Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan
2018-04-25
This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License
ECAT: A New Computerized Tomographic Imaging System for Position-Emitting Radiopharmaceuticals
DOE R&D Accomplishments Database
Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Kuhl, D. E.
1977-01-01
The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems.
High-resolution radiography by means of a hodoscope
De Volpi, Alexander
1978-01-01
The fast neutron hodoscope, a device that produces neutron radiographs with coarse space resolution in a short time, is modified to produce neutron or gamma radiographs of relatively thick samples and with high space resolution. The modification comprises motorizing a neutron and gamma collimator to permit a controlled scanning pattern, simultaneous collection of data in a number of hodoscope channels over a period of time, and computerized image reconstruction of the data thus gathered.
Mid-Frequency Sonar Interactions with Beaked Whales
2011-06-30
Beaked Whale, was not completed. However, several other goals were achieved, including synthesis of a morphometric model of a beaked whale. This and work...induced acoustic fields inside beaked whales and other marine mammals. Another high-level goal was to acquire new high-resolution morphometric and...range 1-10 kHz; collecting high-resolution morphometric data through computerized tomography (CT) scans on marine mammal specimens, and constructing
High resolution collimator system for X-ray detector
Eberhard, Jeffrey W.; Cain, Dallas E.
1987-01-01
High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.
Clinical applications of computerized thermography
NASA Technical Reports Server (NTRS)
Anbar, Michael
1988-01-01
Computerized or digital, thermography is a rapidly growing diagnostic imaging modality. It has superseded contact thermography and analog imaging thermography which do not allow effective quantization. Medical applications of digital thermography can be classified in two groups: static and dynamic imaging. They can also be classified into macro thermography (resolution greater than 1 mm) and micro thermography (resolution less than 100 microns). Both modalities allow a thermal resolution of 0.1 C. The diagnostic power of images produced by any of these modalities can be augmented by the use of digital image enhancement and image recognition procedures. Computerized thermography has been applied in neurology, cardiovascular and plastic surgery, rehabilitation and sports medicine, psychiatry, dermatology and ophthalmology. Examples of these applications are shown and their scope and limitations are discussed.
High resolution, MRI-based, segmented, computerized head phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zubal, I.G.; Harrell, C.R.; Smith, E.O.
1999-01-01
The authors have created a high-resolution software phantom of the human brain which is applicable to voxel-based radiation transport calculations yielding nuclear medicine simulated images and/or internal dose estimates. A software head phantom was created from 124 transverse MRI images of a healthy normal individual. The transverse T2 slices, recorded in a 256x256 matrix from a GE Signa 2 scanner, have isotropic voxel dimensions of 1.5 mm and were manually segmented by the clinical staff. Each voxel of the phantom contains one of 62 index numbers designating anatomical, neurological, and taxonomical structures. The result is stored as a 256x256x128 bytemore » array. Internal volumes compare favorably to those described in the ICRP Reference Man. The computerized array represents a high resolution model of a typical human brain and serves as a voxel-based anthropomorphic head phantom suitable for computer-based modeling and simulation calculations. It offers an improved realism over previous mathematically described software brain phantoms, and creates a reference standard for comparing results of newly emerging voxel-based computations. Such voxel-based computations lead the way to developing diagnostic and dosimetry calculations which can utilize patient-specific diagnostic images. However, such individualized approaches lack fast, automatic segmentation schemes for routine use; therefore, the high resolution, typical head geometry gives the most realistic patient model currently available.« less
Impact of Soldier Helmet Configuration on Survivability
2011-03-01
helmet cannot sit too low, which is evident when the helmet covers the eyebrows and the helmet interferes with eyewear . The helmet should remain in...agencies, academia, and private industry have also aided in model development. ORCA is a high-resolution computerized personnel casualty model that can
Cost-Effective and High-Resolution Subsurface Characterization Using Hydraulic Tomography
2017-08-28
implementation and compare costs associated with HT and conventional methods. TECHNOLOGY DESCRIPTION The HT concept is analogous to the Computerized...develop guidance for HT field implementation and compare costs associated with HT and conventional methods. 15. SUBJECT TERMS Subsurface...3 2.1 TECHNOLOGY DESCRIPTION
Scanning instrumentation for measuring magnetic field trapping in high Tc superconductors
NASA Technical Reports Server (NTRS)
Sisk, R. C.; Helton, A. J.
1993-01-01
Computerized scanning instrumentation measures and displays trapped magnetic fields across the surface of high Tc superconductors at 77 K. Data are acquired in the form of a raster scan image utilizing stepping motor stages for positioning and a cryogenic Hall probe for magnetic field readout. Flat areas up to 45 mm in diameter are scanned with 0.5-mm resolution and displayed as false color images.
Mid-Frequency Sonar Interactions With Beaked Whales
2009-09-30
to acquire new high-resolution morphometric and physical-property data on beaked whales for use in the model. It is hoped that the availability of such... morphometric and physical-property data on beaked whales for use in the model. It is hoped that the availability of such a system, together with high-quality... morphometric data through computerized tomography (CT) scans on marine mammal carcasses, and constructing finite-element models of the anatomy
Genesis of Atlantic Lows Experiment NASA Electra Boundary Layer Flights Data Report
NASA Technical Reports Server (NTRS)
Palm, Stephen P.; Melfi, S. H.; Boers, Reinout
1988-01-01
The objective of this research was to obtain high resolution measurements of the height of the Marine Atmospheric Boundary Layer (MABL) during cold air outbreaks using an Airborne Lidar System. The research was coordinated with other investigators participating in the Genesis of Atlantic Lows Experiment (GALE). An objective computerized scheme was developed to obtain the Boundary Layer Height from the Lidar Data. The algorithm was used on each of the four flight days producing a high resolution data set of the MABL height over the GALE experiment area. Plots of the retrieved MABL height as well as tabular data summaries are presented.
RAYSAW: a log sawing simulator for 3D laser-scanned hardwood logs
R. Edward Thomas
2013-01-01
Laser scanning of hardwood logs provides detailed high-resolution imagery of log surfaces. Characteristics such as sweep, taper, and crook, as well as most surface defects, are visible to the eye in the scan data. In addition, models have been developed that predict interior knot size and position based on external defect information. Computerized processing of...
Preliminary results of a computerized Placido disk surgical corneal topographer
NASA Astrophysics Data System (ADS)
Carvalho, Luis A.; Tonissi, S. A.; Castro, Jarbas C.
1999-06-01
We have developed a novel instrument for computerized corneal topography during surgery. The instrument measures a region of approximately 7 mm in diameter, providing the surgeon with precise values of power and astigmatism. The system is based on a Placido Disc projecting system, which is attached to the objective lens of the surgical microscope. The Placido Disc pattern is reflected by a 50% beam splitter attached to the body of the microscope. At the beam splitter we installed our home-made adaptor and a CCD monochromatic high resolution camera. A high quality frame grabber is installed on a PC and images are digitized at a 480x640 resolution. Algorithms based on image processing techniques were implemented for edge detection of pattern. Calibrating curves based on 4 spherical surfaces were generated and approximately 3600 points were calculated for each exam. Preliminary measurements on 10 healthy corneas were compared with the measurements made on an EyeSys Corneal Topographer. Mean deviation was 0.05 for radius of curvature, 0.24 D for power and 5 degrees for cylinder. This system, with some improvements, may be successfully used to diminish high post surgical astigmatisms in surgeries such as cataract and corneal transplant. This system could also be used to gather preoperative data in corneal topography assisted LASIK.
Sawall, Mathias; Kubis, Christoph; Börner, Armin; Selent, Detlef; Neymeyr, Klaus
2015-09-03
Modern computerized spectroscopic instrumentation can result in high volumes of spectroscopic data. Such accurate measurements rise special computational challenges for multivariate curve resolution techniques since pure component factorizations are often solved via constrained minimization problems. The computational costs for these calculations rapidly grow with an increased time or frequency resolution of the spectral measurements. The key idea of this paper is to define for the given high-dimensional spectroscopic data a sequence of coarsened subproblems with reduced resolutions. The multiresolution algorithm first computes a pure component factorization for the coarsest problem with the lowest resolution. Then the factorization results are used as initial values for the next problem with a higher resolution. Good initial values result in a fast solution on the next refined level. This procedure is repeated and finally a factorization is determined for the highest level of resolution. The described multiresolution approach allows a considerable convergence acceleration. The computational procedure is analyzed and is tested for experimental spectroscopic data from the rhodium-catalyzed hydroformylation together with various soft and hard models. Copyright © 2015 Elsevier B.V. All rights reserved.
Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David
2012-04-01
Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.
High School Concussions in the 2008–2009 Academic Year
Meehan, William P.; d’Hemecourt, Pierre; Comstock, R. Dawn
2011-01-01
Background An estimated 136 000 concussions occur per academic year in high schools alone. The effects of repetitive concussions and the potential for catastrophic injury have made concussion an injury of significant concern for young athletes. Purpose The objective of this study was to describe the mechanism of injury, symptoms, and management of sport-related concussions using the High School Reporting Information Online (HS RIO) surveillance system. Study Design Descriptive epidemiology study. Methods All concussions recorded by HS RIO during the 2008–2009 academic year were included. Analyses were performed using SPSS software. Chi-square analysis was performed for all categorical variables. Statistical significance was considered for P < .05. Results A total of 544 concussions were recorded. The most common mechanism (76.2%) was contact with another player, usually a head-to-head collision (52.7%). Headache was experienced in 93.4%; 4.6% lost consciousness. Most (83.4%) had resolution of their symptoms within 1 week. Symptoms lasted longer than 1 month in 1.5%. Computerized neuropsychological testing was used in 25.7% of concussions. When neuropsychological testing was used, athletes were less likely to return to play within 1 week than those for whom it was not used (13.6% vs 32.9%; P < .01). Athletes who had neuropsychological testing appeared less likely to return to play on the same day (0.8% vs 4.2%; P = .056). A greater proportion of injured, nonfootball athletes had computerized neuropsychological testing than injured football players (23% vs 32%; P = .02) Conclusion When computerized neuropsychological testing is used, high school athletes are less likely to be returned to play within 1 week of their injury. Concussed football players are less likely to have computerized neuropsychological testing than those participating in other sports. Loss of consciousness is relatively uncommon among high school athletes who sustain a sport-related concussion. The most common mechanism is contact with another player. Some athletes (1.5%) report symptoms lasting longer than 1 month. PMID:20716683
NASA Technical Reports Server (NTRS)
Browning, R.
1986-01-01
A custom scanning Auger electron microscope (SAM) capable of introducing a 3-5 keV electron beam of several nA into a 30 nm diameter sample area was fitted with a sample introduction system and was fully computerized to be used for materials science research. The method of multispectral Auger imaging was devised and implemented. The instrument was applied to various problems in materials science, including the study of the fiber/matrix interface in a SiC reinforced titanium alloy, the study of SiC whiskers in Al alloy 2124 (in cooperation with NASA-Langley), the study of NiCrAl superalloys (in collaboration with NASA-Lewis), the study of zircalloy specimens (in collaboration with Stanford University), and the microstructure of sintered SiC specimens (in collaboration with NASA-Lewis). The report contains a number of manuscripts submitted for publication on these subjects.
Di Vincenzo, Fabio; Carbone, Iacopo; Ottini, Laura; Profico, Antonio; Ricci, Francesca; Tafuri, Mary Anne; Fornaciari, Gino; Manzi, Giorgio
2015-01-01
The Middle Pastoral human remains from Wadi Takarkori in the Libyan Acacus mountains (Fezzan) are exceptionally preserved partial mummies ranging between 6100 and 5000 uncal years BP; this small sample represents the most ancient of its kind ever found. In this report, we present a survey of the skeletal anatomy of these mummifed corpses, based on high resolution CT-scan data, including a preliminary phenetic interpretation of their cranial morphology.
A close-range photogrammetric technique for mapping neotectonic features in trenches
Fairer, G.M.; Whitney, J.W.; Coe, J.A.
1989-01-01
Close-range photogrammetric techniques and newly available computerized plotting equipment were used to map exploratory trench walls that expose Quaternary faults in the vicinity of Yucca Mountain, Nevada. Small-scale structural, lithologic, and stratigraphic features can be rapidly mapped by the photogrammetric method. This method is more accurate and significantly more rapid than conventional trench-mapping methods, and the analytical plotter is capable of producing cartographic definition of high resolution when detailed trench maps are necessary. -from Authors
Tourtellotte, W G; Lawrence, D T; Getting, P A; Van Hoesen, G W
1989-07-01
This report describes a computerized microscope charting system based on the IBM personal computer or compatible. Stepping motors are used to control the movement of the microscope stage and to encode its position by hand manipulation of a joystick. Tissue section contours and the location of cells labeled with various compounds are stored by the computer, plotted at any magnification and manipulated into composites created from several charted sections. The system has many advantages: (1) it is based on an industry standardized computer that is affordable and familiar; (2) compact and commercially available stepping motor microprocessors control the stage movement. These controllers increase reliability, simplify implementation, and increase efficiency by relieving the computer of time consuming control tasks; (3) the system has an interactive graphics interface allowing the operator to view the image during data collection. Regions of the graphics display can be enlarged during the charting process to provide higher resolution and increased accuracy; (4) finally, the digitized data are stored at 0.5 micron resolution and can be routed directly to a multi-pen plotter or exported to a computer-aided design (CAD) program to generate a publication-quality montage composed of several computerized chartings. The system provides a useful tool for the acquisition and qualitative analysis of data representing stained cells or chemical markers in tissue. The modular design, together with data storage at high resolution, allows for potential analytical enhancements involving planimetric, stereologic and 3-D serial section reconstruction.
Bathla, Meeta; Doshi, Hiren; Kansara, Atul
2018-03-01
Role of high resolution computerized tomography (HRCT) of temporal bone is established in cases of atticoantral chronic suppurative otitis media (CSOM) with intracranial complications. Routine use of HRCT in management of patients of atticoantral CSOM without intracranial complications has been an issue of debate. The aim of this study was to evaluate the routine use of HRCT of temporal bone in such cases. This study was a prospective study done at LG hospital, AMC MET Medical College, Ahmedabad to evaluate and compare the temporal bone findings in HRCT and intraoperative findings in 100 patients with atticoantral CSOM. All patients underwent HRCT screening followed by surgical exploration of middle ear cleft. In extent of disease HRCT showed very high sensitivity and specificity for epitympanum (100, 94%) and mesotympanum (98, 98%) areas. It gave valuable information of disease extent in hidden areas like sinus tympani and facial recess of mesotympanum. HRCT satisfactorily delineated malleus and incus erosion but had 75% sensitivity for detecting erosion of stapes suprastructure, though specificity was of 97%. For bony anatomical landmarks HRCT showed very high sensitivity and specificity for detecting erosion of lateral semicircular canal, tegmen tympani and sinus plate. Detection of facial canal erosion on HRCT had moderate sensitivity of 75%. We concluded that routine use of HRCT is justified as a reliable preoperative tool in patients with atticoantral CSOM without intracranial complications and it helps to plan type of surgical intervention. HRCT has limited role to distinguish between granulations and cholesteatoma and also to delineate stapes supra structure and facial nerve canal.
Babu, Kalpana; Shukla, Sai Bhakti; Philips, Mariamma
2017-04-01
To review the role of high resolution chest computed tomography (HRCT) in ocular sarcoidosis in a high TB endemic population. This was a retrospective study. Out of 140 cases, 54 had ocular sarcoidosis, while 86 cases had ocular tuberculosis. Abnormal HRCT findings was noted in 52 cases (96.3%) of ocular sarcoidosis compared with 55 cases (64.7%) of ocular tuberculosis (p = 0.001). Mediastinal lymphadenopathy was the most common finding in both groups (p = 0.544). Hilar lymphadenopathy and fissural nodules were significantly seen in ocular sarcoidosis (p = 0.001). Necrosis was seen in three cases of ocular sarcoidosis. In nearly half of the cases, it was not possible to differentiate between sarcoidosis and tuberculosis on HRCT. HRCT is a useful diagnostic tool in ocular sarcoidosis. Bilateral hilar lymphadenopathy and fissural nodules are significant findings in ocular sarcoidosis. A confident diagnosis of ocular sarcoidosis is made by the amalgamation of results of clinical, radiologic, and other laboratory investigations.
Potential Applications of Manual Games,
1984-02-01
34 just because some electronic equipment is used to keep track of logistics, combat results, and force status. Even a highly computerized game like...D-A152 541 POTENTIAL APPLICATIONS OF MANUAL GAMES (U) RAND CORP ii SANTA MONICA CA T A BROW~N FEB 84 RAND/P-6957 UNCLASI7FIED F/G 12/2 N El..I 111 1...128 112.5 111 m; * _ 1.8 I1111 ’I’ll MICROCOPY RESOLUTION TEST CHART NATI NAl fii~ t1 RI 1A L4k, I POTENTIAL APPLICATIONS OF MANUJAL GAMES Lfl N Lfl
Wind Energy Resource Atlas of the Dominican Republic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, D.; Schwartz, M.; George, R.
2001-10-01
The Wind Energy Resource Atlas of the Dominican Republic identifies the wind characteristics and the distribution of the wind resource in this country. This major project is the first of its kind undertaken for the Dominican Republic. The information contained in the atlas is necessary to facilitate the use of wind energy technologies, both for utility-scale power generation and off-grid wind energy applications. A computerized wind mapping system developed by NREL generated detailed wind resource maps for the entire country. This technique uses Geographic Information Systems (GIS) to produce high-resolution (1-square kilometer) annual average wind resource maps.
Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.
Pelletier, J L; Milan, C; Touzery, C; Coitoux, P; Gailliard, P; Budinger, T F
1980-01-01
Emission computerized axial tomography is achievable in any nuclear medicine department from multiple gamma camera views. Data are collected by rotating the patient in front of the camera. A simple fast algorithm is implemented, known as the convolution technique: first the projection data are Fourier transformed and then an original filter designed for optimizing resolution and noise suppression is applied; finally the inverse transform of the latter operation is back-projected. This program, which can also take into account the attenuation for single photon events, was executed with good results on phantoms and patients. We think that it can be easily implemented for specific diagnostic problems.
Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hullar, Ted; Anastasio, Cort, E-mail: canastasio@ucdavis.edu; Paige, David F.
2014-04-15
High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °Cmore » ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.« less
Kirkpatrick, Naomi C; Blacker, Hayley P; Woods, Wayne G; Gasser, Robin B; Noormohammadi, Amir H
2009-02-01
Coccidiosis is a significant disease of poultry caused by different species of Eimeria. Differentiation of Eimeria species is important for the quality control of the live attenuated Eimeria vaccines derived from monospecific lines of Eimeria spp. In this study, high-resolution melting (HRM) curve analysis of the amplicons generated from the second internal transcribed spacer of nuclear ribosomal DNA (ITS-2) was used to distinguish between seven pathogenic Eimeria species of chickens, and the results were compared with those obtained from the previously described technique, capillary electrophoresis. Using a series of known monospecific lines of Eimeria species, HRM curve analysis was shown to distinguish between Eimeria acervulina, Eimeria brunetti, Eimeria maxima, Eimeria mitis, Eimeria necatrix, Eimeria praecox and Eimeria tenella. Computerized analysis of the HRM curves and capillary electrophoresis profiles could detect the dominant species in several specimens containing different ratios of E. necatrix and E. maxima and of E. tenella and E. acervulina. The HRM curve analysis identified all of the mixtures as "variation" to the reference species, and also identified the minor species in some mixtures. Computerized HRM curve analysis also detected impurities in 21 possible different combinations of the seven Eimeria species. The PCR-based HRM curve analysis of the ITS-2 provides a powerful tool for the detection and identification of pure Eimeria species. The HRM curve analysis could also be used as a rapid tool in the quality assurance of Eimeria vaccine production to confirm the purity of the monospecific cell lines. The HRM curve analysis is rapid and reliable and can be performed in a single test tube in less than 3 h.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atari, N.A.; Svensson, G.K.
1986-05-01
A high-resolution digital dosimetric system has been developed for the spatial characterization of radiation fields. The system comprises the following: 0.5-mm-thick, 25-mm-diam CaF/sub 2/:Dy thermoluminescent crystal; intensified charge coupled device video camera; video cassette recorder; and a computerized image processing subsystem. The optically flat single crystal is used as a radiation imaging device and the subsequent thermally stimulated phosphorescence is viewed by the intensified camera for further processing and analysis. Parameters governing the performance characteristics of the system were measured. A spatial resolution limit of 31 +- 2 ..mu..m (1sigma) corresponding to 16 +- 1 line pair/mm measured at themore » 4% level of the modulation transfer function has been achieved. The full width at half maximum of the line spread function measured independently by the slit method or derived from the edge response function was found to be 69 +- 4 ..mu..m (1sigma). The high resolving power, speed of readout, good precision, wide dynamic range, and the large image storage capacity make the system suitable for the digital mapping of the relative distribution of absorbed doses for various small radiation fields and the edges of larger fields.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atari, N.A.; Svensson, G.K.
1986-05-01
A high-resolution digital dosimetric system has been developed for the spatial characterization of radiation fields. The system comprises the following: 0.5-mm-thick, 25-mm-diam CaF2:Dy thermoluminescent crystal; intensified charge coupled device video camera; video cassette recorder; and a computerized image processing subsystem. The optically flat single crystal is used as a radiation imaging device and the subsequent thermally stimulated phosphorescence is viewed by the intensified camera for further processing and analysis. Parameters governing the performance characteristics of the system were measured. A spatial resolution limit of 31 +/- 2 microns (1 sigma) corresponding to 16 +/- 1 line pairs/mm measured at themore » 4% level of the modulation transfer function has been achieved. The full width at half maximum of the line spread function measured independently by the slit method or derived from the edge response function was found to be 69 +/- 4 microns (1 sigma). The high resolving power, speed of readout, good precision, wide dynamic range, and the large image storage capacity make the system suitable for the digital mapping of the relative distribution of absorbed doses for various small radiation fields and the edges of larger fields.« less
Measuring Attention in the Hemispheres: The Lateralized Attention Network Test (LANT)
ERIC Educational Resources Information Center
Greene, Deanna J.; Barnea, Anat; Herzberg, Kristin; Rassis, Anat; Neta, Maital; Raz, Amir; Zaidel, Eran
2008-01-01
The attention network test (ANT) is a brief computerized battery measuring three independent behavioral components of attention: Conflict resolution (ability to overcome distracting stimuli), spatial Orienting (the benefit of valid spatial pre-cues), and Alerting (the benefit of temporal pre-cues). Imaging, clinical, and behavioral evidence…
Nike Facility Diagnostics and Data Acquisition System
NASA Astrophysics Data System (ADS)
Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim
2013-10-01
The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martins de Oliveira, Jose Jr.; Germano Martins, Antonio Cesar
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 mum was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques.
Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin
2017-07-27
This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.
Acoustic beam control in biomimetic projector via velocity gradient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Xiaowei; Dong, Erqian; Song, Zhongchang
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Acoustic beam control in biomimetic projector via velocity gradient
NASA Astrophysics Data System (ADS)
Gao, Xiaowei; Zhang, Yu; Cao, Wenwu; Dong, Erqian; Song, Zhongchang; Li, Songhai; Tang, Liguo; Zhang, Sai
2016-07-01
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Severity of Organized Item Theft in Computerized Adaptive Testing: A Simulation Study
ERIC Educational Resources Information Center
Yi, Qing; Zhang, Jinming; Chang, Hua-Hua
2008-01-01
Criteria had been proposed for assessing the severity of possible test security violations for computerized tests with high-stakes outcomes. However, these criteria resulted from theoretical derivations that assumed uniformly randomized item selection. This study investigated potential damage caused by organized item theft in computerized adaptive…
Microstructural analysis of aluminum high pressure die castings
NASA Astrophysics Data System (ADS)
David, Maria Diana
Microstructural analysis of aluminum high pressure die castings (HPDC) is challenging and time consuming. Automating the stereology method is an efficient way in obtaining quantitative data; however, validating the accuracy of this technique can also pose some challenges. In this research, a semi-automated algorithm to quantify microstructural features in aluminum HPDC was developed. Analysis was done near the casting surface where it exhibited fine microstructure. Optical and Secondary electron (SE) and backscatter electron (BSE) SEM images were taken to characterize the features in the casting. Image processing steps applied on SEM and optical micrographs included median and range filters, dilation, erosion, and a hole-closing function. Measurements were done on different image pixel resolutions that ranged from 3 to 35 pixel/μm. Pixel resolutions below 6 px/μm were too low for the algorithm to distinguish the phases from each other. At resolutions higher than 6 px/μm, the volume fraction of primary α-Al and the line intercept count curves plateaued. Within this range, comparable results were obtained validating the assumption that there is a range of image pixel resolution relative to the size of the casting features at which stereology measurements become independent of the image resolution. Volume fraction within this curve plateau was consistent with the manual measurements while the line intercept count was significantly higher using the computerized technique for all resolutions. This was attributed to the ragged edges of some primary α-Al; hence, the algorithm still needs some improvements. Further validation of the code using other castings or alloys with known phase amount and size may also be beneficial.
Spatial super-resolution of colored images by micro mirrors
NASA Astrophysics Data System (ADS)
Dahan, Daniel; Yaacobi, Ami; Pinsky, Ephraim; Zalevsky, Zeev
2018-06-01
In this paper, we present two methods of dealing with the geometric resolution limit of color imaging sensors. It is possible to overcome the pixel size limit by adding a digital micro-mirror device component on the intermediate image plane of an optical system, and adapting its pattern in a computerized manner before sampling each frame. The full RGB image can be reconstructed from the Bayer camera by building a dedicated optical design, or by adjusting the demosaicing process to the special format of the enhanced image.
Classification and Current Management of Inner Ear Malformations.
Sennaroğlu, Levent; Bajin, Münir Demir
2017-09-29
Morphologically congenital sensorineural hearing loss can be investigated under two categories. The majority of congenital hearing loss causes (80%) are membranous malformations. Here, the pathology involves inner ear hair cells. There is no gross bony abnormality and, therefore, in these cases high-resolution computerized tomography and magnetic resonance imaging of the temporal bone reveal normal findings. The remaining 20% have various malformations involving the bony labyrinth and, therefore, can be radiologically demonstrated by computerized tomography and magnetic resonance imaging. The latter group involves surgical challenges as well as problems in decision-making. Some cases may be managed by a hearing aid, others need cochlear implantation, and some cases are candidates for an auditory brainstem implantation (ABI). During cochlear implantation, there may be facial nerve abnormalities, cerebrospinal fluid leakage, electrode misplacement or difficulty in finding the cochlea itself. During surgery for inner ear malformations, the surgeon must be ready to modify the surgical approach or choose special electrodes for surgery. In the present review article, inner ear malformations are classified according to the differences observed in the cochlea. Hearing and language outcomes after various implantation methods are closely related to the status of the cochlear nerve, and a practical classification of the cochlear nerve deficiency is also provided.
NASA Astrophysics Data System (ADS)
Tylen, Ulf; Friman, Ola; Borga, Magnus; Angelhed, Jan-Erik
2001-05-01
Emphysema is characterized by destruction of lung tissue with development of small or large holes within the lung. These areas will have Hounsfield values (HU) approaching -1000. It is possible to detect and quantificate such areas using simple density mask technique. The edge enhancement reconstruction algorithm, gravity and motion of the heart and vessels during scanning causes artefacts, however. The purpose of our work was to construct an algorithm that detects such image artefacts and corrects them. The first step is to apply inverse filtering to the image removing much of the effect of the edge enhancement reconstruction algorithm. The next step implies computation of the antero-posterior density gradient caused by gravity and correction for that. Motion artefacts are in a third step corrected for by use of normalized averaging, thresholding and region growing. Twenty healthy volunteers were investigated, 10 with slight emphysema and 10 without. Using simple density mask technique it was not possible to separate persons with disease from those without. Our algorithm improved separation of the two groups considerably. Our algorithm needs further refinement, but may form a basis for further development of methods for computerized diagnosis and quantification of emphysema by HRCT.
Antipsychotic treatment in schizophrenia: the role of computerized neuropsychological assessment.
Kertzman, Semion; Reznik, Ilya; Grinspan, Haim; Weizman, Abraham; Kotler, Moshe
2008-01-01
The present study analyzes the role of neurocognitive assessment instruments in the detection of the contribution of antipsychotic treatment to cognitive functioning. Recently, a panel of experts suggested six main domains (working memory; attention/vigilance; verbal/visual learning and memory; reasoning and problem solving; speed of processing) implicated in schizophrenia-related cognitive deficits, which serve as a theoretical base for creation of real-time computerized neurocognitive batteries. The high sensitivity of computerized neuropsychological testing is based on their ability to adopt the reaction time (RT) paradigm for the assessment of brain function in a real-time regime. This testing is highly relevant for the monitoring of the cognitive effects of antipsychotics. Computerized assessment assists in the identification of state- and trait-related cognitive impairments. The optimal real-time computerized neurocognitive battery should composite balance between broad and narrow coverage of cognitive domains relevant to the beneficial effects of antipsychotics and will enable better planning of treatment and rehabilitation programs.
ERIC Educational Resources Information Center
Dori, Yehudit J.; Sasson, Irit
2008-01-01
The case-based computerized laboratory (CCL) is a chemistry learning environment that integrates computerized experiments with emphasis on scientific inquiry and comprehension of case studies. The research objective was to investigate chemical understanding and graphing skills of high school honors students via bidirectional visual and textual…
Improving Scores on Computerized Reading Assessments: The Effects of Colored Overlay Use
ERIC Educational Resources Information Center
Adams, Tracy A.
2012-01-01
Visual stress is a perceptual dysfunction that appears to affect how information is processed as it passes from the eyes to the brain. Photophobia, visual resolution, restricted focus, sustaining focus, and depth perception are all components of visual stress. Because visual stress affects what is perceived by the eye, students with this disorder…
Absolute accuracy of the Cyberware WB4 whole-body scanner
NASA Astrophysics Data System (ADS)
Daanen, Hein A. M.; Taylor, Stacie E.; Brunsman, Matthew A.; Nurre, Joseph H.
1997-03-01
The Cyberware WB4 whole body scanner is one of the first scanning systems in the world that generates a high resolution data set of the outer surface of the human body. The Computerized Anthropometric Research and Design (CARD) Laboratory of Wright-Patterson AFB intends to use the scanner to enable quick and reliable acquisition of anthropometric data. For this purpose, a validation study was initiated to check the accuracy, reliability and errors of the system. A calibration object, consisting of two boxes and a cylinder, was scanned in several locations in the scanning space. The object dimensions in the resulting scans compared favorably to the actual dimensions of the calibration object.
Mu, Zhiping; Hong, Baoming; Li, Shimin; Liu, Yi-Hwa
2009-01-01
Coded aperture imaging for two-dimensional (2D) planar objects has been investigated extensively in the past, whereas little success has been achieved in imaging 3D objects using this technique. In this article, the authors present a novel method of 3D single photon emission computerized tomography (SPECT) reconstruction for near-field coded aperture imaging. Multiangular coded aperture projections are acquired and a stack of 2D images is reconstructed separately from each of the projections. Secondary projections are subsequently generated from the reconstructed image stacks based on the geometry of parallel-hole collimation and the variable magnification of near-field coded aperture imaging. Sinograms of cross-sectional slices of 3D objects are assembled from the secondary projections, and the ordered subset expectation and maximization algorithm is employed to reconstruct the cross-sectional image slices from the sinograms. Experiments were conducted using a customized capillary tube phantom and a micro hot rod phantom. Imaged at approximately 50 cm from the detector, hot rods in the phantom with diameters as small as 2.4 mm could be discerned in the reconstructed SPECT images. These results have demonstrated the feasibility of the authors’ 3D coded aperture image reconstruction algorithm for SPECT, representing an important step in their effort to develop a high sensitivity and high resolution SPECT imaging system. PMID:19544769
Multidimensional Computerized Adaptive Testing for Indonesia Junior High School Biology
ERIC Educational Resources Information Center
Kuo, Bor-Chen; Daud, Muslem; Yang, Chih-Wei
2015-01-01
This paper describes a curriculum-based multidimensional computerized adaptive test that was developed for Indonesia junior high school Biology. In adherence to the Indonesian curriculum of different Biology dimensions, 300 items was constructed, and then tested to 2238 students. A multidimensional random coefficients multinomial logit model was…
Advanced Technology Training Program for the Apparel Industry. Final Report.
ERIC Educational Resources Information Center
El Paso Community Coll., TX.
A project developed rapid response, advanced technology courses that met the apparel market labor needs of the El Paso (Texas) community. Courses were designed for four options: computerized marker making and pattern grading, computerized front office systems, high technology machinery operation, and high technology machinery mechanics. The…
Computer programs: Mechanical and structural design criteria: A compilation
NASA Technical Reports Server (NTRS)
1973-01-01
Computerized design criteria for turbomachinery and the constraints imposed by very high rotational fields are presented along with a variety of computerized design criteria of interest to structural designers.
Ground truth management system to support multispectral scanner /MSS/ digital analysis
NASA Technical Reports Server (NTRS)
Coiner, J. C.; Ungar, S. G.
1977-01-01
A computerized geographic information system for management of ground truth has been designed and implemented to relate MSS classification results to in situ observations. The ground truth system transforms, generalizes and rectifies ground observations to conform to the pixel size and shape of high resolution MSS aircraft data. These observations can then be aggregated for comparison to lower resolution sensor data. Construction of a digital ground truth array allows direct pixel by pixel comparison between classification results of MSS data and ground truth. By making comparisons, analysts can identify spatial distribution of error within the MSS data as well as usual figures of merit for the classifications. Use of the ground truth system permits investigators to compare a variety of environmental or anthropogenic data, such as soil color or tillage patterns, with classification results and allows direct inclusion of such data into classification operations. To illustrate the system, examples from classification of simulated Thematic Mapper data for agricultural test sites in North Dakota and Kansas are provided.
MacDonald, James; Duerson, Drew
2015-07-01
Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loo, B.W. Jr.
High resolution x-ray microscopy has been made possible in recent years primarily by two new technologies: microfabricated diffractive lenses for soft x-rays with about 30-50 nm resolution, and high brightness synchrotron x-ray sources. X-ray microscopy occupies a special niche in the array of biological microscopic imaging methods. It extends the capabilities of existing techniques mainly in two areas: a previously unachievable combination of sub-visible resolution and multi-micrometer sample size, and new contrast mechanisms. Because of the soft x-ray wavelengths used in biological imaging (about 1-4 nm), XM is intermediate in resolution between visible light and electron microscopies. Similarly, the penetrationmore » depth of soft x-rays in biological materials is such that the ideal sample thickness for XM falls in the range of 0.25 - 10 {mu}m, between that of VLM and EM. XM is therefore valuable for imaging of intermediate level ultrastructure, requiring sub-visible resolutions, in intact cells and subcellular organelles, without artifacts produced by thin sectioning. Many of the contrast producing and sample preparation techniques developed for VLM and EM also work well with XM. These include, for example, molecule specific staining by antibodies with heavy metal or fluorescent labels attached, and sectioning of both frozen and plastic embedded tissue. However, there is also a contrast mechanism unique to XM that exists naturally because a number of elemental absorption edges lie in the wavelength range used. In particular, between the oxygen and carbon absorption edges (2.3 and 4.4 nm wavelength), organic molecules absorb photons much more strongly than does water, permitting element-specific imaging of cellular structure in aqueous media, with no artifically introduced contrast agents. For three-dimensional imaging applications requiring the capabilities of XM, an obvious extension of the technique would therefore be computerized x-ray microtomography (XMT).« less
ERIC Educational Resources Information Center
Lang, Robin Lynn Neal
2012-01-01
A growing national emphasis has been placed on health information technology (HIT) with robust computerized clinical decision support (CCDS) integration into health care delivery. Catheter-associated urinary tract infection is the most frequent health care-associated infection in the United States and is associated with high cost, high volumes and…
Clinical confocal microlaparoscope for real-time in vivo optical biopsies
NASA Astrophysics Data System (ADS)
Tanbakuchi, Anthony A.; Rouse, Andrew R.; Udovich, Joshua A.; Hatch, Kenneth D.; Gmitro, Arthur F.
2009-07-01
Successful treatment of cancer is highly dependent on the stage at which it is diagnosed. Early diagnosis, when the disease is still localized at its origin, results in very high cure rates-even for cancers that typically have poor prognosis. Biopsies are often used for diagnosis of disease. However, because biopsies are destructive, only a limited number can be taken. This leads to reduced sensitivity for detection due to sampling error. A real-time fluorescence confocal microlaparoscope has been developed that provides instant in vivo cellular images, comparable to those provided by histology, through a nondestructive procedure. The device includes an integrated contrast agent delivery mechanism and a computerized depth scan system. The instrument uses a fiber bundle to relay the image plane of a slit-scan confocal microlaparoscope into tissue. It has a 3-μm lateral resolution and a 25-μm axial resolution. Initial in vivo clinical testing using the device to image human ovaries has been done in 21 patients. Results indicate that the device can successfully image organs in vivo without complications. Results with excised tissue demonstrate that the instrument can resolve sufficient cellular detail to visualize the cellular changes associated with the onset of cancer.
DOE R&D Accomplishments Database
Hansche, B. D.
1983-01-01
Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.
ERIC Educational Resources Information Center
Arutunian, Carol Ann
The Computerized Vocational Information System (CVIS) at Willowbrook High School in Villa Park, Illinois, uses the computer as a tool to help each student explore a wide range of occupations and educational opportunities with some feedback from his own record of ability, achievement, and interest. Computer-based guidance systems are considered a…
NASA Astrophysics Data System (ADS)
Voeikov, Vladimir L.; Kondakov, Sergey E.; Buravleva, Ekaterina; Kaganovsky, Isaak; Reznikov, Mikhail
2000-05-01
An automatic device for high-temporal resolution of the process of red blood sedimentation was designed. The position of the boundary between red blood and plasma may be registered each 30 sec in several pipettes simultaneously with +/- 10 mkm precision. Fractional rates of the boundary movement are deduced with high accuracy. Data are processed by a PC and presented as velocity-time curves (ESR-grams) and the curves describing time evolution of the boundary position. Several unexpected phenomena in the process of red blood sedimentation have been revealed. Upward fast movements of the boundary up to 1 mm were noted. In patients' blood sets of 5 - 10 milliHz oscillations of sedimentation rate were usually developing at early stages of blood sedimentation. In non-diluted healthy donors' blood high amplitude periodic oscillations were either absent, or were emerging only after blood resided in pipettes for several hours. When blood was diluted to a certain degree with physiological saline or with own plasma long-term low frequency (1 - 3 milliHz) rate oscillations regularly appeared. Non-trivial dependence of patterns of ESR-grams on diluting of blood with own plasma or saline was observed. Thus, non-linear dynamic behavior of living blood has been revealed due to application of the principles of the system of technical vision for the detailed analysis of red blood sedimentation kinetics.
ERIC Educational Resources Information Center
Allan, Blaine W.
In 1963 Stanford University selected Virgin Valley High School in southern Nevada as one of four pilot schools to use computerized modular scheduling. Schedules for 165 students and assignments for 14 teachers were developed at the Stanford University Computer Computation Center using 30-minute modules with a total of 80 modules per week. After…
[The clinical economic analysis of the methods of ischemic heart disease diagnostics].
Kalashnikov, V Iu; Mitriagina, S N; Syrkin, A L; Poltavskaia, M G; Sorokina, E G
2007-01-01
The clinical economical analysis was applied to assess the application of different techniques of ischemic heart disease diagnostics - the electro-cardiographic monitoring, the treadmill-testing, the stress-echo cardiographic with dobutamine, the single-photon computerized axial tomography with load, the multi-spiral computerized axial tomography with coronary arteries staining in patients with different initial probability of disease occurrence. In all groups, the best value of "cost-effectiveness" had the treadmill-test. The patients with low risk needed 17.4 rubles to precise the probability of ischemic heart disease occurrence at 1%. In the group with medium and high risk this indicator was 9.4 and 24.7 rubles correspondingly. It is concluded that to precise the probability of ischemic heart disease occurrence after tredmil-test in the patients with high probability it is appropriate to use the single-photon computerized axial tomography with load and in the case of patients with low probability the multi-spiral computerized axial tomography with coronary arteries staining.
NASA Astrophysics Data System (ADS)
Chang Chien, Kuang-Che; Fetita, Catalin; Brillet, Pierre-Yves; Prêteux, Françoise; Chang, Ruey-Feng
2009-02-01
Multi-detector computed tomography (MDCT) has high accuracy and specificity on volumetrically capturing serial images of the lung. It increases the capability of computerized classification for lung tissue in medical research. This paper proposes a three-dimensional (3D) automated approach based on mathematical morphology and fuzzy logic for quantifying and classifying interstitial lung diseases (ILDs) and emphysema. The proposed methodology is composed of several stages: (1) an image multi-resolution decomposition scheme based on a 3D morphological filter is used to detect and analyze the different density patterns of the lung texture. Then, (2) for each pattern in the multi-resolution decomposition, six features are computed, for which fuzzy membership functions define a probability of association with a pathology class. Finally, (3) for each pathology class, the probabilities are combined up according to the weight assigned to each membership function and two threshold values are used to decide the final class of the pattern. The proposed approach was tested on 10 MDCT cases and the classification accuracy was: emphysema: 95%, fibrosis/honeycombing: 84% and ground glass: 97%.
The effect of sleep deprivation on vocal expression of emotion in adolescents and adults.
McGlinchey, Eleanor L; Talbot, Lisa S; Chang, Keng-Hao; Kaplan, Katherine A; Dahl, Ronald E; Harvey, Allison G
2011-09-01
Investigate the impact of sleep deprivation on vocal expression of emotion. Within-group repeated measures analysis involving sleep deprivation and rested conditions. Experimental laboratory setting. Fifty-five healthy participants (24 females), including 38 adolescents aged 11-15 y and 17 adults aged 30-60 y. A multimethod approach was used to examine vocal expression of emotion in interviews conducted at 22:30 and 06:30. On that night, participants slept a maximum of 2 h. Interviews were analyzed for vocal expression of emotion via computerized text analysis, human rater judgments, and computerized acoustic properties. Computerized text analysis and human rater judgments indicated decreases in positive emotion in all participants at 06:30 relative to 22:30, and adolescents displayed a significantly greater decrease in positive emotion via computerized text analysis relative to adults. Increases in negative emotion were observed among all participants using human rater judgments. Results for the computerized acoustic properties indicated decreases in pitch, bark energy (intensity) in certain high frequency bands, and vocal sharpness (reduction in high frequency bands > 1000 Hz). These findings support the importance of sleep for healthy emotional functioning in adults, and further suggest that adolescents are differentially vulnerable to the emotional consequences of sleep deprivation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGoldrick, P.R.
1981-01-01
The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control roommore » consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed.« less
A novel intra-operative, high-resolution atrial mapping approach.
Yaksh, Ameeta; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Oei, Frans B S; van de Woestijne, Pieter C; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S
2015-12-01
A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.
Podshivalov, L; Fischer, A; Bar-Yoseph, P Z
2011-04-01
This paper describes a new alternative for individualized mechanical analysis of bone trabecular structure. This new method closes the gap between the classic homogenization approach that is applied to macro-scale models and the modern micro-finite element method that is applied directly to micro-scale high-resolution models. The method is based on multiresolution geometrical modeling that generates intermediate structural levels. A new method for estimating multiscale material properties has also been developed to facilitate reliable and efficient mechanical analysis. What makes this method unique is that it enables direct and interactive analysis of the model at every intermediate level. Such flexibility is of principal importance in the analysis of trabecular porous structure. The method enables physicians to zoom-in dynamically and focus on the volume of interest (VOI), thus paving the way for a large class of investigations into the mechanical behavior of bone structure. This is one of the very few methods in the field of computational bio-mechanics that applies mechanical analysis adaptively on large-scale high resolution models. The proposed computational multiscale FE method can serve as an infrastructure for a future comprehensive computerized system for diagnosis of bone structures. The aim of such a system is to assist physicians in diagnosis, prognosis, drug treatment simulation and monitoring. Such a system can provide a better understanding of the disease, and hence benefit patients by providing better and more individualized treatment and high quality healthcare. In this paper, we demonstrate the feasibility of our method on a high-resolution model of vertebra L3. Copyright © 2010 Elsevier Inc. All rights reserved.
In Search of Effective Methodology for Organizational Learning: A Japanese Experience
ERIC Educational Resources Information Center
Tsuchiya, Shigehisa
2011-01-01
The author's personal journey regarding simulation and gaming started about 25 years ago when he happened to realize how powerful computerized simulation could be for organizational change. The metaphors created by computerized simulation enabled him to transform a stagnant university into a high-performance organization. Through extensive…
A Computerized System for Measuring Detection Sensitivity over the Visual Field,
1986-06-01
variety of conditions can act to degrade this basic configuration of detection capability; e.g., pathology, such as glaucoma and retinitis pigmentosa ...the central line of sight involving the retinal fovea is clearly the locus of greatest visual resolution under photopic viewing conditions, the...Skills. 1974; 41:467-474. 6. Kobrick JL, Appleton S. Effects of hypoxia on visual performance and retinal vascular state. J. Appl. Physiol. 1971; 31:357
Evaluation of Used Crankcase Oils Using Computerized Infrared Spectrometry. Appendices.
1984-06-01
JUN 84 J0AP-TSC-84-81-APP F/G 20/6 ’ NL BBBBBBB •Tva-.j’.-n^r. r.T T.~C^ 01^ lite MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU OF...7>- a—-»tc-o ru" »Tier be vrf ->or-co. O SNOOCOOx IVOO 5COO!oOo 5COO 30 irm-i- ivmoc orc>0 •circec OP<IVNI ^l^Of«•. oc
Supporting Patient Care in the Emergency Department with a Computerized Whiteboard System
Aronsky, Dominik; Jones, Ian; Lanaghan, Kevin; Slovis, Corey M.
2008-01-01
Efficient information management and communication within the emergency department (ED) is essential to providing timely and high-quality patient care. The ED whiteboard (census board) usually serves as an ED’s central access point for operational and patient-related information. This article describes the design, functionality, and experiences with a computerized ED whiteboard, which has the ability to display relevant operational and patient-related information in real time. Embedded functionality, additional whiteboard views, and the integration with ED and institutional information system components, such as the computerized patient record or the provider order entry system, provide rapid access to more detailed information. As an information center, the computerized whiteboard supports our ED environment not only for providing patient care, but also for operational, educational, and research activities. PMID:18096913
Gerloni, Alessandro; Cavalli, Fabio; Costantinides, Fulvio; Costantinides, Fulvia; Bonetti, Stefano; Paganelli, Corrado
2009-06-01
The aim of the study was to provide a paleopathologic and radiologic overview of the jaws and teeth of 3 Egyptian mummies preserved in the Civic Museum of History and Art in Trieste. Computerized tomography (CT) imaging and postprocessing techniques were used to examine the oral structures. A 16-slice CT scanner was used (Aquilion 16; Toshiba Medical Systems Europe, Zoetermeer, The Netherlands). Scans were obtained at high resolution. Orthogonal-plane and 3-dimensional (3D) reconstructions were created along with curved reconstructions of the lower and upper jaws. Determination of decayed/missing teeth (DMT) and decayed/missing/tooth surfaces (DMTs) were made with 3D images. Analyses revealed differences in the embalming techniques and state of preservation of the bodies. Marked wear of the occlusal surfaces was a characteristic finding in all of the mummies. The DMT and DMTs were low compared with values for contemporary populations. Two mummies had fully erupted third molars. All mummies exhibited bone changes consistent with periodontitis. The CT evaluations of the oral structures of the mummies provided insight into the dental status and oral diseases of these ancient Egyptians. The low DMT and DMTs values and indications of periodontitis may be associated with the lifestyle of these Egyptians. The fully erupted and well aligned third molars may represent a morphologic adaptation of the arches to the muscular activity associated with grinding tough foods.
Dodani, Sunjay S; Lu, Charles W; Aldridge, J Wayne; Chou, Kelvin L; Patil, Parag G
2018-06-01
Accurate electrode placement is critical to the success of deep brain stimulation (DBS) surgery. Suboptimal targeting may arise from poor initial target localization, frame-based targeting error, or intraoperative brain shift. These uncertainties can make DBS surgery challenging. To develop a computerized system to guide subthalamic nucleus (STN) DBS electrode localization and to estimate the trajectory of intraoperative microelectrode recording (MER) on magnetic resonance (MR) images algorithmically during DBS surgery. Our method is based upon the relationship between the high-frequency band (HFB; 500-2000 Hz) signal from MER and voxel intensity on MR images. The HFB profile along an MER trajectory recorded during surgery is compared to voxel intensity profiles along many potential trajectories in the region of the surgically planned trajectory. From these comparisons of HFB recordings and potential trajectories, an estimate of the MER trajectory is calculated. This calculated trajectory is then compared to actual trajectory, as estimated by postoperative high-resolution computed tomography. We compared 20 planned, calculated, and actual trajectories in 13 patients who underwent STN DBS surgery. Targeting errors for our calculated trajectories (2.33 mm ± 0.2 mm) were significantly less than errors for surgically planned trajectories (2.83 mm ± 0.2 mm; P = .01), improving targeting prediction in 70% of individual cases (14/20). Moreover, in 4 of 4 initial MER trajectories that missed the STN, our method correctly indicated the required direction of targeting adjustment for the DBS lead to intersect the STN. A computer-based algorithm simultaneously utilizing MER and MR information potentially eases electrode localization during STN DBS surgery.
Cooper, W C
1985-01-01
The various congenital and acquired conditions which alter orbital volume are reviewed. Previous investigative work to determine orbital capacity is summarized. Since these studies were confined to postmortem evaluations, the need for a technique to measure orbital volume in the living state is presented. A method for volume determination of the orbit and its contents by high-resolution axial tomography and quantitative digital image analysis is reported. This procedure has proven to be accurate (the discrepancy between direct and computed measurements ranged from 0.2% to 4%) and reproducible (greater than 98%). The application of this method to representative clinical problems is presented and discussed. The establishment of a diagnostic system versatile enough to expand the usefulness of computerized axial tomography and polytomography should add a new dimension to ophthalmic investigation and treatment. Images FIGURE 8 FIGURE 9 FIGURE 10 A FIGURE 10 B FIGURE 11 A FIGURE 11 B FIGURE 12 FIGURE 13 FIGURE 14 FIGURE 15 FIGURE 16 FIGURE 17 FIGURE 18 FIGURE 19 FIGURE 20 FIGURE 21 FIGURE 22 FIGURE 23 FIGURE 24 FIGURE 25 FIGURE 26 A FIGURE 26 B FIGURE 27 FIGURE 28 FIGURE 29 FIGURE 30 FIGURE 31 FIGURE 32 PMID:3938582
A computerized Langmuir probe system
NASA Astrophysics Data System (ADS)
Pilling, L. S.; Bydder, E. L.; Carnegie, D. A.
2003-07-01
For low pressure plasmas it is important to record entire single or double Langmuir probe characteristics accurately. For plasmas with a depleted high energy tail, the accuracy of the recorded ion current plays a critical role in determining the electron temperature. Even for high density Maxwellian distributions, it is necessary to accurately model the ion current to obtain the correct electron density. Since the electron and ion current saturation values are, at best, orders of magnitude apart, a single current sensing resistor cannot provide the required resolution to accurately record these values. We present an automated, personal computer based data acquisition system for the determination of fundamental plasma properties in low pressure plasmas. The system is designed for single and double Langmuir probes, whose characteristics can be recorded over a bias voltage range of ±70 V with 12 bit resolution. The current flowing through the probes can be recorded within the range of 5 nA-100 mA. The use of a transimpedance amplifier for current sensing eliminates the requirement for traditional current sensing resistors and hence the need to correct the raw data. The large current recording range is realized through the use of a real time gain switching system in the negative feedback loop of the transimpedance amplifier.
ERIC Educational Resources Information Center
Reychav, Iris; Raban, Daphne Ruth; McHaney, Roger
2018-01-01
The current empirical study examines relationships between network measures and learning performance from a social network analysis perspective. We collected computerized, networking data to analyze how 401 junior high students connected to classroom peers using text- and video-based material on iPads. Following a period of computerized…
ERIC Educational Resources Information Center
Ponsoda, Vicente; Olea, Julio; Rodriguez, Maria Soledad; Revuelta, Javier
1999-01-01
Compared easy and difficult versions of self-adapted tests (SAT) and computerized adapted tests. No significant differences were found among the tests for estimated ability or posttest state anxiety in studies with 187 Spanish high school students, although other significant differences were found. Discusses implications for interpreting test…
Optimal Item Pool Design for a Highly Constrained Computerized Adaptive Test
ERIC Educational Resources Information Center
He, Wei
2010-01-01
Item pool quality has been regarded as one important factor to help realize enhanced measurement quality for the computerized adaptive test (CAT) (e.g., Flaugher, 2000; Jensema, 1977; McBride & Wise, 1976; Reckase, 1976; 2003; van der Linden, Ariel, & Veldkamp, 2006; Veldkamp & van der Linden, 2000; Xing & Hambleton, 2004). However, studies are…
Wong, Adrian; Fong, Ching-Hang; Mok, Vincent Chung-Tong; Leung, Kam-Tat; Tong, Raymond Kai-Yu
2017-01-01
Computerized cognitive tests may serve as a preliminary, low-cost method to identify individuals with suspected cognitive impairment in the community. To develop a self-administered computerized test, namely the "Computerized Cognitive Screen (CoCoSc), Hong Kong version", for screening of individuals with cognitive impairment (CI) in community settings. The CoCoSc is a 15-min computerized cognitive screen covering memory, executive functions, orientation, attention and working memory, and prospective memory administered on a touchscreen computer. Individuals with CI and cognitively normal controls were administered the CoCoSc and the Montreal Cognitive Assessment (MoCA). Validity of the CoCoSc was assessed based on the relationship with the MoCA using Pearson correlation. Receiver operating characteristic curve (ROC) was used to examine the ability of the CoCoSc to differentiate CI from controls. Fifty-nine individuals with CI and 101 controls were recruited. Seventy-five (46.9%) participants had ≤6 years of education. Performance on the CoCoSc differed between normal and CI groups in both low and high education subgroups. Total scores of the CoCoSc and MoCA were significantly correlated (r = 0.71, p < 0.001). The area under ROC was 0.78, p < 0.001 for the CoCoSc total score in differentiating the CI group from the cognitively normal group. A cut-off of ≤30 on the CoCoSc was associated with a sensitivity of 0.78 and specificity of 0.69. The CoCoSc was well accepted by attendees of community social centers. The CoCoSc is a promising computerized cognitive screen for self-administration in community social centers. It is feasible for testing individuals with high or low education levels.
Jafarpour, Borna; Abidi, Samina Raza; Abidi, Syed Sibte Raza
2016-01-01
Computerizing paper-based CPG and then executing them can provide evidence-informed decision support to physicians at the point of care. Semantic web technologies especially web ontology language (OWL) ontologies have been profusely used to represent computerized CPG. Using semantic web reasoning capabilities to execute OWL-based computerized CPG unties them from a specific custom-built CPG execution engine and increases their shareability as any OWL reasoner and triple store can be utilized for CPG execution. However, existing semantic web reasoning-based CPG execution engines suffer from lack of ability to execute CPG with high levels of expressivity, high cognitive load of computerization of paper-based CPG and updating their computerized versions. In order to address these limitations, we have developed three CPG execution engines based on OWL 1 DL, OWL 2 DL and OWL 2 DL + semantic web rule language (SWRL). OWL 1 DL serves as the base execution engine capable of executing a wide range of CPG constructs, however for executing highly complex CPG the OWL 2 DL and OWL 2 DL + SWRL offer additional executional capabilities. We evaluated the technical performance and medical correctness of our execution engines using a range of CPG. Technical evaluations show the efficiency of our CPG execution engines in terms of CPU time and validity of the generated recommendation in comparison to existing CPG execution engines. Medical evaluations by domain experts show the validity of the CPG-mediated therapy plans in terms of relevance, safety, and ordering for a wide range of patient scenarios.
Fiber Optic Communication System For Medical Images
NASA Astrophysics Data System (ADS)
Arenson, Ronald L.; Morton, Dan E.; London, Jack W.
1982-01-01
This paper discusses a fiber optic communication system linking ultrasound devices, Computerized tomography scanners, Nuclear Medicine computer system, and a digital fluoro-graphic system to a central radiology research computer. These centrally archived images are available for near instantaneous recall at various display consoles. When a suitable laser optical disk is available for mass storage, more extensive image archiving will be added to the network including digitized images of standard radiographs for comparison purposes and for remote display in such areas as the intensive care units, the operating room, and selected outpatient departments. This fiber optic system allows for a transfer of high resolution images in less than a second over distances exceeding 2,000 feet. The advantages of using fiber optic cables instead of typical parallel or serial communication techniques will be described. The switching methodology and communication protocols will also be discussed.
A rare case of ethambutol induced pulmonary eosinophilia
Saha, Kaushik; Bandyopadhyay, Ankan; Sengupta, Amitabha; Jash, Debraj
2013-01-01
Antitubercular drug (ATD) induced eosinophilic lung disease is a rare phenomenon. It usually occurs due to isoniazid and para amino salicylic acid. A 34-year-male of sputum positive pulmonary tuberculosis, on antitubercular drugs (rifampicin, isoniazid, ethambutol, and pyrazinamide) for last 3 weeks, presented with generalized arthralgia and maculopapular rash for last 2 weeks and shortness of breath for last 1 week. Chest X-ray and High resolution computerized tomographic scan thorax showed bilateral peripheral airspace opacification. Bronchoalveolar lavage revealed 51% eosinophils of total cellularity (1200/cmm) confirming the diagnosis of pulmonary eosinophilia. ATD was stopped for 2 weeks and then reintroduced one by one. Patient again developed similar kind of symptoms with reintroduction of ethambutol. According to criteria for drug induced pulmonary eosinophilia, he was diagnosed as a case of ethambutol induced pulmonary eosinophilia. PMID:24250213
ERIC Educational Resources Information Center
Yi, Qing; Zhang, Jinming; Chang, Hua-Hua
2006-01-01
Chang and Zhang (2002, 2003) proposed several baseline criteria for assessing the severity of possible test security violations for computerized tests with high-stakes outcomes. However, these criteria were obtained from theoretical derivations that assumed uniformly randomized item selection. The current study investigated potential damage caused…
The Computerized Educational Guidance System. EDGUYD Manual.
ERIC Educational Resources Information Center
Cassel, Russell N.
The Computerized Educational Guidance System (EDGUYD) permits one to narrow post high school educational planning where consideration is given to all 1,448 4-year colleges and universities in the United States. This, to be sure, is a feat no human counselor is capable of without a computer. The Educational Success Index (ESI) is the means used by…
Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto
2014-01-01
To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, p<0.001); satisfaction decreased with age (p<0.001). Physicians scored lower concerning the potential of the computerized physician order entry for improving patient safety (5.45±2.20 versus 8.09±2.21, p<0.001) and the ease of using the computerized physician order entry (3.83±1.88 versus 6.44±2.31, p<0.001). The characteristics independently associated with satisfaction were the system's user-friendliness, accuracy, capacity to provide clear information, and fast response time. Six months after its implementation, healthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.
Disclosure of sensitive behaviors across self-administered survey modes: a meta-analysis.
Gnambs, Timo; Kaspar, Kai
2015-12-01
In surveys, individuals tend to misreport behaviors that are in contrast to prevalent social norms or regulations. Several design features of the survey procedure have been suggested to counteract this problem; particularly, computerized surveys are supposed to elicit more truthful responding. This assumption was tested in a meta-analysis of survey experiments reporting 460 effect sizes (total N =125,672). Self-reported prevalence rates of several sensitive behaviors for which motivated misreporting has been frequently observed were compared across self-administered paper-and-pencil versus computerized surveys. The results revealed that computerized surveys led to significantly more reporting of socially undesirable behaviors than comparable surveys administered on paper. This effect was strongest for highly sensitive behaviors and surveys administered individually to respondents. Moderator analyses did not identify interviewer effects or benefits of audio-enhanced computer surveys. The meta-analysis highlighted the advantages of computerized survey modes for the assessment of sensitive topics.
NASA Technical Reports Server (NTRS)
Drury, H. A.; Van Essen, D. C.; Anderson, C. H.; Lee, C. W.; Coogan, T. A.; Lewis, J. W.
1996-01-01
We present a new method for generating two-dimensional maps of the cerebral cortex. Our computerized, two-stage flattening method takes as its input any well-defined representation of a surface within the three-dimensional cortex. The first stage rapidly converts this surface to a topologically correct two-dimensional map, without regard for the amount of distortion introduced. The second stage reduces distortions using a multiresolution strategy that makes gross shape changes on a coarsely sampled map and further shape refinements on progressively finer resolution maps. We demonstrate the utility of this approach by creating flat maps of the entire cerebral cortex in the macaque monkey and by displaying various types of experimental data on such maps. We also introduce a surface-based coordinate system that has advantages over conventional stereotaxic coordinates and is relevant to studies of cortical organization in humans as well as non-human primates. Together, these methods provide an improved basis for quantitative studies of individual variability in cortical organization.
Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen
2010-12-01
The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.
E-Prescribing: History, Issues, and Potentials
Salmon, J. Warren; Jiang, Ruixuan
2012-01-01
Electronic-Prescribing, Computerized Prescribing, or E-RX has increased dramatically of late in the American health care system, a long overdue alternative to the written form for the almost five billion drug treatments annually. This paper examines the history and selected issues in the rise of E-RX by a review of salient literature, interviews, and field observations in Pharmacy. Pharmacies were early adopters of computerization for a variety of factors. The profession in its new corporate forms of chain drug stores and pharmacy benefits firms has sought efficiencies, profit enhancements, and clinical improvements through managed care strategies that rely upon data automation. E-RX seems to be a leading factor in overall physician acceptance of Electronic Medical Records (EMRs), although the Centers for Medicare and Medicaid (CMS) incentives seem to be the propelling force in acceptance. We conclude that greater research should be conducted by public health professionals to focus on resolutions to pharmaceutical use, safety, and cost escalation, which persist and remain dire following health reform. PMID:23569654
Subdural abscess secondary to covert dental sepsis
Sprott, Mae S.; Hall, K.; Newman, P. K.; Welbury, R. R.; Ingham, H. R.
1981-01-01
The bacterial flora of a subdural abscess in a 17-year-old male, with radiological evidence of unilateral infection of the maxillary and frontal air sinuses, was typical of that encountered in the dental sulcus. Extensive examination revealed no primary focus of infection other than apical infection in the 2 upper first molar teeth, which were extracted. Treatment with ampicillin, gentamicin and metronidazole rapidly controlled the subdural infection, and resolution, as evidenced by computerized tomography, was complete at 10 months. PMID:7335566
ERIC Educational Resources Information Center
Lutz, John E.; And Others
The degree of success of the computerized Child-Based Information System (CBIS) was analyzed in two areas--presenting, delivering, and managing a developmental curriculum; and recording, filing, and monitoring child tracking data, including requirements for Individualized Education Plans (IEP's). Preschool handicapped and high-risk children and…
Precision-Based Item Selection for Exposure Control in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Carroll, Ian A.
2017-01-01
Item exposure control is, relative to adaptive testing, a nascent concept that has emerged only in the last two to three decades on an academic basis as a practical issue in high-stakes computerized adaptive tests. This study aims to implement a new strategy in item exposure control by incorporating the standard error of the ability estimate into…
Kim, Dong-Keun; Yoo, Sun K; Kim, Sun H
2005-01-01
The instant transmission of radiological images may be important for making rapid clinical decisions about emergency patients. We have examined an instant image transfer system based on a personal digital assistant (PDA) phone with a built-in camera. Images displayed on a picture archiving and communication systems (PACS) monitor can be captured by the camera in the PDA phone directly. Images can then be transmitted from an emergency centre to a remote physician via a wireless high-bandwidth network (CDMA 1 x EVDO). We reviewed the radiological lesions in 10 normal and 10 abnormal cases produced by modalities such as computerized tomography (CT), magnetic resonance (MR) and digital angiography. The images were of 24-bit depth and 1,144 x 880, 1,120 x 840, 1,024 x 768, 800 x 600, 640 x 480 and 320 x 240 pixels. Three neurosurgeons found that for satisfactory remote consultation a minimum size of 640 x 480 pixels was required for CT and MR images and 1,024 x 768 pixels for angiography images. Although higher resolution produced higher clinical satisfaction, it also required more transmission time. At the limited bandwidth employed, higher resolutions could not be justified.
Fisher, Joseph A
2016-06-01
Cerebrovascular reactivity (CVR) studies have elucidated the physiology and pathophysiology of cerebral blood flow regulation. A non-invasive, high spatial resolution approach uses carbon dioxide (CO2) as the vasoactive stimulus and magnetic resonance techniques to estimate the cerebral blood flow response. CVR is assessed as the ratio response change to stimulus change. Precise control of the stimulus is sought to minimize CVR variability between tests, and show functional differences. Computerized methods targeting end-tidal CO2 partial pressures are precise, but expensive. Simpler, improvised methods that fix the inspired CO2 concentrations have been recommended as less expensive, and so more widely accessible. However, these methods have drawbacks that have not been previously presented by those that advocate their use, or those that employ them in their studies. As one of the developers of a computerized method, I provide my perspective on the trade-offs between these two methods. The main concern is that declaring the precision of fixed inspired concentration of CO2 is misleading: it does not, as implied, translate to precise control of the actual vasoactive stimulus - the arterial partial pressure of CO2 The inherent test-to-test, and therefore subject-to-subject variability, precludes clinical application of findings. Moreover, improvised methods imply widespread duplication of development, assembly time and costs, yet lack uniformity and quality control. A tabular comparison between approaches is provided. © The Author(s) 2016.
ERIC Educational Resources Information Center
Goomas, David T.
2008-01-01
In this report from the field, computerized auditory feedback was used to inform order selectors and order selector auditors in a distribution center to add an electronic article surveillance (EAS) adhesive tag. This was done by programming handheld computers to emit a loud beep for high-priced items upon scanning the item's bar-coded Universal…
ERIC Educational Resources Information Center
Ho, Tsung-Han
2010-01-01
Computerized adaptive testing (CAT) provides a highly efficient alternative to the paper-and-pencil test. By selecting items that match examinees' ability levels, CAT not only can shorten test length and administration time but it can also increase measurement precision and reduce measurement error. In CAT, maximum information (MI) is the most…
Image analysis for dental bone quality assessment using CBCT imaging
NASA Astrophysics Data System (ADS)
Suprijanto; Epsilawati, L.; Hajarini, M. S.; Juliastuti, E.; Susanti, H.
2016-03-01
Cone beam computerized tomography (CBCT) is one of X-ray imaging modalities that are applied in dentistry. Its modality can visualize the oral region in 3D and in a high resolution. CBCT jaw image has potential information for the assessment of bone quality that often used for pre-operative implant planning. We propose comparison method based on normalized histogram (NH) on the region of inter-dental septum and premolar teeth. Furthermore, the NH characteristic from normal and abnormal bone condition are compared and analyzed. Four test parameters are proposed, i.e. the difference between teeth and bone average intensity (s), the ratio between bone and teeth average intensity (n) of NH, the difference between teeth and bone peak value (Δp) of NH, and the ratio between teeth and bone of NH range (r). The results showed that n, s, and Δp have potential to be the classification parameters of dental calcium density.
Method for the visualization of landform by mapping using low altitude UAV application
NASA Astrophysics Data System (ADS)
Sharan Kumar, N.; Ashraf Mohamad Ismail, Mohd; Sukor, Nur Sabahiah Abdul; Cheang, William
2018-05-01
Unmanned Aerial Vehicle (UAV) and Digital Photogrammetry are evolving drastically in mapping technology. The significance and necessity for digital landform mapping are developing with years. In this study, a mapping workflow is applied to obtain two different input data sets which are the orthophoto and DSM. A fine flying technology is used to capture Low Altitude Aerial Photography (LAAP). Low altitude UAV (Drone) with the fixed advanced camera was utilized for imagery while computerized photogrammetry handling using Photo Scan was applied for cartographic information accumulation. The data processing through photogrammetry and orthomosaic processes is the main applications. High imagery quality is essential for the effectiveness and nature of normal mapping output such as 3D model, Digital Elevation Model (DEM), Digital Surface Model (DSM) and Ortho Images. The exactitude of Ground Control Points (GCP), flight altitude and the resolution of the camera are essential for good quality DEM and Orthophoto.
Harbut, Michael R; Endress, Carmen; Graff, John J; Weis, Christopher; Pass, Harvey
2009-01-01
Taconite, although not classified by the United States Government as asbestos or asbestiform material, has been associated with asbestos-related diseases. The mineral is used in the production of steel and as a road-patch material and is mined in Michigan and Minnesota. This report describes the case of a middle-aged Caucasian woman with exposure to taconite mining dust from her miner father's clothing in childhood with a resultant presentation consistent with asbestosis and intractable pleural pain. Intractable pleural pain has been described in asbestos-exposed patients with theorized etiologies. However, no in vivo reported mechanism has demonstrated a plausible, anatomically apparent mechanism for the pain. We utilize an application of the Vitrea software for enhancement of high-resolution computerized tomography which demonstrates at least one likely mechanism for intractable pleural pain.
Learning effect of computerized cognitive tests in older adults
de Oliveira, Rafaela Sanches; Trezza, Beatriz Maria; Busse, Alexandre Leopold; Jacob-Filho, Wilson
2014-01-01
ABSTRACT Objective: To evaluate the learning effect of computerized cognitive testing in the elderly. Methods: Cross-sectional study with 20 elderly, 10 women and 10 men, with average age of 77.5 (±4.28) years. The volunteers performed two series of computerized cognitive tests in sequence and their results were compared. The applied tests were: Trail Making A and B, Spatial Recognition, Go/No Go, Memory Span, Pattern Recognition Memory and Reverse Span. Results: Based on the comparison of the results, learning effects were observed only in the Trail Making A test (p=0.019). Other tests performed presented no significant performance improvements. There was no correlation between learning effect and age (p=0.337) and education (p=0.362), as well as differences between genders (p=0.465). Conclusion: The computerized cognitive tests repeated immediately afterwards, for elderly, revealed no change in their performance, with the exception of the Trail Making test, demonstrating high clinical applicability, even in short intervals. PMID:25003917
Computerized Ultrasonic Testing System (CUTS) for in-process thickness determination
NASA Technical Reports Server (NTRS)
Frankel, J.; Doxbeck, M.; Schroeder, S. C.; Abbate, A.
1994-01-01
A Computerized Ultrasonic Testing System (CUTS) was developed to measure, in real-time, the rate of deposition and thickness of chromium plated on the inside of thick steel tubes. The measurements are made from the outside of the tubes with the ultrasonic pulse-echo technique. The resolution of the system is 2.5 micron. (0.0001 in.) and the accuracy is better than 10 micron (0.0004 in.). The thickness is measured using six transducers mounted at different locations on the tube. In addition, two transducers are mounted on two reference standards, thereby allowing the system to be continuously calibrated. The tube temperature varies during the process, thus the input from eight thermocouples, located at the measurement sites, is used to calculate and compensate for the change in return time of the ultrasonic echo due to the temperature dependence of the sound velocity. CUTS is applicable to any commercial process where real-time change of thickness of a sample has to be known, with the advantage of facilitating increased efficiency and of improving process control.
Visualizing Rhizosphere Soil Structure Around Living Roots
NASA Astrophysics Data System (ADS)
Menon, M.; Berli, M.; Ghezzehei, T. A.; Nico, P.; Young, M. H.; Tyler, S. W.
2008-12-01
The rhizosphere, a thin layer of soil (0 to 2 mm) surrounding a living root, is an important interface between bulk soil and plant root and plays a critical role in root water and nutrient uptake. In this study, we used X-ray Computerized Microtomography (microCT) to visualize soil structure around living roots non-destructively and with high spatial resolution. Four different plant species (Helianthus annuus, Lupinus hartwegii, Vigna radiata and Phaseolus lunatus), grown in four different porous materials (glass beads, medium and coarse sand, loam aggregates), were scanned with 10 ìm spatial resolution, using the microtomography beamline 8.3.2 at the Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA. Sample cross section images clearly show contacts between roots and soil particles, connecting water films, air-water interfaces as well as some cellular features of the plants taproots. We found with a simulation experiment, inflating a cylindrical micro-balloon in a pack of air-dry loam aggregates, that soil fracturing rather than compaction might occur around a taproot growing in dry soil. Form these preliminary experiments, we concluded that microCT has potential as a tool for a more process-based understanding of the role of rhizosphere soil structure on soil fertility, plant growth and the water balance at the earth-atmosphere interface.
Visualizing the impact of living roots on rhizosphere soil structure using X-ray microtomography
NASA Astrophysics Data System (ADS)
Menon, M.; Berli, M.; Ghezzehei, T. A.; Nico, P.; Young, M. H.; Tyler, S. W.
2009-04-01
The rhizosphere is an interface between bulk soil and plant root and plays a critical role in root water and nutrient uptake. In this study, we used X-ray Computerized Microtomography (microCT) to visualize soil structure around living roots non-destructively and with high spatial resolution. Four different plant species (Helianthus annuus, Lupinus hartwegii, Vigna radiata and Phaseolus lunatus), grown in four different porous materials (glass beads, medium and coarse sand, loam aggregates), were scanned with 10 μm spatial resolution, using the microtomography beamline 8.3.2 at the Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA. Sample cross section images clearly show contacts between roots and soil particles, connecting water films, air-water interfaces as well as some cellular features of the plants taproots. We found with a simulation experiment, inflating a cylindrical micro-balloon in a pack of air-dry loam aggregates, that soil fracturing rather than compaction might occur around a taproot growing in dry soil. Form these preliminary experiments, we concluded that microCT has potential as a tool for a more process-based understanding of the role of rhizosphere soil structure on soil fertility, plant growth and the water balance at the earth-atmosphere interface.
Camera calibration for multidirectional flame chemiluminescence tomography
NASA Astrophysics Data System (ADS)
Wang, Jia; Zhang, Weiguang; Zhang, Yuhong; Yu, Xun
2017-04-01
Flame chemiluminescence tomography (FCT), which combines computerized tomography theory and multidirectional chemiluminescence emission measurements, can realize instantaneous three-dimensional (3-D) diagnostics for flames with high spatial and temporal resolutions. One critical step of FCT is to record the projections by multiple cameras from different view angles. For high accuracy reconstructions, it requires that extrinsic parameters (the positions and orientations) and intrinsic parameters (especially the image distances) of cameras be accurately calibrated first. Taking the focus effect of the camera into account, a modified camera calibration method was presented for FCT, and a 3-D calibration pattern was designed to solve the parameters. The precision of the method was evaluated by reprojections of feature points to cameras with the calibration results. The maximum root mean square error of the feature points' position is 1.42 pixels and 0.0064 mm for the image distance. An FCT system with 12 cameras was calibrated by the proposed method and the 3-D CH* intensity of a propane flame was measured. The results showed that the FCT system provides reasonable reconstruction accuracy using the camera's calibration results.
Computerized analysis of sonograms for the detection of breast lesions
NASA Astrophysics Data System (ADS)
Drukker, Karen; Giger, Maryellen L.; Horsch, Karla; Vyborny, Carl J.
2002-05-01
With a renewed interest in using non-ionizing radiation for the screening of high risk women, there is a clear role for a computerized detection aid in ultrasound. Thus, we are developing a computerized detection method for the localization of lesions on breast ultrasound images. The computerized detection scheme utilizes two methods. Firstly, a radial gradient index analysis is used to distinguish potential lesions from normal parenchyma. Secondly, an image skewness analysis is performed to identify posterior acoustic shadowing. We analyzed 400 cases (757 images) consisting of complex cysts, solid benign lesions, and malignant lesions. The detection method yielded an overall sensitivity of 95% by image, and 99% by case at a false-positive rate of 0.94 per image. In 51% of all images, only the lesion itself was detected, while in 5% of the images only the shadowing was identified. For malignant lesions these numbers were 37% and 9%, respectively. In summary, we have developed a computer detection method for lesions on ultrasound images of the breast, which may ultimately aid in breast cancer screening.
Computerized Decision Aids for Shared Decision Making in Serious Illness: Systematic Review.
Staszewska, Anna; Zaki, Pearl; Lee, Joon
2017-10-06
Shared decision making (SDM) is important in achieving patient-centered care. SDM tools such as decision aids are intended to inform the patient. When used to assist in decision making between treatments, decision aids have been shown to reduce decisional conflict, increase ease of decision making, and increase modification of previous decisions. The purpose of this systematic review is to assess the impact of computerized decision aids on patient-centered outcomes related to SDM for seriously ill patients. PubMed and Scopus databases were searched to identify randomized controlled trials (RCTs) that assessed the impact of computerized decision aids on patient-centered outcomes and SDM in serious illness. Six RCTs were identified and data were extracted on study population, design, and results. Risk of bias was assessed by a modified Cochrane Risk of Bias Tool for Quality Assessment of Randomized Controlled Trials. Six RCTs tested decision tools in varying serious illnesses. Three studies compared different computerized decision aids against each other and a control. All but one study demonstrated improvement in at least one patient-centered outcome. Computerized decision tools may reduce unnecessary treatment in patients with low disease severity in comparison with informational pamphlets. Additionally, electronic health record (EHR) portals may provide the opportunity to manage care from the home for individuals affected by illness. The quality of decision aids is of great importance. Furthermore, satisfaction with the use of tools is associated with increased patient satisfaction and reduced decisional conflict. Finally, patients may benefit from computerized decision tools without the need for increased physician involvement. Most computerized decision aids improved at least one patient-centered outcome. All RCTs identified were at a High Risk of Bias or Unclear Risk of Bias. Effort should be made to improve the quality of RCTs testing SDM aids in serious illness. ©Anna Staszewska, Pearl Zaki, Joon Lee. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 06.10.2017.
Validation of a computerized algorithm to quantify fetal heart rate deceleration area.
Gyllencreutz, Erika; Lu, Ke; Lindecrantz, Kaj; Lindqvist, Pelle G; Nordstrom, Lennart; Holzmann, Malin; Abtahi, Farhad
2018-05-16
Reliability in visual cardiotocography interpretation is unsatisfying, which has led to development of computerized cardiotocography. Computerized analysis is well established for antenatal fetal surveillance, but has yet not performed sufficiently during labor. We aimed to investigate the capacity of a new computerized algorithm compared to visual assessment in identifying intrapartum fetal heart rate baseline and decelerations. Three-hundred-and-twelve intrapartum cardiotocography tracings with variable decelerations were analysed by the computerized algorithm and visually examined by two observers, blinded to each other and the computer analysis. The width, depth and area of each deceleration was measured. Four cases (>100 variable decelerations) were subject to in-depth detailed analysis. The outcome measures were bias in seconds (width), beats per minute (depth), and beats (area) between computer and observers by using Bland-Altman analysis. Interobserver reliability was determined by calculating intraclass correlation and Spearman rank analysis. The analysis (312 cases) showed excellent intraclass correlation (0.89-0.95) and very strong Spearman correlation (0.82-0.91). The detailed analysis of > 100 decelerations in 4 cases revealed low bias between the computer and the two observers; width 1.4 and 1.4 seconds, depth 5.1 and 0.7 beats per minute, and area 0.1 and -1.7 beats. This was comparable to the bias between the two observers; 0.3 seconds (width), 4.4 beats per minute (depth), and 1.7 beats (area). The intraclass correlation was excellent (0.90-0.98). A novel computerized algorithm for intrapartum cardiotocography analysis is as accurate as gold standard visual assessment with high correlation and low bias. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Reliability, validity and sensitivity of a computerized visual analog scale measuring state anxiety.
Abend, Rany; Dan, Orrie; Maoz, Keren; Raz, Sivan; Bar-Haim, Yair
2014-12-01
Assessment of state anxiety is frequently required in clinical and research settings, but its measurement using standard multi-item inventories entails practical challenges. Such inventories are increasingly complemented by paper-and-pencil, single-item visual analog scales measuring state anxiety (VAS-A), which allow rapid assessment of current anxiety states. Computerized versions of VAS-A offer additional advantages, including facilitated and accurate data collection and analysis, and applicability to computer-based protocols. Here, we establish the psychometric properties of a computerized VAS-A. Experiment 1 assessed the reliability, convergent validity, and discriminant validity of the computerized VAS-A in a non-selected sample. Experiment 2 assessed its sensitivity to increase in state anxiety following social stress induction, in participants with high levels of social anxiety. Experiment 1 demonstrated the computerized VAS-A's test-retest reliability (r = .44, p < .001); convergent validity with the State-Trait Anxiety Inventory's state subscale (STAI-State; r = .60, p < .001); and discriminant validity as indicated by significantly lower correlations between VAS-A and different psychological measures relative to the correlation between VAS-A and STAI-State. Experiment 2 demonstrated the VAS-A's sensitivity to changes in state anxiety via a significant pre- to during-stressor rise in VAS-A scores (F(1,48) = 25.13, p < .001). Set-order administration of measures, absence of clinically-anxious population, and gender-unbalanced samples. The adequate psychometric characteristics, combined with simple and rapid administration, make the computerized VAS-A a valuable self-rating tool for state anxiety. It may prove particularly useful for clinical and research settings where multi-item inventories are less applicable, including computer-based treatment and assessment protocols. The VAS-A is freely available: http://people.socsci.tau.ac.il/mu/anxietytrauma/visual-analog-scale/. Copyright © 2014 Elsevier Ltd. All rights reserved.
Goldstein, Lizabeth A; Connolly Gibbons, Mary Beth; Thompson, Sarah M; Scott, Kelli; Heintz, Laura; Green, Patricia; Thompson, Donald; Crits-Christoph, Paul
2011-07-01
Computerized administration of mental health-related questionnaires has become relatively common, but little research has explored this mode of assessment in "real-world" settings. In the current study, 200 consumers at a community mental health center completed the BASIS-24 via handheld computer as well as paper and pen. Scores on the computerized BASIS-24 were compared with scores on the paper BASIS-24. Consumers also completed a questionnaire which assessed their level of satisfaction with the computerized BASIS-24. Results indicated that the BASIS-24 administered via handheld computer was highly correlated with pen and paper administration of the measure and was generally acceptable to consumers. Administration of the BASIS-24 via handheld computer may allow for efficient and sustainable outcomes assessment, adaptable research infrastructure, and maximization of clinical impact in community mental health agencies.
[Complex automatic data processing in multi-profile hospitals].
Dovzhenko, Iu M; Panov, G D
1990-01-01
The computerization of data processing in multi-disciplinary hospitals is the key factor in raising the quality of medical care provided to the population, intensifying the work of the personnel, improving the curative and diagnostic process and the use of resources. Even a small experience in complex computerization at the Botkin Hospital indicates that due to the use of the automated system the quality of data processing in being improved, a high level of patients' examination is being provided, a speedy training of young specialists is being achieved, conditions are being created for continuing education of physicians through the analysis of their own activity. At big hospitals a complex solution of administrative and curative diagnostic tasks on the basis of general hospital network of display connection and general hospital data bank is the most prospective form of computerization.
11 CFR 9033.12 - Production of computerized information.
Code of Federal Regulations, 2011 CFR
2011-01-01
... magnetic media, such as magnetic tapes or magnetic diskettes, containing the computerized information at.... The computerized magnetic media shall be prepared and delivered at the committee's expense and shall... Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal...
Calvopina, Manuel; Romero-Alvarez, Daniel; Macias, Rubén; Sugiyama, Hiromu
2017-01-11
A 30-year-old male, from a subtropical region of Ecuador, was hospitalized with a 5-year history of persistent cough with rusty brown sputum, chest pain, and progressive dyspnea. The patient underwent thoracic surgery 3 years ago for pleural effusion and subsequently received a 9-month regimen treatment of tuberculosis. However, there was no clinical resolution and symptoms became progressively worse. A chest radiograph and computerized tomography scan showed several small nodules in both lungs. Eggs of Paragonimus spp. were observed in sputum smears, but the smears were negative for acid-fast bacilli. Molecular characterization of eggs by the internal transcribed spacer-2 regions identified them as Paragonimus mexicanus The patient was treated with praziquantel and tested negative parasitologically for 12 months. There was clinical resolution of the cough and expectoration, but dyspnea and chest pain persisted. © The American Society of Tropical Medicine and Hygiene.
Calvopina, Manuel; Romero-Alvarez, Daniel; Macias, Rubén; Sugiyama, Hiromu
2017-01-01
A 30-year-old male, from a subtropical region of Ecuador, was hospitalized with a 5-year history of persistent cough with rusty brown sputum, chest pain, and progressive dyspnea. The patient underwent thoracic surgery 3 years ago for pleural effusion and subsequently received a 9-month regimen treatment of tuberculosis. However, there was no clinical resolution and symptoms became progressively worse. A chest radiograph and computerized tomography scan showed several small nodules in both lungs. Eggs of Paragonimus spp. were observed in sputum smears, but the smears were negative for acid-fast bacilli. Molecular characterization of eggs by the internal transcribed spacer-2 regions identified them as Paragonimus mexicanus. The patient was treated with praziquantel and tested negative parasitologically for 12 months. There was clinical resolution of the cough and expectoration, but dyspnea and chest pain persisted. PMID:27879464
Dispositional anger and the resolution of the approach-avoidance conflict.
Robinson, Michael D; Boyd, Ryan L; Persich, Michelle R
2016-09-01
The approach-avoidance conflict is one in which approaching reward brings increased threat while avoiding threat means forgoing reward. This conflict can be uniquely informative because it will be resolved in different ways depending on whether approach (toward) or avoidance (away from) is the stronger motive. Two studies (total N = 191) created a computerized version of this conflict and used the test to examine questions of motivational direction in anger. In Study 1, noise blast provocations increased the frequency of approach behaviors at high levels of trait anger, but decreased their frequency at low levels. In Study 2, a simpler version of the conflict test was used to predict anger in daily life. As hypothesized, greater approach frequencies in the test predicted greater anger reactivity to daily provocations and frustrations. The discussion focuses on the utility of the approach-avoidance conflict test and on questions of motivational direction in anger. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Hsiao, Ju-Ling; Chen, Rai-Fu
2016-01-16
With the widespread use of information communication technologies, computerized clinical practice guidelines are developed and considered as effective decision supporting tools in assisting the processes of clinical activities. However, the development of computerized clinical practice guidelines in Taiwan is still at the early stage and acceptance level among major users (physicians) of computerized clinical practice guidelines is not satisfactory. This study aims to investigate critical factors influencing physicians' intention to computerized clinical practice guideline use through an integrative model of activity theory and the technology acceptance model. The survey methodology was employed to collect data from physicians of the investigated hospitals that have implemented computerized clinical practice guidelines. A total of 505 questionnaires were sent out, with 238 completed copies returned, indicating a valid response rate of 47.1 %. The collected data was then analyzed by structural equation modeling technique. The results showed that attitudes toward using computerized clinical practice guidelines (γ = 0.451, p < 0.001), organizational support (γ = 0.285, p < 0.001), perceived usefulness of computerized clinical practice guidelines (γ = 0.219, p < 0.05), and social influence (γ = 0.213, p < 0.05) were critical factors influencing physicians' intention to use computerized clinical practice guidelines, and these factors can explain 68.6 % of the variance in intention to use computerized clinical practice guidelines. This study confirmed that some subject (human) factors, environment (organization) factors, tool (technology) factors mentioned in the activity theory should be carefully considered when introducing computerized clinical practice guidelines. Managers should pay much attention on those identified factors and provide adequate resources and incentives to help the promotion and use of computerized clinical practice guidelines. Through the appropriate use of computerized clinical practice guidelines, the clinical benefits, particularly in improving quality of care and facilitating the clinical processes, will be realized.
39 CFR 501.15 - Computerized Meter Resetting System.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15...
Preliminary evaluation of a micro-based repeated measures testing system
NASA Technical Reports Server (NTRS)
Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.
1985-01-01
A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.
O'Neill, Marisol; Huang, Gene O; Lamb, Dolores J
2017-12-01
The murine penis model has enriched our understanding of anomalous penile development. The morphologic characterization of the murine penis using conventional serial sectioning methods is labor intensive and prone to errors. To develop a novel application of micro-computerized tomography (micro-CT) with iodine staining for rapid, non-destructive morphologic study of murine penis structure. Penises were dissected from 10 adult wild-type mice and imaged using micro-CT with iodine staining. Images were acquired at 5-μm spatial resolution on a Bruker SkyScan 1272 micro-CT system. After images were acquired, the specimens were washed of any remaining iodine and embedded in paraffin for conventional histologic examination. Histologic and micro-CT measurements for all specimens were made by 2 independent observers. Measurements of penile structures were made on virtual micro-CT sections and histologic slides. The Lin concordance correlation coefficient demonstrated almost perfect strength of agreement for interobserver variability for histologic section (0.9995, 95% CI = 0.9990-0.9997) and micro-CT section (0.9982, 95% CI = 0.9963-0.9991) measurements. Bland-Altman analysis for agreement between the 2 modalities of measurement demonstrated mean differences of -0.029, 0.022, and -0.068 mm for male urogenital mating protuberance, baculum, and penile glans length, respectively. There did not appear to be a bias for overestimation or underestimation of measured lengths and limits of agreement were narrow. The enhanced ability offered by micro-CT to phenotype the murine penis has the potential to improve translational studies examining the molecular pathways contributing to anomalous penile development. The present study describes the first reported use of micro-CT with iodine staining for imaging the murine penis. Producing repeated histologic sections of identical orientation was limited by inherent imperfections in mounting and tissue sectioning, but this was compensated for by using micro-CT reconstructions to identify matching virtual sections. This study demonstrates the successful use of micro-CT with iodine staining, which has the potential for submicron spatial resolution, as a non-destructive method of characterizing murine penile morphology. O'Neill M, Huang GO, Lamb DJ. Novel Application of Micro-Computerized Tomography for Morphologic Characterization of the Murine Penis. J Sex Med 2017;14:1533-1539. Copyright © 2017. Published by Elsevier Inc.
Wang, Lin-Wei; Qu, Ai-Ping; Liu, Wen-Lou; Chen, Jia-Mei; Yuan, Jing-Ping; Wu, Han; Li, Yan; Liu, Juan
2016-02-03
As a widely used proliferative marker, Ki67 has important impacts on cancer prognosis, especially for breast cancer (BC). However, variations in analytical practice make it difficult for pathologists to manually measure Ki67 index. This study is to establish quantum dots (QDs)-based double imaging of nuclear Ki67 as red signal by QDs-655, cytoplasmic cytokeratin (CK) as yellow signal by QDs-585, and organic dye imaging of cell nucleus as blue signal by 4',6-diamidino-2-phenylindole (DAPI), and to develop a computer-aided automatic method for Ki67 index measurement. The newly developed automatic computerized Ki67 measurement could efficiently recognize and count Ki67-positive cancer cell nuclei with red signals and cancer cell nuclei with blue signals within cancer cell cytoplasmic with yellow signals. Comparisons of computerized Ki67 index, visual Ki67 index, and marked Ki67 index for 30 patients of 90 images with Ki67 ≤ 10% (low grade), 10% < Ki67 < 50% (moderate grade), and Ki67 ≥ 50% (high grade) showed computerized Ki67 counting is better than visual Ki67 counting, especially for Ki67 low and moderate grades. Based on QDs-based double imaging and organic dye imaging on BC tissues, this study successfully developed an automatic computerized Ki67 counting method to measure Ki67 index.
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...
Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.
Segars, W Paul; Tsui, B M W; Cai, Jing; Yin, Fang-Fang; Fung, George S K; Samei, Ehsan
2018-03-01
The four-dimensional (4-D) eXtended CArdiac-Torso (XCAT) series of phantoms was developed to provide accurate computerized models of the human anatomy and physiology. The XCAT series encompasses a vast population of phantoms of varying ages from newborn to adult, each including parameterized models for the cardiac and respiratory motions. With great flexibility in the XCAT's design, any number of body sizes, different anatomies, cardiac or respiratory motions or patterns, patient positions and orientations, and spatial resolutions can be simulated. As such, the XCAT phantoms are gaining a wide use in biomedical imaging research. There they can provide a virtual patient base from which to quantitatively evaluate and improve imaging instrumentation, data acquisition, techniques, and image reconstruction and processing methods which can lead to improved image quality and more accurate clinical diagnoses. The phantoms have also found great use in radiation dosimetry, radiation therapy, medical device design, and even the security and defense industry. This review paper highlights some specific areas in which the XCAT phantoms have found use within biomedical imaging and other fields. From these examples, we illustrate the increasingly important role that computerized phantoms and computer simulation are playing in the research community.
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... computerized support enforcement systems. 307.15 Section 307.15 Public Welfare Regulations Relating to Public... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.15 Approval of advance planning documents for computerized support enforcement systems. (a...
Arkansas' Curriculum Guide. Competency Based Computerized Accounting.
ERIC Educational Resources Information Center
Arkansas State Dept. of Education, Little Rock. Div. of Vocational, Technical and Adult Education.
This guide contains the essential parts of a total curriculum for a one-year secondary-level course in computerized accounting. Addressed in the individual sections of the guide are the following topics: the complete accounting cycle, computer operations for accounting, computerized accounting and general ledgers, computerized accounts payable,…
Nelson, Lindsay D; LaRoche, Ashley A; Pfaller, Adam Y; Lerner, E Brooke; Hammeke, Thomas A; Randolph, Christopher; Barr, William B; Guskiewicz, Kevin; McCrea, Michael A
2016-01-01
Limited data exist comparing the performance of computerized neurocognitive tests (CNTs) for assessing sport-related concussion. We evaluated the reliability and validity of three CNTs-ANAM, Axon Sports/Cogstate Sport, and ImPACT-in a common sample. High school and collegiate athletes completed two CNTs each at baseline. Concussed (n=165) and matched non-injured control (n=166) subjects repeated testing within 24 hr and at 8, 15, and 45 days post-injury. Roughly a quarter of each CNT's indices had stability coefficients (M=198 day interval) over .70. Group differences in performance were mostly moderate to large at 24 hr and small by day 8. The sensitivity of reliable change indices (RCIs) was best at 24 hr (67.8%, 60.3%, and 47.6% with one or more significant RCIs for ImPACT, Axon, and ANAM, respectively) but diminished to near the false positive rates thereafter. Across time, the CNTs' sensitivities were highest in those athletes who became asymptomatic within 1 day before neurocognitive testing but was similar to the tests' false positive rates when including athletes who became asymptomatic several days earlier. Test-retest reliability was similar among these three CNTs and below optimal standards for clinical use on many subtests. Analyses of group effect sizes, discrimination, and sensitivity and specificity suggested that the CNTs may add incrementally (beyond symptom scores) to the identification of clinical impairment within 24 hr of injury or within a short time period after symptom resolution but do not add significant value over symptom assessment later. The rapid clinical recovery course from concussion and modest stability probably jointly contribute to limited signal detection capabilities of neurocognitive tests outside a brief post-injury window. (JINS, 2016, 22, 24-37).
Nelson, Lindsay D.; LaRoche, Ashley A.; Pfaller, Adam Y.; Lerner, E. Brooke; Hammeke, Thomas A.; Randolph, Christopher; Barr, William B.; Guskiewicz, Kevin; McCrea, Michael A.
2016-01-01
Limited data exist comparing the performance of computerized neurocognitive tests (CNTs) for assessing sport-related concussion. We evaluated the reliability and validity of three CNTs—ANAM, Axon Sports/Cogstate Sport, and ImPACT—in a common sample. High school and collegiate athletes completed two CNTs each at baseline. Concussed (n = 165) and matched non-injured control (n = 166) subjects repeated testing within 24 hr and at 8, 15, and 45 days post-injury. Roughly a quarter of each CNT's indices had stability coefficients (M = 198 day interval) over .70. Group differences in performance were mostly moderate to large at 24 hr and small by day 8. The sensitivity of reliable change indices (RCIs) was best at 24 hr (67.8%, 60.3%, and 47.6% with one or more significant RCIs for ImPACT, Axon, and ANAM, respectively) but diminished to near the false positive rates thereafter. Across time, the CNTs' sensitivities were highest in those athletes who became asymptomatic within 1 day before neurocognitive testing but was similar to the tests' false positive rates when including athletes who became asymptomatic several days earlier. Test–retest reliability was similar among these three CNTs and below optimal standards for clinical use on many subtests. Analyses of group effect sizes, discrimination, and sensitivity and specificity suggested that the CNTs may add incrementally (beyond symptom scores) to the identification of clinical impairment within 24 hr of injury or within a short time period after symptom resolution but do not add significant value over symptom assessment later. The rapid clinical recovery course from concussion and modest stability probably jointly contribute to limited signal detection capabilities of neurocognitive tests outside a brief post-injury window. PMID:26714883
Computerized detection of leukocytes in microscopic leukorrhea images.
Zhang, Jing; Zhong, Ya; Wang, Xiangzhou; Ni, Guangming; Du, Xiaohui; Liu, Juanxiu; Liu, Lin; Liu, Yong
2017-09-01
Detection of leukocytes is critical for the routine leukorrhea exam, which is widely used in gynecological examinations. An elevated vaginal leukocyte count in women with bacterial vaginosis is a strong predictor of vaginal or cervical infections. In the routine leukorrhea exam, the counting of leukocytes is primarily performed by manual techniques. However, the viewing and counting of leukocytes from multiple high-power viewing fields on a glass slide under a microscope leads to subjectivity, low efficiency, and low accuracy. To date, many biological cells in stool, blood, and breast cancer have been studied to realize computerized detection; however, the detection of leukocytes in microscopic leukorrhea images has not been studied. Thus, there is an increasing need for computerized detection of leukocytes. There are two key processes in the computerized detection of leukocytes in digital image processing. One is segmentation; the other is intelligent classification. In this paper, we propose a combined ensemble to detect leukocytes in the microscopic leukorrhea image. After image segmentation and selecting likely leukocyte subimages, we obtain the leukocyte candidates. Then, for intelligent classification, we adopt two methods: feature extraction and classification by a support vector machine (SVM); applying a modified convolutional neural network (CNN) to the larger subimages. If different methods classify a candidate in the same category, the process is finished. If not, the outputs of the methods are provided to a classifier to further classify the candidate. After acquiring leukocyte candidates, we attempted three methods to perform classification. The first approach using features and SVM achieved 88% sensitivity, 97% specificity, and 92.5% accuracy. The second method using CNN achieved 95% sensitivity, 84% specificity, and 89.5% accuracy. Then, in the combination approach, we achieved 92% sensitivity, 95% specificity, and 93.5% accuracy. Finally, the images with marked and counted leukocytes were obtained. A novel computerized detection system was developed for automated detection of leukocytes in microscopic images. Different methods resulted in comparable overall qualities by enabling computerized detection of leukocytes. The proposed approach further improved the performance. This preliminary study proves the feasibility of computerized detection of leukocytes in clinical use. © 2017 American Association of Physicists in Medicine.
ERIC Educational Resources Information Center
Forbey, Johnathan D.; Ben-Porath, Yossef S.
2007-01-01
Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…
A Randomized Controlled Trial of the "Cool Teens" CD-ROM Computerized Program for Adolescent Anxiety
ERIC Educational Resources Information Center
Wuthrich, Viviana M.; Rapee, Ronald M.; Cunningham, Michael J.; Lyneham, Heidi J.; Hudson, Jennifer L.; Schniering, Carolyn A.
2012-01-01
Objective: Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This…
Sacks, Stephanie; Fisher, Melissa; Garrett, Coleman; Alexander, Phillip; Holland, Christine; Rose, Demian; Hooker, Christine; Vinogradov, Sophia
2013-01-01
Social cognitive deficits are an important treatment target in schizophrenia, but it is unclear to what degree they require specialized interventions and which specific components of behavioral interventions are effective. In this pilot study, we explored the effects of a novel computerized neuroplasticity-based auditory training delivered in conjunction with computerized social cognition training (SCT) in patients with schizophrenia. Nineteen clinically stable schizophrenia subjects performed 50 hours of computerized exercises that place implicit, increasing demands on auditory perception, plus 12 hours of computerized training in emotion identification, social perception, and theory of mind tasks. All subjects were assessed with MATRICS-recommended measures of neurocognition and social cognition, plus a measure of self-referential source memory before and after the computerized training. Subjects showed significant improvements on multiple measures of neurocognition. Additionally, subjects showed significant gains on measures of social cognition, including the MSCEIT Perceiving Emotions, MSCEIT Managing Emotions, and self-referential source memory, plus a significant decrease in positive symptoms. Computerized training of auditory processing/verbal learning in schizophrenia results in significant basic neurocognitive gains. Further, addition of computerized social cognition training results in significant gains in several social cognitive outcome measures. Computerized cognitive training that directly targets social cognitive processes can drive improvements in these crucial functions.
Wong, Sui To; Yuen, Ming Keung; Fok, Kam Fuk; Yuen, Shing Chau; Yam, Kwong Yui; Fong, Dawson
2009-01-01
Rapid spontaneous resolution of posttraumatic intracranial ASDH has been reported in the literature since 1986. We report a case to demonstrate that redistribution of hematoma to the spinal subdural space is a mechanism for the rapid spontaneous resolution of posttraumatic intracranial ASDH. A 73-year-old woman with a slipped-and-fell injury had a worst GCS score of 8/15. Computerized tomography of the brain demonstrated a large intracranial ASDH with mass effect. Conservative management was decided because of her poor premorbid general condition. Rapid clinical improvement was observed within 5 hours after the CT. Progress CT of the brain at 45 hours postinjury showed that the size of the intracranial ASDH was markedly diminished. The CT findings apparently demonstrated a caudal distribution of the intracranial ASDH over the tentorium and then into the posterior fossa. To investigate this further, an MRI of the spine was performed, which showed that there was spinal SDH in the cervical and thoracic spine. This is the first report demonstrating that redistribution of posttraumatic intracranial ASDH to the spinal subdural space is one of the mechanisms behind the rapid spontaneous resolution of posttraumatic intracranial ASDH in the acute phase.
Bombesin receptors and transplanted stem cells in rat brain: High-resolution scan with 99mTc BN1.1
NASA Astrophysics Data System (ADS)
Scopinaro, F.; Paschali, E.; Di Santo, G.; Antonellis, T.; Massari, R.; Trotta, C.; Gourni, H.; Bouziotis, P.; David, V.; Soluri, A.; Varvarigou, A. D.
2006-12-01
The aim of this work is to detect the presence of transplanted stem cells (TSC) in rat brain with high-resolution (HR) scintigraphy and labelled bombesin (BN). BN is a morphogen for Central Nervous System (CNS) as well as for other organs: CNS-oriented TSC over-express BN Receptors (BNR). BN is also a neurotransmitter and modulates several functions of CNS. 99mTc labelled BN-like peptide scan of CNS is the ideal method to detect growing TSC once knowing normal distribution of BNRs in CNS. HR Planar and single photon emission computerized tomography (SPECT) images of rat brain were performed with new HR detectors (Li-tech, Italy). Pertechnetate, 99mTc HMPAO and the new 99mTc BN1.1 (patented) were i.v. administered in five rats. HR SPECT of 99mTc BN1.1 detected olfactory tract, fronto-lateral cortex, cerebellum, basal ganglia and amygdale. Results of SPECT were confirmed by bio-distribution study performed after autopsy of three of the five rats. The remaining two rats underwent cerebral lesions followed by transplant of TSC. Three months later, HR scintigraphy was repeated and showed images completely different from previous basal study, with hot spot of 99mTc BN1.1 corresponding to the site of TSC transplant. Immuno-histochemistry confirmed the presence of viable TSC. Not only 99mTc BN1.1 HR scan showed viability of transplanted TSC but also the "background brain" was the still now unknown map of BNR in mammalian brain.
Code of Federal Regulations, 2010 CFR
2010-10-01
... records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for... monitoring Computerized Tribal IV-D Systems and Office Automation? In accordance with Part 95 of this title...
Comparative study of smile analysis by subjective and computerized methods.
Basting, Roberta Tarkany; da Trindade, Rita de Cássia Silva; Flório, Flávia Martão
2006-01-01
This study compared: 1) the subjective analyses of a smile done by specialists with advanced training and by general dentists; 2) the subjective analysis of a smile, or that associated with the face, by specialists with advanced training and general dentists; 3) subjective analysis using a computerized analysis of the smile by specialists with advanced training, verifying the midline, labial line, smile line, the line between commissures and the golden proportion. The sample consisted of 100 adults with natural dentition; 200 photographs were taken (100 of the smile and 100 of the entire face). Computerized analysis using AutoCAD software was performed, together with the subjective analyses of 2 groups of professionals (3 general dentists and 3 specialists with advanced training), using the following assessment factors: the midline, labial line, smile line, line between the commissures and the golden proportion. The smile itself and the smile associated with the entire face were recorded as being agreeable or not agreeable by the professionals. The McNemar test showed a highly significant difference (p=0.0000) among the subjective analyses performed by specialists compared to general dentists. Between the 2 groups of dental professionals, there were highly significant differences (p=0.0000) found between the subjective analyses of the smile and that of the face. The McNemar test showed statistical differences in all factors assessed, with the exception of the midline (p=0.1951), when the computerized analysis and subjective analysis of the specialists were compared. In order to establish harmony of the smile, it was not possible to establish a greater or lesser relevance among the factors analyzed.
Dennett, Amy M; Taylor, Nicholas F
2015-01-01
To determine the effectiveness of computer-based electronic devices that provide feedback in improving mobility and balance and reducing falls. Randomized controlled trials were searched from the earliest available date to August 2013. Standardized mean differences were used to complete meta-analyses, with statistical heterogeneity being described with the I-squared statistic. The GRADE approach was used to summarize the level of evidence for each completed meta-analysis. Risk of bias for individual trials was assessed with the (Physiotherapy Evidence Database) PEDro scale. Thirty trials were included. There was high-quality evidence that computerized devices can improve dynamic balance in people with a neurological condition compared with no therapy. There was low-to-moderate-quality evidence that computerized devices have no significant effect on mobility, falls efficacy and falls risk in community-dwelling older adults, and people with a neurological condition compared with physiotherapy. There is high-quality evidence that computerized devices that provide feedback may be useful in improving balance in people with neurological conditions compared with no therapy, but there is a lack of evidence supporting more meaningful changes in mobility and falls risk.
NASA Technical Reports Server (NTRS)
Kennedy, Robert S.; Jones, Marshall B.; Baltzley, Dennis R.
1988-01-01
A major application of isoperformance is as a trade-off methodology of the three major drivers of system design; equipment, training variables, and user characteristics. The flexibility of isoperformance allows each of these three components to be nearly any rational variation. For example, aptitude may be military Armed Forces Qualification Testing (AFQT) categories, cutoff scores within a selection procedure, or simply dichotomizing high and low scorers (pass/fail). Equipment may be new versus old, 'smart' versus dumb, high versus low resolution, etc. Training may be short versus long or varieties of media types (lecture versus CAI/CBI versus self-paced workbooks). In its final computerized form isoperformance lets the user set an operational level of performance (e.g., a jet pilot in a simulated emergency must take prescribed corrective action and clear the plane in several seconds, pilot astronauts will check out all shuttle flight systems within 30 minutes, or Mission Specialists must handle sucdessfully a required number of job elements). At this point the computer program guides the user through any requested trade-offs of the three components while maintaining the specified operational level of performance through isoperformance curves. A demonstration of the computer program is currently available.
New data processing for multichannel FIR laser interferometer
NASA Astrophysics Data System (ADS)
Jun-Ben, Chen; Xiang, Gao
1989-10-01
Usually, both the probing and reference signals received by LATGS detectors of FIR interferometer pass through hardware phase discriminator and the output phase difference--hence the electron line densities is collected for analysis and display with a computerized data acquisition system(DAS). In this paper, a new numerical method for computing the phase difference in software has been developed instead of hardware phase discriminator, the temporal resolution and stability is improved. An asymmetrical Abel inversion is applied to processing the data from a seven-channel FIR HCN laser interferometer and the space-time distributions of plasma electron density in the HT-6M tokamak are derived.
Analysis of pressure-flow data in terms of computer-derived urethral resistance parameters.
van Mastrigt, R; Kranse, M
1995-01-01
The simultaneous measurement of detrusor pressure and flow rate during voiding is at present the only way to measure or grade infravesical obstruction objectively. Numerous methods have been introduced to analyze the resulting data. These methods differ in aim (measurement of urethral resistance and/or diagnosis of obstruction), method (manual versus computerized data processing), theory or model used, and resolution (continuously variable parameters or a limited number of classes, the so-called monogram). In this paper, some aspects of these fundamental differences are discussed and illustrated. Subsequently, the properties and clinical performance of two computer-based methods for deriving continuous urethral resistance parameters are treated.
Zheng, Kai; Fear, Kathleen; Chaffee, Bruce W; Zimmerman, Christopher R; Karls, Edward M; Gatwood, Justin D; Stevenson, James G; Pearlman, Mark D
2011-12-01
To develop a theoretically informed and empirically validated survey instrument for assessing prescribers' perception of computerized drug-drug interaction (DDI) alerts. The survey is grounded in the unified theory of acceptance and use of technology and an adapted accident causation model. Development of the instrument was also informed by a review of the extant literature on prescribers' attitude toward computerized medication safety alerts and common prescriber-provided reasons for overriding. To refine and validate the survey, we conducted a two-stage empirical validation study consisting of a pretest with a panel of domain experts followed by a field test among all eligible prescribers at our institution. The resulting survey instrument contains 28 questionnaire items assessing six theoretical dimensions: performance expectancy, effort expectancy, social influence, facilitating conditions, perceived fatigue, and perceived use behavior. Satisfactory results were obtained from the field validation; however, a few potential issues were also identified. We analyzed these issues accordingly and the results led to the final survey instrument as well as usage recommendations. High override rates of computerized medication safety alerts have been a prevalent problem. They are usually caused by, or manifested in, issues of poor end user acceptance. However, standardized research tools for assessing and understanding end users' perception are currently lacking, which inhibits knowledge accumulation and consequently forgoes improvement opportunities. The survey instrument presented in this paper may help fill this methodological gap. We developed and empirically validated a survey instrument that may be useful for future research on DDI alerts and other types of computerized medication safety alerts more generally.
Chaple, Michael; Sacks, Stanley; McKendrick, Karen; Marsch, Lisa A; Belenko, Steven; Leukefeld, Carl; Prendergast, Michael; French, Michael
2014-01-01
Despite evidence that treatment is effective in reducing recidivism among inmates with substance use problems, scarce resources mean that few of those in need of treatment actually receive it. Computerized substance abuse interventions could be used to expand access to treatment in prisons without placing an undue burden on resources. The major aim of the study was to compare treatment conditions in terms of their service utilization, skills acquisition, and treatment satisfaction. The study recruited men and women with substance use disorders from 10 prisons in 4 states. In an open label clinical trial, 494 subjects were randomly assigned either to the Experimental condition, a computerized drug treatment intervention, the Therapeutic Education System (TES; n = 249), or to the Control condition, Standard Care ( n = 245). Chi-square tests compared groups on categorical variables and independent samples t tests were used for interval level continuous variables. Initial evidence demonstrated: (1) comparable group rates of session attendance and high rates of TES module completion for experimental subjects; (2) comparable group gains in the development of coping skills; and (3) a more favorable view of TES than of Standard Care . Collectively, these results show that a computerized intervention, such as TES, can be implemented successfully in prison. Given the barriers to the delivery of substance abuse treatment typically encountered in correctional settings, computerized interventions have the potential to fill a significant treatment gap and are particularly well suited to inmates with mild to moderate substance use disorders who often are not treated.
Douglass, John K; Wehling, Martin F
2016-12-01
A highly automated goniometer instrument (called FACETS) has been developed to facilitate rapid mapping of compound eye parameters for investigating regional visual field specializations. The instrument demonstrates the feasibility of analyzing the complete field of view of an insect eye in a fraction of the time required if using non-motorized, non-computerized methods. Faster eye mapping makes it practical for the first time to employ sample sizes appropriate for testing hypotheses about the visual significance of interspecific differences in regional specializations. Example maps of facet sizes are presented from four dipteran insects representing the Asilidae, Calliphoridae, and Stratiomyidae. These maps provide the first quantitative documentation of the frontal enlarged-facet zones (EFZs) that typify asilid eyes, which, together with the EFZs in male Calliphoridae, are likely to be correlated with high-spatial-resolution acute zones. The presence of EFZs contrasts sharply with the almost homogeneous distribution of facet sizes in the stratiomyid. Moreover, the shapes of EFZs differ among species, suggesting functional specializations that may reflect differences in visual ecology. Surveys of this nature can help identify species that should be targeted for additional studies, which will elucidate fundamental principles and constraints that govern visual field specializations and their evolution.
Properties of an ideal PET perfusion tracer: new PET tracer cases and data.
Maddahi, Jamshid
2012-02-01
An ideal positron emission tomography (PET) tracer should be highly extractable by the myocardium and able to provide high-resolution images, should enable quantification of absolute myocardial blood flow (MBF), should be compatible with both pharmacologically induced and exercise-induced stress imaging, and should not require an on-site cyclotron. The PET radionuclides nitrogen-13 ammonia and oxygen-15 water require an on-site cyclotron. Rubidium-82 may be available locally due to the generator source, but greater utilization is limited because of its relatively low myocardial extraction fraction, long positron range, and generator cost. Flurpiridaz F 18, a novel PET tracer in development, has a high-extraction fraction, short positron range, and relatively long half-life (as compared to currently available tracers), and may be produced at regional cyclotrons. Results of early clinical trials suggest that both pharmacologically and exercise-induced stress PET imaging protocols can be completed more rapidly and with lower patient radiation exposure than with single-photon emission computerized tomography (SPECT) tracers. As compared to SPECT images in the same patients, flurpiridaz F 18 PET images showed better defect contrast. Flurpiridaz F 18 is a potentially promising tracer for assessment of myocardial perfusion, measurement of absolute MBF, calculation of coronary flow reserves, and assessment of cardiac function at the peak of the stress response.
Computerized adaptive control weld skate with CCTV weld guidance project
NASA Technical Reports Server (NTRS)
Wall, W. A.
1976-01-01
This report summarizes progress of the automatic computerized weld skate development portion of the Computerized Weld Skate with Closed Circuit Television (CCTV) Arc Guidance Project. The main goal of the project is to develop an automatic welding skate demonstration model equipped with CCTV weld guidance. The three main goals of the overall project are to: (1) develop a demonstration model computerized weld skate system, (2) develop a demonstration model automatic CCTV guidance system, and (3) integrate the two systems into a demonstration model of computerized weld skate with CCTV weld guidance for welding contoured parts.
NASA Technical Reports Server (NTRS)
1985-01-01
"Elizabeth," a computerized beauty analysis system marketed by Elizabeth Arden, is based upon an ARAC data base search of technologies measuring skin profiles. * "Elizabeth" is no longer commercially available.
An Application of Computerized Axial Tomography (CAT) Technology to Mass Raid Tracking
1989-08-01
ESD-TR-89-305 MTR-10542 An Application of Computerized Axial Tomography ( CAT ) Technology to Mass Raid Tracking By John K. Barr August 1989...NO 11. TITLE (Include Security Classification) An Application of Computerized Axial Tomography ( CAT ) Technology to Mass Raid Tracking 12...by block number) Computerized Axial Tomography ( CAT ) Scanner Electronic Support Measures (ESM) Fusion (continued) 19. ABSTRACT (Continue on
Increasing profitability through computerization.
Sokol, D J
1988-01-01
The author explores the pragmatic or financial justification for computerizing a dental practice and discusses a computerized approach to precollection and collection for the dental office. The article also deals with the use of computerized correspondence to augment the recall policy of the office and to help generate new patient referrals and discusses the pros and cons of utilizing a dental computer service bureau in implementing these policies.
Computerized tomography in neuro-ophthalmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moseley, I.F.; Sanders, M.D.
This highly specialized text is organized into sections that cover anatomy, diseases of the orbit, visual loss, optic nerve disease, disorders of eye movement, and heredofamilial, developmental, and metabolic disorders.
McCarthy, Jillian H; Hogan, Tiffany P; Beukelman, David R; Schwarz, Ilsa E
2015-05-01
Spelling is an important skill for individuals who rely on augmentative and alternative communication (AAC). The purpose of this study was to investigate how computerized sounding out influenced spelling accuracy of pseudo-words. Computerized sounding out was defined as a word elongated, thus providing an opportunity for a child to hear all the sounds in the word at a slower rate. Seven children with cerebral palsy, four who use AAC and three who do not, participated in a single subject AB design. The results of the study indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words produced by participants. The study provides preliminary evidence for the use of computerized sounding out during spelling tasks for children with cerebral palsy who do and do not use AAC. Future directions and clinical implications are discussed. We investigated how computerized sounding out influenced spelling accuracy of pseudowords for children with complex communication needs who did and did not use augmentative and alternative communication (AAC). Results indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words by participants, suggesting that computerized sounding out might assist in more accurate spelling for children who use AAC. Future research is needed to determine how language and reading abilities influence the use of computerized sounding out with children who have a range of speech intelligibility abilities and do and do not use AAC.
Kalkstein, Solomon; Scott, J Cobb; Biester, Rosette; Brownlow, Janeese A; Harpaz-Rotem, Ilan; Gur, Ruben C
2017-01-01
Mild traumatic brain injuries (mild TBIs) resulting from exposure to Improvised Explosive Devices (IEDs) are highly prevalent among veterans of the wars in Iraq and Afghanistan. This exploratory study compared the neurocognitive performance of blast-exposed veterans with (n = 19) and without (n = 15) reported symptoms of mild TBI. All subjects had diagnoses of posttraumatic stress disorder (PTSD). Neurocognitive testing was administered using a well-established computerized battery, the Penn Computerized Neuropsychological Battery (CNB), and groups were well matched on age, race, education, and time since most recent blast exposure. Although differences were not observed on CNB accuracy scores, MANOVAs revealed slower processing speed in the mTBI group when answering correctly on tests of simple and sustained attention, with large effect sizes. Results suggest a potential speed-accuracy tradeoff in blast-related mild TBI, which should be further examined in larger samples.
Lindsberg, P J; Sirén, A L; Hallenbeck, J M
1997-01-01
Controversy exists about the effect of tissue edema on cerebral microcirculation. High spatial resolution is required for observation of extravasation and microcirculation during focal vasogenic edema formation. To study the relationship between tissue edema and perfusion, we developed a technique for simultaneous visualization of extravasation and microvessel perfusion in rats. Focal intracortical microvascular injury was generated with a 1-sec Nd-YAG laser pulse. Evans blue albumin (EBA) was infused 30 min before decapitation to study extravasation and FITC-dextran was injected 30 sec prior to decapitation to examine microvessel perfusion. Computerized scanning laser-excited fluorescence microscopy followed by high resolution image analysis permitted quantitative assessment of both parameters on single fresh-frozen brain sections. Studied at 30 min (3.66 +/- 0.15 mm), 2 hr (4.14 +/- 0.08 mm, P < .05), and 8 hr (4.69 +/- 0.18 mm, P < .01) after injury, the diameter of the circular, sharply demarcated zone of EBA-extravasation increased progressively. At 30 min, microvessels at a zone surrounding the area of EBA-extravasation contained 69 +/- 14% (P < .05) more fluorescent FITC-filling than in the control hemisphere, but the density of perfused microvessels was unchanged. At 2 hr, secondary tissue changes had already occurred in a zone surrounding the initial laser lesion. While severe reduction in the density (-76 +/- 13%, P < .05) of perfused microvessels was observed within 400 to 240 microm inside the border of EBA extravasation, perfusion indexes were normal despite the presence of extravasated plasma constituents within 0-80 microm from the border. In a narrow zone (80 microm) outside the border of extravasation, individual microvessels contained 34 +/- 9% (P < .01) less FITC-fluorescence than those in a homologous area of the uninjured contralateral hemisphere. This report demonstrates the feasibility of simultaneous measurement and high-resolution mapping of indices of microvascular perfusion (density, filling) and extravasated plasma constituents in damaged and intact brain areas. In this model, the presence of extravasated plasma constituents the size of proteins did not immediately influence indices of cortical microcirculation. However, microvascular perfusion may be perturbed surrounding such an area of advancing vasogenic edema formation.
NASA Astrophysics Data System (ADS)
A novel production technology in aircraft construction was developed for manufacturing parts of shapes and dimensions that involve only small quantities for one machine. The process, called computerized integrated and automated manufacturing (CIAM), makes it possible to make ready-to-install sheet-metal parts for all types of aircraft. All of the system's job sequences, which include milling the flat sheet-metal parts in stacks, deburring, heat treatment, and forming under the high-pressure rubber-pad press, are automated. The CIAM production center, called SIAM Forming, fulfills the prerequisites for the cost-effective production of sheet-metal parts made of aluminum alloys, titanium, or steel. The SIAM procedure results in negligible material loss through computerizing both component-contour nesting of the sheet-metal parts and contour milling.
NASA Technical Reports Server (NTRS)
Nelms, W. P., Jr.; Axelson, J. A.
1974-01-01
A computerized synthesis program has been used to assess the effects of various vehicle and mission parameters on the performance of a highly maneuverable remotely piloted vehicle (RPV) for the air-to-air combat role. The configuration used in the study is a trapezoidal-wing and body concept, with forward-mounted stabilizing and control surfaces. The study mission consists of an outbound cruise, an acceleration phase, a series of subsonic and supersonic turns, and a return cruise. Performance is evaluated in terms of both the required vehicle weight to accomplish this mission and combat effectiveness as measured by turning and acceleration capability. The report describes the synthesis program, the mission, the vehicle, and the results of sensitivity and trade studies.
The Computerization of Career Services: Critical Issues To Consider.
ERIC Educational Resources Information Center
Davidson, M. Meghan
2001-01-01
Looks at the technological changes in the delivery of career services in colleges and universities and examines seven critical issues: appropriate web-based services, student diversity, ethical responsibilities, high-tech and high-touch, holistic approach, staffing and financial considerations, and outcomes. (JOW)
Benyakorn, Songpoom; Calub, Catrina A; Riley, Steven J; Schneider, Andrea; Iosif, Ana-Maria; Solomon, Marjorie; Hessl, David
2018-01-01
Background Researchers are increasingly interested in testing and developing computerized cognitive training interventions for individuals with autism spectrum disorder due to the limited accessibility of treatments for this disorder. Understanding the feasibility of testing cognitive interventions for this population is critical, especially for individuals with ASD who have low to moderate intellectual ability. Objective The aim of the study was to evaluate the feasibility of computerized cognitive training as measured by attrition rate and a parent satisfaction survey. Methods A total of 26 participants aged 8-17 years with an autism spectrum disorder diagnosis and significant intellectual impairment were enrolled (mean age 11.1 years). They were instructed to complete 25 sessions of Cogmed Working Memory Training in 5 to 6 weeks with coach assistance. Attrition rate and parent satisfaction surveys were measured after the completion of training. Results Most participants (96%, 25/26) completed the training and indicated high satisfaction (>88%). However, among the participants who completed the training, 5 participants (19%) were unable to finish in 6 weeks, the recommended training period by Cogmed. Parents noted various positive (eg, voice-overs) and negative (eg, particular graphic and sounds associated with a stimulus) features of the game that they thought affected their child’s response. Conclusions Children with autism spectrum disorder and intellectual impairments can successfully participate in computerized cognitive training interventions but may require additional weeks to complete the training beyond the time needed for children without intellectual impairments. The overall completion rate, with extended time to complete the training, was high. Developers of cognitive training programs for this population should take into account potential issues regarding the noise level of stimuli and characteristics of the visual graphics. PMID:29802090
Macatee, Richard J; Cougle, Jesse R
2015-09-01
A growing body of research has linked high distress intolerance (DI) to obsessions, but not other OCD symptom domains. However, existing research is correlational. Experimental studies are needed, but brief methods for reducing DI are lacking. To address these gaps in the literature, a brief, computerized intervention aimed at reducing DI was developed to determine if changing DI affected obsessional phenomena. Individuals reporting high DI were randomized to a treatment or waitlist control group (N = 53). Individuals in the treatment group received the DI treatment (i.e., a 2 h computerized intervention) over two weeks, and then underwent a post-assessment in which DI and obsession-relevant phenomena were measured. Individuals in the control group only received the post-assessment. Analyses revealed a greater reduction in self-reported DI on one measure and smaller decreases in behavioral DI in the intervention condition relative to the waitlist condition, as well as lower in-vivo urges to neutralize an intrusive thought; however, anxious reactivity to the intrusion and neutralization behavior were not affected. Further, bootstrapping analyses revealed that reductions in DI mediated the effect of the intervention on neutralization urges. A clinical sample and placebo control condition were not used. These results provide experimental evidence for the role of DI in obsessional phenomena, specifically in affecting urges to neutralize intrusions, findings consistent with negative reinforcement models of DI. Further, results revealed that DI can be reduced with a brief, computerized intervention, which has important implications for future experimental research and treatment development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Muselaers, Constantijn H J; Rijpkema, Mark; Bos, Desirée L; Langenhuijsen, Johan F; Oyen, Wim J G; Mulders, Peter F A; Oosterwijk, Egbert; Boerman, Otto C
2015-08-01
Tumor targeted optical imaging using antibodies labeled with near infrared fluorophores is a sensitive imaging modality that might be used during surgery to assure complete removal of malignant tissue. We evaluated the feasibility of dual modality imaging and image guided surgery with the dual labeled anti-carbonic anhydrase IX antibody preparation (111)In-DTPA-G250-IRDye800CW in mice with intraperitoneal clear cell renal cell carcinoma. BALB/c nu/nu mice with intraperitoneal SK-RC-52 lesions received 10 μg DTPA-G250-IRDye800CW labeled with 15 MBq (111)In or 10 μg of the dual labeled irrelevant control antibody NUH-82 (20 mice each). To evaluate when tumors could be detected, 4 mice per group were imaged weekly during 5 weeks with single photon emission computerized tomography/computerized tomography and the fluorescence imaging followed by ex vivo biodistribution studies. As early as 1 week after tumor cell inoculation single photon emission computerized tomography and fluorescence images showed clear delineation of intraperitoneal clear cell renal cell carcinoma with good concordance between single photon emission computerized tomography/computerized tomography and fluorescence images. The high and specific accumulation of the dual labeled antibody conjugate in tumors was confirmed in the biodistribution studies. Maximum tumor uptake was observed 1 week after inoculation (mean ± SD 58.5% ± 18.7% vs 5.6% ± 2.3% injected dose per gm for DTPA-G250-IRDye800CW vs NUH-82, respectively). High tumor uptake was also observed at other time points. This study demonstrates the feasibility of dual modality imaging with dual labeled antibody (111)In-DTPA-G250-IRDye800CW in a clear cell renal cell carcinoma model. Results indicate that preoperative and intraoperative detection of carbonic anhydrase IX expressing tumors, positive resection margins and metastasis might be feasible with this approach. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Computerizing medical records in Japan.
Yasunaga, Hideo; Imamura, Tomoaki; Yamaki, Shintaro; Endo, Hiroyoshi
2008-10-01
The present study reports the current status of computerizing medical records in Japan. In 2001, the Ministry of Health, Labour and Welfare formulated the Grand Design for the Development of Information Systems in the Healthcare and Medical Fields. The Grand Design stated a numerical target for "spreading the use of electronic medical records (EMR) in at least 60% of Japan's hospitals with 400 or more beds by 2006." The objective of this study was to examine the extent to which EMR and order entry systems (OES) have been adopted as of February 2007 and to evaluate the Japanese government's policy regarding the computerization of medical records. We conducted a postal survey targeting medical institutions throughout Japan. In February 2007, we mailed self-administered questionnaires to all 1574 hospitals with 300 or more beds, and to a random selection of 1000 hospitals with less than 300 beds in addition to 4000 clinics. Responses were received from 812 (51.6%), 504 (50.5%), and 1769 (44.8%), respectively. We asked questions concerning: (i) the extent to which EMR and OES had been introduced; (ii) the reasons why certain institutions had not introduced EMR and (iii) the subjective evaluation of the efficacy and cost-effectiveness of EMR. The percentage of institutions that had introduced EMR as of February 2007 was 10.0% for hospitals and 10.1% for clinics. Even the percentage for hospitals with 400 or more beds was just 31.2%, illustrating that the government's target had not been reached. The most common reason given for not introducing EMR was: "The cost is high" which was observed in 82.0% of hospitals. It was considered that the introduction of EMR could improve 'inter-hospital networks', and 'time efficiency for physicians' by around 45% and 25% of hospitals, respectively. Healthcare information computerization in Japan is behind schedule because the introductory costs are high. For the computerization of healthcare information to be further promoted, prices of EMR systems should be lowered to a level which individual hospitals can afford. Furthermore, the communication between EMR systems should be further standardized to secure functional and semantic interoperability in Japan.
11 CFR 9033.12 - Production of computerized information.
Code of Federal Regulations, 2012 CFR
2012-01-01
... conform to the technical specifications, including file requirements, described in the Federal Election Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal... outstanding campaign obligations. (b) Organization of computerized information and technical specifications...
11 CFR 9033.12 - Production of computerized information.
Code of Federal Regulations, 2014 CFR
2014-01-01
... conform to the technical specifications, including file requirements, described in the Federal Election Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal... outstanding campaign obligations. (b) Organization of computerized information and technical specifications...
11 CFR 9033.12 - Production of computerized information.
Code of Federal Regulations, 2013 CFR
2013-01-01
... conform to the technical specifications, including file requirements, described in the Federal Election Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal... outstanding campaign obligations. (b) Organization of computerized information and technical specifications...
Microcomputer Network for Computerized Adaptive Testing (CAT)
1984-03-01
PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized
Computerized Adaptive Testing (CAT): A User Manual
1984-03-12
NPRDC TR 84-32 COMPUTERIZED ADAPTIVE TESTING ( CAT ): A USER MANUAL Susan Hardwick Lawrence Eastman Ross Cooper Rehab Group, Incorporated San...a ~EI’IOD COVIRED COMPUTERIZED ADAPTIVE TESTING ( CAT ) Final Report Aug 1981-June 1982 A USER MANUAL 1. ~l:l’t,ORMINCI ORCI. RE~ORT NUM.I:R 62-83...II nee• .. _, entl ldentll)’ ,,. llloclr _,.,) A joint-service effort is underway to develop a computerized adaptive testing ( CAT ) system and to
Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj
2018-02-01
Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p <0.001). Kurtosis was significantly higher in each axis for calcium oxalate stones (each p <0.001). A composite algorithm using attenuation distribution pattern, average attenuation and stone size had overall 89% sensitivity, 91% specificity, 91% positive predictive value and 89% negative predictive value to predict uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Community surveillance of falls among the elderly using computerized EMS transport data.
Wofford, J L; Heuser, M D; Moran, W P; Schwartz, E; Mittelmark, M B
1994-07-01
Because falls are common among the elderly and are associated with high morbidity and mortality, community surveillance has been recommended. The purpose of this study was to characterize the impact of falls among the elderly on emergency medical transport services (EMS) and to explore the potential for community surveillance of falls through the use of computerized EMS data. Computerized EMS data and United States census data for 1990 for persons aged > or = 65 in Forsyth County, NC, were used to produce EMS transport rates for falls and to make comparisons by age, gender, race, and residence (nursing home vs community). A fall was reported as the cause for EMS summons in 15.1% (613 of 4,058) of cases. Transport rates in 1990 for falls were 7.8 per 1,000, 25.4 per 1,000, and 58.5 per 1,000 for the age groups of 65 to 74 years, 75 to 84 years, and 85 years and older. Rates were higher for females than for males (17.1 per 1,000 v 8.1 per 1,000) and higher for whites than for African-Americans (14.3 per 1,000 v 10.3 per 1,000). Rates for nursing home residents were four times that of community residents (70.6 per 1,000 v 16.0 per 1,000). Over 50% of nursing home fallers were transported between midnight and 0400 compared with 25% of community dwellers. EMS summons for older adults reporting a fall accounts for a significant portion (15%) of all transports in this county. Computerized EMS data demonstrated patterns of falls among the elderly that are consistent with known demographic factors. The potential for using computerized EMS data as a practical means of community surveillance should be further explored.
Georgiou, Andrew; Prgomet, Mirela; Paoloni, Richard; Creswick, Nerida; Hordern, Antonia; Walter, Scott; Westbrook, Johanna
2013-06-01
We undertake a systematic review of the quantitative literature related to the effect of computerized provider order entry systems in the emergency department (ED). We searched MEDLINE, EMBASE, Inspec, CINAHL, and CPOE.org for English-language studies published between January 1990 and May 2011. We identified 1,063 articles, of which 22 met our inclusion criteria. Sixteen used a pre/post design; 2 were randomized controlled trials. Twelve studies reported outcomes related to patient flow/clinical work, 7 examined decision support systems, and 6 reported effects on patient safety. There were no studies that measured decision support systems and its effect on patient flow/clinical work. Computerized provider order entry was associated with an increase in time spent on computers (up to 16.2% for nurses and 11.3% for physicians), with no significant change in time spent on patient care. Computerized provider order entry with decision support systems was related to significant decreases in prescribing errors (ranging from 17 to 201 errors per 100 orders), potential adverse drug events (0.9 per 100 orders), and prescribing of excessive dosages (31% decrease for a targeted set of renal disease medications). There are tangible benefits associated with computerized provider order entry/decision support systems in the ED environment. Nevertheless, when considered as part of a framework of technical, clinical, and organizational components of the ED, the evidence base is neither consistent nor comprehensive. Multimethod research approaches (including qualitative research) can contribute to understanding of the multiple dimensions of ED care delivery, not as separate entities but as essential components of a highly integrated system of care. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Resources for Improving Computerized Learning Environments.
ERIC Educational Resources Information Center
Yeaman, Andrew R. J.
1989-01-01
Presents an annotated review of human factors literature that discusses computerized environments. Topics discussed include the application of office automation practices to educational environments; video display terminal (VDT) workstations; health and safety hazards; planning educational facilities; ergonomics in computerized offices; and…
An overview of selected information storage and retrieval issues in computerized document processing
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Ihebuzor, Valentine U.
1984-01-01
The rapid development of computerized information storage and retrieval techniques has introduced the possibility of extending the word processing concept to document processing. A major advantage of computerized document processing is the relief of the tedious task of manual editing and composition usually encountered by traditional publishers through the immense speed and storage capacity of computers. Furthermore, computerized document processing provides an author with centralized control, the lack of which is a handicap of the traditional publishing operation. A survey of some computerized document processing techniques is presented with emphasis on related information storage and retrieval issues. String matching algorithms are considered central to document information storage and retrieval and are also discussed.
Kuhn, Andrew Warren; Solomon, Gary S
2014-01-01
Computerized neuropsychological testing batteries have provided a time-efficient and cost-efficient way to assess and manage the neurocognitive aspects of patients with sport-related concussion. These tests are straightforward and mostly self-guided, reducing the degree of clinician involvement required by traditional clinical neuropsychological paper-and-pencil tests. To determine if self-reported supervision status affected computerized neurocognitive baseline test performance in high school athletes. Retrospective cohort study. Supervised testing took place in high school computer libraries or sports medicine clinics. Unsupervised testing took place at the participant's home or another location with computer access. From 2007 to 2012, high school athletes across middle Tennessee (n = 3771) completed computerized neurocognitive baseline testing (Immediate Post-Concussion Assessment and Cognitive Testing [ImPACT]). They reported taking the test either supervised by a sports medicine professional or unsupervised. These athletes (n = 2140) were subjected to inclusion and exclusion criteria and then matched based on age, sex, and number of prior concussions. We extracted demographic and performance-based data from each de-identified baseline testing record. Paired t tests were performed between the self-reported supervised and unsupervised groups, comparing the following ImPACT baseline composite scores: verbal memory, visual memory, visual motor (processing) speed, reaction time, impulse control, and total symptom score. For differences that reached P < .05, the Cohen d was calculated to measure the effect size. Lastly, a χ(2) analysis was conducted to compare the rate of invalid baseline testing between the groups. All statistical tests were performed at the 95% confidence interval level. Self-reported supervised athletes demonstrated better visual motor (processing) speed (P = .004; 95% confidence interval [0.28, 1.52]; d = 0.12) and faster reaction time (P < .001; 95% confidence interval [-0.026, -0.014]; d = 0.21) composite scores than self-reported unsupervised athletes. Speed-based tasks were most affected by self-reported supervision status, although the effect sizes were relatively small. These data lend credence to the hypothesis that supervision status may be a factor in the evaluation of ImPACT baseline test scores.
Scientific and Technological Progress and Job Qualification.
ERIC Educational Resources Information Center
Ivanov, N. P.
Clarifying the influences determining how and to what extent highly qualified personnel are employed, this study discusses those sorts of economic and technological advances affecting employment potentials. Two main trends in scientific and technological progress--computerized industries and the high science-content of production--have so…
Computer-Controlled HVAC -- at Low Cost
ERIC Educational Resources Information Center
American School and University, 1974
1974-01-01
By tying into a computerized building-automation network, Schaumburg High School, Illinois, slashed its energy consumption by one-third. The remotely connected computer controls the mechanical system for the high school as well as other buildings in the community, with the cost being shared by all. (Author)
A composite lithology log while drilling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tannenbaum, E.; Sutcliffe, B.; Franks, A.
A new method for producing a computerized composite lithology log (CLL) while drilling by integrating MWD (measurement while drilling) and surface data is described. The CLL integrates three types of data (MWD mechanical, MWD geophysical, and surface cuttings) acquired during drilling, in three time stages: (1) Real Time. MWD drilling mechanical data including the rate of penetration and the downhole torque. This stage would provide bed boundaries and some inferred lithology. This would assist the driller with immediate drilling decisions and determine formation tops for coring, casing point, and correlation. (2) MWD Time. Recomputation of the above by adding MWDmore » geophysical data (gamma-ray, resistivity, neutron-density). This stage would upgrade the lithology inference, and give higher resolution of bed boundaries. (3) Lag Time. Detailed analysis of surface cuttings to confirm the inferred lithologies. This last input will result in a high-quality CLL with accurate lithologies and bed boundaries. The log will serve the geologist as well as the driller, petrophysicist, and reservoir engineer. It will form the basis for more comprehensive formation evaluation while drilling by adding hydrocarbon and MWD log data.« less
Computerized Sociometric Assessment for Preschool Children
ERIC Educational Resources Information Center
Endedijk, Hinke M.; Cillessen, Antonius H. N.
2015-01-01
In preschool classes, sociometric peer ratings are used to measure children's peer relationships. The current study examined a computerized version of preschool sociometric ratings. The psychometric properties were compared of computerized sociometric ratings and traditional peer ratings for preschoolers. The distributions, inter-item…
Wright-Berryman, Jennifer L; Salyers, Michelle P; O'Halloran, James P; Kemp, Aaron S; Mueser, Kim T; Diazoni, Amanda J
2013-12-01
To explore mental health consumer and provider responses to a computerized version of the Illness Management and Recovery (IMR) program. Semistructured interviews were conducted to gather data from 6 providers and 12 consumers who participated in a computerized prototype of the IMR program. An inductive-consensus-based approach was used to analyze the interview responses. Qualitative analysis revealed consumers perceived various personal benefits and ease of use afforded by the new technology platform. Consumers also highly valued provider assistance and offered several suggestions to improve the program. The largest perceived barriers to future implementation were lack of computer skills and access to computers. Similarly, IMR providers commented on its ease and convenience, and the reduction of time intensive material preparation. Providers also expressed that the use of technology creates more options for the consumer to access treatment. The technology was acceptable, easy to use, and well-liked by consumers and providers. Clinician assistance with technology was viewed as helpful to get clients started with the program, as lack of computer skills and access to computers was a concern. Access to materials between sessions appears to be desired; however, given perceived barriers of computer skills and computer access, additional supports may be needed for consumers to achieve full benefits of a computerized version of IMR. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Jousimaa, Jukkapekka; Mäkelä, Marjukka; Kunnamo, Ilkka; MacLennan, Graeme; Grimshaw, Jeremy M
2002-01-01
To compare the effects of computerized and paper-based versions of guidelines on recently qualified physicians' consultation practices. Two arm cluster randomized controlled trial. Physicians were randomized to receive computerized or textbook-based versions of the same guidelines for a 4-week study period. Physicians' compliance with guideline recommendations about laboratory, radiological, physical and other examinations, procedures, nonpharmacologic and pharmacologic treatments, physiotherapy, and referrals were measured by case note review. There were 139 recently qualified physicians working in 96 primary healthcare centers in Finland who participated in the study. Data on 4,633 patient encounters were abstracted, of which 3,484 were suitable for further analysis. Physicians' compliance with guidelines was high (over 80% for use of laboratory, radiology, physical examinations, and referrals). There were no significant differences in physicians' consultation practices in any of the measured outcomes between the computerized and textbook group. Guidelines are a useful source of information for recently qualified physicians working in primary care. However, the method of presentation of the guidelines (electronic or paper) does not have an effect on guideline use or their impact on decisions. Other factors should be considered when choosing the method of presentation of guidelines, such as information-seeking time, ease of use during the consultation, ability to update, production costs, and the physician's own preferences.
Conrad, Patricia A; Hird, Dave; Arzt, Jonathan; Hayes, Rick H; Magliano, Dave; Kasper, Janine; Morfin, Saul; Pinney, Stephen
2007-01-01
This article describes a computerized case-based CD-ROM (CD) on international animal health that was developed to give veterinary students an opportunity to "virtually" work alongside veterinarians and other veterinary students as they try to solve challenging disease problems relating to tuberculosis in South African wildlife, bovine abortion in Mexico, and neurologic disease in horses in Rapa Nui, Chile. Each of the three case modules presents, in a highly interactive format, a problem or mystery that must be solved by the learner. As well as acquiring information via video clips and text about the specific health problem, learners obtain information about the different countries, animal-management practices, diagnostic methods, related disease-control issues, economic factors, and the opinions of local experts. After assimilating this information, the learner must define the problem and formulate an action plan or make a recommendation or diagnosis. The computerized program invokes three principles of adult education: active learning, learner-centered education, and experiential learning. A medium that invokes these principles is a potentially efficient learning tool and template for developing other case-based problem-solving computerized programs. The program is accessible on the World Wide Web at
2010-01-01
Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS), New Delhi has a computerized Health Management Information System (HMIS) since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors) and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR) 1674,217 (USD 35,622). Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213). The annual savings is around INR 894,283 (USD 11,924). Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision. PMID:21078203
Technology for the product and process data base
NASA Technical Reports Server (NTRS)
Barnes, R. D.
1984-01-01
The computerized product and process data base is increasingly recognized to be the cornerstone component of an overall system aimed at the integrated automation of the industrial processes of a given company or enterprise. The technology needed to support these more effective computer integrated design and manufacturing methods, especially the concept of 3-D computer-sensible product definitions rather than engineering drawings, is not fully available and rationalized. Progress is being made, however, in bridging this technology gap with concentration on the modeling of sophisticated information and data structures, high-performance interactive user interfaces and comprehensive tools for managing the resulting computerized product definition and process data base.
Marquié, J C; Thon, B; Baracat, B
1994-06-01
The study of Bue and Gollac (1988) provided evidence that a significantly lower proportion of workers aged 45 years and over make use of computer technology compared with younger ones. The aim of the present survey was to explain this fact by a more intensive analysis of the older workers' attitude with respect to the computerization of work situations in relation to other individual and organizational factors. Six hundred and twenty office workers from 18 to 70 years old, either users or non-users of computerized devices, were asked to complete a questionnaire. The questions allowed the assessment of various aspects of the workers' current situation, such as the computer training they had received, the degree of consultation they were subjected to during the computerization process, their representation of the effects of these new technologies on working conditions and employment, the rate of use of new technologies outside the work context, and the perceived usefulness of computers for their own work. The analysis of the questionnaire revealed that as long as the step towards using computer tools, even minimally, has not been taken, then attitudes with respect to computerization are on the whole not very positive and are a source of anxiety for many workers. Age, and even more, seniority in the department, increase such negative representations. The effects of age and seniority were also found among users, as well as the effects of other factors such as qualification, education level, type and rate of computer use, and size of the firm. For the older workers, the expectation of less positive consequences for their career, or even the fear that computerization might be accompanied by threats to their own employment and the less clear knowledge of how computers operate, appeared to account for a significant part of the observed age and seniority differences in attitudes. Although the difference in the amount of computer training between age groups was smaller than expected, the study revealed that one third of the users never received any specific training, and that many of those who benefited from it were trained for only a few days. Consultation of the staff during the computerization process also appeared to be poor, to apply mostly to the best trained and qualified workers, and to be more highly developed in small companies. The results are discussed in the light of more qualitative data recorded during the survey. They suggest the need to increase information, training and involvement of all personnel from the very first stages of computerization (or other technical changes) in order to lessen fears and the feeling of disruption, which are particularly obvious among the oldest workers.
Uzun, Ismail; Gunduz, Kaan; Celenk, Peruze; Avsever, Hakan; Orhan, Kaan; Canitezer, Gozde; Ozmen, Bilal; Cicek, Ersan; Egrioglu, Erol
2015-01-01
Background: The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. Objectives: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. Materials and Methods: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm3); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm3); 3) NewTom 3G, 6˝ (0.16 mm3) and 4) NewTom 3G, 9˝ FOV (0.25 mm3). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. Results: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm3) images. Conclusion: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups. PMID:26557279
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-25
..., Software, Implants, and Components Thereof; Notice of Receipt of Complaint; Solicitation of Comments... Certain Computerized Orthopedic Surgical Devices, Software, Implants, and Components Thereof, DN 2945; the... importation of certain computerized orthopedic surgical devices, software, implants, and components thereof...
Designing a Computerized Presentation Center.
ERIC Educational Resources Information Center
Christopher, Doris A.
1995-01-01
The Office Systems and Business Education Department at California State University (Los Angeles) developed a computerized presentation center, with multimedia classrooms and a multipurpose room, where students learn computerized presentation design skills, faculty can develop materials for class, and local business can do videoconferencing and…
van Schie, H T; Bakker, E M; Jonker, A M; van Weeren, P R
2001-07-01
To evaluate effectiveness of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for quantitative evaluation of tendon structural integrity in horses. 4 superficial digital flexor tendons (2 damaged tendons, 2 normal tendons). Transverse ultrasonographic images that precisely matched histologic sections were obtained in fixed steps along the long axis of each tendon. Distribution, intensity, and delineation of structure-related echoes, quantitatively expressed as the correlation ratio and steadiness ratio , were compared with histologic findings in tissue that was normal or had necrosis, early granulation, late granulation, early fibrosis, or inferior repair. In normal tendon, the even distribution of structure-related echoes with high intensity and sharp delineation yielded high correlation ratio and steadiness ratio. In areas of necrosis, collapsed endotendon septa yielded solid but blurred structure-related echoes (high correlation ration and low steadiness ratio). In early granulation tissue, complete lack of organization caused zero values for both ratios. In late granulation tissue, reorganization and swollen endotendon septa yielded poorly delineated structure-related echoes (high correlation ratio, low steadiness ratio). In early fibrosis, rearrangement of bundles resulted in normal correlation ration and slightly low steadiness ratio. In inferior repair, the almost complete lack of structural reorganization resulted in heterogeneous poorly delineated low-intensity echoes (low correlation ratio and steadiness ratio). The combination of correlation ratio and steadiness ratio accurately reflects histopathologic findings, making computerized correlation of ultrasonographic images an efficient tool for quantitative evaluation of tendon structural integrity.
Leung, Gabriel M.; Yu, Philip L. H.; Wong, Irene O. L.; Johnston, Janice M.; Tin, Keith Y. K.
2003-01-01
Objective: Given the slow adoption of medical informatics in Hong Kong and Asia, we sought to understand the contributory barriers and potential incentives associated with information technology implementation. Design and Measurements: A representative sample of 949 doctors (response rate = 77.0%) was asked through a postal survey to rank a list of nine barriers associated with clinical computerization according to self-perceived importance. They ranked seven incentives or catalysts that may influence computerization. We generated mean rank scores and used multidimensional preference analysis to explore key explanatory dimensions of these variables. A hierarchical cluster analysis was performed to identify homogenous subgroups of respondents. We further determined the relationships between the sets of barriers and incentives/catalysts collectively using canonical correlation. Results: Time costs, lack of technical support and large capital investments were the biggest barriers to computerization, whereas improved office efficiency and better-quality care were ranked highest as potential incentives to computerize. Cost vs. noncost, physician-related vs. patient-related, and monetary vs. nonmonetary factors were the key dimensions explaining the barrier variables. Similarly, within-practice vs external and “push” vs “pull” factors accounted for the incentive variables. Four clusters were identified for barriers and three for incentives/catalysts. Canonical correlation revealed that respondents who were concerned with the costs of computerization also perceived financial incentives and government regulation to be important incentives/catalysts toward computerization. Those who found the potential interference with communication important also believed that the promise of improved care from computerization to be a significant incentive. Conclusion: This study provided evidence regarding common barriers associated with clinical computerization. Our findings also identified possible incentive strategies that may be employed to accelerate uptake of computer systems. PMID:12595409
Can computerized tomography accurately stage childhood renal tumors?
Abdelhalim, Ahmed; Helmy, Tamer E; Harraz, Ahmed M; Abou-El-Ghar, Mohamed E; Dawaba, Mohamed E; Hafez, Ashraf T
2014-07-01
Staging of childhood renal tumors is crucial for treatment planning and outcome prediction. We sought to identify whether computerized tomography could accurately predict the local stage of childhood renal tumors. We retrospectively reviewed our database for patients diagnosed with childhood renal tumors and treated surgically between 1990 and 2013. Inability to retrieve preoperative computerized tomography, intraoperative tumor spillage and nonWilms childhood renal tumors were exclusion criteria. Local computerized tomography stage was assigned by a single experienced pediatric radiologist blinded to the pathological stage, using a consensus similar to the Children's Oncology Group Wilms tumor staging system. Tumors were stratified into up-front surgery and preoperative chemotherapy groups. The radiological stage of each tumor was compared to the pathological stage. A total of 189 tumors in 179 patients met inclusion criteria. Computerized tomography staging matched pathological staging in 68% of up-front surgery (70 of 103), 31.8% of pre-chemotherapy (21 of 66) and 48.8% of post-chemotherapy scans (42 of 86). Computerized tomography over staged 21.4%, 65.2% and 46.5% of tumors in the up-front surgery, pre-chemotherapy and post-chemotherapy scans, respectively, and under staged 10.7%, 3% and 4.7%. Computerized tomography staging was more accurate in tumors managed by up-front surgery (p <0.001) and those without extracapsular extension (p <0.001). The validity of computerized tomography staging of childhood renal tumors remains doubtful. This staging is more accurate for tumors treated with up-front surgery and those without extracapsular extension. Preoperative computerized tomography can help to exclude capsular breach. Treatment strategy should be based on surgical and pathological staging to avoid the hazards of inaccurate staging. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Shocking Discoveries: Developing Internet Use Polices for the Computerized Classroom.
ERIC Educational Resources Information Center
Flechtner, Bill
1996-01-01
Gives practical approaches to dealing with the problem of student access to inappropriate materials on the Internet. Discusses how Milwaukie (Oregon) High School has dealt with Internet access for students. (TB)
Harper, Marvin B; Longhurst, Christopher A; McGuire, Troy L; Tarrago, Rod; Desai, Bimal R; Patterson, Al
2014-03-01
The study aims to develop a core set of pediatric drug-drug interaction (DDI) pairs for which electronic alerts should be presented to prescribers during the ordering process. A clinical decision support working group composed of Children's Hospital Association (CHA) members was developed. CHA Pharmacists and Chief Medical Information Officers participated. Consensus was reached on a core set of 19 DDI pairs that should be presented to pediatric prescribers during the order process. We have provided a core list of 19 high value drug pairs for electronic drug-drug interaction alerts to be recommended for inclusion as high value alerts in prescriber order entry software used with a pediatric patient population. We believe this list represents the most important pediatric drug interactions for practical implementation within computerized prescriber order entry systems.
15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...
15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...
15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...
15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...
15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...
Innovations in Computerized Assessment.
ERIC Educational Resources Information Center
Drasgow, Fritz, Ed.; Olson-Buchanan, Julie B., Ed.
Chapters in this book present the challenges and dilemmas faced by researchers as they created new computerized assessments, focusing on issues addressed in developing, scoring, and administering the assessments. Chapters are: (1) "Beyond Bells and Whistles; An Introduction to Computerized Assessment" (Julie B. Olson-Buchanan and Fritz Drasgow);…
Advanced Composition and the Computerized Library.
ERIC Educational Resources Information Center
Hult, Christine
1989-01-01
Discusses four kinds of computerized access tools: online catalogs; computerized reference; online database searching; and compact disks and read only memory (CD-ROM). Examines how these technologies are changing research. Suggests how research instruction in advanced writing courses can be refocused to include the new technologies. (RS)
Validation of a Self-Administered Computerized System to Detect Cognitive Impairment in Older Adults
Brinkman, Samuel D.; Reese, Robert J.; Norsworthy, Larry A.; Dellaria, Donna K.; Kinkade, Jacob W.; Benge, Jared; Brown, Kimberly; Ratka, Anna; Simpkins, James W.
2015-01-01
There is increasing interest in the development of economical and accurate approaches to identifying persons in the community who have mild, undetected cognitive impairments. Computerized assessment systems have been suggested as a viable approach to identifying these persons. The validity of a computerized assessment system for identification of memory and executive deficits in older individuals was evaluated in the current study. Volunteers (N = 235) completed a 3-hr battery of neuropsychological tests and a computerized cognitive assessment system. Participants were classified as impaired (n = 78) or unimpaired (n = 157) on the basis of the Mini Mental State Exam, Wechsler Memory Scale-III and the Trail Making Test (TMT), Part B. All six variables (three memory variables and three executive variables) derived from the computerized assessment differed significantly between groups in the expected direction. There was also evidence of temporal stability and concurrent validity. Application of computerized assessment systems for clinical practice and for identification of research participants is discussed in this article. PMID:25332303
Computerized neurocognitive testing in the management of sport-related concussion: an update.
Resch, Jacob E; McCrea, Michael A; Cullum, C Munro
2013-12-01
Since the late nineties, computerized neurocognitive testing has become a central component of sport-related concussion (SRC) management at all levels of sport. In 2005, a review of the available evidence on the psychometric properties of four computerized neuropsychological test batteries concluded that the tests did not possess the necessary criteria to warrant clinical application. Since the publication of that review, several more computerized neurocognitive tests have entered the market place. The purpose of this review is to summarize the body of published studies on psychometric properties and clinical utility of computerized neurocognitive tests available for use in the assessment of SRC. A review of the literature from 2005 to 2013 was conducted to gather evidence of test-retest reliability and clinical validity of these instruments. Reviewed articles included both prospective and retrospective studies of primarily sport-based adult and pediatric samples. Summaries are provided regarding the available evidence of reliability and validity for the most commonly used computerized neurocognitive tests in sports settings.
Computerized Numerical Control Curriculum Guide.
ERIC Educational Resources Information Center
Reneau, Fred; And Others
This guide is intended for use in a course in programming and operating a computerized numerical control system. Addressed in the course are various aspects of programming and planning, setting up, and operating machines with computerized numerical control, including selecting manual or computer-assigned programs and matching them with…
A Markov Model Analysis of Problem-Solving Progress.
ERIC Educational Resources Information Center
Vendlinski, Terry
This study used a computerized simulation and problem-solving tool along with artificial neural networks (ANN) as pattern recognizers to identify the common types of strategies high school and college undergraduate chemistry students would use to solve qualitative chemistry problems. Participants were 134 high school chemistry students who used…
Paquerault, Sophie; Hardy, Paul T; Wersto, Nancy; Chen, John; Smith, Robert C
2010-09-01
The aim of this study was to explore different computerized models (the "machine") as a means to achieve optimal use of computer-aided detection (CAD) systems and to investigate whether these models can play a primary role in clinical decision making and possibly replace a clinician's subjective decision for combining his or her own assessment with that provided by a CAD system. Data previously collected from a fully crossed, multiple-reader, multiple-case observer study with and without CAD by seven observers asked to identify simulated small masses on two separate sets of 100 mammographic images (low-contrast and high-contrast sets; ie, low-contrast and high-contrast simulated masses added to random locations on normal mammograms) were used. This allowed testing two relative sensitivities between the observers and CAD. Seven models that combined detection assessments from CAD standalone, unaided read, and CAD-aided read (second read and concurrent read) were developed using the leave-one-out technique for training and testing. These models were personalized for each observer. Detection performance accuracies were analyzed using the area under a portion of the free-response receiver-operating characteristic curve (AUFC), sensitivity, and number of false-positives per image. For the low-contrast set, the use of computerized models resulted in significantly higher AUFCs compared to the unaided read mode for all readers, whereas the increased AUFCs between CAD-aided (second and concurrent reads; ie, decisions made by the readers) and unaided read modes were statistically significant for a majority, but not all, of the readers (four and five of the seven readers, respectively). For the high-contrast set, there were no significant trends in the AUFCs whether or not a model was used to combine the original reading modes. Similar results were observed when using sensitivity as the figure of merit. However, the average number of false-positives per image resulting from the computerized models remained the same as that obtained from the unaided read modes. Individual computerized models (the machine) that combine image assessments from CAD standalone, unaided read, and CAD-aided read can increase detection performance compared to the reading done by the observer. However, relative sensitivity (ie, the difference in sensitivity between CAD standalone and unaided read) was a critical factor that determined incremental improvement in decision making, whether made by the observer or using computerized models. Published by Elsevier Inc.
An Application of the Rasch Model to Computerized Adaptive Testing.
ERIC Educational Resources Information Center
Wisniewski, Dennis R.
Three questions concerning the Binary Search Method (BSM) of computerized adaptive testing were studied: (1) whether it provided a reliable and valid estimation of examinee ability; (2) its effect on examinee attitudes toward computerized adaptive testing and conventional paper-and-pencil testing; and (3) the relationship between item response…
The Reality, Direction, and Future of Computerized Publications
ERIC Educational Resources Information Center
Levenstein, Nicholas
2012-01-01
Sharing information in digital form by using a computer is a growing phenomenon. Many universities are making their applications available on computer. More than one hundred and thirty-six universities have developed computerized applications on their own or through a commercial vendor. Universities developed computerized applications in order to…
Evaluating a Computerized Aid for Conducting a Cognitive Task Analysis
2000-01-01
in conducting a cognitive task analysis . The conduct of a cognitive task analysis is costly and labor intensive. As a result, a few computerized aids...evaluation of a computerized aid, specifically CAT-HCI (Cognitive Analysis Tool - Human Computer Interface), for the conduct of a detailed cognitive task analysis . A
Computerized Classification Testing with the Rasch Model
ERIC Educational Resources Information Center
Eggen, Theo J. H. M.
2011-01-01
If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…
Computerized Adaptive Assessment of Cognitive Abilities among Disabled Adults.
ERIC Educational Resources Information Center
Engdahl, Brian
This study examined computerized adaptive testing and cognitive ability testing of adults with cognitive disabilities. Adult subjects (N=250) were given computerized tests on language usage and space relations in one of three administration conditions: paper and pencil, fixed length computer adaptive, and variable length computer adaptive.…
Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing
ERIC Educational Resources Information Center
Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin
2010-01-01
The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…
Year 2000 Computerized Farm Project. Final Report.
ERIC Educational Resources Information Center
McGrann, James M.; Lippke, Lawrence A.
An ongoing project was funded to develop and demonstrate a computerized approach to operation and management of a commercial-sized farm. Other project objectives were to facilitate the demonstration of the computerized farm to the public and to develop individual software packages and make them available to the public. Project accomplishments…
10 CFR 719.44 - What categories of costs require advance approval?
Code of Federal Regulations, 2014 CFR
2014-01-01
... application software, or non-routine computerized databases, if they are specifically created for a particular matter. For costs associated with the creation and use of computerized databases, contractors and retained legal counsel must ensure that the creation and use of computerized databases is necessary and...
Computerized Diagnostic Testing: Problems and Possibilities.
ERIC Educational Resources Information Center
McArthur, David L.
The use of computers to build diagnostic inferences is explored in two contexts. In computerized monitoring of liquid oxygen systems for the space shuttle, diagnoses are exact because they can be derived within a world which is closed. In computerized classroom testing of reading comprehension, programs deliver a constrained form of adaptive…
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENFORCEMENT SYSTEMS § 307.13 Security and confidentiality for computerized support enforcement systems in... systems in operation after October 1, 1997. (a) Information integrity and security. Have safeguards... 45 Public Welfare 2 2010-10-01 2010-10-01 false Security and confidentiality for computerized...
A First Life with Computerized Business Simulations
ERIC Educational Resources Information Center
Thavikulwat, Precha
2011-01-01
The author discusses the theoretical lens, origins, and environment of his work on computerized business simulations. Key ideas that inform his work include the two dimensions (control and interaction) of computerized simulation, the two ways of representing a natural process (phenotypical and genotypical) in a simulation, which he defines as a…
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS..., organization, services and constraints related to the computerized support enforcement system; (4) The APD must... design, development, installation or enhancement; (5) The APD must contain a description of each...
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS..., organization, services and constraints related to the computerized support enforcement system; (4) The APD must... design, development, installation or enhancement; (5) The APD must contain a description of each...
45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS..., organization, services and constraints related to the computerized support enforcement system; (4) The APD must... design, development, installation or enhancement; (5) The APD must contain a description of each...
Protecting Privacy in Computerized Medical Information.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. Office of Technology Assessment.
This report analyzes the implications of computerized medical information and the challenges it brings to individual privacy. The report examines the nature of the privacy interest in health care information and the current state of the law protecting that information; the nature of proposals to computerize health care information and the…
45 CFR 310.25 - What conditions apply to acquisitions of Computerized Tribal IV-D Systems?
Code of Federal Regulations, 2010 CFR
2010-10-01
... FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION... Acquisition Threshold; (c) Software and ownership rights. (1) All procurement and contract instruments must... Computerized Tribal IV-D System software or enhancements thereof and all associated documentation designed...
Computerization of the Newspaper in the 1980s.
ERIC Educational Resources Information Center
Garrison, Bruce
A review of the literature on the computerization of newspaper newsrooms shows that since 1960, computers have assumed an increasingly important role in information collection, news writing and editing, pagination, and news transmission. When newspaper libraries are computerized, reporters are able to find information more quickly and to use…
[Computerized medical record: deontology and legislation].
Allaert, F A; Dusserre, L
1996-02-01
Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.
Tzeng, Huey-Ming; Hu, Hsou Mei; Yin, Chang-Yi
2011-12-01
Medicare no longer reimburses acute care hospitals for the costs of additional care required due to hospital-acquired injuries. Consequently, this study explored the effective computerized systems to inform practice for better interventions to reduce fall risk. It provided a correlation between type of computerized system and hospital-acquired injurious fall rates at acute care hospitals in California, Florida, and New York. It used multiple publicly available data sets, with the hospital as the unit of analysis. Descriptive and Pearson correlation analyses were used. The analysis included 462 hospitals. Significant correlations could be categorized into two groups: (1) meaningful computerized systems that were associated with lower injurious fall rates: the decision support systems for drug allergy alerts, drug-drug interaction alerts, and drug-laboratory interaction alerts; and (2) computerized systems that were associated with higher injurious fall rates: the decision support system for drug-drug interaction alerts and the computerized provider order entry system for radiology tests. Future research may include additional states, multiple years of data, and patient-level data to validate this study's findings. This effort may further inform policy makers and the public about effective clinical computerized systems provided to clinicians to improve their practice decisions and care outcomes.
Educational Attainment of Workers, March 1981.
ERIC Educational Resources Information Center
Young, Anne McDougall
1982-01-01
According to March 1981 statistics from the Current Population Survey: (1) college graduates had the highest labor force participation rates, and high school dropouts, the lowest, and (2) computerization of the workplace supported this proportion. (CT)
Moja, Lorenzo; Polo Friz, Hernan; Capobussi, Matteo; Kwag, Koren; Banzi, Rita; Ruggiero, Francesca; González-Lorenzo, Marien; Liberati, Elisa Giulia; Mangia, Massimo; Nyberg, Peter; Kunnamo, Ilkka; Cimminiello, Claudio; Vighi, Giuseppe; Grimshaw, Jeremy; Bonovas, Stefanos
2016-07-07
Computerized decision support systems (CDSSs) are information technology-based software that provide health professionals with actionable, patient-specific recommendations or guidelines for disease diagnosis, treatment, and management at the point-of-care. These messages are intelligently filtered to enhance the health and clinical care of patients. CDSSs may be integrated with patient electronic health records (EHRs) and evidence-based knowledge. We designed a pragmatic randomized controlled trial to evaluate the effectiveness of patient-specific, evidence-based reminders generated at the point-of-care by a multi-specialty decision support system on clinical practice and the quality of care. We will include all the patients admitted to the internal medicine department of one large general hospital. The primary outcome is the rate at which medical problems, which are detected by the decision support software and reported through the reminders, are resolved (i.e., resolution rates). Secondary outcomes are resolution rates for reminders specific to venous thromboembolism (VTE) prevention, in-hospital all causes and VTE-related mortality, and the length of hospital stay during the study period. The adoption of CDSSs is likely to increase across healthcare systems due to growing concerns about the quality of medical care and discrepancy between real and ideal practice, continuous demands for a meaningful use of health information technology, and the increasing use of and familiarity with advanced technology among new generations of physicians. The results of our study will contribute to the current understanding of the effectiveness of CDSSs in primary care and hospital settings, thereby informing future research and healthcare policy questions related to the feasibility and value of CDSS use in healthcare systems. This trial is seconded by a specialty trial randomizing patients in an oncology setting (ONCO-CODES). ClinicalTrials.gov, https://clinicaltrials.gov/ct2/show/NCT02577198?term=NCT02577198&rank=1.
NASA Astrophysics Data System (ADS)
Nishikawa, Robert M.; Giger, Maryellen L.; Doi, Kunio; Vyborny, Carl J.; Schmidt, Robert A.; Metz, Charles E.; Wu, Chris Y.; Yin, Fang-Fang; Jiang, Yulei; Huo, Zhimin; Lu, Ping; Zhang, Wei; Ema, Takahiro; Bick, Ulrich; Papaioannou, John; Nagel, Rufus H.
1993-07-01
We are developing an 'intelligent' workstation to assist radiologists in diagnosing breast cancer from mammograms. The hardware for the workstation will consist of a film digitizer, a high speed computer, a large volume storage device, a film printer, and 4 high resolution CRT monitors. The software for the workstation is a comprehensive package of automated detection and classification schemes. Two rule-based detection schemes have been developed, one for breast masses and the other for clustered microcalcifications. The sensitivity of both schemes is 85% with a false-positive rate of approximately 3.0 and 1.5 false detections per image, for the mass and cluster detection schemes, respectively. Computerized classification is performed by an artificial neural network (ANN). The ANN has a sensitivity of 100% with a specificity of 60%. Currently, the ANN, which is a three-layer, feed-forward network, requires as input ratings of 14 different radiographic features of the mammogram that were determined subjectively by a radiologist. We are in the process of developing automated techniques to objectively determine these 14 features. The workstation will be placed in the clinical reading area of the radiology department in the near future, where controlled clinical tests will be performed to measure its efficacy.
Outbreak of silicosis in Spanish quartz conglomerate workers
Pérez-Alonso, Aránzazu; Córdoba-Doña, Juan Antonio; Millares-Lorenzo, José Luis; Figueroa-Murillo, Estrella; García-Vadillo, Cristina; Romero-Morillo, José
2014-01-01
Objectives: To describe the epidemiological and clinical characteristics of an outbreak of occupational silicosis and the associated working conditions. Methods: Cases were defined as men working in the stone cutting, shaping, and finishing industry in the province of Cádiz, diagnosed with silicosis between July 2009 and May 2012, and were identified and diagnosed by the department of pulmonology of the University Hospital of Puerto Real (Cádiz). A census of workplaces using quartz conglomerates was carried out to determine total numbers of potentially exposed workers. A patient telephone survey on occupational exposures and a review of medical records for all participants were conducted. Results: Silicosis was diagnosed in 46 men with a median age of 33 years and a median of 11 years working in the manufacturing of countertops. Of these cases, 91.3% were diagnosed with simple chronic silicosis, with an abnormal high-resolution computerized tomography (HRCT) scan. One patient died during the study period. Employer non-compliance in prevention and control measures was frequently reported, as were environmental and individual protection failures. Conclusions: The use of new construction materials such as quartz conglomerates has increased silicosis incidence due to intensive occupational exposures, in the context of high demand fuelled by the housing boom. This widespread exposure poses a risk if appropriate preventive measures are not undertaken. PMID:24804337
NASA Astrophysics Data System (ADS)
Yaroslavsky, Ilya; Vinnichenko, Victoria; McNeill, Tyler; Novoseltseva, Anna; Perchuk, Igor; Vybornov, Alexander; Altshuler, Gregory; Gapontsev, Valentin
2018-02-01
Recently, a Thulium (Tm) fiber laser operating at a wavelength of 1940 nm and peak power up to 500 W has been introduced as a promising energy source for laser lithotripsy. Direct comparative studies have demonstrated considerable advantages of Tm fiber laser over the current industry-standard 2100 nm Holmium:YAG (Ho:YAG) device in terms of ablation rate and retropulsion effects. In this work, we investigated avenues of further improving stone ablation efficiency and reducing retropulsion. Specifically, the roles of temporal pulse structure and fiber tip preparation were studied in detail. Experiments were conducted on Bego stone phantoms in an aqueous environment using a computerized 2D stage for controlled scanning of the fiber over the stone surface. High-resolution 3D-enabled optical microscopy was employed to assess both fiber tip damage and stone ablation rate. Retropulsion effects were quantified using a high-speed video camera. Fiber burn back was evaluated as well. Fiber performance could be preserved during prolonged (up to 15 min) procedures when the fiber tip was adequately prepared. Furthermore, the results were compared with available literature for similar experiments performed with the Ho:YAG laser. The data obtained provide an important foundation for optimizing clinical performance of Tm fiber systems for lithotripsy.
Assessment of Minimal HE (with emphasis on computerized psychometric tests)
Kappus, Matthew R; Bajaj, Jasmohan S
2012-01-01
Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464
A computerized clinical decision support system as a means of implementing depression guidelines.
Trivedi, Madhukar H; Kern, Janet K; Grannemann, Bruce D; Altshuler, Kenneth Z; Sunderajan, Prabha
2004-08-01
The authors describe the history and current use of computerized systems for implementing treatment guidelines in general medicine as well as the development, testing, and early use of a computerized decision support system for depression treatment among "real-world" clinical settings in Texas. In 1999 health care experts from Europe and the United States met to confront the well-documented challenges of implementing treatment guidelines and to identify strategies for improvement. They suggested the integration of guidelines into computer systems that is incorporated into clinical workflow. Several studies have demonstrated improvements in physicians' adherence to guidelines when such guidelines are provided in a computerized format. Although computerized decision support systems are being used in many areas of medicine and have demonstrated improved patient outcomes, their use in psychiatric illness is limited. The authors designed and developed a computerized decision support system for the treatment of major depressive disorder by using evidence-based guidelines, transferring the knowledge gained from the Texas Medication Algorithm Project (TMAP). This computerized decision support system (CompTMAP) provides support in diagnosis, treatment, follow-up, and preventive care and can be incorporated into the clinical setting. CompTMAP has gone through extensive testing to ensure accuracy and reliability. Physician surveys have indicated a positive response to CompTMAP, although the sample was insufficient for statistical testing. CompTMAP is part of a new era of comprehensive computerized decision support systems that take advantage of advances in automation and provide more complete clinical support to physicians in clinical practice.
Assessment of minimal hepatic encephalopathy (with emphasis on computerized psychometric tests).
Kappus, Matthew R; Bajaj, Jasmohan S
2012-02-01
Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life, and driving accidents. The detection of MHE requires specialized testing because it cannot, by definition, be diagnosed on standard clinical examination. Psychometric and neurophysiologic techniques are often used to test for MHE. Paper-pencil psychometric batteries and computerized tests have proved useful in diagnosing MHE and predicting its outcomes. Neurophysiologic tests also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike. Testing strategies depend on the normative data available, patient comfort, and local expertise. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Valdman, V. V.; Gridnev, S. O.
2017-10-01
The article examines into the vital issues of measuring and calculating the raw stock volumes in covered storehouses at mining and processing plants. The authors bring out two state-of-the-art high-technology solutions: 1 - to use the ground-based laser scanning system (the method is reasonably accurate and dependable, but costly and time consuming; it also requires the stoppage of works in the storehouse); 2 - to use the fundamentally new computerized stocktaking system in mine surveying for the ore mineral volume calculation, based on the profile digital images. These images are obtained via vertical projection of the laser plane onto the surface of the stored raw materials.
Computerized Adaptive Test (CAT) Applications and Item Response Theory Models for Polytomous Items
ERIC Educational Resources Information Center
Aybek, Eren Can; Demirtasli, R. Nukhet
2017-01-01
This article aims to provide a theoretical framework for computerized adaptive tests (CAT) and item response theory models for polytomous items. Besides that, it aims to introduce the simulation and live CAT software to the related researchers. Computerized adaptive test algorithm, assumptions of item response theory models, nominal response…
ERIC Educational Resources Information Center
Gullo, Shirna R.
2014-01-01
Computerized testing may be one solution to enhance performance on the curricular Health Education Systems Inc. (HESI) exam and the National Council Licensure Exam for Registered Nurses (NCLEX-RN). Due to the integration of improved technological processes and procedures in healthcare for computerized documentation and electronicmedical records,…
ERIC Educational Resources Information Center
Wu, Huey-Min; Kuo, Bor-Chen; Wang, Su-Chen
2017-01-01
In this study, a computerized dynamic assessment test with both immediately individualized feedback and adaptively property was applied to Mathematics learning in primary school. For evaluating the effectiveness of the computerized dynamic adaptive test, the performances of three types of remedial instructions were compared by a pre-test/post-test…
Computerized Management of Physical Plant Services.
ERIC Educational Resources Information Center
Hawkey, Earl W.; Kleinpeter, Joseph
Outlining the major areas to be considered when deciding whether or not to computerize physical plant services in higher education institutions, the author points out the shortcomings of manual record keeping systems. He gives five factors to consider when deciding to computerize: (1) time and money, (2) extent of operation, (3) current and future…
The Evaluation of SISMAKOM (Computerized SDI Project).
ERIC Educational Resources Information Center
University of Science, Penang (Malaysia).
A survey of 88 users of SISMAKOM, a computerized selective dissemination of information (SDI) and document delivery service provided by the Universiti Sains Malaysia and four other Malaysian universities, was conducted in August 1982 in order to collect data about SISMAKOM and to assess the value of a computerized SDI service in a developing…
ERIC Educational Resources Information Center
Klemes, Joel; Epstein, Alit; Zuker, Michal; Grinberg, Nira; Ilovitch, Tamar
2006-01-01
The current study examines how a computerized learning environment assists students with learning disabilities (LD) enrolled in a distance learning course at the Open University of Israel. The technology provides computer display of the text, synchronized with auditory output and accompanied by additional computerized study skill tools which…
ERIC Educational Resources Information Center
Sabbah, Sabah Salman
2015-01-01
This study explored the potential effect of college students' self-generated computerized mind maps on their reading comprehension. It also investigated the subjects' attitudes toward generating computerized mind maps for reading comprehension. The study was conducted in response to the inability of the foundation-level students, who were learning…
The Impact of Computerization on Archival Finding Aids: A RAMP Study.
ERIC Educational Resources Information Center
Kitching, Christopher
This report is based on a questionnaire sent to 32 selected National Archives and on interviews with archivists from eight countries. Geared to the needs of developing countries, the report covers: (1) the impact of computerization on finding aids; (2) advantages and problems of computerization, including enhanced archival control, integration of…
Uhm, Yo-Han; Yang, Dae-Jung
2018-02-01
[Purpose] The purpose of this study was to examine the effect of computerized postural control training using whole body vibration on lower limb muscle activity and cerebral cortical activation in acute stroke patients. [Subjects and Methods] Thirty stroke patients participated and were divided into groups of 10, a group of the computerized postural control training using whole body vibration (Group I), the computerized postural control training combined with aero step (Group II) and computerized postural control training (Group III). MP100 was used to measure lower limb muscle activity, and QEEG-8 was used to measure cerebral cortical activation. [Results] Comparison of muscle activity and cerebral cortical activation before and after intervention between groups showed that Group I had significant differences in lower limb muscle activity and cerebral cortical activation compared to Groups II and III. [Conclusion] This study showed that whole body vibration combined computerized postural control training is effective for improving muscle activity and cerebral cortex activity in stroke patients.
Investigation of computer-aided colonic crypt pattern analysis
NASA Astrophysics Data System (ADS)
Qi, Xin; Pan, Yinsheng; Sivak, Michael V., Jr.; Olowe, Kayode; Rollins, Andrew M.
2007-02-01
Colorectal cancer is the second leading cause of cancer-related death in the United States. Approximately 50% of these deaths could be prevented by earlier detection through screening. Magnification chromoendoscopy is a technique which utilizes tissue stains applied to the gastrointestinal mucosa and high-magnification endoscopy to better visualize and characterize lesions. Prior studies have shown that shapes of colonic crypts change with disease and show characteristic patterns. Current methods for assessing colonic crypt patterns are somewhat subjective and not standardized. Computerized algorithms could be used to standardize colonic crypt pattern assessment. We have imaged resected colonic mucosa in vitro (N = 70) using methylene blue dye and a surgical microscope to approximately simulate in vivo imaging with magnification chromoendoscopy. We have developed a method of computerized processing to analyze the crypt patterns in the images. The quantitative image analysis consists of three steps. First, the crypts within the region of interest of colonic tissue are semi-automatically segmented using watershed morphological processing. Second, crypt size and shape parameters are extracted from the segmented crypts. Third, each sample is assigned to a category according to the Kudo criteria. The computerized classification is validated by comparison with human classification using the Kudo classification criteria. The computerized colonic crypt pattern analysis algorithm will enable a study of in vivo magnification chromoendoscopy of colonic crypt pattern correlated with risk of colorectal cancer. This study will assess the feasibility of screening and surveillance of the colon using magnification chromoendoscopy.
Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo
2015-11-01
There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Computerized screening for cognitive impairment in patients with COPD.
Campman, Carlijn; van Ranst, Dirk; Meijer, Jan Willem; Sitskoorn, Margriet
2017-01-01
COPD is associated with cognitive impairment. These impairments should be diagnosed, but due to time- and budget-reasons, they are often not investigated. The aim of this study is to examine the viability of a brief computerized cognitive test battery, Central Nervous System Vital Signs (CNSVS), in COPD patients. Patients with COPD referred to tertiary pulmonary rehabilitation were included. Cognitive functioning of patients was assessed with CNSVS before pulmonary rehabilitation and compared with age-corrected CNSVS norms. CNSVS is a 30 minute computerized test battery that includes tests of verbal and visual memory, psychomotor speed, processing speed, cognitive flexibility, complex attention, executive functioning, and reaction time. CNSVS was fully completed by 205 (93.2%, 105 females, 100 males) of the total group of patients (n=220, 116 females, 104 males). Z -tests showed that COPD patients performed significantly worse than the norms on all CNSVS cognitive domains. Slightly more than half of the patients (51.8%) had impaired functioning on 1 or more cognitive domains. Patients without computer experience performed significantly worse on CNSVS than patients using the computer frequently. The completion rate of CNSVS was high and cognitive dysfunctions measured with this screening were similar to the results found in prior research, including paper and pen cognitive tests. These results support the viability of this brief computerized cognitive screening in COPD patients, that may lead to better care for these patients. Cognitive performance of patients with little computer experience should be interpreted carefully. Future research on this issue is needed.
Research on nursing handoffs for medical and surgical settings: an integrative review.
Staggers, Nancy; Blaz, Jacquelyn W
2013-02-01
To synthesize outcomes from research on handoffs to guide future computerization of the process on medical and surgical units. Handoffs can create important information gaps, omissions and errors in patient care. Authors call for the computerization of handoffs; however, a synthesis of the literature is not yet available that might guide computerization. PubMed, CINAHL, Cochrane, PsycINFO, Scopus and a handoff database from Cohen and Hilligoss. Integrative literature review. This integrative review included studies from 1980-March 2011 in peer-reviewed journals. Exclusions were studies outside medical and surgical units, handoff education and nurses' perceptions. The search strategy yielded a total of 247 references; 81 were retrieved, read and rated for relevance and research quality. A set of 30 articles met relevance criteria. Studies about handoff functions and rituals are saturated topics. Verbal handoffs serve important functions beyond information transfer and should be retained. Greater consideration is needed on analysing handoffs from a patient-centred perspective. Handoff methods should be highly tailored to nurses and their contextual needs. The current preference for bedside handoffs is not supported by available evidence. The specific handoff structure for all units may be less important than having a structure for contextually based handoffs. Research on pertinent information content for contextually based handoffs is an urgent need. Without it, handoff computerization is not likely to be successful. Researchers need to use more sophisticated experimental research designs, control for individual and unit differences and improve sampling frames. © 2012 Blackwell Publishing Ltd.
Normal computerized Q wave measurements in healthy young athletes.
Saini, Divakar; Grober, Aaron F; Hadley, David; Froelicher, Victor
Recent Expert consensus statements have sought to decrease false positive rates of electrocardiographic abnormalities requiring further evaluation when screening young athletes. These statements are largely based on traditional ECG patterns and have not considered computerized measurements. To define the normal limits for Q wave measurements from the digitally recorded ECGs of healthy young athletes. All athletes were categorized by sex and level of participation (high school, college, and professional), and underwent screening ECGs with routine pre-participation physicals, which were electronically captured and analyzed. Q wave amplitude, area and duration were recorded for athletes with Q wave amplitudes greater than 0.5mm at standard paper amplitude display (1mV/10mm). ANOVA analyses were performed to determine differences these parameters among all groups. A positive ECG was defined by our Stanford Computerized Criteria as exceeding the 99th percentile for Q wave area in 2 or more leads. Proportions testing was used to compare the Seattle Conference Q wave criteria with our data-driven criteria. 2073 athletes in total were screened. Significant differences in Q wave amplitude, duration and area were identified both by sex and level of participation. When applying our Stanford Computerized Criteria and the Seattle criteria to our cohort, two largely different groups of athletes are identified as having abnormal Q waves. Computer analysis of athletes' ECGs should be included in future studies that have greater numbers, more diversity and adequate end points. Copyright © 2017 Elsevier Inc. All rights reserved.
Lau, Brian C; Collins, Michael W; Lovell, Mark R
2011-06-01
Concussions affect an estimated 136 000 high school athletes yearly. Computerized neurocognitive testing has been shown to be appropriately sensitive and specific in diagnosing concussions, but no studies have assessed its utility to predict length of recovery. Determining prognosis during subacute recovery after sports concussion will help clinicians more confidently address return-to-play and academic decisions. To quantify the prognostic ability of computerized neurocognitive testing in combination with symptoms during the subacute recovery phase from sports-related concussion. Cohort study (prognosis); Level of evidence, 2. In sum, 108 male high school football athletes completed a computer-based neurocognitive test battery within 2.23 days of injury and were followed until returned to play as set by international guidelines. Athletes were grouped into protracted recovery (>14 days; n = 50) or short-recovery (≤14 days; n = 58). Separate discriminant function analyses were performed using total symptom score on Post-Concussion Symptom Scale, symptom clusters (migraine, cognitive, sleep, neuropsychiatric), and Immediate Postconcussion Assessment and Cognitive Testing neurocognitive scores (verbal memory, visual memory, reaction time, processing speed). Multiple discriminant function analyses revealed that the combination of 4 symptom clusters and 4 neurocognitive composite scores had the highest sensitivity (65.22%), specificity (80.36%), positive predictive value (73.17%), and negative predictive value (73.80%) in predicting protracted recovery. Discriminant function analyses of total symptoms on the Post-Concussion Symptom Scale alone had a sensitivity of 40.81%; specificity, 79.31%; positive predictive value, 62.50%; and negative predictive value, 61.33%. The 4 symptom clusters alone discriminant function analyses had a sensitivity of 46.94%; specificity, 77.20%; positive predictive value, 63.90%; and negative predictive value, 62.86%. Discriminant function analyses of the 4 computerized neurocognitive scores alone had a sensitivity of 53.20%; specificity, 75.44%; positive predictive value, 64.10%; and negative predictive value, 66.15%. The use of computerized neurocognitive testing in conjunction with symptom clusters results improves sensitivity, specificity, positive predictive value, and negative predictive value of predicting protracted recovery compared with each used alone. There is also a net increase in sensitivity of 24.41% when using neurocognitive testing and symptom clusters together compared with using total symptoms on Post-Concussion Symptom Scale alone.
NASA Technical Reports Server (NTRS)
1976-01-01
The primary objective of this study was to develop an integrated approach for the development, implementation, and utilization of all software that is required to efficiently and cost-effectively support advanced technology laboratory flight and ground operations. It was recognized that certain aspects of the operations would be mandatory computerized services; computerization of other aspects would be optional. Thus, the analyses encompassed not only alternate computer utilization and implementations but trade studies of the programmatic effects of non-computerized versus computerized approaches to the operations. A general overview of the study is presented.
Macori, F; Iacari, V; Falchetto Osti, M; Potente, G; Anaveri, G
1998-01-01
High Resolution Computed Tomography (HRCT) has been used by many authors to study the early complications of lung transplantation. Bronchoscopy, transbronchial biopsy and the clinical parameters are the tools of choice to diagnose such complications; HRCT showed excellent sensitivity (100%) and good specificity (93%) especially in detecting bronchial stenoses. We report the preliminary results of HRCT in detecting early/late complications in lung transplant recipients. Sixteen lung transplant recipients (5 single and 11 double transplants) were examined with HRCT at the Servizio Speciale Diagnostica V of "La Sapienza" University (Rome, Italy). The CT findings were compared with the results of bronchoscopy and respiratory function tests. The patients (8 men and 8 women; age range: 18-57 years, mean: 37.5) had cystic fibrosis (9), emphysema (3), alpha-1-antitrypsin deficiency (1), idiopathic pulmonary fibrosis (2), and bronchiectasis (1). During the follow-up, one patient died of pulmonary edema. CT findings were normal in 3 patients and mild pleural effusion was seen in 2. The other HRCT findings were: bronchial stenosis in 5 cases (which was bilateral in 1) and bronchial dehiscence in 1 patient; four cases of infection (1 CMV, 1 aspecific bacterial pneumonia, 1 Chlamydia psittacea and 1 Aspergillosis) and one of brochiolitis obliterans. A patient was treated for acute and one for chronic rejection. A CMV infection involved only the native lung in a patient. CT is easy to perform and a repeatable and well-tolerated tool with high sensitivity (100%) and good specificity (93%) in the early diagnosis of complications, particularly bronchial stenoses, which complications are often missed at bronchoscopy or clinically silent. CT should be always performed before bronchoscopy because it can provide valuable information for bronchoscopy targeting. In agreement with other authors we consider HRCT a very useful tool in the early diagnosis of the complications following lung transplantation.
Truyers, Carla; Lesaffre, Emmanuel; Bartholomeeusen, Stefaan; Aertgeerts, Bert; Snacken, René; Brochier, Bernard; Yane, Fernande; Buntinx, Frank
2010-03-22
Computerized morbidity registration networks might serve as early warning systems in a time where natural epidemics such as the H1N1 flu can easily spread from one region to another. In this contribution we examine whether general practice based broad-spectrum computerized morbidity registration networks have the potential to act as a valid surveillance instrument of frequently occurring diseases. We compare general practice based computerized data assessing the frequency of influenza-like illness (ILI) and acute respiratory infections (ARI) with data from a well established case-specific sentinel network, the European Influenza Surveillance Scheme (EISS). The overall frequency and trends of weekly ILI and ARI data are compared using both networks. Detection of influenza-like illness and acute respiratory illness occurs equally fast in EISS and the computerized network. The overall frequency data for ARI are the same for both networks, the overall trends are similar, but the increases and decreases in frequency do not occur in exactly the same weeks. For ILI, the overall rate was slightly higher for the computerized network population, especially before the increase of ILI, the overall trend was almost identical and the increases and decreases occur in the same weeks for both networks. Computerized morbidity registration networks are a valid tool for monitoring frequent occurring respiratory diseases and the detection of sudden outbreaks.
Automated Simultaneous Assembly of Multistage Testlets for a High-Stakes Licensing Examination
ERIC Educational Resources Information Center
Breithaupt, Krista; Hare, Donovan R.
2007-01-01
Many challenges exist for high-stakes testing programs offering continuous computerized administration. The automated assembly of test questions to exactly meet content and other requirements, provide uniformity, and control item exposure can be modeled and solved by mixed-integer programming (MIP) methods. A case study of the computerized…
Test-Taking Skills in College Students with and without ADHD
ERIC Educational Resources Information Center
Lewandowski, Lawrence; Gathje, Rebecca A.; Lovett, Benjamin J.; Gordon, Michael
2013-01-01
College students with attention deficit hyperactivity disorder (ADHD) often request and receive extended time to complete high-stakes exams and classroom tests. This study examined the performances and behaviors of college students on computerized simulations of high-stakes exams. Thirty-five college students with ADHD were compared to 185 typical…
Code of Federal Regulations, 2010 CFR
2010-10-01
... installation, operation, maintenance and enhancement of Computerized Tribal IV-D Systems and Office Automation... HEALTH AND HUMAN SERVICES COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.20 What are the conditions for funding the installation...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false Under what circumstances would emergency FFP be... AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.35 Under what circumstances would emergency FFP be available for Computerized Tribal IV-D Systems? (a...
ERIC Educational Resources Information Center
Lavy, Ilana
2006-01-01
This paper presents a description of the different types of arguments that emerged as two students, working in a computerized environment, engaged in an investigation of several number theory concepts. The emerging arguments are seen as a result of the influence of the computerized environment together with collaborative learning. Using…
Development of a Computerized In-Basket Exercise for the Classroom: A Sales Management Example
ERIC Educational Resources Information Center
Pearson, Michael M.; Barnes, John W.; Onken, Marina H.
2006-01-01
This article follows the development of a sales management in-basket exercise for use in the classroom. The authors have computerized the exercise and added features to allow for additional and more quantitative input from the students. The exercise has evolved and been tested in numerous classroom situations. The computerized in-basket exercise…
ERIC Educational Resources Information Center
Stansfield, Charles W., Ed.
This collection of essays on measurement theory and language testing includes: "Computerized Adaptive Testing: Implications for Language Test Developers" (Peter Tung); "The Promise and Threat of Computerized Adaptive Assessment of Reading Comprehension" (Michael Canale); "Computerized Rasch Analysis of Item Bias in ESL…
ERIC Educational Resources Information Center
Chang, Frank Tien-Jin
Computerized school administration has become one of the most crucial innovations in vocational education in Taiwan in the Republic of China. As these educators begin to design or purchase computerized information systems for their own schools, they must first define their specific information needs. Next, they should pay attention to…
Assessment Outcomes: Computerized Instruction in a Human Gross Anatomy Course.
ERIC Educational Resources Information Center
Bukowski, Elaine L.
2002-01-01
The first of three successive classes of beginning physical therapy students (n=17) completed traditional cadaver anatomy lecture/lab; the next 17 a self-study computerized anatomy lab, and the next 20 both lectures and computer lab. No differences in study times and course or licensure exam performance appeared. Computerized self-study is a…
Magazine, Rahul; Mohapatra, Aswini K.; Manu, Mohan K.; Srivastava, Rajendra K.
2011-01-01
A 22-year-old unmarried man presented to the chest outpatient department with a history of productive cough of two-month duration. He also complained of pain and swelling on the anterior aspect of right side of chest of one-month duration. Imaging studies of the thorax, including chest roentgenography and computerized tomography, revealed an unruptured lung abscess which had herniated into the chest wall. Culture of pus aspirated from the chest wall swelling grew Mycobacterium tuberculosis. He was diagnosed to have a tuberculous lung abscess which had extended into the chest wall, without spillage into the pleural cavity or the bronchial tree. Antituberculosis drugs were prescribed, and he responded to the treatment with complete resolution of the lesion. PMID:22084547
A randomized controlled trial of the Cool Teens CD-ROM computerized program for adolescent anxiety.
Wuthrich, Viviana M; Rapee, Ronald M; Cunningham, Michael J; Lyneham, Heidi J; Hudson, Jennifer L; Schniering, Carolyn A
2012-03-01
Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This paper describes the results of a small randomized controlled trial of the Cool Teens program for adolescent anxiety, and examines potential barriers to treatment and user preferences of computerized technology in this population. Forty-three adolescents with a primary diagnosis of anxiety were randomly allocated to the Cool Teens program, a 12-week computerized cognitive-behavioral therapy program for anxiety management, or a 12-week wait list. Effects on symptoms, negative thoughts, and life interference were assessed at post-treatment and 3-month follow-up, based on diagnosis as well as self and maternal report. Using mixed-model analyses, at post-treatment and follow-up assessments, adolescents in the Cool Teens condition, compared with those on the wait list, were found to have significant reductions in the total number of anxiety disorders, the severity of the primary anxiety disorder, and the average severity for all disorders. These results were matched by significant reductions in mother and child questionnaire reports of anxiety, internalizing symptoms, automatic thoughts, and life interference. Further few barriers to treatment were found, and user preferences indicated that the computerized treatment was well suited to adolescents with anxiety. The Cool Teens program is efficacious for treatment of adolescent anxiety. Clinical trial registration information-A randomized controlled trial of the Cool Teens computerized program for anxious adolescents compared with waist list; http://www.anzctr.org.au; ACTRN12611000508976. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.
McCarthy, Jillian H.; Hogan, Tiffany P.; Beukelman, David R.; Schwarz, Ilsa E.
2015-01-01
Purpose Spelling is an important skill for individuals who rely on augmentative alternative communication (AAC). The purpose of this study was to investigate how computerized sounding out influenced spelling accuracy of pseudo-words. Computerized sounding out was defined as a word elongated, thus providing an opportunity for a child to hear all the sounds in the word at a slower rate. Methods Seven children with cerebral palsy, four who use AAC and three who do not, participated in a single subject AB design. Results The results of the study indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words produced by participants. Conclusion The study provides preliminary evidence for the use of computerized sounding out during spelling tasks for children with cerebral palsy who do and do not use AAC. Future directions and clinical implications are discussed. PMID:24512195
Code of Federal Regulations, 2014 CFR
2014-10-01
... comprehensive Tribal IV-D agencies must have in place to ensure the security and privacy of Computerized Tribal... ensure the security and privacy of Computerized Tribal IV-D Systems and Office Automation? (a..., accuracy, completeness, access to, and use of data in the Computerized Tribal IV-D System and Office...
ERIC Educational Resources Information Center
Hol, A. Michiel; Vorst, Harrie C. M.; Mellenbergh, Gideon J.
2007-01-01
In a randomized experiment (n = 515), a computerized and a computerized adaptive test (CAT) are compared. The item pool consists of 24 polytomous motivation items. Although items are carefully selected, calibration data show that Samejima's graded response model did not fit the data optimally. A simulation study is done to assess possible…
ERIC Educational Resources Information Center
Skinner, Harvey A.; Allen, Barbara A.
1983-01-01
Compared histories of alcohol, drug, and tobacco use obtained by computerized interview, face-to-face interview, and self-report in clients (N=150) from an addiction treatment center. Multivariate analyses revealed no important differences. The computerized interview was rated less friendly but faster and more interesting. (Author/JAC)
ERIC Educational Resources Information Center
Vispoel, Walter P.; Boo, Jaeyool; Bleiler, Timothy
2001-01-01
Evaluated the characteristics of computerized and paper-and-pencil versions of the Rosenberg Self-Esteem Scale (SES) using scores for 224 college students. Results show that mode of administration has little effect on the psychometric properties of the SES although the computerized version took longer and was preferred by examinees. (SLD)
Overton, Edgar Turner; Kauwe, John S.K.; Paul, Rob; Tashima, Karen; Tate, David F.; Patel, Pragna; Carpenter, Chuck; Patty, David; Brooks, John T.; Clifford, David B
2013-01-01
HIV-associated neurocognitive disorders (HAND) remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (p<0.01). These data confirm previous correlation data with the computerized battery, yet illustrate remaining challenges for neurocognitive screening. PMID:21877204
Schulenberg, S E; Yutrzenka, B A
1999-05-01
The use of computerized psychological assessment is a growing practice among contemporary mental health professionals. Many popular and frequently used paper-and-pencil instruments have been adapted into computerized versions. Although equivalence for many instruments has been evaluated and supported, this issue is far from resolved. This literature review deals with recent research findings that suggest that computer aversion negatively impacts computerized assessment, particularly as it relates to measures of negative affect. There is a dearth of equivalence studies that take into account computer aversion's potential impact on the measurement of negative affect. Recommendations are offered for future research in this area.
Computerized symbolic manipulation in structural mechanics Progress and potential
NASA Technical Reports Server (NTRS)
Noor, A. K.; Andersen, C. M.
1978-01-01
Status and recent applications of computerized symbolic manipulation to structural mechanics problems are summarized. The applications discussed include; (1) generation of characteristic arrays of finite elements; (2) evaluation of effective stiffness and mass coefficients of continuum models for repetitive lattice structures; and (3) application of Rayleigh-Ritz technique to free vibration analysis of laminated composite elliptic plates. The major advantages of using computerized symbolic manipulation in each of these applications are outlined. A number of problem areas which limit the realization of the full potential of computerized symbolic manipulation in structural mechanics are examined and some of the means of alleviating them are discussed.
Pollard, Robert Q; Sutter, Erika; Cerulli, Catherine
2014-01-01
A computerized sign language survey was administered to two large samples of deaf adults. Six questions regarding intimate partner violence (IPV) were included, querying lifetime and past-year experiences of emotional abuse, physical abuse, and forced sex. Comparison data were available from a telephone survey of local households. Deaf respondents reported high rates of emotional abuse and much higher rates of forced sex than general population respondents. Physical abuse rates were comparable between groups. More men than women in both deaf samples reported past-year physical and sexual abuse. Past-year IPV was associated with higher utilization of hospital emergency services. Implications for IPV research, education, and intervention in the Deaf community are discussed. PMID:24142445
Serving up Success: A Recipe for Turning a Profit.
ERIC Educational Resources Information Center
Cline, Tami; Fitzgerald, Patricia L.
1997-01-01
Due to shrinking financial resources accompanied by increased nutritional responsibilities, school food service professionals are employing economies of scale (central kitchens, cooperative purchasing, computerization, and high-tech food preparation equipment) and revenue-expansion opportunities (catering, vending machines, and "a la…
Three-dimensional evaluation of the facet joints
NASA Astrophysics Data System (ADS)
Folio, Les R.
1990-04-01
Computerized tomography and magnetic resonance imaging nave revolurionalized analysis of vertebral anatomy and pathology. Further advances with 3-dimensional imaging have recently become an important adjunct for diagnosis and treatment in structural abnormalities. Facets are intimately related to their surrounding musculature and malalignment may cause pain directly or indirectly. High resolution 3-dimensional reformations of CT Scans give us new insight on structure and function of facet joints, since their motion and architecture are ever complex. It is well documented in the literature that facet joint biomecnanics is a partial contributor to the myriad at causes of low back The term "facet Joint syndrome" was coined in 1933 by GhorMley.3 The osteopathic lesion complex is well defined by LeRoy and McCole and comparison of roentgenographic findings before and after manipulation has teen described by Long and Lioyd.4,5 since alterations in facet biamechanics are an important aspect of osteopathic manipulative therapy (OT), 3-dimensional hign resolution imaging will prove to be a great asset in osteopathic research. Rotating the spine allows for different viewing perspectives to provide optimal and consistent measurements of the facet joint. Rotations are performed on the X, Y and 7, axis and measurements pre and post-manipulation are performed and compared on matching axis and perspectives. Rotation about the X, Y and Z axis help appreciate the 3-dimensionality of the vertebral column to project to the viewer a feeling that the spine is floating in space before them. This does give the viewer a 3-D understanding of the object however, only at a perspective at a Lime.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false Under what circumstances would FFP be suspended or... SYSTEMS AND OFFICE AUTOMATION Funding for Computerized Tribal IV-D Systems and Office Automation § 310.30 Under what circumstances would FFP be suspended or disallowed in the costs of Computerized Tribal IV-D...
Computerized Biomechanical Man-Model
1976-07-01
Force Systems Command Wright-Patterson AFB, Ohio ABSTRACT The COMputerized BIomechanical MAN-Model (called COMBIMAN) is a computer interactive graphics...concept was to build a mock- The use of mock-ups for biomechanical evalua- up which permitted the designer to visualize the tion has long been a tool...of the can become an obstacle to design change. Aerospace Medical Research Laboratory, we are developing a computerized biomechanical man-model
2010-10-01
facial trustworthiness; facial displays of anger) presented subliminally . Furthermore, the responsiveness of these regions to subliminal stimulation ...develop, or program the computerized stimulation paradigms for use during functional neuroimaging (i.e., MJT; BMAT; EFAT). These paradigms will be...programming began on the computerized functional MRI stimulation paradigms using e-prime software. • Quarter #2: Programming of all computerized functional
2017-10-01
AWARD NUMBER: W81XWH-15-1-0508 TITLE: Multimodal Intervention Trial for Cognitive Deficits in Neurofibromatosis Type 1: Efficacy of...Computerized Cognitive Training and Stimulant Medication PRINCIPAL INVESTIGATOR: Maria T. Acosta, M.D. CONTRACTING ORGANIZATION: Children’s National Health...database. 15. SUBJECT TERMS Neurofibromatosis, cognition , pediatric, computerized training programs, working memory 16. SECURITY CLASSIFICATION OF: 17
ERIC Educational Resources Information Center
Bennett, Stephanie J.; Holmes, Joni; Buckley, Sue
2013-01-01
This study evaluated the impact of a computerized visuospatial memory training intervention on the memory and behavioral skills of children with Down syndrome. Teaching assistants were trained to support the delivery of a computerized intervention program to individual children over a 10-16 week period in school. Twenty-one children aged 7-12…
ERIC Educational Resources Information Center
Carriedo, Ruben; And Others
The San Diego Unified School District (California) began operating a computerized routing and scheduling system for its pupil transportation services at the beginning of the 1985-86 academic school year. The computerized system, provided by Ecotran Systems, Inc. (ECO) of Cleveland, Ohio experienced an inordinate number of difficulties. A…
ERIC Educational Resources Information Center
National Center for Education Statistics (ED), Washington, DC.
These three users' manuals are for specific files of the High School and Beyond Study, a national longitudinal study of high school sophomores and seniors in 1980. The three files are computerized databases that are available on magnetic tape. As one component of base year data collection, information identifying twins, triplets, and some non-twin…
Webb, S M; Ruscalleda, J; Schwarzstein, D; Calaf-Alsina, J; Rovira, A; Matos, G; Puig-Domingo, M; de Leiva, A
1992-05-01
We wished to analyse the relative value of computerized tomography and magnetic resonance in patients referred for evaluation of pituitary and parasellar lesions. We performed a separate evaluation by two independent neuroradiologists of computerized tomography and magnetic resonance images ordered numerically and anonymously, with no clinical data available. We studied 40 patients submitted for hypothalamic-pituitary study; 31 were carried out preoperatively, of which histological confirmation later became available in 14. The remaining nine patients were evaluated postoperatively. Over 40 parameters relating to the bony margins, cavernous sinuses, carotid arteries, optic chiasm, suprasellar cisterns, pituitary, pituitary stalk and extension of the lesion were evaluated. These reports were compared with the initial ones offered when the scans were ordered, and with the final diagnosis. Concordance between initial computerized tomography and magnetic resonance was observed in 27 cases (67.5%); among the discordant cases computerized tomography showed the lesion in two, magnetic resonance in 10, while in the remaining case reported to harbour a microadenoma on computerized tomography the differential diagnosis between a true TSH-secreting microadenoma and pituitary resistance to thyroid hormones is still unclear. Both neuroradiologists coincided in their reports in 32 patients (80%); when the initial report was compared with those of the neuroradiologists, concordance was observed with at least one of them in 34 instances (85%). Discordant results were observed principally in microadenomas secreting ACTH or PRL and in delayed puberty. In the eight patients with Cushing's disease (histologically confirmed in six) magnetic resonance was positive in five and computerized tomography in two; the abnormal image correctly identified the side of the lesion at surgery. In patients referred for evaluation of Cushing's syndrome or hyperprolactinaemia (due to microadenomas) or after surgery, magnetic resonance is clearly preferable to computerized tomography. In macroadenomas both scans are equally diagnostic but magnetic resonance offers more information on pituitary morphology and neighbouring structures. Nevertheless, there are cases in which the results of computerized tomography and magnetic resonance will complement each other, since different parameters are analysed with each examination and discordant results are encountered.
ERIC Educational Resources Information Center
Gaither, Dick; Baker, John
An Indianapolis (Indiana) project gave disadvantaged junior high and high school students summer jobs in various departments of a Veterans' Administration hospital. The project combined work with at least 1 hour per day of computerized instruction in basic mathematics and language, work maturity, and specific job competencies. Rules were strict,…
ERIC Educational Resources Information Center
Makransky, Guido; Glas, Cees A. W.
2013-01-01
Cognitive ability tests are widely used in organizations around the world because they have high predictive validity in selection contexts. Although these tests typically measure several subdomains, testing is usually carried out for a single subdomain at a time. This can be ineffective when the subdomains assessed are highly correlated. This…
ERIC Educational Resources Information Center
Telem, M.
2005-01-01
The introduction of a school management information system (SMIS) in an urban vocational high school, located in a middle-class socio-economic neighborhood, notably affected the learning, behavior and attendance (LBA) interrelations between homeroom teachers (HRTs) and parents. HRT-parents interrelations in general, but those involving parents…
ERIC Educational Resources Information Center
Arendasy, Martin E.; Sommer, Markus
2012-01-01
The use of new test administration technologies such as computerized adaptive testing in high-stakes educational and occupational assessments demands large item pools. Classic item construction processes and previous approaches to automatic item generation faced the problems of a considerable loss of items after the item calibration phase. In this…
Computerized screening for cognitive impairment in patients with COPD
Campman, Carlijn; van Ranst, Dirk; Meijer, Jan Willem; Sitskoorn, Margriet
2017-01-01
Purpose COPD is associated with cognitive impairment. These impairments should be diagnosed, but due to time- and budget-reasons, they are often not investigated. The aim of this study is to examine the viability of a brief computerized cognitive test battery, Central Nervous System Vital Signs (CNSVS), in COPD patients. Patients and methods Patients with COPD referred to tertiary pulmonary rehabilitation were included. Cognitive functioning of patients was assessed with CNSVS before pulmonary rehabilitation and compared with age-corrected CNSVS norms. CNSVS is a 30 minute computerized test battery that includes tests of verbal and visual memory, psychomotor speed, processing speed, cognitive flexibility, complex attention, executive functioning, and reaction time. Results CNSVS was fully completed by 205 (93.2%, 105 females, 100 males) of the total group of patients (n=220, 116 females, 104 males). Z-tests showed that COPD patients performed significantly worse than the norms on all CNSVS cognitive domains. Slightly more than half of the patients (51.8%) had impaired functioning on 1 or more cognitive domains. Patients without computer experience performed significantly worse on CNSVS than patients using the computer frequently. Conclusion The completion rate of CNSVS was high and cognitive dysfunctions measured with this screening were similar to the results found in prior research, including paper and pen cognitive tests. These results support the viability of this brief computerized cognitive screening in COPD patients, that may lead to better care for these patients. Cognitive performance of patients with little computer experience should be interpreted carefully. Future research on this issue is needed. PMID:29089756
Computerized image analysis for quantitative neuronal phenotyping in zebrafish.
Liu, Tianming; Lu, Jianfeng; Wang, Ye; Campbell, William A; Huang, Ling; Zhu, Jinmin; Xia, Weiming; Wong, Stephen T C
2006-06-15
An integrated microscope image analysis pipeline is developed for automatic analysis and quantification of phenotypes in zebrafish with altered expression of Alzheimer's disease (AD)-linked genes. We hypothesize that a slight impairment of neuronal integrity in a large number of zebrafish carrying the mutant genotype can be detected through the computerized image analysis method. Key functionalities of our zebrafish image processing pipeline include quantification of neuron loss in zebrafish embryos due to knockdown of AD-linked genes, automatic detection of defective somites, and quantitative measurement of gene expression levels in zebrafish with altered expression of AD-linked genes or treatment with a chemical compound. These quantitative measurements enable the archival of analyzed results and relevant meta-data. The structured database is organized for statistical analysis and data modeling to better understand neuronal integrity and phenotypic changes of zebrafish under different perturbations. Our results show that the computerized analysis is comparable to manual counting with equivalent accuracy and improved efficacy and consistency. Development of such an automated data analysis pipeline represents a significant step forward to achieve accurate and reproducible quantification of neuronal phenotypes in large scale or high-throughput zebrafish imaging studies.
Virtual reality simulation: using three-dimensional technology to teach nursing students.
Jenson, Carole E; Forsyth, Diane McNally
2012-06-01
The use of computerized technology is rapidly growing in the classroom and in healthcare. An emerging computer technology strategy for nursing education is the use of virtual reality simulation. This computer-based three-dimensional educational tool simulates real-life patient experiences in a risk-free environment, allows for repeated practice sessions, requires clinical decision making, exposes students to diverse patient conditions, provides immediate feedback, and is portable. The purpose of this article was to review the importance of virtual reality simulation as a computerized teaching strategy. In addition, a project to explore readiness of nursing faculty at one major Midwestern university for the use of virtual reality simulation as a computerized teaching strategy is described where faculty thought virtual reality simulation would increase students' knowledge of an intravenous line insertion procedure. Faculty who practiced intravenous catheter insertion via virtual reality simulation expressed a wide range of learning experiences from using virtual reality simulation that is congruent with the literature regarding the barriers to student learning. Innovative teaching strategies, such as virtual reality simulation, address barriers of increasing patient acuity, high student-to-faculty ratio, patient safety concerns from faculty, and student anxiety and can offer rapid feedback to students.
Sensitive Fibre-Based Thermoluminescence Detectors for High Resolution In-Vivo Dosimetry
NASA Astrophysics Data System (ADS)
Ghomeishi, Mostafa; Mahdiraji, G. Amouzad; Adikan, F. R. Mahamd; Ung, N. M.; Bradley, D. A.
2015-08-01
With interest in the potential of optical fibres as the basis of next-generation thermoluminescence dosimeters (TLDs), the development of suitable forms of material and their fabrication has become a fast-growing endeavour. Present study focuses on three types of Ge-doped optical fibres with different structural arrangements and/or shapes, namely conventional cylindrical fibre, capillary fibre, and flat fibre, all fabricated using the same optical fibre preform. For doses from 0.5 to 8 Gy, obtained at electron and photon energies, standard thermoluminescence (TL) characteristics of the optical fibres have been the subject of detailed investigation. The results show that in collapsing the capillary fibre into a flat shape, the TL yield is increased by a factor of 5.5, the yield being also some 3.2 times greater than that of the conventional cylindrical fibre fabricated from the same perform. This suggests a means of production of suitably sensitive TLD for in-vivo dosimeter applications. Addressing the associated defects generating luminescence from each of the optical fibres, the study encompasses analysis of the TL glow curves, with computerized glow curve deconvolution (CGCD) and 2nd order kinetics.
Sensitive Fibre-Based Thermoluminescence Detectors for High Resolution In-Vivo Dosimetry.
Ghomeishi, Mostafa; Mahdiraji, G Amouzad; Adikan, F R Mahamd; Ung, N M; Bradley, D A
2015-08-28
With interest in the potential of optical fibres as the basis of next-generation thermoluminescence dosimeters (TLDs), the development of suitable forms of material and their fabrication has become a fast-growing endeavour. Present study focuses on three types of Ge-doped optical fibres with different structural arrangements and/or shapes, namely conventional cylindrical fibre, capillary fibre, and flat fibre, all fabricated using the same optical fibre preform. For doses from 0.5 to 8 Gy, obtained at electron and photon energies, standard thermoluminescence (TL) characteristics of the optical fibres have been the subject of detailed investigation. The results show that in collapsing the capillary fibre into a flat shape, the TL yield is increased by a factor of 5.5, the yield being also some 3.2 times greater than that of the conventional cylindrical fibre fabricated from the same perform. This suggests a means of production of suitably sensitive TLD for in-vivo dosimeter applications. Addressing the associated defects generating luminescence from each of the optical fibres, the study encompasses analysis of the TL glow curves, with computerized glow curve deconvolution (CGCD) and 2(nd) order kinetics.
An insight into morphometric descriptors of cell shape that pertain to regenerative medicine.
Lobo, Joana; See, Eugene Yong-Shun; Biggs, Manus; Pandit, Abhay
2016-07-01
Cellular morphology has recently been indicated as a powerful indicator of cellular function. The analysis of cell shape has evolved from rudimentary forms of microscopic visual inspection to more advanced methodologies that utilize high-resolution microscopy coupled with sophisticated computer hardware and software for data analysis. Despite this progress, there is still a lack of standardization in quantification of morphometric parameters. In addition, uncertainty remains as to which methodologies and parameters of cell morphology will yield meaningful data, which methods should be utilized to categorize cell shape, and the extent of reliability of measurements and the interpretation of the resulting analysis. A large range of descriptors has been employed to objectively assess the cellular morphology in two-dimensional and three-dimensional domains. Intuitively, simple and applicable morphometric descriptors are preferable and standardized protocols for cell shape analysis can be achieved with the help of computerized tools. In this review, cellular morphology is discussed as a descriptor of cellular function and the current morphometric parameters that are used quantitatively in two- and three-dimensional environments are described. Furthermore, the current problems associated with these morphometric measurements are addressed. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Sensitive Fibre-Based Thermoluminescence Detectors for High Resolution In-Vivo Dosimetry
Ghomeishi, Mostafa; Mahdiraji, G. Amouzad; Adikan, F. R. Mahamd; Ung, N. M.; Bradley, D. A.
2015-01-01
With interest in the potential of optical fibres as the basis of next-generation thermoluminescence dosimeters (TLDs), the development of suitable forms of material and their fabrication has become a fast-growing endeavour. Present study focuses on three types of Ge-doped optical fibres with different structural arrangements and/or shapes, namely conventional cylindrical fibre, capillary fibre, and flat fibre, all fabricated using the same optical fibre preform. For doses from 0.5 to 8 Gy, obtained at electron and photon energies, standard thermoluminescence (TL) characteristics of the optical fibres have been the subject of detailed investigation. The results show that in collapsing the capillary fibre into a flat shape, the TL yield is increased by a factor of 5.5, the yield being also some 3.2 times greater than that of the conventional cylindrical fibre fabricated from the same perform. This suggests a means of production of suitably sensitive TLD for in-vivo dosimeter applications. Addressing the associated defects generating luminescence from each of the optical fibres, the study encompasses analysis of the TL glow curves, with computerized glow curve deconvolution (CGCD) and 2nd order kinetics. PMID:26314683
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2011-01-01
A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.
Darling, M.E.; Hubbard, L.E.
1994-01-01
Computerized Geographic Information Systems (GIS) have become viable and valuable tools for managing,analyzing, creating, and displaying data for three-dimensional finite-difference ground-water flow models. Three GIS applications demonstrated in this study are: (1) regridding of data arrays from an existing large-area, low resolution ground-water model to a smaller, high resolution grid; (2) use of GIS techniques for assembly of data-input arrays for a ground-water model; and (3) use of GIS for rapid display of data for verification, for checking of ground-water model output, and for the cre.ation of customized maps for use in reports. The Walla Walla River Basin was selected as the location for the demonstration because (1) data from a low resolution ground-water model (Columbia Plateau Regional Aquifer System Analysis [RASA]) were available and (2) concern for long-term use of water resources for irrigation in the basin. The principal advantage of regridding is that it may provide the ability to more precisely calibrate a model, assuming chat a more detailed coverage of data is available, and to evaluate the numerical errors associated with a particular grid design.Regridding gave about an 8-fold increase in grid-node density.Several FORTRAN programs were developed to load the regridded ground-water data into a finite-difference modular model as model-compatible input files for use in a steady-state model run.To facilitate the checking and validating of the GIS regridding process, maps and tabular reports were produced for each of eight ground-water parameters by model layer. Also, an automated subroutine that was developed to view the model-calculated water levels in cross-section will aid in the synthesis and interpretation of model results.
Mixed results in the safety performance of computerized physician order entry.
Metzger, Jane; Welebob, Emily; Bates, David W; Lipsitz, Stuart; Classen, David C
2010-04-01
Computerized physician order entry is a required feature for hospitals seeking to demonstrate meaningful use of electronic medical record systems and qualify for federal financial incentives. A national sample of sixty-two hospitals voluntarily used a simulation tool designed to assess how well safety decision support worked when applied to medication orders in computerized order entry. The simulation detected only 53 percent of the medication orders that would have resulted in fatalities and 10-82 percent of the test orders that would have caused serious adverse drug events. It is important to ascertain whether actual implementations of computerized physician order entry are achieving goals such as improved patient safety.
Information technology and medication safety: what is the benefit?
Kaushal, R; Bates, D
2002-01-01
Medication errors occur frequently and have significant clinical and financial consequences. Several types of information technologies can be used to decrease rates of medication errors. Computerized physician order entry with decision support significantly reduces serious inpatient medication error rates in adults. Other available information technologies that may prove effective for inpatients include computerized medication administration records, robots, automated pharmacy systems, bar coding, "smart" intravenous devices, and computerized discharge prescriptions and instructions. In outpatients, computerization of prescribing and patient oriented approaches such as personalized web pages and delivery of web based information may be important. Public and private mandates for information technology interventions are growing, but further development, application, evaluation, and dissemination are required. PMID:12486992
Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu
2009-10-01
The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.
ERIC Educational Resources Information Center
Benzie, Tim
1997-01-01
Describes the use of a computerized roof management system (CRMS) for school districts to foster multiple roof maintenance efficiency and cost effectiveness. Highlights CRMS software manufacturer choices, as well as the types of nondestructive testing equipment tools that can be used to evaluate roof conditions. (GR)
Growth and yield models for central hardwoods
Martin E. Dale; Donald E. Hilt
1989-01-01
Over the last 20 years computers have become an efficient tool to estimate growth and yield. Computerized yield estimates vary from simple approximation or interpolation of traditional normal yield tables to highly sophisticated programs that simulate the growth and yield of each individual tree.
ERIC Educational Resources Information Center
Al Sarhan, Khaled Ali; AlZboon, Saleem Odeh; Olimat, Khalaf Mufleh; Al-Zboon, Mohammad Saleem
2013-01-01
The study aims at introducing the features of the computerized educational games in sciences at the elementary school in Jordan according to the specialists in teaching science and computer subjects, through answering some questions such as: What are the features of the computerized educational games in sciences at the elementary schools in Jordan…
ERIC Educational Resources Information Center
Schumaker, Jean B.; Fisher, Joseph B.; Walsh, Lisa D.
2010-01-01
Effects of a computerized professional development (PD) program were investigated in two studies. For each, teachers were randomly assigned to either a Virtual Workshop (VW) group that used a computerized program for PD or to an Actual Workshop (AW) group that participated in a live PD session. In Study 1, the teachers' knowledge about and…
2009-01-01
Current care guidelines recommend glucose control (GC) in critically ill patients. To achieve GC, many ICUs have implemented a (nurse-based) protocol on paper. However, such protocols are often complex, time-consuming, and can cause iatrogenic hypoglycemia. Computerized glucose regulation protocols may improve patient safety, efficiency, and nurse compliance. Such computerized clinical decision support systems (Cuss) use more complex logic to provide an insulin infusion rate based on previous blood glucose levels and other parameters. A computerized CDSS for glucose control has the potential to reduce overall workload, reduce the chance of human cognitive failure, and improve glucose control. Several computer-assisted glucose regulation programs have been published recently. In order of increasing complexity, the three main types of algorithms used are computerized flowcharts, Proportional-Integral-Derivative (PID), and Model Predictive Control (MPC). PID is essentially a closed-loop feedback system, whereas MPC models the behavior of glucose and insulin in ICU patients. Although the best approach has not yet been determined, it should be noted that PID controllers are generally thought to be more robust than MPC systems. The computerized Cuss that are most likely to emerge are those that are fully a part of the routine workflow, use patient-specific characteristics and apply variable sampling intervals. PMID:19849827
Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.
Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S
2015-01-01
Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.
Rangé, G; Chassaing, S; Marcollet, P; Saint-Étienne, C; Dequenne, P; Goralski, M; Bardiére, P; Beverilli, F; Godillon, L; Sabine, B; Laure, C; Gautier, S; Hakim, R; Albert, F; Angoulvant, D; Grammatico-Guillon, L
2018-05-01
To assess the reliability and low cost of a computerized interventional cardiology (IC) registry to prospectively and systematically collect high-quality data for all consecutive coronary patients referred for coronary angiogram or/and coronary angioplasty. Rigorous clinical practice assessment is a key factor to improve prognosis in IC. A prospective and permanent registry could achieve this goal but, presumably, at high cost and low level of data quality. One multicentric IC registry (CRAC registry), fully integrated to usual coronary activity report software, started in the centre Val-de-Loire (CVL) French region in 2014. Quality assessment of CRAC registry was conducted on five IC CathLab of the CVL region, from January 1st to December 31st 2014. Quality of collected data was evaluated by measuring procedure exhaustivity (comparing with data from hospital information system), data completeness (quality controls) and data consistency (by checking complete medical charts as gold standard). Cost per procedure (global registry operating cost/number of collected procedures) was also estimated. CRAC model provided a high-quality level with 98.2% procedure completeness, 99.6% data completeness and 89% data consistency. The operating cost per procedure was €14.70 ($16.51) for data collection and quality control, including ST-segment elevation myocardial infarction (STEMI) preadmission information and one-year follow-up after angioplasty. This integrated computerized IC registry led to the construction of an exhaustive, reliable and costless database, including all coronary patients entering in participating IC centers in the CVL region. This solution will be developed in other French regions, setting up a national IC database for coronary patients in 2020: France PCI. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P
2008-07-01
Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.
The use of microtomography in bone tissue and biomaterial three-dimensional analysis.
Bedini, Rossella; Meleo, Deborah; Pecci, Raffaella; Pacifici, Luciano
2009-01-01
X-ray computed microtomography (micro-CT, microComputerised Tomography) is a miniaturized form of conventional computerized axial tomography (CAT ). This sophisticated technology enables 3D riconstruction of the internal structure of small X-ray opaque objects without sample destruction or preparation. The aim of this study is to show the possible applications of micro-CT in the analysis of bone graft materials of different origins (i.e. homologous, heterologous, alloplastic) in order to define their morphometric properties by means of SkyScan 1072 3D microtomography system. Since there is a close relationship between the properties of the materials and their microstructure, it is necessary to examine them using the highest levels of resolution before being able to improve existing materials or create new products.
Microcomputer Network for Computerized Adaptive Testing (CAT): Program Listing. Supplement.
1984-03-01
UMICROCOMPUTER NETWORK FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ): PROGRAM LISTING in APPROVED FOR PUBLIC RELEASE;IDISTRIBUTION UNLIMITEDPs DTIC ’ Akf 3 0 1-d84...NETWORK FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ).- PROGRAM LISTING , ,j Baldwin Quan Thomas A. Park Gary Sandahl John H. Wolfe Reviewed by James R. McBride A...Center San Diego, California 92152 V.% :-, CONTENTrS Page CATPROJECT.TEXT CAT system driver textfile I 1 ADMINDIR- Subdirectory - Test administration
Computerized Adaptive Screening Test (CAST): Development for Use in Military Recruiting Stations
1984-01-01
testing ( CAT ) 20. ABSTRACT (Continuo on rover .. efdo II neco .. ., ond Identity bJ’ 11/oclr -llor) The Computerized Adaptive Screening Test (CAST...effort is in progress to develop a computerized adaptive testing ( CAT ) system and to evaluate its potential for use in the military entrance...U.S. Marine Corps) has been designated as lead service for CAT system development; and the Navy Personnel Research and Development Center, as lead
Application of a computerized environmental information system to master and sector planning
NASA Technical Reports Server (NTRS)
Stewart, J. C.
1978-01-01
A computerized composite mapping system developed as an aid in the land use decision making process is described. Emphasis is placed on consideration of the environment in urban planning. The presence of alluvium, shallow bedrock, surface water, and vegetation growth are among the environmental factors considered. An analysis of the Shady Grove Sector planning is presented as an example of the use of computerized composite mapping for long range planning.
NASA Technical Reports Server (NTRS)
Maiocco, F. R.; Hume, J. P.
1976-01-01
A system's approach is outlined in the paper to assist facility and Plant Engineers improve their organization's data management system. The six basic steps identified may appear somewhat simple; however, adequate planning, proper resources, and the involvement of management will determine the success of a computerized facility management data base. Helpful suggestions are noted throughout the paper to insure the development of a practical computerized data management system.
ERIC Educational Resources Information Center
Kern, Joanne F.
The lack of opportunity for high school sophomores to learn database searching was addressed by the implementation of a computerized magazine article search program. "Reader's Guide to Periodical Literature" on CD-ROM was used to train students in database searching during the time they were assigned to the library to do research papers…
ERIC Educational Resources Information Center
Barnea, Nitza; Dori, Yehudit Judy; Hofstein, Avi
2010-01-01
Reforms in science education in general and in chemistry education in particular have been introduced in many countries since the beginning of the 21st Century. Similarly, at this time in Israel both the content and pedagogy of the chemistry curriculum in high schools were reformed. New content and pedagogical standards emerged, fostering…
Test-Taking Skills of High School Students with and without Learning Disabilities
ERIC Educational Resources Information Center
Lewandowski, Lawrence J.; Berger, Cassie; Lovett, Benjamin J.; Gordon, Michael
2016-01-01
This study assessed the test-taking skills of 776 high school students, 35 of whom were diagnosed with learning disabilities (LD). Students completed a computerized battery of timed reading tests as well as scales that assess test anxiety and test-taking perceptions. Students with LD obtained lower scores than the nondisabled group on all of the…
Chapurlat, Roland; Pialat, Jean-Baptiste; Merle, Blandine; Confavreux, Elisabeth; Duvert, Florence; Fontanges, Elisabeth; Khacef, Farida; Peres, Sylvie Loiseau; Schott, Anne-Marie; Lespessailles, Eric
2017-12-27
The diagnostic performance of densitometry is inadequate. New techniques of non-invasive evaluation of bone quality may improve fracture risk prediction. Testing the value of these techniques is the goal of the QUALYOR cohort. The bone mineral density (BMD) of postmenopausal women who sustain osteoporotic fracture is generally above the World Health Organization definition for osteoporosis. Therefore, new approaches to improve the detection of women at high risk for fracture are warranted. We have designed and recruited a new cohort to assess the predictive value of several techniques to assess bone quality, including high-resolution peripheral quantitative computerized tomography (HRpQCT), hip QCT, calcaneus texture analysis, and biochemical markers. We have enrolled 1575 postmenopausal women, aged at least 50, with an areal BMD femoral neck or lumbar spine T-score between - 1.0 and - 3.0. Clinical risk factors for fracture have been collected along with serum and blood samples. We describe the design of the QUALYOR study. Among these 1575 women, 80% were aged at least 60. The mean femoral neck T-score was - 1.6 and the mean lumbar spine T-score was -1.2. This cohort is currently being followed up. QUALYOR will provide important information on the relationship between bone quality variables and fracture risk in women with moderately decreased BMD.
Automatic Lemmatization in Serbo-Croatian.
ERIC Educational Resources Information Center
Spraycar, Rudy S.
1980-01-01
Discusses problems of lemmatization encountered by lexicographers and concordance-makers with highly inflected languages such as Serbo-Croatian and recommends the use of the computer in classifying individual works by dictionary-entry form. Suggests that computerized stylistic scanning of large literary databases is necessary to test the…
Netlearning and Learning through Networks
ERIC Educational Resources Information Center
Wiberg, Mikael
2007-01-01
Traditional non-computerized learning environments are typically founded on an understanding of learning as acquiring silence for an effective "individual learning process". Recently, it has also been reported that the high expectations for the impact of computer-based technology on educational practice have not been realized. This paper…
Albuquerque, Marco Antonio; Gaia, Bruno Felipe; Cavalcanti, Marcelo Gusmão Paraíso
2011-08-01
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. Copyright © 2011 Mosby, Inc. All rights reserved.
Flens, Gerard; Smits, Niels; Terwee, Caroline B; Dekker, Joost; Huijbrechts, Irma; Spinhoven, Philip; de Beurs, Edwin
2017-12-01
We used the Dutch-Flemish version of the USA PROMIS adult V1.0 item bank for Anxiety as input for developing a computerized adaptive test (CAT) to measure the entire latent anxiety continuum. First, psychometric analysis of a combined clinical and general population sample ( N = 2,010) showed that the 29-item bank has psychometric properties that are required for a CAT administration. Second, a post hoc CAT simulation showed efficient and highly precise measurement, with an average number of 8.64 items for the clinical sample, and 9.48 items for the general population sample. Furthermore, the accuracy of our CAT version was highly similar to that of the full item bank administration, both in final score estimates and in distinguishing clinical subjects from persons without a mental health disorder. We discuss the future directions and limitations of CAT development with the Dutch-Flemish version of the PROMIS Anxiety item bank.
Sehlen, Susanne; Ott, Martin; Marten-Mittag, Birgitt; Haimerl, Wolfgang; Dinkel, Andreas; Duehmke, Eckhart; Klein, Christian; Schaefer, Christof; Herschbach, Peter
2012-07-01
This study investigated feasibility and acceptance of computer-based assessment for the identification of psychosocial distress in routine radiotherapy care. 155 cancer patients were assessed using QSC-R10, PO-Bado-SF and Mach-9. The congruence between computerized tablet PC and conventional paper assessment was analysed in 50 patients. The agreement between the 2 modes was high (ICC 0.869-0.980). Acceptance of computer-based assessment was very high (>95%). Sex, age, education, distress and Karnofsky performance status (KPS) did not influence acceptance. Computerized assessment was rated more difficult by older patients (p = 0.039) and patients with low KPS (p = 0.020). 75.5% of the respondents supported referral for psycho-social intervention for distressed patients. The prevalence of distress was 27.1% (QSC-R10). Computer-based assessment allows easy identification of distressed patients. Level of staff involvement is low, and the results are quickly available for care providers. © Georg Thieme Verlag KG Stuttgart · New York.
Gerencser, Kristina R; Higbee, Thomas S; Akers, Jessica S; Contreras, Bethany P
2017-07-01
Training parents of children with autism spectrum disorder can be a challenge due to limited resources, time, and money. Interactive computerized training (ICT)-a self-paced program that incorporates instructions, videos, and interactive questions-is one method professionals can use to disseminate trainings to broader populations. This study extends previous research on ICT by assessing the effect of ICT to teach three parents how to implement a photographic activity schedule using a systematic prompting procedure with their child. Following ICT, all parents increased their fidelity to implementation of an activity schedule during role-play sessions with an adult. Fidelity remained high during implementation with their child and maintained during a 2-week follow-up. © 2017 Society for the Experimental Analysis of Behavior.
Sensorimotor Learning in a Computerized Athletic Training Battery.
Krasich, Kristina; Ramger, Ben; Holton, Laura; Wang, Lingling; Mitroff, Stephen R; Gregory Appelbaum, L
2016-01-01
Sensorimotor abilities are crucial for performance in athletic, military, and other occupational activities, and there is great interest in understanding learning in these skills. Here, behavioral performance was measured over three days as twenty-seven participants practiced multiple sessions on the Nike SPARQ Sensory Station (Nike, Inc., Beaverton, Oregon), a computerized visual and motor assessment battery. Wrist-worn actigraphy was recorded to monitor sleep-wake cycles. Significant learning was observed in tasks with high visuomotor control demands but not in tasks of visual sensitivity. Learning was primarily linear, with up to 60% improvement, but did not relate to sleep quality in this normal-sleeping population. These results demonstrate differences in the rate and capacity for learning across perceptual and motor domains, indicating potential targets for sensorimotor training interventions.
Gómez Palacios, Angel; Gómez Zábala, Jesús; Gutiérrez, María Teresa; Expósito, Amaya; Barrios, Borja; Zorraquino, Angel; Taibo, Miguel Angel; Iturburu, Ignacio
2006-12-01
1. To assess the sensitivity of scintigraphy using methoxy isobutyl isonitrile (MIBI). 2. To compare its resolution with that of ultrasound (US) and computerized axial tomography (CAT). 3. To use its diagnostic reliability to determine whether selective approaches can be used to treat hyperparathyroidism (HPT). A study of 76 patients who underwent surgery for HPT between 1996 and 2005 was performed. MIBI scintigraphy and cervical US were used for whole-body scanning in all patients; CAT was used in 47 patients. Intraoperative and postoperative biopsies were used for final evaluation of the tests, after visualization and surgical extirpation. The results of scintigraphy were positive in 65 patients (85.52%). The diagnosis was correct in all of the single images. Multiple images were due to hyperplasia and parathyroid adenomas with thyroid disease (5.2%). Three images, incorrectly classified as negative (3.94%), were positive. The sensitivity of US was 63% and allowed detection of three MIBI-negative adenomas (4%). CAT was less sensitive (55%), but detected a further three MIBI-negative adenomas (4%). 1. The sensitivity of MIBI reached 89.46%. In the absence of thyroid nodules, MIBI diagnosed 100% of single lesions. Pathological thyroid processes produced false-positive results (5.2%) and there were diagnostic errors (4%). 2. MIBI scintigraphy was more sensitive than US and CAT. 3. Positive, single image scintigraphy allows a selective cervical approach. US and CAT may help to save a further 8% of patients (with negative scintigraphy).
Nemanic, Sarah; Mills, Serena; Viehdorfer, Matt; Clark, Terri; Bailey, Mike
Teaching the anatomy of the canine larynx and hyoid apparatus is challenging because dissection disassembles and/or damages these structures, making it difficult to understand their three-dimensional (3D) anatomy and spatial interrelationships. This study assessed the effectiveness of an interactive, computerized 3D tutorial for teaching the anatomy of the canine larynx and hyoid apparatus using a randomized control design with students enrolled in the first-year professional program at Oregon State University College of Veterinary Medicine. All first-year students from 2 consecutive years were eligible. All students received the traditional methods of didactic teaching and dissection to learn the anatomy of the canine larynx and hyoid apparatus, after which they were divided into two statistically equal groups based on their cumulative anatomy test scores from the prior term. The tutorial group received an interactive, computerized tutorial developed by the investigators containing 3D images of the canine larynx and hyoid apparatus, while the control group received the same 3D images without the computerized tutorial. Both groups received the same post-learning assessment and survey. Sixty-three first-year students participated in the study, 28 in the tutorial group, and 35 in the control group. Post-learning assessment and survey scores were both significantly higher among students in the computerized tutorial group than those in the control group. This study demonstrates that a 3D computerized tutorial is more effective in teaching the anatomy of the canine hyoid apparatus and larynx than 3D images without a tutorial. Students likewise rated their learning experience higher when using the 3D computerized tutorial.
An Analysis of Minimum System Requirements to Support Computerized Adaptive Testing.
1986-09-01
adaptive test ( CAT ); adaptive test ing A;4SRAC:’ (Continue on reverie of necessary and ident4f by block number) % This pape-r discusses the minimum system...requirements needed to develop a computerized adaptive test ( CAT ). It lists some of the benefits of adaptive testing, establishes a set of...discusses the minimum system requirements needed to develop a computerized adaptive test ( CAT ). It lists some of the benefits of adaptive testing
ERIC Educational Resources Information Center
Payne, Arnold, Comp.
This publication presents performance flow charts and other accompanying forms that are elements of an economical computerized continuing inventory system. The system described here is intended to serve school systems as an adequate fixed asset system and to provide a computerized inventory model that offers support for costs of future educational…
1986-09-01
differentiation between the systems. This study will investigate an appropriate Order Processing and Management Information System (OP&MIS) to link base-level...methodology: 1. Reviewed the current order processing and information model of the TUAF Logistics System. (centralized-manual model) 2. Described the...RDS program’s order processing and information system. (centralized-computerized model) 3. Described the order irocessing and information system of
Computerized proof techniques for undergraduates
NASA Astrophysics Data System (ADS)
Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu
2012-12-01
The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete mathematics. We demonstrate by examples how one can use these computerized proof techniques to raise students' interests in the discovery and proof of mathematical identities and enhance their problem-solving skills.
NASA Technical Reports Server (NTRS)
Rumbaugh, Duane M.; Washburn, David A.; Savage-Rumbaugh, E. S.; Hopkins, William D.; Richardson, W. K.
1991-01-01
Automation of a computerized test system for comparative primate research is shown to improve the results of learning in standard paradigms. A mediational paradigm is used to determine the degree to which criterion in the learning-set testing reflects stimulus-response associative or mediational learning. Rhesus monkeys are shown to exhibit positive transfer as the criterion levels are shifted upwards, and the effectiveness of the computerized testing system is confirmed.
Theiler, R; Spielberger, J; Bischoff, H A; Bellamy, N; Huber, J; Kroesen, S
2002-06-01
The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects. The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. Copyright 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
Laloyaux, Julien; Van der Linden, Martial; Levaux, Marie-Noëlle; Mourad, Haitham; Pirri, Anthony; Bertrand, Hervé; Domken, Marc-André; Adam, Stéphane; Larøi, Frank
2014-07-30
Difficulties in everyday life activities are core features of persons diagnosed with schizophrenia and in particular during multitasking activities. However, at present, patients׳ multitasking capacities have not been adequately examined in the literature due to the absence of suitable assessment strategies. We thus recently developed a computerized real-life activity task designed to take into account the complex and multitasking nature of certain everyday life activities where participants are required to prepare a room for a meeting. Twenty-one individuals diagnosed with schizophrenia and 20 matched healthy controls completed the computerized task. Patients were also evaluated with a cognitive battery, measures of symptomatology and real world functioning. To examine the ecological validity, 14 other patients were recruited and were given the computerized version and a real version of the meeting preparation task. Results showed that performance on the computerized task was significantly correlated with executive functioning, pointing to the major implication of these cognitive processes in multitasking situations. Performance on the computerized task also significantly predicted up to 50% of real world functioning. Moreover, the computerized task demonstrated good ecological validity. These findings suggest the importance of evaluating multitasking capacities in patients diagnosed with schizophrenia in order to predict real world functioning. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Computerized photogrammetry used to calculate the brow position index.
Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako
2012-10-01
The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.
Computerized Maze Navigation and On-Road Performance by Drivers With Dementia
Ott, Brian R.; Festa, Elena K.; Amick, Melissa M.; Grace, Janet; Davis, Jennifer D.; Heindel, William C.
2012-01-01
This study examined the ability of computerized maze test performance to predict the road test performance of cognitively impaired and normal older drivers. The authors examined 133 older drivers, including 65 with probable Alzheimer disease, 23 with possible Alzheimer disease, and 45 control subjects without cognitive impairment. Subjects completed 5 computerized maze tasks employing a touch screen and pointer as well as a battery of standard neuropsychological tests. Parameters measured for mazes included errors, planning time, drawing time, and total time. Within 2 weeks, subjects were examined by a professional driving instructor on a standardized road test modeled after the Washington University Road Test. Road test total score was significantly correlated with total time across the 5 mazes. This maze score was significant for both Alzheimer disease subjects and control subjects. One maze in particular, requiring less than 2 minutes to complete, was highly correlated with driving performance. For the standard neuropsychological tests, highest correlations were seen with Trail Making A (TrailsA) and the Hopkins Verbal Learning Tests Trial 1 (HVLT1). Multiple regression models for road test score using stepwise subtraction of maze and neuropsychological test variables revealed significant independent contributions for total maze time, HVLT1, and TrailsA for the entire group; total maze time and HVLT1 for Alzheimer disease subjects; and TrailsA for normal subjects. As a visual analog of driving, a brief computerized test of maze navigation time compares well to standard neuropsychological tests of psychomotor speed, scanning, attention, and working memory as a predictor of driving performance by persons with early Alzheimer disease and normal elders. Measurement of maze task performance appears to be useful in the assessment of older drivers at risk for hazardous driving. PMID:18287166
Nayak, Madhabika B; Korcha, Rachael A; Kaskutas, Lee A; Kaskustas, Lee A; Avalos, Lyndsay A
2014-11-25
Recommended screening and brief intervention (SBI) for alcohol use during pregnancy is impeded by high patient loads and limited resources in public health settings. We evaluated the feasibility, acceptability and validity of a new self-administered, single-session, bilingual, computerized Screening and Brief Intervention (SBI) program for alcohol and sugar sweetened beverage (SSB) use in pregnancy. We developed and tested the computerized SBI program at a public health clinic with 290 pregnant women. Feasibility, acceptability, and validity measures were included in the program which had several modules, including those on demographics, health and beverage use. Time to complete the program and user experience items were used to determine program feasibility and acceptability. Validity analyses compared proportions of prenatal alcohol use identified by the program versus in-person screening by clinic staff. Most program users (87%, n = 251) completed the entire program; 91% (n = 263) completed the key screening and brief intervention modules. Most users also completed the program in ten to fifteen minutes. Program users reported that the program was easy to use (97%), they learned something new (88%), and that they would share what they learned with others (83%) and with their doctors or clinic staff (76%). Program acceptability did not differ by age, education, or type of beverage intervention received. The program identified alcohol use in pregnancy among 21% of users, a higher rate than the 13% (p < .01) found via screening by clinic staff. Computerized Screening and Brief Intervention for alcohol and SSB use in public health clinics is feasible and acceptable to English and Spanish speaking pregnant women and can efficiently identify prenatal alcohol use.
Surface mapping of spike potential fields: experienced EEGers vs. computerized analysis.
Koszer, S; Moshé, S L; Legatt, A D; Shinnar, S; Goldensohn, E S
1996-03-01
An EEG epileptiform spike focus recorded with scalp electrodes is clinically localized by visual estimation of the point of maximal voltage and the distribution of its surrounding voltages. We compared such estimated voltage maps, drawn by experienced electroencephalographers (EEGers), with a computerized spline interpolation technique employed in the commercially available software package FOCUS. Twenty-two spikes were recorded from 15 patients during long-term continuous EEG monitoring. Maps of voltage distribution from the 28 electrodes surrounding the points of maximum change in slope (the spike maximum) were constructed by the EEGer. The same points of maximum spike and voltage distributions at the 29 electrodes were mapped by computerized spline interpolation and a comparison between the two methods was made. The findings indicate that the computerized spline mapping techniques employed in FOCUS construct voltage maps with similar maxima and distributions as the maps created by experienced EEGers. The dynamics of spike activity, including correlations, are better visualized using the computerized technique than by manual interpretation alone. Its use as a technique for spike localization is accurate and adds information of potential clinical value.
Computerized Torque Control for Large dc Motors
NASA Technical Reports Server (NTRS)
Willett, Richard M.; Carroll, Michael J.; Geiger, Ronald V.
1987-01-01
Speed and torque ranges in generator mode extended. System of shunt resistors, electronic switches, and pulse-width modulation controls torque exerted by large, three-phase, electronically commutated dc motor. Particularly useful for motor operating in generator mode because it extends operating range to low torque and high speed.
ERIC Educational Resources Information Center
Tempel, Melissa Bollow
2012-01-01
Computerized testing, including the widely used MAP test, has infiltrated the public schools in Milwaukee and across the nation, bringing with it a frightening future for public education. High-stakes standardized tests can be scored almost immediately via the internet, and testing companies can now easily link districts to their online data…
Conative aptitudes in science learning
NASA Astrophysics Data System (ADS)
Jackson, Douglas Northrop, III
2000-09-01
The conative domain of aptitude constructs spans the domains of individual differences in motivation and volition. This research sampled a broad range of conative constructs, including achievement motivation, anxiety, goal orientations, and interest, among others. The purpose was threefold: (a) to explore relationships among conative constructs hypothesized to affect student commitment to learning and subsequent performance, (b) to determine whether or not individual differences in conative constructs were associated with the learning activities and time-on-task of students learning science, and (c) to ascertain whether or not the conative constructs and the time and activity variables were associated with performance differences in a paper-and-pencil science recall measure. This research consisted of three separate studies. Study I involved 60 U.S. college students. In Study II, 234 Canadian high school students participated. These two studies investigated the construct validity of a selection of conative constructs. A principal components analysis of the measures was undertaken and yielded seven components: Pursuit of Excellence, Evaluation Anxiety, Self-Reported Grades, Science Confidence, Science Interest vs. Science Ambivalence, Performance Orientation, and Verbal Ability. For Study III, 82 Canadian high school students completed the same conative questionnaires as were administered in Study II. A computerized environment patterned after an internet browser allowed students to learn about disease-causing microbes. The environment yielded aggregate measures of the time spent learning science, the time spent playing games, the number of games played, and the number of science-related learning activities engaged in by each student. Following administration of the computerized learning environment, students were administered a paper-and pencil science recall measure. Study III found support for the educational importance of the conative variables. Among the principal components, the strongest positive relationship was found between Science Interest vs. Science Ambivalence and performance on the recall measure. Scores on the conative variables were also correlated with both the time and activity variables from the computerized learning task. The implications of the findings are discussed with regard to the construct validation of conative constructs, the use of conative constructs for future educational research, and the design of computerized learning environments for both educational research and applied use.
1984-06-20
AD-A162 ±88 FEASIBILITY STUDY FOR A COMPUTERIZED SERIALS CONTROL 1/1 SYSTEM IN THE DEFENS (U) DEFENSE COMMUNICATIONS AGENCY WASHINGTON DC TECHNICAL...NATIONAL BUREAU OF STANDARDS- 1963-A 0FEASIBILITY STUDY FOR A COMPUTERIZED SERIALS CONTROL SYSTEM IN THE DEFENSE COMMUNICATIONS 0AGENCY TECHNICAL AND...ABSTRACT 21. ABSTRACT SECURITY CLASSIFICATION UNCLASSIFIED/UNLIMITED R1 SAME AS RPT. 0 DTIC USERS 0 UNCLASSIFIED 22&. NAME OF RESPONSIBLE INDIVIDUAL 22b
Hirschmann, Michael T.; Schmid, Rahel; Dhawan, Ranju; Skarvan, Jiri; Rasch, Helmut; Friederich, Niklaus F.; Emery, Roger
2011-01-01
With the cases described, we strive to introduce single photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) to shoulder surgeons, illustrate the possible clinical value it may offer as new diagnostic radiologic modality, and discuss its limitations. SPECT/CT may facilitate the establishment of diagnosis, process of decision making, and further treatment for complex shoulder pathologies. Some of these advantages were highlighted in cases that are frequently seen in most shoulder clinics. PMID:22058640
NASA Astrophysics Data System (ADS)
Yang, Wei; Zhang, Su; Li, Wenying; Chen, Yaqing; Lu, Hongtao; Chen, Wufan; Chen, Yazhu
2010-04-01
Various computerized features extracted from breast ultrasound images are useful in assessing the malignancy of breast tumors. However, the underlying relationship between the computerized features and tumor malignancy may not be linear in nature. We use the decision tree ensemble trained by the cost-sensitive boosting algorithm to approximate the target function for malignancy assessment and to reflect this relationship qualitatively. Partial dependence plots are employed to explore and visualize the effect of features on the output of the decision tree ensemble. In the experiments, 31 image features are extracted to quantify the sonographic characteristics of breast tumors. Patient age is used as an external feature because of its high clinical importance. The area under the receiver-operating characteristic curve of the tree ensembles can reach 0.95 with sensitivity of 0.95 (61/64) at the associated specificity 0.74 (77/104). The partial dependence plots of the four most important features are demonstrated to show the influence of the features on malignancy, and they are in accord with the empirical observations. The results can provide visual and qualitative references on the computerized image features for physicians, and can be useful for enhancing the interpretability of computer-aided diagnosis systems for breast ultrasound.
Computerized techniques pave the way for drug-drug interaction prediction and interpretation
Safdari, Reza; Ferdousi, Reza; Aziziheris, Kamal; Niakan-Kalhori, Sharareh R.; Omidi, Yadollah
2016-01-01
Introduction: Health care industry also patients penalized by medical errors that are inevitable but highly preventable. Vast majority of medical errors are related to adverse drug reactions, while drug-drug interactions (DDIs) are the main cause of adverse drug reactions (ADRs). DDIs and ADRs have mainly been reported by haphazard case studies. Experimental in vivo and in vitro researches also reveals DDI pairs. Laboratory and experimental researches are valuable but also expensive and in some cases researchers may suffer from limitations. Methods: In the current investigation, the latest published works were studied to analyze the trend and pattern of the DDI modelling and the impacts of machine learning methods. Applications of computerized techniques were also investigated for the prediction and interpretation of DDIs. Results: Computerized data-mining in pharmaceutical sciences and related databases provide new key transformative paradigms that can revolutionize the treatment of diseases and hence medical care. Given that various aspects of drug discovery and pharmacotherapy are closely related to the clinical and molecular/biological information, the scientifically sound databases (e.g., DDIs, ADRs) can be of importance for the success of pharmacotherapy modalities. Conclusion: A better understanding of DDIs not only provides a robust means for designing more effective medicines but also grantees patient safety. PMID:27525223
[The importance of neurological examinations in the age of the technological revolution].
Berbel-García, A; González-Spínola, J; Martínez-Salio, A; Porta-Etessam, J; Pérez-Martínez, D A; de Toledo, M; Sáiz-Díaz, R A
Neurologic practice and care have been modified in many important ways during the past ten years, to adapt to the explosion of new information and new technology. Students, residents and practicing physicians have been continuing programs to a model that focuses almost exclusively on the applications to neurologic disorders of the new knowledge obtained from biomedical research. On the other hand high demand for outpatient neurologic care prevents adequate patient's evaluation. Case 1: 65 years old female. Occipital headache diagnosed of tensional origin (normal computerized tomography). Two months later is re-evaluated due to intractable pain and hypoglossal lesion. An amplified computerized tomography revealed a occipital condyle metastasis. Case 2: 21 years old female. Clinical suspicion of demyelinating disease due to repeated facial paresis and sensitive disorder. General exploration and computerized tomography revealed temporo-mandibular joint. Case 3: 60 years old female. Valuation of anticoagulant therapy due to repeated transient ischemic attacks. She suffered from peripheral facial palsy related to auditory cholesteatoma. Neurologic education is nowadays orientated to new technologies. On the other hand, excessive demand prevents adequate valuation and a minute exploration is substituted by complementary evaluations. These situations generate diagnostic mistakes or iatrogenic. It would be important a consideration of the neurologic education profiles and fulfillment of consultations time recommendations for outpatients care.
I've Fallen and I Can't Get up: Can High-Ability Students Recover from Early Mistakes in CAT?
ERIC Educational Resources Information Center
Rulison, Kelly L.; Loken, Eric
2009-01-01
A difficult result to interpret in Computerized Adaptive Tests (CATs) occurs when an ability estimate initially drops and then ascends continuously until the test ends, suggesting that the true ability may be higher than implied by the final estimate. This study explains why this asymmetry occurs and shows that early mistakes by high-ability…
ERIC Educational Resources Information Center
Allan, Blaine W., Comp.
The procedures, forms, and philosophy of the computerized modular scheduling program developed at Virgin Valley High School are outlined. The modular concept is eveloped as a new approach to course structure with explanations, examples, and worksheets included. Examples of courses of study, input information for the data processing center, output…
Enhancing Vowel Discrimination Using Constructed Spelling
ERIC Educational Resources Information Center
Stewart, Katherine; Hayashi, Yusuke; Saunders, Kathryn
2010-01-01
In a computerized task, an adult with intellectual disabilities learned to construct consonant-vowel-consonant words in the presence of corresponding spoken words. During the initial assessment, the participant demonstrated high accuracy on one word group (containing the vowel-consonant units "it" and "un") but low accuracy on the other group…
Involvement of Working Memory in College Students' Sequential Pattern Learning and Performance
ERIC Educational Resources Information Center
Kundey, Shannon M. A.; De Los Reyes, Andres; Rowan, James D.; Lee, Bern; Delise, Justin; Molina, Sabrina; Cogdill, Lindsay
2013-01-01
When learning highly organized sequential patterns of information, humans and nonhuman animals learn rules regarding the hierarchical structures of these sequences. In three experiments, we explored the role of working memory in college students' sequential pattern learning and performance in a computerized task involving a sequential…
Case Studies in Library Computer Systems.
ERIC Educational Resources Information Center
Palmer, Richard Phillips
Twenty descriptive case studies of computer applications in a variety of libraries are presented in this book. Computerized circulation, serial and acquisition systems in public, high school, college, university and business libraries are included. Each of the studies discusses: 1) the environment in which the system operates, 2) the objectives of…
Computerized Educational Delivery Strategies in Nine North American Colleges.
ERIC Educational Resources Information Center
Bowles, John C.
1988-01-01
Results of survey of high technology educational delivery systems in nine two-year colleges (five in the United States and four in Canada) emphasize the use of computers to provide alternatives to traditional classroom teaching. Topics discussed include open education, self-paced (fleximode) learning, artificial intelligence, software, and…
Teacher Training for High Technology. Final Report.
ERIC Educational Resources Information Center
Goettmann, Thomas L.
The objective of this project was to develop computer literacy and a working knowledge of microprocessor applications and digital circuits for teachers in selected vocational subject areas. Twenty-four vocational trade and industry teachers completed 16 hours of training in microprocessor skills for computerized instruction and curriculum update.…
Computerization of School Administration: Impact on the Principal's Role--A Case Study.
ERIC Educational Resources Information Center
Telem, Moshe
2001-01-01
Describes a study at an Israeli high school that investigated changes in the principal's role as the result of the introduction of a school management information system (SMIS). Discusses information handling and flow, interrelations with teachers, accountability, instruction evaluation, supervision, feedback, frequency of meetings, and shared…
NASA Technical Reports Server (NTRS)
Merwarth, P., D.
1983-01-01
The Common Software Module Repository (CSMR) is computerized library system with high product and service visibility to potential users. Online capabilities of system allow both librarian and user to interact with library. Librarian is responsible for maintaining information in CSMR library. User searches library to locate software modules that meet his or her current needs.
Computer Aided Training of Cognitive Processing Strategies with Developmentally Handicapped Adults.
ERIC Educational Resources Information Center
Ryba, Kenneth A.; And Others
1985-01-01
Correlational results involving 60 developmentally handicaped adults indicated that a computerized cross-modal memory game had a highly significant relationship with most cognitive and motor coordination measures. Computer aided training was not effective in improving overall cognitive functioning. There was no evidence of cognitive skills being…
Computerized History Games: Narrative Options
ERIC Educational Resources Information Center
Kee, Kevin
2011-01-01
How may historians best express history through computer games? This article suggests that the answer lies in correctly correlating historians' goals for teaching with the capabilities of different kinds of computer games. During the development of a game prototype for high school students, the author followed best practices as expressed in the…
ERIC Educational Resources Information Center
Butler, Loren L.
2004-01-01
When it comes to technological wizardry in the classroom, interactive whiteboards stand on the cutting edge of the future. Students seem innately able to manipulate any type of computerized equipment, and, more important, they are highly motivated to engage in "techno-discovery." It is the duty of every educator to facilitate further discovery and…
Solving Infeasibility Problems in Computerized Test Assembly.
ERIC Educational Resources Information Center
Timminga, Ellen
1998-01-01
Discusses problems of diagnosing and repairing infeasible linear-programming models in computerized test assembly. Demonstrates that it is possible to localize the causes of infeasibility, although this is not always easy. (SLD)
The School Building Principal and Inventory Control: A Case for Computerization.
ERIC Educational Resources Information Center
Stronge, James
1987-01-01
General and special purpose database programs are appropriate for inventory control at the school building level. A fixed asset equipment inventory example illustrates the feasibility of computerized inventory control. (MLF)
ERIC Educational Resources Information Center
Loucky, John Paul
2003-01-01
Compares various computerized bilingual dictionaries for their relative effectiveness in helping Japanese college students at several language proficiency levels to access new English target vocabulary. (Author/VWL)
Computerized Adaptive Testing: Overview and Introduction.
ERIC Educational Resources Information Center
Meijer, Rob R.; Nering, Michael L.
1999-01-01
Provides an overview of computerized adaptive testing (CAT) and introduces contributions to this special issue. CAT elements discussed include item selection, estimation of the latent trait, item exposure, measurement precision, and item-bank development. (SLD)
Khammarnia, Mohammad; Sharifian, Roxana; Zand, Farid; Keshtkaran, Ali; Barati, Omid
2016-09-01
This study aimed to identify the functional requirements of computerized provider order entry software and design this software in Iran. This study was conducted using review documentation, interview, and focus group discussions in Shiraz University of Medical Sciences, as the medical pole in Iran, in 2013-2015. The study sample consisted of physicians (n = 12) and nurses (n = 2) in the largest hospital in the southern part of Iran and information technology experts (n = 5) in Shiraz University of Medical Sciences. Functional requirements of the computerized provider order entry system were examined in three phases. Finally, the functional requirements were distributed in four levels, and accordingly, the computerized provider order entry software was designed. The software had seven main dimensions: (1) data entry, (2) drug interaction management system, (3) warning system, (4) treatment services, (5) ability to write in software, (6) reporting from all sections of the software, and (7) technical capabilities of the software. The nurses and physicians emphasized quick access to the computerized provider order entry software, order prescription section, and applicability of the software. The software had some items that had not been mentioned in other studies. Ultimately, the software was designed by a company specializing in hospital information systems in Iran. This study was the first specific investigation of computerized provider order entry software design in Iran. Based on the results, it is suggested that this software be implemented in hospitals.
Computerization of a telescope at secondary education
NASA Astrophysics Data System (ADS)
García Santiago, A.; Martos Jumillas, J.
2017-03-01
The work we are presenting in this paper is the computerization of a refractor telescope on an EQ3 type equatorial mount through Arduino. The control of the mount is done via three different interfaces: Stellarium, an Android interface for mobile phones and a second interface for PC made with Processing. The aforementioned work was done by the authors with a double purpose: presenting the interest in astronomy in the Mathematics department, and the development of applications within the subject of Technology in 4th ESO. So, it is a collaborative project between both departments. Except for the telescope and the mount, all the resources we have used can be found in any high school: free software (Guadalinex v9), App Inventor and Processing.The project was carried out under the principle of reducing all possible costs given the economic possibilities of the institution.
The mobile hospital technology industry: focus on the computerized tomography scanner.
Hartley, D; Moscovice, I
1996-01-01
This study of firms offering mobile hospital technology to rural hospitals in eight northwestern states found that several permanently parked computerized tomography (CT) units were found where mobile routes had atrophied due to the purchase of fixed units by former mobile CT hospital clients. Based on a criterion of 140 scans per month per unit as a threshold of profitable production, units owned by larger firms (those that operate five or more units) were more likely to be profitable than units owned by smaller firms (71% versus 20%, P = 0.03). A substantial number of rural hospitals lose money on mobile CT due to low Medicare reimbursement. In some areas, mobile hospital technology is a highly competitive industry. Evidence was found that several firms compete in some geographic areas and that some firms have lost hospital clients to competing vendors.
Nakano, Masahiko; Yoshikawa, Takeshi; Hirata, So; Seino, Junji; Nakai, Hiromi
2017-11-05
We have implemented a linear-scaling divide-and-conquer (DC)-based higher-order coupled-cluster (CC) and Møller-Plesset perturbation theories (MPPT) as well as their combinations automatically by means of the tensor contraction engine, which is a computerized symbolic algebra system. The DC-based energy expressions of the standard CC and MPPT methods and the CC methods augmented with a perturbation correction were proposed for up to high excitation orders [e.g., CCSDTQ, MP4, and CCSD(2) TQ ]. The numerical assessment for hydrogen halide chains, polyene chains, and first coordination sphere (C1) model of photoactive yellow protein has revealed that the DC-based correlation methods provide reliable correlation energies with significantly less computational cost than that of the conventional implementations. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Glick, Stephen J.; Didier, Clay
2013-01-01
A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5–3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used. PMID:24187383
Anthropometric and computerized tomographic measurements of lower extremity lean body mass.
Buckley, D C; Kudsk, K A; Rose, B S; Fatzinger, P; Koetting, C A; Schlatter, M
1987-02-01
The loss of lean muscle mass is one of the hallmarks of protein-calorie malnutrition. Anthropometry is a standardized technique used to assess the response of muscle mass to nutrition therapy by quantifying the muscle and fat compartments. That technique does not accurately reflect actual limb composition, whereas computerized tomography does. Twenty lower extremities on randomly chosen men and women patients were evaluated by anthropometry and computerized tomography. Total area, muscle plus bone area, total volume, and muscle plus bone volume were correlated, using Heymsfield's equation and computerized tomography-generated areas. Anthropometrics overestimated total and muscle plus bone cross-sectional areas at almost every level. Anthropometry overestimated total area and total volume by 5% to 10% but overestimated muscle plus bone area and muscle plus bone volume by as much as 40%. Anthropometry, while easily performed and useful in large population groups for epidemiological studies, offers a poor assessment of lower extremity composition. On the other hand, computerized tomography is also easily performed and, while impractical for large population groups, does offer an accurate assessment of the lower extremity tissue compartments and is an instrument that might be used in research on lean muscle mass.
Economics of infection control surveillance technology: cost-effective or just cost?
Furuno, Jon P; Schweizer, Marin L; McGregor, Jessina C; Perencevich, Eli N
2008-04-01
Previous studies have suggested that informatics tools, such as automated alert and decision support systems, may increase the efficiency and quality of infection control surveillance. However, little is known about the cost-effectiveness of these tools. We focus on 2 types of economic analyses that have utility in assessing infection control interventions (cost-effectiveness analysis and business-case analysis) and review the available literature on the economics of computerized infection control surveillance systems. Previous studies on the effectiveness of computerized infection control surveillance have been limited to assessments of whether these tools increase the sensitivity and specificity of surveillance over traditional methods. Furthermore, we identified only 2 studies that assessed the costs associated with computerized infection control surveillance. Thus, it remains unknown whether computerized infection control surveillance systems are cost-effective and whether use of these systems improves patient outcomes. The existing data are insufficient to allow for a summary conclusion on the cost-effectiveness of infection control surveillance technology. All future studies of computerized infection control surveillance systems should aim to collect outcomes and economic data to inform decision making and assist hospitals with completing business-cases analyses.
Troise Rioda, W.; Nervetti, A.
2001-01-01
The well known complexity to collect the clinical data of patients and in particular in the area of rheumatology push us to develop a computerized clinical chart in order to facilitate the classification, evaluation and monitoring of these patients. The proposed computerized clinical chart is easy to use but at the same time is a very potent tool that allow the clinicians to organize the classic rheumatological pathologies as well as the more complexes or even rare. The proposed clinical chart is based on a relational database (FileMaker Pro 5.0v1) available for both the actual operative systems implemented on personal computers (Windows and Macintosh); this allow the full compatibility among the two systems, the possibility of exchanging data without any loss of information. The computerized clinical chart is structured on modules for specific pathologies and for homogeneous groups of illnesses. Basically the modules are defined correlated files of data for a specific pathology but that can be used also as a common pool for different pathologies. Our experience, based on ten years of use, indicates in the computerized rheumatological clinical chart an indispensable tool for rheumatologists with a real friendly use.
Gomar, Jesús J; Valls, Elia; Radua, Joaquim; Mareca, Celia; Tristany, Josep; del Olmo, Francisco; Rebolleda-Gil, Carlos; Jañez-Álvarez, María; de Álvaro, Francisco J; Ovejero, María R; Llorente, Ana; Teixidó, Cristina; Donaire, Ana M; García-Laredo, Eduardo; Lazcanoiturburu, Andrea; Granell, Luis; Mozo, Cristina de Pablo; Pérez-Hernández, Mónica; Moreno-Alcázar, Ana; Pomarol-Clotet, Edith; McKenna, Peter J
2015-11-01
The effectiveness of cognitive remediation therapy (CRT) for the neuropsychological deficits seen in schizophrenia is supported by meta-analysis. However, a recent methodologically rigorous trial had negative findings. In this study, 130 chronic schizophrenic patients were randomly assigned to computerized CRT, an active computerized control condition (CC) or treatment as usual (TAU). Primary outcome measures were 2 ecologically valid batteries of executive function and memory, rated under blind conditions; other executive and memory tests and a measure of overall cognitive function were also employed. Carer ratings of executive and memory failures in daily life were obtained before and after treatment. Computerized CRT was found to produce improvement on the training tasks, but this did not transfer to gains on the primary outcome measures and most other neuropsychological tests in comparison to either CC or TAU conditions. Nor did the intervention result in benefits on carer ratings of daily life cognitive failures. According to this study, computerized CRT is not effective in schizophrenia. The use of both active and passive CCs suggests that nature of the control group is not an important factor influencing results. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.
[Modernized study on eye's signs of blood-stasis syndrome].
Wu, Rui; Xie, Jian-xiang; Zhao, Feng-da
2011-03-01
To make out a computerized formula to diagnose eye's signs of blood-stasis syndrome (BSS), and to improve the previous diagnostic methods by naked eyes. The formula was created by detecting and analyzing the changes of eye's signs in 544 patients (261 of non-BSS and 283 of BSS) quantitatively, adopting computer's color scale principle. And the sensitivity, specificity and accuracy of the formula were verified in 382 patients (97 non-BSS and 285 of BSS). The computerized integral was compared with the naked eye integral, and the normal reference value was calculated with percentile. Various observatory indices of eye's sign were positively correlated with BSS. The specificity of the computerized method was 83.5%, and the diagnostic sensitivity was 89.8%, the accuracy 88.2%, and the correct index 0.733. Comparisons between the computerized integral method and the naked eye integral method showed significant difference in patients of non-BSS or of BSS in various degrees (including mild, moderate and severe) (P < 0.01). The reference value of the naked eye method was below 15. The computerized formula of eye's signs has higher specificity and sensitivity in the diagnosis of BSS, while the naked eye integral method is proved to be useful.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uzochukwu, G.A.
1997-12-31
Nuclear and commercial non-nuclear technologies that have the potential of meeting the environmental restoration, decontamination and decommissioning, and high-level waste management objectives are being assessed and evaluated. A detailed comparison of innovative technologies available will be performed to determine the safest and most economical technology for meeting these objectives. Information derived from this effort will be matched with the multi-objectives of the environmental restoration, decontamination and decommissioning, and high-level waste management effort to ensure that the best, most economical, and the safest technologies are used in decision making at USDOE-SRS. Technology-related variables will be developed and the resulting data formattedmore » and computerized for multimedia systems. The multimedia system will be made available to technology developers and evaluators to ensure that the best, most economical, and the safest technologies are used in decision making at USDOE-SRS. Technology-related variables will be developed and the resulting data formatted and computerized for multimedia systems. The multimedia system will be made available to technology developers and evaluators to ensure that the safest and most economical technologies are developed for use at SRS and other DOE sites.« less
A computerized resolution of scheduling conflicts.
Bolinger, R E; McFarlane, M J
1989-01-01
Residency training programs in Internal Medicine require resident attendance in a continuity clinic. This inevitably engenders conflicts between scheduling in the ambulatory clinic and the required teaching activities of the in-patient services. Some of the conflicts can be resolved by allowing the in-patient service directors to indicate preferred plans for their residents to attend in the continuity clinic. With this plan, scheduling becomes quite complicated. A computer program is presented with coordinates these service requests with ambulatory clinic scheduling. As a result, a given resident may have his/her clinic day changed on different rotations. The program automatically arbitrates conflicts and publishes the attendance dates for the entire academic year. This information is supplied to the appointment desk so that patients can be scheduled accordingly. This system has resulted in a 74% continuity rate and improved satisfaction by both residents and staff.
Context-sensitive patch histograms for detecting rare events in histopathological data
NASA Astrophysics Data System (ADS)
Diaz, Kristians; Baust, Maximilian; Navab, Nassir
2017-03-01
Assessment of histopathological data is not only difficult due to its varying appearance, e.g. caused by staining artifacts, but also due to its sheer size: Common whole slice images feature a resolution of 6000x4000 pixels. Therefore, finding rare events in such data sets is a challenging and tedious task and developing sophisticated computerized tools is not easy, especially when no or little training data is available. In this work, we propose learning-free yet effective approach based on context sensitive patch-histograms in order to find extramedullary hematopoiesis events in Hematoxylin-Eosin-stained images. When combined with a simple nucleus detector, one can achieve performance levels in terms of sensitivity 0.7146, specificity 0.8476 and accuracy 0.8353 which are very well comparable to a recently published approach based on random forests.
Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian
2015-01-01
The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone. PMID:26266764
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobray, D.
Louisiana is a leading producer of oil and gas despite its small size in comparison with Texas, Alaska, and California. The author describes the basic features of Louisiana's unique property system and the forms of mineral ownership under that system, including divided ownership and pooled interests. She examines the state's pro-development doctrine of liberative prescription and its effect on mineral rights, and discusses the policy choices which permeate the state's approach. Louisiana mineral law is based upon notions inherent in the Civil Law that dismembered interests in land cannot be conveyed in perpetuity nor transferred or reserved as future interests,more » which allows mineral rights to be terminated if they are unused. Louisiana incorporates a computerized approach to dispute resolution, thanks to a rich legislative and jurisprudential background.« less
Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian
2015-08-12
The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone.
NASA Technical Reports Server (NTRS)
1977-01-01
Components of a videotape storage and retrieval system originally developed for NASA have been adapted as a tool for law enforcement agencies. Ampex Corp., Redwood City, Cal., built a unique system for NASA-Marshall. The first application of professional broadcast technology to computerized record-keeping, it incorporates new equipment for transporting tapes within the system. After completing the NASA system, Ampex continued development, primarily to improve image resolution. The resulting advanced system, known as the Ampex Videofile, offers advantages over microfilm for filing, storing, retrieving, and distributing large volumes of information. The system's computer stores information in digital code rather than in pictorial form. While microfilm allows visual storage of whole documents, it requires a step before usage--developing the film. With Videofile, the actual document is recorded, complete with photos and graphic material, and a picture of the document is available instantly.
Stabilometer Computerized Analog Recording System for Studying Gross Motor Skill Learning
ERIC Educational Resources Information Center
Chasey, William C., Jr.; And Others
1976-01-01
The stabilometer computerized analog recording system (SCARS) provides for storing analog and digital information on a single channel audio tape recorder at lower cost and greater versatility than other systems. (MB)
Computerized Working-Memory Training as a Candidate Adjunctive Treatment for Addiction
Bickel, Warren K.; Moody, Lara; Quisenberry, Amanda
2014-01-01
Alcohol and other drug dependencies are, in part, characterized by deficits in executive functioning, including working memory. Working-memory training is a candidate computerized adjunctive intervention for the treatment of alcoholism and other drug dependencies. This article reviews emerging evidence for computerized working memory training as an efficacious adjunctive treatment for drug dependence and highlights future challenges and opportunities in the field of working-memory training, including duration of training needed, persistence of improvements and utility of booster sessions, and selection of patients based on degree of deficits. PMID:26259006
NASA Astrophysics Data System (ADS)
Collmann, Jeff R.
2003-05-01
This paper justifies and explains current efforts in the Military Health System (MHS) to enhance information assurance in light of the sociological debate between "Normal Accident" (NAT) and "High Reliability" (HRT) theorists. NAT argues that complex systems such as enterprise health information systems display multiple, interdependent interactions among diverse parts that potentially manifest unfamiliar, unplanned, or unexpected sequences that operators may not perceive or immediately understand, especially during emergencies. If the system functions rapidly with few breaks in time, space or process development, the effects of single failures ramify before operators understand or gain control of the incident thus producing catastrophic accidents. HRT counters that organizations with strong leadership support, continuous training, redundant safety features and "cultures of high reliability" contain the effects of component failures even in complex, tightly coupled systems. Building highly integrated, enterprise-wide computerized health information management systems risks creating the conditions for catastrophic breaches of data security as argued by NAT. The data security regulations of the Health Insurance Portability and Accountability Act of 1996 (HIPAA) implicitly depend on the premises of High Reliability Theorists. Limitations in HRT thus have implications for both safe program design and compliance efforts. MHS and other health care organizations should consider both NAT and HRT when designing and deploying enterprise-wide computerized health information systems.
Computer versus paper system for recognition and management of sepsis in surgical intensive care.
Croft, Chasen A; Moore, Frederick A; Efron, Philip A; Marker, Peggy S; Gabrielli, Andrea; Westhoff, Lynn S; Lottenberg, Lawrence; Jordan, Janeen; Klink, Victoria; Sailors, R Matthew; McKinley, Bruce A
2014-02-01
A system to provide surveillance, diagnosis, and protocolized management of surgical intensive care unit (SICU) sepsis was undertaken as a performance improvement project. A system for sepsis management was implemented for SICU patients using paper followed by a computerized system. The hypothesis was that the computerized system would be associated with improved process and outcomes. A system was designed to provide early recognition and guide patient-specific management of sepsis including (1) modified early warning signs-sepsis recognition score (MEWS-SRS; summative point score of ranges of vital signs, mental status, white blood cell count; after every 4 hours) by bedside nurse; (2) suspected site assessment (vascular access, lung, abdomen, urinary tract, soft tissue, other) at bedside by physician or extender; (3) sepsis management protocol (replicable, point-of-care decisions) at bedside by nurse, physician, and extender. The system was implemented first using paper and then a computerized system. Sepsis severity was defined using standard criteria. In January to May 2012, a paper system was used to manage 77 consecutive sepsis encounters (3.9 ± 0.5 cases per week) in 65 patients (77% male; age, 53 ± 2 years). In June to December 2012, a computerized system was used to manage 132 consecutive sepsis encounters (4.4 ± 0.4 cases per week) in 119 patients (63% male; age, 58 ± 2 years). MEWS-SRS elicited 683 site assessments, and 201 had sepsis diagnosis and protocol management. The predominant site of infection was abdomen (paper, 58%; computer, 53%). Recognition of early sepsis tended to occur more using the computerized system (paper, 23%; computer, 35%). Hospital mortality rate for surgical ICU sepsis (paper, 20%; computer, 14%) was less with the computerized system. A computerized sepsis management system improves care process and outcome. Early sepsis is recognized and managed with greater frequency compared with severe sepsis or septic shock. The system has a beneficial effect as a clinical standard of care for SICU patients. Therapeutic study, level III.
Computerized tomography using video recorded fluoroscopic images
NASA Technical Reports Server (NTRS)
Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.
1975-01-01
A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.
The Deference Due the Oracle: Computerized Text Analysis in a Basic Writing Class.
ERIC Educational Resources Information Center
Otte, George
1989-01-01
Describes how a computerized text analysis program can help students discover error patterns in their writing, and notes how students' responses to analyses can reduce errors and improve their writing. (MM)
Evaluation of the Salt Lake City Computerized Rider Information System
DOT National Transportation Integrated Search
1985-11-01
The Utah Transit Authority (UTA) Computerized Rider Information System (CRIS) project involved the installation of an automated telephone service to quickly provide bus stop-specific schedule and service information to residents throughout the Author...
An overview of Virginia's computerized crash records systems.
DOT National Transportation Integrated Search
1995-01-01
This report identifies the various components of Virginia's computerized crash records systems and explains how these components process crash data. Emphasis has been placed on recording information that was previously not documented. Most of the sta...
Technology in the Assessment of Learning Disability.
ERIC Educational Resources Information Center
Bigler, Erin D.; Lajiness-O'Neill, Renee; Howes, Nancy-Louise
1998-01-01
Reviews recent neuroradiologic and brain imaging techniques in the assessment of learning disability. Technologies reviewed include computerized tomography; magnetic resonance imaging; electrophysiological and metabolic imaging; computerized electroencepholographic studies of evoked potentials, event-related potentials, spectral analysis, and…
Computerization of material test data reporting system : interim report.
DOT National Transportation Integrated Search
1973-09-01
This study was initiated to provide an integrated system of reporting, storing, and retrieving of construction and material test data using computerized (storage-retrieval) and quality control techniques. The findings reported in this interim report ...
Overton, Edgar Turner; Kauwe, John S K; Paul, Robert; Tashima, Karen; Tate, David F; Patel, Pragna; Carpenter, Charles C J; Patty, David; Brooks, John T; Clifford, David B
2011-11-01
HIV-associated neurocognitive disorders remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (P < 0.01). These data confirm previous correlation data with the computerized battery. Using the five significant parameters from the regression model in a Receiver Operating Characteristic curve, 90% of persons were accurately classified as being cognitively impaired or not. The test battery requires additional evaluation, specifically for identifying persons with mild impairment, a state upon which interventions may be effective.
Knutsson, A
1986-01-01
For 10 years computerization in industry has advanced at a rapid pace. A problem which has not received attention is that of people with reading and writing difficulties who experience severe problems when they have to communicate with a computer monitor screen. These individuals are often embarrassed by their difficulties and conceal them from their fellow workers. A number of case studies are described which show the form the problems can take. In one case, an employee was compelled to move from department to department as each was computerized in turn. Computers transform a large number of manual tasks in industry into jobs which call for reading and writing skills. Better education at elementary school and at the workplace in connection with computerization are the most important means of overcoming this problem. Moreover, computer programs could be written in a more human way.
Computerized NCLEX-RN and NCLEX-PN preparation programs. Comparative review, 1997.
Riner, M E; Mueller, C; Ihrke, B; Smolen, R A; Wilson, M; Richardson, V; Stone, C; Zwirn, E E
1997-01-01
The computerized test taking market continues to expand to meet the needs of nursing students studying to prepare for the NCLEX-RN and the NCLEX-PN. In addition, currently registered nurses may choose to use these software programs to review clinical knowledge in areas in which they are not currently practicing. This article reviewed software designed for personal use, review books with complete disks, on-site institutional testing and consultation, and school of nursing LANs. The costs of software for personal use is priced reasonably and provides flexibility for students to use as their schedule permits. The cost of institutional licenses is moderate and most programs provide multiple on-site use rights. The marketplace has responded to the computerized NCLEX testing now in place nationally. As new formats are developed and new uses identified, nursing faculty and students can expect to see an expanded use of computerized testing.
Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients
Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.
2008-01-01
Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982
Breitborde, Nicholas J K; Woolverton, Cindy; Dawson, Spencer C; Bismark, Andrew; Bell, Emily K; Bathgate, Christina J; Norman, Kaila
2017-06-01
Meta-cognitive skills training (MST) is a frequent component of cognitive remediation programmes for individuals with psychosis. However, no study has investigated whether incorporating such activities produces increased clinical benefits compared with computerized cognitive remediation alone. Individuals with first-episode psychosis who completed computerized cognitive remediation with concurrent meta-cognitive skills training (CCR + MST) were compared with a historical control group who received computerized cognitive remediation alone (CCR) and did not differ from the CCR + MST group with regard to pre-intervention cognition, diagnosis, age, duration of psychotic illness or sex. Participants completed assessments of cognition and real-world functioning before and after 6 months of treatment. Individual receiving CCR + MST experience greater gains in cognition and real-world functioning than individuals who received CCR. MST may be an important component within cognitive remediation programmes for first-episode psychosis. © 2015 Wiley Publishing Asia Pty Ltd.
Gaffney, Hannah; Mansell, Warren; Edwards, Rachel; Wright, Jason
2014-11-01
Computerized self-help that has an interactive, conversational format holds several advantages, such as flexibility across presenting problems and ease of use. We designed a new program called MYLO that utilizes the principles of METHOD of Levels (MOL) therapy--based upon Perceptual Control Theory (PCT). We tested the efficacy of MYLO, tested whether the psychological change mechanisms described by PCT mediated its efficacy, and evaluated effects of client expectancy. Forty-eight student participants were randomly assigned to MYLO or a comparison program ELIZA. Participants discussed a problem they were currently experiencing with their assigned program and completed measures of distress, resolution and expectancy preintervention, postintervention and at 2-week follow-up. MYLO and ELIZA were associated with reductions in distress, depression, anxiety and stress. MYLO was considered more helpful and led to greater problem resolution. The psychological change processes predicted higher ratings of MYLO's helpfulness and reductions in distress. Positive expectancies towards computer-based problem solving correlated with MYLO's perceived helpfulness and greater problem resolution, and this was partly mediated by the psychological change processes identified. The findings provide provisional support for the acceptability of the MYLO program in a non-clinical sample although its efficacy as an innovative computer-based aid to problem solving remains unclear. Nevertheless, the findings provide tentative early support for the mechanisms of psychological change identified within PCT and highlight the importance of client expectations on predicting engagement in computer-based self-help.
Modeling Pacing Behavior and Test Speededness Using Latent Growth Curve Models
ERIC Educational Resources Information Center
Kahraman, Nilufer; Cuddy, Monica M.; Clauser, Brian E.
2013-01-01
This research explores the usefulness of latent growth curve modeling in the study of pacing behavior and test speededness. Examinee response times from a high-stakes, computerized examination, collected before and after the examination was subjected to a timing change, were analyzed using a series of latent growth curve models to detect…
Do Contributors to Intellect Explain the Moral Judgment Abilities of Gifted Youth?
ERIC Educational Resources Information Center
Derryberry, W. Pitt; Barger, Brian
2008-01-01
To assess reaction time and attributional complexity as factors contributing to the relatively high moral judgment of gifted youth, a sample of 30 gifted youth and 30 college students responded to a computerized measure of moral judgment development, which also indexed reaction time. Additionally, participants completed a measurement of…
ERIC Educational Resources Information Center
Dori, Yehudit Judy; Kaberman, Zvia
2012-01-01
Much knowledge in chemistry exists at a molecular level, inaccessible to direct perception. Chemistry instruction should therefore include multiple visual representations, such as molecular models and symbols. This study describes the implementation and assessment of a learning unit designed for 12th grade chemistry honors students. The organic…
ERIC Educational Resources Information Center
Laflamme, Claude; Baby, Antoine
1993-01-01
Presents a model of youth transition from education to work that takes into account the disrupting effects of global economic crisis and massive computerization. Suggests that investment in new technologies reduces employment and polarizes remaining jobs to unskilled and highly skilled categories. Discusses psychosocial integration strategies…
Project BABS: Bilingual Academic and Business Skills 1983-1984. OEA Evaluation Report.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn. Office of Educational Assessment.
Project BABS, in its final year of funding, provided career exploration and advisement, after-school summer job internships with business enterprises, and a computerized reading program to approximately 690 students of limited English proficiency of Asian, Greek, Russian, and Hispanic descent in four New York City high schools. Project staff,…
Outlier Detection in High-Stakes Certification Testing. Research Report.
ERIC Educational Resources Information Center
Meijer, Rob R.
Recent developments of person-fit analysis in computerized adaptive testing (CAT) are discussed. Methods from statistical process control are presented that have been proposed to classify an item score pattern as fitting or misfitting the underlying item response theory (IRT) model in a CAT. Most person-fit research in CAT is restricted to…
Outlier Detection in High-Stakes Certification Testing.
ERIC Educational Resources Information Center
Meijer, Rob R.
2002-01-01
Used empirical data from a certification test to study methods from statistical process control that have been proposed to classify an item score pattern as fitting or misfitting the underlying item response theory model in computerized adaptive testing. Results for 1,392 examinees show that different types of misfit can be distinguished. (SLD)
AMTC: Assessing Motivation To Communicate in the Ninth Grade Speech Class.
ERIC Educational Resources Information Center
Fenton, Ray
A study examined the results of the use of the "Assessing Motivation To Communicate" (AMTC) computerized program with high school students in Anchorage, Alaska, during the 1995-96 school year. The AMTC consists of two self-assessment instruments: the Personal Report of Communication (PRCA-24) and the Willingness to Communicate (WTC).…
ERIC Educational Resources Information Center
Greifeneder, Rainer; Zelt, Sarah; Seele, Tim; Bottenberg, Konstantin; Alt, Alexander
2012-01-01
Background: Handwriting legibility systematically biases evaluations in that highly legible handwriting results in more positive evaluations than less legible handwriting. Because performance assessments in educational contexts are not only based on computerized or multiple choice tests but often include the evaluation of handwritten work samples,…
Hatipoglu, Nuh; Bilgin, Gokhan
2017-10-01
In many computerized methods for cell detection, segmentation, and classification in digital histopathology that have recently emerged, the task of cell segmentation remains a chief problem for image processing in designing computer-aided diagnosis (CAD) systems. In research and diagnostic studies on cancer, pathologists can use CAD systems as second readers to analyze high-resolution histopathological images. Since cell detection and segmentation are critical for cancer grade assessments, cellular and extracellular structures should primarily be extracted from histopathological images. In response, we sought to identify a useful cell segmentation approach with histopathological images that uses not only prominent deep learning algorithms (i.e., convolutional neural networks, stacked autoencoders, and deep belief networks), but also spatial relationships, information of which is critical for achieving better cell segmentation results. To that end, we collected cellular and extracellular samples from histopathological images by windowing in small patches with various sizes. In experiments, the segmentation accuracies of the methods used improved as the window sizes increased due to the addition of local spatial and contextual information. Once we compared the effects of training sample size and influence of window size, results revealed that the deep learning algorithms, especially convolutional neural networks and partly stacked autoencoders, performed better than conventional methods in cell segmentation.
NASA Astrophysics Data System (ADS)
Kazantsev, Daniil; Pickalov, Valery; Nagella, Srikanth; Pasca, Edoardo; Withers, Philip J.
2018-01-01
In the field of computerized tomographic imaging, many novel reconstruction techniques are routinely tested using simplistic numerical phantoms, e.g. the well-known Shepp-Logan phantom. These phantoms cannot sufficiently cover the broad spectrum of applications in CT imaging where, for instance, smooth or piecewise-smooth 3D objects are common. TomoPhantom provides quick access to an external library of modular analytical 2D/3D phantoms with temporal extensions. In TomoPhantom, quite complex phantoms can be built using additive combinations of geometrical objects, such as, Gaussians, parabolas, cones, ellipses, rectangles and volumetric extensions of them. Newly designed phantoms are better suited for benchmarking and testing of different image processing techniques. Specifically, tomographic reconstruction algorithms which employ 2D and 3D scanning geometries, can be rigorously analyzed using the software. TomoPhantom also provides a capability of obtaining analytical tomographic projections which further extends the applicability of software towards more realistic, free from the "inverse crime" testing. All core modules of the package are written in the C-OpenMP language and wrappers for Python and MATLAB are provided to enable easy access. Due to C-based multi-threaded implementation, volumetric phantoms of high spatial resolution can be obtained with computational efficiency.
Individualized localization and cortical surface-based registration of intracranial electrodes
Dykstra, Andrew R.; Chan, Alexander M.; Quinn, Brian T.; Zepeda, Rodrigo; Keller, Corey J.; Cormier, Justine; Madsen, Joseph R.; Eskandar, Emad N.; Cash, Sydney S.
2011-01-01
In addition to its widespread clinical use, the intracranial electroencephalogram (iEEG) is increasingly being employed as a tool to map the neural correlates of normal cognitive function as well as for developing neuroprosthetics. Despite recent advances, and unlike other established brain mapping modalities (e.g. functional MRI, magneto- and electroencephalography), registering the iEEG with respect to neuroanatomy in individuals – and coregistering functional results across subjects – remains a significant challenge. Here we describe a method which coregisters high-resolution preoperative MRI with postoperative computerized tomography (CT) for the purpose of individualized functional mapping of both normal and pathological (e.g., interictal discharges and seizures) brain activity. Our method accurately (within 3mm, on average) localizes electrodes with respect to an individual’s neuroanatomy. Furthermore, we outline a principled procedure for either volumetric or surface-based group analyses. We demonstrate our method in five patients with medically-intractable epilepsy undergoing invasive monitoring of the seizure focus prior to its surgical removal. The straight-forward application of this procedure to all types of intracranial electrodes, robustness to deformations in both skull and brain, and the ability to compare electrode locations across groups of patients makes this procedure an important tool for basic scientists as well as clinicians. PMID:22155045
Grand rounds: asbestos-related pericarditis in a boiler operator.
Abejie, Belayneh A; Chung, Eugene H; Nesto, Richard W; Kales, Stefanos N
2008-01-01
Occupational and environmental exposures to asbestos remain a public health problem even in developed countries. Because of the long latency in asbestos-related pathology, past asbestos exposure continues to contribute to incident disease. Asbestos most commonly produces pulmonary pathology, with asbestos-related pleural disease as the most common manifestation. Although the pleurae and pericardium share certain histologic characteristics, asbestos-related pericarditis is rarely reported. We present a 59-year-old man who worked around boilers for almost 30 years and was eventually determined to have calcific, constrictive pericarditis. He initially presented with an infectious exacerbation of chronic bronchitis. Chest radiographs demonstrated pleural and pericardial calcifications. Further evaluation with cardiac catheterization showed a hemodynamic picture consistent with constrictive pericarditis. A high-resolution computerized tomography scan of the chest demonstrated dense calcification in the pericardium, right pleural thickening and nodularity, right pleural plaque without calcification, and density in the right middle lobe. Pulmonary function testing showed mild obstruction and borderline low diffusing capacity. Based on the patient's occupational history, the presence of pleural pathology consistent with asbestos, previous evidence that asbestos can affect the pericardium, and absence of other likely explanations, we concluded that his pericarditis was asbestos-related. Similar to pleural thickening and plaque formation, asbestos may cause progressive fibrosis of the pericardium.
An Automatic and Robust Algorithm of Reestablishment of Digital Dental Occlusion
Chang, Yu-Bing; Xia, James J.; Gateno, Jaime; Xiong, Zixiang; Zhou, Xiaobo; Wong, Stephen T. C.
2017-01-01
In the field of craniomaxillofacial (CMF) surgery, surgical planning can be performed on composite 3-D models that are generated by merging a computerized tomography scan with digital dental models. Digital dental models can be generated by scanning the surfaces of plaster dental models or dental impressions with a high-resolution laser scanner. During the planning process, one of the essential steps is to reestablish the dental occlusion. Unfortunately, this task is time-consuming and often inaccurate. This paper presents a new approach to automatically and efficiently reestablish dental occlusion. It includes two steps. The first step is to initially position the models based on dental curves and a point matching technique. The second step is to reposition the models to the final desired occlusion based on iterative surface-based minimum distance mapping with collision constraints. With linearization of rotation matrix, the alignment is modeled by solving quadratic programming. The simulation was completed on 12 sets of digital dental models. Two sets of dental models were partially edentulous, and another two sets have first premolar extractions for orthodontic treatment. Two validation methods were applied to the articulated models. The results show that using our method, the dental models can be successfully articulated with a small degree of deviations from the occlusion achieved with the gold-standard method. PMID:20529735
Finite element method framework for RF-based through-the-wall mapping
NASA Astrophysics Data System (ADS)
Campos, Rafael Saraiva; Lovisolo, Lisandro; de Campos, Marcello Luiz R.
2017-05-01
Radiofrequency (RF) Through-the-Wall Mapping (TWM) employs techniques originally applied in X-Ray Computerized Tomographic Imaging to map obstacles behind walls. It aims to provide valuable information for rescuing efforts in damaged buildings, as well as for military operations in urban scenarios. This work defines a Finite Element Method (FEM) based framework to allow fast and accurate simulations of the reconstruction of floors blueprints, using Ultra High-Frequency (UHF) signals at three different frequencies (500 MHz, 1 GHz and 2 GHz). To the best of our knowledge, this is the first use of FEM in a TWM scenario. This framework allows quick evaluation of different algorithms without the need to assemble a full test setup, which might not be available due to budgetary and time constraints. Using this, the present work evaluates a collection of reconstruction methods (Filtered Backprojection Reconstruction, Direct Fourier Reconstruction, Algebraic Reconstruction and Simultaneous Iterative Reconstruction) under a parallel-beam acquisition geometry for different spatial sampling rates, number of projections, antenna gains and operational frequencies. The use of multiple frequencies assesses the trade-off between higher resolution at shorter wavelengths and lower through-the-wall penetration. Considering all the drawbacks associated with such a complex problem, a robust and reliable computational setup based on a flexible method such as FEM can be very useful.
[Lung involvement in systemic connective tissue diseases].
Plavec, Goran; Tomić, Ilija; Bihorac, Sanela; Kovacević, Gordana; Pavlica, Ljiljana; Cvetković, Gordana; Sikimić, Stevan; Milić, Rade
2008-09-01
Systemic connective tissue diseases (SCTD) are chronic inflammatory autoimmune disorders of unknown cause that can involve different organs and systems. Their course and prognosis are different. All of them can, more or less, involve the respiratory sistem. The aim of this study was to find out the frequency of respiratory simptoms, lung function disorders, radiography and high-resolution computerized tomography (HRCT) abnormalities, and their correlation with the duration of the disease and the applied treatment. In 47 non-randomised consecutive patients standard chest radiography, HRCT, and lung function tests were done. Hypoxemia was present in nine of the patients with respiratory simptoms (20%). In all of them chest radiography was normal. In five of these patients lung fibrosis was established using HRCT. Half of all the patients with SCTD had simptoms of lung involment. Lung function tests disorders of various degrees were found in 40% of the patients. The outcome and the degree of lung functin disorders were neither in correlation with the duration of SCTD nor with therapy used (p > 0.05 Spearmans Ro). Pulmonary fibrosis occures in about 10% of the patients with SCTD, and possibly not due to the applied treatment regimens. Hypoxemia could be a sing of existing pulmonary fibrosis in the absence of disorders on standard chest radiography.
Individualized localization and cortical surface-based registration of intracranial electrodes.
Dykstra, Andrew R; Chan, Alexander M; Quinn, Brian T; Zepeda, Rodrigo; Keller, Corey J; Cormier, Justine; Madsen, Joseph R; Eskandar, Emad N; Cash, Sydney S
2012-02-15
In addition to its widespread clinical use, the intracranial electroencephalogram (iEEG) is increasingly being employed as a tool to map the neural correlates of normal cognitive function as well as for developing neuroprosthetics. Despite recent advances, and unlike other established brain-mapping modalities (e.g. functional MRI, magneto- and electroencephalography), registering the iEEG with respect to neuroanatomy in individuals-and coregistering functional results across subjects-remains a significant challenge. Here we describe a method which coregisters high-resolution preoperative MRI with postoperative computerized tomography (CT) for the purpose of individualized functional mapping of both normal and pathological (e.g., interictal discharges and seizures) brain activity. Our method accurately (within 3mm, on average) localizes electrodes with respect to an individual's neuroanatomy. Furthermore, we outline a principled procedure for either volumetric or surface-based group analyses. We demonstrate our method in five patients with medically-intractable epilepsy undergoing invasive monitoring of the seizure focus prior to its surgical removal. The straight-forward application of this procedure to all types of intracranial electrodes, robustness to deformations in both skull and brain, and the ability to compare electrode locations across groups of patients makes this procedure an important tool for basic scientists as well as clinicians. Copyright © 2011 Elsevier Inc. All rights reserved.
Ballard, J C
1996-12-01
In a sample of 163 college undergraduates, the effects of task demand, noise, and anxiety on Continuous Performance Test (CPT) errors were evaluated with multiple regression and multivariate analysis of variance. Results indicated significantly more omission errors on the difficult task. Complex interaction effects of noise and self-reported anxiety yielded more omissions in quiet intermittent white noise, particularly for high-anxious subjects performing the difficult task. Anxiety levels tended to increase from pretest to posttest, particularly for low-anxious subjects in the quiet, difficult-task condition, while a decrease was seen for high-anxious subjects in the loud, easy-task condition. Commission errors were unrelated to any predictor variables, suggesting that "attention" cannot be considered a unitary phenomenon. The variety of direct and interactive effects on vigilance performance underscore the need for clinicians to use a variety of measures to assess attentional skills, to avoid diagnosis of attention deficits on the basis of a single computerized task performance, and to rule out anxiety and other contributors to poor vigilance task performance.
Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy
Kolokitha, Olga-Elpis
2007-01-01
Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468
Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.
Kolokitha, Olga-Elpis
2007-10-01
The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.
Comin, Eva; Catalan-Ramos, Arantxa; Iglesias-Rodal, Manuel; Grau, Maria; Del Val, Jose Luis; Consola, Alicia; Amado, Ester; Pons, Angels; Mata-Cases, Manel; Franzi, Alicia; Ciurana, Ramon; Frigola, Eva; Cos, Xavier; Davins, Josep; Verdu-Rotellar, Jose M
To evaluate the impact of computerized clinical practice guidelines on the management, diagnosis, treatment, control, and follow-up of the main cardiovascular risk factors: hypertension, hypercholesterolaemia, and type 2 diabetes mellitus. Pre-post controlled study. Catalonia, autonomous community located in north-eastern Spain. Individuals aged 35-74 years assigned to general practitioners of the Catalan Health Institute. The intervention group consisted of individuals whose general practitioners had accessed the computerized clinical practice guidelines at least twice a day, while the control group consisted of individuals whose general practitioner had never accessed the computerized clinical practice guidelines platform. The Chi-squared test was used to detect significant differences in the follow-up, control, and treatment variables for all three disorders (hypertension, hypercholesterolaemia, and type 2 diabetes mellitus) between individuals assigned to users and non-users of the computerized clinical practice guidelines, respectively. A total of 189,067 patients were included in this study, with a mean age of 56 years (standard deviation 12), and 55.5% of whom were women. Significant differences were observed in hypertension management, treatment and control; type 2 diabetes mellitus management, treatment and diagnoses, and the management and control of hypercholesterolaemia in both sexes. Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Outpatient Prescribing Errors and the Impact of Computerized Prescribing
Gandhi, Tejal K; Weingart, Saul N; Seger, Andrew C; Borus, Joshua; Burdick, Elisabeth; Poon, Eric G; Leape, Lucian L; Bates, David W
2005-01-01
Background Medication errors are common among inpatients and many are preventable with computerized prescribing. Relatively little is known about outpatient prescribing errors or the impact of computerized prescribing in this setting. Objective To assess the rates, types, and severity of outpatient prescribing errors and understand the potential impact of computerized prescribing. Design Prospective cohort study in 4 adult primary care practices in Boston using prescription review, patient survey, and chart review to identify medication errors, potential adverse drug events (ADEs) and preventable ADEs. Participants Outpatients over age 18 who received a prescription from 24 participating physicians. Results We screened 1879 prescriptions from 1202 patients, and completed 661 surveys (response rate 55%). Of the prescriptions, 143 (7.6%; 95% confidence interval (CI) 6.4% to 8.8%) contained a prescribing error. Three errors led to preventable ADEs and 62 (43%; 3% of all prescriptions) had potential for patient injury (potential ADEs); 1 was potentially life-threatening (2%) and 15 were serious (24%). Errors in frequency (n=77, 54%) and dose (n=26, 18%) were common. The rates of medication errors and potential ADEs were not significantly different at basic computerized prescribing sites (4.3% vs 11.0%, P=.31; 2.6% vs 4.0%, P=.16) compared to handwritten sites. Advanced checks (including dose and frequency checking) could have prevented 95% of potential ADEs. Conclusions Prescribing errors occurred in 7.6% of outpatient prescriptions and many could have harmed patients. Basic computerized prescribing systems may not be adequate to reduce errors. More advanced systems with dose and frequency checking are likely needed to prevent potentially harmful errors. PMID:16117752
NASA Technical Reports Server (NTRS)
Horton, W.; Kinsey, M.
1967-01-01
Computerized parts list system compiles and summarize all pertinent and available information on complex new systems. The parts list system consists of three computer subroutines - list of parts, parts numerical sequence list, and specifications list.
45 CFR 307.0 - Scope of this part.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) The requirement for computerized support enforcement systems; (b) The functional requirements that a statewide computerized support enforcement system must meet; (c) Security and confidentiality requirements... to approving an advance planning document (APD); (e) The requirements and procedures for the...
The Computerized Reference Department: Buying the Future.
ERIC Educational Resources Information Center
Kriz, Harry M.; Kok, Victoria T.
1985-01-01
Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…
11 CFR 9033.12 - Production of computerized information.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Disbursements made and reimbursements received for the cost of transportation, ground services and facilities...'s software capabilities, such as user guides, technical manuals, formats, layouts and other... software and the computerized information prepared or maintained by the committee. ...
Computerized tomography of the otic capsule and otoliths in the oyster toadfish, Opsanus tau.
Edds-Walton, Peggy L; Arruda, Julie; Fay, Richard R; Ketten, Darlene R
2015-02-01
The neurocranium of the toadfish (Opsanus tau) exhibits a distinct translucent region in the otic capsule (OC) that may have functional significance for the auditory pathway. This study used ultrahigh resolution computerized tomography (100 µm voxels) to compare the relative density of three sites along the OC (dorsolateral, midlateral, and ventromedial) and two reference sites (dorsal: supraoccipital crest; ventral: parasphenoid bone) in the neurocranium. Higher attenuation occurs where structural density is greater; thus, we compared the X-ray attenuations measured, which provided a measure of relative density. The maximum attenuation value was recorded for each of the five sites (x and y) on consecutive sections throughout the OC and for each of the three calcareous otoliths associated with the sensory maculae (lagena, saccule, and utricle) in the OC. All three otoliths had higher attenuations than any sites in the neurocranium. Both dorsal and ventral reference sites (supraoccipital crest and parasphenoid bone, respectively) had attenuation levels consistent with calcified bone and had relatively small, irregular variations along the length of the OC in all individuals. The lowest relative attenuations (lowest densities) occurred consistently at the three sites along the OC. In addition, the lowest attenuations measured along the OC occurred at the ventromedial site around the saccular otolith for all seven fish. The decrease in bone density along the OC is consistent with the hypothesis that there is a low-density channel in the skull to facilitate transmission of acoustic stimuli to the auditory endorgans of the ear. © 2014 Wiley Periodicals, Inc.
Analysis of high velocity impact on hybrid composite fan blades
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1979-01-01
Recent developments in the analysis of high velocity impact of composite blades are described, using a computerized capability which consists of coupling a composites mechanics code with the direct-time integration features of NASTRAN. The application of the capability to determine the linear dynamic response of an interply hybrid composite aircraft engine fan blade is described in detail. The results also show that the impact stresses reach sufficiently high magnitudes to cause failures in the impact region at early times of the impact event.
Franz, Annabel O; Harrop, Tiffany M; McCord, David M
2017-01-01
This study aimed to examine the construct validity of the Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF) interpersonal functioning scales (Ben-Porath & Tellegen, 2008/2011 ) using as a criterion measure the Computerized Adaptive Test of Personality Disorder-Static Form (CAT-PD-SF; Simms et al., 2011 ). Participants were college students (n = 98) recruited through the university subject pool. A series of a priori hypotheses were developed for each of the 6 interpersonal functioning scales of the MMPI-2-RF, expressed as predicted correlations with construct-relevant CAT-PD-SF scales. Of the 27 specific predictions, 21 were supported by substantial (≥ |.30|) correlations. The MMPI-2-RF Family Problems scale (FML) demonstrated the strongest correlations with CAT-PD-SF scales Anhedonia and Mistrust; Cynicism (RC3) was most highly correlated with Mistrust and Norm Violation; Interpersonal Passivity (IPP) was most highly correlated with Domineering and Rudeness; Social Avoidance (SAV) was most highly correlated with Social Withdrawal and Anhedonia; Shyness (SHY) was most highly correlated with Social Withdrawal and Anxioiusness; and Disaffiliativeness (DSF) was most highly correlated with Emotional Detachment and Mistrust. Results are largely consistent with hypotheses suggesting support for both models of constructs relevant to interpersonal functioning. Future research designed to more precisely differentiate Social Avoidance (SAV) and Shyness (SHY) is suggested.
Applications of computerized adaptive testing (CAT) to the assessment of headache impact.
Ware, John E; Kosinski, Mark; Bjorner, Jakob B; Bayliss, Martha S; Batenhorst, Alice; Dahlöf, Carl G H; Tepper, Stewart; Dowson, Andrew
2003-12-01
To evaluate the feasibility of computerized adaptive testing (CAT) and the reliability and validity of CAT-based estimates of headache impact scores in comparison with 'static' surveys. Responses to the 54-item Headache Impact Test (HIT) were re-analyzed for recent headache sufferers (n = 1016) who completed telephone interviews during the National Survey of Headache Impact (NSHI). Item response theory (IRT) calibrations and the computerized dynamic health assessment (DYNHA) software were used to simulate CAT assessments by selecting the most informative items for each person and estimating impact scores according to pre-set precision standards (CAT-HIT). Results were compared with IRT estimates based on all items (total-HIT), computerized 6-item dynamic estimates (CAT-HIT-6), and a developmental version of a 'static' 6-item form (HIT-6-D). Analyses focused on: respondent burden (survey length and administration time), score distributions ('ceiling' and 'floor' effects), reliability and standard errors, and clinical validity (diagnosis, level of severity). A random sample (n = 245) was re-assessed to test responsiveness. A second study (n = 1103) compared actual CAT surveys and an improved 'static' HIT-6 among current headache sufferers sampled on the Internet. Respondents completed measures from the first study and the generic SF-8 Health Survey; some (n = 540) were re-tested on the Internet after 2 weeks. In the first study, simulated CAT-HIT and total-HIT scores were highly correlated (r = 0.92) without 'ceiling' or 'floor' effects and with a substantial reduction (90.8%) in respondent burden. Six of the 54 items accounted for the great majority of item administrations (3603/5028, 77.6%). CAT-HIT reliability estimates were very high (0.975-0.992) in the range where 95% of respondents scored, and relative validity (RV) coefficients were high for diagnosis (RV = 0.87) and severity (RV = 0.89); patient-level classifications were accurate 91.3% for a diagnosis of migraine. For all three criteria of change, CAT-HIT scores were more responsive than all other measures. In the second study, estimates of respondent burden, item usage, reliability and clinical validity were replicated. The test-retest reliability of CAT-HIT was 0.79 and alternate forms coefficients ranged from 0.85 to 0.91. All correlations with the generic SF-8 were negative. CAT-based administrations of headache impact items achieved very large reductions in respondent burden without compromising validity for purposes of patient screening or monitoring changes in headache impact over time. IRT models and CAT-based dynamic health assessments warrant testing among patients with other conditions.
Reaction Time and Attention: Toward a New Standard in the Assessment of ADHD? A Pilot Study.
De la Torre, Gabriel G; Barroso, Juan M; León-Carrión, José; Mestre, Jose M; Bozal, Rocío Guil
2015-12-01
This pilot study shows results of an experiment comparing reaction times (RTs) and attentional performance between an ADHD group of 30 children and 30 controls, both Spanish speaking. The experiment was carried out using the Seville computerized neuropsychological battery (SNB). This study had two goals: One was to test sensitivity of SNB for attention deficits in ADHD and the second was to detect differences in RTs between ADHD and controls. Possible explanations and implications of such differences are also discussed. SNB computerized system was used to assess RTs and accuracy, and alternate forms of continuous performance task were used. Results showed high sensitivity of some of the SNB tests, especially cancellation tests. RTs were significantly different between groups. SNB represents a helpful tool for detection of attention deficits, and RT indices represent the most significant variable in differentiation of both groups studied. © The Author(s) 2012.
Standardization in software conversion of (ROM) estimating
NASA Technical Reports Server (NTRS)
Roat, G. H.
1984-01-01
Technical problems and their solutions comprise by far the majority of work involved in space simulation engineering. Fixed price contracts with schedule award fees are becoming more and more prevalent. Accurate estimation of these jobs is critical to maintain costs within limits and to predict realistic contract schedule dates. Computerized estimating may hold the answer to these new problems, though up to now computerized estimating has been complex, expensive, and geared to the business world, not to technical people. The objective of this effort was to provide a simple program on a desk top computer capable of providing a Rough Order of Magnitude (ROM) estimate in a short time. This program is not intended to provide a highly detailed breakdown of costs to a customer, but to provide a number which can be used as a rough estimate on short notice. With more debugging and fine tuning, a more detailed estimate can be made.
Multiple-energy Techniques in Industrial Computerized Tomography
DOE R&D Accomplishments Database
Schneberk, D.; Martz, H.; Azevedo, S.
1990-08-01
Considerable effort is being applied to develop multiple-energy industrial CT techniques for materials characterization. Multiple-energy CT can provide reliable estimates of effective Z (Z{sub eff}), weight fraction, and rigorous calculations of absolute density, all at the spatial resolution of the scanner. Currently, a wide variety of techniques exist for CT scanners, but each has certain problems and limitations. Ultimately, the best multi-energy CT technique would combine the qualities of accuracy, reliability, and wide range of application, and would require the smallest number of additional measurements. We have developed techniques for calculating material properties of industrial objects that differ somewhat from currently used methods. In this paper, we present our methods for calculating Z{sub eff}, weight fraction, and density. We begin with the simplest case -- methods for multiple-energy CT using isotopic sources -- and proceed to multiple-energy work with x-ray machine sources. The methods discussed here are illustrated on CT scans of PBX-9502 high explosives, a lexan-aluminum phantom, and a cylinder of glass beads used in a preliminary study to determine if CT can resolve three phases: air, water, and a high-Z oil. In the CT project at LLNL, we have constructed several CT scanners of varying scanning geometries using {gamma}- and x-ray sources. In our research, we employed two of these scanners: pencil-beam CAT for CT data using isotopic sources and video-CAT equipped with an IRT micro-focal x-ray machine source.
Patterns of Emphysema Heterogeneity
Valipour, Arschang; Shah, Pallav L.; Gesierich, Wolfgang; Eberhardt, Ralf; Snell, Greg; Strange, Charlie; Barry, Robert; Gupta, Avina; Henne, Erik; Bandyopadhyay, Sourish; Raffy, Philippe; Yin, Youbing; Tschirren, Juerg; Herth, Felix J.F.
2016-01-01
Background Although lobar patterns of emphysema heterogeneity are indicative of optimal target sites for lung volume reduction (LVR) strategies, the presence of segmental, or sublobar, heterogeneity is often underappreciated. Objective The aim of this study was to understand lobar and segmental patterns of emphysema heterogeneity, which may more precisely indicate optimal target sites for LVR procedures. Methods Patterns of emphysema heterogeneity were evaluated in a representative cohort of 150 severe (GOLD stage III/IV) chronic obstructive pulmonary disease (COPD) patients from the COPDGene study. High-resolution computerized tomography analysis software was used to measure tissue destruction throughout the lungs to compute heterogeneity (≥ 15% difference in tissue destruction) between (inter-) and within (intra-) lobes for each patient. Emphysema tissue destruction was characterized segmentally to define patterns of heterogeneity. Results Segmental tissue destruction revealed interlobar heterogeneity in the left lung (57%) and right lung (52%). Intralobar heterogeneity was observed in at least one lobe of all patients. No patient presented true homogeneity at a segmental level. There was true homogeneity across both lungs in 3% of the cohort when defining heterogeneity as ≥ 30% difference in tissue destruction. Conclusion Many LVR technologies for treatment of emphysema have focused on interlobar heterogeneity and target an entire lobe per procedure. Our observations suggest that a high proportion of patients with emphysema are affected by interlobar as well as intralobar heterogeneity. These findings prompt the need for a segmental approach to LVR in the majority of patients to treat only the most diseased segments and preserve healthier ones. PMID:26430783
Retinoic acid-induced alveolar cellular growth does not improve function after right pneumonectomy.
Dane, D Merrill; Yan, Xiao; Tamhane, Rahul M; Johnson, Robert L; Estrera, Aaron S; Hogg, Deborah C; Hogg, Richard T; Hsia, Connie C W
2004-03-01
To determine whether all-trans retinoic acid (RA) treatment enhances lung function during compensatory lung growth in fully mature animals, adult male dogs (n = 4) received 2 mg x kg(-1) x day(-1) po RA 4 days/wk beginning the day after right pneumonectomy (R-PNX, 55-58% resection). Litter-matched male R-PNX controls (n = 4) received placebo. After 3 mo, transpulmonary pressure (TPP)-lung volume relationship, diffusing capacities for carbon monoxide and nitric oxide, cardiac output, and septal volume (V(tiss-RB)) were measured under anesthesia by a rebreathing technique at two lung volumes. Lung air and tissue volumes (V(air-CT) and V(tiss-CT)) were also measured from high-resolution computerized tomographic (CT) scans at a constant TPP. In RA-treated dogs compared with controls, TPP-lung volume relationships were similar. Diffusing capacities for carbon monoxide and nitric oxide were significantly impaired at a lower lung volume but similar at a high lung volume. Whereas V(tiss-RB) was significantly lower at both lung volumes in RA-treated animals, V(air-CT) and V(tiss-CT) were not different between groups; results suggest uneven distribution of ventilation consistent with distortion of alveolar geometry and/or altered small airway function induced by RA. We conclude that RA does not improve resting pulmonary function during the early months after R-PNX despite histological evidence of its action in enhancing alveolar cellular growth in the remaining lung.
Patel, Vijay M; Rains, Anna W; Clark, Christopher T
2016-01-01
To reduce the rate of inappropriate red blood cell transfusion, a provider education program, followed by alerts in the computerized provider order entry system (CPOE), was established to encourage AABB transfusion guidelines. Metrics were established for nonemergent inpatient transfusions. Service lines with high order volume were targeted with formal education regarding AABB 2012 transfusion guidelines. Transfusion orders were reviewed in real time with email communications sent to ordering providers falling outside of AABB recommendations. After 12 months of provider education, alerts were activated in CPOE. With provider education alone, the incidence of pretransfusion hemoglobin levels greater than 8 g/dL decreased from 16.64% to 6.36%, posttransfusion hemoglobin levels greater than 10 g/dL from 14.03% to 3.78%, and number of nonemergent two-unit red blood cell orders from 45.26% to 22.66%. Red blood cell utilization decreased by 13%. No additional significant reduction in nonemergent two-unit orders was observed with CPOE alerts. Provider education, an effective and low-cost method, should be considered as a first-line method for reducing inappropriate red blood cell transfusion rates in stable adult inpatients. Alerts in the computerized order entry system did not significantly lower the percentage of two-unit red blood cells orders but may help to maintain educational efforts.
Computerized analysis of fetal heart rate variability signal during the stages of labor.
Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta
2016-03-01
To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (< 0.05). Statistically significant differences were seen between baseline FHR, MF and HF (P < 0.001), in which the first two were reduced and the third was increased when compared between pre-labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.
Wares, Joanna R; Hoke, Kathy W; Walker, William; Franke, Laura Manning; Cifu, David X; Carne, William; Ford-Smith, Cheryl
2015-01-01
The high rate of blast exposures experienced by U.S. servicemembers (SMs) during the recent conflicts in Iraq and Afghanistan has resulted in frequent combat-related mild traumatic brain injuries (mTBIs). Dizziness and postural instability can persist after mTBI as a component of postconcussion syndrome, but also occur among the somatic complaints of posttraumatic stress disorder (PTSD). The goals of this study were to examine the use of computerized posturography (CPT) to objectively characterize chronic balance deficits after mTBI and to explore the utility of CPT in distinguishing between combat and blast-exposed participants with and without mTBI and PTSD. Data were analyzed from a subject pool of 166 combat-exposed SMs and Veterans who had a blast experience within the past 2 yr while deployed. Using nonparametric tests and measures of impairment, we found that balance was deficient in participants diagnosed with mTBI with posttraumatic amnesia (PTA) or PTSD versus those with neither and that deficits were amplified for participants with both diagnoses. In addition, unique deficiencies were found using CPT for individuals having isolated mTBI with PTA and isolated PTSD. Computerized balance assessment offers an objective technique to examine the physiologic effects and provide differentiation between participants with combat-associated mTBI and PTSD.
Documentation of validity for the AT-SAT computerized test battery. Volume 2
DOT National Transportation Integrated Search
2001-03-01
This document is a comprehensive report on a large-scale research project to develop and validate a : computerized selection battery to hire Air Traffic Control Specialists (ATCSs) for the Federal Aviation : Administration (FAA). The purpose of this ...
Documentation of validity for the AT-SAT computerized test battery. Volume 1
DOT National Transportation Integrated Search
2001-03-01
This document is a comprehensive report on a large-scale research project to develop and validate a : computerized selection battery to hire Air Traffic Control Specialists (ATCSs) for the Federal Aviation : Administration (FAA). The purpose of this ...
Computerized Budget Monitoring.
ERIC Educational Resources Information Center
Stein, Julian U.; Rowe, Joe N.
1989-01-01
This article discusses the importance of budget monitoring in fiscal management; describes ways in which computerized budget monitoring increases accuracy, efficiency, and flexibility; outlines steps in the budget process; and presents sample reports, generated using the Lotus 1-2-3 spreadsheet and graphics program. (IAH)
Enhancing GDOT's Computerized Pavement Condition Evaluation System for Pavement Condition Survey
DOT National Transportation Integrated Search
2017-09-01
The Computerized Pavement Condition Evaluation System (COPACES) is a software tool that has been used by the Georgia Department of Transportation (GDOT) for its statewide pavement condition survey since the late 1990s. The previous version was releas...
DOT National Transportation Integrated Search
1995-02-01
COGSCREEN is a computerized test battery developed for the Federal Aviation Administration as an airman neuropsychological screening instrument for cognitive functioning. This study explored a multifaceted application of the sensitivity of the batter...
Computerized Cognition Laboratory.
ERIC Educational Resources Information Center
Motes, Michael A.; Wiegmann, Douglas A.
1999-01-01
Describes a software package entitled the "Computerized Cognition Laboratory" that helps integrate the teaching of cognitive psychology and research methods. Allows students to explore short-term memory, long-term memory, and decision making. Can also be used to teach the application of several statistical procedures. (DSK)
Nursing informatics: the trend of the future.
Nagelkerk, J; Ritola, P M; Vandort, P J
1998-01-01
Nursing informatics is a combination of computer, information, and nursing sciences. This new and expanding field addresses the efficient and effective use of information for nurses. Preparing nurses for computerization is essential to confront an explosion of sophisticated computerized technology in the workplace. It is critical in a competitive health care market for preparing nurses to use the most cost-effective methods. A model is presented that identifies six essential factors for preparing nurses for computerization. Strong leadership, effective communication, organized training sessions, established time frames, planned change, and tailored software are the essential factors to consider for development of a successful educational program.
An analysis of computerization in primary care practices.
Condon, James V; Smith, Sherry P
2002-12-01
To remain profitable, primary care practices, the front-line health care providers, must provide excellent patient care and reduce expenses while providing payers with accurate data. Many primary care practices have turned to computer technology to achieve these goals. This study examined the degree of computerization of primary care providers in the Augusta, Georgia, metropolitan area as well as the level of awareness of the Health Insurance Portability and Accountability Act (HIPAA) by primary care providers and its potential effect on their future computerization plans. The study's findings are presented and discussed as well as a number of recommendations for practice managers.
THE VALIDITY OF HUMAN AND COMPUTERIZED WRITING ASSESSMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ronald L. Boring
2005-09-01
This paper summarizes an experiment designed to assess the validity of essay grading between holistic and analytic human graders and a computerized grader based on latent semantic analysis. The validity of the grade was gauged by the extent to which the student’s knowledge of the topic correlated with the grader’s expert knowledge. To assess knowledge, Pathfinder networks were generated by the student essay writers, the holistic and analytic graders, and the computerized grader. It was found that the computer generated grades more closely matched the definition of valid grading than did human generated grades.
Claessen, Michiel H G; van der Ham, Ineke J M; van Zandvoort, Martine J E
2015-01-01
The tablet computer initiates an important step toward computerized administration of neuropsychological tests. Because of its lack of standardization, the Corsi Block-Tapping Task could benefit from advantages inherent to computerization. This task, which requires reproduction of a sequence of movements by tapping blocks as demonstrated by an examiner, is widely used as a representative of visuospatial attention and working memory. The aim was to validate a computerized version of the Corsi Task (e-Corsi) by comparing recall accuracy to that on the standard task. Forty university students (Mage = 22.9 years, SD = 2.7 years; 20 female) performed the standard Corsi Task and the e-Corsi on an iPad 3. Results showed higher accuracy in forward reproduction on the standard Corsi compared with the e-Corsi, whereas backward performance was comparable. These divergent performance patterns on the 2 versions (small-to-medium effect sizes) are explained as a result of motor priming and interference effects. This finding implies that computerization has serious consequences for the cognitive concepts that the Corsi Task is assumed to assess. Hence, whereas the e-Corsi was shown to be useful with respect to administration and registration, these findings also stress the need for reconsideration of the underlying theoretical concepts of this task.
2013-01-01
Objective. This study compared the relationship between computer experience and performance on computerized cognitive tests and a traditional paper-and-pencil cognitive test in a sample of older adults (N = 634). Method. Participants completed computer experience and computer attitudes questionnaires, three computerized cognitive tests (Useful Field of View (UFOV) Test, Road Sign Test, and Stroop task) and a paper-and-pencil cognitive measure (Trail Making Test). Multivariate analysis of covariance was used to examine differences in cognitive performance across the four measures between those with and without computer experience after adjusting for confounding variables. Results. Although computer experience had a significant main effect across all cognitive measures, the effect sizes were similar. After controlling for computer attitudes, the relationship between computer experience and UFOV was fully attenuated. Discussion. Findings suggest that computer experience is not uniquely related to performance on computerized cognitive measures compared with paper-and-pencil measures. Because the relationship between computer experience and UFOV was fully attenuated by computer attitudes, this may imply that motivational factors are more influential to UFOV performance than computer experience. Our findings support the hypothesis that computer use is related to cognitive performance, and this relationship is not stronger for computerized cognitive measures. Implications and directions for future research are provided. PMID:22929395
Reading Comprehension: A Computerized Intervention with Primary-age Poor Readers.
Horne, Joanna Kathryn
2017-05-01
The current study investigates the effectiveness of a computerized reading comprehension programme on the reading accuracy, reading comprehension and reading rate of primary-age poor readers. There is little published literature relating to computerized reading interventions in UK primary schools, and no previous studies have investigated the Comprehension Booster programme. Thirty-eight children (26 boys and 12 girls; aged 6:7 to 11:0) from two schools in East Yorkshire, UK, took part. Half of the participants (the intervention group) undertook the Comprehension Booster programme for a 6-week period, whilst the other half (the control group) continued with their usual teaching. Significant effects of the intervention were found, with increases in reading accuracy and reading comprehension for the intervention group. It is concluded that computerized reading programmes can be effective in improving reading skills, and these are particularly useful for pupils with reading difficulties in disadvantaged areas, where resources are limited and family support in reading is lower. However, such programmes are not a replacement for good teaching, and regular monitoring of children with reading difficulties is required. Further research is necessary to compare the programme used here to other conventional and computerized intervention programmes, using a larger sample. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
A comparison of computer-assisted and manual wound size measurement.
Thawer, Habiba A; Houghton, Pamela E; Woodbury, M Gail; Keast, David; Campbell, Karen
2002-10-01
Accurate and precise wound measurements are a critical component of every wound assessment. To examine the reliability and validity of a new computerized technique for measuring human and animal wounds, chronic human wounds (N = 45) and surgical animal wounds (N = 38) were assessed using manual and computerized techniques. Using intraclass correlation coefficients, intrarater and interrater reliability of surface area measurements obtained using the computerized technique were compared to those obtained using acetate tracings and planimetry. A single measurement of surface area using either technique produced excellent intrarater and interrater reliability for both human and animal wounds, but the computerized technique was more precise than the manual technique for measuring the surface area of animal wounds. For both types of wounds and measurement techniques, intrarater and interrater reliability improved when the average of three repeated measurements was obtained. The precision of each technique with human wounds and the precision of the manual technique with animal wounds also improved when three repeated measurement results were averaged. Concurrent validity between the two techniques was excellent for human wounds but poor for the smaller animal wounds, regardless of whether single or the average of three repeated surface area measurements was used. The computerized technique permits reliable and valid assessment of the surface area of both human and animal wounds.
In person versus Computer Screening for Intimate Partner Violence Among Pregnant Patients
Dado, Diane; Schussler, Sara; Hawker, Lynn; Holland, Cynthia L.; Burke, Jessica G.; Cluss, Patricia A.
2012-01-01
Objective To compare in person versus computerized screening for intimate partner violence (IPV) in a hospital-based prenatal clinic and explore women’s assessment of the screening methods. Methods We compared patient IPV disclosures on a computerized questionnaire to audio-taped first obstetric visits with an obstetric care provider and performed semi-structured interviews with patient participants who reported experiencing IPV. Results Two-hundred and fifty patient participants and 52 provider participants were in the study. Ninety-one (36%) patients disclosed IPV either via computer or in person. Of those who disclosed IPV, 60 (66%) disclosed via both methods, but 31 (34%) disclosed IPV via only one of the two methods. Twenty-three women returned for interviews. They recommended using both types together. While computerized screening was felt to be non-judgmental and more anonymous, in person screening allowed for tailored questioning and more emotional connection with the provider. Conclusion Computerized screening allowed disclosure without fear of immediate judgment. In person screening allows more flexibility in wording of questions regarding IPV and opportunity for interpersonal rapport. Practice Implications Both computerized or self-completed screening and in person screening is recommended. Providers should address IPV using non-judgmental, descriptive language, include assessments for psychological IPV, and repeat screening in person, even if no patient disclosure occurs via computer. PMID:22770815
In person versus computer screening for intimate partner violence among pregnant patients.
Chang, Judy C; Dado, Diane; Schussler, Sara; Hawker, Lynn; Holland, Cynthia L; Burke, Jessica G; Cluss, Patricia A
2012-09-01
To compare in person versus computerized screening for intimate partner violence (IPV) in a hospital-based prenatal clinic and explore women's assessment of the screening methods. We compared patient IPV disclosures on a computerized questionnaire to audio-taped first obstetric visits with an obstetric care provider and performed semi-structured interviews with patient participants who reported experiencing IPV. Two-hundred and fifty patient participants and 52 provider participants were in the study. Ninety-one (36%) patients disclosed IPV either via computer or in person. Of those who disclosed IPV, 60 (66%) disclosed via both methods, but 31 (34%) disclosed IPV via only one of the two methods. Twenty-three women returned for interviews. They recommended using both types together. While computerized screening was felt to be non-judgmental and more anonymous, in person screening allowed for tailored questioning and more emotional connection with the provider. Computerized screening allowed disclosure without fear of immediate judgment. In person screening allows more flexibility in wording of questions regarding IPV and opportunity for interpersonal rapport. Both computerized or self-completed screening and in person screening is recommended. Providers should address IPV using non-judgmental, descriptive language, include assessments for psychological IPV, and repeat screening in person, even if no patient disclosure occurs via computer. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Tourangeau, Roger; And Others
This manual was produced to familiarize data users with the procedures followed in data collection and processing of the fifth follow-up survey of the National Longitudinal Survey of the High School Class of 1972 (NLS-72) and to provide documentation for use of the file. The data file is a computerized data base, which is available on magnetic…
Wong, Diane K.; Lee, Bai-Yu; Horwitz, Marcus A.; Gibson, Bradford W.
1999-01-01
Iron plays a critical role in the pathophysiology of Mycobacterium tuberculosis. To gain a better understanding of iron regulation by this organism, we have used two-dimensional (2-D) gel electrophoresis, mass spectrometry, and database searching to study protein expression in M. tuberculosis under conditions of high and low iron concentration. Proteins in cellular extracts from M. tuberculosis Erdman strain grown under low-iron (1 μM) and high-iron (70 μM) conditions were separated by 2-D polyacrylamide gel electrophoresis, which allowed high-resolution separation of several hundred proteins, as visualized by Coomassie staining. The expression of at least 15 proteins was induced, and the expression of at least 12 proteins was decreased under low-iron conditions. In-gel trypsin digestion was performed on these differentially expressed proteins, and the digestion mixtures were analyzed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry to determine the molecular masses of the resulting tryptic peptides. Partial sequence data on some of the peptides were obtained by using after source decay and/or collision-induced dissociation. The fragmentation data were used to search computerized peptide mass and protein sequence databases for known proteins. Ten iron-regulated proteins were identified, including Fur and aconitase proteins, both of which are known to be regulated by iron in other bacterial systems. Our study shows that, where large protein sequence databases are available from genomic studies, the combined use of 2-D gel electrophoresis, mass spectrometry, and database searching to analyze proteins expressed under defined environmental conditions is a powerful tool for identifying expressed proteins and their physiologic relevance. PMID:9864233
Computerized Adaptive Testing: From Inquiry to Operation [Book Review].
ERIC Educational Resources Information Center
Gierl, Mark J.
1998-01-01
This book documents the research, development, and implementation efforts that allowed the U.S. Department of Defense to initiate the Computerized Adaptive Testing Armed Services Vocational Aptitude Battery Program for enlistment testing. Traces the history of this program over 30 years. (SLD)
NASA Technical Reports Server (NTRS)
Leaf, C. F.
1975-01-01
A procedure is described whereby the correlation between: (1) satellite derived snow-cover depletion and (2) residual snowpack water equivalent, can be used to update computerized residual flow forecasts for the Conejos River in southern Colorado.
Computerized Drug Information Services
ERIC Educational Resources Information Center
And Others; Smith, Daniel R.
1972-01-01
To compare computerized services in chemistry, pharmacology, toxicology, and clinical medicine of pharmaceutical interest, equivalent profiles were run on magnetic tape files of CA-Condensates," CBAC," Excerpta Medica," MEDLARS" and Ringdoc." The results are tabulated for overlap of services, relative speed of citing references, and unique…
Computerized Fleet Maintenance.
ERIC Educational Resources Information Center
Cataldo, John J.
The computerization of school bus maintenance records by the Niskayuna (New York) Central School District enabled the district's transportation department to engage in management practices resulting in significant savings. The district obtains computer analyses of the work performed on all vehicles, including time spent, parts, labor, costs,…
Computerizing Maintenance Management Improves School Processes.
ERIC Educational Resources Information Center
Conroy, Pat
2002-01-01
Describes how a Computerized Maintenance Management System (CMMS), a centralized maintenance operations database that facilitates work order procedures and staff directives, can help individual school campuses and school districts to manage maintenance. Presents the benefits of CMMS and things to consider in CMMS selection. (EV)
Sustaining Indigenous Languages in Cyberspace.
ERIC Educational Resources Information Center
Cazden, Courtney B.
This paper describes how certain types of electronic technologies, specifically CD-ROMs, computerized databases, and telecommunications networks, are being incorporated into language and culture revitalization projects in Alaska and around the Pacific. The paper presents two examples of CD-ROMs and computerized databases from Alaska, describing…
Patel, Minal R; Vichich, Jennifer; Lang, Ian; Lin, Jessica; Zheng, Kai
2017-04-01
The introduction of health information technology systems, electronic health records in particular, is changing the nature of how clinicians interact with patients. Lack of knowledge remains on how best to integrate such systems in the exam room. The purpose of this systematic review was to (1) distill "best" behavioral and communication practices recommended in the literature for clinicians when interacting with patients in the presence of computerized systems during a clinical encounter, (2) weigh the evidence of each recommendation, and (3) rank evidence-based recommendations for electronic health record communication training initiatives for clinicians. We conducted a literature search of 6 databases, resulting in 52 articles included in the analysis. We extracted information such as study setting, research design, sample, findings, and implications. Recommendations were distilled based on consistent support for behavioral and communication practices across studies. Eight behavioral and communication practices received strong support of evidence in the literature and included specific aspects of using computerized systems to facilitate conversation and transparency in the exam room, such as spatial (re)organization of the exam room, maintaining nonverbal communication, and specific techniques that integrate the computerized system into the visit and engage the patient. Four practices, although patient-centered, have received insufficient evidence to date. We developed an evidence base of best practices for clinicians to maintain patient-centered communications in the presence of computerized systems in the exam room. Further work includes development and empirical evaluation of evidence-based guidelines to better integrate computerized systems into clinical care. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
A new color vision test to differentiate congenital and acquired color vision defects.
Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak
2007-07-01
To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.
The effectiveness of computerized drug-lab alerts: a systematic review and meta-analysis.
Bayoumi, Imaan; Al Balas, Mosab; Handler, Steven M; Dolovich, Lisa; Hutchison, Brian; Holbrook, Anne
2014-06-01
Inadequate lab monitoring of drugs is a potential cause of ADEs (adverse drug events) which is remediable. To determine the effectiveness of computerized drug-lab alerts to improve medication-related outcomes. Citations from the Computerized Clinical Decision Support System Systematic Review (CCDSSR) and MMIT (Medications Management through Health Information Technology) databases, which had searched MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, International Pharmaceutical Abstracts from 1974 to March 27, 2013. Randomized controlled trials (RCTs) of clinician-targeted computerized drug lab alerts conducted in any healthcare setting. Two reviewers performed full text review to determine study eligibility. A single reviewer abstracted data and evaluated validity of included studies using Cochrane handbook domains. Thirty-six studies met the inclusion criteria (25 single drug studies with 22,504 participants, 14 targeting anticoagulation; 11 multi-drug studies with 56,769 participants). ADEs were reported as an outcome in only four trials, all targeting anticoagulants. Computerized drug-lab alerts did not reduce ADEs (OR 0.89, 95% CI 0.79-1.00, p=0.05), length of hospital stay (SMD 0.00, 95%CI -0.93 to 0.93, p=0.055, 1 study), likelihood of hypoglycemia (OR 1.29, 95% CI 0.31-5.37) or likelihood of bleeding, but were associated with increased likelihood of prescribing changes (OR 1.73, 95% CI 1.21-2.47) or lab monitoring (OR 1.47, 95% confidence interval 1.12-1.94) in accordance with the alert. There is no evidence that computerized drug-lab alerts are associated with important clinical benefits, but there is evidence of improvement in selected clinical surrogate outcomes (time in therapeutic range for vitamin K antagonists), and changes in process outcomes (lab monitoring and prescribing decisions). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Mullen, Kristin H; Berry, Donna L; Zierler, Brenda K
2004-09-01
To determine the acceptability and usability of a computerized quality-of-life (QOL) and symptom assessment tool and the graphically displayed QOL and symptom output in an ambulatory radiation oncology clinic. Descriptive, cross-sectional. Radiation oncology clinic located in an urban university medical center. 45 patients with cancer being evaluated for radiation therapy and 10 clinicians, who submitted 12 surveys. Acceptability of the computerized assessment was measured with an online, 16-item, Likert-style survey delivered as 45 patients undergoing radiation therapy completed a 25-item QOL and symptom assessment. Usability of the graphic output was assessed with clinician completion of a four-item paper survey. Acceptability and usability of computerized patient assessment. The patient acceptability survey indicated that 70% (n = 28) liked computers and 10% (n = 4) did not. The program was easy to use for 79% (n = 26), easy to understand for 91% (n = 30), and enjoyable for 71% (n = 24). Seventy-six percent (n = 25) believed that the amount of time needed to complete the computerized survey was acceptable. Sixty-six percent (n = 21) responded that they were satisfied with the program, and none of the participants chose the very dissatisfied response. Eighty-three percent (n = 10) of the clinicians found the graphic output helpful in promoting communication with patients, 75% (n = 9) found the output report helpful in identifying appropriate areas of QOL deficits or concerns, and 83% (n = 10) indicated that the output helped guide clinical interactions with patients. The computer-based QOL and symptom assessment tool is acceptable to patients, and the graphically displayed QOL and symptom output is useful to radiation oncology nurses and physicians. Wider application of computerized patient-generated data can continue in various cancer settings and be tested for clinical and organizational outcomes.
Evaluation of an ontology-based system for computerized cognitive rehabilitation.
Alloni, Anna; Quaglini, Silvana; Panzarasa, Silvia; Sinforiani, Elena; Bernini, Sara
2018-07-01
This paper describes the results of a randomized clinical trial about the effectiveness of a computerized rehabilitation treatment on a sample of 31 patients affected by Parkinson disease. Computerized exercises were administered by the therapists to the intervention group (n = 17) through the CoRe tool, which automatically generates a big variety of exercises leveraging on a stimuli set (words, sounds and images) organized into a dedicated ontology. A battery of standard neuropsychological tests was performed for patients' assessment at baseline, after the treatment (that lasted 1 month), and after 6 months from the treatment stop. The control group underwent a sham intervention. Results show a statistically significant clinical benefit from computerized rehabilitation with respect to sham treatment. For the intervention group, response time and response accuracy were integrated into a weighted score that accounts also for the specific cognitive burden of each exercise. Differently from the control group, the majority of patients in the intervention group showed an improvement in that score, more marked in the first week of treatment, and which lasts for the entire treatment period, which could account both for a quick learning effect and for an improvement of cognitive conditions. Good usability of CoRe, already observed in previous studies, was confirmed by the present trial, where the percentage of protocol completion in the intervention group is very high (all but one patient are above 90%). The CoRe system showed to be effective to improve some cognitive abilities in patients with Parkinson disease. However, after the end of the training, the benefit is hardly maintained over time. These findings support the implementation of CoRe in the clinical routine and the continuation of the treatment after discharge through the use of a homecare version of the system. Copyright © 2018 Elsevier B.V. All rights reserved.
Rousseau, Marie-Claude; Conus, Florence; Li, Jun; Parent, Marie-Élise; El-Zein, Mariam
2014-01-09
Vaccination registries have undoubtedly proven useful for estimating vaccination coverage as well as examining vaccine safety and effectiveness. However, their use for population health research is often limited. The Bacillus Calmette-Guérin (BCG) Vaccination Registry for the Canadian province of Québec comprises some 4 million vaccination records (1926-1992). This registry represents a unique opportunity to study potential associations between BCG vaccination and various health outcomes. So far, such studies have been hampered by the absence of a computerized version of the registry. We determined the completeness and accuracy of the recently computerized BCG Vaccination Registry, as well as examined its linkability with demographic and administrative medical databases. Two systematically selected verification samples, each representing ~0.1% of the registry, were used to ascertain accuracy and completeness of the electronic BCG Vaccination Registry. Agreement between the paper [listings (n = 4,987 records) and vaccination certificates (n = 4,709 records)] and electronic formats was determined along several nominal and BCG-related variables. Linkage feasibility with the Birth Registry (probabilistic approach) and provincial Healthcare Registration File (deterministic approach) was examined using nominal identifiers for a random sample of 3,500 individuals born from 1961 to 1974 and BCG vaccinated between 1970 and 1974. Exact agreement was observed for 99.6% and 81.5% of records upon comparing, respectively, the paper listings and vaccination certificates to their corresponding computerized records. The proportion of successful linkage was 77% with the Birth Registry, 70% with the Healthcare Registration File, 57% with both, and varied by birth year. Computerization of this Registry yielded excellent results. The registry was complete and accurate, and linkage with administrative databases was highly feasible. This study represents the first step towards assembling large scale population-based epidemiological studies which will enable filling important knowledge gaps on the potential health effects of early life non-specific stimulation of the immune function, as resulting from BCG vaccination.
Jiménez-García, Rodrigo; Hernandez-Barrera, Valentín; Rodríguez-Rieiro, Cristina; Carrasco Garrido, Pilar; López de Andres, Ana; Jimenez-Trujillo, Isabel; Esteban-Vasallo, María D; Domínguez-Berjón, Maria Felicitas; de Miguel-Diez, Javier; Astray-Mochales, Jenaro
2014-07-31
We aim to compare influenza vaccination coverages obtained using two different methods; a population based computerized vaccination registry and self-reported influenza vaccination status as captured by a population survey. The study was conducted in the Autonomous Community of Madrid (ACM), Spain, and refers to the 2011/12 influenza vaccination campaign. Information on influenza vaccination status according to a computerized registry was extracted from the SISPAL database and crossed with the electronic clinical records in primary care (ECRPC). Self-reported vaccine uptake was obtained from subjects living in the ACM included in the 2011-12 Spanish National Health Survey (SNHS). Independent study variables included: age, sex, immigrant status and the presence of high risk chronic conditions. Vaccination coverages were calculated according to study variables. Crude and adjusted prevalence ratios were computed to assess concordance. The study population included 5,245,238 adults living in the ACM in year 2011 with an individual ECRPC and 1449 adult living the ACM and interviewed in the SNHS from October 2011 to June 2012. The weighted vaccination coverage for the study population according to self-reported data was 19.77% and 15.04% from computerized registries resulting in a crude prevalence ratio (cPR) of 1.31 (95% CI 1.20-1.44) so self-reported data significantly overestimated 31% the registry coverage. Self-reported coverages are always higher than registry based coverages when the study population is stratified by the study variables. Self-reported overestimation was higher among men than women, younger age groups, immigrants and those without chronic conditions. Both methods provide the most concordant estimations for the target population of the influenza vaccine. Self-report influenza vaccination uptake overestimates vaccination registries coverages. The validity of self-report seems to be negatively affected by socio-demographic variables and the absence of chronic conditions. Possible strategies must be considered and implemented to improve both coverage estimation methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, W; Wang, J; Zhang, H
Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss ormore » gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that computerized PET/CT image analysis holds great potential to improve the accuracy in evaluation of tumor response. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less
Barker, Jocelyn; Hoogi, Assaf; Depeursinge, Adrien; Rubin, Daniel L
2016-05-01
Computerized analysis of digital pathology images offers the potential of improving clinical care (e.g. automated diagnosis) and catalyzing research (e.g. discovering disease subtypes). There are two key challenges thwarting computerized analysis of digital pathology images: first, whole slide pathology images are massive, making computerized analysis inefficient, and second, diverse tissue regions in whole slide images that are not directly relevant to the disease may mislead computerized diagnosis algorithms. We propose a method to overcome both of these challenges that utilizes a coarse-to-fine analysis of the localized characteristics in pathology images. An initial surveying stage analyzes the diversity of coarse regions in the whole slide image. This includes extraction of spatially localized features of shape, color and texture from tiled regions covering the slide. Dimensionality reduction of the features assesses the image diversity in the tiled regions and clustering creates representative groups. A second stage provides a detailed analysis of a single representative tile from each group. An Elastic Net classifier produces a diagnostic decision value for each representative tile. A weighted voting scheme aggregates the decision values from these tiles to obtain a diagnosis at the whole slide level. We evaluated our method by automatically classifying 302 brain cancer cases into two possible diagnoses (glioblastoma multiforme (N = 182) versus lower grade glioma (N = 120)) with an accuracy of 93.1% (p < 0.001). We also evaluated our method in the dataset provided for the 2014 MICCAI Pathology Classification Challenge, in which our method, trained and tested using 5-fold cross validation, produced a classification accuracy of 100% (p < 0.001). Our method showed high stability and robustness to parameter variation, with accuracy varying between 95.5% and 100% when evaluated for a wide range of parameters. Our approach may be useful to automatically differentiate between the two cancer subtypes. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Shih, Ju-Ling; Ku, David Tawei; Hung, Su-Huan
2013-01-01
We investigate how the computerized dynamic assessment system improves the learning achievements of vocational high school students studying accounting. Our experiment was conducted under the one-group pretest-posttest design of 34 junior students. The questionnaire results were analyzed to determine student-learning attitudes and reactions toward…
ERIC Educational Resources Information Center
Easter, John; And Others
A description is provided of comprehensive Achievement Monitoring (CAM), a tool which enables classroom teachers to function as researchers and evaluators. Part I reviews the CAM philosophy and the section following discusses computerized feedback in CAM operations. The final two portions of the report describes the use of CAM in mathematics…
ERIC Educational Resources Information Center
Metz, Dale Evan; And Others
1992-01-01
A preliminary scheme for estimating the speech intelligibility of hearing-impaired speakers from acoustic parameters, using a computerized artificial neural network to process mathematically the acoustic input variables, is outlined. Tests with 60 hearing-impaired speakers found the scheme to be highly accurate in identifying speakers separated by…
Development of a Technical Data File On the Design and Use of Instructional Systems.
ERIC Educational Resources Information Center
Schumacher, Sanford P.
A technical data file concerned with the technology of Instructional System Development suitable for a variety of users was developed. The file was prepared in a way amenable to later computerized storage and retrieval. General information sources and indexes of highly probable relevance were reviewed with key words and relevant specialty journals…
NASA Astrophysics Data System (ADS)
Udupa, Jayaram K.; Odhner, Dewey; Falcao, Alexandre X.; Ciesielski, Krzysztof C.; Miranda, Paulo A. V.; Vaideeswaran, Pavithra; Mishra, Shipra; Grevera, George J.; Saboury, Babak; Torigian, Drew A.
2011-03-01
To make Quantitative Radiology (QR) a reality in routine clinical practice, computerized automatic anatomy recognition (AAR) becomes essential. As part of this larger goal, we present in this paper a novel fuzzy strategy for building bodywide group-wise anatomic models. They have the potential to handle uncertainties and variability in anatomy naturally and to be integrated with the fuzzy connectedness framework for image segmentation. Our approach is to build a family of models, called the Virtual Quantitative Human, representing normal adult subjects at a chosen resolution of the population variables (gender, age). Models are represented hierarchically, the descendents representing organs contained in parent organs. Based on an index of fuzziness of the models, 32 thorax data sets, and 10 organs defined in them, we found that the hierarchical approach to modeling can effectively handle the non-linear relationships in position, scale, and orientation that exist among organs in different patients.
The BIRN Project: Imaging the Nervous System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellisman, Mark
The grand goal in neuroscience research is to understand how the interplay of structural, chemical and electrical signals in nervous tissue gives rise to behavior. Experimental advances of the past decades have given the individual neuroscientist an increasingly powerful arsenal for obtaining data, from the level of molecules to nervous systems. Scientists have begun the arduous and challenging process of adapting and assembling neuroscience data at all scales of resolution and across disciplines into computerized databases and other easily accessed sources. These databases will complement the vast structural and sequence databases created to catalogue, organize and analyze gene sequences andmore » protein products. The general premise of the neuroscience goal is simple; namely that with "complete" knowledge of the genome and protein structures accruing rapidly we next need to assemble an infrastructure that will facilitate acquisition of an understanding for how functional complexes operate in their cell and tissue contexts.« less
The BIRN Project: Imaging the Nervous System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellisman, Mark
The grand goal in neuroscience research is to understand how the interplay of structural, chemical and electrical signals in nervous tissue gives rise to behavior. Experimental advances of the past decades have given the individual neuroscientist an increasingly powerful arsenal for obtaining data, from the level of molecules to nervous systems. Scientists have begun the arduous and challenging process of adapting and assembling neuroscience data at all scales of resolution and across disciplines into computerized databases and other easily accessed sources. These databases will complement the vast structural and sequence databases created to catalogue, organize and analyze gene sequences andmore » protein products. The general premise of the neuroscience goal is simple; namely that with 'complete' knowledge of the genome and protein structures accruing rapidly we next need to assemble an infrastructure that will facilitate acquisition of an understanding for how functional complexes operate in their cell and tissue contexts.« less
COMPUTERIZED SHAWNEE LIME/LIMESTONE SCRUBBING MODEL USERS MANUAL
The manual gives a general description of a computerized model for estimating design and cost of lime or limestone scrubber systems for flue gas desulfurization (FGD). It supplements PB80-123037 by extending the number of scrubber options which can be evaluated. It includes spray...
SHAWNEE LIME/LIMESTONE SCRUBBING COMPUTERIZED DESIGN/COST-ESTIMATE MODEL USERS MANUAL
The manual gives a general description of the Shawnee lime/limestone scrubbing computerized design/cost-estimate model and detailed procedures for using it. It describes all inputs and outputs, along with available options. The model, based on Shawnee Test Facility scrubbing data...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
Using Computerized Clinical Nursing Data Bases for Nursing Research.
ERIC Educational Resources Information Center
Nail, Lillian M.; Lange, Linda L.
1996-01-01
Addresses the recognition of differences between clinical and research data in using computerized clinical nursing databases and the issues of privacy and confidentiality for patients whose records are involved. Describes procedures for assessing the quality and usability of these data for nursing research. (SK)
40 CFR 51.358 - Test equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...
COMPUTERIZED FGD BYPRODUCT PRODUCTION AND MARKETING SYSTEM: USERS MANUAL
The users manual describes a computerized system--consisting of a number of integrated programs, models, and data bases--that has been developed to compare the costs of power plant strategies designed to meet clean air regulations. It describes the data bases, programs, and proce...
Procedures for Selecting Items for Computerized Adaptive Tests.
ERIC Educational Resources Information Center
Kingsbury, G. Gage; Zara, Anthony R.
1989-01-01
Several classical approaches and alternative approaches to item selection for computerized adaptive testing (CAT) are reviewed and compared. The study also describes procedures for constrained CAT that may be added to classical item selection approaches to allow them to be used for applied testing. (TJH)
COMP (Computerized Operational Materials Prescription).
ERIC Educational Resources Information Center
Rosenkranz, Catherine I.
Described is Project COMP (Computerized Operational Materials Prescription), an individualized reading instructional program for educable mentally retarded (EMR) children in regular or special classes. The program is designed to correlate with the Wisconsin Design for Reading (WDR) and to utilize a diagnostic teaching specialist who uses specific…
Termination Criteria for Computerized Classification Testing
ERIC Educational Resources Information Center
Thompson, Nathan A.
2011-01-01
Computerized classification testing (CCT) is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as "pass" and "fail." Like adaptive testing for point estimation of ability, the key component is the…
Total Library Computerization for Windows.
ERIC Educational Resources Information Center
Combs, Joseph, Jr.
1999-01-01
Presents a general review of features of version 2.1 of Total Library Computerization (TLC) for Windows from On Point, Inc. Includes information about pricing, hardware and operating systems, modules/functions available, user interface, security, on-line catalog functions, circulation, cataloging, and documentation and online help. A table…
36 CFR 1120.52 - Computerized records.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Computerized records. 1120.52 Section 1120.52 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE... additional programming of the computer, thus producing information not previously in being, is not required...
36 CFR 1120.52 - Computerized records.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Computerized records. 1120.52 Section 1120.52 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE... additional programming of the computer, thus producing information not previously in being, is not required...
ERIC Educational Resources Information Center
Balottin, Umberto; And Others
1989-01-01
The study of computerized tomography brain-scan findings with 45 autistic and 19 control subjects concluded that autism is nonspecifically associated with brain-scan abnormalities, and that other nonorganic, as well as organic, factors should be taken into account. (Author/DB)
Adaptive Computerized Instruction.
ERIC Educational Resources Information Center
Ray, Roger D.; And Others
1995-01-01
Describes an artificially intelligent multimedia computerized instruction system capable of developing a conceptual image of what a student is learning while the student is learning it. It focuses on principles of learning and adaptive behavioral control systems theory upon which the system is designed and demonstrates multiple user modes.…
40 CFR 51.358 - Test equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...
Computerized Financial Reporting Based on GAAP.
ERIC Educational Resources Information Center
Tikkanen, Stan; Liljeberg, Burt
1983-01-01
Describes the statewide computerized system developed in Minnesota following the 1976 enactment of the Uniform Financial Accounting and Reporting Standards (UFARS) law. UFARS includes provisions for an advisory council responsible for recommending accounting and reporting procedures, and seven data processing centers to serve all 560 Minnesota…
Rolfe, Mei Hsin Suzanne; Hamm, Jeff P; Waldie, Karen E
2008-03-01
Two versions of the line bisection task, paper-and-pencil and computerized, were administered to non-medicated children (5-12 years) with and without Attention-Deficit/Hyperactivity Disorder (ADHD). Fifteen children were classified with ADHD-Inattentive type (ADHD-I), 15 were classified with ADHD-Combined or Hyperactive-Impulsive type (ADHD-C), and 15 children served as controls. During the paper-and-pencil task, and irrespective of hand-use, participants with ADHD-C bisected lines with a right bias, whereas participants with ADHD-I showed a leftwards bias. Interestingly, during the computerized version, an opposite pattern of hemineglect was observed with a leftwards bias for participants with ADHD-C and a rightwards bias for participants with ADHD-I. These findings suggest that different task demands are associated with the paper-and-pencil and computerized tasks. The findings also suggest that the two subtypes differ according to their cognitive profile, and possibly differ as to their underlying neural impairment.
Tombaugh, Tom N; Rees, Laura; Stormer, Peter; Harrison, Allyson G; Smith, Andra
2007-01-01
In spite of the fact that reaction time (RT) measures are sensitive to the effects of traumatic brain injury (TBI), few RT procedures have been developed for use in standard clinical evaluations. The computerized test of information processing (CTIP) [Tombaugh, T. N., & Rees, L. (2000). Manual for the computerized tests of information processing (CTIP). Ottawa, Ont.: Carleton University] was designed to measure the degree to which TBI decreases the speed at which information is processed. The CTIP consists of three computerized programs that progressively increase the amount of information that is processed. Results of the current study demonstrated that RT increased as the difficulty of the CTIP tests increased (known as the complexity effect), and as severity of injury increased (from mild to severe TBI). The current study also demonstrated the importance of selecting a non-biased measure of variability. Overall, findings suggest that the CTIP is an easy to administer and sensitive measure of information processing speed.
An Analysis of Community Health Nurses Documentation: The Best Approach to Computerization
Chalmers, M.
1988-01-01
The study explored and analyzed the actual patient-related documentation performed by a sample of community health nurses working in voluntary home health agencies. The outcome of the study was a system flow chart of that documentation and included: common components of the documentation, where in the existing systems they are recorded, when they are recorded by the nurse and why they are used by the nurses and administrative personnel in the agencies. The flow chart is suitable for use as a prototype for the development of a computer software package for the computerization of the patient-related documentation by community health nurses. General System and communication theories were used as a framework for this study. A thorough analysis of the documenation resulted in a complete and exhaustive explication of the documentation by community health nurses, as well as the identification of what parts of that documentation lend themselves most readily to computerization and what areas, if any, may not readily adapt to computerization.
Bogdanova, Yelena; Yee, Megan K; Ho, Vivian T; Cicerone, Keith D
Comprehensive review of the use of computerized treatment as a rehabilitation tool for attention and executive function in adults (aged 18 years or older) who suffered an acquired brain injury. Systematic review of empirical research. Two reviewers independently assessed articles using the methodological quality criteria of Cicerone et al. Data extracted included sample size, diagnosis, intervention information, treatment schedule, assessment methods, and outcome measures. A literature review (PubMed, EMBASE, Ovid, Cochrane, PsychINFO, CINAHL) generated a total of 4931 publications. Twenty-eight studies using computerized cognitive interventions targeting attention and executive functions were included in this review. In 23 studies, significant improvements in attention and executive function subsequent to training were reported; in the remaining 5, promising trends were observed. Preliminary evidence suggests improvements in cognitive function following computerized rehabilitation for acquired brain injury populations including traumatic brain injury and stroke. Further studies are needed to address methodological issues (eg, small sample size, inadequate control groups) and to inform development of guidelines and standardized protocols.
Kosowicz, Maria; MacPherson, Sarah E
2017-01-01
Computerized cognitive assessment is becoming increasingly more common in clinical neuropsychological assessment and cognitive neuropsychological research. A number of computerized tasks now exist to assess multitasking abilities that are essential for everyday tasks such as cooking, shopping, or driving, but little is known about whether these tasks are appropriate for assessing older adults' multitasking. The present study directly compared age effects on multitasking when assessed using a computerized and a prop-based version of Craik and Bialystok's ( 2006 ) Breakfast task. Twenty participants aged 18 to 24 years and 20 participants aged 60 to 79 years were assessed on both versions of the Breakfast task. While age-related decrements in multitasking performance were found using the computerized task, significant age differences were not found on the majority of measures when the prop-based version was administered. The results suggest that age-related deficits in multitasking will be less when more contextualized, noncomputer based tasks are used.
Computerized tomography calibrator
NASA Technical Reports Server (NTRS)
Engel, Herbert P. (Inventor)
1991-01-01
A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.
Hazut, Koren; Romem, Pnina; Malkin, Smadar; Livshiz-Riven, Ilana
2016-12-01
The purpose of this study was to compare the predictive validity, economic efficiency, and faculty staff satisfaction of a computerized test versus a personal interview as admission methods for graduate nursing studies. A mixed method study was designed, including cross-sectional and retrospective cohorts, interviews, and cost analysis. One hundred and thirty-four students in the Master of Nursing program participated. The success of students in required core courses was similar in both admission method groups. The personal interview method was found to be a significant predictor of success, with cognitive variables the only significant contributors to the model. Higher satisfaction levels were reported with the computerized test compared with the personal interview method. The cost of the personal interview method, in annual hourly work, was 2.28 times higher than the computerized test. These findings may promote discussion regarding the cost benefit of the personal interview as an admission method for advanced academic studies in healthcare professions. © 2016 John Wiley & Sons Australia, Ltd.
Computerized N-acetylcysteine physician order entry by template protocol for acetaminophen toxicity.
Thompson, Trevonne M; Lu, Jenny J; Blackwood, Louisa; Leikin, Jerrold B
2011-01-01
Some medication dosing protocols are logistically complex for traditional physician ordering. The use of computerized physician order entry (CPOE) with templates, or order sets, may be useful to reduce medication administration errors. This study evaluated the rate of medication administration errors using CPOE order sets for N-acetylcysteine (NAC) use in treating acetaminophen poisoning. An 18-month retrospective review of computerized inpatient pharmacy records for NAC use was performed. All patients who received NAC for the treatment of acetaminophen poisoning were included. Each record was analyzed to determine the form of NAC given and whether an administration error occurred. In the 82 cases of acetaminophen poisoning in which NAC was given, no medication administration errors were identified. Oral NAC was given in 31 (38%) cases; intravenous NAC was given in 51 (62%) cases. In this retrospective analysis of N-acetylcysteine administration using computerized physician order entry and order sets, no medication administration errors occurred. CPOE is an effective tool in safely executing complicated protocols in an inpatient setting.
IGT-Open: An open-source, computerized version of the Iowa Gambling Task.
Dancy, Christopher L; Ritter, Frank E
2017-06-01
The Iowa Gambling Task (IGT) is commonly used to understand the processes involved in decision-making. Though the task was originally run without a computer, using a computerized version of the task has become typical. These computerized versions of the IGT are useful, because they can make the task more standardized across studies and allow for the task to be used in environments where a physical version of the task may be difficult or impossible to use (e.g., while collecting brain imaging data). Though these computerized versions of the IGT have been useful for experimentation, having multiple software implementations of the task could present reliability issues. We present an open-source software version of the Iowa Gambling Task (called IGT-Open) that allows for millisecond visual presentation accuracy and is freely available to be used and modified. This software has been used to collect data from human subjects and also has been used to run model-based simulations with computational process models developed to run in the ACT-R architecture.
Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh
2015-04-22
Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.
Computerized PET/CT image analysis in the evaluation of tumour response to therapy
Wang, J; Zhang, H H
2015-01-01
Current cancer therapy strategy is mostly population based, however, there are large differences in tumour response among patients. It is therefore important for treating physicians to know individual tumour response. In recent years, many studies proposed the use of computerized positron emission tomography/CT image analysis in the evaluation of tumour response. Results showed that computerized analysis overcame some major limitations of current qualitative and semiquantitative analysis and led to improved accuracy. In this review, we summarize these studies in four steps of the analysis: image registration, tumour segmentation, image feature extraction and response evaluation. Future works are proposed and challenges described. PMID:25723599
D'Orso, M I; Centemeri, R; Oggionni, P; Latocca, R; Crippa, M; Vercellino, R; Riva, M; Cesana, G
2011-01-01
The movement computerized analysis of upper limb is a valid support in the definition of residual functional capability and of specific work suitability in complex cases. This methodology of evaluation is able to correctly and objectively define the tridimensional ranges of motion of every patient's upper limb. This fact can be particularly useful for workers coming back to work after a work-related or a not work-related accident of for handicapped workers at the beginning of a new work activity. We report a research carried out using computerized analysis of motion of upper limbs in 20 engineering workers.
Tan, A C; Richards, R
1989-01-01
Three-dimensional (3D) medical graphics is becoming popular in clinical use on tomographic scanners. Research work in 3D reconstructive display of computerized tomography (CT) and magnetic resonance imaging (MRI) scans on conventional computers has produced many so-called pseudo-3D images. The quality of these images depends on the rendering algorithm, the coarseness of the digitized object, the number of grey levels and the image screen resolution. CT and MRI data are fundamentally voxel based and they produce images that are coarse because of the resolution of the data acquisition system. 3D images produced by the Z-buffer depth shading technique suffer loss of detail when complex objects with fine textural detail need to be displayed. Attempts have been made to improve the display of voxel objects, and existing techniques have shown the improvement possible using these post-processing algorithms. The improved rendering technique works on the Z-buffer image to generate a shaded image using a single light source in any direction. The effectiveness of the technique in generating a shaded image has been shown to be a useful means of presenting 3D information for clinical use.
MacMouse. Developing Preschool Readiness Concepts and Skills with HyperCard and MacRecorder.
ERIC Educational Resources Information Center
Fitterman, L. Jeffrey
Through developments with the use of the "Apple Macintosh" computer, "HyperCard," and "MacRecorder," children in preschool handicapped programs are now capable of participating in appropriate computerized learning experiences. "HyperCard" allows educators to produce their own computerized instructional…
Balancing Flexible Constraints and Measurement Precision in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Moyer, Eric L.; Galindo, Jennifer L.; Dodd, Barbara G.
2012-01-01
Managing test specifications--both multiple nonstatistical constraints and flexibly defined constraints--has become an important part of designing item selection procedures for computerized adaptive tests (CATs) in achievement testing. This study compared the effectiveness of three procedures: constrained CAT, flexible modified constrained CAT,…
Visualizing Syllables: Real-Time Computerized Feedback within a Speech-Language Intervention
ERIC Educational Resources Information Center
DeThorne, Laura; Aparicio Betancourt, Mariana; Karahalios, Karrie; Halle, Jim; Bogue, Ellen
2015-01-01
Computerized technologies now offer unprecedented opportunities to provide real-time visual feedback to facilitate children's speech-language development. We employed a mixed-method design to examine the effectiveness of two speech-language interventions aimed at facilitating children's multisyllabic productions: one incorporated a novel…
The Effects of Computerized Information Systems on Juvenile Courts
ERIC Educational Resources Information Center
Albrecht, Gary L.
1976-01-01
Organizational theorists alternatively hypothesized that computerized information systems (CIS) will produce no necessary changes, centralization, or decentralization in juvenile courts. This hypothesis is supported by the results of a four year study on the phenomenon. Suggestions are offered for improving the juvenile judicial system through…
Legal Issues for an Integrated Information Center.
ERIC Educational Resources Information Center
Rees, Warren; And Others
1991-01-01
The ability to collect, store, retrieve, and combine information in computerized databases has magnified the potential for misuse of information. Laws have begun to deal with these new threats by expanding rights of privacy, copyright, misrepresentation, products liability, and defamation. Laws regarding computerized databases are certain to…
Computerized Observation System (COS) for Field Experiences.
ERIC Educational Resources Information Center
Reed, Thomas M.; And Others
The Computerized Observation System (COS) is a software program which an observer can use with a portable microcomputer to document preservice and inservice teacher performance. Specific observable behavior such as appropriate questions and responses shown to increase student achievement are recorded as Low Inference Observation Measures. Time on…
Ethics and the Computerization of Pharmacy.
ERIC Educational Resources Information Center
McCarthy, Robert L.; Perrolle, Judith A.
1991-01-01
The current and potential impact of computerization on pharmacy practice is discussed, focusing on ethical dilemmas in the pharmacist-patient relationship, confidentiality of records, and the role of artificial intelligence in decision making about drug therapy. Case studies for use by teachers of pharmaceutical ethics are provided. (Author/MSE)
The Computerized "Assistant Prof."
ERIC Educational Resources Information Center
Shough, J. Stuart
The computerized "Assistant Prof" program at the University of South Carolina at Spartanburg is written in Lotus 1-2-3 to aid college professors in all their various administrative duties. The program performs four distinctive functions: (1) record keeping; (2) form producing; (3) grade calculating; and (4) feedback of student class…
Principles of Radio: A Laboratory Experiment
ERIC Educational Resources Information Center
Kraftmakher, Yaakov
2002-01-01
An experiment is proposed for learning the principles of radio. A simple radio receiver illustrates amplitude modulation and demodulation, the selectivity of a receiver and the features of a directional antenna. Both normal and computerized versions of the experiment are described. The computerized experiment employs the "ScienceWorkshop"…
The Computerization of the National Library in Paris.
ERIC Educational Resources Information Center
Lerin, Christian; Bernard, Annick
1986-01-01
Describes the organization and automation plan of the Bibliotheque Nationale (Paris, France) that was begun in 1981. Highlights include the method of moving toward computerization; technical choices; the choosing procedure (pre-qualification, bench-mark test); short term and pilot operations; and preparation for the implementation of the…
36 CFR 1120.52 - Computerized records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... organizations and upon the particular types of computer and associated equipment and the amounts of time on such... from the computer which permits copying the printout, the material will be made available at the per... information from computerized records frequently involves a minimum computer time cost of approximately $100...
36 CFR 1120.52 - Computerized records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... organizations and upon the particular types of computer and associated equipment and the amounts of time on such... from the computer which permits copying the printout, the material will be made available at the per... information from computerized records frequently involves a minimum computer time cost of approximately $100...