Quality Market: Design and Field Study of Prediction Market for Software Quality Control
ERIC Educational Resources Information Center
Krishnamurthy, Janaki
2010-01-01
Given the increasing competition in the software industry and the critical consequences of software errors, it has become important for companies to achieve high levels of software quality. While cost reduction and timeliness of projects continue to be important measures, software companies are placing increasing attention on identifying the user…
Evaluating Software Assurance Knowledge and Competency of Acquisition Professionals
2014-10-01
of ISO 12207 -2008, both internationally and in the United States [7]. That standard documents a comprehensive set of activities and supporting...grows, organizations must ensure that their procurement agents acquire high quality, secure software. ISO 12207 and the Software Assurance Competency...cyberattacks grows, organizations must ensure that their procurement agents acquire high quality, secure software. ISO 12207 and the Software Assurance
Predicting Software Suitability Using a Bayesian Belief Network
NASA Technical Reports Server (NTRS)
Beaver, Justin M.; Schiavone, Guy A.; Berrios, Joseph S.
2005-01-01
The ability to reliably predict the end quality of software under development presents a significant advantage for a development team. It provides an opportunity to address high risk components earlier in the development life cycle, when their impact is minimized. This research proposes a model that captures the evolution of the quality of a software product, and provides reliable forecasts of the end quality of the software being developed in terms of product suitability. Development team skill, software process maturity, and software problem complexity are hypothesized as driving factors of software product quality. The cause-effect relationships between these factors and the elements of software suitability are modeled using Bayesian Belief Networks, a machine learning method. This research presents a Bayesian Network for software quality, and the techniques used to quantify the factors that influence and represent software quality. The developed model is found to be effective in predicting the end product quality of small-scale software development efforts.
NASA Technical Reports Server (NTRS)
Lawrence, Stella
1992-01-01
This paper is concerned with methods of measuring and developing quality software. Reliable flight and ground support software is a highly important factor in the successful operation of the space shuttle program. Reliability is probably the most important of the characteristics inherent in the concept of 'software quality'. It is the probability of failure free operation of a computer program for a specified time and environment.
The State of Software for Evolutionary Biology.
Darriba, Diego; Flouri, Tomáš; Stamatakis, Alexandros
2018-05-01
With Next Generation Sequencing data being routinely used, evolutionary biology is transforming into a computational science. Thus, researchers have to rely on a growing number of increasingly complex software. All widely used core tools in the field have grown considerably, in terms of the number of features as well as lines of code and consequently, also with respect to software complexity. A topic that has received little attention is the software engineering quality of widely used core analysis tools. Software developers appear to rarely assess the quality of their code, and this can have potential negative consequences for end-users. To this end, we assessed the code quality of 16 highly cited and compute-intensive tools mainly written in C/C++ (e.g., MrBayes, MAFFT, SweepFinder, etc.) and JAVA (BEAST) from the broader area of evolutionary biology that are being routinely used in current data analysis pipelines. Because, the software engineering quality of the tools we analyzed is rather unsatisfying, we provide a list of best practices for improving the quality of existing tools and list techniques that can be deployed for developing reliable, high quality scientific software from scratch. Finally, we also discuss journal as well as science policy and, more importantly, funding issues that need to be addressed for improving software engineering quality as well as ensuring support for developing new and maintaining existing software. Our intention is to raise the awareness of the community regarding software engineering quality issues and to emphasize the substantial lack of funding for scientific software development.
Sowunmi, Olaperi Yeside; Misra, Sanjay; Fernandez-Sanz, Luis; Crawford, Broderick; Soto, Ricardo
2016-01-01
The importance of quality assurance in the software development process cannot be overemphasized because its adoption results in high reliability and easy maintenance of the software system and other software products. Software quality assurance includes different activities such as quality control, quality management, quality standards, quality planning, process standardization and improvement amongst others. The aim of this work is to further investigate the software quality assurance practices of practitioners in Nigeria. While our previous work covered areas on quality planning, adherence to standardized processes and the inherent challenges, this work has been extended to include quality control, software process improvement and international quality standard organization membership. It also makes comparison based on a similar study carried out in Turkey. The goal is to generate more robust findings that can properly support decision making by the software community. The qualitative research approach, specifically, the use of questionnaire research instruments was applied to acquire data from software practitioners. In addition to the previous results, it was observed that quality assurance practices are quite neglected and this can be the cause of low patronage. Moreover, software practitioners are neither aware of international standards organizations or the required process improvement techniques; as such their claimed standards are not aligned to those of accredited bodies, and are only limited to their local experience and knowledge, which makes it questionable. The comparison with Turkey also yielded similar findings, making the results typical of developing countries. The research instrument used was tested for internal consistency using the Cronbach's alpha, and it was proved reliable. For the software industry in developing countries to grow strong and be a viable source of external revenue, software assurance practices have to be taken seriously because its effect is evident in the final product. Moreover, quality frameworks and tools which require minimum time and cost are highly needed in these countries.
The State of Software for Evolutionary Biology
Darriba, Diego; Flouri, Tomáš; Stamatakis, Alexandros
2018-01-01
Abstract With Next Generation Sequencing data being routinely used, evolutionary biology is transforming into a computational science. Thus, researchers have to rely on a growing number of increasingly complex software. All widely used core tools in the field have grown considerably, in terms of the number of features as well as lines of code and consequently, also with respect to software complexity. A topic that has received little attention is the software engineering quality of widely used core analysis tools. Software developers appear to rarely assess the quality of their code, and this can have potential negative consequences for end-users. To this end, we assessed the code quality of 16 highly cited and compute-intensive tools mainly written in C/C++ (e.g., MrBayes, MAFFT, SweepFinder, etc.) and JAVA (BEAST) from the broader area of evolutionary biology that are being routinely used in current data analysis pipelines. Because, the software engineering quality of the tools we analyzed is rather unsatisfying, we provide a list of best practices for improving the quality of existing tools and list techniques that can be deployed for developing reliable, high quality scientific software from scratch. Finally, we also discuss journal as well as science policy and, more importantly, funding issues that need to be addressed for improving software engineering quality as well as ensuring support for developing new and maintaining existing software. Our intention is to raise the awareness of the community regarding software engineering quality issues and to emphasize the substantial lack of funding for scientific software development. PMID:29385525
The NCC project: A quality management perspective
NASA Technical Reports Server (NTRS)
Lee, Raymond H.
1993-01-01
The Network Control Center (NCC) Project introduced the concept of total quality management (TQM) in mid-1990. The CSC project team established a program which focused on continuous process improvement in software development methodology and consistent deliveries of high quality software products for the NCC. The vision of the TQM program was to produce error free software. Specific goals were established to allow continuing assessment of the progress toward meeting the overall quality objectives. The total quality environment, now a part of the NCC Project culture, has become the foundation for continuous process improvement and has resulted in the consistent delivery of quality software products over the last three years.
Culture shock: Improving software quality
DOE Office of Scientific and Technical Information (OSTI.GOV)
de Jong, K.; Trauth, S.L.
1988-01-01
The concept of software quality can represent a significant shock to an individual who has been developing software for many years and who believes he or she has been doing a high quality job. The very idea that software includes lines of code and associated documentation is foreign and difficult to grasp, at best. Implementation of a software quality program hinges on the concept that software is a product whose quality needs improving. When this idea is introduced into a technical community that is largely ''self-taught'' and has been producing ''good'' software for some time, a fundamental understanding of themore » concepts associated with software is often weak. Software developers can react as if to say, ''What are you talking about. What do you mean I'm not doing a good job. I haven't gotten any complaints about my code yetexclamation'' Coupling such surprise and resentment with the shock that software really is a product and software quality concepts do exist, can fuel the volatility of these emotions. In this paper, we demonstrate that the concept of software quality can indeed pose a culture shock to developers. We also show that a ''typical'' quality assurance approach, that of imposing a standard and providing inspectors and auditors to assure its adherence, contributes to this shock and detracts from the very goal the approach should achieve. We offer an alternative, adopted through experience, to implement a software quality program: cooperative assistance. We show how cooperation, education, consultation and friendly assistance can overcome this culture shock. 3 refs.« less
Integrating automated support for a software management cycle into the TAME system
NASA Technical Reports Server (NTRS)
Sunazuka, Toshihiko; Basili, Victor R.
1989-01-01
Software managers are interested in the quantitative management of software quality, cost and progress. An integrated software management methodology, which can be applied throughout the software life cycle for any number purposes, is required. The TAME (Tailoring A Measurement Environment) methodology is based on the improvement paradigm and the goal/question/metric (GQM) paradigm. This methodology helps generate a software engineering process and measurement environment based on the project characteristics. The SQMAR (software quality measurement and assurance technology) is a software quality metric system and methodology applied to the development processes. It is based on the feed forward control principle. Quality target setting is carried out before the plan-do-check-action activities are performed. These methodologies are integrated to realize goal oriented measurement, process control and visual management. A metric setting procedure based on the GQM paradigm, a management system called the software management cycle (SMC), and its application to a case study based on NASA/SEL data are discussed. The expected effects of SMC are quality improvement, managerial cost reduction, accumulation and reuse of experience, and a highly visual management reporting system.
Verification and Validation in a Rapid Software Development Process
NASA Technical Reports Server (NTRS)
Callahan, John R.; Easterbrook, Steve M.
1997-01-01
The high cost of software production is driving development organizations to adopt more automated design and analysis methods such as rapid prototyping, computer-aided software engineering (CASE) tools, and high-level code generators. Even developers of safety-critical software system have adopted many of these new methods while striving to achieve high levels Of quality and reliability. While these new methods may enhance productivity and quality in many cases, we examine some of the risks involved in the use of new methods in safety-critical contexts. We examine a case study involving the use of a CASE tool that automatically generates code from high-level system designs. We show that while high-level testing on the system structure is highly desirable, significant risks exist in the automatically generated code and in re-validating releases of the generated code after subsequent design changes. We identify these risks and suggest process improvements that retain the advantages of rapid, automated development methods within the quality and reliability contexts of safety-critical projects.
Development and Application of New Quality Model for Software Projects
Karnavel, K.; Dillibabu, R.
2014-01-01
The IT industry tries to employ a number of models to identify the defects in the construction of software projects. In this paper, we present COQUALMO and its limitations and aim to increase the quality without increasing the cost and time. The computation time, cost, and effort to predict the residual defects are very high; this was overcome by developing an appropriate new quality model named the software testing defect corrective model (STDCM). The STDCM was used to estimate the number of remaining residual defects in the software product; a few assumptions and the detailed steps of the STDCM are highlighted. The application of the STDCM is explored in software projects. The implementation of the model is validated using statistical inference, which shows there is a significant improvement in the quality of the software projects. PMID:25478594
Development and application of new quality model for software projects.
Karnavel, K; Dillibabu, R
2014-01-01
The IT industry tries to employ a number of models to identify the defects in the construction of software projects. In this paper, we present COQUALMO and its limitations and aim to increase the quality without increasing the cost and time. The computation time, cost, and effort to predict the residual defects are very high; this was overcome by developing an appropriate new quality model named the software testing defect corrective model (STDCM). The STDCM was used to estimate the number of remaining residual defects in the software product; a few assumptions and the detailed steps of the STDCM are highlighted. The application of the STDCM is explored in software projects. The implementation of the model is validated using statistical inference, which shows there is a significant improvement in the quality of the software projects.
ERIC Educational Resources Information Center
Pfaffman, Jay
2008-01-01
Free/Open Source Software (FOSS) applications meet many of the software needs of high school science classrooms. In spite of the availability and quality of FOSS tools, they remain unknown to many teachers and utilized by fewer still. In a world where most software has restrictions on copying and use, FOSS is an anomaly, free to use and to…
Software Quality Control at Belle II
NASA Astrophysics Data System (ADS)
Ritter, M.; Kuhr, T.; Hauth, T.; Gebard, T.; Kristof, M.; Pulvermacher, C.;
2017-10-01
Over the last seven years the software stack of the next generation B factory experiment Belle II has grown to over one million lines of C++ and Python code, counting only the part included in offline software releases. There are several thousand commits to the central repository by about 100 individual developers per year. To keep a coherent software stack of high quality that it can be sustained and used efficiently for data acquisition, simulation, reconstruction, and analysis over the lifetime of the Belle II experiment is a challenge. A set of tools is employed to monitor the quality of the software and provide fast feedback to the developers. They are integrated in a machinery that is controlled by a buildbot master and automates the quality checks. The tools include different compilers, cppcheck, the clang static analyzer, valgrind memcheck, doxygen, a geometry overlap checker, a check for missing or extra library links, unit tests, steering file level tests, a sophisticated high-level validation suite, and an issue tracker. The technological development infrastructure is complemented by organizational means to coordinate the development.
Understanding Acceptance of Software Metrics--A Developer Perspective
ERIC Educational Resources Information Center
Umarji, Medha
2009-01-01
Software metrics are measures of software products and processes. Metrics are widely used by software organizations to help manage projects, improve product quality and increase efficiency of the software development process. However, metrics programs tend to have a high failure rate in organizations, and developer pushback is one of the sources…
SQA of finite element method (FEM) codes used for analyses of pit storage/transport packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russel, E.
1997-11-01
This report contains viewgraphs on the software quality assurance of finite element method codes used for analyses of pit storage and transport projects. This methodology utilizes the ISO 9000-3: Guideline for application of 9001 to the development, supply, and maintenance of software, for establishing well-defined software engineering processes to consistently maintain high quality management approaches.
Defect measurement and analysis of JPL ground software: a case study
NASA Technical Reports Server (NTRS)
Powell, John D.; Spagnuolo, John N., Jr.
2004-01-01
Ground software systems at JPL must meet high assurance standards while remaining on schedule due to relatively immovable launch dates for spacecraft that will be controlled by such systems. Toward this end, the Software Quality Improvement (SQI) project's Measurement and Benchmarking (M&B) team is collecting and analyzing defect data of JPL ground system software projects to build software defect prediction models. The aim of these models is to improve predictability with regard to software quality activities. Predictive models will quantitatively define typical trends for JPL ground systems as well as Critical Discriminators (CDs) to provide explanations for atypical deviations from the norm at JPL. CDs are software characteristics that can be estimated or foreseen early in a software project's planning. Thus, these CDs will assist in planning for the predicted degree to which software quality activities for a project are likely to deviation from the normal JPL ground system based on pasted experience across the lab.
Automated daily quality control analysis for mammography in a multi-unit imaging center.
Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli
2018-01-01
Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.
NASA Astrophysics Data System (ADS)
Pellegrin, F.; Jeram, B.; Haucke, J.; Feyrin, S.
2016-07-01
The paper describes the introduction of a new automatized build and test infrastructure, based on the open-source software Jenkins1, into the ESO Very Large Telescope control software to replace the preexisting in-house solution. A brief introduction to software quality practices is given, a description of the previous solution, the limitations of it and new upcoming requirements. Modifications required to adapt the new system are described, how these were implemented to current software and the results obtained. An overview on how the new system may be used in future projects is also presented.
Secure software practices among Malaysian software practitioners: An exploratory study
NASA Astrophysics Data System (ADS)
Mohamed, Shafinah Farvin Packeer; Baharom, Fauziah; Deraman, Aziz; Yahya, Jamaiah; Mohd, Haslina
2016-08-01
Secure software practices is increasingly gaining much importance among software practitioners and researchers due to the rise of computer crimes in the software industry. It has become as one of the determinant factors for producing high quality software. Even though its importance has been revealed, its current practice in the software industry is still scarce, particularly in Malaysia. Thus, an exploratory study is conducted among software practitioners in Malaysia to study their experiences and practices in the real-world projects. This paper discusses the findings from the study, which involved 93 software practitioners. Structured questionnaire is utilized for data collection purpose whilst statistical methods such as frequency, mean, and cross tabulation are used for data analysis. Outcomes from this study reveal that software practitioners are becoming increasingly aware on the importance of secure software practices, however, they lack of appropriate implementation, which could affect the quality of produced software.
[Use of Adobe Photoshop software in medical criminology].
Nikitin, S A; Demidov, I V
2000-01-01
Describes the method of comparative analysis of various objects in practical medical criminology and making of high-quality photographs with the use of Adobe Photoshop software. Options of the software needed for expert evaluations are enumerated.
xSDK Foundations: Toward an Extreme-scale Scientific Software Development Kit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heroux, Michael A.; Bartlett, Roscoe; Demeshko, Irina
Here, extreme-scale computational science increasingly demands multiscale and multiphysics formulations. Combining software developed by independent groups is imperative: no single team has resources for all predictive science and decision support capabilities. Scientific libraries provide high-quality, reusable software components for constructing applications with improved robustness and portability. However, without coordination, many libraries cannot be easily composed. Namespace collisions, inconsistent arguments, lack of third-party software versioning, and additional difficulties make composition costly. The Extreme-scale Scientific Software Development Kit (xSDK) defines community policies to improve code quality and compatibility across independently developed packages (hypre, PETSc, SuperLU, Trilinos, and Alquimia) and provides a foundationmore » for addressing broader issues in software interoperability, performance portability, and sustainability. The xSDK provides turnkey installation of member software and seamless combination of aggregate capabilities, and it marks first steps toward extreme-scale scientific software ecosystems from which future applications can be composed rapidly with assured quality and scalability.« less
xSDK Foundations: Toward an Extreme-scale Scientific Software Development Kit
Heroux, Michael A.; Bartlett, Roscoe; Demeshko, Irina; ...
2017-03-01
Here, extreme-scale computational science increasingly demands multiscale and multiphysics formulations. Combining software developed by independent groups is imperative: no single team has resources for all predictive science and decision support capabilities. Scientific libraries provide high-quality, reusable software components for constructing applications with improved robustness and portability. However, without coordination, many libraries cannot be easily composed. Namespace collisions, inconsistent arguments, lack of third-party software versioning, and additional difficulties make composition costly. The Extreme-scale Scientific Software Development Kit (xSDK) defines community policies to improve code quality and compatibility across independently developed packages (hypre, PETSc, SuperLU, Trilinos, and Alquimia) and provides a foundationmore » for addressing broader issues in software interoperability, performance portability, and sustainability. The xSDK provides turnkey installation of member software and seamless combination of aggregate capabilities, and it marks first steps toward extreme-scale scientific software ecosystems from which future applications can be composed rapidly with assured quality and scalability.« less
Improving the quality of EHR recording in primary care: a data quality feedback tool.
van der Bij, Sjoukje; Khan, Nasra; Ten Veen, Petra; de Bakker, Dinny H; Verheij, Robert A
2017-01-01
Electronic health record (EHR) data are used to exchange information among health care providers. For this purpose, the quality of the data is essential. We developed a data quality feedback tool that evaluates differences in EHR data quality among practices and software packages as part of a larger intervention. The tool was applied in 92 practices in the Netherlands using different software packages. Practices received data quality feedback in 2010 and 2012. We observed large differences in the quality of recording. For example, the percentage of episodes of care that had a meaningful diagnostic code ranged from 30% to 100%. Differences were highly related to the software package. A year after the first measurement, the quality of recording had improved significantly and differences decreased, with 67% of the physicians indicating that they had actively changed their recording habits based on the results of the first measurement. About 80% found the feedback helpful in pinpointing recording problems. One of the software vendors made changes in functionality as a result of the feedback. Our EHR data quality feedback tool is capable of highlighting differences among practices and software packages. As such, it also stimulates improvements. As substantial variability in recording is related to the software package, our study strengthens the evidence that data quality can be improved substantially by standardizing the functionalities of EHR software packages. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Constraint-Driven Software Design: An Escape from the Waterfall Model.
ERIC Educational Resources Information Center
de Hoog, Robert; And Others
1994-01-01
Presents the principles of a development methodology for software design based on a nonlinear, product-driven approach that integrates quality aspects. Two examples are given to show that the flexibility needed for building high quality systems leads to integrated development environments in which methodology, product, and tools are closely…
Supporting Early Math--Rationales and Requirements for High Quality Software
ERIC Educational Resources Information Center
Haake, Magnus; Husain, Layla; Gulz, Agneta
2015-01-01
There is substantial evidence that preschooler's performance in early math is highly correlated to math performance throughout school as well as academic skills in general. One way to help children attain early math skills is by using targeted educational software and the paper discusses potential gains of using such software to support early math…
Organizational management practices for achieving software process improvement
NASA Technical Reports Server (NTRS)
Kandt, Ronald Kirk
2004-01-01
The crisis in developing software has been known for over thirty years. Problems that existed in developing software in the early days of computing still exist today. These problems include the delivery of low-quality products, actual development costs that exceed expected development costs, and actual development time that exceeds expected development time. Several solutions have been offered to overcome out inability to deliver high-quality software, on-time and within budget. One of these solutions involves software process improvement. However, such efforts often fail because of organizational management issues. This paper discusses business practices that organizations should follow to improve their chances of initiating and sustaining successful software process improvement efforts.
NASA Technical Reports Server (NTRS)
1992-01-01
This standard specifies the software assurance program for the provider of software. It also delineates the assurance activities for the provider and the assurance data that are to be furnished by the provider to the acquirer. In any software development effort, the provider is the entity or individual that actually designs, develops, and implements the software product, while the acquirer is the entity or individual who specifies the requirements and accepts the resulting products. This standard specifies at a high level an overall software assurance program for software developed for and by NASA. Assurance includes the disciplines of quality assurance, quality engineering, verification and validation, nonconformance reporting and corrective action, safety assurance, and security assurance. The application of these disciplines during a software development life cycle is called software assurance. Subsequent lower-level standards will specify the specific processes within these disciplines.
Software IV and V Research Priorities and Applied Program Accomplishments Within NASA
NASA Technical Reports Server (NTRS)
Blazy, Louis J.
2000-01-01
The mission of this research is to be world-class creators and facilitators of innovative, intelligent, high performance, reliable information technologies that enable NASA missions to (1) increase software safety and quality through error avoidance, early detection and resolution of errors, by utilizing and applying empirically based software engineering best practices; (2) ensure customer software risks are identified and/or that requirements are met and/or exceeded; (3) research, develop, apply, verify, and publish software technologies for competitive advantage and the advancement of science; and (4) facilitate the transfer of science and engineering data, methods, and practices to NASA, educational institutions, state agencies, and commercial organizations. The goals are to become a national Center Of Excellence (COE) in software and system independent verification and validation, and to become an international leading force in the field of software engineering for improving the safety, quality, reliability, and cost performance of software systems. This project addresses the following problems: Ensure safety of NASA missions, ensure requirements are met, minimize programmatic and technological risks of software development and operations, improve software quality, reduce costs and time to delivery, and improve the science of software engineering
Functional description of the ISIS system
NASA Technical Reports Server (NTRS)
Berman, W. J.
1979-01-01
Development of software for avionic and aerospace applications (flight software) is influenced by a unique combination of factors which includes: (1) length of the life cycle of each project; (2) necessity for cooperation between the aerospace industry and NASA; (3) the need for flight software that is highly reliable; (4) the increasing complexity and size of flight software; and (5) the high quality of the programmers and the tightening of project budgets. The interactive software invocation system (ISIS) which is described is designed to overcome the problems created by this combination of factors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Roscoe A; Heroux, Dr. Michael A; Willenbring, James
2012-01-01
Software lifecycles are becoming an increasingly important issue for computational science & engineering (CSE) software. The process by which a piece of CSE software begins life as a set of research requirements and then matures into a trusted high-quality capability is both commonplace and extremely challenging. Although an implicit lifecycle is obviously being used in any effort, the challenges of this process--respecting the competing needs of research vs. production--cannot be overstated. Here we describe a proposal for a well-defined software lifecycle process based on modern Lean/Agile software engineering principles. What we propose is appropriate for many CSE software projects thatmore » are initially heavily focused on research but also are expected to eventually produce usable high-quality capabilities. The model is related to TriBITS, a build, integration and testing system, which serves as a strong foundation for this lifecycle model, and aspects of this lifecycle model are ingrained in the TriBITS system. Indeed this lifecycle process, if followed, will enable large-scale sustainable integration of many complex CSE software efforts across several institutions.« less
Factors in Software Quality. Volume I. Concepts and Definitions of Software Quality
1977-11-01
FLEXIBILITY COMPLEXITY EXPANDABILITY PRECISION DOCUMENTATION TOLERANCE REPAIRABILITY COMPATABIL ITY SERVICEABILITY 2-4 AiI1I~3~I!-T A1 11 NI AIiB 9l 0...applications. Several standard documents are required by DOD/AF’ regulations . The following references were used to compile the rFpnge of documents...documents are specified by the AF regulations or SPO-local regulations listed above. Each ot the document types for a long life/high cost software
Design Aids for Real-Time Systems (DARTS)
NASA Technical Reports Server (NTRS)
Szulewski, P. A.
1982-01-01
Design-Aids for Real-Time Systems (DARTS) is a tool that assists in defining embedded computer systems through tree structured graphics, military standard documentation support, and various analyses including automated Software Science parameter counting and metrics calculation. These analyses provide both static and dynamic design quality feedback which can potentially aid in producing efficient, high quality software systems.
The Legacy of Space Shuttle Flight Software
NASA Technical Reports Server (NTRS)
Hickey, Christopher J.; Loveall, James B.; Orr, James K.; Klausman, Andrew L.
2011-01-01
The initial goals of the Space Shuttle Program required that the avionics and software systems blaze new trails in advancing avionics system technology. Many of the requirements placed on avionics and software were accomplished for the first time on this program. Examples include comprehensive digital fly-by-wire technology, use of a digital databus for flight critical functions, fail operational/fail safe requirements, complex automated redundancy management, and the use of a high-order software language for flight software development. In order to meet the operational and safety goals of the program, the Space Shuttle software had to be extremely high quality, reliable, robust, reconfigurable and maintainable. To achieve this, the software development team evolved a software process focused on continuous process improvement and defect elimination that consistently produced highly predictable and top quality results, providing software managers the confidence needed to sign each Certificate of Flight Readiness (COFR). This process, which has been appraised at Capability Maturity Model (CMM)/Capability Maturity Model Integration (CMMI) Level 5, has resulted in one of the lowest software defect rates in the industry. This paper will present an overview of the evolution of the Primary Avionics Software System (PASS) project and processes over thirty years, an argument for strong statistical control of software processes with examples, an overview of the success story for identifying and driving out errors before flight, a case study of the few significant software issues and how they were either identified before flight or slipped through the process onto a flight vehicle, and identification of the valuable lessons learned over the life of the project.
Khomtchouk, Bohdan B; Van Booven, Derek J; Wahlestedt, Claes
2014-01-01
The graphical visualization of gene expression data using heatmaps has become an integral component of modern-day medical research. Heatmaps are used extensively to plot quantitative differences in gene expression levels, such as those measured with RNAseq and microarray experiments, to provide qualitative large-scale views of the transcriptonomic landscape. Creating high-quality heatmaps is a computationally intensive task, often requiring considerable programming experience, particularly for customizing features to a specific dataset at hand. Software to create publication-quality heatmaps is developed with the R programming language, C++ programming language, and OpenGL application programming interface (API) to create industry-grade high performance graphics. We create a graphical user interface (GUI) software package called HeatmapGenerator for Windows OS and Mac OS X as an intuitive, user-friendly alternative to researchers with minimal prior coding experience to allow them to create publication-quality heatmaps using R graphics without sacrificing their desired level of customization. The simplicity of HeatmapGenerator is that it only requires the user to upload a preformatted input file and download the publicly available R software language, among a few other operating system-specific requirements. Advanced features such as color, text labels, scaling, legend construction, and even database storage can be easily customized with no prior programming knowledge. We provide an intuitive and user-friendly software package, HeatmapGenerator, to create high-quality, customizable heatmaps generated using the high-resolution color graphics capabilities of R. The software is available for Microsoft Windows and Apple Mac OS X. HeatmapGenerator is released under the GNU General Public License and publicly available at: http://sourceforge.net/projects/heatmapgenerator/. The Mac OS X direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_MAC_OSX.tar.gz/download. The Windows OS direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_WINDOWS.zip/download.
beta-Aminoalcohols as Potential Reactivators of Aged Sarin-/Soman-Inhibited Acetylcholinesterase
2017-02-08
This approach includes high - quality quantum mechanical/molecular mechanical calcula- tions, providing reliable reactivation steps and energetics...I. V. Khavrutskii Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced...b] Dr. A. Wallqvist Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced
Automating Software Design Metrics.
1984-02-01
INTRODUCTION 1 ", ... 0..1 1.2 HISTORICAL PERSPECTIVE High quality software is of interest to both the software engineering com- munity and its users. As...contributions of many other software engineering efforts, most notably [MCC 77] and [Boe 83b], which have defined and refined a framework for quantifying...AUTOMATION OF DESIGN METRICS Software metrics can be useful within the context of an integrated soft- ware engineering environment. The purpose of this
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minana, Molly A.; Sturtevant, Judith E.; Heaphy, Robert
2005-01-01
The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. Quality is defined in DOE/AL Quality Criteria (QC-1) as conformance to customer requirements and expectations. This quality plan defines the ASC program software quality practices and provides mappings of these practices to the SNL Corporate Process Requirements (CPR 1.3.2 and CPR 1.3.6) and the Department of Energy (DOE) document, ASCI Software Quality Engineering: Goals, Principles, and Guidelines (GP&G). This quality plan identifies ASC management andmore » software project teams' responsibilities for cost-effective software engineering quality practices. The SNL ASC Software Quality Plan establishes the signatories commitment to improving software products by applying cost-effective software engineering quality practices. This document explains the project teams opportunities for tailoring and implementing the practices; enumerates the practices that compose the development of SNL ASC's software products; and includes a sample assessment checklist that was developed based upon the practices in this document.« less
Future of Software Engineering Standards
NASA Technical Reports Server (NTRS)
Poon, Peter T.
1997-01-01
In the new millennium, software engineering standards are expected to continue to influence the process of producing software-intensive systems which are cost-effetive and of high quality. These sytems may range from ground and flight systems used for planetary exploration to educational support systems used in schools as well as consumer-oriented systems.
ERIC Educational Resources Information Center
National Academy of Sciences - National Research Council, Washington, DC.
The Panel on Guidelines for Statistical Software was organized in 1990 to document, assess, and prioritize problem areas regarding quality and reliability of statistical software; present prototype guidelines in high priority areas; and make recommendations for further research and discussion. This document provides the following papers presented…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turgeon, Jennifer L.; Minana, Molly A.; Hackney, Patricia
2009-01-01
The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. Quality is defined in the US Department of Energy/National Nuclear Security Agency (DOE/NNSA) Quality Criteria, Revision 10 (QC-1) as 'conformance to customer requirements and expectations'. This quality plan defines the SNL ASC Program software quality engineering (SQE) practices and provides a mapping of these practices to the SNL Corporate Process Requirement (CPR) 001.3.6; 'Corporate Software Engineering Excellence'. This plan also identifies ASC management's and themore » software project teams responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals. This SNL ASC Software Quality Plan establishes the signatories commitments to improving software products by applying cost-effective SQE practices. This plan enumerates the SQE practices that comprise the development of SNL ASC's software products and explains the project teams opportunities for tailoring and implementing the practices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sturtevant, Judith E.; Heaphy, Robert; Hodges, Ann Louise
2006-09-01
The purpose of the Sandia National Laboratories Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. The plan defines the ASC program software quality practices and provides mappings of these practices to Sandia Corporate Requirements CPR 1.3.2 and 1.3.6 and to a Department of Energy document, ASCI Software Quality Engineering: Goals, Principles, and Guidelines. This document also identifies ASC management and software project teams responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals.
Analysis of quality raw data of second generation sequencers with Quality Assessment Software.
Ramos, Rommel Tj; Carneiro, Adriana R; Baumbach, Jan; Azevedo, Vasco; Schneider, Maria Pc; Silva, Artur
2011-04-18
Second generation technologies have advantages over Sanger; however, they have resulted in new challenges for the genome construction process, especially because of the small size of the reads, despite the high degree of coverage. Independent of the program chosen for the construction process, DNA sequences are superimposed, based on identity, to extend the reads, generating contigs; mismatches indicate a lack of homology and are not included. This process improves our confidence in the sequences that are generated. We developed Quality Assessment Software, with which one can review graphs showing the distribution of quality values from the sequencing reads. This software allow us to adopt more stringent quality standards for sequence data, based on quality-graph analysis and estimated coverage after applying the quality filter, providing acceptable sequence coverage for genome construction from short reads. Quality filtering is a fundamental step in the process of constructing genomes, as it reduces the frequency of incorrect alignments that are caused by measuring errors, which can occur during the construction process due to the size of the reads, provoking misassemblies. Application of quality filters to sequence data, using the software Quality Assessment, along with graphing analyses, provided greater precision in the definition of cutoff parameters, which increased the accuracy of genome construction.
Evaluating Predictive Models of Software Quality
NASA Astrophysics Data System (ADS)
Ciaschini, V.; Canaparo, M.; Ronchieri, E.; Salomoni, D.
2014-06-01
Applications from High Energy Physics scientific community are constantly growing and implemented by a large number of developers. This implies a strong churn on the code and an associated risk of faults, which is unavoidable as long as the software undergoes active evolution. However, the necessities of production systems run counter to this. Stability and predictability are of paramount importance; in addition, a short turn-around time for the defect discovery-correction-deployment cycle is required. A way to reconcile these opposite foci is to use a software quality model to obtain an approximation of the risk before releasing a program to only deliver software with a risk lower than an agreed threshold. In this article we evaluated two quality predictive models to identify the operational risk and the quality of some software products. We applied these models to the development history of several EMI packages with intent to discover the risk factor of each product and compare it with its real history. We attempted to determine if the models reasonably maps reality for the applications under evaluation, and finally we concluded suggesting directions for further studies.
Chen, Wenjin; Wong, Chung; Vosburgh, Evan; Levine, Arnold J; Foran, David J; Xu, Eugenia Y
2014-07-08
The increasing number of applications of three-dimensional (3D) tumor spheroids as an in vitro model for drug discovery requires their adaptation to large-scale screening formats in every step of a drug screen, including large-scale image analysis. Currently there is no ready-to-use and free image analysis software to meet this large-scale format. Most existing methods involve manually drawing the length and width of the imaged 3D spheroids, which is a tedious and time-consuming process. This study presents a high-throughput image analysis software application - SpheroidSizer, which measures the major and minor axial length of the imaged 3D tumor spheroids automatically and accurately; calculates the volume of each individual 3D tumor spheroid; then outputs the results in two different forms in spreadsheets for easy manipulations in the subsequent data analysis. The main advantage of this software is its powerful image analysis application that is adapted for large numbers of images. It provides high-throughput computation and quality-control workflow. The estimated time to process 1,000 images is about 15 min on a minimally configured laptop, or around 1 min on a multi-core performance workstation. The graphical user interface (GUI) is also designed for easy quality control, and users can manually override the computer results. The key method used in this software is adapted from the active contour algorithm, also known as Snakes, which is especially suitable for images with uneven illumination and noisy background that often plagues automated imaging processing in high-throughput screens. The complimentary "Manual Initialize" and "Hand Draw" tools provide the flexibility to SpheroidSizer in dealing with various types of spheroids and diverse quality images. This high-throughput image analysis software remarkably reduces labor and speeds up the analysis process. Implementing this software is beneficial for 3D tumor spheroids to become a routine in vitro model for drug screens in industry and academia.
Modernization of software quality assurance
NASA Technical Reports Server (NTRS)
Bhaumik, Gokul
1988-01-01
The customers satisfaction depends not only on functional performance, it also depends on the quality characteristics of the software products. An examination of this quality aspect of software products will provide a clear, well defined framework for quality assurance functions, which improve the life-cycle activities of software development. Software developers must be aware of the following aspects which have been expressed by many quality experts: quality cannot be added on; the level of quality built into a program is a function of the quality attributes employed during the development process; and finally, quality must be managed. These concepts have guided our development of the following definition for a Software Quality Assurance function: Software Quality Assurance is a formal, planned approach of actions designed to evaluate the degree of an identifiable set of quality attributes present in all software systems and their products. This paper is an explanation of how this definition was developed and how it is used.
Software archeology: a case study in software quality assurance and design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macdonald, John M; Lloyd, Jane A; Turner, Cameron J
2009-01-01
Ideally, quality is designed into software, just as quality is designed into hardware. However, when dealing with legacy systems, demonstrating that the software meets required quality standards may be difficult to achieve. As the need to demonstrate the quality of existing software was recognized at Los Alamos National Laboratory (LANL), an effort was initiated to uncover and demonstrate that legacy software met the required quality standards. This effort led to the development of a reverse engineering approach referred to as software archaeology. This paper documents the software archaeology approaches used at LANL to document legacy software systems. A case studymore » for the Robotic Integrated Packaging System (RIPS) software is included.« less
Newman, Eric D; Lerch, Virginia; Billet, Jon; Berger, Andrea; Kirchner, H Lester
2015-04-01
Electronic health records (EHRs) are not optimized for chronic disease management. To improve the quality of care for patients with rheumatic disease, we developed electronic data capture, aggregation, display, and documentation software. The software integrated and reassembled information from the patient (via a touchscreen questionnaire), nurse, physician, and EHR into a series of actionable views. Core functions included trends over time, rheumatology-related demographics, and documentation for patient and provider. Quality measures collected included patient-reported outcomes, disease activity, and function. The software was tested and implemented in 3 rheumatology departments, and integrated into routine care delivery. Post-implementation evaluation measured adoption, efficiency, productivity, and patient perception. Over 2 years, 6,725 patients completed 19,786 touchscreen questionnaires. The software was adopted for use by 86% of patients and rheumatologists. Chart review and documentation time trended downward, and productivity increased by 26%. Patient satisfaction, activation, and adherence remained unchanged, although pre-implementation values were high. A strong correlation was seen between use of the software and disease control (weighted Pearson's correlation coefficient 0.5927, P = 0.0095), and a relative increase in patients with low disease activity of 3% per quarter was noted. We describe innovative software that aggregates, stores, and displays information vital to improving the quality of care for patients with chronic rheumatic disease. The software was well-adopted by patients and providers. Post-implementation, significant improvements in quality of care, efficiency of care, and productivity were demonstrated. Copyright © 2015 by the American College of Rheumatology.
Software Quality Perceptions of Stakeholders Involved in the Software Development Process
ERIC Educational Resources Information Center
Padmanabhan, Priya
2013-01-01
Software quality is one of the primary determinants of project management success. Stakeholders involved in software development widely agree that quality is important (Barney and Wohlin 2009). However, they may differ on what constitutes software quality, and which of its attributes are more important than others. Although, software quality…
Cost Effective Development of Usable Systems: Gaps between HCI and Software Architecture Design
NASA Astrophysics Data System (ADS)
Folmer, Eelke; Bosch, Jan
A software product with poor usability is likely to fail in a highly competitive market; therefore software developing organizations are paying more and more attention to ensuring the usability of their software. Practice, however, shows that product quality (which includes usability among others) is not that high as it could be. Studies of software projects (Pressman, 2001) reveal that organizations spend a relative large amount of money and effort on fixing usability problems during late stage development. Some of these problems could have been detected and fixed much earlier. This avoidable rework leads to high costs and because during development different tradeoffs have to be made, for example between cost and quality leads to systems with less than optimal usability. This problem has been around for a couple of decades especially after software engineering (SE) and human computer interaction (HCI) became disciplines on their own. While both disciplines developed themselves, several gaps appeared which are now receiving increased attention in research literature. Major gaps of understanding, both between suggested practice and how software is actually developed in industry, but also between the best practices of each of the fields have been identified (Carrol et al, 1994, Bass et al, 2001, Folmer and Bosch, 2002). In addition, there are gaps in the fields of differing terminology, concepts, education, and methods.
A Guideline of Using Case Method in Software Engineering Courses
ERIC Educational Resources Information Center
Zainal, Dzulaiha Aryanee Putri; Razali, Rozilawati; Shukur, Zarina
2014-01-01
Software Engineering (SE) education has been reported to fall short in producing high quality software engineers. In seeking alternative solutions, Case Method (CM) is regarded as having potential to solve the issue. CM is a teaching and learning (T&L) method that has been found to be effective in Social Science education. In principle,…
[Research progress of probe design software of oligonucleotide microarrays].
Chen, Xi; Wu, Zaoquan; Liu, Zhengchun
2014-02-01
DNA microarray has become an essential medical genetic diagnostic tool for its high-throughput, miniaturization and automation. The design and selection of oligonucleotide probes are critical for preparing gene chips with high quality. Several sets of probe design software have been developed and are available to perform this work now. Every set of the software aims to different target sequences and shows different advantages and limitations. In this article, the research and development of these sets of software are reviewed in line with three main criteria, including specificity, sensitivity and melting temperature (Tm). In addition, based on the experimental results from literatures, these sets of software are classified according to their applications. This review will be helpful for users to choose an appropriate probe-design software. It will also reduce the costs of microarrays, improve the application efficiency of microarrays, and promote both the research and development (R&D) and commercialization of high-performance probe design software.
Software cost/resource modeling: Software quality tradeoff measurement
NASA Technical Reports Server (NTRS)
Lawler, R. W.
1980-01-01
A conceptual framework for treating software quality from a total system perspective is developed. Examples are given to show how system quality objectives may be allocated to hardware and software; to illustrate trades among quality factors, both hardware and software, to achieve system performance objectives; and to illustrate the impact of certain design choices on software functionality.
Automated Theorem Proving in High-Quality Software Design
NASA Technical Reports Server (NTRS)
Schumann, Johann; Swanson, Keith (Technical Monitor)
2001-01-01
The amount and complexity of software developed during the last few years has increased tremendously. In particular, programs are being used more and more in embedded systems (from car-brakes to plant-control). Many of these applications are safety-relevant, i.e. a malfunction of hardware or software can cause severe damage or loss. Tremendous risks are typically present in the area of aviation, (nuclear) power plants or (chemical) plant control. Here, even small problems can lead to thousands of casualties and huge financial losses. Large financial risks also exist when computer systems are used in the area of telecommunication (telephone, electronic commerce) or space exploration. Computer applications in this area are not only subject to safety considerations, but also security issues are important. All these systems must be designed and developed to guarantee high quality with respect to safety and security. Even in an industrial setting which is (or at least should be) aware of the high requirements in Software Engineering, many incidents occur. For example, the Warshaw Airbus crash, was caused by an incomplete requirements specification. Uncontrolled reuse of an Ariane 4 software module was the reason for the Ariane 5 disaster. Some recent incidents in the telecommunication area, like illegal "cloning" of smart-cards of D2GSM handies, or the extraction of (secret) passwords from German T-online users show that also in this area serious flaws can happen. Due to the inherent complexity of computer systems, most authors claim that only a rigorous application of formal methods in all stages of the software life cycle can ensure high quality of the software and lead to real safe and secure systems. In this paper, we will have a look, in how far automated theorem proving can contribute to a more widespread application of formal methods and their tools, and what automated theorem provers (ATPs) must provide in order to be useful.
1992-06-01
presents the concept of software Total Quality Management (TQM) which focuses on the entire process of software acquisition, as a partial solution to...software TQM can be applied to software acquisition. Software Development, Software Acquisition, Total Quality management (TQM), Army Tactical Missile
The Effects of Development Team Skill on Software Product Quality
NASA Technical Reports Server (NTRS)
Beaver, Justin M.; Schiavone, Guy A.
2006-01-01
This paper provides an analysis of the effect of the skill/experience of the software development team on the quality of the final software product. A method for the assessment of software development team skill and experience is proposed, and was derived from a workforce management tool currently in use by the National Aeronautics and Space Administration. Using data from 26 smallscale software development projects, the team skill measures are correlated to 5 software product quality metrics from the ISO/IEC 9126 Software Engineering Product Quality standard. in the analysis of the results, development team skill is found to be a significant factor in the adequacy of the design and implementation. In addition, the results imply that inexperienced software developers are tasked with responsibilities ill-suited to their skill level, and thus have a significant adverse effect on the quality of the software product. Keywords: software quality, development skill, software metrics
Automated Reuse of Scientific Subroutine Libraries through Deductive Synthesis
NASA Technical Reports Server (NTRS)
Lowry, Michael R.; Pressburger, Thomas; VanBaalen, Jeffrey; Roach, Steven
1997-01-01
Systematic software construction offers the potential of elevating software engineering from an art-form to an engineering discipline. The desired result is more predictable software development leading to better quality and more maintainable software. However, the overhead costs associated with the formalisms, mathematics, and methods of systematic software construction have largely precluded their adoption in real-world software development. In fact, many mainstream software development organizations, such as Microsoft, still maintain a predominantly oral culture for software development projects; which is far removed from a formalism-based culture for software development. An exception is the limited domain of safety-critical software, where the high-assuiance inherent in systematic software construction justifies the additional cost. We believe that systematic software construction will only be adopted by mainstream software development organization when the overhead costs have been greatly reduced. Two approaches to cost mitigation are reuse (amortizing costs over many applications) and automation. For the last four years, NASA Ames has funded the Amphion project, whose objective is to automate software reuse through techniques from systematic software construction. In particular, deductive program synthesis (i.e., program extraction from proofs) is used to derive a composition of software components (e.g., subroutines) that correctly implements a specification. The construction of reuse libraries of software components is the standard software engineering solution for improving software development productivity and quality.
A Systematic Process for Developing High Quality SaaS Cloud Services
NASA Astrophysics Data System (ADS)
La, Hyun Jung; Kim, Soo Dong
Software-as-a-Service (SaaS) is a type of cloud service which provides software functionality through Internet. Its benefits are well received in academia and industry. To fully utilize the benefits, there should be effective methodologies to support the development of SaaS services which provide high reusability and applicability. Conventional approaches such as object-oriented methods do not effectively support SaaS-specific engineering activities such as modeling common features, variability, and designing quality services. In this paper, we present a systematic process for developing high quality SaaS and highlight the essentiality of commonality and variability (C&V) modeling to maximize the reusability. We first define criteria for designing the process model and provide a theoretical foundation for SaaS; its meta-model and C&V model. We clarify the notion of commonality and variability in SaaS, and propose a SaaS development process which is accompanied with engineering instructions. Using the proposed process, SaaS services with high quality can be effectively developed.
A Framework of the Use of Information in Software Testing
ERIC Educational Resources Information Center
Kaveh, Payman
2010-01-01
With the increasing role that software systems play in our daily lives, software quality has become extremely important. Software quality is impacted by the efficiency of the software testing process. There are a growing number of software testing methodologies, models, and initiatives to satisfy the need to improve software quality. The main…
Oliveira, M; Lopez, G; Geambastiani, P; Ubeda, C
2018-05-01
A quality assurance (QA) program is a valuable tool for the continuous production of optimal quality images. The aim of this paper is to assess a newly developed automatic computer software for image quality (IR) evaluation in fluoroscopy X-ray systems. Test object images were acquired using one fluoroscopy system, Siemens Axiom Artis model (Siemens AG, Medical Solutions Erlangen, Germany). The software was developed as an ImageJ plugin. Two image quality parameters were assessed: high-contrast spatial resolution (HCSR) and signal-to-noise ratio (SNR). The time between manual and automatic image quality assessment procedures were compared. The paired t-test was used to assess the data. p Values of less than 0.05 were considered significant. The Fluoro-QC software generated faster IQ evaluation results (mean = 0.31 ± 0.08 min) than manual procedure (mean = 4.68 ± 0.09 min). The mean difference between techniques was 4.36 min. Discrepancies were identified in the region of interest (ROI) areas drawn manually with evidence of user dependence. The new software presented the results of two tests (HCSR = 3.06, SNR = 5.17) and also collected information from the DICOM header. Significant differences were not identified between manual and automatic measures of SNR (p value = 0.22) and HCRS (p value = 0.46). The Fluoro-QC software is a feasible, fast and free to use method for evaluating imaging quality parameters on fluoroscopy systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Software Quality Assurance Metrics
NASA Technical Reports Server (NTRS)
McRae, Kalindra A.
2004-01-01
Software Quality Assurance (SQA) is a planned and systematic set of activities that ensures conformance of software life cycle processes and products conform to requirements, standards and procedures. In software development, software quality means meeting requirements and a degree of excellence and refinement of a project or product. Software Quality is a set of attributes of a software product by which its quality is described and evaluated. The set of attributes includes functionality, reliability, usability, efficiency, maintainability, and portability. Software Metrics help us understand the technical process that is used to develop a product. The process is measured to improve it and the product is measured to increase quality throughout the life cycle of software. Software Metrics are measurements of the quality of software. Software is measured to indicate the quality of the product, to assess the productivity of the people who produce the product, to assess the benefits derived from new software engineering methods and tools, to form a baseline for estimation, and to help justify requests for new tools or additional training. Any part of the software development can be measured. If Software Metrics are implemented in software development, it can save time, money, and allow the organization to identify the caused of defects which have the greatest effect on software development. The summer of 2004, I worked with Cynthia Calhoun and Frank Robinson in the Software Assurance/Risk Management department. My task was to research and collect, compile, and analyze SQA Metrics that have been used in other projects that are not currently being used by the SA team and report them to the Software Assurance team to see if any metrics can be implemented in their software assurance life cycle process.
NASA Astrophysics Data System (ADS)
Martin, L.; Schatalov, M.; Hagner, M.; Goltz, U.; Maibaum, O.
Today's software for aerospace systems typically is very complex. This is due to the increasing number of features as well as the high demand for safety, reliability, and quality. This complexity also leads to significant higher software development costs. To handle the software complexity, a structured development process is necessary. Additionally, compliance with relevant standards for quality assurance is a mandatory concern. To assure high software quality, techniques for verification are necessary. Besides traditional techniques like testing, automated verification techniques like model checking become more popular. The latter examine the whole state space and, consequently, result in a full test coverage. Nevertheless, despite the obvious advantages, this technique is rarely yet used for the development of aerospace systems. In this paper, we propose a tool-supported methodology for the development and formal verification of safety-critical software in the aerospace domain. The methodology relies on the V-Model and defines a comprehensive work flow for model-based software development as well as automated verification in compliance to the European standard series ECSS-E-ST-40C. Furthermore, our methodology supports the generation and deployment of code. For tool support we use the tool SCADE Suite (Esterel Technology), an integrated design environment that covers all the requirements for our methodology. The SCADE Suite is well established in avionics and defense, rail transportation, energy and heavy equipment industries. For evaluation purposes, we apply our approach to an up-to-date case study of the TET-1 satellite bus. In particular, the attitude and orbit control software is considered. The behavioral models for the subsystem are developed, formally verified, and optimized.
NASA Technical Reports Server (NTRS)
Lee, Pen-Nan
1991-01-01
Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.
NASA Astrophysics Data System (ADS)
Mubarok, S.; Lubis, L. E.; Pawiro, S. A.
2016-03-01
Compromise between radiation dose and image quality is essential in the use of CT imaging. CT dose index (CTDI) is currently the primary dosimetric formalisms in CT scan, while the low and high contrast resolutions are aspects indicating the image quality. This study was aimed to estimate CTDIvol and image quality measures through a range of exposure parameters variation. CTDI measurements were performed using PMMA (polymethyl methacrylate) phantom of 16 cm diameter, while the image quality test was conducted by using catphan ® 600. CTDI measurements were carried out according to IAEA TRS 457 protocol using axial scan mode, under varied parameters of tube voltage, collimation or slice thickness, and tube current. Image quality test was conducted accordingly under the same exposure parameters with CTDI measurements. An Android™ based software was also result of this study. The software was designed to estimate the value of CTDIvol with maximum difference compared to actual CTDIvol measurement of 8.97%. Image quality can also be estimated through CNR parameter with maximum difference to actual CNR measurement of 21.65%.
SWiFT Software Quality Assurance Plan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berg, Jonathan Charles
This document describes the software development practice areas and processes which contribute to the ability of SWiFT software developers to provide quality software. These processes are designed to satisfy the requirements set forth by the Sandia Software Quality Assurance Program (SSQAP). APPROVALS SWiFT Software Quality Assurance Plan (SAND2016-0765) approved by: Department Manager SWiFT Site Lead Dave Minster (6121) Date Jonathan White (6121) Date SWiFT Controls Engineer Jonathan Berg (6121) Date CHANGE HISTORY Issue Date Originator(s) Description A 2016/01/27 Jon Berg (06121) Initial release of the SWiFT Software Quality Assurance Plan
Pragmatic quality metrics for evolutionary software development models
NASA Technical Reports Server (NTRS)
Royce, Walker
1990-01-01
Due to the large number of product, project, and people parameters which impact large custom software development efforts, measurement of software product quality is a complex undertaking. Furthermore, the absolute perspective from which quality is measured (customer satisfaction) is intangible. While we probably can't say what the absolute quality of a software product is, we can determine the relative quality, the adequacy of this quality with respect to pragmatic considerations, and identify good and bad trends during development. While no two software engineers will ever agree on an optimum definition of software quality, they will agree that the most important perspective of software quality is its ease of change. We can call this flexibility, adaptability, or some other vague term, but the critical characteristic of software is that it is soft. The easier the product is to modify, the easier it is to achieve any other software quality perspective. This paper presents objective quality metrics derived from consistent lifecycle perspectives of rework which, when used in concert with an evolutionary development approach, can provide useful insight to produce better quality per unit cost/schedule or to achieve adequate quality more efficiently. The usefulness of these metrics is evaluated by applying them to a large, real world, Ada project.
Building quality into medical product software design.
Mallory, S R
1993-01-01
The software engineering and quality assurance disciplines are a requisite to the design of safe and effective software-based medical devices. It is in the areas of software methodology and process that the most beneficial application of these disciplines to software development can be made. Software is a product of complex operations and methodologies and is not amenable to the traditional electromechanical quality assurance processes. Software quality must be built in by the developers, with the software verification and validation engineers acting as the independent instruments for ensuring compliance with performance objectives and with development and maintenance standards. The implementation of a software quality assurance program is a complex process involving management support, organizational changes, and new skill sets, but the benefits are profound. Its rewards provide safe, reliable, cost-effective, maintainable, and manageable software, which may significantly speed the regulatory review process and therefore potentially shorten the overall time to market. The use of a trial project can greatly facilitate the learning process associated with the first-time application of a software quality assurance program.
A measurement system for large, complex software programs
NASA Technical Reports Server (NTRS)
Rone, Kyle Y.; Olson, Kitty M.; Davis, Nathan E.
1994-01-01
This paper describes measurement systems required to forecast, measure, and control activities for large, complex software development and support programs. Initial software cost and quality analysis provides the foundation for meaningful management decisions as a project evolves. In modeling the cost and quality of software systems, the relationship between the functionality, quality, cost, and schedule of the product must be considered. This explicit relationship is dictated by the criticality of the software being developed. This balance between cost and quality is a viable software engineering trade-off throughout the life cycle. Therefore, the ability to accurately estimate the cost and quality of software systems is essential to providing reliable software on time and within budget. Software cost models relate the product error rate to the percent of the project labor that is required for independent verification and validation. The criticality of the software determines which cost model is used to estimate the labor required to develop the software. Software quality models yield an expected error discovery rate based on the software size, criticality, software development environment, and the level of competence of the project and developers with respect to the processes being employed.
Preliminary description of the area navigation software for a microcomputer-based Loran-C receiver
NASA Technical Reports Server (NTRS)
Oguri, F.
1983-01-01
The development of new software implementation of this software on a microcomputer (MOS 6502) to provide high quality navigation information is described. This software development provides Area/Route Navigation (RNAV) information from Time Differences (TDs) in raw form using an elliptical Earth model and a spherical model. The software is prepared for the microcomputer based Loran-C receiver. To compute navigation infomation, a (MOS 6502) microcomputer and a mathematical chip (AM 9511A) were combined with the Loran-C receiver. Final data reveals that this software does indeed provide accurate information with reasonable execution times.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, C.
1997-11-01
For many years, software quality assurance lagged behind hardware quality assurance in terms of methods, metrics, and successful results. New approaches such as Quality Function Deployment (QFD) the ISO 9000-9004 standards, the SEI maturity levels, and Total Quality Management (TQM) are starting to attract wide attention, and in some cases to bring software quality levels up to a parity with manufacturing quality levels. Since software is on the critical path for many engineered products, and for internal business systems as well, the new approaches are starting to affect global competition and attract widespread international interest. It can be hypothesized thatmore » success in mastering software quality will be a key strategy for dominating global software markets in the 21st century.« less
Requirements UML Tool (RUT) Expanded for Extreme Programming (CI02)
NASA Technical Reports Server (NTRS)
McCoy, James R.
2003-01-01
A procedure for capturing and managing system requirements that incorporates XP user stories. Because costs associated with identifying problems in requirements increase dramatically over the lifecycle of a project, a method for identifying sources of software risks in user stories is urgently needed. This initiative aims to determine a set of guide-lines for user stories that will result in high-quality requirement. To further this initiative, a tool is needed to analyze user stories that can assess the quality of individual user stories, detect sources cf software risk's, produce software metrics, and identify areas in user stories that can be improved.
CoLiTec software - detection of the near-zero apparent motion
NASA Astrophysics Data System (ADS)
Khlamov, Sergii V.; Savanevych, Vadym E.; Briukhovetskyi, Olexandr B.; Pohorelov, Artem V.
2017-06-01
In this article we described CoLiTec software for full automated frames processing. CoLiTec software allows processing the Big Data of observation results as well as processing of data that is continuously formed during observation. The scope of solving tasks includes frames brightness equalization, moving objects detection, astrometry, photometry, etc. Along with the high efficiency of Big Data processing CoLiTec software also ensures high accuracy of data measurements. A comparative analysis of the functional characteristics and positional accuracy was performed between CoLiTec and Astrometrica software. The benefits of CoLiTec used with wide field and low quality frames were observed. The efficiency of the CoLiTec software was proved by about 700.000 observations and over 1.500 preliminary discoveries.
Software component quality evaluation
NASA Technical Reports Server (NTRS)
Clough, A. J.
1991-01-01
The paper describes a software inspection process that can be used to evaluate the quality of software components. Quality criteria, process application, independent testing of the process and proposed associated tool support are covered. Early results indicate that this technique is well suited for assessing software component quality in a standardized fashion. With automated machine assistance to facilitate both the evaluation and selection of software components, such a technique should promote effective reuse of software components.
Quality measures and assurance for AI (Artificial Intelligence) software
NASA Technical Reports Server (NTRS)
Rushby, John
1988-01-01
This report is concerned with the application of software quality and evaluation measures to AI software and, more broadly, with the question of quality assurance for AI software. Considered are not only the metrics that attempt to measure some aspect of software quality, but also the methodologies and techniques (such as systematic testing) that attempt to improve some dimension of quality, without necessarily quantifying the extent of the improvement. The report is divided into three parts Part 1 reviews existing software quality measures, i.e., those that have been developed for, and applied to, conventional software. Part 2 considers the characteristics of AI software, the applicability and potential utility of measures and techniques identified in the first part, and reviews those few methods developed specifically for AI software. Part 3 presents an assessment and recommendations for the further exploration of this important area.
An experience of qualified preventive screening: shiraz smart screening software.
Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza
2015-01-01
Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.
Villamor Ordozgoiti, Alberto; Delgado Hito, Pilar; Guix Comellas, Eva María; Fernandez Sanchez, Carlos Manuel; Garcia Hernandez, Milagros; Lluch Canut, Teresa
2016-01-01
Information and Communications Technologies in healthcare has increased the need to consider quality criteria through standardised processes. The aim of this study was to analyse the software quality evaluation models applicable to healthcare from the perspective of ICT-purchasers. Through a systematic literature review with the keywords software, product, quality, evaluation and health, we selected and analysed 20 original research papers published from 2005-2016 in health science and technology databases. The results showed four main topics: non-ISO models, software quality evaluation models based on ISO/IEC standards, studies analysing software quality evaluation models, and studies analysing ISO standards for software quality evaluation. The models provide cost-efficiency criteria for specific software, and improve use outcomes. The ISO/IEC25000 standard is shown as the most suitable for evaluating the quality of ICTs for healthcare use from the perspective of institutional acquisition.
Sweidan, Michelle; Williamson, Margaret; Reeve, James F; Harvey, Ken; O'Neill, Jennifer A; Schattner, Peter; Snowdon, Teri
2010-04-15
Electronic prescribing is increasingly being used in primary care and in hospitals. Studies on the effects of e-prescribing systems have found evidence for both benefit and harm. The aim of this study was to identify features of e-prescribing software systems that support patient safety and quality of care and that are useful to the clinician and the patient, with a focus on improving the quality use of medicines. Software features were identified by a literature review, key informants and an expert group. A modified Delphi process was used with a 12-member multidisciplinary expert group to reach consensus on the expected impact of the features in four domains: patient safety, quality of care, usefulness to the clinician and usefulness to the patient. The setting was electronic prescribing in general practice in Australia. A list of 114 software features was developed. Most of the features relate to the recording and use of patient data, the medication selection process, prescribing decision support, monitoring drug therapy and clinical reports. The expert group rated 78 of the features (68%) as likely to have a high positive impact in at least one domain, 36 features (32%) as medium impact, and none as low or negative impact. Twenty seven features were rated as high positive impact across 3 or 4 domains including patient safety and quality of care. Ten features were considered "aspirational" because of a lack of agreed standards and/or suitable knowledge bases. This study defines features of e-prescribing software systems that are expected to support safety and quality, especially in relation to prescribing and use of medicines in general practice. The features could be used to develop software standards, and could be adapted if necessary for use in other settings and countries.
2010-01-01
Background Electronic prescribing is increasingly being used in primary care and in hospitals. Studies on the effects of e-prescribing systems have found evidence for both benefit and harm. The aim of this study was to identify features of e-prescribing software systems that support patient safety and quality of care and that are useful to the clinician and the patient, with a focus on improving the quality use of medicines. Methods Software features were identified by a literature review, key informants and an expert group. A modified Delphi process was used with a 12-member multidisciplinary expert group to reach consensus on the expected impact of the features in four domains: patient safety, quality of care, usefulness to the clinician and usefulness to the patient. The setting was electronic prescribing in general practice in Australia. Results A list of 114 software features was developed. Most of the features relate to the recording and use of patient data, the medication selection process, prescribing decision support, monitoring drug therapy and clinical reports. The expert group rated 78 of the features (68%) as likely to have a high positive impact in at least one domain, 36 features (32%) as medium impact, and none as low or negative impact. Twenty seven features were rated as high positive impact across 3 or 4 domains including patient safety and quality of care. Ten features were considered "aspirational" because of a lack of agreed standards and/or suitable knowledge bases. Conclusions This study defines features of e-prescribing software systems that are expected to support safety and quality, especially in relation to prescribing and use of medicines in general practice. The features could be used to develop software standards, and could be adapted if necessary for use in other settings and countries. PMID:20398294
Software quality for 1997 - what works and what doesn`t?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, C.
1997-11-01
This presentation provides a view of software quality for 1997 - what works and what doesn`t. For many years, software quality assurance lagged behind hardware quality assurance in terms of methods, metrics, and successful results. New approaches such as Quality Function Development (WFD) the ISO 9000-9004 standards, the SEI maturity levels, and Total Quality Management (TQM) are starting to attract wide attention, and in some cases to bring software quality levels up to a parity with manufacturing quality levels.
Software metrics: Software quality metrics for distributed systems. [reliability engineering
NASA Technical Reports Server (NTRS)
Post, J. V.
1981-01-01
Software quality metrics was extended to cover distributed computer systems. Emphasis is placed on studying embedded computer systems and on viewing them within a system life cycle. The hierarchy of quality factors, criteria, and metrics was maintained. New software quality factors were added, including survivability, expandability, and evolvability.
ERIC Educational Resources Information Center
Radulescu, Iulian Ionut
2006-01-01
Software complexity is the most important software quality attribute and a very useful instrument in the study of software quality. Is one of the factors that affect most of the software quality characteristics, including maintainability. It is very important to quantity this influence and identify the means to keep it under control; by using…
McDonald, James E; Kessler, Marcus M; Hightower, Jeremy L; Henry, Susan D; Deloney, Linda A
2013-12-01
With increasing volumes of complex imaging cases and rising economic pressure on physician staffing, timely reporting will become progressively challenging. Current and planned iterations of PACS and electronic medical record systems do not offer workflow management tools to coordinate delivery of imaging interpretations with the needs of the patient and ordering physician. The adoption of a server-based enterprise collaboration software system by our Division of Nuclear Medicine has significantly improved our efficiency and quality of service.
ERIC Educational Resources Information Center
Rudner, Lawrence M.; Glass Gene V.; Evartt, David L.; Emery, Patrick J.
This manual and the accompanying software are intended to provide a step-by-step guide to conducting a meta-analytic study along with references for further reading and free high-quality software, "Meta-Stat.""Meta-Stat" is a comprehensive package designed to help in the meta-analysis of research studies in the social and behavioral sciences.…
Abstract for 1999 Rational Software User Conference
NASA Technical Reports Server (NTRS)
Dunphy, Julia; Rouquette, Nicolas; Feather, Martin; Tung, Yu-Wen
1999-01-01
We develop spacecraft fault-protection software at NASA/JPL. Challenges exemplified by our task: 1) high-quality systems - need for extensive validation & verification; 2) multi-disciplinary context - involves experts from diverse areas; 3) embedded systems - must adapt to external practices, notations, etc.; and 4) development pressures - NASA's mandate of "better, faster, cheaper".
Radioactive Decay: Audio Data Collection
ERIC Educational Resources Information Center
Struthers, Allan
2009-01-01
Many phenomena generate interesting audible time series. This data can be collected and processed using audio software. The free software package "Audacity" is used to demonstrate the process by recording, processing, and extracting click times from an inexpensive radiation detector. The high quality of the data is demonstrated with a simple…
NASA Technical Reports Server (NTRS)
Craig, Larry G.
2010-01-01
This slide presentation reviews three failures of software and how the failures contributed to or caused the failure of a launch or payload insertion into orbit. In order to avoid these systematic failures in the future, failure mitigation strategies are suggested for use.
Teaching Quality Object-Oriented Programming
ERIC Educational Resources Information Center
Feldman, Yishai A.
2005-01-01
Computer science students need to learn how to write high-quality software. An important methodology for achieving quality is design-by-contract, in which code is developed together with its specification, which is given as class invariants and method pre- and postconditions. This paper describes practical experience in teaching design-by-contract…
Evaluation of features to support safety and quality in general practice clinical software
2011-01-01
Background Electronic prescribing is now the norm in many countries. We wished to find out if clinical software systems used by general practitioners in Australia include features (functional capabilities and other characteristics) that facilitate improved patient safety and care, with a focus on quality use of medicines. Methods Seven clinical software systems used in general practice were evaluated. Fifty software features that were previously rated as likely to have a high impact on safety and/or quality of care in general practice were tested and are reported here. Results The range of results for the implementation of 50 features across the 7 clinical software systems was as follows: 17-31 features (34-62%) were fully implemented, 9-13 (18-26%) partially implemented, and 9-20 (18-40%) not implemented. Key findings included: Access to evidence based drug and therapeutic information was limited. Decision support for prescribing was available but varied markedly between systems. During prescribing there was potential for medicine mis-selection in some systems, and linking a medicine with its indication was optional. The definition of 'current medicines' versus 'past medicines' was not always clear. There were limited resources for patients, and some medicines lists for patients were suboptimal. Results were provided to the software vendors, who were keen to improve their systems. Conclusions The clinical systems tested lack some of the features expected to support patient safety and quality of care. Standards and certification for clinical software would ensure that safety features are present and that there is a minimum level of clinical functionality that clinicians could expect to find in any system.
Four simple recommendations to encourage best practices in research software
Jiménez, Rafael C.; Kuzak, Mateusz; Alhamdoosh, Monther; Barker, Michelle; Batut, Bérénice; Borg, Mikael; Capella-Gutierrez, Salvador; Chue Hong, Neil; Cook, Martin; Corpas, Manuel; Flannery, Madison; Garcia, Leyla; Gelpí, Josep Ll.; Gladman, Simon; Goble, Carole; González Ferreiro, Montserrat; Gonzalez-Beltran, Alejandra; Griffin, Philippa C.; Grüning, Björn; Hagberg, Jonas; Holub, Petr; Hooft, Rob; Ison, Jon; Katz, Daniel S.; Leskošek, Brane; López Gómez, Federico; Oliveira, Luis J.; Mellor, David; Mosbergen, Rowland; Mulder, Nicola; Perez-Riverol, Yasset; Pergl, Robert; Pichler, Horst; Pope, Bernard; Sanz, Ferran; Schneider, Maria V.; Stodden, Victoria; Suchecki, Radosław; Svobodová Vařeková, Radka; Talvik, Harry-Anton; Todorov, Ilian; Treloar, Andrew; Tyagi, Sonika; van Gompel, Maarten; Vaughan, Daniel; Via, Allegra; Wang, Xiaochuan; Watson-Haigh, Nathan S.; Crouch, Steve
2017-01-01
Scientific research relies on computer software, yet software is not always developed following practices that ensure its quality and sustainability. This manuscript does not aim to propose new software development best practices, but rather to provide simple recommendations that encourage the adoption of existing best practices. Software development best practices promote better quality software, and better quality software improves the reproducibility and reusability of research. These recommendations are designed around Open Source values, and provide practical suggestions that contribute to making research software and its source code more discoverable, reusable and transparent. This manuscript is aimed at developers, but also at organisations, projects, journals and funders that can increase the quality and sustainability of research software by encouraging the adoption of these recommendations. PMID:28751965
Four simple recommendations to encourage best practices in research software.
Jiménez, Rafael C; Kuzak, Mateusz; Alhamdoosh, Monther; Barker, Michelle; Batut, Bérénice; Borg, Mikael; Capella-Gutierrez, Salvador; Chue Hong, Neil; Cook, Martin; Corpas, Manuel; Flannery, Madison; Garcia, Leyla; Gelpí, Josep Ll; Gladman, Simon; Goble, Carole; González Ferreiro, Montserrat; Gonzalez-Beltran, Alejandra; Griffin, Philippa C; Grüning, Björn; Hagberg, Jonas; Holub, Petr; Hooft, Rob; Ison, Jon; Katz, Daniel S; Leskošek, Brane; López Gómez, Federico; Oliveira, Luis J; Mellor, David; Mosbergen, Rowland; Mulder, Nicola; Perez-Riverol, Yasset; Pergl, Robert; Pichler, Horst; Pope, Bernard; Sanz, Ferran; Schneider, Maria V; Stodden, Victoria; Suchecki, Radosław; Svobodová Vařeková, Radka; Talvik, Harry-Anton; Todorov, Ilian; Treloar, Andrew; Tyagi, Sonika; van Gompel, Maarten; Vaughan, Daniel; Via, Allegra; Wang, Xiaochuan; Watson-Haigh, Nathan S; Crouch, Steve
2017-01-01
Scientific research relies on computer software, yet software is not always developed following practices that ensure its quality and sustainability. This manuscript does not aim to propose new software development best practices, but rather to provide simple recommendations that encourage the adoption of existing best practices. Software development best practices promote better quality software, and better quality software improves the reproducibility and reusability of research. These recommendations are designed around Open Source values, and provide practical suggestions that contribute to making research software and its source code more discoverable, reusable and transparent. This manuscript is aimed at developers, but also at organisations, projects, journals and funders that can increase the quality and sustainability of research software by encouraging the adoption of these recommendations.
Free and open source software for the manipulation of digital images.
Solomon, Robert W
2009-06-01
Free and open source software is a type of software that is nearly as powerful as commercial software but is freely downloadable. This software can do almost everything that the expensive programs can. GIMP (gnu image manipulation program) is the free program that is comparable to Photoshop, and versions are available for Windows, Macintosh, and Linux platforms. This article briefly describes how GIMP can be installed and used to manipulate radiology images. It is no longer necessary to budget large amounts of money for high-quality software to achieve the goals of image processing and document creation because free and open source software is available for the user to download at will.
CrossTalk: The Journal of Defense Software Engineering. Volume 24, Number 6. November/December 2011
2011-11-01
Software Development.” Software Quality Professional Journal, American Society for Quality (ASQ), (March 2010) 4-14. 3. Nair, Gopalakrishnan T.R...Inspection Performance Metric”. Software Quality Professional Journal, American Society for Quality (ASQ), Volume 13, Issue 2, (March 2011) 14-26...the discovery process and are marketed by compa- nies such as Black Duck Software, OpenLogic, Palamida, and Protecode, among others.7 A number of open
Trivedi, Prinal; Edwards, Jode W; Wang, Jelai; Gadbury, Gary L; Srinivasasainagendra, Vinodh; Zakharkin, Stanislav O; Kim, Kyoungmi; Mehta, Tapan; Brand, Jacob P L; Patki, Amit; Page, Grier P; Allison, David B
2005-04-06
Many efforts in microarray data analysis are focused on providing tools and methods for the qualitative analysis of microarray data. HDBStat! (High-Dimensional Biology-Statistics) is a software package designed for analysis of high dimensional biology data such as microarray data. It was initially developed for the analysis of microarray gene expression data, but it can also be used for some applications in proteomics and other aspects of genomics. HDBStat! provides statisticians and biologists a flexible and easy-to-use interface to analyze complex microarray data using a variety of methods for data preprocessing, quality control analysis and hypothesis testing. Results generated from data preprocessing methods, quality control analysis and hypothesis testing methods are output in the form of Excel CSV tables, graphs and an Html report summarizing data analysis. HDBStat! is a platform-independent software that is freely available to academic institutions and non-profit organizations. It can be downloaded from our website http://www.soph.uab.edu/ssg_content.asp?id=1164.
Operational excellence (six sigma) philosophy: Application to software quality assurance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lackner, M.
1997-11-01
This report contains viewgraphs on operational excellence philosophy of six sigma applied to software quality assurance. This report outlines the following: goal of six sigma; six sigma tools; manufacturing vs administrative processes; Software quality assurance document inspections; map software quality assurance requirements document; failure mode effects analysis for requirements document; measuring the right response variables; and questions.
SUGAR: graphical user interface-based data refiner for high-throughput DNA sequencing.
Sato, Yukuto; Kojima, Kaname; Nariai, Naoki; Yamaguchi-Kabata, Yumi; Kawai, Yosuke; Takahashi, Mamoru; Mimori, Takahiro; Nagasaki, Masao
2014-08-08
Next-generation sequencers (NGSs) have become one of the main tools for current biology. To obtain useful insights from the NGS data, it is essential to control low-quality portions of the data affected by technical errors such as air bubbles in sequencing fluidics. We develop a software SUGAR (subtile-based GUI-assisted refiner) which can handle ultra-high-throughput data with user-friendly graphical user interface (GUI) and interactive analysis capability. The SUGAR generates high-resolution quality heatmaps of the flowcell, enabling users to find possible signals of technical errors during the sequencing. The sequencing data generated from the error-affected regions of a flowcell can be selectively removed by automated analysis or GUI-assisted operations implemented in the SUGAR. The automated data-cleaning function based on sequence read quality (Phred) scores was applied to a public whole human genome sequencing data and we proved the overall mapping quality was improved. The detailed data evaluation and cleaning enabled by SUGAR would reduce technical problems in sequence read mapping, improving subsequent variant analysis that require high-quality sequence data and mapping results. Therefore, the software will be especially useful to control the quality of variant calls to the low population cells, e.g., cancers, in a sample with technical errors of sequencing procedures.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
...] Extension of the Period for Comments on the Enhancement of Quality of Software-Related Patents AGENCY... announcing the formation of a partnership with the software community to enhance the quality of software-related patents (Software Partnership), and a request for comments on the preparation of patent...
A Petri Net-Based Software Process Model for Developing Process-Oriented Information Systems
NASA Astrophysics Data System (ADS)
Li, Yu; Oberweis, Andreas
Aiming at increasing flexibility, efficiency, effectiveness, and transparency of information processing and resource deployment in organizations to ensure customer satisfaction and high quality of products and services, process-oriented information systems (POIS) represent a promising realization form of computerized business information systems. Due to the complexity of POIS, explicit and specialized software process models are required to guide POIS development. In this chapter we characterize POIS with an architecture framework and present a Petri net-based software process model tailored for POIS development with consideration of organizational roles. As integrated parts of the software process model, we also introduce XML nets, a variant of high-level Petri nets as basic methodology for business processes modeling, and an XML net-based software toolset providing comprehensive functionalities for POIS development.
Tactical Approaches for Making a Successful Satellite Passive Microwave ESDR
NASA Astrophysics Data System (ADS)
Hardman, M.; Brodzik, M. J.; Gotberg, J.; Long, D. G.; Paget, A. C.
2014-12-01
Our NASA MEaSUREs project is producing a new, enhanced resolution gridded Earth System Data Record for the entire satellite passive microwave (SMMR, SSM/I-SSMIS and AMSR-E) time series. Our project goals are twofold: to produce a well-documented, consistently processed, high-quality historical record at higher spatial resolutions than have previously been available, and to transition the production software to the NSIDC DAAC for ongoing processing after our project completion. In support of these goals, our distributed team at BYU and NSIDC faces project coordination challenges to produce a high-quality data set that our user community will accept as a replacement for the currently available historical versions of these data. We work closely with our DAAC liaison on format specifications, data and metadata plans, and project progress. In order for the user community to understand and support our project, we have solicited a team of Early Adopters who are reviewing and evaluating a prototype version of the data. Early Adopter feedback will be critical input to our final data content and format decisions. For algorithm transparency and accountability, we have released an Algorithm Theoretical Basis Document (ATBD) and detailed supporting technical documentation, with rationale for all algorithm implementation decisions. For distributed team management, we are using collaborative tools for software revision control and issue tracking. For reliably transitioning a research-quality image reconstruction software system to production-quality software suitable for use at the DAAC, we have adopted continuous integration methods for running automated regression testing. Our presentation will summarize bothadvantages and challenges of each of these tactics in ensuring production of a successful ESDR and an enduring production software system.
Wawrzyniak, Zbigniew M; Paczesny, Daniel; Mańczuk, Marta; Zatoński, Witold A
2011-01-01
Large-scale epidemiologic studies can assess health indicators differentiating social groups and important health outcomes of the incidence and mortality of cancer, cardiovascular disease, and others, to establish a solid knowledgebase for the prevention management of premature morbidity and mortality causes. This study presents new advanced methods of data collection and data management systems with current data quality control and security to ensure high quality data assessment of health indicators in the large epidemiologic PONS study (The Polish-Norwegian Study). The material for experiment is the data management design of the large-scale population study in Poland (PONS) and the managed processes are applied into establishing a high quality and solid knowledge. The functional requirements of the PONS study data collection, supported by the advanced IT web-based methods, resulted in medical data of a high quality, data security, with quality data assessment, control process and evolution monitoring are fulfilled and shared by the IT system. Data from disparate and deployed sources of information are integrated into databases via software interfaces, and archived by a multi task secure server. The practical and implemented solution of modern advanced database technologies and remote software/hardware structure successfully supports the research of the big PONS study project. Development and implementation of follow-up control of the consistency and quality of data analysis and the processes of the PONS sub-databases have excellent measurement properties of data consistency of more than 99%. The project itself, by tailored hardware/software application, shows the positive impact of Quality Assurance (QA) on the quality of outcomes analysis results, effective data management within a shorter time. This efficiency ensures the quality of the epidemiological data and indicators of health by the elimination of common errors of research questionnaires and medical measurements.
FSO and quality of service software prediction
NASA Astrophysics Data System (ADS)
Bouchet, O.; Marquis, T.; Chabane, M.; Alnaboulsi, M.; Sizun, H.
2005-08-01
Free-space optical (FSO) communication links constitute an alternative option to radio relay links and to optical cables facing growth needs in high-speed telecommunications (abundance of unregulated bandwidth, rapid installation, availability of low-cost optical components offering a high data rate, etc). Their operationalisation requires a good knowledge of the atmospheric effects which can negatively affect role propagation and the availability of the link, and thus to the quality of service (QoS). Better control of these phenomena will allow for the evaluation of system performance and thus assist with improving reliability. The aim of this paper is to compare the behavior of a FSO link located in south of France (Toulouse: with the following parameters: around 270 meters (0.2 mile) long, 34 Mbps data rate, 850 nm wavelength and PDH frame) with airport meteorological data. The second aim of the paper is to assess in-house FSO quality of service prediction software, through comparing simulations with the optical link data and the weather data. The analysis uses in-house software FSO quality of service prediction software ("FSO Prediction") developed by France Telecom Research & Development, which integrates news fog fading equations (compare to Kim & al.) and includes multiple effects (geometrical attenuation, atmospheric fading, rain, snow, scintillation and refraction attenuation due to atmospheric turbulence, optical mispointing attenuation). The FSO link field trial, intended to enable the demonstration and evaluation of these different effects, is described; and preliminary results of the field trial, from December 2004 to May 2005, are then presented.
As EPA’s environmental research expands into new areas that involve the development of software, quality assurance concepts and procedures that were originally developed for environmental data collection may not be appropriate. Fortunately, software quality assurance is a ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willenbring, James M.; Bartlett, Roscoe Ainsworth; Heroux, Michael Allen
2012-01-01
Software lifecycles are becoming an increasingly important issue for computational science and engineering (CSE) software. The process by which a piece of CSE software begins life as a set of research requirements and then matures into a trusted high-quality capability is both commonplace and extremely challenging. Although an implicit lifecycle is obviously being used in any effort, the challenges of this process - respecting the competing needs of research vs. production - cannot be overstated. Here we describe a proposal for a well-defined software lifecycle process based on modern Lean/Agile software engineering principles. What we propose is appropriate for manymore » CSE software projects that are initially heavily focused on research but also are expected to eventually produce usable high-quality capabilities. The model is related to TriBITS, a build, integration and testing system, which serves as a strong foundation for this lifecycle model, and aspects of this lifecycle model are ingrained in the TriBITS system. Here, we advocate three to four phases or maturity levels that address the appropriate handling of many issues associated with the transition from research to production software. The goals of this lifecycle model are to better communicate maturity levels with customers and to help to identify and promote Software Engineering (SE) practices that will help to improve productivity and produce better software. An important collection of software in this domain is Trilinos, which is used as the motivation and the initial target for this lifecycle model. However, many other related and similar CSE (and non-CSE) software projects can also make good use of this lifecycle model, especially those that use the TriBITS system. Indeed this lifecycle process, if followed, will enable large-scale sustainable integration of many complex CSE software efforts across several institutions.« less
Quality Attributes for Mission Flight Software: A Reference for Architects
NASA Technical Reports Server (NTRS)
Wilmot, Jonathan; Fesq, Lorraine; Dvorak, Dan
2016-01-01
In the international standards for architecture descriptions in systems and software engineering (ISO/IEC/IEEE 42010), "concern" is a primary concept that often manifests itself in relation to the quality attributes or "ilities" that a system is expected to exhibit - qualities such as reliability, security and modifiability. One of the main uses of an architecture description is to serve as a basis for analyzing how well the architecture achieves its quality attributes, and that requires architects to be as precise as possible about what they mean in claiming, for example, that an architecture supports "modifiability." This paper describes a table, generated by NASA's Software Architecture Review Board, which lists fourteen key quality attributes, identifies different important aspects of each quality attribute and considers each aspect in terms of requirements, rationale, evidence, and tactics to achieve the aspect. This quality attribute table is intended to serve as a guide to software architects, software developers, and software architecture reviewers in the domain of mission-critical real-time embedded systems, such as space mission flight software.
A research review of quality assessment for software
NASA Technical Reports Server (NTRS)
1991-01-01
Measures were recommended to assess the quality of software submitted to the AdaNet program. The quality factors that are important to software reuse are explored and methods of evaluating those factors are discussed. Quality factors important to software reuse are: correctness, reliability, verifiability, understandability, modifiability, and certifiability. Certifiability is included because the documentation of many factors about a software component such as its efficiency, portability, and development history, constitute a class for factors important to some users, not important at all to other, and impossible for AdaNet to distinguish between a priori. The quality factors may be assessed in different ways. There are a few quantitative measures which have been shown to indicate software quality. However, it is believed that there exists many factors that indicate quality and have not been empirically validated due to their subjective nature. These subjective factors are characterized by the way in which they support the software engineering principles of abstraction, information hiding, modularity, localization, confirmability, uniformity, and completeness.
A Structure for Creating Quality Software.
ERIC Educational Resources Information Center
Christensen, Larry C.; Bodey, Michael R.
1990-01-01
Addresses the issue of assuring quality software for use in computer-aided instruction and presents a structure by which developers can create quality courseware. Differences between courseware and computer-aided instruction software are discussed, methods for testing software are described, and human factors issues as well as instructional design…
[Establishment of a 3D finite element model of human skull using MSCT images and mimics software].
Huang, Ping; Li, Zheng-dong; Shao, Yu; Zou, Dong-hua; Liu, Ning-guo; Li, Li; Chen, Yuan-yuan; Wan, Lei; Chen, Yi-jiu
2011-02-01
To establish a human 3D finite element skull model, and to explore its value in biomechanics analysis. The cadaveric head was scanned and then 3D skull model was created using Mimics software based on 2D CT axial images. The 3D skull model was optimized by preprocessor along with creation of the surface and volume meshes. The stress changes, after the head was struck by an object or the head hit the ground directly, were analyzed using ANSYS software. The original 3D skull model showed a large number of triangles with a poor quality and high similarity with the real head, while the optimized model showed high quality surface and volume meshes with a small number of triangles comparatively. The model could show the local and global stress changes effectively. The human 3D skull model can be established using MSCT and Mimics software and provides a good finite element model for biomechanics analysis. This model may also provide a base for the study of head stress changes following different forces.
Feasibility Study on Fully Automatic High Quality Translation: Volume I. Final Technical Report.
ERIC Educational Resources Information Center
Lehmann, Winifred P.; Stachowitz, Rolf
The object of this theoretical inquiry is to examine the controversial issue of a fully automatic high quality translation (FAHQT) in the light of past and projected advances in linguistic theory and hardware/software capability. This first volume of a two-volume report discusses the requirements of translation and aspects of human and machine…
Nabizadeh, Ramin; Valadi Amin, Maryam; Alimohammadi, Mahmood; Naddafi, Kazem; Mahvi, Amir Hossein; Yousefzadeh, Samira
2013-04-26
Developing a water quality index which is used to convert the water quality dataset into a single number is the most important task of most water quality monitoring programmes. As the water quality index setup is based on different local obstacles, it is not feasible to introduce a definite water quality index to reveal the water quality level. In this study, an innovative software application, the Iranian Water Quality Index Software (IWQIS), is presented in order to facilitate calculation of a water quality index based on dynamic weight factors, which will help users to compute the water quality index in cases where some parameters are missing from the datasets. A dataset containing 735 water samples of drinking water quality in different parts of the country was used to show the performance of this software using different criteria parameters. The software proved to be an efficient tool to facilitate the setup of water quality indices based on flexible use of variables and water quality databases.
NASA Technical Reports Server (NTRS)
Buckner, J. D.; Council, H. W.; Edwards, T. R.
1974-01-01
Description of the hardware and software implementing the system of time-lapse reproduction of images through interactive graphics (TRIIG). The system produces a quality hard copy of processed images in a fast and inexpensive manner. This capability allows for optimal development of processing software through the rapid viewing of many image frames in an interactive mode. Three critical optical devices are used to reproduce an image: an Optronics photo reader/writer, the Adage Graphics Terminal, and Polaroid Type 57 high speed film. Typical sources of digitized images are observation satellites, such as ERTS or Mariner, computer coupled electron microscopes for high-magnification studies, or computer coupled X-ray devices for medical research.
Effect of Software Version on the Accuracy of an Intraoral Scanning Device.
Haddadi, Yasser; Bahrami, Golnosh; Isidor, Flemming
2018-04-06
To investigate the impact of software version on the accuracy of an intraoral scanning device. A master tooth was scanned with a high-precision optical scanner and then 10 times with a CEREC Omnicam scanner with software versions 4.4.0 and 4.4.4. Discrepancies were measured using quality control software. Mean deviation for 4.4.0 was 36.2 ± 35 μm and for 4.4.4 was 20.7 ± 14.2 μm (P ≤ .001). Software version has a significant impact on the accuracy of an intraoral scanner. It is important that researchers also publish the software version of scanners when publishing their findings.
NASA Astrophysics Data System (ADS)
Bolch, T.; Mölg, N.
2017-12-01
The application of Structure-from-Motion (SfM) to generate digital terrain models (DTMs) derived out of images from various kinds of sources has strongly increased in recent years. The major reason for this is its easy-to-use handling in comparison to conventional photogrammetry. In glaciology, DTMs are intensely used, among others, to calculate the geodetic mass balances. Few studies investigated the application of SfM to aerial images in mountainous terrain and results look promising. We tested this technique in a demanding environment in the Swiss Alps including very steep slopes, snow and ice covered terrain. SfM (using the commercial software packages of Agisoft Photoscan and Pix4DMapper) and conventional photogrammetry (ERDAS Photogrammetry) were applied on archival aerial images for nine dates between 1946 and 2005 the results were compared regarding bundle adjustment and final DTM quality. The overall precision of the DTMs could be defined with the use of a modern, high-quality reference DTM by Swisstopo. Results suggest a high performance of SfM to produce DTMs of similar quality as conventional photogrammetry. A ground resolution of high quality (little noise and artefacts) can be up to 50% higher, with 3-6 times less user effort. However, the controls on the commercial SfM software packages are limited in comparison to ERDAS Photogrammetry. SfM performs less reliably when few images with little overlap are processed. Overall, the uncertainty of DTMs from the different software are comparable and mostly within the uncertainty range of the reference DTM, making them highly valuable for glaciological purposes. Even though SfM facilitates the largely automated production of high quality DTMs, the user is not exempt from a thorough quality check, at best with reference data where available.
Area navigation implementation for a microcomputer-based LORAN-C receiver
NASA Technical Reports Server (NTRS)
Oguri, F.
1983-01-01
Engineering performed to make LORAN-C a more useful and practical navigation system for general aviation is described. Development of new software, and implementation of this software on a (MOS6502) microcomputer to provide high quality practical area navigation information directly to the pilot and considered. Flight tests were performed specifically to examine the efficacy of this new software. Final results were exceptionally good and clearly demonstrate the merits of this new LORAN-C area navigation system.
NASA Technical Reports Server (NTRS)
2000-01-01
Video Pics is a software program that generates high-quality photos from video. The software was developed under an SBIR contract with Marshall Space Flight Center by Redhawk Vision, Inc.--a subsidiary of Irvine Sensors Corporation. Video Pics takes information content from multiple frames of video and enhances the resolution of a selected frame. The resulting image has enhanced sharpness and clarity like that of a 35 mm photo. The images are generated as digital files and are compatible with image editing software.
On the release of cppxfel for processing X-ray free-electron laser images.
Ginn, Helen Mary; Evans, Gwyndaf; Sauter, Nicholas K; Stuart, David Ian
2016-06-01
As serial femtosecond crystallography expands towards a variety of delivery methods, including chip-based methods, and smaller collected data sets, the requirement to optimize the data analysis to produce maximum structure quality is becoming increasingly pressing. Here cppxfel , a software package primarily written in C++, which showcases several data analysis techniques, is released. This software package presently indexes images using DIALS (diffraction integration for advanced light sources) and performs an initial orientation matrix refinement, followed by post-refinement of individual images against a reference data set. Cppxfel is released with the hope that the unique and useful elements of this package can be repurposed for existing software packages. However, as released, it produces high-quality crystal structures and is therefore likely to be also useful to experienced users of X-ray free-electron laser (XFEL) software who wish to maximize the information extracted from a limited number of XFEL images.
On the release of cppxfel for processing X-ray free-electron laser images
Ginn, Helen Mary; Evans, Gwyndaf; Sauter, Nicholas K.; ...
2016-05-11
As serial femtosecond crystallography expands towards a variety of delivery methods, including chip-based methods, and smaller collected data sets, the requirement to optimize the data analysis to produce maximum structure quality is becoming increasingly pressing. Herecppxfel, a software package primarily written in C++, which showcases several data analysis techniques, is released. This software package presently indexes images using DIALS (diffraction integration for advanced light sources) and performs an initial orientation matrix refinement, followed by post-refinement of individual images against a reference data set.Cppxfelis released with the hope that the unique and useful elements of this package can be repurposed formore » existing software packages. However, as released, it produces high-quality crystal structures and is therefore likely to be also useful to experienced users of X-ray free-electron laser (XFEL) software who wish to maximize the information extracted from a limited number of XFEL images.« less
Engineering Quality Software: 10 Recommendations for Improved Software Quality Management
2010-04-27
lack of user involvement • Inadequate Software Process Management & Control By Contractors • No “Team” of Vendors and users; little SME participation...1990 Quality Perspectives • Process Quality ( CMMI ) • Product Quality (ISO/IEC 2500x) – Internal Quality Attributes – External Quality Attributes... CMMI /ISO 9000 Assessments – Capture organizational knowledge • Identify best practices, lessons learned Know where you are, and where you need to be
Getting started on metrics - Jet Propulsion Laboratory productivity and quality
NASA Technical Reports Server (NTRS)
Bush, M. W.
1990-01-01
A review is presented to describe the effort and difficulties of reconstructing fifteen years of JPL software history. In 1987 the collection and analysis of project data were started with the objective of creating laboratory-wide measures of quality and productivity for software development. As a result of this two-year Software Product Assurance metrics study, a rough measurement foundation for software productivity and software quality, and an order-of-magnitude quantitative baseline for software systems and subsystems are now available.
Nolden, Marco; Zelzer, Sascha; Seitel, Alexander; Wald, Diana; Müller, Michael; Franz, Alfred M; Maleike, Daniel; Fangerau, Markus; Baumhauer, Matthias; Maier-Hein, Lena; Maier-Hein, Klaus H; Meinzer, Hans-Peter; Wolf, Ivo
2013-07-01
The Medical Imaging Interaction Toolkit (MITK) has been available as open-source software for almost 10 years now. In this period the requirements of software systems in the medical image processing domain have become increasingly complex. The aim of this paper is to show how MITK evolved into a software system that is able to cover all steps of a clinical workflow including data retrieval, image analysis, diagnosis, treatment planning, intervention support, and treatment control. MITK provides modularization and extensibility on different levels. In addition to the original toolkit, a module system, micro services for small, system-wide features, a service-oriented architecture based on the Open Services Gateway initiative (OSGi) standard, and an extensible and configurable application framework allow MITK to be used, extended and deployed as needed. A refined software process was implemented to deliver high-quality software, ease the fulfillment of regulatory requirements, and enable teamwork in mixed-competence teams. MITK has been applied by a worldwide community and integrated into a variety of solutions, either at the toolkit level or as an application framework with custom extensions. The MITK Workbench has been released as a highly extensible and customizable end-user application. Optional support for tool tracking, image-guided therapy, diffusion imaging as well as various external packages (e.g. CTK, DCMTK, OpenCV, SOFA, Python) is available. MITK has also been used in several FDA/CE-certified applications, which demonstrates the high-quality software and rigorous development process. MITK provides a versatile platform with a high degree of modularization and interoperability and is well suited to meet the challenging tasks of today's and tomorrow's clinically motivated research.
Paiva, Anthony; Shou, Wilson Z
2016-08-01
The last several years have seen the rapid adoption of the high-resolution MS (HRMS) for bioanalytical support of high throughput in vitro ADME profiling. Many capable software tools have been developed and refined to process quantitative HRMS bioanalysis data for ADME samples with excellent performance. Additionally, new software applications specifically designed for quan/qual soft spot identification workflows using HRMS have greatly enhanced the quality and efficiency of the structure elucidation process for high throughput metabolite ID in early in vitro ADME profiling. Finally, novel approaches in data acquisition and compression, as well as tools for transferring, archiving and retrieving HRMS data, are being continuously refined to tackle the issue of large data file size typical for HRMS analyses.
Quality control in urodynamics and the role of software support in the QC procedure.
Hogan, S; Jarvis, P; Gammie, A; Abrams, P
2011-11-01
This article aims to identify quality control (QC) best practice, to review published QC audits in order to identify how closely good practice is followed, and to carry out a market survey of the software features that support QC offered by urodynamics machines available in the UK. All UK distributors of urodynamic systems were contacted and asked to provide information on the software features relating to data quality of the products they supply. The results of the market survey show that the features offered by manufacturers differ greatly. Automated features, which can be turned off in most cases, include: cough recognition, detrusor contraction detection, and high pressure alerts. There are currently no systems that assess data quality based on published guidelines. A literature review of current QC guidelines for urodynamics was carried out; QC audits were included in the literature review to see how closely guidelines were being followed. This review highlights the fact that basic QC is not being carried out effectively by urodynamicists. Based on the software features currently available and the results of the literature review there is both the need and capacity for a greater degree of automation in relation to urodynamic data quality and accuracy assessment. Some progress has been made in this area and certain manufacturers have already developed automated cough detection. Copyright © 2011 Wiley Periodicals, Inc.
Proteomics Quality Control: Quality Control Software for MaxQuant Results.
Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan
2016-03-04
Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .
de Oliveira, Marcus Vinicius Linhares; Santos, António Carvalho; Paulo, Graciano; Campos, Paulo Sergio Flores; Santos, Joana
2017-06-01
The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.
Software Reviews Since Acquisition Reform - The Artifact Perspective
2004-01-01
Risk Management OLD NEW Slide 13Acquisition of Software Intensive Systems 2004 – Peter Hantos Single, basic software paradigm Single processor Low...software risk mitigation related trade-offs must be done together Integral Software Engineering Activities Process Maturity and Quality Frameworks Quality
A NASA family of minicomputer systems, Appendix A
NASA Technical Reports Server (NTRS)
Deregt, M. P.; Dulfer, J. E.
1972-01-01
This investigation was undertaken to establish sufficient specifications, or standards, for minicomputer hardware and software to provide NASA with realizable economics in quantity purchases, interchangeability of minicomputers, software, storage and peripherals, and a uniformly high quality. The standards will define minicomputer system component types, each specialized to its intended NASA application, in as many levels of capacity as required.
NASA Technical Reports Server (NTRS)
Basili, Victor R.
1992-01-01
The concepts of quality improvements have permeated many businesses. It is clear that the nineties will be the quality era for software and there is a growing need to develop or adapt quality improvement approaches to the software business. Thus we must understand software as an artifact and software as a business. Since the business we are dealing with is software, we must understand the nature of software and software development. The software discipline is evolutionary and experimental; it is a laboratory science. Software is development not production. The technologies of the discipline are human based. There is a lack of models that allow us to reason about the process and the product. All software is not the same; process is a variable, goals are variable, etc. Packaged, reusable, experiences require additional resources in the form of organization, processes, people, etc. There have been a variety of organizational frameworks proposed to improve quality for various businesses. The ones discussed in this presentation include: Plan-Do-Check-Act, a quality improvement process based upon a feedback cycle for optimizing a single process model/production line; the Experience Factory/Quality Improvement Paradigm, continuous improvements through the experimentation, packaging, and reuse of experiences based upon a business's needs; Total Quality Management, a management approach to long term success through customer satisfaction based on the participation of all members of an organization; the SEI capability maturity model, a staged process improvement based upon assessment with regard to a set of key process areas until you reach a level 5 which represents a continuous process improvement; and Lean (software) Development, a principle supporting the concentration of the production on 'value added' activities and the elimination of reduction of 'not value added' activities.
Establishing Qualitative Software Metrics in Department of the Navy Programs
2015-10-29
dedicated to provide the highest quality software to its users. In doing, there is a need for a formalized set of Software Quality Metrics . The goal...of this paper is to establish the validity of those necessary Quality metrics . In our approach we collected the data of over a dozen programs...provide the necessary variable data for our formulas and tested the formulas for validity. Keywords: metrics ; software; quality I. PURPOSE Space
2013-01-01
Background Developing a water quality index which is used to convert the water quality dataset into a single number is the most important task of most water quality monitoring programmes. As the water quality index setup is based on different local obstacles, it is not feasible to introduce a definite water quality index to reveal the water quality level. Findings In this study, an innovative software application, the Iranian Water Quality Index Software (IWQIS), is presented in order to facilitate calculation of a water quality index based on dynamic weight factors, which will help users to compute the water quality index in cases where some parameters are missing from the datasets. Conclusion A dataset containing 735 water samples of drinking water quality in different parts of the country was used to show the performance of this software using different criteria parameters. The software proved to be an efficient tool to facilitate the setup of water quality indices based on flexible use of variables and water quality databases. PMID:24499556
OPEN-SOURCE SOFTWARE IN DENTISTRY: A SYSTEMATIC REVIEW.
Chruściel-Nogalska, Małgorzata; Smektała, Tomasz; Tutak, Marcin; Sporniak-Tutak, Katarzyna; Olszewski, Raphael
2017-01-01
Technological development and the need for electronic health records management resulted in the need for a computer with dedicated, commercial software in daily dental practice. The alternative for commercial software may be open-source solutions. Therefore, this study reviewed the current literature on the availability and use of open-source software (OSS) in dentistry. A comprehensive database search was performed on February 1, 2017. Only articles published in peer-reviewed journals with a focus on the use or description of OSS were retrieved. The level of evidence, according to Oxford EBM Centre Levels of Evidence Scale was classified for all studies. Experimental studies underwent additional quality reporting assessment. The screening and evaluation process resulted in twenty-one studies from 1,940 articles found, with 10 of them being experimental studies. None of the articles provided level 1 evidence, and only one study was considered high quality following quality assessment. Twenty-six different OSS programs were described in the included studies of which ten were used for image visualization, five were used for healthcare records management, four were used for educations processes, one was used for remote consultation and simulation, and six were used for general purposes. Our analysis revealed that the dental literature on OSS consists of scarce, incomplete, and methodologically low quality information.
NASA Astrophysics Data System (ADS)
Comyn-Wattiau, Isabelle; Thalheim, Bernhard
Quality assurance is a growing research domain within the Information Systems (IS) and Conceptual Modeling (CM) disciplines. Ongoing research on quality in IS and CM is highly diverse and encompasses theoretical aspects including quality definition and quality models, and practical/empirical aspects such as the development of methods, approaches and tools for quality measurement and improvement. Current research on quality also includes quality characteristics definitions, validation instruments, methodological and development approaches to quality assurance during software and information systems development, quality monitors, quality assurance during information systems development processes and practices, quality assurance both for data and (meta)schemata, quality support for information systems data import and export, quality of query answering, and cost/benefit analysis of quality assurance processes. Quality assurance is also depending on the application area and the specific requirements in applications such as health sector, logistics, public sector, financial sector, manufacturing, services, e-commerce, software, etc. Furthermore, quality assurance must also be supported for data aggregation, ETL processes, web content management and other multi-layered applications. Quality assurance is typically requiring resources and has therefore beside its benefits a computational and economical trade-off. It is therefore also based on compromising between the value of quality data and the cost for quality assurance.
Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.
2013-01-01
Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789
Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H
2013-01-01
Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.
Master Pump Shutdown MPS Software Quality Assurance Plan (SQAP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
BEVINS, R.R.
2000-09-20
The MPSS Software Quality Assurance (SQAP) describes the tools and strategy used in the development of the MPSS software. The document also describes the methodology for controlling and managing changes to the software.
A software communication tool for the tele-ICU.
Pimintel, Denise M; Wei, Shang Heng; Odor, Alberto
2013-01-01
The Tele Intensive Care Unit (tele-ICU) supports a high volume, high acuity population of patients. There is a high-volume of incoming and outgoing calls, especially during the evening and night hours, through the tele-ICU hubs. The tele-ICU clinicians must be able to communicate effectively to team members in order to support the care of complex and critically ill patients while supporting and maintaining a standard to improve time to intervention. This study describes a software communication tool that will improve the time to intervention, over the paper-driven communication format presently used in the tele-ICU. The software provides a multi-relational database of message instances to mine information for evaluation and quality improvement for all entities that touch the tele-ICU. The software design incorporates years of critical care and software design experience combined with new skills acquired in an applied Health Informatics program. This software tool will function in the tele-ICU environment and perform as a front-end application that gathers, routes, and displays internal communication messages for intervention by priority and provider.
VennDIS: a JavaFX-based Venn and Euler diagram software to generate publication quality figures.
Ignatchenko, Vladimir; Ignatchenko, Alexandr; Sinha, Ankit; Boutros, Paul C; Kislinger, Thomas
2015-04-01
Venn diagrams are graphical representations of the relationships among multiple sets of objects and are often used to illustrate similarities and differences among genomic and proteomic datasets. All currently existing tools for producing Venn diagrams evince one of two traits; they require expertise in specific statistical software packages (such as R), or lack the flexibility required to produce publication-quality figures. We describe a simple tool that addresses both shortcomings, Venn Diagram Interactive Software (VennDIS), a JavaFX-based solution for producing highly customizable, publication-quality Venn, and Euler diagrams of up to five sets. The strengths of VennDIS are its simple graphical user interface and its large array of customization options, including the ability to modify attributes such as font, style and position of the labels, background color, size of the circle/ellipse, and outline color. It is platform independent and provides real-time visualization of figure modifications. The created figures can be saved as XML files for future modification or exported as high-resolution images for direct use in publications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Software Quality and Copyright: Issues in Computer-Assisted Instruction.
ERIC Educational Resources Information Center
Helm, Virginia
The two interconnected problems of educational quality and piracy are described and analyzed in this book, which begins with an investigation of the accusations regarding the alleged dismal quality of educational software. The reality behind accusations of rampant piracy and the effect of piracy on the quality of educational software is examined…
Software Quality Assurance Audits Guidebooks
NASA Technical Reports Server (NTRS)
1990-01-01
The growth in cost and importance of software to NASA has caused NASA to address the improvement of software development across the agency. One of the products of this program is a series of guidebooks that define a NASA concept of the assurance processes that are used in software development. The Software Assurance Guidebook, NASA-GB-A201, issued in September, 1989, provides an overall picture of the NASA concepts and practices in software assurance. Second level guidebooks focus on specific activities that fall within the software assurance discipline, and provide more detailed information for the manager and/or practitioner. This is the second level Software Quality Assurance Audits Guidebook that describes software quality assurance audits in a way that is compatible with practices at NASA Centers.
MapEdit: solution to continuous raster map creation
NASA Astrophysics Data System (ADS)
Rančić, Dejan; Djordjevi-Kajan, Slobodanka
2003-03-01
The paper describes MapEdit, MS Windows TM software for georeferencing and rectification of scanned paper maps. The software produces continuous raster maps which can be used as background in geographical information systems. Process of continuous raster map creation using MapEdit "mosaicking" function is also described as well as the georeferencing and rectification algorithms which are used in MapEdit. Our approach for georeferencing and rectification using four control points and two linear transformations for each scanned map part, together with nearest neighbor resampling method, represents low cost—high speed solution that produce continuous raster maps with satisfactory quality for many purposes (±1 pixel). Quality assessment of several continuous raster maps at different scales that have been created using our software and methodology, has been undertaken and results are presented in the paper. For the quality control of the produced raster maps we referred to three wide adopted standards: US Standard for Digital Cartographic Data, National Standard for Spatial Data Accuracy and US National Map Accuracy Standard. The results obtained during the quality assessment process are given in the paper and show that our maps meat all three standards.
Markov Chains For Testing Redundant Software
NASA Technical Reports Server (NTRS)
White, Allan L.; Sjogren, Jon A.
1990-01-01
Preliminary design developed for validation experiment that addresses problems unique to assuring extremely high quality of multiple-version programs in process-control software. Approach takes into account inertia of controlled system in sense it takes more than one failure of control program to cause controlled system to fail. Verification procedure consists of two steps: experimentation (numerical simulation) and computation, with Markov model for each step.
ERIC Educational Resources Information Center
Crowe, Suzy; Penney, Elaine
This book is the first volume in the "Kids and Computers" series, a series of books designed to help adults easily use high-quality, developmentally appropriate software with children. After reviewing the basics of selected software packages (how to start the program, stop the program, move around, and use special keys) several ideas and…
Software quality assurance | News
Measure was removed: "Sufficient level of detail in the requirements to develop test cases." ; This control measure was removed since the sufficient level of detail needed to develop test cases is recorded for all test cases. (Note: This is mandatory for applications graded with a High Quality Assurance
The impact of software quality characteristics on healthcare outcome: a literature review.
Aghazadeh, Sakineh; Pirnejad, Habibollah; Moradkhani, Alireza; Aliev, Alvosat
2014-01-01
The aim of this study was to discover the effect of software quality characteristics on healthcare quality and efficiency indicators. Through a systematic literature review, we selected and analyzed 37 original research papers to investigate the impact of the software indicators (coming from the standard ISO 9126 quality characteristics and sub-characteristics) on some of healthcare important outcome indicators and finally ranked these software indicators. The results showed that the software characteristics usability, reliability and efficiency were mostly favored in the studies, indicating their importance. On the other hand, user satisfaction, quality of patient care, clinical workflow efficiency, providers' communication and information exchange, patient satisfaction and care costs were among the healthcare outcome indicators frequently evaluated in relation to the mentioned software characteristics. Regression Logistic Method was the most common assessment methodology, and Confirmatory Factor Analysis and Structural Equation Modeling were performed to test the structural model's fit. The software characteristics were considered to impact the healthcare outcome indicators through other intermediate factors (variables).
NASA Technical Reports Server (NTRS)
Lawrence, Stella
1991-01-01
The object of this project was to develop and calibrate quantitative models for predicting the quality of software. Reliable flight and supporting ground software is a highly important factor in the successful operation of the space shuttle program. The models used in the present study consisted of SMERFS (Statistical Modeling and Estimation of Reliability Functions for Software). There are ten models in SMERFS. For a first run, the results obtained in modeling the cumulative number of failures versus execution time showed fairly good results for our data. Plots of cumulative software failures versus calendar weeks were made and the model results were compared with the historical data on the same graph. If the model agrees with actual historical behavior for a set of data then there is confidence in future predictions for this data. Considering the quality of the data, the models have given some significant results, even at this early stage. With better care in data collection, data analysis, recording of the fixing of failures and CPU execution times, the models should prove extremely helpful in making predictions regarding the future pattern of failures, including an estimate of the number of errors remaining in the software and the additional testing time required for the software quality to reach acceptable levels. It appears that there is no one 'best' model for all cases. It is for this reason that the aim of this project was to test several models. One of the recommendations resulting from this study is that great care must be taken in the collection of data. When using a model, the data should satisfy the model assumptions.
Cortegiani, Andrea; Russotto, Vincenzo; Montalto, Francesca; Iozzo, Pasquale; Meschis, Roberta; Pugliesi, Marinella; Mariano, Dario; Benenati, Vincenzo; Raineri, Santi Maurizio; Gregoretti, Cesare; Giarratano, Antonino
2017-01-01
High-quality chest compressions are pivotal to improve survival from cardiac arrest. Basic life support training of school students is an international priority. The aim of this trial was to assess the effectiveness of a real-time training software (Laerdal QCPR®) compared to a standard instructor-based feedback for chest compressions acquisition in secondary school students. After an interactive frontal lesson about basic life support and high quality chest compressions, 144 students were randomized to two types of chest compressions training: 1) using Laerdal QCPR® (QCPR group- 72 students) for real-time feedback during chest compressions with the guide of an instructor who considered software data for students' correction 2) based on standard instructor-based feedback (SF group- 72 students). Both groups had a minimum of a 2-minute chest compressions training session. Students were required to reach a minimum technical skill level before the evaluation. We evaluated all students at 7 days from the training with a 2-minute chest compressions session. The primary outcome was the compression score, which is an overall measure of chest compressions quality calculated by the software expressed as percentage. 125 students were present at the evaluation session (60 from QCPR group and 65 from SF group). Students in QCPR group had a significantly higher compression score (median 90%, IQR 81.9-96.0) compared to SF group (median 67%, IQR 27.7-87.5), p = 0.0003. Students in QCPR group performed significantly higher percentage of fully released chest compressions (71% [IQR 24.5-99.0] vs 24% [IQR 2.5-88.2]; p = 0.005) and better chest compression rate (117.5/min [IQR 106-123.5] vs 125/min [115-135.2]; p = 0.001). In secondary school students, a training for chest compressions based on a real-time feedback software (Laerdal QCPR®) guided by an instructor is superior to instructor-based feedback training in terms of chest compression technical skill acquisition. Australian New Zealand Clinical Trials Registry ACTRN12616000383460.
Zeng, G; Murphy, J; Annis, S-L; Wu, X; Wang, Y; McGowan, T; Macpherson, M
2012-07-01
To report a quality control program in prostate radiation therapy at our center that includes semi-automated planning process to generate high quality plans and in-house software to track plan quality in the subsequent clinical application. Arc planning in Eclipse v10.0 was preformed for both intact prostate and post-prostatectomy treatments. The planning focuses on DVH requirements and dose distributions being able to tolerate daily setup variations. A modified structure set is used to standardize the optimization, including short rectum and bladder in the fields to effectively tighten dose to target and a rectum expansion with 1cm cropped from PTV to block dose and shape posterior isodose lines. Structure, plan and optimization templates are used to streamline plan generation. DVH files are exported from Eclipse to a quality tracking software with GUI written in Matlab that can report the dose-volume data either for an individual patient or over a patient population. For 100 intact prostate patients treated with 78Gy, rectal D50, D25, D15 and D5 are 30.1±6.2Gy, 50.6±7.9Gy, 65.9±6.0Gy and 76.6±1.4Gy respectively, well below the limits 50Gy, 65Gy, 75Gy and 78Gy respectively. For prostate bed with prescription of 66Gy, rectal D50 is 35.9±6.9Gy. In both sites, PTV is covered by 95% prescription and the hotspots are less than 5%. The semi-automated planning method can efficiently create high quality plans while the tracking software can monitor the feedback from clinical application. It is a comprehensive and robust quality control program in radiation therapy. © 2012 American Association of Physicists in Medicine.
ERIC Educational Resources Information Center
Ichu, Emmanuel A.
2010-01-01
Software quality is perhaps one of the most sought-after attributes in product development, however; this goal is unattained. Problem factors in software development and how these have affected the maintainability of the delivered software systems requires a thorough investigation. It was, therefore, very important to understand software…
ERIC Educational Resources Information Center
Mitchell, Susan Marie
2012-01-01
Uncontrollable costs, schedule overruns, and poor end product quality continue to plague the software engineering field. Innovations formulated with the expectation to minimize or eliminate cost, schedule, and quality problems have generally fallen into one of three categories: programming paradigms, software tools, and software process…
An audit of half-count myocardial perfusion imaging using resolution recovery software.
Lawson, Richard S; White, Duncan; Nijran, Kuldip; Cade, Sarah C; Hall, David O; Kenny, Bob; Knight, Andy; Livieratos, Lefteris; Murray, Anthony; Towey, David
2014-05-01
The Nuclear Medicine Software Quality Group of the Institute of Physics and Engineering in Medicine has conducted a multicentre, multivendor audit to evaluate the use of resolution recovery software from several manufacturers when applied to myocardial perfusion data with half the normal counts acquired under a variety of clinical protocols in a range of departments. The objective was to determine whether centres could obtain clinical results with half-count data processed with resolution recovery software that were equivalent to those obtained using their normal protocols. Sixteen centres selected 50 routine myocardial perfusion studies each, from which the Nuclear Medicine Software Quality Group generated simulated half-count studies using Poisson resampling. These half-count studies were reconstructed using resolution recovery and the clinical reports compared with the original reports from the full-count data. A total of 769 patient studies were processed and compared. Eight centres found only a small number of clinically relevant discrepancies between the two reports, whereas eight had an unacceptably high number of discrepancies. There were no significant differences in acquisition parameters between the two groups, although centres finding a high number of discrepancies were more likely to perform both rest and stress scans on normal studies. Half of the participating centres could potentially make use of resolution recovery to reduce the administered activity for myocardial perfusion scans without changing their routine acquisition protocols. The other half could consider adjusting the reconstruction parameters used with their resolution recovery software if they wish to use reduced activity successfully.
NASA Astrophysics Data System (ADS)
Hol, J.; Wiebenga, J. H.; Carleer, B.
2017-09-01
In the stamping of automotive parts, friction and lubrication play a key role in achieving high quality products. In the development process of new automotive parts, it is therefore crucial to accurately account for these effects in sheet metal forming simulations. This paper presents a selection of results considering friction and lubrication modelling in sheet metal forming simulations of a front fender product. For varying lubrication conditions, the front fender can either show wrinkling or fractures. The front fender is modelled using different lubrication amounts, tool roughness’s and sheet coatings to show the strong influence of friction on both part quality and the overall production stability. For this purpose, the TriboForm software is used in combination with the AutoForm software. The results demonstrate that the TriboForm software enables the simulation of friction behaviour for varying lubrication conditions, i.e. resulting in a generally applicable approach for friction characterization under industrial sheet metal forming process conditions.
Kania-Richmond, Ania; Weeks, Laura; Scholten, Jeffrey; Reney, Mikaël
2016-03-01
Practice based research networks (PBRNs) are increasingly used as a tool for evidence based practice. We developed and tested the feasibility of using software to enable online collection of patient data within a chiropractic PBRN to support clinical decision making and research in participating clinics. To assess the feasibility of using online software to collect quality patient information. The study consisted of two phases: 1) Assessment of the quality of information provided, using a standardized form; and 2) Exploration of patients' perspectives and experiences regarding online information provision through semi-structured interviews. Data analysis was descriptive. Forty-five new patients were recruited. Thirty-six completed online forms, which were submitted by an appropriate person 100% of the time, with an error rate of less than 1%, and submitted in a timely manner 83% of the time. Twenty-one participants were interviewed. Overall, online forms were preferred given perceived security, ease of use, and enabling provision of more accurate information. Use of online software is feasible, provides high quality information, and is preferred by most participants. A pen-and-paper format should be available for patients with this preference and in case of technical difficulties.
Improvement of Computer Software Quality through Software Automated Tools.
1986-08-31
requirement for increased emphasis on software quality assurance has lead to the creation of various methods of verification and validation. Experience...result was a vast array of methods , systems, languages and automated tools to assist in the process. Given that the primary role of quality assurance is...Unfortunately, there is no single method , tool or technique that can insure accurate, reliable and cost effective software. Therefore, government and industry
Lee, Myungeun; Woo, Boyeong; Kuo, Michael D.; Jamshidi, Neema
2017-01-01
Objective The purpose of this study was to evaluate the reliability and quality of radiomic features in glioblastoma multiforme (GBM) derived from tumor volumes obtained with semi-automated tumor segmentation software. Materials and Methods MR images of 45 GBM patients (29 males, 16 females) were downloaded from The Cancer Imaging Archive, in which post-contrast T1-weighted imaging and fluid-attenuated inversion recovery MR sequences were used. Two raters independently segmented the tumors using two semi-automated segmentation tools (TumorPrism3D and 3D Slicer). Regions of interest corresponding to contrast-enhancing lesion, necrotic portions, and non-enhancing T2 high signal intensity component were segmented for each tumor. A total of 180 imaging features were extracted, and their quality was evaluated in terms of stability, normalized dynamic range (NDR), and redundancy, using intra-class correlation coefficients, cluster consensus, and Rand Statistic. Results Our study results showed that most of the radiomic features in GBM were highly stable. Over 90% of 180 features showed good stability (intra-class correlation coefficient [ICC] ≥ 0.8), whereas only 7 features were of poor stability (ICC < 0.5). Most first order statistics and morphometric features showed moderate-to-high NDR (4 > NDR ≥1), while above 35% of the texture features showed poor NDR (< 1). Features were shown to cluster into only 5 groups, indicating that they were highly redundant. Conclusion The use of semi-automated software tools provided sufficiently reliable tumor segmentation and feature stability; thus helping to overcome the inherent inter-rater and intra-rater variability of user intervention. However, certain aspects of feature quality, including NDR and redundancy, need to be assessed for determination of representative signature features before further development of radiomics. PMID:28458602
Lee, Myungeun; Woo, Boyeong; Kuo, Michael D; Jamshidi, Neema; Kim, Jong Hyo
2017-01-01
The purpose of this study was to evaluate the reliability and quality of radiomic features in glioblastoma multiforme (GBM) derived from tumor volumes obtained with semi-automated tumor segmentation software. MR images of 45 GBM patients (29 males, 16 females) were downloaded from The Cancer Imaging Archive, in which post-contrast T1-weighted imaging and fluid-attenuated inversion recovery MR sequences were used. Two raters independently segmented the tumors using two semi-automated segmentation tools (TumorPrism3D and 3D Slicer). Regions of interest corresponding to contrast-enhancing lesion, necrotic portions, and non-enhancing T2 high signal intensity component were segmented for each tumor. A total of 180 imaging features were extracted, and their quality was evaluated in terms of stability, normalized dynamic range (NDR), and redundancy, using intra-class correlation coefficients, cluster consensus, and Rand Statistic. Our study results showed that most of the radiomic features in GBM were highly stable. Over 90% of 180 features showed good stability (intra-class correlation coefficient [ICC] ≥ 0.8), whereas only 7 features were of poor stability (ICC < 0.5). Most first order statistics and morphometric features showed moderate-to-high NDR (4 > NDR ≥1), while above 35% of the texture features showed poor NDR (< 1). Features were shown to cluster into only 5 groups, indicating that they were highly redundant. The use of semi-automated software tools provided sufficiently reliable tumor segmentation and feature stability; thus helping to overcome the inherent inter-rater and intra-rater variability of user intervention. However, certain aspects of feature quality, including NDR and redundancy, need to be assessed for determination of representative signature features before further development of radiomics.
Idri, Ali; Bachiri, Mariam; Fernández-Alemán, José Luis
2016-03-01
Stakeholders' needs and expectations are identified by means of software quality requirements, which have an impact on software product quality. In this paper, we present a set of requirements for mobile personal health records (mPHRs) for pregnancy monitoring, which have been extracted from literature and existing mobile apps on the market. We also use the ISO/IEC 25030 standard to suggest the requirements that should be considered during the quality evaluation of these mPHRs. We then go on to design a checklist in which we contrast the mPHRs for pregnancy monitoring requirements with software product quality characteristics and sub-characteristics in order to calculate the impact of these requirements on software product quality, using the ISO/IEC 25010 software product quality standard. The results obtained show that the requirements related to the user's actions and the app's features have the most impact on the external sub-characteristics of the software product quality model. The only sub-characteristic affected by all the requirements is Appropriateness of Functional suitability. The characteristic Operability is affected by 95% of the requirements while the lowest degrees of impact were identified for Compatibility (15%) and Transferability (6%). Lastly, the degrees of the impact of the mPHRs for pregnancy monitoring requirements are discussed in order to provide appropriate recommendations for the developers and stakeholders of mPHRs for pregnancy monitoring.
Software Quality Metrics Enhancements. Volume 1
1980-04-01
the mathematical relationships which relate metrics to ratings of the various quality factors) for factors which were not validated previously were...function, provides a mathematical relationship between the metrics and the quality factors. (3) Validation of these normalization functions was performed by...samples, further research is needed before a high degree of confidence can be placed on the mathematical relationships established to date l (3.3.3) 6
Software quality: Process or people
NASA Technical Reports Server (NTRS)
Palmer, Regina; Labaugh, Modenna
1993-01-01
This paper will present data related to software development processes and personnel involvement from the perspective of software quality assurance. We examine eight years of data collected from six projects. Data collected varied by project but usually included defect and fault density with limited use of code metrics, schedule adherence, and budget growth information. The data are a blend of AFSCP 800-14 and suggested productivity measures in Software Metrics: A Practioner's Guide to Improved Product Development. A software quality assurance database tool, SQUID, was used to store and tabulate the data.
Cost Estimation of Software Development and the Implications for the Program Manager
1992-06-01
Software Lifecycle Model (SLIM), the Jensen System-4 model, the Software Productivity, Quality, and Reliability Estimator ( SPQR \\20), the Constructive...function models in current use are the Software Productivity, Quality, and Reliability Estimator ( SPQR /20) and the Software Architecture Sizing and...Estimator ( SPQR /20) was developed by T. Capers Jones of Software Productivity Research, Inc., in 1985. The model is intended to estimate the outcome
Recent development in software and automation tools for high-throughput discovery bioanalysis.
Shou, Wilson Z; Zhang, Jun
2012-05-01
Bioanalysis with LC-MS/MS has been established as the method of choice for quantitative determination of drug candidates in biological matrices in drug discovery and development. The LC-MS/MS bioanalytical support for drug discovery, especially for early discovery, often requires high-throughput (HT) analysis of large numbers of samples (hundreds to thousands per day) generated from many structurally diverse compounds (tens to hundreds per day) with a very quick turnaround time, in order to provide important activity and liability data to move discovery projects forward. Another important consideration for discovery bioanalysis is its fit-for-purpose quality requirement depending on the particular experiments being conducted at this stage, and it is usually not as stringent as those required in bioanalysis supporting drug development. These aforementioned attributes of HT discovery bioanalysis made it an ideal candidate for using software and automation tools to eliminate manual steps, remove bottlenecks, improve efficiency and reduce turnaround time while maintaining adequate quality. In this article we will review various recent developments that facilitate automation of individual bioanalytical procedures, such as sample preparation, MS/MS method development, sample analysis and data review, as well as fully integrated software tools that manage the entire bioanalytical workflow in HT discovery bioanalysis. In addition, software tools supporting the emerging high-resolution accurate MS bioanalytical approach are also discussed.
NASA Technical Reports Server (NTRS)
Basili, V. R.
1981-01-01
Work on metrics is discussed. Factors that affect software quality are reviewed. Metrics is discussed in terms of criteria achievements, reliability, and fault tolerance. Subjective and objective metrics are distinguished. Product/process and cost/quality metrics are characterized and discussed.
Software Requirements Analysis as Fault Predictor
NASA Technical Reports Server (NTRS)
Wallace, Dolores
2003-01-01
Waiting until the integration and system test phase to discover errors leads to more costly rework than resolving those same errors earlier in the lifecycle. Costs increase even more significantly once a software system has become operational. WE can assess the quality of system requirements, but do little to correlate this information either to system assurance activities or long-term reliability projections - both of which remain unclear and anecdotal. Extending earlier work on requirements accomplished by the ARM tool, measuring requirements quality information against code complexity and test data for the same system may be used to predict specific software modules containing high impact or deeply embedded faults now escaping in operational systems. Such knowledge would lead to more effective and efficient test programs. It may enable insight into whether a program should be maintained or started over.
Christner, Martin; Dressler, Dirk; Andrian, Mark; Reule, Claudia; Petrini, Orlando
2017-01-01
The fast and reliable characterization of bacterial and fungal pathogens plays an important role in infectious disease control and tracking of outbreak agents. DNA based methods are the gold standard for epidemiological investigations, but they are still comparatively expensive and time-consuming. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a fast, reliable and cost-effective technique now routinely used to identify clinically relevant human pathogens. It has been used for subspecies differentiation and typing, but its use for epidemiological tasks, e. g. for outbreak investigations, is often hampered by the complexity of data analysis. We have analysed publicly available MALDI-TOF mass spectra from a large outbreak of Shiga-Toxigenic Escherichia coli in northern Germany using a general purpose software tool for the analysis of complex biological data. The software was challenged with depauperate spectra and reduced learning group sizes to mimic poor spectrum quality and scarcity of reference spectra at the onset of an outbreak. With high quality formic acid extraction spectra, the software's built in classifier accurately identified outbreak related strains using as few as 10 reference spectra (99.8% sensitivity, 98.0% specificity). Selective variation of processing parameters showed impaired marker peak detection and reduced classification accuracy in samples with high background noise or artificially reduced peak counts. However, the software consistently identified mass signals suitable for a highly reliable marker peak based classification approach (100% sensitivity, 99.5% specificity) even from low quality direct deposition spectra. The study demonstrates that general purpose data analysis tools can effectively be used for the analysis of bacterial mass spectra.
SOA: A Quality Attribute Perspective
2011-06-23
in software engineering from CMU. 6June 2011 Twitter #seiwebinar © 2011 Carnegie Mellon University Agenda Service -Oriented Architecture and... Software Architecture: Review Service -Orientation and Quality Attributes Summary and Future Challenges 7June 2011 Twitter #seiwebinar © 2011...Architecture and Software Architecture: Review Service -Orientation and Quality Attributes Summary and Future Challenges Review 10June 2011 Twitter
QCScreen: a software tool for data quality control in LC-HRMS based metabolomics.
Simader, Alexandra Maria; Kluger, Bernhard; Neumann, Nora Katharina Nicole; Bueschl, Christoph; Lemmens, Marc; Lirk, Gerald; Krska, Rudolf; Schuhmacher, Rainer
2015-10-24
Metabolomics experiments often comprise large numbers of biological samples resulting in huge amounts of data. This data needs to be inspected for plausibility before data evaluation to detect putative sources of error e.g. retention time or mass accuracy shifts. Especially in liquid chromatography-high resolution mass spectrometry (LC-HRMS) based metabolomics research, proper quality control checks (e.g. for precision, signal drifts or offsets) are crucial prerequisites to achieve reliable and comparable results within and across experimental measurement sequences. Software tools can support this process. The software tool QCScreen was developed to offer a quick and easy data quality check of LC-HRMS derived data. It allows a flexible investigation and comparison of basic quality-related parameters within user-defined target features and the possibility to automatically evaluate multiple sample types within or across different measurement sequences in a short time. It offers a user-friendly interface that allows an easy selection of processing steps and parameter settings. The generated results include a coloured overview plot of data quality across all analysed samples and targets and, in addition, detailed illustrations of the stability and precision of the chromatographic separation, the mass accuracy and the detector sensitivity. The use of QCScreen is demonstrated with experimental data from metabolomics experiments using selected standard compounds in pure solvent. The application of the software identified problematic features, samples and analytical parameters and suggested which data files or compounds required closer manual inspection. QCScreen is an open source software tool which provides a useful basis for assessing the suitability of LC-HRMS data prior to time consuming, detailed data processing and subsequent statistical analysis. It accepts the generic mzXML format and thus can be used with many different LC-HRMS platforms to process both multiple quality control sample types as well as experimental samples in one or more measurement sequences.
CellProfiler Tracer: exploring and validating high-throughput, time-lapse microscopy image data.
Bray, Mark-Anthony; Carpenter, Anne E
2015-11-04
Time-lapse analysis of cellular images is an important and growing need in biology. Algorithms for cell tracking are widely available; what researchers have been missing is a single open-source software package to visualize standard tracking output (from software like CellProfiler) in a way that allows convenient assessment of track quality, especially for researchers tuning tracking parameters for high-content time-lapse experiments. This makes quality assessment and algorithm adjustment a substantial challenge, particularly when dealing with hundreds of time-lapse movies collected in a high-throughput manner. We present CellProfiler Tracer, a free and open-source tool that complements the object tracking functionality of the CellProfiler biological image analysis package. Tracer allows multi-parametric morphological data to be visualized on object tracks, providing visualizations that have already been validated within the scientific community for time-lapse experiments, and combining them with simple graph-based measures for highlighting possible tracking artifacts. CellProfiler Tracer is a useful, free tool for inspection and quality control of object tracking data, available from http://www.cellprofiler.org/tracer/.
High-quality remote interactive imaging in the operating theatre
NASA Astrophysics Data System (ADS)
Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan
2009-02-01
We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.
Improving Software Quality and Management Through Use of Service Level Agreements
2005-03-01
many who believe that the quality of the development process is the best predictor of software product quality. ( Fenton ) Repeatable software processes...reduced errors per KLOC for small projects ( Fenton ), and the quality management metric (QMM) (Machniak, Osmundson). There are also numerous IEEE 14...attention to cosmetic user interface issues and any problems that may arise with the prototype. (Sawyer) The validation process is also another check
Zaytsev, Yury V; Morrison, Abigail
2012-01-01
High quality neuroscience research requires accurate, reliable and well maintained neuroinformatics applications. As software projects become larger, offering more functionality and developing a denser web of interdependence between their component parts, we need more sophisticated methods to manage their complexity. If complexity is allowed to get out of hand, either the quality of the software or the speed of development suffer, and in many cases both. To address this issue, here we develop a scalable, low-cost and open source solution for continuous integration (CI), a technique which ensures the quality of changes to the code base during the development procedure, rather than relying on a pre-release integration phase. We demonstrate that a CI-based workflow, due to rapid feedback about code integration problems and tracking of code health measures, enabled substantial increases in productivity for a major neuroinformatics project and additional benefits for three further projects. Beyond the scope of the current study, we identify multiple areas in which CI can be employed to further increase the quality of neuroinformatics projects by improving development practices and incorporating appropriate development tools. Finally, we discuss what measures can be taken to lower the barrier for developers of neuroinformatics applications to adopt this useful technique.
Zaytsev, Yury V.; Morrison, Abigail
2013-01-01
High quality neuroscience research requires accurate, reliable and well maintained neuroinformatics applications. As software projects become larger, offering more functionality and developing a denser web of interdependence between their component parts, we need more sophisticated methods to manage their complexity. If complexity is allowed to get out of hand, either the quality of the software or the speed of development suffer, and in many cases both. To address this issue, here we develop a scalable, low-cost and open source solution for continuous integration (CI), a technique which ensures the quality of changes to the code base during the development procedure, rather than relying on a pre-release integration phase. We demonstrate that a CI-based workflow, due to rapid feedback about code integration problems and tracking of code health measures, enabled substantial increases in productivity for a major neuroinformatics project and additional benefits for three further projects. Beyond the scope of the current study, we identify multiple areas in which CI can be employed to further increase the quality of neuroinformatics projects by improving development practices and incorporating appropriate development tools. Finally, we discuss what measures can be taken to lower the barrier for developers of neuroinformatics applications to adopt this useful technique. PMID:23316158
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peck, T; Sparkman, D; Storch, N
''The LLNL Site-Specific Advanced Simulation and Computing (ASCI) Software Quality Engineering Recommended Practices VI.I'' document describes a set of recommended software quality engineering (SQE) practices for ASCI code projects at Lawrence Livermore National Laboratory (LLNL). In this context, SQE is defined as the process of building quality into software products by applying the appropriate guiding principles and management practices. Continual code improvement and ongoing process improvement are expected benefits. Certain practices are recommended, although projects may select the specific activities they wish to improve, and the appropriate time lines for such actions. Additionally, projects can rely on the guidance ofmore » this document when generating ASCI Verification and Validation (VSrV) deliverables. ASCI program managers will gather information about their software engineering practices and improvement. This information can be shared to leverage the best SQE practices among development organizations. It will further be used to ensure the currency and vitality of the recommended practices. This Overview is intended to provide basic information to the LLNL ASCI software management and development staff from the ''LLNL Site-Specific ASCI Software Quality Engineering Recommended Practices VI.I'' document. Additionally the Overview provides steps to using the ''LLNL Site-Specific ASCI Software Quality Engineering Recommended Practices VI.I'' document. For definitions of terminology and acronyms, refer to the Glossary and Acronyms sections in the ''LLNL Site-Specific ASCI Software Quality Engineering Recommended Practices VI.I''.« less
Testing and validation of computerized decision support systems.
Sailors, R M; East, T D; Wallace, C J; Carlson, D A; Franklin, M A; Heermann, L K; Kinder, A T; Bradshaw, R L; Randolph, A G; Morris, A H
1996-01-01
Systematic, through testing of decision support systems (DSSs) prior to release to general users is a critical aspect of high quality software design. Omission of this step may lead to the dangerous, and potentially fatal, condition of relying on a system with outputs of uncertain quality. Thorough testing requires a great deal of effort and is a difficult job because tools necessary to facilitate testing are not well developed. Testing is a job ill-suited to humans because it requires tireless attention to a large number of details. For these reasons, the majority of DSSs available are probably not well tested prior to release. We have successfully implemented a software design and testing plan which has helped us meet our goal of continuously improving the quality of our DSS software prior to release. While requiring large amounts of effort, we feel that the process of documenting and standardizing our testing methods are important steps toward meeting recognized national and international quality standards. Our testing methodology includes both functional and structural testing and requires input from all levels of development. Our system does not focus solely on meeting design requirements but also addresses the robustness of the system and the completeness of testing.
Petkewich, Matthew D.; Daamen, Ruby C.; Roehl, Edwin A.; Conrads, Paul
2016-09-29
The generation of Everglades Depth Estimation Network (EDEN) daily water-level and water-depth maps is dependent on high quality real-time data from over 240 water-level stations. To increase the accuracy of the daily water-surface maps, the Automated Data Assurance and Management (ADAM) tool was created by the U.S. Geological Survey as part of Greater Everglades Priority Ecosystems Science. The ADAM tool is used to provide accurate quality-assurance review of the real-time data from the EDEN network and allows estimation or replacement of missing or erroneous data. This user’s manual describes how to install and operate the ADAM software. File structure and operation of the ADAM software is explained using examples.
Guidelines for software inspections
NASA Technical Reports Server (NTRS)
1983-01-01
Quality control inspections are software problem finding procedures which provide defect removal as well as improvements in software functionality, maintenance, quality, and development and testing methodology is discussed. The many side benefits include education, documentation, training, and scheduling.
A Core Plug and Play Architecture for Reusable Flight Software Systems
NASA Technical Reports Server (NTRS)
Wilmot, Jonathan
2006-01-01
The Flight Software Branch, at Goddard Space Flight Center (GSFC), has been working on a run-time approach to facilitate a formal software reuse process. The reuse process is designed to enable rapid development and integration of high-quality software systems and to more accurately predict development costs and schedule. Previous reuse practices have been somewhat successful when the same teams are moved from project to project. But this typically requires taking the software system in an all-or-nothing approach where useful components cannot be easily extracted from the whole. As a result, the system is less flexible and scalable with limited applicability to new projects. This paper will focus on the rationale behind, and implementation of the run-time executive. This executive is the core for the component-based flight software commonality and reuse process adopted at Goddard.
Copyright and the Assurance of Quality Courseware.
ERIC Educational Resources Information Center
Helm, Virginia M.
Issues related to the illegal copying or piracy of educational software in the schools and its potential effect on quality software availability are discussed. Copyright violation is examined as a reason some software producers may be abandoning the school software market. An explanation of what the copyright allows and prohibits in terms of…
A survey of Canadian medical physicists: software quality assurance of in-house software.
Salomons, Greg J; Kelly, Diane
2015-01-05
This paper reports on a survey of medical physicists who write and use in-house written software as part of their professional work. The goal of the survey was to assess the extent of in-house software usage and the desire or need for related software quality guidelines. The survey contained eight multiple-choice questions, a ranking question, and seven free text questions. The survey was sent to medical physicists associated with cancer centers across Canada. The respondents to the survey expressed interest in having guidelines to help them in their software-related work, but also demonstrated extensive skills in the area of testing, safety, and communication. These existing skills form a basis for medical physicists to establish a set of software quality guidelines.
Impact of Requirements Quality on Project Success or Failure
NASA Astrophysics Data System (ADS)
Tamai, Tetsuo; Kamata, Mayumi Itakura
We are interested in the relationship between the quality of the requirements specifications for software projects and the subsequent outcome of the projects. To examine this relationship, we investigated 32 projects started and completed between 2003 and 2005 by the software development division of a large company in Tokyo. The company has collected reliable data on requirements specification quality, as evaluated by software quality assurance teams, and overall project performance data relating to cost and time overruns. The data for requirements specification quality were first converted into a multiple-dimensional space, with each dimension corresponding to an item of the recommended structure for software requirements specifications (SRS) defined in IEEE Std. 830-1998. We applied various statistical analysis methods to the SRS quality data and project outcomes.
Validation of a Quality Management Metric
2000-09-01
quality management metric (QMM) was used to measure the performance of ten software managers on Department of Defense (DoD) software development programs. Informal verification and validation of the metric compared the QMM score to an overall program success score for the entire program and yielded positive correlation. The results of applying the QMM can be used to characterize the quality of software management and can serve as a template to improve software management performance. Future work includes further refining the QMM, applying the QMM scores to provide feedback
A software quality model and metrics for risk assessment
NASA Technical Reports Server (NTRS)
Hyatt, L.; Rosenberg, L.
1996-01-01
A software quality model and its associated attributes are defined and used as the model for the basis for a discussion on risk. Specific quality goals and attributes are selected based on their importance to a software development project and their ability to be quantified. Risks that can be determined by the model's metrics are identified. A core set of metrics relating to the software development process and its products is defined. Measurements for each metric and their usability and applicability are discussed.
Xyce parallel electronic simulator design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornquist, Heidi K.; Rankin, Eric Lamont; Mei, Ting
2010-09-01
This document is the Xyce Circuit Simulator developer guide. Xyce has been designed from the 'ground up' to be a SPICE-compatible, distributed memory parallel circuit simulator. While it is in many respects a research code, Xyce is intended to be a production simulator. As such, having software quality engineering (SQE) procedures in place to insure a high level of code quality and robustness are essential. Version control, issue tracking customer support, C++ style guildlines and the Xyce release process are all described. The Xyce Parallel Electronic Simulator has been under development at Sandia since 1999. Historically, Xyce has mostly beenmore » funded by ASC, the original focus of Xyce development has primarily been related to circuits for nuclear weapons. However, this has not been the only focus and it is expected that the project will diversify. Like many ASC projects, Xyce is a group development effort, which involves a number of researchers, engineers, scientists, mathmaticians and computer scientists. In addition to diversity of background, it is to be expected on long term projects for there to be a certain amount of staff turnover, as people move on to different projects. As a result, it is very important that the project maintain high software quality standards. The point of this document is to formally document a number of the software quality practices followed by the Xyce team in one place. Also, it is hoped that this document will be a good source of information for new developers.« less
The design of real time infrared image generation software based on Creator and Vega
NASA Astrophysics Data System (ADS)
Wang, Rui-feng; Wu, Wei-dong; Huo, Jun-xiu
2013-09-01
Considering the requirement of high reality and real-time quality dynamic infrared image of an infrared image simulation, a method to design real-time infrared image simulation application on the platform of VC++ is proposed. This is based on visual simulation software Creator and Vega. The functions of Creator are introduced simply, and the main features of Vega developing environment are analyzed. The methods of infrared modeling and background are offered, the designing flow chart of the developing process of IR image real-time generation software and the functions of TMM Tool and MAT Tool and sensor module are explained, at the same time, the real-time of software is designed.
cFE/CFS (Core Flight Executive/Core Flight System)
NASA Technical Reports Server (NTRS)
Wildermann, Charles P.
2008-01-01
This viewgraph presentation describes in detail the requirements and goals of the Core Flight Executive (cFE) and the Core Flight System (CFS). The Core Flight Software System is a mission independent, platform-independent, Flight Software (FSW) environment integrating a reusable core flight executive (cFE). The CFS goals include: 1) Reduce time to deploy high quality flight software; 2) Reduce project schedule and cost uncertainty; 3) Directly facilitate formalized software reuse; 4) Enable collaboration across organizations; 5) Simplify sustaining engineering (AKA. FSW maintenance); 6) Scale from small instruments to System of Systems; 7) Platform for advanced concepts and prototyping; and 7) Common standards and tools across the branch and NASA wide.
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J. (Editor)
2008-01-01
The Guidance and Control Software (GCS) project was the last in a series of software reliability studies conducted at Langley Research Center between 1977 and 1994. The technical results of the GCS project were recorded after the experiment was completed. Some of the support documentation produced as part of the experiment, however, is serving an unexpected role far beyond its original project context. Some of the software used as part of the GCS project was developed to conform to the RTCA/DO-178B software standard, "Software Considerations in Airborne Systems and Equipment Certification," used in the civil aviation industry. That standard requires extensive documentation throughout the software development life cycle, including plans, software requirements, design and source code, verification cases and results, and configuration management and quality control data. The project documentation that includes this information is open for public scrutiny without the legal or safety implications associated with comparable data from an avionics manufacturer. This public availability has afforded an opportunity to use the GCS project documents for DO-178B training. This report provides a brief overview of the GCS project, describes the 4-volume set of documents and the role they are playing in training, and includes configuration management and quality assurance documents from the GCS project. Volume 4 contains six appendices: A. Software Accomplishment Summary for the Guidance and Control Software Project; B. Software Configuration Index for the Guidance and Control Software Project; C. Configuration Management Records for the Guidance and Control Software Project; D. Software Quality Assurance Records for the Guidance and Control Software Project; E. Problem Report for the Pluto Implementation of the Guidance and Control Software Project; and F. Support Documentation Change Reports for the Guidance and Control Software Project.
Kania-Richmond, Ania; Weeks, Laura; Scholten, Jeffrey; Reney, Mikaël
2016-01-01
Background: Practice based research networks (PBRNs) are increasingly used as a tool for evidence based practice. We developed and tested the feasibility of using software to enable online collection of patient data within a chiropractic PBRN to support clinical decision making and research in participating clinics. Purpose: To assess the feasibility of using online software to collect quality patient information. Methods: The study consisted of two phases: 1) Assessment of the quality of information provided, using a standardized form; and 2) Exploration of patients’ perspectives and experiences regarding online information provision through semi-structured interviews. Data analysis was descriptive. Results: Forty-five new patients were recruited. Thirty-six completed online forms, which were submitted by an appropriate person 100% of the time, with an error rate of less than 1%, and submitted in a timely manner 83% of the time. Twenty-one participants were interviewed. Overall, online forms were preferred given perceived security, ease of use, and enabling provision of more accurate information. Conclusions: Use of online software is feasible, provides high quality information, and is preferred by most participants. A pen-and-paper format should be available for patients with this preference and in case of technical difficulties. PMID:27069272
NASA Astrophysics Data System (ADS)
Gunawan, D.; Amalia, A.; Rahmat, R. F.; Muchtar, M. A.; Siregar, I.
2018-02-01
Identification of software maturity level is a technique to determine the quality of the software. By identifying the software maturity level, the weaknesses of the software can be observed. As a result, the recommendations might be a reference for future software maintenance and development. This paper discusses the software Capability Level (CL) with case studies on Quality Management Unit (Unit Manajemen Mutu) University of Sumatera Utara (UMM-USU). This research utilized Standard CMMI Appraisal Method for Process Improvement class C (SCAMPI C) model with continuous representation. This model focuses on activities for developing quality products and services. The observation is done in three process areas, such as Project Planning (PP), Project Monitoring and Control (PMC), and Requirements Management (REQM). According to the measurement of software capability level for UMM-USU software, turns out that the capability level for the observed process area is in the range of CL1 and CL2. Planning Project (PP) is the only process area which reaches capability level 2, meanwhile, PMC and REQM are still in CL 1 or in performed level. This research reveals several weaknesses of existing UMM-USU software. Therefore, this study proposes several recommendations for UMM-USU to improve capability level for observed process areas.
Dickerson, Jane A; Schmeling, Michael; Hoofnagle, Andrew N; Hoffman, Noah G
2013-01-16
Mass spectrometry provides a powerful platform for performing quantitative, multiplexed assays in the clinical laboratory, but at the cost of increased complexity of analysis and quality assurance calculations compared to other methodologies. Here we describe the design and implementation of a software application that performs quality control calculations for a complex, multiplexed, mass spectrometric analysis of opioids and opioid metabolites. The development and implementation of this application improved our data analysis and quality assurance processes in several ways. First, use of the software significantly improved the procedural consistency for performing quality control calculations. Second, it reduced the amount of time technologists spent preparing and reviewing the data, saving on average over four hours per run, and in some cases improving turnaround time by a day. Third, it provides a mechanism for coupling procedural and software changes with the results of each analysis. We describe several key details of the implementation including the use of version control software and automated unit tests. These generally useful software engineering principles should be considered for any software development project in the clinical lab. Copyright © 2012 Elsevier B.V. All rights reserved.
From Exotic to Mainstream: A 10-year Odyssey from Internet Speed to Boundary Spanning with Scrum
NASA Astrophysics Data System (ADS)
Baskerville, Richard; Pries-Heje, Jan; Madsen, Sabine
Based on four empirical studies conducted over a 10-year time period from 1999 to 2008 we investigate how local software processes interact with global changes in the software development context. In 1999 companies were developing software at high speed in a desperate rush to be first-to-market. In 2001 a new high speed/quick results development process had become established practice. In 2003 changes in the market created the need for a more balanced view on speed and quality, and in 2008 companies were successfully combining agile and plan driven approaches to achieve the benefits of both. The studies reveal a twostage pattern in which dramatic changes in the market causes disruption of established practices, experimentation, and process adaptations followed by consolidation of lessons learnt into a new (and once again mature) software development process. Limitations, implications, and areas for future research are discussed.
NASA PC software evaluation project
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Kuan, Julie C.
1986-01-01
The USL NASA PC software evaluation project is intended to provide a structured framework for facilitating the development of quality NASA PC software products. The project will assist NASA PC development staff to understand the characteristics and functions of NASA PC software products. Based on the results of the project teams' evaluations and recommendations, users can judge the reliability, usability, acceptability, maintainability and customizability of all the PC software products. The objective here is to provide initial, high-level specifications and guidelines for NASA PC software evaluation. The primary tasks to be addressed in this project are as follows: to gain a strong understanding of what software evaluation entails and how to organize a structured software evaluation process; to define a structured methodology for conducting the software evaluation process; to develop a set of PC software evaluation criteria and evaluation rating scales; and to conduct PC software evaluations in accordance with the identified methodology. Communication Packages, Network System Software, Graphics Support Software, Environment Management Software, General Utilities. This report represents one of the 72 attachment reports to the University of Southwestern Louisiana's Final Report on NASA Grant NGT-19-010-900. Accordingly, appropriate care should be taken in using this report out of context of the full Final Report.
Software technology insertion: A study of success factors
NASA Technical Reports Server (NTRS)
Lydon, Tom
1990-01-01
Managing software development in large organizations has become increasingly difficult due to increasing technical complexity, stricter government standards, a shortage of experienced software engineers, competitive pressure for improved productivity and quality, the need to co-develop hardware and software together, and the rapid changes in both hardware and software technology. The 'software factory' approach to software development minimizes risks while maximizing productivity and quality through standardization, automation, and training. However, in practice, this approach is relatively inflexible when adopting new software technologies. The methods that a large multi-project software engineering organization can use to increase the likelihood of successful software technology insertion (STI), especially in a standardized engineering environment, are described.
A NASA-wide approach toward cost-effective, high-quality software through reuse
NASA Technical Reports Server (NTRS)
Scheper, Charlotte O. (Editor); Smith, Kathryn A. (Editor)
1993-01-01
NASA Langley Research Center sponsored the second Workshop on NASA Research in Software Reuse on May 5-6, 1992 at the Research Triangle Park, North Carolina. The workshop was hosted by the Research Triangle Institute. Participants came from the three NASA centers, four NASA contractor companies, two research institutes and the Air Force's Rome Laboratory. The purpose of the workshop was to exchange information on software reuse tool development, particularly with respect to tool needs, requirements, and effectiveness. The participants presented the software reuse activities and tools being developed and used by their individual centers and programs. These programs address a wide range of reuse issues. The group also developed a mission and goals for software reuse within NASA. This publication summarizes the presentations and the issues discussed during the workshop.
Requirements model for an e-Health awareness portal
NASA Astrophysics Data System (ADS)
Hussain, Azham; Mkpojiogu, Emmanuel O. C.; Nawi, Mohd Nasrun M.
2016-08-01
Requirements engineering is at the heart and foundation of software engineering process. Poor quality requirements inevitably lead to poor quality software solutions. Also, poor requirement modeling is tantamount to designing a poor quality product. So, quality assured requirements development collaborates fine with usable products in giving the software product the needed quality it demands. In the light of the foregoing, the requirements for an e-Ebola Awareness Portal were modeled with a good attention given to these software engineering concerns. The requirements for the e-Health Awareness Portal are modeled as a contribution to the fight against Ebola and helps in the fulfillment of the United Nation's Millennium Development Goal No. 6. In this study requirements were modeled using UML 2.0 modeling technique.
NASA Technical Reports Server (NTRS)
1995-01-01
The Formal Methods Specification and Verification Guidebook for Software and Computer Systems describes a set of techniques called Formal Methods (FM), and outlines their use in the specification and verification of computer systems and software. Development of increasingly complex systems has created a need for improved specification and verification techniques. NASA's Safety and Mission Quality Office has supported the investigation of techniques such as FM, which are now an accepted method for enhancing the quality of aerospace applications. The guidebook provides information for managers and practitioners who are interested in integrating FM into an existing systems development process. Information includes technical and administrative considerations that must be addressed when establishing the use of FM on a specific project. The guidebook is intended to aid decision makers in the successful application of FM to the development of high-quality systems at reasonable cost. This is the first volume of a planned two-volume set. The current volume focuses on administrative and planning considerations for the successful application of FM.
Software quality assurance plan for GCS
NASA Technical Reports Server (NTRS)
Duncan, Stephen E.; Bailey, Elizabeth K.
1990-01-01
The software quality assurance (SQA) function for the Guidance and Control Software (GCS) project which is part of a software error studies research program is described. The SQA plan outlines all of the procedures, controls, and audits to be carried out by the SQA organization to ensure adherence to the policies, procedures, and standards for the GCS project.
Enhancing Environmental HPC Applications: The EnCompAS approach
NASA Astrophysics Data System (ADS)
Frank, Anton; Donners, John; Pursula, Antti; Seinstra, Frank; Kranzlmüller, Dieter
2015-04-01
Many HPC applications in geoscience are of very high scientific quality and highly optimized for supercomputers. However, some of these codes lack the uptake by other adjacent scientific communities or industry due to deficiencies in usability, quality, and availability. Since enhancing software by, e.g., adding a graphical user interface, respecting data standards, setting up a support structure, or writing an extensive documentation is not of direct and immediate scientific relevance, most developers are not willing to invest any additional effort in these issues. Furthermore, if scientists, who are not directly involved in the development of some scientific software, could make benefit from additional features or interfaces, respective requests are often turned down due to the lack of time and resources. On the other hand, such enhancements are crucial for the sustainability of the scientific assets as well as the widespread or even worldwide distribution of European environmental software. Closely collaborating with environmental scientists the national supercomputing and eScience centres in Helsinki, Amsterdam, and Munich have identified that an enhancement of HPC and data analysis software must be provided as a service to the scientists developing such software. Therefore, first steps have been taken to establish respective services at these centres. In this talk we will present the already existing and envisioned service portfolio, some first success stories, and the approach to harmonize the current status aiming to turn this local effort into a pan-European service offering for environmental science.
A fouling monitor alarm to prevent forced outages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, R.E.; Hickinbotham, A.; Fang, T.C.
2000-07-01
Many utilities rely on coal blending to meet emissions and boiler performance goals, but the increased variability in coal quality can adversely impact ash deposition and soot blowing requirements. Other utilities are experimenting with lower quality coals and burner zone blending of coals fired from different bunkers as part of a deregulation strategy to reduce fuel costs. However, these strategies can lead to slagging/fouling episodes, a possible outage, or a decrease in unit availability if boiler operations are not carefully monitored. This paper summarizes the development of software to monitor boiler fouling and to provide an advanced warning to themore » control operators when a fouling episode is imminent. With adequate warming, preemptive action can be taken (e.g., soot blowing, a change in coal blend, etc.) to potentially avoid a costly outage. The software utilizes a unique combination of combustion diagnostic techniques and convective section heat adsorption analyses to identify boiler operating conditions where ash deposition rates may be high and conductive to triggering a fouling episode. The paper outlines the history of the fouling problem and the implementation of the software on Wabamun Unit 4, a tangentially-fired unit with relatively narrow reheat tube spacing. The unit had a tendency to foul when burning a high alkaline (but low ash) coal seam. The paper discusses the software development, implementation, and data acquisitions activities. Preliminary test results are provided for Wabamun 4 and for Sundance Units 1 and 2 where the software was recently installed.« less
Zhu, Yun; Lao, Yanwen; Jang, Carey; Lin, Chen-Jen; Xing, Jia; Wang, Shuxiao; Fu, Joshua S; Deng, Shuang; Xie, Junping; Long, Shicheng
2015-01-01
This article describes the development and implementations of a novel software platform that supports real-time, science-based policy making on air quality through a user-friendly interface. The software, RSM-VAT, uses a response surface modeling (RSM) methodology and serves as a visualization and analysis tool (VAT) for three-dimensional air quality data obtained by atmospheric models. The software features a number of powerful and intuitive data visualization functions for illustrating the complex nonlinear relationship between emission reductions and air quality benefits. The case study of contiguous U.S. demonstrates that the enhanced RSM-VAT is capable of reproducing the air quality model results with Normalized Mean Bias <2% and assisting in air quality policy making in near real time. Copyright © 2014. Published by Elsevier B.V.
Comparison of in-hospital versus 30-day mortality assessments for selected medical conditions.
Borzecki, Ann M; Christiansen, Cindy L; Chew, Priscilla; Loveland, Susan; Rosen, Amy K
2010-12-01
In-hospital mortality measures such as the Agency for Healthcare Research and Quality (AHRQ) Inpatient Quality Indicators (IQIs) are easily derived using hospital discharge abstracts and publicly available software. However, hospital assessments based on a 30-day postadmission interval might be more accurate given potential differences in facility discharge practices. To compare in-hospital and 30-day mortality rates for 6 medical conditions using the AHRQ IQI software. We used IQI software (v3.1) and 2004-2007 Veterans Health Administration (VA) discharge and Vital Status files to derive 4-year facility-level in-hospital and 30-day observed mortality rates and observed/expected ratios (O/Es) for admissions with a principal diagnosis of acute myocardial infarction, congestive heart failure, stroke, gastrointestinal hemorrhage, hip fracture, and pneumonia. We standardized software-calculated O/Es to the VA population and compared O/Es and outlier status across sites using correlation, observed agreement, and kappas. Of 119 facilities, in-hospital versus 30-day mortality O/E correlations were generally high (median: r = 0.78; range: 0.31-0.86). Examining outlier status, observed agreement was high (median: 84.7%, 80.7%-89.1%). Kappas showed at least moderate agreement (k > 0.40) for all indicators except stroke and hip fracture (k ≤ 0.22). Across indicators, few sites changed from a high to nonoutlier or low outlier, or vice versa (median: 10, range: 7-13). The AHRQ IQI software can be easily adapted to generate 30-day mortality rates. Although 30-day mortality has better face validity as a hospital performance measure than in-hospital mortality, site assessments were similar despite the definition used. Thus, the measure selected for internal benchmarking should primarily depend on the healthcare system's data linkage capabilities.
The new meaning of quality in the information age.
Prahalad, C K; Krishnan, M S
1999-01-01
Software applications are now a mission-critical source of competitive advantage for most companies. They are also a source of great risk, as the Y2K bug has made clear. Yet many line managers still haven't confronted software issues--partly because they aren't sure how best to define the quality of the applications in their IT infrastructures. Some companies such as Wal-Mart and the Gap have successfully integrated the software in their networks, but most have accumulated an unwidely number of incompatible applications--all designed to perform the same tasks. The authors provide a framework for measuring the performance of software in a company's IT portfolio. Quality traditionally has been measured according to a product's ability to meet certain specifications; other views of quality have emerged that measure a product's adaptability to customers' needs and a product's ability to encourage innovation. To judge software quality properly, argue the authors, managers must measure applications against all three approaches. Understanding the domain of a software application is an important part of that process. The domain is the body of knowledge about a user's needs and expectations for a product. Software domains change frequently based on how a consumer chooses to use, for example, Microsoft Word or a spreadsheet application. The domain can also be influenced by general changes in technology, such as the development of a new software platform. Thus, applications can't be judged only according to whether they conform to specifications. The authors discuss how to identify domain characteristics and software risks and suggest ways to reduce the variability of software domains.
Standardized development of computer software. Part 1: Methods
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1976-01-01
This work is a two-volume set on standards for modern software engineering methodology. This volume presents a tutorial and practical guide to the efficient development of reliable computer software, a unified and coordinated discipline for design, coding, testing, documentation, and project organization and management. The aim of the monograph is to provide formal disciplines for increasing the probability of securing software that is characterized by high degrees of initial correctness, readability, and maintainability, and to promote practices which aid in the consistent and orderly development of a total software system within schedule and budgetary constraints. These disciplines are set forth as a set of rules to be applied during software development to drastically reduce the time traditionally spent in debugging, to increase documentation quality, to foster understandability among those who must come in contact with it, and to facilitate operations and alterations of the program as requirements on the program environment change.
North, Frederick; Varkey, Prathiba; Caraballo, Pedro; Vsetecka, Darlene; Bartel, Greg
2007-10-11
Complex decision support software can require significant effort in maintenance and enhancement. A quality improvement tool, the prioritization matrix, was successfully used to guide software enhancement of algorithms in a symptom assessment call center.
Measuring the impact of computer resource quality on the software development process and product
NASA Technical Reports Server (NTRS)
Mcgarry, Frank; Valett, Jon; Hall, Dana
1985-01-01
The availability and quality of computer resources during the software development process was speculated to have measurable, significant impact on the efficiency of the development process and the quality of the resulting product. Environment components such as the types of tools, machine responsiveness, and quantity of direct access storage may play a major role in the effort to produce the product and in its subsequent quality as measured by factors such as reliability and ease of maintenance. During the past six years, the NASA Goddard Space Flight Center has conducted experiments with software projects in an attempt to better understand the impact of software development methodologies, environments, and general technologies on the software process and product. Data was extracted and examined from nearly 50 software development projects. All were related to support of satellite flight dynamics ground-based computations. The relationship between computer resources and the software development process and product as exemplified by the subject NASA data was examined. Based upon the results, a number of computer resource-related implications are provided.
2013-01-01
Background Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists’ capacity to use these immunoassays to evaluate human clinical trials. Results The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose–response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Conclusions Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license. PMID:23631706
Eckels, Josh; Nathe, Cory; Nelson, Elizabeth K; Shoemaker, Sara G; Nostrand, Elizabeth Van; Yates, Nicole L; Ashley, Vicki C; Harris, Linda J; Bollenbeck, Mark; Fong, Youyi; Tomaras, Georgia D; Piehler, Britt
2013-04-30
Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists' capacity to use these immunoassays to evaluate human clinical trials. The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose-response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license.
Water Quality Analysis Tool (WQAT) | Science Inventory | US ...
The purpose of the Water Quality Analysis Tool (WQAT) software is to provide a means for analyzing and producing useful remotely sensed data products for an entire estuary, a particular point or area of interest (AOI or POI) in estuaries, or water bodies of interest where pre-processed and geographically gridded remotely sensed images are available. A graphical user interface (GUI), was created to enable the user to select and display imagery from a variety of remote sensing data sources. The user can select a date (or date range) and location to extract pixels from the remotely sensed imagery. The GUI is used to obtain all available pixel values (i.e. pixel from all available bands of all available satellites) for a given location on a given date and time. The resultant data set can be analyzed or saved to a file for future use. The WQAT software provides users with a way to establish algorithms between remote sensing reflectance (Rrs) and any available in situ parameters, as well as statistical and regression analysis. The combined data sets can be used to improve water quality research and studies. Satellites provide spatially synoptic data at high frequency (daily to weekly). These characteristics are desirable for supplementing existing water quality observations and for providing information for large aquatic ecosystems that are historically under-sampled by field programs. Thus, the Water Quality Assessment Tool (WQAT) software tool was developed to suppo
How Reuse Influences Productivity in Object-Oriented Systems
NASA Technical Reports Server (NTRS)
Basili, Victor R.; Briand, Lionel C.; Melo, Walcelio L.
1997-01-01
Although reuse is assumed to be especially valuable in building high quality software as well as in Object Oriented (OO) development, limited empirical evidence connects reuse with productivity and quality gains. The author's eight system study begins to define such benefits in an OO framework, most notably in terms of reduce defect density and rework as well as in increased productivity.
NASA Technical Reports Server (NTRS)
Miller, Sharon E.; Tucker, George T.; Verducci, Anthony J., Jr.
1992-01-01
Software process assessments (SPA's) are part of an ongoing program of continuous quality improvements in AT&T. Their use was found to be very beneficial by software development organizations in identifying the issues facing the organization and the actions required to increase both quality and productivity in the organization.
SU-F-J-72: A Clinical Usable Integrated Contouring Quality Evaluation Software for Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, S; Dolly, S; Cai, B
Purpose: To introduce the Auto Contour Evaluation (ACE) software, which is the clinical usable, user friendly, efficient and all-in-one toolbox for automatically identify common contouring errors in radiotherapy treatment planning using supervised machine learning techniques. Methods: ACE is developed with C# using Microsoft .Net framework and Windows Presentation Foundation (WPF) for elegant GUI design and smooth GUI transition animations through the integration of graphics engines and high dots per inch (DPI) settings on modern high resolution monitors. The industrial standard software design pattern, Model-View-ViewModel (MVVM) pattern, is chosen to be the major architecture of ACE for neat coding structure, deepmore » modularization, easy maintainability and seamless communication with other clinical software. ACE consists of 1) a patient data importing module integrated with clinical patient database server, 2) a 2D DICOM image and RT structure simultaneously displaying module, 3) a 3D RT structure visualization module using Visualization Toolkit or VTK library and 4) a contour evaluation module using supervised pattern recognition algorithms to detect contouring errors and display detection results. ACE relies on supervised learning algorithms to handle all image processing and data processing jobs. Implementations of related algorithms are powered by Accord.Net scientific computing library for better efficiency and effectiveness. Results: ACE can take patient’s CT images and RT structures from commercial treatment planning software via direct user input or from patients’ database. All functionalities including 2D and 3D image visualization and RT contours error detection have been demonstrated with real clinical patient cases. Conclusion: ACE implements supervised learning algorithms and combines image processing and graphical visualization modules for RT contours verification. ACE has great potential for automated radiotherapy contouring quality verification. Structured with MVVM pattern, it is highly maintainable and extensible, and support smooth connections with other clinical software tools.« less
Architecture of a framework for providing information services for public transport.
García, Carmelo R; Pérez, Ricardo; Lorenzo, Alvaro; Quesada-Arencibia, Alexis; Alayón, Francisco; Padrón, Gabino
2012-01-01
This paper presents OnRoute, a framework for developing and running ubiquitous software that provides information services to passengers of public transportation, including payment systems and on-route guidance services. To achieve a high level of interoperability, accessibility and context awareness, OnRoute uses the ubiquitous computing paradigm. To guarantee the quality of the software produced, the reliable software principles used in critical contexts, such as automotive systems, are also considered by the framework. The main components of its architecture (run-time, system services, software components and development discipline) and how they are deployed in the transportation network (stations and vehicles) are described in this paper. Finally, to illustrate the use of OnRoute, the development of a guidance service for travellers is explained.
ERIC Educational Resources Information Center
Lee, Victor R.
2015-01-01
Biomechanics, and specifically the biomechanics associated with human movement, is a potentially rich backdrop against which educators can design innovative science teaching and learning activities. Moreover, the use of technologies associated with biomechanics research, such as high-speed cameras that can produce high-quality slow-motion video,…
Predicting Software Assurance Using Quality and Reliability Measures
2014-12-01
errors are not found in unit testing . The rework effort to correct requirement and design problems in later phases can be as high as 300 to 1,000...Literature 31 Appendix B: Quality Cannot Be Tested In 35 Bibliography 38 CMU/SEI-2014-TN-026 | ii CMU/SEI-2014-TN-026 | iii List of Figures...Removal Densities During Development 10 Figure 8: Quality and Security-Focused Workflow 14 Figure 9: Testing Reliability Results for the Largest Project
15 CFR 995.25 - Quality management system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... management system are those defined in this part. The quality management system must ensure that the... type approved conversion software is maintained by a third party, CEVAD shall ensure that no changes made to the conversion software render the type approval of the conversion software invalid, and shall...
15 CFR 995.25 - Quality management system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... management system are those defined in this part. The quality management system must ensure that the... type approved conversion software is maintained by a third party, CEVAD shall ensure that no changes made to the conversion software render the type approval of the conversion software invalid, and shall...
15 CFR 995.25 - Quality management system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... management system are those defined in this part. The quality management system must ensure that the... type approved conversion software is maintained by a third party, CEVAD shall ensure that no changes made to the conversion software render the type approval of the conversion software invalid, and shall...
15 CFR 995.25 - Quality management system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... management system are those defined in this part. The quality management system must ensure that the... type approved conversion software is maintained by a third party, CEVAD shall ensure that no changes made to the conversion software render the type approval of the conversion software invalid, and shall...
NASA Astrophysics Data System (ADS)
Tokareva, Victoria
2018-04-01
New generation medicine demands a better quality of analysis increasing the amount of data collected during checkups, and simultaneously decreasing the invasiveness of a procedure. Thus it becomes urgent not only to develop advanced modern hardware, but also to implement special software infrastructure for using it in everyday clinical practice, so-called Picture Archiving and Communication Systems (PACS). Developing distributed PACS is a challenging task for nowadays medical informatics. The paper discusses the architecture of distributed PACS server for processing large high-quality medical images, with respect to technical specifications of modern medical imaging hardware, as well as international standards in medical imaging software. The MapReduce paradigm is proposed for image reconstruction by server, and the details of utilizing the Hadoop framework for this task are being discussed in order to provide the design of distributed PACS as ergonomic and adapted to the needs of end users as possible.
Software Design Improvements. Part 2; Software Quality and the Design and Inspection Process
NASA Technical Reports Server (NTRS)
Lalli, Vincent R.; Packard, Michael H.; Ziemianski, Tom
1997-01-01
The application of assurance engineering techniques improves the duration of failure-free performance of software. The totality of features and characteristics of a software product are what determine its ability to satisfy customer needs. Software in safety-critical systems is very important to NASA. We follow the System Safety Working Groups definition for system safety software as: 'The optimization of system safety in the design, development, use and maintenance of software and its integration with safety-critical systems in an operational environment. 'If it is not safe, say so' has become our motto. This paper goes over methods that have been used by NASA to make software design improvements by focusing on software quality and the design and inspection process.
Establishing Quantitative Software Metrics in Department of the Navy Programs
2016-04-01
13 Quality to Metrics Dependency Matrix...11 7. Quality characteristics to metrics dependecy matrix...In accomplishing this goal, a need exists for a formalized set of software quality metrics . This document establishes the validity of those necessary
A Procedure for High Resolution Satellite Imagery Quality Assessment
Crespi, Mattia; De Vendictis, Laura
2009-01-01
Data products generated from High Resolution Satellite Imagery (HRSI) are routinely evaluated during the so-called in-orbit test period, in order to verify if their quality fits the desired features and, if necessary, to obtain the image correction parameters to be used at the ground processing center. Nevertheless, it is often useful to have tools to evaluate image quality also at the final user level. Image quality is defined by some parameters, such as the radiometric resolution and its accuracy, represented by the noise level, and the geometric resolution and sharpness, described by the Modulation Transfer Function (MTF). This paper proposes a procedure to evaluate these image quality parameters; the procedure was implemented in a suitable software and tested on high resolution imagery acquired by the QuickBird, WorldView-1 and Cartosat-1 satellites. PMID:22412312
Testing, Requirements, and Metrics
NASA Technical Reports Server (NTRS)
Rosenberg, Linda; Hyatt, Larry; Hammer, Theodore F.; Huffman, Lenore; Wilson, William
1998-01-01
The criticality of correct, complete, testable requirements is a fundamental tenet of software engineering. Also critical is complete requirements based testing of the final product. Modern tools for managing requirements allow new metrics to be used in support of both of these critical processes. Using these tools, potential problems with the quality of the requirements and the test plan can be identified early in the life cycle. Some of these quality factors include: ambiguous or incomplete requirements, poorly designed requirements databases, excessive or insufficient test cases, and incomplete linkage of tests to requirements. This paper discusses how metrics can be used to evaluate the quality of the requirements and test to avoid problems later. Requirements management and requirements based testing have always been critical in the implementation of high quality software systems. Recently, automated tools have become available to support requirements management. At NASA's Goddard Space Flight Center (GSFC), automated requirements management tools are being used on several large projects. The use of these tools opens the door to innovative uses of metrics in characterizing test plan quality and assessing overall testing risks. In support of these projects, the Software Assurance Technology Center (SATC) is working to develop and apply a metrics program that utilizes the information now available through the application of requirements management tools. Metrics based on this information provides real-time insight into the testing of requirements and these metrics assist the Project Quality Office in its testing oversight role. This paper discusses three facets of the SATC's efforts to evaluate the quality of the requirements and test plan early in the life cycle, thus preventing costly errors and time delays later.
[Software for illustrating a cost-quality balance carried out by clinical laboratory practice].
Nishibori, Masahiro; Asayama, Hitoshi; Kimura, Satoshi; Takagi, Yasushi; Hagihara, Michio; Fujiwara, Mutsunori; Yoneyama, Akiko; Watanabe, Takashi
2010-09-01
We have no proper reference indicating the quality of clinical laboratory practice, which should clearly illustrates that better medical tests require more expenses. Japanese Society of Laboratory Medicine was concerned about recent difficult medical economy and issued a committee report proposing a guideline to evaluate the good laboratory practice. According to the guideline, we developed software that illustrate a cost-quality balance carried out by clinical laboratory practice. We encountered a number of controversial problems, for example, how to measure and weight each quality-related factor, how to calculate costs of a laboratory test and how to consider characteristics of a clinical laboratory. Consequently we finished only prototype software within the given period and the budget. In this paper, software implementation of the guideline and the above-mentioned problems are summarized. Aiming to stimulate these discussions, the operative software will be put on the Society's homepage for trial
A survey of Canadian medical physicists: software quality assurance of in‐house software
Kelly, Diane
2015-01-01
This paper reports on a survey of medical physicists who write and use in‐house written software as part of their professional work. The goal of the survey was to assess the extent of in‐house software usage and the desire or need for related software quality guidelines. The survey contained eight multiple‐choice questions, a ranking question, and seven free text questions. The survey was sent to medical physicists associated with cancer centers across Canada. The respondents to the survey expressed interest in having guidelines to help them in their software‐related work, but also demonstrated extensive skills in the area of testing, safety, and communication. These existing skills form a basis for medical physicists to establish a set of software quality guidelines. PACS number: 87.55.Qr PMID:25679168
A Guide to Software Evaluation.
ERIC Educational Resources Information Center
Leonard, Rex; LeCroy, Barbara
Arguing that software evaluation is crucial to the quality of courseware available in a school, this paper begins by discussing reasons why microcomputers are making such a tremendous impact on education, and notes that, although the quality of software has improved over the years, the challenge for teachers to integrate computing into the…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-02
... Machines (IBM), Software Group Business Unit, Quality Assurance Group, San Jose, California; Notice of... workers of International Business Machines (IBM), Software Group Business Unit, Optim Data Studio Tools QA... February 2, 2011 (76 FR 5832). The subject worker group supplies acceptance testing services, design...
Fostering successful scientific software communities
NASA Astrophysics Data System (ADS)
Bangerth, W.; Heister, T.; Hwang, L.; Kellogg, L. H.
2016-12-01
Developing sustainable open source software packages for the sciences appears at first to be primarily a technical challenge: How can one create stable and robust algorithms, appropriate software designs, sufficient documentation, quality assurance strategies such as continuous integration and test suites, or backward compatibility approaches that yield high-quality software usable not only by the authors, but also the broader community of scientists? However, our experience from almost two decades of leading the development of the deal.II software library (http://www.dealii.org, a widely-used finite element package) and the ASPECT code (http://aspect.dealii.org, used to simulate convection in the Earth's mantle) has taught us that technical aspects are not the most difficult ones in scientific open source software. Rather, it is the social challenge of building and maintaining a community of users and developers interested in answering questions on user forums, contributing code, and jointly finding solutions to common technical and non-technical challenges. These problems are posed in an environment where project leaders typically have no resources to reward the majority of contributors, where very few people are specifically paid for the work they do on the project, and with frequent turnover of contributors as project members rotate into and out of jobs. In particular, much software work is done by graduate students who may become fluent enough in a software only a year or two before they leave academia. We will discuss strategies we have found do and do not work in maintaining and growing communities around the scientific software projects we lead. Specifically, we will discuss the management style necessary to keep contributors engaged, ways to give credit where credit is due, and structuring documentation to decrease reliance on forums and thereby allow user communities to grow without straining those who answer questions.
The Assistant for Specifying the Quality Software (ASQS) Operational Concept Document. Volume 1
1990-09-01
Assistant in which the manager supplies system-specific characteristics and needs and the Assistant fills in the software quality concepts and methods. The...member(s) of the Computer Resources Working Group (CRWG) to aid in performing a software quality engineering study. Figure 3.4-1 outlines the...need to recovery from faults more likely than need _o provide alternative functions or interfaces), and more on Autcncmy - 27 - that Modularity
Automatic structured grid generation using Gridgen (some restrictions apply)
NASA Technical Reports Server (NTRS)
Chawner, John R.; Steinbrenner, John P.
1995-01-01
The authors have noticed in the recent grid generation literature an emphasis on the automation of structured grid generation. The motivation behind such work is clear; grid generation is easily the most despised task in the grid-analyze-visualize triad of computational analysis (CA). However, because grid generation is closely coupled to both the design and analysis software and because quantitative measures of grid quality are lacking, 'push button' grid generation usually results in a compromise between speed, control, and quality. Overt emphasis on automation obscures the substantive issues of providing users with flexible tools for generating and modifying high quality grids in a design environment. In support of this paper's tongue-in-cheek title, many features of the Gridgen software are described. Gridgen is by no stretch of the imagination an automatic grid generator. Despite this fact, the code does utilize many automation techniques that permit interesting regenerative features.
Software Fault Tolerance: A Tutorial
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo
2000-01-01
Because of our present inability to produce error-free software, software fault tolerance is and will continue to be an important consideration in software systems. The root cause of software design errors is the complexity of the systems. Compounding the problems in building correct software is the difficulty in assessing the correctness of software for highly complex systems. After a brief overview of the software development processes, we note how hard-to-detect design faults are likely to be introduced during development and how software faults tend to be state-dependent and activated by particular input sequences. Although component reliability is an important quality measure for system level analysis, software reliability is hard to characterize and the use of post-verification reliability estimates remains a controversial issue. For some applications software safety is more important than reliability, and fault tolerance techniques used in those applications are aimed at preventing catastrophes. Single version software fault tolerance techniques discussed include system structuring and closure, atomic actions, inline fault detection, exception handling, and others. Multiversion techniques are based on the assumption that software built differently should fail differently and thus, if one of the redundant versions fails, it is expected that at least one of the other versions will provide an acceptable output. Recovery blocks, N-version programming, and other multiversion techniques are reviewed.
Carreer, William J.; Flight, Robert M.; Moseley, Hunter N. B.
2013-01-01
New metabolomics applications of ultra-high resolution and accuracy mass spectrometry can provide thousands of detectable isotopologues, with the number of potentially detectable isotopologues increasing exponentially with the number of stable isotopes used in newer isotope tracing methods like stable isotope-resolved metabolomics (SIRM) experiments. This huge increase in usable data requires software capable of correcting the large number of isotopologue peaks resulting from SIRM experiments in a timely manner. We describe the design of a new algorithm and software system capable of handling these high volumes of data, while including quality control methods for maintaining data quality. We validate this new algorithm against a previous single isotope correction algorithm in a two-step cross-validation. Next, we demonstrate the algorithm and correct for the effects of natural abundance for both 13C and 15N isotopes on a set of raw isotopologue intensities of UDP-N-acetyl-D-glucosamine derived from a 13C/15N-tracing experiment. Finally, we demonstrate the algorithm on a full omics-level dataset. PMID:24404440
Automated Translation of Safety Critical Application Software Specifications into PLC Ladder Logic
NASA Technical Reports Server (NTRS)
Leucht, Kurt W.; Semmel, Glenn S.
2008-01-01
The numerous benefits of automatic application code generation are widely accepted within the software engineering community. A few of these benefits include raising the abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at the NASA Kennedy Space Center (KSC) recognized the need for PLC code generation while developing their new ground checkout and launch processing system. They developed a process and a prototype software tool that automatically translates a high-level representation or specification of safety critical application software into ladder logic that executes on a PLC. This process and tool are expected to increase the reliability of the PLC code over that which is written manually, and may even lower life-cycle costs and shorten the development schedule of the new control system at KSC. This paper examines the problem domain and discusses the process and software tool that were prototyped by the KSC software engineers.
Development of Cell Analysis Software for Cultivated Corneal Endothelial Cells.
Okumura, Naoki; Ishida, Naoya; Kakutani, Kazuya; Hongo, Akane; Hiwa, Satoru; Hiroyasu, Tomoyuki; Koizumi, Noriko
2017-11-01
To develop analysis software for cultured human corneal endothelial cells (HCECs). Software was designed to recognize cell borders and to provide parameters such as cell density, coefficient of variation, and polygonality of cultured HCECs based on phase contrast images. Cultured HCECs with high or low cell density were incubated with Ca-free and Mg-free phosphate-buffered saline for 10 minutes to reveal the cell borders and were then analyzed with software (n = 50). Phase contrast images showed that cell borders were not distinctly outlined, but these borders became more distinctly outlined after phosphate-buffered saline treatment and were recognized by cell analysis software. The cell density value provided by software was similar to that obtained using manual cell counting by an experienced researcher. Morphometric parameters, such as the coefficient of variation and polygonality, were also produced by software, and these values were significantly correlated with cell density (Pearson correlation coefficients -0.62 and 0.63, respectively). The software described here provides morphometric information from phase contrast images, and it enables subjective and noninvasive quality assessment for tissue engineering therapy of the corneal endothelium.
NASA Technical Reports Server (NTRS)
Hops, J. M.; Sherif, J. S.
1994-01-01
A great deal of effort is now being devoted to the study, analysis, prediction, and minimization of software maintenance expected cost, long before software is delivered to users or customers. It has been estimated that, on the average, the effort spent on software maintenance is as costly as the effort spent on all other software costs. Software design methods should be the starting point to aid in alleviating the problems of software maintenance complexity and high costs. Two aspects of maintenance deserve attention: (1) protocols for locating and rectifying defects, and for ensuring that noe new defects are introduced in the development phase of the software process; and (2) protocols for modification, enhancement, and upgrading. This article focuses primarily on the second aspect, the development of protocols to help increase the quality and reduce the costs associated with modifications, enhancements, and upgrades of existing software. This study developed parsimonious models and a relative complexity metric for complexity measurement of software that were used to rank the modules in the system relative to one another. Some success was achieved in using the models and the relative metric to identify maintenance-prone modules.
NASA Technical Reports Server (NTRS)
Kapoor, Manju M.; Mehta, Manju
2010-01-01
The goal of this paper is to emphasize the importance of developing complete and unambiguous requirements early in the project cycle (prior to Preliminary Design Phase). Having a complete set of requirements early in the project cycle allows sufficient time to generate a traceability matrix. Requirements traceability and analysis are the key elements in improving verification and validation process, and thus overall software quality. Traceability can be most beneficial when the system changes. If changes are made to high-level requirements it implies that low-level requirements need to be modified. Traceability ensures that requirements are appropriately and efficiently verified at various levels whereas analysis ensures that a rightly interpreted set of requirements is produced.
ERIC Educational Resources Information Center
Chen, Yixing
2013-01-01
The objective of this study was to develop a "Virtual Design Studio (VDS)": a software platform for integrated, coordinated and optimized design of green building systems with low energy consumption, high indoor environmental quality (IEQ), and high level of sustainability. The VDS is intended to assist collaborating architects,…
Virginio, Luiz A; Ricarte, Ivan Luiz Marques
2015-01-01
Although Electronic Health Records (EHR) can offer benefits to the health care process, there is a growing body of evidence that these systems can also incur risks to patient safety when developed or used improperly. This work is a literature review to identify these risks from a software quality perspective. Therefore, the risks were classified based on the ISO/IEC 25010 software quality model. The risks identified were related mainly to the characteristics of "functional suitability" (i.e., software bugs) and "usability" (i.e., interface prone to user error). This work elucidates the fact that EHR quality problems can adversely affect patient safety, resulting in errors such as incorrect patient identification, incorrect calculation of medication dosages, and lack of access to patient data. Therefore, the risks presented here provide the basis for developers and EHR regulating bodies to pay attention to the quality aspects of these systems that can result in patient harm.
Revealing the ISO/IEC 9126-1 Clique Tree for COTS Software Evaluation
NASA Technical Reports Server (NTRS)
Morris, A. Terry
2007-01-01
Previous research has shown that acyclic dependency models, if they exist, can be extracted from software quality standards and that these models can be used to assess software safety and product quality. In the case of commercial off-the-shelf (COTS) software, the extracted dependency model can be used in a probabilistic Bayesian network context for COTS software evaluation. Furthermore, while experts typically employ Bayesian networks to encode domain knowledge, secondary structures (clique trees) from Bayesian network graphs can be used to determine the probabilistic distribution of any software variable (attribute) using any clique that contains that variable. Secondary structures, therefore, provide insight into the fundamental nature of graphical networks. This paper will apply secondary structure calculations to reveal the clique tree of the acyclic dependency model extracted from the ISO/IEC 9126-1 software quality standard. Suggestions will be provided to describe how the clique tree may be exploited to aid efficient transformation of an evaluation model.
A method for tailoring the information content of a software process model
NASA Technical Reports Server (NTRS)
Perkins, Sharon; Arend, Mark B.
1990-01-01
The framework is defined for a general method for selecting a necessary and sufficient subset of a general software life cycle's information products, to support new software development process. Procedures for characterizing problem domains in general and mapping to a tailored set of life cycle processes and products is presented. An overview of the method is shown using the following steps: (1) During the problem concept definition phase, perform standardized interviews and dialogs between developer and user, and between user and customer; (2) Generate a quality needs profile of the software to be developed, based on information gathered in step 1; (3) Translate the quality needs profile into a profile of quality criteria that must be met by the software to satisfy the quality needs; (4) Map the quality criteria to set of accepted processes and products for achieving each criterion; (5) Select the information products which match or support the accepted processes and product of step 4; and (6) Select the design methodology which produces the information products selected in step 5.
A method for tailoring the information content of a software process model
NASA Technical Reports Server (NTRS)
Perkins, Sharon; Arend, Mark B.
1990-01-01
The framework is defined for a general method for selecting a necessary and sufficient subset of a general software life cycle's information products, to support new software development process. Procedures for characterizing problem domains in general and mapping to a tailored set of life cycle processes and products is presented. An overview of the method is shown using the following steps: (1) During the problem concept definition phase, perform standardized interviews and dialogs between developer and user, and between user and customer; (2) Generate a quality needs profile of the software to be developed, based on information gathered in step 1; (3) Translate the quality needs profile into a profile of quality criteria that must be met by the software to satisfy the quality needs; (4) Map the quality criteria to a set of accepted processes and products for achieving each criterion; (5) select the information products which match or support the accepted processes and product of step 4; and (6) Select the design methodology which produces the information products selected in step 5.
NASA Astrophysics Data System (ADS)
Gan, M. A.; Ustinov, S. I.; Starkov, A. A.
1993-08-01
A theory, methods, and software are developed for the automated calculation of the retouching profile in order to compensate axisymmetric and nonaxisymmetric aberrations that are caused by errors in the fabrication of high-resolution optical systems. The retouching profile is calculated on the basis of interferograms recorded within the field of view of the objective. The software makes it possible to estimate the effectiveness of the retouching on the basis of optophysical image-quality criteria.
Design and implementation of a cloud based lithography illumination pupil processing application
NASA Astrophysics Data System (ADS)
Zhang, Youbao; Ma, Xinghua; Zhu, Jing; Zhang, Fang; Huang, Huijie
2017-02-01
Pupil parameters are important parameters to evaluate the quality of lithography illumination system. In this paper, a cloud based full-featured pupil processing application is implemented. A web browser is used for the UI (User Interface), the websocket protocol and JSON format are used for the communication between the client and the server, and the computing part is implemented in the server side, where the application integrated a variety of high quality professional libraries, such as image processing libraries libvips and ImageMagic, automatic reporting system latex, etc., to support the program. The cloud based framework takes advantage of server's superior computing power and rich software collections, and the program could run anywhere there is a modern browser due to its web UI design. Compared to the traditional way of software operation model: purchased, licensed, shipped, downloaded, installed, maintained, and upgraded, the new cloud based approach, which is no installation, easy to use and maintenance, opens up a new way. Cloud based application probably is the future of the software development.
Developing medical device software in compliance with regulations.
Zema, M; Rosati, S; Gioia, V; Knaflitz, M; Balestra, G
2015-08-01
In the last decade, the use of information technology (IT) in healthcare has taken a growing role. In fact, the adoption of an increasing number of computer tools has led to several benefits related to the process of patient care and allowed easier access to social and health care resources. At the same time this trend gave rise to new challenges related to the implementation of these new technologies. Software used in healthcare can be classified as medical devices depending on the way they are used and on their functional characteristics. If they are classified as medical devices they must satisfy specific regulations. The aim of this work is to present a software development framework that can allow the production of safe and high quality medical device software and to highlight the correspondence between each software development phase and the appropriate standard and/or regulation.
Architecture of a Framework for Providing Information Services for Public Transport
García, Carmelo R.; Pérez, Ricardo; Lorenzo, Álvaro; Quesada-Arencibia, Alexis; Alayón, Francisco; Padrón, Gabino
2012-01-01
This paper presents OnRoute, a framework for developing and running ubiquitous software that provides information services to passengers of public transportation, including payment systems and on-route guidance services. To achieve a high level of interoperability, accessibility and context awareness, OnRoute uses the ubiquitous computing paradigm. To guarantee the quality of the software produced, the reliable software principles used in critical contexts, such as automotive systems, are also considered by the framework. The main components of its architecture (run-time, system services, software components and development discipline) and how they are deployed in the transportation network (stations and vehicles) are described in this paper. Finally, to illustrate the use of OnRoute, the development of a guidance service for travellers is explained. PMID:22778585
Kralj, Damir; Kern, Josipa; Tonkovic, Stanko; Koncar, Miroslav
2015-09-09
Family medicine practices (FMPs) make the basis for the Croatian health care system. Use of electronic health record (EHR) software is mandatory and it plays an important role in running these practices, but important functional features still remain uneven and largely left to the will of the software developers. The objective of this study was to develop a novel and comprehensive model for functional evaluation of the EHR software in FMPs, based on current world standards, models and projects, as well as on actual user satisfaction and requirements. Based on previous theoretical and experimental research in this area, we made the initial framework model consisting of six basic categories as a base for online survey questionnaire. Family doctors assessed perceived software quality by using a five-point Likert-type scale. Using exploratory factor analysis and appropriate statistical methods over the collected data, the final optimal structure of the novel model was formed. Special attention was focused on the validity and quality of the novel model. The online survey collected a total of 384 cases. The obtained results indicate both the quality of the assessed software and the quality in use of the novel model. The intense ergonomic orientation of the novel measurement model was particularly emphasised. The resulting novel model is multiple validated, comprehensive and universal. It could be used to assess the user-perceived quality of almost all forms of the ambulatory EHR software and therefore useful to all stakeholders in this area of the health care informatisation.
NASA's Approach to Software Assurance
NASA Technical Reports Server (NTRS)
Wetherholt, Martha
2015-01-01
NASA defines software assurance as: the planned and systematic set of activities that ensure conformance of software life cycle processes and products to requirements, standards, and procedures via quality, safety, reliability, and independent verification and validation. NASA's implementation of this approach to the quality, safety, reliability, security and verification and validation of software is brought together in one discipline, software assurance. Organizationally, NASA has software assurance at each NASA center, a Software Assurance Manager at NASA Headquarters, a Software Assurance Technical Fellow (currently the same person as the SA Manager), and an Independent Verification and Validation Organization with its own facility. An umbrella risk mitigation strategy for safety and mission success assurance of NASA's software, software assurance covers a wide area and is better structured to address the dynamic changes in how software is developed, used, and managed, as well as it's increasingly complex functionality. Being flexible, risk based, and prepared for challenges in software at NASA is essential, especially as much of our software is unique for each mission.
Measuring health care process quality with software quality measures.
Yildiz, Ozkan; Demirörs, Onur
2012-01-01
Existing quality models focus on some specific diseases, clinics or clinical areas. Although they contain structure, process, or output type measures, there is no model which measures quality of health care processes comprehensively. In addition, due to the not measured overall process quality, hospitals cannot compare quality of processes internally and externally. To bring a solution to above problems, a new model is developed from software quality measures. We have adopted the ISO/IEC 9126 software quality standard for health care processes. Then, JCIAS (Joint Commission International Accreditation Standards for Hospitals) measurable elements were added to model scope for unifying functional requirements. Assessment (diagnosing) process measurement results are provided in this paper. After the application, it was concluded that the model determines weak and strong aspects of the processes, gives a more detailed picture for the process quality, and provides quantifiable information to hospitals to compare their processes with multiple organizations.
Certification of production-quality gLite Job Management components
NASA Astrophysics Data System (ADS)
Andreetto, P.; Bertocco, S.; Capannini, F.; Cecchi, M.; Dorigo, A.; Frizziero, E.; Giacomini, F.; Gianelle, A.; Mezzadri, M.; Molinari, E.; Monforte, S.; Prelz, F.; Rebatto, D.; Sgaravatto, M.; Zangrando, L.
2011-12-01
With the advent of the recent European Union (EU) funded projects aimed at achieving an open, coordinated and proactive collaboration among the European communities that provide distributed computing services, more strict requirements and quality standards will be asked to middleware providers. Such a highly competitive and dynamic environment, organized to comply a business-oriented model, has already started pursuing quality criteria, thus requiring to formally define rigorous procedures, interfaces and roles for each step of the software life-cycle. This will ensure quality-certified releases and updates of the Grid middleware. In the European Middleware Initiative (EMI), the release management for one or more components will be organized into Product Team (PT) units, fully responsible for delivering production ready, quality-certified software and for coordinating each other to contribute to the EMI release as a whole. This paper presents the certification process, with respect to integration, installation, configuration and testing, adopted at INFN by the Product Team responsible for the gLite Web-Service based Computing Element (CREAM CE) and for the Workload Management System (WMS). The used resources, the testbeds layout, the integration and deployment methods, the certification steps to provide feedback to developers and to grant quality results are described.
Software Quality Assurance and Controls Standard
2010-04-27
Software Quality Assurance d C t l St d dan on ro s an ar Sue Carroll Principal Software Quality Analyst, SAS John Wal z VP Technology and...for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that...Cycle (SLC) process? • What is in a SQA Process? • Where are SQA Controls? • What is the SQA standards history? Wh t i h i i SQA?• a s c ang ng n
NASA Astrophysics Data System (ADS)
Mills, M. W.; Hutchinson, Matthew J.
2005-05-01
A variety of consumer applications, eg cellphone camera lenses, optical storage devices, digital cameras, etc, are driving the demand for small, high aspheric departure rotationally-symmetric moulded optics, manufactured both in polymer and glass materials. The mould tools for such components are manufactured by ultra-high precision techniques such as single point diamond turning and ultra-precision grinding, and must be accurate to <1/10μm levels for form, and exhibit nanometric surface finish quality. The aspheric forms of such components' optical surfaces exhibit high departure from best-fit sphere towards their outer edge, which renders this outer region especially critical for optical performance. The high slope of these components at the clear aperture has caused some restrictions on the use of profilometry in the measurement of form across their full diameter. Taylor Hobson designs and manufactures a range of ultra-precision profilometers for use in such industries as aspheric optics fabrication. In order to address the issues described, a new measurement system, Taylor Hobson Form Talysurf PGI 1250, has been developed, which contains new Aspheric Data Fusion Software, as well as Asphero-Diffractive Analysis Software, allowing the entire diametric profile to be analysed to the desired level of accuracy. This development removes the previous limitation of maximum slope for this type of measurement, thus enabling better quality control of high slope, high aspheric departure optics. Measurement data from the Form Talysurf PGI 1250 can be fed back directly to the machine tool, in order to optimize the form of the optical mould.
NASA Astrophysics Data System (ADS)
Mills, M. W.; Hutchinson, Matthew J.
2005-05-01
A variety of consumer applications, eg cellphone camera lenses, optical storage devices, digital cameras, etc, are driving the demand for small, high aspheric departure rotationally-symmetric moulded optics, manufactured both in polymer and glass materials. The mould tools for such components are manufactured by ultra-high precision techniques such as single point diamond turning and ultra-precision grinding, and must be accurate to <1/10μm levels for form, and exhibit nanometric surface finish quality. The aspheric forms of such components" optical surfaces exhibit high departure from best-fit sphere towards their outer edge, which renders this outer region especially critical for optical performance. The high slope of these components at the clear aperture has caused some restrictions on the use of profilometry in the measurement of form across their full diameter. Taylor Hobson designs and manufactures a range of ultra-precision profilometers for use in such industries as aspheric optics fabrication. In order to address the issues described, a new measurement system, Taylor Hobson Form Talysurf PGI 1250, has been developed, which contains new Aspheric Data Fusion Software, as well as Asphero-Diffractive Analysis Software, allowing the entire diametric profile to be analysed to the desired level of accuracy. This development removes the previous limitation of maximum slope for this type of measurement, thus enabling better quality control of high slope, high aspheric departure optics. Measurement data from the Form Talysurf PGI 1250 can be fed back directly to the machine tool, in order to optimize the form of the optical mould.
Simple solution to the medical instrumentation software problem
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Leif, Suzanne B.; Leif, Stephanie H.; Bingue, E.
1995-04-01
Medical devices now include a substantial software component, which is both difficult and expensive to produce and maintain. Medical software must be developed according to `Good Manufacturing Practices', GMP. Good Manufacturing Practices as specified by the FDA and ISO requires the definition and compliance to a software processes which ensures quality products by specifying a detailed method of software construction. The software process should be based on accepted standards. US Department of Defense software standards and technology can both facilitate the development and improve the quality of medical systems. We describe the advantages of employing Mil-Std-498, Software Development and Documentation, and the Ada programming language. Ada provides the very broad range of functionalities, from embedded real-time to management information systems required by many medical devices. It also includes advanced facilities for object oriented programming and software engineering.
Projecting manpower to attain quality
NASA Technical Reports Server (NTRS)
Rone, K. Y.
1983-01-01
The resulting model is useful as a projection tool but must be validated in order to be used as an on-going software cost engineering tool. A procedure is developed to facilitate the tracking of model projections and actual data to allow the model to be tuned. Finally, since the model must be used in an environment of overlapping development activities on a progression of software elements in development and maintenance, a manpower allocation model is developed for use in a steady state development/maintenance environment. In these days of soaring software costs it becomes increasingly important to properly manage a software development project. One element of the management task is the projection and tracking of manpower required to perform the task. In addition, since the total cost of the task is directly related to the initial quality built into the software, it becomes a necessity to project the development manpower in a way to attain that quality. An approach to projecting and tracking manpower with quality in mind is described.
A quality-refinement process for medical imaging applications.
Neuhaus, J; Maleike, D; Nolden, M; Kenngott, H-G; Meinzer, H-P; Wolf, I
2009-01-01
To introduce and evaluate a process for refinement of software quality that is suitable to research groups. In order to avoid constraining researchers too much, the quality improvement process has to be designed carefully. The scope of this paper is to present and evaluate a process to advance quality aspects of existing research prototypes in order to make them ready for initial clinical studies. The proposed process is tailored for research environments and therefore more lightweight than traditional quality management processes. Focus on quality criteria that are important at the given stage of the software life cycle. Usage of tools that automate aspects of the process is emphasized. To evaluate the additional effort that comes along with the process, it was exemplarily applied for eight prototypical software modules for medical image processing. The introduced process has been applied to improve the quality of all prototypes so that they could be successfully used in clinical studies. The quality refinement yielded an average of 13 person days of additional effort per project. Overall, 107 bugs were found and resolved by applying the process. Careful selection of quality criteria and the usage of automated process tools lead to a lightweight quality refinement process suitable for scientific research groups that can be applied to ensure a successful transfer of technical software prototypes into clinical research workflows.
NASA Astrophysics Data System (ADS)
Drachova-Strang, Svetlana V.
As computing becomes ubiquitous, software correctness has a fundamental role in ensuring the safety and security of the systems we build. To design and develop software correctly according to their formal contracts, CS students, the future software practitioners, need to learn a critical set of skills that are necessary and sufficient for reasoning about software correctness. This dissertation presents a systematic approach to both introducing these reasoning skills into the curriculum, and assessing how well the students have learned them. Specifically, it introduces a comprehensive Reasoning Concept Inventory (RCI) that captures the fine details of basic reasoning skills that are ideally learned across the undergraduate curriculum to reason about software correctness, to develop high quality software, and to understand why software works as specified. The RCI forms the basis for developing learning outcomes that help educators to assess the adequacy of current techniques and pinpoint necessary improvements. This dissertation contains results from experimentation and assessment over the past few years in multiple CS courses. The results show that the finer principles of mathematical reasoning of software correctness can be taught effectively and continuously improved with the help of the RCI using suitable teaching practices, and supporting methods and tools.
SIMULATION TOOL KIT FOR INDOOR AIR QUALITY AND INHALATION EXPOSURE (IAQX) VERSION 1.0 USER'S GUIDE
The User's Guide describes a Microsoft Windows-based indoor air quality (IAQ) simulation software package designed Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short. This software complements and supplements existing IAQ simulation programs and...
Digital radiography: optimization of image quality and dose using multi-frequency software.
Precht, H; Gerke, O; Rosendahl, K; Tingberg, A; Waaler, D
2012-09-01
New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.
Desktop Publishing for Counselors.
ERIC Educational Resources Information Center
Lucking, Robert; Mitchum, Nancy
1990-01-01
Discusses the fundamentals of desktop publishing for counselors, including hardware and software systems and peripherals. Notes by using desktop publishing, counselors can produce their own high-quality documents without the expense of commercial printers. Concludes computers present a way of streamlining the communications of a counseling…
Unisys' experience in software quality and productivity management of an existing system
NASA Technical Reports Server (NTRS)
Munson, John B.
1988-01-01
A summary of Quality Improvement techniques, implementation, and results in the maintenance, management, and modification of large software systems for the Space Shuttle Program's ground-based systems is provided.
Quality and standardization of telecommunication switching system software
NASA Astrophysics Data System (ADS)
Ranko, K.; Hivensaio, J.; Myllykangas, A.
1981-12-01
The purpose of this paper has been to illustrate quality and standardization of switching system software from the authors point of view with the aim of developing standardization in the user environment.
A software framework for developing measurement applications under variable requirements.
Arpaia, Pasquale; Buzio, Marco; Fiscarelli, Lucio; Inglese, Vitaliano
2012-11-01
A framework for easily developing software for measurement and test applications under highly and fast-varying requirements is proposed. The framework allows the software quality, in terms of flexibility, usability, and maintainability, to be maximized. Furthermore, the development effort is reduced and finalized, by relieving the test engineer of development details. The framework can be configured for satisfying a large set of measurement applications in a generic field for an industrial test division, a test laboratory, or a research center. As an experimental case study, the design, the implementation, and the assessment inside the application to a measurement scenario of magnet testing at the European Organization for Nuclear Research is reported.
OpenROCS: a software tool to control robotic observatories
NASA Astrophysics Data System (ADS)
Colomé, Josep; Sanz, Josep; Vilardell, Francesc; Ribas, Ignasi; Gil, Pere
2012-09-01
We present the Open Robotic Observatory Control System (OpenROCS), an open source software platform developed for the robotic control of telescopes. It acts as a software infrastructure that executes all the necessary processes to implement responses to the system events that appear in the routine and non-routine operations associated to data-flow and housekeeping control. The OpenROCS software design and implementation provides a high flexibility to be adapted to different observatory configurations and event-action specifications. It is based on an abstract model that is independent of the specific hardware or software and is highly configurable. Interfaces to the system components are defined in a simple manner to achieve this goal. We give a detailed description of the version 2.0 of this software, based on a modular architecture developed in PHP and XML configuration files, and using standard communication protocols to interface with applications for hardware monitoring and control, environment monitoring, scheduling of tasks, image processing and data quality control. We provide two examples of how it is used as the core element of the control system in two robotic observatories: the Joan Oró Telescope at the Montsec Astronomical Observatory (Catalonia, Spain) and the SuperWASP Qatar Telescope at the Roque de los Muchachos Observatory (Canary Islands, Spain).
Modeling and Grid Generation of Iced Airfoils
NASA Technical Reports Server (NTRS)
Vickerman, Mary B.; Baez, Marivell; Braun, Donald C.; Hackenberg, Anthony W.; Pennline, James A.; Schilling, Herbert W.
2007-01-01
SmaggIce Version 2.0 is a software toolkit for geometric modeling and grid generation for two-dimensional, singleand multi-element, clean and iced airfoils. A previous version of SmaggIce was described in Preparing and Analyzing Iced Airfoils, NASA Tech Briefs, Vol. 28, No. 8 (August 2004), page 32. To recapitulate: Ice shapes make it difficult to generate quality grids around airfoils, yet these grids are essential for predicting ice-induced complex flow. This software efficiently creates high-quality structured grids with tools that are uniquely tailored for various ice shapes. SmaggIce Version 2.0 significantly enhances the previous version primarily by adding the capability to generate grids for multi-element airfoils. This version of the software is an important step in streamlining the aeronautical analysis of ice airfoils using computational fluid dynamics (CFD) tools. The user may prepare the ice shape, define the flow domain, decompose it into blocks, generate grids, modify/divide/merge blocks, and control grid density and smoothness. All these steps may be performed efficiently even for the difficult glaze and rime ice shapes. Providing the means to generate highly controlled grids near rough ice, the software includes the creation of a wrap-around block (called the "viscous sublayer block"), which is a thin, C-type block around the wake line and iced airfoil. For multi-element airfoils, the software makes use of grids that wrap around and fill in the areas between the viscous sub-layer blocks for all elements that make up the airfoil. A scripting feature records the history of interactive steps, which can be edited and replayed later to produce other grids. Using this version of SmaggIce, ice shape handling and grid generation can become a practical engineering process, rather than a laborious research effort.
Massive stereo-based DTM production for Mars on cloud computers
NASA Astrophysics Data System (ADS)
Tao, Y.; Muller, J.-P.; Sidiropoulos, P.; Xiong, Si-Ting; Putri, A. R. D.; Walter, S. H. G.; Veitch-Michaelis, J.; Yershov, V.
2018-05-01
Digital Terrain Model (DTM) creation is essential to improving our understanding of the formation processes of the Martian surface. Although there have been previous demonstrations of open-source or commercial planetary 3D reconstruction software, planetary scientists are still struggling with creating good quality DTMs that meet their science needs, especially when there is a requirement to produce a large number of high quality DTMs using "free" software. In this paper, we describe a new open source system to overcome many of these obstacles by demonstrating results in the context of issues found from experience with several planetary DTM pipelines. We introduce a new fully automated multi-resolution DTM processing chain for NASA Mars Reconnaissance Orbiter (MRO) Context Camera (CTX) and High Resolution Imaging Science Experiment (HiRISE) stereo processing, called the Co-registration Ames Stereo Pipeline (ASP) Gotcha Optimised (CASP-GO), based on the open source NASA ASP. CASP-GO employs tie-point based multi-resolution image co-registration, and Gotcha sub-pixel refinement and densification. CASP-GO pipeline is used to produce planet-wide CTX and HiRISE DTMs that guarantee global geo-referencing compliance with respect to High Resolution Stereo Colour imaging (HRSC), and thence to the Mars Orbiter Laser Altimeter (MOLA); providing refined stereo matching completeness and accuracy. All software and good quality products introduced in this paper are being made open-source to the planetary science community through collaboration with NASA Ames, United States Geological Survey (USGS) and the Jet Propulsion Laboratory (JPL), Advanced Multi-Mission Operations System (AMMOS) Planetary Data System (PDS) Pipeline Service (APPS-PDS4), as well as browseable and visualisable through the iMars web based Geographic Information System (webGIS) system.
A Strategy for Improved System Assurance
2007-06-20
Quality (Measurements Life Cycle Safety, Security & Others) ISO /IEC 12207 * Software Life Cycle Processes ISO 9001 Quality Management System...14598 Software Product Evaluation Related ISO /IEC 90003 Guidelines for the Application of ISO 9001:2000 to Computer Software IEEE 12207 Industry...Implementation of International Standard ISO /IEC 12207 IEEE 1220 Standard for Application and Management of the System Engineering Process Use in
Proceedings of Tenth Annual Software Engineering Workshop
NASA Technical Reports Server (NTRS)
1985-01-01
Papers are presented on the following topics: measurement of software technology, recent studies of the Software Engineering Lab, software management tools, expert systems, error seeding as a program validation technique, software quality assurance, software engineering environments (including knowledge-based environments), the Distributed Computing Design System, and various Ada experiments.
MrEnt: an editor for publication-quality phylogenetic tree illustrations.
Zuccon, Alessandro; Zuccon, Dario
2014-09-01
We developed MrEnt, a Windows-based, user-friendly software that allows the production of complex, high-resolution, publication-quality phylogenetic trees in few steps, directly from the analysis output. The program recognizes the standard Nexus tree format and the annotated tree files produced by BEAST and MrBayes. MrEnt combines in a single software a large suite of tree manipulation functions (e.g. handling of multiple trees, tree rotation, character mapping, node collapsing, compression of large clades, handling of time scale and error bars for chronograms) with drawing tools typical of standard graphic editors, including handling of graphic elements and images. The tree illustration can be printed or exported in several standard formats suitable for journal publication, PowerPoint presentation or Web publication. © 2014 John Wiley & Sons Ltd.
Connecting Research and Practice: An Experience Report on Research Infusion with SAVE
NASA Technical Reports Server (NTRS)
Lindvall, Mikael; Stratton, William C.; Sibol, Deane E.; Ackermann, Christopher; Reid, W. Mark; Ganesan, Dharmalingam; McComas, David; Bartholomew, Maureen; Godfrey, Sally
2009-01-01
NASA systems need to be highly dependable to avoid catastrophic mission failures. This calls for rigorous engineering processes including meticulous validation and verification. However, NASA systems are often highly distributed and overwhelmingly complex, making the software portion of these systems challenging to understand, maintain, change, reuse, and test. NASA's systems are long-lived and the software maintenance process typically constitutes 60-80% of the total cost of the entire lifecycle. Thus, in addition to the technical challenges of ensuring high life-time quality of NASA's systems, the post-development phase also presents a significant financial burden. Some of NASA's software-related challenges could potentially be addressed by some of the many powerful technologies that are being developed in software research laboratories. Many of these research technologies seek to facilitate maintenance and evolution by for example architecting, designing and modeling for quality, flexibility, and reuse. Other technologies attempt to detect and remove defects and other quality issues by various forms of automated defect detection, architecture analysis, and various forms of sophisticated simulation and testing. However promising, most such research technologies nevertheless do not make the transition from the research lab to the software lab. One reason the transition from research to practice seldom occurs is that research infusion and technology transfer is difficult. For example, factors related to the technology are sometimes overshadowed by other types of factors such as reluctance to change and therefore prohibits the technology from sticking. Successful infusion might also take very long time. One famous study showed that the discrepancy between the conception of the idea and its practical use was 18 years plus or minus three. Nevertheless, infusing new technology is possible. We have found that it takes special circumstances for such research infusion to succeed: 1) there must be evidence that the technology works in the practitioner's particular domain, 2) there must be a potential for great improvements and enhanced competitive edge for the practitioner, 3) the practitioner has to have strong individual curiosity and continuous interest in trying out new technologies, 4) the practitioner has to have support on multiple levels (i.e. from the researchers, from management, from sponsors etc), and 5) to remain infused, the new technology has to be integrated into the practitioner's processes so that it becomes a natural part of the daily work. NASA IV&V's Research Infusion initiative sponsored by NASA's Office of Safety & Mission Assurance (OSMA) through the Software Assurance Research Program (SARP), strives to overcome some of the problems related to research infusion.
Peterfreund, Robert A; Driscoll, William D; Walsh, John L; Subramanian, Aparna; Anupama, Shaji; Weaver, Melissa; Morris, Theresa; Arnholz, Sarah; Zheng, Hui; Pierce, Eric T; Spring, Stephen F
2011-05-01
Efforts to assure high-quality, safe, clinical care depend upon capturing information about near-miss and adverse outcome events. Inconsistent or unreliable information capture, especially for infrequent events, compromises attempts to analyze events in quantitative terms, understand their implications, and assess corrective efforts. To enhance reporting, we developed a secure, electronic, mandatory system for reporting quality assurance data linked to our electronic anesthesia record. We used the capabilities of our anesthesia information management system (AIMS) in conjunction with internally developed, secure, intranet-based, Web application software. The application is implemented with a backend allowing robust data storage, retrieval, data analysis, and reporting capabilities. We customized a feature within the AIMS software to create a hard stop in the documentation workflow before the end of anesthesia care time stamp for every case. The software forces the anesthesia provider to access the separate quality assurance data collection program, which provides a checklist for targeted clinical events and a free text option. After completing the event collection program, the software automatically returns the clinician to the AIMS to finalize the anesthesia record. The number of events captured by the departmental quality assurance office increased by 92% (95% confidence interval [CI] 60.4%-130%) after system implementation. The major contributor to this increase was the new electronic system. This increase has been sustained over the initial 12 full months after implementation. Under our reporting criteria, the overall rate of clinical events reported by any method was 471 events out of 55,382 cases or 0.85% (95% CI 0.78% to 0.93%). The new system collected 67% of these events (95% confidence interval 63%-71%). We demonstrate the implementation in an academic anesthesia department of a secure clinical event reporting system linked to an AIMS. The system enforces entry of quality assurance information (either no clinical event or notification of a clinical event). System implementation resulted in capturing nearly twice the number of events at a relatively steady case load. © 2011 International Anesthesia Research Society
TMT approach to observatory software development process
NASA Astrophysics Data System (ADS)
Buur, Hanne; Subramaniam, Annapurni; Gillies, Kim; Dumas, Christophe; Bhatia, Ravinder
2016-07-01
The purpose of the Observatory Software System (OSW) is to integrate all software and hardware components of the Thirty Meter Telescope (TMT) to enable observations and data capture; thus it is a complex software system that is defined by four principal software subsystems: Common Software (CSW), Executive Software (ESW), Data Management System (DMS) and Science Operations Support System (SOSS), all of which have interdependencies with the observatory control systems and data acquisition systems. Therefore, the software development process and plan must consider dependencies to other subsystems, manage architecture, interfaces and design, manage software scope and complexity, and standardize and optimize use of resources and tools. Additionally, the TMT Observatory Software will largely be developed in India through TMT's workshare relationship with the India TMT Coordination Centre (ITCC) and use of Indian software industry vendors, which adds complexity and challenges to the software development process, communication and coordination of activities and priorities as well as measuring performance and managing quality and risk. The software project management challenge for the TMT OSW is thus a multi-faceted technical, managerial, communications and interpersonal relations challenge. The approach TMT is using to manage this multifaceted challenge is a combination of establishing an effective geographically distributed software team (Integrated Product Team) with strong project management and technical leadership provided by the TMT Project Office (PO) and the ITCC partner to manage plans, process, performance, risk and quality, and to facilitate effective communications; establishing an effective cross-functional software management team composed of stakeholders, OSW leadership and ITCC leadership to manage dependencies and software release plans, technical complexities and change to approved interfaces, architecture, design and tool set, and to facilitate effective communications; adopting an agile-based software development process across the observatory to enable frequent software releases to help mitigate subsystem interdependencies; defining concise scope and work packages for each of the OSW subsystems to facilitate effective outsourcing of software deliverables to the ITCC partner, and to enable performance monitoring and risk management. At this stage, the architecture and high-level design of the software system has been established and reviewed. During construction each subsystem will have a final design phase with reviews, followed by implementation and testing. The results of the TMT approach to the Observatory Software development process will only be preliminary at the time of the submittal of this paper, but it is anticipated that the early results will be a favorable indication of progress.
Atropos: specific, sensitive, and speedy trimming of sequencing reads.
Didion, John P; Martin, Marcel; Collins, Francis S
2017-01-01
A key step in the transformation of raw sequencing reads into biological insights is the trimming of adapter sequences and low-quality bases. Read trimming has been shown to increase the quality and reliability while decreasing the computational requirements of downstream analyses. Many read trimming software tools are available; however, no tool simultaneously provides the accuracy, computational efficiency, and feature set required to handle the types and volumes of data generated in modern sequencing-based experiments. Here we introduce Atropos and show that it trims reads with high sensitivity and specificity while maintaining leading-edge speed. Compared to other state-of-the-art read trimming tools, Atropos achieves significant increases in trimming accuracy while remaining competitive in execution times. Furthermore, Atropos maintains high accuracy even when trimming data with elevated rates of sequencing errors. The accuracy, high performance, and broad feature set offered by Atropos makes it an appropriate choice for the pre-processing of Illumina, ABI SOLiD, and other current-generation short-read sequencing datasets. Atropos is open source and free software written in Python (3.3+) and available at https://github.com/jdidion/atropos.
Atropos: specific, sensitive, and speedy trimming of sequencing reads
Collins, Francis S.
2017-01-01
A key step in the transformation of raw sequencing reads into biological insights is the trimming of adapter sequences and low-quality bases. Read trimming has been shown to increase the quality and reliability while decreasing the computational requirements of downstream analyses. Many read trimming software tools are available; however, no tool simultaneously provides the accuracy, computational efficiency, and feature set required to handle the types and volumes of data generated in modern sequencing-based experiments. Here we introduce Atropos and show that it trims reads with high sensitivity and specificity while maintaining leading-edge speed. Compared to other state-of-the-art read trimming tools, Atropos achieves significant increases in trimming accuracy while remaining competitive in execution times. Furthermore, Atropos maintains high accuracy even when trimming data with elevated rates of sequencing errors. The accuracy, high performance, and broad feature set offered by Atropos makes it an appropriate choice for the pre-processing of Illumina, ABI SOLiD, and other current-generation short-read sequencing datasets. Atropos is open source and free software written in Python (3.3+) and available at https://github.com/jdidion/atropos. PMID:28875074
Proceedings of the Seventeenth Annual Software Engineering Workshop
NASA Technical Reports Server (NTRS)
1992-01-01
Proceedings of the Seventeenth Annual Software Engineering Workshop are presented. The software Engineering Laboratory (SEL) is an organization sponsored by NASA/Goddard Space Flight Center and created to investigate the effectiveness of software engineering technologies when applied to the development of applications software. Topics covered include: the Software Engineering Laboratory; process measurement; software reuse; software quality; lessons learned; and is Ada dying.
The Software Industry in the Coffee Triangle of Colombia
NASA Astrophysics Data System (ADS)
Cuesta, Albeiro; Joyanes, Luis; López, Marcelo
The so-called "Coffee Triangle" region is located in the Andean Region, in central Colombia, South America. This Andean Region is composed of the Departments of Caldas, Quindío and Risaralda. The Andean Region has been characterized by the production of coffee as a worldwide industry supported by high Quality and Research standards. These components have become the key bastions to compete in international markets. After the decline of the Coffee industry it is necessary to consider alternatives, supplemented by the success of the Software Industry at the global level. The strengthening of the Software Industry in the Coffee Triangle seeks to establish a productive alternative for regional growth in a visionary way, where knowledge, a fundamental input of the Software Industry, is emerging as one of the greatest assets present in this geographical area - Andean Region - of Colombia.
Usability Prediction & Ranking of SDLC Models Using Fuzzy Hierarchical Usability Model
NASA Astrophysics Data System (ADS)
Gupta, Deepak; Ahlawat, Anil K.; Sagar, Kalpna
2017-06-01
Evaluation of software quality is an important aspect for controlling and managing the software. By such evaluation, improvements in software process can be made. The software quality is significantly dependent on software usability. Many researchers have proposed numbers of usability models. Each model considers a set of usability factors but do not cover all the usability aspects. Practical implementation of these models is still missing, as there is a lack of precise definition of usability. Also, it is very difficult to integrate these models into current software engineering practices. In order to overcome these challenges, this paper aims to define the term `usability' using the proposed hierarchical usability model with its detailed taxonomy. The taxonomy considers generic evaluation criteria for identifying the quality components, which brings together factors, attributes and characteristics defined in various HCI and software models. For the first time, the usability model is also implemented to predict more accurate usability values. The proposed system is named as fuzzy hierarchical usability model that can be easily integrated into the current software engineering practices. In order to validate the work, a dataset of six software development life cycle models is created and employed. These models are ranked according to their predicted usability values. This research also focuses on the detailed comparison of proposed model with the existing usability models.
Spectrum analysis on quality requirements consideration in software design documents.
Kaiya, Haruhiko; Umemura, Masahiro; Ogata, Shinpei; Kaijiri, Kenji
2013-12-01
Software quality requirements defined in the requirements analysis stage should be implemented in the final products, such as source codes and system deployment. To guarantee this meta-requirement, quality requirements should be considered in the intermediate stages, such as the design stage or the architectural definition stage. We propose a novel method for checking whether quality requirements are considered in the design stage. In this method, a technique called "spectrum analysis for quality requirements" is applied not only to requirements specifications but also to design documents. The technique enables us to derive the spectrum of a document, and quality requirements considerations in the document are numerically represented in the spectrum. We can thus objectively identify whether the considerations of quality requirements in a requirements document are adapted to its design document. To validate the method, we applied it to commercial software systems with the help of a supporting tool, and we confirmed that the method worked well.
Clos, Lawrence J; Jofre, M Fransisca; Ellinger, James J; Westler, William M; Markley, John L
2013-06-01
To facilitate the high-throughput acquisition of nuclear magnetic resonance (NMR) experimental data on large sets of samples, we have developed a simple and straightforward automated methodology that capitalizes on recent advances in Bruker BioSpin NMR spectrometer hardware and software. Given the daunting challenge for non-NMR experts to collect quality spectra, our goal was to increase user accessibility, provide customized functionality, and improve the consistency and reliability of resultant data. This methodology, NMRbot, is encoded in a set of scripts written in the Python programming language accessible within the Bruker BioSpin TopSpin ™ software. NMRbot improves automated data acquisition and offers novel tools for use in optimizing experimental parameters on the fly. This automated procedure has been successfully implemented for investigations in metabolomics, small-molecule library profiling, and protein-ligand titrations on four Bruker BioSpin NMR spectrometers at the National Magnetic Resonance Facility at Madison. The investigators reported benefits from ease of setup, improved spectral quality, convenient customizations, and overall time savings.
Spatiotemporal matrix image formation for programmable ultrasound scanners
NASA Astrophysics Data System (ADS)
Berthon, Beatrice; Morichau-Beauchant, Pierre; Porée, Jonathan; Garofalakis, Anikitos; Tavitian, Bertrand; Tanter, Mickael; Provost, Jean
2018-02-01
As programmable ultrasound scanners become more common in research laboratories, it is increasingly important to develop robust software-based image formation algorithms that can be obtained in a straightforward fashion for different types of probes and sequences with a small risk of error during implementation. In this work, we argue that as the computational power keeps increasing, it is becoming practical to directly implement an approximation to the matrix operator linking reflector point targets to the corresponding radiofrequency signals via thoroughly validated and widely available simulations software. Once such a spatiotemporal forward-problem matrix is constructed, standard and thus highly optimized inversion procedures can be leveraged to achieve very high quality images in real time. Specifically, we show that spatiotemporal matrix image formation produces images of similar or enhanced quality when compared against standard delay-and-sum approaches in phantoms and in vivo, and show that this approach can be used to form images even when using non-conventional probe designs for which adapted image formation algorithms are not readily available.
An Approach for Integrating the Prioritization of Functional and Nonfunctional Requirements
Dabbagh, Mohammad; Lee, Sai Peck
2014-01-01
Due to the budgetary deadlines and time to market constraints, it is essential to prioritize software requirements. The outcome of requirements prioritization is an ordering of requirements which need to be considered first during the software development process. To achieve a high quality software system, both functional and nonfunctional requirements must be taken into consideration during the prioritization process. Although several requirements prioritization methods have been proposed so far, no particular method or approach is presented to consider both functional and nonfunctional requirements during the prioritization stage. In this paper, we propose an approach which aims to integrate the process of prioritizing functional and nonfunctional requirements. The outcome of applying the proposed approach produces two separate prioritized lists of functional and non-functional requirements. The effectiveness of the proposed approach has been evaluated through an empirical experiment aimed at comparing the approach with the two state-of-the-art-based approaches, analytic hierarchy process (AHP) and hybrid assessment method (HAM). Results show that our proposed approach outperforms AHP and HAM in terms of actual time-consumption while preserving the quality of the results obtained by our proposed approach at a high level of agreement in comparison with the results produced by the other two approaches. PMID:24982987
An approach for integrating the prioritization of functional and nonfunctional requirements.
Dabbagh, Mohammad; Lee, Sai Peck
2014-01-01
Due to the budgetary deadlines and time to market constraints, it is essential to prioritize software requirements. The outcome of requirements prioritization is an ordering of requirements which need to be considered first during the software development process. To achieve a high quality software system, both functional and nonfunctional requirements must be taken into consideration during the prioritization process. Although several requirements prioritization methods have been proposed so far, no particular method or approach is presented to consider both functional and nonfunctional requirements during the prioritization stage. In this paper, we propose an approach which aims to integrate the process of prioritizing functional and nonfunctional requirements. The outcome of applying the proposed approach produces two separate prioritized lists of functional and non-functional requirements. The effectiveness of the proposed approach has been evaluated through an empirical experiment aimed at comparing the approach with the two state-of-the-art-based approaches, analytic hierarchy process (AHP) and hybrid assessment method (HAM). Results show that our proposed approach outperforms AHP and HAM in terms of actual time-consumption while preserving the quality of the results obtained by our proposed approach at a high level of agreement in comparison with the results produced by the other two approaches.
Mueller, David S.
2016-06-21
The software program, QRev applies common and consistent computational algorithms combined with automated filtering and quality assessment of the data to improve the quality and efficiency of streamflow measurements and helps ensure that U.S. Geological Survey streamflow measurements are consistent, accurate, and independent of the manufacturer of the instrument used to make the measurement. Software from different manufacturers uses different algorithms for various aspects of the data processing and discharge computation. The algorithms used by QRev to filter data, interpolate data, and compute discharge are documented and compared to the algorithms used in the manufacturers’ software. QRev applies consistent algorithms and creates a data structure that is independent of the data source. QRev saves an extensible markup language (XML) file that can be imported into databases or electronic field notes software. This report is the technical manual for version 2.8 of QRev.
[Quality assurance of the renal applications software].
del Real Núñez, R; Contreras Puertas, P I; Moreno Ortega, E; Mena Bares, L M; Maza Muret, F R; Latre Romero, J M
2007-01-01
The need for quality assurance of all technical aspects of nuclear medicine studies is widely recognised. However, little attention has been paid to the quality assurance of the applications software. Our work reported here aims at verifying the analysis software for processing of renal nuclear medicine studies (renograms). The software tools were used to build a synthetic dynamic model of renal system. The model consists of two phases: perfusion and function. The organs of interest (kidneys, bladder and aortic artery) were simple geometric forms. The uptake of the renal structures was described by mathematic functions. Curves corresponding to normal or pathological conditions were simulated for kidneys, bladder and aortic artery by appropriate selection of parameters. There was no difference between the parameters of the mathematic curves and the quantitative data produced by the renal analysis program. Our test procedure is simple to apply, reliable, reproducible and rapid to verify the renal applications software.
A User’s Guide for the Software Technology Economic Impact Model
1991-10-01
Copy 16 oft22 oples U AD-A248 023 \\\\1\\\\\\i\\~\\1\\1\\\\1\\1\\11\\\\\\l~ IDA DOCUMENT D-971 E Tt USER’S GUIDE FOR THE SOFTWARE TECHNOLOGY ECONOMIC IMPACT MODEL I... studied , and they are released by the President of IDA. Group Reports Group Reports record the findings and results of IDA established working groups and...the senior individuals responsible for the project and others as selected by IDA to ensure their high quality and relevance to the problems studied
Surgical pathology report in the era of desktop publishing.
Pillarisetti, S G
1993-01-01
Since it is believed that "a picture is worth a thousand words," incorporation of computer-generated line art was used as a adjunct to gross description in surgical pathology reporting in selected cases. The lack of an integrated software program was overcome by using commercially available graphic and word processing software. A library of drawings was developed over the last few years. Most time-consuming is the development of templates and the graphic library. With some effort it is possible to integrate graphics of high quality into surgical pathology reports.
Early experiences building a software quality prediction model
NASA Technical Reports Server (NTRS)
Agresti, W. W.; Evanco, W. M.; Smith, M. C.
1990-01-01
Early experiences building a software quality prediction model are discussed. The overall research objective is to establish a capability to project a software system's quality from an analysis of its design. The technical approach is to build multivariate models for estimating reliability and maintainability. Data from 21 Ada subsystems were analyzed to test hypotheses about various design structures leading to failure-prone or unmaintainable systems. Current design variables highlight the interconnectivity and visibility of compilation units. Other model variables provide for the effects of reusability and software changes. Reported results are preliminary because additional project data is being obtained and new hypotheses are being developed and tested. Current multivariate regression models are encouraging, explaining 60 to 80 percent of the variation in error density of the subsystems.
NASA Astrophysics Data System (ADS)
Dwi Susanto, Tony; Ingesti Prasetyo, Anisa; Astuti, Hanim Maria
2018-03-01
At this moment, the need for web as an information media is highly important. Not only confined in the infotainment area, government, and education, but health as well uses the web media as a medium for providing information effectively. BloobIS is a web based application which integrates blood supply and distribution information at the Blood Transfusion Unit. Knowing how easy information is on BloobIS is marked by how convenient the website is used. Up until now, the BloobIS website is nearing completion but testing has not yet been performed to users and is on the testing and development phase in the Development Life Cycle software. Thus, an evaluation namely the quality control software which focuses on the perspective of BloobIs web usability is required. Hallway Usability Testing and ISO 9241:11 are the methods chosen to measure the BloobIS application usability. The expected outputs of the quality control software focusing on the usability evaluation are being able to rectify the usability deficiencies on the BloobIs web and provide recommendations to develop the web as a basic BloobIS web quality upgraed which sets a goal to amplify the satisfaction of web users based on usability factors in ISO 9241:11.
NASA Astrophysics Data System (ADS)
Preradović, D. M.; Mićić, Lj S.; Barz, C.
2017-05-01
Production conditions in today’s world require software support at every stage of production and development of new products, for quality assurance and compliance with ISO standards. In addition to ISO standards such as usual metrics of quality, companies today are focused on other optional standards, such as CMMI (Capability Maturity Model Integrated) or prescribing they own standards. However, while there is intensive progress being made in the PM (project management), there is still a significant number of projects, at the global level, that are failures. These have failed to achieve their goals, within budget or timeframe. This paper focuses on checking the role of software tools through the rate of success in projects implemented in the case of internationally manufactured electrical equipment. The results of this research show the level of contribution of the project management software used to manage and develop new products to improve PM processes and PM functions, and how selection of the software tools affects the quality of PM processes and successfully completed projects.
The ALICE Software Release Validation cluster
NASA Astrophysics Data System (ADS)
Berzano, D.; Krzewicki, M.
2015-12-01
One of the most important steps of software lifecycle is Quality Assurance: this process comprehends both automatic tests and manual reviews, and all of them must pass successfully before the software is approved for production. Some tests, such as source code static analysis, are executed on a single dedicated service: in High Energy Physics, a full simulation and reconstruction chain on a distributed computing environment, backed with a sample “golden” dataset, is also necessary for the quality sign off. The ALICE experiment uses dedicated and virtualized computing infrastructures for the Release Validation in order not to taint the production environment (i.e. CVMFS and the Grid) with non-validated software and validation jobs: the ALICE Release Validation cluster is a disposable virtual cluster appliance based on CernVM and the Virtual Analysis Facility, capable of deploying on demand, and with a single command, a dedicated virtual HTCondor cluster with an automatically scalable number of virtual workers on any cloud supporting the standard EC2 interface. Input and output data are externally stored on EOS, and a dedicated CVMFS service is used to provide the software to be validated. We will show how the Release Validation Cluster deployment and disposal are completely transparent for the Release Manager, who simply triggers the validation from the ALICE build system's web interface. CernVM 3, based entirely on CVMFS, permits to boot any snapshot of the operating system in time: we will show how this allows us to certify each ALICE software release for an exact CernVM snapshot, addressing the problem of Long Term Data Preservation by ensuring a consistent environment for software execution and data reprocessing in the future.
The Use of UML for Software Requirements Expression and Management
NASA Technical Reports Server (NTRS)
Murray, Alex; Clark, Ken
2015-01-01
It is common practice to write English-language "shall" statements to embody detailed software requirements in aerospace software applications. This paper explores the use of the UML language as a replacement for the English language for this purpose. Among the advantages offered by the Unified Modeling Language (UML) is a high degree of clarity and precision in the expression of domain concepts as well as architecture and design. Can this quality of UML be exploited for the definition of software requirements? While expressing logical behavior, interface characteristics, timeliness constraints, and other constraints on software using UML is commonly done and relatively straight-forward, achieving the additional aspects of the expression and management of software requirements that stakeholders expect, especially traceability, is far less so. These other characteristics, concerned with auditing and quality control, include the ability to trace a requirement to a parent requirement (which may well be an English "shall" statement), to trace a requirement to verification activities or scenarios which verify that requirement, and to trace a requirement to elements of the software design which implement that requirement. UML Use Cases, designed for capturing requirements, have not always been satisfactory. Some applications of them simply use the Use Case model element as a repository for English requirement statements. Other applications of Use Cases, in which Use Cases are incorporated into behavioral diagrams that successfully communicate the behaviors and constraints required of the software, do indeed take advantage of UML's clarity, but not in ways that support the traceability features mentioned above. Our approach uses the Stereotype construct of UML to precisely identify elements of UML constructs, especially behaviors such as State Machines and Activities, as requirements, and also to achieve the necessary mapping capabilities. We describe this approach in the context of a space-based software application currently under development at the Jet Propulsion Laboratory.
Assessing and Managing Quality of Information Assurance
2010-11-01
such as firewalls, antivirus scanning tools and mechanisms for user authentication and authorization. Advanced mission-critical systems often...imply increased risk to DoD information systems. The Process and Organizational Maturity (POM) class focuses on the maturity of the software and...include architectural quality. Common Weakness Enumeration (CWE) is a recent example that highlights the connection between software quality and
Software Engineering Guidebook
NASA Technical Reports Server (NTRS)
Connell, John; Wenneson, Greg
1993-01-01
The Software Engineering Guidebook describes SEPG (Software Engineering Process Group) supported processes and techniques for engineering quality software in NASA environments. Three process models are supported: structured, object-oriented, and evolutionary rapid-prototyping. The guidebook covers software life-cycles, engineering, assurance, and configuration management. The guidebook is written for managers and engineers who manage, develop, enhance, and/or maintain software under the Computer Software Services Contract.
Unassigned MS/MS Spectra: Who Am I?
Pathan, Mohashin; Samuel, Monisha; Keerthikumar, Shivakumar; Mathivanan, Suresh
2017-01-01
Recent advances in high resolution tandem mass spectrometry (MS) has resulted in the accumulation of high quality data. Paralleled with these advances in instrumentation, bioinformatics software have been developed to analyze such quality datasets. In spite of these advances, data analysis in mass spectrometry still remains critical for protein identification. In addition, the complexity of the generated MS/MS spectra, unpredictable nature of peptide fragmentation, sequence annotation errors, and posttranslational modifications has impeded the protein identification process. In a typical MS data analysis, about 60 % of the MS/MS spectra remains unassigned. While some of these could attribute to the low quality of the MS/MS spectra, a proportion can be classified as high quality. Further analysis may reveal how much of the unassigned MS spectra attribute to search space, sequence annotation errors, mutations, and/or posttranslational modifications. In this chapter, the tools used to identify proteins and ways to assign unassigned tandem MS spectra are discussed.
The role of metrics and measurements in a software intensive total quality management environment
NASA Technical Reports Server (NTRS)
Daniels, Charles B.
1992-01-01
Paramax Space Systems began its mission as a member of the Rockwell Space Operations Company (RSOC) team which was the successful bidder on a massive operations consolidation contract for the Mission Operations Directorate (MOD) at JSC. The contract awarded to the team was the Space Transportation System Operations Contract (STSOC). Our initial challenge was to accept responsibility for a very large, highly complex and fragmented collection of software from eleven different contractors and transform it into a coherent, operational baseline. Concurrently, we had to integrate a diverse group of people from eleven different companies into a single, cohesive team. Paramax executives recognized the absolute necessity to develop a business culture based on the concept of employee involvement to execute and improve the complex process of our new environment. Our executives clearly understood that management needed to set the example and lead the way to quality improvement. The total quality management policy and the metrics used in this endeavor are presented.
1982-03-01
pilot systems. Magnitude of the mutant error is classified as: o Program does not compute. o Program computes but does not run test data. o Program...14 Test and Integration ... ............ .. 105 15 The Mapping of SQM to the SDLC ........ ... 108 16 ADS Development .... .............. . 224 17...and funds. While the test phase concludes the normal development cycle, one should realize that with software the development continues in the
2011-05-27
frameworks 4 CMMI-DEV IEEE / ISO / IEC 15288 / 12207 Quality Assurance ©2011 Walz IEEE Life Cycle Processes & Artifacts • Systems Life Cycle Processes...TAG to ISO TC 176 Quality Management • Quality: ASQ, work experience • Software: three books, consulting, work experience • Systems: Telecom & DoD...and IEEE 730 SQA need to align. The P730 IEEE standards working group has expanded the scope of the SQA process standard to align with IS 12207
Quality and security - They work together
NASA Technical Reports Server (NTRS)
Carr, Richard; Tynan, Marie; Davis, Russell
1991-01-01
This paper describes the importance of considering computer security as part of software quality assurance practice. The intended audience is primarily those professionals involved in the design, development, and quality assurance of software. Many issues are raised which point to the need ultimately for integration of quality assurance and computer security disciplines. To address some of the issues raised, the NASA Automated Information Security program is presented as a model which may be used for improving interactions between the quality assurance and computer security community of professionals.
Ontology Based Quality Evaluation for Spatial Data
NASA Astrophysics Data System (ADS)
Yılmaz, C.; Cömert, Ç.
2015-08-01
Many institutions will be providing data to the National Spatial Data Infrastructure (NSDI). Current technical background of the NSDI is based on syntactic web services. It is expected that this will be replaced by semantic web services. The quality of the data provided is important in terms of the decision-making process and the accuracy of transactions. Therefore, the data quality needs to be tested. This topic has been neglected in Turkey. Data quality control for NSDI may be done by private or public "data accreditation" institutions. A methodology is required for data quality evaluation. There are studies for data quality including ISO standards, academic studies and software to evaluate spatial data quality. ISO 19157 standard defines the data quality elements. Proprietary software such as, 1Spatial's 1Validate and ESRI's Data Reviewer offers quality evaluation based on their own classification of rules. Commonly, rule based approaches are used for geospatial data quality check. In this study, we look for the technical components to devise and implement a rule based approach with ontologies using free and open source software in semantic web context. Semantic web uses ontologies to deliver well-defined web resources and make them accessible to end-users and processes. We have created an ontology conforming to the geospatial data and defined some sample rules to show how to test data with respect to data quality elements including; attribute, topo-semantic and geometrical consistency using free and open source software. To test data against rules, sample GeoSPARQL queries are created, associated with specifications.
Software Past, Present, and Future: Views from Government, Industry and Academia
NASA Technical Reports Server (NTRS)
Holcomb, Lee; Page, Jerry; Evangelist, Michael
2000-01-01
Views from the NASA CIO NASA Software Engineering Workshop on software development from the past, present, and future are presented. The topics include: 1) Software Past; 2) Software Present; 3) NASA's Largest Software Challenges; 4) 8330 Software Projects in Industry Standish Groups 1994 Report; 5) Software Future; 6) Capability Maturity Model (CMM): Software Engineering Institute (SEI) levels; 7) System Engineering Quality Also Part of the Problem; 8) University Environment Trends Will Increase the Problem in Software Engineering; and 9) NASA Software Engineering Goals.
NASA Astrophysics Data System (ADS)
Zemek, Peter G.; Plowman, Steven V.
2010-04-01
Advances in hardware have miniaturized the emissions spectrometer and associated optics, rendering them easily deployed in the field. Such systems are also suitable for vehicle mounting, and can provide high quality data and concentration information in minutes. Advances in software have accompanied this hardware evolution, enabling the development of portable point-and-click OP-FTIR systems that weigh less than 16 lbs. These systems are ideal for first-responders, military, law enforcement, forensics, and screening applications using optical remote sensing (ORS) methodologies. With canned methods and interchangeable detectors, the new generation of OP-FTIR technology is coupled to the latest forward reference-type model software to provide point-and-click technology. These software models have been established for some time. However, refined user-friendly models that use active, passive, and solar occultation methodologies now allow the user to quickly field-screen and quantify plumes, fence-lines, and combustion incident scenarios in high-temporal-resolution. Synthetic background generation is now redundant as the models use highly accurate instrument line shape (ILS) convolutions and several other parameters, in conjunction with radiative transfer model databases to model a single calibration spectrum to collected sample spectra. Data retrievals are performed directly on single beam spectra using non-linear classical least squares (NLCLS). Typically, the Hitran line database is used to generate the initial calibration spectrum contained within the software.
McCord, Layne K; Scarfe, William C; Naylor, Rachel H; Scheetz, James P; Silveira, Anibal; Gillespie, Kevin R
2007-05-01
The objectives of this study were to compare the effect of JPEG 2000 compression of hand-wrist radiographs on observer image quality qualitative assessment and to compare with a software-derived quantitative image quality index. Fifteen hand-wrist radiographs were digitized and saved as TIFF and JPEG 2000 images at 4 levels of compression (20:1, 40:1, 60:1, and 80:1). The images, including rereads, were viewed by 13 orthodontic residents who determined the image quality rating on a scale of 1 to 5. A quantitative analysis was also performed by using a readily available software based on the human visual system (Image Quality Measure Computer Program, version 6.2, Mitre, Bedford, Mass). ANOVA was used to determine the optimal compression level (P < or =.05). When we compared subjective indexes, JPEG compression greater than 60:1 significantly reduced image quality. When we used quantitative indexes, the JPEG 2000 images had lower quality at all compression ratios compared with the original TIFF images. There was excellent correlation (R2 >0.92) between qualitative and quantitative indexes. Image Quality Measure indexes are more sensitive than subjective image quality assessments in quantifying image degradation with compression. There is potential for this software-based quantitative method in determining the optimal compression ratio for any image without the use of subjective raters.
Comparison of methods for quantitative evaluation of endoscopic distortion
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Castro, Kurt; Desai, Viraj N.; Cheng, Wei-Chung; Pfefer, Joshua
2015-03-01
Endoscopy is a well-established paradigm in medical imaging, and emerging endoscopic technologies such as high resolution, capsule and disposable endoscopes promise significant improvements in effectiveness, as well as patient safety and acceptance of endoscopy. However, the field lacks practical standardized test methods to evaluate key optical performance characteristics (OPCs), in particular the geometric distortion caused by fisheye lens effects in clinical endoscopic systems. As a result, it has been difficult to evaluate an endoscope's image quality or assess its changes over time. The goal of this work was to identify optimal techniques for objective, quantitative characterization of distortion that are effective and not burdensome. Specifically, distortion measurements from a commercially available distortion evaluation/correction software package were compared with a custom algorithm based on a local magnification (ML) approach. Measurements were performed using a clinical gastroscope to image square grid targets. Recorded images were analyzed with the ML approach and the commercial software where the results were used to obtain corrected images. Corrected images based on the ML approach and the software were compared. The study showed that the ML method could assess distortion patterns more accurately than the commercial software. Overall, the development of standardized test methods for characterizing distortion and other OPCs will facilitate development, clinical translation, manufacturing quality and assurance of performance during clinical use of endoscopic technologies.
Proceedings of the Eighth Annual Software Engineering Workshop
NASA Technical Reports Server (NTRS)
1983-01-01
The four major topics of discussion included: the NASA Software Engineering Laboratory, software testing, human factors in software engineering and software quality assessment. As in the past years, there were 12 position papers presented (3 for each topic) followed by questions and very heavy participation by the general audience.
Modeling and managing risk early in software development
NASA Technical Reports Server (NTRS)
Briand, Lionel C.; Thomas, William M.; Hetmanski, Christopher J.
1993-01-01
In order to improve the quality of the software development process, we need to be able to build empirical multivariate models based on data collectable early in the software process. These models need to be both useful for prediction and easy to interpret, so that remedial actions may be taken in order to control and optimize the development process. We present an automated modeling technique which can be used as an alternative to regression techniques. We show how it can be used to facilitate the identification and aid the interpretation of the significant trends which characterize 'high risk' components in several Ada systems. Finally, we evaluate the effectiveness of our technique based on a comparison with logistic regression based models.
Markov chains for testing redundant software
NASA Technical Reports Server (NTRS)
White, Allan L.; Sjogren, Jon A.
1988-01-01
A preliminary design for a validation experiment has been developed that addresses several problems unique to assuring the extremely high quality of multiple-version programs in process-control software. The procedure uses Markov chains to model the error states of the multiple version programs. The programs are observed during simulated process-control testing, and estimates are obtained for the transition probabilities between the states of the Markov chain. The experimental Markov chain model is then expanded into a reliability model that takes into account the inertia of the system being controlled. The reliability of the multiple version software is computed from this reliability model at a given confidence level using confidence intervals obtained for the transition probabilities during the experiment. An example demonstrating the method is provided.
3D Fiber Orientation Simulation for Plastic Injection Molding
NASA Astrophysics Data System (ADS)
Lin, Baojiu; Jin, Xiaoshi; Zheng, Rong; Costa, Franco S.; Fan, Zhiliang
2004-06-01
Glass fiber reinforced polymer is widely used in the products made using injection molding processing. The distribution of fiber orientation inside plastic parts has direct effects on quality of molded parts. Using computer simulation to predict fiber orientation distribution is one of most efficient ways to assist engineers to do warpage analysis and to find a good design solution to produce high quality plastic parts. Fiber orientation simulation software based on 2-1/2D (midplane /Dual domain mesh) techniques has been used in industry for a decade. However, the 2-1/2D technique is based on the planar Hele-Shaw approximation and it is not suitable when the geometry has complex three-dimensional features which cannot be well approximated by 2D shells. Recently, a full 3D simulation software for fiber orientation has been developed and integrated into Moldflow Plastics Insight 3D simulation software. The theory for this new 3D fiber orientation calculation module is described in this paper. Several examples are also presented to show the benefit in using 3D fiber orientation simulation.
Assembly of cucumber (Cucumis sativus L.) somaclones
NASA Astrophysics Data System (ADS)
Skarzyńska, Agnieszka; Kuśmirek, Wiktor; Pawełkowicz, Magdalena; PlÄ der, Wojciech; Nowak, Robert M.
2017-08-01
The development of next generation sequencing opens the possibility of using sequencing in various plant studies, such as finding structural changes and small polymorphisms between species and within them. Most analyzes rely on genomic sequences and it is crucial to use well-assembled genomes of high quality and completeness. Herein we compare commonly available programs for genomic assembling and newly developed software - dnaasm. Assemblies were tested on cucumber (Cucumis sativus L.) lines obtained by in vitro regeneration (somaclones), showing different phenotypes. Obtained results shows that dnaasm assembler is a good tool for short read assembly, which allows obtaining genomes of high quality and completeness.
78 FR 25482 - Notice of Revised Determination on Reconsideration
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-01
...-PROGRESSIVE SOFTWARE COMPUTING, QUALITY TESTING SERVICES, INC., RAILROAD CONSTRUCTION CO. OF SOUTH JERSEY, INC..., LP, PSCI- Progressive Software Computing, Quality Testing Services, Inc., Railroad Construction Co..., ANDERSON CONSTRUCTION SERVICES, BAKER PETROLITE, BAKERCORP, BELL-FAST FIRE PROTECTION INC., BOLTTECH INC...
Data quality can make or break a research infrastructure
NASA Astrophysics Data System (ADS)
Pastorello, G.; Gunter, D.; Chu, H.; Christianson, D. S.; Trotta, C.; Canfora, E.; Faybishenko, B.; Cheah, Y. W.; Beekwilder, N.; Chan, S.; Dengel, S.; Keenan, T. F.; O'Brien, F.; Elbashandy, A.; Poindexter, C.; Humphrey, M.; Papale, D.; Agarwal, D.
2017-12-01
Research infrastructures (RIs) commonly support observational data provided by multiple, independent sources. Uniformity in the data distributed by such RIs is important in most applications, e.g., in comparative studies using data from two or more sources. Achieving uniformity in terms of data quality is challenging, especially considering that many data issues are unpredictable and cannot be detected until a first occurrence of the issue. With that, many data quality control activities within RIs require a manual, human-in-the-loop element, making it an expensive activity. Our motivating example is the FLUXNET2015 dataset - a collection of ecosystem-level carbon, water, and energy fluxes between land and atmosphere from over 200 sites around the world, some sites with over 20 years of data. About 90% of the human effort to create the dataset was spent in data quality related activities. Based on this experience, we have been working on solutions to increase the automation of data quality control procedures. Since it is nearly impossible to fully automate all quality related checks, we have been drawing from the experience with techniques used in software development, which shares a few common constraints. In both managing scientific data and writing software, human time is a precious resource; code bases, as Science datasets, can be large, complex, and full of errors; both scientific and software endeavors can be pursued by individuals, but collaborative teams can accomplish a lot more. The lucrative and fast-paced nature of the software industry fueled the creation of methods and tools to increase automation and productivity within these constraints. Issue tracking systems, methods for translating problems into automated tests, powerful version control tools are a few examples. Terrestrial and aquatic ecosystems research relies heavily on many types of observational data. As volumes of data collection increases, ensuring data quality is becoming an unwieldy challenge for RIs. Business as usual approaches to data quality do not work with larger data volumes. We believe RIs can benefit greatly from adapting and imitating this body of theory and practice from software quality into data quality, enabling systematic and reproducible safeguards against errors and mistakes in datasets as much as in software.
Robertson, Thomas E; Levine, Andrea R; Verceles, Avelino C; Buchner, Jessica A; Lantry, James H; Papali, Alfred; Zubrow, Marc T; Colas, L Nathalie; Augustin, Marc E; McCurdy, Michael T
2017-08-01
Ultrasound (US) is a burgeoning diagnostic tool and is often the only available imaging modality in low- and middle-income countries (LMICs). However, bedside providers often lack training to acquire or interpret US images. We conducted a study to determine if a remote tele-intensivist could mentor geographically removed LMIC providers to obtain quality and clinically useful US images. Nine Haitian non-physician health care workers received a 20-minute training on basic US techniques. A volunteer was connected to an intensivist located in the USA via FaceTime. The intensivist remotely instructed the non-physicians to ultrasound five anatomic sites. The tele-intensivist evaluated the image quality and clinical utility of performing tele-ultrasound in a LMIC. The intensivist agreed (defined as "agree" or "strongly agree" on a five-point Likert scale) that 90% (57/63) of the FaceTime images were high quality. The intensivist felt comfortable making clinical decisions using FaceTime images 89% (56/63) of the time. Non-physicians can feasibly obtain high-quality and clinically relevant US images using video chat software in LMICs. Commercially available software can connect providers in institutions in LMICs to geographically removed intensivists at a relatively low cost and without the need for extensive training of local providers. Copyright © 2017 Elsevier Inc. All rights reserved.
Analyzing longitudinal data with the linear mixed models procedure in SPSS.
West, Brady T
2009-09-01
Many applied researchers analyzing longitudinal data share a common misconception: that specialized statistical software is necessary to fit hierarchical linear models (also known as linear mixed models [LMMs], or multilevel models) to longitudinal data sets. Although several specialized statistical software programs of high quality are available that allow researchers to fit these models to longitudinal data sets (e.g., HLM), rapid advances in general purpose statistical software packages have recently enabled analysts to fit these same models when using preferred packages that also enable other more common analyses. One of these general purpose statistical packages is SPSS, which includes a very flexible and powerful procedure for fitting LMMs to longitudinal data sets with continuous outcomes. This article aims to present readers with a practical discussion of how to analyze longitudinal data using the LMMs procedure in the SPSS statistical software package.
Web-based Quality Control Tool used to validate CERES products on a cluster of Linux servers
NASA Astrophysics Data System (ADS)
Chu, C.; Sun-Mack, S.; Heckert, E.; Chen, Y.; Mlynczak, P.; Mitrescu, C.; Doelling, D.
2014-12-01
There have been a few popular desktop tools used in the Earth Science community to validate science data. Because of the limitation on the capacity of desktop hardware such as disk space and CPUs, those softwares are not able to display large amount of data from files.This poster will talk about an in-house developed web-based software built on a cluster of Linux servers. That allows users to take advantage of a few Linux servers working in parallel to generate hundreds images in a short period of time. The poster will demonstrate:(1) The hardware and software architecture is used to provide high throughput of images. (2) The software structure that can incorporate new products and new requirement quickly. (3) The user interface about how users can manipulate the data and users can control how the images are displayed.
An Investigation of Techniques for Detecting Data Anomalies in Earned Value Management Data
2011-12-01
Management Studio Harte Hanks Trillium Software Trillium Software System IBM Info Sphere Foundation Tools Informatica Data Explorer Informatica ...Analyst Informatica Developer Informatica Administrator Pitney Bowes Business Insight Spectrum SAP BusinessObjects Data Quality Management DataFlux...menting quality monitoring efforts and tracking data quality improvements Informatica http://www.informatica.com/products_services/Pages/index.aspx
Software Architecture Evolution
ERIC Educational Resources Information Center
Barnes, Jeffrey M.
2013-01-01
Many software systems eventually undergo changes to their basic architectural structure. Such changes may be prompted by new feature requests, new quality attribute requirements, changing technology, or other reasons. Whatever the causes, architecture evolution is commonplace in real-world software projects. Today's software architects, however,…
Telemedicine using free voice over internet protocol (VoIP) technology.
Miller, David J; Miljkovic, Nikola; Chiesa, Chad; Callahan, John B; Webb, Brad; Boedeker, Ben H
2011-01-01
Though dedicated videoteleconference (VTC) systems deliver high quality, low-latency audio and video for telemedical applications, they require expensive hardware and extensive infrastructure. The purpose of this study was to investigate free commercially available Voice over Internet Protocol (VoIP) software as a low cost alternative for telemedicine.
LiveDescribe: Can Amateur Describers Create High-Quality Audio Description?
ERIC Educational Resources Information Center
Branje, Carmen J.; Fels, Deborah I.
2012-01-01
Introduction: The study presented here evaluated the usability of the audio description software LiveDescribe and explored the acceptance rates of audio description created by amateur describers who used LiveDescribe to facilitate the creation of their descriptions. Methods: Twelve amateur describers with little or no previous experience with…
Development of Course Material in a Multi-Author Environment
ERIC Educational Resources Information Center
Schlotter, Michael
2009-01-01
Software for text processing and presentation design is becoming increasingly sophisticated. Nevertheless, it is difficult to find a good solution for collaborative writing of technical course material, allowing the creation of high quality lecture notes and presentation slides from a single source. This article presents a new editing framework…
Marine beaches are occasionally contaminated by unacceptably high levels of fecal indicator bacteria (FIB) that exceed EPA water quality criteria. Here we describe application of a recent version of the software package Virtual Beach tool (VB 3.0.6) to build and evaluate multiple...
APQ-102 imaging radar digital image quality study
NASA Technical Reports Server (NTRS)
Griffin, C. R.; Estes, J. M.
1982-01-01
A modified APQ-102 sidelooking radar collected synthetic aperture radar (SAR) data which was digitized and recorded on wideband magnetic tape. These tapes were then ground processed into computer compatible tapes (CCT's). The CCT's may then be processed into high resolution radar images by software on the CYBER computer.
UrQt: an efficient software for the Unsupervised Quality trimming of NGS data.
Modolo, Laurent; Lerat, Emmanuelle
2015-04-29
Quality control is a necessary step of any Next Generation Sequencing analysis. Although customary, this step still requires manual interventions to empirically choose tuning parameters according to various quality statistics. Moreover, current quality control procedures that provide a "good quality" data set, are not optimal and discard many informative nucleotides. To address these drawbacks, we present a new quality control method, implemented in UrQt software, for Unsupervised Quality trimming of Next Generation Sequencing reads. Our trimming procedure relies on a well-defined probabilistic framework to detect the best segmentation between two segments of unreliable nucleotides, framing a segment of informative nucleotides. Our software only requires one user-friendly parameter to define the minimal quality threshold (phred score) to consider a nucleotide to be informative, which is independent of both the experiment and the quality of the data. This procedure is implemented in C++ in an efficient and parallelized software with a low memory footprint. We tested the performances of UrQt compared to the best-known trimming programs, on seven RNA and DNA sequencing experiments and demonstrated its optimality in the resulting tradeoff between the number of trimmed nucleotides and the quality objective. By finding the best segmentation to delimit a segment of good quality nucleotides, UrQt greatly increases the number of reads and of nucleotides that can be retained for a given quality objective. UrQt source files, binary executables for different operating systems and documentation are freely available (under the GPLv3) at the following address: https://lbbe.univ-lyon1.fr/-UrQt-.html .
1990-02-01
inspections are performed before each formal review of each software life cycle phase. * Required software audits are performed . " The software is acceptable... Audits : Software audits are performed bySQA consistent with thegeneral audit rules and an auditreportis prepared. Software Quality Inspection (SQI...DSD Software Development Method 3-34 DEFINITION OF ACRONYMS Acronym Full Name or Description MACH Methode d’Analyse et de Conception Flierarchisee
An improved real time superresolution FPGA system
NASA Astrophysics Data System (ADS)
Lakshmi Narasimha, Pramod; Mudigoudar, Basavaraj; Yue, Zhanfeng; Topiwala, Pankaj
2009-05-01
In numerous computer vision applications, enhancing the quality and resolution of captured video can be critical. Acquired video is often grainy and low quality due to motion, transmission bottlenecks, etc. Postprocessing can enhance it. Superresolution greatly decreases camera jitter to deliver a smooth, stabilized, high quality video. In this paper, we extend previous work on a real-time superresolution application implemented in ASIC/FPGA hardware. A gradient based technique is used to register the frames at the sub-pixel level. Once we get the high resolution grid, we use an improved regularization technique in which the image is iteratively modified by applying back-projection to get a sharp and undistorted image. The algorithm was first tested in software and migrated to hardware, to achieve 320x240 -> 1280x960, about 30 fps, a stunning superresolution by 16X in total pixels. Various input parameters, such as size of input image, enlarging factor and the number of nearest neighbors, can be tuned conveniently by the user. We use a maximum word size of 32 bits to implement the algorithm in Matlab Simulink as well as in FPGA hardware, which gives us a fine balance between the number of bits and performance. The proposed system is robust and highly efficient. We have shown the performance improvement of the hardware superresolution over the software version (C code).
Effective Software Engineering Leadership for Development Programs
ERIC Educational Resources Information Center
Cagle West, Marsha
2010-01-01
Software is a critical component of systems ranging from simple consumer appliances to complex health, nuclear, and flight control systems. The development of quality, reliable, and effective software solutions requires the incorporation of effective software engineering processes and leadership. Processes, approaches, and methodologies for…
Quality assurance software inspections at NASA Ames: Metrics for feedback and modification
NASA Technical Reports Server (NTRS)
Wenneson, G.
1985-01-01
Software inspections are a set of formal technical review procedures held at selected key points during software development in order to find defects in software documents--is described in terms of history, participants, tools, procedures, statistics, and database analysis.
GenePRIMP: A software quality control tool
Amrita Pati
2017-12-09
Amrita Pati of the DOE Joint Genome Institute's Genome Biology group describes the software tool GenePRIMP and how it fits into the quality control pipeline for microbial genomics. Further details regarding GenePRIMP appear in a paper published online May 2, 2010 in Nature Methods.
State of the art metrics for aspect oriented programming
NASA Astrophysics Data System (ADS)
Ghareb, Mazen Ismaeel; Allen, Gary
2018-04-01
The quality evaluation of software, e.g., defect measurement, gains significance with higher use of software applications. Metric measurements are considered as the primary indicator of imperfection prediction and software maintenance in various empirical studies of software products. However, there is no agreement on which metrics are compelling quality indicators for novel development approaches such as Aspect Oriented Programming (AOP). AOP intends to enhance programming quality, by providing new and novel constructs for the development of systems, for example, point cuts, advice and inter-type relationships. Hence, it is not evident if quality pointers for AOP can be derived from direct expansions of traditional OO measurements. Then again, investigations of AOP do regularly depend on established coupling measurements. Notwithstanding the late reception of AOP in empirical studies, coupling measurements have been adopted as useful markers of flaw inclination in this context. In this paper we will investigate the state of the art metrics for measurement of Aspect Oriented systems development.
A proposed classification scheme for Ada-based software products
NASA Technical Reports Server (NTRS)
Cernosek, Gary J.
1986-01-01
As the requirements for producing software in the Ada language become a reality for projects such as the Space Station, a great amount of Ada-based program code will begin to emerge. Recognizing the potential for varying levels of quality to result in Ada programs, what is needed is a classification scheme that describes the quality of a software product whose source code exists in Ada form. A 5-level classification scheme is proposed that attempts to decompose this potentially broad spectrum of quality which Ada programs may possess. The number of classes and their corresponding names are not as important as the mere fact that there needs to be some set of criteria from which to evaluate programs existing in Ada. An exact criteria for each class is not presented, nor are any detailed suggestions of how to effectively implement this quality assessment. The idea of Ada-based software classification is introduced and a set of requirements from which to base further research and development is suggested.
Web Implementation of Quality Assurance (QA) for X-ray Units in Balkanic Medical Institutions.
Urošević, Vlade; Ristić, Olga; Milošević, Danijela; Košutić, Duško
2015-08-01
Diagnostic radiology is the major contributor to the total dose of the population from all artificial sources. In order to reduce radiation exposure and optimize diagnostic x-ray image quality, it is necessary to increase the quality and efficiency of quality assurance (QA) and audit programs. This work presents a web application providing completely new QA solutions for x-ray modalities and facilities. The software gives complete online information (using European standards) with which the corresponding institutions and individuals can evaluate and control a facility's Radiation Safety and QA program. The software enables storage of all data in one place and sharing the same information (data), regardless of whether the measured data is used by an individual user or by an authorized institution. The software overcomes the distance and time separation of institutions and individuals who take part in QA. Upgrading the software will enable assessment of the medical exposure level to ionizing radiation.
Third-Party Software's Trust Quagmire.
Voas, J; Hurlburt, G
2015-12-01
Current software development has trended toward the idea of integrating independent software sub-functions to create more complete software systems. Software sub-functions are often not homegrown - instead they are developed by unknown 3 rd party organizations and reside in software marketplaces owned or controlled by others. Such software sub-functions carry plausible concern in terms of quality, origins, functionality, security, interoperability, to name a few. This article surveys key technical difficulties in confidently building systems from acquired software sub-functions by calling out the principle software supply chain actors.
Blank, Antje; Prytherch, Helen; Kaltschmidt, Jens; Krings, Andreas; Sukums, Felix; Mensah, Nathan; Zakane, Alphonse; Loukanova, Svetla; Gustafsson, Lars L; Sauerborn, Rainer; Haefeli, Walter E
2013-04-10
Despite strong efforts to improve maternal care, its quality remains deficient in many countries of Sub-Saharan Africa as persistently high maternal mortality rates testify. The QUALMAT study seeks to improve the performance and motivation of rural health workers and ultimately quality of primary maternal health care services in three African countries Burkina Faso, Ghana, and Tanzania. One major intervention is the introduction of a computerized Clinical Decision Support System (CDSS) for rural primary health care centers to be used by health care workers of different educational levels. A stand-alone, java-based software, able to run on any standard hardware, was developed based on assessment of the health care situation in the involved countries. The software scope was defined and the final software was programmed under consideration of test experiences. Knowledge for the decision support derived from the World Health Organization (WHO) guideline "Pregnancy, Childbirth, Postpartum and Newborn Care; A Guide for Essential Practice". The QUALMAT CDSS provides computerized guidance and clinical decision support for antenatal care, and care during delivery and up to 24 hours post delivery. The decision support is based on WHO guidelines and designed using three principles: (1) Guidance through routine actions in maternal and perinatal care, (2) integration of clinical data to detect situations of concern by algorithms, and (3) electronic tracking of peri- and postnatal activities. In addition, the tool facilitates patient management and is a source of training material. The implementation of the software, which is embedded in a set of interventions comprising the QUALMAT study, is subject to various research projects assessing and quantifying the impact of the CDSS on quality of care, the motivation of health care staff (users) and its health economic aspects. The software will also be assessed for its usability and acceptance, as well as for its influence on workflows in the rural setting of primary health care in the three countries involved. The development and implementation of a CDSS in rural primary health care centres presents challenges, which may be overcome with careful planning and involvement of future users at an early stage. A tailored software with stable functionality should offer perspectives to improve maternal care in resource-poor settings.
2013-01-01
Background Despite strong efforts to improve maternal care, its quality remains deficient in many countries of Sub-Saharan Africa as persistently high maternal mortality rates testify. The QUALMAT study seeks to improve the performance and motivation of rural health workers and ultimately quality of primary maternal health care services in three African countries Burkina Faso, Ghana, and Tanzania. One major intervention is the introduction of a computerized Clinical Decision Support System (CDSS) for rural primary health care centers to be used by health care workers of different educational levels. Methods A stand-alone, java-based software, able to run on any standard hardware, was developed based on assessment of the health care situation in the involved countries. The software scope was defined and the final software was programmed under consideration of test experiences. Knowledge for the decision support derived from the World Health Organization (WHO) guideline “Pregnancy, Childbirth, Postpartum and Newborn Care; A Guide for Essential Practice”. Results The QUALMAT CDSS provides computerized guidance and clinical decision support for antenatal care, and care during delivery and up to 24 hours post delivery. The decision support is based on WHO guidelines and designed using three principles: (1) Guidance through routine actions in maternal and perinatal care, (2) integration of clinical data to detect situations of concern by algorithms, and (3) electronic tracking of peri- and postnatal activities. In addition, the tool facilitates patient management and is a source of training material. The implementation of the software, which is embedded in a set of interventions comprising the QUALMAT study, is subject to various research projects assessing and quantifying the impact of the CDSS on quality of care, the motivation of health care staff (users) and its health economic aspects. The software will also be assessed for its usability and acceptance, as well as for its influence on workflows in the rural setting of primary health care in the three countries involved. Conclusion The development and implementation of a CDSS in rural primary health care centres presents challenges, which may be overcome with careful planning and involvement of future users at an early stage. A tailored software with stable functionality should offer perspectives to improve maternal care in resource-poor settings. Trial registration http://www.clinicaltrials.gov/NCT01409824. PMID:23574764
Software metrics: The key to quality software on the NCC project
NASA Technical Reports Server (NTRS)
Burns, Patricia J.
1993-01-01
Network Control Center (NCC) Project metrics are captured during the implementation and testing phases of the NCCDS software development lifecycle. The metrics data collection and reporting function has interfaces with all elements of the NCC project. Close collaboration with all project elements has resulted in the development of a defined and repeatable set of metrics processes. The resulting data are used to plan and monitor release activities on a weekly basis. The use of graphical outputs facilitates the interpretation of progress and status. The successful application of metrics throughout the NCC project has been instrumental in the delivery of quality software. The use of metrics on the NCC Project supports the needs of the technical and managerial staff. This paper describes the project, the functions supported by metrics, the data that are collected and reported, how the data are used, and the improvements in the quality of deliverable software since the metrics processes and products have been in use.
Software reliability models for fault-tolerant avionics computers and related topics
NASA Technical Reports Server (NTRS)
Miller, Douglas R.
1987-01-01
Software reliability research is briefly described. General research topics are reliability growth models, quality of software reliability prediction, the complete monotonicity property of reliability growth, conceptual modelling of software failure behavior, assurance of ultrahigh reliability, and analysis techniques for fault-tolerant systems.
Quantitative evaluation of software packages for single-molecule localization microscopy.
Sage, Daniel; Kirshner, Hagai; Pengo, Thomas; Stuurman, Nico; Min, Junhong; Manley, Suliana; Unser, Michael
2015-08-01
The quality of super-resolution images obtained by single-molecule localization microscopy (SMLM) depends largely on the software used to detect and accurately localize point sources. In this work, we focus on the computational aspects of super-resolution microscopy and present a comprehensive evaluation of localization software packages. Our philosophy is to evaluate each package as a whole, thus maintaining the integrity of the software. We prepared synthetic data that represent three-dimensional structures modeled after biological components, taking excitation parameters, noise sources, point-spread functions and pixelation into account. We then asked developers to run their software on our data; most responded favorably, allowing us to present a broad picture of the methods available. We evaluated their results using quantitative and user-interpretable criteria: detection rate, accuracy, quality of image reconstruction, resolution, software usability and computational resources. These metrics reflect the various tradeoffs of SMLM software packages and help users to choose the software that fits their needs.
The software product assurance metrics study: JPL's software systems quality and productivity
NASA Technical Reports Server (NTRS)
Bush, Marilyn W.
1989-01-01
The findings are reported of the Jet Propulsion Laboratory (JPL)/Software Product Assurance (SPA) Metrics Study, conducted as part of a larger JPL effort to improve software quality and productivity. Until recently, no comprehensive data had been assembled on how JPL manages and develops software-intensive systems. The first objective was to collect data on software development from as many projects and for as many years as possible. Results from five projects are discussed. These results reflect 15 years of JPL software development, representing over 100 data points (systems and subsystems), over a third of a billion dollars, over four million lines of code and 28,000 person months. Analysis of this data provides a benchmark for gauging the effectiveness of past, present and future software development work. In addition, the study is meant to encourage projects to record existing metrics data and to gather future data. The SPA long term goal is to integrate the collection of historical data and ongoing project data with future project estimations.
NASA Astrophysics Data System (ADS)
Sheldon, W.; Chamblee, J.; Cary, R. H.
2013-12-01
Environmental scientists are under increasing pressure from funding agencies and journal publishers to release quality-controlled data in a timely manner, as well as to produce comprehensive metadata for submitting data to long-term archives (e.g. DataONE, Dryad and BCO-DMO). At the same time, the volume of digital data that researchers collect and manage is increasing rapidly due to advances in high frequency electronic data collection from flux towers, instrumented moorings and sensor networks. However, few pre-built software tools are available to meet these data management needs, and those tools that do exist typically focus on part of the data management lifecycle or one class of data. The GCE Data Toolbox has proven to be both a generalized and effective software solution for environmental data management in the Long Term Ecological Research Network (LTER). This open source MATLAB software library, developed by the Georgia Coastal Ecosystems LTER program, integrates metadata capture, creation and management with data processing, quality control and analysis to support the entire data lifecycle. Raw data can be imported directly from common data logger formats (e.g. SeaBird, Campbell Scientific, YSI, Hobo), as well as delimited text files, MATLAB files and relational database queries. Basic metadata are derived from the data source itself (e.g. parsed from file headers) and by value inspection, and then augmented using editable metadata templates containing boilerplate documentation, attribute descriptors, code definitions and quality control rules. Data and metadata content, quality control rules and qualifier flags are then managed together in a robust data structure that supports database functionality and ensures data validity throughout processing. A growing suite of metadata-aware editing, quality control, analysis and synthesis tools are provided with the software to support managing data using graphical forms and command-line functions, as well as developing automated workflows for unattended processing. Finalized data and structured metadata can be exported in a wide variety of text and MATLAB formats or uploaded to a relational database for long-term archiving and distribution. The GCE Data Toolbox can be used as a complete, light-weight solution for environmental data and metadata management, but it can also be used in conjunction with other cyber infrastructure to provide a more comprehensive solution. For example, newly acquired data can be retrieved from a Data Turbine or Campbell LoggerNet Database server for quality control and processing, then transformed to CUAHSI Observations Data Model format and uploaded to a HydroServer for distribution through the CUAHSI Hydrologic Information System. The GCE Data Toolbox can also be leveraged in analytical workflows developed using Kepler or other systems that support MATLAB integration or tool chaining. This software can therefore be leveraged in many ways to help researchers manage, analyze and distribute the data they collect.
Astronomy Data Visualization with Blender
NASA Astrophysics Data System (ADS)
Kent, Brian R.
2015-08-01
We present innovative methods and techniques for using Blender, a 3D software package, in the visualization of astronomical data. N-body simulations, data cubes, galaxy and stellar catalogs, and planetary surface maps can be rendered in high quality videos for exploratory data analysis. Blender's API is Python based, making it advantageous for use in astronomy with flexible libraries like astroPy. Examples will be exhibited that showcase the features of the software in astronomical visualization paradigms. 2D and 3D voxel texture applications, animations, camera movement, and composite renders are introduced to the astronomer's toolkit and how they mesh with different forms of data.
Romero, Peggy; Miller, Ted; Garakani, Arman
2009-12-01
Current methods to assess neurodegradation in dorsal root ganglion cultures as a model for neurodegenerative diseases are imprecise and time-consuming. Here we describe two new methods to quantify neuroprotection in these cultures. The neurite quality index (NQI) builds upon earlier manual methods, incorporating additional morphological events to increase detection sensitivity for the detection of early degeneration events. Neurosight is a machine vision-based method that recapitulates many of the strengths of NQI while enabling high-throughput screening applications with decreased costs.
[The development and evaluation of software to verify diagnostic accuracy].
Jensen, Rodrigo; de Moraes Lopes, Maria Helena Baena; Silveira, Paulo Sérgio Panse; Ortega, Neli Regina Siqueira
2012-02-01
This article describes the development and evaluation of software that verifies the accuracy of diagnoses made by nursing students. The software was based on a model that uses fuzzy logic concepts, including PERL, the MySQL database for Internet accessibility, and the NANDA-I 2007-2008 classification system. The software was evaluated in terms of its technical quality and usability through specific instruments. The activity proposed in the software involves four stages in which students establish the relationship values between nursing diagnoses, defining characteristics/risk factors and clinical cases. The relationship values determined by students are compared to those of specialists, generating performance scores for the students. In the evaluation, the software demonstrated satisfactory outcomes regarding the technical quality and, according to the students, helped in their learning and may become an educational tool to teach the process of nursing diagnosis.
A Quantitative Analysis of Open Source Software's Acceptability as Production-Quality Code
ERIC Educational Resources Information Center
Fischer, Michael
2011-01-01
The difficulty in writing defect-free software has been long acknowledged both by academia and industry. A constant battle occurs as developers seek to craft software that works within aggressive business schedules and deadlines. Many tools and techniques are used in attempt to manage these software projects. Software metrics are a tool that has…
A Heuristic for Improving Legacy Software Quality during Maintenance: An Empirical Case Study
ERIC Educational Resources Information Center
Sale, Michael John
2017-01-01
Many organizations depend on the functionality of mission-critical legacy software and the continued maintenance of this software is vital. Legacy software is defined here as software that contains no testing suite, is often foreign to the developer performing the maintenance, lacks meaningful documentation, and over time, has become difficult to…
Practical Methods for Estimating Software Systems Fault Content and Location
NASA Technical Reports Server (NTRS)
Nikora, A.; Schneidewind, N.; Munson, J.
1999-01-01
Over the past several years, we have developed techniques to discriminate between fault-prone software modules and those that are not, to estimate a software system's residual fault content, to identify those portions of a software system having the highest estimated number of faults, and to estimate the effects of requirements changes on software quality.
Earth Observing System (EOS)/Advanced Microwave Sounding Unit-A (AMSU-A) software assurance plan
NASA Technical Reports Server (NTRS)
Schwantje, Robert; Smith, Claude
1994-01-01
This document defines the responsibilities of Software Quality Assurance (SOA) for the development of the flight software installed in EOS/AMSU-A instruments, and the ground support software used in the test and integration of the EOS/AMSU-A instruments.
NASA Technical Reports Server (NTRS)
Butler, C. M.; Hogge, J. E.
1978-01-01
Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.
Large scale database scrubbing using object oriented software components.
Herting, R L; Barnes, M R
1998-01-01
Now that case managers, quality improvement teams, and researchers use medical databases extensively, the ability to share and disseminate such databases while maintaining patient confidentiality is paramount. A process called scrubbing addresses this problem by removing personally identifying information while keeping the integrity of the medical information intact. Scrubbing entire databases, containing multiple tables, requires that the implicit relationships between data elements in different tables of the database be maintained. To address this issue we developed DBScrub, a Java program that interfaces with any JDBC compliant database and scrubs the database while maintaining the implicit relationships within it. DBScrub uses a small number of highly configurable object-oriented software components to carry out the scrubbing. We describe the structure of these software components and how they maintain the implicit relationships within the database.
Fast and predictable video compression in software design and implementation of an H.261 codec
NASA Astrophysics Data System (ADS)
Geske, Dagmar; Hess, Robert
1998-09-01
The use of software codecs for video compression becomes commonplace in several videoconferencing applications. In order to reduce conflicts with other applications used at the same time, mechanisms for resource reservation on endsystems need to determine an upper bound for computing time used by the codec. This leads to the demand for predictable execution times of compression/decompression. Since compression schemes as H.261 inherently depend on the motion contained in the video, an adaptive admission control is required. This paper presents a data driven approach based on dynamical reduction of the number of processed macroblocks in peak situations. Besides the absolute speed is a point of interest. The question, whether and how software compression of high quality video is feasible on today's desktop computers, is examined.
Initial Ada components evaluation
NASA Technical Reports Server (NTRS)
Moebes, Travis
1989-01-01
The SAIC has the responsibility for independent test and validation of the SSE. They have been using a mathematical functions library package implemented in Ada to test the SSE IV and V process. The library package consists of elementary mathematical functions and is both machine and accuracy independent. The SSE Ada components evaluation includes code complexity metrics based on Halstead's software science metrics and McCabe's measure of cyclomatic complexity. Halstead's metrics are based on the number of operators and operands on a logical unit of code and are compiled from the number of distinct operators, distinct operands, and total number of occurrences of operators and operands. These metrics give an indication of the physical size of a program in terms of operators and operands and are used diagnostically to point to potential problems. McCabe's Cyclomatic Complexity Metrics (CCM) are compiled from flow charts transformed to equivalent directed graphs. The CCM is a measure of the total number of linearly independent paths through the code's control structure. These metrics were computed for the Ada mathematical functions library using Software Automated Verification and Validation (SAVVAS), the SSE IV and V tool. A table with selected results was shown, indicating that most of these routines are of good quality. Thresholds for the Halstead measures indicate poor quality if the length metric exceeds 260 or difficulty is greater than 190. The McCabe CCM indicated a high quality of software products.
Generating Safety-Critical PLC Code From a High-Level Application Software Specification
NASA Technical Reports Server (NTRS)
2008-01-01
The benefits of automatic-application code generation are widely accepted within the software engineering community. These benefits include raised abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at Kennedy Space Center recognized the need for PLC code generation while developing the new ground checkout and launch processing system, called the Launch Control System (LCS). Engineers developed a process and a prototype software tool that automatically translates a high-level representation or specification of application software into ladder logic that executes on a PLC. All the computer hardware in the LCS is planned to be commercial off the shelf (COTS), including industrial controllers or PLCs that are connected to the sensors and end items out in the field. Most of the software in LCS is also planned to be COTS, with only small adapter software modules that must be developed in order to interface between the various COTS software products. A domain-specific language (DSL) is a programming language designed to perform tasks and to solve problems in a particular domain, such as ground processing of launch vehicles. The LCS engineers created a DSL for developing test sequences of ground checkout and launch operations of future launch vehicle and spacecraft elements, and they are developing a tabular specification format that uses the DSL keywords and functions familiar to the ground and flight system users. The tabular specification format, or tabular spec, allows most ground and flight system users to document how the application software is intended to function and requires little or no software programming knowledge or experience. A small sample from a prototype tabular spec application is shown.
Utah's Regional/Urban ANSS Seismic Network---Strategies and Tools for Quality Performance
NASA Astrophysics Data System (ADS)
Burlacu, R.; Arabasz, W. J.; Pankow, K. L.; Pechmann, J. C.; Drobeck, D. L.; Moeinvaziri, A.; Roberson, P. M.; Rusho, J. A.
2007-05-01
The University of Utah's regional/urban seismic network (224 stations recorded: 39 broadband, 87 strong-motion, 98 short-period) has become a model for locally implementing the Advanced National Seismic System (ANSS) because of successes in integrating weak- and strong-motion recording and in developing an effective real-time earthquake information system. Early achievements included implementing ShakeMap, ShakeCast, point-to- multipoint digital telemetry, and an Earthworm Oracle database, as well as in-situ calibration of all broadband and strong-motion stations and submission of all data and metadata into the IRIS DMC. Regarding quality performance, our experience as a medium-size regional network affirms the fundamental importance of basics such as the following: for data acquisition, deliberate attention to high-quality field installations, signal quality, and computer operations; for operational efficiency, a consistent focus on professional project management and human resources; and for customer service, healthy partnerships---including constant interactions with emergency managers, engineers, public policy-makers, and other stakeholders as part of an effective state earthquake program. (Operational cost efficiencies almost invariably involve trade-offs between personnel costs and the quality of hardware and software.) Software tools that we currently rely on for quality performance include those developed by UUSS (e.g., SAC and shell scripts for estimating local magnitudes) and software developed by other organizations such as: USGS (Earthworm), University of Washington (interactive analysis software), ISTI (SeisNetWatch), and IRIS (PDCC, BUD tools). Although there are many pieces, there is little integration. One of the main challenges we face is the availability of a complete and coherent set of tools for automatic and post-processing to assist in achieving the goals/requirements set forth by ANSS. Taking our own network---and ANSS---to the next level will require standardized, well-designed, and supported software. Other advances in seismic network performance will come from diversified instrumentation. We have recently shown the utility of incorporating strong-motion data (even from soil sites) into the routine analysis of local seismicity, and have also collocated an acoustic array with a broadband seismic station (in collaboration with Southern Methodist University). For the latter experiment, the purpose of collocated seismic and infrasound sensors is to (1) further an understanding of the physics associated with the generation and the propagation of seismic and low-frequency acoustic energy from shallow sources and (2) explore the potential for blast discrimination and improved source location using seismic and infrasonic data in a synergetic way.
NASA Astrophysics Data System (ADS)
Alidoost, F.; Arefi, H.
2017-11-01
Nowadays, Unmanned Aerial System (UAS)-based photogrammetry offers an affordable, fast and effective approach to real-time acquisition of high resolution geospatial information and automatic 3D modelling of objects for numerous applications such as topography mapping, 3D city modelling, orthophoto generation, and cultural heritages preservation. In this paper, the capability of four different state-of-the-art software packages as 3DSurvey, Agisoft Photoscan, Pix4Dmapper Pro and SURE is examined to generate high density point cloud as well as a Digital Surface Model (DSM) over a historical site. The main steps of this study are including: image acquisition, point cloud generation, and accuracy assessment. The overlapping images are first captured using a quadcopter and next are processed by different software to generate point clouds and DSMs. In order to evaluate the accuracy and quality of point clouds and DSMs, both visual and geometric assessments are carry out and the comparison results are reported.
Quality Assurance Testing of Version 1.3 of U.S. EPA Benchmark Dose Software (Presentation)
EPA benchmark dose software (BMDS) issued to evaluate chemical dose-response data in support of Agency risk assessments, and must therefore be dependable. Quality assurance testing methods developed for BMDS were designed to assess model dependability with respect to curve-fitt...
Four Pillars for Improving the Quality of Safety-Critical Software-Reliant Systems
2013-04-01
Studies of safety-critical software-reliant systems developed using the current practices of build-then-test show that requirements and architecture ... design defects make up approximately 70% of all defects, many system level related to operational quality attributes, and 80% of these defects are
Model-Driven Development of Interactive Multimedia Applications with MML
NASA Astrophysics Data System (ADS)
Pleuss, Andreas; Hussmann, Heinrich
There is an increasing demand for high-quality interactive applications which combine complex application logic with a sophisticated user interface, making use of individual media objects like graphics, animations, 3D graphics, audio or video. Their development is still challenging as it requires the integration of software design, user interface design, and media design.
Software Innovations: The Influence of Quality, Diversity and Structure of Network Ties
ERIC Educational Resources Information Center
Singh, Harpeet
2010-01-01
There is high uncertainty associated with the outcomes of Information Technology (IT) investments and innovations. In such environments, IT actors (firm and individuals) are also unsure about their actions and preferences. The social relationships of these actors create substantial value for these actors in multiple ways (e.g. providing social…
Benchmarking heart rate variability toolboxes.
Vest, Adriana N; Li, Qiao; Liu, Chengyu; Nemati, Shamim; Shah, Amit; Clifford, Gari D
Heart rate variability (HRV) metrics hold promise as potential indicators for autonomic function, prediction of adverse cardiovascular outcomes, psychophysiological status, and general wellness. Although the investigation of HRV has been prevalent for several decades, the methods used for preprocessing, windowing, and choosing appropriate parameters lack consensus among academic and clinical investigators. A comprehensive and open-source modular program is presented for calculating HRV implemented in Matlab with evidence-based algorithms and output formats. We compare our software with another widely used HRV toolbox written in C and available through PhysioNet.org. Our findings show substantially similar results when using high quality electrocardiograms (ECG) free from arrhythmias. Our software shows equivalent performance alongside an established predecessor and includes validated tools for performing preprocessing, signal quality, and arrhythmia detection to help provide standardization and repeatability in the field, leading to fewer errors in the presence of noise or arrhythmias. Copyright © 2017 Elsevier Inc. All rights reserved.
Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y
2016-02-01
Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.
PFLOTRAN Verification: Development of a Testing Suite to Ensure Software Quality
NASA Astrophysics Data System (ADS)
Hammond, G. E.; Frederick, J. M.
2016-12-01
In scientific computing, code verification ensures the reliability and numerical accuracy of a model simulation by comparing the simulation results to experimental data or known analytical solutions. The model is typically defined by a set of partial differential equations with initial and boundary conditions, and verification ensures whether the mathematical model is solved correctly by the software. Code verification is especially important if the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment [Oberkampf and Trucano (2007)]. Justified confidence in a particular computational tool requires clarity in the exercised physics and transparency in its verification process with proper documentation. We present a quality assurance (QA) testing suite developed by Sandia National Laboratories that performs code verification for PFLOTRAN, an open source, massively-parallel subsurface simulator. PFLOTRAN solves systems of generally nonlinear partial differential equations describing multiphase, multicomponent and multiscale reactive flow and transport processes in porous media. PFLOTRAN's QA test suite compares the numerical solutions of benchmark problems in heat and mass transport against known, closed-form, analytical solutions, including documentation of the exercised physical process models implemented in each PFLOTRAN benchmark simulation. The QA test suite development strives to follow the recommendations given by Oberkampf and Trucano (2007), which describes four essential elements in high-quality verification benchmark construction: (1) conceptual description, (2) mathematical description, (3) accuracy assessment, and (4) additional documentation and user information. Several QA tests within the suite will be presented, including details of the benchmark problems and their closed-form analytical solutions, implementation of benchmark problems in PFLOTRAN simulations, and the criteria used to assess PFLOTRAN's performance in the code verification procedure. References Oberkampf, W. L., and T. G. Trucano (2007), Verification and Validation Benchmarks, SAND2007-0853, 67 pgs., Sandia National Laboratories, Albuquerque, NM.
NASA Astrophysics Data System (ADS)
McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.
2017-10-01
Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.
Designing Educational Software for Tomorrow.
ERIC Educational Resources Information Center
Harvey, Wayne
Designed to address the management and use of computer software in education and training, this paper explores both good and poor software design, calling for improvements in the quality of educational software by attending to design considerations that are based on general principles of learning rather than specific educational objectives. This…
On Quality and Measures in Software Engineering
ERIC Educational Resources Information Center
Bucur, Ion I.
2006-01-01
Complexity measures are mainly used to estimate vital information about reliability and maintainability of software systems from regular analysis of the source code. Such measures also provide constant feedback during a software project to assist the control of the development procedure. There exist several models to classify a software product's…
ClassCompass: A Software Design Mentoring System
ERIC Educational Resources Information Center
Coelho, Wesley; Murphy, Gail
2007-01-01
Becoming a quality software developer requires practice under the guidance of an expert mentor. Unfortunately, in most academic environments, there are not enough experts to provide any significant design mentoring for software engineering students. To address this problem, we present a collaborative software design tool intended to maximize an…
Software Assurance: Five Essential Considerations for Acquisition Officials
2007-05-01
May 2007 www.stsc.hill.af.mil 17 2 • address security concerns in the software development life cycle ( SDLC )? • Are there formal software quality...What threat modeling process, if any, is used when designing the software ? What analysis, design, and construction tools are used by your software design...the-shelf (COTS), government off-the-shelf (GOTS), open- source, embedded, and legacy software . Attackers exploit unintentional vulnerabil- ities or
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Lau, Kristen C.; Schiabel, Homero; Maidment, D. A.
2015-03-01
Routine performance of basic test procedures and dose measurements are essential for assuring high quality of mammograms. International guidelines recommend that breast care providers ascertain that mammography systems produce a constant high quality image, using as low a radiation dose as is reasonably achievable. The main purpose of this research is to develop a framework to monitor radiation dose and image quality in a mixed breast screening and diagnostic imaging environment using an automated tracking system. This study presents a module of this framework, consisting of a computerized system to measure the image quality of the American College of Radiology mammography accreditation phantom. The methods developed combine correlation approaches, matched filters, and data mining techniques. These methods have been used to analyze radiological images of the accreditation phantom. The classification of structures of interest is based upon reports produced by four trained readers. As previously reported, human observers demonstrate great variation in their analysis due to the subjectivity of human visual inspection. The software tool was trained with three sets of 60 phantom images in order to generate decision trees using the software WEKA (Waikato Environment for Knowledge Analysis). When tested with 240 images during the classification step, the tool correctly classified 88%, 99%, and 98%, of fibers, speck groups and masses, respectively. The variation between the computer classification and human reading was comparable to the variation between human readers. This computerized system not only automates the quality control procedure in mammography, but also decreases the subjectivity in the expert evaluation of the phantom images.
Lee, JuneHyuck; Noh, Sang Do; Kim, Hyun-Jung; Kang, Yong-Shin
2018-05-04
The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS) perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT), artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry.
Continuous integration and quality control for scientific software
NASA Astrophysics Data System (ADS)
Neidhardt, A.; Ettl, M.; Brisken, W.; Dassing, R.
2013-08-01
Modern software has to be stable, portable, fast and reliable. This is going to be also more and more important for scientific software. But this requires a sophisticated way to inspect, check and evaluate the quality of source code with a suitable, automated infrastructure. A centralized server with a software repository and a version control system is one essential part, to manage the code basis and to control the different development versions. While each project can be compiled separately, the whole code basis can also be compiled with one central “Makefile”. This is used to create automated, nightly builds. Additionally all sources are inspected automatically with static code analysis and inspection tools, which check well-none error situations, memory and resource leaks, performance issues, or style issues. In combination with an automatic documentation generator it is possible to create the developer documentation directly from the code and the inline comments. All reports and generated information are presented as HTML page on a Web server. Because this environment increased the stability and quality of the software of the Geodetic Observatory Wettzell tremendously, it is now also available for scientific communities. One regular customer is already the developer group of the DiFX software correlator project.
Gabard-Durnam, Laurel J; Mendez Leal, Adriana S; Wilkinson, Carol L; Levin, April R
2018-01-01
Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe.
Gabard-Durnam, Laurel J.; Mendez Leal, Adriana S.; Wilkinson, Carol L.; Levin, April R.
2018-01-01
Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe. PMID:29535597
NASA Technical Reports Server (NTRS)
Orr, James K.; Peltier, Daryl
2010-01-01
Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.
Using a web-based survey tool to undertake a Delphi study: application for nurse education research.
Gill, Fenella J; Leslie, Gavin D; Grech, Carol; Latour, Jos M
2013-11-01
The Internet is increasingly being used as a data collection medium to access research participants. This paper reports on the experience and value of using web-survey software to conduct an eDelphi study to develop Australian critical care course graduate practice standards. The eDelphi technique used involved the iterative process of administering three rounds of surveys to a national expert panel. The survey was developed online using SurveyMonkey. Panel members responded to statements using one rating scale for round one and two scales for rounds two and three. Text boxes for panel comments were provided. For each round, the SurveyMonkey's email tool was used to distribute an individualized email invitation containing the survey web link. The distribution of panel responses, individual responses and a summary of comments were emailed to panel members. Stacked bar charts representing the distribution of responses were generated using the SurveyMonkey software. Panel response rates remained greater than 85% over all rounds. An online survey provided numerous advantages over traditional survey approaches including high quality data collection, ease and speed of survey administration, direct communication with the panel and rapid collation of feedback allowing data collection to be undertaken in 12 weeks. Only minor challenges were experienced using the technology. Ethical issues, specific to using the Internet to conduct research and external hosting of web-based software, lacked formal guidance. High response rates and an increased level of data quality were achieved in this study using web-survey software and the process was efficient and user-friendly. However, when considering online survey software, it is important to match the research design with the computer capabilities of participants and recognize that ethical review guidelines and processes have not yet kept pace with online research practices. Copyright © 2013 Elsevier Ltd. All rights reserved.
3D Visualization for Phoenix Mars Lander Science Operations
NASA Technical Reports Server (NTRS)
Edwards, Laurence; Keely, Leslie; Lees, David; Stoker, Carol
2012-01-01
Planetary surface exploration missions present considerable operational challenges in the form of substantial communication delays, limited communication windows, and limited communication bandwidth. A 3D visualization software was developed and delivered to the 2008 Phoenix Mars Lander (PML) mission. The components of the system include an interactive 3D visualization environment called Mercator, terrain reconstruction software called the Ames Stereo Pipeline, and a server providing distributed access to terrain models. The software was successfully utilized during the mission for science analysis, site understanding, and science operations activity planning. A terrain server was implemented that provided distribution of terrain models from a central repository to clients running the Mercator software. The Ames Stereo Pipeline generates accurate, high-resolution, texture-mapped, 3D terrain models from stereo image pairs. These terrain models can then be visualized within the Mercator environment. The central cross-cutting goal for these tools is to provide an easy-to-use, high-quality, full-featured visualization environment that enhances the mission science team s ability to develop low-risk productive science activity plans. In addition, for the Mercator and Viz visualization environments, extensibility and adaptability to different missions and application areas are key design goals.
An Exploration of Software-Based GNSS Signal Processing at Multiple Frequencies
NASA Astrophysics Data System (ADS)
Pasqual Paul, Manuel; Elosegui, Pedro; Lind, Frank; Vazquez, Antonio; Pankratius, Victor
2017-01-01
The Global Navigation Satellite System (GNSS; i.e., GPS, GLONASS, Galileo, and other constellations) has recently grown into numerous areas that go far beyond the traditional scope in navigation. In the geosciences, for example, high-precision GPS has become a powerful tool for a myriad of geophysical applications such as in geodynamics, seismology, paleoclimate, cryosphere, and remote sensing of the atmosphere. Positioning with millimeter-level accuracy can be achieved through carrier-phase-based, multi-frequency signal processing, which mitigates various biases and error sources such as those arising from ionospheric effects. Today, however, most receivers with multi-frequency capabilities are highly specialized hardware receiving systems with proprietary and closed designs, limited interfaces, and significant acquisition costs. This work explores alternatives that are entirely software-based, using Software-Defined Radio (SDR) receivers as a way to digitize the entire spectrum of interest. It presents an overview of existing open-source frameworks and outlines the next steps towards converting GPS software receivers from single-frequency to dual-frequency, geodetic-quality systems. In the future, this development will lead to a more flexible multi-constellation GNSS processing architecture that can be easily reused in different contexts, as well as to further miniaturization of receivers.
A tool to include gamma analysis software into a quality assurance program.
Agnew, Christina E; McGarry, Conor K
2016-03-01
To provide a tool to enable gamma analysis software algorithms to be included in a quality assurance (QA) program. Four image sets were created comprising two geometric images to independently test the distance to agreement (DTA) and dose difference (DD) elements of the gamma algorithm, a clinical step and shoot IMRT field and a clinical VMAT arc. The images were analysed using global and local gamma analysis with 2 in-house and 8 commercially available software encompassing 15 software versions. The effect of image resolution on gamma pass rates was also investigated. All but one software accurately calculated the gamma passing rate for the geometric images. Variation in global gamma passing rates of 1% at 3%/3mm and over 2% at 1%/1mm was measured between software and software versions with analysis of appropriately sampled images. This study provides a suite of test images and the gamma pass rates achieved for a selection of commercially available software. This image suite will enable validation of gamma analysis software within a QA program and provide a frame of reference by which to compare results reported in the literature from various manufacturers and software versions. Copyright © 2015. Published by Elsevier Ireland Ltd.
Towards a Better Understanding of CMMI and Agile Integration - Multiple Case Study of Four Companies
NASA Astrophysics Data System (ADS)
Pikkarainen, Minna
The amount of software is increasing in the different domains in Europe. This provides the industries in smaller countries good opportunities to work in the international markets. Success in the global markets however demands the rapid production of high quality, error free software. Both CMMI and agile methods seem to provide a ready solution for quality and lead time improvements. There is not, however, much empirical evidence available either about 1) how the integration of these two aspects can be done in practice or 2) what it actually demands from assessors and software process improvement groups. The goal of this paper is to increase the understanding of CMMI and agile integration, in particular, focusing on the research question: how to use ‘lightweight’ style of CMMI assessments in agile contexts. This is done via four case studies in which assessments were conducted using the goals of CMMI integrated project management and collaboration and coordination with relevant stakeholder process areas and practices from XP and Scrum. The study shows that the use of agile practices may support the fulfilment of the goals of CMMI process areas but there are still many challenges for the agile teams to be solved within the continuous improvement programs. It also identifies practical advices to the assessors and improvement groups to take into consideration when conducting assessment in the context of agile software development.
Torfeh, Tarraf; Hammoud, Rabih; McGarry, Maeve; Al-Hammadi, Noora; Perkins, Gregory
2015-09-01
To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. A purpose built phantom was developed consisting of 357 rods (6mm in diameter) of polymethyl-methacrylat separated by 20mm intervals, providing a three dimensional array of control points at known spatial locations covering a large field of view up to a diameter of 420mm. An in-house software module was developed to allow automatic geometric distortion assessment. This software module was validated against a virtual dataset of the phantom that reproduced the exact geometry of the physical phantom, but with known translational and rotational displacements and warping. For validation experiments, clinical MRI sequences were acquired with and without the application of a commercial 3D distortion correction algorithm (Gradwarp™). The software module was used to characterize and assess system-related geometric distortion in the sequences relative to a benchmark CT dataset, and the efficacy of the vendor geometric distortion correction algorithms (GDC) was also assessed. Results issued from the validation of the software against virtual images demonstrate the algorithm's ability to accurately calculate geometric distortion with sub-pixel precision by the extraction of rods and quantization of displacements. Geometric distortion was assessed for the typical sequences used in radiotherapy applications and over a clinically relevant 420mm field of view (FOV). As expected and towards the edges of the field of view (FOV), distortion increased with increasing FOV. For all assessed sequences, the vendor GDC was able to reduce the mean distortion to below 1mm over a field of view of 5, 10, 15 and 20cm radius respectively. Results issued from the application of the developed phantoms and algorithms demonstrate a high level of precision. The results indicate that this platform represents an important, robust and objective tool to perform routine quality assurance of MR-guided therapeutic applications, where spatial accuracy is paramount. Copyright © 2015 Elsevier Inc. All rights reserved.
IMPROVING (SOFTWARE) PATENT QUALITY THROUGH THE ADMINISTRATIVE PROCESS
Rai, Arti K.
2014-01-01
The available evidence indicates that patent quality, particularly in the area of software, needs improvement. This Article argues that even an agency as institutionally constrained as the U.S. Patent and Trademark Office (“PTO”) could implement a portfolio of pragmatic, cost-effective quality improvement strategies. The argument in favor of these strategies draws upon not only legal theory and doctrine but also new data from a PTO software examination unit with relatively strict practices. Strategies that resolve around Section 112 of the patent statute could usefully be deployed at the initial examination stage. Other strategies could be deployed within the new post-issuance procedures available to the agency under the America Invents Act. Notably, although the strategies the Article discusses have the virtue of being neutral as to technology, they are likely to have a very significant practical impact in the area of software. PMID:25221346
QuickEval: a web application for psychometric scaling experiments
NASA Astrophysics Data System (ADS)
Van Ngo, Khai; Storvik, Jehans J.; Dokkeberg, Christopher A.; Farup, Ivar; Pedersen, Marius
2015-01-01
QuickEval is a web application for carrying out psychometric scaling experiments. It offers the possibility of running controlled experiments in a laboratory, or large scale experiment over the web for people all over the world. It is a unique one of a kind web application, and it is a software needed in the image quality field. It is also, to the best of knowledge, the first software that supports the three most common scaling methods; paired comparison, rank order, and category judgement. It is also the first software to support rank order. Hopefully, a side effect of this newly created software is that it will lower the threshold to perform psychometric experiments, improve the quality of the experiments being carried out, make it easier to reproduce experiments, and increase research on image quality both in academia and industry. The web application is available at www.colourlab.no/quickeval.
IMPROVING (SOFTWARE) PATENT QUALITY THROUGH THE ADMINISTRATIVE PROCESS.
Rai, Arti K
2013-11-24
The available evidence indicates that patent quality, particularly in the area of software, needs improvement. This Article argues that even an agency as institutionally constrained as the U.S. Patent and Trademark Office ("PTO") could implement a portfolio of pragmatic, cost-effective quality improvement strategies. The argument in favor of these strategies draws upon not only legal theory and doctrine but also new data from a PTO software examination unit with relatively strict practices. Strategies that resolve around Section 112 of the patent statute could usefully be deployed at the initial examination stage. Other strategies could be deployed within the new post-issuance procedures available to the agency under the America Invents Act. Notably, although the strategies the Article discusses have the virtue of being neutral as to technology, they are likely to have a very significant practical impact in the area of software.
Ethical choice in the medical applications of information theory.
Haig, Scott V
2010-10-01
Alongside advances in medical information technology (IT), there is mounting physician and patient dissatisfaction with present-day clinical practice. The effect of introducing increasingly complex medical IT on the ethical dimension of the clinical physician's primary task (identified as direct patient care) can be scrutinized through analysis of the EMR software platform. We therefore (1) identify IT changes burdensome to the clinician in performing patient care and which therefore lower quality of care; and (2) suggest methods for clinicians to maintain high quality patient care as IT demands increase. Elemental relationships from information theory and physical chemistry are applied to the profit-generating creation and flow of medical information between patients, physicians, administrators, suppliers, and insurers. Ethical implications for patient care and the doctor-patient relationship are drawn in the light of these relationships. WHERE ARE WE NOW?: Little has been accomplished, or even discussed, regarding limiting healthcare IT growth. Quality of patient care is expected to suffer unless physicians carefully scrutinize, refine and occasionally reject portions of the increasing healthcare IT burden being placed upon them. WHERE DO WE NEED TO GO?: Better medicine, simply understood as more effective prevention and treatment of musculoskeletal disease, is our professional goal. We need to establish mechanisms whereby we can limit, control or even reverse IT changes that hinder this goal. Clinicians must confront the negative impact many healthcare IT changes have on patient care. HOW DO WE GET THERE?: Suggestions for maintaining high standards of practice in the face of the new IT burden include: (1) Increasing IT time-awareness. Clinicians should examine actual time spent in clinical versus computer-based activity and implement changes if that ratio is too high. (2) Increasing IT goal awareness. (3) Examine the software creating a medical record to see how much of what it records is there for financial, as opposed to medical reasons. Is the software helping my patient or someone else's bottom line? Is it for talking to colleagues about sick people or to insurance companies?
Standardized development of computer software. Part 2: Standards
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1978-01-01
This monograph contains standards for software development and engineering. The book sets forth rules for design, specification, coding, testing, documentation, and quality assurance audits of software; it also contains detailed outlines for the documentation to be produced.
Harnessing ISO/IEC 12207 to Examine the Extent of SPI Activity in an Organisation
NASA Astrophysics Data System (ADS)
Clarke, Paul; O'Connor, Rory
The quality of the software development process directly affects the quality of the software product. To be successful, software development organisations must respond to changes in technology and business circumstances, and therefore software process improvement (SPI) is required. SPI activity relates to any modification that is performed to the software process in order to improve an aspect of the process. Although multiple process assessments could be employed to examine SPI activity, they present an inefficient tool for such an examination. This paper presents an overview of a new survey-based resource that utilises the process reference model in ISO/IEC 12207 in order to expressly and directly determine the level of SPI activity in a software development organisation. This survey instrument can be used by practitioners, auditors and researchers who are interested in determining the extent of SPI activity in an organisation.
Software for Optimizing Quality Assurance of Other Software
NASA Technical Reports Server (NTRS)
Feather, Martin; Cornford, Steven; Menzies, Tim
2004-01-01
Software assurance is the planned and systematic set of activities that ensures that software processes and products conform to requirements, standards, and procedures. Examples of such activities are the following: code inspections, unit tests, design reviews, performance analyses, construction of traceability matrices, etc. In practice, software development projects have only limited resources (e.g., schedule, budget, and availability of personnel) to cover the entire development effort, of which assurance is but a part. Projects must therefore select judiciously from among the possible assurance activities. At its heart, this can be viewed as an optimization problem; namely, to determine the allocation of limited resources (time, money, and personnel) to minimize risk or, alternatively, to minimize the resources needed to reduce risk to an acceptable level. The end result of the work reported here is a means to optimize quality-assurance processes used in developing software.
Developing high-quality educational software.
Johnson, Lynn A; Schleyer, Titus K L
2003-11-01
The development of effective educational software requires a systematic process executed by a skilled development team. This article describes the core skills required of the development team members for the six phases of successful educational software development. During analysis, the foundation of product development is laid including defining the audience and program goals, determining hardware and software constraints, identifying content resources, and developing management tools. The design phase creates the specifications that describe the user interface, the sequence of events, and the details of the content to be displayed. During development, the pieces of the educational program are assembled. Graphics and other media are created, video and audio scripts written and recorded, the program code created, and support documentation produced. Extensive testing by the development team (alpha testing) and with students (beta testing) is conducted. Carefully planned implementation is most likely to result in a flawless delivery of the educational software and maintenance ensures up-to-date content and software. Due to the importance of the sixth phase, evaluation, we have written a companion article on it that follows this one. The development of a CD-ROM product is described including the development team, a detailed description of the development phases, and the lessons learned from the project.
High-quality and small-capacity e-learning video featuring lecturer-superimposing PC screen images
NASA Astrophysics Data System (ADS)
Nomura, Yoshihiko; Murakami, Michinobu; Sakamoto, Ryota; Sugiura, Tokuhiro; Matsui, Hirokazu; Kato, Norihiko
2006-10-01
Information processing and communication technology are progressing quickly, and are prevailing throughout various technological fields. Therefore, the development of such technology should respond to the needs for improvement of quality in the e-learning education system. The authors propose a new video-image compression processing system that ingeniously employs the features of the lecturing scene. While dynamic lecturing scene is shot by a digital video camera, screen images are electronically stored by a PC screen image capturing software in relatively long period at a practical class. Then, a lecturer and a lecture stick are extracted from the digital video images by pattern recognition techniques, and the extracted images are superimposed on the appropriate PC screen images by off-line processing. Thus, we have succeeded to create a high-quality and small-capacity (HQ/SC) video-on-demand educational content featuring the advantages: the high quality of image sharpness, the small electronic file capacity, and the realistic lecturer motion.
Espino, Jeremy U; Wagner, M; Szczepaniak, C; Tsui, F C; Su, H; Olszewski, R; Liu, Z; Chapman, W; Zeng, X; Ma, L; Lu, Z; Dara, J
2004-09-24
Computer-based outbreak and disease surveillance requires high-quality software that is well-supported and affordable. Developing software in an open-source framework, which entails free distribution and use of software and continuous, community-based software development, can produce software with such characteristics, and can do so rapidly. The objective of the Real-Time Outbreak and Disease Surveillance (RODS) Open Source Project is to accelerate the deployment of computer-based outbreak and disease surveillance systems by writing software and catalyzing the formation of a community of users, developers, consultants, and scientists who support its use. The University of Pittsburgh seeded the Open Source Project by releasing the RODS software under the GNU General Public License. An infrastructure was created, consisting of a website, mailing lists for developers and users, designated software developers, and shared code-development tools. These resources are intended to encourage growth of the Open Source Project community. Progress is measured by assessing website usage, number of software downloads, number of inquiries, number of system deployments, and number of new features or modules added to the code base. During September--November 2003, users generated 5,370 page views of the project website, 59 software downloads, 20 inquiries, one new deployment, and addition of four features. Thus far, health departments and companies have been more interested in using the software as is than in customizing or developing new features. The RODS laboratory anticipates that after initial installation has been completed, health departments and companies will begin to customize the software and contribute their enhancements to the public code base.
Integrated thermal disturbance analysis of optical system of astronomical telescope
NASA Astrophysics Data System (ADS)
Yang, Dehua; Jiang, Zibo; Li, Xinnan
2008-07-01
During operation, astronomical telescope will undergo thermal disturbance, especially more serious in solar telescope, which may cause degradation of image quality. As drives careful thermal load investigation and measure applied to assess its effect on final image quality during design phase. Integrated modeling analysis is boosting the process to find comprehensive optimum design scheme by software simulation. In this paper, we focus on the Finite Element Analysis (FEA) software-ANSYS-for thermal disturbance analysis and the optical design software-ZEMAX-for optical system design. The integrated model based on ANSYS and ZEMAX is briefed in the first from an overview of point. Afterwards, we discuss the establishment of thermal model. Complete power series polynomial with spatial coordinates is introduced to present temperature field analytically. We also borrow linear interpolation technique derived from shape function in finite element theory to interface the thermal model and structural model and further to apply the temperatures onto structural model nodes. Thereby, the thermal loads are transferred with as high fidelity as possible. Data interface and communication between the two softwares are discussed mainly on mirror surfaces and hence on the optical figure representation and transformation. We compare and comment the two different methods, Zernike polynomials and power series expansion, for representing and transforming deformed optical surface to ZEMAX. Additionally, these methods applied to surface with non-circular aperture are discussed. At the end, an optical telescope with parabolic primary mirror of 900 mm in diameter is analyzed to illustrate the above discussion. Finite Element Model with most interested parts of the telescope is generated in ANSYS with necessary structural simplification and equivalence. Thermal analysis is performed and the resulted positions and figures of the optics are to be retrieved and transferred to ZEMAX, and thus final image quality is evaluated with thermal disturbance.
Data management in clinical research: Synthesizing stakeholder perspectives.
Johnson, Stephen B; Farach, Frank J; Pelphrey, Kevin; Rozenblit, Leon
2016-04-01
This study assesses data management needs in clinical research from the perspectives of researchers, software analysts and developers. This is a mixed-methods study that employs sublanguage analysis in an innovative manner to link the assessments. We performed content analysis using sublanguage theory on transcribed interviews conducted with researchers at four universities. A business analyst independently extracted potential software features from the transcriptions, which were translated into the sublanguage. This common sublanguage was then used to create survey questions for researchers, analysts and developers about the desirability and difficulty of features. Results were synthesized using the common sublanguage to compare stakeholder perceptions with the original content analysis. Individual researchers exhibited significant diversity of perspectives that did not correlate by role or site. Researchers had mixed feelings about their technologies, and sought improvements in integration, interoperability and interaction as well as engaging with study participants. Researchers and analysts agreed that data integration has higher desirability and mobile technology has lower desirability but disagreed on the desirability of data validation rules. Developers agreed that data integration and validation are the most difficult to implement. Researchers perceive tasks related to study execution, analysis and quality control as highly strategic, in contrast with tactical tasks related to data manipulation. Researchers have only partial technologic support for analysis and quality control, and poor support for study execution. Software for data integration and validation appears critical to support clinical research, but may be expensive to implement. Features to support study workflow, collaboration and engagement have been underappreciated, but may prove to be easy successes. Software developers should consider the strategic goals of researchers with regard to the overall coordination of research projects and teams, workflow connecting data collection with analysis and processes for improving data quality. Copyright © 2016 Elsevier Inc. All rights reserved.
Installé, Arnaud Jf; Van den Bosch, Thierry; De Moor, Bart; Timmerman, Dirk
2014-10-20
Using machine-learning techniques, clinical diagnostic model research extracts diagnostic models from patient data. Traditionally, patient data are often collected using electronic Case Report Form (eCRF) systems, while mathematical software is used for analyzing these data using machine-learning techniques. Due to the lack of integration between eCRF systems and mathematical software, extracting diagnostic models is a complex, error-prone process. Moreover, due to the complexity of this process, it is usually only performed once, after a predetermined number of data points have been collected, without insight into the predictive performance of the resulting models. The objective of the study of Clinical Data Miner (CDM) software framework is to offer an eCRF system with integrated data preprocessing and machine-learning libraries, improving efficiency of the clinical diagnostic model research workflow, and to enable optimization of patient inclusion numbers through study performance monitoring. The CDM software framework was developed using a test-driven development (TDD) approach, to ensure high software quality. Architecturally, CDM's design is split over a number of modules, to ensure future extendability. The TDD approach has enabled us to deliver high software quality. CDM's eCRF Web interface is in active use by the studies of the International Endometrial Tumor Analysis consortium, with over 4000 enrolled patients, and more studies planned. Additionally, a derived user interface has been used in six separate interrater agreement studies. CDM's integrated data preprocessing and machine-learning libraries simplify some otherwise manual and error-prone steps in the clinical diagnostic model research workflow. Furthermore, CDM's libraries provide study coordinators with a method to monitor a study's predictive performance as patient inclusions increase. To our knowledge, CDM is the only eCRF system integrating data preprocessing and machine-learning libraries. This integration improves the efficiency of the clinical diagnostic model research workflow. Moreover, by simplifying the generation of learning curves, CDM enables study coordinators to assess more accurately when data collection can be terminated, resulting in better models or lower patient recruitment costs.
NASA Astrophysics Data System (ADS)
Hameetman, G. J.; Dekker, G. J.
1993-11-01
The Italian satellite (with a large Dutch contribution) SAX is a scientific satellite which has the mission to study roentgen sources. One main requirement for the Attitude and Orbit Control Subsystem (AOCS) is to achieve and maintain a stable pointing accuracy with a limit cycle of less than 90 arcsec during pointings of maximal 28 hours. The main SAX instrument, the Narrow Field Instrument, is highly sensitive to (indirect) radiation coming from the Sun. This sensitivity leads to another main requirement that under no circumstances the safe attitude domain may be left. The paper describes the application software in relation with the overall SAX AOCS subsystem, the CASE tools that have been used during the development, some advantages and disadvantages of the use of these tools, the measures taken to meet the more or less conflicting requirements of reliability and flexibility, and the lessons learned during development. The quality of the approach to the development has proven the (separately executed) hardware/software integration tests. During these tests, a neglectible number of software errors has been detected in the application software.
Khoshgoftaar, T M; Allen, E B; Hudepohl, J P; Aud, S J
1997-01-01
Society relies on telecommunications to such an extent that telecommunications software must have high reliability. Enhanced measurement for early risk assessment of latent defects (EMERALD) is a joint project of Nortel and Bell Canada for improving the reliability of telecommunications software products. This paper reports a case study of neural-network modeling techniques developed for the EMERALD system. The resulting neural network is currently in the prototype testing phase at Nortel. Neural-network models can be used to identify fault-prone modules for extra attention early in development, and thus reduce the risk of operational problems with those modules. We modeled a subset of modules representing over seven million lines of code from a very large telecommunications software system. The set consisted of those modules reused with changes from the previous release. The dependent variable was membership in the class of fault-prone modules. The independent variables were principal components of nine measures of software design attributes. We compared the neural-network model with a nonparametric discriminant model and found the neural-network model had better predictive accuracy.
Chung, Beom Sun; Chung, Min Suk; Shin, Byeong Seok; Kwon, Koojoo
2018-02-19
The hand anatomy, including the complicated hand muscles, can be grasped by using computer-assisted learning tools with high quality two-dimensional images and three-dimensional models. The purpose of this study was to present up-to-date software tools that promote learning of stereoscopic morphology of the hand. On the basis of horizontal sectioned images and outlined images of a male cadaver, vertical planes, volume models, and surface models were elaborated. Software to browse pairs of the sectioned and outlined images in orthogonal planes and software to peel and rotate the volume models, as well as a portable document format (PDF) file to select and rotate the surface models, were produced. All of the software tools were downloadable free of charge and usable off-line. The three types of tools for viewing multiple aspects of the hand could be adequately employed according to individual needs. These new tools involving the realistic images of a cadaver and the diverse functions are expected to improve comprehensive knowledge of the hand shape. © 2018 The Korean Academy of Medical Sciences.
2018-01-01
Background The hand anatomy, including the complicated hand muscles, can be grasped by using computer-assisted learning tools with high quality two-dimensional images and three-dimensional models. The purpose of this study was to present up-to-date software tools that promote learning of stereoscopic morphology of the hand. Methods On the basis of horizontal sectioned images and outlined images of a male cadaver, vertical planes, volume models, and surface models were elaborated. Software to browse pairs of the sectioned and outlined images in orthogonal planes and software to peel and rotate the volume models, as well as a portable document format (PDF) file to select and rotate the surface models, were produced. Results All of the software tools were downloadable free of charge and usable off-line. The three types of tools for viewing multiple aspects of the hand could be adequately employed according to individual needs. Conclusion These new tools involving the realistic images of a cadaver and the diverse functions are expected to improve comprehensive knowledge of the hand shape. PMID:29441756
NASA Astrophysics Data System (ADS)
Marculescu, Bogdan; Feldt, Robert; Torkar, Richard; Green, Lars-Goran; Liljegren, Thomas; Hult, Erika
2011-08-01
Verification and validation is an important part of software development and accounts for significant amounts of the costs associated with such a project. For developers of life or mission critical systems, such as software being developed for space applications, a balance must be reached between ensuring the quality of the system by extensive and rigorous testing and reducing costs and allowing the company to compete.Ensuring the quality of any system starts with a quality development process. To evaluate both the software development process and the product itself, measurements are needed. A balance must be then struck between ensuring the best possible quality of both process and product on the one hand, and reducing the cost of performing requirements on the other.A number of measurements have already been defined and are being used. For some of these, data collection can be automated as well, further lowering costs associated with implementing them. In practice, however, there may be situations where existing measurements are unsuitable for a variety of reasons.This paper describes a framework for creating low cost, flexible measurements in areas where initial information is scarce. The framework, called The Measurements Exploration Framework, is aimed in particular at the Space Software development industry and was developed is such an environment.
Nakazato, Takeru; Bono, Hidemasa
2017-01-01
Abstract It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. PMID:28449062
A design procedure for the handling qualities optimization of the X-29A aircraft
NASA Technical Reports Server (NTRS)
Bosworth, John T.; Cox, Timothy H.
1989-01-01
A design technique for handling qualities improvement was developed for the X-29A aircraft. As with any new aircraft, the X-29A control law designers were presented with a relatively high degree of uncertainty in their mathematical models. The presence of uncertainties, and the high level of static instability of the X-29A caused the control law designers to stress stability and robustness over handling qualities. During flight test, the mathematical models of the vehicle were validated or corrected to match the vehicle dynamic behavior. The updated models were then used to fine tune the control system to provide fighter-like handling characteristics. A design methodology was developed which works within the existing control system architecture to provide improved handling qualities and acceptable stability with a minimum of cost in both implementation as well as software verification and validation.
Ayling, Pete; Hill, Robert; Jassam, Nuthar; Kallner, Anders; Khatami, Zahra
2017-11-01
Background A logical consequence of the introduction of robotics and high-capacity analysers has seen a consolidation to larger units. This requires new structures and quality systems to ensure that laboratories deliver consistent and comparable results. Methods A spreadsheet program was designed to accommodate results from up to 12 different instruments/laboratories and present IQC data, i.e. Levey-Jennings and Youden plots and comprehensive numerical tables of the performance of each item. Input of data was made possible by a 'data loader' by which IQC data from the individual instruments could be transferred to the spreadsheet program on line. Results A set of real data from laboratories is used to populate the data loader and the networking software program. Examples are present from the analysis of variance components, the Levey-Jennings and Youden plots. Conclusions This report presents a software package that allows the simultaneous management and detailed monitoring of the performance of up to 12 different instruments/laboratories in a fully interactive mode. The system allows a quality manager of networked laboratories to have a continuous updated overview of the performance. This software package has been made available at the ACB website.
Discrepancy Reporting Management System
NASA Technical Reports Server (NTRS)
Cooper, Tonja M.; Lin, James C.; Chatillon, Mark L.
2004-01-01
Discrepancy Reporting Management System (DRMS) is a computer program designed for use in the stations of NASA's Deep Space Network (DSN) to help establish the operational history of equipment items; acquire data on the quality of service provided to DSN customers; enable measurement of service performance; provide early insight into the need to improve processes, procedures, and interfaces; and enable the tracing of a data outage to a change in software or hardware. DRMS is a Web-based software system designed to include a distributed database and replication feature to achieve location-specific autonomy while maintaining a consistent high quality of data. DRMS incorporates commercial Web and database software. DRMS collects, processes, replicates, communicates, and manages information on spacecraft data discrepancies, equipment resets, and physical equipment status, and maintains an internal station log. All discrepancy reports (DRs), Master discrepancy reports (MDRs), and Reset data are replicated to a master server at NASA's Jet Propulsion Laboratory; Master DR data are replicated to all the DSN sites; and Station Logs are internal to each of the DSN sites and are not replicated. Data are validated according to several logical mathematical criteria. Queries can be performed on any combination of data.
NASA Astrophysics Data System (ADS)
Dostálová, Alena; Naeimi, Vahid; Wagner, Wolfgang; Elefante, Stefano; Cao, Senmao; Persson, Henrik
2016-10-01
One of the major advantages of the Sentinel-1 data is its capability to provide very high spatio-temporal coverage allowing the mapping of large areas as well as creation of dense time-series of the Sentinel-1 acquisitions. The SGRT software developed at TU Wien aims at automated processing of Sentinel-1 data for global and regional products. The first step of the processing consists of the Sentinel-1 data geocoding with the help of S1TBX software and their resampling to a common grid. These resampled images serve as an input for the product derivation. Thus, it is very important to select the most reliable processing settings and assess the geocoding uncertainty for both backscatter and projected local incidence angle images. Within this study, selection of Sentinel-1 acquisitions over 3 test areas in Europe were processed manually in the S1TBX software, testing multiple software versions, processing settings and digital elevation models (DEM) and the accuracy of the resulting geocoded images were assessed. Secondly, all available Sentinel-1 data over the areas were processed using selected settings and detailed quality check was performed. Overall, strong influence of the used DEM on the geocoding quality was confirmed with differences up to 80 meters in areas with higher terrain variations. In flat areas, the geocoding accuracy of backscatter images was overall good, with observed shifts between 0 and 30m. Larger systematic shifts were identified in case of projected local incidence angle images. These results encourage the automated processing of large volumes of Sentinel-1 data.
Acoustic Doppler Current Profiler Data Processing System manual [ADCP
Cote, Jessica M.; Hotchkiss, Frances S.; Martini, Marinna A.; Denham, Charles R.; revisions by Ramsey, Andree L.; Ruane, Stephen
2000-01-01
This open-file report describes the data processing software currently in use by the U.S. Geological Survey (USGS), Woods Hole Coastal and Marine Science Center (WHCMSC), to process time series of acoustic Doppler current data obtained by Teledyne RD Instruments Workhorse model ADCPs. The Sediment Transport Instrumentation Group (STG) at the WHCMSC has a long-standing commitment to providing scientists high quality oceanographic data published in a timely manner. To meet this commitment, STG has created this software to aid personnel in processing and reviewing data as well as evaluating hardware for signs of instrument malfunction. The output data format for the data is network Common Data Form (netCDF), which meets USGS publication standards. Typically, ADCP data are recorded in beam coordinates. This conforms to the USGS philosophy to post-process rather than internally process data. By preserving the original data quality indicators as well as the initial data set, data can be evaluated and reprocessed for different types of analyses. Beam coordinate data are desirable for internal and surface wave experiments, for example. All the code in this software package is intended to run using the MATLAB program available from The Mathworks, Inc. As such, it is platform independent and can be adapted by the USGS and others for specialized experiments with non-standard requirements. The software is continuously being updated and revised as improvements are required. The most recent revision may be downloaded from: http://woodshole.er.usgs.gov/operations/stg/Pubs/ADCPtools/adcp_index.htm The USGS makes this software available at the user?s discretion and responsibility.
Semantic Metrics for Analysis of Software
NASA Technical Reports Server (NTRS)
Etzkorn, Letha H.; Cox, Glenn W.; Farrington, Phil; Utley, Dawn R.; Ghalston, Sampson; Stein, Cara
2005-01-01
A recently conceived suite of object-oriented software metrics focus is on semantic aspects of software, in contradistinction to traditional software metrics, which focus on syntactic aspects of software. Semantic metrics represent a more human-oriented view of software than do syntactic metrics. The semantic metrics of a given computer program are calculated by use of the output of a knowledge-based analysis of the program, and are substantially more representative of software quality and more readily comprehensible from a human perspective than are the syntactic metrics.
21 CFR 1271.160 - Establishment and maintenance of a quality program.
Code of Federal Regulations, 2014 CFR
2014-04-01
... perform for management review a quality audit, as defined in § 1271.3(gg), of activities related to core CGTP requirements. (d) Computers. You must validate the performance of computer software for the intended use, and the performance of any changes to that software for the intended use, if you rely upon...
21 CFR 1271.160 - Establishment and maintenance of a quality program.
Code of Federal Regulations, 2012 CFR
2012-04-01
... perform for management review a quality audit, as defined in § 1271.3(gg), of activities related to core CGTP requirements. (d) Computers. You must validate the performance of computer software for the intended use, and the performance of any changes to that software for the intended use, if you rely upon...
21 CFR 1271.160 - Establishment and maintenance of a quality program.
Code of Federal Regulations, 2011 CFR
2011-04-01
... perform for management review a quality audit, as defined in § 1271.3(gg), of activities related to core CGTP requirements. (d) Computers. You must validate the performance of computer software for the intended use, and the performance of any changes to that software for the intended use, if you rely upon...
21 CFR 1271.160 - Establishment and maintenance of a quality program.
Code of Federal Regulations, 2013 CFR
2013-04-01
... perform for management review a quality audit, as defined in § 1271.3(gg), of activities related to core CGTP requirements. (d) Computers. You must validate the performance of computer software for the intended use, and the performance of any changes to that software for the intended use, if you rely upon...
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J.
1998-01-01
Software is becoming increasingly significant in today's critical avionics systems. To achieve safe, reliable software, government regulatory agencies such as the Federal Aviation Administration (FAA) and the Department of Defense mandate the use of certain software development methods. However, little scientific evidence exists to show a correlation between software development methods and product quality. Given this lack of evidence, a series of experiments has been conducted to understand why and how software fails. The Guidance and Control Software (GCS) project is the latest in this series. The GCS project is a case study of the Requirements and Technical Concepts for Aviation RTCA/DO-178B guidelines, Software Considerations in Airborne Systems and Equipment Certification. All civil transport airframe and equipment vendors are expected to comply with these guidelines in building systems to be certified by the FAA for use in commercial aircraft. For the case study, two implementations of a guidance and control application were developed to comply with the DO-178B guidelines for Level A (critical) software. The development included the requirements, design, coding, verification, configuration management, and quality assurance processes. This paper discusses the details of the GCS project and presents the results of the case study.
A Bibliography of the Personal Software Process (PSP) and the Team Software Process (TSP)
2009-10-01
Postmortem.‖ Proceedings of the TSP Symposium (September 2007). http://www.sei.cmu.edu/tspsymposium/ Rickets , Chris; Lindeman, Robert; & Hodgins, Brad... Rickets , Chris A. ―A TSP Software Maintenance Life Cycle.‖ CrossTalk (March 2005). Rozanc, I. & Mahnic, V. ―Teaching Software Quality with Emphasis on PSP
ERIC Educational Resources Information Center
Chen, Chung-Yang; Hong, Ya-Chun; Chen, Pei-Chi
2014-01-01
Software development relies heavily on teamwork; determining how to streamline this collaborative development is an essential training subject in computer and software engineering education. A team process known as the meetings-flow (MF) approach has recently been introduced in software capstone projects in engineering programs at various…
Automatic Rotational Sky Quality Meter (R-SQM) Design and Software for Astronomical Observatories
NASA Astrophysics Data System (ADS)
Dogan, E.; Ozbaldan, E. E.; Shameoni, Niaei M.; Yesilyaprak, C.
2016-12-01
We have presented the new design of Sky Quality Meter (SQM) device that is an automatic rotational model of sky quality meter (R-SQM) carried out by DAG (Eastern Anatolia Observatory) Technical Team. R-SQM is required for determining the long-term changes of sky quality of an astronomical observatory and consists of four SQM devices mounted on a rotating shaft with different angles for scanning all sky. This system is controlled by a Raspberry Pi control card and a step motor with its driver and a special software.
Zhou, Chunshan; Zhang, Chao; Tian, Di; Wang, Ke; Huang, Mingzhi; Liu, Yanbiao
2018-01-02
In order to manage water resources, a software sensor model was designed to estimate water quality using a hybrid fuzzy neural network (FNN) in Guangzhou section of Pearl River, China. The software sensor system was composed of data storage module, fuzzy decision-making module, neural network module and fuzzy reasoning generator module. Fuzzy subtractive clustering was employed to capture the character of model, and optimize network architecture for enhancing network performance. The results indicate that, on basis of available on-line measured variables, the software sensor model can accurately predict water quality according to the relationship between chemical oxygen demand (COD) and dissolved oxygen (DO), pH and NH 4 + -N. Owing to its ability in recognizing time series patterns and non-linear characteristics, the software sensor-based FNN is obviously superior to the traditional neural network model, and its R (correlation coefficient), MAPE (mean absolute percentage error) and RMSE (root mean square error) are 0.8931, 10.9051 and 0.4634, respectively.
Software Formal Inspections Standard
NASA Technical Reports Server (NTRS)
1993-01-01
This Software Formal Inspections Standard (hereinafter referred to as Standard) is applicable to NASA software. This Standard defines the requirements that shall be fulfilled by the software formal inspections process whenever this process is specified for NASA software. The objective of this Standard is to define the requirements for a process that inspects software products to detect and eliminate defects as early as possible in the software life cycle. The process also provides for the collection and analysis of inspection data to improve the inspection process as well as the quality of the software.
Guidance and Control Software,
1980-05-01
commitments of function, cost, and schedule . The phrase "software engineering" was intended to contrast with the phrase "computer science" the latter aims...the software problems of cost, delivery schedule , and quality were gradually being recognized at the highest management levels. Thus, in a project... schedule dates. Although the analysis of software problems indicated that the entire software development process (figure 1) needed new methods, only
Valjevac, Salih; Ridjanovic, Zoran; Masic, Izet
2009-01-01
CONFLICT OF INTEREST: NONE DECLARED SUMMARY Introduction Agency for healthcare quality and accreditation in Federation of Bosnia and Herzegovina (AKAZ) is authorized body in the field of healthcare quality and safety improvement and accreditation of healthcare institutions. Beside accreditation standards for hospitals and primary health care centers, AKAZ has also developed accreditation standards for family medicine teams. Methods Software development was primarily based on Accreditation Standards for Family Medicine Teams. Seven chapters / topics: (1. Physical factors; 2. Equipment; 3. Organization and Management; 4. Health promotion and illness prevention; 5. Clinical services; 6. Patient survey; and 7. Patient’s rights and obligations) contain 35 standards describing expected level of family medicine team’s quality. Based on accreditation standards structure and needs of different potential users, it was concluded that software backbone should be a database containing all accreditation standards, self assessment and external assessment details. In this article we will present the development of standardized software for self and external evaluation of quality of service in family medicine, as well as plans for the future development of this software package. Conclusion Electronic data gathering and storing enhances the management, access and overall use of information. During this project we came to conclusion that software for self assessment and external assessment is ideal for accreditation standards distribution, their overview by the family medicine team members, their self assessment and external assessment. PMID:24109157
Podevin, Michael; Fotidis, Ioannis A; Angelidaki, Irini
2018-08-01
Microalgae are well known for their ability to accumulate lipids intracellularly, which can be used for biofuels and mitigate CO 2 emissions. However, due to economic challenges, microalgae bioprocesses have maneuvered towards the simultaneous production of food, feed, fuel, and various high-value chemicals in a biorefinery concept. On-line and in-line monitoring of macromolecules such as lipids, proteins, carbohydrates, and high-value pigments will be more critical to maintain product quality and consistency for downstream processing in a biorefinery to maintain and valorize these markets. The main contribution of this review is to present current and prospective advances of on-line and in-line process analytical technology (PAT), with high-selectivity - the capability of monitoring several analytes simultaneously - in the interest of improving product quality, productivity, and process automation of a microalgal biorefinery. The high-selectivity PAT under consideration are mid-infrared (MIR), near-infrared (NIR), and Raman vibrational spectroscopies. The current review contains a critical assessment of these technologies in the context of recent advances in software and hardware in order to move microalgae production towards process automation through multivariate process control (MVPC) and software sensors trained on "big data". The paper will also include a comprehensive overview of off-line implementations of vibrational spectroscopy in microalgal research as it pertains to spectral interpretation and process automation to aid and motivate development.
SAGA: A project to automate the management of software production systems
NASA Technical Reports Server (NTRS)
Campbell, Roy H.; Beckman-Davies, C. S.; Benzinger, L.; Beshers, G.; Laliberte, D.; Render, H.; Sum, R.; Smith, W.; Terwilliger, R.
1986-01-01
Research into software development is required to reduce its production cost and to improve its quality. Modern software systems, such as the embedded software required for NASA's space station initiative, stretch current software engineering techniques. The requirements to build large, reliable, and maintainable software systems increases with time. Much theoretical and practical research is in progress to improve software engineering techniques. One such technique is to build a software system or environment which directly supports the software engineering process, i.e., the SAGA project, comprising the research necessary to design and build a software development which automates the software engineering process. Progress under SAGA is described.
A Fast and Scalable Radiation Hybrid Map Construction and Integration Strategy
Agarwala, Richa; Applegate, David L.; Maglott, Donna; Schuler, Gregory D.; Schäffer, Alejandro A.
2000-01-01
This paper describes a fast and scalable strategy for constructing a radiation hybrid (RH) map from data on different RH panels. The maps on each panel are then integrated to produce a single RH map for the genome. Recurring problems in using maps from several sources are that the maps use different markers, the maps do not place the overlapping markers in same order, and the objective functions for map quality are incomparable. We use methods from combinatorial optimization to develop a strategy that addresses these issues. We show that by the standard objective functions of obligate chromosome breaks and maximum likelihood, software for the traveling salesman problem produces RH maps with better quality much more quickly than using software specifically tailored for RH mapping. We use known algorithms for the longest common subsequence problem as part of our map integration strategy. We demonstrate our methods by reconstructing and integrating maps for markers typed on the Genebridge 4 (GB4) and the Stanford G3 panels publicly available from the RH database. We compare map quality of our integrated map with published maps for GB4 panel and G3 panel by considering whether markers occur in the same order on a map and in DNA sequence contigs submitted to GenBank. We find that all of the maps are inconsistent with the sequence data for at least 50% of the contigs, but our integrated maps are more consistent. The map integration strategy not only scales to multiple RH maps but also to any maps that have comparable criteria for measuring map quality. Our software improves on current technology for doing RH mapping in areas of computation time and algorithms for considering a large number of markers for mapping. The essential impediments to producing dense high-quality RH maps are data quality and panel size, not computation. PMID:10720576
Monks, K; Molnár, I; Rieger, H-J; Bogáti, B; Szabó, E
2012-04-06
Robust HPLC separations lead to fewer analysis failures and better method transfer as well as providing an assurance of quality. This work presents the systematic development of an optimal, robust, fast UHPLC method for the simultaneous assay of two APIs of an eye drop sample and their impurities, in accordance with Quality by Design principles. Chromatography software is employed to effectively generate design spaces (Method Operable Design Regions), which are subsequently employed to determine the final method conditions and to evaluate robustness prior to validation. Copyright © 2011 Elsevier B.V. All rights reserved.
ExpertEyes: open-source, high-definition eyetracking.
Parada, Francisco J; Wyatte, Dean; Yu, Chen; Akavipat, Ruj; Emerick, Brandi; Busey, Thomas
2015-03-01
ExpertEyes is a low-cost, open-source package of hardware and software that is designed to provide portable high-definition eyetracking. The project involves several technological innovations, including portability, high-definition video recording, and multiplatform software support. It was designed for challenging recording environments, and all processing is done offline to allow for optimization of parameter estimation. The pupil and corneal reflection are estimated using a novel forward eye model that simultaneously fits both the pupil and the corneal reflection with full ellipses, addressing a common situation in which the corneal reflection sits at the edge of the pupil and therefore breaks the contour of the ellipse. The accuracy and precision of the system are comparable to or better than what is available in commercial eyetracking systems, with a typical accuracy of less than 0.4° and best accuracy below 0.3°, and with a typical precision (SD method) around 0.3° and best precision below 0.2°. Part of the success of the system comes from a high-resolution eye image. The high image quality results from uncasing common digital camcorders and recording directly to SD cards, which avoids the limitations of the analog NTSC format. The software is freely downloadable, and complete hardware plans are available, along with sources for custom parts.
Guidance and Control Software Project Data - Volume 1: Planning Documents
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J. (Editor)
2008-01-01
The Guidance and Control Software (GCS) project was the last in a series of software reliability studies conducted at Langley Research Center between 1977 and 1994. The technical results of the GCS project were recorded after the experiment was completed. Some of the support documentation produced as part of the experiment, however, is serving an unexpected role far beyond its original project context. Some of the software used as part of the GCS project was developed to conform to the RTCA/DO-178B software standard, "Software Considerations in Airborne Systems and Equipment Certification," used in the civil aviation industry. That standard requires extensive documentation throughout the software development life cycle, including plans, software requirements, design and source code, verification cases and results, and configuration management and quality control data. The project documentation that includes this information is open for public scrutiny without the legal or safety implications associated with comparable data from an avionics manufacturer. This public availability has afforded an opportunity to use the GCS project documents for DO-178B training. This report provides a brief overview of the GCS project, describes the 4-volume set of documents and the role they are playing in training, and includes the planning documents from the GCS project. Volume 1 contains five appendices: A. Plan for Software Aspects of Certification for the Guidance and Control Software Project; B. Software Development Standards for the Guidance and Control Software Project; C. Software Verification Plan for the Guidance and Control Software Project; D. Software Configuration Management Plan for the Guidance and Control Software Project; and E. Software Quality Assurance Activities.
Using Compilers to Enhance Cryptographic Product Development
NASA Astrophysics Data System (ADS)
Bangerter, E.; Barbosa, M.; Bernstein, D.; Damgård, I.; Page, D.; Pagter, J. I.; Sadeghi, A.-R.; Sovio, S.
Developing high-quality software is hard in the general case, and it is significantly more challenging in the case of cryptographic software. A high degree of new skill and understanding must be learnt and applied without error to avoid vulnerability and inefficiency. This is often beyond the financial, manpower or intellectual resources avail-able. In this paper we present the motivation for the European funded CACE (Computer Aided Cryptography Engineering) project The main objective of CACE is to provide engineers (with limited or no expertise in cryptography) with a toolbox that allows them to generate robust and efficient implementations of cryptographic primitives. We also present some preliminary results already obtained in the early stages of this project, and discuss the relevance of the project as perceived by stakeholders in the mobile device arena.
A proposed research program in information processing
NASA Technical Reports Server (NTRS)
Schorr, Herbert
1992-01-01
The goal of the Formalized Software Development (FSD) project was to demonstrate improvements productivity of software development and maintenance through the use of a new software lifecycle paradigm. The paradigm calls for the mechanical, but human-guided, derivation of software implementations from formal specifications of the desired software behavior. It relies on altering a system's specification and rederiving its implementation as the standard technology for software maintenance. A system definition for this paradigm is composed of a behavioral specification together with a body of annotations that control the derivation of executable code from the specification. Annotations generally achieve the selection of certain data representations and/or algorithms that are consistent with, but not mandated by, the behavioral specification. In doing this, they may yield systems which exhibit only certain behaviors among multiple alternatives permitted by the behavioral specification. The FSD project proposed to construct a testbed in which to explore the realization of this new paradigm. The testbed was to provide operational support environment for software design, implementation, and maintenance. The testbed was proposed to provide highly automated support for individual programmers ('programming in the small'), but not to address the additional needs of programming teams ('programming in the large'). The testbed proposed to focus on supporting rapid construction and evolution of useful prototypes of software systems, as opposed to focusing on the problems of achieving production quality performance of systems.
New generation of exploration tools: interactive modeling software and microcomputers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krajewski, S.A.
1986-08-01
Software packages offering interactive modeling techniques are now available for use on microcomputer hardware systems. These packages are reasonably priced for both company and independent explorationists; they do not require users to have high levels of computer literacy; they are capable of rapidly completing complex ranges of sophisticated geologic and geophysical modeling tasks; and they can produce presentation-quality output for comparison with real-world data. For example, interactive packages are available for mapping, log analysis, seismic modeling, reservoir studies, and financial projects as well as for applying a variety of statistical and geostatistical techniques to analysis of exploration data. More importantly,more » these packages enable explorationists to directly apply their geologic expertise when developing and fine-tuning models for identifying new prospects and for extending producing fields. As a result of these features, microcomputers and interactive modeling software are becoming common tools in many exploration offices. Gravity and magnetics software programs illustrate some of the capabilities of such exploration tools.« less
Mining dynamic noteworthy functions in software execution sequences.
Zhang, Bing; Huang, Guoyan; Wang, Yuqian; He, Haitao; Ren, Jiadong
2017-01-01
As the quality of crucial entities can directly affect that of software, their identification and protection become an important premise for effective software development, management, maintenance and testing, which thus contribute to improving the software quality and its attack-defending ability. Most analysis and evaluation on important entities like codes-based static structure analysis are on the destruction of the actual software running. In this paper, from the perspective of software execution process, we proposed an approach to mine dynamic noteworthy functions (DNFM)in software execution sequences. First, according to software decompiling and tracking stack changes, the execution traces composed of a series of function addresses were acquired. Then these traces were modeled as execution sequences and then simplified so as to get simplified sequences (SFS), followed by the extraction of patterns through pattern extraction (PE) algorithm from SFS. After that, evaluating indicators inner-importance and inter-importance were designed to measure the noteworthiness of functions in DNFM algorithm. Finally, these functions were sorted by their noteworthiness. Comparison and contrast were conducted on the experiment results from two traditional complex network-based node mining methods, namely PageRank and DegreeRank. The results show that the DNFM method can mine noteworthy functions in software effectively and precisely.
A review of the FDA draft guidance document for software validation: guidance for industry.
Keatley, K L
1999-01-01
A Draft Guidance Document (Version 1.1) was issued by the United States Food and Drug Administration (FDA) to address the software validation requirement of the Quality System Regulation, 21 CFR Part 820, effective June 1, 1997. The guidance document outlines validation considerations that the FDA regards as applicable to both medical device software and software used to "design, develop or manufacture" medical devices. The Draft Guidance is available at the FDA web site http:@www.fda.gov/cdrh/comps/swareval++ +.html. Presented here is a review of the main features of the FDA document for Quality System Regulation (QSR), and some guidance for its implementation in industry.
Espinoza, A; Petasecca, M; Fuduli, I; Howie, A; Bucci, J; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B
2015-02-01
High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named "magic phantom" (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the "position-time gamma index," was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position-time gamma index showed that all modifications made could be readily detected. The MPh was able to measure dwell times down to 0.067 ± 0.001 s and planned dwell positions separated by 1 mm. The dose calculation carried out by the MPh software was found to be in agreement with values calculated by the treatment planning system within 0.75%. Using the 2D gamma index, the dose map of the MPh plane and measured EBT3 were found to have a pass rate of over 95% when compared to the original plan. The application of this magic phantom quality assurance system to HDR brachytherapy has demonstrated promising ability to perform the verification of treatment plans, based upon the measured dwell positions and times. The introduction of the quantitative position-time gamma index allows for direct comparison of measured parameters against the plan and could be used prior to patient treatment to ensure accurate delivery. © 2015 American Association of Physicists in Medicine.
Rules of thumb to increase the software quality through testing
NASA Astrophysics Data System (ADS)
Buttu, M.; Bartolini, M.; Migoni, C.; Orlati, A.; Poppi, S.; Righini, S.
2016-07-01
The software maintenance typically requires 40-80% of the overall project costs, and this considerable variability mostly depends on the software internal quality: the more the software is designed and implemented to constantly welcome new changes, the lower will be the maintenance costs. The internal quality is typically enforced through testing, which in turn also affects the development and maintenance costs. This is the reason why testing methodologies have become a major concern for any company that builds - or is involved in building - software. Although there is no testing approach that suits all contexts, we infer some general guidelines learned during the Development of the Italian Single-dish COntrol System (DISCOS), which is a project aimed at producing the control software for the three INAF radio telescopes (the Medicina and Noto dishes, and the newly-built SRT). These guidelines concern both the development and the maintenance phases, and their ultimate goal is to maximize the DISCOS software quality through a Behavior-Driven Development (BDD) workflow beside a continuous delivery pipeline. We consider different topics and patterns; they involve the proper apportion of the tests (from end-to-end to low-level tests), the choice between hardware simulators and mockers, why and how to apply TDD and the dependency injection to increase the test coverage, the emerging technologies available for test isolation, bug fixing, how to protect the system from the external resources changes (firmware updating, hardware substitution, etc.) and, eventually, how to accomplish BDD starting from functional tests and going through integration and unit tests. We discuss pros and cons of each solution and point out the motivations of our choices either as a general rule or narrowed in the context of the DISCOS project.
NASA Technical Reports Server (NTRS)
2004-01-01
Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.
Image-Based Single Cell Profiling: High-Throughput Processing of Mother Machine Experiments
Sachs, Christian Carsten; Grünberger, Alexander; Helfrich, Stefan; Probst, Christopher; Wiechert, Wolfgang; Kohlheyer, Dietrich; Nöh, Katharina
2016-01-01
Background Microfluidic lab-on-chip technology combined with live-cell imaging has enabled the observation of single cells in their spatio-temporal context. The mother machine (MM) cultivation system is particularly attractive for the long-term investigation of rod-shaped bacteria since it facilitates continuous cultivation and observation of individual cells over many generations in a highly parallelized manner. To date, the lack of fully automated image analysis software limits the practical applicability of the MM as a phenotypic screening tool. Results We present an image analysis pipeline for the automated processing of MM time lapse image stacks. The pipeline supports all analysis steps, i.e., image registration, orientation correction, channel/cell detection, cell tracking, and result visualization. Tailored algorithms account for the specialized MM layout to enable a robust automated analysis. Image data generated in a two-day growth study (≈ 90 GB) is analyzed in ≈ 30 min with negligible differences in growth rate between automated and manual evaluation quality. The proposed methods are implemented in the software molyso (MOther machine AnaLYsis SOftware) that provides a new profiling tool to analyze unbiasedly hitherto inaccessible large-scale MM image stacks. Conclusion Presented is the software molyso, a ready-to-use open source software (BSD-licensed) for the unsupervised analysis of MM time-lapse image stacks. molyso source code and user manual are available at https://github.com/modsim/molyso. PMID:27661996
Inwood, Matthew J; Ahmad, Jamil
2005-11-01
Although dissection provides an unparalleled means of teaching gross anatomy, it constitutes a significant logistical and financial investment for educational institutions. The increasing availability and waning cost of computer equipment has enabled many institutions to supplement their anatomy curriculum with Computer Aided Learning (CAL) software. At the Royal College of Surgeons in Ireland, two undergraduate medical students designed and produced instructional anatomy dissection software for use by first and second year medical students. The software consists of full-motion, narrated, QuickTime MPG movies presented in a Macromedia environment. Forty-four movies, between 1-11 min in duration, were produced. Each movie corresponds to a dissection class and precisely demonstrates the dissection and educational objectives for that class. The software is distributed to students free of charge and they are encouraged to install it on their Apple iBook computers. Results of a student evaluation indicated that the software was useful, easy to use, and improved the students' experience in the dissection classes. The evaluation also indicated that only a minority of students regularly used the software or had it installed on their laptop computers. Accordingly, effort should also be directed toward making the software more accessible and increasing students' comfort and familiarity with novel instructional media. The successful design and implementation of this software demonstrates that CAL software can be employed to augment, enhance and improve anatomy instruction. In addition, effective, high quality, instructional multimedia software can be tailored to an educational institution's requirements and produced by novice programmers at minimal cost. Copyright 2005 Wiley-Liss, Inc
Wang, Xiaofeng; Abrahamsson, Pekka
2014-01-01
For more than thirty years, it has been claimed that a way to improve software developers’ productivity and software quality is to focus on people and to provide incentives to make developers satisfied and happy. This claim has rarely been verified in software engineering research, which faces an additional challenge in comparison to more traditional engineering fields: software development is an intellectual activity and is dominated by often-neglected human factors (called human aspects in software engineering research). Among the many skills required for software development, developers must possess high analytical problem-solving skills and creativity for the software construction process. According to psychology research, affective states—emotions and moods—deeply influence the cognitive processing abilities and performance of workers, including creativity and analytical problem solving. Nonetheless, little research has investigated the correlation between the affective states, creativity, and analytical problem-solving performance of programmers. This article echoes the call to employ psychological measurements in software engineering research. We report a study with 42 participants to investigate the relationship between the affective states, creativity, and analytical problem-solving skills of software developers. The results offer support for the claim that happy developers are indeed better problem solvers in terms of their analytical abilities. The following contributions are made by this study: (1) providing a better understanding of the impact of affective states on the creativity and analytical problem-solving capacities of developers, (2) introducing and validating psychological measurements, theories, and concepts of affective states, creativity, and analytical-problem-solving skills in empirical software engineering, and (3) raising the need for studying the human factors of software engineering by employing a multidisciplinary viewpoint. PMID:24688866
Graziotin, Daniel; Wang, Xiaofeng; Abrahamsson, Pekka
2014-01-01
For more than thirty years, it has been claimed that a way to improve software developers' productivity and software quality is to focus on people and to provide incentives to make developers satisfied and happy. This claim has rarely been verified in software engineering research, which faces an additional challenge in comparison to more traditional engineering fields: software development is an intellectual activity and is dominated by often-neglected human factors (called human aspects in software engineering research). Among the many skills required for software development, developers must possess high analytical problem-solving skills and creativity for the software construction process. According to psychology research, affective states-emotions and moods-deeply influence the cognitive processing abilities and performance of workers, including creativity and analytical problem solving. Nonetheless, little research has investigated the correlation between the affective states, creativity, and analytical problem-solving performance of programmers. This article echoes the call to employ psychological measurements in software engineering research. We report a study with 42 participants to investigate the relationship between the affective states, creativity, and analytical problem-solving skills of software developers. The results offer support for the claim that happy developers are indeed better problem solvers in terms of their analytical abilities. The following contributions are made by this study: (1) providing a better understanding of the impact of affective states on the creativity and analytical problem-solving capacities of developers, (2) introducing and validating psychological measurements, theories, and concepts of affective states, creativity, and analytical-problem-solving skills in empirical software engineering, and (3) raising the need for studying the human factors of software engineering by employing a multidisciplinary viewpoint.
NASA Astrophysics Data System (ADS)
Heeager, Lise Tordrup; Tjørnehøj, Gitte
Quality assurance technology is a formal control mechanism aiming at increasing the quality of the product exchanged between vendors and customers. Studies of the adoption of this technology in the field of system development rarely focus on the role of the relationship between the customer and vendor in the process. We have studied how the process of adopting quality assurance technology by a small Danish IT vendor developing pharmacy software for a customer in the public sector was influenced by the relationship with the customer. The case study showed that the adoption process was shaped to a high degree by the relationship and vice versa. The prior high level of trust and mutual knowledge helped the parties negotiate mutually feasible solutions throughout the adoption process. We thus advise enhancing trust-building processes to strengthen the relationships and to balance formal control and social control to increase the likelihood of a successful outcome of the adoption of quality assurance technology in a customer-vendor relationship.
Image Quality Ranking Method for Microscopy
Koho, Sami; Fazeli, Elnaz; Eriksson, John E.; Hänninen, Pekka E.
2016-01-01
Automated analysis of microscope images is necessitated by the increased need for high-resolution follow up of events in time. Manually finding the right images to be analyzed, or eliminated from data analysis are common day-to-day problems in microscopy research today, and the constantly growing size of image datasets does not help the matter. We propose a simple method and a software tool for sorting images within a dataset, according to their relative quality. We demonstrate the applicability of our method in finding good quality images in a STED microscope sample preparation optimization image dataset. The results are validated by comparisons to subjective opinion scores, as well as five state-of-the-art blind image quality assessment methods. We also show how our method can be applied to eliminate useless out-of-focus images in a High-Content-Screening experiment. We further evaluate the ability of our image quality ranking method to detect out-of-focus images, by extensive simulations, and by comparing its performance against previously published, well-established microscopy autofocus metrics. PMID:27364703
The Role and Quality of Software Safety in the NASA Constellation Program
NASA Technical Reports Server (NTRS)
Layman, Lucas; Basili, Victor R.; Zelkowitz, Marvin V.
2010-01-01
In this study, we examine software safety risk in the early design phase of the NASA Constellation spaceflight program. Obtaining an accurate, program-wide picture of software safety risk is difficult across multiple, independently-developing systems. We leverage one source of safety information, hazard analysis, to provide NASA quality assurance managers with information regarding the ongoing state of software safety across the program. The goal of this research is two-fold: 1) to quantify the relative importance of software with respect to system safety; and 2) to quantify the level of risk presented by software in the hazard analysis. We examined 154 hazard reports created during the preliminary design phase of three major flight hardware systems within the Constellation program. To quantify the importance of software, we collected metrics based on the number of software-related causes and controls of hazardous conditions. To quantify the level of risk presented by software, we created a metric scheme to measure the specificity of these software causes. We found that from 49-70% of hazardous conditions in the three systems could be caused by software or software was involved in the prevention of the hazardous condition. We also found that 12-17% of the 2013 hazard causes involved software, and that 23-29% of all causes had a software control. Furthermore, 10-12% of all controls were software-based. There is potential for inaccuracy in these counts, however, as software causes are not consistently scoped, and the presence of software in a cause or control is not always clear. The application of our software specificity metrics also identified risks in the hazard reporting process. In particular, we found a number of traceability risks in the hazard reports may impede verification of software and system safety.
NASA Astrophysics Data System (ADS)
Vavulin, M. V.
2017-11-01
Old Turkic runic inscriptions of the Altai Mountains (8th-9th centuries AD) were digitized in the course of this project to be preserved in the current state on the Web and deciphered by linguistic experts. The ways the inscriptions were made as well as their location in hardly accessible areas required finding an inexpensive solution that would provide detailed 3D documentation of rock faces, while at the same time mobility and autonomy. Digital photogrammetry came as a quite affordable and optimal choice for getting high-quality outcomes using inexpensive software and further data processing using free software.
Time-lapse systems for embryo incubation and assessment in assisted reproduction.
Armstrong, Sarah; Bhide, Priya; Jordan, Vanessa; Pacey, Allan; Farquhar, Cindy
2018-05-25
Embryo incubation and assessment is a vital step in assisted reproductive technology (ART). Traditionally, embryo assessment has been achieved by removing embryos from a conventional incubator daily for quality assessment by an embryologist, under a light microscope. Over recent years time-lapse systems have been developed which can take digital images of embryos at frequent time intervals. This allows embryologists, with or without the assistance of embryo selection software, to assess the quality of the embryos without physically removing them from the incubator.The potential advantages of a time-lapse system (TLS) include the ability to maintain a stable culture environment, therefore limiting the exposure of embryos to changes in gas composition, temperature and movement. A TLS has the potential advantage of improving embryo selection for ART treatment by utilising additional information gained through continuously monitoring embryo development. Use of a TLS often adds significant extra cost onto an in vitro fertilisation (IVF) cycle. To determine the effect of a TLS compared to conventional embryo incubation and assessment on clinical outcomes in couples undergoing ART. We used standard methodology recommended by Cochrane. We searched the Cochrane Gynaecology and Fertility (CGF) Group trials register, CENTRAL, MEDLINE, Embase, CINAHL and two trials registers on 2 August 2017. We included randomised controlled trials (RCTs) in the following comparisons: comparing a TLS, with or without embryo selection software, versus conventional incubation with morphological assessment; and TLS with embryo selection software versus TLS without embryo selection software among couples undergoing ART. We used standard methodological procedures recommended by Cochrane. The primary review outcomes were live birth, miscarriage and stillbirth. Secondary outcomes were clinical pregnancy and cumulative clinical pregnancy. We reported quality of the evidence for important outcomes using GRADE methodology. We made the following comparisons.TLS with conventional morphological assessment of still TLS images versus conventional incubation and assessmentTLS utilising embryo selection software versus TLS with conventional morphological assessment of still TLS images TLS utilising embryo selection software versus conventional incubation and assessment MAIN RESULTS: We included eight RCTs (N = 2303 women). The quality of the evidence ranged from very low to moderate. The main limitations were imprecision and risk of bias associated with lack of blinding of participants and researchers, and indirectness secondary to significant heterogeneity between interventions in some studies. There were no data on cumulative clinical pregnancy.TLS with conventional morphological assessment of still TLS images versus conventional incubation and assessmentThere is no evidence of a difference between the interventions in terms of live birth rates (odds ratio (OR) 0.73, 95% CI 0.47 to 1.13, 2 RCTs, N = 440, I 2 = 11% , moderate-quality evidence) and may also be no evidence of difference in miscarriage rates (OR 2.25, 95% CI 0.84 to 6.02, 2 RCTs, N = 440, I 2 = 44%, low-quality evidence). The evidence suggests that if the live birth rate associated with conventional incubation and assessment is 33%, the rate with use of TLS with conventional morphological assessment of still TLS images is between 19% and 36%; and that if the miscarriage rate with conventional incubation is 3%, the rate associated with conventional morphological assessment of still TLS images would be between 3% and 18%. There is no evidence of a difference between the interventions in the stillbirth rate (OR 1.00, 95% CI 0.13 to 7.49, 1 RCT, N = 76, low-quality evidence). There is no evidence of a difference between the interventions in clinical pregnancy rates (OR 0.88, 95% CI 0.58 to 1.33, 3 RCTs, N = 489, I 2 = 0%, moderate-quality evidence).TLS utilising embryo selection software versus TLS with conventional morphological assessment of still TLS imagesNo data were available on live birth or stillbirth. We are uncertain whether TLS utilising embryo selection software influences miscarriage rates (OR 1.39, 95% CI 0.64 to 3.01, 2 RCTs, N = 463, I 2 = 0%, very low-quality evidence) and there may be no difference in clinical pregnancy rates (OR 0.97, 95% CI 0.67 to 1.42, 2 RCTs, N = 463, I 2 = 0%, low-quality evidence). The evidence suggests that if the miscarriage rate associated with assessment of still TLS images is 5%, the rate with embryo selection software would be between 3% and 14%.TLS utilising embryo selection software versus conventional incubation and assessmentThere is no evidence of a difference between TLS utilising embryo selection software and conventional incubation improving live birth rates (OR 1.21, 95% CI 0.96 to 1.54, 2 RCTs, N = 1017, I 2 = 0%, very low-quality evidence). We are uncertain whether TLS influences miscarriage rates (OR 0.73, 95% CI 0.49 to 1.08, 3 RCTs, N = 1351, I 2 = 0%, very low-quality evidence). The evidence suggests that if the live birth rate associated with no TLS is 38%, the rate with use of conventional incubation would be between 36% and 58%, and that if miscarriage rate with conventional incubation is 9%, the rate associated with TLS would be between 4% and 10%. No data on stillbirths were available. It was uncertain whether the intervention influenced clinical pregnancy rates (OR 1.17, 95% CI 0.94 to 1.45, 3 RCTs, N = 1351, I 2 = 42%, very low-quality evidence). There is insufficient evidence of differences in live birth, miscarriage, stillbirth or clinical pregnancy to choose between TLS, with or without embryo selection software, and conventional incubation. The studies were at high risk of bias for randomisation and allocation concealment, the result should be interpreted with extreme caution.
The six critical attributes of the next generation of quality management software systems.
Clark, Kathleen
2011-07-01
Driven by both the need to meet regulatory requirements and a genuine desire to drive improved quality, quality management systems encompassing standard operating procedure, corrective and preventative actions and related processes have existed for many years, both in paper and electronic form. The impact of quality management systems on 'actual' quality, however, is often reported as far less than desired. A quality management software system that moves beyond formal forms-driven processes to include a true closed loop design, manage disparate processes across the enterprise, provide support for collaborative processes and deliver insight into the overall state of control has the potential to close the gap between simply accomplishing regulatory compliance and delivering measurable improvements in quality and efficiency.
Enhancements to the EPANET-RTX (Real-Time Analytics) ...
Technical brief and software The U.S. Environmental Protection Agency (EPA) developed EPANET-RTX as a collection of object-oriented software libraries comprising the core data access, data transformation, and data synthesis (real-time analytics) components of a real-time hydraulic and water quality modeling system. While EPANET-RTX uses the hydraulic and water quality solvers of EPANET, the object libraries are a self-contained set of building blocks for software developers. “Real-time EPANET” promises to change the way water utilities, commercial vendors, engineers, and the water community think about modeling.
Evolving the ECSS Standards and their Use: Experience Based on Industrial Case Studies
NASA Astrophysics Data System (ADS)
Feldt, R.; Ahmad, E.; Raza, B.; Hult, E.; Nordebäck, T.
2009-05-01
This paper introduces two case studies conducted at two Swedish companies developing software for the space industry. The overall goal of the project is to evaluate if current use of ECSS is cost efficient and if there are ways to make the process leaner while maintaining quality. The case studies reported on here focused on how the ECSS standard was used by the companies and how that affected software development processes and software quality. This paper describes the results and recommendations based on identified challenges.
Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa
2009-12-01
Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.
Data-Driven Decision Making as a Tool to Improve Software Development Productivity
ERIC Educational Resources Information Center
Brown, Mary Erin
2013-01-01
The worldwide software project failure rate, based on a survey of information technology software manager's view of user satisfaction, product quality, and staff productivity, is estimated to be between 24% and 36% and software project success has not kept pace with the advances in hardware. The problem addressed by this study was the limited…
2005 8th Annual Systems Engineering Conference. Volume 4, Thursday
2005-10-27
requirements, allocation , and utilization statistics Operations Decisions Acquisition Decisions Resource Management — Integrated Requirements/ Allocation ...Quality Improvement Consultants, Inc. “Automated Software Testing Increases Test Quality and Coverage Resulting in Improved Software Reliability.”, Mr...Steven Ligon, SAIC The Return of Discipline, Ms. Jacqueline Townsend, Air Force Materiel Command Track 4 - Net Centric Operations: Testing Net-Centric
ERIC Educational Resources Information Center
Smith, James Robert
2012-01-01
This cross-sectional study explored how IT system and software development team members communicated in the workplace and whether teams that used more verbal communication (and less text-based communication) experienced higher levels of collaboration as measured using the Teamwork Quality (TWQ) scale. Although computer-mediated communication tools…
Standard classification of software documentation
NASA Technical Reports Server (NTRS)
Tausworthe, R. C.
1976-01-01
General conceptual requirements for standard levels of documentation and for application of these requirements to intended usages. These standards encourage the policy to produce only those forms of documentation that are needed and adequate for the purpose. Documentation standards are defined with respect to detail and format quality. Classes A through D range, in order, from the most definitive down to the least definitive, and categories 1 through 4 range, in order, from high-quality typeset down to handwritten material. Criteria for each of the classes and categories, as well as suggested selection guidelines for each are given.
2010-01-01
Soporte de Modelos Sistémicos: Aplicación al Sector de Desarrollo de Software de Argentina,” Tesis de PhD, Universidad Tecnológica Nacional-Facultad...with New Results 31 2.3 Other Simulation Approaches 37 Conceptual Planning , Execution, and Operation of Combat Fire Support Effectiveness: A...Figure 29: Functional Structure of Multiple Regression Model 80 Figure 30: TSP Quality Plan One 85 Figure 31: TSP Quality Plan Two 85 Figure
Davenport, Paul B; Carter, Kimberly F; Echternach, Jeffrey M; Tuck, Christopher R
2018-02-01
High-reliability organizations (HROs) demonstrate unique and consistent characteristics, including operational sensitivity and control, situational awareness, hyperacute use of technology and data, and actionable process transformation. System complexity and reliance on information-based processes challenge healthcare organizations to replicate HRO processes. This article describes a healthcare organization's 3-year journey to achieve key HRO features to deliver high-quality, patient-centric care via an operations center powered by the principles of high-reliability data and software to impact patient throughput and flow.
Software for aerospace education: A bibliography, 2nd edition
NASA Technical Reports Server (NTRS)
Vogt, Gregory L.; Roth, Susan Kies; Phelps, Malcom V.
1990-01-01
This is the second aerospace education software bibliography to be published by the NASA Educational Technology Branch in Washington, DC. Unlike many software bibliographies, this bibliography does not evaluate and grade software according to its quality and value to the classroom, nor does it make any endorsements or warrant scientific accuracy. Rather, it describes software, its subject, approach, and technical details. This bibliography is intended as a convenience to educators. The specific software included represents replies to more than 300 queries to software producers for aerospace education programs.
Quality Assurance of RNA Expression Profiling in Clinical Laboratories
Tang, Weihua; Hu, Zhiyuan; Muallem, Hind; Gulley, Margaret L.
2012-01-01
RNA expression profiles are increasingly used to diagnose and classify disease, based on expression patterns of as many as several thousand RNAs. To ensure quality of expression profiling services in clinical settings, a standard operating procedure incorporates multiple quality indicators and controls, beginning with preanalytic specimen preparation and proceeding thorough analysis, interpretation, and reporting. Before testing, histopathological examination of each cellular specimen, along with optional cell enrichment procedures, ensures adequacy of the input tissue. Other tactics include endogenous controls to evaluate adequacy of RNA and exogenous or spiked controls to evaluate run- and patient-specific performance of the test system, respectively. Unique aspects of quality assurance for array-based tests include controls for the pertinent outcome signatures that often supersede controls for each individual analyte, built-in redundancy for critical analytes or biochemical pathways, and software-supported scrutiny of abundant data by a laboratory physician who interprets the findings in a manner facilitating appropriate medical intervention. Access to high-quality reagents, instruments, and software from commercial sources promotes standardization and adoption in clinical settings, once an assay is vetted in validation studies as being analytically sound and clinically useful. Careful attention to the well-honed principles of laboratory medicine, along with guidance from government and professional groups on strategies to preserve RNA and manage large data sets, promotes clinical-grade assay performance. PMID:22020152
Pallagi, Edina; Ambrus, Rita; Szabó-Révész, Piroska; Csóka, Ildikó
2015-08-01
Regulatory science based pharmaceutical development and product manufacturing is highly recommended by the authorities nowadays. The aim of this study was to adapt regulatory science even in the nano-pharmaceutical early development. Authors applied the quality by design (QbD) concept in the early development phase of nano-systems, where the illustration material was meloxicam. The meloxicam nanoparticles produced by co-grinding method for nasal administration were studied according to the QbD policy and the QbD based risk assessment (RA) was performed. The steps were implemented according to the relevant regulatory guidelines (quality target product profile (QTPP) determination, selection of critical quality attributes (CQAs) and critical process parameters (CPPs)) and a special software (Lean QbD Software(®)) was used for the RA, which represents a novelty in this field. The RA was able to predict and identify theoretically the factors (e.g. sample composition, production method parameters, etc.) which have the highest impact on the desired meloxicam-product quality. The results of the practical research justified the theoretical prediction. This method can improve pharmaceutical nano-developments by achieving shorter development time, lower cost, saving human resource efforts and more effective target-orientation. It makes possible focusing the resources on the selected parameters and area during the practical product development. Copyright © 2015 Elsevier B.V. All rights reserved.
A comprehensive and efficient daily quality assurance for PBS proton therapy
NASA Astrophysics Data System (ADS)
Actis, O.; Meer, D.; König, S.; Weber, D. C.; Mayor, A.
2017-03-01
There are several general recommendations for quality assurance (QA) measures, which have to be performed at proton therapy centres. However, almost each centre uses a different therapy system. In particular, there is no standard procedure for centres employing pencil beam scanning and each centre applies a specific QA program. Gantry 2 is an operating therapy system which was developed at PSI and relies on the most advanced technological innovations. We developed a comprehensive daily QA program in order to verify the main beam characteristics to assure the functionality of the therapy delivery system and the patient safety system. The daily QA program entails new hardware and software solutions for a highly efficient clinical operation. In this paper, we describe a dosimetric phantom used for verifying the most critical beam parameters and the software architecture developed for a fully automated QA procedure. The connection between our QA software and the database allows us to store the data collected on a daily basis and use it for trend analysis over longer periods of time. All the data presented here have been collected during a time span of over two years, since the beginning of the Gantry 2 clinical operation in 2013. Our procedure operates in a stable way and delivers the expected beam quality. The daily QA program takes only 20 min. At the same time, the comprehensive approach allows us to avoid most of the weekly and monthly QA checks and increases the clinical beam availability.
Podcasting: contemporary patient education.
Abreu, Daniel V; Tamura, Thomas K; Sipp, J Andrew; Keamy, Donald G; Eavey, Roland D
2008-04-01
Portable video technology is a widely available new tool with potential to be used by pediatric otolaryngology practices for patient and family education. Podcasts are media broadcasts that employ this new technology. They can be accessed via the Internet and viewed either on a personal computer or on a handheld device, such as an iPod or an MP3 player. We wished to examine the feasibility of establishing a podcast-hosting Web site. We digitally recorded pediatric otologic procedures in the operating room and saved the digital files to DVDs. We then edited the DVDs at home with video-editing software on a personal computer. Next, spoken narrative was recorded with audio-recording software and combined with the edited video clips. The final products were converted into the M4V file format, and the final versions were uploaded onto our hospital's Web site. We then downloaded the podcasts onto a high-quality portable media player so that we could evaluate their quality. All of the podcasts are now on the hospital Web site, where they can be downloaded by patients and families at no cost. The site includes instructions on how to download the appropriate free software for viewing the podcasts on a portable media player or on a computer. Using this technology for patient education expands the audience and permits portability of information. We conclude that a home computer can be used to inexpensively create informative surgery demonstrations that can be accessed via a Web site and transferred to portable viewing devices with excellent quality.
A systematic literature review of open source software quality assessment models.
Adewumi, Adewole; Misra, Sanjay; Omoregbe, Nicholas; Crawford, Broderick; Soto, Ricardo
2016-01-01
Many open source software (OSS) quality assessment models are proposed and available in the literature. However, there is little or no adoption of these models in practice. In order to guide the formulation of newer models so they can be acceptable by practitioners, there is need for clear discrimination of the existing models based on their specific properties. Based on this, the aim of this study is to perform a systematic literature review to investigate the properties of the existing OSS quality assessment models by classifying them with respect to their quality characteristics, the methodology they use for assessment, and their domain of application so as to guide the formulation and development of newer models. Searches in IEEE Xplore, ACM, Science Direct, Springer and Google Search is performed so as to retrieve all relevant primary studies in this regard. Journal and conference papers between the year 2003 and 2015 were considered since the first known OSS quality model emerged in 2003. A total of 19 OSS quality assessment model papers were selected. To select these models we have developed assessment criteria to evaluate the quality of the existing studies. Quality assessment models are classified into five categories based on the quality characteristics they possess namely: single-attribute, rounded category, community-only attribute, non-community attribute as well as the non-quality in use models. Our study reflects that software selection based on hierarchical structures is found to be the most popular selection method in the existing OSS quality assessment models. Furthermore, we found that majority (47%) of the existing models do not specify any domain of application. In conclusion, our study will be a valuable contribution to the community and helps the quality assessment model developers in formulating newer models and also to the practitioners (software evaluators) in selecting suitable OSS in the midst of alternatives.
Taking advantage of ground data systems attributes to achieve quality results in testing software
NASA Technical Reports Server (NTRS)
Sigman, Clayton B.; Koslosky, John T.; Hageman, Barbara H.
1994-01-01
During the software development life cycle process, basic testing starts with the development team. At the end of the development process, an acceptance test is performed for the user to ensure that the deliverable is acceptable. Ideally, the delivery is an operational product with zero defects. However, the goal of zero defects is normally not achieved but is successful to various degrees. With the emphasis on building low cost ground support systems while maintaining a quality product, a key element in the test process is simulator capability. This paper reviews the Transportable Payload Operations Control Center (TPOCC) Advanced Spacecraft Simulator (TASS) test tool that is used in the acceptance test process for unmanned satellite operations control centers. The TASS is designed to support the development, test and operational environments of the Goddard Space Flight Center (GSFC) operations control centers. The TASS uses the same basic architecture as the operations control center. This architecture is characterized by its use of distributed processing, industry standards, commercial off-the-shelf (COTS) hardware and software components, and reusable software. The TASS uses much of the same TPOCC architecture and reusable software that the operations control center developer uses. The TASS also makes use of reusable simulator software in the mission specific versions of the TASS. Very little new software needs to be developed, mainly mission specific telemetry communication and command processing software. By taking advantage of the ground data system attributes, successful software reuse for operational systems provides the opportunity to extend the reuse concept into the test area. Consistency in test approach is a major step in achieving quality results.
Assessment Environment for Complex Systems Software Guide
NASA Technical Reports Server (NTRS)
2013-01-01
This Software Guide (SG) describes the software developed to test the Assessment Environment for Complex Systems (AECS) by the West Virginia High Technology Consortium (WVHTC) Foundation's Mission Systems Group (MSG) for the National Aeronautics and Space Administration (NASA) Aeronautics Research Mission Directorate (ARMD). This software is referred to as the AECS Test Project throughout the remainder of this document. AECS provides a framework for developing, simulating, testing, and analyzing modern avionics systems within an Integrated Modular Avionics (IMA) architecture. The purpose of the AECS Test Project is twofold. First, it provides a means to test the AECS hardware and system developed by MSG. Second, it provides an example project upon which future AECS research may be based. This Software Guide fully describes building, installing, and executing the AECS Test Project as well as its architecture and design. The design of the AECS hardware is described in the AECS Hardware Guide. Instructions on how to configure, build and use the AECS are described in the User's Guide. Sample AECS software, developed by the WVHTC Foundation, is presented in the AECS Software Guide. The AECS Hardware Guide, AECS User's Guide, and AECS Software Guide are authored by MSG. The requirements set forth for AECS are presented in the Statement of Work for the Assessment Environment for Complex Systems authored by NASA Dryden Flight Research Center (DFRC). The intended audience for this document includes software engineers, hardware engineers, project managers, and quality assurance personnel from WVHTC Foundation (the suppliers of the software), NASA (the customer), and future researchers (users of the software). Readers are assumed to have general knowledge in the field of real-time, embedded computer software development.
Churilov, Leonid; Liu, Daniel; Ma, Henry; Christensen, Soren; Nagakane, Yoshinari; Campbell, Bruce; Parsons, Mark W; Levi, Christopher R; Davis, Stephen M; Donnan, Geoffrey A
2013-04-01
The appropriateness of a software platform for rapid MRI assessment of the amount of salvageable brain tissue after stroke is critical for both the validity of the Extending the Time for Thrombolysis in Emergency Neurological Deficits (EXTEND) Clinical Trial of stroke thrombolysis beyond 4.5 hours and for stroke patient care outcomes. The objective of this research is to develop and implement a methodology for selecting the acute stroke imaging software platform most appropriate for the setting of a multi-centre clinical trial. A multi-disciplinary decision making panel formulated the set of preferentially independent evaluation attributes. Alternative Multi-Attribute Value Measurement methods were used to identify the best imaging software platform followed by sensitivity analysis to ensure the validity and robustness of the proposed solution. Four alternative imaging software platforms were identified. RApid processing of PerfusIon and Diffusion (RAPID) software was selected as the most appropriate for the needs of the EXTEND trial. A theoretically grounded generic multi-attribute selection methodology for imaging software was developed and implemented. The developed methodology assured both a high quality decision outcome and a rational and transparent decision process. This development contributes to stroke literature in the area of comprehensive evaluation of MRI clinical software. At the time of evaluation, RAPID software presented the most appropriate imaging software platform for use in the EXTEND clinical trial. The proposed multi-attribute imaging software evaluation methodology is based on sound theoretical foundations of multiple criteria decision analysis and can be successfully used for choosing the most appropriate imaging software while ensuring both robust decision process and outcomes. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.
NASA Technical Reports Server (NTRS)
Hancock, David W., III
1999-01-01
This document provides the Software Management Plan for the GLAS Standard Data Software (SDS) supporting the GLAS instrument of the EOS ICESat Spacecraft. The SDS encompasses the ICESat Science Investigator-led Processing System (I-SIPS) Software and the Instrument Support Terminal (IST) Software. For the I-SIPS Software, the SDS will produce Level 0, Level 1, and Level 2 data products as well as the associated product quality assessments and descriptive information. For the IST Software, the SDS will accommodate the GLAS instrument support areas of engineering status, command, performance assessment, and instrument health status.
A Prototype for the Support of Integrated Software Process Development and Improvement
NASA Astrophysics Data System (ADS)
Porrawatpreyakorn, Nalinpat; Quirchmayr, Gerald; Chutimaskul, Wichian
An efficient software development process is one of key success factors for quality software. Not only can the appropriate establishment but also the continuous improvement of integrated project management and of the software development process result in efficiency. This paper hence proposes a software process maintenance framework which consists of two core components: an integrated PMBOK-Scrum model describing how to establish a comprehensive set of project management and software engineering processes and a software development maturity model advocating software process improvement. Besides, a prototype tool to support the framework is introduced.
LA-iMageS: a software for elemental distribution bioimaging using LA-ICP-MS data.
López-Fernández, Hugo; de S Pessôa, Gustavo; Arruda, Marco A Z; Capelo-Martínez, José L; Fdez-Riverola, Florentino; Glez-Peña, Daniel; Reboiro-Jato, Miguel
2016-01-01
The spatial distribution of chemical elements in different types of samples is an important field in several research areas such as biology, paleontology or biomedicine, among others. Elemental distribution imaging by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an effective technique for qualitative and quantitative imaging due to its high spatial resolution and sensitivity. By applying this technique, vast amounts of raw data are generated to obtain high-quality images, essentially making the use of specific LA-ICP-MS imaging software that can process such data absolutely mandatory. Since existing solutions are usually commercial or hard-to-use for average users, this work introduces LA-iMageS, an open-source, free-to-use multiplatform application for fast and automatic generation of high-quality elemental distribution bioimages from LA-ICP-MS data in the PerkinElmer Elan XL format, whose results can be directly exported to external applications for further analysis. A key strength of LA-iMageS is its substantial added value for users, with particular regard to the customization of the elemental distribution bioimages, which allows, among other features, the ability to change color maps, increase image resolution or toggle between 2D and 3D visualizations.
Silveira, Augusta; Gonçalves, Joaquim; Sequeira, Teresa; Ribeiro, Cláudia; Lopes, Carlos; Monteiro, Eurico; Pimentel, Francisco Luís
2011-12-01
Quality of Life is a distinct and important emerging health focus, guiding practice and research. The routine Quality of Life evaluation in clinical, economic, and epidemiological studies and in medical practice promises a better Quality of Life and improved health resources optimization. The use of information technology and a Knowledge Management System related to Quality of Life assessment is essential to routine clinical evaluation and can define a clinical research methodology that is more efficient and better organized. In this paper, a Validation Model using the Quality of Life informatics platform is presented. Portuguese PC-software using European Organization for Research and Treatment of Cancer questionnaires (EORTC-QLQ C30 and EORTC-H&N35), is compared with the original paper-pen approach in the Quality of Life monitoring of head and neck cancer patients. The Quality of Life informatics platform was designed specifically for this study with a simple and intuitive interface that ensures confidentiality while providing Quality of Life evaluation for all cancer patients. For the Validation Model, the sample selection was random. Fifty-four head and neck cancer patients completed 216 questionnaires (108 using the informatics platform and 108 using the original paper-pen approach) with a one-hour interval in between. Patient preferences and computer experience were registered. Quality of Life informatics platform showed high usability as a user-friendly tool. This informatics platform allows data collection by auto-reply, database construction, and statistical data analysis and also facilitates the automatic listing of the questionnaires. When comparing the approaches (Wilcoxon test by item, percentile distribution and Cronbach's alpha), most of the responses were similar. Most of the patients (53.6%) reported a preference for the software version. The Quality of Life informatics platform has revealed to be a powerful and effective tool, allowing a real time analysis of Quality of Life data. Computer-based quality-of-life monitoring in head and neck cancer patients is essential to get clinically meaningful data that can support clinical decisions, identify potential needs, and support a stepped-care model. This represents a fundamental step for routine Quality of Life implementation in the Oncology Portuguese Institute (IPO-Porto), ORL and C&P department services clinical practice. Finally, we propose a diagram of diagnostic performance, considerating the generalized lack of mycological diagnosis in Portugal, which emphasizes the need for a careful history, focused on quantifying the latency period.
Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.
Anagnostopoulou, Pinelopi; Egger, Barbara; Lurà, Marco; Usemann, Jakob; Schmidt, Anne; Gorlanova, Olga; Korten, Insa; Roos, Markus; Frey, Urs; Latzin, Philipp
2016-03-01
Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing software settings. We analyzed best quality MBW measurements performed with an ultrasonic flowmeter in 24 infants from two centres in Switzerland with the current software settings. To challenge the robustness of these settings, we also used alternative analysis approaches. Using the current analysis software, the coefficient of variation (CV) for functional residual capacity (FRC) differed significantly between centres (mean ± SD (%): 9.8 ± 5.6 and 5.8 ± 2.9, respectively, p = 0.039). In addition, FRC values calculated during the washout differed between -25 and +30% from those of the washin of the same tracing. Results were mainly influenced by analysis settings and temperature recordings. Changing few algorithms resulted in significantly more robust analysis. Non-systematic inter-centre differences can be reduced by using correctly recorded environmental data and simple changes in the software algorithms. We provide implications that greatly improve infant MBW outcomes' quality and can be applied when multicentre trials are conducted.
Lee, JuneHyuck; Noh, Sang Do; Kim, Hyun-Jung; Kang, Yong-Shin
2018-01-01
The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS) perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT), artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry. PMID:29734699
An Introduction to Flight Software Development: FSW Today, FSW 2010
NASA Technical Reports Server (NTRS)
Gouvela, John
2004-01-01
Experience and knowledge gained from ongoing maintenance of Space Shuttle Flight Software and new development projects including Cockpit Avionics Upgrade are applied to projected needs of the National Space Exploration Vision through Spiral 2. Lessons learned from these current activities are applied to create a sustainable, reliable model for development of critical software to support Project Constellation. This presentation introduces the technologies, methodologies, and infrastructure needed to produce and sustain high quality software. It will propose what is needed to support a Vision for Space Exploration that places demands on the innovation and productivity needed to support future space exploration. The technologies in use today within FSW development include tools that provide requirements tracking, integrated change management, modeling and simulation software. Specific challenges that have been met include the introduction and integration of Commercial Off the Shelf (COTS) Real Time Operating System for critical functions. Though technology prediction has proved to be imprecise, Project Constellation requirements will need continued integration of new technology with evolving methodologies and changing project infrastructure. Targets for continued technology investment are integrated health monitoring and management, self healing software, standard payload interfaces, autonomous operation, and improvements in training. Emulation of the target hardware will also allow significant streamlining of development and testing. The methodologies in use today for FSW development are object oriented UML design, iterative development using independent components, as well as rapid prototyping . In addition, Lean Six Sigma and CMMI play a critical role in the quality and efficiency of the workforce processes. Over the next six years, we expect these methodologies to merge with other improvements into a consolidated office culture with all processes being guided by automated office assistants. The infrastructure in use today includes strict software development and configuration management procedures, including strong control of resource management and critical skills coverage. This will evolve to a fully integrated staff organization with efficient and effective communication throughout all levels guided by a Mission-Systems Architecture framework with focus on risk management and attention toward inevitable product obsolescence. This infrastructure of computing equipment, software and processes will itself be subject to technological change and need for management of change and improvement,
Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk
2017-10-11
Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.
Automated Diatom Analysis Applied to Traditional Light Microscopy: A Proof-of-Concept Study
NASA Astrophysics Data System (ADS)
Little, Z. H. L.; Bishop, I.; Spaulding, S. A.; Nelson, H.; Mahoney, C.
2017-12-01
Diatom identification and enumeration by high resolution light microscopy is required for many areas of research and water quality assessment. Such analyses, however, are both expertise and labor-intensive. These challenges motivate the need for an automated process to efficiently and accurately identify and enumerate diatoms. Improvements in particle analysis software have increased the likelihood that diatom enumeration can be automated. VisualSpreadsheet software provides a possible solution for automated particle analysis of high-resolution light microscope diatom images. We applied the software, independent of its complementary FlowCam hardware, to automated analysis of light microscope images containing diatoms. Through numerous trials, we arrived at threshold settings to correctly segment 67% of the total possible diatom valves and fragments from broad fields of view. (183 light microscope images were examined containing 255 diatom particles. Of the 255 diatom particles present, 216 diatoms valves and fragments of valves were processed, with 170 properly analyzed and focused upon by the software). Manual analysis of the images yielded 255 particles in 400 seconds, whereas the software yielded a total of 216 particles in 68 seconds, thus highlighting that the software has an approximate five-fold efficiency advantage in particle analysis time. As in past efforts, incomplete or incorrect recognition was found for images with multiple valves in contact or valves with little contrast. The software has potential to be an effective tool in assisting taxonomists with diatom enumeration by completing a large portion of analyses. Benefits and limitations of the approach are presented to allow for development of future work in image analysis and automated enumeration of traditional light microscope images containing diatoms.
NASA Astrophysics Data System (ADS)
Dervilllé, A.; Labrosse, A.; Zimmermann, Y.; Foucher, J.; Gronheid, R.; Boeckx, C.; Singh, A.; Leray, P.; Halder, S.
2016-03-01
The dimensional scaling in IC manufacturing strongly drives the demands on CD and defect metrology techniques and their measurement uncertainties. Defect review has become as important as CD metrology and both of them create a new metrology paradigm because it creates a completely new need for flexible, robust and scalable metrology software. Current, software architectures and metrology algorithms are performant but it must be pushed to another higher level in order to follow roadmap speed and requirements. For example: manage defect and CD in one step algorithm, customize algorithms and outputs features for each R&D team environment, provide software update every day or every week for R&D teams in order to explore easily various development strategies. The final goal is to avoid spending hours and days to manually tune algorithm to analyze metrology data and to allow R&D teams to stay focus on their expertise. The benefits are drastic costs reduction, more efficient R&D team and better process quality. In this paper, we propose a new generation of software platform and development infrastructure which can integrate specific metrology business modules. For example, we will show the integration of a chemistry module dedicated to electronics materials like Direct Self Assembly features. We will show a new generation of image analysis algorithms which are able to manage at the same time defect rates, images classifications, CD and roughness measurements with high throughput performances in order to be compatible with HVM. In a second part, we will assess the reliability, the customization of algorithm and the software platform capabilities to follow new specific semiconductor metrology software requirements: flexibility, robustness, high throughput and scalability. Finally, we will demonstrate how such environment has allowed a drastic reduction of data analysis cycle time.
The National Library of Medicine Pill Image Recognition Challenge: An Initial Report.
Yaniv, Ziv; Faruque, Jessica; Howe, Sally; Dunn, Kathel; Sharlip, David; Bond, Andrew; Perillan, Pablo; Bodenreider, Olivier; Ackerman, Michael J; Yoo, Terry S
2016-10-01
In January 2016 the U.S. National Library of Medicine announced a challenge competition calling for the development and discovery of high-quality algorithms and software that rank how well consumer images of prescription pills match reference images of pills in its authoritative RxIMAGE collection. This challenge was motivated by the need to easily identify unknown prescription pills both by healthcare personnel and the general public. Potential benefits of this capability include confirmation of the pill in settings where the documentation and medication have been separated, such as in a disaster or emergency; and confirmation of a pill when the prescribed medication changes from brand to generic, or for any other reason the shape and color of the pill change. The data for the competition consisted of two types of images, high quality macro photographs, reference images, and consumer quality photographs of the quality we expect users of a proposed application to acquire. A training dataset consisting of 2000 reference images and 5000 corresponding consumer quality images acquired from 1000 pills was provided to challenge participants. A second dataset acquired from 1000 pills with similar distributions of shape and color was reserved as a segregated testing set. Challenge submissions were required to produce a ranking of the reference images, given a consumer quality image as input. Determination of the winning teams was done using the mean average precision quality metric, with the three winners obtaining mean average precision scores of 0.27, 0.09, and 0.08. In the retrieval results, the correct image was amongst the top five ranked images 43%, 12%, and 11% of the time, out of 5000 query/consumer images. This is an initial promising step towards development of an NLM software system and application-programming interface facilitating pill identification. The training dataset will continue to be freely available online at: http://pir.nlm.nih.gov/challenge/submission.html.
SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, S; Mehta, V
Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoringmore » function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.« less
Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnstone, Chris; Bazalova-Carter, Magdalena
Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional datamore » sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.« less
Ochs, Christopher; Geller, James; Perl, Yehoshua; Musen, Mark A.
2016-01-01
Software tools play a critical role in the development and maintenance of biomedical ontologies. One important task that is difficult without software tools is ontology quality assurance. In previous work, we have introduced different kinds of abstraction networks to provide a theoretical foundation for ontology quality assurance tools. Abstraction networks summarize the structure and content of ontologies. One kind of abstraction network that we have used repeatedly to support ontology quality assurance is the partial-area taxonomy. It summarizes structurally and semantically similar concepts within an ontology. However, the use of partial-area taxonomies was ad hoc and not generalizable. In this paper, we describe the Ontology Abstraction Framework (OAF), a unified framework and software system for deriving, visualizing, and exploring partial-area taxonomy abstraction networks. The OAF includes support for various ontology representations (e.g., OWL and SNOMED CT's relational format). A Protégé plugin for deriving “live partial-area taxonomies” is demonstrated. PMID:27345947
Ochs, Christopher; Geller, James; Perl, Yehoshua; Musen, Mark A
2016-08-01
Software tools play a critical role in the development and maintenance of biomedical ontologies. One important task that is difficult without software tools is ontology quality assurance. In previous work, we have introduced different kinds of abstraction networks to provide a theoretical foundation for ontology quality assurance tools. Abstraction networks summarize the structure and content of ontologies. One kind of abstraction network that we have used repeatedly to support ontology quality assurance is the partial-area taxonomy. It summarizes structurally and semantically similar concepts within an ontology. However, the use of partial-area taxonomies was ad hoc and not generalizable. In this paper, we describe the Ontology Abstraction Framework (OAF), a unified framework and software system for deriving, visualizing, and exploring partial-area taxonomy abstraction networks. The OAF includes support for various ontology representations (e.g., OWL and SNOMED CT's relational format). A Protégé plugin for deriving "live partial-area taxonomies" is demonstrated. Copyright © 2016 Elsevier Inc. All rights reserved.
IEEE Computer Society/Software Engineering Institute Software Process Achievement (SPA) Award 2009
2011-03-01
capabilities to our GDM. We also introduced software as a service ( SaaS ) as part our technology solutions and have further enhanced our ability to...model PROSPER Infosys production support methodology Q&P quality and productivity R&D research and development SaaS software as a service ... Software Development Life Cycle (SDLC) 23 Table 10: Scientific Estimation Coverage by Service Line 27 CMU/SEI-2011-TR-008 | vi CMU/SEI-2011
High speed micromachining with high power UV laser
NASA Astrophysics Data System (ADS)
Patel, Rajesh S.; Bovatsek, James M.
2013-03-01
Increasing demand for creating fine features with high accuracy in manufacturing of electronic mobile devices has fueled growth for lasers in manufacturing. High power, high repetition rate ultraviolet (UV) lasers provide an opportunity to implement a cost effective high quality, high throughput micromachining process in a 24/7 manufacturing environment. The energy available per pulse and the pulse repetition frequency (PRF) of diode pumped solid state (DPSS) nanosecond UV lasers have increased steadily over the years. Efficient use of the available energy from a laser is important to generate accurate fine features at a high speed with high quality. To achieve maximum material removal and minimal thermal damage for any laser micromachining application, use of the optimal process parameters including energy density or fluence (J/cm2), pulse width, and repetition rate is important. In this study we present a new high power, high PRF QuasarR 355-40 laser from Spectra-Physics with TimeShiftTM technology for unique software adjustable pulse width, pulse splitting, and pulse shaping capabilities. The benefits of these features for micromachining include improved throughput and quality. Specific example and results of silicon scribing are described to demonstrate the processing benefits of the Quasar's available power, PRF, and TimeShift technology.
Open Source Molecular Modeling
Pirhadi, Somayeh; Sunseri, Jocelyn; Koes, David Ryan
2016-01-01
The success of molecular modeling and computational chemistry efforts are, by definition, dependent on quality software applications. Open source software development provides many advantages to users of modeling applications, not the least of which is that the software is free and completely extendable. In this review we categorize, enumerate, and describe available open source software packages for molecular modeling and computational chemistry. PMID:27631126
ERIC Educational Resources Information Center
Weston, Mark E.; Bain, Alan
2015-01-01
This study reports findings from a matched-comparison, repeated-measure for intact groups design of the mediating effect of a suite of software on the quality of classroom instruction provided to students by teachers. The quality of instruction provided by teachers in the treatment and control groups was documented via observations that were…
Software Quality Assurance and Verification for the MPACT Library Generation Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yuxuan; Williams, Mark L.; Wiarda, Dorothea
This report fulfills the requirements for the Consortium for the Advanced Simulation of Light-Water Reactors (CASL) milestone L2:RTM.P14.02, “SQA and Verification for MPACT Library Generation,” by documenting the current status of the software quality, verification, and acceptance testing of nuclear data libraries for MPACT. It provides a brief overview of the library generation process, from general-purpose evaluated nuclear data files (ENDF/B) to a problem-dependent cross section library for modeling of light-water reactors (LWRs). The software quality assurance (SQA) programs associated with each of the software used to generate the nuclear data libraries are discussed; specific tests within the SCALE/AMPX andmore » VERA/XSTools repositories are described. The methods and associated tests to verify the quality of the library during the generation process are described in detail. The library generation process has been automated to a degree to (1) ensure that it can be run without user intervention and (2) to ensure that the library can be reproduced. Finally, the acceptance testing process that will be performed by representatives from the Radiation Transport Methods (RTM) Focus Area prior to the production library’s release is described in detail.« less
Assessment of three different software systems in the evaluation of dynamic MRI of the breast.
Kurz, K D; Steinhaus, D; Klar, V; Cohnen, M; Wittsack, H J; Saleh, A; Mödder, U; Blondin, D
2009-02-01
The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ("CADstream" and "3TP") and one self-developed software system ("Mammatool"). Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. "CADstream" showed the best score on subjective quality criteria. "3TP" showed the lowest number of false-positive results. "Mammatool" produced the lowest number of benign tissues indicated with parametric overlay. All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable.
Reuse Metrics for Object Oriented Software
NASA Technical Reports Server (NTRS)
Bieman, James M.
1998-01-01
One way to increase the quality of software products and the productivity of software development is to reuse existing software components when building new software systems. In order to monitor improvements in reuse, the level of reuse must be measured. In this NASA supported project we (1) derived a suite of metrics which quantify reuse attributes for object oriented, object based, and procedural software, (2) designed prototype tools to take these measurements in Ada, C++, Java, and C software, (3) evaluated the reuse in available software, (4) analyzed the relationship between coupling, cohesion, inheritance, and reuse, (5) collected object oriented software systems for our empirical analyses, and (6) developed quantitative criteria and methods for restructuring software to improve reusability.
Learning Photogrammetry with Interactive Software Tool PhoX
NASA Astrophysics Data System (ADS)
Luhmann, T.
2016-06-01
Photogrammetry is a complex topic in high-level university teaching, especially in the fields of geodesy, geoinformatics and metrology where high quality results are demanded. In addition, more and more black-box solutions for 3D image processing and point cloud generation are available that generate nice results easily, e.g. by structure-from-motion approaches. Within this context, the classical approach of teaching photogrammetry (e.g. focusing on aerial stereophotogrammetry) has to be reformed in order to educate students and professionals with new topics and provide them with more information behind the scene. Since around 20 years photogrammetry courses at the Jade University of Applied Sciences in Oldenburg, Germany, include the use of digital photogrammetry software that provide individual exercises, deep analysis of calculation results and a wide range of visualization tools for almost all standard tasks in photogrammetry. During the last years the software package PhoX has been developed that is part of a new didactic concept in photogrammetry and related subjects. It also serves as analysis tool in recent research projects. PhoX consists of a project-oriented data structure for images, image data, measured points and features and 3D objects. It allows for almost all basic photogrammetric measurement tools, image processing, calculation methods, graphical analysis functions, simulations and much more. Students use the program in order to conduct predefined exercises where they have the opportunity to analyse results in a high level of detail. This includes the analysis of statistical quality parameters but also the meaning of transformation parameters, rotation matrices, calibration and orientation data. As one specific advantage, PhoX allows for the interactive modification of single parameters and the direct view of the resulting effect in image or object space.
IDEAL: Images Across Domains, Experiments, Algorithms and Learning
NASA Astrophysics Data System (ADS)
Ushizima, Daniela M.; Bale, Hrishikesh A.; Bethel, E. Wes; Ercius, Peter; Helms, Brett A.; Krishnan, Harinarayan; Grinberg, Lea T.; Haranczyk, Maciej; Macdowell, Alastair A.; Odziomek, Katarzyna; Parkinson, Dilworth Y.; Perciano, Talita; Ritchie, Robert O.; Yang, Chao
2016-11-01
Research across science domains is increasingly reliant on image-centric data. Software tools are in high demand to uncover relevant, but hidden, information in digital images, such as those coming from faster next generation high-throughput imaging platforms. The challenge is to analyze the data torrent generated by the advanced instruments efficiently, and provide insights such as measurements for decision-making. In this paper, we overview work performed by an interdisciplinary team of computational and materials scientists, aimed at designing software applications and coordinating research efforts connecting (1) emerging algorithms for dealing with large and complex datasets; (2) data analysis methods with emphasis in pattern recognition and machine learning; and (3) advances in evolving computer architectures. Engineering tools around these efforts accelerate the analyses of image-based recordings, improve reusability and reproducibility, scale scientific procedures by reducing time between experiments, increase efficiency, and open opportunities for more users of the imaging facilities. This paper describes our algorithms and software tools, showing results across image scales, demonstrating how our framework plays a role in improving image understanding for quality control of existent materials and discovery of new compounds.
The role of open-source software in innovation and standardization in radiology.
Erickson, Bradley J; Langer, Steve; Nagy, Paul
2005-11-01
The use of open-source software (OSS), in which developers release the source code to applications they have developed, is popular in the software industry. This is done to allow others to modify and improve software (which may or may not be shared back to the community) and to allow others to learn from the software. Radiology was an early participant in this model, supporting OSS that implemented the ACR-National Electrical Manufacturers Association (now Digital Imaging and Communications in Medicine) standard for medical image communications. In radiology and in other fields, OSS has promoted innovation and the adoption of standards. Popular OSS is of high quality because access to source code allows many people to identify and resolve errors. Open-source software is analogous to the peer-review scientific process: one must be able to see and reproduce results to understand and promote what is shared. The authors emphasize that support for OSS need not threaten vendors; most vendors embrace and benefit from standards. Open-source development does not replace vendors but more clearly defines their roles, typically focusing on areas in which proprietary differentiators benefit customers and on professional services such as implementation planning and service. Continued support for OSS is essential for the success of our field.
Lott, Gus K; Johnson, Bruce R; Bonow, Robert H; Land, Bruce R; Hoy, Ronald R
2009-01-01
We present g-PRIME, a software based tool for physiology data acquisition, analysis, and stimulus generation in education and research. This software was developed in an undergraduate neurophysiology course and strongly influenced by instructor and student feedback. g-PRIME is a free, stand-alone, windows application coded and "compiled" in Matlab (does not require a Matlab license). g-PRIME supports many data acquisition interfaces from the PC sound card to expensive high throughput calibrated equipment. The program is designed as a software oscilloscope with standard trigger modes, multi-channel visualization controls, and data logging features. Extensive analysis options allow real time and offline filtering of signals, multi-parameter threshold-and-window based event detection, and two-dimensional display of a variety of parameters including event time, energy density, maximum FFT frequency component, max/min amplitudes, and inter-event rate and intervals. The software also correlates detected events with another simultaneously acquired source (event triggered average) in real time or offline. g-PRIME supports parameter histogram production and a variety of elegant publication quality graphics outputs. A major goal of this software is to merge powerful engineering acquisition and analysis tools with a biological approach to studies of nervous system function.
Mining dynamic noteworthy functions in software execution sequences
Huang, Guoyan; Wang, Yuqian; He, Haitao; Ren, Jiadong
2017-01-01
As the quality of crucial entities can directly affect that of software, their identification and protection become an important premise for effective software development, management, maintenance and testing, which thus contribute to improving the software quality and its attack-defending ability. Most analysis and evaluation on important entities like codes-based static structure analysis are on the destruction of the actual software running. In this paper, from the perspective of software execution process, we proposed an approach to mine dynamic noteworthy functions (DNFM)in software execution sequences. First, according to software decompiling and tracking stack changes, the execution traces composed of a series of function addresses were acquired. Then these traces were modeled as execution sequences and then simplified so as to get simplified sequences (SFS), followed by the extraction of patterns through pattern extraction (PE) algorithm from SFS. After that, evaluating indicators inner-importance and inter-importance were designed to measure the noteworthiness of functions in DNFM algorithm. Finally, these functions were sorted by their noteworthiness. Comparison and contrast were conducted on the experiment results from two traditional complex network-based node mining methods, namely PageRank and DegreeRank. The results show that the DNFM method can mine noteworthy functions in software effectively and precisely. PMID:28278276
Ohta, Tazro; Nakazato, Takeru; Bono, Hidemasa
2017-06-01
It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. © The Authors 2017. Published by Oxford University Press.
2015-01-01
We report the implementation of high-quality signal processing algorithms into ProteoWizard, an efficient, open-source software package designed for analyzing proteomics tandem mass spectrometry data. Specifically, a new wavelet-based peak-picker (CantWaiT) and a precursor charge determination algorithm (Turbocharger) have been implemented. These additions into ProteoWizard provide universal tools that are independent of vendor platform for tandem mass spectrometry analyses and have particular utility for intralaboratory studies requiring the advantages of different platforms convergent on a particular workflow or for interlaboratory investigations spanning multiple platforms. We compared results from these tools to those obtained using vendor and commercial software, finding that in all cases our algorithms resulted in a comparable number of identified peptides for simple and complex samples measured on Waters, Agilent, and AB SCIEX quadrupole time-of-flight and Thermo Q-Exactive mass spectrometers. The mass accuracy of matched precursor ions also compared favorably with vendor and commercial tools. Additionally, typical analysis runtimes (∼1–100 ms per MS/MS spectrum) were short enough to enable the practical use of these high-quality signal processing tools for large clinical and research data sets. PMID:25411686
French, William R; Zimmerman, Lisa J; Schilling, Birgit; Gibson, Bradford W; Miller, Christine A; Townsend, R Reid; Sherrod, Stacy D; Goodwin, Cody R; McLean, John A; Tabb, David L
2015-02-06
We report the implementation of high-quality signal processing algorithms into ProteoWizard, an efficient, open-source software package designed for analyzing proteomics tandem mass spectrometry data. Specifically, a new wavelet-based peak-picker (CantWaiT) and a precursor charge determination algorithm (Turbocharger) have been implemented. These additions into ProteoWizard provide universal tools that are independent of vendor platform for tandem mass spectrometry analyses and have particular utility for intralaboratory studies requiring the advantages of different platforms convergent on a particular workflow or for interlaboratory investigations spanning multiple platforms. We compared results from these tools to those obtained using vendor and commercial software, finding that in all cases our algorithms resulted in a comparable number of identified peptides for simple and complex samples measured on Waters, Agilent, and AB SCIEX quadrupole time-of-flight and Thermo Q-Exactive mass spectrometers. The mass accuracy of matched precursor ions also compared favorably with vendor and commercial tools. Additionally, typical analysis runtimes (∼1-100 ms per MS/MS spectrum) were short enough to enable the practical use of these high-quality signal processing tools for large clinical and research data sets.
An assessment of a film enhancement system for use in a radiation therapy department.
Solowsky, E L; Reinstein, L E; Meek, A G
1990-01-01
The clinical uses of a radiotherapy film enhancement system are explored. The primary functions of the system are to improve the quality of poorly exposed simulator and portal films, and to perform comparisons between the two films to determine whether patient or block positioning errors are present. Other features include: the production of inexpensive, high quality hardcopy images of simulation films and initial portal films for chart documentation, the capacity to overlay lateral simulation films with sagittal MRI films to aid in field design, and a mode to zoom in on individual CT or MRI images and enlarge them for video display during chart rounds or instructional sessions. This commercially available system is comprised of a microcomputer, frame grabber, CCD camera with zoom lens, and a high-resolution thermal printer. The user-friendly software is menu driven and utilizes both keyboard and track ball to perform its functions. At the heart of the software is a very fast Adaptive Histogram Equalization (AHE) routine, which enhances and improves the readability of most portal films. The system has been evaluated for several disease sites, and its advantages and limitations will be presented.
Clinical research in a hospital--from the lone rider to teamwork.
Hannisdal, E
1996-01-01
Clinical research of high international standard is very demanding and requires clinical data of high quality, software, hardware and competence in research design and statistical treatment of data. Most busy clinicians have little time allocated for clinical research and this increases the need for a potent infrastructure. This paper describes how the Norwegian Radium Hospital, a specialized cancer hospital, has reorganized the clinical research process. This includes a new department, the Clinical Research Office, which serves the formal framework, a central Diagnosis Registry, clinical databases and multicentre studies. The department assists about 120 users, mainly clinicians. Installation of a network software package with over 10 programs has strongly provided an internal standardization, reduced the costs and saved clinicians a great deal of time. The hospital is building up about 40 diagnosis-specific clinical databases with up to 200 variables registered. These databases are shared by the treatment group and seem to be important tools for quality assurance. We conclude that the clinical research process benefits from a firm infrastructure facilitating teamwork through extensive use of modern information technology. We are now ready for the next phase, which is to work for a better external technical framework for cooperation with other institutions throughout the world.
ERIC Educational Resources Information Center
Holcomb, Glenda S.
2010-01-01
This qualitative, phenomenological doctoral dissertation research study explored the software project team members perceptions of changing organizational cultures based on management decisions made at project deviation points. The research study provided a view into challenged or failing government software projects through the lived experiences…
A novel approach to TEM preparation with a (7-axis stage) triple-beam FIB-SEM system
NASA Astrophysics Data System (ADS)
Clarke, Jamil J.
2015-10-01
Preparation of lamellae from bulk to grid for Cs-corrected Transmission Electron Microscope (TEM) observation has mostly become routine work on the latest FIB-SEM systems, with standardized techniques that often are left to automation for the initial steps. The finalization of lamellae however, has mostly become, non-routine, non-repeatable and often driven by user experience level in most cases to produce high quality damage-less cross section. Materials processing of the latest technologies, with ever-shrinking Nano-sized structures pose challenges to modern FIB-SEM systems. This can often lead to specialized techniques and hyper-specific functions for producing ultra-thin high quality lamellae that often are lab specific, preventing practical use of such techniques across multiple materials and applications. Several factors that should be incorporated in processing fine structured materials successfully include how the use of electron and ion scan conditions can affect a thin section during ion milling, the type of ion species applied for material processing during the finalization of lamellae with gallium ions or of a smaller ion species type such as Ar/Xe, sample orientation of the lamella during the thinning process which is linked to ion beam incident angle as a direct relationship in the creation of waterfall effects or curtain effects, and how software can be employed to aid in the reduction of these artifacts with reproducible results regardless of FIB-SEM experience for site-specific lift outs. A traditional TEM preparation was performed of a fine structure specimen in pursuit of a process technique to produce a high quality TEM lamella which would address all of the factors mentioned. These new capabilities have been refined and improved upon during the FIB-SEM design and development stages with an end result of a new approach that yields an improvement in quality by the reduction of common ion milling artifacts such as curtain effects, amorphous material, and better pin pointing of the area of interest while reducing overall processing time for the TEM sample preparation process and enhancing repeatability through ease of use via software controls. The development of these new technologies, incorporating a third Ar/Xe ion beam column in conjunction with the electron and gallium ion beam column, a 7-axis stage for enhanced sample orientation with tilt functions in two axes and automated swing control along with a host of additional functions which address the factors aforementioned such as electron and ion scan techniques and curtain effect removal by the use of hardware and software components that are key to reduce typical FIB related artifacts, all of which are called "ACE [Anti Curtaining Effect] Technologies" are explained. The overall developments of these technologies are to address a significant point that productivity, throughput and repeatability are comprised by synergy between the user, application, software and hardware within a FIB-SEM system. The latest Hitachi FIB-SEM platform offers these innovations for reliability, repeatability and high quality lamella preparation for Cs-corrected (S)TEMs.
Geoinformatics 2007: data to knowledge
Brady, Shailaja R.; Sinha, A. Krishna; Gundersen, Linda C.
2007-01-01
Geoinformatics is the term used to describe a variety of efforts to promote collaboration between the computer sciences and the geosciences to solve complex scientific questions. It refers to the distributed, integrated digital information system and working environment that provides innovative means for the study of the Earth systems, as well as other planets, through use of advanced information technologies. Geoinformatics activities range from major research and development efforts creating new technologies to provide high-quality, sustained production-level services for data discovery, integration and analysis, to small, discipline-specific efforts that develop earth science data collections and data analysis tools serving the needs of individual communities. The ultimate vision of Geoinformatics is a highly interconnected data system populated with high quality, freely available data, as well as, a robust set of software for analysis, visualization, and modeling.
Klang River water quality modelling using music
NASA Astrophysics Data System (ADS)
Zahari, Nazirul Mubin; Zawawi, Mohd Hafiz; Muda, Zakaria Che; Sidek, Lariyah Mohd; Fauzi, Nurfazila Mohd; Othman, Mohd Edzham Fareez; Ahmad, Zulkepply
2017-09-01
Water is an essential resource that sustains life on earth; changes in the natural quality and distribution of water have ecological impacts that can sometimes be devastating. Recently, Malaysia is facing many environmental issues regarding water pollution. The main causes of river pollution are rapid urbanization, arising from the development of residential, commercial, industrial sites, infrastructural facilities and others. The purpose of the study was to predict the water quality of the Connaught Bridge Power Station (CBPS), Klang River. Besides that, affects to the low tide and high tide and. to forecast the pollutant concentrations of the Biochemical Oxygen Demand (BOD) and Total Suspended Solid (TSS) for existing land use of the catchment area through water quality modeling (by using the MUSIC software). Besides that, to identifying an integrated urban stormwater treatment system (Best Management Practice or BMPs) to achieve optimal performance in improving the water quality of the catchment using the MUSIC software in catchment areas having tropical climates. Result from MUSIC Model such as BOD5 at station 1 can be reduce the concentration from Class IV to become Class III. Whereas, for TSS concentration from Class III to become Class II at the station 1. The model predicted a mean TSS reduction of 0.17%, TP reduction of 0.14%, TN reduction of 0.48% and BOD5 reduction of 0.31% for Station 1 Thus, from the result after purposed BMPs the water quality is safe to use because basically water quality monitoring is important due to threat such as activities are harmful to aquatic organisms and public health.
NASA Astrophysics Data System (ADS)
Sharma, Amita; Sarangdevot, S. S.
2010-11-01
Aspect-Oriented Programming (AOP) methodology has been investigated in development of real world business application software—Financial Accounting Software. Eclipse-AJDT environment has been used as open source enhanced IDE support for programming in AOP language—Aspect J. Crosscutting concerns have been identified and modularized as aspects. This reduces the complexity of the design considerably due to elimination of code scattering and tangling. Improvement in modularity, quality and performance is achieved. The study concludes that AOP methodology in Eclipse-AJDT environment offers powerful support for modular design and implementation of real world quality business software.
NASA Astrophysics Data System (ADS)
The subjects discussed are related to LSI/VLSI based subscriber transmission and customer access for the Integrated Services Digital Network (ISDN), special applications of fiber optics, ISDN and competitive telecommunication services, technical preparations for the Geostationary-Satellite Orbit Conference, high-capacity statistical switching fabrics, networking and distributed systems software, adaptive arrays and cancelers, synchronization and tracking, speech processing, advances in communication terminals, full-color videotex, and a performance analysis of protocols. Advances in data communications are considered along with transmission network plans and progress, direct broadcast satellite systems, packet radio system aspects, radio-new and developing technologies and applications, the management of software quality, and Open Systems Interconnection (OSI) aspects of telematic services. Attention is given to personal computers and OSI, the role of software reliability measurement in information systems, and an active array antenna for the next-generation direct broadcast satellite.
Measuring Software Product Quality: The ISO 25000 Series and CMMI
2004-06-14
performance objectives” covers objectives and requirements for product quality, service quality , and process performance. Process performance objectives...such that product quality, service quality , and process performance attributes are measurable and controlled throughout the project (internal and
Multiphysical simulation analysis of the dislocation structure in germanium single crystals
NASA Astrophysics Data System (ADS)
Podkopaev, O. I.; Artemyev, V. V.; Smirnov, A. D.; Mamedov, V. M.; Sid'ko, A. P.; Kalaev, V. V.; Kravtsova, E. D.; Shimanskii, A. F.
2016-09-01
To grow high-quality germanium crystals is one of the most important problems of growth industry. The dislocation density is an important parameter of the quality of single crystals. The dislocation densities in germanium crystals 100 mm in diameter, which have various shapes of the side surface and are grown by the Czochralski technique, are experimentally measured. The crystal growth is numerically simulated using heat-transfer and hydrodynamics models and the Alexander-Haasen dislocation model in terms of the CGSim software package. A comparison of the experimental and calculated dislocation densities shows that the dislocation model can be applied to study lattice defects in germanium crystals and to improve their quality.
NASA Technical Reports Server (NTRS)
Leveson, Nancy
1987-01-01
Software safety and its relationship to other qualities are discussed. It is shown that standard reliability and fault tolerance techniques will not solve the safety problem for the present. A new attitude requires: looking at what you do NOT want software to do along with what you want it to do; and assuming things will go wrong. New procedures and changes to entire software development process are necessary: special software safety analysis techniques are needed; and design techniques, especially eliminating complexity, can be very helpful.
Software engineering project management - A state-of-the-art report
NASA Technical Reports Server (NTRS)
Thayer, R. H.; Lehman, J. H.
1977-01-01
The management of software engineering projects in the aerospace industry was investigated. The survey assessed such features as contract type, specification preparation techniques, software documentation required by customers, planning and cost-estimating, quality control, the use of advanced program practices, software tools and test procedures, the education levels of project managers, programmers and analysts, work assignment, automatic software monitoring capabilities, design and coding reviews, production times, success rates, and organizational structure of the projects.
Software Reuse Within the Earth Science Community
NASA Technical Reports Server (NTRS)
Marshall, James J.; Olding, Steve; Wolfe, Robert E.; Delnore, Victor E.
2006-01-01
Scientific missions in the Earth sciences frequently require cost-effective, highly reliable, and easy-to-use software, which can be a challenge for software developers to provide. The NASA Earth Science Enterprise (ESE) spends a significant amount of resources developing software components and other software development artifacts that may also be of value if reused in other projects requiring similar functionality. In general, software reuse is often defined as utilizing existing software artifacts. Software reuse can improve productivity and quality while decreasing the cost of software development, as documented by case studies in the literature. Since large software systems are often the results of the integration of many smaller and sometimes reusable components, ensuring reusability of such software components becomes a necessity. Indeed, designing software components with reusability as a requirement can increase the software reuse potential within a community such as the NASA ESE community. The NASA Earth Science Data Systems (ESDS) Software Reuse Working Group is chartered to oversee the development of a process that will maximize the reuse potential of existing software components while recommending strategies for maximizing the reusability potential of yet-to-be-designed components. As part of this work, two surveys of the Earth science community were conducted. The first was performed in 2004 and distributed among government employees and contractors. A follow-up survey was performed in 2005 and distributed among a wider community, to include members of industry and academia. The surveys were designed to collect information on subjects such as the current software reuse practices of Earth science software developers, why they choose to reuse software, and what perceived barriers prevent them from reusing software. In this paper, we compare the results of these surveys, summarize the observed trends, and discuss the findings. The results are very similar, with the second, larger survey confirming the basic results of the first, smaller survey. The results suggest that reuse of ESE software can drive down the cost and time of system development, increase flexibility and responsiveness of these systems to new technologies and requirements, and increase effective and accountable community participation.
Assurance Evaluation for OSS Adoption in a Telco Context
NASA Astrophysics Data System (ADS)
Ardagna, Claudio A.; Banzi, Massimo; Damiani, Ernesto; El Ioini, Nabil; Frati, Fulvio
Software Assurance (SwA) is a complex concept that involves different stages of a software development process and may be defined differently depending on its focus, as for instance software quality, security, or dependability. In Computer Science, the term assurance is referred to all activities necessary to provide enough confidence that a software product will satisfy its users’ functional and non-functional requirements.
Developing Confidence Limits For Reliability Of Software
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J.
1991-01-01
Technique developed for estimating reliability of software by use of Moranda geometric de-eutrophication model. Pivotal method enables straightforward construction of exact bounds with associated degree of statistical confidence about reliability of software. Confidence limits thus derived provide precise means of assessing quality of software. Limits take into account number of bugs found while testing and effects of sampling variation associated with random order of discovering bugs.
Socio-Cultural Challenges in Global Software Engineering Education
ERIC Educational Resources Information Center
Hoda, Rashina; Babar, Muhammad Ali; Shastri, Yogeshwar; Yaqoob, Humaa
2017-01-01
Global software engineering education (GSEE) is aimed at providing software engineering (SE) students with knowledge, skills, and understanding of working in globally distributed arrangements so they can be prepared for the global SE (GSE) paradigm. It is important to understand the challenges involved in GSEE for improving the quality and…
Multidisciplinary and Active/Collaborative Approaches in Teaching Requirements Engineering
ERIC Educational Resources Information Center
Rosca, Daniela
2005-01-01
The requirements engineering course is a core component of the curriculum for the Master's in Software Engineering programme, at Monmouth University (MU). It covers the process, methods and tools specific to this area, together with the corresponding software quality issues. The need to produce software engineers with strong teamwork and…
Data Quality Monitoring System for New GEM Muon Detectors for the CMS Experiment Upgrade
NASA Astrophysics Data System (ADS)
King, Robert; CMS Muon Group Team
2017-01-01
The Gas Electron Multiplier (GEM) detectors are novel detectors designed to improve the muon trigger and tracking performance in CMS experiment for the high luminosity upgrade of the LHC. Partial installation of GEM detectors is planned during the 2016-2017 technical stop. Before the GEM system is installed underground, its data acquisition (DAQ) electronics must be thoroughly tested. The DAQ system includes several commercial and custom-built electronic boards running custom firmware. The front-end electronics are radiation-hard and communicate via optical fibers. The data quality monitoring (DQM) software framework has been designed to provide online verification of the integrity of the data produced by the detector electronics, and to promptly identify potential hardware or firmware malfunctions in the system. Local hits reconstruction and clustering algorithms allow quality control of the data produced by each GEM chamber. Once the new detectors are installed, the DQM will monitor the stability and performance of the system during normal data-taking operations. We discuss the design of the DQM system, the software being developed to read out and process the detector data, and the methods used to identify and report hardware and firmware malfunctions of the system.
Introduction of software tools for epidemiological surveillance in infection control in Colombia
Motoa, Gabriel; Vallejo, Marta; Blanco, Víctor M; Correa, Adriana; de la Cadena, Elsa; Villegas, María Virginia
2015-01-01
Introduction: Healthcare-Associated Infections (HAI) are a challenge for patient safety in the hospitals. Infection control committees (ICC) should follow CDC definitions when monitoring HAI. The handmade method of epidemiological surveillance (ES) may affect the sensitivity and specificity of the monitoring system, while electronic surveillance can improve the performance, quality and traceability of recorded information. Objective: To assess the implementation of a strategy for electronic surveillance of HAI, Bacterial Resistance and Antimicrobial Consumption by the ICC of 23 high-complexity clinics and hospitals in Colombia, during the period 2012-2013. Methods: An observational study evaluating the introduction of electronic tools in the ICC was performed; we evaluated the structure and operation of the ICC, the degree of incorporation of the software HAI Solutions and the adherence to record the required information. Results: Thirty-eight percent of hospitals (8/23) had active surveillance strategies with standard criteria of the CDC, and 87% of institutions adhered to the module of identification of cases using the HAI Solutions software. In contrast, compliance with the diligence of the risk factors for device-associated HAIs was 33%. Conclusions: The introduction of ES could achieve greater adherence to a model of active surveillance, standardized and prospective, helping to improve the validity and quality of the recorded information. PMID:26309340
Introduction of software tools for epidemiological surveillance in infection control in Colombia.
Hernández-Gómez, Cristhian; Motoa, Gabriel; Vallejo, Marta; Blanco, Víctor M; Correa, Adriana; de la Cadena, Elsa; Villegas, María Virginia
2015-01-01
Healthcare-Associated Infections (HAI) are a challenge for patient safety in the hospitals. Infection control committees (ICC) should follow CDC definitions when monitoring HAI. The handmade method of epidemiological surveillance (ES) may affect the sensitivity and specificity of the monitoring system, while electronic surveillance can improve the performance, quality and traceability of recorded information. To assess the implementation of a strategy for electronic surveillance of HAI, Bacterial Resistance and Antimicrobial Consumption by the ICC of 23 high-complexity clinics and hospitals in Colombia, during the period 2012-2013. An observational study evaluating the introduction of electronic tools in the ICC was performed; we evaluated the structure and operation of the ICC, the degree of incorporation of the software HAI Solutions and the adherence to record the required information. Thirty-eight percent of hospitals (8/23) had active surveillance strategies with standard criteria of the CDC, and 87% of institutions adhered to the module of identification of cases using the HAI Solutions software. In contrast, compliance with the diligence of the risk factors for device-associated HAIs was 33%. The introduction of ES could achieve greater adherence to a model of active surveillance, standardized and prospective, helping to improve the validity and quality of the recorded information.
Haase, Rocco; Wunderlich, Maria; Dillenseger, Anja; Kern, Raimar; Akgün, Katja; Ziemssen, Tjalf
2018-04-01
For safety evaluation, randomized controlled trials (RCTs) are not fully able to identify rare adverse events. The richest source of safety data lies in the post-marketing phase. Real-world evidence (RWE) and observational studies are becoming increasingly popular because they reflect usefulness of drugs in real life and have the ability to discover uncommon or rare adverse drug reactions. Areas covered: Adding the documentation of psychological symptoms and other medical disciplines, the necessity for a complex documentation becomes apparent. The collection of high-quality data sets in clinical practice requires the use of special documentation software as the quality of data in RWE studies can be an issue in contrast to the data obtained from RCTs. The MSDS3D software combines documentation of patient data with patient management of patients with multiple sclerosis. Following a continuous development over several treatment-specific modules, we improved and expanded the realization of safety management in MSDS3D with regard to the characteristics of different treatments and populations. Expert opinion: eHealth-enhanced post-authorisation safety study may complete the fundamental quest of RWE for individually improved treatment decisions and balanced therapeutic risk assessment. MSDS3D is carefully designed to contribute to every single objective in this process.
The research and practice of spacecraft software engineering
NASA Astrophysics Data System (ADS)
Chen, Chengxin; Wang, Jinghua; Xu, Xiaoguang
2017-06-01
In order to ensure the safety and reliability of spacecraft software products, it is necessary to execute engineering management. Firstly, the paper introduces the problems of unsystematic planning, uncertain classified management and uncontinuous improved mechanism in domestic and foreign spacecraft software engineering management. Then, it proposes a solution for software engineering management based on system-integrated ideology in the perspective of spacecraft system. Finally, a application result of spacecraft is given as an example. The research can provides a reference for executing spacecraft software engineering management and improving software product quality.