Sample records for high resolution display

  1. Flexible high-resolution display systems for the next generation of radiology reading rooms

    NASA Astrophysics Data System (ADS)

    Caban, Jesus J.; Wood, Bradford J.; Park, Adrian

    2007-03-01

    A flexible, scalable, high-resolution display system is presented to support the next generation of radiology reading rooms or interventional radiology suites. The project aims to create an environment for radiologists that will simultaneously facilitate image interpretation, analysis, and understanding while lowering visual and cognitive stress. Displays currently in use present radiologists with technical challenges to exploring complex datasets that we seek to address. These include resolution and brightness, display and ambient lighting differences, and degrees of complexity in addition to side-by-side comparison of time-variant and 2D/3D images. We address these issues through a scalable projector-based system that uses our custom-designed geometrical and photometrical calibration process to create a seamless, bright, high-resolution display environment that can reduce the visual fatigue commonly experienced by radiologists. The system we have designed uses an array of casually aligned projectors to cooperatively increase overall resolution and brightness. Images from a set of projectors in their narrowest zoom are combined at a shared projection surface, thus increasing the global "pixels per inch" (PPI) of the display environment. Two primary challenges - geometric calibration and photometric calibration - remained to be resolved before our high-resolution display system could be used in a radiology reading room or procedure suite. In this paper we present a method that accomplishes those calibrations and creates a flexible high-resolution display environment that appears seamless, sharp, and uniform across different devices.

  2. Microlaser-based displays

    NASA Astrophysics Data System (ADS)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  3. Fractional screen video enhancement apparatus

    DOEpatents

    Spletzer, Barry L [Albuquerque, NM; Davidson, George S [Albuquerque, NM; Zimmerer, Daniel J [Tijeras, NM; Marron, Lisa C [Albuquerque, NM

    2005-07-19

    The present invention provides a method and apparatus for displaying two portions of an image at two resolutions. For example, the invention can display an entire image at a first resolution, and a subset of the image at a second, higher resolution. Two inexpensive, low resolution displays can be used to produce a large image with high resolution only where needed.

  4. Using high-resolution displays for high-resolution cardiac data.

    PubMed

    Goodyer, Christopher; Hodrien, John; Wood, Jason; Kohl, Peter; Brodlie, Ken

    2009-07-13

    The ability to perform fast, accurate, high-resolution visualization is fundamental to improving our understanding of anatomical data. As the volumes of data increase from improvements in scanning technology, the methods applied to visualization must evolve. In this paper, we address the interactive display of data from high-resolution magnetic resonance imaging scanning of a rabbit heart and subsequent histological imaging. We describe a visualization environment involving a tiled liquid crystal display panel display wall and associated software, which provides an interactive and intuitive user interface. The oView software is an OpenGL application that is written for the VR Juggler environment. This environment abstracts displays and devices away from the application itself, aiding portability between different systems, from desktop PCs to multi-tiled display walls. Portability between display walls has been demonstrated through its use on walls at the universities of both Leeds and Oxford. We discuss important factors to be considered for interactive two-dimensional display of large three-dimensional datasets, including the use of intuitive input devices and level of detail aspects.

  5. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    NASA Astrophysics Data System (ADS)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  6. Display challenges resulting from the use of wide field of view imaging devices

    NASA Astrophysics Data System (ADS)

    Petty, Gregory J.; Fulton, Jack; Nicholson, Gail; Seals, Ean

    2012-06-01

    As focal plane array technologies advance and imagers increase in resolution, display technology must outpace the imaging improvements in order to adequately represent the complete data collection. Typical display devices tend to have an aspect ratio similar to 4:3 or 16:9, however a breed of Wide Field of View (WFOV) imaging devices exist that skew from the norm with aspect ratios as high as 5:1. This particular quality, when coupled with a high spatial resolution, presents a unique challenge for display devices. Standard display devices must choose between resizing the image data to fit the display and displaying the image data in native resolution and truncating potentially important information. The problem compounds when considering the applications; WFOV high-situationalawareness imagers are sought for space-limited military vehicles. Tradeoffs between these issues are assessed to the image quality of the WFOV sensor.

  7. 72-directional display having VGA resolution for high-appearance image generation

    NASA Astrophysics Data System (ADS)

    Takaki, Yasuhiro; Dairiki, Takeshi

    2006-02-01

    The high-density directional display, which was originally developed in order to realize a natural 3D display, is not only a 3D display but also a high-appearance display. The appearances of objects, such as glare and transparency, are the results of the reflection and the refraction of rays. The faithful reproduction of such appearances of objects is impossible using conventional 2D displays because rays diffuse on the display screen. The high-density directional display precisely controls the horizontal ray directions so that it can reproduce the appearances of objects. The fidelity of the reproduction of object appearances depends on the ray angle sampling pitch. The angle sampling pitch is determined by considering the human eye imaging system. In the present study the high-appearance display which has the resolution of 640×400 and emits rays in 72 different horizontal directions with the angle pitch of 0.38° was constructed. Two 72-directional displays were combined, each of which consisted of a high-resolution LCD panel (3,840×2,400) and a slanted lenticular sheet. Two images produced by two displays were superimposed by a half mirror. A slit array was placed at the focal plane of the lenticular sheet for each display to reduce the horizontal image crosstalk in the combined image. The impression analysis shows that the high-appearance display provides higher appearances and presence than the conventional 2D displays do.

  8. Large High Resolution Displays for Co-Located Collaborative Sensemaking: Display Usage and Territoriality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradel, Lauren; Endert, Alexander; Koch, Kristen

    2013-08-01

    Large, high-resolution vertical displays carry the potential to increase the accuracy of collaborative sensemaking, given correctly designed visual analytics tools. From an exploratory user study using a fictional textual intelligence analysis task, we investigated how users interact with the display to construct spatial schemas and externalize information, as well as how they establish shared and private territories. We investigated the space management strategies of users partitioned by type of tool philosophy followed (visualization- or text-centric). We classified the types of territorial behavior exhibited in terms of how the users interacted with information on the display (integrated or independent workspaces). Next,more » we examined how territorial behavior impacted the common ground between the pairs of users. Finally, we offer design suggestions for building future co-located collaborative visual analytics tools specifically for use on large, high-resolution vertical displays.« less

  9. Re-engineering the stereoscope for the 21st Century

    NASA Astrophysics Data System (ADS)

    Kollin, Joel S.; Hollander, Ari J.

    2007-02-01

    While discussing the current state of stereo head-mounted and 3D projection displays, the authors came to the realization that flat-panel LCD displays offer higher resolution than projection for stereo display at a low (and continually dropping) cost. More specifically, where head-mounted displays of moderate resolution and field-of-view cost tens of thousands of dollars, we can achieve an angular resolution approaching that of the human eye with a field-of-view (FOV) greater than 90° for less than $1500. For many immersive applications head tracking is unnecessary and sometimes even undesirable, and a low cost/high quality wide FOV display may significantly increase the application space for 3D display. After outlining the problem and potential of this solution we describe the initial construction of a simple Wheatstone stereoscope using 24" LCD displays and then show engineering improvements that increase the FOV and usability of the system. The applicability of a high-immersion, high-resolution display for art, entertainment, and simulation is presented along with a content production system that utilizes the capabilities of the system. We then discuss the potential use of the system for VR pain control therapy, treatment of post-traumatic stress disorders and other serious games applications.

  10. Exploratory visualization of astronomical data on ultra-high-resolution wall displays

    NASA Astrophysics Data System (ADS)

    Pietriga, Emmanuel; del Campo, Fernando; Ibsen, Amanda; Primet, Romain; Appert, Caroline; Chapuis, Olivier; Hempel, Maren; Muñoz, Roberto; Eyheramendy, Susana; Jordan, Andres; Dole, Hervé

    2016-07-01

    Ultra-high-resolution wall displays feature a very high pixel density over a large physical surface, which makes them well-suited to the collaborative, exploratory visualization of large datasets. We introduce FITS-OW, an application designed for such wall displays, that enables astronomers to navigate in large collections of FITS images, query astronomical databases, and display detailed, complementary data and documents about multiple sources simultaneously. We describe how astronomers interact with their data using both the wall's touchsensitive surface and handheld devices. We also report on the technical challenges we addressed in terms of distributed graphics rendering and data sharing over the computer clusters that drive wall displays.

  11. The Eyephone: a head-mounted stereo display

    NASA Astrophysics Data System (ADS)

    Teitel, Michael A.

    1990-09-01

    Head mounted stereo displays for virtual environments and computer simulations have been made since 1969. Most of the recent displays have been based on monochrome (black and white) liquid crystal display technology. Color LCD displays have generally not been used due to their lower resolution and color triad structure. As the resolution of color LCDdisplays is increasing we have begun to use color displays in our Eyephone. In this paper we describe four methods for minimizing the effect of the color triads in the magnified images of LCD displays in the Eyephone stereo head mounted display. We have settled on the use of wavefront randomizer with a spatial frequency enhancement overlay in order to blur the triacis in the displays while keeping the perceived resolution of the display high.

  12. Space to Think: Large, High-Resolution Displays for Sensemaking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, Christopher P.; Endert, Alexander; North, Chris

    2010-05-05

    Space supports human cognitive abilities in a myriad of ways. The note attached to the side of the monitor, the papers spread out on the desk, diagrams scrawled on a whiteboard, and even the keys left out on the counter are all examples of using space to recall, reveal relationships, and think. Technological advances have made it possible to construct large display environments in which space has real meaning. This paper examines how increased space affects the way displays are regarded and used within the context of the cognitively demanding task of sensemaking. A study was conducted observing analysts usingmore » a prototype large, high-resolution display to solve an analytic problem. This paper reports on the results of this study and suggests a number of potential design criteria for future sensemaking tools developed for large, high-resolution displays.« less

  13. Bifocal computational near eye light field displays and Structure parameters determination scheme for bifocal computational display.

    PubMed

    Liu, Mali; Lu, Chihao; Li, Haifeng; Liu, Xu

    2018-02-19

    We propose a bifocal computational near eye light field display (bifocal computational display) and structure parameters determination scheme (SPDS) for bifocal computational display that achieves greater depth of field (DOF), high resolution, accommodation and compact form factor. Using a liquid varifocal lens, two single-focal computational light fields are superimposed to reconstruct a virtual object's light field by time multiplex and avoid the limitation on high refresh rate. By minimizing the deviation between reconstructed light field and original light field, we propose a determination framework to determine the structure parameters of bifocal computational light field display. When applied to different objective to SPDS, it can achieve high average resolution or uniform resolution display over scene depth range. To analyze the advantages and limitation of our proposed method, we have conducted simulations and constructed a simple prototype which comprises a liquid varifocal lens, dual-layer LCDs and a uniform backlight. The results of simulation and experiments with our method show that the proposed system can achieve expected performance well. Owing to the excellent performance of our system, we motivate bifocal computational display and SPDS to contribute to a daily-use and commercial virtual reality display.

  14. Recent advances in flexible low power cholesteric LCDs

    NASA Astrophysics Data System (ADS)

    Khan, Asad; Shiyanovskaya, Irina; Montbach, Erica; Schneider, Tod; Nicholson, Forrest; Miller, Nick; Marhefka, Duane; Ernst, Todd; Doane, J. W.

    2006-05-01

    Bistable reflective cholesteric displays are a liquid crystal display technology developed to fill a market need for very low power displays. Their unique look, high reflectivity, bistability, and simple structure make them an ideal flat panel display choice for handheld or other portable devices where small lightweight batteries with long lifetimes are important. Applications ranging from low resolution large signs to ultra high resolution electronic books can utilize cholesteric displays to not only benefit from the numerous features, but also create enabling features that other flat panel display technologies cannot. Flexible displays are the focus of attention of numerous research groups and corporations worldwide. Cholesteric displays have been demonstrated to be highly amenable to flexible substrates. This paper will review recent advances in flexible cholesteric displays including both phase separation and emulsification approaches to encapsulation. Both approaches provide unique benefits to various aspects of manufacturability, processes, flexibility, and conformability.

  15. High-resolution AM LCD development for avionic applications

    NASA Astrophysics Data System (ADS)

    Lamberth, Larry S.; Laddu, Ravindra R.; Harris, Doug; Sarma, Kalluri R.; Li, Wang-Yang; Chien, C. C.; Chu, C. Y.; Lee, C. S.; Kuo, Chen-Lung

    2003-09-01

    For the first time, an avionic grade MVA AM LCD with wide viewing angle has been developed for use in either landscape or portrait mode. The development of a high resolution Multi-domain Vertical Alignment (MVA) Active Matrix Liquid Crystal Display (AM LCD) is described. Challenges met in this development include achieving the required performance with high luminance and sunlight readability while meeting stringent optical (image quality) and environmental performance requirements of avionics displays. In this paper the optical and environmental performance of this high resolution 14.1" MVA-AM-LCD are discussed and some performance comparisons to conventional AM-LCDs are documented. This AM LCD has found multiple Business Aviation and Military display applications and cockpit pictures are presented.

  16. High Resolution Displays In The Apple Macintosh And IBM PC Environments

    NASA Astrophysics Data System (ADS)

    Winegarden, Steven

    1989-07-01

    High resolution displays are one of the key elements that distinguish user oriented document finishing or publishing stations. A number of factors have been involved in bringing these to the desktop environment. At Sigma Designs we have concentrated on enhancing the capabilites of IBM PCs and compatibles and Apple Macintosh computer systems.

  17. A Survey of Large High-Resolution Display Technologies, Techniques, and Applications

    DTIC Science & Technology

    2006-03-01

    developing immersive applications with their large-display environments over the last several years [128]. They have projects for virtual prototyping...feedback concerning common usage of how users do and do not use a large high-resolution display to perform ordinary tasks, such as reading papers , surfing...tremendously in the past decade, and we believe it is far from running out of steam. We feel it also will evolve into an interdisciplinary research area

  18. Interactive Display of High-Resolution Images on the World Wide Web.

    ERIC Educational Resources Information Center

    Clyde, Stephen W.; Hirschi, Gregory W.

    Viewing high-resolution images on the World Wide Web at a level of detail necessary for collaborative research is still a problem today, given the Internet's current bandwidth limitations and its ever increasing network traffic. ImageEyes is an interactive display tool being developed at Utah State University that addresses this problem by…

  19. An Electronic Pressure Profile Display system for aeronautic test facilities

    NASA Technical Reports Server (NTRS)

    Woike, Mark R.

    1990-01-01

    The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPI) unit which interfaces with a host computer. The host computer collects the pressure data from the DPI unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.

  20. An electronic pressure profile display system for aeronautic test facilities

    NASA Technical Reports Server (NTRS)

    Woike, Mark R.

    1990-01-01

    The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPT) unit which interfaces with a host computer. The host computer collects the pressure data from the DPT unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.

  1. State-of-the-art for large area high resolution gray scale and full color AC plasma flat panel displays

    NASA Technical Reports Server (NTRS)

    Stoller, Ray A.; Wedding, Donald K.; Friedman, Peter S.

    1993-01-01

    A development status evaluation is presented for gas plasma display technology, noting how tradeoffs among the parameters of size, resolution, speed, portability, color, and image quality can yield cost-effective solutions for medical imaging, CAD, teleconferencing, multimedia, and both civil and military applications. Attention is given to plasma-based large-area displays' suitability for radar, sonar, and IR, due to their lack of EM susceptibility. Both monochrome and color displays are available.

  2. A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen

    NASA Astrophysics Data System (ADS)

    Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu

    2018-02-01

    Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.

  3. Implementation of a high-resolution workstation for primary diagnosis of projection radiography images

    NASA Astrophysics Data System (ADS)

    Good, Walter F.; Herron, John M.; Maitz, Glenn S.; Gur, David; Miller, Stephen L.; Straub, William H.; Fuhrman, Carl R.

    1990-08-01

    We designed and implemented a high-resolution video workstation as the central hardware component in a comprehensive multi-project program comparing the use of digital and film modalities. The workstation utilizes a 1.8 GByte real-time disk (RCI) capable of storing 400 full-resolution images and two Tektronix (GMA251) display controllers with 19" monitors (GMA2O2). The display is configured in a portrait format with a resolution of 1536 x 2048 x 8 bit, and operates at 75 Hz in a noninterlaced mode. Transmission of data through a 12 to 8 bit lookup table into the display controllers occurs at 20 MBytes/second (.35 seconds per image). The workstation allows easy use of brightness (level) and contrast (window) to be manipulated with a trackball, and various processing options can be selected using push buttons. Display of any of the 400 images is also performed at 20MBytes/sec (.35 sec/image). A separate text display provides for the automatic display of patient history data and for a scoring form through which readers can interact with the system by means of a computer mouse. In addition, the workstation provides for the randomization of cases and for the immediate entry of diagnostic responses into a master database. Over the past year this workstation has been used for over 10,000 readings in diagnostic studies related to 1) image resolution; 2) film vs. soft display; 3) incorporation of patient history data into the reading process; and 4) usefulness of image processing.

  4. A 2D/3D hybrid integral imaging display by using fast switchable hexagonal liquid crystal lens array

    NASA Astrophysics Data System (ADS)

    Lee, Hsin-Hsueh; Huang, Ping-Ju; Wu, Jui-Yi; Hsieh, Po-Yuan; Huang, Yi-Pai

    2017-05-01

    The paper proposes a new display which could switch 2D and 3D images on a monitor, and we call it as Hybrid Display. In 3D display technologies, the reduction of image resolution is still an important issue. The more angle information offer to the observer, the less spatial resolution would offer to image resolution because of the fixed panel resolution. Take it for example, in the integral photography system, the part of image without depth, like background, will reduce its resolution by transform from 2D to 3D image. Therefore, we proposed a method by using liquid crystal component to quickly switch the 2D image and 3D image. Meanwhile, the 2D image is set as a background to compensate the resolution.. In the experiment, hexagonal liquid crystal lens array would be used to take the place of fixed lens array. Moreover, in order to increase lens power of the hexagonal LC lens array, we applied high resistance (Hi-R) layer structure on the electrode. Hi-R layer would make the gradient electric field and affect the lens profile. Also, we use panel with 801 PPI to display the integral image in our system. Hence, the consequence of full resolution 2D background with the 3D depth object forms the Hybrid Display.

  5. Displaying Geographically-Based Domestic Statistics

    NASA Technical Reports Server (NTRS)

    Quann, J.; Dalton, J.; Banks, M.; Helfer, D.; Szczur, M.; Winkert, G.; Billingsley, J.; Borgstede, R.; Chen, J.; Chen, L.; hide

    1982-01-01

    Decision Information Display System (DIDS) is rapid-response information-retrieval and color-graphics display system. DIDS transforms tables of geographically-based domestic statistics (such as population or unemployment by county, energy usage by county, or air-quality figures) into high-resolution, color-coded maps on television display screen.

  6. Synthetic Melanin E-Ink.

    PubMed

    Chang, Lingqian; Chen, Feng; Zhang, Xiaokang; Kuang, Tairong; Li, Mi; Hu, Jiaming; Shi, Junfeng; Lee, Ly James; Cheng, Huanyu; Li, Yiwen

    2017-05-17

    Extensive efforts have been devoted to the development of surfactant-free electronic ink (E-ink) with excellent display resolution for high-definition resolution display. Herein, we report the use of polydopamine-based synthetic melanin, a class of functional nanoparticles with similar chemical compositions and physical properties to those of naturally occurring melanin, as a new E-ink material. It was found that such E-ink displays could achieve ultrahigh resolution (>10 000 ppi) and low power consumption (operation voltage of only 1 V) in aqueous solutions. Interestingly, simple oxidation of synthetic melanin nanoparticles enables the generation of intrinsic fluorescence, allowing further development of fluorescent E-ink displays with nanoscale resolution. We describe these bioinspired materials in an initial proof-of-concept study and propose that synthetic melanin nanoparticles will be suitable for electronic nanoinks with a potential wide range of applications in molecular patterning and fluorescence bioimaging.

  7. Enabling high grayscale resolution displays and accurate response time measurements on conventional computers.

    PubMed

    Li, Xiangrui; Lu, Zhong-Lin

    2012-02-29

    Display systems based on conventional computer graphics cards are capable of generating images with 8-bit gray level resolution. However, most experiments in vision research require displays with more than 12 bits of luminance resolution. Several solutions are available. Bit++ (1) and DataPixx (2) use the Digital Visual Interface (DVI) output from graphics cards and high resolution (14 or 16-bit) digital-to-analog converters to drive analog display devices. The VideoSwitcher (3) described here combines analog video signals from the red and blue channels of graphics cards with different weights using a passive resister network (4) and an active circuit to deliver identical video signals to the three channels of color monitors. The method provides an inexpensive way to enable high-resolution monochromatic displays using conventional graphics cards and analog monitors. It can also provide trigger signals that can be used to mark stimulus onsets, making it easy to synchronize visual displays with physiological recordings or response time measurements. Although computer keyboards and mice are frequently used in measuring response times (RT), the accuracy of these measurements is quite low. The RTbox is a specialized hardware and software solution for accurate RT measurements. Connected to the host computer through a USB connection, the driver of the RTbox is compatible with all conventional operating systems. It uses a microprocessor and high-resolution clock to record the identities and timing of button events, which are buffered until the host computer retrieves them. The recorded button events are not affected by potential timing uncertainties or biases associated with data transmission and processing in the host computer. The asynchronous storage greatly simplifies the design of user programs. Several methods are available to synchronize the clocks of the RTbox and the host computer. The RTbox can also receive external triggers and be used to measure RT with respect to external events. Both VideoSwitcher and RTbox are available for users to purchase. The relevant information and many demonstration programs can be found at http://lobes.usc.edu/.

  8. Toshiba TDF-500 High Resolution Viewing And Analysis System

    NASA Astrophysics Data System (ADS)

    Roberts, Barry; Kakegawa, M.; Nishikawa, M.; Oikawa, D.

    1988-06-01

    A high resolution, operator interactive, medical viewing and analysis system has been developed by Toshiba and Bio-Imaging Research. This system provides many advanced features including high resolution displays, a very large image memory and advanced image processing capability. In particular, the system provides CRT frame buffers capable of update in one frame period, an array processor capable of image processing at operator interactive speeds, and a memory system capable of updating multiple frame buffers at frame rates whilst supporting multiple array processors. The display system provides 1024 x 1536 display resolution at 40Hz frame and 80Hz field rates. In particular, the ability to provide whole or partial update of the screen at the scanning rate is a key feature. This allows multiple viewports or windows in the display buffer with both fixed and cine capability. To support image processing features such as windowing, pan, zoom, minification, filtering, ROI analysis, multiplanar and 3D reconstruction, a high performance CPU is integrated into the system. This CPU is an array processor capable of up to 400 million instructions per second. To support the multiple viewer and array processors' instantaneous high memory bandwidth requirement, an ultra fast memory system is used. This memory system has a bandwidth capability of 400MB/sec and a total capacity of 256MB. This bandwidth is more than adequate to support several high resolution CRT's and also the fast processing unit. This fully integrated approach allows effective real time image processing. The integrated design of viewing system, memory system and array processor are key to the imaging system. It is the intention to describe the architecture of the image system in this paper.

  9. Demonstration of a large-size horizontal light-field display based on the LED panel and the micro-pinhole unit array

    NASA Astrophysics Data System (ADS)

    Yang, Le; Sang, Xinzhu; Yu, Xunbo; Liu, Boyang; Liu, Li; Yang, Shenwu; Yan, Binbin; Du, Jingyan; Gao, Chao

    2018-05-01

    A 54-inch horizontal-parallax only light-field display based on the light-emitting diode (LED) panel and the micro-pinhole unit array (MPUA) is demonstrated. Normally, the perceived 3D effect of the three-dimensional (3D) display with smooth motion parallax and abundant light-field information can be enhanced with increasing the density of viewpoints. However, the density of viewpoints is inversely proportional to the spatial display resolution for the conventional integral imaging. Here, a special MPUA is designed and fabricated, and the displayed 3D scene constructed by the proposed horizontal light-field display is presented. Compared with the conventional integral imaging, both the density of horizontal viewpoints and the spatial display resolution are significantly improved. In the experiment, A 54-inch horizontal light-field display with 42.8° viewing angle based on the LED panel with the resolution of 1280 × 720 and the MPUA is realized, which can provide natural 3D visual effect to observers with high quality.

  10. Scalable Adaptive Graphics Environment (SAGE) Software for the Visualization of Large Data Sets on a Video Wall

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary; Srikishen, Jayanthi; Edwards, Rita; Cross, David; Welch, Jon; Smith, Matt

    2013-01-01

    The use of collaborative scientific visualization systems for the analysis, visualization, and sharing of "big data" available from new high resolution remote sensing satellite sensors or four-dimensional numerical model simulations is propelling the wider adoption of ultra-resolution tiled display walls interconnected by high speed networks. These systems require a globally connected and well-integrated operating environment that provides persistent visualization and collaboration services. This abstract and subsequent presentation describes a new collaborative visualization system installed for NASA's Shortterm Prediction Research and Transition (SPoRT) program at Marshall Space Flight Center and its use for Earth science applications. The system consists of a 3 x 4 array of 1920 x 1080 pixel thin bezel video monitors mounted on a wall in a scientific collaboration lab. The monitors are physically and virtually integrated into a 14' x 7' for video display. The display of scientific data on the video wall is controlled by a single Alienware Aurora PC with a 2nd Generation Intel Core 4.1 GHz processor, 32 GB memory, and an AMD Fire Pro W600 video card with 6 mini display port connections. Six mini display-to-dual DVI cables are used to connect the 12 individual video monitors. The open source Scalable Adaptive Graphics Environment (SAGE) windowing and media control framework, running on top of the Ubuntu 12 Linux operating system, allows several users to simultaneously control the display and storage of high resolution still and moving graphics in a variety of formats, on tiled display walls of any size. The Ubuntu operating system supports the open source Scalable Adaptive Graphics Environment (SAGE) software which provides a common environment, or framework, enabling its users to access, display and share a variety of data-intensive information. This information can be digital-cinema animations, high-resolution images, high-definition video-teleconferences, presentation slides, documents, spreadsheets or laptop screens. SAGE is cross-platform, community-driven, open-source visualization and collaboration middleware that utilizes shared national and international cyberinfrastructure for the advancement of scientific research and education.

  11. Scalable Adaptive Graphics Environment (SAGE) Software for the Visualization of Large Data Sets on a Video Wall

    NASA Astrophysics Data System (ADS)

    Jedlovec, G.; Srikishen, J.; Edwards, R.; Cross, D.; Welch, J. D.; Smith, M. R.

    2013-12-01

    The use of collaborative scientific visualization systems for the analysis, visualization, and sharing of 'big data' available from new high resolution remote sensing satellite sensors or four-dimensional numerical model simulations is propelling the wider adoption of ultra-resolution tiled display walls interconnected by high speed networks. These systems require a globally connected and well-integrated operating environment that provides persistent visualization and collaboration services. This abstract and subsequent presentation describes a new collaborative visualization system installed for NASA's Short-term Prediction Research and Transition (SPoRT) program at Marshall Space Flight Center and its use for Earth science applications. The system consists of a 3 x 4 array of 1920 x 1080 pixel thin bezel video monitors mounted on a wall in a scientific collaboration lab. The monitors are physically and virtually integrated into a 14' x 7' for video display. The display of scientific data on the video wall is controlled by a single Alienware Aurora PC with a 2nd Generation Intel Core 4.1 GHz processor, 32 GB memory, and an AMD Fire Pro W600 video card with 6 mini display port connections. Six mini display-to-dual DVI cables are used to connect the 12 individual video monitors. The open source Scalable Adaptive Graphics Environment (SAGE) windowing and media control framework, running on top of the Ubuntu 12 Linux operating system, allows several users to simultaneously control the display and storage of high resolution still and moving graphics in a variety of formats, on tiled display walls of any size. The Ubuntu operating system supports the open source Scalable Adaptive Graphics Environment (SAGE) software which provides a common environment, or framework, enabling its users to access, display and share a variety of data-intensive information. This information can be digital-cinema animations, high-resolution images, high-definition video-teleconferences, presentation slides, documents, spreadsheets or laptop screens. SAGE is cross-platform, community-driven, open-source visualization and collaboration middleware that utilizes shared national and international cyberinfrastructure for the advancement of scientific research and education.

  12. Visually Lossless JPEG 2000 for Remote Image Browsing

    PubMed Central

    Oh, Han; Bilgin, Ali; Marcellin, Michael

    2017-01-01

    Image sizes have increased exponentially in recent years. The resulting high-resolution images are often viewed via remote image browsing. Zooming and panning are desirable features in this context, which result in disparate spatial regions of an image being displayed at a variety of (spatial) resolutions. When an image is displayed at a reduced resolution, the quantization step sizes needed for visually lossless quality generally increase. This paper investigates the quantization step sizes needed for visually lossless display as a function of resolution, and proposes a method that effectively incorporates the resulting (multiple) quantization step sizes into a single JPEG2000 codestream. This codestream is JPEG2000 Part 1 compliant and allows for visually lossless decoding at all resolutions natively supported by the wavelet transform as well as arbitrary intermediate resolutions, using only a fraction of the full-resolution codestream. When images are browsed remotely using the JPEG2000 Interactive Protocol (JPIP), the required bandwidth is significantly reduced, as demonstrated by extensive experimental results. PMID:28748112

  13. Advanced aerosense display interfaces

    NASA Astrophysics Data System (ADS)

    Hopper, Darrel G.; Meyer, Frederick M.

    1998-09-01

    High-resolution display technologies are being developed to meet the ever-increasing demand for realistic detail. The requirement for evermore visual information exceeds the capacity of fielded aerospace display interfaces. In this paper we begin an exploration of display interfaces and evolving aerospace requirements. Current and evolving standards for avionics, commercial, and flat panel displays are summarized and compared to near term goals for military and aerospace applications. Aerospace and military applications prior to 2005 up to UXGA and digital HDTV resolution can be met by using commercial interface standard developments. Advanced aerospace requirements require yet higher resolutions (2560 X 2048 color pixels, 5120 X 4096 color pixels at 85 Hz, etc.) and necessitate the initiation of discussion herein of an 'ultra digital interface standard (UDIS)' which includes 'smart interface' features such as large memory and blazingly fast resizing microcomputer. Interface capacity, IT, increased about 105 from 1973 to 1998; 102 more is needed for UDIS.

  14. High-resolution, continuous field-of-view (FOV), non-rotating imaging system

    NASA Technical Reports Server (NTRS)

    Huntsberger, Terrance L. (Inventor); Stirbl, Robert C. (Inventor); Aghazarian, Hrand (Inventor); Padgett, Curtis W. (Inventor)

    2010-01-01

    A high resolution CMOS imaging system especially suitable for use in a periscope head. The imaging system includes a sensor head for scene acquisition, and a control apparatus inclusive of distributed processors and software for device-control, data handling, and display. The sensor head encloses a combination of wide field-of-view CMOS imagers and narrow field-of-view CMOS imagers. Each bank of imagers is controlled by a dedicated processing module in order to handle information flow and image analysis of the outputs of the camera system. The imaging system also includes automated or manually controlled display system and software for providing an interactive graphical user interface (GUI) that displays a full 360-degree field of view and allows the user or automated ATR system to select regions for higher resolution inspection.

  15. High-resolution imaging optomechatronics for precise liquid crystal display module bonding automated optical inspection

    NASA Astrophysics Data System (ADS)

    Ni, Guangming; Liu, Lin; Zhang, Jing; Liu, Juanxiu; Liu, Yong

    2018-01-01

    With the development of the liquid crystal display (LCD) module industry, LCD modules become more and more precise with larger sizes, which demands harsh imaging requirements for automated optical inspection (AOI). Here, we report a high-resolution and clearly focused imaging optomechatronics for precise LCD module bonding AOI inspection. It first presents and achieves high-resolution imaging for LCD module bonding AOI inspection using a line scan camera (LSC) triggered by a linear optical encoder, self-adaptive focusing for the whole large imaging region using LSC, and a laser displacement sensor, which reduces the requirements of machining, assembly, and motion control of AOI devices. Results show that this system can directly achieve clearly focused imaging for AOI inspection of large LCD module bonding with 0.8 μm image resolution, 2.65-mm scan imaging width, and no limited imaging width theoretically. All of these are significant for AOI inspection in the LCD module industry and other fields that require imaging large regions with high resolution.

  16. Development of an immersive virtual reality head-mounted display with high performance.

    PubMed

    Wang, Yunqi; Liu, Weiqi; Meng, Xiangxiang; Fu, Hanyi; Zhang, Daliang; Kang, Yusi; Feng, Rui; Wei, Zhonglun; Zhu, Xiuqing; Jiang, Guohua

    2016-09-01

    To resolve the contradiction between large field of view and high resolution in immersive virtual reality (VR) head-mounted displays (HMDs), an HMD monocular optical system with a large field of view and high resolution was designed. The system was fabricated by adopting aspheric technology with CNC grinding and a high-resolution LCD as the image source. With this monocular optical system, an HMD binocular optical system with a wide-range continuously adjustable interpupillary distance was achieved in the form of partially overlapping fields of view (FOV) combined with a screw adjustment mechanism. A fast image processor-centered LCD driver circuit and an image preprocessing system were also built to address binocular vision inconsistency in the partially overlapping FOV binocular optical system. The distortions of the HMD optical system with a large field of view were measured. Meanwhile, the optical distortions in the display and the trapezoidal distortions introduced during image processing were corrected by a calibration model for reverse rotations and translations. A high-performance not-fully-transparent VR HMD device with high resolution (1920×1080) and large FOV [141.6°(H)×73.08°(V)] was developed. The full field-of-view average value of angular resolution is 18.6  pixels/degree. With the device, high-quality VR simulations can be completed under various scenarios, and the device can be utilized for simulated trainings in aeronautics, astronautics, and other fields with corresponding platforms. The developed device has positive practical significance.

  17. A novel wide-field-of-view display method with higher central resolution for hyper-realistic head dome projector

    NASA Astrophysics Data System (ADS)

    Hotta, Aira; Sasaki, Takashi; Okumura, Haruhiko

    2007-02-01

    In this paper, we propose a novel display method to realize a high-resolution image in a central visual field for a hyper-realistic head dome projector. The method uses image processing based on the characteristics of human vision, namely, high central visual acuity and low peripheral visual acuity, and pixel shift technology, which is one of the resolution-enhancing technologies for projectors. The projected image with our method is a fine wide-viewing-angle image with high definition in the central visual field. We evaluated the psychological effects of the projected images with our method in terms of sensation of reality. According to the result, we obtained 1.5 times higher resolution in the central visual field and a greater sensation of reality by using our method.

  18. Impact of phosphor luminance noise on the specification of high-resolution CRT displays for medical imaging

    NASA Astrophysics Data System (ADS)

    Muka, Edward; Mertelmeier, Thomas; Slone, Richard M.; Senol, Evren

    1997-05-01

    We studied the impact of CRT spot size, phosphor luminance noise and image noise on the specification of high- resolution CRT displays that address the critical needs of general chest radiography. Using Argus CRT simulation software, the design of high-resolution CRTs for the display of adult chest radiographs was studied. The simulated images were printed on a laser printer and evaluated by a board- certified radiologist, RMS. The validity of the Argus simulation was assessed by modeling a 1k X 1k pixels CRT, whose technical parameters were sufficiently well known. Comments from the observer are presented comparing the simulated 2k display and a size-matched replicate of the original screen/film image. Critical parameters like phosphor luminance efficiency and its impact on electron beam size and phosphor luminance noise and its impact on radiographic image noise are discussed. We conclude that Argus CRT simulation software can successfully model the performance of CRTs intended to display medical images permitting consideration of critical parameters without costly manufacturing trials. Based on the 2k CRT simulation results, we suggest that a low luminance noise phosphor such as type p45 be used to ensure that specifying a small spot size would yield the anticipated sharpness improvements.

  19. High-performance large-area AMLCD avionic display module

    NASA Astrophysics Data System (ADS)

    Syroid, Daniel D.; Hansen, Glenn A.

    1995-06-01

    There is a need for a reliable source of high performance large area sunlight readable active matrix liquid crystal displays (AMLCDs) for avionic and military land vehicle applications. Image Quest has developed an avionic display module (ADM) to demonstrate the capability to produce high performance avionic displays to satisfy this need. The ADM is a large area (6.24 X 8.32 inch) display with VGA compatible interface, 640 X 480 color pixels and 64 gray shades per primary color. The display features excellent color discrimination in full sunlight due to a saturated color gamut, very low specular reflectance (< 1%) and high output white luminance (200 fL). The ADM is designed from the glass up to fully meet the avionic and military application and environment. Control over all the display performance parameters including contrast, transmission, chroma, resolution, active size and packaging configuration is ensured because Image Quest produces all of the critical elements of the display. These elements include the a-Si TFT AMLCD glass, RGB color filter matrix, bonding of folded back driver TABs, anti-reflective cover glass, LC heater and integration of high luminance hot cathode backlight with thermal controls. The display features rugged compact packaging, 2000:1 luminance dimming range and wide operating temperature range (-40 to +71 $DRGC). In the immediate future Image Quest plans to expand the development efforts to other similar custom high resolution and high performance avionic display module configurations including 4 X 4 inch delta triad, 6.7 X 6.7 inch delta triad and 16.5 inch diagonal with 1280 X 1024 pixels. Image Quest can deliver up to 10,000 displays per year on a timely basis at a reasonable cost.

  20. High Resolution Displays Using NCAP Liquid Crystals

    NASA Astrophysics Data System (ADS)

    Macknick, A. Brian; Jones, Phil; White, Larry

    1989-07-01

    Nematic curvilinear aligned phase (NCAP) liquid crystals have been found useful for high information content video displays. NCAP materials are liquid crystals which have been encapsulated in a polymer matrix and which have a light transmission which is variable with applied electric fields. Because NCAP materials do not require polarizers, their on-state transmission is substantially better than twisted nematic cells. All dimensional tolerances are locked in during the encapsulation process and hence there are no critical sealing or spacing issues. By controlling the polymer/liquid crystal morphology, switching speeds of NCAP materials have been significantly improved over twisted nematic systems. Recent work has combined active matrix addressing with NCAP materials. Active matrices, such as thin film transistors, have given displays of high resolution. The paper will discuss the advantages of NCAP materials specifically designed for operation at video rates on transistor arrays; applications for both backlit and projection displays will be discussed.

  1. Liquid crystal light valve technologies for display applications

    NASA Astrophysics Data System (ADS)

    Kikuchi, Hiroshi; Takizawa, Kuniharu

    2001-11-01

    The liquid crystal (LC) light valve, which is a spatial light modulator that uses LC material, is a very important device in the area of display development, image processing, optical computing, holograms, etc. In particular, there have been dramatic developments in the past few years in the application of the LC light valve to projectors and other display technologies. Various LC operating modes have been developed, including thin film transistors, MOS-FETs and other active matrix drive techniques to meet the requirements for higher resolution, and substantial improvements have been achieved in the performance of optical systems, resulting in brighter display images. Given this background, the number of applications for the LC light valve has greatly increased. The resolution has increased from QVGA (320 x 240) to QXGA (2048 x 1536) or even super- high resolution of eight million pixels. In the area of optical output, projectors of 600 to 13,000 lm are now available, and they are used for presentations, home theatres, electronic cinema and other diverse applications. Projectors using the LC light valve can display high- resolution images on large screens. They are now expected to be developed further as part of hyper-reality visual systems. This paper provides an overview of the needs for large-screen displays, human factors related to visual effects, the way in which LC light valves are applied to projectors, improvements in moving picture quality, and the results of the latest studies that have been made to increase the quality of images and moving images or pictures.

  2. A multiresolution halftoning algorithm for progressive display

    NASA Astrophysics Data System (ADS)

    Mukherjee, Mithun; Sharma, Gaurav

    2005-01-01

    We describe and implement an algorithmic framework for memory efficient, 'on-the-fly' halftoning in a progressive transmission environment. Instead of a conventional approach which repeatedly recalls the continuous tone image from memory and subsequently halftones it for display, the proposed method achieves significant memory efficiency by storing only the halftoned image and updating it in response to additional information received through progressive transmission. Thus the method requires only a single frame-buffer of bits for storage of the displayed binary image and no additional storage is required for the contone data. The additional image data received through progressive transmission is accommodated through in-place updates of the buffer. The method is thus particularly advantageous for high resolution bi-level displays where it can result in significant savings in memory. The proposed framework is implemented using a suitable multi-resolution, multi-level modification of error diffusion that is motivated by the presence of a single binary frame-buffer. Aggregates of individual display bits constitute the multiple output levels at a given resolution. This creates a natural progression of increasing resolution with decreasing bit-depth.

  3. Integral imaging based light field display with enhanced viewing resolution using holographic diffuser

    NASA Astrophysics Data System (ADS)

    Yan, Zhiqiang; Yan, Xingpeng; Jiang, Xiaoyu; Gao, Hui; Wen, Jun

    2017-11-01

    An integral imaging based light field display method is proposed by use of holographic diffuser, and enhanced viewing resolution is gained over conventional integral imaging systems. The holographic diffuser is fabricated with controlled diffusion characteristics, which interpolates the discrete light field of the reconstructed points to approximate the original light field. The viewing resolution can thus be improved and independent of the limitation imposed by Nyquist sampling frequency. An integral imaging system with low Nyquist sampling frequency is constructed, and reconstructed scenes of high viewing resolution using holographic diffuser are demonstrated, verifying the feasibility of the method.

  4. AM OLED using a-Si TFT backplane on flexible plastic substrate

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri R.; Schmidt, John; Roush, Jerry; Chanley, Charles; Dodd, Sonia R.

    2004-09-01

    Amorphous silicon TFT technology continues to show promise for fabricating large area high resolution flexible AM OLED displays. This paper describes the recent progress in the flexible AM OLED development efforts at Honeywell since our publication in this conference's proceedings in 2003, describing the feasibility of fabricating a 64x64 pixel AM OLED on a flexible plastic substrate. In this paper we describe the design, and fabrication of a 160x160(x3) pixel AM OLED on a flexible plastic substrate with an equivalent 80cgpi resolution. Flexibility characteristics of the fabricated displays are discussed. Further advances and improvements required for extending the size and resolution of flexible AM OLED displays are discussed.

  5. Super long viewing distance light homogeneous emitting three-dimensional display

    NASA Astrophysics Data System (ADS)

    Liao, Hongen

    2015-04-01

    Three-dimensional (3D) display technology has continuously been attracting public attention with the progress in today's 3D television and mature display technologies. The primary characteristics of conventional glasses-free autostereoscopic displays, such as spatial resolution, image depths, and viewing angle, are often limited due to the use of optical lenses or optical gratings. We present a 3D display using MEMS-scanning-mechanism-based light homogeneous emitting (LHE) approach and demonstrate that the display can directly generate an autostereoscopic 3D image without the need for optical lenses or gratings. The generated 3D image has the advantages of non-aberration and a high-definition spatial resolution, making it the first to exhibit animated 3D images with image depth of six meters. Our LHE 3D display approach can be used to generate a natural flat-panel 3D display with super long viewing distance and alternative real-time image update.

  6. Further advances in autostereoscopic technology at Dimension Technologies Inc.

    NASA Astrophysics Data System (ADS)

    Eichenlaub, Jesse B.

    1992-06-01

    Dimension Technologies is currently one of three companies offering autostereoscopic displays for sale and one of several which are actively pursuing advances to the technology. We have devised a new autostereoscopic imaging technique which possesses several advantages over previously explored methods. We are currently manufacturing autostereoscopic displays based on this technology, as well as vigorously pursuing research and development toward more advanced displays. During the past year, DTI has made major strides in advancing its LCD based autostereoscopic display technology. DTI has developed a color product -- a stand alone 640 X 480 flat panel LCD based 3-D display capable of accepting input from IBM PC and Apple MAC computers or TV cameras, and capable of changing from 3-D mode to 2-D mode with the flip of a switch. DTI is working on development of a prototype second generation color product that will provide autostereoscopic 3-D while allowing each eye to see the full resolution of the liquid crystal display. And development is also underway on a proof-of-concept display which produces hologram-like look-around images visible from a wide viewing angle, again while allowing the observer to see the full resolution of the display from all locations. Development of a high resolution prototype display of this type has begun.

  7. Math on a Sphere: Making Use of Public Displays in Education

    ERIC Educational Resources Information Center

    Eisenberg, Michael; Basman, Antranig; Hsi, Sherry

    2013-01-01

    Science on a Sphere (SoS) is a compelling educational display installed at numerous museums and planetariums around the world; essentially the SoS display is a large spherical surface on which multicolor high-resolution depictions of (e.g.) planetary weather maps may be depicted. Fascinating as the SoS display is, however, it is in practice…

  8. Scanning laser beam displays based on a 2D MEMS

    NASA Astrophysics Data System (ADS)

    Niesten, Maarten; Masood, Taha; Miller, Josh; Tauscher, Jason

    2010-05-01

    The combination of laser light sources and MEMS technology enables a range of display systems such as ultra small projectors for mobile devices, head-up displays for vehicles, wearable near-eye displays and projection systems for 3D imaging. Images are created by scanning red, green and blue lasers horizontally and vertically with a single two-dimensional MEMS. Due to the excellent beam quality of laser beams, the optical designs are efficient and compact. In addition, the laser illumination enables saturated display colors that are desirable for augmented reality applications where a virtual image is used. With this technology, the smallest projector engine for high volume manufacturing to date has been developed. This projector module has a height of 7 mm and a volume of 5 cc. The resolution of this projector is WVGA. No additional projection optics is required, resulting in an infinite focus depth. Unlike with micro-display projection displays, an increase in resolution will not lead to an increase in size or a decrease in efficiency. Therefore future projectors can be developed that combine a higher resolution in an even smaller and thinner form factor with increased efficiencies that will lead to lower power consumption.

  9. Flat-panel video resolution LED display system

    NASA Astrophysics Data System (ADS)

    Wareberg, P. G.; Kennedy, D. I.

    The system consists of a 128 x 128 element X-Y addressable LED array fabricated from green-emitting gallium phosphide. The LED array is interfaced with a 128 x 128 matrix TV camera. Associated electronics provides for seven levels of grey scale above zero with a grey scale ratio of square root of 2. Picture elements are on 0.008 inch centers resulting in a resolution of 125 lines-per-inch and a display area of approximately 1 sq. in. The LED array concept lends itself to modular construction, permitting assembly of a flat panel screen of any desired size from 1 x 1 inch building blocks without loss of resolution. A wide range of prospective aerospace applications exist extending from helmet-mounted systems involving small dedicated arrays to multimode cockpit displays constructed as modular screens. High-resolution LED arrays are already used as CRT replacements in military film-marking reconnaissance applications.

  10. High Resolution Mass Spectra Analysis with a Programmable Calculator.

    ERIC Educational Resources Information Center

    Holdsworth, David K.

    1980-01-01

    Highlighted are characteristics of programs written for a pocket-sized programmable calculator to analyze mass spectra data (such as displaying high resolution masses for formulas, predicting whether formulas are stable molecules or molecular ions, determining formulas by isotopic abundance measurement) in a laboratory or classroom. (CS)

  11. Display technologies; Proceedings of the Meeting, National Chiao Tung Univ., Hsinchu, Taiwan, Dec. 17, 18, 1992

    NASA Astrophysics Data System (ADS)

    Chen, Shu-Hsia; Wu, Shin-Tson

    1992-10-01

    A broad range of interdisciplinary subjects related to display technologies is addressed, with emphasis on high-definition displays, CRTs, projection displays, materials for display application, flat-panel displays, display modeling, and polymer-dispersed liquid crystals. Particular attention is given to a CRT approach to high-definition television display, a superhigh-resolution electron gun for color display CRT, a review of active-matrix liquid-crystal displays, color design for LCD parameters in projection and direct-view applications, annealing effects on ZnS:TbF3 electroluminescent devices prepared by RF sputtering, polycrystalline silicon thin film transistors with low-temperature gate dielectrics, refractive index dispersions of liquid crystals, a new rapid-response polymer-dispersed liquid-crystal material, and improved liquid crystals for active-matrix displays using high-tilt-orientation layers. (No individual items are abstracted in this volume)

  12. Bibliography of In-House and Contract Reports. Supplement 17

    DTIC Science & Technology

    1991-10-01

    Area Exit Pupil Viewer ETL-0399 1985 63 TILE REPORT NO. YEAR Extension of Kendall’s Concordance Test Where ETL-0316 1983 Ties are Allowed, An Extraction...Phase 11 ETL-0360 1984 High Resolution Optical Power Spectrum Analyzer ETL-0127 1978 High Resolution Orthophoto Output Table (HIROOT) AD 856 731L 1969...High Resolution Orthophoto Output Table ETL-ETR-72-3 1972 High Speed Disc Memory and a Color Image AD 878 975L 1970 Display for a Small Computer High

  13. Accommodation response measurements for integral 3D image

    NASA Astrophysics Data System (ADS)

    Hiura, H.; Mishina, T.; Arai, J.; Iwadate, Y.

    2014-03-01

    We measured accommodation responses under integral photography (IP), binocular stereoscopic, and real object display conditions, and viewing conditions of binocular and monocular viewing conditions. The equipment we used was an optometric device and a 3D display. We developed the 3D display for IP and binocular stereoscopic images that comprises a high-resolution liquid crystal display (LCD) and a high-density lens array. The LCD has a resolution of 468 dpi and a diagonal size of 4.8 inches. The high-density lens array comprises 106 x 69 micro lenses that have a focal length of 3 mm and diameter of 1 mm. The lenses are arranged in a honeycomb pattern. The 3D display was positioned 60 cm from an observer under IP and binocular stereoscopic display conditions. The target was presented at eight depth positions relative to the 3D display: 15, 10, and 5 cm in front of the 3D display, on the 3D display panel, and 5, 10, 15 and 30 cm behind the 3D display under the IP and binocular stereoscopic display conditions. Under the real object display condition, the target was displayed on the 3D display panel, and the 3D display was placed at the eight positions. The results suggest that the IP image induced more natural accommodation responses compared to the binocular stereoscopic image. The accommodation responses of the IP image were weaker than those of a real object; however, they showed a similar tendency with those of the real object under the two viewing conditions. Therefore, IP can induce accommodation to the depth positions of 3D images.

  14. A 360-degree floating 3D display based on light field regeneration.

    PubMed

    Xia, Xinxing; Liu, Xu; Li, Haifeng; Zheng, Zhenrong; Wang, Han; Peng, Yifan; Shen, Weidong

    2013-05-06

    Using light field reconstruction technique, we can display a floating 3D scene in the air, which is 360-degree surrounding viewable with correct occlusion effect. A high-frame-rate color projector and flat light field scanning screen are used in the system to create the light field of real 3D scene in the air above the spinning screen. The principle and display performance of this approach are investigated in this paper. The image synthesis method for all the surrounding viewpoints is analyzed, and the 3D spatial resolution and angular resolution of the common display zone are employed to evaluate display performance. The prototype is achieved and the real 3D color animation image has been presented vividly. The experimental results verified the representability of this method.

  15. High-speed reconstruction of compressed images

    NASA Astrophysics Data System (ADS)

    Cox, Jerome R., Jr.; Moore, Stephen M.

    1990-07-01

    A compression scheme is described that allows high-definition radiological images with greater than 8-bit intensity resolution to be represented by 8-bit pixels. Reconstruction of the images with their original intensity resolution can be carried out by means of a pipeline architecture suitable for compact, high-speed implementation. A reconstruction system is described that can be fabricated according to this approach and placed between an 8-bit display buffer and the display's video system thereby allowing contrast control of images at video rates. Results for 50 CR chest images are described showing that error-free reconstruction of the original 10-bit CR images can be achieved.

  16. Small feature sizes and high aperture ratio organic light-emitting diodes by using laser-patterned polyimide shadow masks

    NASA Astrophysics Data System (ADS)

    Kajiyama, Yoshitaka; Joseph, Kevin; Kajiyama, Koichi; Kudo, Shuji; Aziz, Hany

    2014-02-01

    A shadow mask technique capable of realizing high resolution (>330 pixel-per-inch) and ˜100% aperture ratio Organic Light-Emitting Diode (OLED) full color displays is demonstrated. The technique utilizes polyimide contact shadow masks, patterned by laser ablation. Red, green, and blue OLEDs with very small feature sizes (<25 μm) are fabricated side by side on one substrate. OLEDs fabricated via this technique have the same performance as those made by established technology. This technique has a strong potential to achieve high resolution OLED displays via standard vacuum deposition processes even on flexible substrates.

  17. Large laser projection displays utilizing all-solid-state RGB lasers

    NASA Astrophysics Data System (ADS)

    Xu, Zuyan; Bi, Yong

    2005-01-01

    RGB lasers projection displays have the advantages of producing large color triangle, high color saturation and high image resolution. In this report, with more than 4W white light synthesized by red (671nm), green (532nm) and blue (473nm) lasers, a RGB laser projection display system based on diode pumped solid-state lasers is developed and the performance of brilliant and vivid DVD dynamitic pictures on 60 inch screen is demonstrated.

  18. Two-panel LCOS-based projection system: a potentially compact high-resolution avionics display

    NASA Astrophysics Data System (ADS)

    Sharp, Gary D.; Chen, Jianmin; Robinson, Michael B.; Korah, John K.

    2003-09-01

    Military displays have been limited first by the availability of CRT and then AMLCD for color multifunctional displays. Projection display technology has been offered as an alternative. With the growth of the LCOS based consumer projection display industry, commercially off the shelf (COTS) components and technology are becoming readily available. A projection display system addresses the lessons learned from the CRT or AMLCD based attempts. This approach presents multiple vendors and user defined aspect ratio, resolution, brightness and color. This paper will present the latest work at ColorLink, Inc. on a two-panel LCOS based projection light engine developed for the consumer industry driven Rear Projection Television (RPTV) market. This engine demonstrates throughput, contrast and color performance that exceeds military requirements using COTS technology and components. We will introduce the core technology and philosophy followed by this industry in defining such a product.

  19. Bibliography of In-House and Contract Reports. Supplement 16

    DTIC Science & Technology

    1989-10-01

    Differences from ETL-71-CR-10 1971 Grav,t% and Gravity Gradients 54 TiLE REPORT NO. YEAR Determination of Level Sensitivity (Field ETL-RN-74-4 1974...Data Base Study, Phase II ETL-0360 1984 High Resolution Optical Power Spectrum Analyzer ETL-0127 1978 High Resolution Orthophoto Output Table (HIROOT...AD 856 731L 1969 High Resolution Orthophoto Output Table ETL-ETR-72-3 1972 High Speed Disc Memory and a Color Image AD 878 975L 1970 Display for a

  20. The Effect of Resolution on Detecting Visually Salient Preattentive Features

    DTIC Science & Technology

    2015-06-01

    resolutions in descending order (a–e). The plot compiles the areas of interest displayed in the images and each symbol represents 1 of the images. Data...to particular regions in a scene by highly salient 2 features, for example, the color of the flower discussed in the previous example. These...descending order (a–e). The plot compiles the areas of interest displayed in the images and each symbol represents 1 of the images. Data clusters

  1. LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System

    PubMed Central

    Keleshis, C; Ionita, CN; Yadava, G; Patel, V; Bednarek, DR; Hoffmann, KR; Verevkin, A; Rudin, S

    2008-01-01

    A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873) PMID:18836570

  2. LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System.

    PubMed

    Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S

    2008-01-01

    A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).

  3. User Friendly Real Time Display

    NASA Astrophysics Data System (ADS)

    McCarthy, Denise M.; McCracken, Bill

    1989-02-01

    Real-time viewing of high resolution infrared line scan reconnaissance imagery is greatly facilitated using Honeywell's Real Time Display in conjunction with a D-500 Infrared Reconnaissance System. The Real-Time Display (RTD) provides the capability of on-board review of high resolution infrared imagery using the wide infrared dynamic range of the D-500 infrared receiver to maximum advantage. The scan converter accepts, processes, and displays imagery from four channels of the IR Receiver after formatting by a multiplexer. The scan converter interfaces with a standard RS-170 video monitor. Detailed review and on-board analysis of infrared reconnaissance imagery stored on a videotape is easily accomplished using the many user-friendly features of the RTD. Using a convenient joystick controller, on-screen mode menus, and a moveable cursor, the operator can examine scenes of interest at four different display magnifications using a four step bidirectional zoom. Imagery areas of interest are first noted using the scrolling wide field display mode at 8x reduced display resolution. On noting an area of interest, the imagery can be marked on the tape record for future recovery and a freeze frame mode can be initiated. The operator can then move the cursor to the area of interest and zoom to higher display magnification for 4x, 2x, and lx display resolutions so that the full 4096 x 4096 pixel infrared frame can be matched to the 512 x 512 pixel display frame. At 8x wide field display magnification the full line scanner field of view is displayed at 8x reduced resolution. There are two selectable modes of obtaining this reduced resolution. The operator can use the default method, which averages the signal from an 8 x 8 pixel group, or it is also possible to select the peak signal of the 8 x 8 pixel block to represent the entire block on the display. In this alternate peak-signal display the wide field can be effectively scanned for hot objects which are more likely to be candidate targets. The intermediate 4x and 2x zoom steps are very useful in maintaining operator orientation in examining target clusters and industrial complexes. The four operating modes of the RTD are described and their use to the operator on a typical mission is outlined. Some installation details are given. The RTD as part of a complete D-500 Infrared Linescan Reconnaissance System is now being installed on a Beech 1900 Environmental Control Aircraft to monitor pollution in very sensitive and commercially important marine ecologies. Its application on military reconnaissance missions will allow the normal review of recorded videotape imagery at a ground station immediately after return of the aircraft to base. The areas of highest interest will have been previously marked during the airborne real-time review by the operator. The RTD packages into only two Line Replaceable Units (LRUs), a Scan Converter, and a Control Unit which includes a joystick hand controller. The CRT display is assumed to be part of the aircraft.

  4. Recent advances in a linear micromirror array for high-resolution projection

    NASA Astrophysics Data System (ADS)

    Picard, Francis; Doucet, Michel; Niall, Keith K.; Larouche, Carl; Savard, Maxime; Crisan, Silviu; Thibault, Simon; Jerominek, Hubert

    2004-05-01

    The visual displays of contemporary military flight simulators lack adequate definition to represent scenes in basic fast-jet fighter tasks. For example, air-to-air and air-to-ground targets are not projected with sufficient contrast and resolution for a pilot to perceive aspect, aspect rate and object detail at real world slant ranges. Simulator display geometries require the development of ultra-high resolution projectors with greater than 20 megapixel resolution at 60 Hz frame rate. A new micromirror device has been developed to address this requirement; it is able to modulate light intensity in an analog fashion with switching times shorter than 5 μs. When combined with a scanner, a laser and Schlieren optics, a linear array of these flexible micromirrors can display images composed of thousands of lines at a frame rate of 60 Hz. Recent results related to evaluation of this technology for high resolution projection are presented. Alternate operation modes for light modulation with flexible micromirrors are proposed. The related importance of controlling the residual micromirror curvature is discussed and results of experiments investigating the use of the deposition pressure to achieve such control are reported. Moreover, activities aiming at minimizing the micromirror response time and, so doing, maximizing the number of image columns per image frame are discussed. Finally, contrast measurement and estimate of the contrast limit achievable with the flexible micromirror technology are presented. All reported activities support the development of a fully addressable 2000-element micromirror array.

  5. Wide-Field-of-View, High-Resolution, Stereoscopic Imager

    NASA Technical Reports Server (NTRS)

    Prechtl, Eric F.; Sedwick, Raymond J.

    2010-01-01

    A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.

  6. Virtual reality 3D headset based on DMD light modulators

    NASA Astrophysics Data System (ADS)

    Bernacki, Bruce E.; Evans, Allan; Tang, Edward

    2014-06-01

    We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micromirror devices (DMD). Current methods for presenting information for virtual reality are focused on either polarizationbased modulators such as liquid crystal on silicon (LCoS) devices, or miniature LCD or LED displays often using lenses to place the image at infinity. LCoS modulators are an area of active research and development, and reduce the amount of viewing light by 50% due to the use of polarization. Viewable LCD or LED screens may suffer low resolution, cause eye fatigue, and exhibit a "screen door" or pixelation effect due to the low pixel fill factor. Our approach leverages a mature technology based on silicon micro mirrors delivering 720p resolution displays in a small form-factor with high fill factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high-definition resolution and low power consumption, and many of the design methods developed for DMD projector applications can be adapted to display use. Potential applications include night driving with natural depth perception, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design concept is described in which light from the DMD is imaged to infinity and the user's own eye lens forms a real image on the user's retina resulting in a virtual retinal display.

  7. Research of an optimization design method of integral imaging three-dimensional display system

    NASA Astrophysics Data System (ADS)

    Gao, Hui; Yan, Zhiqiang; Wen, Jun; Jiang, Guanwu

    2016-03-01

    The information warfare needs a highly transparent environment of battlefield, it follows that true three-dimensional display technology has obvious advantages than traditional display technology in the current field of military science and technology. It also focuses on the research progress of lens array imaging technology and aims at what restrict the development of integral imaging, main including low spatial resolution, narrow depth range and small viewing angle. This paper summarizes the principle, characteristics and development history of the integral imaging. A variety of methods are compared and analyzed that how to improve the resolution, extend depth of field, increase scope and eliminate the artifact aiming at problems currently. And makes a discussion about the experimental results of the research, comparing the display performance of different methods.

  8. Scalable large format 3D displays

    NASA Astrophysics Data System (ADS)

    Chang, Nelson L.; Damera-Venkata, Niranjan

    2010-02-01

    We present a general framework for the modeling and optimization of scalable large format 3-D displays using multiple projectors. Based on this framework, we derive algorithms that can robustly optimize the visual quality of an arbitrary combination of projectors (e.g. tiled, superimposed, combinations of the two) without manual adjustment. The framework creates for the first time a new unified paradigm that is agnostic to a particular configuration of projectors yet robustly optimizes for the brightness, contrast, and resolution of that configuration. In addition, we demonstrate that our algorithms support high resolution stereoscopic video at real-time interactive frame rates achieved on commodity graphics hardware. Through complementary polarization, the framework creates high quality multi-projector 3-D displays at low hardware and operational cost for a variety of applications including digital cinema, visualization, and command-and-control walls.

  9. A High Resolution Graphic Input System for Interactive Graphic Display Terminals. Appendix B.

    ERIC Educational Resources Information Center

    Van Arsdall, Paul Jon

    The search for a satisfactory computer graphics input system led to this version of an analog sheet encoder which is transparent and requires no special probes. The goal of the research was to provide high resolution touch input capabilities for an experimental minicomputer based intelligent terminal system. The technique explored is compatible…

  10. Efficient, deep-blue TADF-emitters for OLED display applications (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Volz, Daniel; Baumann, Thomas

    2016-09-01

    Currently, the mobile display market is strongly shifting towards AMOLED technology, in order to enable curved and flexible displays. This leads to a growing demand for highly efficient OLED emitters to reduce the power consumption and increase display resolution at the same time. While highly efficient green and red OLEDs already found their place in commercial OLED-displays, the lack of efficient blue emitters is still an issue. Consequently, the active area for blue is considerably larger than for green and red pixels, to make up for the lower efficiency. We intend to close this efficiency-gap with novel emitters based on thermally activated delayed fluorescence (TADF) technology. Compared to state-of-the-art fluorescent dopants, the efficiency of TADF-emitters is up to four times higher. At the same time, it is possible to design them in a way to maintain deep blue emission, i.e. CIE y < 0.2. These aspects are relevant to produce efficient high resolution AMOLED displays. Apart from these direct customer benefits, our TADF technology does not contain any rare elements, which allows for the fabrication of sustainable OLED technology. In this work, we highlight one of our recently developed blue TADF materials. Basic material properties as well as first device results are discussed. In a bottom-emitting device, a CIEx/CIEy coordinate of (0.16/0.17) was achieved with efficiency values close to 20% EQE.

  11. Evaluation of precipitation extremes over the Asian domain: observation and modelling studies

    NASA Astrophysics Data System (ADS)

    Kim, In-Won; Oh, Jaiho; Woo, Sumin; Kripalani, R. H.

    2018-04-01

    In this study, a comparison in the precipitation extremes as exhibited by the seven reference datasets is made to ascertain whether the inferences based on these datasets agree or they differ. These seven datasets, roughly grouped in three categories i.e. rain-gauge based (APHRODITE, CPC-UNI), satellite-based (TRMM, GPCP1DD) and reanalysis based (ERA-Interim, MERRA, and JRA55), having a common data period 1998-2007 are considered. Focus is to examine precipitation extremes in the summer monsoon rainfall over South Asia, East Asia and Southeast Asia. Measures of extreme precipitation include the percentile thresholds, frequency of extreme precipitation events and other quantities. Results reveal that the differences in displaying extremes among the datasets are small over South Asia and East Asia but large differences among the datasets are displayed over the Southeast Asian region including the maritime continent. Furthermore, precipitation data appear to be more consistent over East Asia among the seven datasets. Decadal trends in extreme precipitation are consistent with known results over South and East Asia. No trends in extreme precipitation events are exhibited over Southeast Asia. Outputs of the Coupled Model Intercomparison Project Phase 5 (CMIP5) simulation data are categorized as high, medium and low-resolution models. The regions displaying maximum intensity of extreme precipitation appear to be dependent on model resolution. High-resolution models simulate maximum intensity of extreme precipitation over the Indian sub-continent, medium-resolution models over northeast India and South China and the low-resolution models over Bangladesh, Myanmar and Thailand. In summary, there are differences in displaying extreme precipitation statistics among the seven datasets considered here and among the 29 CMIP5 model data outputs.

  12. High-resolution laser-projection display system using a grating electromechanical system (GEMS)

    NASA Astrophysics Data System (ADS)

    Brazas, John C.; Kowarz, Marek W.

    2004-01-01

    Eastman Kodak Company has developed a diffractive-MEMS spatial-light modulator for use in printing and display applications, the grating electromechanical system (GEMS). This modulator contains a linear array of pixels capable of high-speed digital operation, high optical contrast, and good efficiency. The device operation is based on deflection of electromechanical ribbons suspended above a silicon substrate by a series of intermediate supports. When electrostatically actuated, the ribbons conform to the supporting substructure to produce a surface-relief phase grating over a wide active region. The device is designed to be binary, switching between a reflective mirror state having suspended ribbons and a diffractive grating state having ribbons in contact with substrate features. Switching times of less than 50 nanoseconds with sub-nanosecond jitter are made possible by reliable contact-mode operation. The GEMS device can be used as a high-speed digital-optical modulator for a laser-projection display system by collecting the diffracted orders and taking advantage of the low jitter. A color channel is created using a linear array of individually addressable GEMS pixels. A two-dimensional image is produced by sweeping the line image of the array, created by the projection optics, across the display screen. Gray levels in the image are formed using pulse-width modulation (PWM). A high-resolution projection display was developed using three 1080-pixel devices illuminated by red, green, and blue laser-color primaries. The result is an HDTV-format display capable of producing stunning still and motion images with very wide color gamut.

  13. The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human Simulator

    PubMed Central

    Wachter, S. Blake; Johnson, Ken; Albert, Robert; Syroid, Noah; Drews, Frank; Westenskow, Dwayne

    2006-01-01

    Objective Authors developed a picture-graphics display for pulmonary function to present typical respiratory data used in perioperative and intensive care environments. The display utilizes color, shape and emergent alerting to highlight abnormal pulmonary physiology. The display serves as an adjunct to traditional operating room displays and monitors. Design To evaluate the prototype, nineteen clinician volunteers each managed four adverse respiratory events and one normal event using a high-resolution patient simulator which included the new displays (intervention subjects) and traditional displays (control subjects). Between-group comparisons included (i) time to diagnosis and treatment for each adverse respiratory event; (ii) the number of unnecessary treatments during the normal scenario; and (iii) self-reported workload estimates while managing study events. Measurements Two expert anesthesiologists reviewed video-taped transcriptions of the volunteers to determine time to treat and time to diagnosis. Time values were then compared between groups using a Mann-Whitney-U Test. Estimated workload for both groups was assessed using the NASA-TLX and compared between groups using an ANOVA. P-values < 0.05 were considered significant. Results Clinician volunteers detected and treated obstructed endotracheal tubes and intrinsic PEEP problems faster with graphical rather than conventional displays (p < 0.05). During the normal scenario simulation, 3 clinicians using the graphical display, and 5 clinicians using the conventional display gave unnecessary treatments. Clinician-volunteers reported significantly lower subjective workloads using the graphical display for the obstructed endotracheal tube scenario (p < 0.001) and the intrinsic PEEP scenario (p < 0.03). Conclusion Authors conclude that the graphical pulmonary display may serve as a useful adjunct to traditional displays in identifying adverse respiratory events. PMID:16929038

  14. IceT users' guide and reference.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreland, Kenneth D.

    2011-01-01

    The Image Composition Engine for Tiles (IceT) is a high-performance sort-last parallel rendering library. In addition to providing accelerated rendering for a standard display, IceT provides the unique ability to generate images for tiled displays. The overall resolution of the display may be several times larger than any viewport that may be rendered by a single machine. This document is an overview of the user interface to IceT.

  15. A hierarchical pyramid method for managing large-scale high-resolution drainage networks extracted from DEM

    NASA Astrophysics Data System (ADS)

    Bai, Rui; Tiejian, Li; Huang, Yuefei; Jiaye, Li; Wang, Guangqian; Yin, Dongqin

    2015-12-01

    The increasing resolution of Digital Elevation Models (DEMs) and the development of drainage network extraction algorithms make it possible to develop high-resolution drainage networks for large river basins. These vector networks contain massive numbers of river reaches with associated geographical features, including topological connections and topographical parameters. These features create challenges for efficient map display and data management. Of particular interest are the requirements of data management for multi-scale hydrological simulations using multi-resolution river networks. In this paper, a hierarchical pyramid method is proposed, which generates coarsened vector drainage networks from the originals iteratively. The method is based on the Horton-Strahler's (H-S) order schema. At each coarsening step, the river reaches with the lowest H-S order are pruned, and their related sub-basins are merged. At the same time, the topological connections and topographical parameters of each coarsened drainage network are inherited from the former level using formulas that are presented in this study. The method was applied to the original drainage networks of a watershed in the Huangfuchuan River basin extracted from a 1-m-resolution airborne LiDAR DEM and applied to the full Yangtze River basin in China, which was extracted from a 30-m-resolution ASTER GDEM. In addition, a map-display and parameter-query web service was published for the Mississippi River basin, and its data were extracted from the 30-m-resolution ASTER GDEM. The results presented in this study indicate that the developed method can effectively manage and display massive amounts of drainage network data and can facilitate multi-scale hydrological simulations.

  16. Glasses-free large size high-resolution three-dimensional display based on the projector array

    NASA Astrophysics Data System (ADS)

    Sang, Xinzhu; Wang, Peng; Yu, Xunbo; Zhao, Tianqi; Gao, Xing; Xing, Shujun; Yu, Chongxiu; Xu, Daxiong

    2014-11-01

    Normally, it requires a huge amount of spatial information to increase the number of views and to provide smooth motion parallax for natural three-dimensional (3D) display similar to real life. To realize natural 3D video display without eye-wears, a huge amount of 3D spatial information is normal required. However, minimum 3D information for eyes should be used to reduce the requirements for display devices and processing time. For the 3D display with smooth motion parallax similar to the holographic stereogram, the size the virtual viewing slit should be smaller than the pupil size of eye at the largest viewing distance. To increase the resolution, two glass-free 3D display systems rear and front projection are presented based on the space multiplexing with the micro-projector array and the special designed 3D diffuse screens with the size above 1.8 m× 1.2 m. The displayed clear depths are larger 1.5m. The flexibility in terms of digitized recording and reconstructed based on the 3D diffuse screen relieves the limitations of conventional 3D display technologies, which can realize fully continuous, natural 3-D display. In the display system, the aberration is well suppressed and the low crosstalk is achieved.

  17. Scanning instrumentation for measuring magnetic field trapping in high Tc superconductors

    NASA Technical Reports Server (NTRS)

    Sisk, R. C.; Helton, A. J.

    1993-01-01

    Computerized scanning instrumentation measures and displays trapped magnetic fields across the surface of high Tc superconductors at 77 K. Data are acquired in the form of a raster scan image utilizing stepping motor stages for positioning and a cryogenic Hall probe for magnetic field readout. Flat areas up to 45 mm in diameter are scanned with 0.5-mm resolution and displayed as false color images.

  18. Recent advances and product enhancements in reflective cholesteric displays

    NASA Astrophysics Data System (ADS)

    Khan, Asad; Schneider, Tod; Miller, Nick; Marhefka, Duane; Ernst, Todd; Nicholson, Forrest; Doane, Joseph W.

    2005-04-01

    Bistable reflective cholesteric displays are a liquid crystal display technology developed to fill a market need for very low power displays on a low-cost, high resolution passive matrix. Their unique look, high reflectivity, bistability, and simple structure make them an ideal flat panel display choice for handheld or other portable devices where small lightweight batteries with long lifetimes are important. We discuss recent advances in cholesteric display technology at Kent Displays such as progress towards single layer black and white displays, standard products, lower cost display modules, and various interface options for cholesteric display applications. It will be shown that inclusion of radio frequency (rf) control options and serial peripheral interface (spi) can greatly enhance the cholesteric display module market penetration by enabling quick integration into end devices. Finally, some discussion will be on the progress of the development of flexible reflective cholesteric displays. These flexible displays can dramatically change industrial design methods by enabling curved surfaces with displays integrated in them. Additional discussion in the paper will include applications of various display modes including signs, hand held instrumentation, and the electronic book and reader.

  19. A volumetric three-dimensional digital light photoactivatable dye display

    NASA Astrophysics Data System (ADS)

    Patel, Shreya K.; Cao, Jian; Lippert, Alexander R.

    2017-07-01

    Volumetric three-dimensional displays offer spatially accurate representations of images with a 360° view, but have been difficult to implement due to complex fabrication requirements. Herein, a chemically enabled volumetric 3D digital light photoactivatable dye display (3D Light PAD) is reported. The operating principle relies on photoactivatable dyes that become reversibly fluorescent upon illumination with ultraviolet light. Proper tuning of kinetics and emission wavelengths enables the generation of a spatial pattern of fluorescent emission at the intersection of two structured light beams. A first-generation 3D Light PAD was fabricated using the photoactivatable dye N-phenyl spirolactam rhodamine B, a commercial picoprojector, an ultraviolet projector and a custom quartz imaging chamber. The system displays a minimum voxel size of 0.68 mm3, 200 μm resolution and good stability over repeated `on-off' cycles. A range of high-resolution 3D images and animations can be projected, setting the foundation for widely accessible volumetric 3D displays.

  20. A volumetric three-dimensional digital light photoactivatable dye display

    PubMed Central

    Patel, Shreya K.; Cao, Jian; Lippert, Alexander R.

    2017-01-01

    Volumetric three-dimensional displays offer spatially accurate representations of images with a 360° view, but have been difficult to implement due to complex fabrication requirements. Herein, a chemically enabled volumetric 3D digital light photoactivatable dye display (3D Light PAD) is reported. The operating principle relies on photoactivatable dyes that become reversibly fluorescent upon illumination with ultraviolet light. Proper tuning of kinetics and emission wavelengths enables the generation of a spatial pattern of fluorescent emission at the intersection of two structured light beams. A first-generation 3D Light PAD was fabricated using the photoactivatable dye N-phenyl spirolactam rhodamine B, a commercial picoprojector, an ultraviolet projector and a custom quartz imaging chamber. The system displays a minimum voxel size of 0.68 mm3, 200 μm resolution and good stability over repeated ‘on-off’ cycles. A range of high-resolution 3D images and animations can be projected, setting the foundation for widely accessible volumetric 3D displays. PMID:28695887

  1. Writing next-generation display photomasks

    NASA Astrophysics Data System (ADS)

    Sandstrom, Tor; Wahlsten, Mikael; Park, Youngjin

    2016-10-01

    Recent years have seen a fast technical development within the display area. Displays get ever higher pixel density and the pixels get smaller. Current displays have over 800 PPI and market forces will eventually drive for densities of 2000 PPI or higher. The transistor backplanes also get more complex. OLED displays require 4-7 transistors per pixel instead of the typical 1-2 transistors used for LCDs, and they are significantly more sensitive to errors. New large-area maskwriters have been developed for masks used in high volume production of screens for state-of-theart smartphones. Redesigned laser optics with higher NA and lower aberrations improve resolution and CD uniformity and reduce mura effects. The number of beams has been increased to maintain the throughput despite the higher writing resolution. OLED displays are highly sensitive to placement errors and registration in the writers has been improved. To verify the registration of produced masks a separate metrology system has been developed. The metrology system is self-calibrated to high accuracy. The calibration is repeatable across machines and sites using Z-correction. The repeatability of the coordinate system makes it possible to standardize the coordinate system across an entire supply chain or indeed across the entire industry. In-house metrology is a commercial necessity for high-end mask shop, but also the users of the masks, the panel makers, would benefit from having in-house metrology. It would act as the reference for their mask suppliers, give better predictive and post mortem diagnostic power for the panel process, and the metrology could be used to characterize and improve the entire production loop from data to panel.

  2. A multi-directional backlight for a wide-angle, glasses-free three-dimensional display.

    PubMed

    Fattal, David; Peng, Zhen; Tran, Tho; Vo, Sonny; Fiorentino, Marco; Brug, Jim; Beausoleil, Raymond G

    2013-03-21

    Multiview three-dimensional (3D) displays can project the correct perspectives of a 3D image in many spatial directions simultaneously. They provide a 3D stereoscopic experience to many viewers at the same time with full motion parallax and do not require special glasses or eye tracking. None of the leading multiview 3D solutions is particularly well suited to mobile devices (watches, mobile phones or tablets), which require the combination of a thin, portable form factor, a high spatial resolution and a wide full-parallax view zone (for short viewing distance from potentially steep angles). Here we introduce a multi-directional diffractive backlight technology that permits the rendering of high-resolution, full-parallax 3D images in a very wide view zone (up to 180 degrees in principle) at an observation distance of up to a metre. The key to our design is a guided-wave illumination technique based on light-emitting diodes that produces wide-angle multiview images in colour from a thin planar transparent lightguide. Pixels associated with different views or colours are spatially multiplexed and can be independently addressed and modulated at video rate using an external shutter plane. To illustrate the capabilities of this technology, we use simple ink masks or a high-resolution commercial liquid-crystal display unit to demonstrate passive and active (30 frames per second) modulation of a 64-view backlight, producing 3D images with a spatial resolution of 88 pixels per inch and full-motion parallax in an unprecedented view zone of 90 degrees. We also present several transparent hand-held prototypes showing animated sequences of up to six different 200-view images at a resolution of 127 pixels per inch.

  3. Arthroscopic knee surgery using the advanced flat panel high-resolution color head-mounted display

    NASA Astrophysics Data System (ADS)

    Nelson, Scott A.; Jones, D. E. Casey; St. Pierre, Patrick; Sampson, James B.

    1997-06-01

    The first ever deployed arthroscopic knee surgeries have been performed using a high resolution color head-mounted display (HMD) developed under the DARPA Advanced Flat Panel HMD program. THese procedures and several fixed hospital procedures have allowed both the system designers and surgeons to gain new insight into the use of a HMD for medical procedures in both community and combat support hospitals scenarios. The surgeons demonstrated and reported improved head-body orientation and awareness while using the HMD and reported several advantages and disadvantages of the HMD as compared to traditional CRT monitor viewing of the arthroscopic video images. The surgeries, the surgeon's comments, and a human factors overview of HMDs for Army surgical applications are discussed here.

  4. WebPresent: a World Wide Web-based telepresentation tool for physicians

    NASA Astrophysics Data System (ADS)

    Sampath-Kumar, Srihari; Banerjea, Anindo; Moshfeghi, Mehran

    1997-05-01

    In this paper, we present the design architecture and the implementation status of WebPresent - a world wide web based tele-presentation tool. This tool allows a physician to use a conference server workstation and make a presentation of patient cases to a geographically distributed audience. The audience consists of other physicians collaborating on patients' health care management and physicians participating in continuing medical education. These physicians are at several locations with networks of different bandwidth and capabilities connecting them. Audiences also receive the patient case information on different computers ranging form high-end display workstations to laptops with low-resolution displays. WebPresent is a scalable networked multimedia tool which supports the presentation of hypertext, images, audio, video, and a white-board to remote physicians with hospital Intranet access. WebPresent allows the audience to receive customized information. The data received can differ in resolution and bandwidth, depending on the availability of resources such as display resolution and network bandwidth.

  5. An update of commercial infrared sensing and imaging instruments

    NASA Technical Reports Server (NTRS)

    Kaplan, Herbert

    1989-01-01

    A classification of infrared sensing instruments by type and application, listing commercially available instruments, from single point thermal probes to on-line control sensors, to high speed, high resolution imaging systems is given. A review of performance specifications follows, along with a discussion of typical thermographic display approaches utilized by various imager manufacturers. An update report on new instruments, new display techniques and newly introduced features of existing instruments is given.

  6. Development and Translation of Hybrid Optoacoustic/Ultrasonic Tomography for Early Breast Cancer Detection

    DTIC Science & Technology

    2015-09-01

    OAT) and laser-induced ultrasound tomography (LUT) to obtain coregistered maps of tissue optical absorption and speed of sound , displayed within the...computed tomography (UST) can provide high-resolution anatomical images of breast lesions based on three complementary acoustic properties (speed-of- sound ...tomography (UST) can provide high-resolution anatomical images of breast lesions based on three complementary acoustic properties (speed-of- sound

  7. Performance characterization of a single bi-axial scanning MEMS mirror-based head-worn display

    NASA Astrophysics Data System (ADS)

    Liang, Minhua

    2002-06-01

    The NomadTM Personal Display System is a head-worn display (HWD) with a see-through, high-resolution, high-luminance display capability. It is based on a single bi-axial scanning MEMS mirror. In the Nomad HWD system, a red laser diode emits a beam of light that is scanned bi-axially by a single MEMS mirror. A diffractive beam diffuser and an ocular expand the beam to form a 12mm exit pupil for comfortable viewing. The Nomad display has an SVGA (800x600) resolution, 60Hz frame rate, 23-degree horizontal field of view (FOV) and 3:4 vertical to horizontal aspect ratio, a luminance of 800~900 foot-Lamberts, see-through capability, 30mm eye-relief distance, and 1-foot to infinity focusing adjustment. We have characterized the performance parameters, such as field of view, distortion, contrast ratio (4x4 black and white checker board), modulation depth, exit pupil size, eye relief distance, maximum luminance, dynamic range ratio (full-on-to-full-off ratio), dimming ratio, and luminance uniformity at image plane. The Class-1 eye-safety requirements per IEC 60825-1 Amendment 2 (CDRH Laser Notice No. 50) are analyzed and verified by experiments. The paper describes all of the testing methods and set-ups as well as the representative test results. The test results demonstrate that the Nomad display is an eye-safe display product with good image quality and good user ergonomics.

  8. High resolution spectrograph. [for LST

    NASA Technical Reports Server (NTRS)

    Peacock, K.

    1975-01-01

    The high resolution spectrograph (HRS) is designed to be used with the Large Space Telescope (LST) for the study of spectra of point and extended targets in the spectral range 110 to 410 nm. It has spectral resolutions of 1,000; 30,000; and 100,000 and has a field of view as large as 10 arc sec. The spectral range and resolution are selectable using interchangeable optical components and an echelle spectrograph is used to display a cross dispersed spectrum on the photocathode of either of 2 SEC orthicon image tubes. Provisions are included for wavelength calibration, target identification and acquisition and thermal control. The system considerations of the instrument are described.

  9. Limitation of Liquid Crystal on Silicon Spatial Light Modular for Holographic Three-dimensional Displays

    NASA Technical Reports Server (NTRS)

    Wang, Xinghua; Wang, Bin; Bos, Philip J.; Anderson, James E.; Kujawinska, Malgorzata; Pouch, John; Miranda, Feliz

    2004-01-01

    In a 3-D display system based on an opto-electronic reconstruction of a digitally recorded hologram, the field of view of such a system is limited by the spatial resolution of the liquid crystal on silicon (LCOS) spatial light modular (SLM) used to perform the opto-electronic reconstruction. In this article, the special resolution limitation of LCOS SLM associated with the fringe field effect and interpixel coupling is determined by the liquid crystal detector simulation and the Finite Difference Time Domain (FDTD) simulation. The diffraction efficiency loss associated with the imperfection in the phase profile is studied with an example of opto-electronic reconstruction of an amplitude object. A high spatial resolution LCOS SLM with a wide reconstruction angle is proposed.

  10. Transmission of digital images within the NTSC analog format

    DOEpatents

    Nickel, George H.

    2004-06-15

    HDTV and NTSC compatible image communication is done in a single NTSC channel bandwidth. Luminance and chrominance image data of a scene to be transmitted is obtained. The image data is quantized and digitally encoded to form digital image data in HDTV transmission format having low-resolution terms and high-resolution terms. The low-resolution digital image data terms are transformed to a voltage signal corresponding to NTSC color subcarrier modulation with retrace blanking and color bursts to form a NTSC video signal. The NTSC video signal and the high-resolution digital image data terms are then transmitted in a composite NTSC video transmission. In a NTSC receiver, the NTSC video signal is processed directly to display the scene. In a HDTV receiver, the NTSC video signal is processed to invert the color subcarrier modulation to recover the low-resolution terms, where the recovered low-resolution terms are combined with the high-resolution terms to reconstruct the scene in a high definition format.

  11. Color Helmet-Mounted Display System for In-Flight Simulation on the RASCAL Research Helicopter

    NASA Technical Reports Server (NTRS)

    Edwards, Tim; Barnhart, Warren; Sawyer, Kevin; Aiken, Edwin W. (Technical Monitor)

    1995-01-01

    A high performance color helmet mounted display (HMD) system for in-flight simulation and research has been developed for the Rotorcraft Aircrew Systems Concepts Laboratory (RASCAL). The display system consists of a programmable display generator, a display electronics unit, a head tracker, and the helmet with display optics. The system provides a maximum of 1024 x 1280 resolution, a 4:1 contrast ratio, and a brightness of 1100fL utilizing currently available technologies. This paper describes the major features and components of the system. Also discussed are the measured performance of the system and the design techniques that allowed the development of a full color HMD.

  12. Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics

    NASA Astrophysics Data System (ADS)

    Tsai, Meng-Che; Lee, Tsung-Xian

    2017-02-01

    Due to the worldwide portable devices and illumination technology trends, researches interest in laser diodes applications are booming in recent years. One of the popular and potential LDs applications is near-eye display used in VR/AR. An ideal near-eye display needs to provide high resolution, wide FOV imagery with compact magnifying optics, and long battery life for prolonged use. However, previous studies still cannot reach high light utilization efficiency in illumination and imaging optical systems which should be raised as possible to increase wear comfort. To meet these needs, a waveguide illumination system of near-eye display is presented in this paper. We focused on proposing a high efficiency RGB LDs light engine which could reduce power consumption and increase flexibility of mechanism design by using freeform TIR reflectors instead of beam splitters. By these structures, the total system efficiency of near-eye display is successfully increased, and the improved results in efficiency and fabrication tolerance of near-eye displays are shown in this paper.

  13. Processing and characterization of high resolution GaN/InGaN LED arrays at 10 micron pitch for micro display applications

    NASA Astrophysics Data System (ADS)

    Dupré, Ludovic; Marra, Marjorie; Verney, Valentin; Aventurier, Bernard; Henry, Franck; Olivier, François; Tirano, Sauveur; Daami, Anis; Templier, François

    2017-02-01

    We report the fabrication process and characterization of high resolution 873 x 500 pixels emissive arrays based on blue or green GaN/InGaN light emitting diodes (LEDs) at a reduced pixel pitch of 10 μm. A self-aligned process along with a combination of damascene metallization steps is presented as the key to create a common cathode which is expected to provide good thermal dissipation and prevent voltage drops between center and side of the micro LED matrix. We will discuss the challenges of a self-aligned technology related to the choice of a good P contact metal and will present our solutions for the realization of the metallic interconnections between the GaN contacts and the higher levels of metallization at such a small pixel pitch. Enhanced control of each technological step allows scalability of the process up to 4 inch LED wafers and production of high quality LED arrays. The very high brightness (up to 107 cd.m-2) and good external quantum efficiency (EQE) of the resulting device make these kind of micro displays suitable for augmented reality or head up display applications.

  14. Computer programs to assist in high resolution thermal denaturation and circular dichroism studies on nucleic acids

    PubMed Central

    Goodman, Thomas C.; Hardies, Stephen C.; Cortez, Carlos; Hillen, Wolfgang

    1981-01-01

    Computer programs are described that direct the collection, processing, and graphical display of numerical data obtained from high resolution thermal denaturation (1-3) and circular dichroism (4) studies. Besides these specific applications, the programs may also be useful, either directly or as programming models, in other types of spectrophotometric studies employing computers, programming languages, or instruments similar to those described here (see Materials and Methods). PMID:7335498

  15. Optogenetic Stimulation of Peripheral Vagus Nerves using Flexible OLED Display Technology to Treat Chronic Inflammatory Disease and Mental Health Disorders

    DTIC Science & Technology

    2016-03-31

    transcutaneously via the outer ear using a high-resolution, addressable array of organic light emitting diodes (OLEDs) manufactured on a flexible...therapeutic optical stimulation in optogenetically modified neural tissue. Keywords: Optogenetics; neuromodulation; organic light emitting diode ...the outer ear using a high-resolution, two-dimensional (2-D), addressable array of red organic light - emitting diodes (OLEDs) manufactured on a thin

  16. High-Resolution Large-Field-of-View Ultrasound Breast Imager

    DTIC Science & Technology

    2013-06-01

    record the display of the AO detector for image processing and storage. The measured resolution is 400 microns. • The noise present in the imaging...l T 4 O igure 7: (Le n cyst thickn ask 3: Inco .a. Incorpor ensitivity (U e have not ideo camera enses. ask 4: Desi .a. Determin ur initial pl

  17. A color video display technique for flow field surveys

    NASA Technical Reports Server (NTRS)

    Winkelmann, A. E.; Tsao, C. P.

    1982-01-01

    A computer driven color video display technique has been developed for the presentation of wind tunnel flow field survey data. The results of both qualitative and quantitative flow field surveys can be presented in high spatial resolutions color coded displays. The technique has been used for data obtained with a hot-wire probe, a split-film probe, a Conrad (pitch) probe and a 5-tube pressure probe in surveys above and behind a wing with partially stalled and fully stalled flow.

  18. A Full-Color, High-Resolution Laser Projector for a Flight Simulator Visual Display

    DTIC Science & Technology

    1993-08-01

    current projection technology. Laser projection promises an increased color gamut , higher luminance, zero persistence, and increased line rate. The...1 7 List of Figures Fig. I Color Gamut of Laser Projection Display...primary wavelengths plot on the boundary of the ICI (CIE) chromaticity diagram; a characteristic that allows a very large gamut of colors. Unlike

  19. Pixel-level tunable liquid crystal lenses for auto-stereoscopic display

    NASA Astrophysics Data System (ADS)

    Li, Kun; Robertson, Brian; Pivnenko, Mike; Chu, Daping; Zhou, Jiong; Yao, Jun

    2014-02-01

    Mobile video and gaming are now widely used, and delivery of a glass-free 3D experience is of both research and development interest. The key drawbacks of a conventional 3D display based on a static lenticular lenslet array and parallax barriers are low resolution, limited viewing angle and reduced brightness, mainly because of the need of multiple-pixels for each object point. This study describes the concept and performance of pixel-level cylindrical liquid crystal (LC) lenses, which are designed to steer light to the left and right eye sequentially to form stereo parallax. The width of the LC lenses can be as small as 20-30 μm, so that the associated auto-stereoscopic display will have the same resolution as the 2D display panel in use. Such a thin sheet of tunable LC lens array can be applied directly on existing mobile displays, and can deliver 3D viewing experience while maintaining 2D viewing capability. Transparent electrodes were laser patterned to achieve the single pixel lens resolution, and a high birefringent LC material was used to realise a large diffraction angle for a wide field of view. Simulation was carried out to model the intensity profile at the viewing plane and optimise the lens array based on the measured LC phase profile. The measured viewing angle and intensity profile were compared with the simulation results.

  20. Sparse super-resolution reconstructions of video from mobile devices in digital TV broadcast applications

    NASA Astrophysics Data System (ADS)

    Boon, Choong S.; Guleryuz, Onur G.; Kawahara, Toshiro; Suzuki, Yoshinori

    2006-08-01

    We consider the mobile service scenario where video programming is broadcast to low-resolution wireless terminals. In such a scenario, broadcasters utilize simultaneous data services and bi-directional communications capabilities of the terminals in order to offer substantially enriched viewing experiences to users by allowing user participation and user tuned content. While users immediately benefit from this service when using their phones in mobile environments, the service is less appealing in stationary environments where a regular television provides competing programming at much higher display resolutions. We propose a fast super-resolution technique that allows the mobile terminals to show a much enhanced version of the broadcast video on nearby high-resolution devices, extending the appeal and usefulness of the broadcast service. The proposed single frame super-resolution algorithm uses recent sparse recovery results to provide high quality and high-resolution video reconstructions based solely on individual decoded frames provided by the low-resolution broadcast.

  1. Predictive displays for a process-control schematic interface.

    PubMed

    Yin, Shanqing; Wickens, Christopher D; Helander, Martin; Laberge, Jason C

    2015-02-01

    Our objective was to examine the extent to which increasing precision of predictive (rate of change) information in process control will improve performance on a simulated process-control task. Predictive displays have been found to be useful in process control (as well as aviation and maritime industries). However, authors of prior research have not examined the extent to which predictive value is increased by increasing predictor resolution, nor has such research tied potential improvements to changes in process control strategy. Fifty nonprofessional participants each controlled a simulated chemical mixture process (honey mixer simulation) that simulated the operations found in process control. Participants in each of five groups controlled with either no predictor or a predictor ranging in the resolution of prediction of the process. Increasing detail resolution generally increased the benefit of prediction over the control condition although not monotonically so. The best overall performance, combining quality and predictive ability, was obtained by the display of intermediate resolution. The two displays with the lowest resolution were clearly inferior. Predictors with higher resolution are of value but may trade off enhanced sensitivity to variable change (lower-resolution discrete state predictor) with smoother control action (higher-resolution continuous predictors). The research provides guidelines to the process-control industry regarding displays that can most improve operator performance.

  2. Virtual reality 3D headset based on DMD light modulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernacki, Bruce E.; Evans, Allan; Tang, Edward

    We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micro-mirror devices (DMD). Our approach leverages silicon micro mirrors offering 720p resolution displays in a small form-factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high resolution and low power consumption. Applications include night driving, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design is described in which light from the DMD is imaged to infinity and the user’s own eye lens forms a real image on the user’s retina.

  3. LANDSAT 4 band 6 data evaluation

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Previously experienced data collection problems were successfully resolved. A limited effort, directed at improved methods of display of TM Band 6 data, has concentrated on implementation of intensity hue and saturation displays using the Band 6 data to control hue. These displays tend to give the appearance of high resolution thermal data and make whole scene thermal interpretation easier by color coding thermal data in a manner that aids visual interpretation. More quantitative efforts were directed at utilizing the reflected bands to define land cover classes and then modifying the thermal displays using long wave optical properties associated with cover type.

  4. Method and Apparatus for Virtual Interactive Medical Imaging by Multiple Remotely-Located Users

    NASA Technical Reports Server (NTRS)

    Ross, Muriel D. (Inventor); Twombly, Ian Alexander (Inventor); Senger, Steven O. (Inventor)

    2003-01-01

    A virtual interactive imaging system allows the displaying of high-resolution, three-dimensional images of medical data to a user and allows the user to manipulate the images, including rotation of images in any of various axes. The system includes a mesh component that generates a mesh to represent a surface of an anatomical object, based on a set of data of the object, such as from a CT or MRI scan or the like. The mesh is generated so as to avoid tears, or holes, in the mesh, providing very high-quality representations of topographical features of the object, particularly at high- resolution. The system further includes a virtual surgical cutting tool that enables the user to simulate the removal of a piece or layer of a displayed object, such as a piece of skin or bone, view the interior of the object, manipulate the removed piece, and reattach the removed piece if desired. The system further includes a virtual collaborative clinic component, which allows the users of multiple, remotely-located computer systems to collaboratively and simultaneously view and manipulate the high-resolution, three-dimensional images of the object in real-time.

  5. Directional backlight liquid crystal autostereoscopic display: technical challenges, research progress, and prospect (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Fan, Hang; Li, Kunyang; Zhou, Yangui; Liang, Haowen; Wang, Jiahui; Zhou, Jianying

    2016-09-01

    Recent upsurge on virtual and augmented realities (VR and AR) has re-ignited the interest to the immerse display technology. The VR/AR technology based on stereoscopic display is believed in its early stage as glasses-free, or autostereoscopic display, will be ultimately adopted for the viewing convenience, visual comfort and for the multi-viewer purposes. On the other hand, autostereoscopic display has not yet received positive market response for the past years neither with stereoscopic displays using shutter or polarized glasses. We shall present the analysis on the real-world applications, rigid user demand, the drawbacks to the existing barrier- and lenticular lens-based LCD autostereoscopy. We shall emphasize the emerging autostereoscopic display, and notably on directional backlight LCD technology using a hybrid spatial- and temporal-control scenario. We report the numerical simulation of a display system using Monte-Carlo ray-tracing method with the human retina as the real image receiver. The system performance is optimized using newly developed figure of merit for system design. The reduced crosstalk in an autostereoscopic system, the enhanced display quality, including the high resolution received by the retina, the display homogeneity without Moiré- and defect-pattern, will be highlighted. Recent research progress including a novel scheme for diffraction-free backlight illumination, the expanded viewing zone for autostereoscopic display, and the novel Fresnel lens array to achieve a near perfect display in 2D/3D mode will be introduced. The experimental demonstration will be presented to the autostereoscopic display with the highest resolution, low crosstalk, Moiré- and defect- pattern free.

  6. An Attention-Information-Based Spatial Adaptation Framework for Browsing Videos via Mobile Devices

    NASA Astrophysics Data System (ADS)

    Li, Houqiang; Wang, Yi; Chen, Chang Wen

    2007-12-01

    With the growing popularity of personal digital assistant devices and smart phones, more and more consumers are becoming quite enthusiastic to appreciate videos via mobile devices. However, limited display size of the mobile devices has been imposing significant barriers for users to enjoy browsing high-resolution videos. In this paper, we present an attention-information-based spatial adaptation framework to address this problem. The whole framework includes two major parts: video content generation and video adaptation system. During video compression, the attention information in video sequences will be detected using an attention model and embedded into bitstreams with proposed supplement-enhanced information (SEI) structure. Furthermore, we also develop an innovative scheme to adaptively adjust quantization parameters in order to simultaneously improve the quality of overall encoding and the quality of transcoding the attention areas. When the high-resolution bitstream is transmitted to mobile users, a fast transcoding algorithm we developed earlier will be applied to generate a new bitstream for attention areas in frames. The new low-resolution bitstream containing mostly attention information, instead of the high-resolution one, will be sent to users for display on the mobile devices. Experimental results show that the proposed spatial adaptation scheme is able to improve both subjective and objective video qualities.

  7. Sunlight readable avionics displays

    NASA Astrophysics Data System (ADS)

    Visinski, Joseph R.

    1998-09-01

    The theme of the Cockpit Displays V Conference of 'Custom versus Consumer -- Grade Displays in Defense Applications' reflects the Raytheon Systems Company field emission display (FED) development effort. Raytheon chose to license commercial FED technology and subsequently participate in a commercial industry 'FED Alliance' to insert this technology into commercial and avionics defense applications. The unaffordability of custom military displays makes them an unfeasible choice to build a business upon. The major differences between consumer FEDs and those adapted for military/avionics installations are: (1) high brightness for sunlight visibility; (2) extended environmental range; (3) high resolution; (4) wider dimming range for sunlight to NVIS operation; (5) extended gray scales; (6) lifetime product support well beyond two year consumer market life. The transition to defense applications is further being accomplished via industry/government partnerships as the DARPA Technology Reinvestment Project (TRP) and BAA 97-31. FEDs combine cathode ray tube (CRT) and matrix addressed flat panel display technology, parts, manufacturing, and test equipment, plus open systems interfaces into a new display.

  8. Non-binary Colour Modulation for Display Device Based on Phase Change Materials.

    PubMed

    Ji, Hong-Kai; Tong, Hao; Qian, Hang; Hui, Ya-Juan; Liu, Nian; Yan, Peng; Miao, Xiang-Shui

    2016-12-19

    A reflective-type display device based on phase change materials is attractive because of its ultrafast response time and high resolution compared with a conventional display device. This paper proposes and demonstrates a unique display device in which multicolour changing can be achieved on a single device by the selective crystallization of double layer phase change materials. The optical contrast is optimized by the availability of a variety of film thicknesses of two phase change layers. The device exhibits a low sensitivity to the angle of incidence, which is important for display and colour consistency. The non-binary colour rendering on a single device is demonstrated for the first time using optical excitation. The device shows the potential for ultrafast display applications.

  9. Development of Plastic Substrate Technology for Active Matrix Liquid Crystal Displays Final Report CRADA No. TC-761-93

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carey, P.; Kamath, H.

    Raychem Corporation (RYC) and the Lawrence Livermore National Laboratory (LLNL) conducted a development program with the goal to make rugged, low-cost., high-resolution flat panel displays based on RYC's proprietary Nematic Curvilinear Aligned Phase (NCAP) liquid crystal and LLNL's patented processes for the formation and doping of polycrystalline silicon on low-temperature, flexible, plastic substrates.

  10. SVGA and XGA LCOS microdisplays for HMD applications

    NASA Astrophysics Data System (ADS)

    Bolotski, Michael; Alvelda, Phillip

    1999-07-01

    MicroDisplay liquid crystal on silicon (LCOS) display devices are based on a combination of technologies combined with the extreme integration capability of conventionally fabricated CMOS substrates. Two recent SVGA (800 X 600) pixel resolution designs were demonstrated based on 10 micron and 12.5-micron pixel pitch architectures. The resulting microdisplays measure approximately 10 mm and 12 mm in diagonal respectively. Further, an XGA (1024 X 768) resolution display fabricated with a 12.5-micron pixel pitch with a 16-mm diagonal was also demonstrated. Both the larger SVGA and the XGA design were based on the same 12.5-micron pixel-pitch design, demonstrating a quickly scalable design architecture for rapid prototyping life-cycles. All three microdisplay designs described above function in grayscale and high-performance Field-Sequential-Color (FSC) operating modes. The fast liquid crystal operating modes and new scalable high- performance pixel addressing architectures presented in this paper enable substantially improved color, contrast, and brightness while still satisfying the optical, packaging, and power requirements of portable commercial and defense applications including ultra-portable helmet, eyeglass, and heat-mounted systems. The entire suite of The MicroDisplay Corporation's technologies was devised to create a line of mixed-signal application-specific integrated circuits (ASIC) in single-chip display systems. Mixed-signal circuits can integrate computing, memory, and communication circuitry on the same substrate as the display drivers and pixel array for a multifunctional complete system-on-a-chip. For helmet and head-mounted displays this can include capabilities such as the incorporation of customized symbology and information storage directly on the display substrate. System-on-a-chip benefits also include reduced head supported weight requirements through the elimination of off-chip drive electronics.

  11. Multimission helicopter information display technology

    NASA Astrophysics Data System (ADS)

    Terry, William S.

    1995-06-01

    A new Operator display subsystem is being incorporated as part of the next generation United States Navy (USN) helicopter avionics system to be integrated into the Multi-Mission Helicopter (MMH) which will replace both the SH-60B and the SH- 60F in 2001. This subsystem exploits state-of-the-art technology for the display hardware, the display driver hardware, information presentation methodologies, and software architecture. The technologies to be base technologies have evolved during the development period and the solution has been modified to include current elements including high resolution AMLCD color displays that are sunlight readable, highly reliable, and significantly lighter that CRT technology, as well as Reduced Instruction Set Computer (RISC) based high-performance display generators that have only recently become feasible to implement in a military aircraft. This paper describes the overall subsystem architecture, some detail on the individual elements along with supporting rationale, the manner in which the display subsystem provides the necessary tools to significantly enhance the performance of the weapon system through the vital Operator-System Interface. Also addressed is a summary of the evolution of design leading to the current approach to MMH Operator displays and display processing as well as the growth path that the MMH display subsystem will most likely follow as additional technology evolution occurs.

  12. Advanced Three-Dimensional Display System

    NASA Technical Reports Server (NTRS)

    Geng, Jason

    2005-01-01

    A desktop-scale, computer-controlled display system, initially developed for NASA and now known as the VolumeViewer(TradeMark), generates three-dimensional (3D) images of 3D objects in a display volume. This system differs fundamentally from stereoscopic and holographic display systems: The images generated by this system are truly 3D in that they can be viewed from almost any angle, without the aid of special eyeglasses. It is possible to walk around the system while gazing at its display volume to see a displayed object from a changing perspective, and multiple observers standing at different positions around the display can view the object simultaneously from their individual perspectives, as though the displayed object were a real 3D object. At the time of writing this article, only partial information on the design and principle of operation of the system was available. It is known that the system includes a high-speed, silicon-backplane, ferroelectric-liquid-crystal spatial light modulator (SLM), multiple high-power lasers for projecting images in multiple colors, a rotating helix that serves as a moving screen for displaying voxels [volume cells or volume elements, in analogy to pixels (picture cells or picture elements) in two-dimensional (2D) images], and a host computer. The rotating helix and its motor drive are the only moving parts. Under control by the host computer, a stream of 2D image patterns is generated on the SLM and projected through optics onto the surface of the rotating helix. The system utilizes a parallel pixel/voxel-addressing scheme: All the pixels of the 2D pattern on the SLM are addressed simultaneously by laser beams. This parallel addressing scheme overcomes the difficulty of achieving both high resolution and a high frame rate in a raster scanning or serial addressing scheme. It has been reported that the structure of the system is simple and easy to build, that the optical design and alignment are not difficult, and that the system can be built by use of commercial off-the-shelf products. A prototype of the system displays an image of 1,024 by 768 by 170 (=133,693,440) voxels. In future designs, the resolution could be increased. The maximum number of voxels that can be generated depends upon the spatial resolution of SLM and the speed of rotation of the helix. For example, one could use an available SLM that has 1,024 by 1,024 pixels. Incidentally, this SLM is capable of operation at a switching speed of 300,000 frames per second. Implementation of full-color displays in future versions of the system would be straightforward: One could use three SLMs for red, green, and blue, respectively, and the colors of the voxels could be automatically controlled. An optically simpler alternative would be to use a single red/green/ blue light projector and synchronize the projection of each color with the generation of patterns for that color on a single SLM.

  13. Oil defect detection of electrowetting display

    NASA Astrophysics Data System (ADS)

    Chiang, Hou-Chi; Tsai, Yu-Hsiang; Yan, Yung-Jhe; Huang, Ting-Wei; Mang, Ou-Yang

    2015-08-01

    In recent years, transparent display is an emerging topic in display technologies. Apply in many fields just like mobile device, shopping or advertising window, and etc. Electrowetting Display (EWD) is one kind of potential transparent display technology advantages of high transmittance, fast response time, high contrast and rich color with pigment based oil system. In mass production process of Electrowetting Display, oil defects should be found by Automated Optical Inspection (AOI) detection system. It is useful in determination of panel defects for quality control. According to the research of our group, we proposed a mechanism of AOI detection system detecting the different kinds of oil defects. This mechanism can detect different kinds of oil defect caused by oil overflow or material deteriorated after oil coating or driving. We had experiment our mechanism with a 6-inch Electrowetting Display panel from ITRI, using an Epson V750 scanner with 1200 dpi resolution. Two AOI algorithms were developed, which were high speed method and high precision method. In high precision method, oil jumping or non-recovered can be detected successfully. This mechanism of AOI detection system can be used to evaluate the oil uniformity in EWD panel process. In the future, our AOI detection system can be used in quality control of panel manufacturing for mass production.

  14. Microscopy illumination engineering using a low-cost liquid crystal display.

    PubMed

    Guo, Kaikai; Bian, Zichao; Dong, Siyuan; Nanda, Pariksheet; Wang, Ying Min; Zheng, Guoan

    2015-02-01

    Illumination engineering is critical for obtaining high-resolution, high-quality images in microscope settings. In a typical microscope, the condenser lens provides sample illumination that is uniform and free from glare. The associated condenser diaphragm can be manually adjusted to obtain the optimal illumination numerical aperture. In this paper, we report a programmable condenser lens for active illumination control. In our prototype setup, we used a $15 liquid crystal display as a transparent spatial light modulator and placed it at the back focal plane of the condenser lens. By setting different binary patterns on the display, we can actively control the illumination and the spatial coherence of the microscope platform. We demonstrated the use of such a simple scheme for multimodal imaging, including bright-field microscopy, darkfield microscopy, phase-contrast microscopy, polarization microscopy, 3D tomographic imaging, and super-resolution Fourier ptychographic imaging. The reported illumination engineering scheme is cost-effective and compatible with most existing platforms. It enables a turnkey solution with high flexibility for researchers in various communities. From the engineering point-of-view, the reported illumination scheme may also provide new insights for the development of multimodal microscopy and Fourier ptychographic imaging.

  15. Synthetic vision display evaluation studies

    NASA Technical Reports Server (NTRS)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  16. Analysis on the 3D crosstalk in stereoscopic display

    NASA Astrophysics Data System (ADS)

    Choi, Hee-Jin

    2010-11-01

    Nowadays, with the rapid progresses in flat panel display (FPD) technologies, the three-dimensional (3D) display is now becoming a next mainstream of display market. Among the various 3D display techniques, the stereoscopic 3D display shows different left/right images for each eye of observer using special glasses and is the most popular 3D technique with the advantages of low price and high 3D resolution. However, current stereoscopic 3D displays suffer with the 3D crosstalk which means the interference between the left eye mage and right eye images since it degrades the quality of 3D image severely. In this paper, the meaning and causes of the 3D crosstalk in stereoscopic 3D display are introduced and the pre-proposed methods of 3D crosstalk measurement vision science are reviewed. Based on them The threshold of 3D crosstalk to realize a 3D display with no degradation is analyzed.

  17. Advanced Plasmonic Materials for Dynamic Color Display.

    PubMed

    Shao, Lei; Zhuo, Xiaolu; Wang, Jianfang

    2018-04-01

    Plasmonic structures exhibit promising applications in high-resolution and durable color generation. Research on advanced hybrid plasmonic materials that allow dynamically reconfigurable color control has developed rapidly in recent years. Some of these results may give rise to practically applicable reflective displays in living colors with high performance and low power consumption. They will attract broad interest from display markets, compared with static plasmonic color printing, for example, in applications such as digital signage, full-color electronic paper, and electronic device screens. In this progress report, the most promising recent examples of utilizing advanced plasmonic materials for the realization of dynamic color display are highlighted and put into perspective. The performances, advantages, and disadvantages of different technologies are discussed, with emphasis placed on both the potential and possible limitations of various hybrid materials for dynamic plasmonic color display. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Recent patents on electrophoretic displays and materials.

    PubMed

    Christophersen, Marc; Phlips, Bernard F

    2010-11-01

    Electrophoretic displays (EPDs) have made their way into consumer products. EPDs enable displays that offer the look and form of a printed page, often called "electronic paper". We will review recent apparatus and method patents for EPD devices and their fabrication. A brief introduction into the basic display operation and history of EPDs is given, while pointing out the technological challenges and difficulties for inventors. Recently, the majority of scientific publications and patenting activity has been directed to micro-segmented EPDs. These devices exhibit high optical reflectance and contrast, wide viewing angle, and high image resolution. Micro-segmented EPDs can also be integrated with flexible transistors technologies into flexible displays. Typical particles size ranges from 200 nm to 2 micrometer. Currently one very active area of patenting is the development of full-color EPDs. We summarize the recent patenting activity for EPDs and provide comments on perceiving factors driving intellectual property protection for EPD technologies.

  19. Dual-dimensional microscopy: real-time in vivo three-dimensional observation method using high-resolution light-field microscopy and light-field display.

    PubMed

    Kim, Jonghyun; Moon, Seokil; Jeong, Youngmo; Jang, Changwon; Kim, Youngmin; Lee, Byoungho

    2018-06-01

    Here, we present dual-dimensional microscopy that captures both two-dimensional (2-D) and light-field images of an in-vivo sample simultaneously, synthesizes an upsampled light-field image in real time, and visualizes it with a computational light-field display system in real time. Compared with conventional light-field microscopy, the additional 2-D image greatly enhances the lateral resolution at the native object plane up to the diffraction limit and compensates for the image degradation at the native object plane. The whole process from capturing to displaying is done in real time with the parallel computation algorithm, which enables the observation of the sample's three-dimensional (3-D) movement and direct interaction with the in-vivo sample. We demonstrate a real-time 3-D interactive experiment with Caenorhabditis elegans. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  20. Optical engineering challenges of the virtual retinal display

    NASA Astrophysics Data System (ADS)

    Kollin, Joel S.; Tidwell, Michael R.

    1995-08-01

    The Virtual Retinal Display (VRD) is a unique approach to developing a high-resolution head- mounted display currently under development at the University of Washington's Human Interface Technology (HIT) Laboratory. Rather than looking at a screen though a magnifier or optical relay system, the viewer of the VRD has a scanned beam of light enter the pupil of the eye and focused to a spot on the retina. This type of optical system is subject to different design constraints than a typical HMD. With the VRD it may be possible to realize higher resolution, greater color saturation, higher brightness and larger field-of-view than a traditional LCD or CRT screen-based system. In this paper the author will present the VRD approach and how it can provide these advantages. Issues to be resolved for the VRD to reach its full potential and some of the solutions developed at the HIT lab will also be discussed.

  1. 3D display considerations for rugged airborne environments

    NASA Astrophysics Data System (ADS)

    Barnidge, Tracy J.; Tchon, Joseph L.

    2015-05-01

    The KC-46 is the next generation, multi-role, aerial refueling tanker aircraft being developed by Boeing for the United States Air Force. Rockwell Collins has developed the Remote Vision System (RVS) that supports aerial refueling operations under a variety of conditions. The system utilizes large-area, high-resolution 3D displays linked with remote sensors to enhance the operator's visual acuity for precise aerial refueling control. This paper reviews the design considerations, trade-offs, and other factors related to the selection and ruggedization of the 3D display technology for this military application.

  2. Electrostatically actuatable light modulating device

    DOEpatents

    Koehler, Dale R.

    1991-01-01

    The electrostatically actuatable light modulator utilizes an opaque substrate plate patterned with an array of aperture cells, the cells comprised of physically positionable dielectric shutters and electrostatic actuators. With incorporation of a light source and a viewing screen, a projection display system is effected. Inclusion of a color filter array aligned with the aperture cells accomplishes a color display. The system is realized in terms of a silicon based manufacturing technology allowing fabrication of a high resolution capability in a physically small device which with the utilization of included magnification optics allows both large and small projection displays.

  3. EzMol: A Web Server Wizard for the Rapid Visualization and Image Production of Protein and Nucleic Acid Structures.

    PubMed

    Reynolds, Christopher R; Islam, Suhail A; Sternberg, Michael J E

    2018-01-31

    EzMol is a molecular visualization Web server in the form of a software wizard, located at http://www.sbg.bio.ic.ac.uk/ezmol/. It is designed for easy and rapid image manipulation and display of protein molecules, and is intended for users who need to quickly produce high-resolution images of protein molecules but do not have the time or inclination to use a software molecular visualization system. EzMol allows the upload of molecular structure files in PDB format to generate a Web page including a representation of the structure that the user can manipulate. EzMol provides intuitive options for chain display, adjusting the color/transparency of residues, side chains and protein surfaces, and for adding labels to residues. The final adjusted protein image can then be downloaded as a high-resolution image. There are a range of applications for rapid protein display, including the illustration of specific areas of a protein structure and the rapid prototyping of images. Copyright © 2018. Published by Elsevier Ltd.

  4. Display integration for ground combat vehicles

    NASA Astrophysics Data System (ADS)

    Busse, David J.

    1998-09-01

    The United States Army's requirement to employ high resolution target acquisition sensors and information warfare to increase its dominance over enemy forces has led to the need to integrate advanced display devices into ground combat vehicle crew stations. The Army's force structure require the integration of advanced displays on both existing and emerging ground combat vehicle systems. The fielding of second generation target acquisition sensors, color digital terrain maps and high volume digital command and control information networks on these platforms define display performance requirements. The greatest challenge facing the system integrator is the development and integration of advanced displays that meet operational, vehicle and human computer interface performance requirements for the ground combat vehicle fleet. The subject of this paper is to address those challenges: operational and vehicle performance, non-soldier centric crew station configurations, display performance limitations related to human computer interfaces and vehicle physical environments, display technology limitations and the Department of Defense (DOD) acquisition reform initiatives. How the ground combat vehicle Program Manager and system integrator are addressing these challenges are discussed through the integration of displays on fielded, current and future close combat vehicle applications.

  5. SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knewtson, T; Pokhrel, S; University of Tennessee Health Science Center, Memphis, TN

    2016-06-15

    Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. Themore » fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.« less

  6. Spatial Resolution, Grayscale, and Error Diffusion Trade-offs: Impact on Display System Design

    NASA Technical Reports Server (NTRS)

    Gille, Jennifer L. (Principal Investigator)

    1996-01-01

    We examine technology trade-offs related to grayscale resolution, spatial resolution, and error diffusion for tessellated display systems. We present new empirical results from our psychophysical study of these trade-offs and compare them to the predictions of a model of human vision.

  7. Novel low-cost 2D/3D switchable autostereoscopic system for notebook computers and other portable devices

    NASA Astrophysics Data System (ADS)

    Eichenlaub, Jesse B.

    1995-03-01

    Mounting a lenticular lens in front of a flat panel display is a well known, inexpensive, and easy way to create an autostereoscopic system. Such a lens produces half resolution 3D images because half the pixels on the LCD are seen by the left eye and half by the right eye. This may be acceptable for graphics, but it makes full resolution text, as displayed by common software, nearly unreadable. Very fine alignment tolerances normally preclude the possibility of removing and replacing the lens in order to switch between 2D and 3D applications. Lenticular lens based displays are therefore limited to use as dedicated 3D devices. DTI has devised a technique which removes this limitation, allowing switching between full resolution 2D and half resolution 3D imaging modes. A second element, in the form of a concave lenticular lens array whose shape is exactly the negative of the first lens, is mounted on a hinge so that it can be swung down over the first lens array. When so positioned the two lenses cancel optically, allowing the user to see full resolution 2D for text or numerical applications. The two lenses, having complementary shapes, naturally tend to nestle together and snap into perfect alignment when pressed together--thus obviating any need for user operated alignment mechanisms. This system represents an ideal solution for laptop and notebook computer applications. It was devised to meet the stringent requirements of a laptop computer manufacturer including very compact size, very low cost, little impact on existing manufacturing or assembly procedures, and compatibility with existing full resolution 2D text- oriented software as well as 3D graphics. Similar requirements apply to high and electronic calculators, several models of which now use LCDs for the display of graphics.

  8. A compact high-definition low-cost digital stereoscopic video camera for rapid robotic surgery development.

    PubMed

    Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C

    2012-01-01

    Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.

  9. NPS assessment of color medical displays using a monochromatic CCD camera

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2012-02-01

    This paper presents an approach to Noise Power Spectrum (NPS) assessment of color medical displays without using an expensive imaging colorimeter. The R, G and B color uniform patterns were shown on the display under study and the images were taken using a high resolution monochromatic camera. A colorimeter was used to calibrate the camera images. Synthetic intensity images were formed by the weighted sum of the R, G, B and the dark screen images. Finally the NPS analysis was conducted on the synthetic images. The proposed method replaces an expensive imaging colorimeter for NPS evaluation, which also suggests a potential solution for routine color medical display QA/QC in the clinical area, especially when imaging of display devices is desired.

  10. NPS assessment of color medical image displays using a monochromatic CCD camera

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2012-10-01

    This paper presents an approach to Noise Power Spectrum (NPS) assessment of color medical displays without using an expensive imaging colorimeter. The R, G and B color uniform patterns were shown on the display under study and the images were taken using a high resolution monochromatic camera. A colorimeter was used to calibrate the camera images. Synthetic intensity images were formed by the weighted sum of the R, G, B and the dark screen images. Finally the NPS analysis was conducted on the synthetic images. The proposed method replaces an expensive imaging colorimeter for NPS evaluation, which also suggests a potential solution for routine color medical display QA/QC in the clinical area, especially when imaging of display devices is desired

  11. Efficient fabrication method of nano-grating for 3D holographic display with full parallax views.

    PubMed

    Wan, Wenqiang; Qiao, Wen; Huang, Wenbin; Zhu, Ming; Fang, Zongbao; Pu, Donglin; Ye, Yan; Liu, Yanhua; Chen, Linsen

    2016-03-21

    Without any special glasses, multiview 3D displays based on the diffractive optics can present high resolution, full-parallax 3D images in an ultra-wide viewing angle. The enabling optical component, namely the phase plate, can produce arbitrarily distributed view zones by carefully designing the orientation and the period of each nano-grating pixel. However, such 3D display screen is restricted to a limited size due to the time-consuming fabricating process of nano-gratings on the phase plate. In this paper, we proposed and developed a lithography system that can fabricate the phase plate efficiently. Here we made two phase plates with full nano-grating pixel coverage at a speed of 20 mm2/mins, a 500 fold increment in the efficiency when compared to the method of E-beam lithography. One 2.5-inch phase plate generated 9-view 3D images with horizontal-parallax, while the other 6-inch phase plate produced 64-view 3D images with full-parallax. The angular divergence in horizontal axis and vertical axis was 1.5 degrees, and 1.25 degrees, respectively, slightly larger than the simulated value of 1.2 degrees by Finite Difference Time Domain (FDTD). The intensity variation was less than 10% for each viewpoint, in consistency with the simulation results. On top of each phase plate, a high-resolution binary masking pattern containing amplitude information of all viewing zone was well aligned. We achieved a resolution of 400 pixels/inch and a viewing angle of 40 degrees for 9-view 3D images with horizontal parallax. In another prototype, the resolution of each view was 160 pixels/inch and the view angle was 50 degrees for 64-view 3D images with full parallax. As demonstrated in the experiments, the homemade lithography system provided the key fabricating technology for multiview 3D holographic display.

  12. Development of scanning holographic display using MEMS SLM

    NASA Astrophysics Data System (ADS)

    Takaki, Yasuhiro

    2016-10-01

    Holography is an ideal three-dimensional (3D) display technique, because it produces 3D images that naturally satisfy human 3D perception including physiological and psychological factors. However, its electronic implementation is quite challenging because ultra-high resolution is required for display devices to provide sufficient screen size and viewing zone. We have developed holographic display techniques to enlarge the screen size and the viewing zone by use of microelectromechanical systems spatial light modulators (MEMS-SLMs). Because MEMS-SLMs can generate hologram patterns at a high frame rate, the time-multiplexing technique is utilized to virtually increase the resolution. Three kinds of scanning systems have been combined with MEMS-SLMs; the screen scanning system, the viewing-zone scanning system, and the 360-degree scanning system. The screen scanning system reduces the hologram size to enlarge the viewing zone and the reduced hologram patterns are scanned on the screen to increase the screen size: the color display system with a screen size of 6.2 in. and a viewing zone angle of 11° was demonstrated. The viewing-zone scanning system increases the screen size and the reduced viewing zone is scanned to enlarge the viewing zone: a screen size of 2.0 in. and a viewing zone angle of 40° were achieved. The two-channel system increased the screen size to 7.4 in. The 360-degree scanning increases the screen size and the reduced viewing zone is scanned circularly: the display system having a flat screen with a diameter of 100 mm was demonstrated, which generates 3D images viewed from any direction around the flat screen.

  13. Dynamic plasmonic colour display

    NASA Astrophysics Data System (ADS)

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-02-01

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.

  14. Dynamic plasmonic colour display.

    PubMed

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-02-24

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.

  15. Dynamic plasmonic colour display

    PubMed Central

    Duan, Xiaoyang; Kamin, Simon; Liu, Na

    2017-01-01

    Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications. PMID:28232722

  16. High-resolution LCOS microdisplay with sub-kHz frame rate for high performance, high precision 3D sensor

    NASA Astrophysics Data System (ADS)

    Lazarev, Grigory; Bonifer, Stefanie; Engel, Philip; Höhne, Daniel; Notni, Gunther

    2017-06-01

    We report about the implementation of the liquid crystal on silicon (LCOS) microdisplay with 1920 by 1080 resolution and 720 Hz frame rate. The driving solution is FPGA-based. The input signal is converted from the ultrahigh-resolution HDMI 2.0 signal into HD frames, which follow with the specified 720 Hz frame rate. Alternatively the signal is generated directly on the FPGA with built-in pattern generator. The display is showing switching times below 1.5 ms for the selected working temperature. The bit depth of the addressed image achieves 8 bit within each frame. The microdisplay is used in the fringe projection-based 3D sensing system, implemented by Fraunhofer IOF.

  17. High-performance 4x4-inch AMLCD for avionic applications

    NASA Astrophysics Data System (ADS)

    Syroid, Daniel D.; Hansen, Glenn A.; Boling, Ed

    1996-05-01

    There is a need for high performance flat panel displays to replace and upgrade the electromechanical flight indicators and CRT based displays used in the cockpits of many older aircraft that are in active service today. The need for replacement of these older generation instruments is well known in the industry and was discussed in a previous paper by Duane Grave of Rockwell Collins. Furthermore, because of the limited activity in new aircraft development today, the need to upgrade existing aircraft avionics is accelerating. Many of the electromechanical instruments currently provide flight indications to the pilot and include horizontal situation (HSI) and attitude director indicators (ADI). These instruments are used on both military and commercial aircraft. The indicators are typically housed in a 5ATI case that slides into a 5 inch square opening in the cockpit. Image Quest has developed a 4 by 4 inch active area, flight quality, high resolution, full color, high luminance, wide temperature range display module based on active matrix liquid crystal display (AMLCD) technology that has excellent contrast in full sunlight. The display module is well suited for use in electronic instruments to replace or upgrade the electro-mechanical 5ATI flight indicators. THe AMLCD based display offers greatly improved display format flexibility, operating reliability and display contrast in all ambient lighting conditions as well as significant short and long term cost of ownership advantages.

  18. Continuously Tunable, Polarization Controlled, Colour Palette Produced from Nanoscale Plasmonic Pixels.

    PubMed

    Balaur, Eugeniu; Sadatnajafi, Catherine; Kou, Shan Shan; Lin, Jiao; Abbey, Brian

    2016-06-17

    Colour filters based on nano-apertures in thin metallic films have been widely studied due to their extraordinary optical transmission and small size. These properties make them prime candidates for use in high-resolution colour displays and high accuracy bio-sensors. The inclusion of polarization sensitive plasmonic features in such devices allow additional control over the electromagnetic field distribution, critical for investigations of polarization induced phenomena. Here we demonstrate that cross-shaped nano-apertures can be used for polarization controlled color tuning in the visible range and apply fundamental theoretical models to interpret key features of the transmitted spectrum. Full color transmission was achieved by fine-tuning the periodicity of the apertures, whilst keeping the geometry of individual apertures constant. We demonstrate this effect for both transverse electric and magnetic fields. Furthermore we have been able to demonstrate the same polarization sensitivity even for nano-size, sub-wavelength sets of arrays, which is paramount for ultra-high resolution compact colour displays.

  19. Continuously Tunable, Polarization Controlled, Colour Palette Produced from Nanoscale Plasmonic Pixels

    PubMed Central

    Balaur, Eugeniu; Sadatnajafi, Catherine; Kou, Shan Shan; Lin, Jiao; Abbey, Brian

    2016-01-01

    Colour filters based on nano-apertures in thin metallic films have been widely studied due to their extraordinary optical transmission and small size. These properties make them prime candidates for use in high-resolution colour displays and high accuracy bio-sensors. The inclusion of polarization sensitive plasmonic features in such devices allow additional control over the electromagnetic field distribution, critical for investigations of polarization induced phenomena. Here we demonstrate that cross-shaped nano-apertures can be used for polarization controlled color tuning in the visible range and apply fundamental theoretical models to interpret key features of the transmitted spectrum. Full color transmission was achieved by fine-tuning the periodicity of the apertures, whilst keeping the geometry of individual apertures constant. We demonstrate this effect for both transverse electric and magnetic fields. Furthermore we have been able to demonstrate the same polarization sensitivity even for nano-size, sub-wavelength sets of arrays, which is paramount for ultra-high resolution compact colour displays. PMID:27312072

  20. AMOEBA clustering revisited. [cluster analysis, classification, and image display program

    NASA Technical Reports Server (NTRS)

    Bryant, Jack

    1990-01-01

    A description of the clustering, classification, and image display program AMOEBA is presented. Using a difficult high resolution aircraft-acquired MSS image, the steps the program takes in forming clusters are traced. A number of new features are described here for the first time. Usage of the program is discussed. The theoretical foundation (the underlying mathematical model) is briefly presented. The program can handle images of any size and dimensionality.

  1. Performance considerations for high-definition head-mounted displays

    NASA Technical Reports Server (NTRS)

    Edwards, Oliver J.; Larimer, James; Gille, Jennifer

    1992-01-01

    Design image-optimization for helmet-mounted displays (HMDs) for military systems is presently discussed within the framework of a systems-engineering approach that encompasses (1) a description of natural targets in the field; (2) the characteristics of human visual perception; and (3) device specifications that directly relate to these ecological and human-factors parameters. Attention is given to target size and contrast and the relationship of the modulation transfer function to image resolution.

  2. The compatibility of consumer DLP projectors with time-sequential stereoscopic 3D visualisation

    NASA Astrophysics Data System (ADS)

    Woods, Andrew J.; Rourke, Tegan

    2007-02-01

    A range of advertised "Stereo-Ready" DLP projectors are now available in the market which allow high-quality flickerfree stereoscopic 3D visualization using the time-sequential stereoscopic display method. The ability to use a single projector for stereoscopic viewing offers a range of advantages, including extremely good stereoscopic alignment, and in some cases, portability. It has also recently become known that some consumer DLP projectors can be used for timesequential stereoscopic visualization, however it was not well understood which projectors are compatible and incompatible, what display modes (frequency and resolution) are compatible, and what stereoscopic display quality attributes are important. We conducted a study to test a wide range of projectors for stereoscopic compatibility. This paper reports on the testing of 45 consumer DLP projectors of widely different specifications (brand, resolution, brightness, etc). The projectors were tested for stereoscopic compatibility with various video formats (PAL, NTSC, 480P, 576P, and various VGA resolutions) and video input connections (composite, SVideo, component, and VGA). Fifteen projectors were found to work well at up to 85Hz stereo in VGA mode. Twenty three projectors would work at 60Hz stereo in VGA mode.

  3. National Laboratory for Advanced Scientific Visualization at UNAM - Mexico

    NASA Astrophysics Data System (ADS)

    Manea, Marina; Constantin Manea, Vlad; Varela, Alfredo

    2016-04-01

    In 2015, the National Autonomous University of Mexico (UNAM) joined the family of Universities and Research Centers where advanced visualization and computing plays a key role to promote and advance missions in research, education, community outreach, as well as business-oriented consulting. This initiative provides access to a great variety of advanced hardware and software resources and offers a range of consulting services that spans a variety of areas related to scientific visualization, among which are: neuroanatomy, embryonic development, genome related studies, geosciences, geography, physics and mathematics related disciplines. The National Laboratory for Advanced Scientific Visualization delivers services through three main infrastructure environments: the 3D fully immersive display system Cave, the high resolution parallel visualization system Powerwall, the high resolution spherical displays Earth Simulator. The entire visualization infrastructure is interconnected to a high-performance-computing-cluster (HPCC) called ADA in honor to Ada Lovelace, considered to be the first computer programmer. The Cave is an extra large 3.6m wide room with projected images on the front, left and right, as well as floor walls. Specialized crystal eyes LCD-shutter glasses provide a strong stereo depth perception, and a variety of tracking devices allow software to track the position of a user's hand, head and wand. The Powerwall is designed to bring large amounts of complex data together through parallel computing for team interaction and collaboration. This system is composed by 24 (6x4) high-resolution ultra-thin (2 mm) bezel monitors connected to a high-performance GPU cluster. The Earth Simulator is a large (60") high-resolution spherical display used for global-scale data visualization like geophysical, meteorological, climate and ecology data. The HPCC-ADA, is a 1000+ computing core system, which offers parallel computing resources to applications that requires large quantity of memory as well as large and fast parallel storage systems. The entire system temperature is controlled by an energy and space efficient cooling solution, based on large rear door liquid cooled heat exchangers. This state-of-the-art infrastructure will boost research activities in the region, offer a powerful scientific tool for teaching at undergraduate and graduate levels, and enhance association and cooperation with business-oriented organizations.

  4. Tactile Feedback Display with Spatial and Temporal Resolutions

    PubMed Central

    Vishniakou, Siarhei; Lewis, Brian W.; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-01-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications. PMID:23982053

  5. Tactile feedback display with spatial and temporal resolutions.

    PubMed

    Vishniakou, Siarhei; Lewis, Brian W; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-01-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications.

  6. Tactile Feedback Display with Spatial and Temporal Resolutions

    NASA Astrophysics Data System (ADS)

    Vishniakou, Siarhei; Lewis, Brian W.; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-08-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications.

  7. Investigation of imaging and flight guidance concepts for rotorcraft zero visibility approach and landing

    NASA Technical Reports Server (NTRS)

    Mckeown, W. L.

    1984-01-01

    A simulation experiment to explore the use of an augmented pictorial display to approach and land a helicopter in zero visibility conditions was conducted in a fixed base simulator. A literature search was also conducted to determine related work. A display was developed and pilot in-the-loop evaluations were conducted. The pictorial display was a simulated, high resolution radar image, augmented with various parameters to improve distance and motion cues. Approaches and landings were accomplished, but with higher workloads and less accuracy than necessary for a practical system. Recommendations are provided for display improvements and a follow on simulation study in a moving based simulator.

  8. Electronic data generation and display system

    NASA Technical Reports Server (NTRS)

    Wetekamm, Jules

    1988-01-01

    The Electronic Data Generation and Display System (EDGADS) is a field tested paperless technical manual system. The authoring provides subject matter experts the option of developing procedureware from digital or hardcopy inputs of technical information from text, graphics, pictures, and recorded media (video, audio, etc.). The display system provides multi-window presentations of graphics, pictures, animations, and action sequences with text and audio overlays on high resolution color CRT and monochrome portable displays. The database management system allows direct access via hierarchical menus, keyword name, ID number, voice command or touch of a screen pictoral of the item (ICON). It contains operations and maintenance technical information at three levels of intelligence for a total system.

  9. Fiber optic cable-based high-resolution, long-distance VGA extenders

    NASA Astrophysics Data System (ADS)

    Rhee, Jin-Geun; Lee, Iksoo; Kim, Heejoon; Kim, Sungjoon; Koh, Yeon-Wan; Kim, Hoik; Lim, Jiseok; Kim, Chur; Kim, Jungwon

    2013-02-01

    Remote transfer of high-resolution video information finds more applications in detached display applications for large facilities such as theaters, sports complex, airports, and security facilities. Active optical cables (AOCs) provide a promising approach for enhancing both the transmittable resolution and distance that standard copper-based cables cannot reach. In addition to the standard digital formats such as HDMI, the high-resolution, long-distance transfer of VGA format signals is important for applications where high-resolution analog video ports should be also supported, such as military/defense applications and high-resolution video camera links. In this presentation we present the development of a compressionless, high-resolution (up to WUXGA, 1920x1200), long-distance (up to 2 km) VGA extenders based on serialized technique. We employed asynchronous serial transmission and clock regeneration techniques, which enables lower cost implementation of VGA extenders by removing the necessity for clock transmission and large memory at the receiver. Two 3.125-Gbps transceivers are used in parallel to meet the required maximum video data rate of 6.25 Gbps. As the data are transmitted asynchronously, 24-bit pixel clock time stamp is employed to regenerate video pixel clock accurately at the receiver side. In parallel to the video information, stereo audio and RS-232 control signals are transmitted as well.

  10. Display dimensionality and conflict geometry effects on maneuver preferences for resolving in-flight conflicts.

    PubMed

    Thomas, Lisa C; Wickens, Christopher D

    2008-08-01

    Two experiments explored the effects of display dimensionality, conflict geometry, and time pressure on pilot maneuvering preferences for resolving en route conflicts. With the presence of a cockpit display of traffic information (CDTI) that provides graphical airspace information, pilots can use a variety of conflict resolution maneuvers in response to how they perceive the conflict. Inconsistent preference findings from previous research on conflict resolution using CDTIs may be attributable to inherent ambiguities in 3-D perspective displays and/or a limited range of conflict geometries. Pilots resolved predicted conflicts using CDTIs with three levels of display dimensionality; the first had two 2-D orthogonal views, the second depicted the airspace in two alternating 3-D perspective views, and the third had a pilot-controlled swiveling viewpoint. Pilots demonstrated the same preferences that have been observed in previous research for vertical over lateral maneuvers in low workload and climbs over descents for level-flight conflicts. With increasing workload the two 3-D perspective displays, but not the 2-D displays, resulted in an increased preference for lateral over vertical maneuvers. Increased time pressure resulted in increased vertical maneuvers, an effect again limited to the two 3-D perspective displays. Resolution preferences were more affected by workload and time pressure when the 3-D perspective displays were used, as compared with the 2-D displays, although overall preferences were milder than in previous studies. Investigating maneuver preferences using the strategic flight planning paradigm employed in this study may be the key to better ensure pilot acceptance of computer-generated resolution maneuvers.

  11. The Effects of Actual Human Size Display and Stereoscopic Presentation on Users' Sense of Being Together with and of Psychological Immersion in a Virtual Character

    PubMed Central

    Ahn, Dohyun; Seo, Youngnam; Kim, Minkyung; Kwon, Joung Huem; Jung, Younbo; Ahn, Jungsun

    2014-01-01

    Abstract This study examined the role of display size and mode in increasing users' sense of being together with and of their psychological immersion in a virtual character. Using a high-resolution three-dimensional virtual character, this study employed a 2×2 (stereoscopic mode vs. monoscopic mode×actual human size vs. small size display) factorial design in an experiment with 144 participants randomly assigned to each condition. Findings showed that stereoscopic mode had a significant effect on both users' sense of being together and psychological immersion. However, display size affected only the sense of being together. Furthermore, display size was not found to moderate the effect of stereoscopic mode. PMID:24606057

  12. Advantages and difficulties of implementation of flat-panel multimedia monitoring system in a surgical MRI suite

    NASA Astrophysics Data System (ADS)

    Deckard, Michael; Ratib, Osman M.; Rubino, Gregory

    2002-05-01

    Our project was to design and implement a ceiling-mounted multi monitor display unit for use in a high-field MRI surgical suite. The system is designed to simultaneously display images/data from four different digital and/or analog sources with: minimal interference from the adjacent high magnetic field, minimal signal-to-noise/artifact contribution to the MRI images and compliance with codes and regulations for the sterile neuro-surgical environment. Provisions were also made to accommodate the importing and exporting of video information via PACS and remote processing/display for clinical and education uses. Commercial fiber optic receivers/transmitters were implemented along with supporting video processing and distribution equipment to solve the video communication problem. A new generation of high-resolution color flat panel displays was selected for the project. A custom-made monitor mount and in-suite electronics enclosure was designed and constructed at UCLA. Difficulties with implementing an isolated AC power system are discussed and a work-around solution presented.

  13. Intensive care unit referring physician usage of PACS workstation functions based on disease categories

    NASA Astrophysics Data System (ADS)

    Horii, Steven C.; Kundel, Harold L.; Shile, Peter E.; Carey, Bruce; Seshadri, Sridhar B.; Feingold, Eric R.

    1994-05-01

    As part of a study of the use of a PACS workstation compared to film in a Medical Intensive Care Unit, logs of workstation activity were maintained. The software for the workstation kept track of the type of user (i.e., intern, resident, fellow, or attending physician) and also of the workstation image manipulation functions used. The functions logged were: no operation, brightness/contrast adjustment, invert video, zoom, and high resolution display (this last function resulted in the display of the full 2 K X 2 K image rather than the usual subsampled 1 K X 1 K image. Associated data collection allows us to obtain the diagnostic category of the examination being viewed (e.g., location of tubes and lines, rule out: pneumonia, congestive heart failure, pneumothorax, and pleural effusion). The diagnostic categories and user type were then correlated with the use of workstation functions during viewing of images. In general, there was an inverse relationship between the level of training and the number of workstation uses. About two-thirds of the time, there was no image manipulation operation performed. Adjustment of brightness/contrast had the highest percentage of use overall, followed by zoom, video invert, and high resolution display.

  14. Efficient green lasers for high-resolution scanning micro-projector displays

    NASA Astrophysics Data System (ADS)

    Bhatia, Vikram; Bauco, Anthony S.; Oubei, Hassan M.; Loeber, David A. S.

    2010-02-01

    Laser-based projectors are gaining increased acceptance in mobile device market due to their low power consumption, superior image quality and small size. The basic configuration of such micro-projectors is a miniature mirror that creates an image by raster scanning the collinear red, blue and green laser beams that are individually modulated on a pixel-bypixel basis. The image resolution of these displays can be limited by the modulation bandwidth of the laser sources, and the modulation speed of the green laser has been one of the key limitations in the development of these displays. We will discuss how this limitation is fundamental to the architecture of many laser designs and then present a green laser configuration which overcomes these difficulties. In this green laser architecture infra-red light from a distributed Bragg-reflector (DBR) laser diode undergoes conversion to green light in a waveguided second harmonic generator (SHG) crystal. The direct doubling in a single pass through the SHG crystal allows the device to operate at the large modulation bandwidth of the DBR laser. We demonstrate that the resultant product has a small footprint (<0.7 cc envelope volume), high efficiency (>9% electrical-to-optical conversion) and large modulation bandwidth (>100 MHz).

  15. Cholesteric Liquid Crystal Based Reflex Color Reflective Displays

    NASA Astrophysics Data System (ADS)

    Khan, Asad

    2012-02-01

    Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer products and related markets. This is a development that spans a wide space of highly technical development and fundamental science to products and commercialization to enable the entry of the technology into consumer markets.

  16. Real-time bilinear rotation decoupling in absorptive mode J-spectroscopy: Detecting low-intensity metabolite peak close to high-intensity metabolite peak with convenience.

    PubMed

    Verma, Ajay; Baishya, Bikash

    2016-05-01

    "Pure shift" NMR spectra display singlet peak per chemical site. Thus, high resolution is offered at the cost of valuable J-coupling information. In the present work, real-time BIRD (BIlinear Rotation Decoupling) is applied to the absorptive-mode 2D J-spectroscopy to provide pure shift spectrum in the direct dimension and J-coupling information in the indirect dimension. Quite often in metabolomics, proton NMR spectra from complex bio-fluids display tremendous signal overlap. Although conventional J-spectroscopy in principle overcomes this problem by separating the multiplet information from chemical shift information, however, only magnitude mode of the experiment is practical, sacrificing much of the potential high resolution that could be achieved. Few J-spectroscopy methods have been reported so far that produce high-resolution pure shift spectrum along with J-coupling information for crowded spectral regions. In the present work, high-quality J-resolved spectrum from important metabolomic mixture such as tissue extract from rat cortex is demonstrated. Many low-intensity metabolite peaks which are obscured by the broad dispersive tails from high-intensity metabolite peaks in regular magnitude mode J-spectrum can be clearly identified in real-time BIRD J-resolved spectrum. The general practice of removing such spectral overlap is tedious and time-consuming as it involves repeated sample preparation to change the pH of the tissue extract sample and subsequent spectra recording. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Real-time bilinear rotation decoupling in absorptive mode J-spectroscopy: Detecting low-intensity metabolite peak close to high-intensity metabolite peak with convenience

    NASA Astrophysics Data System (ADS)

    Verma, Ajay; Baishya, Bikash

    2016-05-01

    ;Pure shift; NMR spectra display singlet peak per chemical site. Thus, high resolution is offered at the cost of valuable J-coupling information. In the present work, real-time BIRD (BIlinear Rotation Decoupling) is applied to the absorptive-mode 2D J-spectroscopy to provide pure shift spectrum in the direct dimension and J-coupling information in the indirect dimension. Quite often in metabolomics, proton NMR spectra from complex bio-fluids display tremendous signal overlap. Although conventional J-spectroscopy in principle overcomes this problem by separating the multiplet information from chemical shift information, however, only magnitude mode of the experiment is practical, sacrificing much of the potential high resolution that could be achieved. Few J-spectroscopy methods have been reported so far that produce high-resolution pure shift spectrum along with J-coupling information for crowded spectral regions. In the present work, high-quality J-resolved spectrum from important metabolomic mixture such as tissue extract from rat cortex is demonstrated. Many low-intensity metabolite peaks which are obscured by the broad dispersive tails from high-intensity metabolite peaks in regular magnitude mode J-spectrum can be clearly identified in real-time BIRD J-resolved spectrum. The general practice of removing such spectral overlap is tedious and time-consuming as it involves repeated sample preparation to change the pH of the tissue extract sample and subsequent spectra recording.

  18. Using ARINC 818 Avionics Digital Video Bus (ADVB) for military displays

    NASA Astrophysics Data System (ADS)

    Alexander, Jon; Keller, Tim

    2007-04-01

    ARINC 818 Avionics Digital Video Bus (ADVB) is a new digital video interface and protocol standard developed especially for high bandwidth uncompressed digital video. The first draft of this standard, released in January of 2007, has been advanced by ARINC and the aerospace community to meet the acute needs of commercial aviation for higher performance digital video. This paper analyzes ARINC 818 for use in military display systems found in avionics, helicopters, and ground vehicles. The flexibility of ARINC 818 for the diverse resolutions, grayscales, pixel formats, and frame rates of military displays is analyzed as well as the suitability of ARINC 818 to support requirements for military video systems including bandwidth, latency, and reliability. Implementation issues relevant to military displays are presented.

  19. Microchannel plate for high-efficiency field emission display

    NASA Astrophysics Data System (ADS)

    Yi, Whikun; Jin, Sunghwan; Jeong, Taewon; Lee, Jeonghee; Yu, SeGi; Choi, Yongsoo; Kim, J. M.

    2000-09-01

    The efficiency of a field emission display was improved significantly with a newly developed microchannel plate. The key features of this unit and its fabrication are summarized as follows: (a) bulk alumina is used as a substrate material, (b) channel location is defined by a programed-hole puncher, and (c) thin film deposition is conducted by electroless plating followed by a sol-gel process. With the microchannel plate between the cathode and the anode of a field emission display, the brightness of luminescent light increases three- to fourfold by electron multiplication through an array of pores in the device. In addition, the fabricated microchannel plate prevents spreading of electrons emitted from the cathode tips, thus improving both display resolution and picture quality.

  20. Feasibility of High-Resolution Pulse-Echo Techniques for Automobile Tire Inspection

    DOT National Transportation Integrated Search

    1973-06-01

    The report presents ultrasonic A-scan reflection oscillograms and B-scan one-dimensional scanning displays for small sections of automobile tires, and for tire-like rubber and cord composite structures, using impulse excitation of 1-MHz and 5-MHz tra...

  1. Fluorescence-guided tumor visualization using a custom designed NIR attachment to a surgical microscope for high sensitivity imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kittle, David S.; Patil, Chirag G.; Mamelak, Adam; Hansen, Stacey; Perry, Jeff; Ishak, Laura; Black, Keith L.; Butte, Pramod V.

    2016-03-01

    Current surgical microscopes are limited in sensitivity for NIR fluorescence. Recent developments in tumor markers attached with NIR dyes require newer, more sensitive imaging systems with high resolution to guide surgical resection. We report on a small, single camera solution enabling advanced image processing opportunities previously unavailable for ultra-high sensitivity imaging of these agents. The system captures both visible reflectance and NIR fluorescence at 300 fps while displaying full HD resolution video at 60 fps. The camera head has been designed to easily mount onto the Zeiss Pentero microscope head for seamless integration into surgical procedures.

  2. Image quality evaluation for smart-phone displays at lighting levels of indoor and outdoor conditions

    NASA Astrophysics Data System (ADS)

    Gong, Rui; Xu, Haisong; Wang, Binyu; Luo, Ming Ronnier

    2012-08-01

    The image quality of two active matrix organic light emitting diode (AMOLED) smart-phone displays and two in-plane switching (IPS) ones was visually assessed at two levels of ambient lighting conditions corresponding to indoor and outdoor applications, respectively. Naturalness, colorfulness, brightness, contrast, sharpness, and overall image quality were evaluated via psychophysical experiment by categorical judgment method using test images selected from different application categories. The experimental results show that the AMOLED displays perform better on colorfulness because of their wide color gamut, while the high pixel resolution and high peak luminance of the IPS panels help the perception of brightness, contrast, and sharpness. Further statistical analysis of ANOVA indicates that ambient lighting levels have significant influences on the attributes of brightness and contrast.

  3. Infrared Imagery of Shuttle (IRIS). Task 1, summary report

    NASA Technical Reports Server (NTRS)

    Chocol, C. J.

    1977-01-01

    The feasibility of remote, high-resolution infrared imagery of the Shuttle Orbiter lower surface during entry to obtain accurate measurements of aerodynamic heat transfer was demonstrated. Using available technology, such images can be taken from an existing aircraft/telescope system (the C141 AIRO) with minimum modification or addition of systems. Images with a spatial resolution of 1 m or better and a temperature resolution of 2.5% between temperatures of 800 and 1900 K can be obtained. Data reconstruction techniques can provide a geometrically and radiometrically corrected array on addressable magnetic tape ready for display by NASA.

  4. The Development of a Scanning Soft X-Ray Microscope.

    NASA Astrophysics Data System (ADS)

    Rarback, Harvey Miles

    We have developed a scanning soft X-ray microscope, which can be used to image natural biological specimens at high resolution and with less damage than electron microscopy. The microscope focuses a monochromatic beam of synchrotron radiation to a nearly diffraction limited spot with the aid of a high resolution Fresnel zone plate, specially fabricated for us at the IBM Watson Research Center. The specimen at one atmosphere is mechanically scanned through the spot and the transmitted radiation is efficiently detected with a flow proportional counter. A computer forms a realtime transmission image of the specimen which is displayed on a color monitor. Our first generation optics have produced images of natural wet specimens at a resolution of 300 nm.

  5. Volumetric 3D Display System with Static Screen

    NASA Technical Reports Server (NTRS)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous approaches, so there is no image jitter, and has an inherent parallel mechanism for 3D voxel addressing. High spatial resolution is possible with a full color display being easy to implement. The system is low-cost and low-maintenance.

  6. An Evaluation of Detect and Avoid Displays for UAS: The Effect of Information Level and Display Location on Pilot Performance

    NASA Technical Reports Server (NTRS)

    Rorie, Conrad; Fern, Lisa; Pack, Jessica; Shively, Jay; Draper, Mark H.

    2015-01-01

    The pilot-in-the-loop Detect-and-Avoid (DAA) task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays.

  7. Conceptual Design Standards for eXternal Visibility System (XVS) Sensor and Display Resolution

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Wilz, Susan J.; Arthur, Jarvis J, III

    2012-01-01

    NASA is investigating eXternal Visibility Systems (XVS) concepts which are a combination of sensor and display technologies designed to achieve an equivalent level of safety and performance to that provided by forward-facing windows in today s subsonic aircraft. This report provides the background for conceptual XVS design standards for display and sensor resolution. XVS resolution requirements were derived from the basis of equivalent performance. Three measures were investigated: a) human vision performance; b) see-and-avoid performance and safety; and c) see-to-follow performance. From these three factors, a minimum but perhaps not sufficient resolution requirement of 60 pixels per degree was shown for human vision equivalence. However, see-and-avoid and see-to-follow performance requirements are nearly double. This report also reviewed historical XVS testing.

  8. Capturing and displaying microscopic images used in medical diagnostics and forensic science using 4K video resolution - an application in higher education.

    PubMed

    Maier, Hans; de Heer, Gert; Ortac, Ajda; Kuijten, Jan

    2015-11-01

    To analyze, interpret and evaluate microscopic images, used in medical diagnostics and forensic science, video images for educational purposes were made with a very high resolution of 4096 × 2160 pixels (4K), which is four times as many pixels as High-Definition Video (1920 × 1080 pixels). The unprecedented high resolution makes it possible to see details that remain invisible to any other video format. The images of the specimens (blood cells, tissue sections, hair, fibre, etc.) are recorded using a 4K video camera which is attached to a light microscope. After processing, this resulted in very sharp and highly detailed images. This material was then used in education for classroom discussion. Spoken explanation by experts in the field of medical diagnostics and forensic science was also added to the high-resolution video images to make it suitable for self-study. © 2015 The Authors. Journal of Microscopy published by John Wiley & Sons Ltd on behalf of Royal Microscopical Society.

  9. Automatic optical inspection of regular grid patterns with an inspection camera used below the Shannon-Nyquist criterion for optical resolution

    NASA Astrophysics Data System (ADS)

    Ferreira, Flávio P.; Forte, Paulo M. F.; Felgueiras, Paulo E. R.; Bret, Boris P. J.; Belsley, Michael S.; Nunes-Pereira, Eduardo J.

    2017-02-01

    An Automatic Optical Inspection (AOI) system for optical inspection of imaging devices used in automotive industry using an inspecting optics of lower spatial resolution than the device under inspection is described. This system is robust and with no moving parts. The cycle time is small. Its main advantage is that it is capable of detecting and quantifying defects in regular patterns, working below the Shannon-Nyquist criterion for optical resolution, using a single low resolution image sensor. It is easily scalable, which is an important advantage in industrial applications, since the same inspecting sensor can be reused for increasingly higher spatial resolutions of the devices to be inspected. The optical inspection is implemented with a notch multi-band Fourier filter, making the procedure especially fitted for regular patterns, like the ones that can be produced in image displays and Head Up Displays (HUDs). The regular patterns are used in production line only, for inspection purposes. For image displays, functional defects are detected at the level of a sub-image display grid element unit. Functional defects are the ones impairing the function of the display, and are preferred in AOI to the direct geometric imaging, since those are the ones directly related with the end-user experience. The shift in emphasis from geometric imaging to functional imaging is critical, since it is this that allows quantitative inspection, below Shannon-Nyquist. For HUDs, the functional detect detection addresses defects resulting from the combined effect of the image display and the image forming optics.

  10. Kinetic resolution of sec-alcohols catalysed by Candida antarctica lipase B displaying Pichia pastoris whole-cell biocatalyst.

    PubMed

    Zhang, Kun; Pan, Zhiyou; Diao, Zhoujian; Liang, Shuli; Han, Shuangyan; Zheng, Suiping; Lin, Ying

    2018-03-01

    Kinetic resolution of sec-alcohols is a green process with biocatalyst. Candida antarctica lipase B (CALB) displayed on Pichia pastoris cell-surface (Pp-CALB) was characterized in kinetic resolution of sec-alcohols with different structures. The reaction parameters including acyl donors, molar ratio of substrates, solvents and temperatures were examined with 2-octanol as model substrate. 47.4% molar conversion of 2-octanol and 99.7% ee p were obtained after a 5h reaction with Pp-CALB, and 90% of its original activity still remained after being reused for 10 cycles. Pp-CALB was then used to several sec-alcohols and it showed great enzymatic activity and enantioselectivity to all tested sec-alcohols, more than 93.1% of ee p . The enantioselective characteristics of Pp-CALB catalysed sec-alcohols with different structures were compared with Novozyme 435 which was almost the same. Solvent free system as one way of green chemistry was applied to Pp-CALB and Pp-CALB showed great catalytic activity and enantioselectivity. Pp-CALB was potential biocatalyst of high enzymatic activity and enantioselectivity using in resolution of sec-alcohols. Copyright © 2017. Published by Elsevier Inc.

  11. Micromachined mirrors for raster-scanning displays and optical fiber switches

    NASA Astrophysics Data System (ADS)

    Hagelin, Paul Merritt

    Micromachines and micro-optics have the potential to shrink the size and cost of free-space optical systems, enabling a new generation of high-performance, compact projection displays and telecommunications equipment. In raster-scanning displays and optical fiber switches, a free-space optical beam can interact with multiple tilt- up micromirrors fabricated on a single substrate. The size, rotation angle, and flatness of the mirror surfaces determine the number of pixels in a raster-display or ports in an optical switch. Single-chip and two-chip optical raster display systems demonstrate static mirror curvature correction, an integrated electronic driver board, and dynamic micromirror performance. Correction for curvature caused by a stress gradient in the micromirror leads to resolution of 102 by 119 pixels in the single-chip display. The optical design of the two-chip display features in-situ mirror curvature measurement and adjustable image magnification with a single output lens. An electronic driver board synchronizes modulation of the optical source with micromirror actuation for the display of images. Dynamic off-axis mirror motion is shown to have minimal influence on resolution. The confocal switch, a free-space optical fiber cross- connect, incorporates micromirrors having a design similar to the image-refresh scanner. Two micromirror arrays redirect optical beams from an input fiber array to the output fibers. The switch architecture supports simultaneous switching of multiple wavelength channels. A 2x2 switch configuration, using single-mode optical fiber at 1550 mn, is demonstrated with insertion loss of -4.2 dB and cross-talk of -50.5 dB. The micromirrors have sufficient size and angular range for scaling to a 32x32 cross-connect switch that has low insertion-loss and low cross-talk.

  12. Classification of high resolution remote sensing image based on geo-ontology and conditional random fields

    NASA Astrophysics Data System (ADS)

    Hong, Liang

    2013-10-01

    The availability of high spatial resolution remote sensing data provides new opportunities for urban land-cover classification. More geometric details can be observed in the high resolution remote sensing image, Also Ground objects in the high resolution remote sensing image have displayed rich texture, structure, shape and hierarchical semantic characters. More landscape elements are represented by a small group of pixels. Recently years, the an object-based remote sensing analysis methodology is widely accepted and applied in high resolution remote sensing image processing. The classification method based on Geo-ontology and conditional random fields is presented in this paper. The proposed method is made up of four blocks: (1) the hierarchical ground objects semantic framework is constructed based on geoontology; (2) segmentation by mean-shift algorithm, which image objects are generated. And the mean-shift method is to get boundary preserved and spectrally homogeneous over-segmentation regions ;(3) the relations between the hierarchical ground objects semantic and over-segmentation regions are defined based on conditional random fields framework ;(4) the hierarchical classification results are obtained based on geo-ontology and conditional random fields. Finally, high-resolution remote sensed image data -GeoEye, is used to testify the performance of the presented method. And the experimental results have shown the superiority of this method to the eCognition method both on the effectively and accuracy, which implies it is suitable for the classification of high resolution remote sensing image.

  13. Glucose-neopentyl glycol (GNG) amphiphiles for membrane protein study.

    PubMed

    Chae, Pil Seok; Rana, Rohini R; Gotfryd, Kamil; Rasmussen, Søren G F; Kruse, Andrew C; Cho, Kyung Ho; Capaldi, Stefano; Carlsson, Emil; Kobilka, Brian; Loland, Claus J; Gether, Ulrik; Banerjee, Surajit; Byrne, Bernadette; Lee, John K; Gellman, Samuel H

    2013-03-21

    The development of a new class of surfactants for membrane protein manipulation, "GNG amphiphiles", is reported. These amphiphiles display promising behavior for membrane proteins, as demonstrated recently by the high resolution structure of a sodium-pumping pyrophosphatase reported by Kellosalo et al. (Science, 2012, 337, 473).

  14. Optimum viewing distance for target acquisition

    NASA Astrophysics Data System (ADS)

    Holst, Gerald C.

    2015-05-01

    Human visual system (HVS) "resolution" (a.k.a. visual acuity) varies with illumination level, target characteristics, and target contrast. For signage, computer displays, cell phones, and TVs a viewing distance and display size are selected. Then the number of display pixels is chosen such that each pixel subtends 1 min-1. Resolution of low contrast targets is quite different. It is best described by Barten's contrast sensitivity function. Target acquisition models predict maximum range when the display pixel subtends 3.3 min-1. The optimum viewing distance is nearly independent of magnification. Noise increases the optimum viewing distance.

  15. Ship detection from high-resolution imagery based on land masking and cloud filtering

    NASA Astrophysics Data System (ADS)

    Jin, Tianming; Zhang, Junping

    2015-12-01

    High resolution satellite images play an important role in target detection application presently. This article focuses on the ship target detection from the high resolution panchromatic images. Taking advantage of geographic information such as the coastline vector data provided by NOAA Medium Resolution Coastline program, the land region is masked which is a main noise source in ship detection process. After that, the algorithm tries to deal with the cloud noise which appears frequently in the ocean satellite images, which is another reason for false alarm. Based on the analysis of cloud noise's feature in frequency domain, we introduce a windowed noise filter to get rid of the cloud noise. With the help of morphological processing algorithms adapted to target detection, we are able to acquire ship targets in fine shapes. In addition, we display the extracted information such as length and width of ship targets in a user-friendly way i.e. a KML file interpreted by Google Earth.

  16. Fast I/O for Massively Parallel Applications

    NASA Technical Reports Server (NTRS)

    OKeefe, Matthew T.

    1996-01-01

    The two primary goals for this report were the design, contruction and modeling of parallel disk arrays for scientific visualization and animation, and a study of the IO requirements of highly parallel applications. In addition, further work in parallel display systems required to project and animate the very high-resolution frames resulting from our supercomputing simulations in ocean circulation and compressible gas dynamics.

  17. Naval Research Laboratory 1984 Review.

    DTIC Science & Technology

    1985-07-16

    pulsed infrared comprehensive characterization of ultrahigh trans- sources and electronics for video signal process- parency fluoride glasses and...operates a video system through this port if desired. The optical bench in consisting of visible and infrared television cam- the trailer holds a high...resolution Fourier eras, a high-quality video cassette recorder and transform spectrometer to use in the receiving display, and a digitizer to convert

  18. Presence and preferable viewing conditions when using an ultrahigh-definition large-screen display

    NASA Astrophysics Data System (ADS)

    Masaoka, Kenichiro; Emoto, Masaki; Sugawara, Masayuki; Okano, Fumio

    2005-01-01

    We are investigating psychological aspects to obtain guidelines for the design of TVs aimed at future high-presence broadcasting. In this study, we performed subjective assessment tests to examine the psychological effects of different combinations of viewing conditions obtained by varying the viewing distance, screen size, and picture resolution (between 4000 and 1000 scan lines). The evaluation images were presented in the form of two-minute programs comprising a sequence of 10 still images, and the test subjects were asked to complete a questionnaire consisting of 20 items relating to psychological effects such as "presence", "adverse effects", and "preferability". It was found that the test subjects reported a higher feeling of presence for 1000-line images when viewed around a distance of 1.5H (less than the standard viewing distance of 3H, which is recommended as a viewing distance for subjective evaluation of image quality for HDTV), and reported a higher feeling of presence for 4000-line images than for 1000-line images. The adverse effects such as "difficulty of viewing" did not differ significantly with resolution, but were evaluated to be lower as the viewing distance increased and tended to saturate at viewing distances above 2H. The viewing conditions were evaluated as being more preferable as the screen size increased, showing that it is possible to broadcast comfortable high-presence pictures using high-resolution large-screen displays.

  19. In-flight crew training

    NASA Technical Reports Server (NTRS)

    Gott, Charles; Galicki, Peter; Shores, David

    1990-01-01

    The Helmet Mounted Display system and Part Task Trainer are two projects currently underway that are closely related to the in-flight crew training concept. The first project is a training simulator and an engineering analysis tool. The simulator's unique helmet mounted display actually projects the wearer into the simulated environment of 3-D space. Miniature monitors are mounted in front of the wearers eyes. Partial Task Trainer is a kinematic simulator for the Shuttle Remote Manipulator System. The simulator consists of a high end graphics workstation with a high resolution color screen and a number of input peripherals that create a functional equivalent of the RMS control panel in the back of the Orbiter. It is being used in the training cycle for Shuttle crew members. Activities are underway to expand the capability of the Helmet Display System and the Partial Task Trainer.

  20. Investigation to improve the resolution and range of a light imaging system for very thick tissues

    NASA Astrophysics Data System (ADS)

    Wist, Abund O.; Moon, Peter; Herr, Steven L.; Fatouros, Panos P.

    1995-05-01

    A high resolution light imaging system has been developed utilizing an HeNe (628 nm, 32 mW) and a receiver with post collimation mounted on an x, y table to scan the object. The image can be either recorded on a film or stored in a computer for display on a terminal. Tests show that the system in the regular mode is capable of detecting the spine and soft tissues in anesthetized mice, and of transilluminating fully an adult skull bone with a resolution for details better than one third mm. In teeth, all regular carious lesions, including incipient lesions larger than one third of a mm, can be seen in front or in the back of the tooth, none of which could be detected by dental x-ray systems. Applying a new high resolution mode, the resolution can be increased in teeth to less than 0.1 mm. Some difficulty still exists in detecting small lesions on occlusal or approximal surfaces.

  1. Inkjet printing-based volumetric display projecting multiple full-colour 2D patterns

    NASA Astrophysics Data System (ADS)

    Hirayama, Ryuji; Suzuki, Tomotaka; Shimobaba, Tomoyoshi; Shiraki, Atsushi; Naruse, Makoto; Nakayama, Hirotaka; Kakue, Takashi; Ito, Tomoyoshi

    2017-04-01

    In this study, a method to construct a full-colour volumetric display is presented using a commercially available inkjet printer. Photoreactive luminescence materials are minutely and automatically printed as the volume elements, and volumetric displays are constructed with high resolution using easy-to-fabricate means that exploit inkjet printing technologies. The results experimentally demonstrate the first prototype of an inkjet printing-based volumetric display composed of multiple layers of transparent films that yield a full-colour three-dimensional (3D) image. Moreover, we propose a design algorithm with 3D structures that provide multiple different 2D full-colour patterns when viewed from different directions and experimentally demonstrate prototypes. It is considered that these types of 3D volumetric structures and their fabrication methods based on widely deployed existing printing technologies can be utilised as novel information display devices and systems, including digital signage, media art, entertainment and security.

  2. Blinded evaluation of the effects of high definition and magnification on perceived image quality in laryngeal imaging.

    PubMed

    Otto, Kristen J; Hapner, Edie R; Baker, Michael; Johns, Michael M

    2006-02-01

    Advances in commercial video technology have improved office-based laryngeal imaging. This study investigates the perceived image quality of a true high-definition (HD) video camera and the effect of magnification on laryngeal videostroboscopy. We performed a prospective, dual-armed, single-blinded analysis of a standard laryngeal videostroboscopic examination comparing 3 separate add-on camera systems: a 1-chip charge-coupled device (CCD) camera, a 3-chip CCD camera, and a true 720p (progressive scan) HD camera. Displayed images were controlled for magnification and image size (20-inch [50-cm] display, red-green-blue, and S-video cable for 1-chip and 3-chip cameras; digital visual interface cable and HD monitor for HD camera). Ten blinded observers were then asked to rate the following 5 items on a 0-to-100 visual analog scale: resolution, color, ability to see vocal fold vibration, sense of depth perception, and clarity of blood vessels. Eight unblinded observers were then asked to rate the difference in perceived resolution and clarity of laryngeal examination images when displayed on a 10-inch (25-cm) monitor versus a 42-inch (105-cm) monitor. A visual analog scale was used. These monitors were controlled for actual resolution capacity. For each item evaluated, randomized block design analysis demonstrated that the 3-chip camera scored significantly better than the 1-chip camera (p < .05). For the categories of color and blood vessel discrimination, the 3-chip camera scored significantly better than the HD camera (p < .05). For magnification alone, observers rated the 42-inch monitor statistically better than the 10-inch monitor. The expense of new medical technology must be judged against its added value. This study suggests that HD laryngeal imaging may not add significant value over currently available video systems, in perceived image quality, when a small monitor is used. Although differences in clarity between standard and HD cameras may not be readily apparent on small displays, a large display size coupled with HD technology may impart improved diagnosis of subtle vocal fold lesions and vibratory anomalies.

  3. Grayscale/resolution trade-off for text: Model predictions and psychophysical results for letter confusion and letter discrimination

    NASA Technical Reports Server (NTRS)

    Gille, Jennifer; Martin, Russel; Lubin, Jeffrey; Larimer, James

    1995-01-01

    In a series of papers presented in 1994, we examined the grayscale/resolution trade-off for natural images displayed on devices with discrete pixellation, such as AMLCD's. In the present paper we extend this study by examining the grayscale/resolution trade-off for text images on discrete-pixel displays. Halftoning in printing is an example of the grayscale/resolution trade-off. In printing, spatial resolution is sacrificed to produce grayscale. Another example of this trade-off is the inherent low-pass spatial filter of a CRT, caused by the point-spread function of the electron beam in the phosphor layer. On a CRT, sharp image edges are blurred by this inherent low-pass filtering, and the block noise created by spatial quantization is greatly reduced. A third example of this trade-off is text anti-aliasing, where grayscale is used to improve letter shape, size and location when rendered at a low spatial resolution. There are additional implications for display system design from the grayscale/resolution trade-off. For example, reduced grayscale can reduce system costs by requiring less complexity in the framestore, allowing the use of lower cost drivers, potentially increasing data transfer rates in the image subsystem, and simplifying the manufacturing processes that are used to construct the active matrix for AMLCD (active-matrix liquid-crystal display) or AMTFEL (active-matrix thin-film electroluminescent) devices. Therefore, the study of these trade-offs is important for display designers and manufacturing and systems engineers who wish to create the highest performance, lowest cost device possible. Our strategy for investigating this trade-off is to generate a set of simple test images, manipulate grayscale and resolution, predict discrimination performance using the ViDEOS(Sarnoff) Human Vision Model, conduct an empirical study of discrimination using psychophysical procedures, and verify the computational results using the psychophysical results.

  4. SeeGH--a software tool for visualization of whole genome array comparative genomic hybridization data.

    PubMed

    Chi, Bryan; DeLeeuw, Ronald J; Coe, Bradley P; MacAulay, Calum; Lam, Wan L

    2004-02-09

    Array comparative genomic hybridization (CGH) is a technique which detects copy number differences in DNA segments. Complete sequencing of the human genome and the development of an array representing a tiling set of tens of thousands of DNA segments spanning the entire human genome has made high resolution copy number analysis throughout the genome possible. Since array CGH provides signal ratio for each DNA segment, visualization would require the reassembly of individual data points into chromosome profiles. We have developed a visualization tool for displaying whole genome array CGH data in the context of chromosomal location. SeeGH is an application that translates spot signal ratio data from array CGH experiments to displays of high resolution chromosome profiles. Data is imported from a simple tab delimited text file obtained from standard microarray image analysis software. SeeGH processes the signal ratio data and graphically displays it in a conventional CGH karyotype diagram with the added features of magnification and DNA segment annotation. In this process, SeeGH imports the data into a database, calculates the average ratio and standard deviation for each replicate spot, and links them to chromosome regions for graphical display. Once the data is displayed, users have the option of hiding or flagging DNA segments based on user defined criteria, and retrieve annotation information such as clone name, NCBI sequence accession number, ratio, base pair position on the chromosome, and standard deviation. SeeGH represents a novel software tool used to view and analyze array CGH data. The software gives users the ability to view the data in an overall genomic view as well as magnify specific chromosomal regions facilitating the precise localization of genetic alterations. SeeGH is easily installed and runs on Microsoft Windows 2000 or later environments.

  5. Fast repurposing of high-resolution stereo video content for mobile use

    NASA Astrophysics Data System (ADS)

    Karaoglu, Ali; Lee, Bong Ho; Boev, Atanas; Cheong, Won-Sik; Gotchev, Atanas

    2012-06-01

    3D video content is captured and created mainly in high resolution targeting big cinema or home TV screens. For 3D mobile devices, equipped with small-size auto-stereoscopic displays, such content has to be properly repurposed, preferably in real-time. The repurposing requires not only spatial resizing but also properly maintaining the output stereo disparity, as it should deliver realistic, pleasant and harmless 3D perception. In this paper, we propose an approach to adapt the disparity range of the source video to the comfort disparity zone of the target display. To achieve this, we adapt the scale and the aspect ratio of the source video. We aim at maximizing the disparity range of the retargeted content within the comfort zone, and minimizing the letterboxing of the cropped content. The proposed algorithm consists of five stages. First, we analyse the display profile, which characterises what 3D content can be comfortably observed in the target display. Then, we perform fast disparity analysis of the input stereoscopic content. Instead of returning the dense disparity map, it returns an estimate of the disparity statistics (min, max, meanand variance) per frame. Additionally, we detect scene cuts, where sharp transitions in disparities occur. Based on the estimated input, and desired output disparity ranges, we derive the optimal cropping parameters and scale of the cropping window, which would yield the targeted disparity range and minimize the area of cropped and letterboxed content. Once the rescaling and cropping parameters are known, we perform resampling procedure using spline-based and perceptually optimized resampling (anti-aliasing) kernels, which have also a very efficient computational structure. Perceptual optimization is achieved through adjusting the cut-off frequency of the anti-aliasing filter with the throughput of the target display.

  6. Development of a tactile display with 5 mm resolution using an array of magnetorheological fluid

    NASA Astrophysics Data System (ADS)

    Ishizuka, Hiroki; Miki, Norihisa

    2017-06-01

    In this study, we demonstrate the design and evaluation of a stiffness tactile display using a magnetorheological (MR) fluid. The tactile display is based on the change in mechanical properties under an external magnetic field. In the tactile display, the MR fluid is encapsulated in chambers of 3 mm diameter and arranged at intervals of 2 mm. Magnetic fields were spatially applied to the tactile display using neodymium magnets of 3.5 mm diameter. The design and spatial magnetic field application enable the tactile display to present stiff dots of 5 mm resolution. We confirmed that the tactile display can present a spatial stiff dot and its pattern on the surface by compression experiments. Sensory evaluation revealed that the users were able to perceive the approximate position of the stiff dots. From the experiments, the tactile display has potential as a palpation tactile display and requires improvement to present various types of tissues.

  7. Gray scale enhances display readability of bitmapped documents

    NASA Astrophysics Data System (ADS)

    Ostberg, Olov; Disfors, Dennis; Feng, Yingduo

    1994-05-01

    Bitmapped images of high resolution, say 300 dpi rastered documents, stored in the memory of a PC are at best only borderline readable on the PC's display screen (say a 72 dpi VGA monitor). Results from a series of exploratory psycho-physical experiments, using the Adobe PhotoshopR software, show that the readability can be significantly enhanced by making use of the monitor's capability to display shades of gray. It is suggested that such a gray scale adaptation module should be bundled to all software products for electronic document management. In fact, fax modems are already available in which this principle is employed, hereby making it possible to read incoming fax documents directly on the screen.

  8. Plant Tissues in 3D via X-Ray Tomography: Simple Contrasting Methods Allow High Resolution Imaging

    PubMed Central

    Staedler, Yannick M.; Masson, David; Schönenberger, Jürg

    2013-01-01

    Computed tomography remains strongly underused in plant sciences despite its high potential in delivering detailed 3D phenotypical information because of the low X-ray absorption of most plant tissues. Existing protocols to study soft tissues display poor performance, especially when compared to those used on animals. More efficient protocols to study plant material are therefore needed. Flowers of Arabidopsis thaliana and Marcgravia caudata were immersed in a selection of contrasting agents used to treat samples for transmission electron microscopy. Grayscale values for floral tissues and background were measured as a function of time. Contrast was quantified via a contrast index. The thick buds of Marcgravia were scanned to determine which contrasting agents best penetrate thick tissues. The highest contrast increase with cytoplasm-rich tissues was obtained with phosphotungstate, whereas osmium tetroxide and bismuth tatrate displayed the highest contrast increase with vacuolated tissues. Phosphotungstate also displayed the best sample penetration. Furthermore, infiltration with phosphotungstate allowed imaging of all plants parts at a high resolution of 3 µm, which approaches the maximum resolution of our equipment: 1.5 µm. The high affinity of phosphotungstate for vasculature, cytoplasm-rich tissue, and pollen causes these tissues to absorb more X-rays than the surrounding tissues, which, in turn, makes these tissues appear brighter on the scan data. Tissues with different brightness can then be virtually dissected from each other by selecting the bracket of grayscale to be visualized. Promising directions for the future include in silico phenotyping and developmental studies of plant inner parts (e.g., ovules, vasculature, pollen, and cell nuclei) via virtual dissection as well as correlations of quantitative phenotypes with omics datasets. Therefore, this work represents a crucial improvement of previous methods, allowing new directions of research to be undertaken in areas ranging from morphology to systems biology. PMID:24086499

  9. High-definition television evaluation for remote handling task performance

    NASA Astrophysics Data System (ADS)

    Fujita, Y.; Omori, E.; Hayashi, S.; Draper, J. V.; Herndon, J. N.

    Described are experiments designed to evaluate the impact of HDTV (High-Definition Television) on the performance of typical remote tasks. The experiments described in this paper compared the performance of four operators using HDTV with their performance while using other television systems. The experiments included four television systems: (1) high-definition color television, (2) high-definition monochromatic television, (3) standard-resolution monochromatic television, and (4) standard-resolution stereoscopic monochromatic television. The stereo system accomplished stereoscopy by displaying two cross-polarized images, one reflected by a half-silvered mirror and one seen through the mirror. Observers wore spectacles with cross-polarized lenses so that the left eye received only the view from the left camera and the right eye received only the view from the right camera.

  10. Glucose-Neopentyl Glycol (GNG) Amphiphiles for Membrane Protein Solubilization, Stabilization and Crystallization

    PubMed Central

    Rana, Rohini R.; Gotfryd, Kamil; Rasmussen, Søren G. F.; Kruse, Andrew C.; Cho, Kyung Ho; Capaldi, Stefano; Carlsson, Emil; Kobilka, Brian; Loland, Claus J.; Gether, Ulrik; Banerjee, Surajit

    2012-01-01

    The development of a new class of surfactants for membrane protein manipulation, “GNG amphiphiles”, is reported. These amphiphiles display promising behavior for membrane proteins, as demonstrated recently by the high resolution structure of a sodium-pumping pyrophosphatase reported by Kellosalo et al. PMID:23165475

  11. Evaluation of the sparse coding super-resolution method for improving image quality of up-sampled images in computed tomography

    NASA Astrophysics Data System (ADS)

    Ota, Junko; Umehara, Kensuke; Ishimaru, Naoki; Ohno, Shunsuke; Okamoto, Kentaro; Suzuki, Takanori; Shirai, Naoki; Ishida, Takayuki

    2017-02-01

    As the capability of high-resolution displays grows, high-resolution images are often required in Computed Tomography (CT). However, acquiring high-resolution images takes a higher radiation dose and a longer scanning time. In this study, we applied the Sparse-coding-based Super-Resolution (ScSR) method to generate high-resolution images without increasing the radiation dose. We prepared the over-complete dictionary learned the mapping between low- and highresolution patches and seek a sparse representation of each patch of the low-resolution input. These coefficients were used to generate the high-resolution output. For evaluation, 44 CT cases were used as the test dataset. We up-sampled images up to 2 or 4 times and compared the image quality of the ScSR scheme and bilinear and bicubic interpolations, which are the traditional interpolation schemes. We also compared the image quality of three learning datasets. A total of 45 CT images, 91 non-medical images, and 93 chest radiographs were used for dictionary preparation respectively. The image quality was evaluated by measuring peak signal-to-noise ratio (PSNR) and structure similarity (SSIM). The differences of PSNRs and SSIMs between the ScSR method and interpolation methods were statistically significant. Visual assessment confirmed that the ScSR method generated a high-resolution image with sharpness, whereas conventional interpolation methods generated over-smoothed images. To compare three different training datasets, there were no significance between the CT, the CXR and non-medical datasets. These results suggest that the ScSR provides a robust approach for application of up-sampling CT images and yields substantial high image quality of extended images in CT.

  12. Improved Interactive Medical-Imaging System

    NASA Technical Reports Server (NTRS)

    Ross, Muriel D.; Twombly, Ian A.; Senger, Steven

    2003-01-01

    An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

  13. A laser induced local transfer for patterning of RGB-OLED-displays

    NASA Astrophysics Data System (ADS)

    Kroeger, Michael; Hueske, Marc; Dobbertin, Thomas; Meyer, Jens; Krautwald, Henning; Riedl, Thomas; Johannes, Hans-Hermann; Kowalsky, Wolfgang

    2005-07-01

    RGB-OLED-displays can be realized by at least three different approaches: Color from white, color from blue or patterning of red, green and blue OLEDs, which is favorable for reasons of higher efficiency and lower costs. Common patterning techniques like photolithography cannot be applied due to the degradation of the OLEDs after the exposure to solvents. Shadow masking which is currently widely applied is not applicable for bigger substrate sizes of future mass production tools. Therefore a novel approach for patterning of organic semiconductors will be demonstrated. The laser induced local transfer (LILT) of organic small molecule materials allows for mass production of high resolution RGB-OLED-displays. An infrared absorbing target is coated with the desired emitting material, which is placed in a short distance in front of an OLED substrate. A scanner deflects and focuses an infrared laser beam onto the target. By adjusting scanning speed and laser power accurately the target locally heats up to a temperature where the organic material sublimes and will be deposited on the opposite OLED substrate. By repeating this for red, green and blue emitting materials a RGB-OLED-display can be realized. For process evaluation and development a LILT-module has been built, incorporating two custom vacuum chambers, several lift and transfer stages, a high-speed high-precision scanner and an infrared continuous-wave laser (cw). This module is designed to be part of a future inline deposition system for full-color OLED displays. In the first experiments it could be observed, that the pattern resolution is strongly dependent on the scanning speed, exhibiting minimum feature sizes of 40μm. It can be deducted that this is due to the laser's beam profile (TEM00), which allows for the smallest focus possible, but may not allow for rugged process conditions suitable for production. Rectangular steep-edged beam profiles may overcome this problem.

  14. Large-screen display technology assessment for military applications

    NASA Astrophysics Data System (ADS)

    Blaha, Richard J.

    1990-08-01

    Full-color, large screen display systems can enhance military applications that require group presentation, coordinated decisions, or interaction between decision makers. The technology already plays an important role in operations centers, simulation facilities, conference rooms, and training centers. Some applications display situational, status, or briefing information, while others portray instructional material for procedural training or depict realistic panoramic scenes that are used in simulators. While each specific application requires unique values of luminance, resolution, response time, reliability, and the video interface, suitable performance can be achieved with available commercial large screen displays. Advances in the technology of large screen displays are driven by the commercial applications because the military applications do not provide the significant market share enjoyed by high definition television (HDTV), entertainment, advertisement, training, and industrial applications. This paper reviews the status of full-color, large screen display technologies and includes the performance and cost metrics of available systems. For this discussion, performance data is based upon either measurements made by our personnel or extractions from vendors' data sheets.

  15. Recent progress in OLED and flexible displays and their potential for application to aerospace and military display systems

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri

    2015-05-01

    Organic light emitting diode (OLED) display technology has advanced significantly in recent years and it is increasingly being adapted in consumer electronics products with premium performance, such as high resolution smart phones, Tablet PCs and TVs. Even flexible OLED displays are beginning to be commercialized in consumer electronic devices such as smart phones and smart watches. In addition to the advances in OLED emitters, successful development and adoption of OLED displays for premium performance applications relies on the advances in several enabling technologies including TFT backplanes, pixel drive electronics, pixel patterning technologies, encapsulation technologies and system level engineering. In this paper we will discuss the impact of the recent advances in LTPS and AOS TFTs, R, G, B and White OLED with color filter pixel architectures, and encapsulation, on the success of the OLEDs in consumer electronic devices. We will then discuss potential of these advances in addressing the requirements of OLED and flexible displays for the military and avionics applications.

  16. High-resolution dynamic pressure sensor array based on piezo-phototronic effect tuned photoluminescence imaging.

    PubMed

    Peng, Mingzeng; Li, Zhou; Liu, Caihong; Zheng, Qiang; Shi, Xieqing; Song, Ming; Zhang, Yang; Du, Shiyu; Zhai, Junyi; Wang, Zhong Lin

    2015-03-24

    A high-resolution dynamic tactile/pressure display is indispensable to the comprehensive perception of force/mechanical stimulations such as electronic skin, biomechanical imaging/analysis, or personalized signatures. Here, we present a dynamic pressure sensor array based on pressure/strain tuned photoluminescence imaging without the need for electricity. Each sensor is a nanopillar that consists of InGaN/GaN multiple quantum wells. Its photoluminescence intensity can be modulated dramatically and linearly by small strain (0-0.15%) owing to the piezo-phototronic effect. The sensor array has a high pixel density of 6350 dpi and exceptional small standard deviation of photoluminescence. High-quality tactile/pressure sensing distribution can be real-time recorded by parallel photoluminescence imaging without any cross-talk. The sensor array can be inexpensively fabricated over large areas by semiconductor product lines. The proposed dynamic all-optical pressure imaging with excellent resolution, high sensitivity, good uniformity, and ultrafast response time offers a suitable way for smart sensing, micro/nano-opto-electromechanical systems.

  17. Ultrahigh-resolution endoscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Herz, Paul R.; Hsiung, Pei-Lin; Aguirre, Aaron D.; Mashimo, Hiroshi; Desai, Saleem; Pedrosa, Macos; Koski, Amanda; Schmitt, Joseph M.; Fujimoto, James G.

    2005-01-01

    Early detection of gastrointestinal cancer is essential for the patient treatment and medical care. Endoscopically guided biopsy is currently the gold standard for the diagnosis of early esophageal cancer, but can suffer from high false negative rates due to sampling errors. Optical coherence tomography (OCT) is an emerging medical imaging technology which can generate high resolution, cross-sectional images of tissue in situ and in real time, without the removal of tissue specimen. Although endoscopic OCT has been used successfully to identify certain pathologies in the gastrointestinal tract, the resolution of current endoscopic OCT systems has been limited to 10 - 15 m for clinical procedures. In this study, in vivo imaging of the gastrointestinal tract is demonstrated at a three-fold higher resolution (< 5 m), using a portable, broadband, Cr4+:Forsterite laser as the optical light source. Images acquired from the esophagus, gastro-esophageal junction and colon on animal model display tissue microstructures and architectural details at high resolution, and the features observed in the OCT images are well-matched with histology. The clinical feasibility study is conducted through delivering OCT imaging catheter using standard endoscope. OCT images of normal esophagus, Barrett's esophagus, and esophageal cancers are demonstrated with distinct features. The ability of high resolution endoscopic OCT to image tissue morphology at an unprecedented resolution in vivo would facilitate the development of OCT as a potential imaging modality for early detection of neoplastic changes.

  18. Multimaterial 4D Printing with Tailorable Shape Memory Polymers

    PubMed Central

    Ge, Qi; Sakhaei, Amir Hosein; Lee, Howon; Dunn, Conner K.; Fang, Nicholas X.; Dunn, Martin L.

    2016-01-01

    We present a new 4D printing approach that can create high resolution (up to a few microns), multimaterial shape memory polymer (SMP) architectures. The approach is based on high resolution projection microstereolithography (PμSL) and uses a family of photo-curable methacrylate based copolymer networks. We designed the constituents and compositions to exhibit desired thermomechanical behavior (including rubbery modulus, glass transition temperature and failure strain which is more than 300% and larger than any existing printable materials) to enable controlled shape memory behavior. We used a high resolution, high contrast digital micro display to ensure high resolution of photo-curing methacrylate based SMPs that requires higher exposure energy than more common acrylate based polymers. An automated material exchange process enables the manufacture of 3D composite architectures from multiple photo-curable SMPs. In order to understand the behavior of the 3D composite microarchitectures, we carry out high fidelity computational simulations of their complex nonlinear, time-dependent behavior and study important design considerations including local deformation, shape fixity and free recovery rate. Simulations are in good agreement with experiments for a series of single and multimaterial components and can be used to facilitate the design of SMP 3D structures. PMID:27499417

  19. Arrival Metering Precision Study

    NASA Technical Reports Server (NTRS)

    Prevot, Thomas; Mercer, Joey; Homola, Jeffrey; Hunt, Sarah; Gomez, Ashley; Bienert, Nancy; Omar, Faisal; Kraut, Joshua; Brasil, Connie; Wu, Minghong, G.

    2015-01-01

    This paper describes the background, method and results of the Arrival Metering Precision Study (AMPS) conducted in the Airspace Operations Laboratory at NASA Ames Research Center in May 2014. The simulation study measured delivery accuracy, flight efficiency, controller workload, and acceptability of time-based metering operations to a meter fix at the terminal area boundary for different resolution levels of metering delay times displayed to the air traffic controllers and different levels of airspeed information made available to the Time-Based Flow Management (TBFM) system computing the delay. The results show that the resolution of the delay countdown timer (DCT) on the controllers display has a significant impact on the delivery accuracy at the meter fix. Using the 10 seconds rounded and 1 minute rounded DCT resolutions resulted in more accurate delivery than 1 minute truncated and were preferred by the controllers. Using the speeds the controllers entered into the fourth line of the data tag to update the delay computation in TBFM in high and low altitude sectors increased air traffic control efficiency and reduced fuel burn for arriving aircraft during time based metering.

  20. Zone plate method for electronic holographic display using resolution redistribution technique.

    PubMed

    Takaki, Yasuhiro; Nakamura, Junya

    2011-07-18

    The resolution redistribution (RR) technique can increase the horizontal viewing-zone angle and screen size of electronic holographic display. The present study developed a zone plate method that would reduce hologram calculation time for the RR technique. This method enables calculation of an image displayed on a spatial light modulator by performing additions of the zone plates, while the previous calculation method required performing the Fourier transform twice. The derivation and modeling of the zone plate are shown. In addition, the look-up table approach was introduced for further reduction in computation time. Experimental verification using a holographic display module based on the RR technique is presented.

  1. Display technologies for augmented reality

    NASA Astrophysics Data System (ADS)

    Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang

    2018-02-01

    With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.

  2. The high velocity symbiotic star AG Draconis after its 1980 outburst

    NASA Technical Reports Server (NTRS)

    Viotti, R.; Altamore, A.; Baratta, G. B.; Cassatella, A.; Friedjung, M.; Giangrande, A.; Ponz, D.; Ricciardi, O.

    1982-01-01

    High and low resolution spectra of AG Dra taken in 1981 are analyzed. The UV spectrum of AG Dra is characterized by prominent high ionization emission lines superimposed on a strong continuum. At high resolution, several intense absorption lines of interstellar origin are seen, in spite of the low interstellar extinction. A similar situation is displayed by the high galactic latitude sd0 stars. The radial velocity difference between the emission lines and the i.s. lines is about -105 Km/sec in agreement with the optical observations. The He II 1640 A line appears much stronger than in other symbiotic stars and suggests the presence of a hot source which is variable according to the activity of the star. The line also exhibits broad emission wings which could be formed in a rotating disk. The NV resonance doublet displays a P Cygni profile and is probably formed in a warm wind. Two components in the UV continuum are identified: a steep component dominating the far UV probably associated with the hot source, and a flatter continuum in the near UV which cannot be accounted for by f-f and f-b emission alone, but which is probably emitted by an optically thick region or disk.

  3. Resolution analysis of archive films for the purpose of their optimal digitization and distribution

    NASA Astrophysics Data System (ADS)

    Fliegel, Karel; Vítek, Stanislav; Páta, Petr; Myslík, Jiří; Pecák, Josef; Jícha, Marek

    2017-09-01

    With recent high demand for ultra-high-definition (UHD) content to be screened in high-end digital movie theaters but also in the home environment, film archives full of movies in high-definition and above are in the scope of UHD content providers. Movies captured with the traditional film technology represent a virtually unlimited source of UHD content. The goal to maintain complete image information is also related to the choice of scanning resolution and spatial resolution for further distribution. It might seem that scanning the film material in the highest possible resolution using state-of-the-art film scanners and also its distribution in this resolution is the right choice. The information content of the digitized images is however limited, and various degradations moreover lead to its further reduction. Digital distribution of the content in the highest image resolution might be therefore unnecessary or uneconomical. In other cases, the highest possible resolution is inevitable if we want to preserve fine scene details or film grain structure for archiving purposes. This paper deals with the image detail content analysis of archive film records. The resolution limit in captured scene image and factors which lower the final resolution are discussed. Methods are proposed to determine the spatial details of the film picture based on the analysis of its digitized image data. These procedures allow determining recommendations for optimal distribution of digitized video content intended for various display devices with lower resolutions. Obtained results are illustrated on spatial downsampling use case scenario, and performance evaluation of the proposed techniques is presented.

  4. Evaluation of display technologies for Internet of Things (IoT)

    NASA Astrophysics Data System (ADS)

    Sabo, Julia; Fegert, Tobias; Cisowski, Matthäus Stephanus; Marsal, Anatolij; Eichberger, Domenik; Blankenbach, Karlheinz

    2017-02-01

    Internet of Things (IoT) is a booming industry. We investigated several (semi-) professional IoT devices in combination with displays (focus on reflective technologies) and LEDs. First, these displays were compared for reflectance and ambient light performance. Two measurement set-ups with diffuse conditions were used for simulating typical indoor lighting conditions of IoT displays. E-paper displays were evaluated best as they combine a relative high reflectance with large contrast ratio. Reflective monochrome LCDs show a lower reflectance but are widely available. Second we studied IoT microprocessors interfaces to displays. A µP can drive single LEDs and one or two Seg 8 LED digits directly by GPIOs. Other display technologies require display controllers with a parallel or serial interface to the microprocessor as they need dedicated waveforms for driving the pixels. Most suitable are display modules with built-in display RAM as only pixel data have to be transferred which changes. A HDMI output (e.g. Raspberry Pi) results in high cost for the displays, therefore AMLCDs are not suitable for low to medium cost IoT systems. We compared and evaluated furthermore status indicators, icons, text and graphics IoT display systems regarding human machine interface (HMI) characteristics and effectiveness as well as power consumption. We found out that low resolution graphics bistable e-paper displays are the most appropriate display technology for IoT systems as they show as well information after a power failure or power switch off during maintenance or e.g. QR codes for installation. LED indicators are the most cost effective approach which has however very limited HMI capabilities.

  5. The Effect of Ownship Information and NexRad Resolution on Pilot Decision Making in the Use of a Cockpit Weather Information Display

    NASA Technical Reports Server (NTRS)

    Novacek, Paul F.; Burgess, Malcolm A.; Heck, Michael L.; Stokes, Alan F.; Stough, H. Paul, III (Technical Monitor)

    2001-01-01

    A two-phase experiment was conducted to explore the effects of data-link weather displays upon pilot decision performance. The experiment was conducted with 49 instrument rated pilots who were divided into four groups and placed in a simulator with a realistic flight scenario involving weather containing convective activity. The inflight weather display depicted NEXRAD images, with graphical and textual METARs over a moving map display. The experiment explored the effect of weather information, ownship position symbology and NEXRAD cell size resolution. The phase-two experiment compared two groups using the data-linked weather display with ownship position symbology. These groups were compared to the phase-one group that did not have ownship position symbology. The phase-two pilots were presented with either large NEXRAD cell size (8 km) or small cell size (4 km). Observations noted that the introduction of ownship symbology did not appear to significantly impact the decision making process, however, the introduction of ownship did reduce workload. Additionally, NEXRAD cell size resolution did appear to influence the tactical decision making process.

  6. Capability of AVHRR data in discriminating rangeland cover mixtures

    USGS Publications Warehouse

    Senay, Gabriel B.; Elliott, R.L.

    2002-01-01

    A combination of high temporal resolution Advanced Very High Resolution Radiometer (AVHRR) data and high spatial information Map Information Analysis and Display System (MIADS) landuse/landcover data from the United States Department of Agriculture-Natural Resources Conservation Service (USDA-NRCS) were used to investigate the feasibility of using the combined dataset for regional evapotranspiration (ET) studies. It was shown that the biweekly maximum Normalized Difference Vegetation Index (NDVI) composite AVHRR data were capable of discriminating rangelands with different types of trees and shrubs species. AVHRR data also showed a potential to distinguish canopy cover differences within a mix of similar species. The combination of MIADS data and AVHRR data can be used to study temporal dynamics of various cover types for use in regional ET estimates.

  7. Application of the high resolution return beam vidicon

    NASA Technical Reports Server (NTRS)

    Cantella, M. J.

    1977-01-01

    The Return Beam Vidicon (RBV) is a high-performance electronic image sensor and electrical storage component. It can accept continuous or discrete exposures. Information can be read out with a single scan or with many repetitive scans for either signal processing or display. Resolution capability is 10,000 TV lines/height, and at 100 lp/mm, performance matches or exceeds that of film, particularly with low-contrast imagery. Electronic zoom can be employed effectively for image magnification and data compression. The high performance and flexibility of the RBV permit wide application in systems for reconnaissance, scan conversion, information storage and retrieval, and automatic inspection and test. This paper summarizes the characteristics and performance parameters of the RBV and cites examples of feasible applications.

  8. A New Era in Medical Training Through Simulation-Based Training Systems

    DTIC Science & Technology

    2010-04-01

    next steps is to seek initial verification against published data. 2.2 Ultra-High Resolution Display for Army Medicine (UHRDARM) The eMagin ...view between 60 and 80 degrees while only consuming less than 2 watts of total power consumption. Figures 1 and 2: Photos courtesy of eMagin

  9. High-resolution CT assessment of the pediatric airways: structure and function

    NASA Astrophysics Data System (ADS)

    Kramer, Sandra S.; Hoffman, Eric A.; Amirav, Israel

    1994-05-01

    The airway has always been a central focus for respiratory pathology in infants and children. Imaging of the larynx, trachea, and the central bronchi can be readily accomplished by radiographic or conventional CT techniques. Newer high resolution CT (HRCT) techniques have extended our view of the bronchi peripherally to the limits of scanner resolution, i.e., to bronchial generations 7 - 9, and rapid volumetric CT data acquisitions have made it possible to follow the same lung anatomic level through the rapidly occurring changes in a series of experimental protocols. These techniques together with a custom designed computer software program for image display and analysis have enabled us to objectively study changes in airway caliber and lung density that occurred in an animal mode of airway reactivity and thereby relate structure with function in the airways.

  10. Ultrasonic Ranging System With Increased Resolution

    NASA Technical Reports Server (NTRS)

    Meyer, William E.; Johnson, William G.

    1987-01-01

    Master-oscillator frequency increased. Ultrasonic range-measuring system with 0.1-in. resolution provides continuous digital display of four distance readings, each updated four times per second. Four rangefinder modules in system are modified versions of rangefinder used for automatic focusing in commercial series of cameras. Ultrasonic pulses emitted by system innocuous to both people and equipment. Provides economical solutions to such distance-measurement problems as posed by boats approaching docks, truck backing toward loading platform, runway-clearance readout for tail of airplane with high angle attack, or burglar alarm.

  11. Defense applications of the CAVE (CAVE automatic virtual environment)

    NASA Astrophysics Data System (ADS)

    Isabelle, Scott K.; Gilkey, Robert H.; Kenyon, Robert V.; Valentino, George; Flach, John M.; Spenny, Curtis H.; Anderson, Timothy R.

    1997-07-01

    The CAVE is a multi-person, room-sized, high-resolution, 3D video and auditory environment, which can be used to present very immersive virtual environment experiences. This paper describes the CAVE technology and the capability of the CAVE system as originally developed at the Electronics Visualization Laboratory of the University of Illinois- Chicago and as more recently implemented by Wright State University (WSU) in the Armstrong Laboratory at Wright- Patterson Air Force Base (WPAFB). One planned use of the WSU/WPAFB CAVE is research addressing the appropriate design of display and control interfaces for controlling uninhabited aerial vehicles. The WSU/WPAFB CAVE has a number of features that make it well-suited to this work: (1) 360 degrees surround, plus floor, high resolution visual displays, (2) virtual spatialized audio, (3) the ability to integrate real and virtual objects, and (4) rapid and flexible reconfiguration. However, even though the CAVE is likely to have broad utility for military applications, it does have certain limitations that may make it less well- suited to applications that require 'natural' haptic feedback, vestibular stimulation, or an ability to interact with close detailed objects.

  12. Visual analytics of inherently noisy crowdsourced data on ultra high resolution displays

    NASA Astrophysics Data System (ADS)

    Huynh, Andrew; Ponto, Kevin; Lin, Albert Yu-Min; Kuester, Falko

    The increasing prevalence of distributed human microtasking, crowdsourcing, has followed the exponential increase in data collection capabilities. The large scale and distributed nature of these microtasks produce overwhelming amounts of information that is inherently noisy due to the nature of human input. Furthermore, these inputs create a constantly changing dataset with additional information added on a daily basis. Methods to quickly visualize, filter, and understand this information over temporal and geospatial constraints is key to the success of crowdsourcing. This paper present novel methods to visually analyze geospatial data collected through crowdsourcing on top of remote sensing satellite imagery. An ultra high resolution tiled display system is used to explore the relationship between human and satellite remote sensing data at scale. A case study is provided that evaluates the presented technique in the context of an archaeological field expedition. A team in the field communicated in real-time with and was guided by researchers in the remote visual analytics laboratory, swiftly sifting through incoming crowdsourced data to identify target locations that were identified as viable archaeological sites.

  13. Synthetic aperture radar operator tactical target acquisition research

    NASA Technical Reports Server (NTRS)

    Hershberger, M. L.; Craig, D. W.

    1978-01-01

    A radar target acquisition research study was conducted to access the effects of two levels of 13 radar sensor, display, and mission parameters on operator tactical target acquisition. A saturated fractional-factorial screening design was employed to examine these parameters. Data analysis computed ETA squared values for main and second-order effects for the variables tested. Ranking of the research parameters in terms of importance to system design revealed four variables (radar coverage, radar resolution/multiple looks, display resolution, and display size) accounted for 50 percent of the target acquisition probability variance.

  14. Display system employing acousto-optic tunable filter

    NASA Technical Reports Server (NTRS)

    Lambert, James L. (Inventor)

    1995-01-01

    An acousto-optic tunable filter (AOTF) is employed to generate a display by driving the AOTF with a RF electrical signal comprising modulated red, green, and blue video scan line signals and scanning the AOTF with a linearly polarized, pulsed light beam, resulting in encoding of color video columns (scan lines) of an input video image into vertical columns of the AOTF output beam. The AOTF is illuminated periodically as each acoustically-encoded scan line fills the cell aperture of the AOTF. A polarizing beam splitter removes the unused first order beam component of the AOTF output and, if desired, overlays a real world scene on the output plane. Resolutions as high as 30,000 lines are possible, providing holographic display capability.

  15. Display system employing acousto-optic tunable filter

    NASA Technical Reports Server (NTRS)

    Lambert, James L. (Inventor)

    1993-01-01

    An acousto-optic tunable filter (AOTF) is employed to generate a display by driving the AOTF with a RF electrical signal comprising modulated red, green, and blue video scan line signals and scanning the AOTF with a linearly polarized, pulsed light beam, resulting in encoding of color video columns (scan lines) of an input video image into vertical columns of the AOTF output beam. The AOTF is illuminated periodically as each acoustically-encoded scan line fills the cell aperture of the AOTF. A polarizing beam splitter removes the unused first order beam component of the AOTF output and, if desired, overlays a real world scene on the output plane. Resolutions as high as 30,000 lines are possible, providing holographic display capability.

  16. Zonal wavefront sensing with enhanced spatial resolution.

    PubMed

    Pathak, Biswajit; Boruah, Bosanta R

    2016-12-01

    In this Letter, we introduce a scheme to enhance the spatial resolution of a zonal wavefront sensor. The zonal wavefront sensor comprises an array of binary gratings implemented by a ferroelectric spatial light modulator (FLCSLM) followed by a lens, in lieu of the array of lenses in the Shack-Hartmann wavefront sensor. We show that the fast response of the FLCSLM device facilitates quick display of several laterally shifted binary grating patterns, and the programmability of the device enables simultaneous capturing of each focal spot array. This eventually leads to a wavefront estimation with an enhanced spatial resolution without much sacrifice on the sensor frame rate, thus making the scheme suitable for high spatial resolution measurement of transient wavefronts. We present experimental and numerical simulation results to demonstrate the importance of the proposed wavefront sensing scheme.

  17. New Algorithm to Enable Construction and Display of 3D Structures from Scanning Probe Microscopy Images Acquired Layer-by-Layer.

    PubMed

    Deng, William Nanqiao; Wang, Shuo; Ventrici de Souza, Joao; Kuhl, Tonya L; Liu, Gang-Yu

    2018-06-25

    Scanning probe microscopy (SPM), such as atomic force microscopy (AFM), is widely known for high-resolution imaging of surface structures and nanolithography in two dimensions (2D), providing important physical insights into surface science and material science. This work reports a new algorithm to enable construction and display of layer-by-layer 3D structures from SPM images. The algorithm enables alignment of SPM images acquired during layer-by-layer deposition and removal of redundant features and faithfully constructs the deposited 3D structures. The display uses a "see-through" strategy to enable the structure of each layer to be visible. The results demonstrate high spatial accuracy as well as algorithm versatility; users can set parameters for reconstruction and display as per image quality and research needs. To the best of our knowledge, this method represents the first report to enable SPM technology for 3D imaging construction and display. The detailed algorithm is provided to facilitate usage of the same approach in any SPM software. These new capabilities support wide applications of SPM that require 3D image reconstruction and display, such as 3D nanoprinting and 3D additive and subtractive manufacturing and imaging.

  18. Passive method of eliminating accommodation/convergence disparity in stereoscopic head-mounted displays

    NASA Astrophysics Data System (ADS)

    Eichenlaub, Jesse B.

    2005-03-01

    The difference in accommodation and convergence distance experienced when viewing stereoscopic displays has long been recognized as a source of visual discomfort. It is especially problematic in head mounted virtual reality and enhanced reality displays, where images must often be displayed across a large depth range or superimposed on real objects. DTI has demonstrated a novel method of creating stereoscopic images in which the focus and fixation distances are closely matched for all parts of the scene from close distances to infinity. The method is passive in the sense that it does not rely on eye tracking, moving parts, variable focus optics, vibrating optics, or feedback loops. The method uses a rapidly changing illumination pattern in combination with a high speed microdisplay to create cones of light that converge at different distances to form the voxels of a high resolution space filling image. A bench model display was built and a series of visual tests were performed in order to demonstrate the concept and investigate both its capabilities and limitations. Results proved conclusively that real optical images were being formed and that observers had to change their focus to read text or see objects at different distances

  19. Multifunctional millimeter-wave radar system for helicopter safety

    NASA Astrophysics Data System (ADS)

    Goshi, Darren S.; Case, Timothy J.; McKitterick, John B.; Bui, Long Q.

    2012-06-01

    A multi-featured sensor solution has been developed that enhances the operational safety and functionality of small airborne platforms, representing an invaluable stride toward enabling higher-risk, tactical missions. This paper demonstrates results from a recently developed multi-functional sensor system that integrates a high performance millimeter-wave radar front end, an evidence grid-based integration processing scheme, and the incorporation into a 3D Synthetic Vision System (SVS) display. The front end architecture consists of a w-band real-beam scanning radar that generates a high resolution real-time radar map and operates with an adaptable antenna architecture currently configured with an interferometric capability for target height estimation. The raw sensor data is further processed within an evidence grid-based integration functionality that results in high-resolution maps in the region surrounding the platform. Lastly, the accumulated radar results are displayed in a fully rendered 3D SVS environment integrated with local database information to provide the best representation of the surrounding environment. The integrated system concept will be discussed and initial results from an experimental flight test of this developmental system will be presented. Specifically, the forward-looking operation of the system demonstrates the system's ability to produce high precision terrain mapping with obstacle detection and avoidance capability, showcasing the system's versatility in a true operational environment.

  20. Front and rear projection autostereoscopic 3D displays based on lenticular sheets

    NASA Astrophysics Data System (ADS)

    Wang, Qiong-Hua; Zang, Shang-Fei; Qi, Lin

    2015-03-01

    A front projection autostereoscopic display is proposed. The display is composed of eight projectors and a 3D-imageguided screen which having a lenticular sheet and a retro-reflective diffusion screen. Based on the optical multiplexing and de-multiplexing, the optical functions of the 3D-image-guided screen are parallax image interlacing and viewseparating, which is capable of reconstructing 3D images without quality degradation from the front direction. The operating principle, optical design calculation equations and correction method of parallax images are given. A prototype of the front projection autostereoscopic display is developed, which enhances the brightness and 3D perceptions, and improves space efficiency. The performance of this prototype is evaluated by measuring the luminance and crosstalk distribution along the horizontal direction at the optimum viewing distance. We also propose a rear projection autostereoscopic display. The display consists of eight projectors, a projection screen, and two lenticular sheets. The operation principle and calculation equations are described in detail and the parallax images are corrected by means of homography. A prototype of the rear projection autostereoscopic display is developed. The normalized luminance distributions of viewing zones from the measurement are given. Results agree well with the designed values. The prototype presents high resolution and high brightness 3D images. The research has potential applications in some commercial entertainments and movies for the realistic 3D perceptions.

  1. Physical correction filter for improving the optical quality of an image

    NASA Technical Reports Server (NTRS)

    Lee, S. Y. (Inventor)

    1975-01-01

    A family of physical correction filters is described. Each filter is designed to correct image content of a photographed scene of limited resolution and includes a first filter element with a pinhole through which light passes to a differential amplifier. A second filter element through which light passes through one or more openings, whose geometric configuration is a function of the cause of the resolution loss included. The light, passing through the second filter element, is also supplied to the differential amplifier whose output is used to activate an optical display or recorder to reproduce a photograph or display of the scene in the original photograph or display of the scene in the original photograph with resolution which is significantly greater than that characterizing the original photograph.

  2. Three-dimensional laser microvision.

    PubMed

    Shimotahira, H; Iizuka, K; Chu, S C; Wah, C; Costen, F; Yoshikuni, Y

    2001-04-10

    A three-dimensional (3-D) optical imaging system offering high resolution in all three dimensions, requiring minimum manipulation and capable of real-time operation, is presented. The system derives its capabilities from use of the superstructure grating laser source in the implementation of a laser step frequency radar for depth information acquisition. A synthetic aperture radar technique was also used to further enhance its lateral resolution as well as extend the depth of focus. High-speed operation was made possible by a dual computer system consisting of a host and a remote microcomputer supported by a dual-channel Small Computer System Interface parallel data transfer system. The system is capable of operating near real time. The 3-D display of a tunneling diode, a microwave integrated circuit, and a see-through image taken by the system operating near real time are included. The depth resolution is 40 mum; lateral resolution with a synthetic aperture approach is a fraction of a micrometer and that without it is approximately 10 mum.

  3. Mini gamma camera, camera system and method of use

    DOEpatents

    Majewski, Stanislaw; Weisenberger, Andrew G.; Wojcik, Randolph F.

    2001-01-01

    A gamma camera comprising essentially and in order from the front outer or gamma ray impinging surface: 1) a collimator, 2) a scintillator layer, 3) a light guide, 4) an array of position sensitive, high resolution photomultiplier tubes, and 5) printed circuitry for receipt of the output of the photomultipliers. There is also described, a system wherein the output supplied by the high resolution, position sensitive photomultipiler tubes is communicated to: a) a digitizer and b) a computer where it is processed using advanced image processing techniques and a specific algorithm to calculate the center of gravity of any abnormality observed during imaging, and c) optional image display and telecommunications ports.

  4. High resolution image processing on low-cost microcomputers

    NASA Technical Reports Server (NTRS)

    Miller, R. L.

    1993-01-01

    Recent advances in microcomputer technology have resulted in systems that rival the speed, storage, and display capabilities of traditionally larger machines. Low-cost microcomputers can provide a powerful environment for image processing. A new software program which offers sophisticated image display and analysis on IBM-based systems is presented. Designed specifically for a microcomputer, this program provides a wide-range of functions normally found only on dedicated graphics systems, and therefore can provide most students, universities and research groups with an affordable computer platform for processing digital images. The processing of AVHRR images within this environment is presented as an example.

  5. High-Resolution Large-Field-of-View Three-Dimensional Hologram Display System and Method Thereof

    NASA Technical Reports Server (NTRS)

    Chao, Tien-Hsin (Inventor); Mintz, Frederick W. (Inventor); Tsou, Peter (Inventor); Bryant, Nevin A. (Inventor)

    2001-01-01

    A real-time, dynamic, free space-virtual reality, 3-D image display system is enabled by using a unique form of Aerogel as the primary display media. A preferred embodiment of this system comprises a 3-D mosaic topographic map which is displayed by fusing four projected hologram images. In this embodiment, four holographic images are projected from four separate holograms. Each holographic image subtends a quadrant of the 4(pi) solid angle. By fusing these four holographic images, a static 3-D image such as a featured terrain map would be visible for 360 deg in the horizontal plane and 180 deg in the vertical plane. An input, either acquired by 3-D image sensor or generated by computer animation, is first converted into a 2-D computer generated hologram (CGH). This CGH is then downloaded into large liquid crystal (LC) panel. A laser projector illuminates the CGH-filled LC panel and generates and displays a real 3-D image in the Aerogel matrix.

  6. Large depth of focus dynamic micro integral imaging for optical see-through augmented reality display using a focus-tunable lens.

    PubMed

    Shen, Xin; Javidi, Bahram

    2018-03-01

    We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.

  7. Digital Light Processing update: status and future applications

    NASA Astrophysics Data System (ADS)

    Hornbeck, Larry J.

    1999-05-01

    Digital Light Processing (DLP) projection displays based on the Digital Micromirror Device (DMD) were introduced to the market in 1996. Less than 3 years later, DLP-based projectors are found in such diverse applications as mobile, conference room, video wall, home theater, and large-venue. They provide high-quality, seamless, all-digital images that have exceptional stability as well as freedom from both flicker and image lag. Marked improvements have been made in the image quality of DLP-based projection display, including brightness, resolution, contrast ratio, and border image. DLP-based mobile projectors that weighted about 27 pounds in 1996 now weight only about 7 pounds. This weight reduction has been responsible for the definition of an entirely new projector class, the ultraportable. New applications are being developed for this important new projection display technology; these include digital photofinishing for high process speed minilab and maxilab applications and DLP Cinema for the digital delivery of films to audiences around the world. This paper describes the status of DLP-based projection display technology, including its manufacturing, performance improvements, and new applications, with emphasis on DLP Cinema.

  8. On-demand stereoscopic 3D displays for avionic and military applications

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri; Lu, Kanghua; Larson, Brent; Schmidt, John; Cupero, Frank

    2010-04-01

    High speed AM LCD flat panels are evaluated for use in Field Sequential Stereoscopic (FSS) 3D displays for military and avionic applications. A 120 Hz AM LCD is used in field-sequential mode for constructing eyewear-based as well as autostereoscopic 3D display demonstrators for test and evaluation. The COTS eyewear-based system uses shutter glasses to control left-eye/right-eye images. The autostereoscopic system uses a custom backlight to generate illuminating pupils for left and right eyes. It is driven in synchronization with the images on the LCD. Both displays provide 3D effect in full-color and full-resolution in the AM LCD flat panel. We have realized luminance greater than 200 fL in 3D mode with the autostereoscopic system for sunlight readability. The characterization results and performance attributes of both systems are described.

  9. Practical low-cost stereo head-mounted display

    NASA Astrophysics Data System (ADS)

    Pausch, Randy; Dwivedi, Pramod; Long, Allan C., Jr.

    1991-08-01

    A high-resolution head-mounted display has been developed from substantially cheaper components than previous systems. Monochrome displays provide 720 by 280 monochrome pixels to each eye in a one-inch-square region positioned approximately one inch from each eye. The display hardware is the Private Eye, manufactured by Reflection Technologies, Inc. The tracking system uses the Polhemus Isotrak, providing (x,y,z, azimuth, elevation and roll) information on the user''s head position and orientation 60 times per second. In combination with a modified Nintendo Power Glove, this system provides a full-functionality virtual reality/simulation system. Using two host 80386 computers, real-time wire frame images can be produced. Other virtual reality systems require roughly 250,000 in hardware, while this one requires only 5,000. Stereo is particularly useful for this system because shading or occlusion cannot be used as depth cues.

  10. Demonstration of arbitrary views based on autostereoscopic three-dimensional display system

    NASA Astrophysics Data System (ADS)

    Liu, Boyang; Sang, Xinzhu; Yu, Xunbo; Li, Liu; Yang, Le; Yan, Binbin; Wang, Kuiru; Yu, Chongxiu

    2017-10-01

    A method to realize arbitrary views for the lenticular lens array based on autostereoscopic three-dimensional display system is demonstrated. Normally, the number of views is proportional to pitch of the lenticular lens array. Increasing the number of views will result in reducing resolution and enhancing of granular sensation. 32 dense views can be achieved with one lenticular lens pitch covering 5.333 sub-pixels, which does significantly increases the number of views without affecting the resolution. But the structure of pitch and the number of views are fixed. Here, the 3D display method that the number of views can be changed artificially for most structures of lenticular lens is presented. Compared with the previous 32 views display method, the smoothness of motion parallex and the display depth of field are significantly improved.

  11. Hybrid diffractive-refractive optical system design of head-mounted display for augmented reality

    NASA Astrophysics Data System (ADS)

    Zhang, Huijuan

    2005-02-01

    An optical see-through head-mounted display for augmented reality is designed in this paper. Considering the factors, such as the optical performance, the utilization ratios of energy of real world and virtual world, the feelings of users when he wears it and etc., a structure of the optical see-through is adopted. With the characteristics of the particular negative dispersive and the power of realizing random-phase modulation, the diffractive surface is helpful for optical system of reducing weight, simplifying structure and etc., and a diffractive surface is introduced in our optical system. The optical system with 25 mm eye relief, 12 mm exit pupil and 20° (H)x15.4° (V) field-of-view is designed. The utilization ratios of energy of real world and virtual world are 1/4 and 1/2, respectively. The angular resolution of display is 0.27 mrad and it less than that of the minimum of human eyes. The diameter of this system is less than 46mm, and it applies the binocular. This diffractive-refractive optical system of see-through head-mounted display not only satisfies the demands of user"s factors in structure, but also with high resolution, very small chromatic aberration and distortion, and satisfies the need of augmented reality. In the end, the parameters of the diffractive surface are discussed.

  12. The Sharjah Center for Astronomy and Space Sciences (SCASS 2015): Concept and Resources

    NASA Astrophysics Data System (ADS)

    Naimiy, Hamid M. K. Al

    2015-08-01

    The Sharjah Center for Astronomy and Space Sciences (SCASS) was launched this year 2015 at the University of Sharjah in the UAE. The center will serve to enrich research in the fields of astronomy and space sciences, promote these fields at all educational levels, and encourage community involvement in these sciences. SCASS consists of:The Planetarium: Contains a semi-circle display screen (18 meters in diameter) installed at an angle of 10° which displays high-definition images using an advanced digital display system consisting of seven (7) high-performance light-display channels. The Planetarium Theatre offers a 200-seat capacity with seats placed at highly calculated angles. The Planetarium also contains an enormous star display (Star Ball - 10 million stars) located in the heart of the celestial dome theatre.The Sharjah Astronomy Observatory: A small optical observatory consisting of a reflector telescope 45 centimeters in diameter to observe the galaxies, stars and planets. Connected to it is a refractor telescope of 20 centimeters in diameter to observe the sun and moon with highly developed astronomical devices, including a digital camera (CCD) and a high-resolution Echelle Spectrograph with auto-giving and remote calibration ports.Astronomy, space and physics educational displays for various age groups include:An advanced space display that allows for viewing the universe during four (4) different time periods as seen by:1) The naked eye; 2) Galileo; 3) Spectrographic technology; and 4) The space technology of today.A space technology display that includes space discoveries since the launching of the first satellite in 1940s until now.The Design Concept for the Center (450,000 sq. meters) was originated by HH Sheikh Sultan bin Mohammed Al Qasimi, Ruler of Sharjah, and depicts the dome as representing the sun in the middle of the center surrounded by planetary bodies in orbit to form the solar system as seen in the sky.

  13. User-Centered Design Driven Development of a Virtual Reality Therapy Application for Iraq War Combat-Related Post Traumatic Stress Disorder

    DTIC Science & Technology

    2006-09-01

    application with the aim of finding an affordable display with acceptable resolution and field of view (5DT, Cyvisor, eMagin ). The HMD that was chosen was the... eMagin z800, which contains OLED displays capable of 800x600 (SVGA) resolution with a 40 degree diagonal field of view (http://www.emagin.com

  14. Controller response to conflict resolution advisory

    DOT National Transportation Integrated Search

    1992-12-01

    Conflict Resolution Advisory (CRA) is an automated software aid for air traffic control specialists at air route traffic control centers (ARTCCs). CRA calculates, validates, and displays to the en route controller a single resolution for predicted se...

  15. Controller Response to Conflict Resolution Advisory

    DOT National Transportation Integrated Search

    1992-12-01

    Conflict Resolution Advisory (CRA) is an automated software aid for air traffic : control specialists at air route traffic control centers (ARTCCs). CRA calculates, : validates, and displays to the en route controller a single resolution for predicte...

  16. Controller Response to Conflict Resolution Advisory Prototype

    DOT National Transportation Integrated Search

    1991-01-01

    Conflict Resolution Advisory (CRA) is an automated software aid for air traffic : control specialists at air route traffic control centers (ARTCCs). CRA calculates, : validates, and displays to the en route controller a single resolution for predicte...

  17. Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yu, E-mail: yuzhang@smu.edu.cn, E-mail: qianjinfeng08@gmail.com; Wu, Xiuxiu; Yang, Wei

    2014-11-01

    Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images.more » The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.« less

  18. Three-Dimensional Media Technologies: Potentials for Study in Visual Literacy.

    ERIC Educational Resources Information Center

    Thwaites, Hal

    This paper presents an overview of three-dimensional media technologies (3Dmt). Many of the new 3Dmt are the direct result of interactions of computing, communications, and imaging technologies. Computer graphics are particularly well suited to the creation of 3D images due to the high resolution and programmable nature of the current displays.…

  19. New portable FELIX 3D display

    NASA Astrophysics Data System (ADS)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  20. Spatially detailed retrievals of spring phenology from single-season high-resolution image time series

    NASA Astrophysics Data System (ADS)

    Vrieling, Anton; Skidmore, Andrew K.; Wang, Tiejun; Meroni, Michele; Ens, Bruno J.; Oosterbeek, Kees; O'Connor, Brian; Darvishzadeh, Roshanak; Heurich, Marco; Shepherd, Anita; Paganini, Marc

    2017-07-01

    Vegetation indices derived from satellite image time series have been extensively used to estimate the timing of phenological events like season onset. Medium spatial resolution (≥250 m) satellite sensors with daily revisit capability are typically employed for this purpose. In recent years, phenology is being retrieved at higher resolution (≤30 m) in response to increasing availability of high-resolution satellite data. To overcome the reduced acquisition frequency of such data, previous attempts involved fusion between high- and medium-resolution data, or combinations of multi-year acquisitions in a single phenological reconstruction. The objectives of this study are to demonstrate that phenological parameters can now be retrieved from single-season high-resolution time series, and to compare these retrievals against those derived from multi-year high-resolution and single-season medium-resolution satellite data. The study focuses on the island of Schiermonnikoog, the Netherlands, which comprises a highly-dynamic saltmarsh, dune vegetation, and agricultural land. Combining NDVI series derived from atmospherically-corrected images from RapidEye (5 m-resolution) and the SPOT5 Take5 experiment (10m-resolution) acquired between March and August 2015, phenological parameters were estimated using a function fitting approach. We then compared results with phenology retrieved from four years of 30 m Landsat 8 OLI data, and single-year 100 m Proba-V and 250 m MODIS temporal composites of the same period. Retrieved phenological parameters from combined RapidEye/SPOT5 displayed spatially consistent results and a large spatial variability, providing complementary information to existing vegetation community maps. Retrievals that combined four years of Landsat observations into a single synthetic year were affected by the inclusion of years with warmer spring temperatures, whereas adjustment of the average phenology to 2015 observations was only feasible for a few pixels due to cloud cover around phenological transition dates. The Proba-V and MODIS phenology retrievals scaled poorly relative to their high-resolution equivalents, indicating that medium-resolution phenology retrievals need to be interpreted with care, particularly in landscapes with fine-scale land cover variability.

  1. High resolution reversible color images on photonic crystal substrates.

    PubMed

    Kang, Pilgyu; Ogunbo, Samuel O; Erickson, David

    2011-08-16

    When light is incident on a crystalline structure with appropriate periodicity, some colors will be preferentially reflected (Joannopoulos, J. D.; Meade, R. D.; Winn, J. N. Photonic crystals: molding the flow of light; Princeton University Press: Princeton, NJ, 1995; p ix, 137 pp). These photonic crystals and the structural color they generate represent an interesting method for creating reflective displays and drawing devices, since they can achieve a continuous color response and do not require back lighting (Joannopoulos, J. D.; Villeneuve, P. R.; Fan, S. H. Photonic crystals: Putting a new twist on light. Nature 1997, 386, 143-149; Graham-Rowe, D. Tunable structural colour. Nat. Photonics 2009, 3, 551-553.; Arsenault, A. C.; Puzzo, D. P.; Manners, I.; Ozin, G. A. Photonic-crystal full-colour displays. Nat. Photonics 2007, 1, 468-472; Walish, J. J.; Kang, Y.; Mickiewicz, R. A.; Thomas, E. L. Bioinspired Electrochemically Tunable Block Copolymer Full Color Pixels. Adv. Mater.2009, 21, 3078). Here we demonstrate a technique for creating erasable, high-resolution, color images using otherwise transparent inks on self-assembled photonic crystal substrates (Fudouzi, H.; Xia, Y. N. Colloidal crystals with tunable colors and their use as photonic papers. Langmuir 2003, 19, 9653-9660). Using inkjet printing, we show the ability to infuse fine droplets of silicone oils into the crystal, locally swelling it and changing the reflected color (Sirringhaus, H.; Kawase, T.; Friend, R. H.; Shimoda, T.; Inbasekaran, M.; Wu, W.; Woo, E. P. High-resolution inkjet printing of all-polymer transistor circuits. Science 2000, 290, 2123-2126). Multicolor images with resolutions as high as 200 μm are obtained from oils of different molecular weights with the lighter oils being able to penetrate deeper, yielding larger red shifts. Erasing of images is done simply by adding a low vapor pressure oil which dissolves the image, returning the substrate to its original state.

  2. A study of ten quasars with redshifts greater than four

    NASA Technical Reports Server (NTRS)

    Schneider, Donald P.; Schmidt, Maarten; Gunn, James E.

    1989-01-01

    Four quasars with redshifts greater than four were detected in a low-resolution CCD grism survey. CCD photometry and high S/N, moderate resolution spectra are presented for these quasars and the six other known quasars with redshifts above 4. The M sub B values of nine of the objects are between -27.5 and -25, with the tenth quasar having an M sub B value of -29. The emission lines and shapes of the continua of these ten quasars are similar to those of lower-redshift quasars. The results suggest that the C IV emission lines in high-redshift quasars may be weaker than those in lower-redshift quasars. The continua of all of the high-redshift quasars display strong depressions blueward of the Ly-alpha emission line.

  3. Mate choice in the eye and ear of the beholder? Female multimodal sensory configuration influences her preferences.

    PubMed

    Ronald, Kelly L; Fernández-Juricic, Esteban; Lucas, Jeffrey R

    2018-05-16

    A common assumption in sexual selection studies is that receivers decode signal information similarly. However, receivers may vary in how they rank signallers if signal perception varies with an individual's sensory configuration. Furthermore, receivers may vary in their weighting of different elements of multimodal signals based on their sensory configuration. This could lead to complex levels of selection on signalling traits. We tested whether multimodal sensory configuration could affect preferences for multimodal signals. We used brown-headed cowbird ( Molothrus ater ) females to examine how auditory sensitivity and auditory filters, which influence auditory spectral and temporal resolution, affect song preferences, and how visual spatial resolution and visual temporal resolution, which influence resolution of a moving visual signal, affect visual display preferences. Our results show that multimodal sensory configuration significantly affects preferences for male displays: females with better auditory temporal resolution preferred songs that were shorter, with lower Wiener entropy, and higher frequency; and females with better visual temporal resolution preferred males with less intense visual displays. Our findings provide new insights into mate-choice decisions and receiver signal processing. Furthermore, our results challenge a long-standing assumption in animal communication which can affect how we address honest signalling, assortative mating and sensory drive. © 2018 The Author(s).

  4. An Evaluation of Stereoscopic Digital Mammography for Earlier Detection of Breast Cancer and Reduced Rate of Recall

    DTIC Science & Technology

    2004-08-01

    on a pair of high -resolution, LCD medical monitors. The change to the new workstation has required us to rewrite the software... In the original CRT-based system, the two 7 images forming a stereo pair were displayed alternately on the same CRT face, at a high frame rate (120 Hz...then, separately, receive the stereo screening exam on the research GE digital mammography unit.

  5. Conflict resolution patterns and longevity of adolescent romantic couples: a 2-year follow-up study.

    PubMed

    Shulman, Shmuel; Tuval-Mashiach, Rivka; Levran, Elisheva; Anbar, Shmuel

    2006-08-01

    This study examined the predictors of longevity among 40 late adolescent romantic couples (mean age males=17.71 years; mean age females=17.18 years). Subjects were given a revealed differences task where they were asked to solve their disagreements. The joint task was recorded, transcribed and analysed by two raters. At 3, 6, 9, 12, 18, and 24 months after this procedure, partners were contacted by telephone and asked whether their relationship was still intact. A cluster analysis was performed on couples' interaction indices and yielded three distinctive conflict resolution patterns. The Downplaying pattern was characterized by a high tendency to minimize the conflict. The relationships of the adolescents displaying this pattern stayed intact for a period of 9 months. Half of them were still together after 24 months. The adolescents displaying the Integrative pattern, which shows a good ability to negotiate differences tended to stay together over a period of 24 months. Those showing the Conflictive pattern, characterized by a confrontative interaction, were separated by the 3 months follow-up. Results are discussed within the context of developmental perspectives of conflict resolution tendencies and adolescent romance.

  6. Engineering the Ideal Gigapixel Image Viewer

    NASA Astrophysics Data System (ADS)

    Perpeet, D. Wassenberg, J.

    2011-09-01

    Despite improvements in automatic processing, analysts are still faced with the task of evaluating gigapixel-scale mosaics or images acquired by telescopes such as Pan-STARRS. Displaying such images in ‘ideal’ form is a major challenge even today, and the amount of data will only increase as sensor resolutions improve. In our opinion, the ideal viewer has several key characteristics. Lossless display - down to individual pixels - ensures all information can be extracted from the image. Support for all relevant pixel formats (integer or floating point) allows displaying data from different sensors. Smooth zooming and panning in the high-resolution data enables rapid screening and navigation in the image. High responsiveness to input commands avoids frustrating delays. Instantaneous image enhancement, e.g. contrast adjustment and image channel selection, helps with analysis tasks. Modest system requirements allow viewing on regular workstation computers or even laptops. To the best of our knowledge, no such software product is currently available. Meeting these goals requires addressing certain realities of current computer architectures. GPU hardware accelerates rendering and allows smooth zooming without high CPU load. Programmable GPU shaders enable instant channel selection and contrast adjustment without any perceptible slowdown or changes to the input data. Relatively low disk transfer speeds suggest the use of compression to decrease the amount of data to transfer. Asynchronous I/O allows decompressing while waiting for previous I/O operations to complete. The slow seek times of magnetic disks motivate optimizing the order of the data on disk. Vectorization and parallelization allow significant increases in computational capacity. Limited memory requires streaming and caching of image regions. We develop a viewer that takes the above issues into account. Its awareness of the computer architecture enables previously unattainable features such as smooth zooming and image enhancement within high-resolution data. We describe our implementation, disclosing its novel file format and lossless image codec whose decompression is faster than copying the raw data in memory. Both provide crucial performance boosts compared to conventional approaches. Usability tests demonstrate the suitability of our viewer for rapid analysis of large SAR datasets, multispectral satellite imagery and mosaics.

  7. Quantitative evaluation of three advanced laparoscopic viewing technologies: a stereo endoscope, an image projection display, and a TFT display.

    PubMed

    Wentink, M; Jakimowicz, J J; Vos, L M; Meijer, D W; Wieringa, P A

    2002-08-01

    Compared to open surgery, minimally invasive surgery (MIS) relies heavily on advanced technology, such as endoscopic viewing systems and innovative instruments. The aim of the study was to objectively compare three technologically advanced laparoscopic viewing systems with the standard viewing system currently used in most Dutch hospitals. We evaluated the following advanced laparoscopic viewing systems: a Thin Film Transistor (TFT) display, a stereo endoscope, and an image projection display. The standard viewing system was comprised of a monocular endoscope and a high-resolution monitor. Task completion time served as the measure of performance. Eight surgeons with laparoscopic experience participated in the experiment. The average task time was significantly greater (p <0.05) with the stereo viewing system than with the standard viewing system. The average task times with the TFT display and the image projection display did not differ significantly from the standard viewing system. Although the stereo viewing system promises improved depth perception and the TFT and image projection displays are supposed to improve hand-eye coordination, none of these systems provided better task performance than the standard viewing system in this pelvi-trainer experiment.

  8. HDTV and large-screen display

    NASA Astrophysics Data System (ADS)

    Mitsuhashi, Tetsuo

    1990-08-01

    HDTV (known as Hi-Vision in Japan), with its ability to provide through high- definition pictures on a large screen display advanced psychological effects such as sensations of reality and a visual impact unobtainable in conventional television, is the television system of the next generation. In Japan, daily one-hour experimental broadcasting was initiated in June 1989 using the BS-2 broadcast satellite, and regular service is scheduled to begin via the BS-3 satellite to be launched in 1990. To this end, a home-use receiver using VLSIs has already been developed. Moreover, HDTV is currently being applied in such diverse areas as film production, printing and publishing, medicine, and art museums. The HDTV system handles approximately five times the information of conventional television. As a result, a large screen display capable of maintaining stable resolution greater than twice that of conventional displays is essential to the full realization of HDTV's vast potential. This paper will first discuss HDTV's basic parameters, concentrating on the psychovisual effects, and explain some preferable display characteristics from this psychovisual point of view. It will then discuss the technical problems in developing such a display, and final ly describe the current state of HDTV display development.

  9. Rare-metal-free high-performance Ga-Sn-O thin film transistor

    NASA Astrophysics Data System (ADS)

    Matsuda, Tokiyoshi; Umeda, Kenta; Kato, Yuta; Nishimoto, Daiki; Furuta, Mamoru; Kimura, Mutsumi

    2017-03-01

    Oxide semiconductors have been investigated as channel layers for thin film transistors (TFTs) which enable next-generation devices such as high-resolution liquid crystal displays (LCDs), organic light emitting diode (OLED) displays, flexible electronics, and innovative devices. Here, high-performance and stable Ga-Sn-O (GTO) TFTs were demonstrated for the first time without the use of rare metals such as In. The GTO thin films were deposited using radiofrequency (RF) magnetron sputtering. A high field effect mobility of 25.6 cm2/Vs was achieved, because the orbital structure of Sn was similar to that of In. The stability of the GTO TFTs was examined under bias, temperature, and light illumination conditions. The electrical behaviour of the GTO TFTs was more stable than that of In-Ga-Zn-O (IGZO) TFTs, which was attributed to the elimination of weak Zn-O bonds.

  10. Rare-metal-free high-performance Ga-Sn-O thin film transistor

    PubMed Central

    Matsuda, Tokiyoshi; Umeda, Kenta; Kato, Yuta; Nishimoto, Daiki; Furuta, Mamoru; Kimura, Mutsumi

    2017-01-01

    Oxide semiconductors have been investigated as channel layers for thin film transistors (TFTs) which enable next-generation devices such as high-resolution liquid crystal displays (LCDs), organic light emitting diode (OLED) displays, flexible electronics, and innovative devices. Here, high-performance and stable Ga-Sn-O (GTO) TFTs were demonstrated for the first time without the use of rare metals such as In. The GTO thin films were deposited using radiofrequency (RF) magnetron sputtering. A high field effect mobility of 25.6 cm2/Vs was achieved, because the orbital structure of Sn was similar to that of In. The stability of the GTO TFTs was examined under bias, temperature, and light illumination conditions. The electrical behaviour of the GTO TFTs was more stable than that of In-Ga-Zn-O (IGZO) TFTs, which was attributed to the elimination of weak Zn-O bonds. PMID:28290547

  11. Rare-metal-free high-performance Ga-Sn-O thin film transistor.

    PubMed

    Matsuda, Tokiyoshi; Umeda, Kenta; Kato, Yuta; Nishimoto, Daiki; Furuta, Mamoru; Kimura, Mutsumi

    2017-03-14

    Oxide semiconductors have been investigated as channel layers for thin film transistors (TFTs) which enable next-generation devices such as high-resolution liquid crystal displays (LCDs), organic light emitting diode (OLED) displays, flexible electronics, and innovative devices. Here, high-performance and stable Ga-Sn-O (GTO) TFTs were demonstrated for the first time without the use of rare metals such as In. The GTO thin films were deposited using radiofrequency (RF) magnetron sputtering. A high field effect mobility of 25.6 cm 2 /Vs was achieved, because the orbital structure of Sn was similar to that of In. The stability of the GTO TFTs was examined under bias, temperature, and light illumination conditions. The electrical behaviour of the GTO TFTs was more stable than that of In-Ga-Zn-O (IGZO) TFTs, which was attributed to the elimination of weak Zn-O bonds.

  12. High performance interactive graphics for shower reconstruction in HPC, the DELPHI barrel electromagnetic calorimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stanescu, C.

    1990-08-01

    Complex software for shower reconstruction in DELPHI barrel electromagnetic calorimeter which deals, for each event, with great amounts of information, due to the high spatial resolution of this detector, needs powerful verification tools. An interactive graphics program, running on high performance graphics display system Whizzard 7555 from Megatek, was developed to display the logical steps in showers and their axes reconstruction. The program allows both operations on the image in real-time (rotation, translation and zoom) and the use of non-geometrical criteria to modify it (as the use of energy) thresholds for the representation of the elements that compound the showersmore » (or of the associated lego plots). For this purpose graphics objects associated to user parameters were defined. Instancing and modelling features of the native graphics library were extensively used.« less

  13. Application of the Lucy–Richardson Deconvolution Procedure to High Resolution Photoemission Spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rameau, J.; Yang, H.-B.; Johnson, P.D.

    2010-07-01

    Angle-resolved photoemission has developed into one of the leading probes of the electronic structure and associated dynamics of condensed matter systems. As with any experimental technique the ability to resolve features in the spectra is ultimately limited by the resolution of the instrumentation used in the measurement. Previously developed for sharpening astronomical images, the Lucy-Richardson deconvolution technique proves to be a useful tool for improving the photoemission spectra obtained in modern hemispherical electron spectrometers where the photoelectron spectrum is displayed as a 2D image in energy and momentum space.

  14. WE-D-204-02: Novel Method for Correcting Degradation of Sharpness of Liquid-Crystal Display Based On Modulation Transfer Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokurei, S; Department of Radiology, Yamaguchi University Hospital, Ube, Yamaguchi; Morishita, J

    2015-06-15

    Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters weremore » computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.« less

  15. Immersive telepresence system using high-resolution omnidirectional movies and a locomotion interface

    NASA Astrophysics Data System (ADS)

    Ikeda, Sei; Sato, Tomokazu; Kanbara, Masayuki; Yokoya, Naokazu

    2004-05-01

    Technology that enables users to experience a remote site virtually is called telepresence. A telepresence system using real environment images is expected to be used in the field of entertainment, medicine, education and so on. This paper describes a novel telepresence system which enables users to walk through a photorealistic virtualized environment by actual walking. To realize such a system, a wide-angle high-resolution movie is projected on an immersive multi-screen display to present users the virtualized environments and a treadmill is controlled according to detected user's locomotion. In this study, we use an omnidirectional multi-camera system to acquire images real outdoor scene. The proposed system provides users with rich sense of walking in a remote site.

  16. Photolithographic patterning of vacuum-deposited organic light emitting devices

    NASA Astrophysics Data System (ADS)

    Tian, P. F.; Burrows, P. E.; Forrest, S. R.

    1997-12-01

    We demonstrate a photolithographic technique to fabricate vacuum-deposited organic light emitting devices. Photoresist liftoff combined with vertical deposition of the emissive organic materials and the metal cathode, followed by oblique deposition of a metal cap, avoids the use of high processing temperatures and the exposure of the organic materials to chemical degradation. The unpackaged devices show no sign of deterioration in room ambient when compared with conventional devices fabricated using low-resolution, shadow mask patterning. Furthermore, the devices are resistant to rapid degradation when operated in air for extended periods. This work illustrates a potential foundation for the volume production of very high-resolution, full color, flat panel displays based on small molecular weight organic light emitting devices.

  17. Terrain Portrayal for Synthetic Vision Systems Head-Down Displays Evaluation Results

    NASA Technical Reports Server (NTRS)

    Hughes, Monica F.; Glaab, Louis J.

    2007-01-01

    A critical component of SVS displays is the appropriate presentation of terrain to the pilot. At the time of this study, the relationship between the complexity of the terrain presentation and resulting enhancements of pilot SA and pilot performance had been largely undefined. The terrain portrayal for SVS head-down displays (TP-HDD) simulation examined the effects of two primary elements of terrain portrayal on the primary flight display (PFD): variations of digital elevation model (DEM) resolution and terrain texturing. Variations in DEM resolution ranged from sparsely spaced (30 arc-sec) to very closely spaced data (1 arc-sec). Variations in texture involved three primary methods: constant color, elevation-based generic, and photo-realistic, along with a secondary depth cue enhancer in the form of a fishnet grid overlay.

  18. Networks for image acquisition, processing and display

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J., Jr.

    1990-01-01

    The human visual system comprises layers of networks which sample, process, and code images. Understanding these networks is a valuable means of understanding human vision and of designing autonomous vision systems based on network processing. Ames Research Center has an ongoing program to develop computational models of such networks. The models predict human performance in detection of targets and in discrimination of displayed information. In addition, the models are artificial vision systems sharing properties with biological vision that has been tuned by evolution for high performance. Properties include variable density sampling, noise immunity, multi-resolution coding, and fault-tolerance. The research stresses analysis of noise in visual networks, including sampling, photon, and processing unit noises. Specific accomplishments include: models of sampling array growth with variable density and irregularity comparable to that of the retinal cone mosaic; noise models of networks with signal-dependent and independent noise; models of network connection development for preserving spatial registration and interpolation; multi-resolution encoding models based on hexagonal arrays (HOP transform); and mathematical procedures for simplifying analysis of large networks.

  19. Language in context: Characterizing the comprehension of referential expressions with MEG.

    PubMed

    Brodbeck, Christian; Pylkkänen, Liina

    2017-02-15

    A critical component of comprehending language in context is identifying the entities that individual linguistic expressions refer to. While previous research has shown that language comprehenders resolve reference quickly and incrementally, little is currently known about the neural basis of successful reference resolution. Using source localized MEG, we provide evidence across 3 experiments and 2 languages that successful reference resolution in simple visual displays is associated with increased activation in the medial parietal lobe. In each trial, participants saw a simple visual display containing three objects which constituted the referential domain. Target referential expressions were embedded in questions about the displays. By varying the displays, we manipulated referential status while keeping the linguistic expressions constant. Follow-up experiments addressed potential interactions of reference resolution with linguistic predictiveness and pragmatic plausibility. Notably, we replicated the effect in Arabic, a language that differs in a structurally informative way from English while keeping referential aspects parallel to our two English studies. Distributed minimum norm estimates of MEG data consistently indicated that reference resolution is associated with increased activity in the medial parietal lobe. With one exception, the timing of the onset of the medial parietal response fell into a mid-latency time-window at 350-500ms after the onset of the resolving word. Through concurrent EEG recordings on a subset of subjects we also describe the EEG topography of the effect of reference resolution, which makes the result available for comparison with a larger existing literature. Our results extend previous reports that medial parietal lobe is involved in referential language processing, indicating that it is relevant for reference resolution to individual referents, and suggests avenues for future research. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Spectral analysis of views interpolated by chroma subpixel downsampling for 3D autosteroscopic displays

    NASA Astrophysics Data System (ADS)

    Marson, Avishai; Stern, Adrian

    2015-05-01

    One of the main limitations of horizontal parallax autostereoscopic displays is the horizontal resolution loss due the need to repartition the pixels of the display panel among the multiple views. Recently we have shown that this problem can be alleviated by applying a color sub-pixel rendering technique1. Interpolated views are generated by down-sampling the panel pixels at sub-pixel level, thus increasing the number of views. The method takes advantage of lower acuity of the human eye to chromatic resolution. Here we supply further support of the technique by analyzing the spectra of the subsampled images.

  1. From Video to Photo

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Ever wonder whether a still shot from a home video could serve as a "picture perfect" photograph worthy of being framed and proudly displayed on the mantle? Wonder no more. A critical imaging code used to enhance video footage taken from spaceborne imaging instruments is now available within a portable photography tool capable of producing an optimized, high-resolution image from multiple video frames.

  2. VID-R and SCAN: Tools and Methods for the Automated Analysis of Visual Records.

    ERIC Educational Resources Information Center

    Ekman, Paul; And Others

    The VID-R (Visual Information Display and Retrieval) system that enables computer-aided analysis of visual records is composed of a film-to-television chain, two videotape recorders with complete remote control of functions, a video-disc recorder, three high-resolution television monitors, a teletype, a PDP-8, a video and audio interface, three…

  3. Procurement specification color graphic camera system

    NASA Technical Reports Server (NTRS)

    Prow, G. E.

    1980-01-01

    The performance and design requirements for a Color Graphic Camera System are presented. The system is a functional part of the Earth Observation Department Laboratory System (EODLS) and will be interfaced with Image Analysis Stations. It will convert the output of a raster scan computer color terminal into permanent, high resolution photographic prints and transparencies. Images usually displayed will be remotely sensed LANDSAT imager scenes.

  4. Freedom to Hate: Weighing First Amendment Rights against School Violence--A Case Study

    ERIC Educational Resources Information Center

    Kaplan, H. Roy

    2007-01-01

    River Run High School, located in rural west central Florida, was the site for a case study of student conflict precipitated by the wearing and display of Confederate flags on campus. Following a series of tense student encounters over Confederate and other racist symbols, a conflict resolution team was invited to intervene. Team members created a…

  5. An Undergraduate Endeavor: Assembling a Live Planetarium Show About Mars

    NASA Astrophysics Data System (ADS)

    McGraw, Allison M.

    2016-10-01

    Viewing the mysterious red planet Mars goes back thousands of years with just the human eye but in more recent years the growth of telescopes, satellites and lander missions unveil unrivaled detail of the Martian surface that tells a story worth listening to. This planetarium show will go through the observations starting with the ancients to current understandings of the Martian surface, atmosphere and inner-workings through past and current Mars missions. Visual animations of its planetary motions, display of high resolution images from the Hi-RISE (High Resolution Imaging Science Experiment) and CTX (Context Camera) data imagery aboard the MRO (Mars Reconnaissance Orbiter) as well as other datasets will be used to display the terrain detail and imagery of the planet Mars with a digital projection system. Local planetary scientists and Mars specialists from the Lunar and Planetary Lab at the University of Arizona (Tucson, AZ) will be interviewed and used in the show to highlight current technology and understandings of the red planet. This is an undergraduate project that is looking for collaborations and insight in order gain structure in script writing that will teach about this planetary body to all ages in the format of a live planetarium show.

  6. Mpeg2 codec HD improvements with medical and robotic imaging benefits

    NASA Astrophysics Data System (ADS)

    Picard, Wayne F. J.

    2010-02-01

    In this report, we propose an efficient scheme to use High Definition Television (HDTV) in a console or notebook format as a computer terminal in addition to their role as TV display unit. In the proposed scheme, we assume that the main computer is situated at a remote location. The computer raster in the remote server is compressed using an HD E- >Mpeg2 encoder and transmitted to the terminal at home. The built-in E->Mpeg2 decoder in the terminal decompresses the compressed bit stream, and displays the raster. The terminal will be fitted with a mouse and keyboard, through which the interaction with the remote computer server can be performed via a communications back channel. The terminal in a notebook format can thus be used as a high resolution computer and multimedia device. We will consider developments such as the required HD enhanced Mpeg2 resolution (E->Mpeg2) and its medical ramifications due to improvements on compressed image quality with 2D to 3D conversion (Mpeg3) and using the compressed Discrete Cosine Transform coefficients in the reality compression of vision and control of medical robotic surgeons.

  7. The Unidata Integrated Data Viewer

    NASA Astrophysics Data System (ADS)

    Weber, W. J.; Ho, Y.

    2016-12-01

    The Unidata Integrated Data Viewer (IDV) is a free and open source, virtual globe, software application that enables three dimensional viewing of earth science data. The Unidata IDV is data agnostic and can display and analyze disparate data in a single view. This capability facilitates cross discipline research and allows for multiple observation platforms to be displayed simultaneously for any given event. The Unidata IDV is a mature application, written in JAVA, and has been serving the earth science community for over 15 years. This demonstration will focus on near real time global satelliteobservations, the integration of the COSMIC radio occultation data set that profiles the atmosphere, and high resolution numerical weather prediction.

  8. Evaluation of a single-pixel one-transistor active pixel sensor for fingerprint imaging

    NASA Astrophysics Data System (ADS)

    Xu, Man; Ou, Hai; Chen, Jun; Wang, Kai

    2015-08-01

    Since it first appeared in iPhone 5S in 2013, fingerprint identification (ID) has rapidly gained popularity among consumers. Current fingerprint-enabled smartphones unanimously consists of a discrete sensor to perform fingerprint ID. This architecture not only incurs higher material and manufacturing cost, but also provides only static identification and limited authentication. Hence as the demand for a thinner, lighter, and more secure handset grows, we propose a novel pixel architecture that is a photosensitive device embedded in a display pixel and detects the reflected light from the finger touch for high resolution, high fidelity and dynamic biometrics. To this purpose, an amorphous silicon (a-Si:H) dual-gate photo TFT working in both fingerprint-imaging mode and display-driving mode will be developed.

  9. Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system

    NASA Astrophysics Data System (ADS)

    Luo, Wei; Marks, Daniel L.; Ralston, Tyler S.; Boppart, Stephen A.

    2006-03-01

    Optical coherence tomography (OCT) is an emerging high-resolution real-time biomedical imaging technology that has potential as a novel investigational tool in developmental biology and functional genomics. In this study, murine embryos and embryonic hearts are visualized with an OCT system capable of 2-µm axial and 15-µm lateral resolution and with real-time acquisition rates. We present, to our knowledge, the first sets of high-resolution 2- and 3-D OCT images that reveal the internal structures of the mammalian (murine) embryo (E10.5) and embryonic (E14.5 and E17.5) cardiovascular system. Strong correlations are observed between OCT images and corresponding hematoxylin- and eosin-stained histological sections. Real-time in vivo embryonic (E10.5) heart activity is captured by spectral-domain optical coherence tomography, processed, and displayed at a continuous rate of five frames per second. With the ability to obtain not only high-resolution anatomical data but also functional information during cardiovascular development, the OCT technology has the potential to visualize and quantify changes in murine development and in congenital and induced heart disease, as well as enable a wide range of basic in vitro and in vivo research studies in functional genomics.

  10. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles

    NASA Astrophysics Data System (ADS)

    Burgess, M. T.; Apostolakis, I.; Konofagou, E. E.

    2018-03-01

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  11. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.

    PubMed

    Burgess, M T; Apostolakis, I; Konofagou, E E

    2018-03-15

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  12. Design of a single projector multiview 3D display system

    NASA Astrophysics Data System (ADS)

    Geng, Jason

    2014-03-01

    Multiview three-dimensional (3D) display is able to provide horizontal parallax to viewers with high-resolution and fullcolor images being presented to each view. Most multiview 3D display systems are designed and implemented using multiple projectors, each generating images for one view. Although this multi-projector design strategy is conceptually straightforward, implementation of such multi-projector design often leads to a very expensive system and complicated calibration procedures. Even for a multiview system with a moderate number of projectors (e.g., 32 or 64 projectors), the cost of a multi-projector 3D display system may become prohibitive due to the cost and complexity of integrating multiple projectors. In this article, we describe an optical design technique for a class of multiview 3D display systems that use only a single projector. In this single projector multiview (SPM) system design, multiple views for the 3D display are generated in a time-multiplex fashion by the single high speed projector with specially designed optical components, a scanning mirror, and a reflective mirror array. Images of all views are generated sequentially and projected via the specially design optical system from different viewing directions towards a 3D display screen. Therefore, the single projector is able to generate equivalent number of multiview images from multiple viewing directions, thus fulfilling the tasks of multiple projectors. An obvious advantage of the proposed SPM technique is the significant reduction of cost, size, and complexity, especially when the number of views is high. The SPM strategy also alleviates the time-consuming procedures for multi-projector calibration. The design method is flexible and scalable and can accommodate systems with different number of views.

  13. Two Aircraft Head-Up Traffic Surveillance Symbology Issues: Range Filter and Inboard Field-of-View Symbology

    NASA Technical Reports Server (NTRS)

    Wong, Douglas T.; Kramer, Lynda J.; Norman, R. Michael

    2004-01-01

    The purpose of the eXternal Visibility System (XVS) effort for NASA s High-Speed Research Program was to determine and to provide required pilot visual information for a High Speed Civil Transport vehicle concept to allow safe and efficient operation in the absence of forward windows. The objective of this preliminary experiment conducted at NASA Langley Research Center was to investigate two head-up surveillance symbology (HUSS) display issues. The first issue was concerned with the benefits of adding a range filter to the current HUSS concept. A range filter limits the amount of traffic symbols displayed head-up by setting a range boundary (e.g. 7-nmi) around the ownship. The second issue was concerned with the need to incorporate HUSS in the inboard field-of-view (IFOV) display of the XVS concept. The hypothesis tested was that adding a range filter to the XVS display and HUSS to the IFOV display would enhance the pilot s effectiveness of traffic surveillance tasks. Using a high-resolution graphics flight simulator, each of three pilots flew departure and arrival scenarios under visual meteorological conditions. The pilots main tasks, while managing flight path, were to detect and assess potential airborne traffic hazards and to maintain overall situation awareness. Upon completing all the runs, each pilot completed a subjective questionnaire. Results showed that having both the HUSS on the IFOV and the range filter on each of the XVS displays enhanced the effectiveness of the XVS surveillance display concept. This configuration had the least head down time and the lowest mental workload. Combining both features gave the best target detection, the earliest threat recognition, and enabled the pilots to create a better strategy for evasive action when it became necessary.

  14. New Magnetic Microactuator Design Based on PDMS Elastomer and MEMS Technologies for Tactile Display.

    PubMed

    Streque, Jeremy; Talbi, Abdelkrim; Pernod, Philippe; Preobrazhensky, Vladimir

    2010-01-01

    Highly efficient tactile display devices must fulfill technical requirements for tactile stimulation, all the while preserving the lightness and compactness needed for handheld operation. This paper focuses on the elaboration of highly integrated magnetic microactuators for tactile display devices. FEM simulation, conception, fabrication, and characterization of these microactuators are presented in this paper. The current demonstrator offers a 4 × 4 flexible microactuator array with a resolution of 2 mm. Each actuator is composed of a Poly (Dimethyl-Siloxane) (PDMS) elastomeric membrane, magnetically actuated by coil-magnet interaction. It represents a proof of concept for fully integrated MEMS tactile devices, with fair actuation forces provided for a power consumption up to 100 mW per microactuator. The prototypes are destined to provide both static and dynamic tactile sensations, with an optimized membrane geometry for actuation frequencies between DC and 350 Hz. On the basis of preliminary experiments, this display device can offer skin stimulations for various tactile stimuli for applications in the fields of Virtual Reality or Human-Computer Interaction (HCI). Moreover, the elastomeric material used in this device and its global compactness offer great advantages in matter of comfort of use and capabilities of integration in haptic devices.

  15. Live small-animal X-ray lung velocimetry and lung micro-tomography at the Australian Synchrotron Imaging and Medical Beamline.

    PubMed

    Murrie, Rhiannon P; Morgan, Kaye S; Maksimenko, Anton; Fouras, Andreas; Paganin, David M; Hall, Chris; Siu, Karen K W; Parsons, David W; Donnelley, Martin

    2015-07-01

    The high flux and coherence produced at long synchrotron beamlines makes them well suited to performing phase-contrast X-ray imaging of the airways and lungs of live small animals. Here, findings of the first live-animal imaging on the Imaging and Medical Beamline (IMBL) at the Australian Synchrotron are reported, demonstrating the feasibility of performing dynamic lung motion measurement and high-resolution micro-tomography. Live anaesthetized mice were imaged using 30 keV monochromatic X-rays at a range of sample-to-detector propagation distances. A frame rate of 100 frames s(-1) allowed lung motion to be determined using X-ray velocimetry. A separate group of humanely killed mice and rats were imaged by computed tomography at high resolution. Images were reconstructed and rendered to demonstrate the capacity for detailed, user-directed display of relevant respiratory anatomy. The ability to perform X-ray velocimetry on live mice at the IMBL was successfully demonstrated. High-quality renderings of the head and lungs visualized both large structures and fine details of the nasal and respiratory anatomy. The effect of sample-to-detector propagation distance on contrast and resolution was also investigated, demonstrating that soft tissue contrast increases, and resolution decreases, with increasing propagation distance. This new capability to perform live-animal imaging and high-resolution micro-tomography at the IMBL enhances the capability for investigation of respiratory diseases and the acceleration of treatment development in Australia.

  16. Time multiplexing for increased FOV and resolution in virtual reality

    NASA Astrophysics Data System (ADS)

    Miñano, Juan C.; Benitez, Pablo; Grabovičkić, Dejan; Zamora, Pablo; Buljan, Marina; Narasimhan, Bharathwaj

    2017-06-01

    We introduce a time multiplexing strategy to increase the total pixel count of the virtual image seen in a VR headset. This translates into an improvement of the pixel density or the Field of View FOV (or both) A given virtual image is displayed by generating a succession of partial real images, each representing part of the virtual image and together representing the virtual image. Each partial real image uses the full set of physical pixels available in the display. The partial real images are successively formed and combine spatially and temporally to form a virtual image viewable from the eye position. Partial real images are imaged through different optical channels depending of its time slot. Shutters or other schemes are used to avoid that a partial real image be imaged through the wrong optical channels or at the wrong time slot. This time multiplexing strategy needs real images be shown at high frame rates (>120fps). Available display and shutters technologies are discussed. Several optical designs for achieving this time multiplexing scheme in a compact format are shown. This time multiplexing scheme allows increasing the resolution/FOV of the virtual image not only by increasing the physical pixel density but also by decreasing the pixels switching time, a feature that may be simpler to achieve in certain circumstances.

  17. Yeast cell surface display for lipase whole cell catalyst and its applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yun; Zhang, Rui; Lian, Zhongshuai

    The cell surface display technique allows for the expression of target proteins or peptides on the microbial cell surface by fusing an appropriate protein as an anchoring motif. Yeast display systems, such as Pichia pastoris, Yarowia lipolytica and Saccharomyces cerevisiae, are ideal, alternative and extensive display systems with the advantage of simple genetic manipulation and post-translational modification of expressed heterologous proteins. Engineered yeasts show high performance characteristics and variant utilizations. Herein, we comprehensively summarize the variant factors affecting lipase whole cell catalyst activity and display efficiency, including the structure and size of target proteins, screening anchor proteins, type and chainmore » length of linkers, and the appropriate matching rules among the above-mentioned display units. Furthermore, we also address novel approaches to enhance stability and activity of recombinant lipases, such as VHb gene co-expression, multi-enzyme co-display technique, and the micro-environmental interference and self-assembly techniques. Finally, we represent the variety of applications of whole cell surface displayed lipases on yeast cells in non-aqueous phases, including synthesis of esters, PUFA enrichment, resolution of chiral drugs, organic synthesis and biofuels. We demonstrate that the lipase surface display technique is a powerful tool for functionalizing yeasts to serve as whole cell catalysts, and increasing interest is providing an impetus for broad application of this technique.« less

  18. Use of Patterned CNT Arrays for Display Purposes

    NASA Technical Reports Server (NTRS)

    Delzeit, Lance D. (Inventor); Schipper, John F. (Inventor)

    2009-01-01

    Method and system for providing a dynamically reconfigurable display having nanometer-scale resolution, using a patterned array of multi-wall carbon nanotube (MWCNT) clusters. A diode, phosphor or other light source on each MWCNT cluster is independently activated, and different color light sources (e.g., red, green, blue, grey scale, infrared) can be mixed if desired. Resolution is estimated to be 40-100 nm, and reconfiguration time for each MWCNT cluster is no greater than one microsecond.

  19. Amorphous silicon thin film transistor active-matrix organic light-emitting diode displays fabricated on flexible substrates

    NASA Astrophysics Data System (ADS)

    Nichols, Jonathan A.

    Organic light-emitting diode (OLED) displays are of immense interest because they have several advantages over liquid crystal displays, the current dominant flat panel display technology. OLED displays are emissive and therefore are brighter, have a larger viewing angle, and do not require backlights and filters, allowing thinner, lighter, and more power efficient displays. The goal of this work was to advance the state-of-the-art in active-matrix OLED display technology. First, hydrogenated amorphous silicon (a-Si:H) thin film transistor (TFT) active-matrix OLED pixels and arrays were designed and fabricated on glass substrates. The devices operated at low voltages and demonstrated that lower performance TFTs could be utilized in active-matrix OLED displays, possibly allowing lower cost processing and the use of polymeric substrates. Attempts at designing more control into the display at the pixel level were also made. Bistable (one bit gray scale) active-matrix OLED pixels and arrays were designed and fabricated. Such pixels could be used in novel applications and eventually help reduce the bandwidth requirements in high-resolution and large-area displays. Finally, a-Si:H TFT active-matrix OLED pixels and arrays were fabricated on a polymeric substrate. Displays fabricated on a polymeric substrates would be lightweight; flexible, more rugged, and potentially less expensive to fabricate. Many of the difficulties associated with fabricating active-matrix backplanes on flexible substrates were studied and addressed.

  20. Development of high sensitivity and high speed large size blank inspection system LBIS

    NASA Astrophysics Data System (ADS)

    Ohara, Shinobu; Yoshida, Akinori; Hirai, Mitsuo; Kato, Takenori; Moriizumi, Koichi; Kusunose, Haruhiko

    2017-07-01

    The production of high-resolution flat panel displays (FPDs) for mobile phones today requires the use of high-quality large-size photomasks (LSPMs). Organic light emitting diode (OLED) displays use several transistors on each pixel for precise current control and, as such, the mask patterns for OLED displays are denser and finer than the patterns for the previous generation displays throughout the entire mask surface. It is therefore strongly demanded that mask patterns be produced with high fidelity and free of defect. To enable the production of a high quality LSPM in a short lead time, the manufacturers need a high-sensitivity high-speed mask blank inspection system that meets the requirement of advanced LSPMs. Lasertec has developed a large-size blank inspection system called LBIS, which achieves high sensitivity based on a laser-scattering technique. LBIS employs a high power laser as its inspection light source. LBIS's delivery optics, including a scanner and F-Theta scan lens, focus the light from the source linearly on the surface of the blank. Its specially-designed optics collect the light scattered by particles and defects generated during the manufacturing process, such as scratches, on the surface and guide it to photo multiplier tubes (PMTs) with high efficiency. Multiple PMTs are used on LBIS for the stable detection of scattered light, which may be distributed at various angles due to irregular shapes of defects. LBIS captures 0.3mμ PSL at a detection rate of over 99.5% with uniform sensitivity. Its inspection time is 20 minutes for a G8 blank and 35 minutes for G10. The differential interference contrast (DIC) microscope on the inspection head of LBIS captures high-contrast review images after inspection. The images are classified automatically.

  1. Acquisition of stereo panoramas for display in VR environments

    NASA Astrophysics Data System (ADS)

    Ainsworth, Richard A.; Sandin, Daniel J.; Schulze, Jurgen P.; Prudhomme, Andrew; DeFanti, Thomas A.; Srinivasan, Madhusudhanan

    2011-03-01

    Virtual reality systems are an excellent environment for stereo panorama displays. The acquisition and display methods described here combine high-resolution photography with surround vision and full stereo view in an immersive environment. This combination provides photographic stereo-panoramas for a variety of VR displays, including the StarCAVE, NexCAVE, and CORNEA. The zero parallax point used in conventional panorama photography is also the center of horizontal and vertical rotation when creating photographs for stereo panoramas. The two photographically created images are displayed on a cylinder or a sphere. The radius from the viewer to the image is set at approximately 20 feet, or at the object of major interest. A full stereo view is presented in all directions. The interocular distance, as seen from the viewer's perspective, displaces the two spherical images horizontally. This presents correct stereo separation in whatever direction the viewer is looking, even up and down. Objects at infinity will move with the viewer, contributing to an immersive experience. Stereo panoramas created with this acquisition and display technique can be applied without modification to a large array of VR devices having different screen arrangements and different VR libraries.

  2. Tomato bushy stunt virus (TBSV), a versatile platform for polyvalent display of antigenic epitopes and vaccine design.

    PubMed

    Kumar, Shantanu; Ochoa, Wendy; Singh, Pratik; Hsu, Catherine; Schneemann, Anette; Manchester, Marianne; Olson, Mark; Reddy, Vijay

    2009-05-25

    Viruses-like particles (VLPs) are frequently being used as platforms for polyvalent display of foreign epitopes of interest on their capsid surface to improve their presentation enhancing the antigenicity and host immune response. In the present study, we used the VLPs of Tomato bushy stunt virus (TBSV), an icosahedral plant virus, as a platform to display 180 copies of 16 amino acid epitopes of ricin toxin fused to the C-terminal end of a modified TBSV capsid protein (NDelta52). Expression of the chimeric recombinant protein in insect cells resulted in spontaneous assembly of VLPs displaying the ricin epitope. Cryo-electron microscopy and image reconstruction of the chimeric VLPs at 22 A resolution revealed the locations and orientation of the ricin epitope exposed on the TBSV capsid surface. Furthermore, injection of chimeric VLPs into mice generated antisera that detected the native ricin toxin. The ease of fusing of short peptides of 15-20 residues and their ability to form two kinds (T=1, T=3) of bio-nanoparticles that result in the display of 60 or 180 copies of less constrained and highly exposed antigenic epitopes makes TBSV an attractive and versatile display platform for vaccine design.

  3. Dissemination and Use of NPOESS Data in AWIPS II

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary; Burks, Jason

    2008-01-01

    Real-time satellite information provides one of many data sources used by NWS forecast offices to diagnose current weather conditions and to assist in short-term forecast preparation. While GOES satellite data provides relatively coarse spatial resolution coverage of the continental U.S. on a 10-15 minute repeat cycle, polar orbiting data has the potential to provide snapshots of weather conditions at high-resolution in many spectral channels. The multispectral polar orbiting satellite capabilities allow for the derivation of image and sounding products not available from geostationary orbit. The utility of these polar orbiting measurements to forecasters has been demonstrated with NASA EOS observations as part of the Short-term Prediction and Research Transition (SPORT) program at Marshall Space Flight Center. SPORT scientists have been providing real-time MODIS data to NWS forecasters on an experimental basis to address a variety of short-term weather forecasting problems since 2003. The launch of the NPOESS Preparatory Project (NPP) satellite in 2009 will extend the continuity of high-resolution data provided by the NASA EOS satellites into future operational weather systems. The NPP data will be available in a timeframe consistent with the early installation of the next generation Advanced Weather Information Processing System (AWIPS) under development by Raytheon for the NWS. The AWIPS II system will be a JAVA-based decision support system which preserves the functionality of the existing systems and offers unique development opportunities for new data sources and applications in the Service Orientated Architecture (SOA) environment. The poster will highlight some of the advanced observing and display- capabilities of these new systems such as plug-ins for NASA and NPP datasets, and the development of local applications which are not well handled in the current AWIPS (e.g., 3D displays of LMA data, generation and display of 3-channel color composites, etc.).

  4. Pilots strategically compensate for display enlargements in surveillance and flight control tasks.

    PubMed

    Stelzer, Emily Muthard; Wickens, Christopher D

    2006-01-01

    Experiments were conducted to assess the impact of display size on flight control, airspace surveillance, and goal-directed target search. Research of 3-D displays has shown that display scale compression influences the perception of flight path deviation, though less is known about the causes that drive this effect. In addition, research on attention-based tasks has shown that information displaced to significant eccentricities can amplify effort, but it is unclear whether the effect generates a performance difference in complex displays. In Experiment 1, 16 pilots completed a low-fidelity flight control task under single- and dual-axis control. In Experiment 2, the control task from Experiment 1 was scaled up to a more realistic flight environment, and pilots performed hazard surveillance and target search tasks. For flight control, pilots exhibited less path error and greater stick activity with a large display, which was attributed both to greater enhanced resolution and to the fact that larger depictions of error lead to greater urgency in correcting deviations. Size did not affect hazard surveillance or search, as pilots were adaptive in altering scanning patterns in response to the enlargement of the displays. Although pilots were adaptive to display changes in search and surveillance, display size reduction diminished estimates of flight path deviation and control performance because of lowered resolution and control urgency. Care should be taken when manipulating display size, as size reduction can diminish control performance.

  5. FSC LCD technology for military and avionics applications

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri R.; Schmidt, John; Roush, Jerry

    2009-05-01

    Field sequential color (FSC) liquid crystal displays (LCD) using a high speed LCD mode and an R, G, B LED backlight, offers a significant potential for lower power consumption, higher resolution, higher brightness and lower cost compared to the conventional R, G, B color filter based LCD, and thus is of interest to various military and avionic display applications. While the DLP projection TVs, and Camcorder LCD view finder type displays using the FSC technology have been introduced in the consumer market, large area direct view LCD displays based on the FSC technology have not reached the commercial market yet. Further, large area FSC LCDs can present unique operational issues in avionic and military environments particularly for operation in a broad temperature range and with respect to its susceptibility for the color breakup image artifact. In this paper we will review the current status of the FSC LCD technology and then discuss the results of our efforts on the FSC LCD technology evaluation for the avionic applications.

  6. Reading performance with large fonts on high-resolution displays

    NASA Astrophysics Data System (ADS)

    Powers, Maureen K.; Larimer, James O.; Gille, Jennifer; Liu, Hsien-Chang

    2004-06-01

    Reading is a fundamental task and skill in many environments including business, education, and the home. Today, reading often occurs on electronic displays in addition to traditional hard copy media such as books and magazines, presenting issues of legibility and other factors that can affect human performance [1]. In fact, the transition to soft copy media for text images is often met with worker complaints about their vision and comfort while reading [2-6]. Careful comparative evaluations of reading performance across hard and soft copy device types are rare, even though they are clearly important given the rapid and substantial improvements in soft copy devices available in the marketplace over the last 5 years. To begin to fill this evaluation gap, we compared reading performance on three different soft copy devices and traditional paper. This study does not investigate comfort factors such as display location, seating comfort, and more general issues of lighting, rather we focus instead on a narrow examination of reading performance differences across display types when font sizes are large.

  7. Light-field and holographic three-dimensional displays [Invited].

    PubMed

    Yamaguchi, Masahiro

    2016-12-01

    A perfect three-dimensional (3D) display that satisfies all depth cues in human vision is possible if a light field can be reproduced exactly as it appeared when it emerged from a real object. The light field can be generated based on either light ray or wavefront reconstruction, with the latter known as holography. This paper first provides an overview of the advances of ray-based and wavefront-based 3D display technologies, including integral photography and holography, and the integration of those technologies with digital information systems. Hardcopy displays have already been used in some applications, whereas the electronic display of a light field is under active investigation. Next, a fundamental question in this technology field is addressed: what is the difference between ray-based and wavefront-based methods for light-field 3D displays? In considering this question, it is of particular interest to look at the technology of holographic stereograms. The phase information in holography contributes to the resolution of a reconstructed image, especially for deep 3D images. Moreover, issues facing the electronic display system of light fields are discussed, including the resolution of the spatial light modulator, the computational techniques of holography, and the speckle in holographic images.

  8. Kuwait City, Kuwait as seen from STS-59

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The radiating transportation pattern of this 20th-Century urban plan is nicely displayed in this high-resolution photograph. Light-toned spots in the desrt mark oil well sites; along the south edge of the scene, some dark residue remains from the fires set during the recent Gulf War. Blown sand has nearly hidden the soot and thick oil that were deposited on the surface.

  9. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2002-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

  10. Stereoscopic Configurations To Minimize Distortions

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.

    1991-01-01

    Proposed television system provides two stereoscopic displays. Two-camera, two-monitor system used in various camera configurations and with stereoscopic images on monitors magnified to various degrees. Designed to satisfy observer's need to perceive spatial relationships accurately throughout workspace or to perceive them at high resolution in small region of workspace. Potential applications include industrial, medical, and entertainment imaging and monitoring and control of telemanipulators, telerobots, and remotely piloted vehicles.

  11. 3D Graphics For Interactive Surgical Simulation And Implant Design

    NASA Astrophysics Data System (ADS)

    Dev, P.; Fellingham, L. L.; Vassiliadis, A.; Woolson, S. T.; White, D. N.; Young, S. L.

    1984-10-01

    The combination of user-friendly, highly interactive software, 3D graphics, and the high-resolution detailed views of anatomy afforded by X-ray computer tomography and magnetic resonance imaging can provide surgeons with the ability to plan and practice complex surgeries. In addition to providing a realistic and manipulable 3D graphics display, this system can drive a milling machine in order to produce physical models of the anatomy or prosthetic devices and implants which have been designed using its interactive graphics editing facilities.

  12. High Resolution Radioluminescence Microscopy for the Study of Prostate Tissue Slice Cell Metabolism and Monitoring of Treatment Response

    DTIC Science & Technology

    2016-12-01

    REPORT DATE : December 2016 TYPE OF REPORT: Final PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) December 2016 2. REPORT...TYPE Final 3. DATES COVERED (From - To) 30Sept2014 - 29Sept2016 4. TITLE AND SUBTITLE Monitoring of Treatment Response 5a. CONTRACT NUMBER High

  13. Relativistic astrophysics. [design analysis and performance tests of Cerenkov counters for detection of iron isotopes

    NASA Technical Reports Server (NTRS)

    Price, P. B.

    1976-01-01

    The design, experimental testing, and calibration (error analysis) of a high resolution Cerenkov-scintillation detector is presented. The detector is capable of detecting iron isotopes and heavy ions of cosmic rays, and of performing direct measurements of individual neighboring isotopes at charge resolution 26. It utilizes Lexan (trademark) sheets, and has been used in flight packages of balloons and on the Skylab. The detector will be able to provide more information on violet astrophysical processes, such as thermonuclear reactions on neutron stars. Ground support and display equipment which are to be used in conjunction with the detector are also discussed.

  14. Fast Low-Cost Multiple Sensor Readout System

    DOEpatents

    Carter-Lewis, David; Krennich, Frank; Le Bohec, Stephane; Petry, Dirk; Sleege, Gary

    2004-04-06

    A low resolution data acquisition system is presented. The data acquisition system has a plurality of readout modules serially connected to a controller. Each readout module has a FPGA in communication with analog to digital (A/D) converters, which are connected to sensors. The A/D converter has eight bit or lower resolution. The FPGA detects when a command is addressed to it and commands the A/D converters to convert analog sensor data into digital data. The digital data is sent on a high speed serial communication bus to the controller. A graphical display is used in one embodiment to indicate if a sensor reading is outside of a predetermined range.

  15. Exploring the impacts of physics and resolution on aqua-planet simulations from a nonhydrostatic global variable-resolution modeling framework: IMPACTS OF PHYSICS AND RESOLUTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Chun; Leung, L. Ruby; Park, Sang-Hun

    Advances in computing resources are gradually moving regional and global numerical forecasting simulations towards sub-10 km resolution, but global high resolution climate simulations remain a challenge. The non-hydrostatic Model for Prediction Across Scales (MPAS) provides a global framework to achieve very high resolution using regional mesh refinement. Previous studies using the hydrostatic version of MPAS (H-MPAS) with the physics parameterizations of Community Atmosphere Model version 4 (CAM4) found notable resolution dependent behaviors. This study revisits the resolution sensitivity using the non-hydrostatic version of MPAS (NH-MPAS) with both CAM4 and CAM5 physics. A series of aqua-planet simulations at global quasi-uniform resolutionsmore » ranging from 240 km to 30 km and global variable resolution simulations with a regional mesh refinement of 30 km resolution over the tropics are analyzed, with a primary focus on the distinct characteristics of NH-MPAS in simulating precipitation, clouds, and large-scale circulation features compared to H-MPAS-CAM4. The resolution sensitivity of total precipitation and column integrated moisture in NH-MPAS is smaller than that in H-MPAS-CAM4. This contributes importantly to the reduced resolution sensitivity of large-scale circulation features such as the inter-tropical convergence zone and Hadley circulation in NH-MPAS compared to H-MPAS. In addition, NH-MPAS shows almost no resolution sensitivity in the simulated westerly jet, in contrast to the obvious poleward shift in H-MPAS with increasing resolution, which is partly explained by differences in the hyperdiffusion coefficients used in the two models that influence wave activity. With the reduced resolution sensitivity, simulations in the refined region of the NH-MPAS global variable resolution configuration exhibit zonally symmetric features that are more comparable to the quasi-uniform high-resolution simulations than those from H-MPAS that displays zonal asymmetry in simulations inside the refined region. Overall, NH-MPAS with CAM5 physics shows less resolution sensitivity compared to CAM4. These results provide a reference for future studies to further explore the use of NH-MPAS for high-resolution climate simulations in idealized and realistic configurations.« less

  16. A passive cooling system proposal for multifunction and high-power displays

    NASA Astrophysics Data System (ADS)

    Tari, Ilker

    2013-03-01

    Flat panel displays are conventionally cooled by internal natural convection, which constrains the possible rate of heat transfer from the panel. On one hand, during the last few years, the power consumption and the related cooling requirement for 1080p displays have decreased mostly due to energy savings by the switch to LED backlighting and more efficient electronics. However, on the other hand, the required cooling rate recently started to increase with new directions in the industry such as 3D displays, and ultra-high-resolution displays (recent 4K announcements and planned introduction of 8K). In addition to these trends in display technology itself, there is also a trend to integrate consumer entertainment products into displays with the ultimate goal of designing a multifunction device replacing the TV, the media player, the PC, the game console and the sound system. Considering the increasing power requirement for higher fidelity in video processing, these multifunction devices tend to generate very high heat fluxes, which are impossible to dissipate with internal natural convection. In order to overcome this obstacle, instead of active cooling with forced convection that comes with drawbacks of noise, additional power consumption, and reduced reliability, a passive cooling system relying on external natural convection and radiation is proposed here. The proposed cooling system consists of a heat spreader flat heat pipe and aluminum plate-finned heat sink with anodized surfaces. For this system, the possible maximum heat dissipation rates from the standard size panels (in 26-70 inch range) are estimated by using our recently obtained heat transfer correlations for the natural convection from aluminum plate-finned heat sinks together with the surface-to-surface radiation. With the use of the proposed passive cooling system, the possibility of dissipating very high heat rates is demonstrated, hinting a promising green alternative to active cooling.

  17. A theoretical and experimental benchmark study of core-excited states in nitrogen

    NASA Astrophysics Data System (ADS)

    Myhre, Rolf H.; Wolf, Thomas J. A.; Cheng, Lan; Nandi, Saikat; Coriani, Sonia; Gühr, Markus; Koch, Henrik

    2018-02-01

    The high resolution near edge X-ray absorption fine structure spectrum of nitrogen displays the vibrational structure of the core-excited states. This makes nitrogen well suited for assessing the accuracy of different electronic structure methods for core excitations. We report high resolution experimental measurements performed at the SOLEIL synchrotron facility. These are compared with theoretical spectra calculated using coupled cluster theory and algebraic diagrammatic construction theory. The coupled cluster singles and doubles with perturbative triples model known as CC3 is shown to accurately reproduce the experimental excitation energies as well as the spacing of the vibrational transitions. The computational results are also shown to be systematically improved within the coupled cluster hierarchy, with the coupled cluster singles, doubles, triples, and quadruples method faithfully reproducing the experimental vibrational structure.

  18. Display device-adapted video quality-of-experience assessment

    NASA Astrophysics Data System (ADS)

    Rehman, Abdul; Zeng, Kai; Wang, Zhou

    2015-03-01

    Today's viewers consume video content from a variety of connected devices, including smart phones, tablets, notebooks, TVs, and PCs. This imposes significant challenges for managing video traffic efficiently to ensure an acceptable quality-of-experience (QoE) for the end users as the perceptual quality of video content strongly depends on the properties of the display device and the viewing conditions. State-of-the-art full-reference objective video quality assessment algorithms do not take into account the combined impact of display device properties, viewing conditions, and video resolution while performing video quality assessment. We performed a subjective study in order to understand the impact of aforementioned factors on perceptual video QoE. We also propose a full reference video QoE measure, named SSIMplus, that provides real-time prediction of the perceptual quality of a video based on human visual system behaviors, video content characteristics (such as spatial and temporal complexity, and video resolution), display device properties (such as screen size, resolution, and brightness), and viewing conditions (such as viewing distance and angle). Experimental results have shown that the proposed algorithm outperforms state-of-the-art video quality measures in terms of accuracy and speed.

  19. Novel Strategy to Evaluate Infectious Salmon Anemia Virus Variants by High Resolution Melting

    PubMed Central

    Sepúlveda, Dagoberto; Cárdenas, Constanza; Carmona, Marisela; Marshall, Sergio H.

    2012-01-01

    Genetic variability is a key problem in the prevention and therapy of RNA-based virus infections. Infectious Salmon Anemia virus (ISAv) is an RNA virus which aggressively attacks salmon producing farms worldwide and in particular in Chile. Just as with most of the Orthomyxovirus, ISAv displays high variability in its genome which is reflected by a wider infection potential, thus hampering management and prevention of the disease. Although a number of widely validated detection procedures exist, in this case there is a need of a more complex approach to the characterization of virus variability. We have adapted a procedure of High Resolution Melting (HRM) as a fine-tuning technique to fully differentiate viral variants detected in Chile and projected to other infective variants reported elsewhere. Out of the eight viral coding segments, the technique was adapted using natural Chilean variants for two of them, namely segments 5 and 6, recognized as virulence-associated factors. Our work demonstrates the versatility of the technique as well as its superior resolution capacity compared with standard techniques currently in use as key diagnostic tools. PMID:22719837

  20. Geomorphological Mapping of Sputnik Planum and Surrounding Terrain on Pluto

    NASA Astrophysics Data System (ADS)

    White, O. L.; Stern, S. A.; Weaver, H. A., Jr.; Olkin, C.; Ennico Smith, K.; Young, L. A.; Moore, J. M.; Cheng, A. F.

    2015-12-01

    The New Horizons flyby of Pluto in July 2015 has provided the first few close-up images of the Kuiper belt object, which reveal it to have a highly diverse range of terrains, implying a complex geological history. The highest resolution images that have yet been returned are seven lossy 400 m/pixel frames that cover the majority of the prominent Plutonian feature informally named Sputnik Planum (all feature names are currently informal), and its surroundings. This resolution is sufficient to allow detailed geomorphological mapping of this area to commence. Lossless versions of all 15 frames that make up the mosaic will be returned in September 2015, and the map presented at AGU will incorporate the total area covered by these frames. Sputnik Planum, with an area of ~650,000 km2, is notable for its smooth appearance and apparent total lack of impact craters at 400 m/pixel resolution. The Planum actually displays a wide variety of textures across its expanse, which includes smooth and pitted plains to the south, polygonal terrain at its center (the polygons can reach tens of kilometers in size and are bounded by troughs that sometimes feature central ridges), and, to the north, darker polygonal terrain displaying patterns indicative of glacial flow. Within these plains there exist several well-defined outcrops of a mottled, light/dark unit that reach from several to tens of kilometers across. Separating Sputnik Planum from the dark, cratered equatorial terrain of Cthulhu Regio on its south-western margin is a unit of chaotically arranged mountains; similar mountainous units exist on the south and western margins. The northern margin is bounded by rugged, hilly, cratered terrain into which ice of Sputnik Planum appears to be intruding in places. Terrain of similar relief exists to the east, but is much brighter than that to the north. The southernmost extent of the mosaic features a unit of rough, undulating terrain that displays very few impact craters at 400 m/pixel resolution.

  1. Digitally enhanced GLORIA images for petroleum exploration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prindle, R.O.; Lanz, K

    1990-05-01

    This poster presentation graphically depicts the geological and structural information that can be derived from digitally enhanced Geological Long Range Inclined Asdic (GLORIA) sonar images. This presentation illustrates the advantages of scale enlargement as an interpreter's tool in an offshore area within the Eel River Basin, Northern California. Sonographs were produced from digital tapes originally collected for the exclusive economic zone (EEZ)-SCAN 1984 survey, which was published in the Atlas of the Western Conterminous US at a scale of 1:500,000. This scale is suitable for displaying regional offshore tectonic features but does not have the resolution required for detailed geologicalmore » mapping necessary for petroleum exploration. Applications of digital enhancing techniques which utilize contrast stretching and assign false colors to wide-swath sonar imagery (approximately 40 km) with 50-m resolution enables the acquisition and interpretation of significantly more geological and structural data. This, combined with a scale enlargement to 1:100,000 and high contrast contact prints vs. the offset prints of the atlas, increases the resolution and sharpness of bathymetric features so that many more subtle features may be mapped in detail. A tectonic interpretation of these digitally enhanced GLORIA sonographs from the Eel River basin is presented, displaying anticlines, lineaments, ridge axis, pathways of sediment flow, and subtle doming. Many of these features are not present on published bathymetric maps and have not been derived from seismic data because the plan view spatial resolution is much less than that available from the GLORIA imagery.« less

  2. Architectural transitions in Vibrio cholerae biofilms at single-cell resolution

    PubMed Central

    Drescher, Knut; Dunkel, Jörn; Nadell, Carey D.; van Teeffelen, Sven; Grnja, Ivan; Wingreen, Ned S.; Stone, Howard A.; Bassler, Bonnie L.

    2016-01-01

    Many bacterial species colonize surfaces and form dense 3D structures, known as biofilms, which are highly tolerant to antibiotics and constitute one of the major forms of bacterial biomass on Earth. Bacterial biofilms display remarkable changes during their development from initial attachment to maturity, yet the cellular architecture that gives rise to collective biofilm morphology during growth is largely unknown. Here, we use high-resolution optical microscopy to image all individual cells in Vibrio cholerae biofilms at different stages of development, including colonies that range in size from 2 to 4,500 cells. From these data, we extracted the precise 3D cellular arrangements, cell shapes, sizes, and global morphological features during biofilm growth on submerged glass substrates under flow. We discovered several critical transitions of the internal and external biofilm architectures that separate the major phases of V. cholerae biofilm growth. Optical imaging of biofilms with single-cell resolution provides a new window into biofilm formation that will prove invaluable to understanding the mechanics underlying biofilm development. PMID:26933214

  3. World-Wide Web Tools for Locating Planetary Images

    NASA Technical Reports Server (NTRS)

    Kanefsky, Bob; Deiss, Ron (Technical Monitor)

    1995-01-01

    The explosive growth of the World-Wide Web (WWW) in the past year has made it feasible to provide interactive graphical tools to assist scientists in locating planetary images. The highest available resolution images of any site of interest can be quickly found on a map or plot, and, if online, displayed immediately on nearly any computer equipped with a color screen, an Internet connection, and any of the free WWW browsers. The same tools may also be of interest to educators, students, and the general public. Image finding tools have been implemented covering most of the solar system: Earth, Mars, and the moons and planets imaged by Voyager. The Mars image-finder, which plots the footprints of all the high-resolution Viking Orbiter images and can be used to display any that are available online, also contains a complete scrollable atlas and hypertext gazetteer to help locating areas. The Earth image-finder is linked to thousands of Shuttle images stored at NASA/JSC, and displays them as red dots on a globe. The Voyager image-finder plots images as dots, by longitude and apparent target size, linked to online images. The locator (URL) for the top-level page is http: //ic-www.arc.nasa.gov/ic/projects/bayes-group/Atlas/. Through the efforts of the Planetary Data System and other organizations, hundreds of thousands of planetary images are now available on CD-ROM, and many of these have been made available on the WWW. However, locating images of a desired site is still problematic, in practice. For example, many scientists studying Mars use digital image maps, which are one third the resolution of Viking Orbiter survey images. When they douse Viking Orbiter images, they often work with photographically printed hardcopies, which lack the flexibility of digital images: magnification, contrast stretching, and other basic image-processing techniques offered by off-the-shelf software. From the perspective of someone working on an experimental image processing technique for super-resolution, the discovery that potential users are often not using the highest resolution already available, nor using conventional image processing techniques, was surprising. This motivated the present work.

  4. Demonstration of high current carbon nanotube enabled vertical organic field effect transistors at industrially relevant voltages

    NASA Astrophysics Data System (ADS)

    McCarthy, Mitchell

    The display market is presently dominated by the active matrix liquid crystal display (LCD). However, the active matrix organic light emitting diode (AMOLED) display is argued to become the successor to the LCD, and is already beginning its way into the market, mainly in small size displays. But, for AMOLED technology to become comparable in market share to LCD, larger size displays must become available at a competitive price with their LCD counterparts. A major issue preventing low-cost large AMOLED displays is the thin-film transistor (TFT) technology. Unlike the voltage driven LCD, the OLEDs in the AMOLED display are current driven. Because of this, the mature amorphous silicon TFT backplane technology used in the LCD must be upgraded to a material possessing a higher mobility. Polycrystalline silicon and transparent oxide TFT technologies are being considered to fill this need. But these technologies bring with them significant manufacturing complexity and cost concerns. Carbon nanotube enabled vertical organic field effect transistors (CN-VFETs) offer a unique solution to this problem (now known as the AMOLED backplane problem). The CN-VFET allows the use of organic semiconductors to be used for the semiconductor layer. Organics are known for their low-cost large area processing compatibility. Although the mobility of the best organics is only comparable to that of amorphous silicon, the CN-VFET makes up for this by orienting the channel vertically, as opposed to horizontally (like in conventional TFTs). This allows the CN-VFET to achieve sub-micron channel lengths without expensive high resolution patterning. Additionally, because the CN-VFET can be easily converted into a light emitting transistor (called the carbon nanotube enabled vertical organic light emitting transistor---CN-VOLET) by essentially stacking an OLED on top of the CN-VFET, more potential benefits can be realized. These potential benefits include, increased aperture ratio, increased OLED lifetime and the potential for an all transparent display. And because carbon nanotubes (CNTs) and organics are used, CN-VFET and CN-VOLET devices are compatible with flexible displays. This dissertation describes the first ever demonstration of CN-VFETs and CN-VOLETs and relates their performance to the specific properties of the CNTs and the new device architecture. In the work that followed, the CN-VFET was systematically optimized overcoming the problems revealed in the demonstration devices. The large undesired hysteresis was decreased by 96%, the on/off ratio was improved three orders of magnitude and the operating voltages were reduced to state of the art values. Additionally, the current output per device area of the CN-VFET was demonstrated to be greater than any other low resolution patterned organic transistor by a factor of 3.9. Moreover, it was demonstrated that the CNTs induce a reorientation of the high mobility plane in small molecule organics like pentacene to coincide with the vertical direction, giving additional explanation for the large currents observed in the CN-VFET. The ability to drive high currents and potentially inexpensive fabrication may provide the solution for the AMOLED backplane problem.

  5. Modeling of digital information optical encryption system with spatially incoherent illumination

    NASA Astrophysics Data System (ADS)

    Bondareva, Alyona P.; Cheremkhin, Pavel A.; Krasnov, Vitaly V.; Rodin, Vladislav G.; Starikov, Rostislav S.; Starikov, Sergey N.

    2015-10-01

    State of the art micromirror DMD spatial light modulators (SLM) offer unprecedented framerate up to 30000 frames per second. This, in conjunction with high speed digital camera, should allow to build high speed optical encryption system. Results of modeling of digital information optical encryption system with spatially incoherent illumination are presented. Input information is displayed with first SLM, encryption element - with second SLM. Factors taken into account are: resolution of SLMs and camera, holograms reconstruction noise, camera noise and signal sampling. Results of numerical simulation demonstrate high speed (several gigabytes per second), low bit error rate and high crypto-strength.

  6. Black-on-white polymer-stabilized cholesteric formulations

    NASA Astrophysics Data System (ADS)

    West, John L.; Magyar, Gregory R.; Francl, James J.; Nixon, Christine M.

    1995-08-01

    Recent research by Doane, Yang, and Chien demonstrated the use of cholesteric liquid crystals in multiplexed, high resolution, reflective diplays. These materials utilize the bistability of the cholesteric planar and focal conic states for displays with a colored image on a black background. Many commercial applications of these materials, such as electronic books and newspapers, portable faxes and personal data assistants, require, or at least prefer, black-on- white images. We report on relatively high polymer content (equalsV 20% by weight) dispersions of cholesteric liquid crystals that produce a white, reflecting, planar state. The polymer network appears to form cholesteric domains with varying pitch lengths resulting in planar states that reflect in the red, green, and blue portions of the spectrum. Utilizing a black absorbing layer behind a display using these materials offers white images on a black background, or vice-versa.

  7. An atlas of monthly mean distributions of GEOSAT sea surface height, SSMI surface wind speed, AVHRR/2 sea surface temperature, and ECMWF surface wind components during 1988

    NASA Technical Reports Server (NTRS)

    Halpern, D.; Zlotnicki, V.; Newman, J.; Brown, O.; Wentz, F.

    1991-01-01

    Monthly mean global distributions for 1988 are presented with a common color scale and geographical map. Distributions are included for sea surface height variation estimated from GEOSAT; surface wind speed estimated from the Special Sensor Microwave Imager on the Defense Meteorological Satellite Program spacecraft; sea surface temperature estimated from the Advanced Very High Resolution Radiometer on NOAA spacecrafts; and the Cartesian components of the 10m height wind vector computed by the European Center for Medium Range Weather Forecasting. Charts of monthly mean value, sampling distribution, and standard deviation value are displayed. Annual mean distributions are displayed.

  8. Precise delay measurement through combinatorial logic

    NASA Technical Reports Server (NTRS)

    Burke, Gary R. (Inventor); Chen, Yuan (Inventor); Sheldon, Douglas J. (Inventor)

    2010-01-01

    A high resolution circuit and method for facilitating precise measurement of on-chip delays for FPGAs for reliability studies. The circuit embeds a pulse generator on an FPGA chip having one or more groups of LUTS (the "LUT delay chain"), also on-chip. The circuit also embeds a pulse width measurement circuit on-chip, and measures the duration of the generated pulse through the delay chain. The pulse width of the output pulse represents the delay through the delay chain without any I/O delay. The pulse width measurement circuit uses an additional asynchronous clock autonomous from the main clock and the FPGA propagation delay can be displayed on a hex display continuously for testing purposes.

  9. Nanoparticle Selective Laser Processing for a Flexible Display Fabrication

    NASA Astrophysics Data System (ADS)

    Seung Hwan Ko,; Heng Pan,; Daeho Lee,; Costas P. Grigoropoulos,; Hee K. Park,

    2010-05-01

    To demonstrate a first step for a novel fabrication method of a flexible display, nanomaterial based laser processing schemes to demonstrate organic light emitting diode (OLED) pixel transfer and organic field effect transistor (OFET) fabrication on a polymer substrate without using any conventional vacuum or photolithography processes were developed. The unique properties of nanomaterials allow laser induced forward transfer of organic light emitting material at low laser energy while maintaining good fluorescence and also allow high resolution transistor electrode patterning at plastic compatible low temperature. These novel processes enable an environmentally friendly and cost effective process as well as a low temperature manufacturing sequence to realize inexpensive, large area, flexible electronics on polymer substrates.

  10. 7 Tesla compatible in-bore display for functional magnetic resonance imaging.

    PubMed

    Groebner, Jens; Berger, Moritz Cornelius; Umathum, Reiner; Bock, Michael; Rauschenberg, Jaane

    2013-08-01

    A liquid crystal display was modified for use inside a 7 T MR magnet. SNR measurements were performed using different imaging sequences with the monitor absent, present, or activated. fMRI with a volunteer was conducted using a visual stimulus. SNR was reduced by 3.7%/7.9% in echo planar/fast-spin echo images when the monitor was on which can be explained by the limited shielding of the coated front window (40 dB). In the fMRI experiments, activated regions in the visual cortex were clearly visible. The monitor provided excellent resolution at minor SNR reduction in EPI images, and is thus suitable for fMRI at ultra-high field.

  11. Pixel structures to compensate nonuniform threshold voltage and mobility of polycrystalline silicon thin-film transistors using subthreshold current for large-size active matrix organic light-emitting diode displays

    NASA Astrophysics Data System (ADS)

    Na, Jun-Seok; Kwon, Oh-Kyong

    2014-01-01

    We propose pixel structures for large-size and high-resolution active matrix organic light-emitting diode (AMOLED) displays using a polycrystalline silicon (poly-Si) thin-film transistor (TFT) backplane. The proposed pixel structures compensate the variations of the threshold voltage and mobility of the driving TFT using the subthreshold current. The simulated results show that the emission current error of the proposed pixel structure B ranges from -2.25 to 2.02 least significant bit (LSB) when the variations of the threshold voltage and mobility of the driving TFT are ±0.5 V and ±10%, respectively.

  12. [Modification and luminescence properties of transparent Lu2SiO5 : Ce3+ thin-film phosphors].

    PubMed

    Fan, Yang-Yang; Liu, Xiao-Lin; Gu, Mu; Ni, Chen; Huang, Shi-Ming; Liu, Bo

    2011-02-01

    To achieve high-spatial-resolution for X-ray imaging and flat panel display, transparent thin-film phosphors have been attracted much attention in recent years. In comparison with conventional powder phosphors, the transparent thin-film phosphors have some outstanding advantages such as high contrast and resolution, superior thermal conductivity and better adhesion. Cerium-doped lutetium oxyorthosilicate Lu2 SiO5 (LSO) is one promising candidate due to its high density (7.4 g x cm(-3)), high light yield (27 300 photons x MeV(-1)), short decay time (40 ns), and excellent chemical stability. The sol-gel method is one of the most important techniques for deposition of functional thin films, because it possesses a number of advantages over conventional film formation techniques, such as low processing temperature, easy coating of large surfaces, homogenous multicomponent films, and cheap equipments. In X-ray imaging application, the thickness of the thin-film phosphor is the most important factor, which can increase X-ray absorption of the film and then strengthen its luminescence intensity. In the present work, transparent LSO : Ce film was successfully prepared using sol-gel method and spin-coating technique by using inorganic salts as raw materials, 2-methoxyethanol as solvent, and poly (ethylene glycol) (PEG) as modifier without inert atmosphere. The effect of PEG on the luminescence properties of the film was investigated in detail. The results indicated that PEG200 played an important role in the formation of LSO : Ce film, improving its quality and luminescent intensity. The film thickness of 0.9 microm was achieved after 5 times of coating. The luminescence properties of the film were studied. Their performances were good, which implied that the film would have promising applications in high-spatial-resolution X-ray imaging and flat panel display devices.

  13. Chemically amplified i-line positive resist for next-generation flat panel display

    NASA Astrophysics Data System (ADS)

    Lee, Hsing-Chieh; Lu, Ying-Hao; Huang, Shin-Yih; Lan, Wei-Jen; Hanabata, Makoto

    2017-03-01

    Traditional diazonaphthoquinone (DNQ) positive photoresists are widely used for TFT-LCD array process. Current LTPS technology has more than 600ppi resolution is required for small or middle-sized TFT liquid crystal display panels. One of the ways to enhance resolution is to apply i-line single exposure system instead of traditional g/h/ibroadband exposure system. We have been developing i-line chemically amplified photoresist ECA 200 series for the next generation flat panel display (FPD). ECA 200 consists of three components: a phenol resin, a photo acid generator and dissolution enhancer. We applied two different types of dissolution enhancers with two different kinds of protected groups to our resist materials. As a result, we achieved higher sensitivity, higher resolution, less footing of the resist profile and reduced standing wave effect compared with traditional DNQ photoresists. In addition, we have found further property of photoresist that does not need post exposure bake (PEB) process. This resist has a great advantage at most of current panel plants without PEB process.

  14. Review of ultraresolution (10-100 megapixel) visualization systems built by tiling commercial display components

    NASA Astrophysics Data System (ADS)

    Hopper, Darrel G.; Haralson, David G.; Simpson, Matthew A.; Longo, Sam J.

    2002-08-01

    Ultra-resolution visualization systems are achieved by the technique of tiling many direct or project-view displays. During the past fews years, several such systems have been built from commercial electronics components (displays, computers, image generators, networks, communication links, and software). Civil applications driving this development have independently determined that they require images at 10-100 megapixel (Mpx) resolution to enable state-of-the-art research, engineering, design, stock exchanges, flight simulators, business information and enterprise control centers, education, art and entertainment. Military applications also press the art of the possible to improve the productivity of warfighters and lower the cost of providing for the national defense. The environment in some 80% of defense applications can be addressed by ruggedization of commercial components. This paper reviews the status of ultra-resolution systems based on commercial components and describes a vision for their integration into advanced yet affordable military command centers, simulator/trainers, and, eventually, crew stations in air, land, sea and space systems.

  15. High-resolution three-dimensional imaging radar

    NASA Technical Reports Server (NTRS)

    Cooper, Ken B. (Inventor); Chattopadhyay, Goutam (Inventor); Siegel, Peter H. (Inventor); Dengler, Robert J. (Inventor); Schlecht, Erich T. (Inventor); Mehdi, Imran (Inventor); Skalare, Anders J. (Inventor)

    2010-01-01

    A three-dimensional imaging radar operating at high frequency e.g., 670 GHz, is disclosed. The active target illumination inherent in radar solves the problem of low signal power and narrow-band detection by using submillimeter heterodyne mixer receivers. A submillimeter imaging radar may use low phase-noise synthesizers and a fast chirper to generate a frequency-modulated continuous-wave (FMCW) waveform. Three-dimensional images are generated through range information derived for each pixel scanned over a target. A peak finding algorithm may be used in processing for each pixel to differentiate material layers of the target. Improved focusing is achieved through a compensation signal sampled from a point source calibration target and applied to received signals from active targets prior to FFT-based range compression to extract and display high-resolution target images. Such an imaging radar has particular application in detecting concealed weapons or contraband.

  16. Copernicus observations of Ly-alpha and Mg II emission from HR 1099 /V711 Tauri/ and UX Ari

    NASA Technical Reports Server (NTRS)

    Weiler, E. J.

    1978-01-01

    Ultraviolet observations of two RS CVn binaries obtained with Copernicus are described. High-resolution (0.05 A) U1 observations indicate that both HR 1099 and UX Ari display broad Ly-alpha emission. The Ly-alpha emission strength from HR 1099 is variable and seems to be correlated with orbital phase, while the UX Ari results indicate no significant variation. Moderate resolution (0.51 A) V2 scans of both systems show variable Mg II h and k emission-line profiles which usually matched the velocity of the more active star in each binary. Additionally, displaced emission components were seen at velocities of up to + or - 250 km/s, indicative of high-velocity gas motions. The radial velocities of these emission features from HR 1099 are marginally correlated with orbital phase. Highly active and variable chromospheric phenomena are found to be the most consistent explanation of these results.

  17. Knowledge representation in space flight operations

    NASA Technical Reports Server (NTRS)

    Busse, Carl

    1989-01-01

    In space flight operations rapid understanding of the state of the space vehicle is essential. Representation of knowledge depicting space vehicle status in a dynamic environment presents a difficult challenge. The NASA Jet Propulsion Laboratory has pursued areas of technology associated with the advancement of spacecraft operations environment. This has led to the development of several advanced mission systems which incorporate enhanced graphics capabilities. These systems include: (1) Spacecraft Health Automated Reasoning Prototype (SHARP); (2) Spacecraft Monitoring Environment (SME); (3) Electrical Power Data Monitor (EPDM); (4) Generic Payload Operations Control Center (GPOCC); and (5) Telemetry System Monitor Prototype (TSM). Knowledge representation in these systems provides a direct representation of the intrinsic images associated with the instrument and satellite telemetry and telecommunications systems. The man-machine interface includes easily interpreted contextual graphic displays. These interactive video displays contain multiple display screens with pop-up windows and intelligent, high resolution graphics linked through context and mouse-sensitive icons and text.

  18. Perspective: Toward efficient GaN-based red light emitting diodes using europium doping

    NASA Astrophysics Data System (ADS)

    Mitchell, Brandon; Dierolf, Volkmar; Gregorkiewicz, Tom; Fujiwara, Yasufumi

    2018-04-01

    While InGaN/GaN blue and green light-emitting diodes (LEDs) are commercially available, the search for an efficient red LED based on GaN is ongoing. The realization of this LED is crucial for the monolithic integration of the three primary colors and the development of nitride-based full-color high-resolution displays. In this perspective, we will address the challenges of attaining red luminescence from GaN under current injection and the methods that have been developed to circumvent them. While several approaches will be mentioned, a large emphasis will be placed on the recent developments of doping GaN with Eu3+ to achieve an efficient red GaN-based LED. Finally, we will provide an outlook to the future of this material as a candidate for small scale displays such as mobile device screens or micro-LED displays.

  19. Mass data graphics requirements for symbol generators: example 2D airport navagation and 3D terrain function

    NASA Astrophysics Data System (ADS)

    Schiefele, Jens; Bader, Joachim; Kastner, S.; Wiesemann, Thorsten; von Viebahn, Harro

    2002-07-01

    Next generation of cockpit display systems will display mass data. Mass data includes terrain, obstacle, and airport databases. Display formats will be two and eventually 3D. A prerequisite for the introduction of these new functions is the availability of certified graphics hardware. The paper describes functionality and required features of an aviation certified 2D/3D graphics board. This graphics board should be based on low-level and hi-level API calls. These graphic calls should be very similar to OpenGL. All software and the API must be aviation certified. As an example application, a 2D airport navigation function and a 3D terrain visualization is presented. The airport navigation format is based on highly precise airport database following EUROCAE ED-99/RTCA DO-272 specifications. Terrain resolution is based on EUROCAE ED-98/RTCA DO-276 requirements.

  20. Visualization of the Eastern Renewable Generation Integration Study: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gruchalla, Kenny; Novacheck, Joshua; Bloom, Aaron

    The Eastern Renewable Generation Integration Study (ERGIS), explores the operational impacts of the wide spread adoption of wind and solar photovoltaics (PV) resources in the U.S. Eastern Interconnection and Quebec Interconnection (collectively, EI). In order to understand some of the economic and reliability challenges of managing hundreds of gigawatts of wind and PV generation, we developed state of the art tools, data, and models for simulating power system operations using hourly unit commitment and 5-minute economic dispatch over an entire year. Using NREL's high-performance computing capabilities and new methodologies to model operations, we found that the EI, as simulated withmore » evolutionary change in 2026, could balance the variability and uncertainty of wind and PV at a 5-minute level under a variety of conditions. A large-scale display and a combination of multiple coordinated views and small multiples were used to visually analyze the four large highly multivariate scenarios with high spatial and temporal resolutions. state of the art tools, data, and models for simulating power system operations using hourly unit commitment and 5-minute economic dispatch over an entire year. Using NRELs high-performance computing capabilities and new methodologies to model operations, we found that the EI, as simulated with evolutionary change in 2026, could balance the variability and uncertainty of wind and PV at a 5-minute level under a variety of conditions. A large-scale display and a combination of multiple coordinated views and small multiples were used to visually analyze the four large highly multivariate scenarios with high spatial and temporal resolutions.« less

  1. Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

    PubMed Central

    Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J.; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo

    2016-01-01

    Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications. PMID:27147324

  2. Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications.

    PubMed

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo

    2016-05-01

    High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

  3. High-Resolution in Situ Measurement of Nitrate in Runoff from the Greenland Ice Sheet.

    PubMed

    Beaton, Alexander D; Wadham, Jemma L; Hawkings, Jon; Bagshaw, Elizabeth A; Lamarche-Gagnon, Guillaume; Mowlem, Matthew C; Tranter, Martyn

    2017-11-07

    We report the first in situ high-resolution nitrate time series from two proglacial meltwater rivers draining the Greenland Ice Sheet, using a recently developed submersible analyzer based on lab-on-chip (LOC) technology. The low sample volume (320 μL) required by the LOC analyzer meant that low concentration (few micromolar to submicromolar), highly turbid subglacial meltwater could be filtered and colorimetrically analyzed in situ. Nitrate concentrations in rivers draining Leverett Glacier in southwest Greenland and Kiattuut Sermiat in southern Greenland exhibited a clear diurnal signal and a gradual decline at the commencement of the melt season, displaying trends that would not be discernible using traditional daily manual sampling. Nitrate concentrations varied by 4.4 μM (±0.2 μM) over a 10 day period at Kiattuut Sermiat and 3.0 μM (±0.2 μM) over a 14 day period at Leverett Glacier. Marked changes in nitrate concentrations were observed when discharge began to increase. High-resolution in situ measurements such as these have the potential to significantly advance the understanding of nutrient cycling in remote systems, where the dynamics of nutrient release are complex but are important for downstream biogeochemical cycles.

  4. Wavelength Coded Image Transmission and Holographic Optical Elements.

    DTIC Science & Technology

    1984-08-20

    system has been designed and built for transmitting images of diffusely reflecting objects through optical fibers and displaying those images at a...passive components at the end of a fiber-optic designed to transmit high-resolution images of diffusely imaging system as described in this paper... designing a system for viewing diffusely reflecting The authors are with University of Minnesota. Electrical Engi- objects, one must consider that a

  5. Electron Energy Distribution and Transfer Phenomena in Non-Equilibrium Gases

    DTIC Science & Technology

    2016-09-01

    and quantitative determination of species difficult. In a mass spectrometry study on boron chemistry a few decade ago, a technique of isotopic...In this FTMS study on TEB, by means of the high-mass-resolution spectrum to distinguish the isobaric ions, we have identified and quantitatively ...reproduce, release, perform, display, or disclose the work. 14. ABSTRACT During this 3-year in-house experimental research task, researchers in the

  6. Developing a novel UAV (Unmanned Aerial Vehicle) helicopter platform for very high resolution environmental monitoring of catchment processes

    NASA Astrophysics Data System (ADS)

    Freer, J.; Richardson, T. S.

    2012-04-01

    Recent advances in remote sensing and geographic information has led the way for the development of hyperspectral sensors and cloud scanning LIDAR (Light Detection And Ranging). Both these technologies can be used to sense environmental processes and capture detailed spatial information, they are often deployed in ground, aircraft and satellite based systems. Hyperspectral remote sensing, also known as imaging spectroscopy, is a relatively new technology that is currently being investigated by researchers and scientists with regard to the detection and identification of landscapes, terrestrial vegetation, and manmade materials and backgrounds. There are many applications that could take advantages of hyperspectral remote sensing coupled to detailed surface feature mapping using LIDAR. This embryonic project involves developing the engineering solutions and post processing techniques needed to realise an ultra high resolution helicopter based environmental sensing platform which can fly at lower altitudes than aircraft systems and can be deployed more frequently. We aim to display this new technology platform in this special session (the only one of it's kind in the UK). Initial applications are planned on a range of environmental sensing problems that would benefit from such complex and detailed data. We look forward to being able to display and discuss this initiative with colleagues and any potential interest in future collaborative projects.

  7. High Spatial Resolution Europa Coverage by the Galileo Near Infrared Mapping Spectrometer (NIMS)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The NIMS instrument on the Galileo spacecraft, which is being used to map the mineral and ice properties over the surfaces of the Jovian moons, produces global spectral images at modest spatial resolution and high resolution spectral images for small selected regions on the satellites. This map illustrates the high resolution coverage of Europa obtained by NIMS through the April 1997 G7 orbit.

    The areas covered are displayed on a Voyager-derived map. A good sampling of the dark trailing-side material (180 to 360 degrees) has been obtained, with less coverage of Europa's leading side.

    The false-color composites use red, green and blue to represent the infrared brightnesses at 0.7, 1.51 and 1.82 microns respectively. Considerable variations are evident and are related to the composition and sizes of the surface grains.

    The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.

    The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.

    This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov.

  8. Metrics for the Diurnal Cycle of Precipitation: Toward Routine Benchmarks for Climate Models

    DOE PAGES

    Covey, Curt; Gleckler, Peter J.; Doutriaux, Charles; ...

    2016-06-08

    In this paper, metrics are proposed—that is, a few summary statistics that condense large amounts of data from observations or model simulations—encapsulating the diurnal cycle of precipitation. Vector area averaging of Fourier amplitude and phase produces useful information in a reasonably small number of harmonic dial plots, a procedure familiar from atmospheric tide research. The metrics cover most of the globe but down-weight high-latitude wintertime ocean areas where baroclinic waves are most prominent. This enables intercomparison of a large number of climate models with observations and with each other. The diurnal cycle of precipitation has features not encountered in typicalmore » climate model intercomparisons, notably the absence of meaningful “average model” results that can be displayed in a single two-dimensional map. Displaying one map per model guides development of the metrics proposed here by making it clear that land and ocean areas must be averaged separately, but interpreting maps from all models becomes problematic as the size of a multimodel ensemble increases. Global diurnal metrics provide quick comparisons with observations and among models, using the most recent version of the Coupled Model Intercomparison Project (CMIP). This includes, for the first time in CMIP, spatial resolutions comparable to global satellite observations. Finally, consistent with earlier studies of resolution versus parameterization of the diurnal cycle, the longstanding tendency of models to produce rainfall too early in the day persists in the high-resolution simulations, as expected if the error is due to subgrid-scale physics.« less

  9. Metrics for the Diurnal Cycle of Precipitation: Toward Routine Benchmarks for Climate Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Covey, Curt; Gleckler, Peter J.; Doutriaux, Charles

    In this paper, metrics are proposed—that is, a few summary statistics that condense large amounts of data from observations or model simulations—encapsulating the diurnal cycle of precipitation. Vector area averaging of Fourier amplitude and phase produces useful information in a reasonably small number of harmonic dial plots, a procedure familiar from atmospheric tide research. The metrics cover most of the globe but down-weight high-latitude wintertime ocean areas where baroclinic waves are most prominent. This enables intercomparison of a large number of climate models with observations and with each other. The diurnal cycle of precipitation has features not encountered in typicalmore » climate model intercomparisons, notably the absence of meaningful “average model” results that can be displayed in a single two-dimensional map. Displaying one map per model guides development of the metrics proposed here by making it clear that land and ocean areas must be averaged separately, but interpreting maps from all models becomes problematic as the size of a multimodel ensemble increases. Global diurnal metrics provide quick comparisons with observations and among models, using the most recent version of the Coupled Model Intercomparison Project (CMIP). This includes, for the first time in CMIP, spatial resolutions comparable to global satellite observations. Finally, consistent with earlier studies of resolution versus parameterization of the diurnal cycle, the longstanding tendency of models to produce rainfall too early in the day persists in the high-resolution simulations, as expected if the error is due to subgrid-scale physics.« less

  10. Global behavior of the height/seasonal structure of tides between 40 deg and 60 deg latitude

    NASA Technical Reports Server (NTRS)

    Manson, A. H.; Meek, C. E.; Teitelbaum, H.; Fraser, G. J.; Smith, M. J.; Clark, R. R.; Schminder, R.; Kuerschner, D.

    1989-01-01

    The radars utilized are meteor (2), medium frequency (2) and the new low frequency (1) systems: analysis techniques were exhaustively studied internally and comparatively and are not thought to affect the results. Emphasis is placed upon the new height-time contours of 24-, 12-h tidal amplitudes and phases, which best display height and seasonal structures; where possible high resolution (10 d) is used (Saskatoon), but all stations provide monthly mean resolution. At these latitudes the diurnal tide is generally smaller than the semidiurnal, and displays more variability. However, there is a tendency for vertical wavelengths and amplitudes to be larger during summer months. On occasions in winter and fall, wavelengths may be less than 50 km. The dominant semidiurnal tide shows significant regular season structure; wavelengths are generally small (about 50 km) in winter, large in summer (equal to or greater than 100 km), and these states are separated by rapid equinoctial transitions. There is some evidence for less regularity toward 40 deg. Coupling with mean winds is apparent. Data from earlier ATMAP campaigns are mentioned, and reasons for their inadequacies presented.

  11. How colorful! A feature it is, isn't it?

    NASA Astrophysics Data System (ADS)

    Lebowsky, Fritz

    2015-01-01

    A display's color subpixel geometry provides an intriguing opportunity for improving readability of text. True type fonts can be positioned at the precision of subpixel resolution. With such a constraint in mind, how does one need to design font characteristics? On the other hand, display manufactures try hard in addressing the color display's dilemma: smaller pixel pitch and larger display diagonals strongly increase the total number of pixels. Consequently, cost of column and row drivers as well as power consumption increase. Perceptual color subpixel rendering using color component subsampling may save about 1/3 of color subpixels (and reduce power dissipation). This talk will try to elaborate the following questions, based on simulation of several different layouts of subpixel matrices: Up to what level are display device constraints compatible with software specific ideas of rendering text? How much of color contrast will remain? How to best consider preferred viewing distance for readability of text? How much does visual acuity vary at 20/20 vision? Can simplified models of human visual color perception be easily applied to text rendering on displays? How linear is human visual contrast perception around band limit of a display's spatial resolution? How colorful does the rendered text appear on the screen? How much does viewing angle influence the performance of subpixel layouts and color subpixel rendering?

  12. High-resolution multi-model projections of onshore wind resources over Portugal under a changing climate

    NASA Astrophysics Data System (ADS)

    Nogueira, Miguel; Soares, Pedro M. M.; Tomé, Ricardo; Cardoso, Rita M.

    2018-05-01

    We present a detailed evaluation of wind energy density (WED) over Portugal, based on the EURO-CORDEX database of high-resolution regional climate model (RCM) simulations. Most RCMs showed reasonable accuracy in reproducing the observed near-surface wind speed. The climatological patterns of WED displayed large sub-regional heterogeneity, with higher values over coastal regions and steep orography. Subsequently, we investigated the future changes of WED throughout the twenty-first century, considering mid- and end-century periods, and two emission scenarios (RCP4.5 and RCP8.5). On the yearly average, the multi-model ensemble WED changes were below 10% (15%) under RCP4.5 (RCP8.5). However, the projected WED anomalies displayed strong seasonality, dominated by low positive values in summer (< 10% for both scenarios), negative values in winter and spring (up to - 10% (- 20%) under RCP4.5 (RCP8.5)), and stronger negative anomalies in autumn (up to - 25% (- 35%) under RCP4.5 (RCP8.5)). These projected WED anomalies displayed large sub-regional variability. The largest reductions (and lowest increases) are linked to the northern and central-eastern elevated terrain, and the southwestern coast. In contrast, the largest increases (and lowest reductions) are linked to the central-western orographic features of moderate elevation. The projections also showed changes in inter-annual variability of WED, with small increases for annual averages, but with distinct behavior when considering year-to-year variability over a specific season: small increases in winter, larger increases in summer, slight decrease in autumn, and no relevant change in spring. The changes in inter-annual variability also displayed strong dependence on the underlying terrain. Finally, we found significant model spread in the magnitude of projected WED anomalies and inter-annual variability, affecting even the signal of the changes.

  13. Color calibration of liquid crystal displays

    NASA Astrophysics Data System (ADS)

    Cazes, Albert N.; Braudaway, Gordon W.; Christensen, James; Cordes, Michael; DeCain, Don; Lien, Shui-Chih A.; Mintzer, Frederick C.; Wright, Steven L.

    1999-04-01

    For more than a decade the Image Applications department at IBMs Watson Research Center has been involved in cultural and commercial imaging projects that demand high-fidelity color reproduction of precious objects like paintings, illuminated manuscripts or jewelry. Our primary display media have been high-resolution cathode ray tubes (CRT), but for the last three years our customers have been replacing them with liquid crystal displays (LCD). The color calibration model we have been using for the CRT is the one described in the literature. It assumes that the chromas of the primaries are independent of intensity, that the colors produced from them are additive and that the intensity of black is almost zero. We measured several models of LCDs and observed that they poorly satisfied these assumptions at medium to low intensities. This becomes noticeable if the image has dark areas or if the display is viewed under a weak ambient light. In this paper, we use a modified version of the CRT model to calibrate the LCD. First we measure four sets of red, green, blue and gray patches. THen we determine the correction factor needed to make, at each level,the sum of the primaries equal to the corresponding gray. Finally, we use these factors to modify the data of red, green and blue.

  14. Hard copies for digital medical images: an overview

    NASA Astrophysics Data System (ADS)

    Blume, Hartwig R.; Muka, Edward

    1995-04-01

    This paper is a condensed version of an invited overview on the technology of film hard-copies used in radiology. Because the overview was given to an essentially nonmedical audience, the reliance on film hard-copies in radiology is outlined in greater detail. The overview is concerned with laser image recorders generating monochrome prints on silver-halide films. The basic components of laser image recorders are sketched. The paper concentrates on the physical parameters - characteristic function, dynamic range, digitization resolution, modulation transfer function, and noise power spectrum - which define image quality and information transfer capability of the printed image. A preliminary approach is presented to compare the printed image quality with noise in the acquired image as well as with the noise of state-of- the-art cathode-ray-tube display systems. High-performance laser-image- recorder/silver-halide-film/light-box systems are well capable of reproducing acquired radiologic information. Most recently development was begun toward a display function standard for soft-copy display systems to facilitate similarity of image presentation between different soft-copy displays as well as between soft- and hard-copy displays. The standard display function is based on perceptional linearization. The standard is briefly reviewed to encourage the printer industry to adopt it, too.

  15. Symbology Development for General Aviation Synthetic Vision Primary Flight Displays for the Approach and Missed-Approach Modes of Flight

    NASA Technical Reports Server (NTRS)

    Bartolone, Anthony P.; Hughes, Monica F.; Wong, Douglas T.; Takallu, Mohammad A.

    2004-01-01

    Spatial disorientation induced by inadvertent flight into instrument meteorological conditions (IMC) continues to be a leading cause of fatal accidents in general aviation. The Synthetic Vision Systems General Aviation (SVS-GA) research element, an integral part of NASA s Aviation Safety and Security Program (AvSSP), is investigating a revolutionary display technology designed to mitigate low visibility events such as controlled flight into terrain (CFIT) and low-visibility loss of control (LVLoC). The integrated SVS Primary Flight Display (SVS-PFD) utilizes computer generated 3-dimensional imagery of the surrounding terrain augmented with flight path guidance symbology. This unique combination will provide GA pilots with an accurate representation of their environment and projection of their flight path, regardless of time of day or out-the-window (OTW) visibility. The initial Symbology Development for Head-Down Displays (SD-HDD) simulation experiment examined 16 display configurations on a centrally located high-resolution PFD installed in NASA s General Aviation Work Station (GAWS) flight simulator. The results of the experiment indicate that situation awareness (SA) can be enhanced without having a negative impact on flight technical error (FTE), by providing a general aviation pilot with an integrated SVS display to use when OTW visibility is obscured.

  16. Tomato bushy stunt virus (TBSV), a versatile platform for polyvalent display of antigenic epitopes and vaccine design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Shantanu; Ochoa, Wendy; Singh, Pratik

    2009-05-25

    Viruses-like particles (VLPs) are frequently being used as platforms for polyvalent display of foreign epitopes of interest on their capsid surface to improve their presentation enhancing the antigenicity and host immune response. In the present study, we used the VLPs of Tomato bushy stunt virus (TBSV), an icosahedral plant virus, as a platform to display 180 copies of 16 amino acid epitopes of ricin toxin fused to the C-terminal end of a modified TBSV capsid protein (NDELTA52). Expression of the chimeric recombinant protein in insect cells resulted in spontaneous assembly of VLPs displaying the ricin epitope. Cryo-electron microscopy and imagemore » reconstruction of the chimeric VLPs at 22 A resolution revealed the locations and orientation of the ricin epitope exposed on the TBSV capsid surface. Furthermore, injection of chimeric VLPs into mice generated antisera that detected the native ricin toxin. The ease of fusing of short peptides of 15-20 residues and their ability to form two kinds (T = 1, T = 3) of bio-nanoparticles that result in the display of 60 or 180 copies of less constrained and highly exposed antigenic epitopes makes TBSV an attractive and versatile display platform for vaccine design.« less

  17. Migration of the digital interactive breast-imaging teaching file

    NASA Astrophysics Data System (ADS)

    Cao, Fei; Sickles, Edward A.; Huang, H. K.; Zhou, Xiaoqiang

    1998-06-01

    The digital breast imaging teaching file developed during the last two years in our laboratory has been used successfully at UCSF (University of California, San Francisco) as a routine teaching tool for training radiology residents and fellows in mammography. Building on this success, we have ported the teaching file from an old Pixar imaging/Sun SPARC 470 display system to our newly designed telemammography display workstation (Ultra SPARC 2 platform with two DOME Md5/SBX display boards). The old Pixar/Sun 470 system, although adequate for fast and high-resolution image display, is 4- year-old technology, expensive to maintain and difficult to upgrade. The new display workstation is more cost-effective and is also compatible with the digital image format from a full-field direct digital mammography system. The digital teaching file is built on a sophisticated computer-aided instruction (CAI) model, which simulates the management sequences used in imaging interpretation and work-up. Each user can be prompted to respond by making his/her own observations, assessments, and work-up decisions as well as the marking of image abnormalities. This effectively replaces the traditional 'show-and-tell' teaching file experience with an interactive, response-driven type of instruction.

  18. Development of a Low Cost Graphics Terminal.

    ERIC Educational Resources Information Center

    Lehr, Ted

    1985-01-01

    Describes modifications made to expand the capabilities of a display unit (Lear Siegler ADM-3A) to include medium resolution graphics. The modifying circuitry is detailed along with software subroutined written in Z-80 machine language for controlling the video display. (JN)

  19. Data graphing methods, articles of manufacture, and computing devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, Pak Chung; Mackey, Patrick S.; Cook, Kristin A.

    Data graphing methods, articles of manufacture, and computing devices are described. In one aspect, a method includes accessing a data set, displaying a graphical representation including data of the data set which is arranged according to a first of different hierarchical levels, wherein the first hierarchical level represents the data at a first of a plurality of different resolutions which respectively correspond to respective ones of the hierarchical levels, selecting a portion of the graphical representation wherein the data of the portion is arranged according to the first hierarchical level at the first resolution, modifying the graphical representation by arrangingmore » the data of the portion according to a second of the hierarchal levels at a second of the resolutions, and after the modifying, displaying the graphical representation wherein the data of the portion is arranged according to the second hierarchal level at the second resolution.« less

  20. Lens-based wavefront sensorless adaptive optics swept source OCT

    NASA Astrophysics Data System (ADS)

    Jian, Yifan; Lee, Sujin; Ju, Myeong Jin; Heisler, Morgan; Ding, Weiguang; Zawadzki, Robert J.; Bonora, Stefano; Sarunic, Marinko V.

    2016-06-01

    Optical coherence tomography (OCT) has revolutionized modern ophthalmology, providing depth resolved images of the retinal layers in a system that is suited to a clinical environment. Although the axial resolution of OCT system, which is a function of the light source bandwidth, is sufficient to resolve retinal features at a micrometer scale, the lateral resolution is dependent on the delivery optics and is limited by ocular aberrations. Through the combination of wavefront sensorless adaptive optics and the use of dual deformable transmissive optical elements, we present a compact lens-based OCT system at an imaging wavelength of 1060 nm for high resolution retinal imaging. We utilized a commercially available variable focal length lens to correct for a wide range of defocus commonly found in patient’s eyes, and a novel multi-actuator adaptive lens for aberration correction to achieve near diffraction limited imaging performance at the retina. With a parallel processing computational platform, high resolution cross-sectional and en face retinal image acquisition and display was performed in real time. In order to demonstrate the system functionality and clinical utility, we present images of the photoreceptor cone mosaic and other retinal layers acquired in vivo from research subjects.

  1. Detection performance in clutter with variable resolution

    NASA Astrophysics Data System (ADS)

    Schmieder, D. E.; Weathersby, M. R.

    1983-07-01

    Experiments were conducted to determine the influence of background clutter on target detection criteria. The experiment consisted of placing observers in front of displayed images on a TV monitor. Observer ability to detect military targets embedded in simulated natural and manmade background clutter was measured when there was unlimited viewing time. Results were described in terms of detection probability versus target resolution for various signal to clutter ratios (SCR). The experiments were preceded by a search for a meaningful clutter definition. The selected definition was a statistical measure computed by averaging the standard deviation of contiguous scene cells over the whole scene. The cell size was comparable to the target size. Observer test results confirmed the expectation that the resolution required for a given detection probability was a continuum function of the clutter level. At the lower SCRs the resolution required for a high probability of detection was near 6 line pairs per target (LP/TGT), while at the higher SCRs it was found that a resoluton of less than 0.25 LP/TGT would yield a high probability of detection. These results are expected to aid in target acquisition performance modeling and to lead to improved specifications for imaging automatic target screeners.

  2. An Experiment Quantifying The Effect Of Clutter On Target Detection

    NASA Astrophysics Data System (ADS)

    Weathersby, Marshall R.; Schmieder, David E.

    1985-01-01

    Experiments were conducted to determine the influence of background clutter on target detection criteria. The experiment consisted of placing observers in front of displayed images on a TV monitor. Observer ability to detect military targets embedded in simulated natural and manmade background clutter was measured when there was unlimited viewing time. Results were described in terms of detection probability versus target resolution for various signal to clutter ratios (SCR). The experiments were preceded by a search for a meaningful clutter definition. The selected definition was a statistical measure computed by averaging the standard deviation of contiguous scene cells over the whole scene. The cell size was comparable to the target size. Observer test results confirmed the expectation that the resolution required for a given detection probability was a continuum function of the clutter level. At the lower SCRs the resolution required for a high probability of detection was near 6 lines pairs per target (LP/TGT), while at the higher SCRs it was found that a resolution of less than 0.25 LP/TGT would yield a high probability of detection. These results are expected to aid in target acquisition performance modeling and to lead to improved specifications for imaging automatic target screeners.

  3. Serial Femtosecond Crystallography of G Protein-Coupled Receptors

    PubMed Central

    Liu, Wei; Wacker, Daniel; Gati, Cornelius; Han, Gye Won; James, Daniel; Wang, Dingjie; Nelson, Garrett; Weierstall, Uwe; Katritch, Vsevolod; Barty, Anton; Zatsepin, Nadia A.; Li, Dianfan; Messerschmidt, Marc; Boutet, Sébastien; Williams, Garth J.; Koglin, Jason E.; Seibert, M. Marvin; Wang, Chong; Shah, Syed T.A.; Basu, Shibom; Fromme, Raimund; Kupitz, Christopher; Rendek, Kimberley N.; Grotjohann, Ingo; Fromme, Petra; Kirian, Richard A.; Beyerlein, Kenneth R.; White, Thomas A.; Chapman, Henry N.; Caffrey, Martin; Spence, John C.H.; Stevens, Raymond C.; Cherezov, Vadim

    2014-01-01

    X-ray crystallography of G protein-coupled receptors and other membrane proteins is hampered by difficulties associated with growing sufficiently large crystals that withstand radiation damage and yield high-resolution data at synchrotron sources. Here we used an x-ray free-electron laser (XFEL) with individual 50-fs duration x-ray pulses to minimize radiation damage and obtained a high-resolution room temperature structure of a human serotonin receptor using sub-10 µm microcrystals grown in a membrane mimetic matrix known as lipidic cubic phase. Compared to the structure solved by traditional microcrystallography from cryo-cooled crystals of about two orders of magnitude larger volume, the room temperature XFEL structure displays a distinct distribution of thermal motions and conformations of residues that likely more accurately represent the receptor structure and dynamics in a cellular environment. PMID:24357322

  4. A theoretical and experimental benchmark study of core-excited states in nitrogen

    DOE PAGES

    Myhre, Rolf H.; Wolf, Thomas J. A.; Cheng, Lan; ...

    2018-02-14

    The high resolution near edge X-ray absorption fine structure spectrum of nitrogen displays the vibrational structure of the core-excited states. This makes nitrogen well suited for assessing the accuracy of different electronic structure methods for core excitations. We report high resolution experimental measurements performed at the SOLEIL synchrotron facility. These are compared with theoretical spectra calculated using coupled cluster theory and algebraic diagrammatic construction theory. The coupled cluster singles and doubles with perturbative triples model known as CC3 is shown to accurately reproduce the experimental excitation energies as well as the spacing of the vibrational transitions. In conclusion, the computationalmore » results are also shown to be systematically improved within the coupled cluster hierarchy, with the coupled cluster singles, doubles, triples, and quadruples method faithfully reproducing the experimental vibrational structure.« less

  5. Improved high-resolution ultrasonic imaging of the eye.

    PubMed

    Silverman, Ronald H; Ketterling, Jeffrey A; Mamou, Jonathan; Coleman, D Jackson

    2008-01-01

    Currently, virtually all clinical diagnostic ultrasound systems used in ophthalmology are based on fixed-focus, single-element transducers. High-frequency (> or = 20-MHz) transducers introduced to ophthalmology during the last decade have led to improved resolution and diagnostic capabilities for assessment of the anterior segment and the retina. However, single-element transducers are restricted to a small depth of field, limiting their capacity to image the eye as a whole. We fabricated a 20-MHz annular array probe prototype consisting of 5 concentric transducer elements and scanned an ex vivo human eye. Synthetically focused images of the bank eye showed improved depth of field and sensitivity, allowing simultaneous display of the anterior and posterior segments and the full lens contour. This capability may be useful in assessment of vitreoretinal pathologies and investigation of the accommodative mechanism.

  6. A theoretical and experimental benchmark study of core-excited states in nitrogen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myhre, Rolf H.; Wolf, Thomas J. A.; Cheng, Lan

    The high resolution near edge X-ray absorption fine structure spectrum of nitrogen displays the vibrational structure of the core-excited states. This makes nitrogen well suited for assessing the accuracy of different electronic structure methods for core excitations. We report high resolution experimental measurements performed at the SOLEIL synchrotron facility. These are compared with theoretical spectra calculated using coupled cluster theory and algebraic diagrammatic construction theory. The coupled cluster singles and doubles with perturbative triples model known as CC3 is shown to accurately reproduce the experimental excitation energies as well as the spacing of the vibrational transitions. In conclusion, the computationalmore » results are also shown to be systematically improved within the coupled cluster hierarchy, with the coupled cluster singles, doubles, triples, and quadruples method faithfully reproducing the experimental vibrational structure.« less

  7. Using MODIS Terra 250 m Imagery to Map Concentrations of Total Suspended Matter in Coastal Waters

    NASA Technical Reports Server (NTRS)

    Miller, Richard L.; McKee, Brent A.

    2004-01-01

    High concentrations of suspended particulate matter in coastal waters directly effect or govern numerous water column and benthic processes. The concentration of suspended sediments derived from bottom sediment resuspension or discharge of sediment-laden rivers is highly variable over a wide range of time and space scales. Although there has been considerable effort to use remotely sensed images to provide synoptic maps of suspended particulate matter, there are limited routine applications of this technology due in-part to the low spatial resolution, long revisit period, or cost of most remotely sensed data. In contrast, near daily coverage of medium-resolution data is available from the MODIS Terra instrument without charge from several data distribution gateways. Equally important, several display and processing programs are available that operate on low cost computers.

  8. Ultra-high resolution and high-brightness AMOLED

    NASA Astrophysics Data System (ADS)

    Wacyk, Ihor; Ghosh, Amal; Prache, Olivier; Draper, Russ; Fellowes, Dave

    2012-06-01

    As part of its continuing effort to improve both the resolution and optical performance of AMOLED microdisplays, eMagin has recently developed an SXGA (1280×3×1024) microdisplay under a US Army RDECOM CERDEC NVESD contract that combines the world's smallest OLED pixel pitch with an ultra-high brightness green OLED emitter. This development is aimed at next-generation HMD systems with "see-through" and daylight imaging requirements. The OLED pixel array is built on a 0.18-micron CMOS backplane and contains over 4 million individually addressable pixels with a pixel pitch of 2.7 × 8.1 microns, resulting in an active area of 0.52 inches diagonal. Using both spatial and temporal enhancement, the display can provide over 10-bits of gray-level control for high dynamic range applications. The new pixel design also enables the future implementation of a full-color QSXGA (2560 × RGB × 2048) microdisplay in an active area of only 1.05 inch diagonal. A low-power serialized low-voltage-differential-signaling (LVDS) interface is integrated into the display for use as a remote video link for tethered systems. The new SXGA backplane has been combined with the high-brightness green OLED device developed by eMagin under an NVESD contract. This OLED device has produced an output brightness of more than 8000fL with all pixels on; lifetime measurements are currently underway and will presented at the meeting. This paper will describe the operational features and first optical and electrical test results of the new SXGA demonstrator microdisplay.

  9. Flatbed-type 3D display systems using integral imaging method

    NASA Astrophysics Data System (ADS)

    Hirayama, Yuzo; Nagatani, Hiroyuki; Saishu, Tatsuo; Fukushima, Rieko; Taira, Kazuki

    2006-10-01

    We have developed prototypes of flatbed-type autostereoscopic display systems using one-dimensional integral imaging method. The integral imaging system reproduces light beams similar of those produced by a real object. Our display architecture is suitable for flatbed configurations because it has a large margin for viewing distance and angle and has continuous motion parallax. We have applied our technology to 15.4-inch displays. We realized horizontal resolution of 480 with 12 parallaxes due to adoption of mosaic pixel arrangement of the display panel. It allows viewers to see high quality autostereoscopic images. Viewing the display from angle allows the viewer to experience 3-D images that stand out several centimeters from the surface of the display. Mixed reality of virtual 3-D objects and real objects are also realized on a flatbed display. In seeking reproduction of natural 3-D images on the flatbed display, we developed proprietary software. The fast playback of the CG movie contents and real-time interaction are realized with the aid of a graphics card. Realization of the safety 3-D images to the human beings is very important. Therefore, we have measured the effects on the visual function and evaluated the biological effects. For example, the accommodation and convergence were measured at the same time. The various biological effects are also measured before and after the task of watching 3-D images. We have found that our displays show better results than those to a conventional stereoscopic display. The new technology opens up new areas of application for 3-D displays, including arcade games, e-learning, simulations of buildings and landscapes, and even 3-D menus in restaurants.

  10. Can Effective Synthetic Vision System Displays be Implemented on Limited Size Display Spaces?

    NASA Technical Reports Server (NTRS)

    Comstock, J. Raymond, Jr.; Glaab, Lou J.; Prinzel, Lance J.; Elliott, Dawn M.

    2004-01-01

    The Synthetic Vision Systems (SVS) element of the NASA Aviation Safety Program is striving to eliminate poor visibility as a causal factor in aircraft accidents, and to enhance operational capabilities of all types or aircraft. To accomplish these safety and situation awareness improvements, the SVS concepts are designed to provide a clear view of the world ahead through the display of computer generated imagery derived from an onboard database of terrain, obstacle and airport information. An important issue for the SVS concept is whether useful and effective Synthetic Vision System (SVS) displays can be implemented on limited size display spaces as would be required to implement this technology on older aircraft with physically smaller instrument spaces. In this study, prototype SVS displays were put on the following display sizes: (a) size "A' (e.g. 757 EADI), (b) form factor "D" (e.g. 777 PFD), and (c) new size "X" (Rectangular flat-panel, approximately 20 x 25 cm). Testing was conducted in a high-resolution graphics simulation facility at NASA Langley Research Center. Specific issues under test included the display size as noted above, the field-of-view (FOV) to be shown on the display and directly related to FOV is the degree of minification of the displayed image or picture. Using simulated approaches with display size and FOV conditions held constant no significant differences by these factors were found. Preferred FOV based on performance was determined by using approaches during which pilots could select FOV. Mean preference ratings for FOV were in the following order: (1) 30 deg., (2) Unity, (3) 60 deg., and (4) 90 deg., and held true for all display sizes tested. Limitations of the present study and future research directions are discussed.

  11. Identification and super-resolution imaging of ligand-activated receptor dimers in live cells

    NASA Astrophysics Data System (ADS)

    Winckler, Pascale; Lartigue, Lydia; Giannone, Gregory; de Giorgi, Francesca; Ichas, François; Sibarita, Jean-Baptiste; Lounis, Brahim; Cognet, Laurent

    2013-08-01

    Molecular interactions are key to many chemical and biological processes like protein function. In many signaling processes they occur in sub-cellular areas displaying nanoscale organizations and involving molecular assemblies. The nanometric dimensions and the dynamic nature of the interactions make their investigations complex in live cells. While super-resolution fluorescence microscopies offer live-cell molecular imaging with sub-wavelength resolutions, they lack specificity for distinguishing interacting molecule populations. Here we combine super-resolution microscopy and single-molecule Förster Resonance Energy Transfer (FRET) to identify dimers of receptors induced by ligand binding and provide super-resolved images of their membrane distribution in live cells. By developing a two-color universal-Point-Accumulation-In-the-Nanoscale-Topography (uPAINT) method, dimers of epidermal growth factor receptors (EGFR) activated by EGF are studied at ultra-high densities, revealing preferential cell-edge sub-localization. This methodology which is specifically devoted to the study of molecules in interaction, may find other applications in biological systems where understanding of molecular organization is crucial.

  12. Calibration of medium-resolution monochrome cathode ray tube displays for the purpose of board examinations.

    PubMed

    Evanoff, M G; Roehrig, H; Giffords, R S; Capp, M P; Rovinelli, R J; Hartmann, W H; Merritt, C

    2001-06-01

    This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.

  13. Modelling and observations of molecules in discs around young stars

    NASA Astrophysics Data System (ADS)

    Ilee, John David

    2013-04-01

    This thesis contains a study of molecules within circumstellar discs around young stars. Firstly, the chemistry of a disc around a young, Class 0 protostar is modelled. Such discs are thought to be massive, and thus experience gravitational instabilities, which produce spiral density waves. These affect the chemistry in three ways; by desorbing molecules from dust grains, by providing extra energy for new reactions to take place, and by mixing the internal structure of the disc to provide a rich chemistry near the midplane. Secondly, high resolution near-infrared spectra of 20 massive young stellar objects are presented. The objects display CO first overtone bandhead emission, which is excited in the conditions expected within circumstellar discs. The emission is modelled using a simple analytic model of a Keplerian disc, and good fits are found to all spectra. On average, the discs correspond to being geometrically thin, spread across a wide range of inclinations. The discs are located within the dust sublimation radius, providing strong evidence that the CO emission originates in small gaseous discs, supporting the scenario in which massive stars form via disc accretion. Finally, medium resolution near-infrared spectra of 5 Herbig Ae/Be stars are presented. The spectra cover both CO bandhead and Br gamma emission. Accretion rates are derived from the measuring the Br gamma emission and through modelling the CO emission, however these accretion rates are found to be inconsistent. High resolution archival data of one of the targets is presented, and it is shown that this CO disc model is unable to fit the high resolution data. Therefore, it is concluded that to properly fit CO spectra, high resolution data are needed, and that previously published information determined from low resolution spectra should be treated with caution.

  14. How high is visual short-term memory capacity for object layout?

    PubMed

    Sanocki, Thomas; Sellers, Eric; Mittelstadt, Jeff; Sulman, Noah

    2010-05-01

    Previous research measuring visual short-term memory (VSTM) suggests that the capacity for representing the layout of objects is fairly high. In four experiments, we further explored the capacity of VSTM for layout of objects, using the change detection method. In Experiment 1, participants retained most of the elements in displays of 4 to 8 elements. In Experiments 2 and 3, with up to 20 elements, participants retained many of them, reaching a capacity of 13.4 stimulus elements. In Experiment 4, participants retained much of a complex naturalistic scene. In most cases, increasing display size caused only modest reductions in performance, consistent with the idea of configural, variable-resolution grouping. The results indicate that participants can retain a substantial amount of scene layout information (objects and locations) in short-term memory. We propose that this is a case of remote visual understanding, where observers' ability to integrate information from a scene is paramount.

  15. High precision, fast ultrasonic thermometer based on measurement of the speed of sound in air

    NASA Astrophysics Data System (ADS)

    Huang, K. N.; Huang, C. F.; Li, Y. C.; Young, M. S.

    2002-11-01

    This study presents a microcomputer-based ultrasonic system which measures air temperature by detecting variations in the speed of sound in the air. Changes in the speed of sound are detected by phase shift variations of a 40 kHz continuous ultrasonic wave. In a test embodiment, two 40 kHz ultrasonic transducers are set face to face at a constant distance. Phase angle differences between transmitted and received signals are determined by a FPGA digital phase detector and then analyzed in an 89C51 single-chip microcomputer. Temperature is calculated and then sent to a LCD display and, optionally, to a PC. Accuracy of measurement is within 0.05 degC at an inter-transducer distance of 10 cm. Temperature variations are displayed within 10 ms. The main advantages of the proposed system are high resolution, rapid temperature measurement, noncontact measurement and easy implementation.

  16. Advanced GPR imaging of sedimentary features: integrated attribute analysis applied to sand dunes

    NASA Astrophysics Data System (ADS)

    Zhao, Wenke; Forte, Emanuele; Fontolan, Giorgio; Pipan, Michele

    2018-04-01

    We evaluate the applicability and the effectiveness of integrated GPR attribute analysis to image the internal sedimentary features of the Piscinas Dunes, SW Sardinia, Italy. The main objective is to explore the limits of GPR techniques to study sediment-bodies geometry and to provide a non-invasive high-resolution characterization of the different subsurface domains of dune architecture. On such purpose, we exploit the high-quality Piscinas data-set to extract and test different attributes of the GPR trace. Composite displays of multi-attributes related to amplitude, frequency, similarity and textural features are displayed with overlays and RGB mixed models. A multi-attribute comparative analysis is used to characterize different radar facies to better understand the characteristics of internal reflection patterns. The results demonstrate that the proposed integrated GPR attribute analysis can provide enhanced information about the spatial distribution of sediment bodies, allowing an enhanced and more constrained data interpretation.

  17. Projection displays and MEMS: timely convergence for a bright future

    NASA Astrophysics Data System (ADS)

    Hornbeck, Larry J.

    1995-09-01

    Projection displays and microelectromechanical systems (MEMS) have evolved independently, occasionally crossing paths as early as the 1950s. But the commercially viable use of MEMS for projection displays has been illusive until the recent invention of Texas Instruments Digital Light Processing TM (DLP) technology. DLP technology is based on the Digital Micromirror DeviceTM (DMD) microchip, a MEMS technology that is a semiconductor digital light switch that precisely controls a light source for projection display and hardcopy applications. DLP technology provides a unique business opportunity because of the timely convergence of market needs and technology advances. The world is rapidly moving to an all- digital communications and entertainment infrastructure. In the near future, most of the technologies necessary for this infrastrucutre will be available at the right performance and price levels. This will make commercially viable an all-digital chain (capture, compression, transmission, reception decompression, hearing, and viewing). Unfortunately, the digital images received today must be translated into analog signals for viewing on today's televisions. Digital video is the final link in the all-digital infrastructure and DLP technoogy provides that link. DLP technology is an enabler for digital, high-resolution, color projection displays that have high contrast, are bright, seamless, and have the accuracy of color and grayscale that can be achieved only by digital control. This paper contains an introduction to DMD and DLP technology, including the historical context from which to view their developemnt. The architecture, projection operation, and fabrication are presented. Finally, the paper includes an update about current DMD business opportunities in projection displays and hardcopy.

  18. Silicon thin-film transistor backplanes on flexible substrates

    NASA Astrophysics Data System (ADS)

    Kattamis, Alexis Z.

    Flexible large area electronics, especially for displays, is a rapidly growing field. Since hydrogenated amorphous silicon thin-film transistors (a-Si:H TFTs) have become the industry standard for liquid crystal displays, it makes sense that they be used in any transition from glass substrates to flexible substrates. The goal of this thesis work was to implement a-Si:H backplane technology on stainless steel and clear plastic substrates, with minimal recipe changes to ensure high device quality. When fabricating TFTs on flexible substrates many new issues arise, from thin-film fracture to overlay alignment errors. Our approach was to maintain elevated deposition temperatures (˜300°C) and engineer methods to minimize these problems, rather than reducing deposition temperatures. The resulting TFTs exhibit more stable operation than their low temperature counterparts and are therefore similar to the TFTs produced on glass. Two display projects using a-Si:H TFTs will be discussed in detail. They are an active-matrix organic light emitting display (AMOLED) on stainless steel and an active-matrix electrophoretic display (AMEPD) on clear plastic, with TFTs deposited at 250°C-280°C. Achieving quality a-Si:H TFTs on these substrates required addressing a host of technical challenges, including surface roughness and feature misalignment. Nanocrystalline silicon (nc-Si) was also implemented on a clear plastic substrate as a possible alternative to a-Si:H. nc-Si:H TFTs can be deposited using the same techniques as a-Si:H but yield carrier mobilities one order of magnitude greater. Their large mobilities could enable high resolution OLED displays and system-on-panel electronics.

  19. High-Resolution Mg/Ca Ratios in a Coralline Red Alga as a Proxy for Bering Sea Temperature Variations and Teleconnections

    NASA Astrophysics Data System (ADS)

    Halfar, J.; Steffen, H.; Kronz, A.; Steneck, R. S.; Adey, W.; Lebednik, P. A.

    2009-05-01

    We present the first continuous high-resolution record of Mg/Ca variations within an encrusting coralline red alga of the species Clathromorphum nereostratum from Amchitka Island, Aleutian Islands. Mg/Ca ratios of individual growth increments were analyzed by measuring a single point electron microprobe transect yielding a resolution of 15 samples/year on average, generating a continuous record from 1830 to 1967 of algal Mg/Ca variations. Results show that Mg/Ca ratios in the high-Mg calcite skeleton display pronounced annual cyclicity and archive late spring to late fall sea surface temperature (SST) corresponding to the main season of algal growth. Mg/Ca values correlate well to local SST (ERSSTJun-Nov, 1902-1967; r = 0.73 for 5-year mean), as well as to an air temperature record from the same region. Our data correlate well to a shorter Mg/Ca record from a second site, corroborating the ability of the alga to reliably record regional environmental signals. In addition, Mg/Ca ratios relate well to a 29-year stable oxygen isotope time series measured on the same sample, which provides additional support for the use of Mg as a paleotemperature proxy in coralline red algae, that is, unlike stable oxygen isotopes, not influenced by salinity fluctuations. High spatial correlation to large-scale SST variability in the North Pacific is observed, with patterns of strongest correlation following the direction of major oceanographic features (i.e., the signature of the Alaska Current and the Alaskan Stream), which play a key role in the exchange of water masses between the North Pacific and the Bering Sea through Aleutian Island passages. The time series further displays significant teleconnections with the signature of the Pacific Decadal Oscillation in the northeast Pacific and the Atlantic Multidecadal Oscillation.

  20. The usefulness of the proximate status indication as represented by symbol fill on cockpit displays of traffic information

    DOT National Transportation Integrated Search

    2013-06-30

    Traffic Alert and Collision Avoidance Systems (TCAS) displays depict traffic advisories, resolution advisories, and information on other aircraft. Symbols for other aircraft include the proximate status indication where the symbols of proximate...

  1. Design of an off-axis visual display based on a free-form projection screen to realize stereo vision

    NASA Astrophysics Data System (ADS)

    Zhao, Yuanming; Cui, Qingfeng; Piao, Mingxu; Zhao, Lidong

    2017-10-01

    A free-form projection screen is designed for an off-axis visual display, which shows great potential in applications such as flight training for providing both accommodation and convergence cues for pilots. The method based on point cloud is proposed for the design of the free-form surface, and the design of the point cloud is controlled by a program written in the macro-language. In the visual display based on the free-form projection screen, when the error of the screen along Z-axis is 1 mm, the error of visual distance at each filed is less than 1%. And the resolution of the design for full field is better than 1‧, which meet the requirement of resolution for human eyes.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew, E-mail: andrew.karellas@umassmed.edu

    Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixelmore » pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.« less

  3. (abstract) Venus Gravity Field

    NASA Technical Reports Server (NTRS)

    Konopliv, A. S.; Sjogren, W. L.

    1995-01-01

    A global gravity field model of Venus to degree and order 75 (5772 spherical harmonic coefficients) has been estimated from Doppler radio tracking of the orbiting spacecraft Pioneer Venus Orbiter (1979-1992) and Magellan (1990-1994). After the successful aerobraking of Magellan, a near circular polar orbit was attained and relatively uniform gravity field resolution (approximately 200 km) was obtained with formal uncertainties of a few milligals. Detailed gravity for several highland features are displayed as gravity contours overlaying colored topography. The positive correlation of typography with gravity is very high being unlike that of the Earth, Moon, and Mars. The amplitudes are Earth-like, but have significantly different gravity-topography ratios for different features. Global gravity, geoid, and isostatic anomaly maps as well as the admittance function are displayed.

  4. Developing Remote Sensing Capabilities for Meter-Scale Sea Ice Properties

    DTIC Science & Technology

    2013-09-30

    such as MODIS . APPROACH 1. Task and acquire high resolution panchromatic and multispectral optical (e.g. Quickbird, Worldview, National Assets...does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00-2013 4...cloud cover , an excessive percentage of the imagery acquired over drifting sites was cloud covered , and the vendor did not delay acquisitions or

  5. Fully Solution-Processed Tandem White Quantum-Dot Light-Emitting Diode with an External Quantum Efficiency Exceeding 25.

    PubMed

    Jiang, Congbiao; Zou, Jianhua; Liu, Yu; Song, Chen; He, Zhiwei; Zhong, Zhenji; Wang, Jian; Yip, Hin-Lap; Peng, Junbiao; Cao, Yong

    2018-06-15

    Solution-processed electroluminescent tandem white quantum-dot light-emitting diodes (TWQLEDs) have the advantages of being low-cost and high-efficiency and having a wide color gamut combined with color filters, making this a promising backlight technology for high-resolution displays. However, TWQLEDs are rarely reported due to the challenge of designing device structures and the deterioration of film morphology with component layers that can be deposited from solutions. Here, we report an interconnecting layer with the optical, electrical, and mechanical properties required for fully solution-processed TWQLED. The optimized TWQLEDs exhibit a state-of-the-art current efficiency as high as 60.4 cd/A and an extremely high external quantum efficiency of 27.3% at a luminance of 100 000 cd/m 2 . A high color gamut of 124% NTSC 1931 standard can be achieved when combined with commercial color filters. These results represent the highest performance for solution-processed WQLEDs, unlocking the great application potential of TWQLEDs as backlights for new-generation displays.

  6. The development and validation of command schedules for SeaWiFS

    NASA Astrophysics Data System (ADS)

    Woodward, Robert H.; Gregg, Watson W.; Patt, Frederick S.

    1994-11-01

    An automated method for developing and assessing spacecraft and instrument command schedules is presented for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) project. SeaWiFS is to be carried on the polar-orbiting SeaStar satellite in 1995. The primary goal of the SeaWiFS mission is to provide global ocean chlorophyll concentrations every four days by employing onboard recorders and a twice-a-day data downlink schedule. Global Area Coverage (GAC) data with about 4.5 km resolution will be used to produce the global coverage. Higher resolution (1.1 km resolution) Local Area Coverage (LAC) data will also be recorded to calibrate the sensor. In addition, LAC will be continuously transmitted from the satellite and received by High Resolution Picture Transmission (HRPT) stations. The methods used to generate commands for SeaWiFS employ numerous hierarchical checks as a means of maximizing coverage of the Earth's surface and fulfilling the LAC data requirements. The software code is modularized and written in Fortran with constructs to mirror the pre-defined mission rules. The overall method is specifically developed for low orbit Earth-observing satellites with finite onboard recording capabilities and regularly scheduled data downlinks. Two software packages using the Interactive Data Language (IDL) for graphically displaying and verifying the resultant command decisions are presented. Displays can be generated which show portions of the Earth viewed by the sensor and spacecraft sub-orbital locations during onboard calibration activities. An IDL-based interactive method of selecting and testing LAC targets and calibration activities for command generation is also discussed.

  7. Improved-resolution real-time skin-dose mapping for interventional fluoroscopic procedures

    NASA Astrophysics Data System (ADS)

    Rana, Vijay K.; Rudin, Stephen; Bednarek, Daniel R.

    2014-03-01

    We have developed a dose-tracking system (DTS) that provides a real-time display of the skin-dose distribution on a 3D patient graphic during fluoroscopic procedures. Radiation dose to individual points on the skin is calculated using exposure and geometry parameters from the digital bus on a Toshiba C-arm unit. To accurately define the distribution of dose, it is necessary to use a high-resolution patient graphic consisting of a large number of elements. In the original DTS version, the patient graphics were obtained from a library of population body scans which consisted of larger-sized triangular elements resulting in poor congruence between the graphic points and the x-ray beam boundary. To improve the resolution without impacting real-time performance, the number of calculations must be reduced and so we created software-designed human models and modified the DTS to read the graphic as a list of vertices of the triangular elements such that common vertices of adjacent triangles are listed once. Dose is calculated for each vertex point once instead of the number of times that a given vertex appears in multiple triangles. By reformatting the graphic file, we were able to subdivide the triangular elements by a factor of 64 times with an increase in the file size of only 1.3 times. This allows a much greater number of smaller triangular elements and improves resolution of the patient graphic without compromising the real-time performance of the DTS and also gives a smoother graphic display for better visualization of the dose distribution.

  8. An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

    NASA Technical Reports Server (NTRS)

    Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.

    2015-01-01

    A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the development of DAA display performance standards, as well as the need for future research are discussed.

  9. Thin glass substrates for mobile applications

    NASA Astrophysics Data System (ADS)

    Mauch, Reiner H.; Wegener, Holger; Kruse, Anke; Hildebrand, Norbert

    2000-10-01

    Flat panel displays play an important role as the visual interface for today's electronic devices (Notebook computers, PDA's, pagers, mobile phones, etc.). Liquid Crystal Display's are dominating the market. While for higher resolution displays active matrix displays like Thin Film Transistor LCD's are used, portable devices are mainly using Super Twisted Nematic (STN) displays. Based on the application, STN displays for mobile applications require thinner glass substrates with improved surface quality at a lower cost. The requirements and trends for STN glass substrates are identified and discussed. Different glass manufacturing processes are used today for the manufacture of these substrates. Advantages and disadvantages of the different glass substrate types are presented and discussed.

  10. Vroom: designing an augmented environment for remote collaboration in digital cinema production

    NASA Astrophysics Data System (ADS)

    Margolis, Todd; Cornish, Tracy

    2013-03-01

    As media technologies become increasingly affordable, compact and inherently networked, new generations of telecollaborative platforms continue to arise which integrate these new affordances. Virtual reality has been primarily concerned with creating simulations of environments that can transport participants to real or imagined spaces that replace the "real world". Meanwhile Augmented Reality systems have evolved to interleave objects from Virtual Reality environments into the physical landscape. Perhaps now there is a new class of systems that reverse this precept to enhance dynamic media landscapes and immersive physical display environments to enable intuitive data exploration through collaboration. Vroom (Virtual Room) is a next-generation reconfigurable tiled display environment in development at the California Institute for Telecommunications and Information Technology (Calit2) at the University of California, San Diego. Vroom enables freely scalable digital collaboratories, connecting distributed, high-resolution visualization resources for collaborative work in the sciences, engineering and the arts. Vroom transforms a physical space into an immersive media environment with large format interactive display surfaces, video teleconferencing and spatialized audio built on a highspeed optical network backbone. Vroom enables group collaboration for local and remote participants to share knowledge and experiences. Possible applications include: remote learning, command and control, storyboarding, post-production editorial review, high resolution video playback, 3D visualization, screencasting and image, video and multimedia file sharing. To support these various scenarios, Vroom features support for multiple user interfaces (optical tracking, touch UI, gesture interface, etc.), support for directional and spatialized audio, giga-pixel image interactivity, 4K video streaming, 3D visualization and telematic production. This paper explains the design process that has been utilized to make Vroom an accessible and intuitive immersive environment for remote collaboration specifically for digital cinema production.

  11. CLICK: The new USGS center for LIDAR information coordination and knowledge

    USGS Publications Warehouse

    Stoker, Jason M.; Greenlee, Susan K.; Gesch, Dean B.; Menig, Jordan C.

    2006-01-01

    Elevation data is rapidly becoming an important tool for the visualization and analysis of geographic information. The creation and display of three-dimensional models representing bare earth, vegetation, and structures have become major requirements for geographic research in the past few years. Light Detection and Ranging (lidar) has been increasingly accepted as an effective and accurate technology for acquiring high-resolution elevation data for bare earth, vegetation, and structures. Lidar is an active remote sensing system that records the distance, or range, of a laser fi red from an airborne or space borne platform such as an airplane, helicopter or satellite to objects or features on the Earth’s surface. By converting lidar data into bare ground topography and vegetation or structural morphologic information, extremely accurate, high-resolution elevation models can be derived to visualize and quantitatively represent scenes in three dimensions. In addition to high-resolution digital elevation models (Evans et al., 2001), other lidar-derived products include quantitative estimates of vegetative features such as canopy height, canopy closure, and biomass (Lefsky et al., 2002), and models of urban areas such as building footprints and three-dimensional city models (Maas, 2001).

  12. Displaying Data As Movies

    NASA Technical Reports Server (NTRS)

    Moore, Judith G.

    1992-01-01

    NMSB Movie computer program displays large sets of data (more than million individual values). Presentation dynamic, rapidly displaying sequential image "frames" in main "movie" window. Any sequence of two-dimensional sets of data scaled between 0 and 255 (1-byte resolution) displayed as movie. Time- or slice-wise progression of data illustrated. Originally written to present data from three-dimensional ultrasonic scans of damaged aerospace composite materials, illustrates data acquired by thermal-analysis systems measuring rates of heating and cooling of various materials. Developed on Macintosh IIx computer with 8-bit color display adapter and 8 megabytes of memory using Symantec Corporation's Think C, version 4.0.

  13. Combined illumination cylindrical millimeter-wave imaging technique for concealed weapon detection

    NASA Astrophysics Data System (ADS)

    Sheen, David M.; McMakin, Douglas L.; Hall, Thomas E.

    2000-07-01

    A novel millimeter-wave imaging technique has been developed for personnel surveillance applications, including the detection of concealed weapons, explosives, drugs, and other contraband material. Millimeter-waves are high-frequency radio waves in the frequency band of 30 - 300 GHz, and pose no health threat to humans at moderate power levels. These waves readily penetrate common clothing materials, and are reflected by the human body and by concealed items. The combined illumination cylindrical imaging concept consists of a vertical, high-resolution, millimeter-wave array of antennas which is scanned in a cylindrical manner about the person under surveillance. Using a computer, the data from this scan is mathematically reconstructed into a series of focused 3D images of the person. After reconstruction, the images are combined into a single high-resolution 3D image of the person under surveillance. This combined image is then rendered using 3D computer graphics techniques. The combined cylindrical illumination is critical as it allows the display of information from all angles. This is necessary because millimeter-waves do not penetrate the body. Ultimately, the images displayed to the operate will be icon-based to protect the privacy of the person being screened. Novel aspects of this technique include the cylindrical scanning concept and the image reconstruction algorithm, which was developed specifically for this imaging system. An engineering prototype based on this cylindrical imaging technique has been fabricated and tested. This work has been sponsored by the Federal Aviation Administration.

  14. Mechanisms of time-based figure-ground segregation.

    PubMed

    Kandil, Farid I; Fahle, Manfred

    2003-11-01

    Figure-ground segregation can rely on purely temporal information, that is, on short temporal delays between positional changes of elements in figure and ground (Kandil, F.I. & Fahle, M. (2001) Eur. J. Neurosci., 13, 2004-2008). Here, we investigate the underlying mechanisms by measuring temporal segregation thresholds for various kinds of motion cues. Segregation can rely on monocular first-order motion (based on luminance modulation) and second-order motion cues (contrast modulation) with a high temporal resolution of approximately 20 ms. The mechanism can also use isoluminant motion with a reduced temporal resolution of 60 ms. Figure-ground segregation can be achieved even at presentation frequencies too high for human subjects to inspect successive frames individually. In contrast, when stimuli are presented dichoptically, i.e. separately to both eyes, subjects are unable to perceive any segregation, irrespective of temporal frequency. We propose that segregation in these displays is detected by a mechanism consisting of at least two stages. On the first level, standard motion or flicker detectors signal local positional changes (flips). On the second level, a segregation mechanism combines the local activities of the low-level detectors with high temporal precision. Our findings suggest that the segregation mechanism can rely on monocular detectors but not on binocular mechanisms. Moreover, the results oppose the idea that segregation in these displays is achieved by motion detectors of a higher order (motion-from-motion), but favour mechanisms sensitive to short temporal delays even without activation of higher-order motion detectors.

  15. Resolution of donor non-alcoholic fatty liver disease following liver transplantation.

    PubMed

    Posner, Andrew D; Sultan, Samuel T; Zaghloul, Norann A; Twaddell, William S; Bruno, David A; Hanish, Steven I; Hutson, William R; Hebert, Laci; Barth, Rolf N; LaMattina, John C

    2017-09-01

    Transplant surgeons conventionally select against livers displaying high degrees (>30%) of macrosteatosis (MaS), out of concern for primary non-function or severe graft dysfunction. As such, there is relatively limited experience with such livers, and the natural history remains incompletely characterized. We present our experience of transplanted livers with high degrees of MaS and microsteatosis (MiS), with a focus on the histopathologic and clinical outcomes. Twenty-nine cases were identified with liver biopsies available from both the donor and the corresponding liver transplant recipient. Donor liver biopsies displayed either MaS or MiS ≥15%, while all recipients received postoperative liver biopsies for cause. The mean donor MaS and MiS were 15.6% (range 0%-60%) and 41.3% (7.5%-97.5%), respectively. MaS decreased significantly from donor (M=15.6%) to recipient postoperative biopsies (M=0.86%), P<.001. Similarly, MiS decreased significantly from donor biopsies (M=41.3%) to recipient postoperative biopsies (M=1.8%), P<.001. At a median of 68 days postoperatively (range 4-384), full resolution of MaS and MiS was observed in 27 of 29 recipients. High degrees of MaS and MiS in donor livers resolve in recipients following liver transplantation. Further insight into the mechanisms responsible for treating fatty liver diseases could translate into therapeutic targets. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. High-Resolution Graphene Films for Electrochemical Sensing via Inkjet Maskless Lithography.

    PubMed

    Hondred, John A; Stromberg, Loreen R; Mosher, Curtis L; Claussen, Jonathan C

    2017-10-24

    Solution-phase printing of nanomaterial-based graphene inks are rapidly gaining interest for fabrication of flexible electronics. However, scalable manufacturing techniques for high-resolution printed graphene circuits are still lacking. Here, we report a patterning technique [i.e., inkjet maskless lithography (IML)] to form high-resolution, flexible, graphene films (line widths down to 20 μm) that significantly exceed the current inkjet printing resolution of graphene (line widths ∼60 μm). IML uses an inkjet printed polymer lacquer as a sacrificial pattern, viscous spin-coated graphene, and a subsequent graphene lift-off to pattern films without the need for prefabricated stencils, templates, or cleanroom technology (e.g., photolithography). Laser annealing is employed to increase conductivity on thermally sensitive, flexible substrates [polyethylene terephthalate (PET)]. Laser annealing and subsequent platinum nanoparticle deposition substantially increases the electroactive nature of graphene as illustrated by electrochemical hydrogen peroxide (H 2 O 2 ) sensing [rapid response (5 s), broad linear sensing range (0.1-550 μm), high sensitivity (0.21 μM/μA), and low detection limit (0.21 μM)]. Moreover, high-resolution, complex graphene circuits [i.e., interdigitated electrodes (IDE) with varying finger width and spacing] were created with IML and characterized via potassium chloride (KCl) electrochemical impedance spectroscopy (EIS). Results indicated that sensitivity directly correlates to electrode feature size as the IDE with the smallest finger width and spacing (50 and 50 μm) displayed the largest response to changes in KCl concentration (∼21 kΩ). These results indicate that the developed IML patterning technique is well-suited for rapid, solution-phase graphene film prototyping on flexible substrates for numerous applications including electrochemical sensing.

  17. Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

    PubMed

    Mc Laughlin, Patrick; Neill, Siobhan O; Fanning, Noel; Mc Garrigle, Anne Marie; Connor, Owen J O; Wyse, Gerry; Maher, Michael M

    2012-04-01

    Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.

  18. Analysis of the diffraction effects for a multi-view autostereoscopic three-dimensional display system based on shutter parallax barriers with full resolution

    NASA Astrophysics Data System (ADS)

    Meng, Yang; Yu, Zhongyuan; Jia, Fangda; Zhang, Chunyu; Wang, Ye; Liu, Yumin; Ye, Han; Chen, Laurence Lujun

    2017-10-01

    A multi-view autostereoscopic three-dimensional (3D) system is built by using a 2D display screen and a customized parallax-barrier shutter (PBS) screen. The shutter screen is controlled dynamically by address driving matrix circuit and it is placed in front of the display screen at a certain location. The system could achieve densest viewpoints due to its specially optical and geometric design which is based on concept of "eye space". The resolution of 3D imaging is not reduced compared to 2D mode by using limited time division multiplexing technology. The diffraction effects may play an important role in 3D display imaging quality, especially when applied to small screen, such as iPhone screen etc. For small screen, diffraction effects may contribute crosstalk between binocular views, image brightness uniformity etc. Therefore, diffraction effects are analyzed and considered in a one-dimensional shutter screen model of the 3D display, in which the numerical simulation of light from display pixels on display screen through parallax barrier slits to each viewing zone in eye space, is performed. The simulation results provide guidance for criteria screen size over which the impact of diffraction effects are ignorable, and below which diffraction effects must be taken into account. Finally, the simulation results are compared to the corresponding experimental measurements and observation with discussion.

  19. High definition TV projection via single crystal faceplate technology

    NASA Astrophysics Data System (ADS)

    Kindl, H. J.; St. John, Thomas

    1993-03-01

    Single crystal phosphor faceplates are epitaxial phosphors grown on crystalline substrates with the advantages of high light output, resolution, and extended operational life. Single crystal phosphor faceplate industrial technology in the United States is capable of providing a faceplate appropriate to the projection industry of up to four (4) inches in diameter. Projection systems incorporating cathode ray tubes utilizing single crystal phosphor faceplates will produce 1500 lumens of white light with 1000 lines of resolution, non-interlaced. This 1500 lumen projection system will meet all of the currently specified luminance and resolution requirements of Visual Display systems for flight simulators. Significant logistic advantages accrue from the introduction of single crystal phosphor faceplate CRT's. Specifically, the full performance life of a CRT is expected to increase by a factor of five (5); ie, from 2000 to 10,000 hours of operation. There will be attendant reductions in maintenance time, spare CRT requirements, system down time, etc. The increased brightness of the projection system will allow use of lower gain, lower cost simulator screen material. Further, picture performance characteristics will be more balanced across the full simulator.

  20. Military display performance parameters

    NASA Astrophysics Data System (ADS)

    Desjardins, Daniel D.; Meyer, Frederick

    2012-06-01

    The military display market is analyzed in terms of four of its segments: avionics, vetronics, dismounted soldier, and command and control. Requirements are summarized for a number of technology-driving parameters, to include luminance, night vision imaging system compatibility, gray levels, resolution, dimming range, viewing angle, video capability, altitude, temperature, shock and vibration, etc., for direct-view and virtual-view displays in cockpits and crew stations. Technical specifications are discussed for selected programs.

  1. Extremely Vivid, Highly Transparent, and Ultrathin Quantum Dot Light-Emitting Diodes.

    PubMed

    Choi, Moon Kee; Yang, Jiwoong; Kim, Dong Chan; Dai, Zhaohe; Kim, Junhee; Seung, Hyojin; Kale, Vinayak S; Sung, Sae Jin; Park, Chong Rae; Lu, Nanshu; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2018-01-01

    Displaying information on transparent screens offers new opportunities in next-generation electronics, such as augmented reality devices, smart surgical glasses, and smart windows. Outstanding luminance and transparency are essential for such "see-through" displays to show vivid images over clear background view. Here transparent quantum dot light-emitting diodes (Tr-QLEDs) are reported with high brightness (bottom: ≈43 000 cd m -2 , top: ≈30 000 cd m -2 , total: ≈73 000 cd m -2 at 9 V), excellent transmittance (90% at 550 nm, 84% over visible range), and an ultrathin form factor (≈2.7 µm thickness). These superb characteristics are accomplished by novel electron transport layers (ETLs) and engineered quantum dots (QDs). The ETLs, ZnO nanoparticle assemblies with ultrathin alumina overlayers, dramatically enhance durability of active layers, and balance electron/hole injection into QDs, which prevents nonradiative recombination processes. In addition, the QD structure is further optimized to fully exploit the device architecture. The ultrathin nature of Tr-QLEDs allows their conformal integration on various shaped objects. Finally, the high resolution patterning of red, green, and blue Tr-QLEDs (513 pixels in. -1 ) shows the potential of the full-color transparent display. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Avionic Pictorial Tunnel-/Pathway-/Highway-In-The-Sky Workshops

    NASA Technical Reports Server (NTRS)

    Parrish, Russell V. (Compiler)

    2003-01-01

    In 1994-96, Langley Research Center held a series of interactive workshops investigating highway-in-the-sky concepts, which enable precise flight path control. These workshops brought together government and industry display designers and pilots to discuss and fly various concepts in an iterative manner. The primary emphasis of the first workshops was the utility and usability of pathways and the pros and cons of various features available. The final workshops were focused on the specific applications to the eXternal Visibility System (XVS) of the NASA High-speed Research Program, which was concerned with replacement of the forward windows in a High-speed Civil Transport with electronic displays and high resolution video cameras to enable a "No-Droop" configuration. The primary concerns in the XVS application were the prevention of display clutter and obscuration of hazards, as the camera image was the primary means of traffic separation in clear visibility conditions. These concerns were not so prominent in the first workshops, which assumed a Synthetic Vision System application in which hazard locations are known and obscuration is handled easily. The resulting consensus concept has been used since in simulation and flight test activities of many Government programs. and other concepts have been influenced by the workshop discussions.

  3. Evaluation of the use of a tablet computer with a high-resolution display for interpreting emergency CT scans.

    PubMed

    Tewes, S; Rodt, T; Marquardt, S; Evangelidou, E; Wacker, F K; von Falck, C

    2013-11-01

    Evaluation of the potential usability of an iPad 3 with a high-resolution display in CT emergency diagnosis compared to a 3 D PACS workstation. 3 readers used a 5-point Likert scale to evaluate 40 CCT scans and 40 CTPA scans to determine the detectability of early signs of infarction in CCT or segmental and subsegmental pulmonary embolisms in CT angiography of the pulmonary arteries (CTPA) on the iPad 3 (Apple Inc., USA) using an application for image viewing (Visage Ease, Visage Imaging GmbH, Berlin) and on a 3 D PACS workstation (Visage 7.1, Visage Imaging, Berlin) using a certified monitor for image viewing. The results were compared using the Wilcoxon rank sum test, Spearman's correlation coefficient, and a kappa statistic. There was no significant difference in the median evaluations for the readings of both the CCT scans and the CTPA scans on the iPad 3 and on the workstation (p > 0.05) for all three readers. The mean Spearman's correlation coefficient for CCT and CTPA was 0.46 (± 0.2) and 0.69 (± 0.16), respectively, for the comparison iPad/PACS, 0.41 (± 0.16) and 0.68 (± 0.06), respectively, for the interobserver agreement on the iPad, and 0.35 (± 0.05) and 0.68 (± 0.10), respectively, for the interobserver agreement on the PACS. Mean kappa values for CCT of 0.52 (± 0.17) for the comparison iPad/PACS and 0.33 (± 0.16) and 0.32 (± 0.16), respectively, for the interobserver agreement on the iPad and the PACS were achieved. For CTPA average kappa values of 0.67 (± 0.19) were calculated for the comparison iPad/PACS and 0.69 (± 0.08) and 0.60 (± 0.14), respectively, for the interobserver concordance on the iPad 3 and the PACS. All differences were not statistically significant (p > 0.05). The variability of the interpretation of typical emergency scans on an iPad 3 with a high-resolution display and on a 3 D PACS workstation does not differ from the interobserver variability. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Detailed sensory memory, sloppy working memory.

    PubMed

    Sligte, Ilja G; Vandenbroucke, Annelinde R E; Scholte, H Steven; Lamme, Victor A F

    2010-01-01

    Visual short-term memory (VSTM) enables us to actively maintain information in mind for a brief period of time after stimulus disappearance. According to recent studies, VSTM consists of three stages - iconic memory, fragile VSTM, and visual working memory - with increasingly stricter capacity limits and progressively longer lifetimes. Still, the resolution (or amount of visual detail) of each VSTM stage has remained unexplored and we test this in the present study. We presented people with a change detection task that measures the capacity of all three forms of VSTM, and we added an identification display after each change trial that required people to identify the "pre-change" object. Accurate change detection plus pre-change identification requires subjects to have a high-resolution representation of the "pre-change" object, whereas change detection or identification only can be based on the hunch that something has changed, without exactly knowing what was presented before. We observed that people maintained 6.1 objects in iconic memory, 4.6 objects in fragile VSTM, and 2.1 objects in visual working memory. Moreover, when people detected the change, they could also identify the pre-change object on 88% of the iconic memory trials, on 71% of the fragile VSTM trials and merely on 53% of the visual working memory trials. This suggests that people maintain many high-resolution representations in iconic memory and fragile VSTM, but only one high-resolution object representation in visual working memory.

  5. High resolution synchrotron X-radiation diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

    NASA Technical Reports Server (NTRS)

    Steiner, Bruce; Dobbyn, Ronald C.; Black, David; Burdette, Harold; Kuriyama, Masao; Fripp, Archibald; Simchik, Richard

    1991-01-01

    Irregularities in three crystals grown in space and in four terrestrial crystals grown under otherwise comparable conditions have been observed in high resolution diffraction imaging. The images provide important new clues to the nature and origins of irregularities in each crystal. For two of the materials, mercuric iodide and lead tin telluride, more than one phase (an array of non-diffracting inclusions) was observed in terrestrial samples; but the formation of these multiple phases appears to have been suppressed in directly comparable crystals grown in microgravity. The terrestrial seed crystal of triglycine sulfate displayed an unexpected layered structure, which propagated during directly comparable space growth. Terrestrial Bridgman regrowth of gallium arsenide revealed a mesoscopic structure substantially different from that of the original Czochralski material. A directly comparable crystal is to be grown shortly in space.

  6. Investigating equality: The Rényi spectrum

    NASA Astrophysics Data System (ADS)

    Eliazar, Iddo

    2017-09-01

    An equality index is a score quantifying the socioeconomic egalitarianism of the distribution of wealth in human societies; the score takes values in the unit interval, with the unit upper bound characterizing purely communist societies. In this paper we explore the Rényi spectrum, a continuum of equality indices that: (i) is based on the moments of the societies' distributions of wealth; (ii) unifies various measures of socioeconomic inequality, including the Theil and Atkinson indices; (iii) displays a collection of amicable analytic properties; (iv) admits multiple Rényi-divergence representations; and (v) provides a high-resolution gauging of egalitarianism that is way beyond what can be offered by the common-practice measures of socioeconomic inequality, the Gini and Pietra indices. At large, the Rényi spectrum is applicable in the context of any distribution of non-negative sizes with a positive mean-yielding a high-resolution gauging of the distribution's inherent statistical heterogeneity.

  7. Volumetric visualization of multiple-return LIDAR data: Using voxels

    USGS Publications Warehouse

    Stoker, Jason M.

    2009-01-01

    Elevation data are an important component in the visualization and analysis of geographic information. The creation and display of 3D models representing bare earth, vegetation, and surface structures have become a major focus of light detection and ranging (lidar) remote sensing research in the past few years. Lidar is an active sensor that records the distance, or range, of a laser usually fi red from an airplane, helicopter, or satellite. By converting the millions of 3D lidar returns from a system into bare ground, vegetation, or structural elevation information, extremely accurate, high-resolution elevation models can be derived and produced to visualize and quantify scenes in three dimensions. These data can be used to produce high-resolution bare-earth digital elevation models; quantitative estimates of vegetative features such as canopy height, canopy closure, and biomass; and models of urban areas such as building footprints and 3D city models.

  8. Low-temperature THz time domain waveguide spectrometer with butt-coupled emitter and detector crystal.

    PubMed

    Qiao, W; Stephan, D; Hasselbeck, M; Liang, Q; Dekorsy, T

    2012-08-27

    A compact high-resolution THz time-domain waveguide spectrometer that is operated inside a cryostat is demonstrated. A THz photo-Dember emitter and a ZnTe electro-optic detection crystal are directly attached to a parallel copper-plate waveguide. This allows the THz beam to be excited and detected entirely inside the cryostat, obviating the need for THz-transparent windows or external THz mirrors. Since no external bias for the emitter is required, no electric feed-through into the cryostat is necessary. Using asynchronous optical sampling, high resolution THz spectra are obtained in the frequency range from 0.2 to 2.0 THz. The THz emission from the photo-Dember emitter and the absorption spectrum of 1,2-dicyanobenzene film are measured as a function of temperature. An absorption peak around 750 GHz of 1,2-dicyanobenzene displays a blue shift with increasing temperature.

  9. High-resolution magic angle spinning 1H-NMR spectroscopy studies on the renal biochemistry in the bank vole (Clethrionomys glareolus) and the effects of arsenic (As3+) toxicity.

    PubMed

    Griffin, J L; Walker, L; Shore, R F; Nicholson, J K

    2001-06-01

    1. High-resolution magic angle spinning (MAS) 1H-NMR spectroscopy was used to study renal metabolism and the toxicity of As3+, a common environmental contaminant, in the bank vole (Clethrionomys glareolus), a wild species of rodent. 2. Following a 14-day exposure to an environmentally relevant dose of As2O3 (28 mg kg(-1) feed), voles displayed tissue damage at autopsy. MAS 1H spectra indicated abnormal lipid profiles in these samples. 3. Tissue necrosis was also evident from measurements of the apparent diffusion coefficient of water in the intact tissue using MAS 1H diffusion-weighted spectroscopy, its first application to toxicology. 4. Comparison of renal tissue from the wood mouse (Apodemus sylvaticus) exposed to identical exposure levels of As3+ suggested that the bank vole is particularly vulnerable to As3+ toxicity.

  10. Computational considerations for collecting and using data in the equidistant cylindrical map projection and the bounds of sampling geographic data at progressively higher resolution

    USGS Publications Warehouse

    Foley, Kevin M.

    2011-01-01

    The Equidistant Cylindrical Map projection is popular with digital modelers and others for storing and processing worldwide data sets because of the simple association of latitude and longitude to cell values or pixels in the resulting grid. This projection does not accurately display area, and the diminished geographic area represented by cells at high latitudes is not often carefully considered. A simple mathematical analysis quantifies the discrepancy in area sampled by cells at different latitudes. The presence of this discrepancy indicates that the use of this projection can induce bias in data sets when both sampling and reporting data. It is demonstrated that as the resolution requirements of input data for models increase, the necessity of providing data to accurately describe smaller cells, particularly at high latitude, will be a challenge.

  11. High-resolution profiling of linear B-cell epitopes from mucin-associated surface proteins (MASPs) of Trypanosoma cruzi during human infections

    PubMed Central

    Durante, Ignacio M.; La Spina, Pablo E.; Carmona, Santiago J.; Agüero, Fernán

    2017-01-01

    Background The Trypanosoma cruzi genome bears a huge family of genes and pseudogenes coding for Mucin-Associated Surface Proteins (MASPs). MASP molecules display a ‘mosaic’ structure, with highly conserved flanking regions and a strikingly variable central and mature domain made up of different combinations of a large repertoire of short sequence motifs. MASP molecules are highly expressed in mammal-dwelling stages of T. cruzi and may be involved in parasite-host interactions and/or in diverting the immune response. Methods/Principle findings High-density microarrays composed of fully overlapped 15mer peptides spanning the entire sequences of 232 non-redundant MASPs (~25% of the total MASP content) were screened with chronic Chagasic sera. This strategy led to the identification of 86 antigenic motifs, each one likely representing a single linear B-cell epitope, which were mapped to 69 different MASPs. These motifs could be further grouped into 31 clusters of structurally- and likely antigenically-related sequences, and fully characterized. In contrast to previous reports, we show that MASP antigenic motifs are restricted to the central and mature region of MASP polypeptides, consistent with their intracellular processing. The antigenicity of these motifs displayed significant positive correlation with their genome dosage and their relative position within the MASP polypeptide. In addition, we verified the biased genetic co-occurrence of certain antigenic motifs within MASP polypeptides, compatible with proposed intra-family recombination events underlying the evolution of their coding genes. Sequences spanning 7 MASP antigenic motifs were further evaluated using distinct synthesis/display approaches and a large panel of serum samples. Overall, the serological recognition of MASP antigenic motifs exhibited a remarkable non normal distribution among the T. cruzi seropositive population, thus reducing their applicability in conventional serodiagnosis. As previously observed in in vitro and animal infection models, immune signatures supported the concurrent expression of several MASPs during human infection. Conclusions/Significance In spite of their conspicuous expression and potential roles in parasite biology, this study constitutes the first unbiased, high-resolution profiling of linear B-cell epitopes from T. cruzi MASPs during human infection. PMID:28961244

  12. Future directions in 3-dimensional imaging and neurosurgery: stereoscopy and autostereoscopy.

    PubMed

    Christopher, Lauren A; William, Albert; Cohen-Gadol, Aaron A

    2013-01-01

    Recent advances in 3-dimensional (3-D) stereoscopic imaging have enabled 3-D display technologies in the operating room. We find 2 beneficial applications for the inclusion of 3-D imaging in clinical practice. The first is the real-time 3-D display in the surgical theater, which is useful for the neurosurgeon and observers. In surgery, a 3-D display can include a cutting-edge mixed-mode graphic overlay for image-guided surgery. The second application is to improve the training of residents and observers in neurosurgical techniques. This article documents the requirements of both applications for a 3-D system in the operating room and for clinical neurosurgical training, followed by a discussion of the strengths and weaknesses of the current and emerging 3-D display technologies. An important comparison between a new autostereoscopic display without glasses and current stereo display with glasses improves our understanding of the best applications for 3-D in neurosurgery. Today's multiview autostereoscopic display has 3 major benefits: It does not require glasses for viewing; it allows multiple views; and it improves the workflow for image-guided surgery registration and overlay tasks because of its depth-rendering format and tools. Two current limitations of the autostereoscopic display are that resolution is reduced and depth can be perceived as too shallow in some cases. Higher-resolution displays will be available soon, and the algorithms for depth inference from stereo can be improved. The stereoscopic and autostereoscopic systems from microscope cameras to displays were compared by the use of recorded and live content from surgery. To the best of our knowledge, this is the first report of application of autostereoscopy in neurosurgery.

  13. Adaptive Beamforming Algorithms for High Resolution Microwave Imaging

    DTIC Science & Technology

    1991-04-01

    frequency- and phase -locked. With a system of radio camera size it must be assumed that oscillators will drift and, similarly, that electronic circuits in...propagation-induced phase errors an array as large as the one under discussion is likely to experience differ- ent weather conditions across it. The nominal...human optical system. Such a passing-scene display with human optical resolving power would be available to the air - man at night as well as during the

  14. Earth observations taken by the STS-59 crew

    NASA Image and Video Library

    1994-04-14

    STS059-306-034 (9-20 April 1994) --- The radiating transportation pattern of this 20th-Century urban plan is nicely displayed in this high-resolution photograph. Light-toned spots in the desert mark oil well sites; along the south edge of the scene, some dark residue remains from the fires set during the recent Gulf War. Blown sand has nearly hidden the soot and thick oil that were deposited on the surface. Nikon photograph, 300mm lens.

  15. High-resolution telomere fluorescence in situ hybridization reveals intriguing anomalies in germ cell tumors.

    PubMed

    Shekhani, Mohammed Talha; Barber, John R; Bezerra, Stephania M; Heaphy, Christopher M; Gonzalez Roibon, Nilda Diana; Taheri, Diana; Reis, Leonardo O; Guner, Gunes; Joshu, Corinne E; Netto, George J; Meeker, Alan K

    2016-08-01

    Testicular germ cell tumor (TGCT) is the most common malignancy of young men. Most patients are completely cured, which distinguishes these from most other malignancies. Orchiectomy specimens (n=76) were evaluated using high-resolution (single-cell discriminative) telomere-specific fluorescence in situ hybridization (FISH) with simultaneous Oct4 immunofluorescence to describe telomere length phenotype in TGCT neoplastic cells. For the first time, the TGCT precursor lesion, germ cell neoplasia in situ (GCNIS) is also evaluated in depth. The intensity of the signals from cancerous cells was compared to the same patient's reference cells-namely, healthy germ cells (defined as "medium" length) and interstitial/somatic cells (defined as "short" telomere length). We observed short telomeres in most GCNIS and pure seminomas (P=.006 and P=.0005, respectively). In contrast, nonseminomas displayed longer telomeres. Lesion-specific telomere lengths were documented in mixed tumor cases. Embryonal carcinoma (EC) demonstrated the longest telomeres. A fraction of EC displays the telomerase-independent alternative lengthening of telomeres (ALT) phenotype (24% of cases). Loss of ATRX or DAXX nuclear expression was strongly associated with ALT; however, nuclear expression of both proteins was retained in half of ALT-positive ECs. The particular distribution of telomere lengths among TGCT and GCNIS precursors implicate telomeres anomalies in pathogenesis. These results may advise management decisions as well. Copyright © 2016. Published by Elsevier Inc.

  16. Recent progress in high performance and reliable n-type transition metal oxide-based thin film transistors

    NASA Astrophysics Data System (ADS)

    Kwon, Jang Yeon; Kyeong Jeong, Jae

    2015-02-01

    This review gives an overview of the recent progress in vacuum-based n-type transition metal oxide (TMO) thin film transistors (TFTs). Several excellent review papers regarding metal oxide TFTs in terms of fundamental electron structure, device process and reliability have been published. In particular, the required field-effect mobility of TMO TFTs has been increasing rapidly to meet the demands of the ultra-high-resolution, large panel size and three dimensional visual effects as a megatrend of flat panel displays, such as liquid crystal displays, organic light emitting diodes and flexible displays. In this regard, the effects of the TMO composition on the performance of the resulting oxide TFTs has been reviewed, and classified into binary, ternary and quaternary composition systems. In addition, the new strategic approaches including zinc oxynitride materials, double channel structures, and composite structures have been proposed recently, and were not covered in detail in previous review papers. Special attention is given to the advanced device architecture of TMO TFTs, such as back-channel-etch and self-aligned coplanar structure, which is a key technology because of their advantages including low cost fabrication, high driving speed and unwanted visual artifact-free high quality imaging. The integration process and related issues, such as etching, post treatment, low ohmic contact and Cu interconnection, required for realizing these advanced architectures are also discussed.

  17. Prospects of high-resolution resonant X-ray inelastic scattering studies on solid materials, liquids and gases at diffraction-limited storage rings.

    PubMed

    Schmitt, Thorsten; de Groot, Frank M F; Rubensson, Jan Erik

    2014-09-01

    The spectroscopic technique of resonant inelastic X-ray scattering (RIXS) will particularly profit from immensely improved brilliance of diffraction-limited storage rings (DLSRs). In RIXS one measures the intensities of excitations as a function of energy and momentum transfer. DLSRs will allow for pushing the achievable energy resolution, signal intensity and the sampled spot size to new limits. With RIXS one nowadays probes a broad range of electronic systems reaching from simple molecules to complex materials displaying phenomena like peculiar magnetism, two-dimensional electron gases, superconductivity, photovoltaic energy conversion and heterogeneous catalysis. In this article the types of improved RIXS studies that will become possible with X-ray beams from DLSRs are envisioned.

  18. Image display device in digital TV

    DOEpatents

    Choi, Seung Jong [Seoul, KR

    2006-07-18

    Disclosed is an image display device in a digital TV that is capable of carrying out the conversion into various kinds of resolution by using single bit map data in the digital TV. The image display device includes: a data processing part for executing bit map conversion, compression, restoration and format-conversion for text data; a memory for storing the bit map data obtained according to the bit map conversion and compression in the data processing part and image data inputted from an arbitrary receiving part, the receiving part receiving one of digital image data and analog image data; an image outputting part for reading the image data from the memory; and a display processing part for mixing the image data read from the image outputting part and the bit map data converted in format from the a data processing part. Therefore, the image display device according to the present invention can convert text data in such a manner as to correspond with various resolution, carry out the compression for bit map data, thereby reducing the memory space, and support text data of an HTML format, thereby providing the image with the text data of various shapes.

  19. Soccer Offside Judgments in Laypersons with Different Types of Static Displays

    PubMed Central

    Wühr, Peter; Fasold, Frowin; Memmert, Daniel

    2015-01-01

    Four experiments investigated offside decisions in laypersons with different types of static displays. Previous research neglected this group although the majority of assistant referees in soccer games at the amateur level are laypersons. The aims of our research were (a) to investigate the spatial resolution in laypersons’ perception of offside situations, (b) to search for biases in laypersons’ offside judgments, and (c) to develop useful displays for future research. The displays showed the moment when a midfielder passes the ball to a forward moving in the vicinity of a defender. We varied the spatial location of the forward around the defender in eleven steps and participants made their offside decision by pressing a key. Across experiments, displays varied in abstractness (simple shapes, clipart figures, photographs). There were two major findings. Firstly, both accuracy and speed of offside judgments deteriorated when the spatial distance between forward and defender decreased, approaching guessing rate at the smallest distances. Secondly, participants showed a consistent bias in favor of the non-offside response, in contrast to most studies on professional assistant referees. In sum, the results highlight the limited spatial resolution of the visual system and underscore the role of response bias in offside-judgment tasks. PMID:26252653

  20. Geomorphological Mapping of Sputnik Planum and Surrounding Terrain on Pluto

    NASA Astrophysics Data System (ADS)

    White, Oliver; Stern, Alan; Weaver, Hal; Olkin, Cathy; Ennico, Kimberly; Young, Leslie; Moore, Jeff

    2015-11-01

    The New Horizons flyby of Pluto in July 2015 has provided the first few close-up images of the Kuiper belt object, which reveal it to have a highly diverse range of terrains, implying a complex geological history. The highest resolution images that have yet been returned are seven lossy 400 m/pixel frames that cover the majority of the prominent Plutonian feature informally named Sputnik Planum (all feature names are currently informal), and its surroundings. This resolution is sufficient to allow detailed geomorphological mapping of this area to commence. Lossless versions of all 15 frames that make up the mosaic will be returned in September 2015, and the map presented at DPS will incorporate the total area covered by these frames.Sputnik Planum, with an area of ~650,000 km2, is notable for its smooth appearance and apparent total lack of impact craters at 400 m/pixel resolution. The Planum actually displays a wide variety of textures across its expanse, which includes smooth and pitted plains to the south, polygonal terrain at its center (the polygons can reach tens of kilometers in size and are bounded by troughs that sometimes feature central ridges), and, to the north, darker polygonal terrain displaying patterns indicative of glacial flow. Within these plains there exist several well-defined outcrops of a mottled, light/dark unit that reach from several to tens of kilometers across. Separating Sputnik Planum from the dark, cratered equatorial terrain of Cthulhu Regio on its south-western margin is a unit of chaotically arranged mountains (Hillary Montes); similar mountainous units exist on the south and western margins. The northern margin is bounded by rugged, hilly, cratered terrain (Cousteau Rupes) into which ice of Sputnik Planum appears to be intruding in places. Terrain of similar relief exists to the east, but is much brighter than that to the north. The southernmost extent of the mosaic features a unit of rough, undulating terrain (Pandemonium Dorsa) that displays very few impact craters at 400 m/pixel resolution.This work was supported by the NASA New Horizons project.

  1. SOT: A rapid prototype using TAE windows

    NASA Technical Reports Server (NTRS)

    Stephens, Mark; Eike, David; Harris, Elfrieda; Miller, Dana

    1986-01-01

    The development of the window interface extension feature of the Transportable Applications Executive (TAE) is discussed. This feature is being used to prototype a space station payload interface in order to demonstrate and assess the benefits of using windows on a bit mapped display and also to convey the concept of telescience, the control and operation of space station payloads from remote sites. The prototype version of the TAE with windows operates on a DEC VAXstation 100. This workstation has a high resolution 19 inch bit mapped display, a keyboard and a three-button mouse. The VAXstation 100 is not a stand-alone workstation, but is controlled by software executing on a VAX/8600. A short scenario was developed utilizing the Solar Optical Telescope (SOT) as an example payload. In the scenario the end-user station includes the VAXstation 100 plus an image analysis terminal used to display the CCD images. The layout and use of the prototype elements, i.e., the root menu, payload status window, and target acquisition menu is described.

  2. JuxtaView - A tool for interactive visualization of large imagery on scalable tiled displays

    USGS Publications Warehouse

    Krishnaprasad, N.K.; Vishwanath, V.; Venkataraman, S.; Rao, A.G.; Renambot, L.; Leigh, J.; Johnson, A.E.; Davis, B.

    2004-01-01

    JuxtaView is a cluster-based application for viewing ultra-high-resolution images on scalable tiled displays. We present in JuxtaView, a new parallel computing and distributed memory approach for out-of-core montage visualization, using LambdaRAM, a software-based network-level cache system. The ultimate goal of JuxtaView is to enable a user to interactively roam through potentially terabytes of distributed, spatially referenced image data such as those from electron microscopes, satellites and aerial photographs. In working towards this goal, we describe our first prototype implemented over a local area network, where the image is distributed using LambdaRAM, on the memory of all nodes of a PC cluster driving a tiled display wall. Aggressive pre-fetching schemes employed by LambdaRAM help to reduce latency involved in remote memory access. We compare LambdaRAM with a more traditional memory-mapped file approach for out-of-core visualization. ?? 2004 IEEE.

  3. Processing Infrared Images For Fire Management Applications

    NASA Astrophysics Data System (ADS)

    Warren, John R.; Pratt, William K.

    1981-12-01

    The USDA Forest Service has used airborne infrared systems for forest fire detection and mapping for many years. The transfer of the images from plane to ground and the transposition of fire spots and perimeters to maps has been performed manually. A new system has been developed which uses digital image processing, transmission, and storage. Interactive graphics, high resolution color display, calculations, and computer model compatibility are featured in the system. Images are acquired by an IR line scanner and converted to 1024 x 1024 x 8 bit frames for transmission to the ground at a 1.544 M bit rate over a 14.7 GHZ carrier. Individual frames are received and stored, then transferred to a solid state memory to refresh the display at a conventional 30 frames per second rate. Line length and area calculations, false color assignment, X-Y scaling, and image enhancement are available. Fire spread can be calculated for display and fire perimeters plotted on maps. The performance requirements, basic system, and image processing will be described.

  4. McIDAS-V: A Data Analysis and Visualization Tool for Global Satellite Data

    NASA Astrophysics Data System (ADS)

    Achtor, T. H.; Rink, T. D.

    2011-12-01

    The Man-computer Interactive Data Access System (McIDAS-V) is a java-based, open-source, freely available system for scientists, researchers and algorithm developers working with atmospheric data. The McIDAS-V software tools provide powerful new data manipulation and visualization capabilities, including 4-dimensional displays, an abstract data model with integrated metadata, user defined computation, and a powerful scripting capability. As such, McIDAS-V is a valuable tool for scientists and researchers within the GEO and GOESS domains. The advancing polar and geostationary orbit environmental satellite missions conducted by several countries will carry advanced instrumentation and systems that will collect and distribute land, ocean, and atmosphere data. These systems provide atmospheric and sea surface temperatures, humidity sounding, cloud and aerosol properties, and numerous other environmental products. This presentation will display and demonstrate some of the capabilities of McIDAS-V to analyze and display high temporal and spectral resolution data using examples from international environmental satellites.

  5. Impact of automatic calibration techniques on HMD life cycle costs and sustainable performance

    NASA Astrophysics Data System (ADS)

    Speck, Richard P.; Herz, Norman E., Jr.

    2000-06-01

    Automatic test and calibration has become a valuable feature in many consumer products--ranging from antilock braking systems to auto-tune TVs. This paper discusses HMDs (Helmet Mounted Displays) and how similar techniques can reduce life cycle costs and increase sustainable performance if they are integrated into a program early enough. Optical ATE (Automatic Test Equipment) is already zeroing distortion in the HMDs and thereby making binocular displays a practical reality. A suitcase sized, field portable optical ATE unit could re-zero these errors in the Ready Room to cancel the effects of aging, minor damage and component replacement. Planning on this would yield large savings through relaxed component specifications and reduced logistic costs. Yet, the sustained performance would far exceed that attained with fixed calibration strategies. Major tactical benefits can come from reducing display errors, particularly in information fusion modules and virtual `beyond visual range' operations. Some versions of the ATE described are in production and examples of high resolution optical test data will be discussed.

  6. A system for tracking braille readers using a Wii Remote and a refreshable braille display.

    PubMed

    Aranyanak, Inthraporn; Reilly, Ronan G

    2013-03-01

    This article describes a cheap and easy-to-use finger-tracking system for studying braille reading. It provides improved spatial and temporal resolution over the current available solutions and can be used with either a refreshable braille display or braille-embossed paper. In conjunction with a refreshable braille display, the tracking system has the unique capacity to implement display-change paradigms derived from sighted reading research. This will allow researchers to probe skilled braille reading in significantly more depth than has heretofore been possible.

  7. cisTEM, user-friendly software for single-particle image processing.

    PubMed

    Grant, Timothy; Rohou, Alexis; Grigorieff, Nikolaus

    2018-03-07

    We have developed new open-source software called cis TEM (computational imaging system for transmission electron microscopy) for the processing of data for high-resolution electron cryo-microscopy and single-particle averaging. cis TEM features a graphical user interface that is used to submit jobs, monitor their progress, and display results. It implements a full processing pipeline including movie processing, image defocus determination, automatic particle picking, 2D classification, ab-initio 3D map generation from random parameters, 3D classification, and high-resolution refinement and reconstruction. Some of these steps implement newly-developed algorithms; others were adapted from previously published algorithms. The software is optimized to enable processing of typical datasets (2000 micrographs, 200 k - 300 k particles) on a high-end, CPU-based workstation in half a day or less, comparable to GPU-accelerated processing. Jobs can also be scheduled on large computer clusters using flexible run profiles that can be adapted for most computing environments. cis TEM is available for download from cistem.org. © 2018, Grant et al.

  8. High-resolution Self-Organizing Maps for advanced visualization and dimension reduction.

    PubMed

    Saraswati, Ayu; Nguyen, Van Tuc; Hagenbuchner, Markus; Tsoi, Ah Chung

    2018-05-04

    Kohonen's Self Organizing feature Map (SOM) provides an effective way to project high dimensional input features onto a low dimensional display space while preserving the topological relationships among the input features. Recent advances in algorithms that take advantages of modern computing hardware introduced the concept of high resolution SOMs (HRSOMs). This paper investigates the capabilities and applicability of the HRSOM as a visualization tool for cluster analysis and its suitabilities to serve as a pre-processor in ensemble learning models. The evaluation is conducted on a number of established benchmarks and real-world learning problems, namely, the policeman benchmark, two web spam detection problems, a network intrusion detection problem, and a malware detection problem. It is found that the visualization resulted from an HRSOM provides new insights concerning these learning problems. It is furthermore shown empirically that broad benefits from the use of HRSOMs in both clustering and classification problems can be expected. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. cisTEM, user-friendly software for single-particle image processing

    PubMed Central

    2018-01-01

    We have developed new open-source software called cisTEM (computational imaging system for transmission electron microscopy) for the processing of data for high-resolution electron cryo-microscopy and single-particle averaging. cisTEM features a graphical user interface that is used to submit jobs, monitor their progress, and display results. It implements a full processing pipeline including movie processing, image defocus determination, automatic particle picking, 2D classification, ab-initio 3D map generation from random parameters, 3D classification, and high-resolution refinement and reconstruction. Some of these steps implement newly-developed algorithms; others were adapted from previously published algorithms. The software is optimized to enable processing of typical datasets (2000 micrographs, 200 k – 300 k particles) on a high-end, CPU-based workstation in half a day or less, comparable to GPU-accelerated processing. Jobs can also be scheduled on large computer clusters using flexible run profiles that can be adapted for most computing environments. cisTEM is available for download from cistem.org. PMID:29513216

  10. The Use of HDTV Format and the Electronic Theater in Presenting Earth Science

    NASA Technical Reports Server (NTRS)

    Summey, Barbara; Hasler, Arthur; Jentoft-Nilsen, Marit; Manyin, Michael; Bene, Meredith; Allen, Jesse

    2000-01-01

    In order to maximize the public's awareness of earth science observations, earth science data must be available in multiple media formats. This talk will focus on the use High Definition TV format in presenting earth science data, The Television (HDTV) networks are mandated to completely switch over from the current TV standard (NTSC) to HDTV in the next seven years. Museums are also beginning to use HDTV format in their displays. The Visualization Analysis Laboratory at Goddard Space Flight Center has been experimenting with the use of HDTV to present earth science data. The experimental package we have developed is called the Electronic Theater (e-theater). The e-theater is a mobile presentation system used for displaying and teaching groups about earth science and the delicate interdependence between the various earth systems. The e-theater takes advantage of a double-wide screen to show the audiences high resolution data displays. The unique architecture used in this exhibit allows several data sets to be displayed at one time, demonstrating the connections between different earth systems. The data animations are manipulated in real-time during the presentation and can be paused, moved forward, backward, looped, or zoomed into, to maximize the flexibility of the presentation. Because HDTV format is used within the e-theater, the materials generated for the e-theater are made available to the news media and museums.

  11. Two New Aircraft Traffic Surveillance Symbology Concepts: Range Filter and Inboard Field-of-View Symbology

    NASA Technical Reports Server (NTRS)

    Wong, Douglas T.; Kramer, Lynda J.; Norman, R. Michael

    2001-01-01

    The objective of this preliminary experiment was to investigate two head-up surveillance symbology (HUSS) display issues. The first issue was concerned with the benefits of adding a range filter to the current HUSS concept. A range filter limits the amount of traffic symbols displayed head-up by setting a range boundary (e.g., 7-nmi) around the ownship. The second issue was concerned with the need to incorporate HUSS in the inboard field-of-view (IFOV) display of the eXternal Visibility System (XVS) concept. The hypothesis tested was that adding a range filter to the XVS display and HUSS to the IFOV display would enhance the pilot's effectiveness in traffic surveillance tasks. Using a high-resolution graphics flight simulator, each of three pilots flew departure and arrival scenarios under visual meteorological conditions. The pilots' main tasks, while managing flight path, were to detect and assess potential airborne traffic hazards and to maintain overall situation awareness. Upon completing all the runs, each pilot completed a subjective questionnaire. Results showed that having both the HUSS on the IFOV and the range filter on each of the XVS displays enhanced the effectiveness of the XVS surveillance display concept. This configuration had the least head down time and the lowest mental workload. Combining both features gave the best target detection and, the earliest threat recognition performances, and enabled the pilots to create a better strategy for evasive action when it became necessary.

  12. Accommodative performance for chromatic displays.

    PubMed

    Lovasik, J V; Kergoat, H

    1988-01-01

    Over the past few years, video display units (VDUs) have been incorporated into many varieties of workplaces and occupational demands. The success of electro-optical displays in facilitating and improving job performance has spawned interest in extracting further advantage from VDUs by incorporating colour coding into such communication systems. However, concerns have been raised about the effect of chromatic stimuli on the visual comfort and task efficiency, because of the chromatic aberration inherent in the optics of the human eye. In this study, we used a computer aided laser speckle optometer system to measure the accommodative responses to brightness-matched chromatic letters displayed on a high-resolution RGB monitor. Twenty, visually normal, paid volunteers in a 22-35 year age category served as subjects. Stimuli were 14, 21, 28 minutes of arc letters presented in a 'monochromatic' (white, red, green or blue, on a black background) or 'multichromatic' (blue-red, blue-green, red-green, foreground-background combinations) mode at 40 and 80 cm viewing distances. The results demonstrated that while the accommodative responses were strongly influenced by the foreground-background colour combination, the group-averaged dioptric difference across colours was relatively small. Further, accommodative responses were not guided in any systematic fashion by the size of letters presented for fixation. Implications of these findings for display designs are discussed.

  13. Volumetric three-dimensional display system with rasterization hardware

    NASA Astrophysics Data System (ADS)

    Favalora, Gregg E.; Dorval, Rick K.; Hall, Deirdre M.; Giovinco, Michael; Napoli, Joshua

    2001-06-01

    An 8-color multiplanar volumetric display is being developed by Actuality Systems, Inc. It will be capable of utilizing an image volume greater than 90 million voxels, which we believe is the greatest utilizable voxel set of any volumetric display constructed to date. The display is designed to be used for molecular visualization, mechanical CAD, e-commerce, entertainment, and medical imaging. As such, it contains a new graphics processing architecture, novel high-performance line- drawing algorithms, and an API similar to a current standard. Three-dimensional imagery is created by projecting a series of 2-D bitmaps ('image slices') onto a diffuse screen that rotates at 600 rpm. Persistence of vision fuses the slices into a volume-filling 3-D image. A modified three-panel Texas Instruments projector provides slices at approximately 4 kHz, resulting in 8-color 3-D imagery comprised of roughly 200 radially-disposed slices which are updated at 20 Hz. Each slice has a resolution of 768 by 768 pixels, subtending 10 inches. An unusual off-axis projection scheme incorporating tilted rotating optics is used to maintain good focus across the projection screen. The display electronics includes a custom rasterization architecture which converts the user's 3- D geometry data into image slices, as well as 6 Gbits of DDR SDRAM graphics memory.

  14. Perception of 3D spatial relations for 3D displays

    NASA Astrophysics Data System (ADS)

    Rosen, Paul; Pizlo, Zygmunt; Hoffmann, Christoph; Popescu, Voicu S.

    2004-05-01

    We test perception of 3D spatial relations in 3D images rendered by a 3D display (Perspecta from Actuality Systems) and compare it to that of a high-resolution flat panel display. 3D images provide the observer with such depth cues as motion parallax and binocular disparity. Our 3D display is a device that renders a 3D image by displaying, in rapid succession, radial slices through the scene on a rotating screen. The image is contained in a glass globe and can be viewed from virtually any direction. In the psychophysical experiment several families of 3D objects are used as stimuli: primitive shapes (cylinders and cuboids), and complex objects (multi-story buildings, cars, and pieces of furniture). Each object has at least one plane of symmetry. On each trial an object or its "distorted" version is shown at an arbitrary orientation. The distortion is produced by stretching an object in a random direction by 40%. This distortion must eliminate the symmetry of an object. The subject's task is to decide whether or not the presented object is distorted under several viewing conditions (monocular/binocular, with/without motion parallax, and near/far). The subject's performance is measured by the discriminability d', which is a conventional dependent variable in signal detection experiments.

  15. The Metalloprotease Mpl Supports Listeria monocytogenes Dissemination through Resolution of Membrane Protrusions into Vacuoles

    PubMed Central

    Alvarez, Diego E.

    2016-01-01

    Listeria monocytogenes is an intracellular pathogen that disseminates within the intestinal epithelium through acquisition of actin-based motility and formation of plasma membrane protrusions that project into adjacent cells. The resolution of membrane protrusions into vacuoles from which the pathogen escapes results in bacterial spread from cell to cell. This dissemination process relies on the mlp-actA-plcB operon, which encodes ActA, a bacterial nucleation-promoting factor that mediates actin-based motility, and PlcB, a phospholipase that mediates vacuole escape. Here we investigated the role of the metalloprotease Mpl in the dissemination process. In agreement with previous findings showing that Mpl is required for PlcB activation, infection of epithelial cells with the ΔplcB or Δmpl strains resulted in the formation of small infection foci. As expected, the ΔplcB strain displayed a strong defect in vacuole escape. However, the Δmpl strain showed an unexpected defect in the resolution of protrusions into vacuoles, in addition to the expected but mild defect in vacuole escape. The Δmpl strain displayed increased levels of ActA on the bacterial surface in protrusions. We mapped an Mpl-dependent processing site in ActA between amino acid residues 207 to 238. Similar to the Δmpl strain, the ΔactA207–238 strain displayed increased levels of ActA on the bacterial surface in protrusions. Although the ΔactA207–238 strain displayed wild-type actin-based motility, it formed small infection foci and failed to resolve protrusions into vacuoles. We propose that, in addition to its role in PlcB processing and vacuole escape, the metalloprotease Mpl is required for ActA processing and protrusion resolution. PMID:27068088

  16. The Metalloprotease Mpl Supports Listeria monocytogenes Dissemination through Resolution of Membrane Protrusions into Vacuoles.

    PubMed

    Alvarez, Diego E; Agaisse, Hervé

    2016-06-01

    Listeria monocytogenes is an intracellular pathogen that disseminates within the intestinal epithelium through acquisition of actin-based motility and formation of plasma membrane protrusions that project into adjacent cells. The resolution of membrane protrusions into vacuoles from which the pathogen escapes results in bacterial spread from cell to cell. This dissemination process relies on the mlp-actA-plcB operon, which encodes ActA, a bacterial nucleation-promoting factor that mediates actin-based motility, and PlcB, a phospholipase that mediates vacuole escape. Here we investigated the role of the metalloprotease Mpl in the dissemination process. In agreement with previous findings showing that Mpl is required for PlcB activation, infection of epithelial cells with the ΔplcB or Δmpl strains resulted in the formation of small infection foci. As expected, the ΔplcB strain displayed a strong defect in vacuole escape. However, the Δmpl strain showed an unexpected defect in the resolution of protrusions into vacuoles, in addition to the expected but mild defect in vacuole escape. The Δmpl strain displayed increased levels of ActA on the bacterial surface in protrusions. We mapped an Mpl-dependent processing site in ActA between amino acid residues 207 to 238. Similar to the Δmpl strain, the ΔactA207-238 strain displayed increased levels of ActA on the bacterial surface in protrusions. Although the ΔactA207-238 strain displayed wild-type actin-based motility, it formed small infection foci and failed to resolve protrusions into vacuoles. We propose that, in addition to its role in PlcB processing and vacuole escape, the metalloprotease Mpl is required for ActA processing and protrusion resolution. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  17. Microcomputer Selection Guide for Construction Field Offices. Revision.

    DTIC Science & Technology

    1984-09-01

    the system, and the monitor displays information on a video display screen. Microcomputer systems today are available in a variety of configura- tions...background. White on black monitors report- edly caule more eye fatigue, while amber is reported to cause the least eye fatigue. Reverse video ...The video should be amber or green display with a resolution of at least 640 x 200 dots per in. Additional features of the monitor include an

  18. Climate change and social vicissitudes in China over the past two millennia

    NASA Astrophysics Data System (ADS)

    Yin, Jun; Su, Yun; Fang, Xiuqi

    2016-09-01

    The relation between climate change and historical rhythms has long been discussed. However, this type of study still faces the lack of high-resolution data concerning long-term socio-economic processes. In this study, we collected 1586 items of direct and proffered evidence from 29 Chinese history books. We used semantic analysis to reconstruct a quantitative series of the social vicissitudes of the past 2000 yr with a 10-yr resolution to express the phase transition of the social vicissitudes of the dynasties in China. Our reconstruction demonstrates that social vicissitudes have clear cyclical features on multiple time scales. Analysis of the association of social rise and fall with climate change indicates that temperature displayed more significant effects on social vicissitudes in the long term, while precipitation displayed more significant effects on the social vicissitudes in the short term. There are great overlaps between social and climatic variables around the predominant or periodic bands. Social rise mostly occurred in the centennial-scale warm periods, whereas social decline mostly occurred in the centennial-scale cold periods. Under warm-wet conditions, social rise occurred over 57% of the time; under cold-dry conditions, the social decline occurred over 66% of the time.

  19. Application of the phase extension method in virus crystallography.

    PubMed

    Reddy, Vijay S

    2016-01-01

    The procedure for phase extension (PX) involves gradually extending the initial phases from low resolution (e.g., ~8Å) to the high-resolution limit of a diffraction data set. Structural redundancy present in the viral capsids that display icosahedral symmetry results in a high degree of non-crystallographic symmetry (NCS), which in turn translates into higher phasing power and is critical for improving and extending phases to higher resolution. Greater completeness of the diffraction data and determination of a molecular replacement solution, which entails accurately identifying the virus particle orientation(s) and position(s), are important for the smooth progression of the PX procedure. In addition, proper definition of a molecular mask (envelope) around the NCS-asymmetric unit has been found to be important for the success of density modification procedures, such as density averaging and solvent flattening. Regardless of the degree of NCS, the PX method appears to work well in all space groups, provided an accurate molecular mask is used along with reasonable initial phases. However, in the cases with space group P1, in addition to requiring a molecular mask, starting the phase extension at a higher resolution (e.g., 6Å) overcame the previously reported problems due to Babinet phases and phase flipping errors.

  20. High-resolution polarization sensitive OCT for ocular imaging in rodents

    NASA Astrophysics Data System (ADS)

    Fialová, Stanislava; Rauscher, Sabine; Gröger, Marion; Pircher, Michael; Hitzenberger, Christoph K.; Baumann, Bernhard

    2015-03-01

    A new high-resolution polarization sensitive optical coherence tomography system was developed for imaging rodent retina. Various light-tissue interactions such as birefringence and depolarization can change the polarization state of light. In the eye, there are several tissues that have these properties, for example retinal pigment epithelium (depolarization) and sclera (birefringence). These layers play key roles in diseases like age-related macular degeneration or glaucoma. Animal models are an important component for understanding disease pathogenesis. The gold standard for the evaluation of preclinical experiments is histology, which is an invasive and terminal procedure. Since OCT is non-invasive, it has the potential to be an alternative to histology with the benefit of long-term study of the disease progression in the same animal. In this study, a superluminescent diode with spectrum width 100 nm and mean wavelength 840 nm is used as a light source in order to enable high axial resolution. Spectrometers are custom built to enable high imaging speed that allows acquiring 3D data sets with 1024x200x1536 voxels in 3.44 s. From the acquired data, images displaying phase retardation induced by birefringence and orientation of birefringent axis were calculated. In first measurements, we were able to identify the RPE-choroid complex (depolarization effect) and the sclera (strong birefringence) in the retina of Long-Evans and Sprague-Dawley rats. Our preliminary results demonstrate the feasibility of the system for high speed/resolution imaging of the rodent retina. This is useful for longitudinal studies of disease models of retinal disease in rats and mice

  1. The x-ray light valve: a low-cost, digital radiographic imaging system-spatial resolution

    NASA Astrophysics Data System (ADS)

    MacDougall, Robert D.; Koprinarov, Ivaylo; Webster, Christie A.; Rowlands, J. A.

    2007-03-01

    In recent years, new x-ray radiographic systems based on large area flat panel technology have revolutionized our capability to produce digital x-ray radiographic images. However, these active matrix flat panel imagers (AMFPIs) are extraordinarily expensive compared to the systems they are replacing. Thus there is a need for a low cost digital imaging system for general applications in radiology. Different approaches have been considered to make lower cost, integrated x-ray imaging devices for digital radiography, including: scanned projection x-ray, an integrated approach based on computed radiography technology and optically demagnified x-ray screen/CCD systems. These approaches suffer from either high cost or high mechanical complexity and do not have the image quality of AMFPIs. We have identified a new approach - the X-ray Light Valve (XLV). The XLV has the potential to achieve the immediate readout in an integrated system with image quality comparable to AMFPIs. The XLV concept combines three well-established and hence lowcost technologies: an amorphous selenium (a-Se) layer to convert x-rays to image charge, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. Here we investigate the spatial resolution possible with XLV systems. Both a-Se and LC cells have both been shown separately to have inherently very high spatial resolution. Due to the close electrostatic coupling in the XLV, it can be expected that the spatial resolution of this system will also be very high. A prototype XLV was made and a typical office scanner was used for image digitization. The Modulation Transfer Function was measured and the limiting factor was seen to be the optical scanner. However, even with this limitation the XLV system is able to meet or exceed the resolution requirements for chest radiography.

  2. Augmenting reality in Direct View Optical (DVO) overlay applications

    NASA Astrophysics Data System (ADS)

    Hogan, Tim; Edwards, Tim

    2014-06-01

    The integration of overlay displays into rifle scopes can transform precision Direct View Optical (DVO) sights into intelligent interactive fire-control systems. Overlay displays can provide ballistic solutions within the sight for dramatically improved targeting, can fuse sensor video to extend targeting into nighttime or dirty battlefield conditions, and can overlay complex situational awareness information over the real-world scene. High brightness overlay solutions for dismounted soldier applications have previously been hindered by excessive power consumption, weight and bulk making them unsuitable for man-portable, battery powered applications. This paper describes the advancements and capabilities of a high brightness, ultra-low power text and graphics overlay display module developed specifically for integration into DVO weapon sight applications. Central to the overlay display module was the development of a new general purpose low power graphics controller and dual-path display driver electronics. The graphics controller interface is a simple 2-wire RS-232 serial interface compatible with existing weapon systems such as the IBEAM ballistic computer and the RULR and STORM laser rangefinders (LRF). The module features include multiple graphics layers, user configurable fonts and icons, and parameterized vector rendering, making it suitable for general purpose DVO overlay applications. The module is configured for graphics-only operation for daytime use and overlays graphics with video for nighttime applications. The miniature footprint and ultra-low power consumption of the module enables a new generation of intelligent DVO systems and has been implemented for resolutions from VGA to SXGA, in monochrome and color, and in graphics applications with and without sensor video.

  3. An Evaluation of Performance Characteristics of Primary Display Devices.

    PubMed

    Ekpo, Ernest U; McEntee, Mark F

    2016-04-01

    The aim of this study was to complete a full evaluation of the new EIZO RX850 liquid crystal display and compare it to two currently used medical displays in Australia (EIZO GS510 and Barco MDCG 5121). The American Association of Physicists in Medicine (AAPM) Task Group 18 Quality Control test pattern was used to assess the performance of three high-resolution primary medical displays: EIZO RX850, EIZO GS510, and Barco MDCG 5121. A Konica Minolta spectroradiometer (CS-2000) was used to assess luminance response, non-uniformity, veiling glare, and color uniformity. Qualitative evaluation of noise was also performed. Seven breast lesions were displayed on each monitor and photographed with a calibrated 5.5-MP Olympus E-1 digital SLR camera. ImageJ software was used to sample pixel information from each lesion and surrounding background to calculate their conspicuity index on each of the displays. All monitor fulfilled all AAPM acceptance criteria. The performance characteristics for EIZO RX850, Barco MDCG 5121, and EIZO GS510 respectively were as follows: maximum luminance (490, 500.5, and 413 cd/m(2)), minimum luminance (0.724, 1.170, and 0.92 cd/m(2)), contrast ratio (675:1, 428:1, 449:1), just-noticeable difference index (635, 622, 609), non-uniformity (20, 5.92, and 8.5 %), veiling glare (GR = 2465.6, 720.4, 1249.8), and color uniformity (Δu'v' = +0.003, +0.002, +0.002). All monitors demonstrated low noise levels. The conspicuity index (χ) of the lesions was slightly higher in the EIZO RX850 display. All medical displays fulfilled AAPM performance criteria, and performance characteristics of EIZO RX850 are equal to or better than those of the Barco MDCG 5121 and EIZO GS510 displays.

  4. Horizontal Conflict Resolution Maneuvers with a Cockpit Display of Traffic Information

    NASA Technical Reports Server (NTRS)

    Palmer, E.; Jago, S.; Dubord, M.

    1981-01-01

    Pilot resolution of potential conflicts in the horizontal plane when the only information available on the other aircraft was presented on a Cockpit Display of Traffic Information (CDTI) is investigated. The pilot's task was to assess the situation and if necessary maneuver so as to avoid the other aircraft. No instructions were given on evasive strategy or on what was considered to be an acceptable minimum separation. The results indicate that pilots had a strong bias of turning toward the intruder aircraft in order to pass behind it. In more than 50% of the encounters with a 90 degree crossing angle in which the intruder aircraft was programmed to pass behind the aircraft, the pilots maneuvered so as to pass behind the intruder. This bias was not as strong with the display which showed a prediction of the intruder's relative velocity. The average miss distance for all encounters was about 4500 feet.

  5. The IQ-wall and IQ-station -- harnessing our collective intelligence to realize the potential of ultra-resolution and immersive visualization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eric A. Wernert; William R. Sherman; Chris Eller

    2012-03-01

    We present a pair of open-recipe, affordably-priced, easy-to-integrate, and easy-to-use visualization systems. The IQ-wall is an ultra-resolution tiled display wall that scales up to 24 screens with a single PC. The IQ-station is a semi-immersive display system that utilizes commodity stereoscopic displays, lower cost tracking systems, and touch overlays. These systems have been designed to support a wide range of research, education, creative activities, and information presentations. They were designed to work equally well as stand-alone installations or as part of a larger distributed visualization ecosystem. We detail the hardware and software components of these systems, describe our deployments andmore » experiences in a variety of research lab and university environments, and share our insights for effective support and community development.« less

  6. Preparative resolution of D,L-threonine catalyzed by immobilized phosphatase.

    PubMed

    Scollar, M P; Sigal, G; Klibanov, A M

    1985-03-01

    Hydrolysis of L- and D-O-phosphothreonines catalyzed by four different phosphatases, alkaline phosphatases from calf intestine and E. coli and acid phosphatases from wheat germ and potato, has been kinetically studied. Alkaline phosphatases were found to have comparable reactivities towards the optical isomers. On the other hand, both acid phosphatases displayed a marked stereoselectivity, hydrolyzing the L-ester much faster than its D counterpart. Wheat germ acid phosphatase was the most stereoselective enzyme: V(L)/V(D) = 24 and K(m,L)/K(m,D) = 0.17. This enzyme was immobilized (in k-carrageenan gel, followed by crosslinking with glutaraldehyde) and used for the preparative resolution of D,L-threonine: the latter was first chemically O-phosphorylated and then asymmetrically hydrolyzed by the immobilized phosphatase. As a result, gram quantities of L-threonine of high optical purity and O-phospho-D-threonine were prepared. Immobilized wheat germ phosphatase has been tested for the resolution of other racemic alcohols: serine, 2-amino-1-butanol, 1-amino-2-propanol, 2-octanol, and menthol. In all those cases, the enzyme was either not sufficiently stereoselective or too slow for preparative resolutions.

  7. Camera calibration: active versus passive targets

    NASA Astrophysics Data System (ADS)

    Schmalz, Christoph; Forster, Frank; Angelopoulou, Elli

    2011-11-01

    Traditionally, most camera calibrations rely on a planar target with well-known marks. However, the localization error of the marks in the image is a source of inaccuracy. We propose the use of high-resolution digital displays as active calibration targets to obtain more accurate calibration results for all types of cameras. The display shows a series of coded patterns to generate correspondences between world points and image points. This has several advantages. No special calibration hardware is necessary because suitable displays are practically ubiquitious. The method is fully automatic, and no identification of marks is necessary. For a coding scheme based on phase shifting, the localization accuracy is approximately independent of the camera's focus settings. Most importantly, higher accuracy can be achieved compared to passive targets, such as printed checkerboards. A rigorous evaluation is performed to substantiate this claim. Our active target method is compared to standard calibrations using a checkerboard target. We perform camera, calibrations with different combinations of displays, cameras, and lenses, as well as with simulated images and find markedly lower reprojection errors when using active targets. For example, in a stereo reconstruction task, the accuracy of a system calibrated with an active target is five times better.

  8. Split-screen display system and standardized methods for ultrasound image acquisition and multi-frame data processing

    NASA Technical Reports Server (NTRS)

    Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)

    2011-01-01

    A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.

  9. Engineering of Semiconductor Nanocrystals for Light Emitting Applications

    PubMed Central

    Todescato, Francesco; Fortunati, Ilaria; Minotto, Alessandro; Signorini, Raffaella; Jasieniak, Jacek J.; Bozio, Renato

    2016-01-01

    Semiconductor nanocrystals are rapidly spreading into the display and lighting markets. Compared with liquid crystal and organic LED displays, nanocrystalline quantum dots (QDs) provide highly saturated colors, wide color gamut, resolution, rapid response time, optical efficiency, durability and low cost. This remarkable progress has been made possible by the rapid advances in the synthesis of colloidal QDs and by the progress in understanding the intriguing new physics exhibited by these nanoparticles. In this review, we provide support to the idea that suitably engineered core/graded-shell QDs exhibit exceptionally favorable optical properties, photoluminescence and optical gain, while keeping the synthesis facile and producing QDs well suited for light emitting applications. Solid-state laser emitters can greatly profit from QDs as efficient gain materials. Progress towards fabricating low threshold, solution processed DFB lasers that are optically pumped using one- and two-photon absorption is reviewed. In the field of display technologies, the exploitation of the exceptional photoluminescence properties of QDs for LCD backlighting has already advanced to commercial levels. The next big challenge is to develop the electroluminescence properties of QD to a similar state. We present an overview of QLED devices and of the great perspectives for next generation display and lighting technologies. PMID:28773794

  10. Intelligent Visual Input: A Graphical Method for Rapid Entry of Patient-Specific Data

    PubMed Central

    Bergeron, Bryan P.; Greenes, Robert A.

    1987-01-01

    Intelligent Visual Input (IVI) provides a rapid, graphical method of data entry for both expert system interaction and medical record keeping purposes. Key components of IVI include: a high-resolution graphic display; an interface supportive of rapid selection, i.e., one utilizing a mouse or light pen; algorithm simplification modules; and intelligent graphic algorithm expansion modules. A prototype IVI system, designed to facilitate entry of physical exam findings, is used to illustrates the potential advantages of this approach.

  11. Venus gravity anomalies and their correlations with topography

    NASA Technical Reports Server (NTRS)

    Sjogren, W. L.; Bills, B. G.; Birkeland, P. W.; Esposito, P. B.; Konopliv, A. R.; Mottinger, N. A.; Ritke, S. J.; Phillips, R. J.

    1983-01-01

    This report provides a summary of the high-resolution gravity data obtained from the Pioneer Venus Orbiter radio tracking data. Gravity maps, covering a 70 deg latitude band through 360 deg of longitude, are displayed as line-of-sight and vertical gravity. Topography converted to gravity and Bouguer gravity maps are also shown in both systems. Topography to gravity ratios are made over several regions of the planet. There are markedly different ratios for the Aphrodite area as compared to the Beta and Atla areas.

  12. Multiresolution wavelet analysis for efficient analysis, compression and remote display of long-term physiological signals.

    PubMed

    Khuan, L Y; Bister, M; Blanchfield, P; Salleh, Y M; Ali, R A; Chan, T H

    2006-06-01

    Increased inter-equipment connectivity coupled with advances in Web technology allows ever escalating amounts of physiological data to be produced, far too much to be displayed adequately on a single computer screen. The consequence is that large quantities of insignificant data will be transmitted and reviewed. This carries an increased risk of overlooking vitally important transients. This paper describes a technique to provide an integrated solution based on a single algorithm for the efficient analysis, compression and remote display of long-term physiological signals with infrequent short duration, yet vital events, to effect a reduction in data transmission and display cluttering and to facilitate reliable data interpretation. The algorithm analyses data at the server end and flags significant events. It produces a compressed version of the signal at a lower resolution that can be satisfactorily viewed in a single screen width. This reduced set of data is initially transmitted together with a set of 'flags' indicating where significant events occur. Subsequent transmissions need only involve transmission of flagged data segments of interest at the required resolution. Efficient processing and code protection with decomposition alone is novel. The fixed transmission length method ensures clutter-less display, irrespective of the data length. The flagging of annotated events in arterial oxygen saturation, electroencephalogram and electrocardiogram illustrates the generic property of the algorithm. Data reduction of 87% to 99% and improved displays are demonstrated.

  13. Kinetic and dynamic kinetic resolution of secondary alcohols with ionic-surfactant-coated Burkholderia cepacia lipase: substrate scope and enantioselectivity.

    PubMed

    Kim, Cheolwoo; Lee, Jusuk; Cho, Jeonghun; Oh, Yeonock; Choi, Yoon Kyung; Choi, Eunjeong; Park, Jaiwook; Kim, Mahn-Joo

    2013-03-15

    Forty-four different secondary alcohols, which can be classified into several types (II-IX), were tested as the substrates of ionic surfactant-coated Burkholderia cepacia lipase (ISCBCL) to see its substrate scope and enantioselectivity in kinetic and dynamic kinetic resolution (KR and DKR). They include 6 boron-containing alcohols, 24 chiral propargyl alcohols, and 14 diarylmethanols. The results from the studies on KR indicate that ISCBCL accepted most of them with high enantioselectivity at ambient temperature and with useful to high enantioselectivity at elevated temperatures. In particular, ISCBCL displayed high enantioselectivity toward sterically demanding secondary alcohols (types VIII and IX) which have two bulky substituents at the hydroxymethine center. DKR reactions were performed by the combination of ISCBCL with a ruthenium-based racemization catalyst at 25-60 °C. Forty-one secondary alcohols were tested for DKR. About half of them were transformed into their acetates of high enantiopurity (>90% ee) with good yields (>80%). It is concluded that ISCBCL appears to be a superb enzyme for the KR and DKR of secondary alcohols.

  14. Projection-type see-through holographic three-dimensional display

    NASA Astrophysics Data System (ADS)

    Wakunami, Koki; Hsieh, Po-Yuan; Oi, Ryutaro; Senoh, Takanori; Sasaki, Hisayuki; Ichihashi, Yasuyuki; Okui, Makoto; Huang, Yi-Pai; Yamamoto, Kenji

    2016-10-01

    Owing to the limited spatio-temporal resolution of display devices, dynamic holographic three-dimensional displays suffer from a critical trade-off between the display size and the visual angle. Here we show a projection-type holographic three-dimensional display, in which a digitally designed holographic optical element and a digital holographic projection technique are combined to increase both factors at the same time. In the experiment, the enlarged holographic image, which is twice as large as the original display device, projected on the screen of the digitally designed holographic optical element was concentrated at the target observation area so as to increase the visual angle, which is six times as large as that for a general holographic display. Because the display size and the visual angle can be designed independently, the proposed system will accelerate the adoption of holographic three-dimensional displays in industrial applications, such as digital signage, in-car head-up displays, smart-glasses and head-mounted displays.

  15. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction withmore » specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L{sub amb}) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m{sup 2}, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u{sup '},v{sup '} color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.« less

  16. A Depth-Based Head-Mounted Visual Display to Aid Navigation in Partially Sighted Individuals

    PubMed Central

    Hicks, Stephen L.; Wilson, Iain; Muhammed, Louwai; Worsfold, John; Downes, Susan M.; Kennard, Christopher

    2013-01-01

    Independent navigation for blind individuals can be extremely difficult due to the inability to recognise and avoid obstacles. Assistive techniques such as white canes, guide dogs, and sensory substitution provide a degree of situational awareness by relying on touch or hearing but as yet there are no techniques that attempt to make use of any residual vision that the individual is likely to retain. Residual vision can restricted to the awareness of the orientation of a light source, and hence any information presented on a wearable display would have to limited and unambiguous. For improved situational awareness, i.e. for the detection of obstacles, displaying the size and position of nearby objects, rather than including finer surface details may be sufficient. To test whether a depth-based display could be used to navigate a small obstacle course, we built a real-time head-mounted display with a depth camera and software to detect the distance to nearby objects. Distance was represented as brightness on a low-resolution display positioned close to the eyes without the benefit focussing optics. A set of sighted participants were monitored as they learned to use this display to navigate the course. All were able to do so, and time and velocity rapidly improved with practise with no increase in the number of collisions. In a second experiment a cohort of severely sight-impaired individuals of varying aetiologies performed a search task using a similar low-resolution head-mounted display. The majority of participants were able to use the display to respond to objects in their central and peripheral fields at a similar rate to sighted controls. We conclude that the skill to use a depth-based display for obstacle avoidance can be rapidly acquired and the simplified nature of the display may appropriate for the development of an aid for sight-impaired individuals. PMID:23844067

  17. High End Visualization of Geophysical Datasets Using Immersive Technology: The SIO Visualization Center.

    NASA Astrophysics Data System (ADS)

    Newman, R. L.

    2002-12-01

    How many images can you display at one time with Power Point without getting "postage stamps"? Do you have fantastic datasets that you cannot view because your computer is too slow/small? Do you assume a few 2-D images of a 3-D picture are sufficient? High-end visualization centers can minimize and often eliminate these problems. The new visualization center [http://siovizcenter.ucsd.edu] at Scripps Institution of Oceanography [SIO] immerses users into a virtual world by projecting 3-D images onto a Panoram GVR-120E wall-sized floor-to-ceiling curved screen [7' x 23'] that has 3.2 mega-pixels of resolution. The Infinite Reality graphics subsystem is driven by a single-pipe SGI Onyx 3400 with a system bandwidth of 44 Gbps. The Onyx is powered by 16 MIPS R12K processors and 16 GB of addressable memory. The system is also equipped with transmitters and LCD shutter glasses which permit stereographic 3-D viewing of high-resolution images. This center is ideal for groups of up to 60 people who can simultaneously view these large-format images. A wide range of hardware and software is available, giving the users a totally immersive working environment in which to display, analyze, and discuss large datasets. The system enables simultaneous display of video and audio streams from sources such as SGI megadesktop and stereo megadesktop, S-VHS video, DVD video, and video from a Macintosh or PC. For instance, one-third of the screen might be displaying S-VHS video from a remotely-operated-vehicle [ROV], while the remaining portion of the screen might be used for an interactive 3-D flight over the same parcel of seafloor. The video and audio combinations using this system are numerous, allowing users to combine and explore data and images in innovative ways, greatly enhancing scientists' ability to visualize, understand and collaborate on complex datasets. In the not-distant future, with the rapid growth in networking speeds in the US, it will be possible for Earth Sciences Departments to collaborate effectively while limiting the amount of physical travel required. This includes porting visualization content to the popular, low-cost Geowall visualization systems, and providing web-based access to databanks filled with stock geoscience visualizations.

  18. Design and characterization of an ultraresolution seamlessly tiled display for data visualization

    NASA Astrophysics Data System (ADS)

    Bordes, Nicole; Bleha, William P.; Pailthorpe, Bernard

    2003-09-01

    The demand for more pixels in digital displays is beginning to be met as manufacturers increase the native resolution of projector chips. Tiling several projectors still offers one solution to augment the pixel capacity of a display. However problems of color and illumination uniformity across projectors need to be addressed as well as the computer software required to drive such devices. In this paper we present the results obtained on a desktop size tiled projector array of three D-ILA projectors sharing a common illumination source. The composite image on a 3 x 1 array, is 3840 by 1024 pixels with a resolution of about 80 dpi. The system preserves desktop resolution, is compact and can fit in a normal room or laboratory. A fiber optic beam splitting system and a single set of red, green and blue dichroic filters are the key to color and illumination uniformity. The D-ILA chips inside each projector can be adjusted individually to set or change characteristics such as contrast, brightness or gamma curves. The projectors were matched carefully and photometric variations were corrected, leading to a seamless tiled image. Photometric measurements were performed to characterize the display and losses through the optical paths, and are reported here. This system is driven by a small PC computer cluster fitted with graphics cards and is running Linux. The Chromium API can be used for tiling graphics tiles across the display and interfacing to users' software applications. There is potential for scaling the design to accommodate larger arrays, up to 4x5 projectors, increasing display system capacity to 50 Megapixels. Further increases, beyond 100 Megapixels can be anticipated with new generation D-ILA chips capable of projecting QXGA (2k x 1.5k), with ongoing evolution as QUXGA (4k x 2k) becomes available.

  19. Tile-Image Merging and Delivering for Virtual Camera Services on Tiled-Display for Real-Time Remote Collaboration

    NASA Astrophysics Data System (ADS)

    Choe, Giseok; Nang, Jongho

    The tiled-display system has been used as a Computer Supported Cooperative Work (CSCW) environment, in which multiple local (and/or remote) participants cooperate using some shared applications whose outputs are displayed on a large-scale and high-resolution tiled-display, which is controlled by a cluster of PC's, one PC per display. In order to make the collaboration effective, each remote participant should be aware of all CSCW activities on the titled display system in real-time. This paper presents a capturing and delivering mechanism of all activities on titled-display system to remote participants in real-time. In the proposed mechanism, the screen images of all PC's are periodically captured and delivered to the Merging Server that maintains separate buffers to store the captured images from the PCs. The mechanism selects one tile image from each buffer, merges the images to make a screen shot of the whole tiled-display, clips a Region of Interest (ROI), compresses and streams it to remote participants in real-time. A technical challenge in the proposed mechanism is how to select a set of tile images, one from each buffer, for merging so that the tile images displayed at the same time on the tiled-display can be properly merged together. This paper presents three selection algorithms; a sequential selection algorithm, a capturing time based algorithm, and a capturing time and visual consistency based algorithm. It also proposes a mechanism of providing several virtual cameras on tiled-display system to remote participants by concurrently clipping several different ROI's from the same merged tiled-display images, and delivering them after compressing with video encoders requested by the remote participants. By interactively changing and resizing his/her own ROI, a remote participant can check the activities on the tiled-display effectively. Experiments on a 3 × 2 tiled-display system show that the proposed merging algorithm can build a tiled-display image stream synchronously, and the ROI-based clipping and delivering mechanism can provide individual views on the tiled-display system to multiple remote participants in real-time.

  20. Studies of the field-of-view resolution tradeoff in virtual-reality systems

    NASA Technical Reports Server (NTRS)

    Piantanida, Thomas P.; Boman, Duane; Larimer, James; Gille, Jennifer; Reed, Charles

    1992-01-01

    Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.

  1. Physical evaluation of color and monochrome medical displays using an imaging colorimeter

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2013-03-01

    This paper presents an approach to physical evaluation of color and monochrome medical grade displays using an imaging colorimeter. The purpose of this study was to examine the influence of medical display types, monochrome or color at the same maximum luminance settings, on diagnostic performance. The focus was on the measurements of physical characteristics including spatial resolution and noise performance, which we believed could affect the clinical performance. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between two EIZO displays.

  2. Tele-transmission of stereoscopic images of the optic nerve head in glaucoma via Internet.

    PubMed

    Bergua, Antonio; Mardin, Christian Y; Horn, Folkert K

    2009-06-01

    The objective was to describe an inexpensive system to visualize stereoscopic photographs of the optic nerve head on computer displays and to transmit such images via the Internet for collaborative research or remote clinical diagnosis in glaucoma. Stereoscopic images of glaucoma patients were digitized and stored in a file format (joint photographic stereoimage [jps]) containing all three-dimensional information for both eyes on an Internet Web site (www.trizax.com). The size of jps files was between 0.4 to 1.4 MB (corresponding to a diagonal stereo image size between 900 and 1400 pixels) suitable for Internet protocols. A conventional personal computer system equipped with wireless stereoscopic LCD shutter glasses and a CRT-monitor with high refresh rate (120 Hz) can be used to obtain flicker-free stereo visualization of true-color images with high resolution. Modern thin-film transistor-LCD displays in combination with inexpensive red-cyan goggles achieve stereoscopic visualization with the same resolution but reduced color quality and contrast. The primary aim of our study was met to transmit stereoscopic images via the Internet. Additionally, we found that with both stereoscopic visualization techniques, cup depth, neuroretinal rim shape, and slope of the inner wall of the optic nerve head, can be qualitatively better perceived and interpreted than with monoscopic images. This study demonstrates high-quality and low-cost Internet transmission of stereoscopic images of the optic nerve head from glaucoma patients. The technique allows exchange of stereoscopic images and can be applied to tele-diagnostic and glaucoma research.

  3. A CMOS microdisplay with integrated controller utilizing improved silicon hot carrier luminescent light sources

    NASA Astrophysics Data System (ADS)

    Venter, Petrus J.; Alberts, Antonie C.; du Plessis, Monuko; Joubert, Trudi-Heleen; Goosen, Marius E.; Janse van Rensburg, Christo; Rademeyer, Pieter; Fauré, Nicolaas M.

    2013-03-01

    Microdisplay technology, the miniaturization and integration of small displays for various applications, is predominantly based on OLED and LCoS technologies. Silicon light emission from hot carrier electroluminescence has been shown to emit light visibly perceptible without the aid of any additional intensification, although the electrical to optical conversion efficiency is not as high as the technologies mentioned above. For some applications, this drawback may be traded off against the major cost advantage and superior integration opportunities offered by CMOS microdisplays using integrated silicon light sources. This work introduces an improved version of our previously published microdisplay by making use of new efficiency enhanced CMOS light emitting structures and an increased display resolution. Silicon hot carrier luminescence is often created when reverse biased pn-junctions enter the breakdown regime where impact ionization results in carrier transport across the junction. Avalanche breakdown is typically unwanted in modern CMOS processes. Design rules and process design are generally tailored to prevent breakdown, while the voltages associated with breakdown are too high to directly interact with the rest of the CMOS standard library. This work shows that it is possible to lower the operating voltage of CMOS light sources without compromising the optical output power. This results in more efficient light sources with improved interaction with other standard library components. This work proves that it is possible to create a reasonably high resolution microdisplay while integrating the active matrix controller and drivers on the same integrated circuit die without additional modifications, in a standard CMOS process.

  4. Characterization of conductive nanobiomaterials derived from viral assemblies by low-voltage STEM imaging and Raman scattering

    NASA Astrophysics Data System (ADS)

    Plascencia-Villa, Germán; Carreño-Fuentes, Liliana; Bahena, Daniel; José-Yacamán, Miguel; Palomares, Laura A.; Ramírez, Octavio T.

    2014-09-01

    New technologies require the development of novel nanomaterials that need to be fully characterized to achieve their potential. High-resolution low-voltage scanning transmission electron microscopy (STEM) has proven to be a very powerful technique in nanotechnology, but its use for the characterization of nanobiomaterials has been limited. Rotavirus VP6 self-assembles into nanotubular assemblies that possess an intrinsic affinity for Au ions. This property was exploited to produce hybrid nanobiomaterials by the in situ functionalization of recombinant VP6 nanotubes with gold nanoparticles. In this work, Raman spectroscopy and advanced analytical electron microscopy imaging with spherical aberration-corrected (Cs) STEM and nanodiffraction at low-voltage doses were employed to characterize nanobiomaterials. STEM imaging revealed the precise structure and arrangement of the protein templates, as well as the nanostructure and atomic arrangement of gold nanoparticles with high spatial sub-Angstrom resolution and avoided radiation damage. The imaging was coupled with backscattered electron imaging, ultra-high resolution scanning electron microscopy and x-ray spectroscopy. The hybrid nanobiomaterials that were obtained showed unique properties as bioelectronic conductive devices and showed enhanced Raman scattering by their precise arrangement into superlattices, displaying the utility of viral assemblies as functional integrative self-assembled nanomaterials for novel applications.

  5. Apolipoprotein AI tertiary structures determine stability and phospholipid-binding activity of discoidal high-density lipoprotein particles of different sizes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Bin; Ren, Xuefeng; Neville, Tracey

    2009-05-18

    Human high-density lipoprotein (HDL) plays a key role in the reverse cholesterol transport pathway that delivers excess cholesterol back to the liver for clearance. In vivo, HDL particles vary in size, shape and biological function. The discoidal HDL is a 140-240 kDa, disk-shaped intermediate of mature HDL. During mature spherical HDL formation, discoidal HDLs play a key role in loading cholesterol ester onto the HDL particles by activating the enzyme, lecithin:cholesterol acyltransferase (LCAT). One of the major problems for high-resolution structural studies of discoidal HDL is the difficulty in obtaining pure and, foremost, homogenous sample. We demonstrate here that themore » commonly used cholate dialysis method for discoidal HDL preparation usually contains 5-10% lipid-poor apoAI that significantly interferes with the high-resolution structural analysis of discoidal HDL using biophysical methods. Using an ultracentrifugation method, we quickly removed lipid-poor apoAI. We also purified discoidal reconstituted HDL (rHDL) into two pure discoidal HDL species of different sizes that are amendable for high-resolution structural studies. A small rHDL has a diameter of 7.6 nm, and a large rHDL has a diameter of 9.8 nm. We show that these two different sizes of discoidal HDL particles display different stability and phospholipid-binding activity. Interestingly, these property/functional differences are independent from the apoAI -helical secondary structure, but are determined by the tertiary structural difference of apoAI on different discoidal rHDL particles, as evidenced by two-dimensional NMR and negative stain electron microscopy data. Our result further provides the first high-resolution NMR data, demonstrating a promise of structural determination of discoidal HDL at atomic resolution using a combination of NMR and other biophysical techniques.« less

  6. The OCT penlight: in-situ image guidance for microsurgery

    NASA Astrophysics Data System (ADS)

    Galeotti, John; Sajjad, Areej; Wang, Bo; Kagemann, Larry; Shukla, Gaurav; Siegel, Mel; Wu, Bing; Klatzky, Roberta; Wollstein, Gadi; Schuman, Joel S.; Stetten, George

    2010-02-01

    We have developed a new image-based guidance system for microsurgery using optical coherence tomography (OCT), which presents a virtual image in its correct location inside the scanned tissue. Applications include surgery of the cornea, skin, and other surfaces below which shallow targets may advantageously be displayed for the naked eye or low-power magnification by a surgical microscope or loupes (magnifying eyewear). OCT provides real-time highresolution (3 micron) images at video rates within a two or more millimeter axial range in soft tissue, and is therefore suitable for guidance to various shallow targets such as Schlemm's canal in the eye (for treating Glaucoma) or skin tumors. A series of prototypes of the "OCT penlight" have produced virtual images with sufficient resolution and intensity to be useful under magnification, while the geometrical arrangement between the OCT scanner and display optics (including a half-silvered mirror) permits sufficient surgical access. The two prototypes constructed thus far have used, respectively, a miniature organic light emitting diode (OLED) display and a reflective liquid crystal on silicon (LCoS) display. The OLED has the advantage of relative simplicity, satisfactory resolution (15 micron), and color capability, whereas the LCoS can produce an image with much higher intensity and superior resolution (12 micron), although it is monochromatic and more complicated optically. Intensity is a crucial limiting factor, since light flux is greatly diminished with increasing magnification, thus favoring the LCoS as the more practical system.

  7. Prospects of high-resolution resonant X-ray inelastic scattering studies on solid materials, liquids and gases at diffraction-limited storage rings

    PubMed Central

    Schmitt, Thorsten; de Groot, Frank M. F.; Rubensson, Jan-Erik

    2014-01-01

    The spectroscopic technique of resonant inelastic X-ray scattering (RIXS) will particularly profit from immensely improved brilliance of diffraction-limited storage rings (DLSRs). In RIXS one measures the intensities of excitations as a function of energy and momentum transfer. DLSRs will allow for pushing the achievable energy resolution, signal intensity and the sampled spot size to new limits. With RIXS one nowadays probes a broad range of electronic systems reaching from simple molecules to complex materials displaying phenomena like peculiar magnetism, two-dimensional electron gases, superconductivity, photovoltaic energy conversion and heterogeneous catalysis. In this article the types of improved RIXS studies that will become possible with X-ray beams from DLSRs are envisioned. PMID:25177995

  8. Early views of the martian surface from the Mars Orbiter Camera of Mars Global Surveyor.

    PubMed

    Malin, M C; Carr, M H; Danielson, G E; Davies, M E; Hartmann, W K; Ingersoll, A P; James, P B; Masursky, H; McEwen, A S; Soderblom, L A; Thomas, P; Veverka, J; Caplinger, M A; Ravine, M A; Soulanille, T A; Warren, J L

    1998-03-13

    High-resolution images of the martian surface at scales of a few meters show ubiquitous erosional and depositional eolian landforms. Dunes, sandsheets, and drifts are prevalent and exhibit a range of morphology, composition (inferred from albedo), and age (as seen in occurrences of different dune orientations at the same location). Steep walls of topographic depressions such as canyons, valleys, and impact craters show the martian crust to be stratified at scales of a few tens of meters. The south polar layered terrain and superposed permanent ice cap display diverse surface textures that may reflect the complex interplay of volatile and non-volatile components. Low resolution regional views of the planet provide synoptic observations of polar cap retreat, condensate clouds, and the lifecycle of local and regional dust storms.

  9. A CAMAC display module for fast bit-mapped graphics

    NASA Astrophysics Data System (ADS)

    Abdel-Aal, R. E.

    1992-10-01

    In many data acquisition and analysis facilities for nuclear physics research, utilities for the display of two-dimensional (2D) images and spectra on graphics terminals suffer from low speed, poor resolution, and limited accuracy. Development of CAMAC bit-mapped graphics modules for this purpose has been discouraged in the past by the large device count needed and the long times required to load the image data from the host computer into the CAMAC hardware; particularly since many such facilities have been designed to support fast DMA block transfers only for data acquisition into the host. This paper describes the design and implementation of a prototype CAMAC graphics display module with a resolution of 256×256 pixels at eight colours for which all components can be easily accommodated in a single-width package. Employed is a hardware technique which reduces the number of programmed CAMAC data transfer operations needed for writing 2D images into the display memory by approximately an order of magnitude, with attendant improvements in the display speed and CPU time consumption. Hardware and software details are given together with sample results. Information on the performance of the module in a typical VAX/MBD data acquisition environment is presented, including data on the mutual effects of simultaneous data acquisition traffic. Suggestions are made for further improvements in performance.

  10. Calculation comparison of an additive and subtractive light modulator for high-resolution pixellight headlamps

    NASA Astrophysics Data System (ADS)

    Held, Marcel Philipp; Ley, Peer-Phillip; Lachmayer, Roland

    2018-02-01

    High-resolution vehicle headlamps represent a future-oriented technology that increases traffic safety and driving comfort in the dark. A further development to current matrix beam headlamps are LED-based pixellight systems which enable additional lighting functions (e.g. the projection of navigation information on the road) to be activated for given driving scenarios. The image generation is based on spatial light modulators (SLM) such as digital micromirror devices (DMD), liquid crystal displays (LCD), liquid crystal on silicon (LCoS) devices or LED arrays. For DMD-, LCD- and LCoSbased headlamps, the optical system uses illumining optics to ensure a precise illumination of the corresponding SLM. LED arrays, however, have to use imaging optics to project the LED die onto an intermediate image plane and thus create the light distribution via an apposition of gapless juxtapositional LED die images. Nevertheless, the lambertian radiation characteristics complex the design of imaging optics regarding a highefficiency setup with maximum resolution and luminous flux. Simplifying the light source model and its emitting characteristics allows to determine a balanced setup between these parameters by using the Etendue and to ´ calculate the maximum possible efficacy and luminous flux for each technology in an early designing stage. Therefore, we present a calculation comparison of how simplifying the light source model can affect the Etendue ´ conservation and the setup design for two high-resolution technologies. The shown approach is evaluated and compared to simulation models to show the occurring deviation and its applicability.

  11. High spatial resolution imaging for structural health monitoring based on virtual time reversal

    NASA Astrophysics Data System (ADS)

    Cai, Jian; Shi, Lihua; Yuan, Shenfang; Shao, Zhixue

    2011-05-01

    Lamb waves are widely used in structural health monitoring (SHM) of plate-like structures. Due to the dispersion effect, Lamb wavepackets will be elongated and the resolution for damage identification will be strongly affected. This effect can be automatically compensated by the time reversal process (TRP). However, the time information of the compensated waves is also removed at the same time. To improve the spatial resolution of Lamb wave detection, virtual time reversal (VTR) is presented in this paper. In VTR, a changing-element excitation and reception mechanism (CERM) rather than the traditional fixed excitation and reception mechanism (FERM) is adopted for time information conservation. Furthermore, the complicated TRP procedure is replaced by simple signal operations which can make savings in the hardware cost for recording and generating the time-reversed Lamb waves. After the effects of VTR for dispersive damage scattered signals are theoretically analyzed, the realization of VTR involving the acquisition of the transfer functions of damage detecting paths under step pulse excitation is discussed. Then, a VTR-based imaging method is developed to improve the spatial resolution of the delay-and-sum imaging with a sparse piezoelectric (PZT) wafer array. Experimental validation indicates that the damage scattered wavepackets of A0 mode in an aluminum plate are partly recompressed and focalized with their time information preserved by VTR. Both the single damage and the dual adjacent damages in the plate can be clearly displayed with high spatial resolution by the proposed VTR-based imaging method.

  12. Human-centered design for neonatal apnea monitoring: application of the UFuRT process to analyze a monitor display layout.

    PubMed

    Brannon, Timothy S

    2008-11-06

    Resolution of apnea of prematurity is a criterion for hospital discharge of the preterm infant. False alarms recorded as true events can prolong hospitalization and increase cost of care. The UFuRT process was used to analyze neonatal apnea monitoring, using a typical monitor display. The goals were to determine 1) the data needed to recognize true events and reject false alarms, and 2) how the display layout could be modified to better support these tasks.

  13. Human Engineer’s Guide to Auditory Displays. Volume 2. Elements of Signal Reception and Resolution Affecting Auditory Displays.

    DTIC Science & Technology

    1984-08-01

    90de It noce..etrv wnd identify by block numberl .’-- This work reviews the areas of monaural and binaural signal detection, auditory discrimination And...AUDITORY DISPLAYS This work reviews the areas of monaural and binaural signal detection, auditory discrimination and localization, and reaction times to...pertaining to the major areas of auditory processing in humans. The areas covered in the reviews presented here are monaural and binaural siqnal detection

  14. Optical micro-profilometry for archaeology

    NASA Astrophysics Data System (ADS)

    Carcagni, Pierluigi; Daffara, Claudia; Fontana, Raffaella; Gambino, Maria Chiara; Mastroianni, Maria; Mazzotta, Cinazia; Pampaloni, Enrico; Pezzati, Luca

    2005-06-01

    A quantitative morphological analysis of archaeological objects represents an important element for historical evaluations, artistic studies and conservation projects. At present, a variety of contact instruments for high-resolution surface survey is available on the market, but because of their invasivity they are not well received in the field of artwork conservation. On the contrary, optical testing techniques have seen a successful growth in last few years due to their effectiveness and safety. In this work we present a few examples of application of high-resolution 3D techniques for the survey of archaeological objects. Measurements were carried out by means of an optical micro-profilometer composed of a commercial conoprobe mounted on a scanning device that allows a maximum sampled area of 280×280 mm2. Measurements as well as roughness calculations were carried out on selected areas, representative of the differently degraded surface, of an ellenestic bronze statue to document the surface corrosion before restoration intervention started. Two highly-corroded ancient coins and a limestone column were surveyed to enhance the relief of inscriptions and drawings for dating purposes. High-resolution 3D survey, beyond the faithful representation of objects, makes it possible to display the surface in an image format that can be processed by means of image processing software. The application of digital filters as well as rendering techniques easies the readability of the smallest details.

  15. Research on the underwater target imaging based on the streak tube laser lidar

    NASA Astrophysics Data System (ADS)

    Cui, Zihao; Tian, Zhaoshuo; Zhang, Yanchao; Bi, Zongjie; Yang, Gang; Gu, Erdan

    2018-03-01

    A high frame rate streak tube imaging lidar (STIL) for real-time 3D imaging of underwater targets is presented in this paper. The system uses 532nm pulse laser as the light source, the maximum repetition rate is 120Hz, and the pulse width is 8ns. LabVIEW platform is used in the system, the system control, synchronous image acquisition, 3D data processing and display are realized through PC. 3D imaging experiment of underwater target is carried out in a flume with attenuation coefficient of 0.2, and the images of different depth and different material targets are obtained, the imaging frame rate is 100Hz, and the maximum detection depth is 31m. For an underwater target with a distance of 22m, the high resolution 3D image real-time acquisition is realized with range resolution of 1cm and space resolution of 0.3cm, the spatial relationship of the targets can be clearly identified by the image. The experimental results show that STIL has a good application prospect in underwater terrain detection, underwater search and rescue, and other fields.

  16. BiI 3 Crystals for High Energy Resolution Gamma-Ray Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nino, Juan C.; Baciak, James; Johns, Paul

    2017-04-12

    BiI 3 had been investigated for its unique properties as a layered compound semiconductor for many decades. However, despite the exceptional atomic, physical, and electronic properties of this material, good resolution gamma ray spectra had never been reported for BiI 3. The shortcomings that previously prevented BiI 3 from reaching success as a gamma ray sensor were, through this project, identified and suppressed to unlock the performance of this promising compound. Included in this work were studies on a number of methods which have, for the first time, enabled BiI 3 to exhibit spectral performance rivaling many other candidate semiconductorsmore » for room temperature gamma ray sensors. New approaches to crystal growth were explored that allow BiI 3 spectrometers to be fabricated with up to 2.2% spectral resolution at 662 keV. Fundamental studies on trap states, dopant incorporation, and polarization were performed to enhance performance of this compound. Additionally, advanced detection techniques were applied to display the capabilities of high quality BiI 3 spectrometers. Overall, through this work, BiI 3 has been revealed as a potentially transformative material for nuclear security and radiation detection sciences.« less

  17. HUNTING THE PARENT OF THE ORPHAN STREAM: IDENTIFYING STREAM MEMBERS FROM LOW-RESOLUTION SPECTROSCOPY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casey, Andrew R.; Da Costa, Gary; Keller, Stefan C.

    2013-02-10

    We present candidate K-giant members in the Orphan Stream that have been identified from low-resolution data taken with the AAOmega spectrograph on the Anglo-Australian Telescope. From modest signal-to-noise spectra and independent cuts in photometry, kinematics, gravity, and metallicity we yield self-consistent, highly probable stream members. We find a revised stream distance of 22.5 {+-} 2.0 kpc near the celestial equator and our kinematic signature peaks at V {sub GSR} = 82.1 {+-} 1.4 km s{sup -1}. The observed velocity dispersion of our most probable members is consistent with arising from the velocity uncertainties alone. This indicates that at least alongmore » this line of sight, the Orphan Stream is kinematically cold. Our data indicate an overall stream metallicity of [Fe/H] = -1.63 {+-} 0.19 dex which is more metal-rich than previously found and unbiased by spectral type. Furthermore, the significant metallicity dispersion displayed by our most probable members, {sigma}([Fe/H]) = 0.56 dex, suggests that the unidentified Orphan Stream parent is a dSph satellite. We highlight likely members for high-resolution spectroscopic follow-up.« less

  18. Digital Camera Control for Faster Inspection

    NASA Technical Reports Server (NTRS)

    Brown, Katharine; Siekierski, James D.; Mangieri, Mark L.; Dekome, Kent; Cobarruvias, John; Piplani, Perry J.; Busa, Joel

    2009-01-01

    Digital Camera Control Software (DCCS) is a computer program for controlling a boom and a boom-mounted camera used to inspect the external surface of a space shuttle in orbit around the Earth. Running in a laptop computer in the space-shuttle crew cabin, DCCS commands integrated displays and controls. By means of a simple one-button command, a crewmember can view low- resolution images to quickly spot problem areas and can then cause a rapid transition to high- resolution images. The crewmember can command that camera settings apply to a specific small area of interest within the field of view of the camera so as to maximize image quality within that area. DCCS also provides critical high-resolution images to a ground screening team, which analyzes the images to assess damage (if any); in so doing, DCCS enables the team to clear initially suspect areas more quickly than would otherwise be possible and further saves time by minimizing the probability of re-imaging of areas already inspected. On the basis of experience with a previous version (2.0) of the software, the present version (3.0) incorporates a number of advanced imaging features that optimize crewmember capability and efficiency.

  19. Design and characterization of a handheld multimodal imaging device for the assessment of oral epithelial lesions

    NASA Astrophysics Data System (ADS)

    Higgins, Laura M.; Pierce, Mark C.

    2014-08-01

    A compact handpiece combining high resolution fluorescence (HRF) imaging with optical coherence tomography (OCT) was developed to provide real-time assessment of oral lesions. This multimodal imaging device simultaneously captures coregistered en face images with subcellular detail alongside cross-sectional images of tissue microstructure. The HRF imaging acquires a 712×594 μm2 field-of-view at the sample with a spatial resolution of 3.5 μm. The OCT images were acquired to a depth of 1.5 mm with axial and lateral resolutions of 9.3 and 8.0 μm, respectively. HRF and OCT images are simultaneously displayed at 25 fps. The handheld device was used to image a healthy volunteer, demonstrating the potential for in vivo assessment of the epithelial surface for dysplastic and neoplastic changes at the cellular level, while simultaneously evaluating submucosal involvement. We anticipate potential applications in real-time assessment of oral lesions for improved surveillance and surgical guidance.

  20. Topography of Venus and earth - A test for the presence of plate tectonics

    NASA Technical Reports Server (NTRS)

    Head, J. W.; Yuter, S. E.; Solomon, S. C.

    1981-01-01

    Comparisons of earth and Venus topography by use of Pioneer/Venus radar altimetry are examined. Approximately 93% of the Venus surface has been mapped with a horizontal resolution of 200 km and a vertical resolution of 200 m. Tectonic troughs have been indicated in plains regions which cover 65% of Venus, and hypsometric comparisons between the two planets' elevation distributions revealed that while the earth has a bimodal height distribution, Venus displays a unimodal configuration, with 60% of the planet surface within 500 m of the modal planet radius. The effects of mapping the earth at the same resolution as the Venus observations were explored. Continents and oceans were apparent, and although folded mountains appeared as high spots, no indications of tectonic activity were discernible. A NASA Venus Orbiting Imaging radar is outlined, which is designed to detect volcanoes, folded mountain ranges, craters, and faults, and thereby allow definition of possible plate-tectonic activity on Venus.

  1. Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.

    PubMed

    Wojtkowski, Maciej; Srinivasan, Vivek; Fujimoto, James G; Ko, Tony; Schuman, Joel S; Kowalczyk, Andrzej; Duker, Jay S

    2005-10-01

    To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain detection enables dramatic increases in imaging speeds. Three-dimensional OCT retinal imaging is performed in normal human subjects using high-speed ultrahigh-resolution OCT. Three-dimensional OCT data of the macula and optic disc are acquired using a dense raster scan pattern. New processing and display methods for generating virtual OCT fundus images; cross-sectional OCT images with arbitrary orientations; quantitative maps of retinal, nerve fiber layer, and other intraretinal layer thicknesses; and optic nerve head topographic parameters are demonstrated. Three-dimensional OCT imaging enables new imaging protocols that improve visualization and mapping of retinal microstructure. An OCT fundus image can be generated directly from the 3D OCT data, which enables precise and repeatable registration of cross-sectional OCT images and thickness maps with fundus features. Optical coherence tomography images with arbitrary orientations, such as circumpapillary scans, can be generated from 3D OCT data. Mapping of total retinal thickness and thicknesses of the nerve fiber layer, photoreceptor layer, and other intraretinal layers is demonstrated. Measurement of optic nerve head topography and disc parameters is also possible. Three-dimensional OCT enables measurements that are similar to those of standard instruments, including the StratusOCT, GDx, HRT, and RTA. Three-dimensional OCT imaging can be performed using high-speed ultrahigh-resolution OCT. Three-dimensional OCT provides comprehensive visualization and mapping of retinal microstructures. The high data acquisition speeds enable high-density data sets with large numbers of transverse positions on the retina, which reduces the possibility of missing focal pathologies. In addition to providing image information such as OCT cross-sectional images, OCT fundus images, and 3D rendering, quantitative measurement and mapping of intraretinal layer thickness and topographic features of the optic disc are possible. We hope that 3D OCT imaging may help to elucidate the structural changes associated with retinal disease as well as improve early diagnosis and monitoring of disease progression and response to treatment.

  2. Synthesis and electronic properties of nanophase semiconductor materials

    NASA Astrophysics Data System (ADS)

    Sailor, Michael J.

    1993-05-01

    The objective of the research effort is to understand and learn to control the morphologic and electronic properties of electrodeposited nanophase semiconductors. The initial work has focused on electrodeposition of nanophase CdSe, using a sequential monolayer deposition technique that we are developing. We are currently extending the synthesis phase of this project into silicon, silicon carbide, and phosphor materials. This work also encompasses studying semiconductor electrodeposition into materials with restricted dimensions, such as microporous alumina and porous silicon membranes. By growing films with very small grain sizes, we hope to produce and study materials that display unusual electronic or luminescent effects. We are primarily interested in the electronic properties of the II-VI and group IV materials, for potential applications in nanoscale electronics and optical detector technologies. The phosphors are being studied for their potential as efficient high-resolution display materials.

  3. An HTML Tool for Production of Interactive Stereoscopic Compositions.

    PubMed

    Chistyakov, Alexey; Soto, Maria Teresa; Martí, Enric; Carrabina, Jordi

    2016-12-01

    The benefits of stereoscopic vision in medical applications were appreciated and have been thoroughly studied for more than a century. The usage of the stereoscopic displays has a proven positive impact on performance in various medical tasks. At the same time the market of 3D-enabled technologies is blooming. New high resolution stereo cameras, TVs, projectors, monitors, and head mounted displays become available. This equipment, completed with a corresponding application program interface (API), could be relatively easy implemented in a system. Such complexes could open new possibilities for medical applications exploiting the stereoscopic depth. This work proposes a tool for production of interactive stereoscopic graphical user interfaces, which could represent a software layer for web-based medical systems facilitating the stereoscopic effect. Further the tool's operation mode and the results of the conducted subjective and objective performance tests will be exposed.

  4. Radiologists' confidence in detecting abnormalities on chest images and their subjective judgments of image quality

    NASA Astrophysics Data System (ADS)

    King, Jill L.; Gur, David; Rockette, Howard E.; Curtin, Hugh D.; Obuchowski, Nancy A.; Thaete, F. Leland; Britton, Cynthia A.; Metz, Charles E.

    1991-07-01

    The relationship between subjective judgments of image quality for the performance of specific detection tasks and radiologists' confidence level in arriving at correct diagnoses was investigated in two studies in which 12 readers, using a total of three different display environments, interpreted a series of 300 PA chest images. The modalities used were conventional films, laser-printed films, and high-resolution CRT display of digitized images. For the detection of interstitial disease, nodules, and pneumothoraces, there was no statistically significant correlation (Spearman rho) between subjective ratings of quality and radiologists' confidence in detecting these abnormalities. However, in each study, for all modalities and all readers but one, a small but statistically significant correlation was found between the radiologists' ability to correctly and confidently rule out interstitial disease and their subjective ratings of image quality.

  5. An atlas of monthly mean distributions of SSMI surface wind speed, ARGOS buoy drift, AVHRR/2 sea surface temperature, and ECMWF surface wind components during 1990

    NASA Technical Reports Server (NTRS)

    Halpern, D.; Knauss, W.; Brown, O.; Wentz, F.

    1993-01-01

    The following monthly mean global distributions for 1990 are proposed with a common color scale and geographical map: 10-m height wind speed estimated from the Special Sensor Microwave Imager (SSMI) on a United States (US) Air Force Defense Meteorological Satellite Program (DMSP) spacecraft; sea surface temperature estimated from the advanced very high resolution radiometer (AVHRR/2) on a U.S. National Oceanic and Atmospheric Administration (NOAA) spacecraft; Cartesian components of free drifting buoys which are tracked by the ARGOS navigation system on NOAA satellites; and Cartesian components on the 10-m height wind vector computed by the European Center for Medium-Range Weather Forecasting (ECMWF). Charts of monthly mean value, sampling distribution, and standard deviation values are displayed. Annual mean distributions are displayed.

  6. An atlas of monthly mean distributions of SSMI surface wind speed, ARGOS buoy drift, AVHRR/2 sea surface temperature, and ECMWF surface wind components during 1991

    NASA Technical Reports Server (NTRS)

    Halpern, D.; Knauss, W.; Brown, O.; Wentz, F.

    1993-01-01

    The following monthly mean global distributions for 1991 are presented with a common color scale and geographical map: 10-m height wind speed estimated from the Special Sensor Microwave Imager (SSMI) on a United States Air Force Defense Meteorological Satellite Program (DMSP) spacecraft; sea surface temperature estimated from the advanced very high resolution radiometer (AVHRR/2) on a U.S. National Oceanic and Atmospheric Administration (NOAA) spacecraft; Cartesian components of free-drifting buoys which are tracked by the ARGOS navigation system on NOAA satellites; and Cartesian components of the 10-m height wind vector computed by the European Center for Medium-Range Weather Forecasting (ECMWF). Charts of monthly mean value, sampling distribution, and standard deviation value are displayed. Annual mean distributions are displayed.

  7. Fiber Optic Communication System For Medical Images

    NASA Astrophysics Data System (ADS)

    Arenson, Ronald L.; Morton, Dan E.; London, Jack W.

    1982-01-01

    This paper discusses a fiber optic communication system linking ultrasound devices, Computerized tomography scanners, Nuclear Medicine computer system, and a digital fluoro-graphic system to a central radiology research computer. These centrally archived images are available for near instantaneous recall at various display consoles. When a suitable laser optical disk is available for mass storage, more extensive image archiving will be added to the network including digitized images of standard radiographs for comparison purposes and for remote display in such areas as the intensive care units, the operating room, and selected outpatient departments. This fiber optic system allows for a transfer of high resolution images in less than a second over distances exceeding 2,000 feet. The advantages of using fiber optic cables instead of typical parallel or serial communication techniques will be described. The switching methodology and communication protocols will also be discussed.

  8. Intonation Facilitates Contrast Resolution: Evidence from Japanese Adults and 6-Year Olds

    ERIC Educational Resources Information Center

    Ito, Kiwako; Jincho, Nobuyuki; Minai, Utako; Yamane, Naoto; Mazuka, Reiko

    2012-01-01

    Two eye-tracking experiments tested how pitch prominence on a prenominal adjective affects contrast resolution in Japanese adult and 6-year old listeners. Participants located two animals in succession on displays with multiple colored animals. In Experiment 1, adults' fixations to the contrastive target (pink cat [right arrow] GREEN cat) were…

  9. Color Imaging management in film processing

    NASA Astrophysics Data System (ADS)

    Tremeau, Alain; Konik, Hubert; Colantoni, Philippe

    2003-12-01

    The latest research projects in the laboratory LIGIV concerns capture, processing, archiving and display of color images considering the trichromatic nature of the Human Vision System (HSV). Among these projects one addresses digital cinematographic film sequences of high resolution and dynamic range. This project aims to optimize the use of content for the post-production operators and for the end user. The studies presented in this paper address the use of metadata to optimise the consumption of video content on a device of user's choice independent of the nature of the equipment that captured the content. Optimising consumption includes enhancing the quality of image reconstruction on a display. Another part of this project addresses the content-based adaptation of image display. Main focus is on Regions of Interest (ROI) operations, based on the ROI concepts of MPEG-7. The aim of this second part is to characterize and ensure the conditions of display even if display device or display media changes. This requires firstly the definition of a reference color space and the definition of bi-directional color transformations for each peripheral device (camera, display, film recorder, etc.). The complicating factor is that different devices have different color gamuts, depending on the chromaticity of their primaries and the ambient illumination under which they are viewed. To match the displayed image to the aimed appearance, all kind of production metadata (camera specification, camera colour primaries, lighting conditions) should be associated to the film material. Metadata and content build together rich content. The author is assumed to specify conditions as known from digital graphics arts. To control image pre-processing and image post-processing, these specifications should be contained in the film's metadata. The specifications are related to the ICC profiles but need additionally consider mesopic viewing conditions.

  10. Image Quality Analysis and Optical Performance Requirement for Micromirror-Based Lissajous Scanning Displays

    PubMed Central

    Du, Weiqi; Zhang, Gaofei; Ye, Liangchen

    2016-01-01

    Micromirror-based scanning displays have been the focus of a variety of applications. Lissajous scanning displays have advantages in terms of power consumption; however, the image quality is not good enough. The main reason for this is the varying size and the contrast ratio of pixels at different positions of the image. In this paper, the Lissajous scanning trajectory is analyzed and a new method based on the diamond pixel is introduced to Lissajous displays. The optical performance of micromirrors is discussed. A display system demonstrator is built, and tests of resolution and contrast ratio are conducted. The test results show that the new Lissajous scanning method can be used in displays by using diamond pixels and image quality remains stable at different positions. PMID:27187390

  11. Image Quality Analysis and Optical Performance Requirement for Micromirror-Based Lissajous Scanning Displays.

    PubMed

    Du, Weiqi; Zhang, Gaofei; Ye, Liangchen

    2016-05-11

    Micromirror-based scanning displays have been the focus of a variety of applications. Lissajous scanning displays have advantages in terms of power consumption; however, the image quality is not good enough. The main reason for this is the varying size and the contrast ratio of pixels at different positions of the image. In this paper, the Lissajous scanning trajectory is analyzed and a new method based on the diamond pixel is introduced to Lissajous displays. The optical performance of micromirrors is discussed. A display system demonstrator is built, and tests of resolution and contrast ratio are conducted. The test results show that the new Lissajous scanning method can be used in displays by using diamond pixels and image quality remains stable at different positions.

  12. Optical see-through head-mounted display with occlusion capability

    NASA Astrophysics Data System (ADS)

    Gao, Chunyu; Lin, Yuxiang; Hua, Hong

    2013-05-01

    Lack of mutual occlusion capability between computer-rendered and real objects is one of fundamental problems for most existing optical see-through head-mounted displays (OST-HMD). Without the proper occlusion management, the virtual view through an OST-HMD appears "ghost-like", floating in the real world. To address this challenge, we have developed an innovative optical scheme that uniquely combines the eyepiece and see-through relay optics to achieve an occlusion-capable OST-HMD system with a very compelling form factor and high optical performances. The proposed display system was based on emerging freeform optical design technologies and was designed for highly efficient liquid crystal on silicon (LCoS) type spatial light modulator (SLM) and bright Organic LED (OLED) microdisplay. The proposed display technology was capable of working in both indoor and outdoor environments. Our current design offered a 1280x1024 color resolution based on 0.8" microdisplay and SLM. The MTF values for the majority of the fields at the cutoff frequency of 40lps/mm, which is determined by the pixel size of the microdisplay, are better than 15%. The design achieved a diagonal FOV of 40 degrees, 31.7 degrees horizontally and 25.6 degrees vertically, an exit pupil diameter of 8mm (non-vignetted), and an eye clearance of 18mm. The optics weights about 20 grams per eye. Our proposed occlusion capable OST-HMD system can easily find myriads of applications in various military and commercial sectors such as military training, gaming and entertainment.

  13. Tactile feedback to the palm using arbitrarily shaped DEA

    NASA Astrophysics Data System (ADS)

    Mößinger, Holger; Haus, Henry; Kauer, Michaela; Schlaak, Helmut F.

    2014-03-01

    Tactile stimulation enhances user experience and efficiency in human machine interaction by providing information via another sensory channel to the human brain. DEA as tactile interfaces have been in the focus of research in recent years. Examples are (vibro-) tactile keyboards or Braille displays. These applications of DEA focus mainly on interfacing with the user's fingers or fingertips only - demonstrating the high spatial resolution achievable with DEA. Besides providing a high resolution, the flexibility of DEA also allows designing free form surfaces equipped with single actuators or actuator matrices which can be fitted to the surface of the human skin. The actuators can then be used to provide tactile stimuli to different areas of the body, not to the fingertips only. Utilizing and demonstrating this flexibility we designed a free form DEA pad shaped to fit into the inside of the human palm. This pad consists of four single actuators which can provide e.g. directional information such as left, right, up and down. To demonstrate the value of such free form actuators we manufactured a PC-mouse using 3d printing processes. The actuator pad is mounted on the back of the mouse, resting against the palm while operating it. Software on the PC allows control of the vibration patterns displayed by the actuators. This allows helping the user by raising attention to certain directions or by discriminating between different modes like "pick" or "manipulate". Results of first tests of the device show an improved user experience while operating the PC mouse.

  14. Accuracy of remote electrocardiogram interpretation with the use of Google Glass technology.

    PubMed

    Jeroudi, Omar M; Christakopoulos, George; Christopoulos, George; Kotsia, Anna; Kypreos, Megan A; Rangan, Bavana V; Banerjee, Subhash; Brilakis, Emmanouil S

    2015-02-01

    We sought to investigate the accuracy of remote electrocardiogram (ECG) interpretation using Google Glass (Google, Mountain View, California). Google Glass is an optical head mounted display device with growing applications in medicine. We compared interpretation of 10 ECGs with 21 clinically important findings by faculty and fellow cardiologists by (1) viewing the electrocardiographic image at the Google Glass screen; (2) viewing a photograph of the ECG taken using Google Glass and interpreted on a mobile device; (3) viewing the original paper ECG; and (4) viewing a photograph of the ECG taken with a high-resolution camera and interpreted on a mobile device. One point was given for identification of each correct finding. Subjective rating of the user experience was also recorded. Twelve physicians (4 faculty and 8 fellow cardiologists) participated. The average electrocardiographic interpretation score (maximum 21 points) as viewed through the Google Glass, Google Glass photograph on a mobile device, on paper, and high-resolution photograph on a mobile device was 13.5 ± 1.8, 16.1 ± 2.6, 18.3 ± 1.7, and 18.6 ± 1.5, respectively (p = 0.0005 between Google Glass and mobile device, p = 0.0005 between Google Glass and paper, and p = 0.002 between mobile device and paper). Of the 12 physicians, 9 (75%) were dissatisfied with ECGs viewing on the prism display of Google Glass. In conclusion, further improvements are needed before Google Glass can be reliably used for remote electrocardiographic analysis. Published by Elsevier Inc.

  15. On the influence of zero-padding on the nonlinear operations in Quantitative Susceptibility Mapping

    PubMed Central

    Eskreis-Winkler, Sarah; Zhou, Dong; Liu, Tian; Gupta, Ajay; Gauthier, Susan A.; Wang, Yi; Spincemaille, Pascal

    2016-01-01

    Purpose Zero padding is a well-studied interpolation technique that improves image visualization without increasing image resolution. This interpolation is often performed as a last step before images are displayed on clinical workstations. Here, we seek to demonstrate the importance of zero padding before rather than after performing non-linear post-processing algorithms, such as Quantitative Susceptibility Mapping (QSM). To do so, we evaluate apparent spatial resolution, relative error and depiction of multiple sclerosis (MS) lesions on images that were zero padded prior to, in the middle of, and after the application of the QSM algorithm. Materials and Methods High resolution gradient echo (GRE) data were acquired on twenty MS patients, from which low resolution data were derived using k-space cropping. Pre-, mid-, and post-zero padded QSM images were reconstructed from these low resolution data by zero padding prior to field mapping, after field mapping, and after susceptibility mapping, respectively. Using high resolution QSM as the gold standard, apparent spatial resolution, relative error, and image quality of the pre-, mid-, and post-zero padded QSM images were measured and compared. Results Both the accuracy and apparent spatial resolution of the pre-zero padded QSM was higher than that of mid-zero padded QSM (p < 0.001; p < 0.001), which was higher than that of post-zero padded QSM (p < 0.001; p < 0.001). The image quality of pre-zero padded reconstructions was higher than that of mid- and post-zero padded reconstructions (p = 0.004; p < 0.001). Conclusion Zero padding of the complex GRE data prior to nonlinear susceptibility mapping improves image accuracy and apparent resolution compared to zero padding afterwards. It also provides better delineation of MS lesion geometry, which may improve lesion subclassification and disease monitoring in MS patients. PMID:27587225

  16. On the influence of zero-padding on the nonlinear operations in Quantitative Susceptibility Mapping.

    PubMed

    Eskreis-Winkler, Sarah; Zhou, Dong; Liu, Tian; Gupta, Ajay; Gauthier, Susan A; Wang, Yi; Spincemaille, Pascal

    2017-01-01

    Zero padding is a well-studied interpolation technique that improves image visualization without increasing image resolution. This interpolation is often performed as a last step before images are displayed on clinical workstations. Here, we seek to demonstrate the importance of zero padding before rather than after performing non-linear post-processing algorithms, such as Quantitative Susceptibility Mapping (QSM). To do so, we evaluate apparent spatial resolution, relative error and depiction of multiple sclerosis (MS) lesions on images that were zero padded prior to, in the middle of, and after the application of the QSM algorithm. High resolution gradient echo (GRE) data were acquired on twenty MS patients, from which low resolution data were derived using k-space cropping. Pre-, mid-, and post-zero padded QSM images were reconstructed from these low resolution data by zero padding prior to field mapping, after field mapping, and after susceptibility mapping, respectively. Using high resolution QSM as the gold standard, apparent spatial resolution, relative error, and image quality of the pre-, mid-, and post-zero padded QSM images were measured and compared. Both the accuracy and apparent spatial resolution of the pre-zero padded QSM was higher than that of mid-zero padded QSM (p<0.001; p<0.001), which was higher than that of post-zero padded QSM (p<0.001; p<0.001). The image quality of pre-zero padded reconstructions was higher than that of mid- and post-zero padded reconstructions (p=0.004; p<0.001). Zero padding of the complex GRE data prior to nonlinear susceptibility mapping improves image accuracy and apparent resolution compared to zero padding afterwards. It also provides better delineation of MS lesion geometry, which may improve lesion subclassification and disease monitoring in MS patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. The impact of human factors, crashworthiness and optical performance design requirements on helmet-mounted display development from the 1970s to the present

    NASA Astrophysics Data System (ADS)

    Harding, Thomas H.; Rash, Clarence E.; McLean, William E.; Martin, John S.

    2015-05-01

    Driven by the operational needs of modern warfare, the helmet-mounted display (HMD) has matured from a revolutionary, but impractical, World War I era idea for an infantry marksman's helmet-mounted weapon delivery system to a sophisticated and ubiquitous display and targeting system that dominates current night warfighting operations. One of the most demanding applications for HMD designs has been in Army rotary-wing aviation, where HMDs offer greater direct access to visual information and increased situational awareness in an operational environment where information availability is critical on a second-to-second basis. However, over the past 40 years of extensive HMD development, a myriad of crashworthiness, optical, and human factors issues have both frustrated and challenged designers. While it may be difficult to attain a full consensus on which are the most important HMD design factors, certainly head-supported weight (HSW), exit pupil size, field-of-view, image resolution and physical eye relief have been among the most critical. A confounding factor has been the interrelationship between the many design issues, such as early attempts to use non-glass optical elements to lower HSW, but at the cost of image quality, and hence, pilot visual performance. This paper traces how the role of the demanding performance requirements placed on HMDs by the U.S. Army aviation community has impacted the progress of HMD designs towards the Holy Grail of HMD design: a wide field-of-view, high resolution, binocular, full-color, totally crashworthy system.

  18. 3D visualization of ultra-fine ICON climate simulation data

    NASA Astrophysics Data System (ADS)

    Röber, Niklas; Spickermann, Dela; Böttinger, Michael

    2016-04-01

    Advances in high performance computing and model development allow the simulation of finer and more detailed climate experiments. The new ICON model is based on an unstructured triangular grid and can be used for a wide range of applications, ranging from global coupled climate simulations down to very detailed and high resolution regional experiments. It consists of an atmospheric and an oceanic component and scales very well for high numbers of cores. This allows us to conduct very detailed climate experiments with ultra-fine resolutions. ICON is jointly developed in partnership with DKRZ by the Max Planck Institute for Meteorology and the German Weather Service. This presentation discusses our current workflow for analyzing and visualizing this high resolution data. The ICON model has been used for eddy resolving (<10km) ocean simulations, as well as for ultra-fine cloud resolving (120m) atmospheric simulations. This results in very large 3D time dependent multi-variate data that need to be displayed and analyzed. We have developed specific plugins for the free available visualization software ParaView and Vapor, which allows us to read and handle that much data. Within ParaView, we can additionally compare prognostic variables with performance data side by side to investigate the performance and scalability of the model. With the simulation running in parallel on several hundred nodes, an equal load balance is imperative. In our presentation we show visualizations of high-resolution ICON oceanographic and HDCP2 atmospheric simulations that were created using ParaView and Vapor. Furthermore we discuss our current efforts to improve our visualization capabilities, thereby exploring the potential of regular in-situ visualization, as well as of in-situ compression / post visualization.

  19. Characterization of shape and deformation of MEMS by quantitative optoelectronic metrology techniques

    NASA Astrophysics Data System (ADS)

    Furlong, Cosme; Pryputniewicz, Ryszard J.

    2002-06-01

    Recent technological trends based on miniaturization of mechanical, electro-mechanical, and photonic devices to the microscopic scale, have led to the development of microelectromechanical systems (MEMS). Effective development of MEMS components requires the synergism of advanced design, analysis, and fabrication methodologies, and also of quantitative metrology techniques for characterizing their performance, reliability, and integrity during the electronic packaging cycle. In this paper, we describe opto-electronic techniques for measuring, with sub-micrometer accuracy, shape and changes in states of deformation of MEMS strictures. With the described opto-electronic techniques, it is possible to characterize MEMS components using the display and data modes. In the display mode, interferometric information related to shape and deformation is displayed at video frame rates, providing the capability for adjusting and setting experimental conditions. In the data mode, interferometric information related to shape and deformation is recorded as high-spatial and high-digital resolution images, which are further processed to provide quantitative 3D information. Furthermore, the quantitative 3D data are exported to computer-aided design (CAD) environments and utilized for analysis and optimization of MEMS devices. Capabilities of opto- electronic techniques are illustrated with representative applications demonstrating their applicability to provide indispensable quantitative information for the effective development and optimization of MEMS devices.

  20. A Framework for Realistic Modeling and Display of Object Surface Appearance

    NASA Astrophysics Data System (ADS)

    Darling, Benjamin A.

    With advances in screen and video hardware technology, the type of content presented on computers has progressed from text and simple shapes to high-resolution photographs, photorealistic renderings, and high-definition video. At the same time, there have been significant advances in the area of content capture, with the development of devices and methods for creating rich digital representations of real-world objects. Unlike photo or video capture, which provide a fixed record of the light in a scene, these new technologies provide information on the underlying properties of the objects, allowing their appearance to be simulated for novel lighting and viewing conditions. These capabilities provide an opportunity to continue the computer display progression, from high-fidelity image presentations to digital surrogates that recreate the experience of directly viewing objects in the real world. In this dissertation, a framework was developed for representing objects with complex color, gloss, and texture properties and displaying them onscreen to appear as if they are part of the real-world environment. At its core, there is a conceptual shift from a traditional image-based display workflow to an object-based one. Instead of presenting the stored patterns of light from a scene, the objective is to reproduce the appearance attributes of a stored object by simulating its dynamic patterns of light for the real viewing and lighting geometry. This is accomplished using a computational approach where the physical light sources are modeled and the observer and display screen are actively tracked. Surface colors are calculated for the real spectral composition of the illumination with a custom multispectral rendering pipeline. In a set of experiments, the accuracy of color and gloss reproduction was evaluated by measuring the screen directly with a spectroradiometer. Gloss reproduction was assessed by comparing gonio measurements of the screen output to measurements of the real samples in the same measurement configuration. A chromatic adaptation experiment was performed to evaluate color appearance in the framework and explore the factors that contribute to differences when viewing self-luminous displays as opposed to reflective objects. A set of sample applications was developed to demonstrate the potential utility of the object display technology for digital proofing, psychophysical testing, and artwork display.

  1. Liquid Crystal on Silicon Wavefront Corrector

    NASA Technical Reports Server (NTRS)

    Pouch, John; Miranda, Felix; Wang, Xinghua; Bos, Philip, J.

    2004-01-01

    A low cost, high resolution, liquid crystal on silicon, spatial light modulator has been developed for the correction of huge aberrations in an optical system where the polarization dependence and the chromatic nature are tolerated. However, the overall system performance suggests that this device is also suitable for real time correction of aberration in human eyes. This device has a resolution of 1024 x 768, and is driven by an XGA display driver. The effective stroke length of the device is 700 nm and 2000 nm for the visible and IR regions of the device, respectively. The response speeds are 50 Hz and 5 Hz, respectively, which are fast enough for real time adaptive optics for aberrations in human eyes. By modulating a wavefront of 2 pi, this device can correct for arbitrary high order wavefront aberrations since the 2-D pixel array is independently controlled by the driver. The high resolution and high accuracy of the device allow for diffraction limited correction of the tip and tilt or defocus without an additional correction loop. We have shown that for every wave of aberration, an 8 step blazed grating is required to achieve high diffraction efficiency around 80%. In light of this, up to 125 waves peak to valley of tip and tilt can be corrected if we choose the simplest aberration. Corrections of 34 waves of aberration, including high order Zernicke terms in a high magnification telescope, to diffraction limited performance (residual wavefront aberration less than 1/30 lambda at 632.8 nm) have been observed at high efficiency.

  2. Real-time image processing for non-contact monitoring of dynamic displacements using smartphone technologies

    NASA Astrophysics Data System (ADS)

    Min, Jae-Hong; Gelo, Nikolas J.; Jo, Hongki

    2016-04-01

    The newly developed smartphone application, named RINO, in this study allows measuring absolute dynamic displacements and processing them in real time using state-of-the-art smartphone technologies, such as high-performance graphics processing unit (GPU), in addition to already powerful CPU and memories, embedded high-speed/ resolution camera, and open-source computer vision libraries. A carefully designed color-patterned target and user-adjustable crop filter enable accurate and fast image processing, allowing up to 240fps for complete displacement calculation and real-time display. The performances of the developed smartphone application are experimentally validated, showing comparable accuracy with those of conventional laser displacement sensor.

  3. Low-cost, high-speed back-end processing system for high-frequency ultrasound B-mode imaging.

    PubMed

    Chang, Jin Ho; Sun, Lei; Yen, Jesse T; Shung, K Kirk

    2009-07-01

    For real-time visualization of the mouse heart (6 to 13 beats per second), a back-end processing system involving high-speed signal processing functions to form and display images has been developed. This back-end system was designed with new signal processing algorithms to achieve a frame rate of more than 400 images per second. These algorithms were implemented in a simple and cost-effective manner with a single field-programmable gate array (FPGA) and software programs written in C++. The operating speed of the back-end system was investigated by recording the time required for transferring an image to a personal computer. Experimental results showed that the back-end system is capable of producing 433 images per second. To evaluate the imaging performance of the back-end system, a complete imaging system was built. This imaging system, which consisted of a recently reported high-speed mechanical sector scanner assembled with the back-end system, was tested by imaging a wire phantom, a pig eye (in vitro), and a mouse heart (in vivo). It was shown that this system is capable of providing high spatial resolution images with fast temporal resolution.

  4. Low-Cost, High-Speed Back-End Processing System for High-Frequency Ultrasound B-Mode Imaging

    PubMed Central

    Chang, Jin Ho; Sun, Lei; Yen, Jesse T.; Shung, K. Kirk

    2009-01-01

    For real-time visualization of the mouse heart (6 to 13 beats per second), a back-end processing system involving high-speed signal processing functions to form and display images has been developed. This back-end system was designed with new signal processing algorithms to achieve a frame rate of more than 400 images per second. These algorithms were implemented in a simple and cost-effective manner with a single field-programmable gate array (FPGA) and software programs written in C++. The operating speed of the back-end system was investigated by recording the time required for transferring an image to a personal computer. Experimental results showed that the back-end system is capable of producing 433 images per second. To evaluate the imaging performance of the back-end system, a complete imaging system was built. This imaging system, which consisted of a recently reported high-speed mechanical sector scanner assembled with the back-end system, was tested by imaging a wire phantom, a pig eye (in vitro), and a mouse heart (in vivo). It was shown that this system is capable of providing high spatial resolution images with fast temporal resolution. PMID:19574160

  5. Use of PCR with Sequence-specific Primers for High-Resolution Human Leukocyte Antigen Typing of Patients with Narcolepsy

    PubMed Central

    Woo, Hye In; Joo, Eun Yeon; Lee, Kyung Wha

    2012-01-01

    Background Narcolepsy is a neurologic disorder characterized by excessive daytime sleepiness, symptoms of abnormal rapid eye movement (REM) sleep, and a strong association with HLA-DRB1*1501, -DQA1*0102, and -DQB1*0602. Here, we investigated the clinico-physical characteristics of Korean patients with narcolepsy, their HLA types, and the clinical utility of high-resolution PCR with sequence-specific primers (PCR-SSP) as a simple typing method for identifying DRB1*15/16, DQA1, and DQB1 alleles. Methods The study population consisted of 67 consecutively enrolled patients having unexplained daytime sleepiness and diagnosed narcolepsy based on clinical and neurological findings. Clinical data and the results of the multiple sleep latency test and polysomnography were reviewed, and HLA typing was performed using both high-resolution PCR-SSP and sequence-based typing (SBT). Results The 44 narcolepsy patients with cataplexy displayed significantly higher frequencies of DRB1*1501 (Pc= 0.003), DQA1*0102 (Pc=0.001), and DQB1*0602 (Pc=0.014) than the patients without cataplexy. Among patients carrying DRB1*1501-DQB1*0602 or DQA1*0102, the frequencies of a mean REM sleep latency of less than 20 min in nocturnal polysomnography and clinical findings, including sleep paralysis and hypnagogic hallucination were significantly higher. SBT and PCR-SSP showed 100% concordance for high-resolution typing of DRB1*15/16 alleles and DQA1 and DQB1 loci. Conclusions The clinical characteristics and somnographic findings of narcolepsy patients were associated with specific HLA alleles, including DRB1*1501, DQA1*0102, and DQB1*0602. Application of high-resolution PCR-SSP, a reliable and simple method, for both allele- and locus-specific HLA typing of DRB1*15/16, DQA1, and DQB1 would be useful for characterizing clinical status among subjects with narcolepsy. PMID:22259780

  6. A new way of controlling NesCOPOs (nested cavity doubly resonant OPO) for faster and more efficient high resolution spectrum measurement

    NASA Astrophysics Data System (ADS)

    Georges des Aulnois, Johann; Szymanski, Benjamin; Grimieau, Axel; Sillard, Léo.

    2018-02-01

    Optical Parametric Oscillator (OPO) is a well-known solution when wide tunability in the mid-infrared is needed. A specific design called NesCOPO (Nested Cavity doubly resonant OPO) is currently integrated in the X-FLR8 portable gas analyzer from Blue Industry and Science. Thanks to its low threshold this OPO can be pumped by a micro-chip nanosecond YAG (4 kHz repetition rate and a 30 GHz bandwidth). To achieve very high resolution spectra (10 pm of resolution or better), the emitted wavelength has to be finely controlled. Commercial Wavemeter do not meet price and compactness required in the context of an affordable and portable gas analyzer. To overcome this issue, Blue first integrated an active wavelength controller using multiple tunable Fabry-Perot (FP) interferometers. The required resolution was achieved at a 10 Hz measurement rate. We now present an enhanced Wavemeter architecture, based on fixed FP etalons, that is 100 times faster and 2 times smaller. We avoid having FP `blind zones' thanks to one source characteristic: the knowledge of the FSR (Free Spectral Range) of the OPO source and thus, the fact that only discrete wavelengths can be emitted. First results are displayed showing faster measurement for spectroscopic application, and potential future improvement of the device are discussed.

  7. New Visualization Techniques to Analyze Ultra-High Resolution Four-dimensional Surface Deformation Imagery Collected With Ground-based Tripod LiDAR

    NASA Astrophysics Data System (ADS)

    Kreylos, O.; Bawden, G. W.; Kellogg, L. H.

    2005-12-01

    We are developing a visualization application to display and interact with very large (tens of millions of points) four-dimensional point position datasets in an immersive environment such that point groups from repeated Tripod LiDAR (Light Detection And Ranging) surveys can be selected, measured, and analyzed for land surface change using 3D~interactions. Ground-based tripod or terrestrial LiDAR (T-LiDAR) can remotely collect ultra-high resolution (centimeter to subcentimeter) and accurate (± 4 mm) digital imagery of the scanned target, and at scanning rates of 2,000 (x, y, z, i) (3D~position~+ intensity) points per second over 7~million points can be collected for a given target in an hour. We developed a multiresolution point set data representation based on octrees to display large T-LiDAR point cloud datasets at the frame rates required for immersive display (between 60 Hz and 120 Hz). Data inside an observer's region of interest is shown in full detail, whereas data outside the field of view or far away from the observer is shown at reduced resolution to provide context. Using 3D input devices at the University of California Davis KeckCAVES, users can navigate large point sets, accurately select related point groups in two or more point sets by sweeping regions of space, and guide the software in deriving positional information from point groups to compute their displacements between surveys. We used this new software application in the KeckCAVES to analyze 4D T-LiDAR imagery from the June~1, 2005 Blue Bird Canyon landslide in Laguna Beach, southern California. Over 50~million (x, y, z, i) data points were collected between 10 and 21~days after the landslide to evaluate T-LiDAR as a natural hazards response tool. The visualization of the T-LiDAR scans within the immediate landslide showed minor readjustments in the weeks following the primarily landslide with no observable continued motion on the primary landslide. Recovery and demolition efforts across the landslide, such as the building of new roads and removal of unstable structures, are easily identified and assessed with the new software through the differencing of aligned imagery.

  8. Three-dimensional holographic display of ultrasound computed tomograms

    NASA Astrophysics Data System (ADS)

    Andre, Michael P.; Janee, Helmar S.; Ysrael, Mariana Z.; Hodler, Jeurg; Olson, Linda K.; Leopold, George R.; Schulz, Raymond

    1997-05-01

    Breast ultrasound is a valuable adjunct to mammography but is limited by a very small field of view, particularly with high-resolution transducers necessary for breast diagnosis. We have been developing an ultrasound system based on a diffraction tomography method that provides slices through the breast on a large 20-cm diameter circular field of view. Eight to fifteen images are typically produced in sequential coronal planes from the nipple to the chest wall with either 0.25 or 0.5 mm pixels. As a means to simplify the interpretation of this large set of images, we report experience with 3D life-sized displays of the entire breast of human volunteers using a digital holographic technique. The compound 3D holographic images are produced from the digital image matrix, recorded on 14 X 17 inch transparency and projected on a special white-light viewbox. Holographic visualization of the entire breast has proved to be the preferred method for 3D display of ultrasound computed tomography images. It provides a unique perspective on breast anatomy and may prove useful for biopsy guidance and surgical planning.

  9. BactoGeNIE: A large-scale comparative genome visualization for big displays

    DOE PAGES

    Aurisano, Jillian; Reda, Khairi; Johnson, Andrew; ...

    2015-08-13

    The volume of complete bacterial genome sequence data available to comparative genomics researchers is rapidly increasing. However, visualizations in comparative genomics--which aim to enable analysis tasks across collections of genomes--suffer from visual scalability issues. While large, multi-tiled and high-resolution displays have the potential to address scalability issues, new approaches are needed to take advantage of such environments, in order to enable the effective visual analysis of large genomics datasets. In this paper, we present Bacterial Gene Neighborhood Investigation Environment, or BactoGeNIE, a novel and visually scalable design for comparative gene neighborhood analysis on large display environments. We evaluate BactoGeNIE throughmore » a case study on close to 700 draft Escherichia coli genomes, and present lessons learned from our design process. In conclusion, BactoGeNIE accommodates comparative tasks over substantially larger collections of neighborhoods than existing tools and explicitly addresses visual scalability. Given current trends in data generation, scalable designs of this type may inform visualization design for large-scale comparative research problems in genomics.« less

  10. BactoGeNIE: a large-scale comparative genome visualization for big displays

    PubMed Central

    2015-01-01

    Background The volume of complete bacterial genome sequence data available to comparative genomics researchers is rapidly increasing. However, visualizations in comparative genomics--which aim to enable analysis tasks across collections of genomes--suffer from visual scalability issues. While large, multi-tiled and high-resolution displays have the potential to address scalability issues, new approaches are needed to take advantage of such environments, in order to enable the effective visual analysis of large genomics datasets. Results In this paper, we present Bacterial Gene Neighborhood Investigation Environment, or BactoGeNIE, a novel and visually scalable design for comparative gene neighborhood analysis on large display environments. We evaluate BactoGeNIE through a case study on close to 700 draft Escherichia coli genomes, and present lessons learned from our design process. Conclusions BactoGeNIE accommodates comparative tasks over substantially larger collections of neighborhoods than existing tools and explicitly addresses visual scalability. Given current trends in data generation, scalable designs of this type may inform visualization design for large-scale comparative research problems in genomics. PMID:26329021

  11. BactoGeNIE: A large-scale comparative genome visualization for big displays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aurisano, Jillian; Reda, Khairi; Johnson, Andrew

    The volume of complete bacterial genome sequence data available to comparative genomics researchers is rapidly increasing. However, visualizations in comparative genomics--which aim to enable analysis tasks across collections of genomes--suffer from visual scalability issues. While large, multi-tiled and high-resolution displays have the potential to address scalability issues, new approaches are needed to take advantage of such environments, in order to enable the effective visual analysis of large genomics datasets. In this paper, we present Bacterial Gene Neighborhood Investigation Environment, or BactoGeNIE, a novel and visually scalable design for comparative gene neighborhood analysis on large display environments. We evaluate BactoGeNIE throughmore » a case study on close to 700 draft Escherichia coli genomes, and present lessons learned from our design process. In conclusion, BactoGeNIE accommodates comparative tasks over substantially larger collections of neighborhoods than existing tools and explicitly addresses visual scalability. Given current trends in data generation, scalable designs of this type may inform visualization design for large-scale comparative research problems in genomics.« less

  12. Fast algorithm of low power image reformation for OLED display

    NASA Astrophysics Data System (ADS)

    Lee, Myungwoo; Kim, Taewhan

    2014-04-01

    We propose a fast algorithm of low-power image reformation for organic light-emitting diode (OLED) display. The proposed algorithm scales the image histogram in a way to reduce power consumption in OLED display by remapping the gray levels of the pixels in the image based on the fast analysis of the histogram of the input image while maintaining contrast of the image. The key idea is that a large number of gray levels are never used in the images and these gray levels can be effectively exploited to reduce power consumption. On the other hand, to maintain the image contrast the gray level remapping is performed by taking into account the object size in the image to which each gray level is applied, that is, reforming little for the gray levels in the objects of large size. Through experiments with 24 Kodak images, it is shown that our proposed algorithm is able to reduce the power consumption by 10% even with 9% contrast enhancement. Our algorithm runs in a linear time so that it can be applied to moving pictures with high resolution.

  13. Structural and electrical properties of conducting diamond nanowires.

    PubMed

    Sankaran, Kamatchi Jothiramalingam; Lin, Yen-Fu; Jian, Wen-Bin; Chen, Huang-Chin; Panda, Kalpataru; Sundaravel, Balakrishnan; Dong, Chung-Li; Tai, Nyan-Hwa; Lin, I-Nan

    2013-02-01

    Conducting diamond nanowires (DNWs) films have been synthesized by N₂-based microwave plasma enhanced chemical vapor deposition. The incorporation of nitrogen into DNWs films is examined by C 1s X-ray photoemission spectroscopy and morphology of DNWs is discerned using field-emission scanning electron microscopy and transmission electron microscopy (TEM). The electron diffraction pattern, the visible-Raman spectroscopy, and the near-edge X-ray absorption fine structure spectroscopy display the coexistence of sp³ diamond and sp² graphitic phases in DNWs films. In addition, the microstructure investigation, carried out by high-resolution TEM with Fourier transformed pattern, indicates diamond grains and graphitic grain boundaries on surface of DNWs. The same result is confirmed by scanning tunneling microscopy and scanning tunneling spectroscopy (STS). Furthermore, the STS spectra of current-voltage curves discover a high tunneling current at the position near the graphitic grain boundaries. These highly conducting regimes of grain boundaries form effective electron paths and its transport mechanism is explained by the three-dimensional (3D) Mott's variable range hopping in a wide temperature from 300 to 20 K. Interestingly, this specific feature of high conducting grain boundaries of DNWs demonstrates a high efficiency in field emission and pave a way to the next generation of high-definition flat panel displays or plasma devices.

  14. Encoding Optoelectrical Sub-Components in an Al2O3 Nanowire for Rewritable High-Resolution Nanopatterning.

    PubMed

    Sun, Bo; Sun, Yong; Wang, Chengxin

    2018-06-14

    Nanoscale encoding denotes the creation of distinct electric and photonic properties within small, artificially defined regions by physical or chemical means. An encoded single nanostructure includes independent subcomponents as functional units that can also work as functional integrated nanosystems. These can be applied in high-resolution displays, detection systems, and even more complex devices. However, there is still no agreed-upon best platform satisfying all requirements. This paper demonstrates a competitive candidate based on defect engineering, that is, low energy focused e-beam-induced oxygen ion migration in a carbon-doped Al 2 O 3 nanowire. The electronic and photonic properties of these singular units are examined to be significantly modified. Their application in a nanoscale steganography strategy was also evaluated in detail. Complex patterns composed of points, lines, and planes were printed on a single nanowire using a focused e-beam and were subsequently erasable via a simple thermal process in air.

  15. New horizons for study of the cardiopulmonary and circulatory systems. [image reconstruction techniques

    NASA Technical Reports Server (NTRS)

    Wood, E. H.

    1976-01-01

    The paper discusses the development of computer-controlled three-dimensional reconstruction techniques designed to determine the dynamic changes in the true shape and dimensions of the epi- and endocardial surfaces of the heart, along with variable time base (stop-action to real-time) displays of the transmural distribution of the coronary microcirculation and the three-dimensional anatomy of the macrovasculature in all regions of the body throughout individual cardiac and/or respiratory cycles. A technique for reconstructing a cross section of the heart from multiplanar videoroentgenograms is outlined. The capability of high spatial and high temporal resolution scanning videodensitometry makes possible measurement of the appearance, mean transit and clearance of roentgen opaque substances in three-dimensional space through the myocardium with a degree of simultaneous anatomic and temporal resolution not obtainable by current isotope techniques. The distribution of a variety of selected chemical elements or biologic materials within a body portion can also be determined.

  16. High-Resolution Melting (HRM) of the Cytochrome B Gene: A Powerful Approach to Identify Blood-Meal Sources in Chagas Disease Vectors

    PubMed Central

    Peña, Victor H.; Fernández, Geysson J.; Gómez-Palacio, Andrés M.; Mejía-Jaramillo, Ana M.; Cantillo, Omar; Triana-Chávez, Omar

    2012-01-01

    Methods to determine blood-meal sources of hematophagous Triatominae bugs (Chagas disease vectors) are serological or based on PCR employing species-specific primers or heteroduplex analysis, but these are expensive, inaccurate, or problematic when the insect has fed on more than one species. To solve those problems, we developed a technique based on HRM analysis of the mitochondrial gene cytochrome B (Cyt b). This technique recognized 14 species involved in several ecoepidemiological cycles of the transmission of Trypanosoma cruzi and it was suitable with DNA extracted from intestinal content and feces 30 days after feeding, revealing a resolution power that can display mixed feedings. Field samples were analyzed showing blood meal sources corresponding to domestic, peridomiciliary and sylvatic cycles. The technique only requires a single pair of primers that amplify the Cyt b gene in vertebrates and no other standardization, making it quick, easy, relatively inexpensive, and highly accurate. PMID:22389739

  17. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

    NASA Astrophysics Data System (ADS)

    Vågberg, William; Larsson, Daniel H.; Li, Mei; Arner, Anders; Hertz, Hans M.

    2015-11-01

    Imaging of muscular structure with cellular or subcellular detail in whole-body animal models is of key importance for understanding muscular disease and assessing interventions. Classical histological methods for high-resolution imaging methods require excision, fixation and staining. Here we show that the three-dimensional muscular structure of unstained whole zebrafish can be imaged with sub-5 μm detail with X-ray phase-contrast tomography. Our method relies on a laboratory propagation-based phase-contrast system tailored for detection of low-contrast 4-6 μm subcellular myofibrils. The method is demonstrated on 20 days post fertilization zebrafish larvae and comparative histology confirms that we resolve individual myofibrils in the whole-body animal. X-ray imaging of healthy zebrafish show the expected structured muscle pattern while specimen with a dystrophin deficiency (sapje) displays an unstructured pattern, typical of Duchenne muscular dystrophy. The method opens up for whole-body imaging with sub-cellular detail also of other types of soft tissue and in different animal models.

  18. Structural Insight into the Assembly of TRPV Channels

    PubMed Central

    Huynh, Kevin W.; Cohen, Matthew R.; Chakrapani, Sudha; Holdaway, Heather A.; Stewart, Phoebe L.; Moiseenkova-Bell, Vera Y.

    2017-01-01

    SUMMARY Transient receptor potential (TRP) proteins are a large family of polymodal nonselective cation channels. The TRP vanilloid (TRPV) subfamily consists of six homologous members with diverse functions. TRPV1–TRPV4 are nonselective cation channels proposed to play a role in nociception, while TRPV5 and TRPV6 are involved in epithelial Ca2+ homeostasis. Here we present the cryo-electron microscopy (cryo-EM) structure of functional, full-length TRPV2 at 13.6 Å resolution. The map reveals that the TRPV2 cytoplasmic domain displays a 4-fold petal-like shape in which high-resolution N-terminal ankyrin repeat domain (ARD) structures can be unambiguously fitted. Fitting of the available ARD structures for other TRPV subfamily members into the TRPV2 EM map suggests that TRPV subfamily members have highly homologous structural topologies. These results allowed us to postulate a structural explanation for the functional diversity among TRPV channels and their differential regulation by proteins and ligands. PMID:24373766

  19. Triblock copolymer matrix-based capillary electrophoretic microdevice for high-resolution multiplex pathogen detection.

    PubMed

    Kim, Se Jin; Shin, Gi Won; Choi, Seok Jin; Hwang, Hee Sung; Jung, Gyoo Yeol; Seo, Tae Seok

    2010-03-01

    Rapid and simple analysis for the multiple target pathogens is critical for patient management. CE-SSCP analysis on a microchip provides high speed, high sensitivity, and a portable genetic analysis platform in molecular diagnostic fields. The capability of separating ssDNA molecules in a capillary electrophoretic microchannel with high resolution is a critical issue to perform the precise interpretation in the electropherogram. In this study, we explored the potential of poly(ethyleneoxide)-poly(propyleneoxide)-poly(ethyleneoxide) (PEO-PPO-PEO) triblock copolymer as a sieving matrix for CE-SSCP analysis on a microdevice. To demonstrate the superior resolving power of PEO-PPO-PEO copolymers, 255-bp PCR amplicons obtained from 16S ribosomal RNA genes of four bacterial species, namely Proteus mirabilis, Haemophilus ducreyi, Pseudomonas aeruginosa, and Neisseria meningitidis, were analyzed in the PEO-PPO-PEO matrix in comparison with 5% linear polyacrylamide and commercial GeneScan gel. Due to enhanced dynamic coating and sieving ability, PEO-PPO-PEO copolymer displayed fourfold enhancement of resolving power in the CE-SSCP to separate same-sized DNA molecules. Fivefold input of genomic DNA of P. aeruginosa and/or N. meningitidis produced proportionally increased corresponding amplicon peaks, enabling correct quantitative analysis in the pathogen detection. Besides the high-resolution sieving capability, a facile loading and replenishment of gel in the microchannel due to thermally reversible gelation property makes PEO-PPO-PEO triblock copolymer an excellent matrix in the CE-SSCP analysis on the microdevice.

  20. Recent progress of flexible AMOLED displays

    NASA Astrophysics Data System (ADS)

    Pang, Huiqing; Rajan, Kamala; Silvernail, Jeff; Mandlik, Prashant; Ma, Ruiqing; Hack, Mike; Brown, Julie J.; Yoo, Juhn S.; Jung, Sang-Hoon; Kim, Yong-Cheol; Byun, Seung-Chan; Kim, Jong-Moo; Yoon, Soo-Young; Kim, Chang-Dong; Hwang, Yong-Kee; Chung, In-Jae; Fletcher, Mark; Green, Derek; Pangle, Mike; McIntyre, Jim; Smith, Randal D.

    2011-03-01

    Significant progress has been made in recent years in flexible AMOLED displays and numerous prototypes have been demonstrated. Replacing rigid glass with flexible substrates and thin-film encapsulation makes displays thinner, lighter, and non-breakable - all attractive features for portable applications. Flexible AMOLEDs equipped with phosphorescent OLEDs are considered one of the best candidates for low-power, rugged, full-color video applications. Recently, we have demonstrated a portable communication display device, built upon a full-color 4.3-inch HVGA foil display with a resolution of 134 dpi using an all-phosphorescent OLED frontplane. The prototype is shaped into a thin and rugged housing that will fit over a user's wrist, providing situational awareness and enabling the wearer to see real-time video and graphics information.

Top