine leukemia virus (MLV)-based self-inactivating and self-activating vectors to show that the previously demonstrated high-frequency direct repeat deletions are not unique to spleen necrosis virus (SNV) or the neomycin drug resistance gene. Retroviral vectors pKD-HTTK and pKD-HTpTK containing direct repeats composed of segments of the herpes simplex virus type 1 thymidine kinase (HTK) gene were constructed; in pKD-HTpTK, the direct repeat flanked the MLV packaging signal. The generation of hypoxanthine-aminopterin-thymidine-resistant colonies after one cycle of retroviral replication demonstrated functional reconstitution of the HTK gene. Quantitative Southern analysis indicated that direct repeat deletions occurred in 57 and 91% of the KD-HTTK and KD-HTpTK proviruses, respectively. These results demonstrate that (i) deletion of direct repeats occurs at similar high frequencies in SNV and MLV vectors, (ii) MLV psi can be efficiently deleted by using direct repeats, (iii) suicide genes can be functionally reconstituted during reverse transcription, and (iv) the psi region may be a hot spot for reverse transcriptase template switching events. PMID:9223521

  17. A Cost-Utility Analysis of Lung Cancer Screening and the Additional Benefits of Incorporating Smoking Cessation Interventions

    PubMed Central

    Villanti, Andrea C.; Jiang, Yiding; Abrams, David B.; Pyenson, Bruce S.

    2013-01-01

    Background A 2011 report from the National Lung Screening Trial indicates that three annual low-dose computed tomography (LDCT) screenings for lung cancer reduced lung cancer mortality by 20% compared to chest X-ray among older individuals at high risk for lung cancer. Discussion has shifted from clinical proof to financial feasibility. The goal of this study was to determine whether LDCT screening for lung cancer in a commercially-insured population (aged 50–64) at high risk for lung cancer is cost-effective and to quantify the additional benefits of incorporating smoking cessation interventions in a lung cancer screening program. Methods and Findings The current study builds upon a previous simulation model to estimate the cost-utility of annual, repeated LDCT screenings over 15 years in a high risk hypothetical cohort of 18 million adults between age 50 and 64 with 30+ pack-years of smoking history. In the base case, the lung cancer screening intervention cost $27.8 billion over 15 years and yielded 985,284 quality-adjusted life years (QALYs) gained for a cost-utility ratio of $28,240 per QALY gained. Adding smoking cessation to these annual screenings resulted in increases in both the costs and QALYs saved, reflected in cost-utility ratios ranging from $16,198 per QALY gained to $23,185 per QALY gained. Annual LDCT lung cancer screening in this high risk population remained cost-effective across all sensitivity analyses. Conclusions The findings of this study indicate that repeat annual lung cancer screening in a high risk cohort of adults aged 50–64 is highly cost-effective. Offering smoking cessation interventions with the annual screening program improved the cost-effectiveness of lung cancer screening between 20% and 45%. The cost-utility ratios estimated in this study were in line with other accepted cancer screening interventions and support inclusion of annual LDCT screening for lung cancer in a high risk population in clinical recommendations. PMID:23940744

  18. An analysis of cluster headache information provided on internet websites.

    PubMed

    Peterlin, B Lee; Gambini-Suarez, Eduardo; Lidicker, Jeffrey; Levin, Morris

    2008-03-01

    To evaluate the quality of websites providing cluster headache information for patients and healthcare providers. The Internet has become an increasingly important source of healthcare information. However, limited data exist regarding the quality of websites providing headache information. This was a cross-sectional study conducted in February 2007. Websites providing cluster headache information were determined on the search engine MetaCrawler and classified as either patient oriented or healthcare provider oriented. The overall quality of each site was evaluated using a score system. Readability was evaluated using the Flesch-Kincaid Grade Level Readability Score (FKRS). Website quality was analyzed based on ownership, purpose, authorship, author qualifications, attribution, interactivity, and currency. The technical quality of the cluster headache information was analyzed based on content specific to cluster headache. The final ranking, based on the sum of the ranks of all 3 categories, was determined and then contrasted between the patient-oriented and healthcare professional-oriented websites using 2-sample t-tests. Of the first 40 websites found on MetaCrawler, 72.5% were advertisements, unrelated to headache, or repeated websites. Although the standard US writing averages are at a seventh to eighth grade level, the mean FKRS of all sites was at a 12th grade level of difficulty, with no significant difference between the patient-oriented or healthcare provider-oriented websites (P = .54). Of a total possible 14 points, the overall mean quality component score was 9.9 for all sites; and of a total possible 23 points, the overall mean technical component score was 13.9. There was no significant difference for either the quality or technical component scores between patient-oriented or healthcare provider-oriented websites (P = .45 and P = .80, respectively). There are numerous cluster headache websites that can be found on the Internet. The quality of most of the websites dedicated to cluster headache is mediocre, and although there are some excellent cluster headache websites, these sites may be challenging for many users to locate. There was no significant difference in the overall quality of websites oriented for patients or healthcare providers providing cluster headache information evaluated in this study. In addition, websites providing high-quality cluster headache information are written at an educational level too high for a significant portion of the general population to fully utilize. Physicians should strongly consider providing lists of quality websites on cluster headache for their patients.

  19. Body Image, Personality Traits, and Quality of Life in Botulinum Toxin A and Dermal Filler Patients.

    PubMed

    Scharschmidt, Dagmar; Mirastschijski, Ursula; Preiss, Simone; Brähler, Elmar; Fischer, Tanja; Borkenhagen, A

    2018-06-11

    The demand for minimally invasive cosmetic procedures has continued to rise, especially in Germany, yet few studies have examined this patient population. The literature in Germany has repeatedly voiced the speculation that users of minimally invasive, skin-rejuvenating procedures displayed a higher tendency toward dysmorphic behavior patterns or, respectively, other abnormal personality traits. The aim of this study was to investigate body image, personality traits, quality of life, and socioeconomic parameters in users of botulinum toxin and/or facial fillers. One hundred forty-five females presented for botulinum toxin and/or soft tissue filler injections completed demographic and standardized psychometric questionnaires such as the World-Health-Organization Quality of Life-Short Form, Big Five Inventory-10, Body Dysmorphic Disorder Questionnaire before treatment. Patients undergoing injectable aesthetic treatments in an urban dermatology practice were women, middle-aged, highly educated, and mostly employed. Furthermore, participants showed higher quality of life, especially health-related quality of life, and a lower body mass index than controls. Concerning personality traits, our participants scored significantly higher on extraversion, agreeableness, openness to experience, and neuroticism. This study helps to better understand the psychosocial factors characterizing this patient population. Patients differ from controls by having a higher level of quality of life. No signs of body dysmorphic patterns or problematic personality traits were found. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. Solution properties of the archaeal CRISPR DNA repeat-binding homeodomain protein Cbp2

    PubMed Central

    Kenchappa, Chandra S.; Heidarsson, Pétur O.; Kragelund, Birthe B.; Garrett, Roger A.; Poulsen, Flemming M.

    2013-01-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) form the basis of diverse adaptive immune systems directed primarily against invading genetic elements of archaea and bacteria. Cbp1 of the crenarchaeal thermoacidophilic order Sulfolobales, carrying three imperfect repeats, binds specifically to CRISPR DNA repeats and has been implicated in facilitating production of long transcripts from CRISPR loci. Here, a second related class of CRISPR DNA repeat-binding protein, denoted Cbp2, is characterized that contains two imperfect repeats and is found amongst members of the crenarchaeal thermoneutrophilic order Desulfurococcales. DNA repeat-binding properties of the Hyperthermus butylicus protein Cbp2Hb were characterized and its three-dimensional structure was determined by NMR spectroscopy. The two repeats generate helix-turn-helix structures separated by a basic linker that is implicated in facilitating high affinity DNA binding of Cbp2 by tethering the two domains. Structural studies on mutant proteins provide support for Cys7 and Cys28 enhancing high thermal stability of Cbp2Hb through disulphide bridge formation. Consistent with their proposed CRISPR transcriptional regulatory role, Cbp2Hb and, by inference, other Cbp1 and Cbp2 proteins are closely related in structure to homeodomain proteins with linked helix-turn-helix (HTH) domains, in particular the paired domain Pax and Myb family proteins that are involved in eukaryal transcriptional regulation. PMID:23325851

Top