Sample records for high quality test

  1. Assessment and Quality Social Studies

    ERIC Educational Resources Information Center

    Savage, Tom V.

    2003-01-01

    Those anonymous individuals who develop high-stakes tests by which educational quality is measured exercise great influence in defining educational quality. In this article, the author examines the impact of high-stakes testing on the welfare of the children and the quality of social studies instruction. He presents the benefits and drawbacks of…

  2. An Overview of Controls and Flying Qualities Technology on the F/A-18 High Alpha Research Vehicle

    NASA Technical Reports Server (NTRS)

    Pahle, Joseph W.; Wichman, Keith D.; Foster, John V.; Bundick, W. Thomas

    1996-01-01

    The NASA F/A-18 High Alpha Research Vehicle (HARV) has been the flight test bed of a focused technology effort to significantly increase maneuvering capability at high angles of attack. Development and flight test of control law design methodologies, handling qualities metrics, performance guidelines, and flight evaluation maneuvers are described. The HARV has been modified to include two research control effectors, thrust vectoring, and actuated forebody strakes in order to provide increased control power at high angles of attack. A research flight control system has been used to provide a flexible, easily modified capability for high-angle-of-attack research controls. Different control law design techniques have been implemented and flight-tested, including eigenstructure assignment, variable gain output feedback, pseudo controls, and model-following. Extensive piloted simulation has been used to develop nonlinear performance guide-lines and handling qualities criteria for high angles of attack. This paper reviews the development and evaluation of technologies useful for high-angle-of-attack control. Design, development, and flight test of the research flight control system, control laws, flying qualities specifications, and flight test maneuvers are described. Flight test results are used to illustrate some of the lessons learned during flight test and handling qualities evaluations.

  3. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    PubMed

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  4. Enhancing the spatial coverage of a regional high-quality hydraulic conductivity dataset with estimates made from domestic water-well specific-capacity tests

    NASA Astrophysics Data System (ADS)

    Priebe, Elizabeth H.; Neville, C. J.; Rudolph, D. L.

    2018-03-01

    The spatial coverage of hydraulic conductivity ( K) values for large-scale groundwater investigations is often poor because of the high costs associated with hydraulic testing and the large areas under investigation. Domestic water wells are ubiquitous and their well logs represent an untapped resource of information that includes mandatory specific-capacity tests, from which K can be estimated. These specific-capacity tests are routinely conducted at such low pumping rates that well losses are normally insignificant. In this study, a simple and practical approach to augmenting high-quality K values with reconnaissance-level K values from water-well specific-capacity tests is assessed. The integration of lesser quality K values from specific-capacity tests with a high-quality K data set is assessed through comparisons at two different scales: study-area-wide (a 600-km2 area in Ontario, Canada) and in a single geological formation within a portion of the broader study area (200 km2). Results of the comparisons demonstrate that reconnaissance-level K estimates from specific-capacity tests approximate the ranges and distributions of the high-quality K values. Sufficient detail about the physical basis and assumptions that are invoked in the development of the approach are presented here so that it can be applied with confidence by practitioners seeking to enhance their spatial coverage of K values with specific-capacity tests.

  5. Quality assurance and quality improvement in U.S. clinical molecular genetic laboratories.

    PubMed

    Chen, Bin; Richards, C Sue; Wilson, Jean Amos; Lyon, Elaine

    2011-04-01

    A robust quality-assurance program is essential for laboratories that perform molecular genetic testing to maintain high-quality testing and be able to address challenges associated with performance or delivery of testing services as the use of molecular genetic tests continues to expand in clinical and public health practice. This unit discusses quality-assurance and quality-improvement considerations that are critical for molecular genetic testing performed for heritable diseases and conditions. Specific discussion is provided on applying regulatory standards and best practices in establishing/verifying test performance, ensuring quality of the total testing process, monitoring and maintaining personnel competency, and continuing quality improvement. The unit provides a practical reference for laboratory professionals to use in recognizing and addressing essential quality-assurance issues in human molecular genetic testing. It should also provide useful information for genetics researchers, trainees, and fellows in human genetics training programs, as well as others who are interested in quality assurance and quality improvement for molecular genetic testing. 2011 by John Wiley & Sons, Inc.

  6. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    PubMed

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  7. Depth-dependent groundwater quality sampling at City of Tallahassee test well 32, Leon County, Florida, 2013

    USGS Publications Warehouse

    McBride, W. Scott; Wacker, Michael A.

    2015-01-01

    A test well was drilled by the City of Tallahassee to assess the suitability of the site for the installation of a new well for public water supply. The test well is in Leon County in north-central Florida. The U.S. Geological Survey delineated high-permeability zones in the Upper Floridan aquifer, using borehole-geophysical data collected from the open interval of the test well. A composite water sample was collected from the open interval during high-flow conditions, and three discrete water samples were collected from specified depth intervals within the test well during low-flow conditions. Water-quality, source tracer, and age-dating results indicate that the open interval of the test well produces water of consistently high quality throughout its length. The cavernous nature of the open interval makes it likely that the highly permeable zones are interconnected in the aquifer by secondary porosity features.

  8. Microstructural and Material Quality Effects on Rolling Contact Fatigue of Highly Elastic Intermetallic Ball Bearings

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Howard, S. Adam; Thomas, Fransua; Stanford, Malcolm K.

    2016-01-01

    Rolling element bearings made from highly-elastic intermetallic materials (HIM)s, such as 60NiTi, are under development for applications that require superior corrosion and shock resistance. Compared to steel, intermetallics have been shown to have much lower rolling contact fatigue (RCF) stress capability in simplified 3-ball on rod (ASTM STP 771) fatigue tests. In the 3-ball tests, poor material quality and microstructural flaws negatively affect fatigue life but such relationships have not been established for full-scale 60NiTi bearings. In this paper, 3-ball-on-rod fatigue behavior of two quality grades of 60NiTi are compared to the fatigue life of full-scale 50mm bore ball bearings made from the same materials. 60NiTi RCF rods with material or microstructural flaws suffered from infant mortality failures at all tested stress levels while high quality 60NiTi rods exhibited no failures at lower stress levels. Similarly, tests of full-scale bearings made from flawed materials exhibited early surface fatigue and through crack type failures while bearings made from high quality material did not fail even in long-term tests. Though the full-scale bearing test data is yet preliminary, the results suggest that the simplified RCF test is a good qualitative predictor of bearing performance. These results provide guidance for materials development and to establish minimum quality levels required for successful bearing operation and life.

  9. Microstructural and Material Quality Effects on Rolling Contact Fatigue of Highly Elastic Intermetallic NiTi Ball Bearings

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher; Howard, S. Adam; Thomas, Fransua; Stanford, Malcolm K.

    2017-01-01

    Rolling element bearings made from highly-elastic intermetallic materials (HIM)s, such as 60NiTi, are under development for applications that require superior corrosion and shock resistance. Compared to steel, intermetallics have been shown to have much lower rolling contact fatigue (RCF) stress capability in simplified 3-ball on rod (ASTM STP 771) fatigue tests. In the 3-ball tests, poor material quality and microstructural flaws negatively affect fatigue life but such relationships have not been established for full-scale 60NiTi bearings. In this paper, 3-ball-on-rod fatigue behavior of two quality grades of 60NiTi are compared to the fatigue life of full-scale 50mm bore ball bearings made from the same materials. 60NiTi RCF rods with material or microstructural flaws suffered from infant mortality failures at all tested stress levels while high quality 60NiTi rods exhibited no failures at lower stress levels. Similarly, tests of full-scale bearings made from flawed materials exhibited early surface fatigue and through crack type failures while bearings made from high quality material did not fail even in long-term tests. Though the full-scale bearing test data is yet preliminary, the results suggest that the simplified RCF test is a good qualitative predictor of bearing performance. These results provide guidance for materials development and to establish minimum quality levels required for successful bearing operation and life.

  10. Evaluation of the visual performance of image processing pipes: information value of subjective image attributes

    NASA Astrophysics Data System (ADS)

    Nyman, G.; Häkkinen, J.; Koivisto, E.-M.; Leisti, T.; Lindroos, P.; Orenius, O.; Virtanen, T.; Vuori, T.

    2010-01-01

    Subjective image quality data for 9 image processing pipes and 8 image contents (taken with mobile phone camera, 72 natural scene test images altogether) from 14 test subjects were collected. A triplet comparison setup and a hybrid qualitative/quantitative methodology were applied. MOS data and spontaneous, subjective image quality attributes to each test image were recorded. The use of positive and negative image quality attributes by the experimental subjects suggested a significant difference between the subjective spaces of low and high image quality. The robustness of the attribute data was shown by correlating DMOS data of the test images against their corresponding, average subjective attribute vector length data. The findings demonstrate the information value of spontaneous, subjective image quality attributes in evaluating image quality at variable quality levels. We discuss the implications of these findings for the development of sensitive performance measures and methods in profiling image processing systems and their components, especially at high image quality levels.

  11. Water Quality: A Field-Based Quality Testing Program for Middle Schools and High Schools.

    ERIC Educational Resources Information Center

    Massachusetts State Water Resources Authority, Boston.

    This manual contains background information, lesson ideas, procedures, data collection and reporting forms, suggestions for interpreting results, and extension activities to complement a water quality field testing program. Information on testing water temperature, water pH, dissolved oxygen content, biochemical oxygen demand, nitrates, total…

  12. Which Combination of High Quality Infant-Toddler and Preschool Care Best Promotes School Readiness?

    ERIC Educational Resources Information Center

    Li, Weilin; Farkas, George; Duncan, Greg J.; Burchinal, Margaret R.; Vandell, Deborah L.; Ruzek, Erik A.; Dang, Tran T.

    2011-01-01

    This paper aims to test the following hypotheses: Hypothesis 1 (H1): Everything else the same, high quality infant-toddler care will increase children's cognitive scores immediately (i.e. at 24 months of age). However, without subsequent high quality preschool, children with high quality infant-toddler care will not have higher cognitive and…

  13. Naturalness and interestingness of test images for visual quality evaluation

    NASA Astrophysics Data System (ADS)

    Halonen, Raisa; Westman, Stina; Oittinen, Pirkko

    2011-01-01

    Balanced and representative test images are needed to study perceived visual quality in various application domains. This study investigates naturalness and interestingness as image quality attributes in the context of test images. Taking a top-down approach we aim to find the dimensions which constitute naturalness and interestingness in test images and the relationship between these high-level quality attributes. We compare existing collections of test images (e.g. Sony sRGB images, ISO 12640 images, Kodak images, Nokia images and test images developed within our group) in an experiment combining quality sorting and structured interviews. Based on the data gathered we analyze the viewer-supplied criteria for naturalness and interestingness across image types, quality levels and judges. This study advances our understanding of subjective image quality criteria and enables the validation of current test images, furthering their development.

  14. Study of Image Quality From CT Scanner Multi-Detector by using Americans College of Radiology (ACR) Phantom

    NASA Astrophysics Data System (ADS)

    Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang

    2018-03-01

    In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.

  15. The effect of image quality, repeated study, and assessment method on anatomy learning.

    PubMed

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A; Wainman, Bruce C

    2017-06-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality images of the human hand and human eye. On day 0, participants learned about each anatomical specimen from paper booklets using either low-quality or high-quality images, and then completed a comprehension test using either 2D images or three-dimensional (3D) cadaveric specimens. On day 1, participants relearned each booklet, and on day 2 participants completed a final comprehension test using either 2D images or 3D cadaveric specimens. The effect of image quality on learning varied according to anatomical content, with high-quality images having a greater effect on improving learning of hand anatomy than eye anatomy (high-quality vs. low-quality for hand anatomy P = 0.018; high-quality vs. low-quality for eye anatomy P = 0.247). Also, the benefit of high-quality images on hand anatomy learning was restricted to performance on short-answer (SA) questions immediately after learning (high-quality vs. low-quality on SA questions P = 0.018), but did not apply to performance on multiple-choice (MC) questions (high-quality vs. low-quality on MC questions P = 0.109) or after participants had an additional learning opportunity (24 hours later) with anatomy content (high vs. low on SA questions P = 0.643). This study underscores the limited impact of image quality on anatomy learning, and questions whether investment in enhancing image quality of learning aids significantly promotes knowledge development. Anat Sci Educ 10: 249-261. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  16. Access to High Quality Teachers for All Students. Information Brief

    ERIC Educational Resources Information Center

    Mid-Atlantic Equity Center, 2009

    2009-01-01

    One of the most important factors in a high quality education is the knowledge, experience, and capability of the classroom teacher. There is strong evidence that having a high-quality teacher affects learning and is an important factor in explaining student test score gains (Clotfelter, Ladd, & Vigdor, 2007; Darling-Hammond, 2000;…

  17. A Secure Test Technique for Pipelined Advanced Encryption Standard

    NASA Astrophysics Data System (ADS)

    Shi, Youhua; Togawa, Nozomu; Yanagisawa, Masao; Ohtsuki, Tatsuo

    In this paper, we presented a Design-for-Secure-Test (DFST) technique for pipelined AES to guarantee both the security and the test quality during testing. Unlike previous works, the proposed method can keep all the secrets inside and provide high test quality and fault diagnosis ability as well. Furthermore, the proposed DFST technique can significantly reduce test application time, test data volume, and test generation effort as additional benefits.

  18. High-Quality College and Career Ready Assessments. re:VISION

    ERIC Educational Resources Information Center

    Martin, Michael

    2015-01-01

    Assessments matter in education. Testing is nothing new; tests have been around as long as school itself. However, over the last 15 years, state assessments have grown to be an increasingly central, and often controversial, part of schooling. As states raise their standards, it is more important than ever to ask: What is a high-quality assessment?…

  19. Quality-control issues on high-resolution diagnostic monitors.

    PubMed

    Parr, L F; Anderson, A L; Glennon, B K; Fetherston, P

    2001-06-01

    Previous literature indicates a need for more data collection in the area of quality control of high-resolution diagnostic monitors. Throughout acceptance testing, which began in June 2000, stability of monitor calibration was analyzed. Although image quality on all monitors was found to be acceptable upon initial acceptance testing using VeriLUM software by Image Smiths, Inc (Germantown, MD), it was determined to be unacceptable during the clinical phase of acceptance testing. High-resolution monitors were evaluated for quality assurance on a weekly basis from installation through acceptance testing and beyond. During clinical utilization determination (CUD), monitor calibration was identified as a problem and the manufacturer returned and recalibrated all workstations. From that time through final acceptance testing, high-resolution monitor calibration and monitor failure rate remained a problem. The monitor vendor then returned to the site to address these areas. Monitor defocus was still noticeable and calibration checks were increased to three times per week. White and black level drift on medium-resolution monitors had been attributed to raster size settings. Measurements of white and black level at several different size settings were taken to determine the effect of size on white and black level settings. Black level remained steady with size change. White level appeared to increase by 2.0 cd/m2 for every 0.1 inches decrease in horizontal raster size. This was determined not to be the cause of the observed brightness drift. Frequency of calibration/testing is an issue in a clinical environment. The increased frequency required at our site cannot be sustained. The medical physics division cannot provide dedicated personnel to conduct the quality-assurance testing on all monitors at this interval due to other physics commitments throughout the hospital. Monitor access is also an issue due to radiologists' need to read images. Some workstations are in use 7 AM to 11 PM daily. An appropriate monitor calibration frequency must be established during acceptance testing to ensure unacceptable drift is not masked by excessive calibration frequency. Standards for acceptable black level and white level drift also need to be determined. The monitor vendor and hospital staff agree that currently, very small printed text is an acceptable method of determining monitor blur, however, a better method of determining monitor blur is being pursued. Although monitors may show acceptable quality during initial acceptance testing, they need to show sustained quality during the clinical acceptance-testing phase. Defocus, black level, and white level are image quality concerns, which need to be evaluated during the clinical phase of acceptance testing. Image quality deficiencies can have a negative impact on patient care and raise serious medical-legal concerns. The attention to quality control required of the hospital staff needs to be realistic and not have a significant impact on radiology workflow.

  20. Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane

    NASA Technical Reports Server (NTRS)

    Gera, Joseph; Bosworth, John T.

    1987-01-01

    Novel flight test and analysis techniques in the flight dynamics and handling qualities area are described. These techniques were utilized at NASA Ames-Dryden during the initial flight envelope clearance of the X-29A aircraft. It is shown that the open-loop frequency response of an aircraft with highly relaxed static stability can be successfully computed on the ground from telemetry data. Postflight closed-loop frequency response data were obtained from pilot-generated frequency sweeps and it is found that the current handling quality requirements for high-maneuverability aircraft are generally applicable to the X-29A.

  1. Principles for high-quality, high-value testing.

    PubMed

    Power, Michael; Fell, Greg; Wright, Michael

    2013-02-01

    A survey of doctors working in two large NHS hospitals identified over 120 laboratory tests, imaging investigations and investigational procedures that they considered not to be overused. A common suggestion in this survey was that more training was required. And, this prompted the development of a list of core principles for high-quality, high-value testing. The list can be used as a framework for training and as a reference source. The core principles are: (1) Base testing practices on the best available evidence. (2) Apply the evidence on test performance with careful judgement. (3) Test efficiently. (4) Consider the value (and affordability) of a test before requesting it. (5) Be aware of the downsides and drivers of overdiagnosis. (6) Confront uncertainties. (7) Be patient-centred in your approach. (8) Consider ethical issues. (9) Be aware of normal cognitive limitations and biases when testing. (10) Follow the 'knowledge journey' when teaching and learning these core principles.

  2. Physical examination tests for the diagnosis of femoroacetabular impingement. A systematic review.

    PubMed

    Pacheco-Carrillo, Aitana; Medina-Porqueres, Ivan

    2016-09-01

    Numerous clinical tests have been proposed to diagnose FAI, but little is known about their diagnostic accuracy. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of FAI. A search of the PubMed, SPORTDiscus and CINAHL databases was performed. Studies were considered eligible if they compared the results of physical examination tests to those of a reference standard. Methodological quality and internal validity assessment was performed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. The systematic search strategy revealed 298 potential articles, five of which articles met the inclusion criteria. After assessment using the QUADAS score, four of the five articles were of high quality. Clinical tests included were Impingement sign, IROP test (Internal Rotation Over Pressure), FABER test (Flexion-Abduction-External Rotation), Stinchfield/RSRL (Resisted Straight Leg Raise) test, Scour test, Maximal squat test, and the Anterior Impingement test. IROP test, impingement sign, and FABER test showed the most sensitive values to identify FAI. The diagnostic accuracy of physical examination tests to assess FAI is limited due to its heterogenecity. There is a strong need for sound research of high methodological quality in this area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Post-examination interpretation of objective test data: monitoring and improving the quality of high-stakes examinations--a commentary on two AMEE Guides.

    PubMed

    Tavakol, Mohsen; Dennick, Reg

    2012-01-01

    As great emphasis is rightly placed upon the importance of assessment to judge the quality of our future healthcare professionals, it is appropriate not only to choose the most appropriate assessment method, but to continually monitor the quality of the tests themselves, in a hope that we may continually improve the process. This article stresses the importance of quality control mechanisms in the exam cycle and briefly outlines some of the key psychometric concepts including reliability measures, factor analysis, generalisability theory and item response theory. The importance of such analyses for the standard setting procedures is emphasised. This article also accompanies two new AMEE Guides in Medical Education (Tavakol M, Dennick R. Post-examination Analysis of Objective Tests: AMEE Guide No. 54 and Tavakol M, Dennick R. 2012. Post examination analysis of objective test data: Monitoring and improving the quality of high stakes examinations: AMEE Guide No. 66) which provide the reader with practical examples of analysis and interpretation, in order to help develop valid and reliable tests.

  4. Applications of flight control system methods to an advanced combat rotorcraft

    NASA Technical Reports Server (NTRS)

    Tischler, Mark B.; Fletcher, Jay W.; Morris, Patrick M.; Tucker, George T.

    1989-01-01

    Advanced flight control system design, analysis, and testing methodologies developed at the Ames Research Center are applied in an analytical and flight test evaluation of the Advanced Digital Optical Control System (ADOCS) demonstrator. The primary objectives are to describe the knowledge gained about the implications of digital flight control system design for rotorcraft, and to illustrate the analysis of the resulting handling-qualities in the context of the proposed new handling-qualities specification for rotorcraft. Topics covered in-depth are digital flight control design and analysis methods, flight testing techniques, ADOCS handling-qualities evaluation results, and correlation of flight test results with analytical models and the proposed handling-qualities specification. The evaluation of the ADOCS demonstrator indicates desirable response characteristics based on equivalent damping and frequency, but undersirably large effective time-delays (exceeding 240 m sec in all axes). Piloted handling-qualities are found to be desirable or adequate for all low, medium, and high pilot gain tasks; but handling-qualities are inadequate for ultra-high gain tasks such as slope and running landings.

  5. Predicting rheological behavior and baking quality of wheat flour using a GlutoPeak test.

    PubMed

    Rakita, Slađana; Dokić, Ljubica; Dapčević Hadnađev, Tamara; Hadnađev, Miroslav; Torbica, Aleksandra

    2018-06-01

    The purpose of this research was to gain an insight into the ability of the GlutoPeak instrument to predict flour functionality for bread making, as well as to determine which of the GlutoPeak parameters show the best potential in predicting dough rheological behavior and baking performance. Obtained results showed that GlutoPeak parameters correlated better with the indices of extensional rheological tests which consider constant dough hydration than with those which were performed at constant dough consistency. The GlutoPeak test showed that it is suitable for discriminating wheat varieties of good quality from those of poor quality, while the most discriminating index was maximum torque (MT). Moreover, MT value of 50 BU and aggregation energy value of 1,300 GPU were set as limits of wheat flour quality. The backward stepwise regression analysis revealed that a high-level prediction of indices which are highly affected by protein content (gluten content, flour water absorption, and dough tenacity) was achieved by using the GlutoPeak indices. Concerning bread quality, a moderate prediction of specific loaf volume and an intense level prediction of breadcrumb textural properties were accomplished by using the GlutoPeak parameters. The presented results indicated that the application of this quick test in wheat transformation chain for the assessment of baking quality would be useful. Baking test is considered as the most reliable method for assessing wheat-baking quality. However, baking test requires trained stuff, time, and large sample amount. These disadvantages have led to a growing demand to develop new rapid tests which would enable prediction of baked product quality with a limited flour size. Therefore, we tested the possibility of using a GlutoPeak tester to predict loaf volume and breadcrumb textural properties. Discrimination of wheat varieties according to quality with a restricted flour amount was also examined. Furthermore, we proposed the limit values of GlutoPeak parameters which would be highly beneficial for millers and bakers when determine suitability of flour for end-use. © 2017 Wiley Periodicals, Inc.

  6. The Method of Manufacturing Nonmetallic Test-Blocks on Different Sensitivity Classes

    NASA Astrophysics Data System (ADS)

    Kalinichenko, N. P.; Kalinichenko, A. N.; Lobanova, I. S.; Zaitseva, A. A.; Loboda, E. L.

    2016-01-01

    Nowadays in our modern world there is a vital question of quality control of details made from nonmetallic materials due to their wide spreading. Nondestructive penetrant testing is effective, and in some cases it is the only possible method of accidents prevention at high- risk sites. A brief review of check sample necessary for quality evaluation of penetrant materials is considered. There was offered a way of making agents for quality of penetrant materials testing according to different liquid penetrant testing sensibility classes.

  7. Best Practices: Power Quality and Integrated Testing at JSC

    NASA Technical Reports Server (NTRS)

    Davis, Lydia

    2018-01-01

    This presentation discusses Best Practices for Power Quality and Integrated Testing at JSC in regards to electrical systems. These high-level charts include mostly generic information; however, a specific issue is discussed involving flight hardware that could have been discovered prior to flight with an integrated test.

  8. Software quality assurance | News

    Science.gov Websites

    Measure was removed: "Sufficient level of detail in the requirements to develop test cases." ; This control measure was removed since the sufficient level of detail needed to develop test cases is recorded for all test cases. (Note: This is mandatory for applications graded with a High Quality Assurance

  9. Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine: Part 4: Tissue Tools for Quality Assurance in Immunohistochemistry.

    PubMed

    Cheung, Carol C; D'Arrigo, Corrado; Dietel, Manfred; Francis, Glenn D; Fulton, Regan; Gilks, C Blake; Hall, Jacqueline A; Hornick, Jason L; Ibrahim, Merdol; Marchetti, Antonio; Miller, Keith; van Krieken, J Han; Nielsen, Soren; Swanson, Paul E; Taylor, Clive R; Vyberg, Mogens; Zhou, Xiaoge; Torlakovic, Emina E

    2017-04-01

    The numbers of diagnostic, prognostic, and predictive immunohistochemistry (IHC) tests are increasing; the implementation and validation of new IHC tests, revalidation of existing tests, as well as the on-going need for daily quality assurance monitoring present significant challenges to clinical laboratories. There is a need for proper quality tools, specifically tissue tools that will enable laboratories to successfully carry out these processes. This paper clarifies, through the lens of laboratory tissue tools, how validation, verification, and revalidation of IHC tests can be performed in order to develop and maintain high quality "fit-for-purpose" IHC testing in the era of precision medicine. This is the final part of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."

  10. A Procedure for High Resolution Satellite Imagery Quality Assessment

    PubMed Central

    Crespi, Mattia; De Vendictis, Laura

    2009-01-01

    Data products generated from High Resolution Satellite Imagery (HRSI) are routinely evaluated during the so-called in-orbit test period, in order to verify if their quality fits the desired features and, if necessary, to obtain the image correction parameters to be used at the ground processing center. Nevertheless, it is often useful to have tools to evaluate image quality also at the final user level. Image quality is defined by some parameters, such as the radiometric resolution and its accuracy, represented by the noise level, and the geometric resolution and sharpness, described by the Modulation Transfer Function (MTF). This paper proposes a procedure to evaluate these image quality parameters; the procedure was implemented in a suitable software and tested on high resolution imagery acquired by the QuickBird, WorldView-1 and Cartosat-1 satellites. PMID:22412312

  11. Social Anxiety and Friendship Quality over Time.

    PubMed

    Rodebaugh, Thomas L; Lim, Michelle H; Shumaker, Erik A; Levinson, Cheri A; Thompson, Tess

    2015-01-01

    High social anxiety in adults is associated with self-report of impaired friendship quality, but not necessarily with impairment reported by friends. Further, prospective prediction of social anxiety and friendship quality over time has not been tested among adults. We therefore examined friendship quality and social anxiety prospectively in 126 young adults (67 primary participants and 59 friends, aged 17-22 years); the primary participants were screened to be extreme groups to increase power and relevance to clinical samples (i.e., they were recruited based on having very high or very low social interaction anxiety). The prospective relationships between friendship quality and social anxiety were then tested using an Actor-Partner Interdependence Model. Friendship quality prospectively predicted social anxiety over time within each individual in the friendship, such that higher friendship quality at Time 1 predicted lower social anxiety approximately 6 months later at Time 2. Social anxiety did not predict friendship quality. Although the results support the view that social anxiety and friendship quality have an important causal relationship, the results run counter to the assumption that high social anxiety causes poor friendship quality. Interventions to increase friendship quality merit further consideration.

  12. Field Performance of High-Quality and Standard Northern Red Oak Seedlings in Tennessee

    Treesearch

    David S. Buckley

    2002-01-01

    First-year performance of high-quality (HQ), high-quality cull (HQC) and standard (ST) northern red oak (Quercus rubra) nursery seedlings was compared in a study established in a recent clearcut in mid-March, 2000. Objectives were to test effects of 1) seedling type, 2) planting treatment, and 3) control of competitors on the growth, browsing, and...

  13. The Nutritional Content of Prey Affects the Foraging of a Generalist Arthropod Predator

    PubMed Central

    Schmidt, Jason M.; Sebastian, Peter; Wilder, Shawn M.; Rypstra, Ann L.

    2012-01-01

    While foraging theory predicts that predatory responses should be determined by the energy content and size of prey, it is becoming increasingly clear that carnivores regulate their intake of specific nutrients. We tested the hypothesis that prey nutrient composition and predator nutritional history affects foraging intensity, consumption, and prey selection by the wolf spider, Pardosa milvina. By altering the rearing environment for fruit flies, Drosophila melanogaster, we produced high quality flies containing more nitrogen and protein and less lipid than low quality fruit flies. In one experiment, we quantified the proportion of flies taken and consumption across a range of densities of either high or low quality flies and, in a second experiment, we determined the prey capture and consumption of spiders that had been maintained on contrasting diets prior to testing. In both cases, the proportion of prey captured declined with increasing prey density, which characterizes the Type II functional response that is typical of wolf spiders. Spiders with similar nutritional histories killed similar numbers of each prey type but consumed more of the low quality prey. Spiders provided high quality prey in the weeks prior to testing killed more prey than those on the low quality diet but there was no effect of prior diet on consumption. In the third experiment, spiders were maintained on contrasting diets for three weeks and then allowed to select from a mixture of high and low quality prey. Interestingly, feeding history affected prey preferences: spiders that had been on a low quality diet showed no preference but those on the high quality diet selected high quality flies from the mixture. Our results suggest that, even when prey size and species identity are controlled, the nutritional experience of the predator as well as the specific content of the prey shapes predator-prey interactions. PMID:23145130

  14. Evaluation of flow quality in two large NASA wind tunnels at transonic speeds

    NASA Technical Reports Server (NTRS)

    Harvey, W. D.; Stainback, P. C.; Owen, F. K.

    1980-01-01

    Wind tunnel testing of low drag airfoils and basic transition studies at transonic speeds are designed to provide high quality aerodynamic data at high Reynolds numbers. This requires that the flow quality in facilities used for such research be excellent. To obtain a better understanding of the characteristics of facility disturbances and identification of their sources for possible facility modification, detailed flow quality measurements were made in two prospective NASA wind tunnels. Experimental results are presented of an extensive and systematic flow quality study of the settling chamber, test section, and diffuser in the Langley 8 foot transonic pressure tunnel and the Ames 12 foot pressure wind tunnel. Results indicate that the free stream velocity and pressure fluctuation levels in both facilities are low at subsonic speeds and are so high as to make it difficult to conduct meaningful boundary layer control and transition studies at transonic speeds.

  15. Predicting Software Assurance Using Quality and Reliability Measures

    DTIC Science & Technology

    2014-12-01

    errors are not found in unit testing . The rework effort to correct requirement and design problems in later phases can be as high as 300 to 1,000...Literature 31 Appendix B: Quality Cannot Be Tested In 35 Bibliography 38 CMU/SEI-2014-TN-026 | ii CMU/SEI-2014-TN-026 | iii List of Figures...Removal Densities During Development 10 Figure 8: Quality and Security-Focused Workflow 14 Figure 9: Testing Reliability Results for the Largest Project

  16. Do the Guideline Violations Influence Test Difficulty of High-Stake Test?: An Investigation on University Entrance Examination in Turkey

    ERIC Educational Resources Information Center

    Atalmis, Erkan Hasan

    2016-01-01

    Multiple-choice (MC) items are commonly used in high-stake tests. Thus, each item of such tests should be meticulously constructed to increase the accuracy of decisions based on test results. Haladyna and his colleagues (2002) addressed the valid item-writing guidelines to construct high quality MC items in order to increase test reliability and…

  17. Critically Loaded Hole Technology Pilot Collaborative Test Programme.

    DTIC Science & Technology

    1980-11-01

    270 rpm Spindle Speed - 1450 rpm Feed Rate - Manual Feed Rate - Manual Cutting Fluid - Dry Cutting Fluid - Dry Tool Type - Cordia S-18 Tool Type... Cordia S-18 TABLE XI MANUFACTURING DETAILS FOR HIGH AND LOW QUALITY HOLES SELECTED BY THE UNITED KINGDOM HIGH QUALITY LOW QUALITY Pilot Hole: - 1/8 inch

  18. Capacity building and predictors of success for HIV-1 drug resistance testing in the Asia-Pacific region and Africa

    PubMed Central

    Land, Sally; Zhou, Julian; Cunningham, Philip; Sohn, Annette H; Singtoroj, Thida; Katzenstein, David; Mann, Marita; Sayer, David; Kantor, Rami

    2013-01-01

    Background The TREAT Asia Quality Assessment Scheme (TAQAS) was developed as a quality assessment programme through expert education and training, for laboratories in the Asia-Pacific and Africa that perform HIV drug-resistance (HIVDR) genotyping. We evaluated the programme performance and factors associated with high-quality HIVDR genotyping. Methods Laboratories used their standard protocols to test panels of human immunodeficiency virus (HIV)-positive plasma samples or electropherograms. Protocols were documented and performance was evaluated according to a newly developed scoring system, agreement with panel-specific consensus sequence, and detection of drug-resistance mutations (DRMs) and mixtures of wild-type and resistant virus (mixtures). High-quality performance was defined as detection of ≥95% DRMs. Results Over 4.5 years, 23 participating laboratories in 13 countries tested 45 samples (30 HIV-1 subtype B; 15 non-B subtypes) in nine panels. Median detection of DRMs was 88–98% in plasma panels and 90–97% in electropherogram panels. Laboratories were supported to amend and improve their test outcomes as appropriate. Three laboratories that detected <80% DRMs in early panels demonstrated subsequent improvement. Sample complexity factors – number of DRMs (p<0.001) and number of DRMs as mixtures (p<0.001); and laboratory performance factors – detection of mixtures (p<0.001) and agreement with consensus sequence (p<0.001), were associated with high performance; sample format (plasma or electropherogram), subtype and genotyping protocol were not. Conclusion High-quality HIVDR genotyping was achieved in the TAQAS collaborative laboratory network. Sample complexity and detection of mixtures were associated with performance quality. Laboratories conducting HIVDR genotyping are encouraged to participate in quality assessment programmes. PMID:23845227

  19. Evaluation of High-Angle-of-Attack Handling Qualities for the X-31A Using Standard Evaluation Maneuvers

    NASA Technical Reports Server (NTRS)

    Stoliker, Patrick C.; Bosworth, John T.

    1996-01-01

    The X-31A aircraft gross-acquisition and fine-tracking handling qualities have been evaluated using standard evaluation maneuvers developed by Wright Laboratory, Wright-Patterson Air Force Base. The emphasis of the testing is in the angle-of-attack range between 30 deg and 70 deg. Longitudinal gross-acquisition handling qualities results show borderline Level 1/Level 2 performance. Lateral gross-acquisition testing results in Level 1/Level 2 ratings below 45 deg angle of attack, degrading into Level 3 as angle of attack increases. The fine-tracking performance in both longitudinal and lateral axes also receives Level 1 ratings near 30 deg angle of attack, with the ratings tending towards Level 3 at angles of attack greater than 50 deg. These ratings do not match the expectations from the extensive close-in combat testing where the X-31A aircraft demonstrated fair to good handling qualities maneuvering for high angles of attack. This paper presents the results of the high-angle-of-attack handling qualities flight testing of the X-31A aircraft. Discussion of the preparation for the maneuvers, the pilot ratings, and selected pilot comments are included. Evaluation of the results is made in conjunction with existing Neal-Smith, bandwidth, Smith-Geddes, and military specifications.

  20. Evaluation of High-Angle-of-Attack Handling Qualities for the X-31A Using Standard Evaluation Maneuvers

    NASA Technical Reports Server (NTRS)

    Stoliker, Patrick C.; Bosworth, John T.

    1997-01-01

    The X-31A aircraft gross-acquisition and fine-tracking handling qualities have been evaluated using standard evaluation maneuvers developed by Wright Laboratory, Wright Patterson Air Force Base. The emphasis of the testing is in the angle-of-attack range between 30 deg. and 70 deg. Longitudinal gross-acquisition handling qualities results show borderline Level l/Level 2 performance. Lateral gross-acquisition testing results in Level l/Level 2 ratings below 45 deg. angle of attack, degrading into Level 3 as angle of attack increases. The fine tracking performance in both longitudinal and lateral axes also receives Level 1 ratings near 30 deg. angle of attack, with the ratings tending towards Level 3 at angles of attack greater than 50 deg. These ratings do not match the expectations from the extensive close-in combat testing where the X-31A aircraft demonstrated fair to good handling qualities maneuvering for high angles of attack. This paper presents the results of the high-angle-of-attack handling qualities flight testing of the X-31A aircraft. Discussion of the preparation for the maneuvers, the pilot ratings, and selected pilot comments are included. Evaluation of the results is made in conjunction with existing Neal Smith, bandwidth, Smith-Geddes, and military specifications.

  1. Development and evaluation of oral Cancer quality-of-life questionnaire (QOL-OC).

    PubMed

    Nie, Min; Liu, Chang; Pan, Yi-Chen; Jiang, Chen-Xi; Li, Bao-Ru; Yu, Xi-Jie; Wu, Xin-Yu; Zheng, Shu-Ning

    2018-05-03

    In this study scales and items for the Oral Cancer Quality-of-life Questionnaire (QOL-OC) were designed and the instrument was evaluated. The QOL-OC was developed and modified using the international definition of quality of life (QOL) promulgated by the European Organization for Research and Treatment of Cancer (EORTC) and analysis of the precedent measuring instruments. The contents of each item were determined in the context of the specific characteristics of oral cancer. Two hundred thirteen oral cancer patients were asked to complete both the EORTC core quality of life questionnaire (EORTC QLC-C30) and the QOL-OC. Data collected was used to conduct factor analysis, test-retest reliability, internal consistency, and construct validity. Questionnaire compliance was relatively high. Fourteen of the 213 subjects accepted the same tests after 24 to 48 h demonstrating a high test-retest reliability for all five scales. Overall internal consistency surpasses 0.8. The outcome of the factor analysis coincides substantially with our theoretical conception. Each item shows a higher correlation coefficient within its own scale than the others which indicates high construct validity. QOL-OC demonstrates fairly good statistical reliability, validity, and feasibility. However, further tests and modification are needed to ensure its applicability to the quality-of-life assessment of Chinese oral cancer patients.

  2. SOAC - State-of-the-Art Car Engineering Tests at Department of Transportation High Speed Ground Test Center : Volume 3. Ride Quality Tests.

    DOT National Transportation Integrated Search

    1975-01-01

    The six-volume report presents the technical methodology, data samples, and results of tests conducted on the SOAC on the Rail Transit Test Track at the High Speed Ground Test Center in Pueblo, Colorado during the period April to July 1973. The Test ...

  3. Flight test experience with high-alpha control system techniques on the F-14 airplane

    NASA Technical Reports Server (NTRS)

    Gera, J.; Wilson, R. J.; Enevoldson, E. K.; Nguyen, L. T.

    1981-01-01

    Improved handling qualities of fighter aircraft at high angles of attack can be provided by various stability and control augmentation techniques. NASA and the U.S. Navy are conducting a joint flight demonstration of these techniques on an F-14 airplane. This paper reports on the flight test experience with a newly designed lateral-directional control system which suppresses such high angle of attack handling qualities problems as roll reversal, wing rock, and directional divergence while simultaneously improving departure/spin resistance. The technique of integrating a piloted simulation into the flight program was used extensively in this program. This technique had not been applied previously to high angle of attack testing and required the development of a valid model to simulate the test airplane at extremely high angles of attack.

  4. An assessment of quality of home-based HIV counseling and testing performed by lay counselors in a rural sub-district of KwaZulu-Natal, South Africa.

    PubMed

    Magasana, Vuyolwethu; Zembe, Wanga; Tabana, Hanani; Naik, Reshma; Jackson, Debra; Swanevelder, Sonja; Doherty, Tanya

    2016-12-01

    HIV counseling and testing (HCT) has been prioritized as one of the prevention strategies for HIV/AIDS, and promoted as an essential tool in scaling up and improving access to treatment, care and support especially in community settings. Home-based HCT (HBHCT) is a model that has consistently been found to be highly acceptable and has improved HCT coverage and uptake in low- and middle-income countries since 2002. It involves trained lay counselors going door-to-door offering pre-test counseling and providing HCT services to consenting eligible household members. Currently, there are few studies reporting on the quality of HBHCT services offered by lay counselors especially in Sub-Saharan Africa, including South Africa. This is a quantitative descriptive sub-study of a community randomized trial (Good Start HBHCT trial) which describes the quality of HBHCT provided by lay counselors. Quality of HBHCT was measured as scores comparing observed practice to prescribed protocols using direct observation. Data were collected through periodic observations of HCT sessions and exit interviews with clients. Counselor quality scores for pre-test counseling and post-test counseling sessions were created to determine the level of quality. For the client exit interviews a continuous score was created to assess how satisfied the clients were with the counseling session. A total of 196 (3%) observational assessments and 406 (6%) client exit interviews were completed. Overall, median scores for quality of counseling and testing were high for both HIV-negative and HIV-positive clients. For exit interviews all 406 (100%) clients had overall satisfaction with the counseling and testing services they received, however 11% were concerned about the counselor keeping their discussion confidential. Of all 406 clients, 393 (96.8%) intended to recommend the service to other people. In ensuring good quality HCT services, ongoing quality assessments are important to monitor quality of HCT after training.

  5. United3D: a protein model quality assessment program that uses two consensus based methods.

    PubMed

    Terashi, Genki; Oosawa, Makoto; Nakamura, Yuuki; Kanou, Kazuhiko; Takeda-Shitaka, Mayuko

    2012-01-01

    In protein structure prediction, such as template-based modeling and free modeling (ab initio modeling), the step that assesses the quality of protein models is very important. We have developed a model quality assessment (QA) program United3D that uses an optimized clustering method and a simple Cα atom contact-based potential. United3D automatically estimates the quality scores (Qscore) of predicted protein models that are highly correlated with the actual quality (GDT_TS). The performance of United3D was tested in the ninth Critical Assessment of protein Structure Prediction (CASP9) experiment. In CASP9, United3D showed the lowest average loss of GDT_TS (5.3) among the QA methods participated in CASP9. This result indicates that the performance of United3D to identify the high quality models from the models predicted by CASP9 servers on 116 targets was best among the QA methods that were tested in CASP9. United3D also produced high average Pearson correlation coefficients (0.93) and acceptable Kendall rank correlation coefficients (0.68) between the Qscore and GDT_TS. This performance was competitive with the other top ranked QA methods that were tested in CASP9. These results indicate that United3D is a useful tool for selecting high quality models from many candidate model structures provided by various modeling methods. United3D will improve the accuracy of protein structure prediction.

  6. The Relevance of External Quality Assessment for Molecular Testing for ALK Positive Non-Small Cell Lung Cancer: Results from Two Pilot Rounds Show Room for Optimization

    PubMed Central

    Tembuyser, Lien; Tack, Véronique; Zwaenepoel, Karen; Pauwels, Patrick; Miller, Keith; Bubendorf, Lukas; Kerr, Keith; Schuuring, Ed; Thunnissen, Erik; Dequeker, Elisabeth M. C.

    2014-01-01

    Background and Purpose Molecular profiling should be performed on all advanced non-small cell lung cancer with non-squamous histology to allow treatment selection. Currently, this should include EGFR mutation testing and testing for ALK rearrangements. ROS1 is another emerging target. ALK rearrangement status is a critical biomarker to predict response to tyrosine kinase inhibitors such as crizotinib. To promote high quality testing in non-small cell lung cancer, the European Society of Pathology has introduced an external quality assessment scheme. This article summarizes the results of the first two pilot rounds organized in 2012–2013. Materials and Methods Tissue microarray slides consisting of cell-lines and resection specimens were distributed with the request for routine ALK testing using IHC or FISH. Participation in ALK FISH testing included the interpretation of four digital FISH images. Results Data from 173 different laboratories was obtained. Results demonstrate decreased error rates in the second round for both ALK FISH and ALK IHC, although the error rates were still high and the need for external quality assessment in laboratories performing ALK testing is evident. Error rates obtained by FISH were lower than by IHC. The lowest error rates were observed for the interpretation of digital FISH images. Conclusion There was a large variety in FISH enumeration practices. Based on the results from this study, recommendations for the methodology, analysis, interpretation and result reporting were issued. External quality assessment is a crucial element to improve the quality of molecular testing. PMID:25386659

  7. The relevance of external quality assessment for molecular testing for ALK positive non-small cell lung cancer: results from two pilot rounds show room for optimization.

    PubMed

    Tembuyser, Lien; Tack, Véronique; Zwaenepoel, Karen; Pauwels, Patrick; Miller, Keith; Bubendorf, Lukas; Kerr, Keith; Schuuring, Ed; Thunnissen, Erik; Dequeker, Elisabeth M C

    2014-01-01

    Molecular profiling should be performed on all advanced non-small cell lung cancer with non-squamous histology to allow treatment selection. Currently, this should include EGFR mutation testing and testing for ALK rearrangements. ROS1 is another emerging target. ALK rearrangement status is a critical biomarker to predict response to tyrosine kinase inhibitors such as crizotinib. To promote high quality testing in non-small cell lung cancer, the European Society of Pathology has introduced an external quality assessment scheme. This article summarizes the results of the first two pilot rounds organized in 2012-2013. Tissue microarray slides consisting of cell-lines and resection specimens were distributed with the request for routine ALK testing using IHC or FISH. Participation in ALK FISH testing included the interpretation of four digital FISH images. Data from 173 different laboratories was obtained. Results demonstrate decreased error rates in the second round for both ALK FISH and ALK IHC, although the error rates were still high and the need for external quality assessment in laboratories performing ALK testing is evident. Error rates obtained by FISH were lower than by IHC. The lowest error rates were observed for the interpretation of digital FISH images. There was a large variety in FISH enumeration practices. Based on the results from this study, recommendations for the methodology, analysis, interpretation and result reporting were issued. External quality assessment is a crucial element to improve the quality of molecular testing.

  8. High angle of attack flying qualities criteria for longitudinal rate command systems

    NASA Technical Reports Server (NTRS)

    Wilson, David J.; Citurs, Kevin D.; Davidson, John B.

    1994-01-01

    This study was designed to investigate flying qualities requirements of alternate pitch command systems for fighter aircraft at high angle of attack. Flying qualities design guidelines have already been developed for angle of attack command systems at 30, 45, and 60 degrees angle of attack, so this research fills a similar need for rate command systems. Flying qualities tasks that require post-stall maneuvering were tested during piloted simulations in the McDonnell Douglas Aerospace Manned Air Combat Simulation facility. A generic fighter aircraft model was used to test angle of attack rate and pitch rate command systems for longitudinal gross acquisition and tracking tasks at high angle of attack. A wide range of longitudinal dynamic variations were tested at 30, 45, and 60 degrees angle of attack. Pilot comments, Cooper-Harper ratings, and pilot induced oscillation ratings were taken from five pilots from NASA, USN, CAF, and McDonnell Douglas Aerospace. This data was used to form longitudinal design guidelines for rate command systems at high angle of attack. These criteria provide control law design guidance for fighter aircraft at high angle of attack, low speed flight conditions. Additional time history analyses were conducted using the longitudinal gross acquisition data to look at potential agility measures of merit and correlate agility usage to flying qualities boundaries. This paper presents an overview of this research.

  9. Child Care Quality and Cognitive Development: Trajectories Leading to Better Preacademic Skills

    ERIC Educational Resources Information Center

    Cote, Sylvana M.; Mongeau, Chantal; Japel, Christa; Xu, Qian; Seguin, Jean R.; Tremblay, Richard E.

    2013-01-01

    The associations between trajectories of child care quality from ages 2 to 4 years and children's cognitive performance at 4 years ("n" = 250) were tested. Distinct quality trajectories were identified: low and high ascending Teaching and Interactions trajectory; low and high Provision for Learning trajectory. Membership in the high…

  10. School Quality and the Development of Cognitive Skills between Age Four and Six

    PubMed Central

    Borghans, Lex; Golsteyn, Bart H. H.; Zölitz, Ulf

    2015-01-01

    This paper studies the extent to which young children develop their cognitive ability in high and low quality schools. We use a representative panel data set containing cognitive test scores of 4-6 year olds in Dutch schools. School quality is measured by the school’s average achievement test score at age 12. Our results indicate that children in high-quality schools develop their skills substantially faster than those in low-quality schools. The results remain robust to the inclusion of initial ability, parental background, and neighborhood controls. Moreover, using proximity to higher-achieving schools as an instrument for school choice corroborates the results. The robustness of the results points toward a causal interpretation, although it is not possible to erase all doubt about unobserved confounding factors. PMID:26182123

  11. The steady-state flow quality in a model of a non-return wind tunnel

    NASA Technical Reports Server (NTRS)

    Mort, K. W.; Eckert, W. T.; Kelly, M. W.

    1972-01-01

    The structural cost of non-return wind tunnels is significantly less than that of the more conventional closed-circuit wind tunnels. However, because of the effects of external winds, the flow quality of non-return wind tunnels is an area of concern at the low test speeds required for V/STOL testing. The flow quality required at these low speeds is discussed and alternatives to the traditional manner of specifying the flow quality requirements in terms of dynamic pressure and angularity are suggested. The development of a non-return wind tunnel configuration which has good flow quality at low as well as at high test speeds is described.

  12. Implementation of 350-2500 nm diffuse reflectance spectroscopy and High-Performance Thin-Layer Chromatography to rapidly assess manufacturing consistency and quality of cotrimoxazole tablets in Tanzania.

    PubMed

    Kaale, Eliangiringa; Hope, Samuel M; Jenkins, David; Layloff, Thomas

    2016-01-01

    To assess the quality of cotrimoxazole tablets produced by a Tanzanian manufacturer by a newly instituted quality assurance programme. Tablets underwent a diffuse reflectance spectroscopy procedure with periodic quality assessment confirmation by assay and dissolution testing using validated HPTLC techniques (including weight variation and disintegration evaluations). Based on results from the primary test methods, the first group of product was <80% compliant, whereas subsequent groups reached >99% compliance. This approach provides a model for rapidly assuring product quality of future procurements of other products that is more cost-effective than traditional pharmaceutical testing techniques. © 2015 John Wiley & Sons Ltd.

  13. "Know Your Well" A Groundwater Quality Project to Inform Students and Well-Owners

    NASA Astrophysics Data System (ADS)

    Olson, C.; Snow, D.; Samal, A.; Ray, C.; Kreifels, M.

    2017-12-01

    Over 15 million U.S. households rely on private, household wells for drinking water, and these sources are not protected under the Safe Drinking Water Act. Data on private well water quality is slowly being collected and evaluated from a number of different agencies, sources and projects. A new project is designed both for training high school students and to help assess the quality of water from rural domestic wells in Nebraska. This "crowd sourced" program engaging high school agricultural education programs, FFA chapters, and science classes with students sampling and testing water sampling from rural domestic wells from 12 districts across the state. Students and teachers from selected school were trained through multiple school visits, both in the classroom and in the field. Classroom visits were used to introduce topics such as water quality and groundwater, and testing methods for specific analytes. During the field visit, students were exposed to field techniques, the importance of accuracy in data collection, and what factors might influence the water in sampled wells. High school students learn to sample and test water independently. Leadership and initiative is developed through the program, and many experience the enlightenment that comes with citizen science. A customized mobile app was developed for ease of data entry and visualization, and data uploaded to a secure website where information was stored and compared to laboratory tests of the same measurements. General water quality parameters, including pH, electrical conductivity, major anions are tested in the field and laboratory, as well as environmental contaminants such as arsenic, uranium, pesticides, bacteria. Test kits provided to each class were used by the students to measure selected parameters, and then duplicate water samples were analyzed at a university laboratory. Five high schools are involved in the project during its first year. Nitrate, bacteria and pesticides represent major concerns for private well owners across the U.S. and preliminary results indicate that nitrate concentrations can range up to 70 mg/L, while detections of bacteria and traces of pesticide residues are consistent with other studies. This project will help both high school students and private well owner become better-informed about water quality in Nebraska.

  14. Appropriate use of screening and diagnostic tests to foster high-value, cost-conscious care.

    PubMed

    Qaseem, Amir; Alguire, Patrick; Dallas, Paul; Feinberg, Lawrence E; Fitzgerald, Faith T; Horwitch, Carrie; Humphrey, Linda; LeBlond, Richard; Moyer, Darilyn; Wiese, Jeffrey G; Weinberger, Steven

    2012-01-17

    Unsustainable rising health care costs in the United States have made reducing costs while maintaining high-quality health care a national priority. The overuse of some screening and diagnostic tests is an important component of unnecessary health care costs. More judicious use of such tests will improve quality and reflect responsible awareness of costs. Efforts to control expenditures should focus not only on benefits, harms, and costs but on the value of diagnostic tests-meaning an assessment of whether a test provides health benefits that are worth its costs or harms. To begin to identify ways that practicing clinicians can contribute to the delivery of high-value, cost-conscious health care, the American College of Physicians convened a workgroup of physicians to identify, using a consensus-based process, common clinical situations in which screening and diagnostic tests are used in ways that do not reflect high-value care. The intent of this exercise is to promote thoughtful discussions about these tests and other health care interventions to promote high-value, cost-conscious care.

  15. Dietary quality and encephalization in platyrrhine primates.

    PubMed

    Allen, Kari L; Kay, Richard F

    2012-02-22

    The high energetic costs of building and maintaining large brains are thought to constrain encephalization. The 'expensive-tissue hypothesis' (ETH) proposes that primates (especially humans) overcame this constraint through reduction of another metabolically expensive tissue, the gastrointestinal tract. Small guts characterize animals specializing on easily digestible diets. Thus, the hypothesis may be tested via the relationship between brain size and diet quality. Platyrrhine primates present an interesting test case, as they are more variably encephalized than other extant primate clades (excluding Hominoidea). We find a high degree of phylogenetic signal in the data for diet quality, endocranial volume and body size. Controlling for phylogenetic effects, we find no significant correlation between relative diet quality and relative endocranial volume. Thus, diet quality fails to account for differences in platyrrhine encephalization. One taxon, in particular, Brachyteles, violates predictions made by ETH in having a large brain and low-quality diet. Dietary reconstructions of stem platyrrhines further indicate that a relatively high-quality diet was probably in place prior to increases in encephalization. Therefore, it is unlikely that a shift in diet quality was a primary constraint release for encephalization in platyrrhines and, by extrapolation, humans.

  16. [The establishment and application of internal quality control system for real-time quantitative PCR detection of BCR-ABL (P210) transcript levels].

    PubMed

    Zhong, C Q; He, N; Hua, M Q; Wei, X D; Ma, D X; Ji, C Y

    2016-09-14

    Objective: To set internal quality control system of BCR-ABL (P210) transcript levels for real-time quantitative PCR (RQ-PCR). Methods: Using K562 cells and HL-60 cells, we prepared high- and low-level BCR-ABL internal quality control substance. The BCR-ABL (P210) transcript levels of internal quality control substance have been determined for 184 times together with clinical samples from August 2013 to October 2015. The slope rate, intercept and correlation coefficient of standard curve were calculated according to different reagent lots (lots number 20130303, 20131212, 20140411 and 20150327 are called R1、R2、R3 and R4 for short respectively), and the detection results of quality control substance were calculated according to different reagent lots and quality control substance lots (lots number 20130725, 20140611 are called Q1、Q2 for short respectively). Then the results were analyzed by Levey-Jennings quality control chart combined with Westgard multi-rules theory. Results: ①We analyzed the slope rate and intercept of standard curve. Fifty-three times of the R1 reagent detection, 80 times of the R3 reagent detection and 14 times of the R4 reagent detection were all under control. For 37 times detection of R2 reagent, the slope rate was out of control for 6 times. It was lower than x - s for the 2-8 tests and upper the average for the 12-37 tests. The intercept was out of control for 9 times, upper the x + s for the 1-8 tests and lower the average for the 12-37 tests. ② According to the detection results of quality control substance, for Q1 quality control substance, 49 tests by R1 reagent were under control, and 1 out of 23 tests by R2 reagent was out of control. For Q2 quality control substance, 14 tests by R2 reagent detection, 72 tests by R3 reagent detection and 14 tests by R4 reagent were all under control. Conclusion: The preparation of high- and low-level quality control substance using K562 and HL-60 cells was convenient and the detection results were reliable and stable. The application of quality control substance combined with slope rate and intercept in the internal quality control may contribute to quality assurance for quantitative detection of BCR-ABL (P210) transcript levels.

  17. Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane

    NASA Technical Reports Server (NTRS)

    Gera, Joseph; Bosworth, John T.

    1987-01-01

    Initial envelope clearance and subsequent flight testing of a new, fully augmented airplane with an extremely high degree of static instability can place unusual demands on the flight test approach. Previous flight test experience with these kinds of airplanes is very limited or nonexistent. The safe and efficient flight testing may be further complicated by a multiplicity of control effectors that may be present on this class of airplanes. This paper describes some novel flight test and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays.

  18. Challenges in Routine Implementation and Quality Control of Rapid Diagnostic Tests for Malaria–Rufiji District, Tanzania

    PubMed Central

    McMorrow, Meredith L.; Masanja, M. Irene; Abdulla, Salim M. K.; Kahigwa, Elizeus; Kachur, S. Patrick

    2018-01-01

    Rapid diagnostic tests (RDTs) represent an alternative to microscopy for malaria diagnosis and have shown high sensitivity and specificity in a variety of study settings. Current World Health Organization (WHO) guidelines for quality control of RDTs provide detailed instructions on pre-field testing, but offer little guidance for quality assurance once RDTs are deployed in health facilities. From September 2006 to April 2007, we introduced a histidine-rich protein II (HRP2)-based RDT (Paracheck) for suspected malaria cases five years of age and older in nine health facilities in Rufiji District, Tanzania, to assess sensitivity and specificity of RDTs in routine use at rural health facilities. Thick blood smears were collected for all patients tested with RDTs and stained and read by laboratory personnel in each facility. Thick smears were subsequently reviewed by a reference microscopist to determine RDT sensitivity and specificity. In all nine health facilities, there were significant problems with the quality of staining and microscopy. Sensitivity and specificity of RDTs were difficult to assess given the poor quality of routine blood smear staining. Mean operational sensitivity of RDTs based on reference microscopy was 64.8%, but varied greatly by health facility, range 18.8–85.9%. Sensitivity of RDTs increased with increasing parasite density. Specificity remained high at 87.8% despite relatively poor slide quality. Institution of quality control of RDTs based on poor quality blood smear staining may impede reliable measurement of sensitivity and specificity and undermine confidence in the new diagnostic. There is an urgent need for the development of alternative quality control procedures for rapid diagnostic tests that can be performed at the facility level. PMID:18784230

  19. Education Policy-Making and Time

    ERIC Educational Resources Information Center

    Thompson, Greg; Cook, Ian

    2014-01-01

    This paper examines the global policy convergence toward high-stakes testing in schools and the use of test results to "steer at a distance", particularly as it applies to policy-makers' promise to improve teacher quality. Using Deleuze's three syntheses of time in the context of the Australian policy blueprint Quality Education, this…

  20. Quality assurance testing of a high performance steel bridge in Virginia.

    DOT National Transportation Integrated Search

    2005-01-01

    One of the original objectives of this study was to recommend appropriate procedures for welding bridge members of high performance steel HPS70W to assure quality welds. The final objective was to determine whether hydrogen-induced microcracking migh...

  1. [Ophthalmologic reading charts : Part 2: Current logarithmically scaled reading charts].

    PubMed

    Radner, W

    2016-12-01

    To analyze currently available reading charts regarding print size, logarithmic print size progression, and the background of test-item standardization. For the present study, the following logarithmically scaled reading charts were investigated using a measuring microscope (iNexis VMA 2520; Nikon, Tokyo): Eschenbach, Zeiss, OCULUS, MNREAD (Minnesota Near Reading Test), Colenbrander, and RADNER. Calculations were made according to EN-ISO 8596 and the International Research Council recommendations. Modern reading charts and cards exhibit a logarithmic progression of print sizes. The RADNER reading charts comprise four different cards with standardized test items (sentence optotypes), a well-defined stop criterion, accurate letter sizes, and a high print quality. Numbers and Landolt rings are also given in the booklet. The OCULUS cards have currently been reissued according to recent standards and also exhibit a high print quality. In addition to letters, numbers, Landolt rings, and examples taken from a timetable and the telephone book, sheet music is also offered. The Colenbrander cards use short sentences of 44 characters, including spaces, and exhibit inaccuracy at smaller letter sizes, as do the MNREAD cards. The MNREAD cards use sentences of 60 characters, including spaces, and have a high print quality. Modern reading charts show that international standards can be achieved with test items similar to optotypes, by using recent technology and developing new concepts of test-item standardization. Accurate print sizes, high print quality, and a logarithmic progression should become the minimum requirements for reading charts and reading cards in ophthalmology.

  2. Caregiver social support quality when interacting with cancer survivors: advancing the dual-process model of supportive communication.

    PubMed

    Harvey-Knowles, Jacquelyn; Faw, Meara H

    2018-04-01

    Cancer caregivers often experience significant challenges in their motivation and ability to comfort cancer survivors, particularly in a spousal or romantic context. Spousal cancer caregivers have been known to report even greater levels of burden and distress than cancer sufferers, yet still take on the role of acting as an informal caregiver so they can attend to their partner's needs. The current study tested whether a theoretical model of supportive outcomes-the dual-process model of supportive communication-explained variations in cancer caregivers' motivation and ability to create high-quality support messages. The study also tested whether participant engagement with reflective journaling on supportive acts was associated with increased motivation or ability to generate high-quality support messages. Based upon the dual-process model, we posited that, following supportive journaling tasks, caregivers of spouses currently managing a cancer experience would report greater motivation but also greater difficulty in generating high-quality support messages, while individuals caring for a patient in remission would report lower motivation but greater ability to create high-quality support messages. Findings provided support for these assertions and suggested that reflective journaling tasks might be a useful tool for improving remission caregivers' ability to provide high-quality social support to survivors. Corresponding theoretical and applied implications are discussed.

  3. Short Communication - Study on quality and efficacy of commercial tylosin and doxycycline products against local isolates of mycoplasma in broilers.

    PubMed

    Riazuddin, -; Khan, Sarzamin; Imtiaz, Naila; Aslam, Saima; Ahmad, Shakoor; Khan, Hamayun; Rabbani, Masood; Muhammad, Javed; Tanveer, Zafar Iqbal; Ali, Sakhawat

    2017-03-01

    The present study was conducted to investigate the quality and efficacy of commercially available preparations of tylosin and doxycycline available in the local market at Peshawar for poultry. In vitro and in vivo, tests were conducted to check the quality of these antimicrobial drugs. In vitro quality control test was performed by High performance liquid chromatographic (HPLC) and micro dilution method. In vivo, efficacy of the test drugs was checked in broilers infected with Mycoplasma gallisepticum. Results of HPLC indicated that test drug-2 contains doxycycline hydrochloride within specified limits but contain high quantity of active ingredient (Tylosin tartrate 120%). Recovery percentage of test drugs (3, 4, 5) were below the pharmacopoeial limit, which contained low quantity of tylosin tartrate (85%, 87.5%, 85%) respectively however, percent recovery of doxycycline were in the appropriate limits. All the tested drugs were effective against Mycoplasma gallisepticum and showed minimum inhibitory concentration (MIC) at 1.9μg/ml. The in vivo result indicated that all tested drugs decreased morbidity and mortality in infected chicks. The birds treated with test drugs (3 and 5) showed mortality of 9.5%, which was slightly higher than the other test groups. The current study suggested that there are incidences of substandard drugs in Pakistan and the drug regularity authorities should take strict actions against the manufacturing companies.

  4. Flight test of the X-29A at high angle of attack: Flight dynamics and controls

    NASA Technical Reports Server (NTRS)

    Bauer, Jeffrey E.; Clarke, Robert; Burken, John J.

    1995-01-01

    The NASA Dryden Flight Research Center has flight tested two X-29A aircraft at low and high angles of attack. The high-angle-of-attack tests evaluate the feasibility of integrated X-29A technologies. More specific objectives focus on evaluating the high-angle-of-attack flying qualities, defining multiaxis controllability limits, and determining the maximum pitch-pointing capability. A pilot-selectable gain system allows examination of tradeoffs in airplane stability and maneuverability. Basic fighter maneuvers provide qualitative evaluation. Bank angle captures permit qualitative data analysis. This paper discusses the design goals and approach for high-angle-of-attack control laws and provides results from the envelope expansion and handling qualities testing at intermediate angles of attack. Comparisons of the flight test results to the predictions are made where appropriate. The pitch rate command structure of the longitudinal control system is shown to be a valid design for high-angle-of-attack control laws. Flight test results show that wing rock amplitude was overpredicted and aileron and rudder effectiveness were underpredicted. Flight tests show the X-29A airplane to be a good aircraft up to 40 deg angle of attack.

  5. Trampoline Resonator Fabrication for Tests of Quantum Mechanics at High Mass

    NASA Astrophysics Data System (ADS)

    Weaver, Matthew; Pepper, Brian; Sonin, Petro; Eerkens, Hedwig; Buters, Frank; de Man, Sven; Bouwmeester, Dirk

    2014-03-01

    There has been much interest recently in optomechanical devices that can reach the ground state. Two requirements for achieving ground state cooling are high optical finesse in the cavity and high mechanical quality factor. We present a set of trampoline resonator devices using high stress silicon nitride and superpolishing of mirrors with sufficient finesse (as high as 60,000) and quality factor (as high as 480,000) for ground state cooling in a dilution refrigerator. These devices have a higher mass, between 80 and 100 ng, and lower frequency, between 200 and 500 kHz, than other devices that have been cooled to the ground state, enabling tests of quantum mechanics at a larger mass scale.

  6. [Quality of the Early Cervical Cancer Detection Program in the State of Nuevo León].

    PubMed

    Salinas-Martínez, A M; Villarreal-Ríos, E; Garza-Elizondo, M E; Fraire-Gloria, J M; López-Franco, J J; Barboza-Quintana, O

    1997-01-01

    To determine the quality of the Early Cervical Cancer Detection Program in the state of Nuevo León. A random selection of 4791 cytologic reports were analyzed, emitted by the State Ministry of Health, the University Hospital and the Mexican Institute for Social Security early cervical cancer detection modules. Pap tests of women with hysterectomy, current pregnancy, menopause or positive result were excluded. Quality was measured with previously defined standards. Analysis included, besides univariate statistics, tests of significance for proportions and means. The quality of the program was fairly satisfactory at the level of the State. The quality of the sampling procedure was low; 39.9% of the tests contained endocervical cells. Quality of coverage was low; 15.6% were women 25+years with first time Pap test. Quality of opportunity was high; 8.5 +/- 7 weekdays between the date of the pap smear and the interpretation date. Strategies are needed to increase the impact of the state program, such as improving the sampling procedure and the coverage quality levels.

  7. Optimal Item Pool Design for a Highly Constrained Computerized Adaptive Test

    ERIC Educational Resources Information Center

    He, Wei

    2010-01-01

    Item pool quality has been regarded as one important factor to help realize enhanced measurement quality for the computerized adaptive test (CAT) (e.g., Flaugher, 2000; Jensema, 1977; McBride & Wise, 1976; Reckase, 1976; 2003; van der Linden, Ariel, & Veldkamp, 2006; Veldkamp & van der Linden, 2000; Xing & Hambleton, 2004). However, studies are…

  8. Psychometric evaluation of commonly used game-specific skills tests in rugby: A systematic review

    PubMed Central

    Oorschot, Sander; Chiwaridzo, Matthew; CM Smits-Engelsman, Bouwien

    2017-01-01

    Objectives To (1) give an overview of commonly used game-specific skills tests in rugby and (2) evaluate available psychometric information of these tests. Methods The databases PubMed, MEDLINE CINAHL and Africa Wide information were systematically searched for articles published between January 1995 and March 2017. First, commonly used game-specific skills tests were identified. Second, the available psychometrics of these tests were evaluated and the methodological quality of the studies assessed using the Consensus-based Standards for the selection of health Measurement Instruments checklist. Studies included in the first step had to report detailed information on the construct and testing procedure of at least one game-specific skill, and studies included in the second step had additionally to report at least one psychometric property evaluating reliability, validity or responsiveness. Results 287 articles were identified in the first step, of which 30 articles met the inclusion criteria and 64 articles were identified in the second step of which 10 articles were included. Reactive agility, tackling and simulated rugby games were the most commonly used tests. All 10 studies reporting psychometrics reported reliability outcomes, revealing mainly strong evidence. However, all studies scored poor or fair on methodological quality. Four studies reported validity outcomes in which mainly moderate evidence was indicated, but all articles had fair methodological quality. Conclusion Game-specific skills tests indicated mainly high reliability and validity evidence, but the studies lacked methodological quality. Reactive agility seems to be a promising domain, but the specific tests need further development. Future high methodological quality studies are required in order to develop valid and reliable test batteries for rugby talent identification. Trial registration number PROSPERO CRD42015029747. PMID:29259812

  9. Development of Reasoning Test Instruments Based on TIMSS Framework for Measuring Reasoning Ability of Senior High School Student on the Physics Concept

    NASA Astrophysics Data System (ADS)

    Muslim; Suhandi, A.; Nugraha, M. G.

    2017-02-01

    The purposes of this study are to determine the quality of reasoning test instruments that follow the framework of Trends in International Mathematics and Science Study (TIMSS) as a development results and to analyse the profile of reasoning skill of senior high school students on physics materials. This research used research and development method (R&D), furthermore the subject were 104 students at three senior high schools in Bandung selected by random sampling technique. Reasoning test instruments are constructed following the TIMSS framework in multiple choice forms in 30 questions that cover five subject matters i.e. parabolic motion and circular motion, Newton’s law of gravity, work and energy, harmonic oscillation, as well as the momentum and impulse. The quality of reasoning tests were analysed using the Content Validity Ratio (CVR) and classic test analysis include the validity of item, level of difficulty, discriminating power, reliability and Ferguson’s delta. As for the students’ reasoning skills profiles were analysed by the average score of achievements on eight aspects of the reasoning TIMSS framework. The results showed that reasoning test have a good quality as instruments to measure reasoning skills of senior high school students on five matters physics which developed and able to explore the reasoning of students on all aspects of reasoning based on TIMSS framework.

  10. Characteristics of High-Quality Teachers

    ERIC Educational Resources Information Center

    Jones, Jason E.; Gulek, James C.

    2010-01-01

    The purpose of this study was to examine the characteristics of high-quality teachers who used a structured mathematics program for teaching, namely the Math Achievement Program (MAP[superscript 2]D), which demonstrated significant gains on student achievement as measured by California's Standards Test (CST) in mathematics. Specifically, the…

  11. Mere exposure effect: A consequence of direct and indirect fluency-preference links.

    PubMed

    Willems, Sylvie; Van der Linden, Martial

    2006-06-01

    In three experiments, picture quality between test items was manipulated to examine whether subjects' expectations about the fluency normally associated with these different stimuli might influence the effects of fluency on preference or familiarity-based recognition responses. The results showed that fluency due to pre-exposure influenced responses less when objects were presented with high picture quality, suggesting that attributions of fluency to preference and familiarity are adjusted according to expectations about the different test pictures. However, this expectations influence depended on subjects' awareness of these different quality levels. Indeed, imperceptible differences seemed not to induce expectations about the test item fluency. In this context, fluency due to both picture quality and pre-exposure influenced direct responses. Conversely, obvious, and noticed, differences in test picture quality did no affect responses, suggesting that expectations moderated attributions of fluency only when fluency normally associated with these different stimuli was perceptible but difficult to assess.

  12. Strengthening the Assessment Trajectory: Engaging Educators in the Policy Process. Making a Measurable Difference: Case Studies from the High-Quality Assessment Project

    ERIC Educational Resources Information Center

    McClellan, Catherine; Snyder, Rebecca; Woods-Murphy, Maryann; Basset, Katherine

    2018-01-01

    Great teachers recognize great assessments. As policy and education leaders work to make sure state tests are measuring the problem-solving, writing, and critical-thinking skills students need for success, they should convene and rely on teachers to review test quality and help answer the question: Do the questions on our state test reflect…

  13. High-Stakes Testing in the Warm Heart of Africa: The Challenges and Successes of the Malawi National Examinations Board

    ERIC Educational Resources Information Center

    Chakwera, Elias; Khembo, Dafter; Sireci, Stephen G.

    2004-01-01

    In the United States, tests are held to high standards of quality. In developing countries such as Malawi, psychometricians must deal with these same high standards as well as several additional pressures such as widespread cheating, test administration difficulties due to challenging landscapes and poor resources, difficulties in reliably scoring…

  14. Advanced Capabilities for Wind Tunnel Testing in the 21st Century

    NASA Technical Reports Server (NTRS)

    Kegelman, Jerome T.; Danehy, Paul M.; Schwartz, Richard J.

    2010-01-01

    Wind tunnel testing methods and test technologies for the 21st century using advanced capabilities are presented. These capabilities are necessary to capture more accurate and high quality test results by eliminating the uncertainties in testing and to facilitate verification of computational tools for design. This paper discusses near term developments underway in ground testing capabilities, which will enhance the quality of information of both the test article and airstream flow details. Also discussed is a selection of new capability investments that have been made to accommodate such developments. Examples include advanced experimental methods for measuring the test gas itself; using efficient experiment methodologies, including quality assurance strategies within the test; and increasing test result information density by using extensive optical visualization together with computed flow field results. These points could be made for both major investments in existing tunnel capabilities or for entirely new capabilities.

  15. Predicting sport and occupational lower extremity injury risk through movement quality screening: a systematic review.

    PubMed

    Whittaker, Jackie L; Booysen, Nadine; de la Motte, Sarah; Dennett, Liz; Lewis, Cara L; Wilson, Dave; McKay, Carly; Warner, Martin; Padua, Darin; Emery, Carolyn A; Stokes, Maria

    2017-04-01

    Identification of risk factors for lower extremity (LE) injury in sport and military/first-responder occupations is required to inform injury prevention strategies. To determine if poor movement quality is associated with LE injury in sport and military/first-responder occupations. 5 electronic databases were systematically searched. Studies selected included original data; analytic design; movement quality outcome (qualitative rating of functional compensation, asymmetry, impairment or efficiency of movement control); LE injury sustained with sport or military/first-responder occupation. The Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines were followed. 2 independent authors assessed the quality (Downs and Black (DB) criteria) and level of evidence (Oxford Centre of Evidence-Based Medicine model). Of 4361 potential studies, 17 were included. The majority were low-quality cohort studies (level 4 evidence). Median DB score was 11/33 (range 3-15). Heterogeneity in methodology and injury definition precluded meta-analyses. The Functional Movement Screen was the most common outcome investigated (15/17 studies). 4 studies considered inter-relationships between risk factors, 7 reported diagnostic accuracy and none tested an intervention programme targeting individuals identified as high risk. There is inconsistent evidence that poor movement quality is associated with increased risk of LE injury in sport and military/first-responder occupations. Future research should focus on high-quality cohort studies to identify the most relevant movement quality outcomes for predicting injury risk followed by developing and evaluating preparticipation screening and LE injury prevention programmes through high-quality randomised controlled trials targeting individuals at greater risk of injury based on screening tests with validated test properties. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Predicting Sport and Occupational Lower Extremity Injury Risk through Movement Quality Screening: A Systematic Review

    PubMed Central

    Whittaker, Jackie L; Booysen, Nadine; de la Motte, Sarah; Dennett, Liz; Lewis, Cara L.; Wilson, Dave; McKay, Carly; Warner, Martin; Padua, Darin; Emery, Carolyn A; Stokes, Maria

    2017-01-01

    Background Identification of risk factors for lower extremity (LE) injury in sport and military/first-responder occupations is required to inform injury prevention strategies. Objective To determine if poor movement quality is associated with LE injury in sport and military/first-responder occupations. Material and methods Five electronic databases were systematically searched. Studies selected included: original data; analytic design; movement quality outcome (qualitative rating of functional compensation, asymmetry, impairment or efficiency of movement control); LE injury sustained with sport or military/first-responder occupation. The PRISMA guidelines were followed. Two independent authors assessed the quality [Downs and Black (DB) criteria] and level of evidence (Oxford Centre of Evidence-Based Medicine model). Results Of 4361 potential studies, 17 were included. The majority were low quality cohort studies (level 4 evidence). Median DB score was 11/33 (range 3–15). Heterogeneity in methodology and injury definition precluded meta-analyses. The Functional Movement Screen was the most common outcome investigated (15/17 studies). Four studies considered interrelationships between risk factors, seven reported diagnostic accuracy and none tested an intervention program targeting individuals identified as high-risk. There is inconsistent evidence that poor movement quality is associated with increased risk of LE injury in sport and military/first-responder occupations. Conclusions Future research should focus on high quality cohort studies to identify the most relevant movement quality outcomes for predicting injury risk followed by developing and evaluating pre-participation screening and LE injury prevention programs through high quality randomized controlled trials targeting individuals at greater risk of injury based upon screening tests with validated test properties. PMID:27935483

  17. Raising Teacher Quality around the World

    ERIC Educational Resources Information Center

    Stewart, Vivien

    2011-01-01

    Contrary to what many people assume, writes Stewart, a high-quality teacher workforce is not the simple result of some traditional cultural respect for teachers that exists in some countries. Rather, it requires deliberate policy choices. In a tour of seven countries that traditionally score high on international tests of student performance…

  18. Testing, Requirements, and Metrics

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda; Hyatt, Larry; Hammer, Theodore F.; Huffman, Lenore; Wilson, William

    1998-01-01

    The criticality of correct, complete, testable requirements is a fundamental tenet of software engineering. Also critical is complete requirements based testing of the final product. Modern tools for managing requirements allow new metrics to be used in support of both of these critical processes. Using these tools, potential problems with the quality of the requirements and the test plan can be identified early in the life cycle. Some of these quality factors include: ambiguous or incomplete requirements, poorly designed requirements databases, excessive or insufficient test cases, and incomplete linkage of tests to requirements. This paper discusses how metrics can be used to evaluate the quality of the requirements and test to avoid problems later. Requirements management and requirements based testing have always been critical in the implementation of high quality software systems. Recently, automated tools have become available to support requirements management. At NASA's Goddard Space Flight Center (GSFC), automated requirements management tools are being used on several large projects. The use of these tools opens the door to innovative uses of metrics in characterizing test plan quality and assessing overall testing risks. In support of these projects, the Software Assurance Technology Center (SATC) is working to develop and apply a metrics program that utilizes the information now available through the application of requirements management tools. Metrics based on this information provides real-time insight into the testing of requirements and these metrics assist the Project Quality Office in its testing oversight role. This paper discusses three facets of the SATC's efforts to evaluate the quality of the requirements and test plan early in the life cycle, thus preventing costly errors and time delays later.

  19. Local extinction of dragonfly and damselfly populations in low- and high-quality habitat patches.

    PubMed

    Suhonen, Jukka; Hilli-Lukkarinen, Milla; Korkeamäki, Esa; Kuitunen, Markku; Kullas, Johanna; Penttinen, Jouni; Salmela, Jukka

    2010-08-01

    Understanding the risk of extinction of a single population is an important problem in both theoretical and applied ecology. Local extinction risk depends on several factors, including population size, demographic or environmental stochasticity, natural catastrophe, or the loss of genetic diversity. The probability of local extinction may also be higher in low-quality sink habitats than in high-quality source habitats. We tested this hypothesis by comparing local extinction rates of 15 species of Odonata (dragonflies and damselflies) between 1930-1975 and 1995-2003 in central Finland. Local extinction rates were higher in low-quality than in high-quality habitats. Nevertheless, for the three most common species there were no differences in extinction rates between low- and high-quality habitats. Our results suggest that a good understanding of habitat quality is crucial for the conservation of species in heterogeneous landscapes.

  20. Instrumental Surveillance of Water Quality.

    ERIC Educational Resources Information Center

    Miller, J. A.; And Others

    The role analytical instrumentation performs in the surveillance and control of the quality of water resources is reviewed. Commonly performed analyses may range from simple tests for physical parameters to more highly sophisticated radiological or spectrophotometric methods. This publication explores many of these types of water quality analyses…

  1. Linking nurses' perceptions of patient care quality to job satisfaction: the role of authentic leadership and empowering professional practice environments.

    PubMed

    Spence Laschinger, Heather K; Fida, Roberta

    2015-05-01

    A model linking authentic leadership, structural empowerment, and supportive professional practice environments to nurses' perceptions of patient care quality and job satisfaction was tested. Positive work environment characteristics are important for nurses' perceptions of patient care quality and job satisfaction (significant factors for retention). Few studies have examined the mechanism by which these characteristics operate to influence perceptions of patient care quality or job satisfaction. A cross-sectional provincial survey of 723 Canadian nurses was used to test the hypothesized models using structural equation modeling. The model was an acceptable fit and all paths were significant. Authentic leadership had a positive effect on structural empowerment, which had a positive effect on perceived support for professional practice and a negative effect on nurses' perceptions that inadequate unit staffing prevented them from providing high-quality patient care. These workplace conditions predicted job satisfaction. Authentic leaders play an important role in creating empowering professional practice environments that foster high-quality care and job satisfaction.

  2. What's to Be Done About Laboratory Quality? Process Indicators, Laboratory Stewardship, the Outcomes Problem, Risk Assessment, and Economic Value: Responding to Contemporary Global Challenges.

    PubMed

    Meier, Frederick A; Badrick, Tony C; Sikaris, Kenneth A

    2018-02-17

    For 50 years, structure, process, and outcomes measures have assessed health care quality. For clinical laboratories, structural quality has generally been assessed by inspection. For assessing process, quality indicators (QIs), statistical monitors of steps in the clinical laboratory total testing, have proliferated across the globe. Connections between structural and process laboratory measures and patient outcomes, however, have rarely been demonstrated. To inform further development of clinical laboratory quality systems, we conducted a selective but worldwide review of publications on clinical laboratory quality assessment. Some QIs, like seven generic College of American Pathologists Q-Tracks monitors, have demonstrated significant process improvement; other measures have uncovered critical opportunities to improve test selection and result management. The College of Pathologists of Australasia Key Indicator Monitoring and Management System has deployed risk calculations, introduced from failure mode effects analysis, as surrogate measures for outcomes. Showing economic value from clinical laboratory testing quality is a challenge. Clinical laboratories should converge on fewer (7-14) rather than more (21-35) process monitors; monitors should cover all steps of the testing process under laboratory control and include especially high-risk specimen-quality QIs. Clinical laboratory stewardship, the combination of education interventions among clinician test orderers and report consumers with revision of test order formats and result reporting schemes, improves test ordering, but improving result reception is more difficult. Risk calculation reorders the importance of quality monitors by balancing three probabilities: defect frequency, weight of potential harm, and detection difficulty. The triple approach of (1) a more focused suite of generic consensus quality indicators, (2) more active clinical laboratory testing stewardship, and (3) integration of formal risk assessment, rather than competing with economic value, enhances it.

  3. Quality specifications for articles of botanical origin from the United States Pharmacopeia.

    PubMed

    Ma, Cuiying; Oketch-Rabah, Hellen; Kim, Nam-Cheol; Monagas, Maria; Bzhelyansky, Anton; Sarma, Nandakumara; Giancaspro, Gabriel

    2018-06-01

    In order to define appropriate quality of botanical dietary supplements, botanical drugs, and herbal medicines, the United States Pharmacopeia (USP) and the Herbal Medicines Compendium (HMC) contain science-based quality standards that include multiple interrelated tests to provide a full quality characterization for each article in terms of its identity, purity, and content. To provide a comprehensive description of the pharmacopeial tests and requirements for articles of botanical origin in the aforementioned compendia. Selective chromatographic procedures, such as high-performance liquid chromatography (HPLC) and high-performance thin-layer chromatography (HPTLC), are used as Identification tests in pharmacopeial monographs to detect species substitution or other confounders. HPLC quantitative tests are typically used to determine the content of key constituents, i.e., the total or individual amount of plant secondary metabolites that are considered bioactive constituents or analytical marker compounds. Purity specifications are typically set to limit the content of contaminants such as toxic elements, pesticides, and fungal toxins. Additional requirements highlight the importance of naming, definition, use of reference materials, and packaging/storage conditions. Technical requirements for each section of the monographs were illustrated with specific examples. Tests were performed on authentic samples using pharmacopeial reference standards. The chromatographic analytical procedures were validated to provide characteristic profiles for the identity and/or accurate determination of the content of quality markers. The multiple tests included in each monograph complement each other to provide an appropriate pharmacopeial quality characterization for the botanicals used as herbal medicines and dietary supplements. The monographs provide detailed specifications for identity, content of bioactive constituents or quality markers, and limits of contaminants, adulterants, and potentially toxic substances. Additional requirements such as labeling and packaging further contribute to preserve the quality of these products. Compliance with pharmacopeial specifications should be required to ensure the reliability of botanical articles used for health care purposes. Copyright © 2018. Published by Elsevier GmbH.

  4. Assessing personality in San Joaquin kit fox in situ: efficacy of field-based experimental methods and implications for conservation management.

    PubMed

    Bremner-Harrison, Samantha; Cypher, Brian L; Van Horn Job, Christine; Harrison, Stephen W R

    2018-01-01

    Utilisation of animal personality has potential benefit for conservation management. Due to logistics of robust behavioural evaluation in situ, the majority of studies on wild animals involve taking animals into captivity for testing, potentially compromising results. Three in situ tests for evaluation of boldness in San Joaquin kit fox ( Vulpes macrotis mutica ) were developed (ENOT: extended novel object test; RNOT: rapid novel object test; TH: trap/handling test). Each test successfully identified variation in boldness within its target age class(es). The TH test was suitable for use across all age classes. Tests were assessed for in situ suitability and for quantity/quality of data yielded. ENOT was rated as requiring high levels of time, cost and labour with greater likelihood of failure. However, it was rated highly for data quantity/quality. The TH test was rated as requiring little time, labour and cost, but yielding lower quality data. RNOT was rated in the middle. Each test had merit and could be adapted to suit project or species constraints. We recommend field-based evaluation of personality, reducing removal of animals from the wild and facilitating routine incorporation of personality assessment into conservation projects.

  5. Melter Throughput Enhancements for High-Iron HLW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, A. A.; Gan, Hoa; Joseph, Innocent

    2012-12-26

    This report describes work performed to develop and test new glass and feed formulations in order to increase glass melting rates in high waste loading glass formulations for HLW with high concentrations of iron. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and to develop new formulations with enhanced melt rate. Testing evaluated the effects of waste loading on glass properties and themore » maximum waste loading that can be achieved. The results from crucible-scale testing supported subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass and feed formulations on waste processing rate and product quality. The DM100 was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions.« less

  6. Evaluation of differences in quality of experience features for test stimuli of good-only and bad-only overall audiovisual quality

    NASA Astrophysics Data System (ADS)

    Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith

    2013-01-01

    Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.

  7. Links among high-performance work environment, service quality, and customer satisfaction: an extension to the healthcare sector.

    PubMed

    Scotti, Dennis J; Harmon, Joel; Behson, Scott J

    2007-01-01

    Healthcare managers must deliver high-quality patient services that generate highly satisfied and loyal customers. In this article, we examine how a high-involvement approach to the work environment of healthcare employees may lead to exceptional service quality, satisfied patients, and ultimately to loyal customers. Specifically, we investigate the chain of events through which high-performance work systems (HPWS) and customer orientation influence employee and customer perceptions of service quality and patient satisfaction in a national sample of 113 Veterans Health Administration ambulatory care centers. We present a conceptual model for linking work environment to customer satisfaction and test this model using structural equations modeling. The results suggest that (1) HPWS is linked to employee perceptions of their ability to deliver high-quality customer service, both directly and through their perceptions of customer orientation; (2) employee perceptions of customer service are linked to customer perceptions of high-quality service; and (3) perceived service quality is linked with customer satisfaction. Theoretical and practical implications of our findings, including suggestions of how healthcare managers can implement changes to their work environments, are discussed.

  8. Reliability of the Melbourne assessment of unilateral upper limb function.

    PubMed

    Randall, M; Carlin, J B; Chondros, P; Reddihough, D

    2001-11-01

    This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.

  9. High-Rank Stakeholders' Perspectives on High-Stakes University Entrance Examinations Reform: Priorities and Problems

    ERIC Educational Resources Information Center

    Kiany, Gholam Reza; Shayestefar, Parvaneh; Samar, Reza Ghafar; Akbari, Ramin

    2013-01-01

    A steady stream of studies on high-stakes tests such as University Entrance Examinations (UEEs) suggests that high-stakes tests reforms serve as the leverage for promoting quality of learning, standards of teaching, and credible forms of accountability. However, such remediation is often not as effective as hoped and success is not necessarily…

  10. Analysis of visual quality improvements provided by known tools for HDR content

    NASA Astrophysics Data System (ADS)

    Kim, Jaehwan; Alshina, Elena; Lee, JongSeok; Park, Youngo; Choi, Kwang Pyo

    2016-09-01

    In this paper, the visual quality of different solutions for high dynamic range (HDR) compression using MPEG test contents is analyzed. We also simulate the method for an efficient HDR compression which is based on statistical property of the signal. The method is compliant with HEVC specification and also easily compatible with other alternative methods which might require HEVC specification changes. It was subjectively tested on commercial TVs and compared with alternative solutions for HDR coding. Subjective visual quality tests were performed using SUHD TVs model which is SAMSUNG JS9500 with maximum luminance up to 1000nit in test. The solution that is based on statistical property shows not only improvement of objective performance but improvement of visual quality compared to other HDR solutions, while it is compatible with HEVC specification.

  11. Fully Funding Pre-K through K-12 Funding Formulas

    ERIC Educational Resources Information Center

    Barnett, W. Steven; Kasmin, Richard

    2018-01-01

    Pre-K is widely acknowledged to be a sound public investment. When their pre-K programs are of high quality, disadvantaged children see particularly large benefits--higher test scores, less need for grade repetition and special education, and increased educational attainment. Yet high-quality programs are in short supply. State boards of education…

  12. High-quality JPEG compression history detection for fake uncompressed images

    NASA Astrophysics Data System (ADS)

    Zhang, Rong; Wang, Rang-Ding; Guo, Li-Jun; Jiang, Bao-Chuan

    2017-05-01

    Authenticity is one of the most important evaluation factors of images for photography competitions or journalism. Unusual compression history of an image often implies the illicit intent of its author. Our work aims at distinguishing real uncompressed images from fake uncompressed images that are saved in uncompressed formats but have been previously compressed. To detect the potential image JPEG compression, we analyze the JPEG compression artifacts based on the tetrolet covering, which corresponds to the local image geometrical structure. Since the compression can alter the structure information, the tetrolet covering indexes may be changed if a compression is performed on the test image. Such changes can provide valuable clues about the image compression history. To be specific, the test image is first compressed with different quality factors to generate a set of temporary images. Then, the test image is compared with each temporary image block-by-block to investigate whether the tetrolet covering index of each 4×4 block is different between them. The percentages of the changed tetrolet covering indexes corresponding to the quality factors (from low to high) are computed and used to form the p-curve, the local minimum of which may indicate the potential compression. Our experimental results demonstrate the advantage of our method to detect JPEG compressions of high quality, even the highest quality factors such as 98, 99, or 100 of the standard JPEG compression, from uncompressed-format images. At the same time, our detection algorithm can accurately identify the corresponding compression quality factor.

  13. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    NASA Astrophysics Data System (ADS)

    Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R. M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y. G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J. A.; Mitselmakher, G.; Mohanty, A. K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M. S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A. H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S. K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2018-02-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  14. MPEG-2 Over Asynchronous Transfer Mode (ATM) Over Satellite Quality of Service (QoS) Experiments: Laboratory Tests

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.; Frantz, Brian D.; Spells, Marcus J.

    1998-01-01

    Asynchronous transfer mode (ATM) quality of service (QoS) experiments were performed using MPEG-2 (ATM application layer 5, AAL5) over ATM over an emulated satellite link. The purpose of these experiments was to determine the free-space link quality necessary to transmit high-quality multimedia information by using the ATM protocol. The detailed test plan and test configuration are described herein as are the test results. MPEG-2 transport streams were baselined in an errored environment, followed by a series of tests using, MPEG-2 over ATM. Errors were created both digitally as well as in an IF link by using a satellite modem and commercial gaussian noise test set for two different MPEG-2 decoder implementations. The results show that ITU-T Recommendation 1.356 Class 1, stringent ATM applications will require better link quality than currently specified; in particular, cell loss ratios of better than 1.0 x 10(exp -8) and cell error ratios of better than 1.0 x 10(exp -7) are needed. These tests were conducted at the NASA Lewis Research Center in support of satellite-ATM interoperability research.

  15. With Home Testing, Consumers Take Charge of Their Health

    MedlinePlus

    ... Mutation Mycophenolic Acid Mycoplasma Myoglobin Nicotine and Cotinine Non-High Density Lipoprotein Cholesterol Opioid Testing Osmolality Ova ... at the bedside," Nichols says, "but not necessarily equivalent to the quality of testing performed in a ...

  16. Testing and validation of computerized decision support systems.

    PubMed

    Sailors, R M; East, T D; Wallace, C J; Carlson, D A; Franklin, M A; Heermann, L K; Kinder, A T; Bradshaw, R L; Randolph, A G; Morris, A H

    1996-01-01

    Systematic, through testing of decision support systems (DSSs) prior to release to general users is a critical aspect of high quality software design. Omission of this step may lead to the dangerous, and potentially fatal, condition of relying on a system with outputs of uncertain quality. Thorough testing requires a great deal of effort and is a difficult job because tools necessary to facilitate testing are not well developed. Testing is a job ill-suited to humans because it requires tireless attention to a large number of details. For these reasons, the majority of DSSs available are probably not well tested prior to release. We have successfully implemented a software design and testing plan which has helped us meet our goal of continuously improving the quality of our DSS software prior to release. While requiring large amounts of effort, we feel that the process of documenting and standardizing our testing methods are important steps toward meeting recognized national and international quality standards. Our testing methodology includes both functional and structural testing and requires input from all levels of development. Our system does not focus solely on meeting design requirements but also addresses the robustness of the system and the completeness of testing.

  17. High Density Aerial Image Matching: State-Of and Future Prospects

    NASA Astrophysics Data System (ADS)

    Haala, N.; Cavegn, S.

    2016-06-01

    Ongoing innovations in matching algorithms are continuously improving the quality of geometric surface representations generated automatically from aerial images. This development motivated the launch of the joint ISPRS/EuroSDR project "Benchmark on High Density Aerial Image Matching", which aims on the evaluation of photogrammetric 3D data capture in view of the current developments in dense multi-view stereo-image matching. Originally, the test aimed on image based DSM computation from conventional aerial image flights for different landuse and image block configurations. The second phase then put an additional focus on high quality, high resolution 3D geometric data capture in complex urban areas. This includes both the extension of the test scenario to oblique aerial image flights as well as the generation of filtered point clouds as additional output of the respective multi-view reconstruction. The paper uses the preliminary outcomes of the benchmark to demonstrate the state-of-the-art in airborne image matching with a special focus of high quality geometric data capture in urban scenarios.

  18. Modeling the Effects of Conservation Tillage on Water Quality at the Field Scale

    USDA-ARS?s Scientific Manuscript database

    The development and application of predictive tools to quantitatively assess the effects of tillage and related management activities should be carefully tested against high quality field data. This study reports on: 1) the calibration and validation of the Root Zone Water Quality Model (RZWQM) to a...

  19. Humanising Language Testing

    ERIC Educational Resources Information Center

    Hamid, M. Obaidul; Hoang, Ngoc T. H.

    2018-01-01

    Test-takers' voices in relation to high-stakes language tests have received growing attention in recent years. While the perspectives of this stakeholder group can be utilised to improve test quality, test-taking experience, and test impact, we argue that this goal needs to be achieved by considering a fundamental shift in our conceptualisation of…

  20. Test/QA plan for the validation of the verification protocol for high speed pesticide spray drift reduction technologies for row and field crops

    EPA Science Inventory

    This test/QA plan for evaluation the generic test protocol for high speed wind tunnel, representing aerial application, pesticide spray drift reduction technologies (DRT) for row and field crops is in conformance with EPA Requirements for Quality Assurance Project Plans (EPA QA/R...

  1. Human Milk-Treatment and Quality of Banked Human Milk.

    PubMed

    Picaud, Jean-Charles; Buffin, Rachel

    2017-03-01

    The aim of human milk banks is to deliver safe and high quality donor human milk. Treatment of human milk has to destroy most microorganisms while preserving immunological and nutrient components, which is obtained when using low time low temperature pasteurization. However it destroys bile-simulated lipase, reduces lactoferrin, lysozyme, immunoglobulins, and bactericidal capacity of human milk. New methods are under investigation such as high temperature short time pasteurization, high pressure processing, or ultraviolet irradiation. They have been tested in experimental conditions and there are promising results, but they have to be tested in real conditions in human milk bank. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    PubMed

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn screening laboratories. The recommended practices address the benefits of using a quality management system approach, factors to consider before introducing new tests, establishment and verification of test performance specifications, the total laboratory testing process (which consists of the preanalytic, analytic, and postanalytic phases), confidentiality of patient information and test results, and personnel qualifications and responsibilities for laboratory testing for inherited metabolic diseases. These recommendations are intended for laboratories that perform biochemical genetic testing to improve the quality of laboratory services and for newborn screening laboratories to ensure the quality of laboratory practices for inherited metabolic disorders. These recommendations also are intended as a resource for medical and public health professionals who evaluate laboratory practices, for users of laboratory services to facilitate their collaboration with newborn screening systems and use of biochemical genetic tests, and for standard-setting organizations and professional societies in developing future laboratory quality standards and practice recommendations. This report complements Good Laboratory Practices for Molecular Genetic Testing for Heritable Diseases and Conditions (CDC. Good laboratory practices for molecular genetic testing for heritable diseases and conditions. MMWR 2009;58 [No. RR-6]) to provide guidance for ensuring and improving the quality of genetic laboratory services and public health outcomes. Future recommendations for additional areas of genetic testing will be considered on the basis of continued monitoring and evaluation of laboratory practices, technology advancements, and the development of laboratory standards and guidelines.

  3. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    PubMed

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  4. Progress in Flaps Down Flight Reynolds Number Testing Techniques at the NTF

    NASA Technical Reports Server (NTRS)

    Payne, Frank; Bosetti, Cris; Gatlin, Greg; Tuttle, Dave; Griffiths, Bob

    2007-01-01

    A series of NASA/Boeing cooperative low speed wind tunnel tests was conducted in the National Transonic Facility (NTF) between 2003 and 2004 using a semi-span high lift model representative of the 777-200 aircraft. The objective of this work was to develop the capability to acquire high quality, low speed (flaps down) wind tunnel data at up to flight Reynolds numbers in a facility originally optimized for high speed full span models. In the course of testing, a number of facility and procedural improvements were identified and implemented. The impact of these improvements on key testing metrics data quality, productivity, and so forth - was significant, and is discussed here, together with the relevance of these metrics as applied to cryogenic wind tunnel testing in general. Details of the improvements at the NTF are discussed in AIAA-2006-0508 (Recent Improvements in Semi-span Testing at the National Transonic Facility). The development work at the NTF culminated with validation testing of a 787-8 semi-span model at full flight Reynolds number in the first quarter of 2006.

  5. How to conduct a high-quality original study on a diagnostic research topic.

    PubMed

    Yao, Xiaomei; Vella, Emily

    2017-09-01

    As health research methodologists and journal reviewers, we noticed that the methodological rigor of many publications on diagnostic or prognostic topics in the medical literature could be improved. We present a concise and clear series of reviews to help clinicians and health researchers to master the basic key components of how to conduct a high-quality original study or systematic review on a diagnostic or prognostic research topic from a methodological perspective. This is the first review of the series, which focuses on how to conduct a high-quality diagnostic study. We are introducing four aspects: clarifying the objectives; generating an appropriate research question; planning the study design; and reporting and analyzing data. This review highlights that diagnostic test accuracy outcomes are surrogates for patient outcomes, a diagnostic test has three roles, the "PIRO" components should be included in a diagnostic research question, a new study should be registered, multiple index tests can be compared in one study, and prevalence affects test accuracy outcomes. This review also emphasizes reporting any thresholds, calculating sample size, and performing a two-by-three table to calculate diagnostic outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. CUQI: cardiac ultrasound video quality index

    PubMed Central

    Razaak, Manzoor; Martini, Maria G.

    2016-01-01

    Abstract. Medical images and videos are now increasingly part of modern telecommunication applications, including telemedicinal applications, favored by advancements in video compression and communication technologies. Medical video quality evaluation is essential for modern applications since compression and transmission processes often compromise the video quality. Several state-of-the-art video quality metrics used for quality evaluation assess the perceptual quality of the video. For a medical video, assessing quality in terms of “diagnostic” value rather than “perceptual” quality is more important. We present a diagnostic-quality–oriented video quality metric for quality evaluation of cardiac ultrasound videos. Cardiac ultrasound videos are characterized by rapid repetitive cardiac motions and distinct structural information characteristics that are explored by the proposed metric. Cardiac ultrasound video quality index, the proposed metric, is a full reference metric and uses the motion and edge information of the cardiac ultrasound video to evaluate the video quality. The metric was evaluated for its performance in approximating the quality of cardiac ultrasound videos by testing its correlation with the subjective scores of medical experts. The results of our tests showed that the metric has high correlation with medical expert opinions and in several cases outperforms the state-of-the-art video quality metrics considered in our tests. PMID:27014715

  7. The effect of food quality during growth on spatial memory consolidation in adult pigeons.

    PubMed

    Scriba, M F; Gasparini, J; Jacquin, L; Mettke-Hofmann, C; Rattenborg, N C; Roulin, A

    2017-02-15

    Poor environmental conditions experienced during early development can have negative long-term consequences on fitness. Animals can compensate for negative developmental effects through phenotypic plasticity by diverting resources from non-vital to vital traits such as spatial memory to enhance foraging efficiency. We tested in young feral pigeons ( Columba livia ) how diets of different nutritional value during development affect the capacity to retrieve food hidden in a spatially complex environment, a process we refer to as 'spatial memory'. Parents were fed with either high- or low-quality food from egg laying until young fledged, after which all young pigeons received the same high-quality diet until memory performance was tested at 6 months of age. The pigeons were trained to learn a food location out of 18 possible locations in one session, and then their memory of this location was tested 24 h later. Birds reared with the low-quality diet made fewer errors in the memory test. These results demonstrate that food quality during development has long-lasting effects on memory, with a moderate nutritional deficit improving spatial memory performance in a foraging context. It might be that under poor feeding conditions resources are redirected from non-vital to vital traits, or pigeons raised with low-quality food might be better in using environmental cues such as the position of the sun to find where food was hidden. © 2017. Published by The Company of Biologists Ltd.

  8. The use of Minilabs to improve the testing capacity of regulatory authorities in resource limited settings: Tanzanian experience.

    PubMed

    Risha, Peter Gasper; Msuya, Zera; Clark, Malcolm; Johnson, Keith; Ndomondo-Sigonda, Margareth; Layloff, Thomas

    2008-08-01

    The Tanzania Food and Drugs Authority piloted the use of Minilab kits, a thin-layer-chromatographic based drug quality testing technique, in a two-tier quality assurance program. The program is intended to improve testing capacity with timely screening of the quality of medicines as they enter the market. After 1 week training of inspectors on Minilab screening techniques, they were stationed at key Ports-of-Entry (POE) to screen the quality of imported medicines. In addition, three non-Ports-of-Entry centres were established to screen samples collected during Post-Marketing-Surveillance. Standard operating procedures (SOPs) were developed to structure and standardize the implementation process. Over 1200 samples were tested using the Minilab outside the central quality control laboratory (QCL), almost doubling the previous testing capacity. The program contributed to increased regulatory reach and visibility of the Authority throughout the country, serving as a deterrent against entry of substandard medicines into market. The use of Minilab for quality screening was inexpensive and provided a high sample throughput. However, it suffers from the limitation that it can reliably detect only grossly substandard or wrong drug samples and therefore, it should not be used as an independent testing resource but in conjunction with a full-service quality control laboratory capable of auditing reported substandard results.

  9. Quality of life in patients with Parkinson's disease: development of a questionnaire.

    PubMed Central

    de Boer, A G; Wijker, W; Speelman, J D; de Haes, J C

    1996-01-01

    OBJECTIVES--To develop and test a questionnaire for measuring quality of life in patients with Parkinson's disease. METHODS--An item pool was developed based on the experience of patients with Parkinson's disease and of neurologists; medical literature on the problems of patients with Parkinson's disease; and other quality of life questionnaires. To reduce the item pool, 13 patients identified items that were a problem to them and rated their importance. Items which were most often chosen and rated most important were included in the Parkinson's disease quality of life questionnaire (PDQL). The PDQL consists of 37 items. To evaluate the discriminant validity of the PDQL three groups of severity of disease were compared. To test for convergent validity, the scores of the PDQL were tested for correlation with standard indices of quality of life. RESULTS--The PDQL was filled out by 384 patients with Parkinson's disease. It consisted of four subscales: parkinsonian symptoms, systemic symptoms, emotional functioning, and social functioning. The internal-consistency reliability coefficients of the PDQL subscales were high (0.80-0.87). Patients with higher disease severity had significantly lower quality of life on all PDQL subscales (P < 0.05). Almost all PDQL subscales correlated highly (P < 0.001) with the corresponding scales of the standard quality of life indices. CONCLUSION--The PDQL is a relevant, reliable, and valid measure of the quality of life of patients with Parkinson's disease. Images PMID:8676165

  10. Development and flight test results of an autothrottle control system at Mach 3 cruise

    NASA Technical Reports Server (NTRS)

    Gilyard, G. B.; Burken, J. J.

    1980-01-01

    Flight test results obtained with the original Mach hold autopilot designed the YF-12C airplane which uses elevator control and a newly developed Mach hold system having an autothrottle integrated with an altitude hold autopilot system are presented. The autothrottle tests demonstrate good speed control at high Mach numbers and high altitudes while simultaneously maintaining control over altitude and good ride qualities. The autothrottle system was designed to control either Mach number or knots equivalent airspeed (KEAS). Excellent control of Mach number or KEAS was obtained with the autothrottle system when combined with altitude hold. Ride qualities were significantly better than with the conventional Mach hold system.

  11. Effects of dietary quality on basal metabolic rate and internal morphology of European starlings (Sturnus vulgaris)

    USGS Publications Warehouse

    Geluso, Keith; Hayes, J.P.

    1999-01-01

    European starlings (Sturnus vulgaris) were fed either a low- or high-quality diet to test the effects of dietary quality on basal metabolic rate (BMR) and internal morphology. Basal metabolic rate did not differ significantly between the two dietary groups, but internal morphology differed greatly. Starlings fed the low-quality diet had heavier gastrointestinal tracts, gizzards, and livers. Starlings fed the high-quality diet had heavier breast muscles. Starlings on the low-quality diet maintained mass, while starlings on the high-quality diet gained mass. Dry matter digestibility and energy digestibility were lower for starlings fed the low-quality diet, and their food and water intake were greater than starlings on the high-quality diet. The lack of dietary effect on BMR may be the result of increased energy expenditure of digestive organs paralleling a reduction of energy expenditure of organs and tissues not related to digestion (i.e., skeletal muscle). This trade-off in energy allocation among organs suggests a mechanism by which organisms may alter BMR in response to a change in seasonal variation in food availability.

  12. Outcomes Linked to High-Quality Afterschool Programs: Longitudinal Findings from the Study of Promising Afterschool Programs

    ERIC Educational Resources Information Center

    Vandell, Deborah Lowe; Reisner, Elizabeth R.; Pierce, Kim M.

    2007-01-01

    This study by researchers at the University of California, Irvine, the University of Wisconsin-Madison and Policy Studies Associates, Inc. finds that regular participation in high-quality afterschool programs is linked to significant gains in standardized test scores and work habits as well as reductions in behavior problems among disadvantaged…

  13. EPAs DSSTox Chemical Database: A Resource for the Non-Targeted Testing Community (EPA NTA workshop)

    EPA Science Inventory

    EPA’s DSSTox database project, which includes coverage of the ToxCast and Tox21 high-throughput testing inventories, provides high-quality chemical-structure files for inventories of toxicological and environmental relevance. A feature of the DSSTox project, which differentiates ...

  14. [Study on seed quality test and quality standard of Lonicera macranthoides].

    PubMed

    Zhang, Ying; Xu, Jin; Li, Long-Yun; Cui, Guang-Lin; She, Yue-Hui

    2016-04-01

    Referring to the rules for agricultural seed testing (GB/T 3543-1995) issued by China, the test of sampling, purity, thousand seed weight, moisture, viability, relative conductivity and germination rate had been studied for seed quality test methods of Lonicera macranthoides. The seed quality from 38 different collection areas was measured to establish quality classification standard by K-means clustering. The results showed that at least 7.5 g seeds should be sampled, and passed 20-mesh sieve for purity analysis.The 500-seed method used to measure thousand seed weight. The moisture was determined by crushed seeds dried in high temperature (130±2) ℃ for 3 h.The viability determined by 25 ℃ 0.1% TTC stained 5h in dark. 1.0 g seeds soaked in 50 ml ultra pure water in 25 ℃ for 12 hours to determine the relative conductivity. The seed by 4 ℃stratification for 80 days were cultured on paper at 15 ℃. Quality of the seeds from different areas was divided into three grades. The primary seed quality classification standard was established.The I grade and II grade were recommend use in production. Copyright© by the Chinese Pharmaceutical Association.

  15. Restoration of Worn Movable Bridge Props with Use of Bronze Claddings.

    PubMed

    Viňáš, Ján; Vrabeľ, Marek; Greš, Miroslav; Brezina, Jakub; Sabadka, Dušan; Fedorko, Gabriel; Molnár, Vieroslav

    2018-03-21

    This article examined the possibility of using CuSn6P claddings in sliding bearing renovation of movable pontoon bridge props. The bronze layer was welded on cylinders of the high-strength steel S355J0WP EN 10155-93, in an inert atmosphere using an automated welding method (gas tungsten arc welding). Pulsed arc welding was used to minimize the effects of heat on the cladding area, while also accounting for the differences in the physical properties of the joined metals. The sliding bearing was created in two layers. The quality of the cladding layer was evaluated by nondestructive and/or destructive tests. The quality of the surface was assessed by visual inspection (visual testing) in accordance with the EN ISO 17637 standard. The quality of the claddings was evaluated by metallographic analysis, performed using light microscopy. The microhardness values of a few weld areas were determined by Vickers tests, performed according to the EN ISO 9015-2 standard. The analyses confirmed that the welding parameters and filler material used resulted in high-quality weld joints with no internal (subsurface) or metallurgical defects.

  16. Restoration of Worn Movable Bridge Props with Use of Bronze Claddings

    PubMed Central

    Viňáš, Ján; Vrabeľ, Marek; Greš, Miroslav; Brezina, Jakub; Sabadka, Dušan; Fedorko, Gabriel

    2018-01-01

    This article examined the possibility of using CuSn6P claddings in sliding bearing renovation of movable pontoon bridge props. The bronze layer was welded on cylinders of the high-strength steel S355J0WP EN 10155-93, in an inert atmosphere using an automated welding method (gas tungsten arc welding). Pulsed arc welding was used to minimize the effects of heat on the cladding area, while also accounting for the differences in the physical properties of the joined metals. The sliding bearing was created in two layers. The quality of the cladding layer was evaluated by nondestructive and/or destructive tests. The quality of the surface was assessed by visual inspection (visual testing) in accordance with the EN ISO 17637 standard. The quality of the claddings was evaluated by metallographic analysis, performed using light microscopy. The microhardness values of a few weld areas were determined by Vickers tests, performed according to the EN ISO 9015–2 standard. The analyses confirmed that the welding parameters and filler material used resulted in high-quality weld joints with no internal (subsurface) or metallurgical defects. PMID:29561762

  17. Investigation of the effects of bandwidth and time delay on helicopter roll-axis handling qualities

    NASA Technical Reports Server (NTRS)

    Pausder, Heinz-Juergen; Blanken, Chris L.

    1992-01-01

    Several years of cooperative research conducted under the U.S./German Memorandum of Understanding (MOU) in helicopter flight control has recently resulted in a successful handling qualities study. The focus of this cooperative research has been the effects on handling qualities due to time delays in combination with a high bandwidth vehicle. The jointly performed study included the use of U.S. ground-based simulation and German in-flight simulation facilities. The NASA-Ames Vertical Motion Simulator (VMS) was used to develop a high bandwidth slalom tracking task which took into consideration the constraints of the facilities. The VMS was also used to define a range of the test parameters and to perform initial handling qualities evaluations. The flight tests were conducted using DLR's variable-stability BO 105 S3 Advanced Technology Testing Helicopter System (ATTHeS). Configurations included a rate command and an attitude command response system with added time delays up to 160 milliseconds over the baseline and bandwidth values between 1.5 and 4.5 rad/sec. Sixty-six evaluations were performed in about 25 hr of flight time during 10 days of testing. The results indicate a need to more tightly constrain the allowable roll axis phase delay for the Level 1 and Level 2 requirements in the U.S. Army's specification for helicopter handling qualities, ADS-33C.

  18. Investigation of the effects of bandwidth and time delay on helicopter roll-axis handling qualities

    NASA Technical Reports Server (NTRS)

    Blanken, Chris L.; Pausder, Heinz-Jurgen

    1994-01-01

    Several years of cooperative research conducted under the U.S./German Memorandum of Understanding (MOU) in helicopter aeromechanics have recently resulted in a successful handling qualities study. The focus of this cooperative research has been the effect of time delays in a high bandwidth vehicle on handling qualities. The jointly performed study included the use of U.S. ground-based simulation and German in-flight simulation facilities. The NASA-Ames Vertical Motion Simulator (VMS) was used to develop a high bandwidth slalom tracking task which took into consideration the constraints of the facilities. The VMS was used to define a range of the test parameters and to perform initial handling qualities evaluations. The flight tests were conducted using DLR's variable-stability BO 105 S3 Advanced Technology Testing Helicopter System (ATTHeS). Configurations included a rate command and an attitude command response system with added time delays of up to 160 milliseconds over the baseline and band width values between 1.5 and 4.5 rad/sec. Sixty-six evaluations were performed in about 25 hours of flight time during ten days of testing. The results indicate a need to more tightly constrain the allowable roll axis phase delay for the Level 1 and Level 2 requirements in the U.S. Army's specification for helicopter handling qualities Aeronautical Design Standard (ADS)-33C.

  19. Investigation of the effects of bandwidth and time delay on helicopter roll-axis handling qualities

    NASA Technical Reports Server (NTRS)

    Pausder, Heinz-Juergen; Blanken, Chris L.

    1993-01-01

    Several years of cooperative research conducted under the U.S./German Memorandum of Understanding (MOU) in helicopter flight control has recently resulted in a successful handling qualities study. The focus of this cooperative research has been the effects on handling qualities due to time delays in combination with a high bandwidth vehicle. The jointly performed study included the use of U.S. ground-based simulation and German in-flight simulation facilities. The NASA-Ames Vertical Motion Simulator (VMS) was used to develop a high bandwidth slalom tracking task which took into consideration the constraints of the facilities. The VMS was also used to define a range of the test parameters and to perform initial handling qualities evaluations. The flight tests were conducted using DLR's variable-stability BO 105 S3 Advanced Technology Testing Helicopter System (ATTHeS). Configurations included a rate command and an attitude command response system with added time delays up to 160 milliseconds over the baseline and bandwidth values between 1.5 and 4.5 rad/sec. Sixty-six evaluations were performed in about 25 hours of flight time during ten days of testing. The results indicate a need to more tightly constrain the allowable roll axis phase delay for the Level 1 and Level 2 requirements in the U.S. Army's specification for helicopter handling qualities, ADS-33C.

  20. The vaccines consistency approach project: an EPAA initiative.

    PubMed

    De Mattia, F; Hendriksen, C; Buchheit, K H; Chapsal, J M; Halder, M; Lambrigts, D; Redhead, K; Rommel, E; Scharton-Kersten, T; Sesardic, T; Viviani, L; Ragan, I

    2015-01-01

    The consistency approach for release testing of established vaccines promotes the use of in vitro, analytical, non-animal based systems allowing the monitoring of quality parameters during the whole production process. By using highly sensitive non-animal methods, the consistency approach has the potential to improve the quality of testing and to foster the 3Rs (replacement, refinement and reduction of animal use) for quality control of established vaccines. This concept offers an alternative to the current quality control strategy which often requires large numbers of laboratory animals. In order to facilitate the introduction of the consistency approach for established human and veterinary vaccine quality control, the European Partnership for Alternatives to Animal Testing (EPAA) initiated a project, the "Vaccines Consistency Approach Project", aiming at developing and validating the consistency approach with stakeholders from academia, regulators, OMCLs, EDQM, European Commission and industry. This report summarises progress since the project's inception.

  1. Military Personnel: Army Needs to Focus on Cost-Effective Use of Financial Incentives and Quality Standards in Managing Force Growth

    DTIC Science & Technology

    2009-05-01

    diplomas and who score in the upper half on the Armed Forces Qualification Test. The Army implemented some new programs to increase the market of...quality of its enlisted personnel, we analyzed data from OSD on educational credentials and aptitude test scores for these personnel, and we collected...recruits to have high-school diplomas and at least 60 percent to have scores in the upper half on the Armed Forces Qualification Test (AFQT). In fiscal

  2. Quality control tests of lab-reared Cydia pomonella and Cactoblastis cactorum field performance: Comparison of laboratory and field bioassays.

    USDA-ARS?s Scientific Manuscript database

    Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...

  3. [Faecal occult blood test for colorectal cancer screening: high quality for a good price].

    PubMed

    van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J

    2013-01-01

    The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.

  4. Principals' Portfolios: A Reflective Process for Displaying Professional Competencies, Personal Qualities and Job Accomplishments

    ERIC Educational Resources Information Center

    Green, James E.

    2004-01-01

    The current emphasis on high-stakes testing is leaving an unmistakable imprint on all aspects of education. Our curriculum, our instructional methods and materials and even our understanding of the purpose of public education are being reshaped by the standardized tests. Another area where the impact of high-stakes testing can be felt is in the…

  5. Virological diagnosis of Ebolavirus infection.

    PubMed

    Smith, D W; Rawlinson, W D; Kok, J; Dwyer, D E; Catton, M

    2015-08-01

    Ebolaviruses, and the other viral causes of haemorrhagic fevers (VHF) have always posed special problems for diagnostic laboratories. These arise from the rarity of human infections, minimal documented experience with test delivery and interpretation, the paucity of established commercial or in-house assays, the lack of clinical material for test development and validation, the high level containment required for handling live virus, the ongoing evolution of the viruses, and the high personal and public health requirements for accurate diagnosis. This article addresses the current situation and the ongoing challenges associated with delivering timely, high quality and safe testing within Australia for people exposed as part of the current major outbreak of Ebolavirus disease (EVD) in Western Africa. The members of the Public Health Laboratory Network have developed deliverable and reliable nucleic acid detection tests, and also have the laboratory capacity to handle the live viruses if necessary. However delivering and maintaining these services necessitates high levels of experience in developing and applying tests for exotic and emerging infections, strong national and international links and collaborations, ongoing monitoring and reassessment of test design and performance, innovative approaches to generation of positive control material, and a regular quality assurance program.

  6. Virological diagnosis of Ebolavirus infection

    PubMed Central

    Smith, D. W.; Rawlinson, W. D.; Kok, J.; Dwyer, D. E.; Catton, M.

    2015-01-01

    Summary Ebolaviruses, and the other viral causes of haemorrhagic fevers (VHF) have always posed special problems for diagnostic laboratories. These arise from the rarity of human infections, minimal documented experience with test delivery and interpretation, the paucity of established commercial or in-house assays, the lack of clinical material for test development and validation, the high level containment required for handling live virus, the ongoing evolution of the viruses, and the high personal and public health requirements for accurate diagnosis. This article addresses the current situation and the ongoing challenges associated with delivering timely, high quality and safe testing within Australia for people exposed as part of the current major outbreak of Ebolavirus disease (EVD) in Western Africa. The members of the Public Health Laboratory Network have developed deliverable and reliable nucleic acid detection tests, and also have the laboratory capacity to handle the live viruses if necessary. However delivering and maintaining these services necessitates high levels of experience in developing and applying tests for exotic and emerging infections, strong national and international links and collaborations, ongoing monitoring and reassessment of test design and performance, innovative approaches to generation of positive control material, and a regular quality assurance program. PMID:26126050

  7. Very high resolution Earth Observation features for testing the direct and indirect effects of landscape structure on local habitat quality

    NASA Astrophysics Data System (ADS)

    Mairota, Paola; Cafarelli, Barbara; Labadessa, Rocco; Lovergine, Francesco P.; Tarantino, Cristina; Nagendra, Harini; Didham, Raphael K.

    2015-02-01

    Modelling the empirical relationships between habitat quality and species distribution patterns is the first step to understanding human impacts on biodiversity. It is important to build on this understanding to develop a broader conceptual appreciation of the influence of surrounding landscape structure on local habitat quality, across multiple spatial scales. Traditional models which report that 'habitat amount' in the landscape is sufficient to explain patterns of biodiversity, irrespective of habitat configuration or spatial variation in habitat quality at edges, implicitly treat each unit of habitat as interchangeable and ignore the high degree of interdependence between spatial components of land-use change. Here, we test the contrasting hypothesis, that local habitat units are not interchangeable in their habitat attributes, but are instead dependent on variation in surrounding habitat structure at both patch- and landscape levels. As the statistical approaches needed to implement such hierarchical causal models are observation-intensive, we utilise very high resolution (VHR) Earth Observation (EO) images to rapidly generate fine-grained measures of habitat patch internal heterogeneities over large spatial extents. We use linear mixed-effects models to test whether these remotely-sensed proxies for habitat quality were influenced by surrounding patch or landscape structure. The results demonstrate the significant influence of surrounding patch and landscape context on local habitat quality. They further indicate that such an influence can be direct, when a landscape variable alone influences the habitat structure variable, and/or indirect when the landscape and patch attributes have a conjoined effect on the response variable. We conclude that a substantial degree of interaction among spatial configuration effects is likely to be the norm in determining the ecological consequences of habitat fragmentation, thus corroborating the notion of the spatial context dependence of habitat quality.

  8. Development of an advanced pitch active control system for a wide body jet aircraft

    NASA Technical Reports Server (NTRS)

    Guinn, Wiley A.; Rising, Jerry J.; Davis, Walt J.

    1984-01-01

    An advanced PACS control law was developed for a commercial wide-body transport (Lockheed L-1011) by using modern control theory. Validity of the control law was demonstrated by piloted flight simulation tests on the NASA Langley visual motion simulator. The PACS design objective was to develop a PACS that would provide good flying qualities to negative 10 percent static stability margins that were equivalent to those of the baseline aircraft at a 15 percent static stability margin which is normal for the L-1011. Also, the PACS was to compensate for high-Mach/high-g instabilities that degrade flying qualities during upset recoveries and maneuvers. The piloted flight simulation tests showed that the PACS met the design objectives. The simulation demonstrated good flying qualities to negative 20 percent static stability margins for hold, cruise and high-speed flight conditions. Analysis and wind tunnel tests performed on other Lockheed programs indicate that the PACS could be used on an advanced transport configuration to provide a 4 percent fuel savings which results from reduced trim drag by flying at negative static stability margins.

  9. HPLC for quality control of polyimides

    NASA Technical Reports Server (NTRS)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  10. Endorsing good quality assurance practices in molecular pathology: risks and recommendations for diagnostic laboratories and external quality assessment providers.

    PubMed

    Tembuyser, Lien; Dequeker, Elisabeth M C

    2016-01-01

    Quality assurance is an indispensable element in a molecular diagnostic laboratory. The ultimate goal is to warrant patient safety. Several risks that can compromise high quality procedures are at stake, from sample collection to the test performed by the laboratory, the reporting of test results to clinicians, and the organization of effective external quality assessment schemes. Quality assurance should therefore be safeguarded at each level and should imply a holistic multidisciplinary approach. This review aims to provide an overview of good quality assurance practices and discusses certain risks and recommendations to promote and improve quality assurance for both diagnostic laboratories and for external quality assessment providers. The number of molecular targets is continuously rising, and new technologies are evolving. As this poses challenges for clinical implementation and increases the demand for external quality assessment, the formation of an international association for improving quality assurance in molecular pathology is called for.

  11. Patient-reported assessment of quality care at end of life: development and validation of Quality Care Questionnaire-End of Life (QCQ-EOL).

    PubMed

    Yun, Young Ho; Kim, Soo-Hyun; Lee, Kyoung-Min; Park, Sang Min; Lee, Chang Geol; Choi, Youn Seon; Lee, Won Sup; Kim, Si-Young; Heo, Dae Seog

    2006-09-01

    Our goal was to validate an instrument with which terminally ill patients could evaluate the quality of care they receive at the end of life (EOL). Questionnaire development followed a four-phase process: item generation and reduction, construction, pilot testing, and field-testing. Using relevance and priority criteria and pilot testing, we developed a 16-item questionnaire. Factor analyses of data from 235 patients resulted in the Quality Care Questionnaire-End of Life (QCQ-EOL) covering dignity-conserving care, care by health care professionals, individualised care, and family relationships. All subscales and total scores showed high internal consistency (Cronbach alpha range, 0.73-0.89). The ability of total score and selective subscale scores clearly differentiated patients on the basis of clinical situation, sense of dignity, and general rating of care quality. Correlations of scores between patients and caregivers were substantial. The QCQ-EOL can be adopted to assess the quality of care received by terminally ill patients.

  12. Testing Overload in America's Schools

    ERIC Educational Resources Information Center

    Lazarín, Melissa

    2014-01-01

    It appears that schools and families are at a crossroads when it comes to testing. High-quality assessments generate rich data and can provide valuable information about student progress to teachers and parents, support accountability, promote high expectations, and encourage equity for students of color and low-income students. But it is…

  13. 41 CFR 101-25.101-2 - Supply through storage and issue.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dangerous commodities of high weight and density, or commodities highly susceptible to damage normally... close inspection or testing is necessary to secure quality, or where repetitive inspection and test of small lots are prohibitive from the standpoint of cost or potential urgency of need. (3) Where advance...

  14. Responses of aquatic insects to Cu and Zn in stream microcosms: understanding differences between single species tests and field responses.

    PubMed

    Clements, William H; Cadmus, Pete; Brinkman, Stephen F

    2013-07-02

    Field surveys of metal-contaminated streams suggest that some aquatic insects, particularly mayflies (Ephemeroptera) and stoneflies (Plecoptera), are highly sensitive to metals. However, results of single species toxicity tests indicate these organisms are quite tolerant, with LC50 values often several orders of magnitude greater than those obtained using standard test organisms (e.g., cladocerans and fathead minnows). Reconciling these differences is a critical research need, particularly since water quality criteria for metals are based primarily on results of single species toxicity tests. In this research we provide evidence based on community-level microcosm experiments to support the hypothesis that some aquatic insects are highly sensitive to metals. We present results of three experiments that quantified effects of Cu and Zn, alone and in combination, on stream insect communities. EC50 values, defined as the metal concentration that reduced abundance of aquatic insects by 50%, were several orders of magnitude lower than previously published values obtained from single species tests. We hypothesize that the short duration of laboratory toxicity tests and the failure to evaluate effects of metals on sensitive early life stages are the primary factors responsible for unrealistically high LC50 values in the literature. We also observed that Cu alone was significantly more toxic to aquatic insects than the combination of Cu and Zn, despite the fact that exposure concentrations represented theoretically similar toxicity levels. Our results suggest that water quality criteria for Zn were protective of most aquatic insects, whereas Cu was highly toxic to some species at concentrations near water quality criteria. Because of the functional significance of aquatic insects in stream ecosystems and their well-established importance as indicators of water quality, reconciling differences between field and laboratory responses and understanding the mechanisms responsible for variation in sensitivity among metals and metal mixtures is of critical importance.

  15. A systematic review investigating measurement properties of physiological tests in rugby.

    PubMed

    Chiwaridzo, Matthew; Oorschot, Sander; Dambi, Jermaine M; Ferguson, Gillian D; Bonney, Emmanuel; Mudawarima, Tapfuma; Tadyanemhandu, Cathrine; Smits-Engelsman, Bouwien C M

    2017-01-01

    This systematic review was conducted with the first objective aimed at providing an overview of the physiological characteristics commonly evaluated in rugby and the corresponding tests used to measure each construct. Secondly, the measurement properties of all identified tests per physiological construct were evaluated with the ultimate purpose of identifying tests with strongest level of evidence per construct. The review was conducted in two stages. In all stages, electronic databases of EBSCOhost, Medline and Scopus were searched for full-text articles. Stage 1 included studies examining physiological characteristics in rugby. Stage 2 included studies evaluating measurement properties of all tests identified in Stage 1 either in rugby or related sports such as Australian Rules football and Soccer. Two independent reviewers screened relevant articles from titles and abstracts for both stages. Seventy studies met the inclusion criteria for Stage 1. The studies described 63 tests assessing speed (8), agility/change of direction speed (7), upper-body muscular endurance (8), upper-body muscular power (6), upper-body muscular strength (5), anaerobic endurance (4), maximal aerobic power (4), lower-body muscular power (3), prolonged high-intensity intermittent running ability/endurance (5), lower-body muscular strength (5), repeated high-intensity exercise performance (3), repeated-sprint ability (2), repeated-effort ability (1), maximal aerobic speed (1) and abdominal endurance (1). Stage 2 identified 20 studies describing measurement properties of 21 different tests. Only moderate evidence was found for the reliability of the 30-15 Intermittent Fitness. There was limited evidence found for the reliability and/or validity of 5 m, 10 m, 20 m speed tests, 505 test, modified 505 test, L run test, Sergeant Jump test and bench press repetitions-to-fatigue tests. There was no information from high-quality studies on the measurement properties of all the other tests identified in stage 1. A number of physiological characteristics are evaluated in rugby. Each physiological construct has multiple tests for measurement. However, there is paucity of information on measurement properties from high-quality studies for the tests. This raises questions about the usefulness and applicability of these tests in rugby and creates a need for high-quality future studies evaluating measurement properties of these physiological tests. PROSPERO CRD 42015029747.

  16. 75 FR 24892 - Certain Coated Paper Suitable for High-Quality Print Graphics Using Sheet-Fed Presses From the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ... Industry Support Calculation Coated Paper Suitable For High-Quality Print Graphics Using Sheet-Fed Presses... employs an industry-wide test to determine whether, under section 773(c)(1)(B), available information in... sections 771(33)(E) and (F) of the Act. In addition, we find that Shandong Sun Paper Industry Joint Stock...

  17. Indoor Air Quality in 24 California Residences Designed as High-Performance Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Less, Brennan; Mullen, Nasim; Singer, Brett

    2015-07-01

    Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California.

  18. Evaluation of the quality of life of patients with diabetes mellitus treated with conventional or analogue insulins.

    PubMed

    Machado-Alba, Jorge Enrique; Medina-Morales, Diego Alejandro; Echeverri-Cataño, Luis Felipe

    2016-06-01

    The results of two scales that measure quality of life of patients with diabetes mellitus treated with conventional or analogue insulin were evaluated and compared. Descriptive, observational, cross-sectional study, conducted in the cities of Pereira and Manizales, Colombia, in a care facility between 1 August 2013 and 30 March 2014. A total of 238 patients diagnosed with diabetes mellitus type 1 or type 2 who had been undergoing treatment with conventional or analogue insulin for at least 6months. Comparison of the results of the Diabetes 39 (specific) and European Quality of Life-5 Dimensions (EQ-5D) (generic) tools it was performed. Comparisons between the results of the two instruments were performed. Tests for parametric and non-parametric distribution (Pearson's correlation coefficient, Mann-Whitney U test, Student's t-test and Wilcoxon test) were used. The mean age was 57.7±16.6years. Conventional insulin was prescribed to 69.6% of patients, and analogue insulin was prescribed to 30.4% of patients. Diabetes-39 (D-39) showed 24.7% of subjects with a high quality of life. No statistically significant differences were found when comparing patients prescribed conventional or analogue insulin (p=0.35; 95% confidence interval [CI]: 0.375-1.419). In the EQ-5D survey, 45.7% claimed to have a high quality of life, without statistically significant differences between groups (p=0.56; 95%CI: 0.676-2.047). No differences between patients receiving conventional insulin versus analogue insulin were detected in terms of quality of life. The group aged over 60years requires special attention to improve their quality of life, and programs should focus on those individuals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Flight Measurements of the Flying Qualities of a Lockheed P-80A Airplane (Army No. 44-85099): Lateral- and Directional-Stability and Control Characteristics

    NASA Technical Reports Server (NTRS)

    Anderson, Seth B.; Cooper, George E.

    1947-01-01

    This report contains the flight-test results of the lateral and directional-stability and control phase (including tests with wing-tip tanks) of a general flying-qualities investigation of the Lockheed P-80A airplane (Army No. 44-85099). These tests were conducted at indicated airspeeds up to 494 miles per hour (0.691 Mach number) at low altitude and up to 378 miles per hour (0.816 Mach number) at high altitude. These tests showed that the flying qualities of the airplane were for the most part in accordance with the requirements of the Army Air Forces Stability and Control Specifications. The only major deficiency noted was the negative lateral stability with the wing-tip tanks installed.

  20. Influence of raw milk quality on processed dairy products: How do raw milk quality test results relate to product quality and yield?

    PubMed

    Murphy, Steven C; Martin, Nicole H; Barbano, David M; Wiedmann, Martin

    2016-12-01

    This article provides an overview of the influence of raw milk quality on the quality of processed dairy products and offers a perspective on the merits of investing in quality. Dairy farmers are frequently offered monetary premium incentives to provide high-quality milk to processors. These incentives are most often based on raw milk somatic cell and bacteria count levels well below the regulatory public health-based limits. Justification for these incentive payments can be based on improved processed product quality and manufacturing efficiencies that provide the processor with a return on their investment for high-quality raw milk. In some cases, this return on investment is difficult to measure. Raw milks with high levels of somatic cells and bacteria are associated with increased enzyme activity that can result in product defects. Use of raw milk with somatic cell counts >100,000cells/mL has been shown to reduce cheese yields, and higher levels, generally >400,000 cells/mL, have been associated with textural and flavor defects in cheese and other products. Although most research indicates that fairly high total bacteria counts (>1,000,000 cfu/mL) in raw milk are needed to cause defects in most processed dairy products, receiving high-quality milk from the farm allows some flexibility for handling raw milk, which can increase efficiencies and reduce the risk of raw milk reaching bacterial levels of concern. Monitoring total bacterial numbers in regard to raw milk quality is imperative, but determining levels of specific types of bacteria present has gained increasing importance. For example, spores of certain spore-forming bacteria present in raw milk at very low levels (e.g., <1/mL) can survive pasteurization and grow in milk and cheese products to levels that result in defects. With the exception of meeting product specifications often required for milk powders, testing for specific spore-forming groups is currently not used in quality incentive programs in the United States but is used in other countries (e.g., the Netherlands). Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Development and pilot of an internationally standardized measure of cardiovascular risk management in European primary care

    PubMed Central

    2011-01-01

    Background Primary care can play an important role in providing cardiovascular risk management in patients with established Cardiovascular Diseases (CVD), patients with a known high risk of developing CVD, and potentially for individuals with a low risk of developing CVD, but who have unhealthy lifestyles. To describe and compare cardiovascular risk management, internationally valid quality indicators and standardized measures are needed. As part of a large project in 9 European countries (EPA-Cardio), we have developed and tested a set of standardized measures, linked to previously developed quality indicators. Methods A structured stepwise procedure was followed to develop measures. First, the research team allocated 106 validated quality indicators to one of the three target populations (established CVD, at high risk, at low risk) and to different data-collection methods (data abstraction from the medical records, a patient survey, an interview with lead practice GP/a practice survey). Secondly, we selected a number of other validated measures to enrich the assessment. A pilot study was performed to test the feasibility. Finally, we revised the measures based on the findings. Results The EPA-Cardio measures consisted of abstraction forms from the medical-records data of established Coronary Heart Disease (CHD)-patients - and high-risk groups, a patient questionnaire for each of the 3 groups, an interview questionnaire for the lead GP and a questionnaire for practice teams. The measures were feasible and accepted by general practices from different countries. Conclusions An internationally standardized measure of cardiovascular risk management, linked to validated quality indicators and tested for feasibility in general practice, is now available. Careful development and pilot testing of the measures are crucial in international studies of quality of healthcare. PMID:21473758

  2. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    PubMed

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Some Problems of Computer-Aided Testing and "Interview-Like Tests"

    ERIC Educational Resources Information Center

    Smoline, D.V.

    2008-01-01

    Computer-based testing--is an effective teacher's tool, intended to optimize course goals and assessment techniques in a comparatively short time. However, this is accomplished only if we deal with high-quality tests. It is strange, but despite the 100-year history of Testing Theory (see, Anastasi, A., Urbina, S. (1997). Psychological testing.…

  4. Test-Wiseness Cues in the Options of Mathematics Items.

    ERIC Educational Resources Information Center

    Kuntz, Patricia

    The quality of mathematics multiple choice items and their susceptibility to test wiseness were examined. Test wiseness was defined as "a subject's capacity to utilize the characteristics and formats of the test and/or test taking situation to receive a high score." The study used results of the Graduate Record Examinations Aptitude Test (GRE) and…

  5. Continuous Quality Improvement: A Roadmap for Rural School Improvement.

    ERIC Educational Resources Information Center

    Kilmer, Lloyd C.

    A case study documented a continuous quality improvement approach to school improvement in a rural Nebraska high school over a 2-year period. Data gathered from surveys, portfolios, pilot results, and test scores indicated that the changes during the 2-year period were not dramatic, but significant and consistent with the Total Quality literature.…

  6. Children's Eye-Movements during Reading Reflect the Quality of Lexical Representations: An Individual Differences Approach

    ERIC Educational Resources Information Center

    Luke, Steven G.; Henderson, John M.; Ferreira, Fernanda

    2015-01-01

    The lexical quality hypothesis (Perfetti & Hart, 2002) suggests that skilled reading requires high-quality lexical representations. In children, these representations are still developing, and it has been suggested that this development leads to more adult-like eye-movement behavior during the reading of connected text. To test this idea, a…

  7. Improving medication adherence among community-dwelling seniors with cognitive impairment: a systematic review of interventions.

    PubMed

    Kröger, Edeltraut; Tatar, Ovidiu; Vedel, Isabelle; Giguère, Anik M C; Voyer, Philippe; Guillaumie, Laurence; Grégoire, Jean-Pierre; Guénette, Line

    2017-08-01

    Background Medication non-adherence may lead to poor therapeutic outcomes. Cognitive functions deteriorate with age, contributing to decreased adherence. Interventions have been tested to improve adherence in seniors with cognitive impairment or Alzheimer disease (AD), but high-quality systematic reviews are lacking. It remains unclear which interventions are promising. Objectives We conducted a systematic review to identify, describe, and evaluate interventions aimed at improving medication adherence among seniors with any type of cognitive impairment. Methods Following NICE guidance, databases and websites were searched using combinations of controlled and free vocabulary. All adherence-enhancing interventions and study designs were considered. Studies had to include community dwelling seniors, aged 65 years or older, with cognitive impairment, receiving at least one medication for a chronic condition, and an adherence measure. Study characteristics and methodological quality were assessed. Results We identified 13 interventions, including six RCTs. Two studies were of poor, nine of low/medium and two of high quality. Seven studies had sample sizes below 50 and six interventions focused on adherence to AD medication. Six interventions tested a behavioral, four a medication oriented, two an educational and one a multi-faceted approach. Studies rarely assessed therapeutic outcomes. All but one intervention showed improved adherence. Conclusion Three medium quality studies showed better adherence with patches than with pills for AD treatment. Promising interventions used educational or reminding strategies, including one high quality RCT. Nine studies were of low/moderate quality. High quality RCTs using a theoretical framework for intervention selection are needed to identify strategies for improved adherence in these seniors.

  8. Speech perception and quality of life of open-fit hearing aid users

    PubMed Central

    GARCIA, Tatiana Manfrini; JACOB, Regina Tangerino de Souza; MONDELLI, Maria Fernanda Capoani Garcia

    2016-01-01

    ABSTRACT Objective To relate the performance of individuals with hearing loss at high frequencies in speech perception with the quality of life before and after the fitting of an open-fit hearing aid (HA). Methods The WHOQOL-BREF had been used before the fitting and 90 days after the use of HA. The Hearing in Noise Test (HINT) had been conducted in two phases: (1) at the time of fitting without an HA (situation A) and with an HA (situation B); (2) with an HA 90 days after fitting (situation C). Study Sample Thirty subjects with sensorineural hearing loss at high frequencies. Results By using an analysis of variance and the Tukey’s test comparing the three HINT situations in quiet and noisy environments, an improvement has been observed after the HA fitting. The results of the WHOQOL-BREF have showed an improvement in the quality of life after the HA fitting (paired t-test). The relationship between speech perception and quality of life before the HA fitting indicated a significant relationship between speech recognition in noisy environments and in the domain of social relations after the HA fitting (Pearson’s correlation coefficient). Conclusions The auditory stimulation has improved speech perception and the quality of life of individuals. PMID:27383708

  9. UTILIZATION OF TREATABILITY AND PILOT TESTS TO PREDICT CAH BIOREMEDIATION

    EPA Science Inventory

    Multiple tools have been suggested to help in the design of enhanced anaerobic bioremediation systems for CAHs:
    - Extensive high quality microcosm testing followed by small-scale, thoroughly observed field pilot tests (i.e., RABITT Protocol, Morse 1998)
    - More limited ...

  10. Economic Evaluations of Pathology Tests, 2010-2015: A Scoping Review.

    PubMed

    Watts, Rory D; Li, Ian W; Geelhoed, Elizabeth A; Sanfilippo, Frank M; St John, Andrew

    2017-09-01

    Concerns about pathology testing such as the value provided by new tests and the potential for inappropriate utilization have led to a greater need to assess costs and benefits. Economic evaluations are a formal method of analyzing costs and benefits, yet for pathology tests, questions remain about the scope and quality of the economic evidence. To describe the extent and quality of published evidence provided by economic evaluations of pathology tests from 2010 to 2015. Economic evaluations relating to pathology tests from 2010 to 2015 were reviewed. Eight databases were searched for published studies, and details recorded for the country, clinical focus, type of testing, and consideration of sensitivity, specificity, and false test results. The reporting quality of studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards checklist and cost-effectiveness ratios were analyzed for publication bias. We found 356 economic evaluations of pathology tests, most of which regarded developed countries. The most common economic evaluations were cost-utility analyses and the most common clinical focus was infectious diseases. More than half of the studies considered sensitivity and specificity, but few studies considered the impact of false test results. The average Consolidated Health Economic Evaluation Reporting Standards checklist score was 17 out of 24. Cost-utility ratios were commonly less than $10,000/quality-adjusted life-year or more than $200,000/quality-adjusted life-year. The number of economic evaluations of pathology tests has increased in recent years, but the rate of increase has plateaued. Furthermore, the quality of studies in the past 5 years was highly variable, and there is some question of publication bias in reporting cost-effectiveness ratios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  11. Local environmental quality positively predicts breastfeeding in the UK’s Millennium Cohort Study

    PubMed Central

    Sear, Rebecca

    2017-01-01

    ABSTRACT Background and Objectives: Breastfeeding is an important form of parental investment with clear health benefits. Despite this, rates remain low in the UK; understanding variation can therefore help improve interventions. Life history theory suggests that environmental quality may pattern maternal investment, including breastfeeding. We analyse a nationally representative dataset to test two predictions: (i) higher local environmental quality predicts higher likelihood of breastfeeding initiation and longer duration; (ii) higher socioeconomic status (SES) provides a buffer against the adverse influences of low local environmental quality. Methodology: We ran factor analysis on a wide range of local-level environmental variables. Two summary measures of local environmental quality were generated by this analysis—one ‘objective’ (based on an independent assessor’s neighbourhood scores) and one ‘subjective’ (based on respondent’s scores). We used mixed-effects regression techniques to test our hypotheses. Results: Higher objective, but not subjective, local environmental quality predicts higher likelihood of starting and maintaining breastfeeding over and above individual SES and area-level measures of environmental quality. Higher individual SES is protective, with women from high-income households having relatively high breastfeeding initiation rates and those with high status jobs being more likely to maintain breastfeeding, even in poor environmental conditions. Conclusions and Implications: Environmental quality is often vaguely measured; here we present a thorough investigation of environmental quality at the local level, controlling for individual- and area-level measures. Our findings support a shift in focus away from individual factors and towards altering the landscape of women’s decision making contexts when considering behaviours relevant to public health. PMID:29354262

  12. Local environmental quality positively predicts breastfeeding in the UK's Millennium Cohort Study.

    PubMed

    Brown, Laura J; Sear, Rebecca

    2017-01-01

    Background and Objectives: Breastfeeding is an important form of parental investment with clear health benefits. Despite this, rates remain low in the UK; understanding variation can therefore help improve interventions. Life history theory suggests that environmental quality may pattern maternal investment, including breastfeeding. We analyse a nationally representative dataset to test two predictions: (i) higher local environmental quality predicts higher likelihood of breastfeeding initiation and longer duration; (ii) higher socioeconomic status (SES) provides a buffer against the adverse influences of low local environmental quality. Methodology: We ran factor analysis on a wide range of local-level environmental variables. Two summary measures of local environmental quality were generated by this analysis-one 'objective' (based on an independent assessor's neighbourhood scores) and one 'subjective' (based on respondent's scores). We used mixed-effects regression techniques to test our hypotheses. Results: Higher objective, but not subjective, local environmental quality predicts higher likelihood of starting and maintaining breastfeeding over and above individual SES and area-level measures of environmental quality. Higher individual SES is protective, with women from high-income households having relatively high breastfeeding initiation rates and those with high status jobs being more likely to maintain breastfeeding, even in poor environmental conditions. Conclusions and Implications: Environmental quality is often vaguely measured; here we present a thorough investigation of environmental quality at the local level, controlling for individual- and area-level measures. Our findings support a shift in focus away from individual factors and towards altering the landscape of women's decision making contexts when considering behaviours relevant to public health.

  13. An Exploratory Investigation of the Role of Openness in Relationship Quality among Emerging Adult Chinese Couples

    PubMed Central

    Zhou, Yixin; Wang, Kexin; Chen, Shuang; Zhang, Jianxin; Zhou, Mingjie

    2017-01-01

    This study tested emerging adult couples’ openness and its fit effect on their romantic relationship quality using quadratic polynomial regression and response surface analysis. Participants were 260 emerging adult dyads. Both dyads’ openness and relationship quality were measured. The result showed that (1) female and male openness contribute differently to relationship quality; (2) couples with similar high openness could experience better relationship quality than those with similar low openness traits; and (3) when dyadic openness is dissimilar, it is better to be either relatively high or relatively low than to be moderate. These findings highlight the role of openness in emerging adults’ romantic relationships from a dyadic angle. PMID:28360875

  14. Development and validation of a tool to evaluate the quality of medical education websites in pathology.

    PubMed

    Alyusuf, Raja H; Prasad, Kameshwar; Abdel Satir, Ali M; Abalkhail, Ali A; Arora, Roopa K

    2013-01-01

    The exponential use of the internet as a learning resource coupled with varied quality of many websites, lead to a need to identify suitable websites for teaching purposes. The aim of this study is to develop and to validate a tool, which evaluates the quality of undergraduate medical educational websites; and apply it to the field of pathology. A tool was devised through several steps of item generation, reduction, weightage, pilot testing, post-pilot modification of the tool and validating the tool. Tool validation included measurement of inter-observer reliability; and generation of criterion related, construct related and content related validity. The validated tool was subsequently tested by applying it to a population of pathology websites. Reliability testing showed a high internal consistency reliability (Cronbach's alpha = 0.92), high inter-observer reliability (Pearson's correlation r = 0.88), intraclass correlation coefficient = 0.85 and κ =0.75. It showed high criterion related, construct related and content related validity. The tool showed moderately high concordance with the gold standard (κ =0.61); 92.2% sensitivity, 67.8% specificity, 75.6% positive predictive value and 88.9% negative predictive value. The validated tool was applied to 278 websites; 29.9% were rated as recommended, 41.0% as recommended with caution and 29.1% as not recommended. A systematic tool was devised to evaluate the quality of websites for medical educational purposes. The tool was shown to yield reliable and valid inferences through its application to pathology websites.

  15. Measuring Reciprocity in High Functioning Children and Adolescents with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    van Ommeren, Tineke Backer; Begeer, Sander; Scheeren, Anke M.; Koot, Hans M.

    2012-01-01

    Few instruments have been developed that measure impairments in reciprocity, a defining feature of autism. We introduce a new test assessing the quality of reciprocal behaviour: the interactive drawing test (IDT). Children and adolescents (n = 49) with and without high functioning autism spectrum disorders (HFASD) were invited to collaborate with…

  16. High dynamic range subjective testing

    NASA Astrophysics Data System (ADS)

    Allan, Brahim; Nilsson, Mike

    2016-09-01

    This paper describes of a set of subjective tests that the authors have carried out to assess the end user perception of video encoded with High Dynamic Range technology when viewed in a typical home environment. Viewers scored individual single clips of content, presented in High Definition (HD) and Ultra High Definition (UHD), in Standard Dynamic Range (SDR), and in High Dynamic Range (HDR) using both the Perceptual Quantizer (PQ) and Hybrid Log Gamma (HLG) transfer characteristics, and presented in SDR as the backwards compatible rendering of the HLG representation. The quality of SDR HD was improved by approximately equal amounts by either increasing the dynamic range or increasing the resolution to UHD. A further smaller increase in quality was observed in the Mean Opinion Scores of the viewers by increasing both the dynamic range and the resolution, but this was not quite statistically significant.

  17. Use of Terrestrial Laser Scanning Technology for Long Term High Precision Deformation Monitoring

    PubMed Central

    Vezočnik, Rok; Ambrožič, Tomaž; Sterle, Oskar; Bilban, Gregor; Pfeifer, Norbert; Stopar, Bojan

    2009-01-01

    The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable. PMID:22303152

  18. Physical examination tests for screening and diagnosis of cervicogenic headache: A systematic review.

    PubMed

    Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E

    2016-02-01

    It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Perception of synthetic speech produced automatically by rule: Intelligibility of eight text-to-speech systems.

    PubMed

    Greene, Beth G; Logan, John S; Pisoni, David B

    1986-03-01

    We present the results of studies designed to measure the segmental intelligibility of eight text-to-speech systems and a natural speech control, using the Modified Rhyme Test (MRT). Results indicated that the voices tested could be grouped into four categories: natural speech, high-quality synthetic speech, moderate-quality synthetic speech, and low-quality synthetic speech. The overall performance of the best synthesis system, DECtalk-Paul, was equivalent to natural speech only in terms of performance on initial consonants. The findings are discussed in terms of recent work investigating the perception of synthetic speech under more severe conditions. Suggestions for future research on improving the quality of synthetic speech are also considered.

  20. Critical Directed Energy Test and Evaluation Infrastructure Shortfalls: Results of the Directed Energy Test and Evaluation Capability Tri-Service Study Update

    DTIC Science & Technology

    2009-06-01

    Sensor H11 HPM Chamber Test Capability—Explosive Equivalent Substitute H12 HEL Irradiance & Temperature H13 HEL Near/In-Beam Path Quality H14 HPM Sensor...such things as artillery shells or UAVs and may impact the earth. Possible targets include missiles in flight or a relatively close command, control...capability is a synergy of four high priority shortfalls identified by the T-SS Update. H13 —HEL near/in-beam path quality H13 is the need for a

  1. The Effects of Argument Quality and Involvement Type on Attitude Formation and Attitude Change: A Test of Dual-Process and Social Judgment Predictions

    ERIC Educational Resources Information Center

    Park, Hee Sun; Levine, Timothy R.; Kingsley Westerman, Catherine Y.; Orfgen, Tierney; Foregger, Sarah

    2007-01-01

    Involvement has long been theoretically specified as a crucial factor determining the persuasive impact of messages. In social judgment theory, ego-involvement makes people more resistant to persuasion, whereas in dual-process models, high-involvement people are susceptible to persuasion when argument quality is high. It is argued that these…

  2. Water quality monitoring for high-priority water bodies in the Sonoran Desert network

    Treesearch

    Terry W. Sprouse; Robert M. Emanuel; Sara A. Strorrer

    2005-01-01

    This paper describes a network monitoring program for “high priority” water bodies in the Sonoran Desert Network of the National Park Service. Protocols were developed for monitoring selected waters for ten of the eleven parks in the Network. Park and network staff assisted in identifying potential locations of testing sites, local priorities, and how water quality...

  3. The Architecture Design of Detection and Calibration System for High-voltage Electrical Equipment

    NASA Astrophysics Data System (ADS)

    Ma, Y.; Lin, Y.; Yang, Y.; Gu, Ch; Yang, F.; Zou, L. D.

    2018-01-01

    With the construction of Material Quality Inspection Center of Shandong electric power company, Electric Power Research Institute takes on more jobs on quality analysis and laboratory calibration for high-voltage electrical equipment, and informationization construction becomes urgent. In the paper we design a consolidated system, which implements the electronic management and online automation process for material sampling, test apparatus detection and field test. In the three jobs we use QR code scanning, online Word editing and electronic signature. These techniques simplify the complex process of warehouse management and testing report transferring, and largely reduce the manual procedure. The construction of the standardized detection information platform realizes the integrated management of high-voltage electrical equipment from their networking, running to periodic detection. According to system operation evaluation, the speed of transferring report is doubled, and querying data is also easier and faster.

  4. Environmental education curriculum evaluation questionnaire: A reliability and validity study

    NASA Astrophysics Data System (ADS)

    Minner, Daphne Diane

    The intention of this research project was to bridge the gap between social science research and application to the environmental domain through the development of a theoretically derived instrument designed to give educators a template by which to evaluate environmental education curricula. The theoretical base for instrument development was provided by several developmental theories such as Piaget's theory of cognitive development, Developmental Systems Theory, Life-span Perspective, as well as curriculum research within the area of environmental education. This theoretical base fueled the generation of a list of components which were then translated into a questionnaire with specific questions relevant to the environmental education domain. The specific research question for this project is: Can a valid assessment instrument based largely on human development and education theory be developed that reliably discriminates high, moderate, and low quality in environmental education curricula? The types of analyses conducted to answer this question were interrater reliability (percent agreement, Cohen's Kappa coefficient, Pearson's Product-Moment correlation coefficient), test-retest reliability (percent agreement, correlation), and criterion-related validity (correlation). Face validity and content validity were also assessed through thorough reviews. Overall results indicate that 29% of the questions on the questionnaire demonstrated a high level of interrater reliability and 43% of the questions demonstrated a moderate level of interrater reliability. Seventy-one percent of the questions demonstrated a high test-retest reliability and 5% a moderate level. Fifty-five percent of the questions on the questionnaire were reliable (high or moderate) both across time and raters. Only eight questions (8%) did not show either interrater or test-retest reliability. The global overall rating of high, medium, or low quality was reliable across both coders and time, indicating that the questionnaire can discriminate differences in quality of environmental education curricula. Of the 35 curricula evaluated, 6 were high quality, 14 were medium quality and 15 were low quality. The criterion-related validity of the instrument is at current time unable to be established due to the lack of comparable measures or a concretely usable set of multidisciplinary standards. Face and content validity were sufficiently demonstrated.

  5. UTILIZATION OF TREATABILITY AND PILOT TESTS TO PREDICT CAH BIOREMEDIATION (Battelle)

    EPA Science Inventory

    Multiple tools have been suggested to help in the design of enhanced anaerobic bioremediation systems for CAHs:
    Extensive high quality microcosm testing followed by small-scale, thoroughly observed, induced flow field pilot tests (i.e. RABITT Protocol, Morse 1998)
    More...

  6. SMART-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hodge, Bri-Mathias; Palmintier, Bryan

    This presentation provides an overview of full-scale, high-quality, synthetic distribution system data set(s) for testing distribution automation algorithms, distributed control approaches, ADMS capabilities, and other emerging distribution technologies.

  7. NWTC Engineer Wins Prestigious International Electrotechnical Commission

    Science.gov Websites

    IEC TC88, the technical committee responsible for writing the international standards for wind energy levels of safety and by defining test methods that provide high-quality, reproducible test results."

  8. 24th geotechnical laboratory testing short course

    DOT National Transportation Integrated Search

    2008-02-01

    This is a 3-day workshop/short course to teach practicing professionals techniques and procedures for conducting high quality geotechnical laboratory tests. Transportation facility design and construction begins with an investigation of the type, ext...

  9. Using Tablet PC's for the Final Test of Baccalaureate

    ERIC Educational Resources Information Center

    Laborda, Jesús García; Royo, Teresa Magal

    2016-01-01

    Online testing is becoming a popular way to deliver language tests, partly because of its reduced cost, partly because of the high quality of test data collection. In language tests, interface validation has received a limited attention in professional literature (García, Magal, da Rocha, & Fernández, 2010). This paper will show the validation…

  10. System reliability analysis through corona testing

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.

    1975-01-01

    A corona vacuum test facility for nondestructive testing of power system components was built in the Reliability and Quality Engineering Test Laboratories at the NASA Lewis Research Center. The facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. The facility is being used to test various high-voltage power system components.

  11. A Process for Reviewing and Evaluating Generated Test Items

    ERIC Educational Resources Information Center

    Gierl, Mark J.; Lai, Hollis

    2016-01-01

    Testing organization needs large numbers of high-quality items due to the proliferation of alternative test administration methods and modern test designs. But the current demand for items far exceeds the supply. Test items, as they are currently written, evoke a process that is both time-consuming and expensive because each item is written,…

  12. Image Quality Assessment of High-Resolution Satellite Images with Mtf-Based Fuzzy Comprehensive Evaluation Method

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Luo, Z.; Zhang, Y.; Guo, F.; He, L.

    2018-04-01

    A Modulation Transfer Function (MTF)-based fuzzy comprehensive evaluation method was proposed in this paper for the purpose of evaluating high-resolution satellite image quality. To establish the factor set, two MTF features and seven radiant features were extracted from the knife-edge region of image patch, which included Nyquist, MTF0.5, entropy, peak signal to noise ratio (PSNR), average difference, edge intensity, average gradient, contrast and ground spatial distance (GSD). After analyzing the statistical distribution of above features, a fuzzy evaluation threshold table and fuzzy evaluation membership functions was established. The experiments for comprehensive quality assessment of different natural and artificial objects was done with GF2 image patches. The results showed that the calibration field image has the highest quality scores. The water image has closest image quality to the calibration field, quality of building image is a little poor than water image, but much higher than farmland image. In order to test the influence of different features on quality evaluation, the experiment with different weights were tested on GF2 and SPOT7 images. The results showed that different weights correspond different evaluating effectiveness. In the case of setting up the weights of edge features and GSD, the image quality of GF2 is better than SPOT7. However, when setting MTF and PSNR as main factor, the image quality of SPOT7 is better than GF2.

  13. Centers for medicare and medicaid services: using an episode-based payment model to improve oncology care.

    PubMed

    Kline, Ronald M; Bazell, Carol; Smith, Erin; Schumacher, Heidi; Rajkumar, Rahul; Conway, Patrick H

    2015-03-01

    Cancer is a medically complex and expensive disease with costs projected to rise further as new treatment options increase and the United States population ages. Studies showing significant regional variation in oncology quality and costs and model tests demonstrating cost savings without adverse outcomes suggest there are opportunities to create a system of oncology care in the US that delivers higher quality care at lower cost. The Centers for Medicare and Medicaid Services (CMS) have designed an episode-based payment model centered around 6 month periods of chemotherapy treatment. Monthly per-patient care management payments will be made to practices to support practice transformation, including additional patient services and specific infrastructure enhancements. Quarterly reporting of quality metrics will drive continuous quality improvement and the adoption of best practices among participants. Practices achieving cost savings will also be eligible for performance-based payments. Savings are expected through improved care coordination and appropriately aligned payment incentives, resulting in decreased avoidable emergency department visits and hospitalizations and more efficient and evidence-based use of imaging, laboratory tests, and therapeutic agents, as well as improved end of life care. New therapies and better supportive care have significantly improved cancer survival in recent decades. This has come at a high cost, with cancer therapy consuming $124 billion in 2010. CMS has designed an episode-based model of oncology care that incorporates elements from several successful model tests. By providing care management and performance based payments in conjunction with quality metrics and a rapid learning environment, it is hoped that this model will demonstrate how oncology care in the US can transform into a high value, high quality system. Copyright © 2015 by American Society of Clinical Oncology.

  14. System reliability analysis through corona testing

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.

    1975-01-01

    In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.

  15. Double-quality control reveals high-level toxicity in gloves used for operator protection in assisted reproductive technology.

    PubMed

    Lierman, Sylvie; De Sutter, Petra; Dhont, Marc; Van der Elst, Josiane

    2007-10-01

    To submit different glove brands to double-quality control tests using mouse embryo assay (MEA) and the human sperm motility assay (HuSMA). Operator protection against infectious body fluid contamination is a safety issue in assisted reproductive technology (ART). When using gloves in the ART laboratory, toxic substances can be transmitted to culture media, even during brief contact. Quality control study of gloves in ART. University hospital-based infertility center. Seven- to 8-week-old female B6D2F1 hybrid mice. We tested two surgical, two cleanroom, and six examination glove brands. Only gloves brands that passed both HuSMA and MEA were submitted to further QC using zona-free and/or cryopreserved MEA. Sperm motility index, two-cell and blastocyst development, blastocyst total cell number. Quality control by MEA and HuSMA identified two glove brands to be nontoxic. Our study shows that gloves used in ART can be toxic and should be tested as part of an ongoing quality control program.

  16. Intermediate quality control tests in the development of a superconducting RF cryomodule for CW operation

    NASA Astrophysics Data System (ADS)

    Pattalwar, Shrikant; Jones, Thomas; Strachan, John; Bate, Robert; Davies, Phil; McIntosh, Peter

    2012-06-01

    Through an international cryomodule collaboration, ASTeC at Daresbury Laboratory has taken the primary responsibility in leading the development of an optimised Superconducting RF (SRF) cryomodule, operating in CW mode for energy recovery facilities and other high duty cycle accelerators. For high beam current operation, Higher Order Mode (HOM) absorbers are critical components of the SRF Cryomodule, ensuring excessive heating of the accelerating structures and beam instabilities are effectively managed. This paper describes some of the cold tests conducted on the HOM absorbers and other critical components during the construction phase, to ensure that the quality and reliable cryomodule performance is maintained.

  17. Gluten-Free Precooked Rice-Yellow Pea Pasta: Effect of Extrusion-Cooking Conditions on Phenolic Acids Composition, Selected Properties and Microstructure.

    PubMed

    Bouasla, Abdallah; Wójtowicz, Agnieszka; Zidoune, Mohammed Nasereddine; Olech, Marta; Nowak, Renata; Mitrus, Marcin; Oniszczuk, Anna

    2016-05-01

    Rice/yellow pea flour blend (2/1 ratio) was used to produce gluten-free precooked pasta using a single-screw modified extrusion-cooker TS-45. The effect of moisture content (28%, 30%, and 32%) and screw speed (60, 80, and 100 rpm) on some quality parameters was assessed. The phenolic acids profile and selected pasta properties were tested, like pasting properties, water absorption capacity, cooking loss, texture characteristics, microstructure, and sensory overall acceptability. Results indicated that dough moisture content influenced all tested quality parameters of precooked pasta except firmness. Screw speed showed an effect only on some quality parameters. The extrusion-cooking process at 30% of dough moisture with 80 rpm is appropriate to obtain rice-yellow pea precooked pasta with high content of phenolics and adequate quality. These pasta products exhibited firm texture, low stickiness, and regular and compact interne structure confirmed by high score in sensory overall acceptability. © 2016 Institute of Food Technologists®

  18. LANDSAT-4 MSS and Thematic Mapper data quality and information content analysis

    NASA Technical Reports Server (NTRS)

    Anuta, P.; Bartolucci, L.; Dean, E.; Lozano, F.; Malaret, E.; Mcgillem, C. D.; Valdes, J.; Valenzuela, C.

    1984-01-01

    LANDSAT-4 thematic mapper (TM) and multispectral scanner (MSS) data were analyzed to obtain information on data quality and information content. Geometric evaluations were performed to test band-to-band registration accuracy. Thematic mapper overall system resolution was evaluated using scene objects which demonstrated sharp high contrast edge responses. Radiometric evaluation included detector relative calibration, effects of resampling, and coherent noise effects. Information content evaluation was carried out using clustering, principal components, transformed divergence separability measure, and supervised classifiers on test data. A detailed spectral class analysis (multispectral classification) was carried out to compare the information content of the MSS and TM for a large number of scene classes. A temperature-mapping experiment was carried out for a cooling pond to test the quality of thermal-band calibration. Overall TM data quality is very good. The MSS data are noisier than previous LANDSAT results.

  19. [Phantom studies of ultrasound equipment for quality improvement in breast diagnosis].

    PubMed

    Madjar, H; Mundinger, A; Lattermann, U; Gufler, H; Prömpeler, H J

    1996-04-01

    According to the German guidelines for quality control of ultrasonic equipment, the following conditions are required for breast ultrasound: A transducer frequency between 5-7.5 MHz and a minimum field of view of 5 cm. Satisfactory images must be obtained in a depth between 0.5 and 4 cm with a wide tolerance of the focal zones. This allows the use of poor quality equipment which does not produce satisfactory image quality and it excludes a number of high frequency and high resolution transducers with a field of view below 5 cm. This study with a test phantom was performed to define image quality objectively. Sixteen ultrasound instruments in different price categories were used to perform standardized examinations on a breast phantom model 550 (ATS Laboratories, Bridgeport, USA). Contrast and spatial resolution in different penetration depths were investigated on cyst phantoms from 1-4 mm diameter and wire targets with defined distances between 0.5-3 mm 4 investigations reported the images. A positive correlation was seen between price category and image quality. This study demonstrates that transducer frequency and image geometry do not allow sufficient quality control. An improvement of ultrasound diagnosis is only possible if equipment guidelines are based on standard examinations with test phantoms.

  20. Higher quality of molecular testing, an unfulfilled priority: Results from external quality assessment for KRAS mutation testing in colorectal cancer.

    PubMed

    Tembuyser, Lien; Ligtenberg, Marjolijn J L; Normanno, Nicola; Delen, Sofie; van Krieken, J Han; Dequeker, Elisabeth M C

    2014-05-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European Society of Pathology has been organizing an annual KRAS external quality assessment program since 2009. In 2012, 10 formalin-fixed, paraffin-embedded samples, of which 8 from invasive metastatic colorectal cancer tissue and 2 artificial samples of cell line material, were sent to more than 100 laboratories from 26 countries with a request for routine KRAS testing. Both genotyping and clinical reports were assessed independently. Twenty-seven percent of the participants genotyped at least 1 of 10 samples incorrectly. In total, less than 5% of the distributed specimens were genotyped incorrectly. Genotyping errors consisted of false negatives, false positives, and incorrectly genotyped mutations. Twenty percent of the laboratories reported a technical error for one or more samples. A review of the written reports showed that several essential elements were missing, most notably a clinical interpretation of the test result, the method sensitivity, and the use of a reference sequence. External quality assessment serves as a valuable educational tool in assessing and improving molecular testing quality and is an important asset for monitoring quality assurance upon incorporation of new biomarkers in diagnostic services. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  1. A quality quantitative method of silicon direct bonding based on wavelet image analysis

    NASA Astrophysics Data System (ADS)

    Tan, Xiao; Tao, Zhi; Li, Haiwang; Xu, Tiantong; Yu, Mingxing

    2018-04-01

    The rapid development of MEMS (micro-electro-mechanical systems) has received significant attention from researchers in various fields and subjects. In particular, the MEMS fabrication process is elaborate and, as such, has been the focus of extensive research inquiries. However, in MEMS fabrication, component bonding is difficult to achieve and requires a complex approach. Thus, improvements in bonding quality are relatively important objectives. A higher quality bond can only be achieved with improved measurement and testing capabilities. In particular, the traditional testing methods mainly include infrared testing, tensile testing, and strength testing, despite the fact that using these methods to measure bond quality often results in low efficiency or destructive analysis. Therefore, this paper focuses on the development of a precise, nondestructive visual testing method based on wavelet image analysis that is shown to be highly effective in practice. The process of wavelet image analysis includes wavelet image denoising, wavelet image enhancement, and contrast enhancement, and as an end result, can display an image with low background noise. In addition, because the wavelet analysis software was developed with MATLAB, it can reveal the bonding boundaries and bonding rates to precisely indicate the bond quality at all locations on the wafer. This work also presents a set of orthogonal experiments that consist of three prebonding factors, the prebonding temperature, the positive pressure value and the prebonding time, which are used to analyze the prebonding quality. This method was used to quantify the quality of silicon-to-silicon wafer bonding, yielding standard treatment quantities that could be practical for large-scale use.

  2. Broken Gears: The Value Added of Higher Education on Teachers' Academic Achievement

    ERIC Educational Resources Information Center

    Balcázar, Carlos Felipe; Ñopo, Hugo

    2016-01-01

    Good teachers are essential for high-quality educational systems. However, little is known about teachers' skill formation during college. By combining two standardized tests for Colombian students, one taken at the end of senior year in high school and the other when students are near graduation from college, we test the extent to which students…

  3. Subjective evaluation of next-generation video compression algorithms: a case study

    NASA Astrophysics Data System (ADS)

    De Simone, Francesca; Goldmann, Lutz; Lee, Jong-Seok; Ebrahimi, Touradj; Baroncini, Vittorio

    2010-08-01

    This paper describes the details and the results of the subjective quality evaluation performed at EPFL, as a contribution to the effort of the Joint Collaborative Team on Video Coding (JCT-VC) for the definition of the next-generation video coding standard. The performance of 27 coding technologies have been evaluated with respect to two H.264/MPEG-4 AVC anchors, considering high definition (HD) test material. The test campaign involved a total of 494 naive observers and took place over a period of four weeks. While similar tests have been conducted as part of the standardization process of previous video coding technologies, the test campaign described in this paper is by far the most extensive in the history of video coding standardization. The obtained subjective quality scores show high consistency and support an accurate comparison of the performance of the different coding solutions.

  4. Residual risk of bacterial contamination of platelets: six years of experience with sterility testing.

    PubMed

    Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy

    2017-09-01

    Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.

  5. Maternal Depression and Parenting in Early Childhood: Contextual Influence of Marital Quality and Social Support in Two Samples

    PubMed Central

    Taraban, Lindsay; Shaw, Daniel S.; Leve, Leslie D.; Wilson, Melvin N.; Dishion, Thomas J.; Natsuaki, Misaki N.; Neiderhiser, Jenae M.; Reiss, David

    2016-01-01

    Marital quality and social support satisfaction were tested as moderators of the association between maternal depressive symptoms and parenting during early childhood (18-36 months) among two large, divergent, longitudinal samples (n = 526; n = 570). Unexpectedly, in both samples the association between maternal depressive symptoms and reduced parenting quality was strongest in the context of high marital quality and high social support, and largely non-significant in the context of low marital quality and low social support. Possible explanations for these surprising findings are discussed. Results point to the importance of accounting for factors in the broader family context in predicting the association between depressive symptoms and maternal parenting. PMID:28230401

  6. An interactive Doppler velocity dealiasing scheme

    NASA Astrophysics Data System (ADS)

    Pan, Jiawen; Chen, Qi; Wei, Ming; Gao, Li

    2009-10-01

    Doppler weather radars are capable of providing high quality wind data at a high spatial and temporal resolution. However, operational application of Doppler velocity data from weather radars is hampered by the infamous limitation of the velocity ambiguity. This paper reviews the cause of velocity folding and presents the unfolding method recently implemented for the CINRAD systems. A simple interactive method for velocity data, which corrects de-aliasing errors, has been developed and tested. It is concluded that the algorithm is very efficient and produces high quality velocity data.

  7. Impact of emerging health insurance arrangements on diabetes outcomes and disparities: rationale and study design.

    PubMed

    Wharam, J Frank; Soumerai, Steve; Trinacty, Connie; Eggleston, Emma; Zhang, Fang; LeCates, Robert; Canning, Claire; Ross-Degnan, Dennis

    2013-01-01

    Consumer-directed health plans combine lower premiums with high annual deductibles, Internet-based quality-of-care information, and health savings mechanisms. These plans may encourage members to seek better value for health expenditures but may also decrease essential care. The expansion of high-deductible health plans (HDHPs) represents a natural experiment of tremendous proportion. We designed a pre-post, longitudinal, quasi-experimental study to determine the effect of HDHPs on diabetes quality of care, outcomes, and disparities. We will use a 13-year rolling sample (2001-2013) of members of an HDHP and members of a control group. To reduce selection bias, we will limit participants to those whose employers mandate a single health insurance type. The study will measure rates of monthly hemoglobin A1c, lipid, and albuminuria testing; availability of blood glucose test strips; and rates of retinal examinations, high-severity emergency department visits, and preventable hospitalizations. Results could be used to design health plan features that promote high-quality care and better outcomes among people who have diabetes.

  8. Tank 241-AY-101 Privatization Push Mode Core Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-01-12

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for samples obtained from tank 241-AY-101. The purpose of this sampling event is to obtain information about the characteristics of the contents of 241-AY-101 required to satisfy Data Quality Objectives For RPP Privatization Phase I: Confirm Tank T Is An Appropriate Feed Source For High-Level Waste Feed Batch X(HLW DQO) (Nguyen 1999a), Data Quality Objectives For TWRS Privatization Phase I : Confirm Tank T Is An Appropriate Feed Source For Low-Activity Waste Feed Batch X (LAW DQO) (Nguyen 1999b), Low Activitymore » Waste and High-Level Waste Feed Data Quality Objectives (L and H DQO) (Patello et al. 1999), and Characterization Data Needs for Development, Design, and Operation of Retrieval Equipment Developed through the Data Quality Objective Process (Equipment DQO) (Bloom 1996). Special instructions regarding support to the LAW and HLW DQOs are provided by Baldwin (1999). Push mode core samples will be obtained from risers 15G and 150 to provide sufficient material for the chemical analyses and tests required to satisfy these data quality objectives. The 222-S Laboratory will extrude core samples; composite the liquids and solids; perform chemical analyses on composite and segment samples; archive half-segment samples; and provide subsamples to the Process Chemistry Laboratory. The Process Chemistry Laboratory will prepare test plans and perform process tests to evaluate the behavior of the 241-AY-101 waste undergoing the retrieval and treatment scenarios defined in the applicable DQOs. Requirements for analyses of samples originating in the process tests will be documented in the corresponding test plans and are not within the scope of this SAP.« less

  9. Tank 241-AY-101 Privatization Push Mode Core Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-05-19

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for samples obtained from tank 241-AY-101. The purpose of this sampling event is to obtain information about the characteristics of the contents of 241-AY-101 required to satisfy ''Data Quality Objectives For RPP Privatization Phase I: Confirm Tank T Is An Appropriate Feed Source For High-Level Waste Feed Batch X(HLW DQO)' (Nguyen 1999a), ''Data Quality Objectives For TWRS Privatization Phase I: Confirm Tank T Is An Appropriate Feed Source For Low-Activity Waste Feed Butch X (LAW DQO) (Nguyen 1999b)'', ''Low Activity Wastemore » and High-Level Waste Feed Data Quality Objectives (L&H DQO)'' (Patello et al. 1999), and ''Characterization Data Needs for Development, Design, and Operation of Retrieval Equipment Developed through the Data Quality Objective Process (Equipment DQO)'' (Bloom 1996). Special instructions regarding support to the LAW and HLW DQOs are provided by Baldwin (1999). Push mode core samples will be obtained from risers 15G and 150 to provide sufficient material for the chemical analyses and tests required to satisfy these data quality objectives. The 222-S Laboratory will extrude core samples; composite the liquids and solids; perform chemical analyses on composite and segment samples; archive half-segment samples; and provide sub-samples to the Process Chemistry Laboratory. The Process Chemistry Laboratory will prepare test plans and perform process tests to evaluate the behavior of the 241-AY-101 waste undergoing the retrieval and treatment scenarios defined in the applicable DQOs. Requirements for analyses of samples originating in the process tests will be documented in the corresponding test plans and are not within the scope of this SAP.« less

  10. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    PubMed

    Furtado, Fabianne; Gonçalves, Bruno da Silva B; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia; Forner-Cordero, Arturo

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  11. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults

    PubMed Central

    Gonçalves, Bruno da Silva B.; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation. PMID:27732604

  12. A Microfluidic Immunostaining System Enables Quality Assured and Standardized Immunohistochemical Biomarker Analysis

    NASA Astrophysics Data System (ADS)

    Kwon, Seyong; Cho, Chang Hyun; Kwon, Youngmee; Lee, Eun Sook; Park, Je-Kyun

    2017-04-01

    Immunohistochemistry (IHC) plays an important role in biomarker-driven cancer therapy. Although there has been a high demand for standardized and quality assured IHC, it has rarely been achieved due to the complexity of IHC testing and the subjective validation-based process flow of IHC quality control. We present here a microfluidic immunostaining system for the standardization of IHC by creating a microfluidic linearly graded antibody (Ab)-staining device and a reference cell microarray. Unlike conventional efforts, our system deals primarily with the screening of biomarker staining conditions for quantitative quality assurance testing in IHC. We characterized the microfluidic matching of Ab staining intensity using three HER2 Abs produced by different manufacturers. The quality of HER2 Ab was also validated using tissues of breast cancer patients, demonstrating that our system is an efficient and powerful tool for the standardization and quality assurance of IHC.

  13. Quality Assessment of A356 Ingots from Different Suppliers in Wheel Production

    NASA Astrophysics Data System (ADS)

    Koca, Emre; Yuksel, Caglar; Erzi, Eray; Dışpınar, Derya

    In a typical foundry floor, several precautions are taken prior to the casting in order to achieve pore-free, high quality parts. In low pressure die castings, these operations involve runner design, pressure adjustment, die temperature selection, cooling locations etc. For the melt, it is important to determine the degassing duration and gas flow rate. In addition, the period of modification (Ti, Sr) addition also plays a significant role. Even after optimization of all these parameters, reject parts can still be found. What has always been disregarded is the quality assessment of the ingot suppliers. Therefore, in this work, four different A356 ingot provider's quality has been investigated in the wheel producer company. Reduced pressure test was used to quantify melt quality by means of bifilm index measurement. In addition, fluidity, feedability and tensile tests have been carried out. The rejection rates were compared according to provider's quality level.

  14. Fast and precise dense grid size measurement method based on coaxial dual optical imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Jiping; Peng, Xiang; Yu, Jiping; Hao, Jian; Diao, Yan; Song, Tao; Li, Ameng; Lu, Xiaowei

    2015-10-01

    Test sieves with dense grid structure are widely used in many fields, accurate gird size calibration is rather critical for success of grading analysis and test sieving. But traditional calibration methods suffer from the disadvantages of low measurement efficiency and shortage of sampling number of grids which could lead to quality judgment risk. Here, a fast and precise test sieve inspection method is presented. Firstly, a coaxial imaging system with low and high optical magnification probe is designed to capture the grid images of the test sieve. Then, a scaling ratio between low and high magnification probes can be obtained by the corresponding grids in captured images. With this, all grid dimensions in low magnification image can be obtained by measuring few corresponding grids in high magnification image with high accuracy. Finally, by scanning the stage of the tri-axis platform of the measuring apparatus, whole surface of the test sieve can be quickly inspected. Experiment results show that the proposed method can measure the test sieves with higher efficiency compare to traditional methods, which can measure 0.15 million grids (gird size 0.1mm) within only 60 seconds, and it can measure grid size range from 20μm to 5mm precisely. In a word, the presented method can calibrate the grid size of test sieve automatically with high efficiency and accuracy. By which, surface evaluation based on statistical method can be effectively implemented, and the quality judgment will be more reasonable.

  15. [The evaluation of physical development of students].

    PubMed

    2012-01-01

    The article demonstrates that physical health of university students is conditioned by the aggregate of morpho-functional indices and depends on the development of physical qualities of students. The evaluation of mass/height indicators of female students demonstrates the increase of total body size and weakness of body build. The testing of physical readiness testified the ambiguity of high-speed and high-speed/power qualities and results of stamina evaluation.

  16. Relationship between Tree Value, Diameter, and Age in High-Quality Sugar Maple (Acer saccharum) on the Menominee Reservation, Wisconsin

    Treesearch

    Daniel C. Dey; John Dwyer; Jan Wiedenbeck

    2017-01-01

    Guidelines for managing sugar maple-dominated forests by the single-tree selection method are well established and widely adopted. The forests of the Menominee Tribe in Wisconsin provide an opportunity to validate current guidelines by testing tree value and size/age relationships in forests that have substantially older and larger high-quality trees than can be found...

  17. Does clinical pretest probability influence image quality and diagnostic accuracy in dual-source coronary CT angiography?

    PubMed

    Thomas, Christoph; Brodoefel, Harald; Tsiflikas, Ilias; Bruckner, Friederike; Reimann, Anja; Ketelsen, Dominik; Drosch, Tanja; Claussen, Claus D; Kopp, Andreas; Heuschmid, Martin; Burgstahler, Christof

    2010-02-01

    To prospectively evaluate the influence of the clinical pretest probability assessed by the Morise score onto image quality and diagnostic accuracy in coronary dual-source computed tomography angiography (DSCTA). In 61 patients, DSCTA and invasive coronary angiography were performed. Subjective image quality and accuracy for stenosis detection (>50%) of DSCTA with invasive coronary angiography as gold standard were evaluated. The influence of pretest probability onto image quality and accuracy was assessed by logistic regression and chi-square testing. Correlations of image quality and accuracy with the Morise score were determined using linear regression. Thirty-eight patients were categorized into the high, 21 into the intermediate, and 2 into the low probability group. Accuracies for the detection of significant stenoses were 0.94, 0.97, and 1.00, respectively. Logistic regressions and chi-square tests showed statistically significant correlations between Morise score and image quality (P < .0001 and P < .001) and accuracy (P = .0049 and P = .027). Linear regression revealed a cutoff Morise score for a good image quality of 16 and a cutoff for a barely diagnostic image quality beyond the upper Morise scale. Pretest probability is a weak predictor of image quality and diagnostic accuracy in coronary DSCTA. A sufficient image quality for diagnostic images can be reached with all pretest probabilities. Therefore, coronary DSCTA might be suitable also for patients with a high pretest probability. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  18. LIHE Spectral Dynamics and Jaguar Data Acquisition System Measurement Assurance Results 2014.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Covert, Timothy T.; Willis, Michael David; Radtke, Gregg Arthur

    2015-06-01

    The Light Initiated High Explosive (LIHE) facility performs high rigor, high consequence impulse testing for the nuclear weapons (NW) community. To support the facility mission, LIHE's extensive data acquisition system (DAS) is comprised of several discrete components as well as a fully integrated system. Due to the high consequence and high rigor of the testing performed at LIHE, a measurement assurance plan (MAP) was developed in collaboration with NW system customers to meet their data quality needs and to provide assurance of the robustness of the LIHE DAS. While individual components of the DAS have been calibrated by the SNLmore » Primary Standards Laboratory (PSL), the integrated nature of this complex system requires verification of the complete system, from end-to-end. This measurement assurance plan (MAP) report documents the results of verification and validation procedures used to ensure that the data quality meets customer requirements.« less

  19. Development and flight test of an experimental maneuver autopilot for a highly maneuverable aircraft

    NASA Technical Reports Server (NTRS)

    Duke, Eugene L.; Jones, Frank P.; Roncoli, Ralph B.

    1986-01-01

    This report presents the development of an experimental flight test maneuver autopilot (FTMAP) for a highly maneuverable aircraft. The essence of this technique is the application of an autopilot to provide precise control during required flight test maneuvers. This newly developed flight test technique is being applied at the Dryden Flight Research Facility of NASA Ames Research Center. The FTMAP is designed to increase the quantity and quality of data obtained in test flight. The technique was developed and demonstrated on the highly maneuverable aircraft technology (HiMAT) vehicle. This report describes the HiMAT vehicle systems, maneuver requirements, FTMAP development process, and flight results.

  20. Quality of Voluntary Medical Male Circumcision Services during Scale-Up: A Comparative Process Evaluation in Kenya, South Africa, Tanzania and Zimbabwe

    PubMed Central

    Jennings, Larissa; Bertrand, Jane; Rech, Dino; Harvey, Steven A.; Hatzold, Karin; Samkange, Christopher A.; Omondi Aduda, Dickens S.; Fimbo, Bennett; Cherutich, Peter; Perry, Linnea; Castor, Delivette; Njeuhmeli, Emmanuel

    2014-01-01

    Background The rapid expansion of voluntary medical male circumcision (VMMC) has raised concerns whether health systems can deliver and sustain VMMC according to minimum quality criteria. Methods and Findings A comparative process evaluation was used to examine data from SYMMACS, the Systematic Monitoring of the Voluntary Medical Male Circumcision Scale-Up, among health facilities providing VMMC across two years of program scale-up. Site-level assessments examined the availability of guidelines, supplies and equipment, infection control, and continuity of care services. Direct observation of VMMC surgeries were used to assess care quality. Two sample tests of proportions and t-tests were used to examine differences in the percent of facilities meeting requisite preparedness standards and the mean number of directly-observed surgical tasks performed correctly. Results showed that safe, high quality VMMC can be implemented and sustained at-scale, although substantial variability was observed over time. In some settings, facility preparedness and VMMC service quality improved as the number of VMMC facilities increased. Yet, lapses in high performance and expansion of considerably deficient services were also observed. Surgical tasks had the highest quality scores, with lower performance levels in infection control, pre-operative examinations, and post-operative patient monitoring and counseling. The range of scale-up models used across countries additionally underscored the complexity of delivering high quality VMMC. Conclusions Greater efforts are needed to integrate VMMC scale-up and quality improvement processes in sub-Saharan African settings. Monitoring of service quality, not just adverse events reporting, will be essential in realizing the full health impact of VMMC for HIV prevention. PMID:24801073

  1. Pathfinder Innovation Projects: Awardees for 2011

    EPA Pesticide Factsheets

    First-year PIP awardees pursue high-risk, high-reward research with project topics such as bacteria in drinking water pipes, biomarkers in sewage, endocrine disruption using glowing frogs, and testing water quality from space.

  2. TREAT Asia Quality Assessment Scheme (TAQAS) to standardize the outcome of HIV genotypic resistance testing in a group of Asian laboratories

    PubMed Central

    Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew

    2010-01-01

    The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972

  3. Nutritional quality of diet and academic performance in Chilean students.

    PubMed

    Correa-Burrows, Paulina; Burrows, Raquel; Blanco, Estela; Reyes, Marcela; Gahagan, Sheila

    2016-03-01

    To explore associations between the nutritional quality of diet at age 16 years and academic performance in students from Santiago, Chile. We assessed the nutritional quality of diet, using a validated food frequency questionnaire, in 395 students aged 16.8 ± 0.5 years. Depending on the amount of saturated fat, fibre, sugar and salt in the foods, diet was categorized as unhealthy, fair or healthy. Academic performance was assessed using high school grade-point average (GPA) and tests for college admission in language and mathematics. Academic results on or above the 75th percentile in our sample were considered good academic performance. We tested associations between nutritional quality of diet and good academic performance using logistic regression models. We considered sociodemographic, educational and body-mass index (BMI) factors as potential confounders. After controlling for potential confounding factors, an unhealthy diet at age 16 years was associated with reduced academic performance. Compared to participants with healthy diets, those with unhealthy diets were significantly less likely to perform well based on language tests (odds ratio, OR: 0.42; 95% confidence interval, CI: 0.18-0.98) mathematics tests (OR: 0.35; 95% CI: 0.15-0.82) or GPA (OR: 0.22; 95% CI: 0.09-0.56). In our sample, excessive consumption of energy-dense, low-fibre, high-fat foods at age 16 years was associated with reduced academic performance.

  4. Skype Synchronous Interaction Effectiveness in a Quantitative Management Science Course

    ERIC Educational Resources Information Center

    Strang, Kenneth David

    2012-01-01

    An experiment compared asynchronous versus synchronous instruction in an online quantitative course. Mann-Whitney U-tests, correlation, analysis of variance, t tests, and multivariate analysis of covariance (MANCOVA) were utilized to test the hypothesis that more high-quality online experiential learning interactions would increase grade.…

  5. Highlights from High Energy Neutrino Experiments at CERN

    NASA Astrophysics Data System (ADS)

    Schlatter, W.-D.

    2015-07-01

    Experiments with high energy neutrino beams at CERN provided early quantitative tests of the Standard Model. This article describes results from studies of the nucleon quark structure and of the weak current, together with the precise measurement of the weak mixing angle. These results have established a new quality for tests of the electroweak model. In addition, the measurements of the nucleon structure functions in deep inelastic neutrino scattering allowed first quantitative tests of QCD.

  6. Perception of synthetic speech produced automatically by rule: Intelligibility of eight text-to-speech systems

    PubMed Central

    GREENE, BETH G.; LOGAN, JOHN S.; PISONI, DAVID B.

    2012-01-01

    We present the results of studies designed to measure the segmental intelligibility of eight text-to-speech systems and a natural speech control, using the Modified Rhyme Test (MRT). Results indicated that the voices tested could be grouped into four categories: natural speech, high-quality synthetic speech, moderate-quality synthetic speech, and low-quality synthetic speech. The overall performance of the best synthesis system, DECtalk-Paul, was equivalent to natural speech only in terms of performance on initial consonants. The findings are discussed in terms of recent work investigating the perception of synthetic speech under more severe conditions. Suggestions for future research on improving the quality of synthetic speech are also considered. PMID:23225916

  7. The impact of flying qualities on helicopter operational agility

    NASA Technical Reports Server (NTRS)

    Padfield, Gareth D.; Lappos, Nick; Hodgkinson, John

    1993-01-01

    Flying qualities standards are formally set to ensure safe flight and therefore reflect minimum, rather than optimum, requirements. Agility is a flying quality but relates to operations at high, if not maximum, performance. While the quality metrics and test procedures for flying, as covered for example in ADS33C, may provide an adequate structure to encompass agility, they do not currently address flight at high performance. This is also true in the fixed-wing world and a current concern in both communities is the absence of substantiated agility criteria and possible conflicts between flying qualities and high performance. AGARD is sponsoring a working group (WG19) title 'Operational Agility' that deals with these and a range of related issues. This paper is condensed from contributions by the three authors to WG19, relating to flying qualities. Novel perspectives on the subject are presented including the agility factor, that quantifies performance margins in flying qualities terms; a new parameter, based on maneuver acceleration is introduced as a potential candidate for defining upper limits to flying qualities. Finally, a probabilistic analysis of pilot handling qualities ratings is presented that suggests a powerful relationship between inherent airframe flying qualities and operational agility.

  8. Comparing the cognitive, personality and moral characteristics of high school and graduate medical entrants to the Tehran University of Medical Sciences in Iran.

    PubMed

    Nedjat, Saharnaz; Bore, Miles; Majdzadeh, Reza; Rashidian, Arash; Munro, Don; Powis, David; Karbakhsh, Mojgan; Keshavarz, Hossein

    2013-12-01

    Tehran University of Medical Sciences has two streams of medical student admission: an established high school entry (HSE) route and an experimental graduate entry (GE) route. To compare the cognitive skills, personality traits and moral characteristics of HSE and GE students admitted to this university. The personal qualities assessment tool (PQA; www.pqa.net.au ) was translated from English to Persian and then back-translated. Afterwards 35 individuals from the GE and 109 individuals from the 2007 to 2008 HSE completed the test. The results were compared by t-test and Chi-square. The HSE students showed significantly higher ability in the cognitive skills tests (p < 0.001). They were also more libertarian (p = 0.022), but had lower ability to confront stress and unpleasant events (p < 0.001), and had lower self-awareness and self-control (p < 0.001). On the basis of their personal qualities, the GE students had more self-control and strength when coping with stress than the HSE students, but the latter had superior cognitive abilities. Hence it may be useful to include cognitive tests in GE students' entry exam and include tests of personal qualities to exclude those with unsuitable characteristics.

  9. Using the Cross-Correlation Function to Evaluate the Quality of Eddy-Covariance Data

    NASA Astrophysics Data System (ADS)

    Qi, Yongfeng; Shang, Xiaodong; Chen, Guiying; Gao, Zhiqiu; Bi, Xueyan

    2015-11-01

    A cross-correlation test is proposed for evaluating the quality of 30-min eddy-covariance data. Cross-correlation as a function of time lag is computed for vertical velocity paired with temperature, humidity, and carbon dioxide concentration. High quality data have a dominant peak at zero time lag and approach zero within a time lag of 20 s. Poor quality data have erratic cross-correlation functions, which indicates that the eddy flux may no longer represent the energy and mass exchange between the atmospheric surface layer and the canopy, and such data should be rejected in post-data analyses. Eddy-covariance data over grassland in July 2004 are used to evaluate the proposed test. The results show that 17, 29, and 36 % of the available data should be rejected because of poor quality measurements of sensible heat, latent heat, and CO2 fluxes, respectively. The rejected data mainly occurred on calm nights and day/night transitions when the atmospheric surface layer became stable or neutrally stratified. We found no friction velocity (u_*) threshold below which all data should be rejected, a test that many other studies have implemented for rejecting questionable data. We instead found that some data with low u_* were reliable, whereas other data with higher u_* were not. The poor quality measurements collected under less than ideal conditions were replaced by using the mean diurnal variation gap-filling method. The correction for poor quality data shifted the daily average CO2 flux by +0.34 g C m^{-2} day^{-1}. After applying the quality-control test, the eddy CO2 fluxes did not display a clear dependence on u_*. The results suggest that the cross-correlation test is a potentially valuable step in evaluating the quality of eddy-covariance data.

  10. Preparation and Characterization of Cyclotrimethylenetrinitramine (RDX) with Reduced Sensitivity

    PubMed Central

    Wang, Yuqiao; Li, Xin; Chen, Shusen; Ma, Xiao; Yu, Ziyang; Jin, Shaohua; Li, Lijie; Chen, Yu

    2017-01-01

    The internal defects and shape of cyclotrimethylenetrinitramine (RDX) crystal are critical parameters for the preparation of reduced sensitivity RDX (RS-RDX). In the current study, RDX was re-crystallized and spheroidized to form the high-quality RDX that was further characterized by purity, apparent density, size distribution, specific surface area, impact sensitivity, and shock sensitivity. The effects of re-crystallization solvent on the growth morphology of RDX crystal were investigated by both theoretical simulation and experiment test, and consistent results were obtained. The high-quality RDX exhibited a high purity (≥99.90%), high apparent density (≥1.811 g/cm3), spherical shape, and relatively low impact sensitivity (6%). Its specific surface area was reduced more than 30%. Compared with conventional RDXs, the high-quality RDX reduced the shock sensitivities of PBXN-109 and PBXW-115 by more than 30%, indicating that it was a RS-RDX. The reduced sensitivity and good processability of the high-quality RDX would be significant in improving the performances of RDX-based PBXs. PMID:28825661

  11. High cortisol levels are associated with low quality food choice in type 2 diabetes.

    PubMed

    Duong, Michelle; Cohen, Jessica I; Convit, Antonio

    2012-02-01

    Hypothalamic-pituitary-adrenal (HPA) axis control may be impaired in type 2 diabetes (T2DM). Glucocorticoids increase consumption of low quality foods high in calories, sugar, and fat. We explored the relationship between cortisol levels, poor blood glucose control, and food quality choice in T2DM. Twenty-seven healthy controls were age-, gender- and education-matched to 27 T2DM participants. Standard clinical blood tests and cortisol values were measured from fasting blood samples. Participants recorded all consumed food and drink items in a consecutive 3-day food diary. Diaries were analyzed for "high quality" and "low quality" foods using a standardized method with high reliability (0.97 and 0.86, respectively). Controlling for education, body mass index (BMI) and hemoglobin A1C (HbA1C), log-transformed cortisol (LogC) predicted the percent of low quality foods (R (2) = 0.092, β = 0.360, P < 0.05), but not the percent of high quality foods chosen. Controlling for education, BMI, and LogC, HbA1C significantly predicted both the percent of low quality foods (ΔR (2) = 0.079, β = 0.348, P = 0.024) and high quality foods chosen (ΔR (2) = 0.085, β = -0.362, P = 0.022). The relationship between HbA1C and low quality food choice may be mediated by cortisol, controlling for BMI and education (P < 0.01). HbA1C displayed both an indirect (cortisol-mediated) effect (P < 0.05) and direct effect on low quality food choice (P < 0.05). The relationship between HbA1C and low quality food choice may be partially mediated by cortisol. Poor blood glucose control may cause HPA axis disruption, increased consumption of low quality foods.

  12. VERIFYING THE VOC CONTROL PERFORMANCE OF BIOREACTORS

    EPA Science Inventory

    The paper describes the verification testing approach used to collect high-quality, peer-reviewed data on the performance of bioreaction-based technologies for the control of volatile organic compounds (VOCs). The verification protocol that describes the approach for these tests ...

  13. Automated water monitor system field demonstration test report. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.

    1981-01-01

    The NASA Automatic Water Monitor System was installed in a water reclamation facility to evaluate the technical and cost feasibility of producing high quality reclaimed water. Data gathered during this field demonstration test are reported.

  14. 76 FR 35072 - Proposed Guidance on Stress Testing for Banking Organizations With More Than $10 Billion in Total...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-15

    ... ensure that each is conceptually sound. Stress tests usually vary in design and complexity, including the... quantitative tests supported by high-quality data, employ a certain amount of expert or business judgment that... generally, enterprise-wide stress testing involves robust scenario design and effective translation of...

  15. Development and validation of a tool to evaluate the quality of medical education websites in pathology

    PubMed Central

    Alyusuf, Raja H.; Prasad, Kameshwar; Abdel Satir, Ali M.; Abalkhail, Ali A.; Arora, Roopa K.

    2013-01-01

    Background: The exponential use of the internet as a learning resource coupled with varied quality of many websites, lead to a need to identify suitable websites for teaching purposes. Aim: The aim of this study is to develop and to validate a tool, which evaluates the quality of undergraduate medical educational websites; and apply it to the field of pathology. Methods: A tool was devised through several steps of item generation, reduction, weightage, pilot testing, post-pilot modification of the tool and validating the tool. Tool validation included measurement of inter-observer reliability; and generation of criterion related, construct related and content related validity. The validated tool was subsequently tested by applying it to a population of pathology websites. Results and Discussion: Reliability testing showed a high internal consistency reliability (Cronbach's alpha = 0.92), high inter-observer reliability (Pearson's correlation r = 0.88), intraclass correlation coefficient = 0.85 and κ =0.75. It showed high criterion related, construct related and content related validity. The tool showed moderately high concordance with the gold standard (κ =0.61); 92.2% sensitivity, 67.8% specificity, 75.6% positive predictive value and 88.9% negative predictive value. The validated tool was applied to 278 websites; 29.9% were rated as recommended, 41.0% as recommended with caution and 29.1% as not recommended. Conclusion: A systematic tool was devised to evaluate the quality of websites for medical educational purposes. The tool was shown to yield reliable and valid inferences through its application to pathology websites. PMID:24392243

  16. [Establishment of Quality Control System of Nucleic Acid Detection for Ebola Virus in Sierra Leone-China Friendship Biological Safety Laboratory].

    PubMed

    Wang, Qin; Zhang, Yong; Nie, Kai; Wang, Huanyu; Du, Haijun; Song, Jingdong; Xiao, Kang; Lei, Wenwen; Guo, Jianqiang; Wei, Hejiang; Cai, Kun; Wang, Yanhai; Wu, Jiang; Gerald, Bangura; Kamara, Idrissa Laybohr; Liang, Mifang; Wu, Guizhen; Dong, Xiaoping

    2016-03-01

    The quality control process throughout the Ebola virus nucleic acid detection in Sierra Leone-China Friendship Biological Safety Laboratory (SLE-CHN Biosafety Lab) was described in detail, in order to comprehensively display the scientific, rigorous, accurate and efficient practice in detection of Ebola virus of first batch detection team in SLE-CHN Biosafety Lab. Firstly, the key points of laboratory quality control system was described, including the managements and organizing, quality control documents and information management, instrument, reagents and supplies, assessment, facilities design and space allocation, laboratory maintenance and biosecurity. Secondly, the application of quality control methods in the whole process of the Ebola virus detection, including before the test, during the test and after the test, was analyzed. The excellent and professional laboratory staffs, the implementation of humanized management are the cornerstone of the success; High-level biological safety protection is the premise for effective quality control and completion of Ebola virus detection tasks. And professional logistics is prerequisite for launching the laboratory diagnosis of Ebola virus. The establishment and running of SLE-CHN Biosafety Lab has landmark significance for the friendship between Sierra Leone and China, and the lab becomes the most important base for Ebola virus laboratory testing in Sierra Leone.

  17. Hepatitis C Core Antigen Testing for Diagnosis of Hepatitis C Virus Infection: A Systematic Review and Meta-analysis.

    PubMed

    Freiman, J Morgan; Tran, Trang M; Schumacher, Samuel G; White, Laura F; Ongarello, Stefano; Cohn, Jennifer; Easterbrook, Philippa J; Linas, Benjamin P; Denkinger, Claudia M

    2016-09-06

    Diagnosis of chronic hepatitis C virus (HCV) infection requires both a positive HCV antibody screen and confirmatory nucleic acid testing (NAT). Testing for hepatitis C virus core antigen (HCVcAg) is a potential alternative to NAT. To evaluate the accuracy of diagnosis of active HCV infection among adults and children for 5 HCVcAg tests compared with NAT. EMBASE, PubMed, Web of Science, Scopus, and Cochrane Database of Systematic Reviews from 1990 through 31 March 2016. Case-control, cross-sectional, cohort, or randomized trials that compared any of 5 HCVcAg tests with an NAT reference standard. 2 independent reviewers extracted data and assessed quality using an adapted QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool. 44 studies evaluated 5 index tests. Studies for the Abbott ARCHITECT HCV Ag assay had the highest quality, whereas those for the Ortho HCV Ag enzyme-linked immunosorbent assay (ELISA) had the lowest quality. From bivariate analyses, the sensitivity and specificity of the assays were as follows: Abbott ARCHITECT, 93.4% (95% CI, 90.1% to 96.4%) and 98.8% (CI, 97.4% to 99.5%); Ortho ELISA, 93.2% (CI, 81.6% to 97.7%) and 99.2% (CI, 87.9% to 100%); and Hunan Jynda Bioengineering Group HCV Ag ELISA, 59.5% (CI, 46.0% to 71.7%) and 82.9% (CI, 58.6% to 94.3%). Insufficient data were available for a meta-analysis about the Fujirebio Lumipulse Ortho HCV Ag and Eiken Lumispot HCV Ag assays. In 3 quantitative studies using Abbott ARCHITECT, HCVcAg correlated closely with HCV RNA levels greater than 3000 IU/mL. Insufficient data were available on covariates, such as HIV or hepatitis B virus status, for subgroup analyses. Few studies reported genotypes of isolates, and data for genotypes 4, 5, and 6 were scant. Most studies were conducted in high-resource settings and reference laboratories. The HCVcAg assays with signal amplification have high sensitivity, high specificity, and good correlation with HCV RNA levels greater than 3000 IU/mL and have the potential to replace NAT in settings with high HCV prevalence. National Institutes of Health.

  18. Stroke and aphasia quality-of-life scale-39: Reliability and validity of the Turkish version.

    PubMed

    Noyan-ErbaŞ, AyŞin; Toğram, Bülent

    2016-10-01

    The aim of this study was to adapt the stroke and aphasia quality-of-life scale-39 (SAQoL-39) to the Turkish language and carry out a reliability and validity study of the instrument in a group of patients with aphasia. The study was a descriptive study and contained three phases: adaptation of the SAQoL-39 to the Turkish language, administration of the scale to 30 aphasia patients and reliability and validity studies of the scale. Internal consistency was assessed with Cronbach's alpha and test-re-test reliability was explored (n = 14). The adaptation process was completed based on inter-rater agreement on the translated items and within the scope of final editing by the authors of the study. The SAQoL-39 in Turkish exhibited high test-re-test reliability (ICC =0.97) as well as acceptability with minimal missing data (0-1.4). This instrument exhibited high internal consistency (Cronbach's α = 0.70-0.97), domain-total correlations (r = 0.76-0.85) and inter-domain correlations (r = 0.40-0.68). The analysis shows that the Turkish version of SAQoL-39 is a scale that is highly acceptable, valid and reliable and can be easily used in evaluating the quality-of-life of Turkish people with aphasia.

  19. Noninvasive pH monitoring of platelet concentrates: a large field test.

    PubMed

    Gkoumassi, Effimia; Klein-Bosgoed, Christa; Dijkstra-Tiekstra, Margriet J; de Korte, Dirk; de Wildt-Eggen, Janny

    2013-10-01

    Developing new quality control methods for platelet concentrates (PCs) can contribute to increasing transfusion safety and efficiency. The aim of this study was to investigate in a large field test the quality of expired PCs and whether 100% noninvasive pH monitoring can be used to predict PC quality. The pH of 13,693 PCs produced for transfusion was monitored daily using Blood Storage, Inc.'s pH sterile, automated fluoroscopic evaluation technology. Upon indication of compromised quality or expiration, PCs were returned and in vitro tests were performed. A total of 998 PCs were returned, of which 962 outdated, 26 had a positive BacT/ALERT reaction, seven had aggregates, one was without swirl, one had low pH, and one had high pH. BacT/ALERT was faster in identifying bacterial contamination than pH measurements. The pH at the end of the storage period was significantly lower than at the beginning. In vitro tests indicated that while the PC quality was acceptable upon expiration, it rapidly declined after expiration. In this setting where the vast majority of PCs were of good quality and within acceptable pH limits, daily, noninvasive routine pH measurement has limited added value in identifying quality-compromised PCs. © 2013 Sanquin Research. Transfusion © 2013 American Association of Blood Banks.

  20. Ground vibration tests of a high fidelity truss for verification of on orbit damage location techniques

    NASA Technical Reports Server (NTRS)

    Kashangaki, Thomas A. L.

    1992-01-01

    This paper describes a series of modal tests that were performed on a cantilevered truss structure. The goal of the tests was to assemble a large database of high quality modal test data for use in verification of proposed methods for on orbit model verification and damage detection in flexible truss structures. A description of the hardware is provided along with details of the experimental setup and procedures for 16 damage cases. Results from selected cases are presented and discussed. Differences between ground vibration testing and on orbit modal testing are also described.

  1. Development of high-average-power DPSSL with high beam quality

    NASA Astrophysics Data System (ADS)

    Nakai, Sadao; Kanabe, Tadashi; Kawashima, Toshiyuki; Yamanaka, Masanobu; Izawa, Yasukazu; Nakatuka, Masahiro; Kandasamy, Ranganathan; Kan, Hirofumi; Hiruma, Teruo; Niino, Masayuki

    2000-08-01

    The recent progress of high power diode laser is opening new fields of laser and its application. We are developing high average power diode pumped solid state laser DPSSL for laser fusion power plant, for space propulsion and for various applications in industry. The common features or requirements of our High Average-power Laser for Nuclear-fusion Application (HALNA) are large pulse energy with relatively low repetition of few tens Hz, good beam quality of order of diffraction limit and high efficiency more than 10%. We constructed HALNA 10 (10J X 10 Hz) and tested the performance to clarify the scalability to higher power system. We have obtained in a preliminary experiment a 8.5 J output energy at 0.5 Hz with beam quality of 2 times diffraction limited far-field pattern.

  2. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion.

    PubMed

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-09-02

    Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Quality of original and biosimilar epoetin products.

    PubMed

    Brinks, Vera; Hawe, Andrea; Basmeleh, Abdul H H; Joachin-Rodriguez, Liliana; Haselberg, Rob; Somsen, Govert W; Jiskoot, Wim; Schellekens, Huub

    2011-02-01

    To compare the quality of therapeutic erythropoietin (EPO) products, including two biosimilars, with respect to content, aggregation, isoform profile and potency. Two original products, Eprex (epoetin alpha) and Dynepo (epoetin delta), and two biosimilar products, Binocrit (epoetin alpha) and Retacrit (epoetin zeta), were compared using (1) high performance size exclusion chromatography, (2) ELISA, (3) SDS-PAGE, (4) capillary zone electrophoresis and (5) in-vivo potency. Tested EPO products differed in content, isoform composition, and potency. Of the tested products, the biosimilars have the same or even better quality as the originals. Especially, the potency of originals may significantly differ from the value on the label.

  4. Flight test results for several light, canard-configured airplanes

    NASA Technical Reports Server (NTRS)

    Brown, Philip W.

    1987-01-01

    Brief flight evaluations of two different, light, composite constructed, canard and winglet configured airplanes were performed to assess their handling qualities; one airplane was a single engine, pusher design and the other a twin engine, push-pull configuration. An emphasis was placed on the slow speed/high angle of attack region for both airplanes and on the engine-out regime for the twin. Mission suitability assessment included cockpit and control layout, ground and airborne handling qualities, and turbulence response. Very limited performance data was taken. Stall/spin tests and the effects of laminar flow loss on performance and handling qualities were assessed on an extended range, single engine pusher design.

  5. The prediction of leather mechanical properties from airborne ultrasonic testing of hides

    USDA-ARS?s Scientific Manuscript database

    High quality, clean, and well-preserved hides are paramount for competitiveness in both domestic and export markets. Currently, hides are visually inspected and ranked for quality and sale price, which is not reliable when hair is present on the hides. Advanced technologies are needed to nondestru...

  6. Nonmonetary Compensation in the Public Teacher Labor Market

    ERIC Educational Resources Information Center

    Player, Daniel

    2010-01-01

    Because of the rigid salary structure in the public teacher labor market, principals may have the incentive to align classes favorably for high-quality teachers as a form of nonmonetary compensation. This article tests whether higher-quality teachers, holding other characteristics constant, tend to be matched with more favorable assignments. The…

  7. Evaluation of surface resistivity measurements as an alternative to the rapid chloride permeability test for quality assurance and acceptance : technical summary.

    DOT National Transportation Integrated Search

    2011-07-01

    This project investigated the use of a surface resistivity device as an indication of concretes ability to resist chloride ion penetration for use in quality assurance (QA) and acceptance of high performance concrete (HPC). : The objectives of thi...

  8. Applying Total Quality Management in Cooperative Extension.

    ERIC Educational Resources Information Center

    Fredendall, Lawrence D.; Lippert, Robert M.

    1995-01-01

    South Carolina's Agricultural Service Laboratory received responses from 252 of 500 farmers who currently use the soil testing service; 97% were pleased with accuracy, 89% with turnaround time, 18% thought the fee too high. Nonusers (100 of 520) were mainly dissatisfied with turnaround time. Total quality management methods were used to improve…

  9. 75 FR 59973 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-29

    ...; Cleaning of high precision optics; Stripping; Janitorial cleaning; cleaning of resin, coating, ink, and... laboratories; Cleaning operations in medical device or pharmaceutical manufacturing; and Cleaning operations related to performance or quality assurance testing of coatings, inks, or adhesives. COMAR 26.11.19.09-1...

  10. Quantitative analysis of genomic DNA degradation in whole blood under various storage conditions for molecular diagnostic testing.

    PubMed

    Permenter, Jessalyn; Ishwar, Arjun; Rounsavall, Angie; Smith, Maddie; Faske, Jennifer; Sailey, Charles J; Alfaro, Maria P

    2015-12-01

    Proper storage of whole blood is crucial for isolating nucleic acids from leukocytes and to ensure adequate performance of downstream assays in the molecular diagnostic laboratory. Short-term and long-term storage recommendations are lacking for successful isolation of genomic DNA (gDNA). Container type (EDTA or heparin), temperature (4 °C and room temperature) and time (1-130 days) were assessed as criterion for sample acceptance policies. The percentage of integrated area (%Ti) between 150 and 10,000 bp from the 2200 TapeStation electropherogram was calculated to measure gDNA degradation. Refrigerated EDTA samples yielded gDNA with low %Ti (high quality). Heparinized samples stored at room temperature yielded gDNA of worst quality. Downstream analysis demonstrated that the quality of the gDNA correlated with the quality of the data; samples with high %Ti generated significantly lower levels of high molecular weight amplicons. Recommendations from these analyses include storing blood samples intended for nucleic acid isolation in EDTA tubes at 4 °C for long term storage (>10 days). gDNA should be extracted within 3 days when blood is stored at room temperature regardless of the container. Finally, refrigerated heparinized samples should not be stored longer than 9 days if expecting high quality gDNA isolates. Laboratories should consider many factors, in addition to the results obtained herein, to update their policies for sample acceptance for gDNA extraction intended for molecular genetic testing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. [Comparison on agronomy and quality characters of selective strain of Schizonepeta tenuifolia].

    PubMed

    Cao, Liang; Jin, Yue; Wei, Jianhe; Chu, Qinglong; Zhao, Runhuai; Wang, Weiquan

    2009-05-01

    With the purpose of selecting adequate quality and high production of Schizonepeta tenuifolia, the comparative experiments were carried out on different strain of S. tenuifolia in 2007. The test fields were divided into blocks randomly, and the agronomy characters were investigated in harvest time; the content of volatile oil was measured by steam distillation and the pulegone were determined by HPLC. The yield of S4 was 18.63% and 29.99% higher than that of CK1 and CK2, respectively. The contents of volatile oil and pulegone were also higher than those of CK and other strains in this test. S4 shows the advantages of high production, strong disease resistance and high active components. S4 would be extended as the good breed in production.

  12. Improving visit cycle time using patient flow analysis in a high-volume inner-city hospital-based ambulatory clinic serving minority New Yorkers.

    PubMed

    Dhar, Sanjay; Michel, Raquel; Kanna, Balavenkatesh

    2011-01-01

    Patient waiting time and waiting room congestion are quality indicators that are related to efficiency of ambulatory care systems and patient satisfaction. Our main purpose was to test a program to decrease patient visit cycle time, while maintaining high-quality healthcare in a high-volume inner-city hospital-based clinic in New York City. Use of patient flow analysis and the creation of patient care teams proved useful in identifying areas for improvement, target, and measure effectiveness of interventions. The end result is reduced visit cycle time, improved provider team performance, and sustained patient care outcomes. © 2010 National Association for Healthcare Quality.

  13. JWST Point Spread Function Quality and Stability: Ground Testing, Integrated Modeling, and Space Validation

    NASA Technical Reports Server (NTRS)

    McElwain, Michael; Van Gorkom, Kyle; Bowers, Charles W.; Carnahan, Timothy M.; Kimble, Randy A.; Knight, J. Scott; Lightsey, Paul; Maghami, Peiman G.; Mustelier, David; Niedner, Malcolm B.; hide

    2017-01-01

    The James Webb Space Telescope (JWST) is a large (6.5 m) cryogenic segmented aperture telescope with science instruments that cover the near- and mid-infrared from 0.6-27 microns. The large aperture not only provides high photometric sensitivity, but it also enables high angular resolution across the bandpass, with a diffraction limited point spread function (PSF) at wavelengths longer than 2 microns. The JWST PSF quality and stability are intimately tied to the science capabilities as it is convolved with the astrophysical scene. However, the PSF evolves at a variety of timescales based on telescope jitter and thermal distortion as the observatory attitude is varied. We present the image quality and stability requirements, recent predictions from integrated modeling, measurements made during ground-based testing, and performance characterization activities that will be carried out as part of the commissioning process.

  14. Highly Integrated Quality Assurance – An Empirical Case

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drake Kirkham; Amy Powell; Lucas Rich

    2011-02-01

    Highly Integrated Quality Assurance – An Empirical Case Drake Kirkham1, Amy Powell2, Lucas Rich3 1Quality Manager, Radioisotope Power Systems (RPS) Program, Idaho National Laboratory, P.O. Box 1625 M/S 6122, Idaho Falls, ID 83415-6122 2Quality Engineer, RPS Program, Idaho National Laboratory 3Quality Engineer, RPS Program, Idaho National Laboratory Contact: Voice: (208) 533-7550 Email: Drake.Kirkham@inl.gov Abstract. The Radioisotope Power Systems Program of the Idaho National Laboratory makes an empirical case for a highly integrated Quality Assurance function pertaining to the preparation, assembly, testing, storage and transportation of 238Pu fueled radioisotope thermoelectric generators. Case data represents multiple campaigns including the Pluto/New Horizons mission,more » the Mars Science Laboratory mission in progress, and other related projects. Traditional Quality Assurance models would attempt to reduce cost by minimizing the role of dedicated Quality Assurance personnel in favor of either functional tasking or peer-based implementations. Highly integrated Quality Assurance adds value by placing trained quality inspectors on the production floor side-by-side with nuclear facility operators to enhance team dynamics, reduce inspection wait time, and provide for immediate, independent feedback. Value is also added by maintaining dedicated Quality Engineers to provide for rapid identification and resolution of corrective action, enhanced and expedited supply chain interfaces, improved bonded storage capabilities, and technical resources for requirements management including data package development and Certificates of Inspection. A broad examination of cost-benefit indicates highly integrated Quality Assurance can reduce cost through the mitigation of risk and reducing administrative burden thereby allowing engineers to be engineers, nuclear operators to be nuclear operators, and the cross-functional team to operate more efficiently. Applicability of this case extends to any high-value, long-term project where traceability and accountability are determining factors.« less

  15. Design of bunch compressing system with suppression of coherent synchrotron radiation for ATF upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jing, Yichao; Fedurin, Mikhail; Stratakis, Diktys

    2015-05-03

    One of the operation modes for Accelerator Test Facility (ATF) upgrade is to provide high peak current, high quality electron beam for users. Such operation requires a bunch compressing system with a very large compression ratio. The CSR originating from the strong compressors generally could greatly degrade the quality of the electron beam. In this paper, we present our design for the entire bunch compressing system that will limit the effect of CSR on the e-beam’s quality. We discuss and detail the performance from the start to end simulation of such a compressor for ATF.

  16. Effects of strength training on body composition, physical functioning, and quality of life in prostate cancer patients during androgen deprivation therapy.

    PubMed

    Nilsen, Tormod S; Raastad, Truls; Skovlund, Eva; Courneya, Kerry S; Langberg, Carl W; Lilleby, Wolfgang; Fosså, Sophie D; Thorsen, Lene

    2015-11-01

    Androgen deprivation therapy (ADT) increases survival rates in prostate cancer (PCa) patients with locally advanced disease, but is associated with side effects that may impair daily function. Strength training may counteract several side effects of ADT, such as changes in body composition and physical functioning, which in turn may affect health-related quality of life (HRQOL). However, additional randomised controlled trials are needed to expand this knowledge. Fifty-eight PCa patients on ADT were randomised to either 16 weeks of high-load strength training (n = 28) or usual care (n = 30). The primary outcome was change in total lean body mass (LBM) assessed by dual x-ray absorptiometry (DXA). Secondary outcomes were changes in regional LBM, fat mass, and areal bone mineral density (aBMD) measured by DXA; physical functioning assessed by 1-repetition maximum (1RM) tests, sit-to-stand test, stair climbing test and Shuttle walk test; and HRQOL as measured by the European Organization for the Research and Treatment of Cancer Quality of Life Questionnaire Core 30. No statistically significant effect of high-load strength training was demonstrated on total LBM (p = 0.16), but significant effects were found on LBM in the lower and upper extremities (0.49 kg, p < 0.01 and 0.15 kg, p < 0.05, respectively). Compared to usual care, high-load strength training showed no effect on fat mass, aBMD or HRQOL, but beneficial effects were observed in all 1RM tests, sit-to-stand test and stair climbing tests. Adherence to the training program was 88% for lower body exercises and 84% for upper body exercises. In summary, high-load strength training improved LBM in extremities and physical functioning, but had no effect on fat mass, aBMD, or HRQOL in PCa patients on ADT.

  17. The development of the Pictorial Thai Quality of Life.

    PubMed

    Phattharayuttawat, Sucheera; Ngamthipwatthana, Thienchai; Pitiyawaranun, Buncha

    2005-11-01

    "Quality of life" has become a main focus of interest in medicine. The Pictorial Thai Quality of Life (PTQL) was developed in order to measure the Thai mental illness both in a clinical setting and community. The purpose of this study was to develop the Pictorial Thai Quality of Life (PTQL), having adequate and sufficient construct validity, discriminant power, concurrent validity, and reliability. To develop the Pictorial Thai Quality of Life Test, two samples groups were used in the present study: (1) pilot study samples: 30 samples and (2) survey samples were 672 samples consisting of normal, and psychiatric patients. The developing tests items were collected from a review of the literature in which all the items were based on the WHO definition of Quality of Life. Then, experts judgment by the Delphi technique was used in the first stage. After that a pilot study was used to evaluate the testing administration, and wording of the tests items. The final stage was collected data from the survey samples. The results of the present study showed that the final test was composed 25 items. The construct validity of this test consists of six domains: Physical, Cognitive, Affective, Social Function, Economic and Self-Esteem. All the PTQL items have sufficient discriminant power It was found to be statistically significant different at the. 001 level between those people with mental disorders and normal people. There was a high level of concurrent validity association with WHOQOL-BREF, Pearson correlation coefficient and Area under ROC curve were 0.92 and 0.97 respectively. The reliability coefficients for the Alpha coefficients of the PTQL total test was 0.88. The values of the six scales were from 0.81 to 0:91. The present study was directed at developing an effective psychometric properties pictorial quality of life questionnaire. The result will be a more direct and meaningful application of an instrument to detect the mental health illness poor quality of life in Thai communities.

  18. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa

    PubMed Central

    Jaya, Ziningi; Drain, Paul K.

    2017-01-01

    Introduction Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. Material and methods We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic’s compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor). A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05. Results Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2%) of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics’ average rating score for compliance to the WHO guidelines ranged between 64.4% (CI: 44%– 84%) and 89.2% (CI: 74%– 100%).Ten out of eleven of the clinics were rated as moderate (70–89%). All clinic have scored highest for the following audit component: equipment; process control and specimen management; and facility ad safety, with 100%. Clinics obtained the lowest scores for the assessment audit component followed by process improvement and organisation, with 40.9% (CI: 15.7–66.1%), 45.5% (CI: 10.4–80.5%) and 56.8% (CI: 31.8 81.8%), respectively. A statistically significant correlation was observed between the following: category of staff performing the HIV rapid tests in the audited clinics and service and satisfactory audit component; weekly average number of patients using the audited PHC clinics and service and satisfactory audit component; number of HIV lay counsellors in the audited clinics and quality control audit component with p<0.05. Discussion In the small audit of primary healthcare clinics located within the rural part of KwaZulu-Natal, results revealed an overall moderate rating of the quality management system for rapid HIV testing. Improvements in the organisation, quality control, process improvement and assessment components could enable a higher quality assurance rating for rural HIV testing in KwaZulu-Natal. PMID:28829801

  19. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    PubMed

    Jaya, Ziningi; Drain, Paul K; Mashamba-Thompson, Tivani P

    2017-01-01

    Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor). A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05. Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2%) of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged between 64.4% (CI: 44%- 84%) and 89.2% (CI: 74%- 100%).Ten out of eleven of the clinics were rated as moderate (70-89%). All clinic have scored highest for the following audit component: equipment; process control and specimen management; and facility ad safety, with 100%. Clinics obtained the lowest scores for the assessment audit component followed by process improvement and organisation, with 40.9% (CI: 15.7-66.1%), 45.5% (CI: 10.4-80.5%) and 56.8% (CI: 31.8 81.8%), respectively. A statistically significant correlation was observed between the following: category of staff performing the HIV rapid tests in the audited clinics and service and satisfactory audit component; weekly average number of patients using the audited PHC clinics and service and satisfactory audit component; number of HIV lay counsellors in the audited clinics and quality control audit component with p<0.05. In the small audit of primary healthcare clinics located within the rural part of KwaZulu-Natal, results revealed an overall moderate rating of the quality management system for rapid HIV testing. Improvements in the organisation, quality control, process improvement and assessment components could enable a higher quality assurance rating for rural HIV testing in KwaZulu-Natal.

  20. Synthetic aperture radar signal data compression using block adaptive quantization

    NASA Technical Reports Server (NTRS)

    Kuduvalli, Gopinath; Dutkiewicz, Melanie; Cumming, Ian

    1994-01-01

    This paper describes the design and testing of an on-board SAR signal data compression algorithm for ESA's ENVISAT satellite. The Block Adaptive Quantization (BAQ) algorithm was selected, and optimized for the various operational modes of the ASAR instrument. A flexible BAQ scheme was developed which allows a selection of compression ratio/image quality trade-offs. Test results show the high quality of the SAR images processed from the reconstructed signal data, and the feasibility of on-board implementation using a single ASIC.

  1. Establishment of quality, reliability and design standards for low, medium, and high power microwave hybrid microcircuits

    NASA Technical Reports Server (NTRS)

    Robinson, E. A.

    1973-01-01

    Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.

  2. Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane

    NASA Technical Reports Server (NTRS)

    Gera, Joseph; Bosworth, John T.

    1987-01-01

    This paper describes some novel flight tests and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays. The resulting open-loop and closed-loop frequency responses and the time history comparison using flight and linear simulation data are discussed.

  3. Fabrication and testing of scatter plates for interferometry

    NASA Technical Reports Server (NTRS)

    Pour, J. J., Sr.; Pitts, J. R.

    1972-01-01

    Scatter plate interferometry has become a reliable method of measuring surface configurations of telescope mirrors and other optical components. The scatter plate used in an instrument should be of optimum quality if the surface it is being used to measure is to be of high accuracy. Tests were performed and results show that, although many scatter plates would function, few were of the optimum quality necessary. These few were of the 180 grit group, using 35- and 30-s exposures, which are figures derived from calculations.

  4. Diagnostics in a digital age: an opportunity to strengthen health systems and improve health outcomes.

    PubMed

    Peeling, Rosanna W

    2015-11-01

    Diagnostics play a critical role in clinical decision making, and in disease control and prevention. Rapid point-of-care (POC) tests for infectious diseases can improve access to diagnosis and patient management, but the quality of these tests vary, quality of testing is often not assured and there are few mechanisms to capture test results for surveillance when the testing is so decentralised. A new generation of POC molecular tests that are highly sensitive and specific, robust and easy to use are now available for deployment in low resource settings. Decentralisation of testing outside of the laboratory can put tremendous stress on the healthcare system and presents challenges for training and quality assurance. A feature of many of these POC molecular devices is that they are equipped with data transmission capacities. In a digital age, it is possible to link data from diagnostic laboratories and POC test readers and devices to provide data on testing coverage, disease trends and timely information for early warning of infectious disease outbreaks to inform design or optimisation of disease control and elimination programmes. Data connectivity also allows control programmes to monitor the quality of tests and testing, and optimise supply chain management; thus, increasing the efficiency of healthcare systems and improving patient outcomes. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. An investigation of the effects of pitch-roll (de)coupling on helicopter handling qualities

    NASA Technical Reports Server (NTRS)

    Blanken, C. L.; Pausder, H. J.; Ockier, C. J.

    1995-01-01

    An extensive investigation of the effects of pitch-roll coupling on helicopter handling qualities was performed by the U.S. Army and Deutsche Forschungsanstalt fur Luft- und Raumfahrt (DLR), using a NASA ground-based and a DLR in-flight simulator. Over 90 different coupling configurations were evaluated using a high gain roll-axis tracking task. The results show that although the current ADS-33C coupling criterion discriminates against those types of coupling typical of conventionally controlled helicopters, it is not always suited for the prediction of handling qualities of helicopters with modern control systems. Based on the observation that high frequency inputs during tracking are used to alleviate coupling, a frequency domain pitch-roll coupling criterion that uses the average coupling ratio between the bandwidth and neutral stability frequency is formulated. This criterion provides a more comprehensive coverage with respect to the different types of coupling, shows excellent consistency, and has the additional benefit that compliance testing data are obtained from the bandwidth/phase delay tests, so that no additional flight testing is needed.

  6. Optomechanical design and testing of the VLT tertiary mirrors

    NASA Astrophysics Data System (ADS)

    Bollinger, Wolfgang; Juranek, Hans J.; Schulte, Stefan; May, K.; Michel, Alain

    2000-07-01

    The Tertiary Mirrors for the ESO Very Large Telescope project consist of four optical flats (elliptical, 890 X 1260 mm2). The achieved opto-mechanical design is challenging since it provides high optical overall quality combined with high stiffness (70 Hz Eigenfrequency) and low mass (total mass of 180 kg for the complete unit). Schott (Mainz, Germany) produces the lightweight Zerodur blanks. Carl Zeiss has designed and manufactured the mirror and its support cell. Last not least it became necessary to install the biggest testing equipment for flats in Europe to guarantee for a scientifically correct verification of the quality of the complete unit. All four mirrors have been delivered to ESO.

  7. Experimental Investigation of Reynolds Number Effects on Test Quality in a Hypersonic Expansion Tube

    NASA Astrophysics Data System (ADS)

    Rossmann, Tobias; Devin, Alyssa; Shi, Wen; Verhoog, Charles

    2017-11-01

    Reynolds number effects on test time and the temporal and spatial flow quality in a hypersonic expansion tube are explored using high-speed pressure, infrared optical, and Schlieren imaging measurements. Boundary layer models for shock tube flows are fairly well established to assist in the determination of test time and flow dimensions at typical high enthalpy test conditions. However, the application of these models needs to be more fully explored due to the unsteady expansion of turbulent boundary layers and contact regions separating dissimilar gasses present in expansion tube flows. Additionally, expansion tubes rely on the development of a steady jet with a large enough core-flow region at the exit of the acceleration tube to create a constant velocity region inside of the test section. High-speed measurements of pressure and Mach number at several locations within the expansion tube allow for the determination of an experimental x-t diagram. The comparison of the experimentally determined x-t diagram to theoretical highlights the Reynolds number dependent effects on expansion tube. Additionally, spatially resolved measurements of the Reynolds number dependent, steady core-flow in the expansion tube viewing section are shown. NSF MRI CBET #1531475, Lafayette College, McCutcheon Foundation.

  8. Can Sanitary Surveys Replace Water Quality Testing? Evidence from Kisii, Kenya.

    PubMed

    Misati, Aaron Gichaba; Ogendi, George; Peletz, Rachel; Khush, Ranjiv; Kumpel, Emily

    2017-02-07

    Information about the quality of rural drinking water sources can be used to manage their safety and mitigate risks to health. Sanitary surveys, which are observational checklists to assess hazards present at water sources, are simpler to conduct than microbial tests. We assessed whether sanitary survey results were associated with measured indicator bacteria levels in rural drinking water sources in Kisii Central, Kenya. Overall, thermotolerant coliform (TTC) levels were high: all of the samples from the 20 tested dug wells, almost all (95%) of the samples from the 25 tested springs, and 61% of the samples from the 16 tested rainwater harvesting systems were contaminated with TTC. There were no significant associations between TTC levels and overall sanitary survey scores or their individual components. Contamination by TTC was associated with source type (dug wells and springs were more contaminated than rainwater systems). While sanitary surveys cannot be substituted for microbial water quality results in this context, they could be used to identify potential hazards and contribute to a comprehensive risk management approach.

  9. Errors in clinical laboratories or errors in laboratory medicine?

    PubMed

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes in pre- and post-examination steps must be minimized to guarantee the total quality of laboratory services.

  10. Maternal depression and parenting in early childhood: Contextual influence of marital quality and social support in two samples.

    PubMed

    Taraban, Lindsay; Shaw, Daniel S; Leve, Leslie D; Wilson, Melvin N; Dishion, Thomas J; Natsuaki, Misaki N; Neiderhiser, Jenae M; Reiss, David

    2017-03-01

    Marital quality and social support satisfaction were tested as moderators of the association between maternal depressive symptoms and parenting during early childhood (18-36 months) among 2 large, divergent, longitudinal samples (n = 526; n = 570). Unexpectedly, in both samples the association between maternal depressive symptoms and reduced parenting quality was strongest in the context of high marital quality and high social support, and largely nonsignificant in the context of low marital quality and low social support. Possible explanations for these surprising findings are discussed. Results point to the importance of accounting for factors in the broader family context in predicting the association between depressive symptoms and maternal parenting. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Field testing, refinement, and psychometric evaluation of a new measure of quality of care for assisted living.

    PubMed

    Rantz, Marilyn J; Aud, Myra A; Zwygart-Stauffacher, Mary; Mehr, David R; Petroski, Gregory F; Owen, Steven V; Madsen, Richard W; Flesner, Marcia; Conn, Vicki; Maas, Meridean

    2008-01-01

    Field test results are reported for the Observable Indicators of Nursing Home Care Quality Instrument-Assisted Living Version, an instrument designed to measure the quality of care in assisted living facilities after a brief 30-minute walk-through. The OIQ-AL was tested in 207 assisted-living facilities in two states using classical test theory, generalizability theory, and exploratory factor analysis. The 34-item scale has a coherent six-factor structure that conceptually describes the multidimensional concept of care quality in assisted living. The six factors can be logically clustered into process (Homelike and Caring, 21 items) and structure (Access and Choice; Lighting; Plants and Pets; Outdoor Spaces) subscales and for a total quality score. Classical test theory results indicate most subscales and the total quality score from the OIQ-AL have acceptable interrater, test-retest, and strong internal consistency reliabilities. Generalizability theory analyses reveal that dependability of scores from the instrument are strong, particularly by including a second observer who conducts a site visit and independently completes an instrument, or by a single observer conducting two site visits and completing instruments during each visit. Scoring guidelines based on the total sample of observations (N = 358) help guide those who want to use the measure to interpret both subscale and total scores. Content validity was supported by two expert panels of people experienced in the assisted-living field, and a content validity index calculated for the first version of the scale is high (3.43 on a four-point scale). The OIQ-AL gives reliable and valid scores for researchers, and may be useful for consumers, providers, and others interested in measuring quality of care in assisted-living facilities.

  12. Water Quality Improvement of Media Culture for Tilapia (Oreochromis niloticus) with Cleaner Production Method

    NASA Astrophysics Data System (ADS)

    Haeruddin; Supriharyono; Febrianto, S.

    2018-02-01

    The tilapia (Oreochromis niloticus), is known as a high adaptability and brackish water tolerance fish. This fish is also has a meat with high protein content, that ranges about 65 -75%. Generally the tilapia is cultured using a conventional system with high density. It is caused degradation of water quality of media culture, and finally increase mortality rate of fish cultured. The application of tilapia cultivation with cleaner production method by giving enzyme into the feed to upgrade the efficiency of feed utilization, presumed that could improve the water quality of cultivation media. It is due to the lower of feed and feces residues. Therefore the concentration of toxic compounds, such as ammonia, nitrite and sulfide, will be lower. The experiments were conducted for 35 days with a completely factorial randomized design. The first factor was the dosage of enzyme in the feed, consisting of 4 dosages, and the second factor was the duration of the test fish maintenance (5 weeks). Water quality variables examined included ammonia, nitrite and sulfide. The results showed that enzyme dosage had no significantly impact on ammonia, nitrite and sulfide concentrations in the test media culture. However, the feeding with enzyme in low dosage, resulted less concentration of ammonia, nitrite and sulfide than it was without enzyme). The duration of fish cultured has significantly effect on the concentration of ammonia, nitrite and sulfide in the test media. While it is no significantly correlation between dosage and duration of maintenance.

  13. How I do it: feasibility of a new ultrasound probe fixator to facilitate high quality stress echocardiography.

    PubMed

    Salden, O A E; van Everdingen, W M; Spee, R; Doevendans, P A; Cramer, M J

    2018-03-27

    Stress echocardiography (SE) has recently regained momentum as an important diagnostic tool for the assessment of both ischemic and non-ischemic heart disease. Performing SE during physical exercise is challenging due to a suboptimal patient position and vigorous movements of the patient's chest. This hampers a stable ultrasound position and reduces the diagnostic performance of SE. A stable ultrasound probe position would facilitate producing high quality images during continuous measurements. With Probefix (Usono, Eindhoven, The Netherlands), a newly developed tool to fixate the ultrasound probe to the patient's chest, stabilization of the probe during physical exercise is possible. The technique of SE with the Probefix and its' feasibility are evaluated in a small pilot study. Probefix fixates the ultrasound probe to the patient's chest, using two chest straps and a fixation device. The ultrasound probe position and angle may be altered with a relative high degree of freedom. We tested the Probefix for continuous echocardiographic imaging in 12 study subjects during supine and upright ergometer stress tests. One patient was unable to perform exercise and in two study subjects good quality images were not achieved. In the other patients (82%) a stable probe position was obtained, with subsequent good quality echocardiographic images during SE. We have demonstrated the feasibility of the Probefix support during ergometer tests in supine and upright positions and conclude that this external fixator may facilitate continuous monitoring of cardiac function in a group of patients.

  14. Rapid and specific drug quality testing assay for artemisinin and its derivatives using a luminescent reaction and novel microfluidic technology.

    PubMed

    Ho, Nga T; Desai, Darash; Zaman, Muhammad H

    2015-06-01

    Globally, it is estimated that about 10-30% of pharmaceuticals are of poor quality. Poor-quality drugs lead to long-term drug resistance, create morbidity, and strain the financial structure of the health system. The current technologies for substandard drug detection either are too expensive for low-resource regions or only provide qualitative results. To address the current limitations with point-of-care technologies, we have developed an affordable and robust assay to quantify the amount of active pharmaceutical ingredients (APIs) to test product quality. Our novel assay consists of two parts: detection reagent (probe) and a microfluidic testing platform. As antimalarials are of high importance in the global fight against malaria and are often substandard, they are chosen as the model to validate our assay. As a proof-of-concept, we have tested the assay with artesunate pure and substandard samples (Arsuamoon tablets) from Africa and compared with the conventional 96-well plate with spectrophotometer to demonstrate the quantitative efficacy and performance of our system. © The American Society of Tropical Medicine and Hygiene.

  15. Cholinesterase inhibitors for rarer dementias associated with neurological conditions.

    PubMed

    Li, Ying; Hai, Shan; Zhou, Yan; Dong, Bi Rong

    2015-03-03

    Rarer dementias include Huntington's disease (HD), cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL), frontotemporal dementia (FTD), dementia in multiple sclerosis (MS) and progressive supranuclear palsy (PSP). Cholinesterase inhibitors, including donepezil, galantamine and rivastigmine, are considered to be the first-line medicines for Alzheimer's disease and some other dementias, such as dementia in Parkinson's disease. Cholinesterase inhibitors are hypothesised to work by inhibiting the enzyme acetylcholinesterase (AChE) which breaks down the neurotransmitter acetylcholine. Cholinesterase inhibitors may also lead to clinical improvement for rarer dementias associated with neurological conditions. To assess the efficacy and safety of cholinesterase inhibitors for cognitive impairment or dementia associated with neurological conditions. We searched the Cochrane Dementia and Cognitive Improvement Group's Specialised Register, CENTRAL, MEDLINE, EMBASE, PsycINFO, CINAHL, LILACS, several trial registries and grey literature sources in August 2013. We included randomised, double-blind, controlled trials assessing the efficacy of treatment of rarer dementias associated with neurological conditions with currently marketed cholinesterase inhibitors. Two review authors independently assessed eligibility and quality of trials, and extracted data. We used the standard methodological procedures of the Cochrane Collaboration. We included eight RCTs involving 567 participants. Six studies used a simple parallel-group design; the other two consisted of an open-label treatment period followed by a randomised phase. All trials were well concealed for allocation and double-blind, however the sample sizes of most trials were small. All trials used placebo as control. We performed meta-analyses for some outcomes in patients with MS. For all other conditions, results are presented narratively.Two trials included patients with HD; one found that cholinesterase inhibitor use in the short-term had no statistically significant impact on the cognitive portion of the Alzheimer Disease Assessment Scale (ADAS-Cog; 1 study, WMD 1.00, 95% CI -1.66 to 3.66, P = 0.46; low quality evidence), Unified Huntington's Disease Rating Scale (UHDRS) Verbal Fluency Test (1 study, WMD -1.20, 95% CI -7.97 to 5.57, P = 0.73; low quality evidence), UHDRS Symbol Digit Modalities Test (SDMT; 1 study, WMD 2.70, 95% CI -0.95 to 6.35, P = 0.15; low quality evidence) and other psychometric tests. The other study found that cholinesterase inhibitor use in the medium-term improved the results of the verbal fluency test (1 study, WMD 6.43, 95% CI 0.66 to 12.20, P = 0.03; moderate quality evidence) and California Verbal Learning Test - Second Edition (CVLT-II) Recognition Task (1 study, WMD 2.42, 95% CI 0.17 to 4.67, P = 0.04; moderate quality evidence). There was no statistically significant difference between groups on the SDMT (1 study, WMD -0.31, 95% CI -7.77 to 7.15, P = 0.94; moderate quality evidence), CVLT-II trials 1-5 (1 study, WMD -2.09, 95% CI -11.65 to 7.47, P = 0.67; moderate quality evidence), short-delay recall (1 study, WMD 0.35, 95% CI -2.87 to 3.57, P = 0.83; moderate quality evidence), or long-delay recall (1 study, WMD -0.14, 95% CI -3.08 to 2.80, P = 0.93; moderate quality evidence), and other psychometric tests.Four trials included patients with MS; one found no differences between the cholinesterase inhibitors (short-term) and placebo groups on the Wechsler Memory Scales general memory score (1 study, WMD 0.90, 95% CI -0.52 to 2.32, P = 0.22; low quality evidence). The three other trials found that, in the medium-term - cholinesterase inhibitors improved the clinician's impression of cognitive change (2 studies, OR 1.96, 95% CI 1.06 to 3.62, P = 0.03; high quality evidence). However, the treatment effect on other aspects of cognitive change were unclear, measured by the Selective Reminding Test (3 studies, WMD 1.47, 95% CI -0.39 to 3.32, P = 0.12; high quality evidence), patient's self-reported impression of memory change (2 studies, OR 1.67, 95% CI 0.93 to 3.00, P = 0.08; high quality evidence) and cognitive change (1 study, OR 0.95, 95% CI 0.45 to 1.98, P = 0.89; high quality evidence), clinician's impression of memory change (1 study, OR 1.50, 95% CI 0.59 to 3.84, P = 0.39; moderate quality evidence), other psychometric tests, and activities of daily living - patient reported impact of multiple sclerosis activities (1 study, WMD -1.18, 95% CI -3.02 to 0.66, P = 0.21; low quality evidence).One study on patients with CADASIL found a beneficial effect of cholinesterase inhibitors on the Executive interview, and Trail Making Test parts A and B. The impact of cholinesterase inhibitors on the Vascular ADAS-Cog score (1 study, WMD 0.04, 95% CI -1.57 to 1.65, P = 0.96; high quality evidence), the Clinical Dementia Rating Scale Sum of Boxes (1 study, WMD -0.09, 95% CI -0.48 to 0.03, P = 0.65; high quality evidence) Disability Assessment for Dementia scale (1 study, WMD 0.58, 95% CI -2.72 to 3.88, P = 0.73; moderate quality evidence), and other measures was unclearOne study included patients with FTD. This trial consisted of an open-label treatment period followed by a randomised, double-blind, placebo-controlled phase. No data of primary outcomes were reported in this study.In the included studies, the most common side effect was gastrointestinal symptoms. For all conditions, compared to the treatment group, the placebo group experienced significantly less nausea (6 studies, 44/257 vs. 22/246, OR 2.10, 95% CI 1.22 to 3.62, P = 0.007; high quality evidence), diarrhoea (6 studies, 40/257 vs. 13/246, OR 3.26, 95% CI 1.72 to 6.19, P = 0.0003; moderate quality evidence) and vomiting (3 studies, 17/192 vs. 3/182, OR 5.76, 95% CI 1.67 to 19.87, P = 0.006; moderate quality evidence). The sample sizes of most included trials were small, and some of the results were extracted from only one study. There were no poolable data for HD, CADASIL and FTD patients and there were no results for patients with PSP. Current evidence shows that the efficacy on cognitive function and activities of daily living of cholinesterase inhibitors in people with HD, CADASIL, MS, PSP or FTD is unclear, although cholinesterase inhibitors are associated with more gastrointestinal side effects compared with placebo.

  16. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    PubMed

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Effects of high-temperature pressure cooking and traditional cooking on soymilk: Protein particles formation and sensory quality.

    PubMed

    Zuo, Feng; Peng, Xingyun; Shi, Xiaodi; Guo, Shuntang

    2016-10-15

    This study focused on the effect of high-temperature pressure cooking on the sensory quality of soymilk. Soymilk was prepared by high-temperature pressure cooking (105-125°C and 0.12-0.235MPa) and traditional cooking (97°C and 0.1MPa). The size distribution and composition of protein particles and the rheological properties of soymilk were compared. Results showed that the content of protein particles and the average size of soymilk particles were higher in high-temperature pressure cooking than in traditional cooking (p<0.05). High-temperature pressure cooking affected soymilk protein denaturation and favored protein aggregation. Similar to traditional soymilk, soymilk cooked at 115°C was categorized as a Newtonian fluid but was found with increased viscosity in the rheological test. Soymilk cooked at 115°C for 10min exhibited a homogeneous, smooth, and creamy texture with a high acceptability in the sensory test. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The Global Testing Culture: Shaping Education Policy, Perceptions, and Practice. Oxford Studies in Comparative Education

    ERIC Educational Resources Information Center

    Smith, William C., Ed.

    2016-01-01

    The past thirty years have seen a rapid expansion of testing, exposing students worldwide to tests that are now, more than ever, standardized and linked to high-stakes outcomes. The use of testing as a policy tool has been legitimized within international educational development to measure education quality in the vast majority of countries…

  19. Development and implementation of an automatic integration system for fibre optic sensors in the braiding process with the objective of online-monitoring of composite structures

    NASA Astrophysics Data System (ADS)

    Hufenbach, W.; Gude, M.; Czulak, A.; Kretschmann, Martin

    2014-04-01

    Increasing economic, political and ecological pressure leads to steadily rising percentage of modern processing and manufacturing processes for fibre reinforced polymers in industrial batch production. Component weights beneath a level achievable by classic construction materials, which lead to a reduced energy and cost balance during product lifetime, justify the higher fabrication costs. However, complex quality control and failure prediction slow down the substitution by composite materials. High-resolution fibre-optic sensors (FOS), due their low diameter, high measuring point density and simple handling, show a high applicability potential for an automated sensor-integration in manufacturing processes, and therefore the online monitoring of composite products manufactured in industrial scale. Integrated sensors can be used to monitor manufacturing processes, part tests as well as the component structure during product life cycle, which simplifies allows quality control during production and the optimization of single manufacturing processes.[1;2] Furthermore, detailed failure analyses lead to a enhanced understanding of failure processes appearing in composite materials. This leads to a lower wastrel number and products of a higher value and longer product life cycle, whereby costs, material and energy are saved. This work shows an automation approach for FOS-integration in the braiding process. For that purpose a braiding wheel has been supplemented with an appliance for automatic sensor application, which has been used to manufacture preforms of high-pressure composite vessels with FOS-networks integrated between the fibre layers. All following manufacturing processes (vacuum infiltration, curing) and component tests (quasi-static pressure test, programmed delamination) were monitored with the help of the integrated sensor networks. Keywords: SHM, high-pressure composite vessel, braiding, automated sensor integration, pressure test, quality control, optic-fibre sensors, Rayleigh, Luna Technologies

  20. Stability of fruit quality traits in diverse watermelon cultivars tested in multiple environments

    PubMed Central

    Dia, Mahendra; Wehner, Todd C; Perkins-Veazie, Penelope; Hassell, Richard; Price, Daniel S; Boyhan, George E; Olson, Stephen M; King, Stephen R; Davis, Angela R; Tolla, Gregory E; Bernier, Jerome; Juarez, Benito

    2016-01-01

    Lycopene is a naturally occurring red carotenoid compound that is found in watermelon. Lycopene has antioxidant properties. Lycopene content, sugar content and hollowheart resistance are subject to significant genotype×environment interaction (G×E), which makes breeding for these fruit quality traits difficult. The objectives of this study were to (i) evaluate the influence of years and locations on lycopene content, sugar content and hollowheart resistance for a set of watermelon genotypes, and (ii) identify genotypes with high stability for lycopene, sugar, and hollowheart resistance. A diverse set of 40 genotypes was tested over 3 years and 8 locations across the southern United States in replicated, multi-harvest trials. Lycopene was tested in a subset of 10 genotypes. Data were analyzed using univariate and multivariate stability statistics (BLUP-GGE biplot) using SASGxE and RGxE programs. There were strong effects of environment as well as G×E interaction on watermelon quality traits. On the basis of stability measures, genotypes were classified as stable or unstable for each quality trait. 'Crimson Sweet' is an inbred line with high quality trait performance as well as trait stability. 'Stone Mountain', 'Tom Watson', 'Crimson Sweet' and 'Minilee' were among the best genotypes for lycopene content, sugar content and hollowheart resistance. We developed a stability chart based on marketable yield and average ranking generated from different stability measures for yield attributes and quality traits. The chart will assist in choosing parents for improvement of watermelon cultivars. See http://cuke.hort.ncsu.edu/cucurbit/wmelon/wmelonmain.html. PMID:28066557

  1. Laboratory Innovation Towards Quality Program Sustainability.

    PubMed

    Abimiku, Alash'le; Timperi, Ralph; Blattner, William

    2016-08-01

    Laboratory innovation significantly affects program sustainability of HIV programs in low and middle income countries (LMICs) far beyond its immediate sphere of impact. Innovation in rapid development of diagnostic technologies, improved quality management systems, strengthened laboratory management, affordable external quality assurance and accreditation schemes, and building local capacity have reduced costs, brought quality improvement to point-of-care testing, increased access to testing services, reduced treatment and prevention costs and opened the door to the real possibility of ending the AIDS epidemic. However, for effectively implemented laboratory innovation to contribute to HIV quality program sustainability, it must be implemented within the overall context of the national strategic plan and HIV treatment programs. The high quality of HIV rapid diagnostic test was a breakthrough that made it possible for more persons to learn their HIV status, receive counseling, and if infected to receive treatment. Likewise, the use of dried blood spots made the shipment of samples easier for the assessment of different variables of HIV infection-molecular diagnosis, CD4+ cell counts, HIV antibodies, drug resistance surveillance, and even antiretroviral drug level measurements. Such advancement is critical for to reaching the UNAIDS target of 90-90-90 and for bringing the AIDS epidemic to an end, especially in LMICs.

  2. Examples of subjective image quality enhancement in multimedia

    NASA Astrophysics Data System (ADS)

    Klíma, Miloš; Pazderák, Jiří; Fliegel, Karel

    2007-09-01

    The subjective image quality is an important issue in all multimedia imaging systems with a significant impact onto QoS (Quality of Service). For long time the image fidelity criterion was widely applied in technical systems esp. in both television and image source compression fields but the optimization of subjective perception quality and fidelity approach (such as the minimum of MSE) are very different. The paper presents an experimental testing of three different digital techniques for the subjective image quality enhancement - color saturation, edge enhancement, denoising operators and noise addition - well known from both the digital photography and video. The evaluation has been done for extensive operator parameterization and the results are summarized and discussed. It has been demonstrated that there are relevant types of image corrections improving to some extent the subjective perception of the image. The above mentioned techniques have been tested for five image tests with significantly different image characteristics (fine details, large saturated color areas, high color contrast, easy-to-remember colors etc.). The experimental results show the way to optimized use of image enhancing operators. Finally the concept of impressiveness as a new possible expression of subjective quality improvement is presented and discussed.

  3. Evaluation of the performance of a micromethod for measuring urinary iodine by using six sigma quality metrics.

    PubMed

    Hussain, Husniza; Khalid, Norhayati Mustafa; Selamat, Rusidah; Wan Nazaimoon, Wan Mohamud

    2013-09-01

    The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TEas) set by two external quality assurance (EQA) providers. UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TEas showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TEcalc)

  4. Sex-specific effect of juvenile diet on adult disease resistance in a field cricket.

    PubMed

    Kelly, Clint D; Tawes, Brittany R

    2013-01-01

    Food limitation is expected to reduce an individual's body condition (body mass scaled to body size) and cause a trade-off between growth and other fitness-related traits, such as immunity. We tested the condition-dependence of growth and disease resistance in male and female Gryllus texensis field crickets by manipulating diet quality via nutrient content for their entire life and then subjecting individuals to a host resistance test using the live bacterium Serratia marcescens. As predicted, crickets on a high-quality diet eclosed more quickly, and at a larger body size and mass. Crickets on a high-quality diet were not in better condition at the time of eclosion, but they were in better condition 7-11 days after eclosion, with females also being in better condition than males. Despite being in better condition, however, females provided with a high-quality diet had significantly poorer disease resistance than females on a low-quality diet and in poor condition. Similarly, males on low- and high-quality diets did not differ in their disease resistance, despite differing in their body condition. A sex difference in disease resistance under diet-restriction suggests that females might allocate resources toward immunity during development if they expect harsh environmental conditions as an adult or it might suggest that females allocate resources toward other life history activities (i.e. reproduction) when food availability increases. We do not know what immune effectors were altered under diet-restriction to increase disease resistance, but our findings suggest that increased immune function might provide an explanation for the sexually-dimorphic increase in longevity generally observed in diet-restricted animals.

  5. Genotypic and environmental effects on cottonseed oil, nitrogen, and gossypol contents in eighteen years Regional High Quality tests

    USDA-ARS?s Scientific Manuscript database

    Determination of environmental influence on seed traits is critical for genetic improvement of seed quality in Upland cotton (Gossypium hirsutum L.). The objective of this study was to analyze the relative contribution of environment and genotype (G) for seed oil, nitrogen (N), and gossypol content...

  6. Hydrodynamic pressure processing: Impact on the quality attributes of fresh and further-processed meat products

    USDA-ARS?s Scientific Manuscript database

    This book chapter reviews hydrodynamic pressure processing (HDP) as an innovative, postharvest technology for enhancing the quality attributes of fresh and further-processed meat products. A variety of meat products have been tested for their response to the high pressure shockwaves of HDP. The st...

  7. Automated water monitor system field demonstration test report. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.

    1981-01-01

    A system that performs water quality monitoring on-line and in real time much as it would be done in a spacecraft, was developed and demonstrated. The system has the capability to determine conformance to high effluent quality standards and to increase the potential for reclamation and reuse of water.

  8. Software Quality Control at Belle II

    NASA Astrophysics Data System (ADS)

    Ritter, M.; Kuhr, T.; Hauth, T.; Gebard, T.; Kristof, M.; Pulvermacher, C.; Belle Software Group, II

    2017-10-01

    Over the last seven years the software stack of the next generation B factory experiment Belle II has grown to over one million lines of C++ and Python code, counting only the part included in offline software releases. There are several thousand commits to the central repository by about 100 individual developers per year. To keep a coherent software stack of high quality that it can be sustained and used efficiently for data acquisition, simulation, reconstruction, and analysis over the lifetime of the Belle II experiment is a challenge. A set of tools is employed to monitor the quality of the software and provide fast feedback to the developers. They are integrated in a machinery that is controlled by a buildbot master and automates the quality checks. The tools include different compilers, cppcheck, the clang static analyzer, valgrind memcheck, doxygen, a geometry overlap checker, a check for missing or extra library links, unit tests, steering file level tests, a sophisticated high-level validation suite, and an issue tracker. The technological development infrastructure is complemented by organizational means to coordinate the development.

  9. Use of ocean color scanner data in water quality mapping

    NASA Technical Reports Server (NTRS)

    Khorram, S.

    1981-01-01

    Remotely sensed data, in combination with in situ data, are used in assessing water quality parameters within the San Francisco Bay-Delta. The parameters include suspended solids, chlorophyll, and turbidity. Regression models are developed between each of the water quality parameter measurements and the Ocean Color Scanner (OCS) data. The models are then extended to the entire study area for mapping water quality parameters. The results include a series of color-coded maps, each pertaining to one of the water quality parameters, and the statistical analysis of the OCS data and regression models. It is found that concurrently collected OCS data and surface truth measurements are highly useful in mapping the selected water quality parameters and locating areas having relatively high biological activity. In addition, it is found to be virtually impossible, at least within this test site, to locate such areas on U-2 color and color-infrared photography.

  10. Diagnostic accuracy of clinical tests of the hip: a systematic review with meta-analysis.

    PubMed

    Reiman, Michael P; Goode, Adam P; Hegedus, Eric J; Cook, Chad E; Wright, Alexis A

    2013-09-01

    Hip Physical Examination (HPE) tests have long been used to diagnose a myriad of intra-and extra-articular pathologies of the hip joint. Useful clinical utility is necessary to support diagnostic imaging and subsequent surgical decision making. Summarise and evaluate the current research and utility on the diagnostic accuracy of HPE tests for the hip joint germane to sports related injuries and pathology. A computer-assisted literature search of MEDLINE, CINHAL and EMBASE databases (January 1966 to January 2012) using keywords related to diagnostic accuracy of the hip joint. This systematic review with meta-analysis utilised the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for the search and reporting phases of the study. Der-Simonian and Laird random effects models were used to summarise sensitivities (SN), specificities (SP), likelihood ratios and diagnostic OR. The employed search strategy revealed 25 potential articles, with 10 demonstrating high quality. Fourteen articles qualified for meta-analysis. The meta-analysis demonstrated that most tests possess weak diagnostic properties with the exception of the patellar-pubic percussion test, which had excellent pooled SN 95 (95% CI 92 to 97%) and good specificity 86 (95% CI 78 to 92%). Several studies have investigated pathology in the hip. Few of the current studies are of substantial quality to dictate clinical decision-making. Currently, only the patellar-pubic percussion test is supported by the data as a stand-alone HPE test. Further studies involving high quality designs are needed to fully assess the value of HPE tests for patients with intra- and extra-articular hip dysfunction.

  11. The comparison of rapid bioassays for the assessment of urban groundwater quality.

    PubMed

    Dewhurst, R E; Wheeler, J R; Chummun, K S; Mather, J D; Callaghan, A; Crane, M

    2002-05-01

    Groundwater is a complex mixture of chemicals that is naturally variable. Current legislation in the UK requires that groundwater quality and the degree of contamination are assessed using chemical methods. Such methods do not consider the synergistic or antagonistic interactions that may affect the bioavailability and toxicity of pollutants in the environment. Bioassays are a method for assessing the toxic impact of whole groundwater samples on the environment. Three rapid bioassays, Eclox, Microtox and ToxAlert, and a Daphnia magna 48-h immobilisation test were used to assess groundwater quality from sites with a wide range of historical uses. Eclox responses indicated that the test was very sensitive to changes in groundwater chemistry; 77% of the results had a percentage inhibition greater than 90%. ToxAlert, although suitable for monitoring changes in water quality under laboratory conditions, produced highly variable results due to fluctuations in temperature and the chemical composition of the samples. Microtox produced replicable results that correlated with those from D. magna tests.

  12. Handling Qualities of Model Reference Adaptive Controllers with Varying Complexity for Pitch-Roll Coupled Failures

    NASA Technical Reports Server (NTRS)

    Schaefer, Jacob; Hanson, Curt; Johnson, Marcus A.; Nguyen, Nhan

    2011-01-01

    Three model reference adaptive controllers (MRAC) with varying levels of complexity were evaluated on a high performance jet aircraft and compared along with a baseline nonlinear dynamic inversion controller. The handling qualities and performance of the controllers were examined during failure conditions that induce coupling between the pitch and roll axes. Results from flight tests showed with a roll to pitch input coupling failure, the handling qualities went from Level 2 with the baseline controller to Level 1 with the most complex MRAC tested. A failure scenario with the left stabilator frozen also showed improvement with the MRAC. Improvement in performance and handling qualities was generally seen as complexity was incrementally added; however, added complexity usually corresponds to increased verification and validation effort required for certification. The tradeoff between complexity and performance is thus important to a controls system designer when implementing an adaptive controller on an aircraft. This paper investigates this relation through flight testing of several controllers of vary complexity.

  13. Selection indices for quality evaluation in wheat breeding.

    PubMed

    Branlard, G; Pierre, J; Rousset, M

    1992-06-01

    From multilocation trials involving 125 cultivars of wheat of mainly French and European origin four tests - protein content, Pelshenke, modified Zeleny and the mixograph - were used to establish six selection indices. Three of these indices - IW1, IW2 and IW3 - were calculated in order to evaluate the genetic potentiality of the lines for dough strength as given by the Chopin alveograph. The indices IV1, IV2 and IV3 were established to evaluate loaf volume as measured by the French bread-making standard. A quality index IQ was calculated from the allelic effects of the high-molecular-weight (HMW) subunits of glutenin from 195 cultivars assessed by the Chopin alveograph and the Pelshenke test. Comparison of the relative efficiency of each of the six indices to the individual tests revealed the superiority of the indices over one or several technological parameters. The six selection indices and the quality index were compared using 30 very diverse F4 lines. Their ability to retain the good quality lines is discussed in particular.

  14. Rupture testing for the quality control of electrodeposited copper interconnections in high-speed, high-density circuits

    NASA Technical Reports Server (NTRS)

    Zakraysek, Louis

    1987-01-01

    Printed Wiring Multilayer Board (PWMLB) structures for high speed, high density circuits are prone to failure due to the microcracking of electrolytic copper interconnections. The failure can occur in the foil that makes up the inner layer traces or in the plated through holes (PTH) deposit that forms the layer to layer interconnections. It is shown that there are some distinctive differences in the quality of Type E copper and that these differences can be detected before its use in a PWMLB. It is suggested that the strength of some Type E copper can be very low when the material is hot and that it is the use of this poor quality material in a PWMLB that results in PTH and inner layer microcracking. Since the PWMLB failure in question are induced by a thermal stress, and since the poorer grades of Type E materials used in these structures are susceptible to premature failure under thermal stress, the use of elevated temperature rupture and creep rupture testing is proposed as a means for screening copper foil, or its PTH equivalent, in order to eliminate the problem of Type E copper microcracking in advanced PWMLBs.

  15. Resistance Spot Welding Characteristics and High Cycle Fatigue Behavior of DP 780 Steel Sheet

    NASA Astrophysics Data System (ADS)

    Pal, Tapan Kumar; Bhowmick, Kaushik

    2012-02-01

    Resistance spot welding characteristics of DP 780 steel was investigated using peel test, microhardness test, tensile shear test, and fatigue test. Tensile shear test provides better spot weld quality than conventional peel test and hardness is not a good indicator of the susceptibility to interfacial fracture. The results of high-cycle fatigue behavior of spot welded DP 780 steel under two different parameters show that at high load low cycle range a significant difference in the S- N curve and almost similar fatigue behavior of spot welds at low load high cycle range are obtained. However, when applied load was converted to stress intensity factor, the difference in the fatigue behavior between welds diminished. Furthermore, a transition in fracture mode, i.e., interfacial and plug and hole-type at about 50% of yield load is observed.

  16. Research on the Effect of Welding Speed on the Quality of Welding Seam Based on the Local Dry Underwater Welding

    NASA Astrophysics Data System (ADS)

    Liu, Lei; Chen, Wu; Wang, Huagang; Ba, Jinyu; Li, Bing

    2017-12-01

    The repair of nuclear spent fuel pool has a high requirement for the quality of welding, the welding speed directly affects the quality of the weld when local dry automatic underwater welding is used to repair the damaged surface. Under the condition of the same condition, the local dry automatic underwater welding test was carried out under the condition of the same welding condition. Taking the 20cm as the experimental condition, after massive experiments show that when the welding speed is approximately 48cm/min the weld quality is high, meeting the design requirements, based on the double layer shrinkage nozzle chamber of local dry underwater automatic welding.

  17. Modernized build and test infrastructure for control software at ESO: highly flexible building, testing, and automatic quality practices for telescope control software

    NASA Astrophysics Data System (ADS)

    Pellegrin, F.; Jeram, B.; Haucke, J.; Feyrin, S.

    2016-07-01

    The paper describes the introduction of a new automatized build and test infrastructure, based on the open-source software Jenkins1, into the ESO Very Large Telescope control software to replace the preexisting in-house solution. A brief introduction to software quality practices is given, a description of the previous solution, the limitations of it and new upcoming requirements. Modifications required to adapt the new system are described, how these were implemented to current software and the results obtained. An overview on how the new system may be used in future projects is also presented.

  18. [Drug information for patients (Package Leaflets), and user testing in EU].

    PubMed

    Yamamoto, Michiko; Doi, Hirohisa; Furukawa, Aya

    2015-01-01

    Patients and consumers have desired high quality drug information in their pharmacotherapy, and are entitled to receive it. It is desirable that the information should be aimed at shared decision-making between patients and healthcare professionals about medications. The quality of drug information available to patients should also be assured. With an aim to improve the quality of "Drug Guide for Patients", we investigated Patient Information Leaflets (PILs) which are approved by the Medicines and Healthcare Products Regulatory Agency (MHRA) in the United Kingdom (UK) with regard to the criteria of development and user testing for assuring the quality of the PILs. In the European Union (EU), these are called Package Leaflets (PLs). PILs have been a legal requirement in the UK since 1999 for all medications. The user testing of PILs has been implemented as evidence since 2005 so that people can rely on the information provided in the leaflet. Execution of PILs which follow the guidance of the user testing, according to the guidance of this user testing, would reflect the views of patients. Here, we introduce the development process and implementation of user testing of PILs. In terms of readability, accessibility and understandability of drug information for patients, we need to discuss involving the public in decisions on how its quality should be assured and how it can be made easily be comprehensible for patients, in order to make effective use of "Drug Guide for Patients" in the future in Japan.

  19. 34 CFR 200.56 - Definition of “highly qualified teacher.”

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... areas of the basic elementary school curriculum; or (3) At the public middle and high school levels, demonstrate a high level of competency by— (i) Passing a rigorous State test in each academic subject in which... teacher— (1) Receives high-quality professional development that is sustained, intensive, and classroom...

  20. 34 CFR 200.56 - Definition of “highly qualified teacher.”

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... areas of the basic elementary school curriculum; or (3) At the public middle and high school levels, demonstrate a high level of competency by— (i) Passing a rigorous State test in each academic subject in which... teacher— (1) Receives high-quality professional development that is sustained, intensive, and classroom...

  1. 34 CFR 200.56 - Definition of “highly qualified teacher.”

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... areas of the basic elementary school curriculum; or (3) At the public middle and high school levels, demonstrate a high level of competency by— (i) Passing a rigorous State test in each academic subject in which... teacher— (1) Receives high-quality professional development that is sustained, intensive, and classroom...

  2. 34 CFR 200.56 - Definition of “highly qualified teacher.”

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... areas of the basic elementary school curriculum; or (3) At the public middle and high school levels, demonstrate a high level of competency by— (i) Passing a rigorous State test in each academic subject in which... teacher— (1) Receives high-quality professional development that is sustained, intensive, and classroom...

  3. 34 CFR 200.56 - Definition of “highly qualified teacher.”

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... areas of the basic elementary school curriculum; or (3) At the public middle and high school levels, demonstrate a high level of competency by— (i) Passing a rigorous State test in each academic subject in which... teacher— (1) Receives high-quality professional development that is sustained, intensive, and classroom...

  4. Assessment of the quality of simvastatin capsules from compounding pharmacies.

    PubMed

    Markman, Blanca Elena Ortega; Rosa, Paulo César Pires; Koschtschak, Maria Regina Walter

    2010-12-01

    To validate a method for determining the simvastatin content of compounded capsules, using high performance liquid chromatography. Eighteen samples of simvastatin 40 mg capsules from compounding pharmacies in the cities of São Paulo, Guarulhos, São Bernardo do Campo and Campinas, Southeastern Brazil, prescribed for fictitious patients were assessed. The analyses were based on the Brazilian Pharmacopoeia and on the high performance liquid chromatography method, optimized and validated in accordance with national and international standards for identification and quantification tests on compounded capsules. The mean weight of the capsules ranged from 70 mg to 316 mg; four samples presented weight variation outside of the specification. The simvastatin content in the capsules was within the specification in 11 samples. In six, the content ranged from 4% to 87% of the declared quantity, thereby not complying with the content requirements for the active agent. For one sample, no content or uniformity determinations were performed. In the content uniformity test, 15 samples presented indices of less than 85%, with relative standard deviations greater than 6%. Three pharmacies had met the specification in this test. In the dissolution test, eight samples presented unsatisfactory results in the first stage of the test, while the remainder presented inconclusive results. The method used was shown to be suitable for application to quality control, and it revealed the poor quality of the simvastatin capsules produced by some compounding pharmacies.

  5. Results of high heat flux qualification tests of W monoblock components for WEST

    NASA Astrophysics Data System (ADS)

    Greuner, H.; Böswirth, B.; Lipa, M.; Missirlian, M.; Richou, M.

    2017-12-01

    One goal of the WEST project (W Environment in Steady-state Tokamak) is the manufacturing, quality assessment and operation of ITER-like actively water-cooled divertor plasma facing components made of tungsten. Six W monoblock plasma facing units (PFUs) from different suppliers have been successfully evaluated in the high heat flux test facility GLADIS at IPP. Each PFU is equipped with 35 W monoblocks of an ITER-like geometry. However, the W blocks are made of different tungsten grades and the suppliers applied different bonding techniques between tungsten and the inserted Cu-alloy cooling tubes. The intention of the HHF test campaign was to assess the manufacturing quality of the PFUs on the basis of a statistical analysis of the surface temperature evolution of the individual W monoblocks during thermal loading with 100 cycles at 10 MW m-2. These tests confirm the non-destructive examinations performed by the manufacturer and CEA prior to the installation of the WEST platform, and no defects of the components were detected.

  6. [Study on the deteriorating course of fresh milk by laser-induced fluorescence spectra].

    PubMed

    Liu, J; Yu, C Q; Li, J Z; Yan, J X

    2001-12-01

    Along with the development of living standard, people's demand for food quality and food hygiene also rises. People demand food not only with rich nutrition, inexpensive price, but also with safety. So food hygiene test is paid common attention of society. Milk is a nourishing food and is loved by people. Sour milk goods from milk is also in great demand. But nourishing foods are good for growing many microbes. Fresh milk and sour milk are easy contaminated by microbes and go bad. Laser-induced fluorescence (LIF) technology is an important part of modern optics. It is broadly applied in biomedicine, diagnostics, test of food hygiene, environment protecting, owing to its high sensitivity, high speed, automation, untouched testing. In this paper, we attempted to LIF technology to test milk food quality. We used the third harmonics pulsed Nd:YAG laser (355 nm) as the exciting source, and a multi-track spectrometer as the detector and measured the intensities of apply LIF of fresh milk and sour milk during their deteriorating course. Test system and test method are introduced, fluorescence spectra of deteriorating course are also attached. The test result makes clear that there are close connection between deteriorating course and fluorescence spectra.

  7. The Effect of Different Location of Muscle on Quality of Frozen Simmental Ongole Grade Male Meat

    NASA Astrophysics Data System (ADS)

    Triasih, D.; Krisdiani, D.; Riyanto, J.; Pratitis, W.; Widyawati, S. D.

    2018-02-01

    The aim of this research was to identify the influence of different types of muscle on the characteristics physical quality frozen meat of Simmental Ongole Crossbreed Male frozen meat. The research had been conducted at the Laboratory of Meat Technology and Processing and Laboratory of Nutritional Biochemistry, Faculty of Animal Science, University GadjahMada, Yogyakarta. The physical quality with 4 levels treatments, the name was Biceps femoris (BF), Longissimus dorsi (LD), Triceps brachii (TB), and Pectoralis profundus (PP). The chemical quality with 3 levels treatments, the name was Biceps femoris (BF), Longissimus dorsi (LD), and Triceps brachii (TB). The research used Completely Randomized Design with 5 replications for each treatment. The variables of the physical quality test were pH, tenderness, cooking loss, and water-holding capacity. The chemical quality test were water content, protein content, fat content, and cholesterol content. The result of the physical quality test showed that the different types of muscle were significantly influence the pH value (P<0,01), also the influence the tenderness and cooking loss (P<0,05), but there was no significant different on water-holding capacity. The chemical quality test showed that the different types of muscle significant influenced on protein content and fat content (P<0,01). They were significant different (P<0,05) on water content, and there was significant effect (P<0,05) on cholesterol. In conclusion, the BF have high value of pH, cooking loss, water content, protein content, and cholesterol than other muscle, but have low value of tenderness and fat content.

  8. Test/QA plan for the validation of the verification protocol for low speed pesticide spray drift reduction technologies for row and field crops

    EPA Science Inventory

    This test/QA plan for evaluation the generic test protocol for high speed wind tunnel, representing aerial application, pesticide spray drift reduction technologies (DRT) for row and field crops is in conformance with EPA Requirements for Quality Assurance Project Plans (EPA QA/R...

  9. Nondestructive Testing Eddy Current Equipment, Methods and Applications RQA/M1-5330.12 (V-II).

    ERIC Educational Resources Information Center

    National Aeronautics and Space Administration, Huntsville, AL. George C. Marshall Space Flight Center.

    As one in the series of programmed instruction handbooks, prepared by the U. S. space program, home study material is presented in this volume concerning familiarization and orientation on eddy current testing. The subject is presented under the following headings: Test Coils, Methods and Indications, and Applications. High product quality and…

  10. SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harpool, K; De La Fuente Herman, T; Ahmad, S

    Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dosemore » verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.« less

  11. Do highly ornamented and less parasitized males have high quality sperm? – an experimental test for parasite-induced reproductive trade-offs in European minnow (Phoxinus phoxinus)

    PubMed Central

    Kekäläinen, Jukka; Pirhonen, Juhani; Taskinen, Jouni

    2014-01-01

    Parasites take their resources from hosts and thus directly reduce available resources for hosts’ own body functions, such as growth and reproduction. Furthermore, parasite infections cause significant indirect costs to their hosts in terms of increased investments on immune defense. In this study, we investigated the impact of parasite infection on the sperm quality and expression of secondary sexual ornamentation (saturation of the red abdominal colouration and number of breeding tubercles) in the Eurasian minnow (Phoxinus phoxinus). We exposed minnows to a high and low dose of common nonspecific fish ectoparasite, the glochidia larvae of duck mussel (Anodonta anatina) and tested whether parasite infection leads to trade-off in sperm quality and/or ornamental expression. We found that glochidia infection reduces the curvature of the sperm swimming trajectory, number of breeding tubercles, and possibly male competitive ability, but does not affect expression of male color ornamentation. Furthermore, glochidia infection was found to reduce sperm motility, but only when all the noninfected individuals were excluded from the model. Supporting one of the predictions by phenotype-linked fertility hypothesis both in high-infection and low-infection group male breeding colouration was positively associated with sperm quality. Our results suggest that although glochidia infection may have negative impact on male reproductive success, parasite-induced costs may not create strong trade-off between breeding colouration and sperm quality or that such trade-off become detectable only in resource-limited conditions. PMID:25540686

  12. Off the ear with no loss in speech understanding: comparing the RONDO and the OPUS 2 cochlear implant audio processors.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Büchner, Andreas; Müller, Joachim; Hempel, John Martin; Löwenheim, Hubert; Mlynski, Robert

    2017-03-01

    The RONDO is a single-unit cochlear implant audio processor, which omits the need for a behind-the-ear (BTE) audio processor. The primary aim was to compare speech perception results in quiet and in noise with the RONDO and the OPUS 2, a BTE audio processor. Secondary aims were to determine subjects' self-assessed levels of sound quality and gather subjective feedback on RONDO use. All speech perception tests were performed with the RONDO and the OPUS 2 behind-the-ear audio processor at 3 test intervals. Subjects were required to use the RONDO between test intervals. Subjects were tested at upgrade from the OPUS 2 to the RONDO and at 1 and 6 months after upgrade. Speech perception was determined using the Freiburg Monosyllables in quiet test and the Oldenburg Sentence Test (OLSA) in noise. Subjective perception was determined using the Hearing Implant Sound Quality Index (HISQUI 19 ), and a RONDO device-specific questionnaire. 50 subjects participated in the study. Neither speech perception scores nor self-perceived sound quality scores were significantly different at any interval between the RONDO and the OPUS 2. Subjects reported high levels of satisfaction with the RONDO. The RONDO provides comparable speech perception to the OPUS 2 while providing users with high levels of satisfaction and comfort without increasing health risk. The RONDO is a suitable and safe alternative to traditional BTE audio processors.

  13. Validation of the Italian version of the Laval questionnaire: health-related quality of life in subjects with obesity.

    PubMed

    Donini, Lorenzo Maria; Rosano, Aldo; Di Lazzaro, Luca; Poggiogalle, Eleonora; Lubrano, Carla; Migliaccio, Silvia; Carbonelli, Mariagrazia; Pinto, Alessandro; Lenzi, Andrea

    2017-05-15

    Obesity is associated to increased risk of metabolic comorbidity as well as increased mortality. Notably, obesity is also associated to the impairment of the psychological status and of quality of life. Only three questionnaires are available in the Italian language evaluating the health-related quality of life in subjects with obesity. The aim of the present study was to test the validity and reliability of the Italian version of the Laval Questionnaire. The original French version was translated into Italian and back-translated by a French native speaker. 273 subjects with obesity (Body Mass Index ≥ 30 kg/m 2 ) were enrolled; the Italian version of the Laval Questionnaire and the O.R.Well-97 questionnaire were administered in order to assess health- related quality of life. The Laval questionnaire consists of 44 items distributed in 6 domains (symptoms, activity/mobility, personal hygiene/clothing, emotions, social interaction, sexual life). Disability and overall psychopathology levels were assessed through the TSD-OC test (SIO test for obesity correlated disabilities) and the SCL-90 (Symptom Checklist-90) questionnaire, respectively. To verify the validity of the Italian version, the analysis of internal consistency, test-retest reliability, and construct validity were performed. The observed proportion of agreement concordance of results was 50.2% with Cohen's K = 0.336 (CI 95%: 0.267-0.404), indicating a fair agreement between the two tests. Test-retest correlation was statistically significant (ρ = 0.82; p < 0.01); validity (standardized Chronbach's alpha) was considered reliable (α > 0.70). The analysis of construct validity showed a statistically significant association in terms of both total score (ρ = -0.66) and scores at each single domain (p < 0.01). A high correlation (p < 0.01) was observed between Laval questionnaire total and single domain scores and other related measures (Body Mass Index, TSD-OC scores, SCL-90 global severity index), revealing a high construct validity of the test. The Italian version of the Laval Questionnaire is a valid and reliable measure to assess the health-related quality of life in subjects with obesity.

  14. A quantitative method to analyze the quality of EIA information in wind energy development and avian/bat assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Tony, E-mail: tc282@nau.edu; Nielsen, Erik, E-mail: erik.nielsen@nau.edu; Auberle, William, E-mail: william.auberle@nau.edu

    2013-01-15

    The environmental impact assessment (EIA) has been a tool for decision makers since the enactment of the National Environmental Policy Act (NEPA). Since that time, few analyses have been performed to verify the quality of information and content within EIAs. High quality information within assessments is vital in order for decision makers, stake holders, and the public to understand the potential impact of proposed actions on the ecosystem and wildlife species. Low quality information has been a major cause for litigation and economic loss. Since 1999, wind energy development has seen an exponential growth with unknown levels of impact onmore » wildlife species, in particular bird and bat species. The purpose of this article is to: (1) develop, validate, and apply a quantitative index to review avian/bat assessment quality for wind energy EIAs; and (2) assess the trends and status of avian/bat assessment quality in a sample of wind energy EIAs. This research presents the development and testing of the Avian and Bat Assessment Quality Index (ABAQI), a new approach to quantify information quality of ecological assessments within wind energy development EIAs in relation to avian and bat species based on review areas and factors derived from 23 state wind/wildlife siting guidance documents. The ABAQI was tested through a review of 49 publicly available EIA documents and validated by identifying high variation in avian and bat assessments quality for wind energy developments. Of all the reviewed EIAs, 66% failed to provide high levels of preconstruction avian and bat survey information, compared to recommended factors from state guidelines. This suggests the need for greater consistency from recommended guidelines by state, and mandatory compliance by EIA preparers to avoid possible habitat and species loss, wind energy development shut down, and future lawsuits. - Highlights: Black-Right-Pointing-Pointer We developed, validated, and applied a quantitative index to review avian/bat assessment quality for wind energy EIAs. Black-Right-Pointing-Pointer We assessed the trends and status of avian/bat assessment quality in a sample of wind energy EIAs. Black-Right-Pointing-Pointer Applied index to 49 EIA documents and identified high variation in assessment quality for wind energy developments. Black-Right-Pointing-Pointer For the reviewed EIAs, 66% provided inadequate preconstruction avian and bat survey information.« less

  15. Fast and accurate de novo genome assembly from long uncorrected reads

    PubMed Central

    Vaser, Robert; Sović, Ivan; Nagarajan, Niranjan

    2017-01-01

    The assembly of long reads from Pacific Biosciences and Oxford Nanopore Technologies typically requires resource-intensive error-correction and consensus-generation steps to obtain high-quality assemblies. We show that the error-correction step can be omitted and that high-quality consensus sequences can be generated efficiently with a SIMD-accelerated, partial-order alignment–based, stand-alone consensus module called Racon. Based on tests with PacBio and Oxford Nanopore data sets, we show that Racon coupled with miniasm enables consensus genomes with similar or better quality than state-of-the-art methods while being an order of magnitude faster. PMID:28100585

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, L; Shen, C; Wang, J

    Purpose: To reduce cone beam CT (CBCT) imaging dose, we previously proposed a progressive dose control (PDC) scheme to employ temporal correlation between CBCT images at different fractions for image quality enhancement. A temporal non-local means (TNLM) method was developed to enhance quality of a new low-dose CBCT using existing high-quality CBCT. To enhance a voxel value, the TNLM method searches for similar voxels in a window. Due to patient deformation among the two CBCTs, a large searching window was required, reducing image quality and computational efficiency. This abstract proposes a deformation-assisted TNLM (DA-TNLM) method to solve this problem. Methods:more » For a low-dose CBCT to be enhanced using a high-quality CBCT, we first performed deformable image registration between the low-dose CBCT and the high-quality CBCT to approximately establish voxel correspondence between the two. A searching window for a voxel was then set based on the deformation vector field. Specifically, the search window for each voxel was shifted by the deformation vector. A TNLM step was then applied using only voxels within this determined window to correct image intensity at the low-dose CBCT. Results: We have tested the proposed scheme on simulated CIRS phantom data and real patient data. The CITS phantom was scanned on Varian onboard imaging CBCT system with coach shifting and dose reducing for each time. The real patient data was acquired in four fractions with dose reduced from standard CBCT dose to 12.5% of standard dose. It was found that the DA-TNLM method can reduce total dose by over 75% on average in the first four fractions. Conclusion: We have developed a PDC scheme which can enhance the quality of image scanned at low dose using a DA-TNLM method. Tests in phantom and patient studies demonstrated promising results.« less

  17. Survey of the prevalence and methodology of quality assurance for B-mode ultrasound image quality among veterinary sonographers.

    PubMed

    Hoscheit, Larry P; Heng, Hock Gan; Lim, Chee Kin; Weng, Hsin-Yi

    2018-05-01

    Image quality in B-mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B-mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B-mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross-sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34-52%) and 26% (40/156: 95% confidence interval 19-33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0-6%, quality control testing 95% confidence interval: 0-11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B-mode ultrasound equipment/components. © 2018 American College of Veterinary Radiology.

  18. Development and testing of a superconducting link for an IR detector

    NASA Technical Reports Server (NTRS)

    Caton, R.; Selim, R.

    1991-01-01

    The development and testing of a ceramic superconducting link for an infrared detector is summarized. Areas of study included the materials used, the electrical contacts, radiation and temperature cycling effects, aging, thermal conductivity, and computer models of an ideal link. Materials' samples were processed in a tube furnace at temperatures of 840 C to 865 C for periods up to 17 days and transition temperatures and critical current densities were recorded. The project achieved better quality high superconducting transition temperature material through improved processing and also achieved high quality electrical contacts. Studies on effects of electron irradiation, temperature cycling, and aging on superconducting properties indicate that the materials will be suitable for space applications. Various presentations and publications on the study's results are reported.

  19. Hypothesis driven drug design: improving quality and effectiveness of the design-make-test-analyse cycle.

    PubMed

    Plowright, Alleyn T; Johnstone, Craig; Kihlberg, Jan; Pettersson, Jonas; Robb, Graeme; Thompson, Richard A

    2012-01-01

    In drug discovery, the central process of constructing and testing hypotheses, carefully conducting experiments and analysing the associated data for new findings and information is known as the design-make-test-analyse cycle. Each step relies heavily on the inputs and outputs of the other three components. In this article we report our efforts to improve and integrate all parts to enable smooth and rapid flow of high quality ideas. Key improvements include enhancing multi-disciplinary input into 'Design', increasing the use of knowledge and reducing cycle times in 'Make', providing parallel sets of relevant data within ten working days in 'Test' and maximising the learning in 'Analyse'. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Operational Results From a High Power Alternator Test Bed

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2007-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was used to simulate the operating conditions and evaluate the performance of the ATU and its interaction with various LPSF components in accordance with the current Fission Surface Power System (FSPS) requirements. The testing was carried out at the breadboard development level. These results successfully demonstrated excellent ATU power bus characteristics and rectified user load power quality during steady state and transient conditions. Information gained from this work could be used to assist the design and primary power quality considerations for a possible future FSPS. This paper describes the LPSF components and some preliminary test results.

  1. Resource quality or competition: why increase resource acceptance in the presence of conspecifics?

    PubMed Central

    Nufio, César R.; Papaj, Daniel R.

    2011-01-01

    Some animal species increase resource acceptance rates in the presence of conspecifics. Such responses may be adaptive if the presence of conspecifics is a reliable indicator of resource quality. Similarly, these responses could represent an adaptive reduction in choosiness under high levels of scramble competition. Although high resource quality and high levels of scramble competition should both favor increased resource acceptance, the contexts in which the increase occurs should differ. In this paper, we tested the effect of social environment on egg-laying and aggressive behavior in the walnut fly, Rhagoletis juglandis, in multiple contexts to determine whether increased resource acceptance in the presence of conspecifics was better viewed as a response to increased host quality or increased competition. We found that grouped females oviposit more readily than isolated females when provided small (low-quality) artificial hosts but not when provided large (high-quality) artificial hosts, indicating that conspecific presence reduces choosiness. Increased resource acceptance was observed even when exposure to conspecifics was temporally or spatially separate from exposure to the resource. Finally, we found that individuals showed reduced aggression after being housed in groups, as expected under high levels of scramble competition. These results indicate that the pattern of resource acceptance in the presence of conspecifics may be better viewed as a response to increased scramble competition rather than as a response to public information about resource quality. PMID:22479135

  2. Resource quality or competition: why increase resource acceptance in the presence of conspecifics?

    PubMed

    Davis, Jeremy M; Nufio, César R; Papaj, Daniel R

    2011-07-01

    Some animal species increase resource acceptance rates in the presence of conspecifics. Such responses may be adaptive if the presence of conspecifics is a reliable indicator of resource quality. Similarly, these responses could represent an adaptive reduction in choosiness under high levels of scramble competition. Although high resource quality and high levels of scramble competition should both favor increased resource acceptance, the contexts in which the increase occurs should differ. In this paper, we tested the effect of social environment on egg-laying and aggressive behavior in the walnut fly, Rhagoletis juglandis, in multiple contexts to determine whether increased resource acceptance in the presence of conspecifics was better viewed as a response to increased host quality or increased competition. We found that grouped females oviposit more readily than isolated females when provided small (low-quality) artificial hosts but not when provided large (high-quality) artificial hosts, indicating that conspecific presence reduces choosiness. Increased resource acceptance was observed even when exposure to conspecifics was temporally or spatially separate from exposure to the resource. Finally, we found that individuals showed reduced aggression after being housed in groups, as expected under high levels of scramble competition. These results indicate that the pattern of resource acceptance in the presence of conspecifics may be better viewed as a response to increased scramble competition rather than as a response to public information about resource quality.

  3. [The methodological assessment and qualitative evaluation of psychometric performance tests based on the example of modern tests that assess reading and spelling skills].

    PubMed

    Galuschka, Katharina; Rothe, Josefine; Schulte-Körne, Gerd

    2015-09-01

    This article looks at a means of objectively evaluating the quality of psychometric tests. This approach enables users to evaluate psychometric tests based on their methodological characteristics, in order to decide which instrument should be used. Reading and spelling assessment tools serve as examples. The paper also provides a review of German psychometric tests for the assessment of reading and spelling skills. This method facilitates the identification of psychometric tests.of high methodological quality which can be used for the assessment of reading and spelling skills. Reading performance should ideally be assessed with the following instruments: ELFE 1-6, LGVT 6-12, LESEN 6-7, LESEN 8-9, or WLLP-R. The tests to be used for the evaluation of spelling skills are DERET 1-2+, DERET 3-4+, WRT 1+, WRT 2+, WRT 3+, WRT 4+ or HSP 1-10.

  4. Non-pest prey do not disrupt aphid predation by a web-building spider.

    PubMed

    Welch, K D; Whitney, T D; Harwood, J D

    2016-02-01

    A generalist predator's ability to contribute to biological control is influenced by the decisions it makes during foraging. Predators often use flexible foraging tactics, which allows them to pursue specific types of prey at the cost of reducing the likelihood of capturing other types of prey. When a pest insect has low nutritional quality or palatability for a predator, the predator is likely to reject that prey in favour of pursuing alternative, non-pest prey. This is often thought to limit the effectiveness of generalist predators in consuming aphids, which are of low nutritional quality for many generalist predators. Here, we report behavioural assays that test the hypothesis that the generalist predator, Grammonota inornata (Araneae: Linyphiidae), preferentially forages for a non-pest prey with high nutritional quality (springtails), and rejects a pest prey with low nutritional quality (aphids). In no-choice assays, molecular gut-content analysis revealed that spiders continued to feed on the low-quality aphids at high rates, even when high-quality springtails were readily available. When provided a choice between aphids and springtails in two-way choice tests, spiders did not show the expected preference for springtails. Decision-making by spiders during foraging therefore appears to be sub-optimal, possibly because of attraction to the less frequently encountered of two preys as part of a dietary diversification strategy. These results indicate that behavioural preferences alone do not necessarily compromise the pest-suppression capacity of natural enemies: even nutritionally sub-optimal pest prey can potentially be subject to predation and suppression by natural enemies.

  5. Linking service quality, customer satisfaction, and behavioral intention.

    PubMed

    Woodside, A G; Frey, L L; Daly, R T

    1989-12-01

    Based on the service quality and script theory literature, a framework of relationships among service quality, customer satisfaction, and behavioral intention for service purchases is proposed. Specific models are developed from the general framework and the models are applied and tested for the highly complex and divergent consumer service of overnight hospital care. Service quality, customer satisfaction, and behavioral intention data were collected from recent patients of two hospitals. The findings support the specific models and general framework. Implications for theory, service marketing, and future research are discussed.

  6. Modeling of liquid flow in surface discontinuities

    NASA Astrophysics Data System (ADS)

    Lobanova, I. S.; Meshcheryakov, V. A.; Kalinichenko, A. N.

    2018-01-01

    Polymer composite and metallic materials have found wide application in various industries such as aviation, rocket, car manufacturing, ship manufacturing, etc. Many design elements need permanent quality control. Ensuring high quality and reliability of products is impossible without effective nondestructive testing methods. One of these methods is penetrant testing using penetrating substances based on liquid penetration into defect cavities. In this paper, we propose a model of liquid flow to determine the rates of filling the defect cavities with various materials and, based on this, to choose optimal control modes.

  7. Flying qualities criteria for GA single pilot IFR operations

    NASA Technical Reports Server (NTRS)

    Bar-Gill, A.

    1982-01-01

    The flying qualities criteria in general aviation (GA) to decrease accidents are discussed. The following in-flight research is discussed: (1) identification of key aerodynamic configurations; (2) implementation of an in-flight simulator; (3) mission matrix design; (4) experimental systems; (5) data reduction; (6) optimal flight path reconstruction. Some of the accomplished work is reported: an integrated flight testing and flight path reconstruction methodology was developd, high accuracy in trajectory estimation was achieved with an experimental setup, and a part of the flight test series was flown.

  8. Molybdenum-rhenium alloy based high-Q superconducting microwave resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Vibhor, E-mail: v.singh@tudelft.nl; Schneider, Ben H.; Bosman, Sal J.

    2014-12-01

    Superconducting microwave resonators (SMRs) with high quality factors have become an important technology in a wide range of applications. Molybdenum-Rhenium (MoRe) is a disordered superconducting alloy with a noble surface chemistry and a relatively high transition temperature. These properties make it attractive for SMR applications, but characterization of MoRe SMR has not yet been reported. Here, we present the fabrication and characterization of SMR fabricated with a MoRe 60–40 alloy. At low drive powers, we observe internal quality-factors as high as 700 000. Temperature and power dependence of the internal quality-factors suggest the presence of the two level systems from themore » dielectric substrate dominating the internal loss at low temperatures. We further test the compatibility of these resonators with high temperature processes, such as for carbon nanotube chemical vapor deposition growth, and their performance in the magnetic field, an important characterization for hybrid systems.« less

  9. Evaluation of interaction properties of geosynthetics in cohesive soils : LTRC reinforced-soil test wall.

    DOT National Transportation Integrated Search

    2004-01-01

    This report presents the construction and performance evaluation of the LTRC reinforced-soil test wall. The 20 ft. high, 160 ft. long wall was constructed using low quality backfill. Its vertical front facing was constructed with modular blocks. It c...

  10. The Negative Consequences of Teacher Competency Testing.

    ERIC Educational Resources Information Center

    Gallegos, Arnold M.

    1984-01-01

    Negative consequences of minimum competency testing for teacher candidates include the waste of human potential resulting from the disproportionately high failure rate of minority teacher candidates and the danger of lessening the pressure for needed curriculum reforms. This essay urges seeking alternative methods for improving the quality of…

  11. A machine learning model to determine the accuracy of variant calls in capture-based next generation sequencing.

    PubMed

    van den Akker, Jeroen; Mishne, Gilad; Zimmer, Anjali D; Zhou, Alicia Y

    2018-04-17

    Next generation sequencing (NGS) has become a common technology for clinical genetic tests. The quality of NGS calls varies widely and is influenced by features like reference sequence characteristics, read depth, and mapping accuracy. With recent advances in NGS technology and software tools, the majority of variants called using NGS alone are in fact accurate and reliable. However, a small subset of difficult-to-call variants that still do require orthogonal confirmation exist. For this reason, many clinical laboratories confirm NGS results using orthogonal technologies such as Sanger sequencing. Here, we report the development of a deterministic machine-learning-based model to differentiate between these two types of variant calls: those that do not require confirmation using an orthogonal technology (high confidence), and those that require additional quality testing (low confidence). This approach allows reliable NGS-based calling in a clinical setting by identifying the few important variant calls that require orthogonal confirmation. We developed and tested the model using a set of 7179 variants identified by a targeted NGS panel and re-tested by Sanger sequencing. The model incorporated several signals of sequence characteristics and call quality to determine if a variant was identified at high or low confidence. The model was tuned to eliminate false positives, defined as variants that were called by NGS but not confirmed by Sanger sequencing. The model achieved very high accuracy: 99.4% (95% confidence interval: +/- 0.03%). It categorized 92.2% (6622/7179) of the variants as high confidence, and 100% of these were confirmed to be present by Sanger sequencing. Among the variants that were categorized as low confidence, defined as NGS calls of low quality that are likely to be artifacts, 92.1% (513/557) were found to be not present by Sanger sequencing. This work shows that NGS data contains sufficient characteristics for a machine-learning-based model to differentiate low from high confidence variants. Additionally, it reveals the importance of incorporating site-specific features as well as variant call features in such a model.

  12. Parameter-based estimation of CT dose index and image quality using an in-house android™-based software

    NASA Astrophysics Data System (ADS)

    Mubarok, S.; Lubis, L. E.; Pawiro, S. A.

    2016-03-01

    Compromise between radiation dose and image quality is essential in the use of CT imaging. CT dose index (CTDI) is currently the primary dosimetric formalisms in CT scan, while the low and high contrast resolutions are aspects indicating the image quality. This study was aimed to estimate CTDIvol and image quality measures through a range of exposure parameters variation. CTDI measurements were performed using PMMA (polymethyl methacrylate) phantom of 16 cm diameter, while the image quality test was conducted by using catphan ® 600. CTDI measurements were carried out according to IAEA TRS 457 protocol using axial scan mode, under varied parameters of tube voltage, collimation or slice thickness, and tube current. Image quality test was conducted accordingly under the same exposure parameters with CTDI measurements. An Android™ based software was also result of this study. The software was designed to estimate the value of CTDIvol with maximum difference compared to actual CTDIvol measurement of 8.97%. Image quality can also be estimated through CNR parameter with maximum difference to actual CNR measurement of 21.65%.

  13. Can editors save peer review from peer reviewers?

    PubMed

    D'Andrea, Rafael; O'Dwyer, James P

    2017-01-01

    Peer review is the gold standard for scientific communication, but its ability to guarantee the quality of published research remains difficult to verify. Recent modeling studies suggest that peer review is sensitive to reviewer misbehavior, and it has been claimed that referees who sabotage work they perceive as competition may severely undermine the quality of publications. Here we examine which aspects of suboptimal reviewing practices most strongly impact quality, and test different mitigating strategies that editors may employ to counter them. We find that the biggest hazard to the quality of published literature is not selfish rejection of high-quality manuscripts but indifferent acceptance of low-quality ones. Bypassing or blacklisting bad reviewers and consulting additional reviewers to settle disagreements can reduce but not eliminate the impact. The other editorial strategies we tested do not significantly improve quality, but pairing manuscripts to reviewers unlikely to selfishly reject them and allowing revision of rejected manuscripts minimize rejection of above-average manuscripts. In its current form, peer review offers few incentives for impartial reviewing efforts. Editors can help, but structural changes are more likely to have a stronger impact.

  14. External quality assessment program for detection of glucose-6-phosphate dehydrogenase deficiency in the Guangxi region.

    PubMed

    Tang, Juan; Zhou, Xiangyang; Liu, Xiaochun; Ning, Leping; Zhou, Weiya; He, Yi

    2017-09-01

    The aim of this study is to improve the quality of testing for glucose-6-phosphate dehydrogenase (G6PD) deficiency through evaluation and analysis of the laboratory tests for G6PD activity. External quality assessment (EQA) was carried out twice per year with five samples each from 2014 to 2016. Samples were used for quantitative and qualitative assays. Quantitative results were collected, qualitative results were determined with reference values, and information about methods, reagents and instruments from participating laboratories within the required time. Laboratory performance scores, coefficient of variation (CV), and the rates of false negative and positive results were calculated. As a result, a total of 2,834 cases of negative quality control (QC) samples and 2,451 cases of positive QC samples were assessed, where the rates of false negative and false positive results were 1.31% (37/2,834) and 1.34% (33/2,451), respectively. Quantitative results indicated an increasing trend in testing quality, which were consistent with conclusions based on the comparison of EQA full-score and acceptable ratio in six assessments. The 2nd assay in 2016 had the best full-score ratio of 68.9% (135/196) and best acceptable ratio of 84.2% (165/196). There was a decreasing trend in the average CV of six reagents produced in China, and the range of average CV increased to 14.6-23.6% in 2016. The average CV of low level and high level samples was 22.5% and 15.3%, respectively, demonstrating that samples with low G6PD activity have greater interlaboratory CV values. In conclusion, laboratories improved their testing quality and provided better diagnostic service for G6PD deficiency in areas with high incidence after participation in the EQA program in the Guangxi region.

  15. Biochemical tests of placental function for assessment in pregnancy.

    PubMed

    Neilson, James P

    2012-08-15

    Biochemical tests of placental or feto-placental function were widely used in the 1960s and 1970s in high-risk pregnancies to try to predict, and thus try to avoid, adverse fetal outcome. To assess the effects of performing biochemical tests of placental function in high-risk, low-risk, or unselected pregnancies. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (10 May 2012). Controlled trials (randomized or 'quasi-randomized') that compare the use of biochemical tests of placental function in pregnancy with non-use. Trial quality was assessed and data were extracted by the review author. A single eligible trial of poor quality was identified. It involved 622 women with high-risk pregnancies who had had plasma (o)estriol estimations. Women were allocated to have their (o)estriol results revealed or concealed on the basis of hospital record number (with attendant risk of selection bias). There were no obvious differences in perinatal mortality (relative risk (RR) 0.88, 95% confidence interval (CI) 0.36 to 2.13) or planned delivery (RR 0.97, 95% CI 0.81 to 1.15) between the two groups. The available trial data do not support the use of (o)estriol estimation in high-risk pregnancies. The single small trial available does not have the power to exclude a beneficial effect but this is probably of historical interest since biochemical testing has been superseded by biophysical testing in antepartum fetal assessment.

  16. Bridging the Gap Between Validation and Implementation of Non-Animal Veterinary Vaccine Potency Testing Methods

    PubMed Central

    Dozier, Samantha; Brown, Jeffrey; Currie, Alistair

    2011-01-01

    Simple Summary Many vaccines are tested for quality in experiments that require the use of large numbers of animals in procedures that often cause significant pain and distress. Newer technologies have fostered the development of vaccine quality control tests that reduce or eliminate the use of animals, but the availability of these newer methods has not guaranteed their acceptance by regulators or use by manufacturers. We discuss a strategic approach that has been used to assess and ultimately increase the use of non-animal vaccine quality tests in the U.S. and U.K. Abstract In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches. PMID:26486625

  17. A preclinical physiological assay to test modulation of knee joint pain in the spinal cord: effects of oxycodone and naproxen.

    PubMed

    Miranda, Jason A; Stanley, Phil; Gore, Katrina; Turner, Jamie; Dias, Rebecca; Rees, Huw

    2014-01-01

    Sensory processing in the spinal cord during disease states can reveal mechanisms for novel treatments, yet very little is known about pain processing at this level in the most commonly used animal models of articular pain. Here we report a test of the prediction that two clinically effective compounds, naproxen (an NSAID) and oxycodone (an opiate), are efficacious in reducing the response of spinal dorsal horn neurons to noxious knee joint rotation in the monosodium iodoacetate (MIA) sensitized rat. The overall objective for these experiments was to develop a high quality in vivo electrophysiology assay to confidently test novel compounds for efficacy against pain. Given the recent calls for improved preclinical experimental quality we also developed and implemented an Assay Capability Tool to determine the quality of our assay and ensure the quality of our results. Spinal dorsal horn neurons receiving input from the hind limb knee joint were recorded in anesthetized rats 14 days after they were sensitized with 1 mg of MIA. Intravenous administered oxycodone and naproxen were each tested separately for their effects on phasic, tonic, ongoing and afterdischarge action potential counts in response to innocuous and noxious knee joint rotation. Oxycodone reduced tonic spike counts more than the other measures, doing so by up to 85%. Tonic counts were therefore designated the primary endpoint when testing naproxen which reduced counts by up to 81%. Both reductions occurred at doses consistent with clinically effective doses for osteoarthritis. These results demonstrate that clinically effective doses of standard treatments for osteoarthritis reduce pain processing measured at the level of the spinal cord for two different mechanisms. The Assay Capability Tool helped to guide experimental design leading to a high quality and robust preclinical assay to use in discovering novel treatments for pain.

  18. A Preclinical Physiological Assay to Test Modulation of Knee Joint Pain in the Spinal Cord: Effects of Oxycodone and Naproxen

    PubMed Central

    Miranda, Jason A.; Stanley, Phil; Gore, Katrina; Turner, Jamie; Dias, Rebecca; Rees, Huw

    2014-01-01

    Sensory processing in the spinal cord during disease states can reveal mechanisms for novel treatments, yet very little is known about pain processing at this level in the most commonly used animal models of articular pain. Here we report a test of the prediction that two clinically effective compounds, naproxen (an NSAID) and oxycodone (an opiate), are efficacious in reducing the response of spinal dorsal horn neurons to noxious knee joint rotation in the monosodium iodoacetate (MIA) sensitized rat. The overall objective for these experiments was to develop a high quality in vivo electrophysiology assay to confidently test novel compounds for efficacy against pain. Given the recent calls for improved preclinical experimental quality we also developed and implemented an Assay Capability Tool to determine the quality of our assay and ensure the quality of our results. Spinal dorsal horn neurons receiving input from the hind limb knee joint were recorded in anesthetized rats 14 days after they were sensitized with 1 mg of MIA. Intravenous administered oxycodone and naproxen were each tested separately for their effects on phasic, tonic, ongoing and afterdischarge action potential counts in response to innocuous and noxious knee joint rotation. Oxycodone reduced tonic spike counts more than the other measures, doing so by up to 85%. Tonic counts were therefore designated the primary endpoint when testing naproxen which reduced counts by up to 81%. Both reductions occurred at doses consistent with clinically effective doses for osteoarthritis. These results demonstrate that clinically effective doses of standard treatments for osteoarthritis reduce pain processing measured at the level of the spinal cord for two different mechanisms. The Assay Capability Tool helped to guide experimental design leading to a high quality and robust preclinical assay to use in discovering novel treatments for pain. PMID:25157947

  19. Image quality testing of assembled IR camera modules

    NASA Astrophysics Data System (ADS)

    Winters, Daniel; Erichsen, Patrik

    2013-10-01

    Infrared (IR) camera modules for the LWIR (8-12_m) that combine IR imaging optics with microbolometer focal plane array (FPA) sensors with readout electronics are becoming more and more a mass market product. At the same time, steady improvements in sensor resolution in the higher priced markets raise the requirement for imaging performance of objectives and the proper alignment between objective and FPA. This puts pressure on camera manufacturers and system integrators to assess the image quality of finished camera modules in a cost-efficient and automated way for quality control or during end-of-line testing. In this paper we present recent development work done in the field of image quality testing of IR camera modules. This technology provides a wealth of additional information in contrast to the more traditional test methods like minimum resolvable temperature difference (MRTD) which give only a subjective overall test result. Parameters that can be measured are image quality via the modulation transfer function (MTF) for broadband or with various bandpass filters on- and off-axis and optical parameters like e.g. effective focal length (EFL) and distortion. If the camera module allows for refocusing the optics, additional parameters like best focus plane, image plane tilt, auto-focus quality, chief ray angle etc. can be characterized. Additionally, the homogeneity and response of the sensor with the optics can be characterized in order to calculate the appropriate tables for non-uniformity correction (NUC). The technology can also be used to control active alignment methods during mechanical assembly of optics to high resolution sensors. Other important points that are discussed are the flexibility of the technology to test IR modules with different form factors, electrical interfaces and last but not least the suitability for fully automated measurements in mass production.

  20. The Effect of Handwriting Training on Language Learning among Deaf Children and Their Matched Hearing Peers in China

    ERIC Educational Resources Information Center

    Guan, Connie Qun; Wang, Ye

    2017-01-01

    Comparing deaf and hard of hearing (DHH) children with their hearing peers in learning Chinese, the study tested the lexical quality hypothesis (Perfetti, 1992, 2007), which asserts the importance of building orthographic, phonological, and semantic connections in high-quality lexical representations. DHH children and hearing peers matched on…

  1. Argumentation in Educational Policy Disputes: Competing Visions of Quality and Equity

    ERIC Educational Resources Information Center

    Anagnostopoulos, Dorothea; Lingard, Bob; Sellar, Sam

    2016-01-01

    Current debates about test-based accountability policies revolve around questions of how to ensure that all students have access to high-quality schools and teachers. Whether and how one can meet this goal depend, in part, on the nature of the arguments that policy proponents and opponents mobilize in these debates. This article examines these…

  2. "Vergara" and the Complexities of Teacher Employment Policies. ECS Education Policy Analysis

    ERIC Educational Resources Information Center

    Rowland, Julie

    2015-01-01

    Teaching quality is a crucial factor in student success, contributing to students' short- and long-term learning opportunities. High-quality teaching not only contributes to the improvement of student test scores and graduation rates but also gives students a "strong foundation from which to advance and achieve" in the future. Long term,…

  3. Reel wheels : an application of material science

    Treesearch

    Robert L. Geimer

    1979-01-01

    Circular plates of reconstituted wood were fabricated and destructively tested to appraise the potential of such material for cable reel flanges. The reconstituted wood consisted of flakeboard from quality-cut flakes and also from factory residue. The high quality flakeboard used 0.020- by 1/2-by 2-inch southern pine flakes cut on a disk flaker, whereas the flakeboard...

  4. Water quality status and trends in agriculture-dominated headwaters; a national monitoring network for assessing the effectiveness of national and European manure legislation in The Netherlands.

    PubMed

    Rozemeijer, J C; Klein, J; Broers, H P; van Tol-Leenders, T P; van der Grift, B

    2014-12-01

    Large nutrient losses to groundwater and surface waters are a major drawback of the highly productive agricultural sector in The Netherlands. The resulting high nutrient concentrations in water resources threaten their ecological, industrial, and recreational functions. To mitigate eutrophication problems, legislation on nutrient application in agriculture was enforced in 1986 in The Netherlands. The objective of this study was to evaluate this manure policy by assessing the water quality status and trends in agriculture-dominated headwaters. We used datasets from 5 agricultural test catchments and from 167 existing monitoring locations in agricultural headwaters. Trend analysis for these locations showed a fast reduction of nutrient concentrations after the enforcement of the manure legislation (median slopes of -0.55 mg/l per decade for total nitrogen (N-tot) and -0.020 mg/l per decade for total phosphorus (P-tot)). Still, up to 76 % of the selected locations currently do not comply with either the environmental quality standards (EQSs) for nitrogen (N-tot) or phosphorus (P-tot). This indicates that further improvement of agricultural water quality is needed. We observed that weather-related variations in nutrient concentrations strongly influence the compliance testing results, both for individual locations and for the aggregated results at the national scale. Another important finding is that testing compliance for nutrients based on summer average concentrations may underestimate the agricultural impact on ecosystem health. The focus on summer concentrations does not account for the environmental impact of high winter loads from agricultural headwaters towards downstream water bodies.

  5. Water quality status and trends in agriculture dominated headwaters; a national monitoring network for assessing the effectiveness of national and European manure legislation in The Netherlands

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J.; Klein, J.

    2016-12-01

    Large nutrient losses to groundwater and surface waters are a major drawback of the highly productive agricultural sector in The Netherlands. The resulting high nutrient concentrations in water resources threaten their ecological, industrial, and recreational functions. To mitigate eutrophication problems, legislation on nutrient application in agriculture was enforced in 1986 in The Netherlands. The objective of this study was to evaluate this manure policy by assessing the water quality status and trends in agriculture dominated headwaters. We used datasets from 5 agricultural test catchments and from 167 existing monitoring locations in agricultural headwaters. Trend analysis for these locations showed a fast reduction of nutrient concentrations after the enforcement of the manure legislation (median slopes of -0.55 mg/L per decade for total nitrogen (N-tot) and -0.020 mg/L per decade for total phosphorus (P-tot)). Still, up to 76% of the selected locations currently do not comply with either the environmental quality standards (EQSs) for nitrogen (N-tot) or phosphorus (P-tot). This indicates that further improvement of agricultural water quality is needed. We observed that weather-related variations in nutrient concentrations strongly influence the compliance testing results, both for individual locations and for the aggregated results at the national scale. Another important finding is that testing compliance for nutrients based on summer average concentrations may underestimate the agricultural impact on ecosystem health. The focus on summer concentrations does not account for the environmental impact of high winter loads from agricultural headwaters towards downstream water bodies.

  6. Sleep quality and its relationship with quality of life among high-risk pregnant women (gestational diabetes and hypertension).

    PubMed

    Saadati, Fatemeh; Sehhatiei Shafaei, Fahimeh; Mirghafourvand, Mozhgan

    2018-01-01

    Sleep is one of the most basic human requirements. This research aims at determining the status of sleep quality and its relationship with quality of life among high-risk pregnant women in Tabriz, Iran, in 2015. This research was a sectional study done on 364 qualified women in 28-36 weeks of pregnancy suffering from mild preeclampsia and gestational diabetes. The sampling was done as convenience. Personal-social-midwifery questionnaire, Pittsburg sleep quality, and quality of life in pregnancy (QOL-ORAV) were used for gathering data. Multivariate linear regression model was used for determining the relationship between sleep quality and its subsets with quality of life and controlling confounders. In the current study, the prevalence of sleep disturbance was 96.4%. Mean (SD) of the total score of sleep quality was 10.1 (4.1) and the total score of quality of life was 61.7 (17.3). According to Pearson's correlation test, there was statistically significant relationship between quality of life and sleep quality and all its subsets except sleep duration and use of sleep medication (p < 0.001). Meanwhile, according to the multivariate linear regression model, sleep latency, day time dysfunction, health status, and home air-conditioning were related with quality of life. The findings of current research show that sleep quality is low among high-risk pregnant women and quality of life is medium. So, it is necessary that required training is given by health cares for improving sleep quality and quality of life to mothers.

  7. Autocalibrating motion-corrected wave-encoding for highly accelerated free-breathing abdominal MRI.

    PubMed

    Chen, Feiyu; Zhang, Tao; Cheng, Joseph Y; Shi, Xinwei; Pauly, John M; Vasanawala, Shreyas S

    2017-11-01

    To develop a motion-robust wave-encoding technique for highly accelerated free-breathing abdominal MRI. A comprehensive 3D wave-encoding-based method was developed to enable fast free-breathing abdominal imaging: (a) auto-calibration for wave-encoding was designed to avoid extra scan for coil sensitivity measurement; (b) intrinsic butterfly navigators were used to track respiratory motion; (c) variable-density sampling was included to enable compressed sensing; (d) golden-angle radial-Cartesian hybrid view-ordering was incorporated to improve motion robustness; and (e) localized rigid motion correction was combined with parallel imaging compressed sensing reconstruction to reconstruct the highly accelerated wave-encoded datasets. The proposed method was tested on six subjects and image quality was compared with standard accelerated Cartesian acquisition both with and without respiratory triggering. Inverse gradient entropy and normalized gradient squared metrics were calculated, testing whether image quality was improved using paired t-tests. For respiratory-triggered scans, wave-encoding significantly reduced residual aliasing and blurring compared with standard Cartesian acquisition (metrics suggesting P < 0.05). For non-respiratory-triggered scans, the proposed method yielded significantly better motion correction compared with standard motion-corrected Cartesian acquisition (metrics suggesting P < 0.01). The proposed methods can reduce motion artifacts and improve overall image quality of highly accelerated free-breathing abdominal MRI. Magn Reson Med 78:1757-1766, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Lighting Systems For High Speed Photography Applying Special Metal Halide Discharge Lamps

    NASA Astrophysics Data System (ADS)

    Gillum, Keith M.; Steuernagel, K. H.

    1983-03-01

    High speed photography requires, in addition to a good color quality of the light source, a very high level of illumination. Conventional lighting systems utilizing incandescent lamps or other metal halide lamp types has inherent problems of inefficient light output or poor color quality. Heat generated by incandescent lamps and the power these sources require drive up operating and installation costs. A most economical and practical solution was devised by using the metal halide discharge lamp developed by OSRAM, GmbH of Munich, West Germany. This lamp trade marked the HMITM Metallogen was primarily developed for the needs of the television and motion picture film industry. Due to their high efficiency and other consistent operating qualities these lamps also fulfill the needs of high speed photography, e.g. in crash test facilities, when special engineering activities are carried out. The OSRAM HMITM lamp is an AC discharge metal halide lamp with rare earth additives to increase both the efficiency and light output qualities. Since the lamp is an AC source, a special method had to be developed to overcome the strobing effect, which is normal for AC lamps given their modulated light output, when used with high speed cameras, (e.g. with >1000 fps). This method is based on an increased frequency for the lamp supply voltage coupled with a mix of the light output achieved using a multiphase mains power supply. First developed in 1977, this system using the OSRAM HMITM lamps was installed in a crash test facility of a major automotive manufacturer in West Germany. The design resulted in the best lighting and performance ever experienced. Since that time several other motor companies have made use of this breakthrough. Industrial and scientific users are now considering additional applications use of this advanced high speed lighting system.

  9. EMQN/CMGS best practice guidelines for the molecular genetic testing of Huntington disease.

    PubMed

    Losekoot, Monique; van Belzen, Martine J; Seneca, Sara; Bauer, Peter; Stenhouse, Susan A R; Barton, David E

    2013-05-01

    Huntington disease (HD) is caused by the expansion of an unstable polymorphic trinucleotide (CAG)n repeat in exon 1 of the HTT gene, which translates into an extended polyglutamine tract in the protein. Laboratory diagnosis of HD involves estimation of the number of CAG repeats. Molecular genetic testing for HD is offered in a wide range of laboratories both within and outside the European community. In order to measure the quality and raise the standard of molecular genetic testing in these laboratories, the European Molecular Genetics Quality Network has organized a yearly external quality assessment (EQA) scheme for molecular genetic testing of HD for over 10 years. EQA compares a laboratory's output with a fixed standard both for genotyping and reporting of the results to the referring physicians. In general, the standard of genotyping is very high but the clarity of interpretation and reporting of the test result varies more widely. This emphasizes the need for best practice guidelines for this disorder. We have therefore developed these best practice guidelines for genetic testing for HD to assist in testing and reporting of results. The analytical methods and the potential pitfalls of molecular genetic testing are highlighted and the implications of the different test outcomes for the consultand and his or her family members are discussed.

  10. Clinical Decision Support System to Enhance Quality Control of Spirometry Using Information and Communication Technologies

    PubMed Central

    2014-01-01

    Background We recently demonstrated that quality of spirometry in primary care could markedly improve with remote offline support from specialized professionals. It is hypothesized that implementation of automatic online assessment of quality of spirometry using information and communication technologies may significantly enhance the potential for extensive deployment of a high quality spirometry program in integrated care settings. Objective The objective of the study was to elaborate and validate a Clinical Decision Support System (CDSS) for automatic online quality assessment of spirometry. Methods The CDSS was done through a three step process including: (1) identification of optimal sampling frequency; (2) iterations to build-up an initial version using the 24 standard spirometry curves recommended by the American Thoracic Society; and (3) iterations to refine the CDSS using 270 curves from 90 patients. In each of these steps the results were checked against one expert. Finally, 778 spirometry curves from 291 patients were analyzed for validation purposes. Results The CDSS generated appropriate online classification and certification in 685/778 (88.1%) of spirometry testing, with 96% sensitivity and 95% specificity. Conclusions Consequently, only 93/778 (11.9%) of spirometry testing required offline remote classification by an expert, indicating a potential positive role of the CDSS in the deployment of a high quality spirometry program in an integrated care setting. PMID:25600957

  11. Three Rounds of External Quality Assessment in France to Evaluate the Performance of 28 Platforms for Multiparametric Molecular Testing in Metastatic Colorectal and Non-Small Cell Lung Cancer.

    PubMed

    Dequeker, Elisabeth M C; Keppens, Cleo; Egele, Caroline; Delen, Sofie; Lamy, Aude; Lemoine, Antoinette; Sabourin, Jean-Christophe; Andrieu, Catherine; Ligtenberg, Marjolijn; Fetique, Dominique; Tops, Bastiaan; Descarpentries, Clotilde; Blons, Hélène; Denoux, Yves; Aube, Cécile; Penault-Llorca, Frederique; Hofman, Paul; Leroy, Karen; Le Marechal, Cédric; Doucet, Laurent; Duranton-Tanneur, Valérie; Pedeutour, Florence; Soubeyran, Isabelle; Côté, Jean-François; Emile, Jean-François; Vignaud, Jean-Michel; Monhoven, Nathalie; Haddad, Véronique; Laurent-Puig, Pierre; van Krieken, Han; Nowak, Frederique; Lonchamp, Etienne; Bellocq, Jean-Pierre; Rouleau, Etienne

    2016-03-01

    Personalized medicine has gained increasing importance in clinical oncology, and several clinically important biomarkers are implemented in routine practice. In an effort to guarantee high quality of molecular testing in France, three subsequent external quality assessment rounds were organized at the initiative of the National Cancer Institute between 2012 and 2014. The schemes included clinically relevant biomarkers for metastatic colorectal (KRAS, NRAS, BRAF, PIK3CA, microsatellite instability) and non-small cell lung cancer (EGFR, KRAS, BRAF, PIK3CA, ERBB2), and they represent the first multigene/multicancer studies throughout Europe. In total, 56 laboratories coordinated by 28 regional molecular centers participated in the schemes. Laboratories received formalin-fixed, paraffin-embedded samples and were asked to use routine methods for molecular testing to predict patient response to targeted therapies. They were encouraged to return results within 14 calendar days after sample receipt. Both genotyping and reporting were evaluated separately. During the three external quality assessment rounds, mean genotype scores were all above the preset standard of 90% for all biomarkers. Participants were mainly challenged in case of rare insertions or deletions. Assessment of the written reports showed substantial progress between the external quality assessment schemes on multiple criteria. Several essential elements such as the clinical interpretation of test results and the reason for testing still require improvement by continued external quality assessment education. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  12. PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander; Sahu, Kusum

    2003-01-01

    Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

  13. L-citrulline levels in watermelon cultigens tested in two environments

    USDA-ARS?s Scientific Manuscript database

    Melon producers face increasing production costs and international market competition. Maximizing marketability of high quality watermelon [Citrullus lanatus (Thunb.) Matsum. and Nakai], that also contain high levels of the amino acid phytonutrient L-citrulline, can provide new market niches for th...

  14. Can Sanitary Surveys Replace Water Quality Testing? Evidence from Kisii, Kenya

    PubMed Central

    Misati, Aaron Gichaba; Ogendi, George; Peletz, Rachel; Khush, Ranjiv; Kumpel, Emily

    2017-01-01

    Information about the quality of rural drinking water sources can be used to manage their safety and mitigate risks to health. Sanitary surveys, which are observational checklists to assess hazards present at water sources, are simpler to conduct than microbial tests. We assessed whether sanitary survey results were associated with measured indicator bacteria levels in rural drinking water sources in Kisii Central, Kenya. Overall, thermotolerant coliform (TTC) levels were high: all of the samples from the 20 tested dug wells, almost all (95%) of the samples from the 25 tested springs, and 61% of the samples from the 16 tested rainwater harvesting systems were contaminated with TTC. There were no significant associations between TTC levels and overall sanitary survey scores or their individual components. Contamination by TTC was associated with source type (dug wells and springs were more contaminated than rainwater systems). While sanitary surveys cannot be substituted for microbial water quality results in this context, they could be used to identify potential hazards and contribute to a comprehensive risk management approach. PMID:28178226

  15. The effect of sea-water and fresh-water soaking on the hedonic test of Eucheuma sp. syrup and pudding

    NASA Astrophysics Data System (ADS)

    Novianty, H.; Herandarudewi, S. M. C.

    2018-04-01

    Seaweed is a non-fishery marine commodity that has great opportunities to be developed in Indonesia. One of the seaweed with a high economic value is Eucheuma alvarezii. This seaweed can be used as an additional material in cosmetic and pharmaceutical products or directly used for syrup and pudding. Post-harvest technique conducted by the seaweed farmers will affects the quality of dried and processed products. The purpose of this study is to see the effect of post harvest technique on the quality of dried seaweed and hedonic test (favorable test) of processed product (syrup and pudding). This study was conducted using descriptive method. The study compared dried, syrup, and puddings from two differents post-harvest technique, between salt and fresh-water draining products. The results showed that fresh-water draining technique obtained better quality results organoleptic test. Supported by hedonic test, that showed more panelists were prefered the fresh-water drained products of syrup and pudding. The preference were much higher for the fresh-water drained products in all three catagories of color, taste, and smell.

  16. JPEG vs. JPEG 2000: an objective comparison of image encoding quality

    NASA Astrophysics Data System (ADS)

    Ebrahimi, Farzad; Chamik, Matthieu; Winkler, Stefan

    2004-11-01

    This paper describes an objective comparison of the image quality of different encoders. Our approach is based on estimating the visual impact of compression artifacts on perceived quality. We present a tool that measures these artifacts in an image and uses them to compute a prediction of the Mean Opinion Score (MOS) obtained in subjective experiments. We show that the MOS predictions by our proposed tool are a better indicator of perceived image quality than PSNR, especially for highly compressed images. For the encoder comparison, we compress a set of 29 test images with two JPEG encoders (Adobe Photoshop and IrfanView) and three JPEG2000 encoders (JasPer, Kakadu, and IrfanView) at various compression ratios. We compute blockiness, blur, and MOS predictions as well as PSNR of the compressed images. Our results show that the IrfanView JPEG encoder produces consistently better images than the Adobe Photoshop JPEG encoder at the same data rate. The differences between the JPEG2000 encoders in our test are less pronounced; JasPer comes out as the best codec, closely followed by IrfanView and Kakadu. Comparing the JPEG- and JPEG2000-encoding quality of IrfanView, we find that JPEG has a slight edge at low compression ratios, while JPEG2000 is the clear winner at medium and high compression ratios.

  17. [Fundamentals of quality control systems in medical-biochemical laboratories--the role of marketing].

    PubMed

    Topić, E; Turek, S

    2000-01-01

    The basic criterion for the overall quality system in medical biochemistry laboratories concerning equipment, premises and laboratory staff in primary health care (PHC) (Regulations on quality systems and good laboratory practice of the Croatian Medical Biochemists Chamber, 1995, Regulations on categorization of medical biochemistry laboratories of the Croatian Medical Biochemists Chamber, 1996, EC4: Essential criteria for quality systems in medical laboratories. Eur J Clin Chem Clin Biochem 1997 in medical biochemical laboratories included in the First Croatia health project, Primary health care subproject, has been met by the marketing approach to the project. The equipment ensuring implementation of the complete laboratory program (NN/96), more accurate and precise analytical procedures, and higher reliability of laboratory test results compared with previous equipment, has been purchased by an international tender. Uniform technology and methods of analysis have ensured high standards of good laboratory services, yielding test results than can be transferred from primary to secondary health care level. The new equipment has improved organization between central and detached medical biochemistry laboratory units, while the high quality requirement has led to improvement in the staff structure, e.g., medical biochemists have been employed in laboratories that had previously worked without such a professional. Equipment renewal has been accompanied by proper education for all levels of PHC professionals.

  18. Sample size determination for bibliographic retrieval studies

    PubMed Central

    Yao, Xiaomei; Wilczynski, Nancy L; Walter, Stephen D; Haynes, R Brian

    2008-01-01

    Background Research for developing search strategies to retrieve high-quality clinical journal articles from MEDLINE is expensive and time-consuming. The objective of this study was to determine the minimal number of high-quality articles in a journal subset that would need to be hand-searched to update or create new MEDLINE search strategies for treatment, diagnosis, and prognosis studies. Methods The desired width of the 95% confidence intervals (W) for the lowest sensitivity among existing search strategies was used to calculate the number of high-quality articles needed to reliably update search strategies. New search strategies were derived in journal subsets formed by 2 approaches: random sampling of journals and top journals (having the most high-quality articles). The new strategies were tested in both the original large journal database and in a low-yielding journal (having few high-quality articles) subset. Results For treatment studies, if W was 10% or less for the lowest sensitivity among our existing search strategies, a subset of 15 randomly selected journals or 2 top journals were adequate for updating search strategies, based on each approach having at least 99 high-quality articles. The new strategies derived in 15 randomly selected journals or 2 top journals performed well in the original large journal database. Nevertheless, the new search strategies developed using the random sampling approach performed better than those developed using the top journal approach in a low-yielding journal subset. For studies of diagnosis and prognosis, no journal subset had enough high-quality articles to achieve the expected W (10%). Conclusion The approach of randomly sampling a small subset of journals that includes sufficient high-quality articles is an efficient way to update or create search strategies for high-quality articles on therapy in MEDLINE. The concentrations of diagnosis and prognosis articles are too low for this approach. PMID:18823538

  19. Quality assurance in the HIV/AIDS laboratory network of China.

    PubMed

    Jiang, Yan; Qiu, Maofeng; Zhang, Guiyun; Xing, Wenge; Xiao, Yao; Pan, Pinliang; Yao, Jun; Ou, Chin-Yih; Su, Xueli

    2010-12-01

    In 2009, there were 8273 local screening laboratories, 254 confirmatory laboratories, 35 provincial confirmatory central laboratories and 1 National AIDS Reference Laboratory (NARL) in China. These laboratories were located in Center for Disease Control and Prevention (CDC) facilities, hospitals, blood donation clinics, maternal and child health (MCH) hospitals and border health quarantine health-care facilities. The NARL and provincial laboratories provide quality assurance through technical, bio-safety and managerial training; periodic proficiency testing; on-site supervisory inspections; and commercial serologic kit evaluations. From 2002 to 2009, more than 220 million HIV antibody tests were performed at screening laboratories, and all reactive and indeterminate samples were confirmed at confirmatory laboratories. The use of highly technically complex tests, including CD4 cell enumeration, viral load, dried blood spot (DBS)-based early infant diagnosis (EID), drug resistance (DR) genotyping, HIV-1 subtyping and incidence assays, have increased in recent years and their performance quality is closely monitored. China has made significant progress in establishing a well-coordinated HIV laboratory network and QA systems. However, the coverage and intensity of HIV testing and quality assurance programmes need to be strengthened so as to ensure that more infected persons are diagnosed and that they receive timely prevention and treatment services.

  20. Ballast water as a vector of coral pathogens in the Gulf of Mexico: the case of the Cayo Arcas coral reef.

    PubMed

    Aguirre-Macedo, M Leopoldina; Vidal-Martinez, Victor M; Herrera-Silveira, Jorge A; Valdés-Lozano, David S; Herrera-Rodríguez, Miguel; Olvera-Novoa, Miguel A

    2008-09-01

    The discharge of nutrients, phytoplankton and pathogenic bacteria through ballast water may threaten the Cayo Arcas reef system. To assess this threat, the quality of ballast water and presence of coral reef pathogenic bacteria in 30 oil tankers loaded at the PEMEX Cayo Arcas crude oil terminal were determined. The water transported in the ships originated from coastal, oceanic or riverine regions. Statistical associations among quality parameters and bacteria were tested using redundancy analysis (RDA). In contrast with coastal or oceanic water, the riverine water had high concentrations of coliforms, including Vibrio cholerae 01 and, Serratia marcescens and Sphingomona spp., which are frequently associated with "white pox" and "white plague type II" coral diseases. There were also high nutrient concentrations and low water quality index values (WQI and TRIX). The presence of V. cholerae 01 highlights the need for testing ballast water coming from endemic regions into Mexican ports.

  1. A Study on the Quality and Identity of Brazilian Pampa Biome Honey: Evidences for Its Beneficial Effects against Oxidative Stress and Hyperglycemia

    PubMed Central

    Cruz, L. C.; Batista, J. E. S.; Zemolin, A. P. P.; Nunes, M. E. M.; Lippert, D. B.; Royes, L. F. F.; Soares, F. A.; Pereira, A. B.; Posser, T.; Franco, J. L.

    2014-01-01

    We characterized, for the first time, the quality and identity of Brazilian Pampa biome honey and its antioxidant properties in vitro (FRAP, DDPH and ABTS). The potential protective effect of honey against oxidative stress induced by iron (Fe) and paraquat, (PQ) in a Drosophila melanogaster model (in vivo) was also tested. The results indicated that all honey samples tested showed antioxidant activity in vitro. Flies treated with honey showed increased lifespan and were protected against oxidative stress induced by Fe and PQ. Despite the high concentration of sugars in honey (approximately 70–80%), our results demonstrate a hypoglycemic-like effect of honey in Drosophila. Thus, this study demonstrates the high quality of Brazilian Pampa biome honey as well as its significant antioxidant activity in vitro and in vivo, pointing to the potential use of this natural product as an alternative in the therapy of oxidative stress-associated diseases. PMID:26904632

  2. A Study on the Quality and Identity of Brazilian Pampa Biome Honey: Evidences for Its Beneficial Effects against Oxidative Stress and Hyperglycemia.

    PubMed

    Cruz, L C; Batista, J E S; Zemolin, A P P; Nunes, M E M; Lippert, D B; Royes, L F F; Soares, F A; Pereira, A B; Posser, T; Franco, J L

    2014-01-01

    We characterized, for the first time, the quality and identity of Brazilian Pampa biome honey and its antioxidant properties in vitro (FRAP, DDPH and ABTS). The potential protective effect of honey against oxidative stress induced by iron (Fe) and paraquat, (PQ) in a Drosophila melanogaster model (in vivo) was also tested. The results indicated that all honey samples tested showed antioxidant activity in vitro. Flies treated with honey showed increased lifespan and were protected against oxidative stress induced by Fe and PQ. Despite the high concentration of sugars in honey (approximately 70-80%), our results demonstrate a hypoglycemic-like effect of honey in Drosophila. Thus, this study demonstrates the high quality of Brazilian Pampa biome honey as well as its significant antioxidant activity in vitro and in vivo, pointing to the potential use of this natural product as an alternative in the therapy of oxidative stress-associated diseases.

  3. Competency Tests and Graduation Requirements. Second Edition.

    ERIC Educational Resources Information Center

    Keefe, James W.

    Interest in applied performance testing and concern about the quality of the high school diploma are finding a common ground: graduation requirements. A competency is a complex capability applicable in real life situations, and can be used as program objectives in a competency-based, criterion-referenced program. In such a program, applied…

  4. Primary care spirometry: test quality and the feasibility and usefulness of specialist reporting

    PubMed Central

    White, Patrick; Wong, Wun; Fleming, Tracey; Gray, Barry

    2007-01-01

    Background Provision of spirometry for chronic obstructive pulmonary disease (COPD) is a new requirement in primary care. Effective spirometry requires that tests and interpretations meet international criteria. Aim To assess the feasibility and usefulness of remote specialist reporting of primary care spirometry. Design of study Comparison of reporting by primary care clinicians and respiratory specialists of consecutive primary care spirometry tests. Setting South London primary care teams with patient lists ≥6000. Method Feasibility of remote reporting of spirometry was assessed by the frequency of electronic mailing of tests. Usefulness of remote reporting was defined by the frequency that specialist reports made a clinically significant addition. Usefulness was assessed by measuring agreement (κ) between primary care reports and those of specialists. Clinically significant disagreements were analysed with respect to test quality, diagnosis, and severity. Results Six practices emailed 312 tests over 3 months. Forty-nine tests sent without indices or curves (flow volume and time volume) were excluded. Mean age of patients tested was 65 years and 52% were female. Mean predicted forced expiratory volume in the first second (FEV1) was 69%. Clinically significant disagreements were identified in the interpretation of acceptability (quality) of 67/212 (32%) tests (κ = 0.07; 95% confidence interval [CI] = 0 to 0.24), of diagnosis in 49/168 (29%) tests (κ = 0.39; 95% CI = 0.25 to 0.55), and of severity in 62/191 (32%) tests (κ = 0.53; 95% CI = 0.43 to 0.63). Conclusion Remote reporting of primary care spirometry was feasible. Its usefulness was confirmed by the high rate of additional clinically significant information to the reports of primary care clinicians. The quality of primary care spirometry was so unsatisfactory that remote reporting of tests may be a means of establishing adequate spirometry. PMID:17761057

  5. Technology development of fabrication techniques for advanced solar dynamic concentrators

    NASA Technical Reports Server (NTRS)

    Richter, Scott W.

    1991-01-01

    The objective of the advanced concentrator program is to develop the technology that will lead to lightweight, highly reflective, accurate, scaleable, and long lived space solar dynamic concentrators. The advanced concentrator program encompasses new and innovative concepts, fabrication techniques, materials selection, and simulated space environmental testing. Fabrication techniques include methods of fabricating the substrates and coating substrate surfaces to produce high quality optical surfaces, acceptable for further coating with vapor deposited optical films. The selected materials to obtain a high quality optical surface include microsheet glass and Eccocoat EP-3 epoxy, with DC-93-500 selected as a candidate silicone adhesive and levelizing layer. The following procedures are defined: cutting, cleaning, forming, and bonding microsheet glass. Procedures are also defined for surface cleaning, and EP-3 epoxy application. The results and analyses from atomic oxygen and thermal cycling tests are used to determine the effects of orbital conditions in a space environment.

  6. Symptom frequency of children with cancer and parent quality of life in Turkey.

    PubMed

    Kudubes, Asli Akdeniz; Bektas, Murat; Ugur, Ozlem

    2014-01-01

    This research was planned with the aim of determining the effect of symptom frequency of children with cancer on the quality of life of their parents. In gathering the research data, the Child and Parent Information Form, the Symptom Evaluation Form and the Family Version of Life Quality Scale in Cancer Patients were used. Evaluation was made by using percentage calculations, Kruskal Wallis test, Bonferroni adjusted t-test and Bonferroni adjusted Mann-Whitney U test. The significance level was accepted as 0.005. Some 37.6% of the participant children were female and 62.4% were male, with an average age of 10.2 ± 4.5. While 41.0% were newly diagnosed, 46.2% were in remission and 12.8% was in relapse. Highly significant differences were detected according to the symptom frequency with parent physical and psychological health, social anxiety, and spiritual wellness sub-dimensions, as well as total point averages. It is thought that following up the symptoms that might develop depending on cancer diagnosis and treatment and implementing nursing initiatives aimed at reducing the symptoms, knowing the importance of life quality, maintaining measures aimed at life quality and planning initiatives to increase the life quality will play a key role in maintaining and developing the health of Turkish paediatric oncology patients and their parents.

  7. Near-infrared Spectroscopy in the Brewing Industry.

    PubMed

    Sileoni, Valeria; Marconi, Ombretta; Perretti, Giuseppe

    2015-01-01

    This article offers an exhaustive description of the use of Near-Infrared (NIR) Spectroscopy in the brewing industry. This technique is widely used for quality control testing of raw materials, intermediates, and finished products, as well as process monitoring during malting and brewing. In particular, most of the reviewed works focus on the assessment of barley properties, aimed at quickly selecting the best barley varieties in order to produce a high-quality malt leading to high-quality beer. Various works concerning the use of NIR in the evaluation of raw materials, such as barley, malt, hop, and yeast, are also summarized here. The implementation of NIR sensors for the control of malting and brewing processes is also highlighted, as well as the use of NIR for quality assessment of the final product.

  8. [Testing of medicinal products produced from pooled plasma].

    PubMed

    Unkelbach, U; Hunfeld, A; Breitner-Ruddock, S

    2014-10-01

    Medicinal products produced from human plasma fall under the administrative batch release procedure of the competent authority. In Germany, this has been carried out since 1995 by the Paul Ehrlich Institute (PEI), the responsible state control agency for blood products. Medicinal products released for the European and national market are tested for quality, efficacy and safety. Experimental testing of the final product and the starting materials, the plasma pools, as well as control of the production documentation guarantee a constantly high product safety. In the 28,000 batches tested since the beginning of the state controlled batch release testing of these blood products at the PEI, there has been no transmission of infectious viruses (HIV, HBV and HCV) to any patient. The batch release has made a contribution to the improvement of product quality. This procedure is still an important tool to ensure safety of blood products. The PEI is integrated in the batch release network of the European Directorate for the Quality of Medicines & Health Care (EDQM) in Strasbourg. Regulations and guidelines for official control authority batch release (OCABR) ensure harmonized procedures for mutual recognition of batch release on the European level. The EU certificates and German national certificates are requested and accepted in over 70 countries worldwide. Experimental testing in the EU and the requisite certificates have developed into a seal of quality for the world market.

  9. High quality diabetes care: testing the effectiveness of strategies of regional implementation teams.

    PubMed

    Drach-Zahavy, Anat; Shadmi, Efrat; Freund, Anat; Goldfracht, Margalit

    2009-01-01

    The purpose of this article is to identify and test the effectiveness of work strategies employed by regional implementation teams to attain high quality care for diabetes patients. The study was conducted in a major health maintenance organization (HMO) that provides care for 70 per cent of Israel's diabetes patients. A sequential mixed model design, combining qualitative and quantitative methods was employed. In-depth interviews were conducted with members of six regional implementation teams, each responsible for the care of 25,000-34,000 diabetic patients. Content analysis of the interviews revealed that teams employed four key strategies: task-interdependence, goal-interdependence, reliance on top-down standardised processes and team-learning. These strategies were used to predict the mean percentage performance of eight evidence-based indicators of diabetes care: percentage of patients with HbA1c < 7 per cent, blood pressure < or = 130/80 and cholesterol < or = 100; and performance of: HbA1c tests, LDL cholesterol tests, blood pressure measurements, urine protein tests, and ophthalmic examinations. Teams were found to vary in their use of the four strategies. Mixed linear models analysis indicated that type of indicator (simple process, compound process, and outcome) and goal interdependence were significantly linked to team effectiveness. For simple-process indicators, reliance on top-down standardised processes led to team effectiveness, but for outcome measures this strategy was ineffective, and even counter-effective. For outcome measures, team-learning was more beneficial. The findings have implications for the management of chronic diseases. The advantage of allowing team members flexibility in the choice of the best work strategy to attain high quality diabetes care is attested.

  10. Preparation and analysis of zero gases for the measurement of trace VOCs in air monitoring

    NASA Astrophysics Data System (ADS)

    Englert, Jennifer; Claude, Anja; Demichelis, Alessia; Persijn, Stefan; Baldan, Annarita; Li, Jianrong; Plass-Duelmer, Christian; Michl, Katja; Tensing, Erasmus; Wortman, Rina; Ghorafi, Yousra; Lecuna, Maricarmen; Sassi, Guido; Sassi, Maria Paola; Kubistin, Dagmar

    2018-06-01

    Air quality observations are performed globally to monitor the status of the atmosphere and its level of pollution and to assess mitigation strategies. Regulations of air quality monitoring programmes in various countries demand high-precision measurements for harmful substances often at low trace concentrations. These requirements can only be achieved by using high-quality calibration gases including high-purity zero gas. For volatile organic compound (VOC) observations, zero gas is defined as being hydrocarbon-free and can be, for example, purified air, nitrogen or helium. It is essential for the characterisation of the measurement devices and procedures, for instrument operation as well as for calibrations. Two commercial and one self-built gas purifiers were tested for their VOC removal efficiency following a standardised procedure. The tested gas purifiers included one adsorption cartridge with an inorganic media and two types of metal catalysts. A large range of VOCs were investigated, including the most abundant species typically measured at air monitoring stations. Both catalysts were able to remove a large range of VOCs whilst the tested adsorption cartridge was not suitable to remove light compounds up to C4. Memory effects occurred for the adsorption cartridge when exposed to higher concentration. This study emphasises the importance of explicitly examining a gas purifier for its intended application before applying it in the field.

  11. Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?

    PubMed Central

    Chouler, Jon; Di Lorenzo, Mirella

    2015-01-01

    The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries. PMID:26193327

  12. Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?

    PubMed

    Chouler, Jon; Di Lorenzo, Mirella

    2015-07-16

    The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries.

  13. Effect of home care service on the quality of life in patients with gynecological cancer.

    PubMed

    Aktas, Demet; Terzioglu, Fusun

    2015-01-01

    The purpose of the research was to determine the effect of home care service on the quality of life in patients with gynecological cancer. This randomized case control study was carried out in a womans hospital between September 2011 and February 2012. Women undergoing gynecological cancer treatment were separated into intervention and control groups, of 35 patients each. The intervention group was provided with nursing care service through hospital and home visits (1st, 12th weeks) within the framework of a specifically developed nursing care plan. The control group was monitored without any intervention through the hospital routine protocols (1st, 12th weeks). Data were collected using An Interview Form, Home Visit Monitoring Form and Quality of Life Scale/Cancer Survivors. Effects of home care service on the quality of life in gynecological cancer patients were investigated using chi-square tests, McNemar's test, independent t-test and ANOVA. This study found that the intervention group receiving home care service had a moderately high quality of life (average mean: 6.01±0.64), while the control group had comparatively lower quality (average mean: 4.35±0.79) within the 12 week post- discharge period (p<0.05). This study found home care services to be efficient in improving the quality of life in patients with gynecological cancer.

  14. Measurement of the quality factor of a new low-frequency differential accelerometer for testing the equivalence principle.

    PubMed

    Iafolla, V; Lefevre, C; Fiorenza, E; Santoli, F; Nozzoli, S; Magnafico, C; Lucente, M; Lucchesi, D; Peron, R; Shapiro, I I; Glashow, S; Lorenzini, E C

    2014-01-01

    A cryogenic differential accelerometer has been developed to test the weak equivalence principle to a few parts in 10(15) within the framework of the general relativity accuracy test in an Einstein elevator experiment. The prototype sensor was designed to identify, address, and solve the major issues associated with various aspects of the experiment. This paper illustrates the measurements conducted on this prototype sensor to attain a high quality factor (Q ∼ 10(5)) at low frequencies (<20 Hz). Such a value is necessary for reducing the Brownian noise to match the target acceleration noise of 10(-14) g/√Hz, hence providing the desired experimental accuracy.

  15. Development of quality standards for inclusion of high recycled asphalt pavement content in asphalt mixtures - phase II, [tech brief].

    DOT National Transportation Integrated Search

    2015-03-01

    The objective of this research is to 1) build a test section utilizing HMA : mix designs with up to 40% RAP materials, 2) evaluate the moisture : sensitivity of High-RAP mixtures, 3) characterize the low-temperature : fracture behavior of High-RAP mi...

  16. Consumers' quality perception of national branded, national store branded, and imported store branded beef.

    PubMed

    Banović, Marija; Grunert, Klaus G; Barreira, Maria Madalena; Fontes, Magda Aguiar

    2010-01-01

    This study investigated the differences in the consumers' quality perception of national branded, national store branded, and imported store branded beef. Partial Least Squares analysis is used for modelling the quality perception process. Results show that consumers perceived national branded Carnalentejana beef, as better on all quality cues and quality aspects than the other two store branded beefs. Preference for Carnalentejana beef stayed highly consistent even after the blind test, where consumers differentiated this beef from the other two beef brands on all sensory dimensions: taste, tenderness, and juiciness, and chose it as the preferred one. Consumers utilized more perceived intrinsic cues to infer expected eating quality of store branded beefs.

  17. Flexible sigmoidoscopy versus faecal occult blood testing for colorectal cancer screening in asymptomatic individuals.

    PubMed

    Holme, Øyvind; Bretthauer, Michael; Fretheim, Atle; Odgaard-Jensen, Jan; Hoff, Geir

    2013-10-01

    Colorectal cancer is the third most frequent cancer in the world. As the sojourn time for this cancer is several years and a good prognosis is associated with early stage diagnosis, screening has been implemented in a number of countries. Both screening with faecal occult blood test and flexible sigmoidoscopy have been shown to reduce mortality from colorectal cancer in randomised controlled trials. The comparative effectiveness of these tests on colorectal cancer mortality has, however, never been evaluated, and controversies exist over which test to choose. To compare the effectiveness of screening for colorectal cancer with flexible sigmoidoscopy to faecal occult blood testing. We searched MEDLINE and EMBASE (November 16, 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 11) and reference lists for eligible studies. Randomised controlled trials comparing screening with flexible sigmoidoscopy or faecal occult blood testing to each other or to no screening. Only studies reporting mortality from colorectal cancer were included. Faecal occult blood testing had to be repeated (annually or biennially). Data retrieval and assessment of risk of bias were performed independently by two review authors. Standard meta-analyses using a random-effects model were conducted for flexible sigmoidoscopy and faecal occult blood testing (FOBT) separately and we calculated relative risks with 95% confidence intervals (CI). We used a Bayesian approach (a contrast-based network meta-analysis method) for indirect analyses and presented the results as posterior median relative risk with 95% credibility intervals. We assessed the quality of evidence using GRADE. We identified nine studies comprising 338,467 individuals randomised to screening and 405,919 individuals to the control groups. Five studies compared flexible sigmoidoscopy to no screening and four studies compared repetitive guaiac-based FOBT (annually and biennially) to no screening. We did not consider that study risk of bias reduced our confidence in our results. We did not identify any studies comparing the two screening methods directly. When compared with no screening, colorectal cancer mortality was lower with flexible sigmoidoscopy (relative risk 0.72; 95% CI 0.65 to 0.79, high quality evidence) and FOBT (relative risk 0.86; 95% CI 0.80 to 0.92, high quality evidence). In the analyses based on indirect comparison of the two screening methods, the relative risk of dying from colorectal cancer was 0.85 (95% credibility interval 0.72 to 1.01, low quality evidence) for flexible sigmoidoscopy screening compared to FOBT. No complications occurred after the FOBT test itself, but 0.03% of participants suffered a major complication after follow-up. Among more than 60,000 flexible sigmoidoscopy screening procedures and almost 6000 work-up colonoscopies, a major complication was recorded in 0.08% of participants. Adverse event data should be interpreted with caution as the reporting of adverse effects was incomplete. There is high quality evidence that both flexible sigmoidoscopy and faecal occult blood testing reduce colorectal cancer mortality when applied as screening tools. There is low quality indirect evidence that screening with either approach reduces colorectal cancer deaths more than the other. Major complications associated with screening require validation from studies with more complete reporting of harms

  18. Forecasting of high voltage insulation performance: Testing of recommended potting materials and of capacitors

    NASA Technical Reports Server (NTRS)

    Bever, R. S.

    1984-01-01

    Nondestructive high voltage test techniques (mostly electrical methods) are studied to prevent total or catastrophic breakdown of insulation systems under applied high voltage in space. Emphasis is on the phenomenon of partial breakdown or partial discharge (P.D.) as a symptom of insulation quality, notably partial discharge testing under D.C. applied voltage. Many of the electronic parts and high voltage instruments in space experience D.C. applied stress in service, and application of A.C. voltage to any portion thereof would be prohibited. Suggestions include: investigation of the ramp test method for D.C. partial discharge measurements; testing of actual flight-type insulation specimen; perfect plotting resin samples with controlled defects for test; several types of plotting resins and recommendations of the better ones from the electrical characteristics; thermal and elastic properties are also considered; testing of commercial capaciters; and approximate acceptance/rejection/rerating criteria for sample test elements for space use, based on D.C. partial discharge.

  19. How bio-questionable are the different recombinant human erythropoietin copy products in Thailand?

    PubMed

    Halim, Liem Andhyk; Brinks, Vera; Jiskoot, Wim; Romeijn, Stefan; Praditpornsilpa, Kearkiat; Assawamakin, Anunchai; Schellekens, Huub

    2014-05-01

    The high prevalence of pure red cell aplasia in Thailand has been associated with the sharp increase in number of recombinant human erythropoietin (rhEPO) copy products, based on a classical generic regulatory pathway, which have entered the market. This study aims to assess the quality of rhEPO copy products being used in Thailand. Twelve rhEPO copy products were purchased from pharmacies in Thailand, shipped under controlled cold chain conditions to the Netherlands and characterized using (1) high performance size-exclusion chromatography, (2) asymmetrical flow field-flow fractionation, (3) sodium dodecyl sulfate polyacrylamide gel electrophoresis in combination with (4) Western blotting and additionally tested for (5) host cell protein impurities as well as (6) endotoxin contamination. Some of the tested rhEPO copy products showed high aggregate levels and contained a substantial amount of protein fragments. Also, one of rhEPO copy products had a high endotoxin level, exceeding the FDA limit. Our observations show that some of the tested copy products on the Thai market differ significantly from the originator rhEPO product, Epogen®. This comparison study supports a link between the quality attributes of copy rhEPO products and their immunogenicity.

  20. Measurement properties of maximal cardiopulmonary exercise tests protocols in persons after stroke: A systematic review.

    PubMed

    Wittink, Harriet; Verschuren, Olaf; Terwee, Caroline; de Groot, Janke; Kwakkel, Gert; van de Port, Ingrid

    2017-11-21

    To systematically review and critically appraise the literature on measurement properties of cardiopulmonary exercise test protocols for measuring aerobic capacity, VO2max, in persons after stroke. PubMed, Embase and Cinahl were searched from inception up to 15 June 2016. A total of 9 studies were identified reporting on 9 different cardiopulmonary exercise test protocols. VO2max measured with cardiopulmonary exercise test and open spirometry was the construct of interest. The target population was adult persons after stroke. We included all studies that evaluated reliability, measurement error, criterion validity, content validity, hypothesis testing and/or responsiveness of cardiopulmonary exercise test protocols. Two researchers independently screened the literature, assessed methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and extracted data on measurement properties of cardiopulmonary exercise test protocols. Most studies reported on only one measurement property. Best-evidence synthesis was derived taking into account the methodological quality of the studies, the results and the consistency of the results. No judgement could be made on which protocol is "best" for measuring VO2max in persons after stroke due to lack of high-quality studies on the measurement properties of the cardiopulmonary exercise test.

  1. 1 Patient acceptability and feasibility of HIV testing in emergency departments in the UK - a systematic review and meta-analysis.

    PubMed

    Lungu, Nicola

    2017-12-01

    NICE 2016 HIV testing guidelines now include the recommendation to offer HIV testing in Emergency Departments, in areas of high prevalence, 1 to everyone who is undergoing blood tests. 23% of England's local authorities are areas of high HIV prevalence (>2/1000) and are therefore eligible. 2 So far very few Emergency Departments have implemented routine HIV testing. This systematic review assesses evidence for two implementation considerations: patient acceptability (how likely a patient will accept an HIV test when offered in an Emergency Department), and feasibility, which incorporates staff training and willingness, and department capacity, (how likely Emergency Department staff will offer an HIV test to an eligible patient), both measured by surrogate quantitative markers. Three medical databases were systematically searched for reports of non-targeted HIV testing in UK Emergency Departments. A total of 1584 unique papers were found, 9 full text articles were critically appraised, and 7 studies included in meta-analysis. There is a combined patient sample of 1 01 975. The primary outcome, patient acceptability of HIV testing in Emergency Departments (number of patients accepting an HIV test, as a proportion of those offered) is 54.1% (CI 40.1, 68.2). Feasibility (number of tests offered, as a proportion of eligible patients) is 36.2% (CI 9.8, 62.4). For an Emergency Department considering introducing routine HIV testing, this review suggests an opt-out publicity-lead strategy. Utilising oral fluid and blood tests would lead to the greatest proportion of eligible patients accepting an HIV test. For individual staff who are consenting patients for HIV testing, it may be encouraging to know that there is >50% chance the patient will accept an offer of testing.emermed;34/12/A860-a/T1F1T1Table 1Summary table of data extracted from final 7 studies, with calculated acceptability and feasibility if appropriate, and GRADE score. Studies listed in chronological order of data collection. GRADE working group evidence grades: 4= high quality, 3= moderate quality, 2= low quality, 1 or below = very low quality. (*study conclusion reports this figure is inaccurate)emermed;34/12/A860-a/F1F2F1Figure 1Patients accepting HIV tests, and being offered HIV tests, as a proportion of the eligible sample REFERENCES: National Institute for Health and Care Excellence, Public Health England. HIV testing: Increasing uptake among people who may have undiagnosed HIV . 2016 1 December 2016.Public Health England. HIV prevalence by Local Authority of residence to end December 2015 . Table No.1: 2016. Public Health Engand; 2016. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Avionics Integrity Program (AVIP). Volume 1. Procurement Phase Issues - Design, Manufacturing, and Integration

    DTIC Science & Technology

    1984-03-01

    Engineering initiative to develop an orderly plan and procedure to assure that USAF acquire reliable, high quality, supportable avionics with a higher avail...susceptibility te~t~ (radiated and conducted), and emission of radio frequency energy tests."l6) Other electrical stresses can include over/under voltage...jo ints, poor welds, and dielectric defects. Also, instruments with components unable to endu very high temperatures can be safely tested. 1-19

  3. Improving the quality of parameter estimates obtained from slug tests

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Liu, W.

    1996-01-01

    The slug test is one of the most commonly used field methods for obtaining in situ estimates of hydraulic conductivity. Despite its prevalence, this method has received criticism from many quarters in the ground-water community. This criticism emphasizes the poor quality of the estimated parameters, a condition that is primarily a product of the somewhat casual approach that is often employed in slug tests. Recently, the Kansas Geological Survey (KGS) has pursued research directed it improving methods for the performance and analysis of slug tests. Based on extensive theoretical and field research, a series of guidelines have been proposed that should enable the quality of parameter estimates to be improved. The most significant of these guidelines are: (1) three or more slug tests should be performed at each well during a given test period; (2) two or more different initial displacements (Ho) should be used at each well during a test period; (3) the method used to initiate a test should enable the slug to be introduced in a near-instantaneous manner and should allow a good estimate of Ho to be obtained; (4) data-acquisition equipment that enables a large quantity of high quality data to be collected should be employed; (5) if an estimate of the storage parameter is needed, an observation well other than the test well should be employed; (6) the method chosen for analysis of the slug-test data should be appropriate for site conditions; (7) use of pre- and post-analysis plots should be an integral component of the analysis procedure, and (8) appropriate well construction parameters should be employed. Data from slug tests performed at a number of KGS field sites demonstrate the importance of these guidelines.

  4. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories

    PubMed Central

    Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N’Faly; Martel, Lise D.; Dahourou, Anicet George

    2017-01-01

    Background Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Methods and findings Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. Conclusions The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation. PMID:29190713

  5. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    PubMed

    VanSteelandt, Amanda; Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N'Faly; Martel, Lise D; Dahourou, Anicet George

    2017-01-01

    Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  6. Bone quality assessment for total hip arthroplasty with intraoperative trabecular torque measurements.

    PubMed

    Klotz, Matthias C M; Beckmann, Nicholas A; Bitsch, Rudi G; Seebach, Elisabeth; Reiner, Tobias; Jäger, Sebastian

    2014-11-13

    In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product-moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson's product-moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.

  7. Design and Testing of a Tool for Evaluating the Quality of Diabetes Consumer-Information Web Sites

    PubMed Central

    Steinwachs, Donald; Rubin, Haya R

    2003-01-01

    Background Most existing tools for measuring the quality of Internet health information focus almost exclusively on structural criteria or other proxies for quality information rather than evaluating actual accuracy and comprehensiveness. Objective This research sought to develop a new performance-measurement tool for evaluating the quality of Internet health information, test the validity and reliability of the tool, and assess the variability in diabetes Web site quality. Methods An objective, systematic tool was developed to evaluate Internet diabetes information based on a quality-of-care measurement framework. The principal investigator developed an abstraction tool and trained an external reviewer on its use. The tool included 7 structural measures and 34 performance measures created by using evidence-based practice guidelines and experts' judgments of accuracy and comprehensiveness. Results Substantial variation existed in all categories, with overall scores following a normal distribution and ranging from 15% to 95% (mean was 50% and median was 51%). Lin's concordance correlation coefficient to assess agreement between raters produced a rho of 0.761 (Pearson's r of 0.769), suggesting moderate to high agreement. The average agreement between raters for the performance measures was 0.80. Conclusions Diabetes Web site quality varies widely. Alpha testing of this new tool suggests that it could become a reliable and valid method for evaluating the quality of Internet health sites. Such an instrument could help lay people distinguish between beneficial and misleading information. PMID:14713658

  8. Characteristics of iron corrosion scales and water quality variations in drinking water distribution systems of different pipe materials.

    PubMed

    Li, Manjie; Liu, Zhaowei; Chen, Yongcan; Hai, Yang

    2016-12-01

    Interaction between old, corroded iron pipe surfaces and bulk water is crucial to the water quality protection in drinking water distribution systems (WDS). Iron released from corrosion products will deteriorate water quality and lead to red water. This study attempted to understand the effects of pipe materials on corrosion scale characteristics and water quality variations in WDS. A more than 20-year-old hybrid pipe section assembled of unlined cast iron pipe (UCIP) and galvanized iron pipe (GIP) was selected to investigate physico-chemical characteristics of corrosion scales and their effects on water quality variations. Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Inductively Coupled Plasma (ICP) and X-ray Diffraction (XRD) were used to analyze micromorphology and chemical composition of corrosion scales. In bench testing, water quality parameters, such as pH, dissolved oxygen (DO), oxidation reduction potential (ORP), alkalinity, conductivity, turbidity, color, Fe 2+ , Fe 3+ and Zn 2+ , were determined. Scale analysis and bench-scale testing results demonstrated a significant effect of pipe materials on scale characteristics and thereby water quality variations in WDS. Characteristics of corrosion scales sampled from different pipe segments show obvious differences, both in physical and chemical aspects. Corrosion scales were found highly amorphous. Thanks to the protection of zinc coatings, GIP system was identified as the best water quality stability, in spite of high zinc release potential. It is deduced that the complicated composition of corrosion scales and structural break by the weld result in the diminished water quality stability in HP system. Measurement results showed that iron is released mainly in ferric particulate form. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Metrologies for quantitative nanomechanical testing and quality control in semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Pratt, Jon R.; Kramar, John A.; Newell, David B.; Smith, Douglas T.

    2005-05-01

    If nanomechanical testing is to evolve into a tool for process and quality control in semiconductor fabrication, great advances in throughput, repeatability, and accuracy of the associated instruments and measurements will be required. A recent grant awarded by the NIST Advanced Technology Program seeks to address the throughput issue by developing a high-speed AFM-based platform for quantitative nanomechanical measurements. The following paper speaks to the issue of quantitative accuracy by presenting an overview of various standards and techniques under development at NIST and other national metrology institutes (NMIs) that can provide a metrological basis for nanomechanical testing. The infrastructure we describe places firm emphasis on traceability to the International System of Units, paving the way for truly quantitative, rather than qualitative, physical property testing.

  10. Evaluation of English Achievement Test: A Comparison between High and Low Achievers amongst Selected Elementary School Students of Pakistan

    ERIC Educational Resources Information Center

    Haider, Zubair; Latif, Farah; Akhtar, Samina; Mushtaq, Maria

    2012-01-01

    Validity, reliability and item analysis are critical to the process of evaluating the quality of an educational measurement. The present study evaluates the quality of an assessment constructed to measure elementary school student's achievement in English. In this study, the survey model of descriptive research was used as a research method.…

  11. Effectiveness of the Hydrogen Sulfide Test as a Water Quality Indicator for Diarrhea Risk in Rural Bangladesh

    PubMed Central

    Islam, Mahfuza; Ercumen, Ayse; Naser, Abu Mohd; Unicomb, Leanne; Rahman, Mahbubur; Arnold, Benjamin F.; Colford, Jr., John M.; Luby, Stephen P.

    2017-01-01

    Abstract. Microbiological water quality is usually assessed by the identification of Escherichia coli (E. coli), a fecal indicator. The hydrogen sulfide (H2S) test is an inexpensive, easy-to-use, and portable alternative field-based water quality test. Our study evaluated the H2S test’s effectiveness as a water quality indicator for diarrhea risk. Field workers collected stored drinking water samples for H2S analysis and detection of E. coli by membrane filtration and measured caregiver-reported diarrhea among children < 5 years in the same households 1 month later. We assessed the association between the H2S test (incubated for 24 hours and 48 hours) and diarrhea prevalence, with 2-day and 7-day symptom recall periods (N = 1,348). We determined the sensitivity, specificity, and positive and negative predictive value (PPV, NPV) of the H2S test compared with E. coli (N = 525). Controlling for potentially confounding covariates, H2S-positive water (at 24 or 48 hours) was not associated with 2-day diarrhea prevalence (24-hour prevalence ratio [PR] = 1.03, 95% confidence interval [CI]: 0.63–1.69; 48-hour PR = 0.89, 95% CI: 0.58–1.38) or 7-day diarrhea prevalence (24-hour PR = 1.17, 95% CI: 0.76–1.78; 48-hour PR = 1.21, 95% CI: 0.81–1.80). The sensitivity, PPV, and NPV of the H2S test was significantly higher when the H2S test was incubated for 48 versus 24 hours whereas specificity showed the opposite trend. H2S test sensitivity, PPV, and NPV increased with increasing E. coli levels, consistent with previous evidence that the H2S test is a useful water quality tool in high-contamination settings. However, our results suggest that the H2S test is not an effective indicator for waterborne diarrhea. PMID:29141754

  12. Ground-to-Flight Handling Qualities Comparisons for a High Performance Airplane

    NASA Technical Reports Server (NTRS)

    Brandon, Jay M.; Glaab, Louis J.; Brown, Philip W.; Phillips, Michael R.

    1995-01-01

    A flight test program was conducted in conjunction with a ground-based piloted simulation study to enable a comparison of handling qualities ratings for a variety of maneuvers between flight and simulation of a modern high performance airplane. Specific objectives included an evaluation of pilot-induced oscillation (PIO) tendencies and a determination of maneuver types which result in either good or poor ground-to-flight pilot handling qualities ratings. A General Dynamics F-16XL aircraft was used for the flight evaluations, and the NASA Langley Differential Maneuvering Simulator was employed for the ground based evaluations. Two NASA research pilots evaluated both the airplane and simulator characteristics using tasks developed in the simulator. Simulator and flight tests were all conducted within approximately a one month time frame. Maneuvers included numerous fine tracking evaluations at various angles of attack, load factors and speed ranges, gross acquisitions involving longitudinal and lateral maneuvering, roll angle captures, and an ILS task with a sidestep to landing. Overall results showed generally good correlation between ground and flight for PIO tendencies and general handling qualities comments. Differences in pilot technique used in simulator evaluations and effects of airplane accelerations and motions are illustrated.

  13. Trait-specific responses of wild bee communities to landscape composition, configuration and local factors.

    PubMed

    Hopfenmüller, Sebastian; Steffan-Dewenter, Ingolf; Holzschuh, Andrea

    2014-01-01

    Land-use intensification and loss of semi-natural habitats have induced a severe decline of bee diversity in agricultural landscapes. Semi-natural habitats like calcareous grasslands are among the most important bee habitats in central Europe, but they are threatened by decreasing habitat area and quality, and by homogenization of the surrounding landscape affecting both landscape composition and configuration. In this study we tested the importance of habitat area, quality and connectivity as well as landscape composition and configuration on wild bees in calcareous grasslands. We made detailed trait-specific analyses as bees with different traits might differ in their response to the tested factors. Species richness and abundance of wild bees were surveyed on 23 calcareous grassland patches in Southern Germany with independent gradients in local and landscape factors. Total wild bee richness was positively affected by complex landscape configuration, large habitat area and high habitat quality (i.e. steep slopes). Cuckoo bee richness was positively affected by complex landscape configuration and large habitat area whereas habitat specialists were only affected by the local factors habitat area and habitat quality. Small social generalists were positively influenced by habitat area whereas large social generalists (bumblebees) were positively affected by landscape composition (high percentage of semi-natural habitats). Our results emphasize a strong dependence of habitat specialists on local habitat characteristics, whereas cuckoo bees and bumblebees are more likely affected by the surrounding landscape. We conclude that a combination of large high-quality patches and heterogeneous landscapes maintains high bee species richness and communities with diverse trait composition. Such diverse communities might stabilize pollination services provided to crops and wild plants on local and landscape scales.

  14. Trait-Specific Responses of Wild Bee Communities to Landscape Composition, Configuration and Local Factors

    PubMed Central

    Hopfenmüller, Sebastian; Steffan-Dewenter, Ingolf; Holzschuh, Andrea

    2014-01-01

    Land-use intensification and loss of semi-natural habitats have induced a severe decline of bee diversity in agricultural landscapes. Semi-natural habitats like calcareous grasslands are among the most important bee habitats in central Europe, but they are threatened by decreasing habitat area and quality, and by homogenization of the surrounding landscape affecting both landscape composition and configuration. In this study we tested the importance of habitat area, quality and connectivity as well as landscape composition and configuration on wild bees in calcareous grasslands. We made detailed trait-specific analyses as bees with different traits might differ in their response to the tested factors. Species richness and abundance of wild bees were surveyed on 23 calcareous grassland patches in Southern Germany with independent gradients in local and landscape factors. Total wild bee richness was positively affected by complex landscape configuration, large habitat area and high habitat quality (i.e. steep slopes). Cuckoo bee richness was positively affected by complex landscape configuration and large habitat area whereas habitat specialists were only affected by the local factors habitat area and habitat quality. Small social generalists were positively influenced by habitat area whereas large social generalists (bumblebees) were positively affected by landscape composition (high percentage of semi-natural habitats). Our results emphasize a strong dependence of habitat specialists on local habitat characteristics, whereas cuckoo bees and bumblebees are more likely affected by the surrounding landscape. We conclude that a combination of large high-quality patches and heterogeneous landscapes maintains high bee species richness and communities with diverse trait composition. Such diverse communities might stabilize pollination services provided to crops and wild plants on local and landscape scales. PMID:25137311

  15. Performance prediction of optical image stabilizer using SVM for shaker-free production line

    NASA Astrophysics Data System (ADS)

    Kim, HyungKwan; Lee, JungHyun; Hyun, JinWook; Lim, Haekeun; Kim, GyuYeol; Moon, HyukSoo

    2016-04-01

    Recent smartphones adapt the camera module with optical image stabilizer(OIS) to enhance imaging quality in handshaking conditions. However, compared to the non-OIS camera module, the cost for implementing the OIS module is still high. One reason is that the production line for the OIS camera module requires a highly precise shaker table in final test process, which increases the unit cost of the production. In this paper, we propose a framework for the OIS quality prediction that is trained with the support vector machine and following module characterizing features : noise spectral density of gyroscope, optically measured linearity and cross-axis movement of hall and actuator. The classifier was tested on an actual production line and resulted in 88% accuracy of recall rate.

  16. Verification and Validation in a Rapid Software Development Process

    NASA Technical Reports Server (NTRS)

    Callahan, John R.; Easterbrook, Steve M.

    1997-01-01

    The high cost of software production is driving development organizations to adopt more automated design and analysis methods such as rapid prototyping, computer-aided software engineering (CASE) tools, and high-level code generators. Even developers of safety-critical software system have adopted many of these new methods while striving to achieve high levels Of quality and reliability. While these new methods may enhance productivity and quality in many cases, we examine some of the risks involved in the use of new methods in safety-critical contexts. We examine a case study involving the use of a CASE tool that automatically generates code from high-level system designs. We show that while high-level testing on the system structure is highly desirable, significant risks exist in the automatically generated code and in re-validating releases of the generated code after subsequent design changes. We identify these risks and suggest process improvements that retain the advantages of rapid, automated development methods within the quality and reliability contexts of safety-critical projects.

  17. Measuring the qualities of nurses: development and testing of the Qualities of Nurses Scale.

    PubMed

    Johnson, Maree; Cowin, Leanne

    2013-01-01

    This paper reports on the creation, development and testing of a new instrument to measure qualities of nurses, known as the Qualities of Nurses (QON) scale, applicable to student nurses. High attrition rates within nursing programs and during early postgraduate years are an international phenomena. Mismatches between idealized perceptions of nursing and the realities of education and clinical experiences have been identified as contributing factors. A survey method was used to elicit responses to scale items from 678 first-year nursing students at a large university. A one-factor 12-item solution explaining 47 percent of variance in the construct was demonstrated. The QON can assist in the initial assessment and ongoing monitoring of changes in students' perceptions of nurses. Using the QON, researchers and educators can identify initial student nurses' perceptions and any changes associated in educational or other events that ultimately could be manipulated to reduce attrition.

  18. Age differences in false memory: The importance of retrieval monitoring processes and their modulation by memory quality.

    PubMed

    Fandakova, Yana; Sander, Myriam C; Grandy, Thomas H; Cabeza, Roberto; Werkle-Bergner, Markus; Shing, Yee Lee

    2018-02-01

    Older adults are more likely than younger adults to falsely recall past episodes that occurred differently or not at all. We examined whether older adults' propensity for false associative memory is related to declines in postretrieval monitoring processes and their modulation with varying memory representations. Younger (N = 20) and older adults (N = 32) studied and relearned unrelated scene-word pairs, followed by a final cued recall that was used to distribute the pairs for an associative recognition test 24 hours later. This procedure allowed individualized formation of rearranged pairs that were made up of elements of pairs that were correctly recalled in the final cued recall ("high-quality" pairs), and of pairs that were not correctly recalled ("low-quality" pairs). Both age groups falsely recognized more low-quality than high-quality rearranged pairs, with a less pronounced reduction in false alarms to high-quality pairs in older adults. In younger adults, cingulo-opercular activity was enhanced for false alarms and for low-quality correct rejections, consistent with its role in postretrieval monitoring. Older adults did not show such modulated recruitment, suggesting deficits in their selective engagement of monitoring processes given variability in the fidelity of memory representations. There were no age differences in hippocampal activity, which was higher for high-quality than low-quality correct rejections in both age groups. These results demonstrate that the engagement of cingulo-opercular monitoring mechanisms varies with memory representation quality and contributes to age-related deficits in false associative memory. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  19. Test-Enhanced Learning in Competence-Based Predoctoral Orthodontics: A Four-Year Study.

    PubMed

    Freda, Nicolas M; Lipp, Mitchell J

    2016-03-01

    Dental educators intend to promote integration of knowledge, skills, and values toward professional competence. Studies report that retrieval, in the form of testing, results in better learning with retention than traditional studying. The aim of this study was to evaluate test-enhanced experiences on demonstrations of competence in diagnosis and management of malocclusion and skeletal problems. The study participants were all third-year dental students (2011 N=88, 2012 N=74, 2013 N=91, 2014 N=85) at New York University College of Dentistry. The 2013 and 2014 groups received the test-enhanced method emphasizing formative assessments with written and dialogic delayed feedback, while the 2011 and 2012 groups received the traditional approach emphasizing lectures and classroom exercises. The students received six two-hour sessions, spaced one week apart. At the final session, a summative assessment consisting of the same four cases was administered. Students constructed a problem list, treatment objectives, and a treatment plan for each case, scored according to the same criteria. Grades were based on the number of cases without critical errors: A=0 critical errors on four cases, A-=0 critical errors on three cases, B+=0 critical errors on two cases, B=0 critical errors on one case, F=critical errors on four cases. Performance grades were categorized as high quality (B+, A-, A) and low quality (F, B). The results showed that the test-enhanced groups demonstrated statistically significant benefits at 95% confidence intervals compared to the traditional groups when comparing low- and high-quality grades. These performance trends support the continued use of the test-enhanced approach.

  20. Multiple dynamics in a single predator-prey system: experimental effects of food quality.

    PubMed Central

    Nelson, W A; McCauley, E; Wrona, F J

    2001-01-01

    Recent work with the freshwater zooplankton Daphnia has suggested that the quality of its algal prey can have a significant effect on its demographic rates and life-history patterns. Predator-prey theory linking food quantity and food quality predicts that a single system should be able to display two distinct patterns of population dynamics. One pattern is predicted to have high herbivore and low algal biomass dynamics (high HBD), whereas the other is predicted to have low herbivore and high algal biomass dynamics (low HBD). Despite these predictions and the stoichiometric evidence that many phytoplankton communities may have poor access to food of quality, there have been few tests of whether a dynamic predator-prey system can display both of these distinct patterns. Here we report, to the authors' knowledge, the first evidence for two dynamical patterns, as predicted by theory, in a single predator-prey system. We show that the high HBD is a result of food quantity effects and that the low HBD is a result of food quality effects, which are maintained by phosphorus limitation in the predator. These results provide an important link between the known effects of nutrient limitation in herbivores and the significance of prey quality in predator-prey population dynamics in natural zooplankton communities. PMID:11410147

  1. Monitoring Score Change Patterns to Support "TOEIC"® Listening and Reading Test Quality. Research Report. ETS RR-17-54

    ERIC Educational Resources Information Center

    Wei, Youhua; Low, Albert

    2017-01-01

    In most large-scale programs of tests that aid in making high-stakes decisions, such as the "TOEIC"® family of products and service, it is not unusual for a significant portion of test takers to retake the test at multiple times.The study reported here used multilevel growth modeling to explore the score change patterns of nearly 20,000…

  2. The interplay between academic performance and quality of life among preclinical students.

    PubMed

    Shareef, Mohammad Abrar; AlAmodi, Abdulhadi A; Al-Khateeb, Abdulrahman A; Abudan, Zainab; Alkhani, Mohammed A; Zebian, Sanderlla I; Qannita, Ahmed S; Tabrizi, Mariam J

    2015-10-31

    The high academic performance of medical students greatly influences their professional competence in long term career. Meanwhile, medical students greatly demand procuring a good quality of life that can help them sustain their medical career. This study examines validity and reliability of the tool among preclinical students and testifies the influence of their scholastic performance along with gender and academic year on their quality of life. A cross sectional study was conducted by distributing World Health Organization Quality of Life, WHOQOL-BREF, survey among medical students of year one to three at Alfaisal University. For validity, item discriminate validity(IDV) and confirmatory factor analysis were measured and for reliability, Cronbach's α test and internal item consistency(IIC) were examined. The association of GPA, gender and academic year with all major domains was drawn using Pearson's correlation, independent samples t-test and one-way ANOVA, respectively. A total of 335 preclinical students have responded to this questionnaire. The construct has demonstrated an adequate validity and good reliability. The high academic performance of students positively correlated with physical (r = 0.23, p < 0.001), psychological health (r = 0.29, p < 0.001), social relations (r = 0.11, p = 0.03) and environment (r = 0.23, p < 0.001). Male student scored higher than female peers in physical and psychological health. This study has identified a direct relationship between the academic performance of preclinical students and their quality of life. The WHOQOL-BREF is a valid and reliable tool among preclinical students and the positive direction of high academic performance with greater QOL suggests that academic achievers procure higher satisfaction and poor achievers need a special attention for the improvement of their quality of life.

  3. Medical information on the internet: a tool for measuring consumer perception of quality aspects.

    PubMed

    Dubowicz, Arthur; Schulz, Peter J

    2015-03-30

    Most of adult Internet users have searched for health information on the Internet. The Internet has become one of the most important sources for health information and treatment advice. In most cases, the information found is not verified with a medical doctor, but judged by the "online-diagnosers" independently. Facing this situation, public health authorities raise concern over the quality of medical information laypersons can find on the Internet. The objective of the study was aimed at developing a measure to evaluate the credibility of websites that offer medical advice and information. The measure was tested in a quasi-experimental study on two sleeping-disorder websites of different quality. There were 45 survey items for rating the credibility of websites that were tested in a quasi-experimental study with a random assignment of 454 participants to either a high- or a low-quality website exposure. Using principal component analysis, the original items were reduced to 13 and sorted into the factors: trustworthiness, textual deficits of the content, interferences (external links on the Web site), and advertisements. The first two factors focus more on the provided content itself, while the other two describe the embedding of the content into the website. The 45 survey items had been designed previously using exploratory observations and literature research. The final scale showed adequate power and reliability for all factors. The loadings of the principal component analysis ranged satisfactorily (.644 to .854). Significant differences at P<.001 were found between the low- and high-quality groups. Advertisements on the website were rated as disturbing in both experimental conditions, meaning that they do not differentiate between good and bad information. The scale reliably distinguished high- and low-quality of medical advice given on websites.

  4. Ethical considerations of providers and clients on HIV testing campaigns in Burkina Faso.

    PubMed

    Desclaux, Alice; Ky-Zerbo, Odette; Somé, Jean-François; Obermeyer, Carla Makhlouf

    2014-10-16

    Campaigns have been conducted in a number of low HIV prevalence African settings, as a strategy to expand HIV testing, and it is important to assess the extent to which individual rights and quality of care are protected during campaigns. In this article we investigate provider and client perceptions of ethical issues, including whether they think that accessibility of counseling and testing sites during campaigns may hinder confidentiality. To examine how campaigns have functioned in Burkina Faso, we undertook a qualitative study based on individual interviews and focus group discussions with 52 people (providers and clients tested during or outside campaigns and individuals never tested). Thematic analysis was performed on discourse about perceptions and experiences of HIV-testing campaigns, quality of care and individual rights. Respondents value testing accessibility and attractiveness during campaigns; clients emphasize convenience, ripple effect, the sense of not being alone, and the anonymity resulting from high attendance. Confronted with numerous clients, providers develop context-specific strategies to ensure consent, counseling, confidentiality and retention in the testing process, and they adapt to workplace arrangements, local resources and social norms. Clients appreciate the quality of care during campaigns. However, new ethical issues arise about confidentiality and accessibility. Confidentiality of HIV-status may be jeopardized due to local social norms that encourage people to share their results with others, when HIV-positive people may not wish to do so. Providers' ethical concerns are consistent with WHO norms known as the '5 Cs,' though articulated differently. Clients and providers value the accessibility of testing for all during campaigns, and consider it an ethical matter. The study yields insights on the way global norms are adapted or negotiated locally. Future global recommendations for HIV testing and counseling campaigns should consider accessibility and propose ways for testing services to respond to new ethical issues related to high demand.

  5. Ethical considerations of providers and clients on HIV testing campaigns in Burkina Faso

    PubMed Central

    2014-01-01

    Background Campaigns have been conducted in a number of low HIV prevalence African settings, as a strategy to expand HIV testing, and it is important to assess the extent to which individual rights and quality of care are protected during campaigns. In this article we investigate provider and client perceptions of ethical issues, including whether they think that accessibility of counseling and testing sites during campaigns may hinder confidentiality. Methods To examine how campaigns have functioned in Burkina Faso, we undertook a qualitative study based on individual interviews and focus group discussions with 52 people (providers and clients tested during or outside campaigns and individuals never tested). Thematic analysis was performed on discourse about perceptions and experiences of HIV-testing campaigns, quality of care and individual rights. Results Respondents value testing accessibility and attractiveness during campaigns; clients emphasize convenience, ripple effect, the sense of not being alone, and the anonymity resulting from high attendance. Confronted with numerous clients, providers develop context-specific strategies to ensure consent, counseling, confidentiality and retention in the testing process, and they adapt to workplace arrangements, local resources and social norms. Clients appreciate the quality of care during campaigns. However, new ethical issues arise about confidentiality and accessibility. Confidentiality of HIV-status may be jeopardized due to local social norms that encourage people to share their results with others, when HIV-positive people may not wish to do so. Providers’ ethical concerns are consistent with WHO norms known as the ‘5 Cs,’ though articulated differently. Clients and providers value the accessibility of testing for all during campaigns, and consider it an ethical matter. The study yields insights on the way global norms are adapted or negotiated locally. Conclusions Future global recommendations for HIV testing and counseling campaigns should consider accessibility and propose ways for testing services to respond to new ethical issues related to high demand. PMID:25322668

  6. Developing software to "track and catch" missed follow-up of abnormal test results in a complex sociotechnical environment.

    PubMed

    Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H

    2013-01-01

    Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.

  7. KRAS mutations testing in colorectal carcinoma patients in Italy: from guidelines to external quality assessment.

    PubMed

    Normanno, Nicola; Pinto, Carmine; Castiglione, Francesca; Bardelli, Alberto; Gambacorta, Marcello; Botti, Gerardo; Nappi, Oscar; Siena, Salvatore; Ciardiello, Fortunato; Taddei, Gianluigi; Marchetti, Antonio

    2011-01-01

    Monoclonal antibodies directed against the epidermal growth factor receptor (EGFR) have been approved for the treatment of patients with metastatic colorectal carcinoma (mCRC) that do not carry KRAS mutations. Therefore, KRAS testing has become mandatory to chose the most appropriate therapy for these patients. In order to guarantee the possibility for mCRC patients to receive an high quality KRAS testing in every Italian region, the Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytopathology -Italian division of the International Academy of Pathology (SIAPEC-IAP) started a program to improve KRAS testing. AIOM and SIAPEC identified a large panel of Italian medical oncologists, pathologists and molecular biologists that outlined guidelines for KRAS testing in mCRC patients. These guidelines include specific information on the target patient population, the biological material for molecular analysis, the extraction of DNA, and the methods for the mutational analysis that are summarized in this paper. Following the publication of the guidelines, the scientific societies started an external quality assessment scheme for KRAS testing. Five CRC specimens with known KRAS mutation status were sent to the 59 centers that participated to the program. The samples were validated by three referral laboratories. The participating laboratories were allowed to use their own preferred method for DNA extraction and mutational analysis and were asked to report the results within 4 weeks. The limit to pass the quality assessment was set at 100% of true responses. In the first round, only two centers did not pass (3%). The two centers were offered to participate to a second round and both centers failed again to pass. The results of this first Italian quality assessment for KRAS testing suggest that KRAS mutational analysis is performed with good quality in the majority of Italian centers. © 2011 Normanno et al.

  8. KRAS Mutations Testing in Colorectal Carcinoma Patients in Italy: From Guidelines to External Quality Assessment

    PubMed Central

    Normanno, Nicola; Pinto, Carmine; Castiglione, Francesca; Bardelli, Alberto; Gambacorta, Marcello; Botti, Gerardo; Nappi, Oscar; Siena, Salvatore; Ciardiello, Fortunato; Taddei, GianLuigi; Marchetti, Antonio

    2011-01-01

    Background Monoclonal antibodies directed against the epidermal growth factor receptor (EGFR) have been approved for the treatment of patients with metastatic colorectal carcinoma (mCRC) that do not carry KRAS mutations. Therefore, KRAS testing has become mandatory to chose the most appropriate therapy for these patients. Methodology/Principal Findings In order to guarantee the possibility for mCRC patients to receive an high quality KRAS testing in every Italian region, the Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytopathology -Italian division of the International Academy of Pathology (SIAPEC-IAP) started a program to improve KRAS testing. AIOM and SIAPEC identified a large panel of Italian medical oncologists, pathologists and molecular biologists that outlined guidelines for KRAS testing in mCRC patients. These guidelines include specific information on the target patient population, the biological material for molecular analysis, the extraction of DNA, and the methods for the mutational analysis that are summarized in this paper. Following the publication of the guidelines, the scientific societies started an external quality assessment scheme for KRAS testing. Five CRC specimens with known KRAS mutation status were sent to the 59 centers that participated to the program. The samples were validated by three referral laboratories. The participating laboratories were allowed to use their own preferred method for DNA extraction and mutational analysis and were asked to report the results within 4 weeks. The limit to pass the quality assessment was set at 100% of true responses. In the first round, only two centers did not pass (3%). The two centers were offered to participate to a second round and both centers failed again to pass. Conclusions The results of this first Italian quality assessment for KRAS testing suggest that KRAS mutational analysis is performed with good quality in the majority of Italian centers. PMID:22216189

  9. Verifying Digital Components of Physical Systems: Experimental Evaluation of Test Quality

    NASA Astrophysics Data System (ADS)

    Laputenko, A. V.; López, J. E.; Yevtushenko, N. V.

    2018-03-01

    This paper continues the study of high quality test derivation for verifying digital components which are used in various physical systems; those are sensors, data transfer components, etc. We have used logic circuits b01-b010 of the package of ITC'99 benchmarks (Second Release) for experimental evaluation which as stated before, describe digital components of physical systems designed for various applications. Test sequences are derived for detecting the most known faults of the reference logic circuit using three different approaches to test derivation. Three widely used fault types such as stuck-at-faults, bridges, and faults which slightly modify the behavior of one gate are considered as possible faults of the reference behavior. The most interesting test sequences are short test sequences that can provide appropriate guarantees after testing, and thus, we experimentally study various approaches to the derivation of the so-called complete test suites which detect all fault types. In the first series of experiments, we compare two approaches for deriving complete test suites. In the first approach, a shortest test sequence is derived for testing each fault. In the second approach, a test sequence is pseudo-randomly generated by the use of an appropriate software for logic synthesis and verification (ABC system in our study) and thus, can be longer. However, after deleting sequences detecting the same set of faults, a test suite returned by the second approach is shorter. The latter underlines the fact that in many cases it is useless to spend `time and efforts' for deriving a shortest distinguishing sequence; it is better to use the test minimization afterwards. The performed experiments also show that the use of only randomly generated test sequences is not very efficient since such sequences do not detect all the faults of any type. After reaching the fault coverage around 70%, saturation is observed, and the fault coverage cannot be increased anymore. For deriving high quality short test suites, the approach that is the combination of randomly generated sequences together with sequences which are aimed to detect faults not detected by random tests, allows to reach the good fault coverage using shortest test sequences.

  10. Bronchiectasis: correlation of high-resolution CT findings with health-related quality of life.

    PubMed

    Eshed, I; Minski, I; Katz, R; Jones, P W; Priel, I E

    2007-02-01

    To evaluate the relationship between the severity of bronchiectatic diseases, as evident on high-resolution computed tomography (HRCT) and the patient's quality of life measured using the St George's Respiratory Questionnaire (SGRQ). Forty-six patients (25 women, 21 men, mean age: 63 years) with bronchiectatic disease as evident on recent HRCT examinations were recruited. Each patient completed the SGRQ and underwent respiratory function tests. HRCT findings were blindly and independently scored by two radiologists, using the modified Bhalla scoring system. The relationships between HRCT scores, SGRQ scores and pulmonary function tests were evaluated. The patients' total CT score did not correlate with the SGRQ scores. However, patients with more advanced disease on HRCT, significantly differed in their SGRQ scores from patients with milder bronchiectatic disease. A significant correlation was found between the CT scores for the middle and distal lung zones and the activity, impacts and total SGRQ scores. No correlation was found between CT scores and respiratory function test indices. However, a significant correlation was found between the SGRQ scores and most of the respiratory function test indices. A correlation between the severity of bronchiectatic disease as expressed in HRCT and the health-related quality of life exists in patients with a more severe bronchiectatic disease but not in patients with mild disease. Such correlation depends on the location of the bronchiectasis in the pulmonary tree.

  11. High Resolution Eddy-Current Wire Testing Based on a Gmr Sensor-Array

    NASA Astrophysics Data System (ADS)

    Kreutzbruck, Marc; Allweins, Kai; Strackbein, Chris; Bernau, Hendrick

    2009-03-01

    Increasing demands in materials quality and cost effectiveness have led to advanced standards in manufacturing technology. Especially when dealing with high quality standards in conjunction with high throughput quantitative NDE techniques are vital to provide reliable and fast quality control systems. In this work we illuminate a modern electromagnetic NDE approach using a small GMR sensor array for testing superconducting wires. Four GMR sensors are positioned around the wire. Each GMR sensor provides a field sensitivity of 200 pT/√Hz and a spatial resolution of about 100 μm. This enables us to detect under surface defects of 100 μm in size in a depth of 200 μm with a signal-to-noise ratio of better than 400. Surface defects could be detected with a SNR of up to 10,000. Besides this remarkably SNR the small extent of GMR sensors results in a spatial resolution which offers new visualisation techniques for defect localisation, defect characterization and tomography-like mapping techniques. We also report on inverse algorithms based on either a Finite Element Method or an analytical approach. These allow for accurate defect localization on the urn scale and an estimation of the defect size.

  12. Predicting High Quality AFQT with Youth Attitude Tracking Study Data

    DTIC Science & Technology

    1991-12-01

    for propensities. The history of the art of mental aptitude and psychological testing is long and convoluted. Names like Sir Francis Galton of England...Qualification Test . The explanatory variables reflect individual demographic, educational and labor market characteristics at the time of YATS interview. The...the fiftieth percentile on the Armed Forces Qualification Test . The explanatory variables reflect individual demographic, educational and labor market

  13. Assessing product image quality for online shopping

    NASA Astrophysics Data System (ADS)

    Goswami, Anjan; Chung, Sung H.; Chittar, Naren; Islam, Atiq

    2012-01-01

    Assessing product-image quality is important in the context of online shopping. A high quality image that conveys more information about a product can boost the buyer's confidence and can get more attention. However, the notion of image quality for product-images is not the same as that in other domains. The perception of quality of product-images depends not only on various photographic quality features but also on various high level features such as clarity of the foreground or goodness of the background etc. In this paper, we define a notion of product-image quality based on various such features. We conduct a crowd-sourced experiment to collect user judgments on thousands of eBay's images. We formulate a multi-class classification problem for modeling image quality by classifying images into good, fair and poor quality based on the guided perceptual notions from the judges. We also conduct experiments with regression using average crowd-sourced human judgments as target. We compute a pseudo-regression score with expected average of predicted classes and also compute a score from the regression technique. We design many experiments with various sampling and voting schemes with crowd-sourced data and construct various experimental image quality models. Most of our models have reasonable accuracies (greater or equal to 70%) on test data set. We observe that our computed image quality score has a high (0.66) rank correlation with average votes from the crowd sourced human judgments.

  14. Turnaround Arts Initiative: Summary of Key Findings

    ERIC Educational Resources Information Center

    Stoelinga, Sara Ray; Silk, Yael; Reddy, Prateek; Rahman, Nadiv

    2015-01-01

    Turnaround Arts is a public-private partnership that aims to test the hypothesis that strategically implementing high-quality and integrated arts education programming in high-poverty, chronically underperforming schools adds significant value to school-wide reform. In 2014, the Turnaround Arts initiative completed an evaluation report covering…

  15. Cross-species conservation of endocrine pathways provides a basis for reevaluation of EDSP tiered testing paradigm

    EPA Science Inventory

    Many structural and functional aspects of the vertebrate hypothalamic-pituitary-gonadal (HPG) axis are known to be highly conserved, but the relative significance of this from a regulatory toxicology perspective has received comparatively little attention. High-quality data gene...

  16. What makes a great radiology review course lecture: the Ottawa radiology resident review course experience.

    PubMed

    Cao, Lilly; McInnes, Matthew D F; Ryan, John O

    2014-02-01

    Little objective evidence exists regarding what makes a good lecture. Our purpose was to determine qualities of radiology review course lectures that are associated with positive audience evaluation. 57 presentations from the Ottawa Resident Review Course (2012) were analyzed by a PGY4 radiology resident blinded to the result of audience evaluation. Objective data extracted were: slides per minute, lines of text per text slide, words per text slide, cases per minute, images per minute, images per case, number of audience laughs, number of questions posed to the audience, number of summaries, inclusion of learning objectives, ending on time, use of pre/post-test and use of special effects. Mean audience evaluation scores for each talk from daily audience evaluations (up to 60 per talk) were standardized out of 100. Correlation coefficient was calculated between continuous variables and audience evaluation scores. Student T test was performed on categorical variables and audience evaluation scores. Strongest positive association with audience evaluation scores was for image quality (r = 0.57) and number of times the audience laughed (r = 0.3). Strongest negative association was between images per case and audience scores (r = -0.25). Talks with special effects were rated better (mean score 94.3 vs. 87.1, p < 0.001). Talks with the highest image quality were rated better (mean score 94.1 vs. 87.5, p < 0.001). Talks which contained a pre/post-test were rated better (mean score 92 vs. 87.8, p = 0.004). Many factors go into making a great review course lecture. At the University of Ottawa Resident Review Course, high quality images, use of special effects, use of pre/post-test and humor were most strongly associated with high audience evaluation scores. High image volume per case may be negatively associated with audience evaluation scores.

  17. Solar Technology Acceleration Center (SolarTAC): Solar Resource & Meteorological Assessment Project (SOLRAMP)

    DOE Data Explorer

    Andreas, Afshin; Wilcox, Steve

    2016-03-14

    Located in Colorado, near Denver International Airport, SolarTAC is a private, member-based, 74-acre outdoor facility where the solar industry tests, validates, and demonstrates advanced solar technologies. SolarTAC was launched in 2008 by a public-private consortium, including Midwest Research Institute (MRI). As a supporting member of SolarTAC, the U.S. Department of Energy National Renewable Energy Laboratory (NMREL) has established a high quality solar and meteorological measurement station at this location. This Solar Resource and Meteorological Assessment Project (SOLRMAP) provides high quality measurements to support deployment of power projects in the United States. The no-funds-exchanged collaboration brings NREL solar resource assessment expertise together with industry needs for measurements. The end result is high quality data sets to support the financing, design, and monitoring of large scale solar powered projects for industry in addition to research-quality data for NREL model development. NREL provides consultation for instrumentation and station deployment, along with instrument calibrations, data acquisition, quality assessment, data distribution, and summary reports. Industry participants provide equipment, infrastructure, and station maintenance.

  18. Applicability of ambient toxicity testing to national or regional water-quality assessment

    USGS Publications Warehouse

    Elder, John F.

    1990-01-01

    Comprehensive assessment of the quality of natural waters requires a multifaceted approach. Descriptions of existing conditions may be achieved by various kinds of chemical and hydrologic analyses, whereas information about the effects of such conditions on living organisms depends on biological monitoring. Toxicity testing is one type of biological monitoring that can be used to identify possible effects of toxic contaminants. Based on experimentation designed to monitor responses of organisms to environmental stresses, toxicity testing may have diverse purposes in water-quality assessments. These purposes may include identification of areas that warrant further study because of poor water quality or unusual ecological features, verification of other types of monitoring, or assessment of contaminant effects on aquatic communities. Toxicity-test results are most effective when used as a complement to chemical analyses, hydrologic measurements, and other biological monitoring. However, all toxicity-testing procedures have certain limitations that must be considered in developing the methodology and applications of toxicity testing in any large-scale water-quality-assessment program. A wide variety of toxicity-test methods have been developed to fulfill the needs of diverse applications. The methods differ primarily in the selections made relative to four characteristics: (1) test species, (2) endpoint (acute or chronic), (3) test-enclosure type, and (4) test substance (toxicant) that functions as the environmental stress. Toxicity-test approaches vary in their capacity to meet the needs of large-scale assessments of existing water quality. Ambient testing, whereby the test organism is exposed to naturally occurring substances that contain toxicant mixtures in an organic or inorganic matrix, is more likely to meet these needs than are procedures that call for exposure of the test organisms to known concentrations of a single toxicant. However, meaningful interpretation of ambient test results depends on the existence of accompanying chemical analysis of the ambient media. The ambient test substance may be water or sediments. Sediment tests have had limited application, but they are useful because most toxicants tend to accumulate in sediments and many test species either inhabit the sediments or are in frequent contact with them. Biochemical testing methods, which have been developing rapidly in recent years, are likely to be among the most useful procedures for large-scale water-quality assessments. They are relatively rapid and simple, and more. importantly, they focus on biochemical changes that are the initial responses of virtually all organisms to environmental stimuli. Most species are sensitive to relatively few toxicants, and their sensitivities vary as conditions change. Therefore, each test method has particular uses and limitations, and no single test has universal applicability. One of the most informative approaches to toxicity testing is to combine biochemical tests with other test methods in a 'battery of tests' that is diversified enough to characterize different types of toxicants and different trophic levels. However, such an approach can be costly, and if not carefully designed, it may not yield enough additional information to warrant the additional cost. The application of toxicity tests to large-scale water-quality assessments is hampered by a number of difficulties. Toxicity tests often are not sensitive enough to enable detection of most contaminant problems in the natural environment. Furthermore, because sensitivities among different species and test conditions can be highly variable, conclusions about the toxicant problems of an ecosystem are strongly dependent on the test procedure used. In addition, the experimental systems used in toxicity tests cannot replicate the complexity or variability of natural conditions, and positive test results cannot identify the source or nature of

  19. Nondestructive Evaluation of Adhesive Bond Quality: State of the Art Review

    DTIC Science & Technology

    1989-06-01

    conducted using a and Harnik (6) developed a quantitative medium-focused, 1/4-inch diameter, 10-MHz method of testing adhesive bonded joints transducer...Couchman." Spectral Analysis Tech- E. Harnik . "The Testing of Adhesive- nique of Ultrasonic NDT of Advanced Bonded Joints by a Very High Resolu

  20. 40 CFR 51.363 - Quality assurance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performing all tests and other required functions. Performance audits shall be of two types: overt and covert... least twice per year for each lane or test bay and shall include: (i) A check for the observance of... the use of aids such as binoculars or video cameras, at least once per year per inspector in high...

  1. 40 CFR 51.363 - Quality assurance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... performing all tests and other required functions. Performance audits shall be of two types: overt and covert... least twice per year for each lane or test bay and shall include: (i) A check for the observance of... the use of aids such as binoculars or video cameras, at least once per year per inspector in high...

  2. Tests on a pilot plant for reheating desulfurized flue gases with the help of heat pipes

    NASA Astrophysics Data System (ADS)

    Schug, W.

    1982-02-01

    Desulfurized flue gases were reheated with a heat pipe heat exchanger. Finned heat pipes, with a coating or made of high quality steel were subjected to different operating conditions for 1000 hr. The coating proved to be unsuitable for heat transfer because it swells and detaches itself from the background material. The high quality steels showed pitting and surface corrosion. The possibilities of cleaning were also studied to prevent deposits forming on the heat pipes, but no solution was found.

  3. Evaluation of Microbial Contamination and Chemical Qualities of Cream-filled Pastries in Confectioneries of Chaharmahal Va Bakhtiari Province (Southwestern Iran).

    PubMed

    Sharifzadeh, Ali; Hajsharifi-Shahreza, Mohammad; Ghasemi-Dehkordi, Payam

    2016-12-01

    High consumption of bakery products such as cream-filled pastries may cause serious health risks and food poisoning to humans. Therefore, investigation of the microbial and chemical qualities of bakery products containing cream is necessary. The purpose of the present study was to investigate the chemical qualities and microbial contaminations of cream-filled pastries collected from confectioneries located in six cities in Chaharmahal Va Bakhtiari province (Southwestern Iran). Microbial tests and chemical characteristics (fat and acidity level) were done on 228 cream-filled pastries samples that were collected randomly from various confectioneries. After microbial tests, it was found that 33.33% of all samples were contaminated by microbial agents. The microbial tests showed that Shahrekord (10.09%) and Broujen (9.21%) cities had high levels of contamination and in Koohrang (1.31%) it was low compared with the other four cities. High contamination of coliforms (61.84%), staphylococci (48.68%), and yeast (27.63%) were observed in almost all samples. The chemical analysis showed maximum amounts of fat content and titratable acidity in cream-filled pastry samples obtained from Lordegan and Shahrekord cities, respectively. The findings of the present work demonstrated that the microbial contamination and chemical quality of cream-filled pastries produced in confectionaries of Chaharmahal Va Bakhtiari province were not in acceptable ranges. These problems may be related to fecal contamination of cream samples or lack of hygiene by handlers and it is necessary to observe the standards of hygiene and to develop safe food handling techniques and aseptic pastry manufacturing systems in some confectioneries of Chaharmahal Va Bakhtiari province.

  4. Quality of life, psychological burden, needs, and satisfaction during specialized inpatient palliative care in family caregivers of advanced cancer patients.

    PubMed

    Ullrich, Anneke; Ascherfeld, Lilian; Marx, Gabriella; Bokemeyer, Carsten; Bergelt, Corinna; Oechsle, Karin

    2017-05-10

    This pilot study aimed to investigate quality of life, psychological burden, unmet needs, and care satisfaction in family caregivers of advanced cancer patients (FCs) during specialized inpatient palliative care (SIPC) and to test feasibility and acceptance of the questionnaire survey. During a period of 12 weeks, FCs were recruited consecutively within 72 h after the patient's admission. They completed validated scales on several outcomes: quality of life (SF-8), distress (DT), anxiety (GAD-7), depression (PHQ-9), supportive needs (FIN), palliative care outcome (POS), and satisfaction with care (FAMCARE-2). We used non-parametric tests, t-tests and correlation analyses to address our research questions. FCs showed high study commitment: 74 FCs were asked to participate whereof 54 (73%) agreed and 51 (69%) returned the questionnaire. Except for "bodily pain", FCs' quality of life (SF-8) was impaired in all subscales. Most FCs (96%) reported clinically significant own distress (DT), with sadness, sorrows and exhaustion being the most distressing problems (80-83%). Moderate to severe anxiety (GAD-7) and depression (PHQ-9) were prevalent in 43% and 41% of FCs, respectively. FCs scored a mean number of 16.3 of 20 needs (FIN) as very or extremely important (SD 3.3), 20% of needs were unmet in >50% of FCs. The mean POS score assessed by FCs was 16.6 (SD 5.0) and satisfaction (FAMCARE-2) was high (73.4; SD 8.3). This pilot study demonstrated feasibility of the questionnaire survey and showed relevant psychosocial burden and unmet needs in FCs during SIPC. However, FCs' satisfaction with SIPC seemed to be high. A current multicenter study evaluates these findings longitudinally in a large cohort of FCs.

  5. Testing of optical components to assure performance in a high-average-power environment

    NASA Astrophysics Data System (ADS)

    Chow, Robert; Taylor, John R.; Eickelberg, William K.; Primdahl, Keith A.

    1997-11-01

    Evaluation and testing of the optical components used in the atomic vapor laser isotope separation plant is critical for qualification of suppliers, developments of new optical multilayer designs and manufacturing processes, and assurance of performance in the production cycle. The range of specifications requires development of specialized test equipment and methods which are not routine or readily available in industry. Specifications are given on material characteristics such as index homogeneity, subsurface damage left after polishing, microscopic surface defects and contamination, coating absorption, and high average power laser damage. The approach to testing these performance characteristics and assuring the quality throughout the production cycle is described.

  6. Availability and Quality of Family Planning Services in the Democratic Republic of the Congo: High Potential for Improvement.

    PubMed

    Mpunga, Dieudonné; Lumbayi, J P; Dikamba, Nelly; Mwembo, Albert; Ali Mapatano, Mala; Wembodinga, Gilbert

    2017-06-27

    To determine the availability and quality of family planning services within health facilities throughout the Democratic Republic of the Congo (DRC). Data were collected for the cross-sectional study from April 2014 to June 2014 by the Ministry of Public Health. A total of 1,568 health facilities that reported data to the National Health Information System were selected by multistage random sampling in the 11 provinces of the DRC existing at that time. Data were collected through interviews, document review, and direct observation. Two dependent variables were measured: availability of family planning services (consisting of a room for services, staff assigned to family planning, and evidence of client use of family planning) and quality of family planning services (assessed as "high" if the facility had at least 1 trained staff member, family planning service delivery guidelines, at least 3 types of methods, and a sphygmomanometer, or "low" if the facility did not meet any of these 4 criteria). Pearson's chi-square test and odds ratios (ORs) were used to test for significant associations, using the alpha significance level of .05. We successfully surveyed 1,555 facilities (99.2%) of those included in the sample. One in every 3 facilities (33%) offered family planning services as assessed by the index of availability, of which 20% met all 4 criteria for providing high-quality services. Availability was greatest at the highest level of the health system (hospitals) and decreased incrementally with each health system level, with disparities between provinces and urban and rural areas. Facilities in urban areas were more likely than in rural areas to meet the standard for high-quality services ( P <.001). Public facilities were less likely than private facilities to have high-quality services ( P =.02). Among all 1,555 facilities surveyed, 14% had at least 3 types of methods available at the time of the survey; the most widely available methods were male condoms, combined oral contraceptive pills, and progestin-only injectable contraceptives. Availability and quality of family planning services in health facilities in the DRC remain low, with inequitable distribution of services throughout the country. To improve access to and use of family planning, efforts should focus on improving availability and quality at lower health system levels and in rural areas where the majority of the population lives. © Mpunga et al.

  7. Changes in the relationship between nursing home financial performance and quality of care under public reporting.

    PubMed

    Park, Jeongyoung; Werner, Rachel M

    2011-07-01

    The relationship between financial performance and quality of care in nursing homes is not well defined and prior work has been mixed. The recent focus on improving the quality of nursing homes through market-based incentives such as public reporting may have changed this relationship, as public reporting provides nursing homes with increased incentives to engage in quality-based competition. If quality improvement activities require substantial production costs, nursing home profitability may become a more important predictor of quality under public reporting. This study explores the relationship between financial performance and quality of care and test whether this relationship changes under public reporting. Using a 10-year (fiscal years 1997-2006) panel data set of 9444 skilled nursing facilities in the US, this study employs a facility fixed-effects with and without instrumental variables approach to test the effect of finances on quality improvement and correct for potential endogeneity. The results show that better financial performance, as reflected by the 1-year lagged total profit margin, is modestly associated with higher quality but only after public reporting is initiated. These findings have important policy implications as federal and state governments use market-based incentives to increase demand for high-quality care and induce providers to compete based on quality. Copyright © 2010 John Wiley & Sons, Ltd.

  8. Performance Assessment of Internal Quality Control (IQC) Products in Blood Transfusion Compatibility Testing in China

    PubMed Central

    Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan

    2015-01-01

    Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582

  9. Laminated thermoplastic composite material from recycled high density polyethylene

    NASA Technical Reports Server (NTRS)

    Liu, Ping; Waskom, Tommy L.

    1994-01-01

    The design of a materials-science, educational experiment is presented. The student should understand the fundamentals of polymer processing and mechanical property testing of materials. The ability to use American Society for Testing and Materials (ASTM) standards is also necessary for designing material test specimens and testing procedures. The objectives of the experiment are (1) to understand the concept of laminated composite materials, processing, testing, and quality assurance of thermoplastic composites and (2) to observe an application example of recycled plastics.

  10. Quality of HIV Testing Data Before and After the Implementation of a National Data Quality Assessment and Feedback System.

    PubMed

    Beltrami, John; Wang, Guoshen; Usman, Hussain R; Lin, Lillian S

    In 2010, the Centers for Disease Control and Prevention (CDC) implemented a national data quality assessment and feedback system for CDC-funded HIV testing program data. Our objective was to analyze data quality before and after feedback. Coinciding with required quarterly data submissions to CDC, each health department received data quality feedback reports and a call with CDC to discuss the reports. Data from 2008 to 2011 were analyzed. Fifty-nine state and local health departments that were funded for comprehensive HIV prevention services. Data collected by a service provider in conjunction with a client receiving HIV testing. National data quality assessment and feedback system. Before and after intervention implementation, quality was assessed through the number of new test records reported and the percentage of data values that were neither missing nor invalid. Generalized estimating equations were used to assess the effect of feedback in improving the completeness of variables. Data were included from 44 health departments. The average number of new records per submission period increased from 197 907 before feedback implementation to 497 753 afterward. Completeness was high before and after feedback for race/ethnicity (99.3% vs 99.3%), current test results (99.1% vs 99.7%), prior testing and results (97.4% vs 97.7%), and receipt of results (91.4% vs 91.2%). Completeness improved for HIV risk (83.6% vs 89.5%), linkage to HIV care (56.0% vs 64.0%), referral to HIV partner services (58.9% vs 62.8%), and referral to HIV prevention services (55.3% vs 63.9%). Calls as part of feedback were associated with improved completeness for HIV risk (adjusted odds ratio [AOR] = 2.28; 95% confidence interval [CI], 1.75-2.96), linkage to HIV care (AOR = 1.60; 95% CI, 1.31-1.96), referral to HIV partner services (AOR = 1.73; 95% CI, 1.43-2.09), and referral to HIV prevention services (AOR = 1.74; 95% CI, 1.43-2.10). Feedback contributed to increased data quality. CDC and health departments should continue monitoring the data and implement measures to improve variables of low completeness.

  11. Advanced Computational Methods for High-accuracy Refinement of Protein Low-quality Models

    NASA Astrophysics Data System (ADS)

    Zang, Tianwu

    Predicting the 3-dimentional structure of protein has been a major interest in the modern computational biology. While lots of successful methods can generate models with 3˜5A root-mean-square deviation (RMSD) from the solution, the progress of refining these models is quite slow. It is therefore urgently needed to develop effective methods to bring low-quality models to higher-accuracy ranges (e.g., less than 2 A RMSD). In this thesis, I present several novel computational methods to address the high-accuracy refinement problem. First, an enhanced sampling method, named parallel continuous simulated tempering (PCST), is developed to accelerate the molecular dynamics (MD) simulation. Second, two energy biasing methods, Structure-Based Model (SBM) and Ensemble-Based Model (EBM), are introduced to perform targeted sampling around important conformations. Third, a three-step method is developed to blindly select high-quality models along the MD simulation. These methods work together to make significant refinement of low-quality models without any knowledge of the solution. The effectiveness of these methods is examined in different applications. Using the PCST-SBM method, models with higher global distance test scores (GDT_TS) are generated and selected in the MD simulation of 18 targets from the refinement category of the 10th Critical Assessment of Structure Prediction (CASP10). In addition, in the refinement test of two CASP10 targets using the PCST-EBM method, it is indicated that EBM may bring the initial model to even higher-quality levels. Furthermore, a multi-round refinement protocol of PCST-SBM improves the model quality of a protein to the level that is sufficient high for the molecular replacement in X-ray crystallography. Our results justify the crucial position of enhanced sampling in the protein structure prediction and demonstrate that a considerable improvement of low-accuracy structures is still achievable with current force fields.

  12. Rapid-Testing Technology and Systems Improvement for the Elimination of Congenital Syphilis in Haiti: Overcoming the “Technology to Systems Gap”

    PubMed Central

    Benoit, Daphne; Zhou, Xi K.; Pape, Jean W.; Peeling, Rosanna W.; Fitzgerald, Daniel W.; Mate, Kedar S.

    2013-01-01

    Background. Despite the availability of rapid diagnostic tests and inexpensive treatment for pregnant women, maternal-child syphilis transmission remains a leading cause of perinatal morbidity and mortality in developing countries. In Haiti, more than 3000 babies are born with congenital syphilis annually. Methods and Findings. From 2007 to 2011, we used a sequential time series, multi-intervention study design in fourteen clinics throughout Haiti to improve syphilis testing and treatment in pregnancy. The two primary interventions were the introduction of a rapid point-of-care syphilis test and systems strengthening based on quality improvement (QI) methods. Syphilis testing increased from 91.5% prediagnostic test to 95.9% after (P < 0.001) and further increased to 96.8% (P < 0.001) after the QI intervention. Despite high rates of testing across all time periods, syphilis treatment lagged behind and only increased from 70.3% to 74.7% after the introduction of rapid tests (P = 0.27), but it improved significantly from 70.2% to 84.3% (P < 0.001) after the systems strengthening QI intervention. Conclusion. Both point-of-care diagnostic testing and health systems-based quality improvement interventions can improve the delivery of specific evidence-based healthcare interventions to prevent congenital syphilis at scale in Haiti. Improved treatment rates for syphilis were seen only after the use of systems-based quality improvement approaches. PMID:26316955

  13. Rapid-Testing Technology and Systems Improvement for the Elimination of Congenital Syphilis in Haiti: Overcoming the "Technology to Systems Gap".

    PubMed

    Severe, Linda; Benoit, Daphne; Zhou, Xi K; Pape, Jean W; Peeling, Rosanna W; Fitzgerald, Daniel W; Mate, Kedar S

    2013-01-01

    Background. Despite the availability of rapid diagnostic tests and inexpensive treatment for pregnant women, maternal-child syphilis transmission remains a leading cause of perinatal morbidity and mortality in developing countries. In Haiti, more than 3000 babies are born with congenital syphilis annually. Methods and Findings. From 2007 to 2011, we used a sequential time series, multi-intervention study design in fourteen clinics throughout Haiti to improve syphilis testing and treatment in pregnancy. The two primary interventions were the introduction of a rapid point-of-care syphilis test and systems strengthening based on quality improvement (QI) methods. Syphilis testing increased from 91.5% prediagnostic test to 95.9% after (P < 0.001) and further increased to 96.8% (P < 0.001) after the QI intervention. Despite high rates of testing across all time periods, syphilis treatment lagged behind and only increased from 70.3% to 74.7% after the introduction of rapid tests (P = 0.27), but it improved significantly from 70.2% to 84.3% (P < 0.001) after the systems strengthening QI intervention. Conclusion. Both point-of-care diagnostic testing and health systems-based quality improvement interventions can improve the delivery of specific evidence-based healthcare interventions to prevent congenital syphilis at scale in Haiti. Improved treatment rates for syphilis were seen only after the use of systems-based quality improvement approaches.

  14. Impact of normalization methods on high-throughput screening data with high hit rates and drug testing with dose-response data.

    PubMed

    Mpindi, John-Patrick; Swapnil, Potdar; Dmitrii, Bychkov; Jani, Saarela; Saeed, Khalid; Wennerberg, Krister; Aittokallio, Tero; Östling, Päivi; Kallioniemi, Olli

    2015-12-01

    Most data analysis tools for high-throughput screening (HTS) seek to uncover interesting hits for further analysis. They typically assume a low hit rate per plate. Hit rates can be dramatically higher in secondary screening, RNAi screening and in drug sensitivity testing using biologically active drugs. In particular, drug sensitivity testing on primary cells is often based on dose-response experiments, which pose a more stringent requirement for data quality and for intra- and inter-plate variation. Here, we compared common plate normalization and noise-reduction methods, including the B-score and the Loess a local polynomial fit method under high hit-rate scenarios of drug sensitivity testing. We generated simulated 384-well plate HTS datasets, each with 71 plates having a range of 20 (5%) to 160 (42%) hits per plate, with controls placed either at the edge of the plates or in a scattered configuration. We identified 20% (77/384) as the critical hit-rate after which the normalizations started to perform poorly. Results from real drug testing experiments supported this estimation. In particular, the B-score resulted in incorrect normalization of high hit-rate plates, leading to poor data quality, which could be attributed to its dependency on the median polish algorithm. We conclude that a combination of a scattered layout of controls per plate and normalization using a polynomial least squares fit method, such as Loess helps to reduce column, row and edge effects in HTS experiments with high hit-rates and is optimal for generating accurate dose-response curves. john.mpindi@helsinki.fi. Supplementary information: R code and Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press.

  15. The link between leadership and safety outcomes in hospitals.

    PubMed

    Squires, Mae; Tourangeau, Ann; Spence Laschinger, Heather K; Doran, Diane

    2010-11-01

    To test and refine a model examining relationships among leadership, interactional justice, quality of the nursing work environment, safety climate and patient and nurse safety outcomes. The quality of nursing work environments may pose serious threats to patient and nurse safety. Justice is an important element in work environments that support safety initiatives yet little research has been done that looks at how leader interactional justice influences safety outcomes. A cross-sectional survey was conducted with 600 acute care registered nurses (RNs) to test and refine a model linking interactional justice, the quality of nurse leader-nurse relationships, work environment and safety climate with patient and nurse outcomes. In general the hypothesized model was supported. Resonant leadership and interactional justice influenced the quality of the leader-nurse relationship which in turn affected the quality of the work environment and safety climate. This ultimately was associated with decreased reported medication errors, intentions to leave and emotional exhaustion. Quality relationships based on fairness and empathy play a pivotal role in creating positive safety climates and work environments. To advocate for safe work environments, managers must strive to develop high-quality relationships through just leadership practices. © 2010 The Authors. Journal compilation © 2010 Blackwell Publishing Ltd.

  16. Quality of life of patients undergoing surgery by videolaparoscopy for GERD treatment.

    PubMed

    Andrade, Francisco José Cavalcante; de Almeida, Eliete Rodrigues; dos Santos, Maria Teresa Botti Rodrigues; Soares-Filho, Eurípedes; Lopes, João Batista; Veras e Silva, Roberto Cavalcante

    2012-01-01

    Gastroesophageal reflux disease is a chronic disease of high prevalence in Western countries, with negative effects on quality of life. Surgery is indicated for patients with intolerance to continuous medication, prolonged treatment or control, or in complicated forms of the disease. To evaluate the quality of life of patients undergoing surgery by videolaparoscopy for gastroesophageal reflux disease treatment. Sample comprised 43 patients of both genders (mean age = 51.4 years). For quality of life evaluation was made using the questionnaire Gastroesophageal Reflux Disease Health Related Quality of Life, translated and validated into Portuguese. Data were analyzed by Epi Info version 3.5.1, using Duncan test and Pearson's correlation coefficient, with 5% for null hypothesis (p ≤ 0.05). Over 50% of participants showed good quality of life (scores <5 of the questionnaire), more than 90% indicated satisfaction with their health. A significant positive correlation between most variables related to heartburn and the time after surgery was observed (p ≤ 0.05). Patients presented good quality of life and high level of satisfaction with their postoperative condition.

  17. Testing Students with Special Educational Needs in Large-Scale Assessments – Psychometric Properties of Test Scores and Associations with Test Taking Behavior

    PubMed Central

    Pohl, Steffi; Südkamp, Anna; Hardt, Katinka; Carstensen, Claus H.; Weinert, Sabine

    2016-01-01

    Assessing competencies of students with special educational needs in learning (SEN-L) poses a challenge for large-scale assessments (LSAs). For students with SEN-L, the available competence tests may fail to yield test scores of high psychometric quality, which are—at the same time—measurement invariant to test scores of general education students. We investigated whether we can identify a subgroup of students with SEN-L, for which measurement invariant competence measures of adequate psychometric quality may be obtained with tests available in LSAs. We furthermore investigated whether differences in test-taking behavior may explain dissatisfying psychometric properties and measurement non-invariance of test scores within LSAs. We relied on person fit indices and mixture distribution models to identify students with SEN-L for whom test scores with satisfactory psychometric properties and measurement invariance may be obtained. We also captured differences in test-taking behavior related to guessing and missing responses. As a result we identified a subgroup of students with SEN-L for whom competence scores of adequate psychometric quality that are measurement invariant to those of general education students were obtained. Concerning test taking behavior, there was a small number of students who unsystematically picked response options. Removing these students from the sample slightly improved item fit. Furthermore, two different patterns of missing responses were identified that explain to some extent problems in the assessments of students with SEN-L. PMID:26941665

  18. The failure of routine rapid HIV testing: a case study of improving low sensitivity in the field.

    PubMed

    Wolpaw, Benjamin J; Mathews, Catherine; Chopra, Mickey; Hardie, Diana; de Azevedo, Virginia; Jennings, Karen; Lurie, Mark N

    2010-03-22

    The rapid HIV antibody test is the diagnostic tool of choice in low and middle-income countries. Previous evidence suggests that rapid HIV diagnostic tests may underperform in the field, failing to detect a substantial number of infections. A research study inadvertently discovered that a clinic rapid HIV testing process was failing to detect cases of established (high antibody titer) infection, exhibiting an estimated 68.7% sensitivity (95% CI [41.3%-89.0%]) over the course of the first three weeks of observation. The setting is a public service clinic that provides STI diagnosis and treatment in an impoverished, peri-urban community outside of Cape Town, South Africa. The researchers and local health administrators collaborated to investigate the cause of the poor test performance and make necessary corrections. The clinic changed the brand of rapid test being used and later introduced quality improvement measures. Observations were made of the clinic staff as they administered rapid HIV tests to real patients. Estimated testing sensitivity was calculated as the number of rapid HIV test positive individuals detected by the clinic divided by this number plus the number of PCR positive, highly reactive 3rd generation ELISA patients identified among those who were rapid test negative at the clinic. In the period of five months after the clinic made the switch of rapid HIV tests, estimated sensitivity improved to 93.5% (95% CI [86.5%-97.6%]), during which time observations of counselors administering tests at the clinic found poor adherence to the recommended testing protocol. Quality improvement measures were implemented and estimated sensitivity rose to 95.1% (95% CI [83.5%-99.4%]) during the final two months of full observation. Poor testing procedure in the field can lead to exceedingly low levels of rapid HIV test sensitivity, making it imperative that stringent quality control measures are implemented where they do not already exist. Certain brands of rapid-testing kits may perform better than others when faced with sub-optimal use.

  19. Ultrasonic test of resistance spot welds based on wavelet package analysis.

    PubMed

    Liu, Jing; Xu, Guocheng; Gu, Xiaopeng; Zhou, Guanghao

    2015-02-01

    In this paper, ultrasonic test of spot welds for stainless steel sheets has been studied. It is indicated that traditional ultrasonic signal analysis in either time domain or frequency domain remains inadequate to evaluate the nugget diameter of spot welds. However, the method based on wavelet package analysis in time-frequency domain can easily distinguish the nugget from the corona bond by extracting high-frequency signals in different positions of spot welds, thereby quantitatively evaluating the nugget diameter. The results of ultrasonic test fit the actual measured value well. Mean value of normal distribution of error statistics is 0.00187, and the standard deviation is 0.1392. Furthermore, the quality of spot welds was evaluated, and it is showed ultrasonic nondestructive test based on wavelet packet analysis can be used to evaluate the quality of spot welds, and it is more reliable than single tensile destructive test. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Design of video processing and testing system based on DSP and FPGA

    NASA Astrophysics Data System (ADS)

    Xu, Hong; Lv, Jun; Chen, Xi'ai; Gong, Xuexia; Yang, Chen'na

    2007-12-01

    Based on high speed Digital Signal Processor (DSP) and Field Programmable Gate Array (FPGA), a video capture, processing and display system is presented, which is of miniaturization and low power. In this system, a triple buffering scheme was used for the capture and display, so that the application can always get a new buffer without waiting; The Digital Signal Processor has an image process ability and it can be used to test the boundary of workpiece's image. A video graduation technology is used to aim at the position which is about to be tested, also, it can enhance the system's flexibility. The character superposition technology realized by DSP is used to display the test result on the screen in character format. This system can process image information in real time, ensure test precision, and help to enhance product quality and quality management.

  1. Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring.

    PubMed

    Hojaiji, Hannaneh; Kalantarian, Haik; Bui, Alex A T; King, Christine E; Sarrafzadeh, Majid

    2017-03-01

    This paper introduces the design, calibration, and validation of a low-cost portable sensor for the real-time measurement of dust particles within the environment. The proposed design consists of low hardware cost and calibration based on temperature and humidity sensing to achieve accurate processing of airborne dust density. Using commercial particulate matter sensors, a highly accurate air quality monitoring sensor was designed and calibrated using real world variations in humidity and temperature for indoor and outdoor applications. Furthermore, to provide a low-cost secure solution for real-time data transfer and monitoring, an onboard Bluetooth module with AES data encryption protocol was implemented. The wireless sensor was tested against a Dylos DC1100 Pro Air Quality Monitor, as well as an Alphasense OPC-N2 optical air quality monitoring sensor for accuracy. The sensor was also tested for reliability by comparing the sensor to an exact copy of itself under indoor and outdoor conditions. It was found that accurate measurements under real-world humid and temperature varying and dynamically changing conditions were achievable using the proposed sensor when compared to the commercially available sensors. In addition to accurate and reliable sensing, this sensor was designed to be wearable and perform real-time data collection and transmission, making it easy to collect and analyze data for air quality monitoring and real-time feedback in remote health monitoring applications. Thus, the proposed device achieves high quality measurements at lower-cost solutions than commercially available wireless sensors for air quality.

  2. Premenstrual Syndrome in Turkish college students and its effects on life quality.

    PubMed

    Pinar, Gul; Colak, Meric; Oksuz, Ergun

    2011-01-01

    The purpose of this research is to analyze the frequency of Premenstrual Syndrome (PMS) in college students, the factors affecting Premenstrual Syndrome and the effect of Premenstrual Syndrome on life quality. The research was performed on 316 students who study at Medical Sciences Faculty of Başkent University and accepted to take part in the research. The data of the research was compiled by using "Questionnaire Form", "PMS Rating Scale" and "Life Quality Scale" developed by the researchers. In the analysis of the data; Percentage distribution, Chi-square test, One Way Anova test, Logistic regression, Multi nominal regression analysis were used. PMS was detected in 72.1% of the students. The most frequent symptoms are mainly low back pain, stress-discomfort, nervous-anger, distention and breast tenderness. PMS was found significantly high in those students who have menstrual irregularity, who have dysmenorrhea, who consume 2 cups of coffee or above per day and who smoke and drink alcohol (p<0.05). When the relation of PMS with life quality was evaluated, it was determined that the life quality decreases as PMS score average increases (p<0.05). PMS rate is high in college students and this adversely affects the life quality. It was revealed that the preventive, instructive and consultancy roles of the medical staff became more of an issue in reducing the effect of the factors causing and/or aggravating these symptoms in order to decrease PMS incidence and to improve the life quality of the students. Copyright © 2010. Published by Elsevier B.V.

  3. Radiation dose and image quality for paediatric interventional cardiology

    NASA Astrophysics Data System (ADS)

    Vano, E.; Ubeda, C.; Leyton, F.; Miranda, P.

    2008-08-01

    Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 µGy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 µGy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.

  4. Developing Software to “Track and Catch” Missed Follow-up of Abnormal Test Results in a Complex Sociotechnical Environment

    PubMed Central

    Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.

    2013-01-01

    Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789

  5. Monitoring the quality of welding based on welding current and ste analysis

    NASA Astrophysics Data System (ADS)

    Mazlan, Afidatusshimah; Daniyal, Hamdan; Izzani Mohamed, Amir; Ishak, Mahadzir; Hadi, Amran Abdul

    2017-10-01

    Qualities of welding play an important part in industry especially in manufacturing field. Post-welding non-destructive test is one of the importance process to ensure the quality of welding but it is time consuming and costly. To reduce the chance of defects, online monitoring had been utilized by continuously sense some of welding parameters and predict welding quality. One of the parameters is welding current, which is rich of information but lack of study focus on extract them at signal analysis level. This paper presents the analysis of welding current using Short Time Energy (STE) signal processing to quantify the pattern of the current. GMAW set with carbon steel specimens are used in this experimental study with high-bandwidth and high sampling rate oscilloscope capturing the welding current. The results indicate welding current as signatures have high correlation with the welding process. Continue with STE analysis, the value below 5000 is declare as good welding, meanwhile the STE value more than 6000 is contained defect.

  6. For Video Games, Bad News Is Good News: News Reporting of Violent Video Game Studies.

    PubMed

    Copenhaver, Allen; Mitrofan, Oana; Ferguson, Christopher J

    2017-12-01

    News coverage of video game violence studies has been critiqued for focusing mainly on studies supporting negative effects and failing to report studies that did not find evidence for such effects. These concerns were tested in a sample of 68 published studies using child and adolescent samples. Contrary to our hypotheses, study effect size was not a predictor of either newspaper coverage or publication in journals with a high-impact factor. However, a relationship between poorer study quality and newspaper coverage approached significance. High-impact journals were not found to publish studies with higher quality. Poorer quality studies, which tended to highlight negative findings, also received more citations in scholarly sources. Our findings suggest that negative effects of violent video games exposure in children and adolescents, rather than large effect size or high methodological quality, increase the likelihood of a study being cited in other academic publications and subsequently receiving news media coverage.

  7. Methodological quality of systematic reviews on influenza vaccination.

    PubMed

    Remschmidt, Cornelius; Wichmann, Ole; Harder, Thomas

    2014-03-26

    There is a growing body of evidence on the risks and benefits of influenza vaccination in various target groups. Systematic reviews are of particular importance for policy decisions. However, their methodological quality can vary considerably. To investigate the methodological quality of systematic reviews on influenza vaccination (efficacy, effectiveness, safety) and to identify influencing factors. A systematic literature search on systematic reviews on influenza vaccination was performed, using MEDLINE, EMBASE and three additional databases (1990-2013). Review characteristics were extracted and the methodological quality of the reviews was evaluated using the assessment of multiple systematic reviews (AMSTAR) tool. U-test, Kruskal-Wallis test, chi-square test, and multivariable linear regression analysis were used to assess the influence of review characteristics on AMSTAR-score. Fourty-six systematic reviews fulfilled the inclusion criteria. Average methodological quality was high (median AMSTAR-score: 8), but variability was large (AMSTAR range: 0-11). Quality did not differ significantly according to vaccination target group. Cochrane reviews had higher methodological quality than non-Cochrane reviews (p=0.001). Detailed analysis showed that this was due to better study selection and data extraction, inclusion of unpublished studies, and better reporting of study characteristics (all p<0.05). In the adjusted analysis, no other factor, including industry sponsorship or journal impact factor had an influence on AMSTAR score. Systematic reviews on influenza vaccination showed large differences regarding their methodological quality. Reviews conducted by the Cochrane collaboration were of higher quality than others. When using systematic reviews to guide the development of vaccination recommendations, the methodological quality of a review in addition to its content should be considered. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Additive effect of calcium depletion and low resource quality on Gammarus fossarum (Crustacea, Amphipoda) life history traits.

    PubMed

    Rollin, Marc; Coulaud, Romain; Danger, Michael; Sohm, Bénédicte; Flayac, Justine; Bec, Alexandre; Chaumot, Arnaud; Geffard, Olivier; Felten, Vincent

    2018-04-01

    Gammarus fossarum is an often-abundant crustacean detritivore that contributes importantly to leaf litter breakdown in oligotrophic, mainly heterotrophic, headwater streams. This species requires large amounts of Ca to moult, thus allowing growth and reproduction. Because resource quality is tightly coupled to the organism's growth and physiological status, we hypothesised that low Ca concentration [Ca] and low food resource quality (low phosphorus [P] and/or reduced highly unsaturated fatty acid [HUFA] contents) would interactively impair molecular responses (gene expression) and reproduction of G. fossarum. To investigate the effects of food resources quality, we experimentally manipulated the P content of sycamore leaves and also used diatoms because they contain high amounts of HUFAs. Three resource quality treatments were tested: low quality (LQ, unmanipulated leaves: low P content), high quality 1 (HQ1; P-manipulated leaves: high P content), and high quality 2 (unmanipulated leaves supplemented with a pellet containing diatoms: high P and HUFA content). Naturally, demineralised stream water was supplemented with CaSO 4 to obtain three Ca concentrations (2, 3.5, and 10.5 mg Ca L -1 ). For 21 days, pairs of G. fossarum were individually exposed to one of the nine treatments (3 [Ca] × 3 resource qualities). At the individual level, strong and significant delays in moult stage were observed in gammarids exposed to lower [Ca] and to lower resource quality, with additive effects lengthening the duration of the reproductive cycle. Effects at the molecular level were investigated by measuring expression of 12 genes involved in energy production, translation, or Ca or P homeostasis. Expression of ATP synthase beta (higher in HQ2), calcified cuticle protein (higher in HQ1 and HQ2), and tropomyosin (higher in HQ2 compared to HQ1) was significantly affected by resource quality, and significant additive effects on Ca transporting ATPase expression were induced by [Ca] and resource quality (higher for low [Ca] and higher resource quality). These results highlight the potential drastic deleterious effects of water [Ca] depletion on G. fossarum physiology, populations, and ecosystem functioning, especially in oligotrophic environments.

  9. A systematic review of the diagnostic accuracy of provocative tests of the neck for diagnosing cervical radiculopathy

    PubMed Central

    Pool, Jan J. M.; van Tulder, Maurits W.; Riphagen, Ingrid I.; de Vet, Henrica C. W.

    2006-01-01

    Clinical provocative tests of the neck, which position the neck and arm inorder to aggravate or relieve arm symptoms, are commonly used in clinical practice in patients with a suspected cervical radiculopathy. Their diagnostic accuracy, however, has never been examined in a systematic review. A comprehensive search was conducted in order to identify all possible studies fulfilling the inclusion criteria. A study was included if: (1) any provocative test of the neck for diagnosing cervical radiculopathy was identified; (2) any reference standard was used; (3) sensitivity and specificity were reported or could be (re-)calculated; and, (4) the publication was a full report. Two reviewers independently selected studies, and assessed methodological quality. Only six studies met the inclusion criteria, which evaluated five provocative tests. In general, Spurling’s test demonstrated low to moderate sensitivity and high specificity, as did traction/neck distraction, and Valsalva’s maneuver. The upper limb tension test (ULTT) demonstrated high sensitivity and low specificity, while the shoulder abduction test demonstrated low to moderate sensitivity and moderate to high specificity. Common methodological flaws included lack of an optimal reference standard, disease progression bias, spectrum bias, and review bias. Limitations include few primary studies, substantial heterogeneity, and numerous methodological flaws among the studies; therefore, a meta-analysis was not conducted. This review suggests that, when consistent with the history and other physical findings, a positive Spurling’s, traction/neck distraction, and Valsalva’s might be indicative of a cervical radiculopathy, while a negative ULTT might be used to rule it out. However, the lack of evidence precludes any firm conclusions regarding their diagnostic value, especially when used in primary care. More high quality studies are necessary in order to resolve this issue. PMID:17013656

  10. Properties of High Strength Concrete Applied on Semarang - Bawen Highway

    NASA Astrophysics Data System (ADS)

    Setiyawan, Prabowo; Antonius; Wedyowibowo, R. Hawik Jenny

    2018-04-01

    To fulfill the needs of highway construction then a high quality concrete is expected to be produced by a short time and high workability, therefore the addition of additive chemicals needs to be conducted. The objective of the study was to find out the properties of high quality concrete including slump value, compressive strength, flexural strength, elasticity modulus and stress-strain diagrams with the addition of fly ash and superplasticizer. There were five types of mixtures were made in this study with a fas (cement water factor) was 0,41 and an additional 15% of fly ash and a varied superplasticizer of 0%, 0.5%, 1%, 2% towards the weight/volume and cement/water. Test samples of cylinders and prisms or beams were tested in the laboratory at 1, 3, 7, 14, and 28 days. The test results were then compared with the test results made without additional additives. Based on the result of this research, it can be concluded that the increase of slump value due to the addition of 15% fly ash is 0,53 cm of the base slump value. The use of superplasticizer causes the weight of the type to be greater. The optimum dose of superplasticizer is 1,2%, it is still in the usage level according to the F-type admixture brochure (water reducing, high-range admixture) such as 0,6 % -1,5 %. All mixture types which use addition materials for flexural strength (fr'=45kg/cm2) can be achieved at 3 days.

  11. Quality Audit in the Fastener Industry

    NASA Technical Reports Server (NTRS)

    Reagan, John R.

    1995-01-01

    Both the financial and quality communities rely on audits to verify customers records. The financial community is highly structured around three categories of risk, INHERENT RISK, CONTROL RISK, and DETECTION RISK. Combined, the product of these three categories constitute the AUDIT RISK. The financial community establishes CONTROL RISK based in large part on a systems level understanding of the process flow. This system level understanding is best expressed in a flowchart. The quality community may be able to adopt this structure and thereby reduce cost while maintaining and enhancing quality. The quality community should attempt to flowchart the systems level quality process before beginning substantive testing. This theory needs to be applied in several trial cases to prove or disprove this hypothesis

  12. Quality audit in the fastener industry

    NASA Astrophysics Data System (ADS)

    Reagan, John R.

    1995-09-01

    Both the financial and quality communities rely on audits to verify customers records. The financial community is highly structured around three categories of risk, INHERENT RISK, CONTROL RISK, and DETECTION RISK. Combined, the product of these three categories constitute the AUDIT RISK. The financial community establishes CONTROL RISK based in large part on a systems level understanding of the process flow. This system level understanding is best expressed in a flowchart. The quality community may be able to adopt this structure and thereby reduce cost while maintaining and enhancing quality. The quality community should attempt to flowchart the systems level quality process before beginning substantive testing. This theory needs to be applied in several trial cases to prove or disprove this hypothesis

  13. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  14. D Imaging for Museum Artefacts: a Portable Test Object for Heritage and Museum Documentation of Small Objects

    NASA Astrophysics Data System (ADS)

    Hess, M.; Robson, S.

    2012-07-01

    3D colour image data generated for the recording of small museum objects and archaeological finds are highly variable in quality and fitness for purpose. Whilst current technology is capable of extremely high quality outputs, there are currently no common standards or applicable guidelines in either the museum or engineering domain suited to scientific evaluation, understanding and tendering for 3D colour digital data. This paper firstly explains the rationale towards and requirements for 3D digital documentation in museums. Secondly it describes the design process, development and use of a new portable test object suited to sensor evaluation and the provision of user acceptance metrics. The test object is specifically designed for museums and heritage institutions and includes known surface and geometric properties which support quantitative and comparative imaging on different systems. The development for a supporting protocol will allow object reference data to be included in the data processing workflow with specific reference to conservation and curation.

  15. Artificial enzyme-powered microfish for water-quality testing.

    PubMed

    Orozco, Jahir; García-Gradilla, Victor; D'Agostino, Mattia; Gao, Wei; Cortés, Allan; Wang, Joseph

    2013-01-22

    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC(50) (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing.

  16. SU-F-J-26: Performance of 2.5MV Portal Imaging in Comparison with KV X-Ray and 6MV and Flattening-Filter-Free 6MV Portal Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duan, J; Yang, Y; Faught, A

    Purpose: To assess image quality and imaging dose of 2.5MV electronic portal imaging in comparison to kV imaging and 6MV and Flattening-Filter-Free 6MV (6MVFFF) portal imaging using a DMI imager. Methods: Quantitative assessment of image quality was performed with Leeds and Las Vegas test phantoms in conjunction with qualitative evaluation of clinical patient images for kV imaging and 2.5MV, 6MV and 6MVFFF portal imaging. High and low contrast resolutions were evaluated and imaging doses were measured using these x-rays. Phantom test was performed both in air and in solid water. Clinical patient portal images were also reviewed and qualitatively assessedmore » for these three imaging MV energies. Results: Among the 28 objects in Las Vegas phantom, 16, 17 and 26 of them were resolved using Low Dose technique and 18, 22 and 26 were resolved using High Quality technique with 6MV, 6MVFFF and 2.5MV, respectively. The number of Leeds low contrast objects resolved by 6MV, 6MFFFF and 2.5MV was 6, 15 and 18 with Low Dose technique and 14, 17 and 18 with High Quality technique, respectively. When the test phantoms were embedded in 20cm thick solid water, the results were noticeably affected, but the performance of 2.5MV was still substantially better than 6MV and 6MVFFF. Imaging dose with 2.5MV measured at 10 cm depth was about half of that with 6MV or 6MVFFF. Clinical patient portal images were reviewed and qualitatively assessed for different sites including brain, head-and-neck, chest and pelvis. 2.5MV imaging provided more details and substantially higher contrast. Conclusion: While portal imaging with 6MVFFF provides noticeably better image quality than that with 6MV, the performance of 2.5MV portal imaging is substantially better than both 6MV and 6MVFFF in terms of high and low contrast resolutions as well as lower imaging dose. 2.5MV imaging provides near kV imaging quality.« less

  17. Science Labs: Beyond Isolationism

    ERIC Educational Resources Information Center

    Cavanagh, Sean

    2007-01-01

    A national study released in 2005 concluded that most high school students are not exposed to high quality science labs because of these reasons: (a) poor school facilities and organizations; (b) weak teacher preparation; (c) poor design; (d) cluttered state standards; (e) little representation on state tests; and (f) scarce evidence of what…

  18. Research on aspheric focusing lens processing and testing technology in the high-energy laser test system

    NASA Astrophysics Data System (ADS)

    Liu, Dan; Fu, Xiu-hua; Jia, Zong-he; Wang, Zhe; Dong, Huan

    2014-08-01

    In the high-energy laser test system, surface profile and finish of the optical element are put forward higher request. Taking a focusing aspherical zerodur lens with a diameter of 100mm as example, using CNC and classical machining method of combining surface profile and surface quality of the lens were investigated. Taking profilometer and high power microscope measurement results as a guide, by testing and simulation analysis, process parameters were improved constantly in the process of manufacturing. Mid and high frequency error were trimmed and improved so that the surface form gradually converged to the required accuracy. The experimental results show that the final accuracy of the surface is less than 0.5μm and the surface finish is □, which fulfils the accuracy requirement of aspherical focusing lens in optical system.

  19. Coaching Quality and Teachers' Implementation of the 4Rs Social-Emotional and Literacy Curriculum: Testing the Link between Two Levels of Intervention Fidelity

    ERIC Educational Resources Information Center

    Downer, Jason; Brown, Josh; Herrera, Manuela Jimenez; Stuhlman, Megan; Bourassa, Kyle; Gologor, Ben; Wong, Pamela

    2013-01-01

    Teacher-educators and policy-makers recognize that ongoing training and support for high quality implementation of curricula can be a vital component of systems that ensure the value of education experiences, particularly for students at-risk of school failure (Meisels, 2007; Pew Charitable Trusts, 2007; Pianta, 2005). In particular, there is…

  20. Robotic Telesurgery Research

    DTIC Science & Technology

    2010-03-01

    piece of tissue. Full Mobility Manipulator Robot The primary challenge with the design of a full mobility robot is meeting the competing design...streamed through an embedded plug-in for VLC player using asf/wmv encoding with 200ms buffering. A benchtop test of the remote user interface was...encountered in ensuring quality video is being made available to the surgeon. A significant challenge has been to consistently provide high quality video

  1. MRPrimerW: a tool for rapid design of valid high-quality primers for multiple target qPCR experiments

    PubMed Central

    Kim, Hyerin; Kang, NaNa; An, KyuHyeon; Koo, JaeHyung; Kim, Min-Soo

    2016-01-01

    Design of high-quality primers for multiple target sequences is essential for qPCR experiments, but is challenging due to the need to consider both homology tests on off-target sequences and the same stringent filtering constraints on the primers. Existing web servers for primer design have major drawbacks, including requiring the use of BLAST-like tools for homology tests, lack of support for ranking of primers, TaqMan probes and simultaneous design of primers against multiple targets. Due to the large-scale computational overhead, the few web servers supporting homology tests use heuristic approaches or perform homology tests within a limited scope. Here, we describe the MRPrimerW, which performs complete homology testing, supports batch design of primers for multi-target qPCR experiments, supports design of TaqMan probes and ranks the resulting primers to return the top-1 best primers to the user. To ensure high accuracy, we adopted the core algorithm of a previously reported MapReduce-based method, MRPrimer, but completely redesigned it to allow users to receive query results quickly in a web interface, without requiring a MapReduce cluster or a long computation. MRPrimerW provides primer design services and a complete set of 341 963 135 in silico validated primers covering 99% of human and mouse genes. Free access: http://MRPrimerW.com. PMID:27154272

  2. Vanguard/PLACE experiment system design and test plan

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.

    1973-01-01

    A system design and test plan are described for operational evaluation of the NASA-Goddard position location and aircraft communications equipment (PLACE), at C band (4/6GHz), using NASA's ship, the USNS Vanguard, and the ATS 3 and ATS 5 synchronous satellites. The Sea Test phase, extending from March 29, 1973 to April 15, 1973 was successfully completed; the principal objectives of the experiment were achieved. Typical PLACE-computed, position-location data is shown for the Vanguard. Position location and voice-quality measurements were excellent; ship position was determined within 2 nmi; high-quality, 2-way voice transmissions resulted as determined from audience participation, intelligibility and articulation-index analysis. A C band/L band satellite trilateration experiment is discussed.

  3. Second Generation International Space Station (ISS) Total Organic Carbon Analyzer (TOCA) Verification Testing and On-Orbit Performance Results

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole L.; Thomas, Evan A.; VanWie, Michael; Morrison, Chad; Stinson, Richard G.

    2010-01-01

    The Total Organic Carbon Analyzer (TOGA) is designed to autonomously determine recovered water quality as a function of TOC. The current TOGA has been on the International Space Station since November 2008. Functional checkout and operations revealed complex operating considerations. Specifically, failure of the hydrogen catalyst resulted in the development of an innovative oxidation analysis method. This method reduces the activation time and limits the hydrogen produced during analysis, while retaining the ability to indicate TOC concentrations within 25% accuracy. Subsequent testing and comparison to archived samples returned from the Station and tested on the ground yield high confidence in this method, and in the quality of the recovered water.

  4. Comparison of different methods for radiochemical purity testing of [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide.

    PubMed

    von Guggenberg, Elisabeth; Penz, Barbara; Kemmler, Georg; Virgolini, Irene; Decristoforo, Clemens

    2006-02-01

    [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide (99mTc-EDDA-HYNIC-TOC) is an alternative radioligand for somatostatin receptor (SSTR) scintigraphy of neuroendocrine tumours. In order to allow a rapid and accurate determination of the quality in the clinical routine the aim of this study was to evaluate different methods of radiochemical purity (RCP) testing. Three different methods of RCP testing were compared: high-performance liquid chromatography (HPLC), thin layer chromatography (TLC) and minicolumn (Sep-Pak purification = SPE). HPLC was shown to be the most effective method for the quality control. The use of TLC and SPE is only recommended after sufficient practical labelling experience.

  5. Improving quality in the preanalytical phase through innovation, on behalf of the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE).

    PubMed

    Lippi, Giuseppe; Baird, Geoffrey S; Banfi, Giuseppe; Bölenius, Karin; Cadamuro, Janne; Church, Stephen; Cornes, Michael P; Dacey, Anna; Guillon, Antoine; Hoffmann, Georg; Nybo, Mads; Premawardhana, Lakdasa Devananda; Salinas, María; Sandberg, Sverre; Slingerland, Robbert; Stankovic, Ana; Sverresdotter, Sylte Marit; Vermeersch, Pieter; Simundic, Ana-Maria

    2017-03-01

    It is now undeniable that laboratory testing is vital for the diagnosis, prognostication and therapeutic monitoring of human disease. Despite the many advances made for achieving a high degree of quality and safety in the analytical part of diagnostic testing, many hurdles in the total testing process remain, especially in the preanalytical phase ranging from test ordering to obtaining and managing the biological specimens. The Working Group for the Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has planned many activities aimed at mitigating the vulnerability of the preanalytical phase, including the organization of three European meetings in the past 7 years. Hence, this collective article follows the previous three opinion papers that were published by the EFLM WGPRE on the same topic, and brings together the summaries of the presentations that will be given at the 4th EFLM-BD meeting "Improving quality in the preanalytical phase through innovation" in Amsterdam, 24-25 March, 2017.

  6. The association of quality of social relations, symptom severity and intelligence with anxiety in children with autism spectrum disorders.

    PubMed

    Eussen, Mart L J M; Van Gool, Arthur R; Verheij, Fop; De Nijs, Pieter F A; Verhulst, Frank C; Greaves-Lord, Kirstin

    2013-11-01

    Limited quality of social relations, milder symptom severity and higher intelligence were shown to account for higher anxiety levels in autism spectrum disorders. The current study replicated and extended earlier findings by combining these three determinants of anxiety in autism spectrum disorders in one study. The sample consisted of 134 school-aged children with autism spectrum disorders, of whom 58 (43%) had a co-morbid anxiety disorder according to the Diagnostic Interview Schedule for Children-Parent version. In this sample, we tested associations between these determinants and anxiety univariately and multivariately to clarify the unique contribution of all determinants. Since we hypothesized that the association between limited quality of social relations and anxiety would be amplified by low symptom severity and/or high intelligence, we additionally tested for moderating effects. We found that higher anxiety levels were associated with a lower quality of social relations and lower symptom severity. In this mainly high-functioning sample, intelligence was not related to anxiety levels. No moderation effects were found. Since lower quality of social relations and lower symptom severity are associated with higher anxiety levels in children with autism spectrum disorders, therapeutic interventions aimed at reducing anxiety in autism spectrum disorders should pay attention to improving social relations, and presumably children with a lower symptom severity could benefit most from such interventions.

  7. Water monitor system: Phase 1 test report

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Jeffers, E. L.

    1976-01-01

    Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.

  8. 24 CFR 200.935 - Administrator qualifications and procedures for HUD building products certification programs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... guidelines in any quality assurance review: (1) ASQC Q9000-1-1994 Quality Management and Quality Assurance... Systems—Model for Quality Assurance in Final Inspection and Test; (5) ASQC Q9004-1-1994 Quality Management... in interpreting testing standards, test methods, evaluating test reports and quality control programs...

  9. Vitamin D Improves Selected Metabolic Parameters but Not Neuropsychological or Quality of Life Indices in OSA: A Pilot Study.

    PubMed

    Kerley, Conor P; Hutchinson, Katrina; Bramham, Jessica; McGowan, Aisling; Faul, John; Cormican, Liam

    2017-01-15

    Our group and others have reported a high rate of vitamin D deficiency in obstructive sleep apnea (OSA), where vitamin D levels (25(OH) D) correlate negatively with OSA severity and some of its associated metabolic alterations. Data regarding vitamin D supplementation in OSA are lacking. We wanted to evaluate the effect of vitamin D 3 supplementation on OSA symptoms and metabolic parameters. We conducted a pilot, double-blind, randomized, placebo-controlled trial of daily supplementation with 4,000 IU vitamin D 3 (D3) or placebo (PL). We studied 19 Caucasian adults (14 male, mean age 55 y, mean body mass index [BMI] 30.4 kg/m 2 ) with OSA. Fifteen patients were stable on continuous positive airways pressure (CPAP) therapy, whereas four were CPAP naïve. Assessments were completed at baseline and after 15 weeks of supplementation. Outcomes included sleepiness (Epworth Sleepiness Scale), quality of life (Sleep Apnea Quality of Life Inventory), fatigue (fatigue severity scale) and neuropsychological function (trail making test and Connor's Continuous Performance Test II). In addition, we assessed biochemical indices of vitamin D status (25(OH)D, calcium), inflammation (high sensitivity C-reactive protein, and lipoprotein-associated phospholipase A2), lipids (total cholesterol [low-density and high-density lipoprotein]) and glycemic indices (fasting glucose, oral glucose tolerance test). There was no change in BMI, medication, or CPAP usage. Although there was no change in neuropsychological or quality of life indices, we observed a significant increase in 25(OH)D (p = 0.00001) and significant decreases in both low-density lipoprotein (p = 0.04) and lipoprotein-associated phospholipase A2 (p = 0.037) as well as trends toward decreased fasting glucose (p = 0.09) and increased high-density lipoprotein (p = 0.07) in the D 3 group compared to PL. Vitamin D 3 supplementation increased vitamin D levels and decreased metabolic markers compared to placebo. Larger trials are required. © 2017 American Academy of Sleep Medicine

  10. A Systematic Review of Genetic Testing and Lifestyle Behaviour Change: Are We Using High-Quality Genetic Interventions and Considering Behaviour Change Theory?

    PubMed

    Horne, Justine; Madill, Janet; O'Connor, Colleen; Shelley, Jacob; Gilliland, Jason

    2018-04-10

    Studying the impact of genetic testing interventions on lifestyle behaviour change has been a priority area of research in recent years. Substantial heterogeneity exists in the results and conclusions of this literature, which has yet to be explained using validated behaviour change theory and an assessment of the quality of genetic interventions. The theory of planned behaviour (TPB) helps to explain key contributors to behaviour change. It has been hypothesized that personalization could be added to this theory to help predict changes in health behaviours. This systematic review provides a detailed, comprehensive identification, assessment, and summary of primary research articles pertaining to lifestyle behaviour change (nutrition, physical activity, sleep, and smoking) resulting from genetic testing interventions. The present review further aims to provide in-depth analyses of studies conducted to date within the context of the TPB and the quality of genetic interventions provided to participants while aiming to determine whether or not genetic testing facilitates changes in lifestyle habits. This review is timely in light of a recently published "call-to-action" paper, highlighting the need to incorporate the TPB into personalized healthcare behaviour change research. Three bibliographic databases, one key website, and article reference lists were searched for relevant primary research articles. The PRISMA Flow Diagram and PRISMA Checklist were used to guide the search strategy and manuscript preparation. Out of 32,783 titles retrieved, 26 studies met the inclusion criteria. Three quality assessments were conducted and included: (1) risk of bias, (2) quality of genetic interventions, and (3) consideration of theoretical underpinnings - primarily the TPB. Risk of bias in studies was overall rated to be "fair." Consideration of the TPB was "poor," with no study making reference to this validated theory. While some studies (n = 11; 42%) made reference to other behaviour change theories, these theories were generally mentioned briefly, and were not thoroughly incorporated into the study design or analyses. The genetic interventions provided to participants were overall of "poor" quality. However, a separate analysis of studies using controlled intervention research methods demonstrated the use of higher-quality genetic interventions (overall rated to be "fair"). The provision of actionable recommendations informed by genetic testing was more likely to facilitate behaviour change than the provision of genetic information without actionable lifestyle recommendations. Several studies of good quality demonstrated changes in lifestyle habits arising from the provision of genetic interventions. The most promising lifestyle changes were changes in nutrition. It is possible to facilitate behaviour change using genetic testing as the catalyst. Future research should ensure that high-quality genetic interventions are provided to participants, and should consider validated theories such as the TPB in their study design and analyses. Further recommendations for future research are provided. © 2018 S. Karger AG, Basel.

  11. Cellscope Aquatic: a Lab Quality, Portable Cellphone-Based Microscope for On-Site Collection of Algae Images

    NASA Astrophysics Data System (ADS)

    Steinberg, S. J.; Howard, M. D.

    2016-02-01

    Collecting algae samples from the field presents issues of specimen damage or degradation caused by preservation methods, handling and transport to laboratory facilities for identification. Traditionally, in-field collection of high quality microscopic images has not been possible due to the size, weight and fragility of high quality instruments and training of field staff in species identification. Scientists at the Southern California Coastal Water Research Project (SCCWRP) in collaboration with the Fletcher Lab, University of California Berkeley, Department of Bioengineering, tested and translated Fletcher's original medical CellScope for use in environmental monitoring applications. Field tests conducted by SCCWRP in 2014 led to modifications of the clinical CellScope to one better suited to in-field microscopic imaging for aquatic organisms. SCCWRP subsequently developed a custom cell-phone application to acquire microscopic imagery using the "CellScope Aquatic "in combination with other cell-phone derived field data (e.g. GPS location, date, time and other field observations). Data and imagery collected in-field may be transmitted in real-time to a web-based data system for tele-taxonomy evaluation and assessment by experts in the office. These hardware and software tools was tested in field in a variety of conditions and settings by multiple algae experts during the spring and summer of 2015 to further test and refine the CellScope Aquatic platform. The CellScope Aquatic provides an easy-to-use, affordable, lightweight, professional quality, data collection platform for environmental monitoring. Our ongoing efforts will focus on development of real-time expert systems for data analysis and image processing, to provide onsite feedback to field scientists.

  12. Systematic review of the quality and generalizability of studies on the effects of opioids on driving and cognitive/psychomotor performance.

    PubMed

    Mailis-Gagnon, Angela; Lakha, Shehnaz Fatima; Furlan, Andrea; Nicholson, Keith; Yegneswaran, Balaji; Sabatowski, Rainer

    2012-07-01

    The effect of opioids on driving performance has been much debated. Driving is a complex task requiring integration of psychomotor, cognitive, motor and decision-making skills, visual-spatial abilities, divided attention, and behavioral and emotional control. The objective of this systematic review was to assess the quality of studies and to revisit the concept that patients on stable opioids are safe to drive as it applies to everyday practice. We searched MEDLINE, EMBASE, PSYCinfo, CENTRAL, TRANSPORT, CINAHL, reference lists of retrieved articles and narrative reviews, for studies on chronic cancer and noncancer pain patients on opioids, tested by driving, driving simulator, or cognitive/psychomotor tests. Methodological quality was assessed with Methodological Index for Nonrandomized Studies, cognitive/psychomotor tests were appraised regarding their sensitivity and validation, and whether confounding variables potentially affecting the study conclusions were recorded. The results were analyzed both quantitatively and qualitatively. We included 35 studies (2044 patients, 1994 controls), 9% of the studies were of poor, 54% of fair, and 37% of high quality; 3 quarters of the studies used high sensitivity cognitive tests. Amount and dose of opioids varied largely in many studies. Mean number of possible but unreported confounders was 2.2 (range, 0 to 4), relating to failure of the studies to mention co-prescriptions with psychotropic effects, pain severity, sleep disorder or daytime somnolence, and/or significant depressive or anxiety-related problems. The commonly held concept that "chronic pain patients on stable opioids are safe to drive" cannot be generalized to all such patients in everyday practice, but may be applicable only to a subset who meet certain criteria.

  13. [Evaluation of the quality of three-dimensional data acquired by using two kinds of structure light intra-oral scanner to scan the crown preparation model].

    PubMed

    Zhang, X Y; Li, H; Zhao, Y J; Wang, Y; Sun, Y C

    2016-07-01

    To quantitatively evaluate the quality and accuracy of three-dimensional (3D) data acquired by using two kinds of structure intra-oral scanner to scan the typical teeth crown preparations. Eight typical teeth crown preparations model were scanned 3 times with two kinds of structured light intra-oral scanner(A, B), as test group. A high precision model scanner were used to scan the model as true value group. The data above the cervical margin was extracted. The indexes of quality including non-manifold edges, the self-intersections, highly-creased edges, spikes, small components, small tunnels, small holes and the anount of triangles were measured with the tool of mesh doctor in Geomagic studio 2012. The scanned data of test group were aligned to the data of true value group. 3D deviations of the test group compared with true value group were measured for each scanned point, each preparation and each group. Independent-samples Mann-Whitney U test was applied to analyze 3D deviations for each scanned point of A and B group. Correlation analysis was applied to index values and 3D deviation values. The total number of spikes in A group was 96, and that in B group and true value group were 5 and 0 respectively. Trueness: A group 8.0 (8.3) μm, B group 9.5 (11.5) μm(P>0.05). Correlation analysis of the number of spikes with data precision of A group was r=0.46. In the study, the qulity of the scanner B is better than scanner A, the difference of accuracy is not statistically significant. There is correlation between quality and data precision of the data scanned with scanner A.

  14. Qualitative evaluations and comparisons of six night-vision colorization methods

    NASA Astrophysics Data System (ADS)

    Zheng, Yufeng; Reese, Kristopher; Blasch, Erik; McManamon, Paul

    2013-05-01

    Current multispectral night vision (NV) colorization techniques can manipulate images to produce colorized images that closely resemble natural scenes. The colorized NV images can enhance human perception by improving observer object classification and reaction times especially for low light conditions. This paper focuses on the qualitative (subjective) evaluations and comparisons of six NV colorization methods. The multispectral images include visible (Red-Green- Blue), near infrared (NIR), and long wave infrared (LWIR) images. The six colorization methods are channel-based color fusion (CBCF), statistic matching (SM), histogram matching (HM), joint-histogram matching (JHM), statistic matching then joint-histogram matching (SM-JHM), and the lookup table (LUT). Four categries of quality measurements are used for the qualitative evaluations, which are contrast, detail, colorfulness, and overall quality. The score of each measurement is rated from 1 to 3 scale to represent low, average, and high quality, respectively. Specifically, high contrast (of rated score 3) means an adequate level of brightness and contrast. The high detail represents high clarity of detailed contents while maintaining low artifacts. The high colorfulness preserves more natural colors (i.e., closely resembles the daylight image). Overall quality is determined from the NV image compared to the reference image. Nine sets of multispectral NV images were used in our experiments. For each set, the six colorized NV images (produced from NIR and LWIR images) are concurrently presented to users along with the reference color (RGB) image (taken at daytime). A total of 67 subjects passed a screening test ("Ishihara Color Blindness Test") and were asked to evaluate the 9-set colorized images. The experimental results showed the quality order of colorization methods from the best to the worst: CBCF < SM < SM-JHM < LUT < JHM < HM. It is anticipated that this work will provide a benchmark for NV colorization and for quantitative evaluation using an objective metric such as objective evaluation index (OEI).

  15. Physiological behavior of bean's seeds and grains during storage.

    PubMed

    Cassol, Flávia D R; Fortes, Andréa M T; Mendonça, Lorena C; Buturi, Camila V; Marcon, Thaís R

    2016-05-31

    Beans are one of the most used foods to meet the energy needs of the Brazilian diet, requiring farmers to use high seed physiological potential. The aim was to evaluate the physiological quality of beans stored for 360 days. Analyses were performed at 0, 30, 90, 180, 270, and 360 days after receiving the seeds (S1 and S2) and grains (G1 and G2) of BRS Splendor. Tests of germination, accelerated aging, cold, speed of germination, average length of shoots, and root were performed. The experimental design was completely randomized split-plot in time and the means were compared through Tukey test at 5% probability. Seed germination was not affected in S2, while the drop in S1 and G1 was significant. The vigor of grains from field 1 declined from 91 to 50% and from 93% to 76% by accelerated aging and cold, respectively, after 360 days. The germination speed tests performed showed a decreased during the experiment. The grains from field 1 had lower physiological quality. The accelerated aging and cold tests, through the speed of germination parameter, showed decrease in the vigor of the Splendor BRS. The storage period influenced the physiological quality of the beans tested.

  16. Quality assuring HIV point of care testing using whole blood samples.

    PubMed

    Dare-Smith, Raellene; Badrick, Tony; Cunningham, Philip; Kesson, Alison; Badman, Susan

    2016-08-01

    The Royal College of Pathologists Australasia Quality Assurance Programs (RCPAQAP), have offered dedicated external quality assurance (EQA) for HIV point of care testing (PoCT) since 2011. Prior to this, EQA for these tests was available within the comprehensive human immunodeficiency virus (HIV) module. EQA testing for HIV has typically involved the supply of serum or plasma, while in the clinic or community based settings HIV PoCT is generally performed using whole blood obtained by capillary finger-stick collection. RCPAQAP has offered EQA for HIV PoCT using stabilised whole blood since 2014. A total of eight surveys have been undertaken over a period of 2 years from 2014 to 2015. Of the 962 responses received, the overall consensus rate was found to be 98% (941/962). A total of 21 errors were detected. The majority of errors were attributable to false reactive HIV p24 antigen results (9/21, 43%), followed by false reactive HIV antibody results (8/21, 38%). There were 4/21 (19%) false negative HIV antibody results and no false negative HIV p24 antigen results reported. Overall performance was observed to vary minimally between surveys, from a low of 94% up to 99% concordant. Encouraging levels of testing proficiency for HIV PoCT are indicated by these data, but they also confirm the need for HIV PoCT sites to participate in external quality assurance programs to ensure the ongoing provision of high quality patient care. Copyright © 2016 Royal College of Pathologists of Australasia. All rights reserved.

  17. The comparison of high and standard definition computed tomography techniques regarding coronary artery imaging.

    PubMed

    Aykut, Aktas; Bumin, Degirmenci; Omer, Yilmaz; Mustafa, Kayan; Meltem, Cetin; Orhan, Celik; Nisa, Unlu; Hikmet, Orhan; Hakan, Demirtas; Mert, Koroglu

    2015-09-01

    The aim was to compare coronary high-definition CT (HDCT) with standard-definition CT (SDCT) angiography as to radiation dose, image quality and accuracy. 28 patients with history of coronary artery disease scanned by HDCT (Discovery CT750 HD) and SDCT (Somatom Definition AS). The scan modes were both axial prospective ECG-triggered. The vessel diameters and vessel attenuation values of totally 280 measurements from 140 coronary arteries were analyzed by two experienced radiologists. All data was analyzed by intraclass correlation test. Image quality graded by motion and stair step artifacts (grade 1, poor, to grade 4, excellent), accuracy of vessel inner and outer diameters were compared between the two CT units using the independent samples t-test and Mann-Whitney U test. The intraclass correlation coefficient (ICC) of measured vessel attenuation values in SDCT between the two radiologists was exceedingly good. The ICC was higher in HDCT. The radiation dose of HDCT was higher than that of SDCT. The mean tube current was 180 (mA) in HDCT and 147(mA) in SDCT with the same tube voltage (kVp). There was no significant difference between image quality. HDCT has a higher radiation dose but has much more atenuation and the spatial resolution which improve measurement accuracy for imaging coronary arteries.

  18. Can fitness and movement quality prevent back injury in elite task force police officers? A 5-year longitudinal study.

    PubMed

    McGill, Stuart; Frost, David; Lam, Thomas; Finlay, Tim; Darby, Kevin; Cannon, Jordan

    2015-01-01

    Elite police work has bursts of intense physically demanding work requiring high levels of fitness, or capacity, and movement competency; which are assumed to increase one's injury resilience. The purpose of this study was to follow members of an elite police force (N = 53) to test whether back injuries (N = 14) could be predicted from measures of fitness and movement quality. Measures of torso endurance, relative and absolute strength, hip ROM and movement quality using the Functional Movement Screen(TM) and other dynamic movement tests were obtained from every officer at baseline. When variables were grouped and considered holistically, rather than individually, back injury could be predicted. Seven variables best predicted those who would suffer a back injury (64% sensitivity and 95% specificity for an overall concordance of 87%). Overall, the ability to predict back injury was not high, suggesting that there is more complexity to this relationship than is explained with the variables tested here. Practitioner Summary: Members of elite police forces have exposure to intense physically demanding work. Increased levels of fitness and movement competency have been assumed to increase injury resilience. However, complexity in the interactions between exposure, movement competency, training, fitness and injury may occlude the true relationship between these variables.

  19. PTERA - Modular Aircraft Flight Test

    NASA Image and Video Library

    2016-01-13

    Aerospace testing can be costly and time consuming but a new modular, subscale remotely piloted aircraft offers NASA researchers more affordable options for developing a wide range of cutting edge aviation and space technologies. The Prototype-Technology Evaluation and Research Aircraft (PTERA), developed by Area-I, Inc., of Kennesaw, Georgia, is an extremely versatile and high quality, yet inexpensive, flying laboratory bridging the gap between wind tunnels and crewed flight testing.

  20. Aircraft flight test trajectory control

    NASA Technical Reports Server (NTRS)

    Menon, P. K. A.; Walker, R. A.

    1988-01-01

    Two control law design techniques are compared and the performance of the resulting controllers evaluated. The design requirement is for a flight test trajectory controller (FTTC) capable of closed-loop, outer-loop control of an F-15 aircraft performing high-quality research flight test maneuvers. The maneuver modeling, linearization, and design methodologies utilized in this research, are detailed. The results of applying these FTTCs to a nonlinear F-15 simulation are presented.

  1. The Quality of Rare Disease Registries: Evaluation and Characterization.

    PubMed

    Coi, Alessio; Santoro, Michele; Villaverde-Hueso, Ana; Lipucci Di Paola, Michele; Gainotti, Sabina; Taruscio, Domenica; Posada de la Paz, Manuel; Bianchi, Fabrizio

    2016-01-01

    The focus on the quality of the procedures for data collection, storing, and analysis in the definition and implementation of a rare disease registry (RDR) is the basis for developing a valid and long-term sustainable tool. The aim of this study was to provide useful information for characterizing a quality profile for RDRs using an analytical approach applied to RDRs participating in the European Platform for Rare Disease Registries 2011-2014 (EPIRARE) survey. An indicator of quality was defined by choosing a small set of quality-related variables derived from the survey. The random forest method was used to identify the variables best defining a quality profile for RDRs. Fisher's exact test was employed to assess the association with the indicator of quality, and the Cochran-Armitage test was used to check the presence of a linear trend along different levels of quality. The set of variables found to characterize high-quality RDRs focused on ethical and legal issues, governance, communication of activities and results, established procedures to regulate access to data and security, and established plans to ensure long-term sustainability. The quality of RDRs is usually associated with a good oversight and governance mechanism and with durable funding. The results suggest that RDRs would benefit from support in management, information technology, epidemiology, and statistics. © 2016 S. Karger AG, Basel.

  2. Supervised and Unsupervised Self-Testing for HIV in High- and Low-Risk Populations: A Systematic Review

    PubMed Central

    Pant Pai, Nitika; Sharma, Jigyasa; Shivkumar, Sushmita; Pillay, Sabrina; Vadnais, Caroline; Joseph, Lawrence; Dheda, Keertan; Peeling, Rosanna W.

    2013-01-01

    Background Stigma, discrimination, lack of privacy, and long waiting times partly explain why six out of ten individuals living with HIV do not access facility-based testing. By circumventing these barriers, self-testing offers potential for more people to know their sero-status. Recent approval of an in-home HIV self test in the US has sparked self-testing initiatives, yet data on acceptability, feasibility, and linkages to care are limited. We systematically reviewed evidence on supervised (self-testing and counselling aided by a health care professional) and unsupervised (performed by self-tester with access to phone/internet counselling) self-testing strategies. Methods and Findings Seven databases (Medline [via PubMed], Biosis, PsycINFO, Cinahl, African Medicus, LILACS, and EMBASE) and conference abstracts of six major HIV/sexually transmitted infections conferences were searched from 1st January 2000–30th October 2012. 1,221 citations were identified and 21 studies included for review. Seven studies evaluated an unsupervised strategy and 14 evaluated a supervised strategy. For both strategies, data on acceptability (range: 74%–96%), preference (range: 61%–91%), and partner self-testing (range: 80%–97%) were high. A high specificity (range: 99.8%–100%) was observed for both strategies, while a lower sensitivity was reported in the unsupervised (range: 92.9%–100%; one study) versus supervised (range: 97.4%–97.9%; three studies) strategy. Regarding feasibility of linkage to counselling and care, 96% (n = 102/106) of individuals testing positive for HIV stated they would seek post-test counselling (unsupervised strategy, one study). No extreme adverse events were noted. The majority of data (n = 11,019/12,402 individuals, 89%) were from high-income settings and 71% (n = 15/21) of studies were cross-sectional in design, thus limiting our analysis. Conclusions Both supervised and unsupervised testing strategies were highly acceptable, preferred, and more likely to result in partner self-testing. However, no studies evaluated post-test linkage with counselling and treatment outcomes and reporting quality was poor. Thus, controlled trials of high quality from diverse settings are warranted to confirm and extend these findings. Please see later in the article for the Editors' Summary PMID:23565066

  3. Moderate-to-high normal levels of thyrotropin is a risk factor for urinary incontinence and an unsuitable quality of life in women over 65 years.

    PubMed

    Cuevas-Romero, Estela; Sánchez-Cardiel, Angélica; Zamora-Gallegos, Angélica M; Cruz-Lumbreras, Rosalía; Corona-Quintanilla, Dora L; Castelán, Francisco; Martínez-Gómez, Margarita

    2017-12-01

    The present study aimed to investigate the relationship between normal serum concentrations of thyrotropin (TSH) and urinary incontinence (IU), urinary infections, and quality of life in old women. Euthyroid post-menopausal women without sarcopenia, estrogen replacement, emotional illness, and/or cancer were enrolled as participants. Anthropometric indicators, serum glucose and estradiol, and thyroid profile were measured. Sociodemographic, clinical, physical activity, and quality of life (SF-36) surveys were applied. One-hour pad test and International Consultation on Incontinence Questionnaire Short Form (ICIQ-SF) were used to determine UI. Urinalysis was also done. In agreement with results from the pad test (cut-off point ≥1.4 g), the ICIQ-SF reveled approximately 50% of incontinent women. A high percentage of women had moderate-high bacteriuria and urinary infections. Logistic regression analysis showed that age is a risk factor for both UI and urinary infection. Diabetes, number of pregnancies or childbirths, urinary infections, and bacteriuria did not influence the presence of UI. To allocate women into four groups according to their age (<65 or ≥65 years old) and TSH concentrations (0.3-1.9 or 2-10 μUI/mL), we found that moderate-to-high normal levels of TSH is a risk factor for UI and a worse quality of life in the oldest women. Our results highlight the profit of measuring TSH concentrations in post-menopausal women. © 2017 John Wiley & Sons Australia, Ltd.

  4. The Effect of Aquatic Vegetation on Water Quality in the Everglades Agricultural Area Canals

    NASA Astrophysics Data System (ADS)

    Gomez, S. M.; Bhadha, J. H.; Lang, T. A.; Josan, M. S.; Daroub, S. H.

    2011-12-01

    The canals in the Everglades Agricultural Area contain an abundance of floating aquatic vegetation (FAV) and submerged aquatic vegetation (SAV). These FAV flourish in waters with high phosphorus (P) concentrations and prevent the co-precipitation of P with the limestone bedrock (CaCO3). To test the effects of FAV and SAV and the presence of sediments on water quality in the canals, a lysimeter study was set up and stocked with FAV (water lettuce) and SAV (filamentous algae). There were four treatments with four replicates Treatment one contained limerock, sediment from the canals, and FAV. Treatment two contained limerock, sediment, and SAV. Treatment three contained limerock and FAV, while treatment four had limerock and SAV. After 7 days, the buckets were drained and replaced the water with new, high P canal water. Water samples were taken at 0, 0.25, 1, 3, and 7 days after each weekly water exchange. To test water quality soluble reactive P, total P, total dissolved P, Ca, and total organic carbon were analyzed. The impact of FAV and SAV and canal sediments on water quality will be discussed. We hypothesize water lettuce treatments will initially result in a reduction in P-concentration in all species, but will only serve as a short-term sink because of their high turn-over rate and production of labile high-P sediment (floc). In addition, we hypothesize the treatments with no sediment will have more P reduction because of the availability for P to co-precipitate with CaCO3.

  5. Composition, quality control, and antimicrobial activity of the essential oil of long-time stored dill (Anethum graveolens L.) seeds from Bulgaria.

    PubMed

    Jirovetz, Leopold; Buchbauer, Gerhard; Stoyanova, Albena S; Georgiev, Evgenii V; Damianova, Stanka T

    2003-06-18

    The essential oil of long-time stored seeds of dill (Anethum graveolens L.) from Bulgaria was analyzed by physicochemical methods, gas chromatography (GC), GC-mass spectrometry (MS) (achiral and chiral phases), and olfactometry, and its antimicrobial activity was tested by using different strains of microorganisms. More than 40 constituents of the essential dill oil, obtained from seeds stored for more than 35 years, could be identified as essential volatiles, responsible for the pleasant fresh (D-limonene) and spicy (D-carvone) odor of a high quality. As aroma impact compounds, D-carvone (50.1%) and D-limonene (44.1%) were found. Antimicrobial testings showed high activity of the essential A. graveolens oil against the mold Aspergillus niger and the yeasts Saccharomyces cerevisiae and Candida albicans.

  6. Eddy covariance measurements of carbon dioxide, latent and sensible energy fluxes above a meadow on a mountain slope

    PubMed Central

    Hammerle, Albin; Haslwanter, Alois; Schmitt, Michael; Bahn, Michael; Tappeiner, Ulrike; Cernusca, Alexander; Wohlfahrt, Georg

    2014-01-01

    Carbon dioxide, latent and sensible energy fluxes were measured by means of the eddy covariance method above a mountain meadow situated on a steep slope in the Stubai Valley/Austria, based on the hypothesis that, due to the low canopy height, measurements can be made in the shallow equilibrium layer where the wind field exhibits characteristics akin to level terrain. In order to test the validity of this hypothesis and to identify effects of complex terrain in the turbulence measurements, data were subjected to a rigorous testing procedure using a series of quality control measures established for surface layer flows. The resulting high-quality data set comprised 36 % of the original observations, the substantial reduction being mainly due to a change in surface roughness and associated fetch limitations in the wind sector dominating during nighttime and transition periods. The validity of the high-quality data set was further assessed by two independent tests: i) a comparison with the net ecosystem carbon dioxide exchange measured by means of ecosystem chambers and ii) the ability of the eddy covariance measurements to close the energy balance. The net ecosystem CO2 exchange measured by the eddy covariance method agreed reasonably with ecosystem chamber measurements. The assessment of the energy balance closure showed that there was no significant difference in the correspondence between the meadow on the slope and another one situated on flat ground at the bottom of the Stubai Valley, available energy being underestimated by 28 and 29 %, respectively. We thus conclude that, appropriate quality control provided, the eddy covariance measurements made above a mountain meadow on a steep slope are of similar quality as compared to flat terrain. PMID:24465032

  7. Challenges in the delivery of public HIV testing and counselling (HTC) in Douala, Cameroon: providers perspectives and implications on quality of HTC services.

    PubMed

    Ngangue, Patrice; Gagnon, Marie-Pierre; Bedard, Emmanuelle

    2017-04-08

    The Cameroon government has made HIV testing and counselling (HTC) a priority in its HIV/AIDS strategic plan. However, there is a dearth of literature on the perspectives of providers on the quality of HTC services. The aim of this study was to explore challenges in the provision of HTC services and their implications on quality of HTC services in Douala's district hospitals. Two primary data collection methods supported by the Donabedian's model of healthcare were used to explain the challenges in the provision of HTC services and their implications on quality of HTC services. This consisted of semi-structured individual interviews with 6 nurses and 16 lay counsellors and a non-participant observation of the physical environment for HTC by site. The study sites were the prevention and voluntary testing and counselling centre (PVTCC) of the six district hospitals of the city of Douala. The study reveals concerns about confidentiality and privacy during the counselling sessions due to inadequate and limited space. An absence of consent, even verbal, was reported in one PVTCC. There is no specific accredited training curriculum that leads to a formal registration as a PVTCC staff, and some lay counsellors work without training. Lay counsellors carry the burden of HIV counselling, but the majority of them work for many years without remuneration and recognition. Another quality challenge is the high workload in the district hospitals' lab, which leads to long waiting times for HIV test results, thus contributing to failure to return for results. The findings of this study highlighted some issues such as lack of adequate space and equipment for HIV testing and counselling that hinder the quality of HTC services and should challenge the health authorities of Cameroon on the need to reorganize HTC services and create a national HIV quality assurance program.

  8. Effect of home testing of international normalized ratio on clinical events.

    PubMed

    Matchar, David B; Jacobson, Alan; Dolor, Rowena; Edson, Robert; Uyeda, Lauren; Phibbs, Ciaran S; Vertrees, Julia E; Shih, Mei-Chiung; Holodniy, Mark; Lavori, Philip

    2010-10-21

    Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).

  9. Night vision imaging system design, integration and verification in spacecraft vacuum thermal test

    NASA Astrophysics Data System (ADS)

    Shang, Yonghong; Wang, Jing; Gong, Zhe; Li, Xiyuan; Pei, Yifei; Bai, Tingzhu; Zhen, Haijing

    2015-08-01

    The purposes of spacecraft vacuum thermal test are to characterize the thermal control systems of the spacecraft and its component in its cruise configuration and to allow for early retirement of risks associated with mission-specific and novel thermal designs. The orbit heat flux is simulating by infrared lamp, infrared cage or electric heater. As infrared cage and electric heater do not emit visible light, or infrared lamp just emits limited visible light test, ordinary camera could not operate due to low luminous density in test. Moreover, some special instruments such as satellite-borne infrared sensors are sensitive to visible light and it couldn't compensate light during test. For improving the ability of fine monitoring on spacecraft and exhibition of test progress in condition of ultra-low luminous density, night vision imaging system is designed and integrated by BISEE. System is consist of high-gain image intensifier ICCD camera, assistant luminance system, glare protect system, thermal control system and computer control system. The multi-frame accumulation target detect technology is adopted for high quality image recognition in captive test. Optical system, mechanical system and electrical system are designed and integrated highly adaptable to vacuum environment. Molybdenum/Polyimide thin film electrical heater controls the temperature of ICCD camera. The results of performance validation test shown that system could operate under vacuum thermal environment of 1.33×10-3Pa vacuum degree and 100K shroud temperature in the space environment simulator, and its working temperature is maintains at 5° during two-day test. The night vision imaging system could obtain video quality of 60lp/mm resolving power.

  10. Diagnostic accuracy of nucleic acid amplification tests (NAATs) in urine for genitourinary tuberculosis: a systematic review and meta-analysis.

    PubMed

    Altez-Fernandez, Carlos; Ortiz, Victor; Mirzazadeh, Majid; Zegarra, Luis; Seas, Carlos; Ugarte-Gil, Cesar

    2017-06-05

    Genitourinary tuberculosis is the third most common form of extrapulmonary tuberculosis. Diagnosis is difficult because of unspecific clinical manifestations and low accuracy of conventional tests. Unfortunately, the delayed diagnosis impacts the urinary tract severely. Nucleic acid amplification tests yield fast results, and among these, new technologies can also detect drug resistance. There is lack of consensus regarding the use of these tests in genitourinary tuberculosis; we therefore aimed to assess the accuracy of nucleic acid amplification tests in the diagnosis of genitourinary tuberculosis and to evaluate the heterogeneity between studies. We did a systematic review and meta-analysis of research articles comparing the accuracy of a reference standard and a nucleic acid amplification test for diagnosis of urinary tract tuberculosis. We searched Medline, EMBASE, Web of Science, LILACS, Cochrane Library, and Scopus for articles published between Jan 1, 1990, and Apr 14, 2016. Two investigators identified eligible articles and extracted data for individual study sites. We analyzed data in groups with the same index test. Then, we generated pooled summary estimates (95% CIs) for sensitivity and specificity by use of random-effects meta-analysis when studies were not heterogeneous. We identified eleven relevant studies from ten articles, giving information on PCR, LCR and Xpert MTB/RIF tests. All PCR studies were "in-house" tests, with different gene targets and had several quality concerns therefore we did not proceed with a pooled analysis. Only one study used LCR. Xpert studies were of good quality and not heterogeneous, pooled sensitivity was 0·87 (0·66-0·96) and specificity was 0·91 (0·84-0·95). PCR studies were highly heterogeneous. Among Xpert MTB/RIF studies, specificity was favorable with an acceptable confidence interval, however new studies can update meta-analysis and get more precise estimates. Further high-quality studies are urgently needed to improve diagnosis of genitourinary tuberculosis. PROSPERO CRD42016039020.

  11. Introduction of Syphilis Point-of-Care Tests, from Pilot Study to National Programme Implementation in Zambia: A Qualitative Study of Healthcare Workers' Perspectives on Testing, Training and Quality Assurance.

    PubMed

    Ansbro, Éimhín M; Gill, Michelle M; Reynolds, Joanna; Shelley, Katharine D; Strasser, Susan; Sripipatana, Tabitha; Tshaka Ncube, Alexander; Tembo Mumba, Grace; Terris-Prestholt, Fern; Peeling, Rosanna W; Mabey, David

    2015-01-01

    Syphilis affects 1.4 million pregnant women globally each year. Maternal syphilis causes congenital syphilis in over half of affected pregnancies, leading to early foetal loss, pregnancy complications, stillbirth and neonatal death. Syphilis is under-diagnosed in pregnant women. Point-of-care rapid syphilis tests (RST) allow for same-day treatment and address logistical barriers to testing encountered with standard Rapid Plasma Reagin testing. Recent literature emphasises successful introduction of new health technologies requires healthcare worker (HCW) acceptance, effective training, quality monitoring and robust health systems. Following a successful pilot, the Zambian Ministry of Health (MoH) adopted RST into policy, integrating them into prevention of mother-to-child transmission of HIV clinics in four underserved Zambian districts. We compare HCW experiences, including challenges encountered in scaling up from a highly supported NGO-led pilot to a large-scale MoH-led national programme. Questionnaires were administered through structured interviews of 16 HCWs in two pilot districts and 24 HCWs in two different rollout districts. Supplementary data were gathered via stakeholder interviews, clinic registers and supervisory visits. Using a conceptual framework adapted from health technology literature, we explored RST acceptance and usability. Quantitative data were analysed using descriptive statistics. Key themes in qualitative data were explored using template analysis. Overall, HCWs accepted RST as learnable, suitable, effective tools to improve antenatal services, which were usable in diverse clinical settings. Changes in training, supervision and quality monitoring models between pilot and rollout may have influenced rollout HCW acceptance and compromised testing quality. While quality monitoring was integrated into national policy and training, implementation was limited during rollout despite financial support and mentorship. We illustrate that new health technology pilot research can rapidly translate into policy change and scale-up. However, training, supervision and quality assurance models should be reviewed and strengthened as rollout of the Zambian RST programme continues.

  12. Introduction of Syphilis Point-of-Care Tests, from Pilot Study to National Programme Implementation in Zambia: A Qualitative Study of Healthcare Workers’ Perspectives on Testing, Training and Quality Assurance

    PubMed Central

    Ansbro, Éimhín M.; Gill, Michelle M.; Reynolds, Joanna; Shelley, Katharine D.; Strasser, Susan; Sripipatana, Tabitha; Ncube, Alexander Tshaka; Tembo Mumba, Grace; Terris-Prestholt, Fern; Peeling, Rosanna W.; Mabey, David

    2015-01-01

    Syphilis affects 1.4 million pregnant women globally each year. Maternal syphilis causes congenital syphilis in over half of affected pregnancies, leading to early foetal loss, pregnancy complications, stillbirth and neonatal death. Syphilis is under-diagnosed in pregnant women. Point-of-care rapid syphilis tests (RST) allow for same-day treatment and address logistical barriers to testing encountered with standard Rapid Plasma Reagin testing. Recent literature emphasises successful introduction of new health technologies requires healthcare worker (HCW) acceptance, effective training, quality monitoring and robust health systems. Following a successful pilot, the Zambian Ministry of Health (MoH) adopted RST into policy, integrating them into prevention of mother-to-child transmission of HIV clinics in four underserved Zambian districts. We compare HCW experiences, including challenges encountered in scaling up from a highly supported NGO-led pilot to a large-scale MoH-led national programme. Questionnaires were administered through structured interviews of 16 HCWs in two pilot districts and 24 HCWs in two different rollout districts. Supplementary data were gathered via stakeholder interviews, clinic registers and supervisory visits. Using a conceptual framework adapted from health technology literature, we explored RST acceptance and usability. Quantitative data were analysed using descriptive statistics. Key themes in qualitative data were explored using template analysis. Overall, HCWs accepted RST as learnable, suitable, effective tools to improve antenatal services, which were usable in diverse clinical settings. Changes in training, supervision and quality monitoring models between pilot and rollout may have influenced rollout HCW acceptance and compromised testing quality. While quality monitoring was integrated into national policy and training, implementation was limited during rollout despite financial support and mentorship. We illustrate that new health technology pilot research can rapidly translate into policy change and scale-up. However, training, supervision and quality assurance models should be reviewed and strengthened as rollout of the Zambian RST programme continues. PMID:26030741

  13. Framework for a National Testing and Evaluation Program Based Upon the National Stormwater Testing and Evaluation for Products and Practices (STEPP) Initiative (WERF Report INFR2R14)

    EPA Science Inventory

    Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective S...

  14. A test of 3 models of Kirtland's warbler habitat suitability

    Treesearch

    Mark D. Nelson; Richard R. Buech

    1996-01-01

    We tested 3 models of Kirtland's warbler (Dendroica kirtlandii) habitat suitability during a period when we believe there was a surplus of good quality breeding habitat. A jack pine canopy-cover model was superior to 2 jack pine stem-density models in predicting Kirtland's warbler habitat use and non-use. Estimated density of birds in high...

  15. NAPLAN, MySchool and Accountability: Teacher Perceptions of the Effects of Testing

    ERIC Educational Resources Information Center

    Thompson, Greg

    2013-01-01

    This paper explores Rizvi and Lingard's (2010) idea of the "local vernacular" of the global education policy trend of using high-stakes testing to increase accountability and transparency, and by extension quality, within schools and education systems in Australia. In the first part of the paper a brief context of the policy trajectory…

  16. The Impact of Model Parameterization and Estimation Methods on Tests of Measurement Invariance with Ordered Polytomous Data

    ERIC Educational Resources Information Center

    Koziol, Natalie A.; Bovaird, James A.

    2018-01-01

    Evaluations of measurement invariance provide essential construct validity evidence--a prerequisite for seeking meaning in psychological and educational research and ensuring fair testing procedures in high-stakes settings. However, the quality of such evidence is partly dependent on the validity of the resulting statistical conclusions. Type I or…

  17. High-level neutron coincidence counter maintenance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  18. Quality control of FWC during assembly and commissioning in SST-1 Tokamak

    NASA Astrophysics Data System (ADS)

    Patel, Hitesh; Santra, Prosenjit; Parekh, Tejas; Biswas, Prabal; Jayswal, Snehal; Chauhan, Pradeep; Paravastu, Yuvakiran; George, Siju; Semwal, Pratibha; Thankey, Prashant; Ramesh, Gattu; Prakash, Arun; Dhanani, Kalpesh; Raval, D. C.; Khan, Ziauddin; Pradhan, Subrata

    2017-04-01

    First Wall Components (FWC) of SST-1 tokamak, which are in the immediate vicinity of plasma, comprises of limiters, divertors, baffles, passive stabilizers designed to operate long duration (∼1000 s) discharges of elongated plasma. All FWC consist of copper alloy heat sink modules with SS cooling tubes brazed onto it, graphite tiles acting as armour material facing the plasma, and are mounted to the vacuum vessels with suitable Inconel support structures at inter-connected ring & port locations. The FWC are very recently assembled and commissioned successfully inside the vacuum vessel of SST-1 undergoing a rigorous quality control and checks at every stage of the assembly process. This paper will present the quality control aspects and checks of FWC from commencement of assembly procedure, namely material test reports, leak testing of high temperature baked components, assembled dimensional tolerances, leak testing of all welded joints, graphite tile tightening torques, electrical continuity and electrical isolation of passive stabilizers from vacuum vessel, baking and cooling hydraulic connections inside vacuum vessel.

  19. Water quality of a coastal lagoon (ES, Brazil): abiotic aspects, cytogenetic damage, and phytoplankton dynamics.

    PubMed

    Duarte, Ian Drumond; Silva, Nayara Heloisa Vieira Fraga; da Costa Souza, Iara; de Oliveira, Larissa Bassani; Rocha, Lívia Dorsch; Morozesk, Mariana; Bonomo, Marina Marques; de Almeida Pereira, Thaís; Dias, Mauro Cesar; de Oliveira Fernandes, Valéria; Matsumoto, Silvia Tamie

    2017-04-01

    Assessment of water resources requires interdisciplinary studies that include multiple ecosystem aspects. This study evaluated the water quality of Juara Lagoon (ES, Brazil) based on physical and chemical variables, cytogenetic responses in Allium cepa and phytoplankton dynamics. Three sampling sites were defined and water samples were collected during two sampling periods. Analyses such as determination of photic zone, conductivity, and concentrations of nutrients and metals were conducted as well as cytotoxic, mutagenic, and genotoxic potentials using A. cepa test. The main attributes of phytoplankton community, such as total richness, total density, density by class, dominance, and diversity, were also evaluated. Results have revealed that Juara Lagoon has signs of artificial eutrophication at two sampling sites due to high levels of total phosphorus and ammonia nitrogen. Cytotoxic, genotoxic, and mutagenic potentials were detected as well as high concentrations of Fe and Mn. Furthermore, 165 phytoplankton taxa were recorded, with highest richness in Chlorophyceae and Cyanophyceae classes. In addition, Cyanophyceae presented as the highest density class. A. cepa test and phytoplankton community evaluation indicated that the ecological quality of Juara Lagoon is compromised.

  20. VHF Ranging and Position Fixing Experiment Using ATS Satellites: Final Report on Phases 1 and 2, 25 November 1968 - 1 May 1971

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The testing program with the ATS-1 and ATS-3 spacecraft showed that geostationary satellites can provide superior communications and position surveillance for mobile craft. Inexpensive modifications to conventional mobile communications equipment aboard the craft can provide reliable, high quality voice and digital communications with distant ground stations and other vehicles, and automatic surveillance of the positions of all the craft by a ground facility. The tests also demonstrated the location and automatic readout of remote data collection platforms. Frequency modulation signals with the narrow audio and radio frequency bandwidths of terrestrial mobile radio communications were relayed through the VHF transponders of the geostationary satellites. The voice and digital communications were far superior in reliability and quality to long-distance mobile communications by other means. It was shown that one satellite can provide nearly uniform high quality performance over approximately one-third of the earth's surface. Position fixes by range measurement from the two satellites were accurate to approximately one nautical mile, except near the equator and the poles.

  1. Physician Satisfaction With Clinical Laboratory Services: A College of American Pathologists Q-Probes Study of 81 Institutions.

    PubMed

    McCall, Shannon J; Souers, Rhona J; Blond, Barbara; Massie, Larry

    2016-10-01

    -Assessment of customer satisfaction is a vital component of the laboratory quality improvement program. -To survey the level of physician satisfaction with hospital clinical laboratory services. -Participating institutions provided demographic information and survey results of physician satisfaction, with specific features of clinical laboratory services individually rated on a scale of 5 (excellent) to 1 (poor). -Eighty-one institutions submitted 2425 surveys. The median overall satisfaction score was 4.2 (10th percentile, 3.6; 90th percentile, 4.6). Of the 16 surveyed areas receiving the highest percentage of excellent/good ratings (combined scores of 4 and 5), quality of results was highest along with test menu adequacy, staff courtesy, and overall satisfaction. Of the 4 categories receiving the lowest percentage values of excellent/good ratings, 3 were related to turnaround time for inpatient "STAT" (tests performed immediately), outpatient STAT, and esoteric tests. The fourth was a new category presented in this survey: ease of electronic order entry. Here, 11.4% (241 of 2121) of physicians assigned below-average (2) or poor (1) scores. The 5 categories deemed most important to physicians included quality of results, turnaround times for inpatient STAT, routine, and outpatient STAT tests, and clinical report format. Overall satisfaction as measured by physician willingness to recommend their laboratory to another physician remains high at 94.5% (2160 of 2286 respondents). -There is a continued trend of high physician satisfaction and loyalty with clinical laboratory services. Physician dissatisfaction with ease of electronic order entry represents a new challenge. Test turnaround times are persistent areas of dissatisfaction, representing areas for improvement.

  2. PFLOTRAN Verification: Development of a Testing Suite to Ensure Software Quality

    NASA Astrophysics Data System (ADS)

    Hammond, G. E.; Frederick, J. M.

    2016-12-01

    In scientific computing, code verification ensures the reliability and numerical accuracy of a model simulation by comparing the simulation results to experimental data or known analytical solutions. The model is typically defined by a set of partial differential equations with initial and boundary conditions, and verification ensures whether the mathematical model is solved correctly by the software. Code verification is especially important if the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment [Oberkampf and Trucano (2007)]. Justified confidence in a particular computational tool requires clarity in the exercised physics and transparency in its verification process with proper documentation. We present a quality assurance (QA) testing suite developed by Sandia National Laboratories that performs code verification for PFLOTRAN, an open source, massively-parallel subsurface simulator. PFLOTRAN solves systems of generally nonlinear partial differential equations describing multiphase, multicomponent and multiscale reactive flow and transport processes in porous media. PFLOTRAN's QA test suite compares the numerical solutions of benchmark problems in heat and mass transport against known, closed-form, analytical solutions, including documentation of the exercised physical process models implemented in each PFLOTRAN benchmark simulation. The QA test suite development strives to follow the recommendations given by Oberkampf and Trucano (2007), which describes four essential elements in high-quality verification benchmark construction: (1) conceptual description, (2) mathematical description, (3) accuracy assessment, and (4) additional documentation and user information. Several QA tests within the suite will be presented, including details of the benchmark problems and their closed-form analytical solutions, implementation of benchmark problems in PFLOTRAN simulations, and the criteria used to assess PFLOTRAN's performance in the code verification procedure. References Oberkampf, W. L., and T. G. Trucano (2007), Verification and Validation Benchmarks, SAND2007-0853, 67 pgs., Sandia National Laboratories, Albuquerque, NM.

  3. Teacher Quality at the High-School Level: The Importance of Accounting for Tracks. Working Paper 17722. Revised

    ERIC Educational Resources Information Center

    Jackson, C. Kirabo

    2013-01-01

    Unlike in elementary school, high-school teacher effects may be confounded with both selection to tracks and unobserved track-level treatments. I document sizable confounding track effects, and show that traditional tests for the existence of teacher effects are likely biased. After accounting for these biases, high-school algebra and English…

  4. Implementation of and experiences with new automation

    PubMed Central

    Mahmud, Ifte; Kim, David

    2000-01-01

    In an environment where cost, timeliness, and quality drives the business, it is essential to look for answers in technology where these challenges can be met. In the Novartis Pharmaceutical Quality Assurance Department, automation and robotics have become just the tools to meet these challenges. Although automation is a relatively new concept in our department, we have fully embraced it within just a few years. As our company went through a merger, there was a significant reduction in the workforce within the Quality Assurance Department through voluntary and involuntary separations. However the workload remained constant or in some cases actually increased. So even with reduction in laboratory personnel, we were challenged internally and from the headquarters in Basle to improve productivity while maintaining integrity in quality testing. Benchmark studies indicated the Suffern site to be the choice manufacturing site above other facilities. This is attributed to the Suffern facility employees' commitment to reduce cycle time, improve efficiency, and maintain high level of regulatory compliance. One of the stronger contributing factors was automation technology in the laboratoriess, and this technology will continue to help the site's status in the future. The Automation Group was originally formed about 2 years ago to meet the demands of high quality assurance testing throughput needs and to bring our testing group up to standard with the industry. Automation began with only two people in the group and now we have three people who are the next generation automation scientists. Even with such a small staff,we have made great strides in laboratory automation as we have worked extensively with each piece of equipment brought in. The implementation process of each project was often difficult because the second generation automation group came from the laboratory and without much automation experience. However, with the involvement from the users at ‘get-go’, we were able to successfully bring in many automation technologies. Our first experience with automation was SFA/SDAS, and then Zymark TPWII followed by Zymark Multi-dose. The future of product testing lies in automation, and we shall continue to explore the possibilities of improving the testing methodologies so that the chemists will be less burdened with repetitive and mundane daily tasks and be more focused on bringing quality into our products. PMID:18924695

  5. Implementation of and experiences with new automation.

    PubMed

    Mahmud, I; Kim, D

    2000-01-01

    In an environment where cost, timeliness, and quality drives the business, it is essential to look for answers in technology where these challenges can be met. In the Novartis Pharmaceutical Quality Assurance Department, automation and robotics have become just the tools to meet these challenges. Although automation is a relatively new concept in our department, we have fully embraced it within just a few years. As our company went through a merger, there was a significant reduction in the workforce within the Quality Assurance Department through voluntary and involuntary separations. However the workload remained constant or in some cases actually increased. So even with reduction in laboratory personnel, we were challenged internally and from the headquarters in Basle to improve productivity while maintaining integrity in quality testing. Benchmark studies indicated the Suffern site to be the choice manufacturing site above other facilities. This is attributed to the Suffern facility employees' commitment to reduce cycle time, improve efficiency, and maintain high level of regulatory compliance. One of the stronger contributing factors was automation technology in the laboratoriess, and this technology will continue to help the site's status in the future. The Automation Group was originally formed about 2 years ago to meet the demands of high quality assurance testing throughput needs and to bring our testing group up to standard with the industry. Automation began with only two people in the group and now we have three people who are the next generation automation scientists. Even with such a small staff,we have made great strides in laboratory automation as we have worked extensively with each piece of equipment brought in. The implementation process of each project was often difficult because the second generation automation group came from the laboratory and without much automation experience. However, with the involvement from the users at 'get-go', we were able to successfully bring in many automation technologies. Our first experience with automation was SFA/SDAS, and then Zymark TPWII followed by Zymark Multi-dose. The future of product testing lies in automation, and we shall continue to explore the possibilities of improving the testing methodologies so that the chemists will be less burdened with repetitive and mundane daily tasks and be more focused on bringing quality into our products.

  6. Relationship of Pretreatment Rorschach Factors to Symptoms, Quality of Life, and Real-Life Functioning in a 3-Year Follow-Up of Traumatized Refugee Patients

    PubMed Central

    Opaas, Marianne; Hartmann, Ellen; Wentzel-Larsen, Tore; Varvin, Sverre

    2016-01-01

    ABSTRACT Response to mental health treatment varies highly among refugee patients. Research has not established which factors relate to differences in outcome. This study is a follow-up of Opaas and Hartmann's (2013) Rorschach Inkblot Method (RIM; Exner, 2003) pretreatment study of traumatized refugees, where 2 RIM principal components, Trauma Response and Reality Testing, were found descriptive of participants’ trauma-related personality functioning. This study's aims were to examine relationships of the RIM components with measures of anxiety, depression, posttraumatic stress, quality of life (QOL), employment, and exile language skills throughout 3 years. We found that impaired Reality Testing was related to more mental health symptoms and poorer QOL; furthermore, individuals with adequate Reality Testing improved in posttraumatic stress symptoms the first year and retained their improvement. Individuals with impaired Reality Testing deteriorated the first year and improved only slightly the next 2 years. The results of this study imply that traumatized refugee patients with impaired Reality Testing might need specific treatment approaches. Research follow-up periods should be long enough to detect changes. The reality testing impairment revealed by the RIM, mainly perceptual in quality, might not be easily detected by diagnostic interviews and self-report. PMID:26528822

  7. The reliability of physical examination tests for the clinical assessment of scapular dyskinesis in subjects with shoulder complaints: A systematic review.

    PubMed

    Lange, Toni; Struyf, Filip; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-07-01

    Systematic review. The aim of this systematic review was to summarize and evaluate intra- and interrater reliability research of physical examination tests used for the assessment of scapular dyskinesis. Scapular dyskinesis, defined as alteration of normal scapular kinematics, is described as a non-specific response to different shoulder pathologies. A systematic literature search was conducted in MEDLINE, EMBASE, AMED and PEDro until March 20th, 2015. Methodological quality was assessed with the Quality Appraisal of Reliability Studies (QAREL) by two independent reviewers. The search strategy revealed 3259 articles, of which 15 met the inclusion criteria. These studies evaluated the reliability of 41 test and test variations used for the assessment of scapular dyskinesis. This review identified a lack of high-quality studies evaluating intra- as well as interrater reliability of tests used for the assessment of scapular dyskinesis. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. The effect of manual correction of the scapula on shoulder symptoms was evaluated in only one study, which is striking, since symptom alteration tests are used in routine care to guide further treatment. Thus, there is a strong need for further research in this area. Diagnosis, level 3a. Copyright © 2016. Published by Elsevier Ltd.

  8. Results of the ESA study on psychological selection of astronaut applicants for Columbus missions I: Aptitude testing

    NASA Astrophysics Data System (ADS)

    Fassbender, Christoph; Goeters, Klaus-Martin

    European participation in the Space Station Freedom brought about new challenges for the psychological selection of astronaut candidates, particularly in respect to specific demands of long duration space flights. For this reason existing selection criteria and methods were reassessed. On these grounds a study was undertaken applying a unique composition of aptitude tests to a group of 97 ESA scientists and engineers who are highly comparable to the expected astronaut applicants with respect to age and education. The tests assessed operational aptitudes such as logical reasoning, memory function, perception, spatial orientation, attention, psychomotor function, and multiple task capacity. The study goals were: 1) Verification of psychometric qualities and applicability of tests in a normative group; 2) Search for culture-fair tests by which multi-national groups can be examined; 3) Identification of test methods which consider general and special operational demands of long duration space flights. Based on the empirical findings a test battery was arranged for use in the selection of ESA astronaut applicants. Results showed that 16 out of the 18 employed tests have good psychometric qualities and differentiate reliably in the special group of testees. The meta structure of the test battery as described by a factorial analysis is presented. Applicability of tests was generally high. Tests were culture-fair, however, a relation between English language skills and test results was identified. Since most item material was language-free, this was explained with the importance of English language skills for the understanding of test instructions. Solutions to this effect are suggested.

  9. A survey of Canadian websites providing information about female urinary incontinence.

    PubMed

    Farrell, Karen D; Robinson, Lynne M; Baydock, Sandra A; Farrell, Scott A; Irving, Linda E; O'Connell, Colleen M

    2006-08-01

    Urinary incontinence (UI) is a prevalent health issue that has significant detrimental effects on quality of life. The Internet offers a unique vehicle for incontinent women to access information that could facilitate conservative self-help therapy. An evaluation of Canadian websites offering female UI information was conducted to determine their quality and readability. We evaluated websites using published general quality criteria for health sites and a quality assessment tool compiled by the authors for specific UI information derived from published, peer-reviewed clinical practice guidelines. Three health care professionals reviewed sites for quality, Canadian content, and interactivity. The readability of health information was also evaluated. Fifty-six Canadian sites (18 professional, 22 organizational, 16 commercial) were evaluated. Significant agreement was found among the raters' evaluations on all measures. For all sites, the mean scores were general quality, 9/14; specific UI quality, 30/122; reading ease, 37/100; grade level, 10.9. The median score for Canadian content was high, but for interactivity it was low. The only significant difference between site types was for general quality (F [2,165]=3.38, P=0.036). Post hoc Tukey's tests showed a significant difference between organizational and commercial sites, with organizational sites having higher general quality. Canadian websites providing female UI information have moderately high general quality, low specific UI information quality, minimal interactivity, and more than minimal Canadian content. The reading level of most sites is too high for average consumers. A webliography of the best sites has been developed to guide patients.

  10. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    PubMed

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ± 1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

  11. Assessment of the quality of anti-tuberculosis medicines in Almaty, Kazakhstan, 2014

    PubMed Central

    Nabirova, D.; Schmid, G.; Yusupova, R.; Kantarbayeva, M.; Ismailov, S. I.; Moffett, D.; Jähnke, R. W. O.; Nuorti, J. P.

    2017-01-01

    SUMMARY SETTING In 2009, the World Health Organization (WHO) conducted a survey of the quality of four anti-tuberculosis drugs in the former Soviet Union countries. Kazakhstan had the highest proportion of substandard drugs. OBJECTIVE To assess the quality of anti-tuberculosis drugs used in Kazakhstan in 2014. DESIGN Fourteen anti-tuberculosis drugs from the Almaty Interdistrict TB Dispensary were randomly selected and screened for quality using Global Pharma Health Fund Minilab™ testing. First, the product and packaging were physically inspected to determine whether tablets/capsules were intact (i.e., whether they contained the full amount of the drug, and whether the packaging was genuine). Second, the tablets/capsules were dissolved in water to test whether they could be adequately absorbed by the body. Finally, semi-quantitive analyses were undertaken using thin-layer chromatography to verify the presence and concentration of the active pharmaceutical ingredient and to detect impurities. RESULTS We discovered no counterfeit medicines. However, 163 (19%) of the 854 anti-tuberculosis drugs sampled failed at least one of the three tests. These samples were found among 24/50 (48%) batches of 14 anti-tuberculosis drugs. CONCLUSION Our study identified a high proportion of poor-quality first- and second-line anti-tuberculosis drugs. Use of these medicines may lead to treatment failure and the development of drug resistance. Confirmatory testing should be performed to determine if they should be removed from the market. PMID:28911362

  12. Cost-effectiveness of lobectomy versus genetic testing (Afirma®) for indeterminate thyroid nodules: Considering the costs of surveillance.

    PubMed

    Balentine, Courtney J; Vanness, David J; Schneider, David F

    2018-01-01

    We evaluated whether diagnostic thyroidectomy for indeterminate thyroid nodules would be more cost-effective than genetic testing after including the costs of long-term surveillance. We used a Markov decision model to estimate the cost-effectiveness of thyroid lobectomy versus genetic testing (Afirma®) for evaluation of indeterminate (Bethesda 3-4) thyroid nodules. The base case was a 40-year-old woman with a 1-cm indeterminate nodule. Probabilities and estimates of utilities were obtained from the literature. Cost estimates were based on Medicare reimbursements with a 3% discount rate for costs and quality-adjusted life-years. During a 5-year period after the diagnosis of indeterminate thyroid nodules, lobectomy was less costly and more effective than Afirma® (lobectomy: $6,100; 4.50 quality-adjusted life- years vs Afirma®: $9,400; 4.47 quality-adjusted life-years). Only in 253 of 10,000 simulations (2.5%) did Afirma® show a net benefit at a cost-effectiveness threshold of $100,000 per quality- adjusted life-years. There was only a 0.3% probability of Afirma® being cost saving and a 14.9% probability of improving quality-adjusted life-years. Our base case estimate suggests that diagnostic lobectomy dominates genetic testing as a strategy for ruling out malignancy of indeterminate thyroid nodules. These results, however, were highly sensitive to estimates of utilities after lobectomy and living under surveillance after Afirma®. Published by Elsevier Inc.

  13. Manufacture and evaluation of Li/BCX DD cells

    NASA Technical Reports Server (NTRS)

    Meyer, S.; Takeuchi, E.

    1990-01-01

    This project is divided into four main tasks: cell manufacture, acceptance, and lot certification of cells, performance testing of cells, and abuse testing of cells. Lithium/bromine chloride in thionyl chloride (Li/BCX) 149 DD cells (PN 3B2085-XA) were built according to the provisions of Electrochem Industries Quality Plan 17096. Acceptance and lot certification testing was performed according to NASA JSC Document EP5-83-025, Revision B. Acceptance testing included open circuit and load voltage check, visual examination, size and weight measurements, and high temperature exposure. Lot certification tests were performed for capacity performance and for performance under conditions of thermal and electrical abuse. These tests included 149 C exposure, capacity discharge, fuse check, high temperature exposure, high rate discharge, short circuit, vibration, and overdischarge testing. A quantity of 200 cells was delivered to Johnson Space Center for life test evaluation. A parametric evaluation of the capacity discharge of Li/BCX DD cells was performed over a variety of temperatures and discharge rates. This testing served to map the performance capability of the cell. Tests were also performed over a variety of electrical and thermal abuse conditions. Abuse tests included short circuit, charging, overdischarge, high temperature exposure, shock, and vibration.

  14. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  15. 7 CFR 58.335 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  16. High power cable with internal water cooling 400 kV

    NASA Astrophysics Data System (ADS)

    Rasquin, W.; Harjes, B.

    1982-08-01

    Due to the concentration of electricity production in large power plants, the need of higher power transmissions, and the protection of environment, developement of a 400 kV water cooled cable in the power range of 1 to 5 GVA was undertaken. The fabrication and testing of equipment, engineering of cable components, fabrication of a test cable, development of cable terminal laboratory, testing of test cable, field testing of test cable, fabrication of industrial cable laboratory, testing of industrial cable, field testing of industrial cable, and system analysis for optimization were prepared. The field testing was impossible to realize. However, it is proved that a cable consisting of an internal stainless steel water cooled tube, covered by stranded copper profiles, insulated with heavy high quality paper, and protected by an aluminum cover can be produced, withstand tests accordingly to IEC/VDE recommendations, and is able to fulfill all exploitation conditions.

  17. The Significance of Breakdown Voltages for Quality Assurance of Low-Voltage BME Ceramic Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2014-01-01

    Application of thin dielectric, base metal electrode (BME) ceramic capacitors for high-reliability applications requires development of testing procedures that can assure high quality and reliability of the parts. In this work, distributions of breakdown voltages (VBR) in variety of low-voltage BME multilayer ceramic capacitors (MLCCs) have been measured and analyzed. It has been shown that analysis of the distributions can indicate the proportion of defective parts in the lot and significance of the defects. Variations of the distributions after solder dip testing allow for an assessment of the robustness of capacitors to soldering-related stresses. The drawbacks of the existing screening and qualification methods to reveal defects in high-value, low-voltage MLCCs and the importance of VBR measurements are discussed. Analysis has shown that due to a larger concentration of oxygen vacancies, defect-related degradation of the insulation resistance (IR) and failures are more likely in BME compared to the precious metal electrode (PME) capacitors.

  18. HDBStat!: a platform-independent software suite for statistical analysis of high dimensional biology data.

    PubMed

    Trivedi, Prinal; Edwards, Jode W; Wang, Jelai; Gadbury, Gary L; Srinivasasainagendra, Vinodh; Zakharkin, Stanislav O; Kim, Kyoungmi; Mehta, Tapan; Brand, Jacob P L; Patki, Amit; Page, Grier P; Allison, David B

    2005-04-06

    Many efforts in microarray data analysis are focused on providing tools and methods for the qualitative analysis of microarray data. HDBStat! (High-Dimensional Biology-Statistics) is a software package designed for analysis of high dimensional biology data such as microarray data. It was initially developed for the analysis of microarray gene expression data, but it can also be used for some applications in proteomics and other aspects of genomics. HDBStat! provides statisticians and biologists a flexible and easy-to-use interface to analyze complex microarray data using a variety of methods for data preprocessing, quality control analysis and hypothesis testing. Results generated from data preprocessing methods, quality control analysis and hypothesis testing methods are output in the form of Excel CSV tables, graphs and an Html report summarizing data analysis. HDBStat! is a platform-independent software that is freely available to academic institutions and non-profit organizations. It can be downloaded from our website http://www.soph.uab.edu/ssg_content.asp?id=1164.

  19. High Power Laser Welding. [of stainless steel and titanium alloy structures

    NASA Technical Reports Server (NTRS)

    Banas, C. M.

    1972-01-01

    A review of recent developments in high power, carbon dixoide laser welding is presented. Deep penetration welding in stainless steel to 0.5-in. thick, high speed welding in thin gage rimmed steel and gas shielded welding in Ti-6Al-4V alloy are described. The effects of laser power, power density, focusing optics, gas-shielding techniques, material properties and weld speed on weld quality and penetration are discussed. It is shown that laser welding performance in thin materials is comparable to that of electron beams. It is further shown that high quality welds, as evidenced by NDT, mechanical and metal-lographic tests, can be achieved. The potential of the laser for industrial welding applications is indicated.

  20. Noise-immune multisensor transduction of speech

    NASA Astrophysics Data System (ADS)

    Viswanathan, Vishu R.; Henry, Claudia M.; Derr, Alan G.; Roucos, Salim; Schwartz, Richard M.

    1986-08-01

    Two types of configurations of multiple sensors were developed, tested and evaluated in speech recognition application for robust performance in high levels of acoustic background noise: One type combines the individual sensor signals to provide a single speech signal input, and the other provides several parallel inputs. For single-input systems, several configurations of multiple sensors were developed and tested. Results from formal speech intelligibility and quality tests in simulated fighter aircraft cockpit noise show that each of the two-sensor configurations tested outperforms the constituent individual sensors in high noise. Also presented are results comparing the performance of two-sensor configurations and individual sensors in speaker-dependent, isolated-word speech recognition tests performed using a commercial recognizer (Verbex 4000) in simulated fighter aircraft cockpit noise.

Top