Sample records for high sensitivity compared

  1. The mode of sensitization and its influence on allograft outcomes in highly sensitized kidney transplant recipients.

    PubMed

    Redfield, Robert R; Scalea, Joseph R; Zens, Tiffany J; Mandelbrot, Didier A; Leverson, Glen; Kaufman, Dixon B; Djamali, Arjang

    2016-10-01

    We sought to determine whether the mode of sensitization in highly sensitized patients contributed to kidney allograft survival. An analysis of the United Network for Organ Sharing dataset involving all kidney transplants between 1997 and 2014 was undertaken. Highly sensitized adult kidney transplant recipients [panel reactive antibody (PRA) ≥98%] were compared with adult, primary non-sensitized and re-transplant recipients. Kaplan-Meier survival analyses were used to determine allograft survival rates. Cox proportional hazards regression analyses were conducted to determine the association of graft loss with key predictors. Fifty-three percent of highly sensitized patients transplanted were re-transplants. Pregnancy and transfusion were the only sensitizing event in 20 and 5%, respectively. The 10-year actuarial graft survival for highly sensitized recipients was 43.9% compared with 52.4% for non-sensitized patients, P < 0.001. The combination of being highly sensitized by either pregnancy or blood transfusion increased the risk of graft loss by 23% [hazard ratio (HR) 1.230, confidence interval (CI) 1.150-1.315, P < 0.001], and the combination of being highly sensitized from a prior transplant increased the risk of graft loss by 58.1% (HR 1.581, CI 1.473-1.698, P < 0.001). The mode of sensitization predicts graft survival in highly sensitized kidney transplant recipients (PRA ≥98%). Patients who are highly sensitized from re-transplants have inferior graft survival compared with patients who are highly sensitized from other modes of sensitization. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  2. Comparison of high-sensitivity C-reactive protein and fetuin-A levels before and after treatment for subjects with subclinical hyperthyroidism.

    PubMed

    Bilgir, Oktay; Bilgir, Ferda; Topcuoglu, Tuba; Calan, Mehmet; Calan, Ozlem

    2014-03-01

    This study was designed to show the effect of propylthiouracil treatment on sCD40L, high-sensitivity C-reactive protein, and fetuin-A levels on subjects with subclinical hyperthyroidism. After checking sCD40L, high-sensitivity C-reactive protein, and fetuin-A levels of 35 patients with subclinical hyperthyroidism, each was given 50 mg tablets of propylthiouracil three times daily. After 3 months, sCD40L, high-sensitivity C-reactive protein, and fetuin-A levels were then compared to the levels before treatment. Although high-sensitivity C-reactive protein and sCD40L levels were normal in the subclinical hyperthyroidism patients compared to the healthy controls, fetuin-A levels were statistically significantly higher (*p = 0.022). After treatment, fetuin-A levels of subclinical hyperthyroidism patients decreased statistically significantly compared to the levels before treatment (**p = 0.026). sCD40L and high-sensitivity C-reactive protein levels did not have a statistically significant difference compared to the control group and post-propylthiouracil treatment. In subclinical hyperthyroidism patients, high fetuin-A levels before propylthiouracil treatment and decreases in these levels after treatment in cases with subclinical hyperthyroidism indicated the possibility of preventing long-term cardiac complications with propylthiouracil treatment.

  3. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  4. High-field modulated ion-selective field-effect-transistor (FET) sensors with sensitivity higher than the ideal Nernst sensitivity.

    PubMed

    Chen, Yi-Ting; Sarangadharan, Indu; Sukesan, Revathi; Hseih, Ching-Yen; Lee, Geng-Yen; Chyi, Jen-Inn; Wang, Yu-Lin

    2018-05-29

    Lead ion selective membrane (Pb-ISM) coated AlGaN/GaN high electron mobility transistors (HEMT) was used to demonstrate a whole new methodology for ion-selective FET sensors, which can create ultra-high sensitivity (-36 mV/log [Pb 2+ ]) surpassing the limit of ideal sensitivity (-29.58 mV/log [Pb 2+ ]) in a typical Nernst equation for lead ion. The largely improved sensitivity has tremendously reduced the detection limit (10 -10  M) for several orders of magnitude of lead ion concentration compared to typical ion-selective electrode (ISE) (10 -7  M). The high sensitivity was obtained by creating a strong filed between the gate electrode and the HEMT channel. Systematical investigation was done by measuring different design of the sensor and gate bias, indicating ultra-high sensitivity and ultra-low detection limit obtained only in sufficiently strong field. Theoretical study in the sensitivity consistently agrees with the experimental finding and predicts the maximum and minimum sensitivity. The detection limit of our sensor is comparable to that of Inductively-Coupled-Plasma Mass Spectrum (ICP-MS), which also has detection limit near 10 -10  M.

  5. Eating High Fat Chow Decreases Dopamine Clearance in Adolescent and Adult Male Rats but Selectively Enhances the Locomotor Stimulating Effects of Cocaine in Adolescents

    PubMed Central

    Baladi, Michelle G.; Horton, Rebecca E.; Owens, William A.; Daws, Lynette C.

    2015-01-01

    Background: Feeding conditions can influence dopamine neurotransmission and impact behavioral and neurochemical effects of drugs acting on dopamine systems. This study examined whether eating high fat chow alters the locomotor effects of cocaine and dopamine transporter activity in adolescent (postnatal day 25) and adult (postnatal day 75) male Sprague-Dawley rats. Methods: Dose-response curves for cocaine-induced locomotor activity were generated in rats with free access to either standard or high fat chow or restricted access to high fat chow (body weight matched to rats eating standard chow). Results: Compared with eating standard chow, eating high fat chow increased the sensitivity of adolescent, but not adult, rats to the acute effects of cocaine. When tested once per week, sensitization to the locomotor effects of cocaine was enhanced in adolescent rats eating high fat chow compared with adolescent rats eating standard chow. Sensitization to cocaine was not different among feeding conditions in adults. When adolescent rats that previously ate high fat chow ate standard chow, sensitivity to cocaine returned to normal. As measured by chronoamperometry, dopamine clearance rate in striatum was decreased in both adolescent and adult rats eating high fat chow compared with age-matched rats eating standard chow. Conclusions: These results suggest that high fat diet-induced reductions in dopamine clearance rate do not always correspond to increased sensitivity to the locomotor effects of cocaine, suggesting that mechanisms other than dopamine transporter might play a role. Moreover, in adolescent but not adult rats, eating high fat chow increases sensitivity to cocaine and enhances the sensitization that develops to cocaine. PMID:25805560

  6. Eating high fat chow decreases dopamine clearance in adolescent and adult male rats but selectively enhances the locomotor stimulating effects of cocaine in adolescents.

    PubMed

    Baladi, Michelle G; Horton, Rebecca E; Owens, William A; Daws, Lynette C; France, Charles P

    2015-03-24

    Feeding conditions can influence dopamine neurotransmission and impact behavioral and neurochemical effects of drugs acting on dopamine systems. This study examined whether eating high fat chow alters the locomotor effects of cocaine and dopamine transporter activity in adolescent (postnatal day 25) and adult (postnatal day 75) male Sprague-Dawley rats. Dose-response curves for cocaine-induced locomotor activity were generated in rats with free access to either standard or high fat chow or restricted access to high fat chow (body weight matched to rats eating standard chow). Compared with eating standard chow, eating high fat chow increased the sensitivity of adolescent, but not adult, rats to the acute effects of cocaine. When tested once per week, sensitization to the locomotor effects of cocaine was enhanced in adolescent rats eating high fat chow compared with adolescent rats eating standard chow. Sensitization to cocaine was not different among feeding conditions in adults. When adolescent rats that previously ate high fat chow ate standard chow, sensitivity to cocaine returned to normal. As measured by chronoamperometry, dopamine clearance rate in striatum was decreased in both adolescent and adult rats eating high fat chow compared with age-matched rats eating standard chow. These results suggest that high fat diet-induced reductions in dopamine clearance rate do not always correspond to increased sensitivity to the locomotor effects of cocaine, suggesting that mechanisms other than dopamine transporter might play a role. Moreover, in adolescent but not adult rats, eating high fat chow increases sensitivity to cocaine and enhances the sensitization that develops to cocaine. © The Author 2015. Published by Oxford University Press on behalf of CINP.

  7. Is Comparison the Thief of Joy? Sexual Narcissism and Social Comparisons in the Domain of Sexuality.

    PubMed

    Day, Lisa C; Muise, Amy; Impett, Emily A

    2017-02-01

    Are people who are high in sexual narcissism more sensitive to information comparing their sex lives with the sex lives of others? Does this sensitivity explain narcissists' lower sexual and relationship satisfaction? We conducted three studies to address this question. Participants completed the Sexual Narcissism Scale (Widman & McNulty, 2010), and then either recalled (Study 1), imagined (Study 2), or actually made (Study 3) a sexual comparison. We found that people high in sexual narcissism (compared with those lower in sexual narcissism) were more bothered when comparing themselves with someone with a higher sexual frequency and felt better about a comparison with someone with a lower sexual frequency. In turn, narcissists' greater sensitivity to upward social comparisons predicted lower sexual and relationship satisfaction. These results suggest that those high in sexual narcissism may use downward sexual comparisons to maintain their grandiose self-views and be particularly sensitive to upward sexual comparisons.

  8. Plastic Polymers for Efficient DNA Microarray Hybridization: Application to Microbiological Diagnostics▿

    PubMed Central

    Zhao, Zhengshan; Peytavi, Régis; Diaz-Quijada, Gerardo A.; Picard, Francois J.; Huletsky, Ann; Leblanc, Éric; Frenette, Johanne; Boivin, Guy; Veres, Teodor; Dumoulin, Michel M.; Bergeron, Michel G.

    2008-01-01

    Fabrication of microarray devices using traditional glass slides is not easily adaptable to integration into microfluidic systems. There is thus a need for the development of polymeric materials showing a high hybridization signal-to-background ratio, enabling sensitive detection of microbial pathogens. We have developed such plastic supports suitable for highly sensitive DNA microarray hybridizations. The proof of concept of this microarray technology was done through the detection of four human respiratory viruses that were amplified and labeled with a fluorescent dye via a sensitive reverse transcriptase PCR (RT-PCR) assay. The performance of the microarray hybridization with plastic supports made of PMMA [poly(methylmethacrylate)]-VSUVT or Zeonor 1060R was compared to that with high-quality glass slide microarrays by using both passive and microfluidic hybridization systems. Specific hybridization signal-to-background ratios comparable to that obtained with high-quality commercial glass slides were achieved with both polymeric substrates. Microarray hybridizations demonstrated an analytical sensitivity equivalent to approximately 100 viral genome copies per RT-PCR, which is at least 100-fold higher than the sensitivities of previously reported DNA hybridizations on plastic supports. Testing of these plastic polymers using a microfluidic microarray hybridization platform also showed results that were comparable to those with glass supports. In conclusion, PMMA-VSUVT and Zeonor 1060R are both suitable for highly sensitive microarray hybridizations. PMID:18784318

  9. [Psychological Well-being of Highly-sensitive Persons in Transition to Parenthood - A Cross-sectional Study].

    PubMed

    Schmückle, M; Lindert, J; Schmolz, G

    2017-12-01

    Well-being of highly sensitive people in the transformation period to parenthood is of increasing concern. This study examines whether the transformation period to parenthood has a higher effect on the psychological well-being (PWB) of highly sensitive people than on not highly sensitive people. A cross-sectional study was undertaken of parents (n=614), highly sensitive (n=440) and not highly sensitive (n=174), at the transition to parenthood. Instruments were the Ryff psychological well-being scale. Independent variables and well-being were examined by descriptive and bivariate methods. Well-being of highly sensitive parents is associated with transition to parenthood (b=-10,129; p<0.05) compared to the control group (7.3% of highly sensitive <50% of PWB; 0.6% of not highly sensitive <50% of PWB). As one of the first studies, this examination looks into the data of highly sensitive parents. It can be stated that there is an urgent need for research in this area. Because with a prevalence of 10-20% highly sensitive people within the population, it can be assumed that highly sensitive mostly young parents, could be an important target group of health promotion. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Genetics and clinical response to warfarin and edoxaban in patients with venous thromboembolism

    PubMed Central

    Vandell, Alexander G; Walker, Joseph; Brown, Karen S; Zhang, George; Lin, Min; Grosso, Michael A; Mercuri, Michele F

    2017-01-01

    Objective The aim of this study was to investigate whether genetic variants can identify patients with venous thromboembolism (VTE) at an increased risk of bleeding with warfarin. Methods Hokusai-venous thromboembolism (Hokusai VTE), a randomised, multinational, double-blind, non-inferiority trial, evaluated the safety and efficacy of edoxaban versus warfarin in patients with VTE initially treated with heparin. In this subanalysis of Hokusai VTE, patients genotyped for variants in CYP2C9 and VKORC1 genes were divided into three warfarin sensitivity types (normal, sensitive and highly sensitive) based on their genotypes. An exploratory analysis was also conducted comparing normal responders to pooled sensitive responders (ie, sensitive and highly sensitive responders). Results The analysis included 47.7% (3956/8292) of the patients in Hokusai VTE. Among 1978 patients randomised to warfarin, 63.0% (1247) were normal responders, 34.1% (675) were sensitive responders and 2.8% (56) were highly sensitive responders. Compared with normal responders, sensitive and highly sensitive responders had heparin therapy discontinued earlier (p<0.001), had a decreased final weekly warfarin dose (p<0.001), spent more time overanticoagulated (p<0.001) and had an increased bleeding risk with warfarin (sensitive responders HR 1.38 [95% CI 1.11 to 1.71], p=0.0035; highly sensitive responders 1.79 [1.09 to 2.99]; p=0.0252). Conclusion In this study, CYP2C9 and VKORC1 genotypes identified patients with VTE at increased bleeding risk with warfarin. Trial registration number NCT00986154. PMID:28689179

  11. High refractive index and temperature sensitivity LPGs for high temperature operation

    NASA Astrophysics Data System (ADS)

    Nascimento, I. M.; Gouveia, C.; Jana, Surnimal; Bera, Susanta; Baptista, J. M.; Moreira, Paulo; Biwas, Palas; Bandyopadhyay, Somnath; Jorge, Pedro A. S.

    2013-11-01

    A fiber optic sensor for high sensitivity refractive index and temperature measurement able to withstand temperature up to 450 °C is reported. Two identical LPG gratings were fabricated, whereas one was coated with a high refractive index (~1.78) sol-gel thin film in order to increase its sensitivity to the external refractive index. The two sensors were characterized and compared in refractive index and temperature. Sensitivities of 1063 nm/RIU (1.338 - 1.348) and 260 pm/°C were achieved for refractive index and temperature, respectively.

  12. Development of a highly sensitive three-dimensional gel electrophoresis method for characterization of monoclonal protein heterogeneity.

    PubMed

    Nakano, Keiichi; Tamura, Shogo; Otuka, Kohei; Niizeki, Noriyasu; Shigemura, Masahiko; Shimizu, Chikara; Matsuno, Kazuhiko; Kobayashi, Seiichi; Moriyama, Takanori

    2013-07-15

    Three-dimensional gel electrophoresis (3-DE), which combines agarose gel electrophoresis and isoelectric focusing/SDS-PAGE, was developed to characterize monoclonal proteins (M-proteins). However, the original 3-DE method has not been optimized and its specificity has not been demonstrated. The main goal of this study was to optimize the 3-DE procedure and then compare it with 2-DE. We developed a highly sensitive 3-DE method in which M-proteins are extracted from a first-dimension agarose gel, by diffusing into 150 mM NaCl, and the recovery of M-proteins was 90.6%. To validate the utility of the highly sensitive 3-DE, we compared it with the original 3-DE method. We found that highly sensitive 3-DE provided for greater M-protein recovery and was more effective in terms of detecting spots on SDS-PAGE gels than the original 3-DE. Moreover, highly sensitive 3-DE separates residual normal IgG from M-proteins, which could not be done by 2-DE. Applying the highly sensitive 3-DE to clinical samples, we found that the characteristics of M-proteins vary tremendously between individuals. We believe that our highly sensitive 3-DE method described here will prove useful in further studies of the heterogeneity of M-proteins. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, S; Jung, H; Kim, M

    2014-06-01

    Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulatedmore » dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.« less

  14. Emotional expression recognition and attribution bias among sexual and violent offenders: a signal detection analysis

    PubMed Central

    Gillespie, Steven M.; Rotshtein, Pia; Satherley, Rose-Marie; Beech, Anthony R.; Mitchell, Ian J.

    2015-01-01

    Research with violent offenders has consistently shown impaired recognition of other’s facial expressions of emotion. However, the extent to which similar problems can be observed among sexual offenders remains unknown. Using a computerized task, we presented sexual and violent offenders, and non-offenders, with male and female expressions of anger, disgust, fear, happiness, sadness, and surprise, morphed with neutral expressions at varying levels of intensity (10, 55, and 90% expressive). Based on signal detection theory, we used hit rates and false alarms to calculate the sensitivity index d-prime (d′) and criterion (c) for each emotional expression. Overall, sexual offenders showed reduced sensitivity to emotional expressions across intensity, sex, and type of expression, compared with non-offenders, while both sexual and violent offenders showed particular reduced sensitivity to fearful expressions. We also observed specific effects for high (90%) intensity female faces, with sexual offenders showing reduced sensitivity to anger compared with non-offenders and violent offenders, and reduced sensitivity to disgust compared with non-offenders. Furthermore, both sexual and violent offenders showed impaired sensitivity to high intensity female fearful expressions compared with non-offenders. Violent offenders also showed a higher criterion for classifying moderate and high intensity male expressions as fearful, indicative of a more conservative response style, compared with angry, happy, or sad. These results suggest that both types of offender show problems in emotion recognition, and may have implications for understanding the inhibition of violent and sexually violent behaviors. PMID:26029137

  15. Emotional expression recognition and attribution bias among sexual and violent offenders: a signal detection analysis.

    PubMed

    Gillespie, Steven M; Rotshtein, Pia; Satherley, Rose-Marie; Beech, Anthony R; Mitchell, Ian J

    2015-01-01

    Research with violent offenders has consistently shown impaired recognition of other's facial expressions of emotion. However, the extent to which similar problems can be observed among sexual offenders remains unknown. Using a computerized task, we presented sexual and violent offenders, and non-offenders, with male and female expressions of anger, disgust, fear, happiness, sadness, and surprise, morphed with neutral expressions at varying levels of intensity (10, 55, and 90% expressive). Based on signal detection theory, we used hit rates and false alarms to calculate the sensitivity index d-prime (d') and criterion (c) for each emotional expression. Overall, sexual offenders showed reduced sensitivity to emotional expressions across intensity, sex, and type of expression, compared with non-offenders, while both sexual and violent offenders showed particular reduced sensitivity to fearful expressions. We also observed specific effects for high (90%) intensity female faces, with sexual offenders showing reduced sensitivity to anger compared with non-offenders and violent offenders, and reduced sensitivity to disgust compared with non-offenders. Furthermore, both sexual and violent offenders showed impaired sensitivity to high intensity female fearful expressions compared with non-offenders. Violent offenders also showed a higher criterion for classifying moderate and high intensity male expressions as fearful, indicative of a more conservative response style, compared with angry, happy, or sad. These results suggest that both types of offender show problems in emotion recognition, and may have implications for understanding the inhibition of violent and sexually violent behaviors.

  16. Sensitivity Enhancement in Si Nanophotonic Waveguides Used for Refractive Index Sensing

    PubMed Central

    Shi, Yaocheng; Ma, Ke; Dai, Daoxin

    2016-01-01

    A comparative study is given for the sensitivity of several typical Si nanophotonic waveguides, including SOI (silicon-on-insulator) nanowires, nanoslot waveguides, suspended Si nanowires, and nanofibers. The cases for gas sensing (ncl ~ 1.0) and liquid sensing (ncl ~ 1.33) are considered. When using SOI nanowires (with a SiO2 buffer layer), the sensitivity for liquid sensing (S ~ 0.55) is higher than that for gas sensing (S ~ 0.35) due to lower asymmetry in the vertical direction. By using SOI nanoslot waveguides, suspended Si nanowires, and Si nanofibers, one could achieve a higher sensitivity compared to sensing with a free-space beam (S = 1.0). The sensitivity for gas sensing is higher than that for liquid sensing due to the higher index-contrast. The waveguide sensitivity of an optimized suspended Si nanowire for gas sensing is as high as 1.5, which is much higher than that of a SOI nanoslot waveguide. Furthermore, the optimal design has very large tolerance to the core width variation due to the fabrication error (∆w ~ ±50 nm). In contrast, a Si nanofiber could also give a very high sensitivity (e.g., ~1.43) while the fabrication tolerance is very small (i.e., ∆w < ±5 nm). The comparative study shows that suspended Si nanowire is a good choice to achieve ultra-high waveguide sensitivity. PMID:26950132

  17. Sensitivity Enhancement in Si Nanophotonic Waveguides Used for Refractive Index Sensing.

    PubMed

    Shi, Yaocheng; Ma, Ke; Dai, Daoxin

    2016-03-03

    A comparative study is given for the sensitivity of several typical Si nanophotonic waveguides, including SOI (silicon-on-insulator) nanowires, nanoslot waveguides, suspended Si nanowires, and nanofibers. The cases for gas sensing (ncl ~ 1.0) and liquid sensing (ncl ~ 1.33) are considered. When using SOI nanowires (with a SiO₂ buffer layer), the sensitivity for liquid sensing (S ~ 0.55) is higher than that for gas sensing (S ~ 0.35) due to lower asymmetry in the vertical direction. By using SOI nanoslot waveguides, suspended Si nanowires, and Si nanofibers, one could achieve a higher sensitivity compared to sensing with a free-space beam (S = 1.0). The sensitivity for gas sensing is higher than that for liquid sensing due to the higher index-contrast. The waveguide sensitivity of an optimized suspended Si nanowire for gas sensing is as high as 1.5, which is much higher than that of a SOI nanoslot waveguide. Furthermore, the optimal design has very large tolerance to the core width variation due to the fabrication error (∆w ~ ±50 nm). In contrast, a Si nanofiber could also give a very high sensitivity (e.g., ~1.43) while the fabrication tolerance is very small (i.e., ∆w < ±5 nm). The comparative study shows that suspended Si nanowire is a good choice to achieve ultra-high waveguide sensitivity.

  18. Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay.

    PubMed

    Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D

    2006-02-01

    Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.

  19. Genetics and clinical response to warfarin and edoxaban in patients with venous thromboembolism.

    PubMed

    Vandell, Alexander G; Walker, Joseph; Brown, Karen S; Zhang, George; Lin, Min; Grosso, Michael A; Mercuri, Michele F

    2017-11-01

    The aim of this study was to investigate whether genetic variants can identify patients with venous thromboembolism (VTE) at an increased risk of bleeding with warfarin. Hokusai-venous thromboembolism (Hokusai VTE), a randomised, multinational, double-blind, non-inferiority trial, evaluated the safety and efficacy of edoxaban versus warfarin in patients with VTE initially treated with heparin. In this subanalysis of Hokusai VTE, patients genotyped for variants in CYP2C9 and VKORC1 genes were divided into three warfarin sensitivity types (normal, sensitive and highly sensitive) based on their genotypes. An exploratory analysis was also conducted comparing normal responders to pooled sensitive responders (ie, sensitive and highly sensitive responders). The analysis included 47.7% (3956/8292) of the patients in Hokusai VTE. Among 1978 patients randomised to warfarin, 63.0% (1247) were normal responders, 34.1% (675) were sensitive responders and 2.8% (56) were highly sensitive responders. Compared with normal responders, sensitive and highly sensitive responders had heparin therapy discontinued earlier (p<0.001), had a decreased final weekly warfarin dose (p<0.001), spent more time overanticoagulated (p<0.001) and had an increased bleeding risk with warfarin (sensitive responders HR 1.38 [95% CI 1.11 to 1.71], p=0.0035; highly sensitive responders 1.79 [1.09 to 2.99]; p=0.0252). In this study, CYP2C9 and VKORC1 genotypes identified patients with VTE at increased bleeding risk with warfarin. NCT00986154. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. An efficient protocol for the synthesis of highly sensitive indole imines utilizing green chemistry: optimization of reaction conditions.

    PubMed

    Nisar, Bushra; Rubab, Syeda Laila; Raza, Abdul Rauf; Tariq, Sobia; Sultan, Ayesha; Tahir, Muhammad Nawaz

    2018-04-11

    Novel and highly sensitive indole-based imines have been synthesized. Their synthesis has been compared employing a variety of protocols. Ultimately, a convenient, economical and high yielding set of conditions employing green chemistry have been designed for their synthesis.

  1. Personaltiy correlates of the joy of life.

    PubMed

    Tolor, A

    1978-07-01

    Hypothesized that greater diversity of joy and more intense levels of joy would be associated with low hopelessness, high sensation seeking the perception of the world as just, and high sensitization as compared with high repression. It also was predicted that female Ss would score higher in sources of joy and in intensity as compared to males. One hundred and thirty-four college students were administered the Joy of Life Scale, Hopelessness Scale, Sensation Seeking Scale, Just World Scale, and Revised Repression-Sensitization Scale. The hypothesis was supported for sensation seeking in that High Sensation Seekers assigned significantly (p less than .05) higher mean intensity ratings to experiences that produced joy of life, than did Low Sensation Seekers. Contrary to expectation, there was a nonsignificant trend for sensitizers, when compared with repressors, to select fewer joy-related experiences and to evaluate these experiences as less joyful. The experiences that most often led to high levels of joy were those referrable to positive emotional events.

  2. The road not taken: social vs. private comparisons in Asperger׳s syndrome and high functioning autism.

    PubMed

    Dvash, Jonathan; Ben-Zèev, Aaron; Noga, Adler; Shamay-Tsoory, Simone

    2014-05-30

    Evaluation of the outcomes of our decisions may instigate comparisons of our actual outcome with those of others (social comparisons) or comparisons with alternative outcomes of choices not made (private comparisons). Previous research has suggested a deficit in attention to social information among individuals with autism spectrum disorders. As social comparison involves the processing of social information, here we investigated the orientation towards and sensitivity to social vs. private comparisons in individuals with autism spectrum disorders. We compared the sensitivity to social vs. private comparisons among individuals diagnosed with Asperger's Syndrome (AS) or High Functioning Autism, using a task that entailed monetary rewards. Results showed that while individuals with AS generally demonstrate comparable sensitivity to absolute and relative rewards, they show less sensitivity to social comparison as compared to controls. Furthermore, they are characterized by a higher sensitivity to private rather than social comparison. These results suggest that low sensitivity to social comparisons is an important factor to consider in autism spectrum disorders. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Cluster subgroups based on overall pressure pain sensitivity and psychosocial factors in chronic musculoskeletal pain: Differences in clinical outcomes.

    PubMed

    Almeida, Suzana C; George, Steven Z; Leite, Raquel D V; Oliveira, Anamaria S; Chaves, Thais C

    2018-05-17

    We aimed to empirically derive psychosocial and pain sensitivity subgroups using cluster analysis within a sample of individuals with chronic musculoskeletal pain (CMP) and to investigate derived subgroups for differences in pain and disability outcomes. Eighty female participants with CMP answered psychosocial and disability scales and were assessed for pressure pain sensitivity. A cluster analysis was used to derive subgroups, and analysis of variance (ANOVA) was used to investigate differences between subgroups. Psychosocial factors (kinesiophobia, pain catastrophizing, anxiety, and depression) and overall pressure pain threshold (PPT) were entered into the cluster analysis. Three subgroups were empirically derived: cluster 1 (high pain sensitivity and high psychosocial distress; n = 12) characterized by low overall PPT and high psychosocial scores; cluster 2 (high pain sensitivity and intermediate psychosocial distress; n = 39) characterized by low overall PPT and intermediate psychosocial scores; and cluster 3 (low pain sensitivity and low psychosocial distress; n = 29) characterized by high overall PPT and low psychosocial scores compared to the other subgroups. Cluster 1 showed higher values for mean pain intensity (F (2,77)  = 10.58, p < 0.001) compared with cluster 3, and cluster 1 showed higher values for disability (F (2,77)  = 3.81, p = 0.03) compared with both clusters 2 and 3. Only cluster 1 was distinct from cluster 3 according to both pain and disability outcomes. Pain catastrophizing, depression, and anxiety were the psychosocial variables that best differentiated the subgroups. Overall, these results call attention to the importance of considering pain sensitivity and psychosocial variables to obtain a more comprehensive characterization of CMP patients' subtypes.

  4. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Zhao; Gao, Kun; Chen, Jian

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using themore » error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.« less

  5. Preparation and Characterization of Cyclotrimethylenetrinitramine (RDX) with Reduced Sensitivity

    PubMed Central

    Wang, Yuqiao; Li, Xin; Chen, Shusen; Ma, Xiao; Yu, Ziyang; Jin, Shaohua; Li, Lijie; Chen, Yu

    2017-01-01

    The internal defects and shape of cyclotrimethylenetrinitramine (RDX) crystal are critical parameters for the preparation of reduced sensitivity RDX (RS-RDX). In the current study, RDX was re-crystallized and spheroidized to form the high-quality RDX that was further characterized by purity, apparent density, size distribution, specific surface area, impact sensitivity, and shock sensitivity. The effects of re-crystallization solvent on the growth morphology of RDX crystal were investigated by both theoretical simulation and experiment test, and consistent results were obtained. The high-quality RDX exhibited a high purity (≥99.90%), high apparent density (≥1.811 g/cm3), spherical shape, and relatively low impact sensitivity (6%). Its specific surface area was reduced more than 30%. Compared with conventional RDXs, the high-quality RDX reduced the shock sensitivities of PBXN-109 and PBXW-115 by more than 30%, indicating that it was a RS-RDX. The reduced sensitivity and good processability of the high-quality RDX would be significant in improving the performances of RDX-based PBXs. PMID:28825661

  6. Anxiety sensitivity and expectation of arousal differentially affect the respiratory response to caffeine.

    PubMed

    Pané-Farré, Christiane A; Alius, Manuela G; Modeß, Christiane; Methling, Karen; Blumenthal, Terry; Hamm, Alfons O

    2015-06-01

    This study aimed to test how expectations and anxiety sensitivity influence respiratory and autonomic responses to caffeine. The current study investigated the effects of expected vs. unexpected caffeine ingestion in a group of persons prone to the anxiety-provoking effect of caffeine (high anxiety sensitive persons, that is, persons scoring at least one SD above the mean on the Anxiety Sensitivity Index (Peterson and Reiss 1992)) as compared to low-anxious controls. Autonomic arousal (heart rate, skin conductance level), respiratory responding (expired CO2, minute ventilation), and subjective report were assessed in high and low anxiety sensitive participants immediately after beverage consumption and at absorption peak (30 min post-consumption) in four separate sessions during which either coffee (expectation of caffeine) or bitter lemon soda (no expectation of caffeine) was crossed with 4 mg/kg caffeine vs. no drug. High and low anxiety sensitive persons showed comparable autonomic arousal and symptom reports to caffeine which was modulated by expectation, i.e., greater for coffee. Respiratory responding (CO2 decrease, minute ventilation increase) was more accentuated when caffeine was both expected and administered in the low anxiety sensitive group but more accentuated when caffeine was unexpectedly administered in the high anxiety sensitive group. Autonomic arousal and respiratory effects were observable within a few minutes after caffeine administration and were most pronounced at maximum absorption. The results highlight the modulating role of expectancies in respiratory responding to caffeine in low vs. high anxiety sensitive persons and might have important implications for the better understanding of unexpected panic attacks.

  7. Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI.

    PubMed

    Kondo, Takashi; Kobayashi, Daisuke; Mochizuki, Maki; Asanuma, Kouichi; Takahashi, Satoshi

    2017-01-01

    Background Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. However, differences in measured values between these new reagents and previously used reagents have not been well studied. In this study, we aimed to compare the values between ARCHITECT High-Sensitive Troponin I ST (newly developed reagents), ARCHITECT Troponin I ST and STACIA CLEIA cardiac troponin I (two previously developed reagent kits). Methods Gel filtration high-performance liquid chromatography was used to analyse the causes of differences in measured values. Results The measured values differed between ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cardiac troponin I reagents (r = 0.82). Cross-reactivity tests using plasma with added skeletal-muscle troponin I resulted in higher reactivity (2.17-3.03%) for the STACIA CLEIA cardiac troponin I reagents compared with that for the ARCHITECT High-Sensitive Troponin I ST reagents (less than 0.014%). In addition, analysis of three representative samples using gel filtration high-performance liquid chromatography revealed reagent-specific differences in the reactivity against each cardiac troponin I complex; this could explain the differences in values observed for some of the samples. Conclusion The newly developed ARCHITECT High-Sensitive Troponin I ST reagents were not affected by the presence of skeletal-muscle troponin I in the blood and may be useful for routine examinations.

  8. High Sensitivity Combined with Extended Structural Coverage of Labile Compounds via Nanoelectrospray Ionization at Subambient Pressures

    DOE PAGES

    Cox, Jonathan T.; Kronewitter, Scott R.; Shukla, Anil K.; ...

    2014-09-15

    Subambient pressure ionization with nanoelectrospray (SPIN) has proven to be effective in producing ions with high efficiency and transmitting them to low pressures for high sensitivity mass spectrometry (MS) analysis. Here we present evidence that not only does the SPIN source improve MS sensitivity but also allows for gentler ionization conditions. The gentleness of a conventional heated capillary electrospray ionization (ESI) source and the SPIN source was compared by the liquid chromatography mass spectrometry (LC-MS) analysis of colominic acid. Colominic acid is a mixture of sialic acid polymers of different lengths containing labile glycosidic linkages between monomer units necessitating amore » gentle ion source. By coupling the SPIN source with high resolution mass spectrometry and using advanced data processing tools, we demonstrate much extended coverage of sialic acid polymer chains as compared to using the conventional ESI source. Additionally we show that SPIN-LC-MS is effective in elucidating polymer features with high efficiency and high sensitivity previously unattainable by the conventional ESI-LC-MS methods.« less

  9. Food intake is influenced by sensory sensitivity.

    PubMed

    Naish, Katherine R; Harris, Gillian

    2012-01-01

    Wide availability of highly palatable foods is often blamed for the rising incidence of obesity. As palatability is largely determined by the sensory properties of food, this study investigated how sensitivity to these properties affects how much we eat. Forty females were classified as either high or low in sensory sensitivity based on their scores on a self-report measure of sensory processing (the Adult Sensory Profile), and their intake of chocolate during the experiment was measured. Food intake was significantly higher for high-sensitivity compared to low-sensitivity individuals. Furthermore, individual scores of sensory sensitivity were positively correlated with self-reported emotional eating. These data could indicate that individuals who are more sensitive to the sensory properties of food have a heightened perception of palatability, which, in turn, leads to a greater food intake.

  10. Two-channel highly sensitive sensors based on 4 × 4 multimode interference couplers

    NASA Astrophysics Data System (ADS)

    Le, Trung-Thanh

    2017-12-01

    We propose a new kind of microring resonators (MRR) based on 4 × 4 multimode interference (MMI) couplers for multichannel and highly sensitive chemical and biological sensors. The proposed sensor structure has advantages of compactness and high sensitivity compared with the reported sensing structures. By using the transfer matrix method (TMM) and numerical simulations, the designs of the sensor based on silicon waveguides are optimized and demonstrated in detail. We apply our structure to detect glucose and ethanol concentrations simultaneously. A high sensitivity of 9000 nm/RIU, detection limit of 2 × 10‒4 for glucose sensing and sensitivity of 6000 nm/RIU, detection limit of 1.3 × 10‒5 for ethanol sensing are achieved.

  11. The metabolic phenotype of Prader-Willi syndrome (PWS) in childhood: heightened insulin sensitivity relative to body mass index.

    PubMed

    Haqq, Andrea M; Muehlbauer, Michael J; Newgard, Christopher B; Grambow, Steven; Freemark, Michael

    2011-01-01

    Insulin sensitivity is higher in patients with Prader-Willi syndrome (PWS) than in body mass index-matched obese controls (OCs). Factors contributing to the heightened insulin sensitivity of PWS remain obscure. We compared the fasting levels of various hormones, cytokines, lipids, and liver function tests in 14 PWS patients and 14 OCs with those in 14 age- and gender-matched lean children (LC). We hypothesized that metabolic profiles of children with PWS are comparable with those of LC, but different from those of OCs. Leptin levels were comparable in PWS patients and OCs, suggesting comparable degrees of adiposity. Glucose levels were comparable among groups. However, fasting insulin concentrations and homeostasis model assessment insulin resistance index were lower in PWS patients than in OCs (P < 0.05) and similar to LC. Moreover, high-density lipoprotein levels were lower and triglycerides higher in OCs (P < 0.05) but not PWS patients. Total adiponectin, high-molecular-weight (HMW) adiponectin and the HMW to total adiponectin ratio were higher in PWS patients (P < 0.05) than in OCs and similar to LC. High-sensitivity C-reactive protein and IL-6 levels were higher in OCs than in PWS patients or LC (P < 0.05). Nevertheless, PAI-1 levels were elevated in both OC and PWS patients. There were no group differences in glucagon-like peptide-1, macrophage chemoattractant protein-1, TNFα, IL-2, IL-8, IL-10, IL-12p40, IL-18, resistin, total or low-density lipoprotein cholesterol, aspartate aminotransferase, or alanine aminotransferase. The heightened insulin sensitivity of PWS patients relative to OCs is associated with higher levels of adiponectin and lower levels of high-sensitivity C-reactive protein and IL-6. Future studies will determine whether PWS children are protected from obesity comorbidities such as type 2 diabetes, hyperlipidemia, and nonalcoholic fatty liver disease.

  12. Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats

    PubMed Central

    McGuire, Blaine A.; Baladi, Michelle G.; France, Charles P.

    2011-01-01

    Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1–10 mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. PMID:21371470

  13. Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats.

    PubMed

    McGuire, Blaine A; Baladi, Michelle G; France, Charles P

    2011-05-11

    Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1-10mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Interoceptive threat leads to defensive mobilization in highly anxiety sensitive persons.

    PubMed

    Melzig, Christiane A; Holtz, Katharina; Michalowski, Jaroslaw M; Hamm, Alfons O

    2011-06-01

    To study defensive mobilization elicited by the exposure to interoceptive arousal sensations, we exposed highly anxiety sensitive students to a symptom provocation task. Symptom reports, autonomic arousal, and the startle eyeblink response were monitored during guided hyperventilation and a recovery period in 26 highly anxiety sensitive persons and 22 controls. Normoventilation was used as a non-provocative comparison condition. Hyperventilation led to autonomic arousal and a marked increase in somatic symptoms. While high and low anxiety sensitive persons did not differ in their defensive activation during hyperventilation, group differences were detected during early recovery. Highly anxiety sensitive students exhibited a potentiation of startle response magnitudes and increased autonomic arousal after hyper- as compared to after normoventilation, indicating defensive mobilization evoked by the prolonged presence of feared somatic sensations. Copyright © 2010 Society for Psychophysiological Research.

  15. Sensitivity Analysis of Multidisciplinary Rotorcraft Simulations

    NASA Technical Reports Server (NTRS)

    Wang, Li; Diskin, Boris; Biedron, Robert T.; Nielsen, Eric J.; Bauchau, Olivier A.

    2017-01-01

    A multidisciplinary sensitivity analysis of rotorcraft simulations involving tightly coupled high-fidelity computational fluid dynamics and comprehensive analysis solvers is presented and evaluated. An unstructured sensitivity-enabled Navier-Stokes solver, FUN3D, and a nonlinear flexible multibody dynamics solver, DYMORE, are coupled to predict the aerodynamic loads and structural responses of helicopter rotor blades. A discretely-consistent adjoint-based sensitivity analysis available in FUN3D provides sensitivities arising from unsteady turbulent flows and unstructured dynamic overset meshes, while a complex-variable approach is used to compute DYMORE structural sensitivities with respect to aerodynamic loads. The multidisciplinary sensitivity analysis is conducted through integrating the sensitivity components from each discipline of the coupled system. Numerical results verify accuracy of the FUN3D/DYMORE system by conducting simulations for a benchmark rotorcraft test model and comparing solutions with established analyses and experimental data. Complex-variable implementation of sensitivity analysis of DYMORE and the coupled FUN3D/DYMORE system is verified by comparing with real-valued analysis and sensitivities. Correctness of adjoint formulations for FUN3D/DYMORE interfaces is verified by comparing adjoint-based and complex-variable sensitivities. Finally, sensitivities of the lift and drag functions obtained by complex-variable FUN3D/DYMORE simulations are compared with sensitivities computed by the multidisciplinary sensitivity analysis, which couples adjoint-based flow and grid sensitivities of FUN3D and FUN3D/DYMORE interfaces with complex-variable sensitivities of DYMORE structural responses.

  16. High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Tingting; Zhao, Jing, E-mail: zhaojing-8239@jlu.edu.cn; Peter Grünberg Institute

    2014-11-15

    In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2more » fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.« less

  17. Noise sensitivity: Symptoms, health status, illness behavior and co-occurring environmental sensitivities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baliatsas, Christos, E-mail: c.baliatsas@nivel.nl

    Epidemiological evidence on the symptomatic profile, health status and illness behavior of people with subjective sensitivity to noise is still scarce. Also, it is unknown to what extent noise sensitivity co-occurs with other environmental sensitivities such as multi-chemical sensitivity and sensitivity to electromagnetic fields (EMF). A cross-sectional study performed in the Netherlands, combining self-administered questionnaires and electronic medical records of non-specific symptoms (NSS) registered by general practitioners (GP) allowed us to explore this further. The study sample consisted of 5806 participants, drawn from 21 general practices. Among participants, 722 (12.5%) responded “absolutely agree” to the statement “I am sensitive tomore » noise”, comprising the high noise-sensitive (HNS) group. Compared to the rest of the sample, people in the HNS group reported significantly higher scores on number and duration of self-reported NSS, increased psychological distress, decreased sleep quality and general health, more negative symptom perceptions and higher prevalence of healthcare contacts, GP-registered NSS and prescriptions for antidepressants and benzodiazepines. These results remained robust after adjustment for demographic, residential and lifestyle characteristics, objectively measured nocturnal noise exposure from road-traffic and GP-registered morbidity. Co-occurrence rates with other environmental sensitivities varied between 9% and 50%. Individuals with self-declared sensitivity to noise are characterized by high prevalence of multiple NSS, poorer health status and increased illness behavior independently of noise exposure levels. Findings support the notion that different types of environmental sensitivities partly overlap. - Highlights: • People with self-reported noise sensitivity experience multiple non-specific symptoms. • They also report comparatively poorer health and increased illness behavior. • Co-occurrence with other environmental sensitivities is moderate to high. • Road-traffic noise and GP-registered morbidity did not account for these results.« less

  18. The Sensitivity of Adolescent School-Based Hearing Screens Is Significantly Improved by Adding High Frequencies

    ERIC Educational Resources Information Center

    Sekhar, Deepa L.; Zalewski, Thomas R.; Beiler, Jessica S.; Czarnecki, Beth; Barr, Ashley L.; King, Tonya S.; Paul, Ian M.

    2016-01-01

    High frequency hearing loss (HFHL), often related to hazardous noise, affects one in six U.S. adolescents. Yet, only 20 states include school-based hearing screens for adolescents. Only six states test multiple high frequencies. Study objectives were to (1) compare the sensitivity of state school-based hearing screens for adolescents to gold…

  19. Sensitive high frequency hearing in earless and partially eared harlequin frogs (Atelopus).

    PubMed

    Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A; Hoke, Kim L

    2018-04-19

    Harlequin frogs, genus Atelopus , communicate at high frequencies despite most species lacking a complete tympanic middle ear that facilitates high frequency hearing in most anurans and other tetrapods. Here we test whether Atelopus are better at sensing high frequency acoustic sound compared to other eared and earless species in the Bufonidae family, determine whether middle ear variation within Atelopus affects hearing sensitivity, and test potential hearing mechanisms in Atelopus We determine that at high frequencies (2000-4000 Hz) Atelopus are 10-34 dB more sensitive than other earless bufonids but are relatively insensitive to mid-range frequencies (900-1500 Hz) compared to eared bufonids. Hearing among Atelopus species is fairly consistent, evidence that the partial middle ears present in a subset of Atelopus species do not convey a substantial hearing advantage. We further demonstrate that Atelopus hearing is not likely facilitated by vibration of the skin overlying the normal tympanic membrane region or the body lung wall, leaving the extratympanic hearing pathways in Atelopus enigmatic. Together these results show Atelopus have sensitive high frequency hearing without the aid of a tympanic middle ear and prompt further study of extratympanic hearing mechanisms in anurans. © 2018. Published by The Company of Biologists Ltd.

  20. Experimental demonstration of high sensitivity for silver rectangular grating-coupled surface plasmon resonance (SPR) sensing

    NASA Astrophysics Data System (ADS)

    Dai, Yanqiu; Xu, Huimei; Wang, Haoyu; Lu, Yonghua; Wang, Pei

    2018-06-01

    We experimentally demonstrated a high sensitivity of surface plasmon resonance (SPR) sensor with silver rectangular grating coupling. The reflection spectra of the silver gratings indicated that surface plasmon resonance can be excited by either positive or negative order diffraction of the grating, depending on the period of the gratings. Comparing to prism-coupled SPR sensor, the sensitivities are higher for negative order diffraction coupling in bigger coupling angle, but much smaller for positive order diffraction coupling of the gratings. High sensitivity of 254.13 degree/RIU is experimentally realized by grating-based SPR sensor in the negative diffraction excitation mode. Our work paves the way for compact and sensitive SPR sensor in the applications of biochemical and gas sensing.

  1. Combination of methylated-DNA precipitation and methylation-sensitive restriction enzymes (COMPARE-MS) for the rapid, sensitive and quantitative detection of DNA methylation.

    PubMed

    Yegnasubramanian, Srinivasan; Lin, Xiaohui; Haffner, Michael C; DeMarzo, Angelo M; Nelson, William G

    2006-02-09

    Hypermethylation of CpG island (CGI) sequences is a nearly universal somatic genome alteration in cancer. Rapid and sensitive detection of DNA hypermethylation would aid in cancer diagnosis and risk stratification. We present a novel technique, called COMPARE-MS, that can rapidly and quantitatively detect CGI hypermethylation with high sensitivity and specificity in hundreds of samples simultaneously. To quantitate CGI hypermethylation, COMPARE-MS uses real-time PCR of DNA that was first digested by methylation-sensitive restriction enzymes and then precipitated by methyl-binding domain polypeptides immobilized on a magnetic solid matrix. We show that COMPARE-MS could detect five genome equivalents of methylated CGIs in a 1000- to 10,000-fold excess of unmethylated DNA. COMPARE-MS was used to rapidly quantitate hypermethylation at multiple CGIs in >155 prostate tissues, including benign and malignant prostate specimens, and prostate cell lines. This analysis showed that GSTP1, MDR1 and PTGS2 CGI hypermethylation as determined by COMPARE-MS could differentiate between malignant and benign prostate with sensitivities >95% and specificities approaching 100%. This novel technology could significantly improve our ability to detect CGI hypermethylation.

  2. Coupled Aerodynamic and Structural Sensitivity Analysis of a High-Speed Civil Transport

    NASA Technical Reports Server (NTRS)

    Mason, B. H.; Walsh, J. L.

    2001-01-01

    An objective of the High Performance Computing and Communication Program at the NASA Langley Research Center is to demonstrate multidisciplinary shape and sizing optimization of a complete aerospace vehicle configuration by using high-fidelity, finite-element structural analysis and computational fluid dynamics aerodynamic analysis. In a previous study, a multi-disciplinary analysis system for a high-speed civil transport was formulated to integrate a set of existing discipline analysis codes, some of them computationally intensive, This paper is an extension of the previous study, in which the sensitivity analysis for the coupled aerodynamic and structural analysis problem is formulated and implemented. Uncoupled stress sensitivities computed with a constant load vector in a commercial finite element analysis code are compared to coupled aeroelastic sensitivities computed by finite differences. The computational expense of these sensitivity calculation methods is discussed.

  3. High-frequency phase shift measurement greatly enhances the sensitivity of QCM immunosensors.

    PubMed

    March, Carmen; García, José V; Sánchez, Ángel; Arnau, Antonio; Jiménez, Yolanda; García, Pablo; Manclús, Juan J; Montoya, Ángel

    2015-03-15

    In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of a new electronic characterization approach based on phase change measurements at a constant fixed frequency, a highly sensitive and versatile high fundamental frequency (HFF) QCM immunosensor has successfully been developed and tested for its use in pesticide (carbaryl and thiabendazole) analysis. The analytical performance of several immunosensors was compared in competitive immunoassays taking carbaryl insecticide as the model analyte. The highest sensitivity was exhibited by the 100MHz HFF-QCM carbaryl immunosensor. When results were compared with those reported for 9MHz QCM, analytical parameters clearly showed an improvement of one order of magnitude for sensitivity (estimated as the I50 value) and two orders of magnitude for the limit of detection (LOD): 30μgl(-1) vs 0.66μgL(-1)I50 value and 11μgL(-1) vs 0.14μgL(-1) LOD, for 9 and 100MHz, respectively. For the fungicide thiabendazole, I50 value was roughly the same as that previously reported for SPR under the same biochemical conditions, whereas LOD improved by a factor of 2. The analytical performance achieved by high frequency QCM immunosensors surpassed those of conventional QCM and SPR, closely approaching the most sensitive ELISAs. The developed 100MHz QCM immunosensor strongly improves sensitivity in biosensing, and therefore can be considered as a very promising new analytical tool for in liquid applications where highly sensitive detection is required. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Transport pilot workload - A comparison of two subjective techniques

    NASA Technical Reports Server (NTRS)

    Battiste, Vernol; Bortolussi, Michael

    1988-01-01

    Although SWAT and NASA-TLX workload scales have been compared on numerous occasions, they have not been compared in the context of transport operations. Transport pilot workload has traditionally been classified as long periods of low workload with occasional spikes of high workload. Thus, the relative sensitivity of the scales to variations in workload at the low end of the scale were evaluated. This study was a part of a larger study which investigated workload measures for aircraft certification, conducted in a Phase II certified Link/Boeing 727 simulator. No significant main effects were found for any performance-based measures of workload. However, both SWAT and NASA-TLX were sensitive to differences between high and low workload flights and to differences among flight segments. NASA-TLX (but not SWAT) was sensitive to the increase in workload during the cruise segment of the high workload flight. Between-subject variability was high for SWAT. NASA-TLX was found to be stable when compared in the test/retest paradigm. A test/retest by segment interaction suggested that this was not the case for SWAT ratings.

  5. Perturbed length-dependent activation in human hypertrophic cardiomyopathy with missense sarcomeric gene mutations.

    PubMed

    Sequeira, Vasco; Wijnker, Paul J M; Nijenkamp, Louise L A M; Kuster, Diederik W D; Najafi, Aref; Witjas-Paalberends, E Rosalie; Regan, Jessica A; Boontje, Nicky; Ten Cate, Folkert J; Germans, Tjeerd; Carrier, Lucie; Sadayappan, Sakthivel; van Slegtenhorst, Marjon A; Zaremba, Ruud; Foster, D Brian; Murphy, Anne M; Poggesi, Corrado; Dos Remedios, Cris; Stienen, Ger J M; Ho, Carolyn Y; Michels, Michelle; van der Velden, Jolanda

    2013-05-24

    High-myofilament Ca(2+) sensitivity has been proposed as a trigger of disease pathogenesis in familial hypertrophic cardiomyopathy (HCM) on the basis of in vitro and transgenic mice studies. However, myofilament Ca(2+) sensitivity depends on protein phosphorylation and muscle length, and at present, data in humans are scarce. To investigate whether high myofilament Ca(2+) sensitivity and perturbed length-dependent activation are characteristics for human HCM with mutations in thick and thin filament proteins. Cardiac samples from patients with HCM harboring mutations in genes encoding thick (MYH7, MYBPC3) and thin (TNNT2, TNNI3, TPM1) filament proteins were compared with sarcomere mutation-negative HCM and nonfailing donors. Cardiomyocyte force measurements showed higher myofilament Ca(2+) sensitivity in all HCM samples and low phosphorylation of protein kinase A (PKA) targets compared with donors. After exogenous PKA treatment, myofilament Ca(2+) sensitivity was similar (MYBPC3mut, TPM1mut, sarcomere mutation-negative HCM), higher (MYH7mut, TNNT2mut), or even significantly lower (TNNI3mut) compared with donors. Length-dependent activation was significantly smaller in all HCM than in donor samples. PKA treatment increased phosphorylation of PKA-targets in HCM myocardium and normalized length-dependent activation to donor values in sarcomere mutation-negative HCM and HCM with truncating MYBPC3 mutations but not in HCM with missense mutations. Replacement of mutant by wild-type troponin in TNNT2mut and TNNI3mut corrected length-dependent activation to donor values. High-myofilament Ca(2+) sensitivity is a common characteristic of human HCM and partly reflects hypophosphorylation of PKA targets compared with donors. Length-dependent sarcomere activation is perturbed by missense mutations, possibly via posttranslational modifications other than PKA hypophosphorylation or altered protein-protein interactions, and represents a common pathomechanism in HCM.

  6. Macular Diagnostic Ability in OCT for Assessing Glaucoma in High Myopia.

    PubMed

    Hung, Kuo-Chi; Wu, Pei-Chang; Poon, Yi-Chieh; Chang, Hsueh-Wen; Lai, Ing-Chou; Tsai, Jen-Chia; Lin, Pei-Wen; Teng, Mei-Ching

    2016-02-01

    To compare the diagnostic abilities of spectral-domain optical coherence tomography (SD-OCT; Spectralis OCT) and time-domain OCT (TD-OCT; Stratus OCT). Changes in macular parameters in highly myopic eyes of glaucoma patients and highly myopic eyes of glaucoma suspects were evaluated and compared. We collected data from 72 highly myopic eyes (spherical equivalent, ≤-6.0D). Forty-one eyes had perimetric glaucoma and 31 eyes were suspected to have glaucoma (control group). All eyes underwent SD-OCT and TD-OCT imaging. Area under the receiver operating characteristic (AUROC) curve and sensitivity were examined on macular volume and thickness parameters at a fixed specificity and compared between groups. The highest TD-OCT AUROC curves were found using outer inferior sector macular thickness (AUROC curve, 0.911) and volume (AUROC curve, 0.909). The highest SD-OCT AUROC curves were found using outer inferior region thickness (AUROC curve, 0.836) and volume (AUROC curve, 0.834). The difference between the two imaging modalities was not statistically significant (thickness, p = 0.141; volume, p = 0.138). The sensitivity of TD-OCT macular outer inferior average thickness was highest and was 88.2%, with a specificity of 80.4%. The sensitivity of TD-OCT average volume measurements in this same region was 76.5%, with a specificity of 91.3%. The SD-OCT average thickness measurements also had the highest sensitivity in this region, which was 78.6%, with a specificity of 82.1%. The SD-OCT volume measurements had a sensitivity of 67.9%, with a specificity of 92.3%. Both SD-OCT and TD-OCT measurements of outer inferior macular thickness and volume can differentiate between eyes of glaucoma patients and glaucoma suspects with high myopia. These independent predictors all had good sensitivity. Based on our results, SD-OCT and TD-OCT have similar diagnostic abilities. These parameters may provide useful additional data in highly myopic eyes to complement standard glaucoma diagnosis tools.

  7. Comparison of Self-Reported Telephone Interviewing and Web-Based Survey Responses: Findings From the Second Australian Young and Well National Survey

    PubMed Central

    Davenport, Tracey A; Burns, Jane M; Hickie, Ian B

    2017-01-01

    Background Web-based self-report surveying has increased in popularity, as it can rapidly yield large samples at a low cost. Despite this increase in popularity, in the area of youth mental health, there is a distinct lack of research comparing the results of Web-based self-report surveys with the more traditional and widely accepted computer-assisted telephone interviewing (CATI). Objective The Second Australian Young and Well National Survey 2014 sought to compare differences in respondent response patterns using matched items on CATI versus a Web-based self-report survey. The aim of this study was to examine whether responses varied as a result of item sensitivity, that is, the item’s susceptibility to exaggeration on underreporting and to assess whether certain subgroups demonstrated this effect to a greater extent. Methods A subsample of young people aged 16 to 25 years (N=101), recruited through the Second Australian Young and Well National Survey 2014, completed the identical items on two occasions: via CATI and via Web-based self-report survey. Respondents also rated perceived item sensitivity. Results When comparing CATI with the Web-based self-report survey, a Wilcoxon signed-rank analysis showed that respondents answered 14 of the 42 matched items in a significantly different way. Significant variation in responses (CATI vs Web-based) was more frequent if the item was also rated by the respondents as highly sensitive in nature. Specifically, 63% (5/8) of the high sensitivity items, 43% (3/7) of the neutral sensitivity items, and 0% (0/4) of the low sensitivity items were answered in a significantly different manner by respondents when comparing their matched CATI and Web-based question responses. The items that were perceived as highly sensitive by respondents and demonstrated response variability included the following: sexting activities, body image concerns, experience of diagnosis, and suicidal ideation. For high sensitivity items, a regression analysis showed respondents who were male (beta=−.19, P=.048) or who were not in employment, education, or training (NEET; beta=−.32, P=.001) were significantly more likely to provide different responses on matched items when responding in the CATI as compared with the Web-based self-report survey. The Web-based self-report survey, however, demonstrated some evidence of avidity and attrition bias. Conclusions Compared with CATI, Web-based self-report surveys are highly cost-effective and had higher rates of self-disclosure on sensitive items, particularly for respondents who identify as male and NEET. A drawback to Web-based surveying methodologies, however, includes the limited control over avidity bias and the greater incidence of attrition bias. These findings have important implications for further development of survey methods in the area of health and well-being, especially when considering research topics (in this case diagnosis, suicidal ideation, sexting, and body image) and groups that are being recruited (young people, males, and NEET). PMID:28951382

  8. Highly Sensitive Droplet Digital PCR Method for Detection of EGFR-Activating Mutations in Plasma Cell-Free DNA from Patients with Advanced Non-Small Cell Lung Cancer.

    PubMed

    Zhu, Guanshan; Ye, Xin; Dong, Zhengwei; Lu, Ya Chao; Sun, Yun; Liu, Yi; McCormack, Rose; Gu, Yi; Liu, Xiaoqing

    2015-05-01

    Epidermal growth factor receptor (EGFR) mutation testing in plasma cell-free DNA from lung cancer patients is an emerging clinical tool. However, compared with tissue testing, the sensitivity of plasma testing is not yet satisfactory because of the highly fragmented nature of plasma cell-free DNA, low fraction of tumor DNA, and limitations of available detection technologies. We therefore developed a highly sensitive and specific droplet digital PCR method for plasma EGFR mutation (exon19 deletions and L858R) testing. Plasma from 86 EGFR-tyrosine kinase inhibitor-naive lung cancer patients was tested and compared with EGFR mutation status of matched tumor tissues tested by amplification refractory mutation system. By using EGFR mutation-positive cell DNA, we optimized the droplet digital PCR assays to reach 0.04% sensitivity. The plasma testing sensitivity and specificity, compared with the matched tumor tissues tested by amplification refractory mutation system, were 81.82% (95% CI, 59.72%-94.81%) and 98.44% (95% CI, 91.60%-99.96%), respectively, for exon19 deletions, with 94.19% concordance rate (κ = 0.840; 95% CI, 0.704-0.976; P < 0.0001), whereas they were 80.00% (95% CI, 51.91%-95.67%) and 95.77% (95% CI, 88.14%-99.12%), respectively, for L858R, with 93.02% concordance rate (κ = 0.758; 95% CI, 0.571-0.945; P < 0.0001). The reported highly sensitive and specific droplet digital PCR assays for EGFR mutation detection have potential in clinical blood testing. Copyright © 2015 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  9. Enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence.

    PubMed Central

    Crouch, C F

    1995-01-01

    AIMS--To evaluate the clinical performance of enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence. METHODS--Classification of routine clinical samples from the originating laboratories was compared with that obtained using the chemiluminescence based assays. Resolution of discordant results was achieved by testing in alternative enzyme immunoassays (IgM) or by an independent laboratory using the dye test (IgG). RESULTS--Compared with resolved data, the IgM assay was found to be highly specific (100%) with a cut off selected to give optimal performance with respect to both the early detection of specific IgM and the detection of persistent levels of specific IgM (sensitivity 98%). Compared with resolved data, the IgG assay was shown to have a sensitivity and a specificity of 99.4%. CONCLUSIONS--The Amerlite Toxo IgM assay possesses high levels of sensitivity and specificity. Assay interference due to rheumatoid factor like substances is not a problem. The Amerlite Toxo IgG assay possesses good sensitivity and specificity, but is less sensitive for the detection of seroconversion than methods detecting both IgG and IgM. PMID:7560174

  10. Use of an Antecedent Analysis and a Force Sensitive Platform to Compare Stereotyped Movements and Motor Tics

    ERIC Educational Resources Information Center

    Crosland, Kimberly A.; Zarcone, Jennifer R.; Schroeder, Stephen; Zarcane, Troy; Fowler, Stephen

    2005-01-01

    Stereotyped movements displayed by 6 participants and tics displayed by 6 children were evaluated using an antecedent behavioral analysis and a force sensitive platform. We found that tics occurred more often in an alone condition when compared to high preference toy and play conditions, whereas stereotyped movements were more variable across…

  11. High sensitivity boundary layer transition detector

    NASA Technical Reports Server (NTRS)

    Azzazy, M.; Modarress, D.; Hoeft, T.

    1985-01-01

    A high sensitivity differential interferometer has been developed to locate the region where the boundary layer flow changes from laminar to turbulent. Two experimental configurations have been used to evaluate the performance of the interferometer, open shear layer configuration and wind tunnel turbulent spot configuration. In each experiment small temperature fluctuations were introduced as the signal source. Simultaneous cold wire measurements have been compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations in the order of .001 the laser wavelength.

  12. Sensitivity to apomorphine-induced yawning and hypothermia in rats eating standard or high-fat chow.

    PubMed

    Baladi, Michelle G; Thomas, Yvonne M; France, Charles P

    2012-07-01

    Feeding conditions modify sensitivity to indirect- and direct-acting dopamine receptor agonists as well as the development of sensitization to these drugs. This study examined whether feeding condition affects acute sensitivity to apomorphine-induced yawning or changes in sensitivity that occur over repeated drug administration. Quinpirole-induced yawning was also evaluated to see whether sensitization to apomorphine confers cross-sensitization to quinpirole. Drug-induced yawning was measured in different groups of male Sprague Dawley rats (n = 6/group) eating high (34.3%) fat or standard (5.7% fat) chow. Five weeks of eating high-fat chow rendered otherwise drug-naïve rats more sensitive to apomorphine- (0.01-1.0 mg/kg, i.p.) and quinpirole- (0.0032-0.32 mg/kg, i.p.) induced yawning, compared with rats eating standard chow. In other rats, tested weekly with apomorphine, sensitivity to apomorphine-induced yawning increased (sensitization) similarly in rats with free access to standard or high-fat chow; conditioning to the testing environment appeared to contribute to increased yawning in both groups of rats. Food restriction decreased sensitivity to apomorphine-induced yawning across five weekly tests. Rats with free access to standard or high-fat chow and sensitized to apomorphine were cross-sensitized to quinpirole-induced yawning. The hypothermic effects of apomorphine and quinpirole were not different regardless of drug history or feeding condition. Eating high-fat chow or restricting access to food alters sensitivity to direct-acting dopamine receptor agonists (apomorphine, quinpirole), although the relative contribution of drug history and dietary conditions to sensitivity changes appears to vary among agonists.

  13. An evaluation of the diagnostic accuracy of the 1991 American College of Chest Physicians/Society of Critical Care Medicine and the 2001 Society of Critical Care Medicine/European Society of Intensive Care Medicine/American College of Chest Physicians/American Thoracic Society/Surgical Infection Society sepsis definition.

    PubMed

    Zhao, Huifang; Heard, Stephen O; Mullen, Marie T; Crawford, Sybil; Goldberg, Robert J; Frendl, Gyorgy; Lilly, Craig M

    2012-06-01

    Limited research has been conducted to compare the test characteristics of the 1991 and 2001 sepsis consensus definitions. This study assessed the accuracy of the two sepsis consensus definitions among adult critically ill patients compared to sepsis case adjudication by three senior clinicians. Observational study of patients admitted to intensive care units. Seven intensive care units of an academic medical center. A random sample of 960 patients from all adult intensive care unit patients between October 2007 and December 2008. None. Sensitivity, specificity, and the area under the receiver operating characteristic curve for the two consensus definitions were calculated by comparing the number of patients who met or did not meet consensus definitions vs. the number of patients who were or were not diagnosed with sepsis by adjudication. The 1991 sepsis definition had a high sensitivity of 94.6%, but a low specificity of 61.0%. The 2001 sepsis definition had a slightly increased sensitivity but a decreased specificity, which were 96.9% and 58.3%, respectively. The areas under the receiver operating characteristic curve for the two definitions were not statistically different (0.778 and 0.776, respectively). The sensitivities and areas under the receiver operating characteristic curve of both definitions were lower at the 24-hr time window level than those of the intensive care unit stay level, though their specificities increased slightly. Fever, high white blood cell count or immature forms, low Glasgow coma score, edema, positive fluid balance, high cardiac index, low PaO2/FIO2 ratio, and high levels of creatinine and lactate were significantly associated with sepsis by both definitions and adjudication. Both the 1991 and the 2001 sepsis definition have a high sensitivity but low specificity; the 2001 definition has a slightly increased sensitivity but a decreased specificity compared to the 1991 definition. The diagnostic performances of both definitions were suboptimal. A parsimonious set of significant predictors for sepsis diagnosis is likely to improve current sepsis case definitions.

  14. High-sensitivity detection of biological amines using fast Hadamard transform CE coupled with photolytic optical gating.

    PubMed

    Braun, Kevin L; Hapuarachchi, Suminda; Fernandez, Facundo M; Aspinwall, Craig A

    2007-08-01

    Here, we report the first utilization of Hadamard transform CE (HTCE), a high-sensitivity, multiplexed CE technique, with photolytic optical gating sample injection of caged fluorescent labels for the detection of biologically important amines. Previous implementations of HTCE have relied upon photobleaching optical gating sample injection of fluorescent dyes. Photolysis of caged fluorescent labels reduces the fluorescence background, providing marked enhancements in sensitivity compared to photobleaching. Application of fast Hadamard transform CE (fHTCE) for fluorescein-based dyes yields a ten-fold higher sensitivity for photolytic injections compared to photobleaching injections, due primarily to the reduced fluorescent background provided by caged fluorescent dyes. Detection limits as low as 5 pM (ca. 18 molecules per injection event) were obtained with on-column LIF detection using fHTCE in less than 25 s, with the capacity for continuous, online separations. Detection limits for glutamate and aspartate below 150 pM (1-2 amol/injection event) were obtained using photolytic sample injection, with separation efficiencies exceeding 1 x 10(6) plates/m and total multiplexed separation times as low as 8 s. These results strongly support the feasibility of this approach for high-sensitivity dynamic chemical monitoring applications.

  15. Development and application of a marine sediment pore-water toxicity test using Ulva fasciata zoospores

    USGS Publications Warehouse

    Hooten, Russell L.; Carr, R. Scott

    1998-01-01

    An acute (96 h) pore-water toxicity test protocol using germination and growth of Ulva fasciatazoospores as endpoints was developed to test the toxicity of marine and estuarine sediment pore-water samples. Tests with an organic toxicant (sodium dodecyl sulfate; SDS), three metals (Cd, Cu, and Zn), and ammonia (NH3) were conducted to determine zoospore sensitivity. Zoospore germination and gametophyte growth were as sensitive to SDS as sea urchin (Arbacia punctulata) fertilization and embryological development. Zoospore sensitivity to metals was greater than or comparable to that of adult macroalgae. Zoospores were less sensitive to NH3than were other commonly used toxicity test organisms. Test results using this algal assay with sediment pore-water samples with high NH3 concentrations were compared with results from sea urchin fertilization and embryological development tests for the same samples. Ulva fasciatazoospore germination was not affected by samples with high NH3 concentrations that were toxic in both sea urchin tests. Zoospore tolerance of NH3 and sensitivity to other contaminants indicate that their response may be useful in toxicity identification evaluation studies with pore-water samples that contain high concentrations of unionized NH3.

  16. In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla.

    PubMed

    Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart

    2015-03-01

    Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1(-)) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla

    NASA Astrophysics Data System (ADS)

    Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart

    2015-03-01

    Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1-) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI.

  18. High intensity interval training is associated with greater impact on physical fitness, insulin sensitivity and muscle mitochondrial content in males with overweight/obesity, as opposed to continuous endurance training: a randomized controlled trial.

    PubMed

    De Strijcker, Dorien; Lapauw, Bruno; Ouwens, D Margriet; Van de Velde, Dominique; Hansen, Dominique; Petrovic, Mirko; Cuvelier, Claude; Tonoli, Cajsa; Calders, Patrick

    2018-06-01

    To evaluate the effect of high intensity training (HIT) on physical fitness, basal respiratory exchange ratio (bRER), insulin sensitivity and muscle histology in overweight/obese men compared to continuous aerobic training (CAT). 16 male participants with overweight/obesity (age: 42-57 years, body mass index: 28-36 kg/m2) were randomized to HIT (n=8) or CAT (n=8) for 10 weeks, twice a week. HIT was composed of 10 minutes high intensity, 10 minutes continuous aerobic, 10 minutes high intensity exercises. CAT was composed of three times 10 minutes continuous exercising. Changes in anthropometry, physical and metabolic fitness were evaluated. Muscle histology (mitochondria and lipid content) was evaluated by transmission electron microscopy (TEM). HIT showed a significant increase for peak VO2 (P=0.01), for insulin sensitivity (AUC glucose (P<0,001), AUC insulin (P<0,001), OGTT composite score (P=0.007)) and a significant decrease of bRER (P<0.001) compared to CAT. Muscle mitochondrial content was significantly increased after HIT at the subsarcolemmal (P=0.004 number and P=0.001 surface) as well as the intermyofibrillar site (P<0.001 number and P=0.001 surface). High intensity training elicits stronger beneficial effects on physical fitness, basal RER, insulin sensitivity, and muscle mitochondrial content, as compared to continuous aerobic training.

  19. Synthesis and Characterization of CuO Nanodisks for High-Sensitive and Selective Ethanol Gas Sensor Applications.

    PubMed

    Umar, Ahmad; Lee, Jong-Heun; Kumar, Rajesh; Al-Dossary, O

    2017-02-01

    Herein, the fabrication and characterization of highly sensitive and selective ethanol gas sensor based on CuO nanodisks is reported. The CuO nanodisks were synthesized by facile hydrothermal process and detailed characterization revealed the well-crystallinity, high-purity and high density growth of the prepared material. To fabricate the ethanol gas sensor, the prepared nanodisks were coated on alumina substrate. The fabricated sensor exhibited high-sensitivity and the recorded gas response (resistance-ratio), response time (τ res) and recovery time (τ recov) were 6.2, 119 and 35 s, respectively for 100 ppm of C₂H₅OH at 300 °C. Further, the fabricated sensor shows high selectivity towards ethanol gas compared to H₂ and CO gases.

  20. A high-sensitivity temperature sensor based on Sagnac interferometer employing photonic crystal fiber fully filled with ethanol

    NASA Astrophysics Data System (ADS)

    Shi, Min; Li, Shuguang; Chen, Hailiang

    2018-06-01

    A high-sensitivity temperature sensor based on photonic crystal fiber Sagnac interferometer is proposed and studied. All holes of the PCF are filled with ethanol with capillarity. The cladding air holes are uniform arrangements. The two air holes around the core are removed to form new core modes with high birefringence. The sensitivities of the temperature can be up to -8.7657 and 16.8142 nm/°C when temperature rises from 45 to 75 °C and the fiber length is 5.05 cm. And when temperature rises from 10 to 45 °C, the sensitivity can reach -7.848 and 16.655 nm/°C with fiber length 2.11 cm. The performance of the selective-filled and the fully-filled PCF with temperature from 45 to 75 °C and fiber length 5.05 cm are analyzed and compared. The fully filling can better achieve PCF's sensing performance. The simple structure and high sensitivities make the temperature sensor easy to achieve. The temperature sensor with high sensitivities and good linearity has great application value for environmental temperature detecting.

  1. Temperament, character and anxiety sensitivity in panic disorder: a high-risk study.

    PubMed

    Perna, Giampaolo; di Pasquale, Danila; Grassi, Massimiliano; Vanni, Giovanna; Bellodi, Laura; Caldirola, Daniela

    2012-01-01

    Adult patients with panic disorder (PD) show high levels of harm avoidance and anxiety sensitivity. Peculiar temperament profiles and high anxiety sensitivity have been proposed as developmental risk factors for PD in adult age. Since familial-genetic influences play a role both in PD and in anxiety sensitivity and temperament profiles, this study aims to investigate the possible association between family history of PD and peculiar temperament-character profiles or high anxiety sensitivity in offspring of patients with PD. Thirty-four children of patients with PD with/without agoraphobia and 30 children of healthy subjects were compared. Temperament and character dimensions and anxiety sensitivity levels of children were obtained by the Junior Temperament and Character Inventory and the Childhood Anxiety Sensitivity Index. Children of patients with PD and children of healthy subjects differed neither in temperament and character dimensions nor in anxiety sensitivity levels. Our results show that family history of PD is not associated with peculiar temperament and character profiles or high anxiety sensitivity in children, suggesting that these factors may not be early expressions of familial vulnerability to PD. Since the sample is small and the study has a cross-sectional design, longitudinal studies in larger samples are warranted to confirm these findings and to clarify the role of anxiety sensitivity and temperament-character dimensions in the development of PD. Copyright © 2012 S. Karger AG, Basel.

  2. High sensitivity knitted fabric strain sensors

    NASA Astrophysics Data System (ADS)

    Xie, Juan; Long, Hairu; Miao, Menghe

    2016-10-01

    Wearable sensors are increasingly used in smart garments for detecting and transferring vital signals and body posture, movement and respiration. Existing fabric strain sensors made from metallized yarns have low sensitivity, poor comfort and low durability to washing. Here we report a knitted fabric strain sensor made from a cotton/stainless steel (SS) fibre blended yarn which shows much higher sensitivity than sensors knitted from metallized yarns. The fabric feels softer than pure cotton textiles owing to the ultrafine stainless steel fibres and does not lose its electrical property after washing. The reason for the high sensitivity of the cotton/SS knitted fabric sensor was explored by comparing its sensing mechanism with the knitted fabric sensor made from metallized yarns. The results show that the cotton/SS yarn-to-yarn contact resistance is highly sensitive to strain applied to hooked yarn loops.

  3. A high-efficiency HPGe coincidence system for environmental analysis.

    PubMed

    Britton, R; Davies, A V; Burnett, J L; Jackson, M J

    2015-08-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a network of certified laboratories which must meet certain sensitivity requirements for CTBT relevant radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a high-efficiency, dual-detector gamma spectroscopy system has been developed to improve the sensitivity of measurements for treaty compliance, greatly reducing the time required for each sample. Utilising list-mode acquisition, each sample can be counted once, and processed multiple times to further improve sensitivity. For the 8 key radionuclides considered, Minimum Detectable Activities (MDA's) were improved by up to 37% in standard mode (when compared to a typical CTBT detector system), with the acquisition time required to achieve the CTBT sensitivity requirements reduced from 6 days to only 3. When utilising the system in coincidence mode, the MDA for (60) Co in a high-activity source was improved by a factor of 34 when compared to a standard CTBT detector, and a factor of 17 when compared to the dual-detector system operating in standard mode. These MDA improvements will allow the accurate and timely quantification of radionuclides that decay via both singular and cascade γ emission, greatly enhancing the effectiveness of CTBT laboratories. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  4. Niacin Skin Sensitivity Is Increased in Adolescents at Ultra-High Risk for Psychosis

    PubMed Central

    Schäfer, Miriam R.; Milleit, Berko; Langbein, Kerstin; Hipler, Uta-Christina; Milleit, Christine; Klier, Claudia M.; Schlögelhofer, Monika; Holub, Magdalena; Holzer, Ingrid; Berk, Michael; McGorry, Patrick D.; Sauer, Heinrich; Amminger, G. Paul

    2016-01-01

    Background Most studies provide evidence that the skin flush response to nicotinic acid (niacin) stimulation is impaired in schizophrenia. However, only little is known about niacin sensitivity in the ultra-high risk (UHR) phase of psychotic disorders. Methods We compared visual ratings of niacin sensitivity between adolescents at UHR for psychosis according to the one year transition outcome (UHR-T n = 11; UHR-NT n = 55) with healthy controls (HC n = 25) and first episode schizophrenia patients (FEP n = 25) treated with atypical antipsychotics. Results Contrary to our hypothesis niacin sensitivity of the entire UHR group was not attenuated, but significantly increased compared to the HC group, whereas no difference could be found between the UHR-T and UHR-NT groups. As expected, niacin sensitivity of FEP was attenuated compared to HC group. In UHR individuals niacin sensitivity was inversely correlated with omega-6 and -9 fatty acids (FA), but positively correlated with phospholipase A2 (inPLA2) activity, a marker of membrane lipid repair/remodelling. Conclusions Increased niacin sensitivity in UHR states likely indicates an impaired balance of eicosanoids and omega-6/-9 FA at a membrane level. Our findings suggest that the emergence of psychosis is associated with an increased mobilisation of eicosanoids prior to the transition to psychosis possibly reflecting a “pro-inflammatory state”, whereas thereafter eicosanoid mobilisation seems to be attenuated. Potential treatment implications for the UHR state should be further investigated. PMID:26894921

  5. Sensitivity Challenge of Steep Transistors

    NASA Astrophysics Data System (ADS)

    Ilatikhameneh, Hesameddin; Ameen, Tarek A.; Chen, ChinYi; Klimeck, Gerhard; Rahman, Rajib

    2018-04-01

    Steep transistors are crucial in lowering power consumption of the integrated circuits. However, the difficulties in achieving steepness beyond the Boltzmann limit experimentally have hindered the fundamental challenges in application of these devices in integrated circuits. From a sensitivity perspective, an ideal switch should have a high sensitivity to the gate voltage and lower sensitivity to the device design parameters like oxide and body thicknesses. In this work, conventional tunnel-FET (TFET) and negative capacitance FET are shown to suffer from high sensitivity to device design parameters using full-band atomistic quantum transport simulations and analytical analysis. Although Dielectric Engineered (DE-) TFETs based on 2D materials show smaller sensitivity compared with the conventional TFETs, they have leakage issue. To mitigate this challenge, a novel DE-TFET design has been proposed and studied.

  6. Comparison of Self-Reported Telephone Interviewing and Web-Based Survey Responses: Findings From the Second Australian Young and Well National Survey.

    PubMed

    Milton, Alyssa C; Ellis, Louise A; Davenport, Tracey A; Burns, Jane M; Hickie, Ian B

    2017-09-26

    Web-based self-report surveying has increased in popularity, as it can rapidly yield large samples at a low cost. Despite this increase in popularity, in the area of youth mental health, there is a distinct lack of research comparing the results of Web-based self-report surveys with the more traditional and widely accepted computer-assisted telephone interviewing (CATI). The Second Australian Young and Well National Survey 2014 sought to compare differences in respondent response patterns using matched items on CATI versus a Web-based self-report survey. The aim of this study was to examine whether responses varied as a result of item sensitivity, that is, the item's susceptibility to exaggeration on underreporting and to assess whether certain subgroups demonstrated this effect to a greater extent. A subsample of young people aged 16 to 25 years (N=101), recruited through the Second Australian Young and Well National Survey 2014, completed the identical items on two occasions: via CATI and via Web-based self-report survey. Respondents also rated perceived item sensitivity. When comparing CATI with the Web-based self-report survey, a Wilcoxon signed-rank analysis showed that respondents answered 14 of the 42 matched items in a significantly different way. Significant variation in responses (CATI vs Web-based) was more frequent if the item was also rated by the respondents as highly sensitive in nature. Specifically, 63% (5/8) of the high sensitivity items, 43% (3/7) of the neutral sensitivity items, and 0% (0/4) of the low sensitivity items were answered in a significantly different manner by respondents when comparing their matched CATI and Web-based question responses. The items that were perceived as highly sensitive by respondents and demonstrated response variability included the following: sexting activities, body image concerns, experience of diagnosis, and suicidal ideation. For high sensitivity items, a regression analysis showed respondents who were male (beta=-.19, P=.048) or who were not in employment, education, or training (NEET; beta=-.32, P=.001) were significantly more likely to provide different responses on matched items when responding in the CATI as compared with the Web-based self-report survey. The Web-based self-report survey, however, demonstrated some evidence of avidity and attrition bias. Compared with CATI, Web-based self-report surveys are highly cost-effective and had higher rates of self-disclosure on sensitive items, particularly for respondents who identify as male and NEET. A drawback to Web-based surveying methodologies, however, includes the limited control over avidity bias and the greater incidence of attrition bias. These findings have important implications for further development of survey methods in the area of health and well-being, especially when considering research topics (in this case diagnosis, suicidal ideation, sexting, and body image) and groups that are being recruited (young people, males, and NEET). ©Alyssa C Milton, Louise A Ellis, Tracey A Davenport, Jane M Burns, Ian B Hickie. Originally published in JMIR Mental Health (http://mental.jmir.org), 26.09.2017.

  7. Comparison between esophagography and chest computed tomography for evaluation of leaks after esophagectomy and gastric pull-through.

    PubMed

    Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A

    2013-03-01

    To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.

  8. Sensitive skin in Europe.

    PubMed

    Misery, L; Boussetta, S; Nocera, T; Perez-Cullell, N; Taieb, C

    2009-04-01

    Sensitive skin appears as a very frequent condition, but there is no comparative data between countries. To perform an epidemiological approach to skin sensitivity in different European countries. An opinion poll was conducted in eight European countries: Belgium, France, Germany, Greece, Italy, Portugal, Spain and Switzerland. This sample (4506 persons) was drawn from a representative sample of each population aged 15 years or older. Sensitive or very sensitive skin was declared by 38.4% and slightly or not sensitive skin by 61.6%. Women declared more sensitive skin than men. A dermatological disease was declared by 31.2% of people with very sensitive skin, 17.6% of those with sensitive skin, 8.7% of those with slightly sensitive skin and 3.7% of those who do not have sensitive skin. A history of childhood atopic dermatitis was more frequent in patients with sensitive or very sensitive skin. The interviewees who declared that they had dry or oily skin also reported significantly more frequently sensitive or very sensitive skin than those with normal skin. Sensitive and very sensitive skins were clearly more frequent in Italy and France. This study is the first study that compares skin sensitivity in European countries. Prevalence is high, but significant differences are noted between these countries. Dermatological antecedents (or treatments?) could be involved in the occurrence of skin sensitivity.

  9. Multifunctional pH-sensitive superparamagnetic iron-oxide nanocomposites for targeted drug delivery and MR imaging.

    PubMed

    Zhu, Lijuan; Wang, Dali; Wei, Xuan; Zhu, Xinyuan; Li, Jianqi; Tu, Chunlai; Su, Yue; Wu, Jieli; Zhu, Bangshang; Yan, Deyue

    2013-08-10

    A multifunctional pH-sensitive superparamagnetic iron-oxide (SPIO) nanocomposite system was developed for simultaneous tumor magnetic resonance imaging (MRI) and therapy. Small-size SPIO nanoparticles were chemically bonded with antitumor drug doxorubicin (DOX) and biocompatible poly(ethylene glycol) (PEG) through pH-sensitive acylhydrazone linkages, resulting in the formation of SPIO nanocomposites with magnetic targeting and pH-sensitive properties. These DOX-conjugated SPIO nanocomposites exhibited not only good stability in aqueous solution but also high saturation magnetizations. Under an acidic environment, the DOX was quickly released from the SPIO nanocomposites due to the cleavage of pH-sensitive acylhydrazone linkages. With the help of magnetic field, the DOX-conjugated SPIO nanocomposites showed high cellular uptake, indicating their magnetic targeting property. Comparing to free DOX, the DOX-conjugated SPIO nanocomposites showed better antitumor effect under magnetic field. At the same time, the relaxivity value of these SPIO nanocomposites was higher than 146s(-1)mM(-1) Fe, leading to ~4 times enhancement compared to that of free SPIO nanoparticles. As a negative contrast agent, these SPIO nanocomposites illustrated high resolution in MRI diagnosis of tumor-bearing mice. All of these results confirm that these pH-sensitive SPIO nanocomposites are promising hybrid materials for synergistic MRI diagnosis and tumor therapy. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Simulation study of a high performance brain PET system with dodecahedral geometry.

    PubMed

    Tao, Weijie; Chen, Gaoyu; Weng, Fenghua; Zan, Yunlong; Zhao, Zhixiang; Peng, Qiyu; Xu, Jianfeng; Huang, Qiu

    2018-05-25

    In brain imaging, the spherical PET system achieves the highest sensitivity when the solid angle is concerned. However it is not practical. In this work we designed an alternative sphere-like scanner, the dodecahedral scanner, which has a high sensitivity in imaging and a high feasibility to manufacture. We simulated this system and compared the performance with a few other dedicated brain PET systems. Monte Carlo simulations were conducted to generate data of the dedicated brain PET system with the dodecahedral geometry (11 regular pentagon detectors). The data were then reconstructed using the in-house developed software with the fully three-dimensional maximum-likelihood expectation maximization (3D-MLEM) algorithm. Results show that the proposed system has a high sensitivity distribution for the whole field of view (FOV). With a depth-of-interaction (DOI) resolution around 6.67 mm, the proposed system achieves the spatial resolution of 1.98 mm. Our simulation study also shows that the proposed system improves the image contrast and reduces noise compared with a few other dedicated brain PET systems. Finally, simulations with the Hoffman phantom show the potential application of the proposed system in clinical applications. In conclusion, the proposed dodecahedral PET system is potential for widespread applications in high-sensitivity, high-resolution PET imaging, to lower the injected dose. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Heightened Sensitivity to Reward and Punishment in Anorexia Nervosa

    PubMed Central

    Jappe, Leah M.; Frank, Guido K.W.; Shott, Megan E.; Rollin, Michael D.H.; Pryor, Tamara; Hagman, Jennifer O.; Yang, Tony T.; Davis, Elizabeth

    2011-01-01

    Objective To test whether women with Anorexia Nervosa (AN) have increased sensitivity to punishing or rewarding stimuli, behaviors that could drive high self-control and anxious, avoidant behaviors. Method Sixty-four women completed the study: 33 control women (CW, mean age 19.7 years) and 31 AN (mean age 19.6 years). Participants completed diagnostic exams, questionnaires for eating disorder severity and personality, as well as the Sensitivity to Punishment/Sensitivity to Reward Questionnaire (SPSRQ). Results AN scored higher than CW on SPSRQ sensitivity to punishment (p<0.00001) and sensitivity to reward (p=0.005). AN women without anxiety or depression continued to have increased SPSRQ scores compared to CW. Conclusion This is the first study comparing the SPSRQ in AN and CW. Results suggest that reward and punishment sensitivity are increased in AN and could be potential trait markers. It is possible that harm-avoidant, anxious behaviors in AN are related to this heightened sensitivity. PMID:21472750

  12. Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.

    PubMed

    Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk

    2013-06-01

    The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. The effects of physiological arousal on cognitive and psychomotor performance among individuals with high and low anxiety sensitivity.

    PubMed

    Barnard, Kirsten E; Broman-Fulks, Joshua J; Michael, Kurt D; Webb, Rosemary M; Zawilinski, Laci L

    2011-03-01

    Information-processing models of anxiety posit that anxiety pathology is associated with processing biases that consume cognitive resources and may detract from one's ability to process environmental stimuli. Previous research has consistently indicated that high anxiety has a negative impact on cognitive and psychomotor performance. Anxiety sensitivity, or the fear of anxiety and anxiety-related arousal sensations, is an anxiety vulnerability factor that has been shown to play a role in the development and maintenance of panic attacks and panic disorder. However, relatively little is known regarding the potential impact of anxiety sensitivity on performance. In the present study, 105 college students who scored either high (≥ 24) or low (≤ 14) on the Anxiety Sensitivity Index were randomly assigned to complete a series of arousal-induction tasks or no activity, followed immediately by three cognitive and psychomotor performance tasks: digit span - backward, math fluency, and grooved pegboard. Results indicated that participants with high anxiety sensitivity performed comparably to individuals with low anxiety sensitivity on each task, regardless of arousal level.

  14. An automated quantitative DNA image cytometry system detects abnormal cells in cervical cytology with high sensitivity.

    PubMed

    Wong, O G; Ho, M W; Tsun, O K; Ng, A K; Tsui, E Y; Chow, J N; Ip, P P; Cheung, A N

    2018-03-26

    To evaluate the performance of an automated DNA-image-cytometry system as a tool to detect cervical carcinoma. Of 384 liquid-based cervical cytology samples with available biopsy follow-up were analyzed by both the Imager System and a high-risk HPV test (Cobas). The sensitivity and specificity of Imager System for detecting biopsy proven high-grade squamous intraepithelial lesion (HSIL, cervical intraepithelial neoplasia [CIN]2-3) and carcinoma were 89.58% and 56.25%, respectively, compared to 97.22% and 23.33% of HPV test but additional HPV 16/18 genotyping increased the specificity to 69.58%. The sensitivity and specificity of the Imager System for predicting HSIL+ (CIN2-3+) lesions among atypical squamous cells of undetermined significance samples were 80.00% and 70.53%, respectively, compared to 100% and 11.58% of HPV test whilst the HPV 16/18 genotyping increased the specificity to 77.89%. Among atypical squamous cells-cannot exclude HSIL, the sensitivity and specificity of Imager System for predicting HSIL+ (CIN2-3+) lesions upon follow up were 82.86% and 33.33%%, respectively, compared to 97.14% and 4.76% of HPV test and the HPV 16/18 genotyping increased the specificity to 19.05%. Among low-grade squamous intraepithelial lesion cases, the sensitivity and specificity of the Imager System for predicting HSIL+ (CIN2-3+) lesions were 66.67% and 35.71%%, respectively, compared to 66.67% and 29.76% of HPV test while HPV 16/18 genotyping increased the specificity to 79.76%. The overall results of imager and high-risk HPV test agreed in 69.43% (268) of all samples. The automated imager system and HPV 16/18 genotyping can enhance the specificity of detecting HSIL+ (CIN2-3+) lesions. © 2018 John Wiley & Sons Ltd.

  15. Development of new resist materials for 193-nm dry and immersion lithography

    NASA Astrophysics Data System (ADS)

    Sasaki, Takashi; Shirota, Naoko; Takebe, Yoko; Yokokoji, Osamu

    2006-03-01

    We earlier developed new monocyclic fluoropolymers (FUGU) for F II resist materials. But, it is necessary for FUGU to improve of their characteristics, especially the dry-etching resistance, in order to apply for ArF lithography at fine design rules. We have tried to combine FUGUs with Adamntyl methacrylates based conventional ArF resist polymer. In this paper, we have investigated the role of cyclic fluorinated unit, FUGU, in 193 nm resist polymers by analyzing the dissolution behavior. We found that FGEAM showed high sensitivity and good dissolution contrast, compared with acrylate based conventional samples at low PEB temperature (100 °C). And this difference of sensitivity was clearly found when weak acidity PAGs were used. From the dissolution behaviors of FGEAM, FUGU unit can work to improve the resist sensitivity in acrylate based ArF resist polymers. And we also found that FGEAM showed long acid diffusion length on PEB process, compared with Conventional samples. These result show that FUGU unit has a unique characteristics of the sensitivity with 193nm exposure and the acid diffusion behavior. We also investigated a new series of fluorinated copolymers for 193-nm lithography, combination of FUGU monomer and acrylate units which are used in conventional ArF resist. Six ter-polymers of FUGU, combination of FUGU monomers and EAdMA, GBLMA and HAdMA were prepared. We found that FUGU ter-polymers had a good dry etching resistance keeping high transparency at 193nm. And FUGU ter-polymers showed high sensitivity toward 193nm exposure. FUGU ter-polymers also had a high hydrophobic properties compared conventional type ArF resist polymers. So we also expect FUGU ter-polymers to be useful for ArF dry and immersion lithography.

  16. Engineered nanoconstructs for the multiplexed and sensitive detection of high-risk pathogens

    NASA Astrophysics Data System (ADS)

    Seo, Youngmin; Kim, Ji-Eun; Jeong, Yoon; Lee, Kwan Hong; Hwang, Jangsun; Hong, Jongwook; Park, Hansoo; Choi, Jonghoon

    2016-01-01

    Many countries categorize the causative agents of severe infectious diseases as high-risk pathogens. Given their extreme infectivity and potential to be used as biological weapons, a rapid and sensitive method for detection of high-risk pathogens (e.g., Bacillus anthracis, Francisella tularensis, Yersinia pestis, and Vaccinia virus) is highly desirable. Here, we report the construction of a novel detection platform comprising two units: (1) magnetic beads separately conjugated with multiple capturing antibodies against four different high-risk pathogens for simple and rapid isolation, and (2) genetically engineered apoferritin nanoparticles conjugated with multiple quantum dots and detection antibodies against four different high-risk pathogens for signal amplification. For each high-risk pathogen, we demonstrated at least 10-fold increase in sensitivity compared to traditional lateral flow devices that utilize enzyme-based detection methods. Multiplexed detection of high-risk pathogens in a sample was also successful by using the nanoconstructs harboring the dye molecules with fluorescence at different wavelengths. We ultimately envision the use of this novel nanoprobe detection platform in future applications that require highly sensitive on-site detection of high-risk pathogens.

  17. Biomimetic self-templating optical structures fabricated by genetically engineered M13 bacteriophage.

    PubMed

    Kim, Won-Geun; Song, Hyerin; Kim, Chuntae; Moon, Jong-Sik; Kim, Kyujung; Lee, Seung-Wuk; Oh, Jin-Woo

    2016-11-15

    Here, we describe a highly sensitive and selective surface plasmon resonance sensor system by utilizing self-assembly of genetically engineered M13 bacteriophage. About 2700 copies of genetically expressed peptide copies give superior selectivity and sensitivity to M13 phage-based SPR sensor. Furthermore, the sensitivity of the M13 phage-based SPR sensor was enhanced due to the aligning of receptor matrix in specific direction. Incorporation of specific binding peptide (His Pro Gln: HPQ) gives M13 bacteriophage high selectivity for the streptavidin. Our M13 phage-based SPR sensor takes advantage of simplicity of self-assembly compared with relatively complex photolithography techniques or chemical conjugations. Additionally, designed structure which is composed of functionalized M13 bacteriophage can simultaneously improve the sensitivity and selectivity of SPR sensor evidently. By taking advantages of the genetic engineering and self-assembly, we propose the simple method for fabricating novel M13 phage-based SPR sensor system which has a high sensitivity and high selectivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Modulation of meso-limbic reward processing by motivational tendencies in young adolescents and adults

    PubMed Central

    Joseph, Jane E.; Zhu, Xun; Lynam, Donald; Kelly, Thomas H.

    2015-01-01

    Adolescence is a particularly vulnerable period for the onset of substance use disorders and other psychopathology. Individual variability in motivational tendencies and temperament and significant changes in functional brain organization during adolescence are important factors to consider in the development of substance use and dependence. Recent conceptualizations suggest that sensitivity to reward is heightened in adolescence and that this motivation tendency may precipitate subsequent substance abuse. The present study examined the role of personality traits in mesolimbic neurobehavioral response on a monetary incentive delay (MID) task in young adolescents (11–14 years) and emerging adults (18–25 years) using functional magnetic resonance imaging. As a group, adolescents were not more sensitive to gains than losses compared to adults during either anticipatory and feedback phases; instead, compared to adults they showed less sensitivity to incentive magnitude in mesolimbic circuitry during anticipation and feedback stages. However, personality modulated this response such that adolescents high in impulsivity or low in avoidance tendencies showed greater gain sensitivity and adolescents high in avoidance showed greater loss sensitivity during cue anticipation. In adults, mesolimbic response was modulated by the impulsivity construct such that high-impulsive adults showed reduced magnitude sensitivity during both anticipation and feedback compared to low impulsive adults. The present findings suggest that impulsive personality significantly modulates mesolimbic reward response during both adolescence and adulthood but avoidance and approach tendencies also modulate this response in adolescents. Moreover, personality modulated incentive valence in adolescents but incentive magnitude in adults. Collectively, these findings suggest that mesolimbic reward circuitry function is modulated by somewhat different parameters in adolescence than in adulthood. PMID:26690806

  19. Self-Assembled ZnO Nanosheet-Based Spherical Structure as Photoanode in Dye-Sensitized Solar Cells

    NASA Astrophysics Data System (ADS)

    Ameri, Mohsen; Raoufi, Meysam; Zamani-Meymian, M.-R.; Samavat, Feridoun; Fathollahi, M.-R.; Mohajerani, Ezeddin

    2018-03-01

    High surface area and enhanced light scattering of ZnO nanosheet aggregates have made them a promising active layer candidate material for fabrication of nanostructure dye-sensitized solar cells. Here, we propose a facile preparation method of such ZnO nanosheet structures, and in order to verify their applicability as photoanode material for dye-sensitized solar cells, we employ morphological, optical, structural and electrical measurements. The results reveal the high surface area available for dye molecules for enhancing adsorption, high light scattering and competitive power conversion efficiencies compared to the works in literature. Finally, the device is optimized with respect to the photoanode thickness. The favorable features shown here can extend the application of the structure to other types of sensitization-based perovskite and quantum dot solar cells.

  20. Parenting and adolescents' psychological adjustment: Longitudinal moderation by adolescents' genetic sensitivity.

    PubMed

    Stocker, Clare M; Masarik, April S; Widaman, Keith F; Reeb, Ben T; Boardman, Jason D; Smolen, Andrew; Neppl, Tricia K; Conger, Katherine J

    2017-10-01

    We examined whether adolescents' genetic sensitivity, measured by a polygenic index score, moderated the longitudinal associations between parenting and adolescents' psychological adjustment. The sample included 323 mothers, fathers, and adolescents (177 female, 146 male; Time 1 [T1] average age = 12.61 years, SD = 0.54 years; Time 2 [T2] average age = 13.59 years, SD = 0.59 years). Parents' warmth and hostility were rated by trained, independent observers using videotapes of family discussions. Adolescents reported their symptoms of anxiety, depressed mood, and hostility at T1 and T2. The results from autoregressive linear regression models showed that adolescents' genetic sensitivity moderated associations between observations of both mothers' and fathers' T1 parenting and adolescents' T2 composite maladjustment, depression, anxiety, and hostility. Compared to adolescents with low genetic sensitivity, adolescents with high genetic sensitivity had worse adjustment outcomes when parenting was low on warmth and high on hostility. When parenting was characterized by high warmth and low hostility, adolescents with high genetic sensitivity had better adjustment outcomes than their counterparts with low genetic sensitivity. The results support the differential susceptibility model and highlight the complex ways that genes and environment interact to influence development.

  1. Effects of periodontal therapy on C-reactive protein and HDL in serum of subjects with periodontitis.

    PubMed

    Leite, Anne Carolina Eleutério; Carneiro, Valéria Martins de Araújo; Guimarães, Maria do Carmo Machado

    2014-01-01

    To investigate the effects of nonsurgical periodontal therapy on levels of high-sensitivity C-reactive protein in the sera and its association with body mass index and high density lipoprotein in subjects with severe periodontitis. Sera from 28 subjects (mean age: 34.36±6.24; 32% men) with severe periodontitis and 27 healthy controls (mean age: 33.18±6.42; 33% men) were collected prior to periodontal therapy. Blood samples were obtained from 23 subjects who completed therapy (9-12 months). Oral and systemic parameters such as the number of blood cells, glucose examination, lipid profile, and high-sensitivity C-reactive protein levels accessed by high-sensitivity immunonephelometry assay, were included. Before therapy, in the periodontitis group, the ratio of subjects with high-sensitivity C-reactive protein <0.3 mg/dL was statistically lower than in the control group (P<0.0216). After therapy, the ratio of subjects with high-sensitivity C-reactive protein <0.3 mg/dL was significantly higher (65.22%) (P<0.0339). The mean value for body mass index was statistically lower in subjects with high-sensitivity C-reactive protein <0.3 mg/dL (24.63±4.19), compared with those with high-sensitivity C-reactive protein >0.3 mg/dL (28.91±6.03) (P<0.0411). High density lipoprotein presented a mean value statistically higher after therapy (P<0.0027). In systemically healthy subjects with periodontitis, periodontal therapy was associated with decreased levels of circulating high-sensitivity C-reactive protein and increase of high density lipoprotein in serum. The clinical trial was registered at http://www.clinicaltrials.gov.br/, No. RBR-24T799.

  2. Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression

    NASA Astrophysics Data System (ADS)

    Wong, Chak P.; Gump, Jared C.

    2006-07-01

    Explosive formulations with reduced-sensitivity RDX showed reduced shock sensitivity using Naval Ordnance Laboratory (NOL) Large Scale Gap Test, compared with similar formulations using standard RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light on the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. I-RDX®, a form of reduced- sensitivity RDX was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transform IR (FTIR). The pressure dependence of the Raman mode frequencies of I-RDX® was determined and compared with that of standard RDX. The behavior of I-RDX® near the pressure at which standard RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph is presented.

  3. Sensitivity, specificity, and predictive values of pediatric metabolic syndrome components in relation to adult metabolic syndrome: the Princeton LRC follow-up study.

    PubMed

    Huang, Terry T-K; Nansel, Tonja R; Belsheim, Allen R; Morrison, John A

    2008-02-01

    To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoff points in relation to adult MetS. Data from the National Heart, Lung, and Blood Institute Lipid Research Clinics Princeton Prevalence Study (1973-1976) and the Princeton Follow-up Study (2000-2004) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff point and for aggregates of components. Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all 5 pediatric MetS components were considered, the presence of at least 1 abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Considering multiple metabolic variables in childhood can improve the predictive usefulness for adult MetS, compared with each component or body mass alone. MetS variables may be useful for identifying some children who are at risk for prevention interventions.

  4. A Monte Carlo study of different detector geometries for HAWC

    NASA Astrophysics Data System (ADS)

    Gebauer, Iris

    Compared to other parts of astronomy the study of the universe at energies above 100GeV is a relatively new field. Pointed instruments presently achieve the highest sensitivities. They have detected gamma-rays from at least 10 sources, but they are only able to monitor a relatively small fraction of the sky. The detection of exciting phenomena such as Gamma-ray Bursts (GRBs) requires a highly sensitive detector capable of continuously monitoring the entire overhead sky. Such an instrument could make an unbiased study of the entire field of view. With sufficient sensitivity it could detect short transients (~ 15 minutes) and study the time structure of Active galactic nuclei (AGN) flares at energies unattainable to space-based instruments. This thesis describes the design and performance of the next generation water Cherenkov detector HAWC (High Altitude Water Cherenkov). Focussing on the performance in background-rejection and sensitivity to point sources, two possible detector geometries, different in the way the photomultipliers (PMTs) are separated from each other, are compared.

  5. An ultra-sensitive wearable accelerometer for continuous heart and lung sound monitoring.

    PubMed

    Hu, Yating; Xu, Yong

    2012-01-01

    This paper presents a chest-worn accelerometer with high sensitivity for continuous cardio-respiratory sound monitoring. The accelerometer is based on an asymmetrical gapped cantilever which is composed of a bottom mechanical layer and a top piezoelectric layer separated by a gap. This novel structure helps to increase the sensitivity by orders of magnitude compared with conventional cantilever based accelerometers. The prototype with a resonant frequency of 1100Hz and a total weight of 5 gram is designed, constructed and characterized. The size of the prototype sensor is 35mm×18mm×7.8mm (l×w×t). A built-in charge amplifier is used to amplify the output voltage of the sensor. A sensitivity of 86V/g and a noise floor of 40ng/√Hz are obtained. Preliminary tests for recording both cardiac and respiratory signals are carried out on human body and the new sensor exhibits better performance compared with a high-end electronic stethoscope.

  6. A New Pulse Pileup Rejection Method Based on Position Shift Identification

    NASA Astrophysics Data System (ADS)

    Gu, Z.; Prout, D. L.; Taschereau, R.; Bai, B.; Chatziioannou, A. F.

    2016-02-01

    Pulse pileup events degrade the signal-to-noise ratio (SNR) of nuclear medicine data. When such events occur in multiplexed detectors, they cause spatial misposition, energy spectrum distortion and degraded timing resolution, which leads to image artifacts. Pulse pileup is pronounced in PETbox4, a bench top PET scanner dedicated to high sensitivity and high resolution imaging of mice. In that system, the combination of high absolute sensitivity, long scintillator decay time (BGO) and highly multiplexed electronics lead to a significant fraction of pulse pileup, reached at lower total activity than for comparable instruments. In this manuscript, a new pulse pileup rejection method named position shift rejection (PSR) is introduced. The performance of PSR is compared with a conventional leading edge rejection (LER) method and with no pileup rejection implemented (NoPR). A comprehensive digital pulse library was developed for objective evaluation and optimization of the PSR and LER, in which pulse waveforms were directly recorded from real measurements exactly representing the signals to be processed. Physical measurements including singles event acquisition, peak system sensitivity and NEMA NU-4 image quality phantom were also performed in the PETbox4 system to validate and compare the different pulse pile-up rejection methods. The evaluation of both physical measurements and model pulse trains demonstrated that the new PSR performs more accurate pileup event identification and avoids erroneous rejection of valid events. For the PETbox4 system, this improvement leads to a significant recovery of sensitivity at low count rates, amounting to about 1/4th of the expected true coincidence events, compared to the LER method. Furthermore, with the implementation of PSR, optimal image quality can be achieved near the peak noise equivalent count rate (NECR).

  7. High-Speed Real-Time Resting-State fMRI Using Multi-Slab Echo-Volumar Imaging

    PubMed Central

    Posse, Stefan; Ackley, Elena; Mutihac, Radu; Zhang, Tongsheng; Hummatov, Ruslan; Akhtari, Massoud; Chohan, Muhammad; Fisch, Bruce; Yonas, Howard

    2013-01-01

    We recently demonstrated that ultra-high-speed real-time fMRI using multi-slab echo-volumar imaging (MEVI) significantly increases sensitivity for mapping task-related activation and resting-state networks (RSNs) compared to echo-planar imaging (Posse et al., 2012). In the present study we characterize the sensitivity of MEVI for mapping RSN connectivity dynamics, comparing independent component analysis (ICA) and a novel seed-based connectivity analysis (SBCA) that combines sliding-window correlation analysis with meta-statistics. This SBCA approach is shown to minimize the effects of confounds, such as movement, and CSF and white matter signal changes, and enables real-time monitoring of RSN dynamics at time scales of tens of seconds. We demonstrate highly sensitive mapping of eloquent cortex in the vicinity of brain tumors and arterio-venous malformations, and detection of abnormal resting-state connectivity in epilepsy. In patients with motor impairment, resting-state fMRI provided focal localization of sensorimotor cortex compared with more diffuse activation in task-based fMRI. The fast acquisition speed of MEVI enabled segregation of cardiac-related signal pulsation using ICA, which revealed distinct regional differences in pulsation amplitude and waveform, elevated signal pulsation in patients with arterio-venous malformations and a trend toward reduced pulsatility in gray matter of patients compared with healthy controls. Mapping cardiac pulsation in cortical gray matter may carry important functional information that distinguishes healthy from diseased tissue vasculature. This novel fMRI methodology is particularly promising for mapping eloquent cortex in patients with neurological disease, having variable degree of cooperation in task-based fMRI. In conclusion, ultra-high-real-time speed fMRI enhances the sensitivity of mapping the dynamics of resting-state connectivity and cerebro-vascular pulsatility for clinical and neuroscience research applications. PMID:23986677

  8. High Temperature and High Sensitive NOx Gas Sensor with Hetero-Junction Structure using Laser Ablation Method

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Shi, Liqin; Hasegawa, Yuki; Katsube, Teruaki

    In order to develop a high temperature (200°C˜400°C) and high sensitive NOx gas sensor, we developed a new structure of SiC-based hetero-junction device Pt/SnO2/SiC/Ni, Pt/In2O3/SiC/Ni and Pt/WO3/SiC/Ni using a laser ablation method for the preparation of both metal (Pt) electrode and metal-oxide film. It was found that Pt/In2O3/SiC/Ni sensor shows higher sensitivity to NO2 gas compared with the Pt/SnO2/SiC/Ni and Pt/WO3/SiC/Ni sensor, whereas the Pt/WO3/SiC/Ni sensor had better sensitivity to NO gas. These results suggest that selective detection of NO and NO2 gases may be obtained by choosing different metal oxide films.

  9. High-sensitivity ESCA instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davies, R.D.; Herglotz, H.K.; Lee, J.D.

    1973-01-01

    A new electron spectroscopy for chemical analysis (ESCA) instrument has been developed to provide high sensitivity and efficient operation for laboratory analysis of composition and chemical bonding in very thin surface layers of solid samples. High sensitivity is achieved by means of the high-intensity, efficient x-ray source described by Davies and Herglotz at the 1968 Denver X-Ray Conference, in combination with the new electron energy analyzer described by Lee at the 1972 Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy. A sample chamber designed to provide for rapid introduction and replacement of samples has adequate facilities for various sample treatmentsmore » and conditiouing followed immediately by ESCA analysis of the sample. Examples of application are presented, demonstrating the sensitivity and resolution achievable with this instrument. Its usefulness in trace surface analysis is shown and some chemical shifts'' measured by the instrument are compared with those obtained by x-ray spectroscopy. (auth)« less

  10. Validity of the Hum Test, a Simple and Reliable Alternative to the Weber Test.

    PubMed

    Ahmed, Omar H; Gallant, Sara C; Ruiz, Ryan; Wang, Binhuan; Shapiro, William H; Voigt, Erich P

    2018-06-01

    To compare the diagnostic performance of the Hum Test against the Weber Test using pure tone audiometry (PTA) as the "gold standard" comparator. 29 participants with normal hearing of ages 18 to 35 without any history of hearing abnormalities or otologic conditions were enrolled. Subjects underwent three tests (Hum Test, Weber Test, and PTA) across two conditions: with an ear plug in one ear (side randomized) and without ear plugs. When examining the ability of the Hum Test to detect simulated conductive hearing loss (CHL), the test had a sensitivity of 89.7% and specificity of 100% with high pitched humming and 93.1% and 100%, respectively, with low pitched humming. The Weber Test had a sensitivity and specificity of 96.6% and 100%, respectively. McNemar's test demonstrated agreement between the Hum Test, performed with either high pitched ( P = .32) or low pitched ( P = .56) humming, and the Weber Test. Receiver operating characteristic (ROC) curves for the Hum Test (both high and low pitched) and Weber test were compared and demonstrated no statistically significant difference. The Hum Test is comparable to the Weber Test with regards to its sensitivity, specificity, and diagnostic accuracy in assessing new onset unilateral CHL in previously normal hearing subjects.

  11. High Sensitivity Refractometer Based on TiO₂-Coated Adiabatic Tapered Optical Fiber via ALD Technology.

    PubMed

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-08-15

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO₂) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO₂ nanofilm compared to that of silica, an asymmetric Fabry-Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO₂ nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO₂ on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373-1.3500. Due to TiO₂'s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field.

  12. An approach to measure parameter sensitivity in watershed ...

    EPA Pesticide Factsheets

    Hydrologic responses vary spatially and temporally according to watershed characteristics. In this study, the hydrologic models that we developed earlier for the Little Miami River (LMR) and Las Vegas Wash (LVW) watersheds were used for detail sensitivity analyses. To compare the relative sensitivities of the hydrologic parameters of these two models, we used Normalized Root Mean Square Error (NRMSE). By combining the NRMSE index with the flow duration curve analysis, we derived an approach to measure parameter sensitivities under different flow regimes. Results show that the parameters related to groundwater are highly sensitive in the LMR watershed, whereas the LVW watershed is primarily sensitive to near surface and impervious parameters. The high and medium flows are more impacted by most of the parameters. Low flow regime was highly sensitive to groundwater related parameters. Moreover, our approach is found to be useful in facilitating model development and calibration. This journal article describes hydrological modeling of climate change and land use changes on stream hydrology, and elucidates the importance of hydrological model construction in generating valid modeling results.

  13. High temperature sensitivity is intrinsic to voltage-gated potassium channels

    PubMed Central

    Yang, Fan; Zheng, Jie

    2014-01-01

    Temperature-sensitive transient receptor potential (TRP) ion channels are members of the large tetrameric cation channels superfamily but are considered to be uniquely sensitive to heat, which has been presumed to be due to the existence of an unidentified temperature-sensing domain. Here we report that the homologous voltage-gated potassium (Kv) channels also exhibit high temperature sensitivity comparable to that of TRPV1, which is detectable under specific conditions when the voltage sensor is functionally decoupled from the activation gate through either intrinsic mechanisms or mutations. Interestingly, mutations could tune Shaker channel to be either heat-activated or heat-deactivated. Therefore, high temperature sensitivity is intrinsic to both TRP and Kv channels. Our findings suggest important physiological roles of heat-induced variation in Kv channel activities. Mechanistically our findings indicate that temperature-sensing TRP channels may not contain a specialized heat-sensor domain; instead, non-obligatory allosteric gating permits the intrinsic heat sensitivity to drive channel activation, allowing temperature-sensitive TRP channels to function as polymodal nociceptors. DOI: http://dx.doi.org/10.7554/eLife.03255.001 PMID:25030910

  14. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    PubMed

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  15. Dyes designed for high sensitivity detection of double-stranded DNA

    DOEpatents

    Glazer, Alexander N.; Benson, Scott C.

    2000-01-01

    Novel fluorescent dyes are provided, characterized by having a fluorophore joined to a cationic chain. The dyes are found to provide for high enhancement upon binding to nucleic acid and have strong binding affinities to the nucleic acid, as compared to the fluorophore without the polycationic chain. The dyes find use in detection of dsDNA in gel electrophoresis and solution at substantially higher sensitivities using substantially less dye.

  16. Dyes designed for high sensitivity detection of double-stranded DNA

    DOEpatents

    Glazer, Alexander N.; Benson, Scott C.

    1998-01-01

    Novel fluorescent dyes are provided, characterized by having a fluorophore joined to a cationic chain. The dyes are found to provide for high enhancement upon binding to nucleic acid and have strong binding affinities to the nucleic acid, as compared to the fluorophore without the polycationic chain. The dyes find use in detection of dsDNA in gel electrophoresis and solution at substantially higher sensitivities using substantially less dye.

  17. Do We Know Who Will Drop out?: A Review of the Predictors of Dropping out of High School--Precision, Sensitivity, and Specificity

    ERIC Educational Resources Information Center

    Bowers, Alex J.; Sprott, Ryan; Taff, Sherry A.

    2013-01-01

    The purpose of this study is to review the literature on the most accurate indicators of students at risk of dropping out of high school. We used Relative Operating Characteristic (ROC) analysis to compare the sensitivity and specificity of 110 dropout flags across 36 studies. Our results indicate that 1) ROC analysis provides a means to compare…

  18. Sensitivity of photoacoustic microscopy

    PubMed Central

    Yao, Junjie; Wang, Lihong V.

    2014-01-01

    Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given percentage change in the optical absorption coefficient yields the same percentage change in the photoacoustic amplitude), and its ultimate detection sensitivity is limited only by thermal noise. Focusing on the engineering aspects of PAM, this Review discusses the detection sensitivity of PAM, compares the detection efficiency of different PAM designs, and summarizes the imaging performance of various endogenous and exogenous contrast agents. It then describes representative PAM applications with high detection sensitivity, and outlines paths to further improvement. PMID:25302158

  19. A novel photonic crystal fiber Mach-Zehnder interferometer for enhancing refractive index measurement sensitivity

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Xia, Feng; Hu, Hai-feng; Chen, Mao-qing

    2017-11-01

    A novel refractive index (RI) sensor based on photonic crystal fiber Mach-Zehnder interferometer (PCF-MZI) was proposed. It was realized by cascading a section of PCF with half-taper collapse regions (HTCRs) between two single mode fibers (SMFs). The relationship between RI sensitivity and interference length of the PCF-MZI was firstly investigated. Both simulation and experimental results showed that RI sensitivity increased with the increase of interference length. Afterwards, influence of HTCR parameters on RI sensitivity was experimentally investigated to further improve the sensitivity. With intensification of arc discharge intensity in HTCR fabrication process, HTCR with larger maximum taper diameter and longer collapsed region length was obtained, which enhanced evanescent field of the PCF-MZI and then generated higher RI sensitivity. Consequently, a high RI sensitivity of 181.96 nm/refractive index unit (RIU) was achieved in the RI range of 1.3333-1.3574. Increasing arc discharge intensity in HTCR fabrication process has the capacity to improve RI sensitivity of PCF-MZI and meanwhile provides higher mechanical strength and longer sensor life compared to the traditional method of tapering the fiber, which improves the RI sensitivity at the cost of reducing mechanical strength of the sensor. This PCF-MZI was characterized by high RI sensitivity, ease of fabrication, high mechanical strength, and robustness.

  20. Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression

    NASA Astrophysics Data System (ADS)

    Wong, Chak

    2005-07-01

    Explosives formulations with Reduced- Sensitivity RDX showed reduced shock sensitivity using NOL Large Scale Gap Test, compared with similar formulations using normal RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light to the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. SIRDX, a form of Reduced- Sensitivity RDX, was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transformed IR (FTIR). The pressure dependence of the Raman mode frequencies of SIRDX was determined and compared with that of normal RDX. The behavior of SIRDX near the pressure at which normal RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph will be presented. Implications to the reduction in sensitivity will be discussed.

  1. Slightly elevated high-sensitivity C-reactive protein (hsCRP) concentrations are associated with carotid atherosclerosis in women with varying degrees of glucose tolerance.

    PubMed

    Prahl, Ulrica; Wikstrand, John; Bergström, Göran M L; Behre, Carl Johan; Hulthe, Johannes; Fagerberg, Björn

    2010-11-01

    We examined whether high-sensitivity C-reactive protein (hsCRP) ≥2.0 mg/L was associated with increased intima-media thickness (IMT), plaque burden, and plaque echolucency in carotid arteries. Women (n = 635) from a population sample of 64-year-old females with varying degrees of glucose tolerance underwent risk factor assessment, measurement of hsCRP, and ultrasound examinations of the carotid arteries. Participants with hsCRP levels ≥2.0 mg/L had elevated carotid bulb IMT independently of other cardiovascular risk factors compared with those with hsCRP <2.0 mg/L. The participants with plaques in the highhsCRP group had larger total plaque area compared to those with plaque in the lower hsCRP group. Plaque echolucency did not differ between groups. High-sensitivity CRP levels ≥2.0 mg/L were accompanied by elevated IMT in the carotid bulbs independently of other cardiovascular risk factors. Total plaque area was larger among women with plaques in the high hsCRP group versus the lower hsCRP group.

  2. Validated method for quantification of genetically modified organisms in samples of maize flour.

    PubMed

    Kunert, Renate; Gach, Johannes S; Vorauer-Uhl, Karola; Engel, Edwin; Katinger, Hermann

    2006-02-08

    Sensitive and accurate testing for trace amounts of biotechnology-derived DNA from plant material is the prerequisite for detection of 1% or 0.5% genetically modified ingredients in food products or raw materials thereof. Compared to ELISA detection of expressed proteins, real-time PCR (RT-PCR) amplification has easier sample preparation and detection limits are lower. Of the different methods of DNA preparation CTAB method with high flexibility in starting material and generation of sufficient DNA with relevant quality was chosen. Previous RT-PCR data generated with the SYBR green detection method showed that the method is highly sensitive to sample matrices and genomic DNA content influencing the interpretation of results. Therefore, this paper describes a real-time DNA quantification based on the TaqMan probe method, indicating high accuracy and sensitivity with detection limits of lower than 18 copies per sample applicable and comparable to highly purified plasmid standards as well as complex matrices of genomic DNA samples. The results were evaluated with ValiData for homology of variance, linearity, accuracy of the standard curve, and standard deviation.

  3. A Comparative Study of Very High Burning Rate Materials - HIVELITE compositions 300511 and 300435

    DTIC Science & Technology

    1982-08-01

    explosives and more or as sensitive as RDX and HMX . Thermal Sensitivity Differential Thermal Analysis/Thermogravimetric Analysis (DTA/TGA) Simultaneous...impact than Comp B end RDX but is less sensitive than lead azide. HIVELITE 30051i on the other hand, is less sensitive than Comp B and RDX on the ERL...represents the alpha to beta phase transition of KNO 3 . This endotherm is followed by four exotherms with peaks at 538 K (265*C), 567 K (2940C), 598 K

  4. Multivariate classification with random forests for gravitational wave searches of black hole binary coalescence

    NASA Astrophysics Data System (ADS)

    Baker, Paul T.; Caudill, Sarah; Hodge, Kari A.; Talukder, Dipongkar; Capano, Collin; Cornish, Neil J.

    2015-03-01

    Searches for gravitational waves produced by coalescing black hole binaries with total masses ≳25 M⊙ use matched filtering with templates of short duration. Non-Gaussian noise bursts in gravitational wave detector data can mimic short signals and limit the sensitivity of these searches. Previous searches have relied on empirically designed statistics incorporating signal-to-noise ratio and signal-based vetoes to separate gravitational wave candidates from noise candidates. We report on sensitivity improvements achieved using a multivariate candidate ranking statistic derived from a supervised machine learning algorithm. We apply the random forest of bagged decision trees technique to two separate searches in the high mass (≳25 M⊙ ) parameter space. For a search which is sensitive to gravitational waves from the inspiral, merger, and ringdown of binary black holes with total mass between 25 M⊙ and 100 M⊙ , we find sensitive volume improvements as high as 70±13%-109±11% when compared to the previously used ranking statistic. For a ringdown-only search which is sensitive to gravitational waves from the resultant perturbed intermediate mass black hole with mass roughly between 10 M⊙ and 600 M⊙ , we find sensitive volume improvements as high as 61±4%-241±12% when compared to the previously used ranking statistic. We also report how sensitivity improvements can differ depending on mass regime, mass ratio, and available data quality information. Finally, we describe the techniques used to tune and train the random forest classifier that can be generalized to its use in other searches for gravitational waves.

  5. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    PubMed

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. [Functional endoscopic evaluation of swallowing in infants with deglutition disorders].

    PubMed

    Partida-Justo, I; Israel Grijalva-Otero, J E; Ramírez-Figueroa, J L; Sepúlveda-Vildosola, A C; Zurita-Cruz, J N

    2017-10-25

    Functional endoscopic evaluation of swallowing (FEES) is a recognized method for Deglutition Disorders (DD) in adults, with anecdotal experience in children, obtaining not conclusive results. To compare the accuracy of test FEES in infants with high suspicion of altered DD seen in a third level hospital with the gold standard Videofluoroscopic (VF). The results and findings by FEES and VF of 66 children with clinical diagnosis of DD were compared. An estimate of the sensitivity and specificity of FEES was performed. As well as calculating positive predictive value (PPV), negative predictive value (NPV) and likelihood ratios. 60 patients enrolled, 4 and FEES showed high sensitivity to identify the presence of aspiration and penetration (9 98%) and high specificity for the arrest of spillage and waste (94% and 95%). Gastroesophageal reflux to make the diagnosis of DD with FEES had a sensitivity of 80% and specificity of 84%. Spill and penetration had the highest agreement with respect to the gold standard of 0.81. FEES in infants diagnosed with DD had a sensitivity of 80.8% and specificity 85.3%. 0696 concordance regarding to the VFD in the diagnosis of DD, and to identify suction stroke had a kappa of 0815.

  7. Approach to the Highly Sensitized Kidney Transplant Candidate

    PubMed Central

    Vranic, Gayle M.

    2016-01-01

    For patients with ESRD, kidney transplant offers significant survival and quality-of-life advantages compared with dialysis. But for patients seeking transplant who are highly sensitized, wait times have traditionally been long and options limited. The approach to the highly sensitized candidate for kidney transplant has changed substantially over time owing to new advances in desensitization, options for paired donor exchange (PDE), and changes to the deceased-donor allocation system. Initial evaluation should focus on determining living-donor availability because a compatible living donor is always the best option. However, for most highly sensitized candidates this scenario is unlikely. For candidates with an incompatible donor, PDE can improve the prospects of finding a compatible living donor but for many highly sensitized patients the probability of finding a match in the relatively small pools of donors in PDE programs is limited. Desensitization of a living donor/recipient pair with low levels of incompatibility is another reasonable approach. But for pairs with high levels of pathologic HLA antibodies, outcomes after desensitization for the patient and allograft are less optimal. Determining the degree of sensitization by calculated panel-reactive antibody (cPRA) is critical in counseling the highly sensitized patient on expected wait times to deceased-donor transplant. For candidates with a high likelihood of finding a compatible deceased donor in a reasonable time frame, waiting for a kidney is a good strategy. For the candidate without a living donor and with a low probability of finding a deceased-donor match, desensitization on the waiting list can be considered. The approach to the highly sensitized kidney transplant candidate must be individualized and requires careful discussion among the transplant center, patient, and referring nephrologist. PMID:26915916

  8. [COMPARATIVE SENSITIVITY OF CHOLINESTERASES IN VERTEBRATES AND INVERTEBRATES TO HIGHLY SPECIFIC ORGANOPHOSPHORUS INHIBITORS DIISOPROPYL FLUOROPHOSPHATE (DFP) AND (2-ETHOXYMETHYL PHOSPHORYL THIOETHYL) ETHYL (METHYL) SULPHONIUM SULPHOMETHYLAT (GD-42)].

    PubMed

    Basova, N E; Kormilitsyn, B N; Perchenok, A Yu; Rozengart, E V; Saakov, V S; Suvorov, A A

    2015-01-01

    The review presents data on comparative reactivity of 68 cholinesterase preparation from various organs and tissues in a number of vertebrates and invertebrates based on sensitivity to two highly specific and most studied organophosphorus inhibitors--diisopropyl fluorophosphates (DFP) and (2-ethoxymethyl phosphoryl thioethyl) ethyl (methyl) sulphonium sulphomethylat (GD-42). Analysis of these data suggests a great diversity in enzymologic characteristics of cholinesterase preparation in representatives of vertebrates and invertebrates, this variety observed even for closely related enzymes in animals of almost the same level of development.

  9. Sensitivity to Envelope Interaural Time Differences at High Modulation Rates

    PubMed Central

    Bleeck, Stefan; McAlpine, David

    2015-01-01

    Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor—to the point of discrimination thresholds being unattainable—compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners’ sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered. PMID:26721926

  10. Influence of environmental temperature on in vivo energy expenditure in vitro ouabain-sensitive respiration in duodenal mucosa and liver in rats fed different levels of dietary fiber or protein.

    PubMed

    Jørgensen, H; Zhao, X Q

    1997-12-01

    Seventy two Wistar rats were used in two repeat studies to investigate the effect of environmental temperature (18 degrees C or 28 degrees C) and increasing levels of dietary fibre (low, 68 g/kg DM; medium 110 g/kg DM; high, 157 g/kg DM) or protein (low, 91 g/kg DM; medium, 171 g/kg DM; high, 262 g/kg DM) on digestive tract, visceral organ size, energy metabolism, and respiration attributable to Na+,K(+)-ATPase activity in duodenal mucosa and liver. Total and ouabain-sensitive (a measure of Na+,K(+)-ATPase activity) O2 consumption in vitro of tissues were measured polarographically using a Clark-style YSI biological O2 monitor. Whole body heat production (in vivo) was measured using open-circuit respiration chambers. The weight of the visceral organs was higher in rats housed at 18 degrees C than at 28 degrees C. The empty weight of the small intestine, caecum, and colon increased as the level of dietary fibre increased (P 0.05). Heat production as a proportion of metabolizable energy was higher (P < 0.05) at 18 degrees C than at 28 degrees C in the first experiment but this difference was significant in the second experiment. Rats fed the low protein diet had significantly higher (P > 0.05) heat production than those fed medium or high protein diets. Compared to 28 degrees C, environmental temperature of 18 degrees C caused an increased total and ouabain-sensitive O2 consumption in duodenal mucosa. There was no significant effect of environmental temperature on total and ouabain-sensitive O2 consumption in the liver. However, ouabain-sensitive O2 consumption in liver was significantly higher (P 0.05) when rats were fed a low protein diet compared to the medium or high protein diet. Total and ouabain-sensitive O2 consumption increased in duodenal mucosa of rats fed low level of dietary fibre compared to the medium or high dietary fibre diets. The in vitro results corresponded with the whole animal energy expenditure and O2 consumption in vivo.

  11. High-sensitivity density fluctuation detector

    NASA Technical Reports Server (NTRS)

    Azzazy, M.; Modarress, D.; Hoeft, T.

    1987-01-01

    A high-sensitivity differential interferometer has been developed to detect small density fluctuations over an optical path length of the order of the boundary layer thickness near transition. Two experimental configurations have been used to evaluate the performance of the interferometer: an open shear-layer configuration and a wind-tunnel turbulent spot configuration. In each experiment small temperature fluctuations were introduced as the signal source. Simultaneous cold-wire measurements have been compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations of the order of 0.001 of the laser wavelength.

  12. Highly sensitive detection of cancer cells using femtosecond dual-wavelength near-IR two-photon imaging.

    PubMed

    Starkey, Jean R; Makarov, Nikolay S; Drobizhev, Mikhail; Rebane, Aleksander

    2012-07-01

    We describe novel imaging protocols that allow detection of small cancer cell colonies deep inside tissue phantoms with high sensitivity and specificity. We compare fluorescence excited in Styryl-9M molecules by femtosecond pulses at near IR wavelengths, where Styryl-9M shows the largest dependence of the two-photon absorption (2PA) cross section on the local environment. We show that by calculating the normalized ratio of the two-photon excited fluorescence (2PEF) intensity at 1200 nm and 1100 nm excitation wavelengths we can achieve high sensitivity and specificity for determining the location of cancer cells surrounded by normal cells. The 2PEF results showed a positive correlation with the levels of MDR1 proteins expressed by the cells, and, for high MDR1 expressors, as few as ten cancer cells could be detected. Similar high sensitivity is also demonstrated for tumor colonies induced in mouse external ears. This technique could be useful in early cancer detection, and, perhaps, also in monitoring dormant cancer deposits.

  13. Eating high fat chow enhances the locomotor-stimulating effects of cocaine in adolescent and adult female rats.

    PubMed

    Baladi, Michelle G; Koek, Wouter; Aumann, Megan; Velasco, Fortino; France, Charles P

    2012-08-01

    Dopamine systems vary through development in a manner that can impact drugs acting on those systems. Dietary factors can also impact the effects of drugs acting on dopamine systems. This study examined whether eating high fat chow alters locomotor effects of cocaine (1-56 mg/kg) in adolescent and adult female rats. Cocaine was studied in rats (n = 6/group) with free access to standard (5.7% fat) or high fat (34.3%) chow or restricted access to high fat chow (body weight matched to rats eating standard chow). After 1 week of eating high fat chow (free or restricted access), sensitivity to cocaine was significantly increased in adolescent and adult rats, compared with rats eating standard chow. Sensitivity to cocaine was also increased in adolescent rats with restricted, but not free, access to high fat chow for 4 weeks. When adolescent and adult rats that previously ate high fat chow ate standard chow, sensitivity to cocaine returned to normal. In adolescent and adult female rats eating high fat chow, but not those eating standard chow, sensitivity to cocaine increased progressively over once weekly tests with cocaine (i.e., sensitization) in a manner that was not statistically different between adolescents and adults. These results show that eating high fat chow alters sensitivity of female rats to acutely administered cocaine and also facilitates the development of sensitization to cocaine. That the type of food consumed can increase drug effects might have relevance to vulnerability to abuse cocaine in the female population.

  14. The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi.

    PubMed

    Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L

    2016-01-01

    Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis.

  15. The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi

    PubMed Central

    Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L.

    2016-01-01

    Background Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. Objective To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Methods Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Results Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). Conclusion The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis. PMID:27171380

  16. Red meat, dairy, and insulin sensitivity: a randomized crossover intervention study.

    PubMed

    Turner, Kirsty M; Keogh, Jennifer B; Clifton, Peter M

    2015-06-01

    Epidemiologic studies have linked high consumption of red and processed meat with risk of developing type 2 diabetes, whereas high dairy consumption has been associated with decreased risk, but interventions have been limited. We compared the effects on insulin sensitivity of consuming a diet high in lean red meat with minimal dairy, a diet high in primarily low-fat dairy (from milk, yogurt, or custard) with no red meat, and a control diet that contained neither red meat nor dairy. A randomized crossover study was undertaken with 47 overweight and obese men and women divided into 2 groups as follows: those with normal glucose tolerance and those with impaired fasting glucose or impaired glucose tolerance. Participants followed the 3 weight-stable dietary interventions for 4 wk with glucose, insulin, and C-peptide measured by using oral-glucose-tolerance tests at the end of each diet. Fasting insulin was significantly higher after the dairy diet than after the red meat diet (P < 0.01) with no change in fasting glucose resulting in a decrease in insulin sensitivity after the high-dairy diet (P < 0.05) as assessed by homeostasis model assessment of insulin resistance (HOMA-IR). A significant interaction between diet and sex was observed such that, in women alone, HOMA-IR was significantly lower after the red meat diet than after the dairy diet (1.33 ± 0.8 compared with 1.71 ± 0.8, respectively; P < 0.01). Insulin sensitivity calculated by using the Matsuda method was 14.7% lower in women after the dairy diet than after the red meat diet (P < 0.01) with no difference between diets in men. C-peptide was not different between diets. In contrast to some epidemiologic findings, these results suggest that high consumption of dairy reduces insulin sensitivity compared with a diet high in lean red meat in overweight and obese subjects, some of whom had glucose intolerance. This trial was registered at the Australian New Zealand Clinical Trials Registry as ACTRN12613000441718. © 2015 American Society for Nutrition.

  17. Supersensitive detection and discrimination of enantiomers by dorsal olfactory receptors: evidence for hierarchical odour coding.

    PubMed

    Sato, Takaaki; Kobayakawa, Reiko; Kobayakawa, Ko; Emura, Makoto; Itohara, Shigeyoshi; Kizumi, Miwako; Hamana, Hiroshi; Tsuboi, Akio; Hirono, Junzo

    2015-09-11

    Enantiomeric pairs of mirror-image molecular structures are difficult to resolve by instrumental analyses. The human olfactory system, however, discriminates (-)-wine lactone from its (+)-form rapidly within seconds. To gain insight into receptor coding of enantiomers, we compared behavioural detection and discrimination thresholds of wild-type mice with those of ΔD mice in which all dorsal olfactory receptors are genetically ablated. Surprisingly, wild-type mice displayed an exquisite "supersensitivity" to enantiomeric pairs of wine lactones and carvones. They were capable of supersensitive discrimination of enantiomers, consistent with their high detection sensitivity. In contrast, ΔD mice showed selective major loss of sensitivity to the (+)-enantiomers. The resulting 10(8)-fold differential sensitivity of ΔD mice to (-)- vs. (+)-wine lactone matched that observed in humans. This suggests that humans lack highly sensitive orthologous dorsal receptors for the (+)-enantiomer, similarly to ΔD mice. Moreover, ΔD mice showed >10(10)-fold reductions in enantiomer discrimination sensitivity compared to wild-type mice. ΔD mice detected one or both of the (-)- and (+)-enantiomers over a wide concentration range, but were unable to discriminate them. This "enantiomer odour discrimination paradox" indicates that the most sensitive dorsal receptors play a critical role in hierarchical odour coding for enantiomer identification.

  18. Supersensitive detection and discrimination of enantiomers by dorsal olfactory receptors: evidence for hierarchical odour coding

    PubMed Central

    Sato, Takaaki; Kobayakawa, Reiko; Kobayakawa, Ko; Emura, Makoto; Itohara, Shigeyoshi; Kizumi, Miwako; Hamana, Hiroshi; Tsuboi, Akio; Hirono, Junzo

    2015-01-01

    Enantiomeric pairs of mirror-image molecular structures are difficult to resolve by instrumental analyses. The human olfactory system, however, discriminates (−)-wine lactone from its (+)-form rapidly within seconds. To gain insight into receptor coding of enantiomers, we compared behavioural detection and discrimination thresholds of wild-type mice with those of ΔD mice in which all dorsal olfactory receptors are genetically ablated. Surprisingly, wild-type mice displayed an exquisite “supersensitivity” to enantiomeric pairs of wine lactones and carvones. They were capable of supersensitive discrimination of enantiomers, consistent with their high detection sensitivity. In contrast, ΔD mice showed selective major loss of sensitivity to the (+)-enantiomers. The resulting 108-fold differential sensitivity of ΔD mice to (−)- vs. (+)-wine lactone matched that observed in humans. This suggests that humans lack highly sensitive orthologous dorsal receptors for the (+)-enantiomer, similarly to ΔD mice. Moreover, ΔD mice showed >1010-fold reductions in enantiomer discrimination sensitivity compared to wild-type mice. ΔD mice detected one or both of the (−)- and (+)-enantiomers over a wide concentration range, but were unable to discriminate them. This “enantiomer odour discrimination paradox” indicates that the most sensitive dorsal receptors play a critical role in hierarchical odour coding for enantiomer identification. PMID:26361056

  19. High sensitivity of contact-heat evoked potentials in "snake-eye" appearance myelopathy.

    PubMed

    Ulrich, A; Min, K; Curt, A

    2015-10-01

    To evaluate the sensitivity of dermatomal contact-heat evoked potentials (dCHEPs) compared to dermatomal somatosensory evoked potentials (dSSEPs) and clinical sensory testing in patients with focal central cord myelopathy, referred to as "snake-eye" appearance myelopathy (SEAM). 33 patients with SEAM in neuroimaging underwent electrophysiological (dCHEPs, dSSEPs) and clinical testing of sensory function (light touch [LT] and pin prick [PP]) at segments above, at and below to the spinal cord lesion. In total, 151 dermatomes were tested (39 above, 112 at/below lesion). The sensitivity of dCHEPs (97.0%) was significantly higher compared to dSSEPs (23.3%, p<0.001), PP (66.7%, p=0.003) and LT (69.7%, p=0.006), respectively. The sensitivity of dCHEPs was highest when applied one to two segments caudally to the level of spinal cord lesion in MRI. dCHEPs are highly sensitive and superior to dSSEPs and clinical sensory testing in the diagnosis of SEAM. dCHEPs may complement the diagnosis in focal central cord myelopathies where clinical testing of sensory function and dSSEPs are less sensitive to provide conclusive findings. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Sensitive and selective determination of methylenedioxylated amphetamines by high-performance liquid chromatography with fluorimetric detection.

    PubMed

    Sadeghipour, F; Veuthey, J L

    1997-11-07

    A rapid, sensitive and selective liquid chromatographic method with fluorimetric detection was developed for the separation and quantification of four methylenedioxylated amphetamines without interference of other drugs of abuse and common substances found in illicit tablets. The method was validated by examining linearity, precision and accuracy as well as detection and quantification limits. Methylenedioxylated amphetamines were quantified in eight tablets from illicit drug seizures and results were quantitatively compared to HPLC-UV analyses. To demonstrate the better sensitivity of the fluorimetric detection, methylenedioxylated amphetamines were analyzed in serum after a liquid-liquid extraction procedure and results were also compared to HPLC-UV analyses.

  1. Pyocin-sensitivity testing as a method of typing Pseudomonas aeruginosa: use of "phage-free" preparations of pyocin.

    PubMed

    Rampling, A; Whitby, J L; Wildy, P

    1975-11-01

    A method for pyocin-sensitivity typing by means of "phage-free" preparations of pyocin is described. The method was tested on 227 isolates of P. aeruginosa, collected from 34 different foci of infection in hospitals in the British Isles and the results were compared with those for combined serological and phage typing of all strains and pyocin production of 105 of the isolates. It is concluded that pyocin-sensitivity typing is a simple and reliable method giving a high degree of discrimination, comparable to that of combined serological and phage typing, and it is suitable for use in routine hospital laboratories.

  2. Dyes designed for high sensitivity detection of double-stranded DNA

    DOEpatents

    Glazer, A.N.; Benson, S.C.

    1998-07-21

    Novel fluorescent dyes are provided, characterized by having a fluorophore joined to a cationic chain. The dyes are found to provide for high enhancement upon binding to nucleic acid and have strong binding affinities to the nucleic acid, as compared to the fluorophore without the polycationic chain. The dyes find use in detection of dsDNA in gel electrophoresis and solution at substantially higher sensitivities using substantially less dye. 10 figs.

  3. Highly Stretchable and Transparent Thermistor Based on Self-Healing Double Network Hydrogel.

    PubMed

    Wu, Jin; Han, Songjia; Yang, Tengzhou; Li, Zhong; Wu, Zixuan; Gui, Xuchun; Tao, Kai; Miao, Jianmin; Norford, Leslie K; Liu, Chuan; Huo, Fengwei

    2018-06-06

    An ultrastretchable thermistor that combines intrinsic stretchability, thermal sensitivity, transparency, and self-healing capability is fabricated. It is found the polyacrylamide/carrageenan double network (DN) hydrogel is highly sensitive to temperature and therefore can be exploited as a novel channel material for a thermistor. This thermistor can be stretched from 0 to 330% strain with the sensitivity as high as 2.6%/°C at extreme 200% strain. Noticeably, the mechanical, electrical, and thermal sensing properties of the DN hydrogel can be self-healed, analogous to the self-healing capability of human skin. The large mechanical deformations, such as flexion and twist with large angles, do not affect the thermal sensitivity. Good flexibility enables the thermistor to be attached on nonplanar curvilinear surfaces for practical temperature detection. Remarkably, the thermal sensitivity can be improved by introducing mechanical strain, making the sensitivity programmable. This thermistor with tunable sensitivity is advantageous over traditional rigid thermistors that lack flexibility in adjusting their sensitivity. In addition to superior sensitivity and stretchability compared with traditional thermistors, this DN hydrogel-based thermistor provides additional advantages of good transparency and self-healing ability, enabling it to be potentially integrated in soft robots to grasp real world information for guiding their actions.

  4. A fully battery-powered inexpensive spectrophotometric system for high-sensitivity point-of-care analysis on a microfluidic chip

    PubMed Central

    Dou, Maowei; Lopez, Juan; Rios, Misael; Garcia, Oscar; Xiao, Chuan; Eastman, Michael

    2016-01-01

    A cost-effective battery-powered spectrophotometric system (BASS) was developed for quantitative point-of-care (POC) analysis on a microfluidic chip. By using methylene blue as a model analyte, we first compared the performance of the BASS with a commercial spectrophotometric system, and further applied the BASS for loop-mediated isothermal amplification (LAMP) detection and subsequent quantitative nucleic acid analysis which exhibited a comparable limit of detection to that of Nanodrop. Compared to the commercial spectrophotometric system, our spectrophotometric system is lower-cost, consumes less reagents, and has a higher detection sensitivity. Most importantly, it does not rely on external power supplies. All these features make our spectrophotometric system highly suitable for a variety of POC analyses, such as field detection. PMID:27143408

  5. Comparing performance of mothers using simplified mid-upper arm circumference (MUAC) classification devices with an improved MUAC insertion tape in Isiolo County, Kenya.

    PubMed

    Grant, Angeline; Njiru, James; Okoth, Edgar; Awino, Imelda; Briend, André; Murage, Samuel; Abdirahman, Saida; Myatt, Mark

    2018-01-01

    A novel approach for improving community case-detection of acute malnutrition involves mothers/caregivers screening their children for acute malnutrition using a mid-upper arm circumference (MUAC) insertion tape. The objective of this study was to test three simple MUAC classification devices to determine whether they improved the sensitivity of mothers/caregivers at detecting acute malnutrition. Prospective, non-randomised, partially-blinded, clinical diagnostic trial describing and comparing the performance of three "Click-MUAC" devices and a MUAC insertion tape. The study took place in twenty-one health facilities providing integrated management of acute malnutrition (IMAM) services in Isiolo County, Kenya. Mothers/caregivers classified their child ( n =1040), aged 6-59 months, using the "Click-MUAC" devices and a MUAC insertion tape. These classifications were compared to a "gold standard" classification (the mean of three measurements taken by a research assistant using the MUAC insertion tape). The sensitivity of mother/caregiver classifications was high for all devices (>93% for severe acute malnutrition (SAM), defined by MUAC < 115 mm, and > 90% for global acute malnutrition (GAM), defined by MUAC < 125 mm). Mother/caregiver sensitivity for SAM and GAM classification was higher using the MUAC insertion tape (100% sensitivity for SAM and 99% sensitivity for GAM) than using "Click-MUAC" devices. Younden's J for SAM classification, and sensitivity for GAM classification, were significantly higher for the MUAC insertion tape (99% and 99% respectively). Specificity was high for all devices (>96%) with no significant difference between the "Click-MUAC" devices and the MUAC insertion tape. The results of this study indicate that, although the "Click-MUAC" devices performed well, the MUAC insertion tape performed best. The results for sensitivity are higher than found in previous studies. The high sensitivity for both SAM and GAM classification by mothers/caregivers with the MUAC insertion tape could be due to the use of an improved MUAC tape design which has a number of new design features. The one-on-one demonstration provided to mothers/caregivers on the use of the devices may also have helped improve sensitivity. The results of this study provide evidence that mothers/caregivers can perform sensitive and specific classifications of their child's nutritional status using MUAC. Clinical trials registration number: NCT02833740.

  6. Delay discounting, risk-taking, and rejection sensitivity among individuals with Internet and Video Gaming Disorders.

    PubMed

    Weinstein, Aviv; Abu, Hodaya Ben; Timor, Ayelet; Mama, Yaniv

    2016-12-01

    Background and aims There is a previous evidence for impulsivity in individuals with Internet and Video Gaming Disorders. The aim of this study was to examine whether Internet and video game addictions are associated with experiential delay discounting, risk-taking, and sensitivity to social rejection using computerized tasks and questionnaires. Methods Twenty participants (mean age 24, SD = 1.55) with high score on the Problematic Online Gaming Questionnaire (POGQ) were compared with 20 participants (mean age 24.8, SD = 1.34) with low score on the POGQ. They performed on computerized Balloon Analog Risk Task and Experiential Delay discounting Task (EDT), and filled in the sensitivity to social rejection questionnaire. Results Participants with high POGQ scores had lower measures of delay discounting, higher measures of risk-taking, and higher measures of sensitivity to social rejection compared with participants with low POGQ scores. Discussion The results of this study support the previous evidence of risk-taking and provide new evidence for difficulties in delay discounting and sensitivity to social rejection among those who score high on Internet and video games. Conclusions The results suggest that Internet- and video game-addicted individuals seek immediate gratification and cannot wait for later reward. Furthermore, these individuals spend time in the virtual world, where they feel safe, and avoid social interactions presumably due to fears of social rejection.

  7. Parenting and adolescents’ psychological adjustment: Longitudinal moderation by adolescents’ genetic sensitivity

    PubMed Central

    Stocker, Clare M.; Masarik, April S.; Widaman, Keith F.; Reeb, Ben T.; Boardman, Jason D.; Smolen, Andrew; Neppl, Tricia K.; Conger, Katherine J.

    2017-01-01

    We examined whether adolescents’ genetic sensitivity, measured by a polygenic index score, moderated the longitudinal associations between parenting and adolescents’ internalizing and externalizing problems. The sample included 323 mothers, fathers, and adolescents (177 female, 146 male; Time 1 [T1] average age = 12.61 [SD = 0.54] years, Time 2 [T2] average age = 13.59 [SD = 0.59] years). Parents’ warmth and hostility were rated by trained, independent observers using videotapes of family discussions. Adolescents reported their symptoms of anxiety, depressed mood, and hostility at T1 and T2. Results from autoregressive linear regression models showed that adolescents’ genetic sensitivity moderated associations between observations of mothers’ T1 parenting and adolescents’ T2 symptoms of depression, anxiety, and hostility. For fathers, the same pattern was found for adolescents’ anxiety and hostility, but not for depressed mood. Compared to adolescents with low genetic sensitivity, adolescents with high genetic sensitivity had worse adjustment outcomes when parenting was low on warmth and high on hostility. When parenting was characterized by high warmth and low hostility, adolescents with high genetic sensitivity had better adjustment outcomes than their counterparts with low genetic sensitivity. Results support the differential susceptibility model and highlight the complex ways that genes and environment interact to influence development. PMID:28027713

  8. Sensitivity, Specificity, and Predictive Values of Pediatric Metabolic Syndrome Components in Relation to Adult Metabolic Syndrome: The Princeton LRC Follow-up Study

    PubMed Central

    Huang, Terry T-K; Nansel, Tonja R.; Belsheim, Allen R.; Morrison, John A.

    2008-01-01

    Objective To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoffs in relation to adult MetS. Study design Data from the NHLBI Lipid Research Clinics (LRC) Princeton Prevalence Study (1973–76) and the Princeton Follow-up Study (PFS, 2000-4) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff, as well as for aggregates of components. Results Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all five pediatric MetS components were considered, the presence of at least one abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Conclusions Considering multiple metabolic variables in childhood can improve the predictive utility for adult MetS, compared to each component or body mass alone. MetS variables may be useful for identifying some at risk children for prevention interventions. PMID:18206687

  9. Trustworthy Tricksters: Violating a Negative Social Expectation Affects Source Memory and Person Perception When Fear of Exploitation Is High

    PubMed Central

    Süssenbach, Philipp; Gollwitzer, Mario; Mieth, Laura; Buchner, Axel; Bell, Raoul

    2016-01-01

    People who are high in victim-sensitivity—a personality trait characterized by a strong fear of being exploited by others—are more likely to attend to social cues associated with untrustworthiness rather than to cues associated with trustworthiness compared with people who are low in victim-sensitivity. But how do these people react when an initial expectation regarding a target’s trustworthiness turns out to be false? Results from two studies show that victim-sensitive compared with victim-insensitive individuals show enhanced source memory and greater change in person perception for negatively labeled targets that violated rather than confirmed negative expectations (the “trustworthy trickster”). These findings are in line with recent theorizing on schema inconsistency and expectancy violation effects in social cognition and with research on the different facets of justice sensitivity in personality psychology. PMID:28082945

  10. Electron-density-sensitive Line Ratios of Fe XIII– XVI from Laboratory Sources Compared to CHIANTI

    NASA Astrophysics Data System (ADS)

    Weller, M. E.; Beiersdorfer, P.; Soukhanovskii, V. A.; Scotti, F.; LeBlanc, B. P.

    2018-02-01

    We present electron-density-sensitive line ratios for Fe XIII– XVI measured in the spectral wavelength range of 200–440 Å and an electron density range of (1–4) × 1013 cm‑3. The results provide a test at the high-density limit of density-sensitive line ratios useful for astrophysical studies. The measurements were performed on the National Spherical Torus Experiment-Upgrade, where electron densities were measured independently by the laser Thomson scattering diagnostic. Spectra were collected with a flat-field grazing-incidence spectrometer, which provided a spectral resolution of up to 0.3 Å, i.e., high resolution across the broad wavelength range. The response of the instrument was relatively calibrated using spectroscopic techniques in order to improve accuracy. The line ratios are compared to other laboratory sources and the latest version of CHIANTI (8.0.2), and an agreement within 30% is found.

  11. Self-estimation or phototest measurement of skin UV sensitivity and its association with people's attitudes towards sun exposure.

    PubMed

    Falk, Magnus

    2014-02-01

    Fitzpatrick's classification is the most common way of assessing skin UV sensitivity. The study aim was to investigate how self-estimated and actual UV sensitivity, as measured by phototest, are associated with attitudes towards sunbathing and the propensity to increase sun protection, as well as the correlation between self-estimated and actual UV sensitivity. A total of 166 primary healthcare patients filled-out a questionnaire investigating attitudes towards sunbathing and the propensity to increase sun protection. They reported their skin type according to Fitzpatrick, and a UV sensitivity phototest was performed. Self-rated low UV sensitivity (skin type III-VI) was associated with a more positive attitude towards sunbathing and a lower propensity to increase sun protection, compared to high UV sensitivity. The correlation between the two methods was weak. The findings might indicate that individuals with a perceived low but in reality high UV sensitivity do not seek adequate sun protection with regard to skin cancer risk. Furthermore, the poor correlation between self-reported and actual UV sensitivity, measured by phototest, makes the clinical use of Fitzpatrick's classification questionable.

  12. The Design and Optimization of a Highly Sensitive and Overload-Resistant Piezoresistive Pressure Sensor

    PubMed Central

    Meng, Xiawei; Zhao, Yulong

    2016-01-01

    A piezoresistive pressure sensor with a beam-membrane-dual-island structure is developed for micro-pressure monitoring in the field of aviation, which requires great sensitivity and overload resistance capacity. The design, fabrication, and test of the sensor are presented in this paper. By analyzing the stress distribution of sensitive elements using the finite element method, a novel structure incorporating sensitive beams with a traditional bossed diaphragm is built up. The proposed structure proved to be advantageous in terms of high sensitivity and high overload resistance compared with the conventional bossed diaphragm and flat diaphragm structures. Curve fittings of surface stress and deflection based on ANSYS simulation results are performed to establish the sensor equations. Fabricated on an n-type single crystal silicon wafer, the sensor chips are wire-bonded to a printed circuit board (PCB) and packaged for experiments. The static and dynamic characteristics are tested and discussed. Experimental results show that the sensor has a sensitivity as high as 17.339 μV/V/Pa in the range of 500 Pa at room temperature, and a high overload resistance of 200 times overpressure. Due to the excellent performance, the sensor can be applied in measuring micro-pressure lower than 500 Pa. PMID:27005627

  13. Self-diagnosis of active head lice infestation by individuals from an impoverished community: high sensitivity and specificity.

    PubMed

    Pilger, Daniel; Khakban, Adak; Heukelbach, Jorg; Feldmeier, Hermann

    2008-01-01

    To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.

  14. Earless toads sense low frequencies but miss the high notes.

    PubMed

    Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A; Chaparro, Juan C; Hoke, Kim L

    2017-10-11

    Sensory losses or reductions are frequently attributed to relaxed selection. However, anuran species have lost tympanic middle ears many times, despite anurans' use of acoustic communication and the benefit of middle ears for hearing airborne sound. Here we determine whether pre-existing alternative sensory pathways enable anurans lacking tympanic middle ears (termed earless anurans) to hear airborne sound as well as eared species or to better sense vibrations in the environment. We used auditory brainstem recordings to compare hearing and vibrational sensitivity among 10 species (six eared, four earless) within the Neotropical true toad family (Bufonidae). We found that species lacking middle ears are less sensitive to high-frequency sounds, however, low-frequency hearing and vibrational sensitivity are equivalent between eared and earless species. Furthermore, extratympanic hearing sensitivity varies among earless species, highlighting potential species differences in extratympanic hearing mechanisms. We argue that ancestral bufonids may have sufficient extratympanic hearing and vibrational sensitivity such that earless lineages tolerated the loss of high frequency hearing sensitivity by adopting species-specific behavioural strategies to detect conspecifics, predators and prey. © 2017 The Author(s).

  15. Polydimethylsiloxane microfluidic chemiluminescence immunodevice with the signal amplification strategy for sensitive detection of human immunoglobin G.

    PubMed

    Li, Huifang; Zhao, Mei; Liu, Wei; Chu, Weiru; Guo, Yumei

    2016-01-15

    A polydimethylsiloxane (PDMS) microfluidic chemiluminescence (CL) immunodevice for sensitive detection of human immunoglobin G (IgG) with the signal amplification strategy was developed in this work. The immunodevice was prepared by covalently immobilizing capture antibodies (Abs) on the silanized microchannel of microfluidic chip. Gold nanoparticles (AuNPs) functionalized with a high molar ratio of horseradish peroxidase (HRP) were used as an Ab label for signal amplification. Using a sandwich immunoassay, the multi-HRP conjugated AuNPs can catalyze the luminol-H2O2 CL system to achieve the high sensitivity. In addition, the double spiral flow-channel was adopted here, which can still contribute to the high sensitivity. Based on signal amplification strategy, the performance of human IgG tests revealed a lower detection limit (DL) of 0.03ng/mL and showed an increase of 7.4-fold in detection sensitivity compared to a commercial Ab-HRP conjugation. This microfluidic immunodevice can provide an alternative approach for sensitive detection of human IgG in the field of clinic diagnostic and therapeutic. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. High-definition vs. standard-definition colonoscopy in the characterization of small colonic polyps: results from a randomized trial.

    PubMed

    Longcroft-Wheaton, G; Brown, J; Cowlishaw, D; Higgins, B; Bhandari, P

    2012-10-01

    The resolution of endoscopes has increased in recent years. Modern Fujinon colonoscopes have a charge-coupled device (CCD) pixel density of 650,000 pixels compared with the 410,000 pixel CCD in standard-definition scopes. Acquiring high-definition scopes represents a significant capital investment and their clinical value remains uncertain. The aim of the current study was to investigate the impact of high-definition endoscopes on the in vivo histology prediction of colonic polyps. Colonoscopy procedures were performed using Fujinon colonoscopes and EPX-4400 processor. Procedures were randomized to be performed using either a standard-definition EC-530 colonoscope or high-definition EC-530 and EC-590 colonoscopes. Polyps of <10 mm were assessed using both white light imaging (WLI) and flexible spectral imaging color enhancement (FICE), and the predicted diagnosis was recorded. Polyps were removed and sent for histological analysis by a pathologist who was blinded to the endoscopic diagnosis. The predicted diagnosis was compared with the histology to calculate the accuracy, sensitivity, and specificity of in vivo assessment using either standard or high-definition scopes. A total of 293 polyps of <10 mm were examined–150 polyps using the standard-definition colonoscope and 143 polyps using high-definition colonoscopes. There was no difference in sensitivity, specificity or accuracy between the two scopes when WLI was used (standard vs. high: accuracy 70% [95% CI 62–77] vs. 73% [95% CI 65–80]; P=0.61). When FICE was used, high-definition colonoscopes showed a sensitivity of 93% compared with 83% for standard-definition colonoscopes (P=0.048); specificity was 81% and 82%, respectively. There was no difference between high- and standard-definition colonoscopes when white light was used, but FICE significantly improved the in vivo diagnosis of small polyps when high-definition scopes were used compared with standard definition.

  17. Comparison of ultrasonic and thermospray systems for high performance sample introduction to inductively coupled plasma atomic emission spectrometry

    NASA Astrophysics Data System (ADS)

    Conver, Timothy S.; Koropchak, John A.

    1995-06-01

    This paper describes detailed work done in our lab to compare analytical figures of merit for pneumatic, ultrasonic and thermospray sample introduction (SI) systems with three different inductively coupled plasma-atomic emission spectrometry (ICP-AES) instruments. One instrument from Leeman Labs, Inc. has an air path echelle spectrometer and a 27 MHz ICP. For low dissolved solid samples with this instrument, we observed that the ultrasonic nebulizer (USN) and fused silica aperture thermospray (FSApT) both offered similar LOD improvements as compared to pneumatic nebulization (PN), 14 and 16 times, respectively. Average sensitivities compared to PN were better for the USN, by 58 times, compared to 39 times for the FSApT. For solutions containing high dissolved solids we observed that FSApT optimized at the same conditions as for low dissolved solids, whereas USN required changes in power and gas flows to maintain a stable discharge. These changes degraded the LODs for USN substantially as compared to those utilized for low dissolved solid solutions, limiting improvement compared to PN to an average factor of 4. In general, sensitivities for USN were degraded at these new conditions. When solutions with 3000 μg/g Ca were analyzed, LOD improvements were smaller for FSApT and USN, but FSApT showed an improvement over USN of 6.5 times. Sensitivities compared to solutions without high dissolved solids were degraded by 19% on average for FSApT, while those for USN were degraded by 26%. The SI systems were also tested with a Varian Instruments Liberty 220 having a vacuum path Czerny-Turner monochromator and a 40 MHz generator. The sensitivities with low dissolved solids solutions compared to PN were 20 times better for the USN and 39 times better for FSApT, and LODs for every element were better for FSApT. Better correlation between relative sensitivities and anticipated relative analyte mass fluxes for FSApT and USN was observed with the Varian instrument. LOD improvements averaged 18 times lower than PN with FSApT while with USN values averaged 8 times lower. When solutions with high dissolved solids were studied it was found that FSApT still offered 5.5 times better LODs than PN and USN offered 4.6 times better LODs than PN. Sensitivities for FSApT averaged 20 times better, while those for USN were 13 times better compared to PN. Finally, background RSDs on the Varian system were generally higher for FSApT than for the USN for similar sample types. A third instrument used for a small set of elements was a Perkin-Elmer model 5500 ICP-AES. This system has a 27 MHz generator with a N 2 purged Czerny-Turner monochromator. LOD trends, background RSDs, and sensitivities were similar to those with the Leeman instrument. However, matrix effects more closely resembled those seen with the Varian instrument for both SI systems. To compare performance and recoveries on a real sample, a National Institute of Standards and Technology, Standard Reference Material 1643c trace elements in water, was analyzed using the Varian system and it was found that both SI systems offered similar recoveries.

  18. Masticatory and cervical muscle tenderness and pain sensitivity in a remote area in subjects with a temporomandibular disorder and neck disability.

    PubMed

    Silveira, Anelise; Armijo-Olivo, Susan; Gadotti, Inae C; Magee, David

    2014-01-01

    To compare the masticatory and cervical muscle tenderness and pain sensitivity in the hand (remote region) between patients with temporomandibular disorders (TMD) and healthy controls. Twenty female subjects were diagnosed with chronic TMD, and 20 were considered healthy. Subjects completed the Neck Disability Index and Limitations of Daily Functions in a TMD questionnaire. Tenderness of the masticatory and cervical muscles and pain sensitivity in the hand were measured using an algometer. Three-way mixed analysis of variance (ANOVA) evaluated differences in muscle tenderness between groups. One-way ANOVA compared pain sensitivity in the hand between groups. Effect sizes were assessed using Cohen guidelines. Significantly increased masticatory and cervical muscle tenderness and pain sensitivity in the hand were found in subjects with TMD when compared with healthy subjects. Moderate to high effect sizes showed the clinical relevance of the findings. The results of this study have highlighted the importance of assessing TMD patients not only in the craniofacial region but also in the neck and other parts of the body. Future studies should focus on testing the effectiveness of treatments addressing the neck and the pain sensitivity in the hand in patients with TMD.

  19. Improved Sensitivity for Molecular Detection of Bacterial and Candida Infections in Blood

    PubMed Central

    Bacconi, Andrea; Richmond, Gregory S.; Baroldi, Michelle A.; Laffler, Thomas G.; Blyn, Lawrence B.; Carolan, Heather E.; Frinder, Mark R.; Toleno, Donna M.; Metzgar, David; Gutierrez, Jose R.; Massire, Christian; Rounds, Megan; Kennel, Natalie J.; Rothman, Richard E.; Peterson, Stephen; Carroll, Karen C.; Wakefield, Teresa; Ecker, David J.

    2014-01-01

    The rapid identification of bacteria and fungi directly from the blood of patients with suspected bloodstream infections aids in diagnosis and guides treatment decisions. The development of an automated, rapid, and sensitive molecular technology capable of detecting the diverse agents of such infections at low titers has been challenging, due in part to the high background of genomic DNA in blood. PCR followed by electrospray ionization mass spectrometry (PCR/ESI-MS) allows for the rapid and accurate identification of microorganisms but with a sensitivity of about 50% compared to that of culture when using 1-ml whole-blood specimens. Here, we describe a new integrated specimen preparation technology that substantially improves the sensitivity of PCR/ESI-MS analysis. An efficient lysis method and automated DNA purification system were designed for processing 5 ml of whole blood. In addition, PCR amplification formulations were optimized to tolerate high levels of human DNA. An analysis of 331 specimens collected from patients with suspected bloodstream infections resulted in 35 PCR/ESI-MS-positive specimens (10.6%) compared to 18 positive by culture (5.4%). PCR/ESI-MS was 83% sensitive and 94% specific compared to culture. Replicate PCR/ESI-MS testing from a second aliquot of the PCR/ESI-MS-positive/culture-negative specimens corroborated the initial findings in most cases, resulting in increased sensitivity (91%) and specificity (99%) when confirmed detections were considered true positives. The integrated solution described here has the potential to provide rapid detection and identification of organisms responsible for bloodstream infections. PMID:24951806

  20. Study of Umbilical Cord Blood Culture in Diagnosis of Early-onset Sepsis Among Newborns with High-risk Factors.

    PubMed

    Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar

    2013-10-01

    Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.

  1. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy: A Prospective, Observational Cohort Study.

    PubMed

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B; Zorumski, Charles F; Conway, Charles; Nagele, Peter

    2017-04-01

    While electroconvulsive therapy is widely regarded as a lifesaving and safe procedure, evidence regarding its effects on myocardial cell injury is sparse. The objective of this investigation was to determine the incidence and magnitude of new cardiac troponin elevation after electroconvulsive therapy using a novel high-sensitivity cardiac troponin I assay. This was a prospective cohort study in adult patients undergoing electroconvulsive therapy in a single academic center (up to three electroconvulsive therapy treatments per patient). The primary outcome was new high-sensitivity cardiac troponin I elevation after electroconvulsive therapy, defined as an increase of high-sensitivity cardiac troponin I greater than 100% after electroconvulsive therapy compared to baseline with at least one value above the limit of quantification (10 ng/l). Twelve-lead electrocardiogram and high-sensitivity cardiac troponin I values were obtained before and 15 to 30 min after electroconvulsive therapy; in a subset of patients, an additional 2-h high-sensitivity cardiac troponin I value was obtained. The final study population was 100 patients and a total of 245 electroconvulsive therapy treatment sessions. Eight patients (8 of 100; 8%) experienced new high-sensitivity cardiac troponin I elevation after electroconvulsive therapy with a cumulative incidence of 3.7% (9 of 245 treatments; one patient had two high-sensitivity cardiac troponin I elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2 of 245; 0.8%). Median high-sensitivity cardiac troponin I concentrations did not increase significantly after electroconvulsive therapy. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of electroconvulsive therapy treatments. Electroconvulsive therapy appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with preexisting cardiovascular risk factors, however, may develop new cardiac troponin elevation after electroconvulsive therapy, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia.

  2. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    PubMed

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  3. High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

    PubMed Central

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-01-01

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885

  4. Beating the Standard Sensitivity-Bandwidth Limit of Cavity-Enhanced Interferometers with Internal Squeezed-Light Generation

    NASA Astrophysics Data System (ADS)

    Korobko, M.; Kleybolte, L.; Ast, S.; Miao, H.; Chen, Y.; Schnabel, R.

    2017-04-01

    The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intracavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations. It is possible to overcome this standard sensitivity-bandwidth limit using nonclassical correlations in the light field. Here, we investigate the internal squeezing approach, where the parametric amplification process creates a nonclassical correlation directly inside the interferometer cavity. We theoretically analyze the limits of the approach and measure 36% increase in the sensitivity-bandwidth product compared to the classical case. To our knowledge, this is the first experimental demonstration of an improvement in the sensitivity-bandwidth product using internal squeezing, opening the way for a new class of optomechanical force sensing devices.

  5. High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA).

    PubMed

    Singh, Harpal; Morita, Takahiro; Suzuki, Yuma; Shimojima, Masayuki; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked immunosorbent assays (ELISA) are considered the gold standard in the demonstration of various immunological reactions with an application in the detection of infectious diseases such as during outbreaks or in patient care. This study aimed to produce an ELISA-based diagnostic with an increased sensitivity of detection compared to the standard 96-well method in the immunologic diagnosis of infectious diseases. A '3DStack' was developed using readily available, low cost fabrication technologies namely nanoimprinting and press stamping with an increased surface area of 4 to 6 times more compared to 96-well plates. This was achieved by stacking multiple nanoimprinted polymer sheets. The flow of analytes between the sheets was enhanced by rotating the 3DStack and confirmed by Finite-Element (FE) simulation. An Immunoglobulin G (IgG) ELISA for the detection of antibodies in human serum raised against Rubella virus was performed for validation. An improved sensitivity of up to 1.9 folds higher was observed using the 3DStack compared to the standard method. The increased surface area of the 3DStack developed using nanoimprinting and press stamping technologies, and the flow pattern between sheets generated by rotating the 3DStack were potential contributors to a more sensitive ELISA-based diagnostic device.

  6. A nano-patterned self assembled monolayer (SAM) rutile titania cancer chip for rapid, low cost, highly sensitive, direct cancer analysis in MALDI-MS.

    PubMed

    Manikandan, M; Gopal, Judy; Hasan, Nazim; Wu, Hui-Fen

    2014-12-01

    We developed a cancer chip by nano-patterning a highly sensitive SAM titanium surface capable of capturing and sensing concentrations as low as 10 cancer cells/mL from the environment by Matrix Assisted Laser Desorption and Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS). The current approach evades any form of pretreatment and sample preparation processes; it is time saving and does not require the (expensive) conventional MALDI target plate. The home made aluminium (Al) target holder cost, on which we loaded the cancer chips for MALDI-TOF MS analysis, is about 60 USD. While the conventional stainless steel MALDI target plate is more than 700 USD. The SAM surface was an effective platform leading to on-chip direct MALDI-MS detection of cancer cells. We compared the functionality of this chip with the unmodified titanium surfaces and thermally oxidized (TO) titanium surfaces. The lowest detectable concentration of the TO chip was 10(3) cells/mL, while the lowest detectable concentration of the control or unmodified titanium chips was 10(6) cells/mL. Compared to the control surface, the SAM cancer chip showed 100,000 times of enhanced sensitivity and compared with the TO chip, 1000 times of increased sensitivity. The high sensitivity of the SAM surfaces is attributed to the presence of the rutile SAM, surface roughness and surface wettability as confirmed by AFM, XRD, contact angle microscope and FE-SEM. This study opens a new avenue for the potent application of the SAM cancer chip for direct cancer diagnosis by MALDI-TOF MS in the near future. Copyright © 2014. Published by Elsevier B.V.

  7. Elucidation of high sensitivity of δ-HMX: New insight from first principles simulations

    NASA Astrophysics Data System (ADS)

    Kuklja, Maija M.; Tsyshevsky, Roman V.; Sharia, Onise

    2017-01-01

    Understanding of a significant difference in sensitivities of β and δ phases of cyclotetramethylene-tetranitramine (HMX) has been long one of the challenges in the field of high energy density materials. Despite many experimental and theoretical efforts to explain the high sensitivity of the δ phase, convincing reasons behind the HMX behavior remained unclear. We established that the presence of a polar surface in δ-HMX has fundamental implications for stability and overall chemical behavior of the material. A comparative quantum-chemical analysis of decomposition mechanisms in polar δ-HMX and nonpolar β-HMX discovered a considerable difference in dominating dissociation reactions, activation barriers, and reaction rates. The polarization-induced charge transfer offered a logical explanation for different sensitivity of β-HMX and δ-HMX polymorphs to detonation initiation. Our conclusions also removed long-standing contradictions and explained a large range of experimental data on thermal decomposition of HMX.

  8. The high-sweet-fat food craving among women with premenstrual dysphoric disorder: emotional response, implicit attitude and rewards sensitivity.

    PubMed

    Yen, Ju-Yu; Chang, Shun-Jen; Ko, Chih-Hung; Yen, Cheng-Fang; Chen, Cheng-Sheng; Yeh, Yi-Chun; Chen, Cheng-Chung

    2010-09-01

    This study aimed to: (1) evaluate food craving and high-sweet-fat food craving across the menstrual cycle; (2) compare the craving and explicit/implicit emotional response to different food; and (3) investigate the reward sensitivity among PMDD and control groups. The PMDD group without treatment history and control group were evaluated for food craving, emotional response to food, implicit attitude task to food, and responsiveness to reward both in luteal and follicular phases. A total of 59 women with PMDD and 60 controls had completed the study. The results revealed that both PMDD diagnosis and luteal phase were associated with higher body mass index. The high-sweet-fat food provoked higher craving, positive emotional, and positive implicit response more than other foods. The luteal phase contributed to higher food and high-sweet-fat food cravings. Besides, the PMDD women had higher reward sensitivity, emotional response, positive implicit attitude, and craving response to high-sweet-fat foods. Further, the rewarding sensitivity was associated with emotional response to high-sweet-fat food which was associated with high-sweet-fat food craving. These results would suggest emotional response and implicit attitude might play a role for high-sweet-fat food craving of PMDD. Further, PMDD women with higher reward sensitivity should be a target group of intervention for high-sweet-fat food craving. Copyright 2010 Elsevier Ltd. All rights reserved.

  9. Exploring the impacts of physics and resolution on aqua-planet simulations from a nonhydrostatic global variable-resolution modeling framework: IMPACTS OF PHYSICS AND RESOLUTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Chun; Leung, L. Ruby; Park, Sang-Hun

    Advances in computing resources are gradually moving regional and global numerical forecasting simulations towards sub-10 km resolution, but global high resolution climate simulations remain a challenge. The non-hydrostatic Model for Prediction Across Scales (MPAS) provides a global framework to achieve very high resolution using regional mesh refinement. Previous studies using the hydrostatic version of MPAS (H-MPAS) with the physics parameterizations of Community Atmosphere Model version 4 (CAM4) found notable resolution dependent behaviors. This study revisits the resolution sensitivity using the non-hydrostatic version of MPAS (NH-MPAS) with both CAM4 and CAM5 physics. A series of aqua-planet simulations at global quasi-uniform resolutionsmore » ranging from 240 km to 30 km and global variable resolution simulations with a regional mesh refinement of 30 km resolution over the tropics are analyzed, with a primary focus on the distinct characteristics of NH-MPAS in simulating precipitation, clouds, and large-scale circulation features compared to H-MPAS-CAM4. The resolution sensitivity of total precipitation and column integrated moisture in NH-MPAS is smaller than that in H-MPAS-CAM4. This contributes importantly to the reduced resolution sensitivity of large-scale circulation features such as the inter-tropical convergence zone and Hadley circulation in NH-MPAS compared to H-MPAS. In addition, NH-MPAS shows almost no resolution sensitivity in the simulated westerly jet, in contrast to the obvious poleward shift in H-MPAS with increasing resolution, which is partly explained by differences in the hyperdiffusion coefficients used in the two models that influence wave activity. With the reduced resolution sensitivity, simulations in the refined region of the NH-MPAS global variable resolution configuration exhibit zonally symmetric features that are more comparable to the quasi-uniform high-resolution simulations than those from H-MPAS that displays zonal asymmetry in simulations inside the refined region. Overall, NH-MPAS with CAM5 physics shows less resolution sensitivity compared to CAM4. These results provide a reference for future studies to further explore the use of NH-MPAS for high-resolution climate simulations in idealized and realistic configurations.« less

  10. Sensitive Detection of Biomolecules by Surface Enhanced Raman Scattering using Plant Leaves as Natural Substrates

    NASA Astrophysics Data System (ADS)

    Sharma, Vipul; Krishnan, Venkata

    2017-03-01

    Detection of biomolecules is highly important for biomedical and other biological applications. Although several methods exist for the detection of biomolecules, surface enhanced Raman scattering (SERS) has a unique role in greatly enhancing the sensitivity. In this work, we have demonstrated the use of natural plant leaves as facile, low cost and eco-friendly SERS substrates for the sensitive detection of biomolecules. Specifically, we have investigated the influence of surface topography of five different plant leaf based substrates, deposited with Au, on the SERS performance by using L-cysteine as a model biomolecule. In addition, we have also compared the effect of sputter deposition of Au thin film with dropcast deposition of Au nanoparticles on the leaf substrates. Our results indicate that L-cysteine could be detected with high sensitivity using these plant leaf based substrates and the leaf possessing hierarchical micro/nanostructures on its surface shows higher SERS enhancement compared to a leaf having a nearplanar surface. Furthermore, leaves with drop-casted Au nanoparticle clusters performed better than the leaves sputter deposited with a thin Au film.

  11. Dyes designed for high sensitivity detection of double-stranded DNA

    DOEpatents

    Glazer, Alexander N.; Benson, Scott C.

    1994-01-01

    Novel fluorescent dyes are provided, characterized by having a fluorophore joined to a polycationic chain of at least two positive charges. The dyes are found to provide for high enhancement upon binding to nucleic acid and have strong binding affinities to the nucleic acid, as compared to the fluorophore without the polycationic chain. The dyes find use in detection of dsDNA in gel electrophoresis and solution at substantially higher sensitivities using substantially less dye.

  12. Conductive fiber-based ultrasensitive textile pressure sensor for wearable electronics.

    PubMed

    Lee, Jaehong; Kwon, Hyukho; Seo, Jungmok; Shin, Sera; Koo, Ja Hoon; Pang, Changhyun; Son, Seungbae; Kim, Jae Hyung; Jang, Yong Hoon; Kim, Dae Eun; Lee, Taeyoon

    2015-04-17

    A flexible and sensitive textile-based pressure sensor is developed using highly conductive fibers coated with dielectric rubber materials. The pressure sensor exhibits superior sensitivity, very fast response time, and high stability, compared with previous textile-based pressure sensors. By using a weaving method, the pressure sensor can be applied to make smart gloves and clothes that can control machines wirelessly as human-machine interfaces. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Polymers imprinted with PAH mixtures--comparing fluorescence and QCM sensors.

    PubMed

    Lieberzeit, Peter A; Halikias, Konstantin; Afzal, Adeel; Dickert, Franz L

    2008-12-01

    Molecular imprinting with binary mixtures of different polycyclic aromatic hydrocarbons (PAH) is a tool for design of chemically highly sensitive layers for detection of these analytes. Sensor responses increase by one order of magnitude compared with layers imprinted with one type of template. Detection limits, e.g. for pyrene, reach down to 30 ng L(-1) in water, as could be observed with a naphthalene and pyrene-imprinted polyurethane. Comparing sensor characteristics obtained by QCM and fluorescence reveals different saturation behaviours indicating that, first, single PAH molecules occupy the interaction centres followed by gradual excimer incorporation at higher concentrations finally leading to substantial quenching, when all accessible cavities are occupied. The plateau in the mass-sensitive measurements suggests that up to 80% of the cavities generated in the MIP are re-occupied. Displacement measurements between chrysene and pyrene revealed that for imprinted layers with very high pyrene sensitivities the signals of both PAH are additive, whereas in materials with lower pyrene uptake the two analytes replace each other in the interaction sites of the polymer.

  14. Cost Effectiveness of Field Trauma Triage among Injured Adults Served by Emergency Medical Services

    PubMed Central

    Newgard, Craig D; Yang, Zhuo; Nishijima, Daniel; McConnell, K John; Trent, Stacy; Holmes, James F; Daya, Mohamud; Mann, N Clay; Hsia, Renee Y; Rea, Tom; Wang, N Ewen; Staudenmayer, Kristan; Delgado, M Kit

    2016-01-01

    Background The American College of Surgeons Committee on Trauma sets national targets for the accuracy of field trauma triage at ≥ 95% sensitivity and ≥ 65% specificity, yet the cost-effectiveness of realizing these goals is unknown. We evaluated the cost-effectiveness of current field trauma triage practices compared to triage strategies consistent with the national targets. Study Design This was a cost-effectiveness analysis using data from 79,937 injured adults transported by 48 emergency medical services (EMS) agencies to 105 trauma and non-trauma hospitals in 6 regions of the Western U.S. from 2006 through 2008. Incremental differences in survival, quality adjusted life years (QALYs), costs, and the incremental cost-effectiveness ratio (ICER; costs per QALY gained) were estimated for each triage strategy over a 1-year and lifetime horizon using a decision analytic Markov model. We considered an ICER threshold of less than $100,000 to be cost-effective. Results For these 6 regions, a high sensitivity triage strategy consistent with national trauma policy (sensitivity 98.6%, specificity 17.1%) would cost $1,317,333 per QALY gained, while current triage practices (sensitivity 87.2%, specificity 64.0%) cost $88,000 per QALY gained compared to a moderate sensitivity strategy (sensitivity 71.2%, specificity 66.5%). Refining EMS transport patterns by triage status improved cost-effectiveness. At the trauma system level, a high-sensitivity triage strategy would save 3.7 additional lives per year at a 1-year cost of $8.78 million, while a moderate sensitivity approach would cost 5.2 additional lives and save $781,616 each year. Conclusions A high-sensitivity approach to field triage consistent with national trauma policy is not cost effective. The most cost effective approach to field triage appears closely tied to triage specificity and adherence to triage-based EMS transport practices. PMID:27178369

  15. Reconstruction-free sensitive wavefront sensor based on continuous position sensitive detectors.

    PubMed

    Godin, Thomas; Fromager, Michael; Cagniot, Emmanuel; Brunel, Marc; Aït-Ameur, Kamel

    2013-12-01

    We propose a new device that is able to perform highly sensitive wavefront measurements based on the use of continuous position sensitive detectors and without resorting to any reconstruction process. We demonstrate experimentally its ability to measure small wavefront distortions through the characterization of pump-induced refractive index changes in laser material. In addition, it is shown using computer-generated holograms that this device can detect phase discontinuities as well as improve the quality of sharp phase variations measurements. Results are compared to reference Shack-Hartmann measurements, and dramatic enhancements are obtained.

  16. Surface plasmon aided high sensitive non-enzymatic glucose sensor using Au/NiAu multilayered nanowire arrays.

    PubMed

    Wang, Lanfang; Zhu, Weiqi; Lu, Wenbo; Qin, Xiufang; Xu, Xiaohong

    2018-07-15

    A novel plasmon aided non-enzymatic glucose sensor was first constructed based on the unique half-rough Au/NiAu multilayered nanowire arrays. These multilayered and half-rough nanowires provide high chemical activity and large surface area for glucose oxidation in an alkaline solution. Under visible light irradiation, the surface plasmons originated from Au part enhance the electron transfer in the vertically aligned nanowires, leading to high sensitivity and wide detection range. The resulting sensor exhibits a wide glucose detection concentration range, low detection limit, and high sensitivity for plasmon aided non-enzymatic glucose sensor. Moreover, the detection sensitivity is enhanced by almost 2 folds compared to that in the dark, which significantly enhanced the performance of Au/NiAu multilayered nanowire arrays sensor. An excellent selectivity and acceptable stability were also achieved. These results indicate that surface plasmon aided nanostructures are promising new platforms for the construction of non-enzymatic glucose sensors. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Fabrication of a highly sensitive penicillin sensor based on charge transfer techniques.

    PubMed

    Lee, Seung-Ro; Rahman, M M; Sawada, Kazuaki; Ishida, Makoto

    2009-03-15

    A highly sensitive penicillin biosensor based on a charge-transfer technique (CTTPS) has been fabricated and demonstrated in this paper. CTTPS comprised a charge accumulation technique for penicilloic acid and H(+) ions perception system. With the proposed CTTPS, it is possible to amplify the sensing signals without external amplifier by using the charge accumulation cycles. The fabricated CTTPS exhibits excellent performance for penicillin detection and exhibit a high-sensitivity (47.852 mV/mM), high signal-to-noise ratio (SNR), large span (1445 mV), wide linear range (0-25 mM), fast response time (<3s), and very good reproducibility. A very lower detection limit of about 0.01 mM was observed from the proposed sensor. Under optimum conditions, the proposed CTTPS outstripped the performance of the widely used ISFET penicillin sensor and exhibited almost eight times greater sensitivity as compared to ISFET (6.56 mV/mM). The sensor system is implemented for the measurement of the penicillin concentration in penicillin fermentation broth.

  18. Development of Fluorescent Polymerization-based Signal Amplification for Sensitive and Non-enzymatic Biodetection in Antibody Microarrays

    PubMed Central

    Avens, Heather J.; Bowman, Christopher N.

    2009-01-01

    Antibody microarrays are a critical tool for proteomics, requiring broad, highly sensitive detection of numerous low abundance biomarkers. Fluorescent polymerization-based amplification (FPBA) is presented as a novel, non-enzymatic signal amplification method that takes advantage of the chain-reaction nature of radical polymerization to achieve a highly amplified fluorescent response. A streptavidin-eosin conjugate localizes eosin photoinitiators for polymerization on the chip where biotinylated target protein is bound. The chip is contacted with acrylamide as a monomer, N-methyldiethanolamine as a coinitiator and yellow/green fluorescent nanoparticles (NPs) which, upon initiation, combine to form a macroscopically visible and highly fluorescent film. The rapid polymerization kinetics and the presence of cross-linker favor entrapment of the fluorescent NPs in the polymer, enabling highly sensitive fluorescent biodetection. This method is demonstrated as being appropriate for antibody microarrays and is compared to detection approaches which utilize streptavidin-FITC (SA-FITC) and streptavidin-labeled yellow/green NPs (SA-NPs). It is found that FPBA is able to detect 0.16 (+/− 0.01) biotin-antibody/µm2 (or 40 zeptomole surface-bound target molecules), while SA-FITC has a limit of detection of 31 (+/− 1) biotin-antibody/µm2 and SA-NPs fail to achieve any significant signal under the conditions evaluated here. Further, FPBA in conjunction with fluorescent stereomicroscopy yields equal or better sensitivity compared to fluorescent detection of SA-eosin using a much more costly microarray scanner. By facilitating highly sensitive detection, FPBA is expected to enable detection of low abundance antigens and also make possible a transition towards less expensive fluorescence detection instrumentation. PMID:19508906

  19. Protein detection system

    DOEpatents

    Fruetel, Julie A [Livermore, CA; Fiechtner, Gregory J [Bethesda, MD; Kliner, Dahv A. V. [San Ramon, CA; McIlroy, Andrew [Livermore, CA

    2009-05-05

    The present embodiment describes a miniature, microfluidic, absorption-based sensor to detect proteins at sensitivities comparable to LIF but without the need for tagging. This instrument utilizes fiber-based evanescent-field cavity-ringdown spectroscopy, in combination with faceted prism microchannels. The combination of these techniques will increase the effective absorption path length by a factor of 10.sup.3 to 10.sup.4 (to .about.1-m), thereby providing unprecedented sensitivity using direct absorption. The coupling of high-sensitivity absorption with high-performance microfluidic separation will enable real-time sensing of biological agents in aqueous samples (including aerosol collector fluids) and will provide a general method with spectral fingerprint capability for detecting specific bio-agents.

  20. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis.

    PubMed

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.

  1. Accurate measurements of cross-plane thermal conductivity of thin films by dual-frequency time-domain thermoreflectance (TDTR)

    NASA Astrophysics Data System (ADS)

    Jiang, Puqing; Huang, Bin; Koh, Yee Kan

    2016-07-01

    Accurate measurements of the cross-plane thermal conductivity Λcross of a high-thermal-conductivity thin film on a low-thermal-conductivity (Λs) substrate (e.g., Λcross/Λs > 20) are challenging, due to the low thermal resistance of the thin film compared with that of the substrate. In principle, Λcross could be measured by time-domain thermoreflectance (TDTR), using a high modulation frequency fh and a large laser spot size. However, with one TDTR measurement at fh, the uncertainty of the TDTR measurement is usually high due to low sensitivity of TDTR signals to Λcross and high sensitivity to the thickness hAl of Al transducer deposited on the sample for TDTR measurements. We observe that in most TDTR measurements, the sensitivity to hAl only depends weakly on the modulation frequency f. Thus, we performed an additional TDTR measurement at a low modulation frequency f0, such that the sensitivity to hAl is comparable but the sensitivity to Λcross is near zero. We then analyze the ratio of the TDTR signals at fh to that at f0, and thus significantly improve the accuracy of our Λcross measurements. As a demonstration of the dual-frequency approach, we measured the cross-plane thermal conductivity of a 400-nm-thick nickel-iron alloy film and a 3-μm-thick Cu film, both with an accuracy of ˜10%. The dual-frequency TDTR approach is useful for future studies of thin films.

  2. Analysis and amelioration about the cross-sensitivity of a high resolution MOEMS accelerometer based on diffraction grating

    NASA Astrophysics Data System (ADS)

    Lu, Qianbo; Bai, Jian; Wang, Kaiwei; Lou, Shuqi; Jiao, Xufen; Han, Dandan

    2016-10-01

    Cross-sensitivity is a crucial parameter since it detrimentally affect the performance of an accelerometer, especially for a high resolution accelerometer. In this paper, a suite of analytical and finite-elements-method (FEM) models for characterizing the mechanism and features of the cross-sensitivity of a single-axis MOEMS accelerometer composed of a diffraction grating and a micromachined mechanical sensing chip are presented, which have not been systematically investigated yet. The mechanism and phenomena of the cross-sensitivity of this type MOEMS accelerometer based on diffraction grating differ quite a lot from the traditional ones owing to the identical sensing principle. By analyzing the models, some ameliorations and the modified design are put forward to suppress the cross-sensitivity. The modified design, achieved by double sides etching on a specific double-substrate-layer silicon-on-insulator (SOI) wafer, is validated to have a far smaller cross-sensitivity compared with the design previously reported in the literature. Moreover, this design can suppress the cross-sensitivity dramatically without compromising the acceleration sensitivity and resolution.

  3. Design and performance evaluation of a new high energy parallel hole collimator for radioiodine planar imaging by gamma cameras: Monte Carlo simulation study.

    PubMed

    Moslemi, Vahid; Ashoor, Mansour

    2017-05-01

    In addition to the trade-off between resolution and sensitivity which is a common problem among all types of parallel hole collimators (PCs), obtained images by high energy PCs (HEPCs) suffer from hole-pattern artifact (HPA) due to further septa thickness. In this study, a new design on the collimator has been proposed to improve the trade-off between resolution and sensitivity and to eliminate the HPA. A novel PC, namely high energy extended PC (HEEPC), is proposed and is compared to HEPCs. In the new PC, trapezoidal denticles were added upon the septa in the detector side. The performance of the HEEPCs were evaluated and compared to that of HEPCs using a Monte Carlo-N-particle version5 (MCNP5) simulation. The point spread functions (PSF) of HEPCs and HEEPCs were obtained as well as the various parameters such as resolution, sensitivity, scattering, and penetration ratios, and the HPA of the collimators was assessed. Furthermore, a Picker phantom study was performed to examine the effects of the collimators on the quality of planar images. It was found that the HEEPC D with an identical resolution to that of HEPC C increased sensitivity by 34.7%, and it improved the trade-off between resolution and sensitivity as well as to eliminate the HPA. In the picker phantom study, the HEEPC D indicated the hot and cold lesions with the higher contrast, lower noise, and higher contrast to noise ratio (CNR). Since the HEEPCs modify the shaping of PSFs, they are able to improve the trade-off between the resolution and sensitivity; consequently, planar images can be achieved with higher contrast resolutions. Furthermore, because the HEEPC S reduce the HPA and produce images with a higher CNR, compared to HEPCs, the obtained images by HEEPCs have a higher quality, which can help physicians to provide better diagnosis.

  4. Sensitivity and specificity of the AdenoPlus point-of-care system in detecting adenovirus in conjunctivitis patients at an ophthalmic emergency department: a diagnostic accuracy study.

    PubMed

    Kam, K Y Ronald; Ong, Hon Shing; Bunce, Catey; Ogunbowale, Lola; Verma, Seema

    2015-09-01

    To estimate the diagnostic accuracy (sensitivity and specificity) of the AdenoPlus point-of-care adenoviral test compared to PCR in an ophthalmic accident and emergency service. These findings were compared with those of a previous study. This was a prospective diagnostic accuracy study on 121 patients presenting to an emergency eye unit with a clinical picture of acute adenoviral conjunctivitis. AdenoPlus testing was carried out on one eye of each patient and a PCR analysis was also performed on a swab taken from the same eye. AdenoPlus and PCR results were interpreted by masked personnel. Sensitivity and specificity for the AdenoPlus test were calculated using PCR results as the reference standard. 121 patients were enrolled and 109 met the inclusion criteria. 43 patients (39.4%) tested positive for adenovirus by PCR analysis. The sensitivity of the AdenoPlus swab in detecting adenovirus was 39.5% (17/43, 95% CI 26% to 54%) and specificity was 95.5% (63/66, 95% CI 87% to 98%) compared to PCR. The AdenoPlus test has a high specificity for diagnosing adenoviral conjunctivitis, but in this clinical setting, we could not reproduce the high sensitivity that has been previously published. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Arterial spin labeling-based Z-maps have high specificity and positive predictive value for neurodegenerative dementia compared to FDG-PET.

    PubMed

    Fällmar, David; Haller, Sven; Lilja, Johan; Danfors, Torsten; Kilander, Lena; Tolboom, Nelleke; Egger, Karl; Kellner, Elias; Croon, Philip M; Verfaillie, Sander C J; van Berckel, Bart N M; Ossenkoppele, Rik; Barkhof, Frederik; Larsson, Elna-Marie

    2017-10-01

    Cerebral perfusion analysis based on arterial spin labeling (ASL) MRI has been proposed as an alternative to FDG-PET in patients with neurodegenerative disease. Z-maps show normal distribution values relating an image to a database of controls. They are routinely used for FDG-PET to demonstrate disease-specific patterns of hypometabolism at the individual level. This study aimed to compare the performance of Z-maps based on ASL to FDG-PET. Data were combined from two separate sites, each cohort consisting of patients with Alzheimer's disease (n = 18 + 7), frontotemporal dementia (n = 12 + 8) and controls (n = 9 + 29). Subjects underwent pseudocontinuous ASL and FDG-PET. Z-maps were created for each subject and modality. Four experienced physicians visually assessed the 166 Z-maps in random order, blinded to modality and diagnosis. Discrimination of patients versus controls using ASL-based Z-maps yielded high specificity (84%) and positive predictive value (80%), but significantly lower sensitivity compared to FDG-PET-based Z-maps (53% vs. 96%, p < 0.001). Among true-positive cases, correct diagnoses were made in 76% (ASL) and 84% (FDG-PET) (p = 0.168). ASL-based Z-maps can be used for visual assessment of neurodegenerative dementia with high specificity and positive predictive value, but with inferior sensitivity compared to FDG-PET. • ASL-based Z-maps yielded high specificity and positive predictive value in neurodegenerative dementia. • ASL-based Z-maps had significantly lower sensitivity compared to FDG-PET-based Z-maps. • FDG-PET might be reserved for ASL-negative cases where clinical suspicion persists. • Findings were similar at two study sites.

  6. Validation of a high-throughput real-time polymerase chain reaction assay for the detection of capripoxviral DNA.

    PubMed

    Stubbs, Samuel; Oura, Chris A L; Henstock, Mark; Bowden, Timothy R; King, Donald P; Tuppurainen, Eeva S M

    2012-02-01

    Capripoxviruses, which are endemic in much of Africa and Asia, are the aetiological agents of economically devastating poxviral diseases in cattle, sheep and goats. The aim of this study was to validate a high-throughput real-time PCR assay for routine diagnostic use in a capripoxvirus reference laboratory. The performance of two previously published real-time PCR methods were compared using commercially available reagents including the amplification kits recommended in the original publication. Furthermore, both manual and robotic extraction methods used to prepare template nucleic acid were evaluated using samples collected from experimentally infected animals. The optimised assay had an analytical sensitivity of at least 63 target DNA copies per reaction, displayed a greater diagnostic sensitivity compared to conventional gel-based PCR, detected capripoxviruses isolated from outbreaks around the world and did not amplify DNA from related viruses in the genera Orthopoxvirus or Parapoxvirus. The high-throughput robotic DNA extraction procedure did not adversely affect the sensitivity of the assay compared to manual preparation of PCR templates. This laboratory-based assay provides a rapid and robust method to detect capripoxviruses following suspicion of disease in endemic or disease-free countries. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  7. Diagnostic accuracy of ultrasound in upper and lower extremity long bone fractures of emergency department trauma patients.

    PubMed

    Frouzan, Arash; Masoumi, Kambiz; Delirroyfard, Ali; Mazdaie, Behnaz; Bagherzadegan, Elnaz

    2017-08-01

    Long bone fractures are common injuries caused by trauma. Some studies have demonstrated that ultrasound has a high sensitivity and specificity in the diagnosis of upper and lower extremity long bone fractures. The aim of this study was to determine the accuracy of ultrasound compared with plain radiography in diagnosis of upper and lower extremity long bone fractures in traumatic patients. This cross-sectional study assessed 100 patients admitted to the emergency department of Imam Khomeini Hospital, Ahvaz, Iran with trauma to the upper and lower extremities, from September 2014 through October 2015. In all patients, first ultrasound and then standard plain radiography for the upper and lower limb was performed. Data were analyzed by SPSS version 21 to determine the specificity and sensitivity. The mean age of patients with upper and lower limb trauma were 31.43±12.32 years and 29.63±5.89 years, respectively. Radius fracture was the most frequent compared to other fractures (27%). Sensitivity, specificity, positive predicted value, and negative predicted value of ultrasound compared with plain radiography in the diagnosis of upper extremity long bones were 95.3%, 87.7%, 87.2% and 96.2%, respectively, and the highest accuracy was observed in left arm fractures (100%). Tibia and fibula fractures were the most frequent types compared to other fractures (89.2%). Sensitivity, specificity, PPV and NPV of ultrasound compared with plain radiography in the diagnosis of upper extremity long bone fractures were 98.6%, 83%, 65.4% and 87.1%, respectively, and the highest accuracy was observed in men, lower ages and femoral fractures. The results of this study showed that ultrasound compared with plain radiography has a high accuracy in the diagnosis of upper and lower extremity long bone fractures.

  8. High-sensitivity detection of breast tumors in vivo by use of a pH-sensitive near-infrared fluorescence probe

    NASA Astrophysics Data System (ADS)

    Mathejczyk, Julia Eva; Pauli, Jutta; Dullin, Christian; Resch-Genger, Ute; Alves, Frauke; Napp, Joanna

    2012-07-01

    We investigated the potential of the pH-sensitive dye, CypHer5E, conjugated to Herceptin (pH-Her) for the sensitive detection of breast tumors in mice using noninvasive time-domain near-infrared fluorescence imaging and different methods of data analysis. First, the fluorescence properties of pH-Her were analyzed as function of pH and/or dye-to-protein ratio, and binding specificity was confirmed in cell-based assays. Subsequently, the performance of pH-Her in nude mice bearing orthotopic HER2-positive (KPL-4) and HER2-negative (MDA-MB-231) breast carcinoma xenografts was compared to that of an always-on fluorescent conjugate Alexa Fluor 647-Herceptin (Alexa-Her). Subtraction of autofluorescence and lifetime (LT)-gated image analyses were performed for background fluorescence suppression. In mice bearing HER2-positive tumors, autofluorescence subtraction together with the selective fluorescence enhancement of pH-Her solely in the tumor's acidic environment provided high contrast-to-noise ratios (CNRs). This led to an improved sensitivity of tumor detection compared to Alexa-Her. In contrast, LT-gated imaging using LTs determined in model systems did not improve tumor-detection sensitivity in vivo for either probe. In conclusion, pH-Her is suitable for sensitive in vivo monitoring of HER2-expressing breast tumors with imaging in the intensity domain and represents a promising tool for detection of weak fluorescent signals deriving from small tumors or metastases.

  9. ELISA-PLA: A novel hybrid platform for the rapid, highly sensitive and specific quantification of proteins and post-translational modifications.

    PubMed

    Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie

    2016-06-15

    Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. New and highly sensitive assay for L-5-hydroxytryptophan decarboxylase activity by high-performance liquid chromatography-voltammetry.

    PubMed

    Rahman, M K; Nagatsu, T; Kato, T

    1980-12-12

    This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.

  11. Skin inspired fractal strain sensors using a copper nanowire and graphite microflake hybrid conductive network.

    PubMed

    Jason, Naveen N; Wang, Stephen J; Bhanushali, Sushrut; Cheng, Wenlong

    2016-09-22

    This work demonstrates a facile "paint-on" approach to fabricate highly stretchable and highly sensitive strain sensors by combining one-dimensional copper nanowire networks with two-dimensional graphite microflakes. This paint-on approach allows for the fabrication of electronic skin (e-skin) patches which can directly replicate with high fidelity the human skin surface they are on, regardless of the topological complexity. This leads to high accuracy for detecting biometric signals for applications in personalised wearable sensors. The copper nanowires contribute to high stretchability and the graphite flakes offer high sensitivity, and their hybrid coating offers the advantages of both. To understand the topological effects on the sensing performance, we utilized fractal shaped elastomeric substrates and systematically compared their stretchability and sensitivity. We could achieve a high stretchability of up to 600% and a maximum gauge factor of 3000. Our simple yet efficient paint-on approach enabled facile fine-tuning of sensitivity/stretchability simply by adjusting ratios of 1D vs. 2D materials in the hybrid coating, and the topological structural designs. This capability leads to a wide range of biomedical sensors demonstrated here, including pulse sensors, prosthetic hands, and a wireless ankle motion sensor.

  12. Genotyping of high-risk anal human papillomavirus (HPV): ion torrent-next generation sequencing vs. linear array.

    PubMed

    Nowak, Rebecca G; Ambulos, Nicholas P; Schumaker, Lisa M; Mathias, Trevor J; White, Ruth A; Troyer, Jennifer; Wells, David; Charurat, Manhattan E; Bentzen, Søren M; Cullen, Kevin J

    2017-06-13

    Our next generation sequencing (NGS)-based human papillomavirus (HPV) genotyping assay showed a high degree of concordance with the Roche Linear Array (LA) with as little as 1.25 ng formalin-fixed paraffin-embedded-derived genomic DNA in head and neck and cervical cancer samples. This sensitive genotyping assay uses barcoded HPV PCR broad-spectrum general primers 5+/6+ (BSGP)5+/6+ applicable to population studies, but it's diagnostic performance has not been tested in cases with multiple concurrent HPV infections. We conducted a cross-sectional study to compare the positive and negative predictive value (PPV and NPV), sensitivity and specificity of the NGS assay to detect HPV genotype infections as compared to the LA. DNA was previously extracted from ten anal swab samples from men who have sex with men in Nigeria enrolled on the TRUST/RV368 cohort study. Two-sample tests of proportions were used to examine differences in the diagnostic performance of the NGS assay to detect high vs. low-risk HPV type-specific infections. In total there were 94 type-specific infections detected in 10 samples with a median of 9.5, range (9 to 10) per sample. Using the LA as the gold standard, 84.4% (95% CI: 75.2-91.2) of the same anal type-specific infections detected on the NGS assay had been detected by LA. The PPV and sensitivity differed significantly for high risk (PPV: 90%, 95% CI: 79.5-96.2; sensitivity: 93.1%, 95% CI: 83.3-98.1) as compared to low risk HPV (PPV: 73%, 95% CI: 54.1-87.7; sensitivity: 61.1, 95% CI: 43.5-76.9) (all p < 0.05). The NPV for all types was 92.5% (95% CI: 88.4-95.4). The NPV and specificity were similar for high and low risk HPVs (all p > 0.05). The NGS assay detected 10 HPV genotypes that were not among the 37 genotypes found on LA (30, 32, 43, 44, 74, 86, 87, 90, 91, 114). The NGS assay accurately detects multiple HPV infections in individual clinical specimens with limited sample volume and has extended coverage compared to LA.

  13. Efficient hiding of confidential high-utility itemsets with minimal side effects

    NASA Astrophysics Data System (ADS)

    Lin, Jerry Chun-Wei; Hong, Tzung-Pei; Fournier-Viger, Philippe; Liu, Qiankun; Wong, Jia-Wei; Zhan, Justin

    2017-11-01

    Privacy preserving data mining (PPDM) is an emerging research problem that has become critical in the last decades. PPDM consists of hiding sensitive information to ensure that it cannot be discovered by data mining algorithms. Several PPDM algorithms have been developed. Most of them are designed for hiding sensitive frequent itemsets or association rules. Hiding sensitive information in a database can have several side effects such as hiding other non-sensitive information and introducing redundant information. Finding the set of itemsets or transactions to be sanitised that minimises side effects is an NP-hard problem. In this paper, a genetic algorithm (GA) using transaction deletion is designed to hide sensitive high-utility itemsets for PPUM. A flexible fitness function with three adjustable weights is used to evaluate the goodness of each chromosome for hiding sensitive high-utility itemsets. To speed up the evolution process, the pre-large concept is adopted in the designed algorithm. It reduces the number of database scans required for verifying the goodness of an evaluated chromosome. Substantial experiments are conducted to compare the performance of the designed GA approach (with/without the pre-large concept), with a GA-based approach relying on transaction insertion and a non-evolutionary algorithm, in terms of execution time, side effects, database integrity and utility integrity. Results demonstrate that the proposed algorithm hides sensitive high-utility itemsets with fewer side effects than previous studies, while preserving high database and utility integrity.

  14. Enhancement of Temporal Resolution and BOLD Sensitivity in Real-Time fMRI using Multi-Slab Echo-Volumar Imaging

    PubMed Central

    Posse, Stefan; Ackley, Elena; Mutihac, Radu; Rick, Jochen; Shane, Matthew; Murray-Krezan, Cristina; Zaitsev, Maxim; Speck, Oliver

    2012-01-01

    In this study, a new approach to high-speed fMRI using multi-slab echo-volumar imaging (EVI) is developed that minimizes geometrical image distortion and spatial blurring, and enables nonaliased sampling of physiological signal fluctuation to increase BOLD sensitivity compared to conventional echo-planar imaging (EPI). Real-time fMRI using whole brain 4-slab EVI with 286 ms temporal resolution (4 mm isotropic voxel size) and partial brain 2-slab EVI with 136 ms temporal resolution (4×4×6 mm3 voxel size) was performed on a clinical 3 Tesla MRI scanner equipped with 12-channel head coil. Four-slab EVI of visual and motor tasks significantly increased mean (visual: 96%, motor: 66%) and maximum t-score (visual: 263%, motor: 124%) and mean (visual: 59%, motor: 131%) and maximum (visual: 29%, motor: 67%) BOLD signal amplitude compared with EPI. Time domain moving average filtering (2 s width) to suppress physiological noise from cardiac and respiratory fluctuations further improved mean (visual: 196%, motor: 140%) and maximum (visual: 384%, motor: 200%) t-scores and increased extents of activation (visual: 73%, motor: 70%) compared to EPI. Similar sensitivity enhancement, which is attributed to high sampling rate at only moderately reduced temporal signal-to-noise ratio (mean: − 52%) and longer sampling of the BOLD effect in the echo-time domain compared to EPI, was measured in auditory cortex. Two-slab EVI further improved temporal resolution for measuring task-related activation and enabled mapping of five major resting state networks (RSNs) in individual subjects in 5 min scans. The bilateral sensorimotor, the default mode and the occipital RSNs were detectable in time frames as short as 75 s. In conclusion, the high sampling rate of real-time multi-slab EVI significantly improves sensitivity for studying the temporal dynamics of hemodynamic responses and for characterizing functional networks at high field strength in short measurement times. PMID:22398395

  15. Functional magnetic resonance imaging activation detection: fuzzy cluster analysis in wavelet and multiwavelet domains.

    PubMed

    Jahanian, Hesamoddin; Soltanian-Zadeh, Hamid; Hossein-Zadeh, Gholam-Ali

    2005-09-01

    To present novel feature spaces, based on multiscale decompositions obtained by scalar wavelet and multiwavelet transforms, to remedy problems associated with high dimension of functional magnetic resonance imaging (fMRI) time series (when they are used directly in clustering algorithms) and their poor signal-to-noise ratio (SNR) that limits accurate classification of fMRI time series according to their activation contents. Using randomization, the proposed method finds wavelet/multiwavelet coefficients that represent the activation content of fMRI time series and combines them to define new feature spaces. Using simulated and experimental fMRI data sets, the proposed feature spaces are compared to the cross-correlation (CC) feature space and their performances are evaluated. In these studies, the false positive detection rate is controlled using randomization. To compare different methods, several points of the receiver operating characteristics (ROC) curves, using simulated data, are estimated and compared. The proposed features suppress the effects of confounding signals and improve activation detection sensitivity. Experimental results show improved sensitivity and robustness of the proposed method compared to the conventional CC analysis. More accurate and sensitive activation detection can be achieved using the proposed feature spaces compared to CC feature space. Multiwavelet features show superior detection sensitivity compared to the scalar wavelet features. (c) 2005 Wiley-Liss, Inc.

  16. [Comparative assessment of MR-semiotics of acutest intracerebral hematomas in low- and extra high-field frequency magnetic resonance tomography].

    PubMed

    Skvortsova, V I; Burenchev, D V; Tvorogova, T V; Guseva, O I; Prokhorov, A V; Smirnov, A M; Kupriianov, D A; Pirogov, Iu A

    2009-01-01

    An objective of the study was to compare sensitivity of low- and extra high-field frequency magnetic resonance (MR) tomography of acutest intracerebral hematomas (ICH) and to assess differences between symptoms in obtained images. A study was conducted using experimental ICH in rats (n=6). Hematomas were formed by two injections of autologic blood into the brain. MR-devices "Bio Spec 70/30" with magnetic field strength of 7 T and "Ellipse-150" with magnetic field strength of 0,15 T were used in the study. MR-tomography was carried out 3-5 h after the injections. Both MR-devices revealed the presence of pathological lesion in all animals. Extra highfield frequency MR-tomography showed the specific signs of ICH caused by the paramagnetic effect of deoxyhemoglobin in T2 and T2*-weighted images (WI) and low frequency MR-tomography - in T2*-WI only. The comparable sensitivity of low- and extra high-field frequency MR-devices in acutest ICH was established.

  17. Linear Response Equilibrium versus echo-planar encoding for fast high-spatial resolution 3D chemical shift imaging

    NASA Astrophysics Data System (ADS)

    Fischer, Rudolf Fritz; Baltes, Christof; Weiss, Kilian; Pazhenkottil, Aju; Rudin, Markus; Boesiger, Peter; Kozerke, Sebastian

    2011-07-01

    In this work Linear Response Equilibrium (LRE) and Echo-planar spectroscopic imaging (EPSI) are compared in terms of sensitivity per unit time and power deposition. In addition an extended dual repetition time scheme to generate broad stopbands for improved inherent water suppression in LRE is presented. The feasibility of LRE and EPSI for assessing cholesterol esters in human carotid plaques with high spatial resolution of 1.95 × 1.15 × 1.15 mm 3 on a clinical 3T MR system is demonstrated. In simulations and phantom experiments it is shown that LRE has comparable but lower sensitivity per unit time relative to EPSI despite stronger signal generated. This relates to the lower sampling efficiency in LRE relative to EPSI as a result of limited gradient performance on clinical MR systems. At the same time, power deposition of LRE is significantly reduced compared to EPSI making it an interesting niche application for in vivo high field spectroscopic imaging of metabolites within a limited bandwidth.

  18. DEER Sensitivity between Iron Centers and Nitroxides in Heme-Containing Proteins Improves Dramatically Using Broadband, High-Field EPR

    PubMed Central

    2016-01-01

    This work demonstrates the feasibility of making sensitive nanometer distance measurements between Fe(III) heme centers and nitroxide spin labels in proteins using the double electron–electron resonance (DEER) pulsed EPR technique at 94 GHz. Techniques to measure accurately long distances in many classes of heme proteins using DEER are currently strongly limited by sensitivity. In this paper we demonstrate sensitivity gains of more than 30 times compared with previous lower frequency (X-band) DEER measurements on both human neuroglobin and sperm whale myoglobin. This is achieved by taking advantage of recent instrumental advances, employing wideband excitation techniques based on composite pulses and exploiting more favorable relaxation properties of low-spin Fe(III) in high magnetic fields. This gain in sensitivity potentially allows the DEER technique to be routinely used as a sensitive probe of structure and conformation in the large number of heme and many other metalloproteins. PMID:27035368

  19. Improved scintimammography using a high-resolution camera mounted on an upright mammography gantry

    NASA Astrophysics Data System (ADS)

    Itti, Emmanuel; Patt, Bradley E.; Diggles, Linda E.; MacDonald, Lawrence; Iwanczyk, Jan S.; Mishkin, Fred S.; Khalkhali, Iraj

    2003-01-01

    99mTc-sestamibi scintimammography (SMM) is a useful adjunct to conventional X-ray mammography (XMM) for the assessment of breast cancer. An increasing number of studies has emphasized fair sensitivity values for the detection of tumors >1 cm, compared to XMM, particularly in situations where high glandular breast densities make mammographic interpretation difficult. In addition, SMM has demonstrated high specificity for cancer, compared to various functional and anatomic imaging modalities. However, large field-of-view (FOV) gamma cameras are difficult to position close to the breasts, which decreases spatial resolution and subsequently, the sensitivity of detection for tumors <1 cm. New dedicated detectors featuring small FOV and increased spatial resolution have recently been developed. In this setting, improvement in tumor detection sensitivity, particularly with regard to small cancers is expected. At Division of Nuclear Medicine, Harbor-UCLA Medical Center, we have performed over 2000 SMM within the last 9 years. We have recently used a dedicated breast camera (LumaGEM™) featuring a 12.8×12.8 cm 2 FOV and an array of 2×2×6 mm 3 discrete crystals coupled to a photon-sensitive photomultiplier tube readout. This camera is mounted on a mammography gantry allowing upright imaging, medial positioning and use of breast compression. Preliminary data indicates significant enhancement of spatial resolution by comparison with standard imaging in the first 10 patients. Larger series will be needed to conclude on sensitivity/specificity issues.

  20. Phase sensitive diffraction sensor for high sensitivity refractive index measurement

    NASA Astrophysics Data System (ADS)

    Kumawat, Nityanand; Varma, Manoj; Kumar, Sunil

    2018-02-01

    In this study a diffraction based sensor has been developed for bio molecular sensing applications and performing assays in real time. A diffraction grating fabricated on a glass substrate produced diffraction patterns both in transmission and reflection when illuminated by a laser diode. We used zeroth order I(0,0) as reference and first order I(0,1) as signal channel and conducted ratiometric measurements that reduced noise by more than 50 times. The ratiometric approach resulted in a very simple instrumentation with very high sensitivity. In the past, we have shown refractive index measurements both for bulk and surface adsorption using the diffractive self-referencing approach. In the current work we extend the same concept to higher diffraction orders. We have considered order I(0,1) and I(1,1) and performed ratiometric measurements I(0,1)/I(1,1) to eliminate the common mode fluctuations. Since orders I(0,1) and I(1,1) behaved opposite to each other, the resulting ratio signal amplitude increased more than twice compared to our previous results. As a proof of concept we used different salt concentrations in DI water. Increased signal amplitude and improved fluid injection system resulted in more than 4 times improvement in detection limit, giving limit of detection 1.3×10-7 refractive index unit (RIU) compared to our previous results. The improved refractive index sensitivity will help significantly for high sensitivity label free bio sensing application in a very cost-effective and simple experimental set-up.

  1. Diminished Sensitivity to Sad Facial Expressions in High Functioning Autism Spectrum Disorders Is Associated with Symptomatology and Adaptive Functioning

    ERIC Educational Resources Information Center

    Wallace, Gregory L.; Case, Laura K.; Harms, Madeline B.; Silvers, Jennifer A.; Kenworthy, Lauren; Martin, Alex

    2011-01-01

    Prior studies implicate facial emotion recognition (FER) difficulties among individuals with autism spectrum disorders (ASD); however, many investigations focus on FER accuracy alone and few examine ecological validity through links with everyday functioning. We compared FER accuracy and perceptual sensitivity (from neutral to full expression)…

  2. Preventing Sexual Risk Behaviors among Gay, Lesbian, and Bisexual Adolescents: The Benefits of Gay-Sensitive HIV Instruction in Schools.

    ERIC Educational Resources Information Center

    Blake, Susan M.; Ledsky, Rebecca; Lehman, Thomas; Goodenow, Carol; Sawyer, Richard; Hack, Tim

    2001-01-01

    Compared the sexual risk taking behaviors of gay, lesbian, and bisexual (GLB) and heterosexual adolescents, evaluating associations between gay-sensitive school HIV instruction and GLB adolescents' risk behaviors. Surveys indicated that GLB students had more high risk behaviors than heterosexual students, and those in schools with gay-sensitive…

  3. Interpersonal sensitivity and functioning impairment in youth at ultra-high risk for psychosis.

    PubMed

    Masillo, A; Valmaggia, L R; Saba, R; Brandizzi, M; Lindau, J F; Solfanelli, A; Curto, M; Narilli, F; Telesforo, L; Kotzalidis, G D; Di Pietro, D; D'Alema, M; Girardi, P; Fiori Nastro, P

    2016-01-01

    A personality trait that often elicits poor and uneasy interpersonal relationships is interpersonal sensitivity. The aim of the present study was to explore the relationship between interpersonal sensitivity and psychosocial functioning in individuals at ultra-high risk for psychosis as compared to help-seeking individuals who screened negative for an ultra-high risk of psychosis. A total sample of 147 adolescents and young adult who were help seeking for emerging mental health problems participated in the study. The sample was divided into two groups: 39 individuals who met criteria for an ultra-high-risk mental state (UHR), and 108 (NS). The whole sample completed the Interpersonal Sensitivity Measure (IPSM) and the Global Functioning: Social and Role Scale (GF:SS; GF:RS). Mediation analysis was used to explore whether attenuated negative symptoms mediated the relationship between interpersonal sensitivity and social functioning. Individuals with UHR state showed higher IPSM scores and lower GF:SS and GF:RS scores than NS participants. A statistically negative significant correlation between two IPSM subscales (Interpersonal Awareness and Timidity) and GF:SS was found in both groups. Our results also suggest that the relationship between the aforementioned aspects of interpersonal sensitivity and social functioning was not mediated by negative prodromal symptoms. This study suggests that some aspects of interpersonal sensitivity were associated with low level of social functioning. Assessing and treating interpersonal sensitivity may be a promising therapeutic target to improve social functioning in young help-seeking individuals.

  4. Detectors for the gamma-ray resonant absorption (GRA) method of explosives detection in cargo: a comparative study

    NASA Astrophysics Data System (ADS)

    Vartsky, David; Goldberg, Mark B.; Engler, Gideon; Shor, Asher; Goldschmidt, Aharon; Feldman, Gennady; Bar, Doron; Orion, Itzhak; Wielopolski, Lucian

    2004-01-01

    Gamma-Ray Resonant Absorption (GRA) is an automatic-decision radiographic screening technique that combines high radiation penetration with very good sensitivity and specificity to nitrogenous explosives. The method is particularly well-suited to inspection of large, massive objects (since the resonant γ-ray probe is at 9.17 MeV) such as aviation and marine containers, heavy vehicles and railroad cars. Two kinds of γ-ray detectors have been employed to date in GRA systems: 1) Resonant-response nitrogen-rich liquid scintillators and 2) BGO detectors. This paper analyses and compares the response of these detector-types to the resonant radiation, in terms of single-pixel figures of merit. The latter are sensitive not only to detector response, but also to accelerator-beam quality, via the properties of the nuclear reaction that produces the resonant-γ-rays. Generally, resonant detectors give rise to much higher nitrogen-contrast sensitivity in the radiographic image than their non-resonant detector counterparts and furthermore, do not require proton beams of high energy-resolution. By comparison, the non-resonant detectors have higher γ-detection efficiency, but their contrast sensitivity is very sensitive to the quality of the accelerator beam. Implications of these detector/accelerator characteristics for eventual GRA field systems are discussed.

  5. Distinct Contributory Factors Determine Basophil-Allergen Sensitivity in Grass Pollen Rhinitis and in Anaphylactic Wasp Venom Allergy.

    PubMed

    Korošec, Peter; Šilar, Mira; Kopač, Peter; Eržen, Renato; Zidarn, Mihaela; Košnik, Mitja

    2016-01-01

    We sought to determine whether basophil-allergen sensitivity could be transferred to donor basophils by passive IgE sensitisation in allergic rhinitis and anaphylactic Hymenoptera venom hypersensitivity. We studied 15 wasp venom-, 19 grass pollen- and 2 house dust mite-allergic patients, 2 healthy donors, and 8 wasp venom-allergic donors. In all subjects, we first evaluated the initial basophil response to wasp venom, grass pollen, or house dust mite allergen. Donor basophils were then stripped, sensitised with the different patients' serum IgE, and challenged with the corresponding allergen. The CD63 response of donor basophils was then compared with initial basophil responses. In wasp venom-allergic subjects, the IgE transfer did not reflect the initial basophil-allergen sensitivity, because the venom IgE of subjects with high or low basophil sensitivity induced comparable responsiveness in healthy donor basophils. Furthermore, vice versa, when we sensitised the donor basophils of wasp venom-allergic individuals with different wasp venom or house dust mite IgE, we demonstrated that their response was predictable by their initial basophil allergen sensitivity. In the rhinitis allergy model, the IgE transfer correlated with the patients' initial basophil responsiveness because the grass pollen IgE of the subjects with high basophil allergen sensitivity induced significantly higher responsiveness of donor basophils than the IgE of subjects with initially low basophil allergen sensitivity. Our results suggest that basophil allergen sensitivity evaluated by flow-cytometric CD63 analysis depends on two distinct contribution factors. In anaphylactic Hymenoptera allergy, the major factor was intrinsic cellular sensitivity, whereas in pollen allergy, the major factor was allergen-specific IgE on the cell surface. © 2016 S. Karger AG, Basel.

  6. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

    PubMed

    Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa

    2017-01-17

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.

  7. NO2 sensing at room temperature using vertically aligned MoS2 flakes network

    NASA Astrophysics Data System (ADS)

    Kumar, Rahul; Goel, Neeraj; Kumar, Mahesh

    2018-04-01

    To exploit the role of alignment of MoS2 flake in chemical sensing, here, we have synthesized the horizontally and vertically aligned MoS2 flake network using conventional chemical vapor deposition technique. The morphology and number of layers were confirmed by SEM and Raman spectroscopy, respectively. The sensing performance of horizontally aligned and vertically aligned flake network was investigated to NO2 at room temperature. Vertically aligned MoS2 based sensor showed higher sensitivity 51.54 % and 63.2 % compared to horizontally aligned MoS2 sensor' sensitivity of 35.32 % and 45.2 % to 50 ppm and 100 ppm NO2, respectively. This high sensitivity attributed to the high aspect ratio and high adsorption energy on the edge site of vertically aligned MoS2.

  8. Long-term rates of mitochondrial protein synthesis are increased in mouse skeletal muscle with high-fat feeding regardless of insulin-sensitizing treatment.

    PubMed

    Newsom, Sean A; Miller, Benjamin F; Hamilton, Karyn L; Ehrlicher, Sarah E; Stierwalt, Harrison D; Robinson, Matthew M

    2017-11-01

    Skeletal muscle mitochondrial protein synthesis is regulated in part by insulin. The development of insulin resistance with diet-induced obesity may therefore contribute to impairments to protein synthesis and decreased mitochondrial respiration. Yet the impact of diet-induced obesity and insulin resistance on mitochondrial energetics is controversial, with reports varying from decreases to increases in mitochondrial respiration. We investigated the impact of changes in insulin sensitivity on long-term rates of mitochondrial protein synthesis as a mechanism for changes to mitochondrial respiration in skeletal muscle. Insulin resistance was induced in C57BL/6J mice using 4 wk of a high-fat compared with a low-fat diet. For 8 additional weeks, diets were enriched with pioglitazone to restore insulin sensitivity compared with nonenriched control low-fat or high-fat diets. Skeletal muscle mitochondrial protein synthesis was measured using deuterium oxide labeling during weeks 10-12 High-resolution respirometry was performed using palmitoyl-l-carnitine, glutamate+malate, and glutamate+malate+succinate as substrates for mitochondria isolated from quadriceps. Mitochondrial protein synthesis and palmitoyl- l-carnitine oxidation were increased in mice consuming a high-fat diet, regardless of differences in insulin sensitivity with pioglitazone treatment. There was no effect of diet or pioglitazone treatment on ADP-stimulated respiration or H 2 O 2 emission using glutamate+malate or glutamate+malate+succinate. The results demonstrate no impairments to mitochondrial protein synthesis or respiration following induction of insulin resistance. Instead, mitochondrial protein synthesis was increased with a high-fat diet and may contribute to remodeling of the mitochondria to increase lipid oxidation capacity. Mitochondrial adaptations with a high-fat diet appear driven by nutrient availability, not intrinsic defects that contribute to insulin resistance. Copyright © 2017 the American Physiological Society.

  9. Anxiety sensitivity and medication nonadherence in patients with uncontrolled hypertension.

    PubMed

    Alcántara, Carmela; Edmondson, Donald; Moise, Nathalie; Oyola, Desiree; Hiti, David; Kronish, Ian M

    2014-10-01

    Anxiety sensitivity-fear of the negative social, physical, or cognitive consequences of anxiety related sensations-has been linked to cardiovascular disease and adverse cardiovascular health behaviors. Medication nonadherence may account for this association. We examined whether anxiety sensitivity was independently associated with objectively measured medication nonadherence in a multi-ethnic primary care sample. Eighty-eight patients with uncontrolled hypertension completed the Anxiety Sensitivity Index and had their adherence to blood pressure (BP) medications measured during the interval between two primary care visits using an electronic pillbox (MedSignals®). Multivariable Poisson regressions were conducted to determine the relative risks of medication nonadherence associated with anxiety sensitivity after adjustment for age, gender, Hispanic/Latino ethnicity, education, total number of prescribed medications, and depressive and posttraumatic stress disorder (PTSD) symptoms. Nearly twice as many patients with high anxiety sensitivity were nonadherent to BP medications compared to patients with low anxiety sensitivity (65.0% vs. 36.8%; p=0.03). Patients with high anxiety sensitivity had higher relative risks of medication nonadherence than their low anxiety sensitivity counterparts (adjusted relative risk [RR]=1.76; 95% CI: 1.03-3.03). In this first study of the association between anxiety sensitivity and medication adherence, we found that high anxiety sensitivity was strongly associated with BP medication nonadherence, even after adjustment for known confounders. Our results suggest that teaching patients who have uncontrolled hypertension adaptive strategies to manage their anxiety sensitivity may help improve their medication adherence, and thereby lower their cardiovascular risk. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. High intensity ion beams from an atmospheric pressure inductively coupled plasma

    NASA Astrophysics Data System (ADS)

    Al Moussalami, S.; Chen, W.; Collings, B. A.; Douglas, D. J.

    2002-02-01

    This work is directed towards substantially improving the sensitivity of an inductively coupled plasma mass spectrometer (ICP-MS). Ions produced in the ICP at atmospheric pressure have been extracted with comparatively high current densities. The conventional approach to ion extraction, based on a skimmed molecular beam, has been abandoned, and a high extraction field arrangement has been adopted. Although the new approach is not optimized, current densities more than 180 times greater than that of a conventional interface have been extracted and analyte sensitivities ˜10-100× greater than those reported previously for quadrupole ICP-MS have been measured.

  11. Influence of the composite material thermal expansion on embedded highly birefringent polymer microstructured optical fibers

    NASA Astrophysics Data System (ADS)

    SzelÄ g, M.; Lesiak, P.; Kuczkowski, M.; Domański, A. W.; Woliński, T. R.

    2013-05-01

    Results of our research on embedded highly birefringent polymer microstructured fibers are presented. A composite material sample with fibers embedded between two layers of a multi-layer composite structure is fabricated and characterized. Temperature sensitivities of the polymer fibers are measured in a free space and compared with the fibers embedded in the composite material. It appeared that highly birefringent polymer microstructured fibers exhibit a strong increase in temperature sensitivity when embedded in the composite material, which is due to the stress-induced changes in birefringence created by thermally-induced strain.

  12. Bent optical fiber tapers for refractometery and biosensing

    NASA Astrophysics Data System (ADS)

    Penchev, Emil; Eftimov, Tinko; Bock, Wojtek

    2015-01-01

    We report the results of our study of the spectral shifts caused by surrounding refractive index changes (SRI) in bent fibre tapers. Fused and etched fibre tapers were fabricated using a gas burner and HF acid. Spectral shifts as high as 200 nm have been observed for SRI variations from 1.33 to 1.44 and sensitivity as high as 830 nm/r.i.u. around water RI values. We present results for refractometric measurements of cow milk of varying fat content and compare results with those obtained with conventional Abbe refractometers and high sensitivity double resonance LPGs.

  13. Towards high-throughput molecular detection of Plasmodium: new approaches and molecular markers

    PubMed Central

    Steenkeste, Nicolas; Incardona, Sandra; Chy, Sophy; Duval, Linda; Ekala, Marie-Thérèse; Lim, Pharath; Hewitt, Sean; Sochantha, Tho; Socheat, Doung; Rogier, Christophe; Mercereau-Puijalon, Odile; Fandeur, Thierry; Ariey, Frédéric

    2009-01-01

    Background Several strategies are currently deployed in many countries in the tropics to strengthen malaria control toward malaria elimination. To measure the impact of any intervention, there is a need to detect malaria properly. Mostly, decisions still rely on microscopy diagnosis. But sensitive diagnosis tools enabling to deal with a large number of samples are needed. The molecular detection approach offers a much higher sensitivity, and the flexibility to be automated and upgraded. Methods Two new molecular methods were developed: dot18S, a Plasmodium-specific nested PCR based on the 18S rRNA gene followed by dot-blot detection of species by using species-specific probes and CYTB, a Plasmodium-specific nested PCR based on cytochrome b gene followed by species detection using SNP analysis. The results were compared to those obtained with microscopic examination and the "standard" 18S rRNA gene based nested PCR using species specific primers. 337 samples were diagnosed. Results Compared to the microscopy the three molecular methods were more sensitive, greatly increasing the estimated prevalence of Plasmodium infection, including P. malariae and P. ovale. A high rate of mixed infections was uncovered with about one third of the villagers infected with more than one malaria parasite species. Dot18S and CYTB sensitivity outranged the "standard" nested PCR method, CYTB being the most sensitive. As a consequence, compared to the "standard" nested PCR method for the detection of Plasmodium spp., the sensitivity of dot18S and CYTB was respectively 95.3% and 97.3%. Consistent detection of Plasmodium spp. by the three molecular methods was obtained for 83% of tested isolates. Contradictory results were mostly related to detection of Plasmodium malariae and Plasmodium ovale in mixed infections, due to an "all-or-none" detection effect at low-level parasitaemia. Conclusion A large reservoir of asymptomatic infections was uncovered using the molecular methods. Dot18S and CYTB, the new methods reported herein are highly sensitive, allow parasite DNA extraction as well as genus- and species-specific diagnosis of several hundreds of samples, and are amenable to high-throughput scaling up for larger sample sizes. Such methods provide novel information on malaria prevalence and epidemiology and are suited for active malaria detection. The usefulness of such sensitive malaria diagnosis tools, especially in low endemic areas where eradication plans are now on-going, is discussed in this paper. PMID:19402894

  14. High hunger state increases olfactory sensitivity to neutral but not food odors.

    PubMed

    Stafford, Lorenzo D; Welbeck, Kimberley

    2011-01-01

    Understanding how hunger state relates to olfactory sensitivity has become more urgent due to their possible role in obesity. In 2 studies (within-subjects: n = 24, between-subjects: n = 40), participants were provided with lunch before (satiated state) or after (nonsatiated state) testing and completed a standardized olfactory threshold test to a neutral odor (Experiments 1 and 2) and discrimination test to a food odor (Experiment 2). Experiment 1 revealed that olfactory sensitivity was greater in the nonsatiated versus satiated state, with additionally increased sensitivity for the low body mass index (BMI) compared with high BMI group. Experiment 2 replicated this effect for neutral odors, but in the case of food odors, those in a satiated state had greater acuity. Additionally, whereas the high BMI group had higher acuity to food odors in the satiated versus nonsatiated state, no such differences were found for the low BMI group. The research here is the first to demonstrate how olfactory acuity changes as a function of hunger state and relatedness of odor to food and that BMI can predict differences in olfactory sensitivity.

  15. Sensitivity of echo enabled harmonic generation to sinusoidal electron beam energy structure

    DOE PAGES

    Hemsing, E.; Garcia, B.; Huang, Z.; ...

    2017-06-19

    Here, we analytically examine the bunching factor spectrum of a relativistic electron beam with sinusoidal energy structure that then undergoes an echo-enabled harmonic generation (EEHG) transformation to produce high harmonics. The performance is found to be described primarily by a simple scaling parameter. The dependence of the bunching amplitude on fluctuations of critical parameters is derived analytically, and compared with simulations. Where applicable, EEHG is also compared with high gain harmonic generation (HGHG) and we find that EEHG is generally less sensitive to several types of energy structure. In the presence of intermediate frequency modulations like those produced by themore » microbunching instability, EEHG has a substantially narrower intrinsic bunching pedestal.« less

  16. High-sensitivity fiber optic acoustic sensors

    NASA Astrophysics Data System (ADS)

    Lu, Ping; Liu, Deming; Liao, Hao

    2016-11-01

    Due to the overwhelming advantages compared with traditional electronicsensors, fiber-optic acoustic sensors have arisen enormous interest in multiple disciplines. In this paper we present the recent research achievements of our group on fiber-optic acoustic sensors. The main point of our research is high sensitivity interferometric acoustic sensors, including Michelson, Sagnac, and Fabry-Pérot interferometers. In addition, some advanced technologies have been proposed for acoustic or acoustic pressure sensing such as single-mode/multimode fiber coupler, dual FBGs and multi-longitudinal mode fiber laser based acoustic sensors. Moreover, our attention we have also been paid on signal demodulation schemes. The intensity-based quadrature point (Q-point) demodulation, two-wavelength quadrature demodulation and symmetric 3×3 coupler methodare discussed and compared in this paper.

  17. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    PubMed Central

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept. PMID:28856047

  18. Rats bred for high alcohol drinking are more sensitive to delayed and probabilistic outcomes.

    PubMed

    Wilhelm, C J; Mitchell, S H

    2008-10-01

    Alcoholics and heavy drinkers score higher on measures of impulsivity than nonalcoholics and light drinkers. This may be because of factors that predate drug exposure (e.g. genetics). This study examined the role of genetics by comparing impulsivity measures in ethanol-naive rats selectively bred based on their high [high alcohol drinking (HAD)] or low [low alcohol drinking (LAD)] consumption of ethanol. Replicates 1 and 2 of the HAD and LAD rats, developed by the University of Indiana Alcohol Research Center, completed two different discounting tasks. Delay discounting examines sensitivity to rewards that are delayed in time and is commonly used to assess 'choice' impulsivity. Probability discounting examines sensitivity to the uncertain delivery of rewards and has been used to assess risk taking and risk assessment. High alcohol drinking rats discounted delayed and probabilistic rewards more steeply than LAD rats. Discount rates associated with probabilistic and delayed rewards were weakly correlated, while bias was strongly correlated with discount rate in both delay and probability discounting. The results suggest that selective breeding for high alcohol consumption selects for animals that are more sensitive to delayed and probabilistic outcomes. Sensitivity to delayed or probabilistic outcomes may be predictive of future drinking in genetically predisposed individuals.

  19. Incorporation of beams into bossed diaphragm for a high sensitivity and overload micro pressure sensor

    NASA Astrophysics Data System (ADS)

    Yu, Zhongliang; Zhao, Yulong; Sun, Lu; Tian, Bian; Jiang, Zhuangde

    2013-01-01

    The paper presents a piezoresistive absolute micro pressure sensor, which is of great benefits for altitude location. In this investigation, the design, fabrication, and test of the sensor are involved. By analyzing the stress distribution of sensitive elements using finite element method, a novel structure through the introduction of sensitive beams into traditional bossed diaphragm is built up. The proposed configuration presents its advantages in terms of high sensitivity and high overload resistance compared with the conventional bossed diaphragm and flat diaphragm structures. Curve fittings of surface stress and deflection based on ANSYS simulation results are performed to establish the equations about the sensor. Nonlinear optimization by MATLAB is carried out to determine the structure dimensions. The output signals in both static and dynamic environments are evaluated. Silicon bulk micromachining technology is utilized to fabricate the sensor prototype, and the fabrication process is discussed. Experimental results demonstrate the sensor features a high sensitivity of 11.098 μV/V/Pa in the operating range of 500 Pa at room temperature, and a high overload resistance of 200 times overpressure to promise its survival under atmosphere. Due to the excellent performance above, the sensor can be applied in measuring the absolute micro pressure lower than 500 Pa.

  20. Transparent, Flexible, Conformal Capacitive Pressure Sensors with Nanoparticles.

    PubMed

    Kim, Hyeohn; Kim, Gwangmook; Kim, Taehoon; Lee, Sangwoo; Kang, Donyoung; Hwang, Min-Soo; Chae, Youngcheol; Kang, Shinill; Lee, Hyungsuk; Park, Hong-Gyu; Shim, Wooyoung

    2018-02-01

    The fundamental challenge in designing transparent pressure sensors is the ideal combination of high optical transparency and high pressure sensitivity. Satisfying these competing demands is commonly achieved by a compromise between the transparency and usage of a patterned dielectric surface, which increases pressure sensitivity, but decreases transparency. Herein, a design strategy for fabricating high-transparency and high-sensitivity capacitive pressure sensors is proposed, which relies on the multiple states of nanoparticle dispersity resulting in enhanced surface roughness and light transmittance. We utilize two nanoparticle dispersion states on a surface: (i) homogeneous dispersion, where each nanoparticle (≈500 nm) with a size comparable to the visible light wavelength has low light scattering; and (ii) heterogeneous dispersion, where aggregated nanoparticles form a micrometer-sized feature, increasing pressure sensitivity. This approach is experimentally verified using a nanoparticle-dispersed polymer composite, which has high pressure sensitivity (1.0 kPa -1 ), and demonstrates excellent transparency (>95%). We demonstrate that the integration of nanoparticle-dispersed capacitor elements into an array readily yields a real-time pressure monitoring application and a fully functional touch device capable of acting as a pressure sensor-based input device, thereby opening up new avenues to establish processing techniques that are effective on the nanoscale yet applicable to macroscopic processing. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    PubMed Central

    Ito, Hiromichi; Matsushita, Shonosuke; Hyodo, Kazuyuki; Sato, Yukio; Sakakibara, Yuzuru

    2013-01-01

    Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity. PMID:23412496

  2. A theoretical-experimental methodology for assessing the sensitivity of biomedical spectral imaging platforms, assays, and analysis methods.

    PubMed

    Leavesley, Silas J; Sweat, Brenner; Abbott, Caitlyn; Favreau, Peter; Rich, Thomas C

    2018-01-01

    Spectral imaging technologies have been used for many years by the remote sensing community. More recently, these approaches have been applied to biomedical problems, where they have shown great promise. However, biomedical spectral imaging has been complicated by the high variance of biological data and the reduced ability to construct test scenarios with fixed ground truths. Hence, it has been difficult to objectively assess and compare biomedical spectral imaging assays and technologies. Here, we present a standardized methodology that allows assessment of the performance of biomedical spectral imaging equipment, assays, and analysis algorithms. This methodology incorporates real experimental data and a theoretical sensitivity analysis, preserving the variability present in biomedical image data. We demonstrate that this approach can be applied in several ways: to compare the effectiveness of spectral analysis algorithms, to compare the response of different imaging platforms, and to assess the level of target signature required to achieve a desired performance. Results indicate that it is possible to compare even very different hardware platforms using this methodology. Future applications could include a range of optimization tasks, such as maximizing detection sensitivity or acquisition speed, providing high utility for investigators ranging from design engineers to biomedical scientists. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Enhancement of NH3 gas sensitivity at room temperature by carbon nanotube-based sensor coated with Co nanoparticles.

    PubMed

    Nguyen, Lich Quang; Phan, Pho Quoc; Duong, Huyen Ngoc; Nguyen, Chien Duc; Nguyen, Lam Huu

    2013-01-30

    Multi-walled carbon nanotube (MWCNT) film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH(3) gas sensing applications. The MWCNT-based sensor is sensitive to NH(3) gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH(3), compared with alcohol and LPG.

  4. Immunohistochemistry and Polymerase Chain Reaction for Detection Human Papilloma Virus in Warts: A Comparative Study

    PubMed Central

    Lee, Hong Sun; Lee, Ji Hyun; Choo, Ji Yoon; Byun, Hee Jin; Jun, Jin Hyun

    2016-01-01

    Background Immunohistochemistry and polymerase chain reaction (PCR) are the most widely used methods for the detection of viruses. PCR is known to be a more sensitive and specific method than the immunohistochemical method at this time, but PCR has the disadvantages of high cost and skilled work to use widely. With the progress of technology, the immunohistochemical methods used in these days has come to be highly sensitive and actively used in the diagnostic fields. Objective To evaluate and compare the usefulness of immunohistochemistry and PCR for detection human papilloma virus (HPV) in wart lesions. Methods Nine biopsy samples of verruca vulgaris and 10 of condyloma accuminatum were examined. Immunohistochemical staining using monoclonal antibody to HPV L1 capsid protein and PCR were done for the samples. DNA sequencing of the PCR products and HPV genotyping were also done. Results HPV detection rate was 78.9% (88.9% in verruca vulgaris, 70.0% in condyloma accuminatum) on immunohistochemistry and 100.0% for PCR. HPV-6 genotype showed a lower positivity rate on immunohistochemistry (50.0%) as compared to that of the other HPV genotypes. Conclusion Immunohistochemistry for HPV L1 capsid protein showed comparable sensitivity for detection HPV. Considering the high cost and great effort needed for the PCR methods, we can use immunohistochemistry for HPV L1 capsid protein with the advantage of lower cost and simple methods for HPV detection. PMID:27489431

  5. One-stop shop whole-body 68Ga-PSMA-11 PET/MRI compared to clinical Nomograms for preoperative T- and N-Staging of High-Risk Prostate Cancer.

    PubMed

    Thalgott, Mark; Düwel, Charlotte; Rauscher, Isabel; Heck, Matthias M; Haller, Bernhard; Gafita, Andrei; Gschwend, Jürgen E; Schwaiger, Markus; Maurer, Tobias; Eiber, Matthias

    2018-05-24

    Our aim was to assess the diagnostic potential of one-stop shop Prostate-specific membrane antigen-ligand Positron Emission Tomography/Magnetic Resonance Imaging ( 68 Ga-PSMA-11 PET/MRI) compared to preoperative staging nomograms in patients with high-risk prostate cancer (PC). Methods: A total of 102 patients underwent 68 Ga-PSMA-11 PET/MRI before intended radical prostatectomy (RP) with lymph node dissection. Preoperative variables determined the probabilities for lymph node metastases (LNM), extracapsular extension (ECE) and seminal vesical involvement (SVI) using the Memorial Sloan-Kettering Cancer Center (MSKCC) nomogram and Partin tables. Receiver operating characteristic (ROC) analyses were performed to determine best discriminatory cutoffs. On cohort base, positivity rates of imaging and nomograms were compared to pathological prevalence. On patient base, sensitivity, specificity and its area under the curves (AUCs) were calculated. Finally, the full concordance of each method to postoperative T- and N-stage was determined. Results: 73 patients were finally analysed. On cohort base, the MSKCC nomogram (39.7%) positivity rate was most concordant with pathological prevalence for LNM (34.3%) compared to Partin tables (14.1%) and imaging (20.6). Prevalence of ECE (72.6%) was best predicted by MSKCC nomograms and imaging (83.6% each), compared to Partin tables (38.4%). For prevalence of SVI (45.2%), imaging (47.9%) performed superior to MSKCC (37.6%) and Partin tables (19.3%). On patient base, AUCs for LNM, ECE and SVI did not differ significantly between tests (p>0.05). Imaging revealed a high specificity (100%) for LNM and a sensitivity (60%) comparable to the MSKCC nomogram (68%) and Partin tables (60%). For ECE, imaging revealed the highest sensitivity (94.3%) compared to the MSKCC nomogram (66%) and Partin tables (71.1%). For SVI, sensitivity and specificity of imaging and MSKCC nomogram were comparable (81.5% and 80% vs. 87.9% and 75%). The rate of concordance to the final pTN-stage was 60.3% for imaging, 52.1% for the MSKCC nomogram and 39.7% for Partin tables. Conclusion: In our analysis, preoperative one-stop shop 68 Ga-PSMA-11 PET/MRI performs at least equally for T- and N-stage prediction compared to nomograms in high-risk PC patients. Despite, an improved prediction of the full final stage and the yield of additional anatomical information, the use of 68 Ga-PSMA-11 PET/MRI warrants further prospective evaluation. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. [A comparative evaluation of modern antibacterial preparations in the treatment of a severe degree of periodontitis at a stage of exacerbation].

    PubMed

    Dmitrieva, L A; Tsarev, V N; Romanov, A E; Filatova, N A; Chernyshova, S B; Sechko, O N

    1998-01-01

    Sensitivities of peptostreptococci, streptococci, Actinomyces, bacteroid, and fusobacterial strains pathogenic for the periodontium to wide-spectrum penicillines, cephalosporines, lincomycin, macrolides, metronidasole, and nitasole are compared. New macrolide antibiotics rulide. Macropene, gramicidin C, levomycetin, and rifampicin are highly effective. Some narrow-spectrum drugs, e.g. augmentin, cephalexin, and vancomycin (towards actinomycetes) were highly effective, too.

  7. Microwave annealing effect for highly reliable biosensor: dual-gate ion-sensitive field-effect transistor using amorphous InGaZnO thin-film transistor.

    PubMed

    Lee, In-Kyu; Lee, Kwan Hyi; Lee, Seok; Cho, Won-Ju

    2014-12-24

    We used a microwave annealing process to fabricate a highly reliable biosensor using amorphous-InGaZnO (a-IGZO) thin-film transistors (TFTs), which usually experience threshold voltage instability. Compared with furnace-annealed a-IGZO TFTs, the microwave-annealed devices showed superior threshold voltage stability and performance, including a high field-effect mobility of 9.51 cm(2)/V·s, a low threshold voltage of 0.99 V, a good subthreshold slope of 135 mV/dec, and an outstanding on/off current ratio of 1.18 × 10(8). In conclusion, by using the microwave-annealed a-IGZO TFT as the transducer in an extended-gate ion-sensitive field-effect transistor biosensor, we developed a high-performance biosensor with excellent sensing properties in terms of pH sensitivity, reliability, and chemical stability.

  8. Enhanced response and sensitivity of self-corrugated graphene sensors with anisotropic charge distribution

    PubMed Central

    Yol Jeong, Seung; Jeong, Sooyeon; Won Lee, Sang; Tae Kim, Sung; Kim, Daeho; Jin Jeong, Hee; Tark Han, Joong; Baeg, Kang-Jun; Yang, Sunhye; Seok Jeong, Mun; Lee, Geon-Woong

    2015-01-01

    We introduce a high-performance molecular sensor using self-corrugated chemically modified graphene as a three dimensional (3D) structure that indicates anisotropic charge distribution. This is capable of room-temperature operation, and, in particular, exhibiting high sensitivity and reversible fast response with equilibrium region. The morphology consists of periodic, “cratered” arrays that can be formed by condensation and evaporation of graphene oxide (GO) solution on interdigitated electrodes. Subsequent hydrazine reduction, the corrugated edge area of the graphene layers have a high electric potential compared with flat graphene films. This local accumulation of electrons interacts with a large number of gas molecules. The sensitivity of 3D-graphene sensors significantly increases in the atmosphere of NO2 gas. The intriguing structures have several advantages for straightforward fabrication on patterned substrates, high-performance graphene sensors without post-annealing process. PMID:26053892

  9. Highly Sensitive and Selective Gas Sensor Using Hydrophilic and Hydrophobic Graphenes

    PubMed Central

    Some, Surajit; Xu, Yang; Kim, Youngmin; Yoon, Yeoheung; Qin, Hongyi; Kulkarni, Atul; Kim, Taesung; Lee, Hyoyoung

    2013-01-01

    New hydrophilic 2D graphene oxide (GO) nanosheets with various oxygen functional groups were employed to maintain high sensitivity in highly unfavorable environments (extremely high humidity, strong acidic or basic). Novel one-headed polymer optical fiber sensor arrays using hydrophilic GO and hydrophobic reduced graphene oxide (rGO) were carefully designed, leading to the selective sensing of volatile organic gases for the first time. The two physically different surfaces of GO and rGO could provide the sensing ability to distinguish between tetrahydrofuran (THF) and dichloromethane (MC), respectively, which is the most challenging issue in the area of gas sensors. The eco-friendly physical properties of GO allowed for faster sensing and higher sensitivity when compared to previous results for rGO even under extreme environments of over 90% humidity, making it the best choice for an environmentally friendly gas sensor. PMID:23736838

  10. Electron-density-sensitive Line Ratios of Fe xiii– xvi from Laboratory Sources Compared to CHIANTI

    DOE PAGES

    Weller, M. E.; Beiersdorfer, P.; Soukhanovskii, V. A.; ...

    2018-02-15

    We present electron-density-sensitive line ratios for Fe xiii– xvi measured in the spectral wavelength range of 200–440 Å and an electron density range of (1-4) × 10 13 cm -3. The results provide a test at the high-density limit of density-sensitive line ratios useful for astrophysical studies. The measurements were performed on the National Spherical Torus Experiment-Upgrade, where electron densities were measured independently by the laser Thomson scattering diagnostic. Spectra were collected with a flat-field grazing-incidence spectrometer, which provided a spectral resolution of up to 0.3 Å, i.e., high resolution across the broad wavelength range. The response of the instrumentmore » was relatively calibrated using spectroscopic techniques in order to improve accuracy. Lastly, the line ratios are compared to other laboratory sources and the latest version of CHIANTI (8.0.2), and an agreement within 30% is found.« less

  11. Detection of glucose-6-phosphate dehydrogenase deficiency in erythrocytes: a spectrophotometric assay and a fluorescent spot test compared with a cytochemical method.

    PubMed

    Wolf, B H; Weening, R S; Schutgens, R B; van Noorden, C J; Vogels, I M; Nagelkerke, N J

    1987-09-30

    The results of a quantitative spectrophotometric enzyme assay, a fluorescent spot test and a cytochemical assay for glucose-6-phosphate dehydrogenase deficiency were compared systematically. The high sensitivity of the spectrophotometric assay and the fluorescent spot test in the detection of severely deficient individuals was confirmed. For the detection of heterozygote females, however both tests were unreliable; the sensitivities of the fluorescent spot test and the spectrophotometric assay being 32% and 11% respectively. Specificities for both tests were high (99%). Introduction of the ratio of glucose-6-phosphate dehydrogenase and pyruvate kinase (G-6-PD/PK ratio) activities increased the sensitivity of the spectrophotometric assay to nearly 100%. It is concluded that the fluorescent spot test should be used for the diagnosis of G-6-PD deficiency in developing countries; whereas if spectrophotometric enzyme assays are available, the G-6-PD/PK ratio should always be performed. In cases where the ratio is less than 0.70, cytochemical analysis is indicated.

  12. Electron-density-sensitive Line Ratios of Fe xiii– xvi from Laboratory Sources Compared to CHIANTI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weller, M. E.; Beiersdorfer, P.; Soukhanovskii, V. A.

    We present electron-density-sensitive line ratios for Fe xiii– xvi measured in the spectral wavelength range of 200–440 Å and an electron density range of (1-4) × 10 13 cm -3. The results provide a test at the high-density limit of density-sensitive line ratios useful for astrophysical studies. The measurements were performed on the National Spherical Torus Experiment-Upgrade, where electron densities were measured independently by the laser Thomson scattering diagnostic. Spectra were collected with a flat-field grazing-incidence spectrometer, which provided a spectral resolution of up to 0.3 Å, i.e., high resolution across the broad wavelength range. The response of the instrumentmore » was relatively calibrated using spectroscopic techniques in order to improve accuracy. Lastly, the line ratios are compared to other laboratory sources and the latest version of CHIANTI (8.0.2), and an agreement within 30% is found.« less

  13. Portable evanescent wave fiber biosensor for highly sensitive detection of Shigella

    NASA Astrophysics Data System (ADS)

    Xiao, Rui; Rong, Zhen; Long, Feng; Liu, Qiqi

    2014-11-01

    A portable evanescent wave fiber biosensor was developed to achieve the rapid and highly sensitive detection of Shigella. In this study, a DNA probe was covalently immobilized onto fiber-optic biosensors that can hybridize with a fluorescently labeled complementary DNA. The sensitivity of detection for synthesized oligonucleotides can reach 10-10 M. The surface of the sensor can be regenerated with 0.5% sodium dodecyl sulfate solution (pH 1.9) for over 30 times without significant deterioration of performance. The total analysis time for a single sample, including the time for measurement and surface regeneration, was less than 6 min. We employed real-time polymerase chain reaction (PCR) and compared the results of both methods to investigate the actual Shigella DNA detection capability of the fiber-optic biosensor. The fiber-optic biosensor could detect as low as 102 colony-forming unit/mL Shigella. This finding was comparable with that by real-time PCR, which suggests that this method is a potential alternative to existing detection methods.

  14. Highly sensitive troponin T for risk stratification of acutely destabilized heart failure.

    PubMed

    Pascual-Figal, Domingo A; Casas, Teresa; Ordonez-Llanos, Jordi; Manzano-Fernández, Sergio; Bonaque, Juan C; Boronat, Miguel; Muñoz-Esparza, Carmen; Valdés, Mariano; Januzzi, James L

    2012-06-01

    A highly sensitive assay for troponin T (hsTnT) has been recently developed, which allows for the detection of even minor myocardial necrosis with high precision. It remains unexplored whether hsTnT provides incremental prognostic accuracy beyond conventional (c)TnT in patients with acutely decompensated heart failure (ADHF). A total of 202 consecutive patients admitted with ADHF and without criteria for acute myocardial infarction were studied. Troponin T was measured using the highly sensitive assay and compared with the conventional method. Patients were clinically followed up at a median of 406 days, with a primary outcome measure of all-cause mortality. The high-sensitive assay detected measurable TnT in 98% of patients vs 56% for cTnT; 81% had an hsTnT above the 99th percentile for a healthy reference population, and it reclassified 60% of those with undetectable cTnT. Both TnT methods predicted the risk of death in adjusted multivariable Cox regression analyses, without a superiority of hsTnT over cTnT in the entire population (area under the curve 0.67 vs 0.71, P = .2). Among patients with a cTnT below 0.03 ng/mL (the lowest cut-point with <10% imprecision; n = 134), solely hsTnT improved the prediction of death over clinical risk factors (relative integrated discrimination improvement +36%, P = .01) and hsTnT above 20 pg/mL identified a significant higher risk of death (hazard ratio 4.7, 95% CI 1.6-13.8, P = .005). Among patients with ADHF, myocardial necrosis (as detected with the hsTnT assay) was nearly ubiquitous. The highly sensitive assay for TnT provides comparable prognostic information to cTnT overall, but among those in whom the cTnT method was less precise or frankly negative, the hsTnT assay provided prognostic information. Copyright © 2012 Mosby, Inc. All rights reserved.

  15. Evaluation of immunity to varicella zoster virus with a novel double antigen sandwich enzyme-linked immunosorbent assay.

    PubMed

    Liu, Jian; Chen, Chunye; Zhu, Rui; Ye, Xiangzhong; Jia, Jizong; Yang, Lianwei; Wang, Yongmei; Wang, Wei; Ye, Jianghui; Li, Yimin; Zhu, Hua; Zhao, Qinjian; Zhang, Jun; Cheng, Tong; Xia, Ningshao

    2016-11-01

    Varicella is a highly contagious disease caused by primary infection of Varicella zoster virus (VZV). Varicella can be severe or even lethal in susceptible adults, immunocompromised patients and neonates. Determination of the status of immunity to VZV is recommended for these high-risk populations. Furthermore, measurement of population immunity to VZV can help in developing proper varicella vaccination programmes. VZV glycoprotein E (gE) is an antigen that has been demonstrated to be a highly accurate indicator of VZV-specific immunity. In this study, recombinant gE (rgE) was used to establish a double antigen sandwich enzyme-linked immunosorbent assay (ELISA). The established sandwich ELISA showed high specificity and sensitivity in the detection of human sera, and it could detect VZV-specific antibodies at a concentration of 11.25 m IU/mL with a detection linearity interval of 11.25 to 360 m IU/mL (R 2  = 0.9985). The double gE antigen sandwich ELISA showed a sensitivity of 95.08 % and specificity of 100 % compared to the fluorescent-antibody-to-membrane-antigen (FAMA) test, and it showed a sensitivity of 100 % and a specificity of 94.74 % compared to a commercial neutralizing antibody detection kit. Thus, the established double antigen sandwich ELISA can be used as a sensitive and specific quantitative method to evaluate immunity to VZV.

  16. High-Frequency Ultrasonic Imaging of the Anterior Segment Using an Annular Array Transducer

    PubMed Central

    Silverman, Ronald H.; Ketterling, Jeffrey A.; Coleman, D. Jackson

    2006-01-01

    Objective Very-high-frequency (>35 MHz) ultrasound (VHFU) allows imaging of anterior segment structures of the eye with a resolution of less than 40-μm. The low focal ratio of VHFU transducers, however, results in a depth-of-field (DOF) of less than 1-mm. Our aim was to develop a high-frequency annular array transducer for ocular imaging with improved DOF, sensitivity and resolution compared to conventional transducers. Design Experimental Study Participants Cadaver eyes, ex vivo cow eyes, in vivo rabbit eyes. Methods A spherically curved annular array ultrasound transducer was fabricated. The array consisted of five concentric rings of equal area, had an overall aperture of 6 mm and a geometric focus of 12 mm. The nominal center frequency of all array elements was 40 MHz. An experimental system was designed in which a single array element was pulsed and echo data recorded from all elements. By sequentially pulsing each element, echo data were acquired for all 25 transmit/receive annuli combinations. The echo data were then synthetically focused and composite images produced. Transducer operation was tested by scanning a test object consisting of a series of 25-μm diameter wires spaced at increasing range from the transducer. Imaging capabilities of the annular array were demonstrated in ex vivo bovine, in vivo rabbit and human cadaver eyes. Main Outcome Measures Depth of field, resolution and sensitivity. Results The wire scans verified the operation of the array and demonstrated a 6.0 mm DOF compared to the 1.0 mm DOF of a conventional single-element transducer of comparable frequency, aperture and focal length. B-mode images of ex vivo bovine, in vivo rabbit and cadaver eyes showed that while the single-element transducer had high sensitivity and resolution within 1–2 mm of its focus, the array with synthetic focusing maintained this quality over a 6 mm DOF. Conclusion An annular array for high-resolution ocular imaging has been demonstrated. This technology offers improved depth-of-field, sensitivity and lateral resolution compared to single-element fixed focus transducers currently used for VHFU imaging of the eye. PMID:17141314

  17. High-frequency ultrasonic imaging of the anterior segment using an annular array transducer.

    PubMed

    Silverman, Ronald H; Ketterling, Jeffrey A; Coleman, D Jackson

    2007-04-01

    Very high-frequency ultrasound (VHFU; >35 megahertz [MHz]) allows imaging of anterior segment structures of the eye with a resolution of less than 40 microm. The low focal ratio of VHFU transducers, however, results in a depth of field (DOF) of less than 1 mm. The aim was to develop a high-frequency annular array transducer for ocular imaging with improved DOF, sensitivity, and resolution compared with conventional transducers. Experimental study. Cadaver eyes, ex vivo cow eyes, in vivo rabbit eyes. A spherically curved annular array ultrasound transducer was fabricated. The array consisted of 5 concentric rings of equal area, had an overall aperture of 6 mm, and a geometric focus of 12 mm. The nominal center frequency of all array elements was 40 MHz. An experimental system was designed in which a single array element was pulsed and echo data were recorded from all elements. By sequentially pulsing each element, echo data were acquired for all 25 transmit-and-receive annuli combinations. The echo data then were focused synthetically and composite images were produced. Transducer operation was tested by scanning a test object consisting of a series of 25-microm diameter wires spaced at increasing range from the transducer. Imaging capabilities of the annular array were demonstrated in ex vivo bovine, in vivo rabbit, and human cadaver eyes. Depth of field, resolution, and sensitivity. The wire scans verified the operation of the array and demonstrated a 6.0-mm DOF, compared with the 1.0-mm DOF of a conventional single-element transducer of comparable frequency, aperture, and focal length. B-mode images of ex vivo bovine, in vivo rabbit, and cadaver eyes showed that although the single-element transducer had high sensitivity and resolution within 1 to 2 mm of its focus, the array with synthetic focusing maintained this quality over a 6-mm DOF. An annular array for high-resolution ocular imaging has been demonstrated. This technology offers improved DOF, sensitivity, and lateral resolution compared with single-element fixed focus transducers currently used for VHFU imaging of the eye.

  18. Rapid concentration and sensitive detection of hookworm ova from wastewater matrices using a real-time PCR method.

    PubMed

    Gyawali, P; Sidhu, J P S; Ahmed, W; Jagals, P; Toze, S

    2015-12-01

    The risk of human hookworm infections from land application of wastewater matrices could be high in regions with high hookworm prevalence. A rapid, sensitive and specific hookworm detection method from wastewater matrices is required in order to assess human health risks. Currently available methods used to identify hookworm ova to the species level are time consuming and lack accuracy. In this study, a real-time PCR method was developed for the rapid, sensitive and specific detection of canine hookworm (Ancylostoma caninum) ova from wastewater matrices. A. caninum was chosen because of its morphological similarity to the human hookworm (Ancylostoma duodenale and Necator americanus). The newly developed PCR method has high detection sensitivity with the ability to detect less than one A. caninum ova from 1 L of secondary treated wastewater at the mean threshold cycle (CT) values ranging from 30.1 to 34.3. The method is also able to detect four A. caninum ova from 1 L of raw wastewater and from ∼4 g of treated sludge with mean CT values ranging from 35.6 to 39.8 and 39.8 to 39.9, respectively. The better detection sensitivity obtained for secondary treated wastewater compared to raw wastewater and sludge samples could be attributed to sample turbidity. The proposed method appears to be rapid, sensitive and specific compared to traditional methods and has potential to aid in the public health risk assessment associated with land application of wastewater matrices. Furthermore, the method can be adapted to detect other helminth ova of interest from wastewater matrices. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  19. Computational simulation and aerodynamic sensitivity analysis of film-cooled turbines

    NASA Astrophysics Data System (ADS)

    Massa, Luca

    A computational tool is developed for the time accurate sensitivity analysis of the stage performance of hot gas, unsteady turbine components. An existing turbomachinery internal flow solver is adapted to the high temperature environment typical of the hot section of jet engines. A real gas model and film cooling capabilities are successfully incorporated in the software. The modifications to the existing algorithm are described; both the theoretical model and the numerical implementation are validated. The accuracy of the code in evaluating turbine stage performance is tested using a turbine geometry typical of the last stage of aeronautical jet engines. The results of the performance analysis show that the predictions differ from the experimental data by less than 3%. A reliable grid generator, applicable to the domain discretization of the internal flow field of axial flow turbine is developed. A sensitivity analysis capability is added to the flow solver, by rendering it able to accurately evaluate the derivatives of the time varying output functions. The complex Taylor's series expansion (CTSE) technique is reviewed. Two of them are used to demonstrate the accuracy and time dependency of the differentiation process. The results are compared with finite differences (FD) approximations. The CTSE is more accurate than the FD, but less efficient. A "black box" differentiation of the source code, resulting from the automated application of the CTSE, generates high fidelity sensitivity algorithms, but with low computational efficiency and high memory requirements. New formulations of the CTSE are proposed and applied. Selective differentiation of the method for solving the non-linear implicit residual equation leads to sensitivity algorithms with the same accuracy but improved run time. The time dependent sensitivity derivatives are computed in run times comparable to the ones required by the FD approach.

  20. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis

    PubMed Central

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation. PMID:29084241

  1. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    PubMed Central

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of 99% (95% CI 0.94-0.99). Taking into account that urine samples may be less sensitive than cervical samples, eight chlamydia studies that compared urine self-collected verses clinician-collected cervical samples had a sensitivity of 87% (95% CI 81-91) and high specificity of 99% (95% CI 0.98-1.00). For gonorrhea testing, self-collected urine samples compared to clinician-collected urethra samples in males produced a sensitivity of 92% (95% CI 83-97) and specificity of 99% (95% CI 0.98-1.00). Conclusion The sensitivity and specificity of vaginal self-collected swabs compared to swabs collected by clinicians supports the use of vaginal swab as the recommended specimen of choice in home-based screening for chlamydia and gonorrhea. Urine samples for gonorrhea collected by men had comparably high sensitivity and specificity, so could be recommended as they can be left at room temperature for several days, allowing for the possibility of mail-in home-based testing. In populations that may not go for testing at all, do not have the option of clinical testing, or who refuse a clinical examination, self-collected screening would be a good alternative. We recommend that guidelines on how to self-collect gonorrhea and chlamydia urine, vaginal, rectal and pharyngeal specimens be published. PMID:26168051

  2. Acute airway effects of airborne formaldehyde in sensitized and non-sensitized mice housed in a dry or humid environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Søren Thor, E-mail: stl@nrcwe.dk; Wolkoff, Peder, E-mail: pwo@nrcwe.dk; Hammer, Maria, E-mail: mha@nrcwe.dk

    We investigated the role of air humidity and allergic sensitization on the acute airway response to inhaled formaldehyde (FA) vapor. Mice were sensitized to the immunogen ovalbumin (OVA) by three intraperitoneal injections followed by two aerosol challenges, giving rise to allergic airway inflammation. Control mice were sham sensitized by saline injections and challenged by saline aerosols. Once sensitized, the mice were housed at high (85–89%) or low (< 10%) relative humidity, respectively for 48 h prior to a 60-min exposure to either 0.4, 1.8 or about 5 ppm FA. Before, during and after exposure, breathing parameters were monitored. These includedmore » the specific markers of nose and lung irritations as well as the expiratory flow rate, the latter being a marker of airflow limitation. The sensory irritation response in the upper airways was not affected by allergic inflammation or changes in humidity. At high relative humidity, the OVA-sensitized mice had a decreased expiratory airflow rate compared to the saline control mice after exposure to approximately 5 ppm FA. This is in accordance with the observations that asthmatics are more sensitive than non-asthmatics to higher concentrations of airway irritants including FA. In the dry environment, the opposite trend was seen; here, the saline control mice had a significantly decreased expiratory airflow rate compared to OVA-sensitized mice when exposed to 1.8 and 4 ppm FA. We speculate that increased mucus production in the OVA-sensitized mice has increased the “scrubber effect” in the nose, consequently protecting the conducting and lower airways. - Highlights: ► Role of air humidity and allergy on sensitivity to an airway irritant was studied. ► In the humid environment, allergy amplified the effects of formaldehyde. ► In the dry environment, allergy reduced the effect of formaldehyde. ► Neither allergy nor humidity changed the formaldehyde-induced nasal irritation.« less

  3. Highly Sensitive H2S Sensor Based on the Metal-Catalyzed SnO2 Nanocolumns Fabricated by Glancing Angle Deposition

    PubMed Central

    Yoo, Kwang Soo; Han, Soo Deok; Moon, Hi Gyu; Yoon, Seok-Jin; Kang, Chong-Yun

    2015-01-01

    As highly sensitive H2S gas sensors, Au- and Ag-catalyzed SnO2 thin films with morphology-controlled nanostructures were fabricated by using e-beam evaporation in combination with the glancing angle deposition (GAD) technique. After annealing at 500 °C for 40 h, the sensors showed a polycrystalline phase with a porous, tilted columnar nanostructure. The gas sensitivities (S = Rgas/Rair) of Au and Ag-catalyzed SnO2 sensors fabricated by the GAD process were 0.009 and 0.015, respectively, under 5 ppm H2S at 300 °C, and the 90% response time was approximately 5 s. These sensors showed excellent sensitivities compared with the SnO2 thin film sensors that were deposited normally (glancing angle = 0°, S = 0.48). PMID:26134105

  4. Patients with premenstrual syndrome have reduced sensitivity to midazolam compared to control subjects.

    PubMed

    Sundström, I; Nyberg, S; Bäckström, T

    1997-12-01

    Premenstrual syndrome (PMS) depends on gonadal hormones produced by the corpus luteum. Given the facilitory actions on GABAergic inhibitory neurotransmission exerted by certain progesterone metabolites, further studies on the GABAA receptor system in premenstrual syndrome are warranted. This study evaluated the benzodiazepine sensitivity in PMS patients and control subjects, using saccadic eye velocity (SEV) and visual analogue ratings of sedation as dependent measures. PMS patients displayed a significantly reduced SEV responsiveness to benzodiazepines compared to control subjects in the follicular phase, whereas there was no difference between groups in the luteal phase. In the luteal phase, the sedation response to benzodiazepines was significantly reduced in PMS patients compared to control subjects. There was also an influence of PMS symptom severity on these measures, as high-severity PMS patients displayed blunted SEV and sedation responses to benzodiazepines compared to low-severity patients. These results indicate that PMS patients have a reduced functional sensitivity at the GABAA/benzodiazepine receptor complex throughout the menstrual cycle.

  5. Associations of water balance and thermal sensitivity of toads with macroclimatic characteristics of geographical distribution.

    PubMed

    Titon, Braz; Gomes, Fernando Ribeiro

    2017-06-01

    Interspecific variation in patterns of geographical distribution of phylogenetically related species of amphibians might be related to physiological adaptation to different climatic conditions. In this way, a comparative study of resistance to evaporative water loss, rehydration rates and sensitivity of locomotor performance to variations on hydration level and temperature was performed for five species of Bufonidae toads (Rhinella granulosa, R. jimi, R. ornata, R. schneideri and R. icterica) inhabiting different Brazilian biomes. The hypotheses tested were that, when compared to species inhabiting mesic environments, species living at hot and dry areas would show: (1) greater resistance to evaporative water loss, (2) higher rates of water uptake, (3) lower sensitivity of locomotor performance to dehydration and (4) lower sensitivity of locomotor performance at higher temperatures and higher sensitivity of locomotor performance at lower temperatures. This comparative analysis showed relations between body mass and interspecific variation in rehydration rates and resistance to evaporative water loss in opposite directions. These results might represent a functional compensation associated with relatively lower absorption areas in larger toads and higher evaporative areas in smaller ones. Moreover, species from the semi-arid Caatinga showed locomotor performance less sensitive to dehydration but highly affected by lower temperatures, as well greater resistance to evaporative water loss, when compared to the other species from the mesic Atlantic Forest and the savannah-like area called Cerrado. These results suggest adaptation patterns to environmental conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. High road utilizers surveys compared to police data for road traffic crash hotspot localization in Rwanda and Sri Lanka.

    PubMed

    Staton, Catherine A; De Silva, Vijitha; Krebs, Elizabeth; Andrade, Luciano; Rulisa, Stephen; Mallawaarachchi, Badra Chandanie; Jin, Kezhi; RicardoVissoci, Joao; Østbye, Truls

    2016-01-20

    Road traffic crashes (RTCs) are a leading cause of death. In low and middle income countries (LMIC) data to conduct hotspot analyses and safety audits are usually incomplete, poor quality, and not computerized. Police data are often limited, but there are no alternative gold standards. This project evaluates high road utilizer surveys as an alternative to police data to identify RTC hotspots. Retrospective police RTC data was compared to prospective data from high road utilizer surveys regarding dangerous road locations. Spatial analysis using geographic information systems was used to map dangerous locations and identify RTC hotspots. We assessed agreement (Cohen's Kappa), sensitivity/specificity, and cost differences. In Rwanda police data identified 1866 RTC locations from 2589 records while surveys identified 1264 locations from 602 surveys. In Sri Lanka, police data identified 721 RTC locations from 752 records while survey data found 3000 locations from 300 surveys. There was high agreement (97 %, 83 %) and kappa (0.60, 0.60) for Rwanda and Sri Lanka respectively. Sensitivity and specificity are 92 % and 95 % for Rwanda and 74 % and 93 % for Sri Lanka. The cost per crash location identified was $2.88 for police and $2.75 for survey data in Rwanda and $2.75 for police and $1.21 for survey data in Sri Lanka. Surveys to locate RTC hotspots have high sensitivity and specificity compared to police data. Therefore, surveys can be a viable, inexpensive, and rapid alternative to the use of police data in LMIC.

  7. Disclosure of sensitive behaviors across self-administered survey modes: a meta-analysis.

    PubMed

    Gnambs, Timo; Kaspar, Kai

    2015-12-01

    In surveys, individuals tend to misreport behaviors that are in contrast to prevalent social norms or regulations. Several design features of the survey procedure have been suggested to counteract this problem; particularly, computerized surveys are supposed to elicit more truthful responding. This assumption was tested in a meta-analysis of survey experiments reporting 460 effect sizes (total N =125,672). Self-reported prevalence rates of several sensitive behaviors for which motivated misreporting has been frequently observed were compared across self-administered paper-and-pencil versus computerized surveys. The results revealed that computerized surveys led to significantly more reporting of socially undesirable behaviors than comparable surveys administered on paper. This effect was strongest for highly sensitive behaviors and surveys administered individually to respondents. Moderator analyses did not identify interviewer effects or benefits of audio-enhanced computer surveys. The meta-analysis highlighted the advantages of computerized survey modes for the assessment of sensitive topics.

  8. Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology

    NASA Astrophysics Data System (ADS)

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-08-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.

  9. Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology

    PubMed Central

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-01-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring. PMID:23982222

  10. Determination of chlorinated hydrocarbons in water using highly sensitive mid-infrared sensor technology.

    PubMed

    Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing

    2013-01-01

    Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.

  11. High-quality substrate for fluorescence enhancement using agarose-coated silica opal film.

    PubMed

    Xu, Ming; Li, Juan; Sun, Liguo; Zhao, Yuanjin; Xie, Zhuoying; Lv, Linli; Zhao, Xiangwei; Xiao, Pengfeng; Hu, Jing; Lv, Mei; Gu, Zhongze

    2010-08-01

    To improve the sensitivity of fluorescence detection in biochip, a new kind of substrates was developed by agarose coating on silica opal film. In this study, silica opal film was fabricated on glass substrate using the vertical deposition technique. It can provide stronger fluorescence signals and thus improve the detection sensitivity. After coating with agarose, the hybrid film could provide a 3D support for immobilizing sample. Comparing with agarose-coated glass substrate, the agarose-coated opal substrates could selectively enhance particular fluorescence signals with high sensitivity when the stop band of the silica opal film in the agarose-coated opal substrate overlapped the fluorescence emission wavelength. A DNA hybridization experiment demonstrated that fluorescence intensity of special type of agarose-coated opal substrates was about four times that of agarose-coated glass substrate. These results indicate that the optimized agarose-coated opal substrate can be used for improving the sensitivity of fluorescence detection with high quality and selectivity.

  12. Highly sensitive beam steering with plasmonic antenna

    PubMed Central

    Rui, Guanghao; Zhan, Qiwen

    2014-01-01

    In this work, we design and study a highly sensitive beam steering device that integrates a spiral plasmonic antenna with a subwavelength metallic waveguide. The short effective wavelength of the surface plasmon polaritons (SPPs) mode supported by the metallic waveguide is exploited to dramatically miniaturize the device and improve the sensitivity of the beam steering. Through introducing a tiny displacement of feed point with respect to the geometrical center of the spiral plasmonic antenna, the direction of the radiation can be steered at considerably high angles. Simulation results show that steering angles of 8°, 17° and 34° are obtainable for a displacement of 50 nm, 100 nm and 200 nm, respectively. Benefiting from the reduced device size and the shorter SPP wavelength, the beam steering sensitivity of the beam steering is improved by 10-fold compared with the case reported previously. This miniature plasmonic beam steering device may find many potential applications in quantum optical information processing and integrated photonic circuits. PMID:25091405

  13. New Perspectives on the Diagnosis of Allergy to Anisakis spp.

    PubMed

    Moneo, Ignacio; Carballeda-Sangiao, Noelia; González-Muñoz, Miguel

    2017-05-01

    To compare the prevalence of sensitization in different countries based on specific IgE values and to evaluate the use of isolated native or recombinant allergens for diagnosis. Isolated allergens help in the diagnosis of truly sensitized patients avoiding false positives due to cross-reactions. Their use is therefore highly recommended, especially when used as a combination of several relevant allergens. The use of purified allergens allows an accurate diagnosis and this has led to three important findings: (1) in addition to the digestive route of sensitization, occupational and non-digestive exposure seems to be clinically relevant. (2) The parasite appears as an important agent for chronic urticaria. And (3) in endemic countries, the amount of highly sensitized subjects in the general population could be as high as 7%. Adequate information to asymptomatic patients on fish consumption habits would avoid new contacts with parasite allergens and decrease their specific IgE levels and consequently the appearance of acute or chronic episodes induced by the parasite.

  14. GRIDSS: sensitive and specific genomic rearrangement detection using positional de Bruijn graph assembly

    PubMed Central

    Do, Hongdo; Molania, Ramyar

    2017-01-01

    The identification of genomic rearrangements with high sensitivity and specificity using massively parallel sequencing remains a major challenge, particularly in precision medicine and cancer research. Here, we describe a new method for detecting rearrangements, GRIDSS (Genome Rearrangement IDentification Software Suite). GRIDSS is a multithreaded structural variant (SV) caller that performs efficient genome-wide break-end assembly prior to variant calling using a novel positional de Bruijn graph-based assembler. By combining assembly, split read, and read pair evidence using a probabilistic scoring, GRIDSS achieves high sensitivity and specificity on simulated, cell line, and patient tumor data, recently winning SV subchallenge #5 of the ICGC-TCGA DREAM8.5 Somatic Mutation Calling Challenge. On human cell line data, GRIDSS halves the false discovery rate compared to other recent methods while matching or exceeding their sensitivity. GRIDSS identifies nontemplate sequence insertions, microhomologies, and large imperfect homologies, estimates a quality score for each breakpoint, stratifies calls into high or low confidence, and supports multisample analysis. PMID:29097403

  15. Increasing Electrochemiluminescence Intensity of a Wireless Electrode Array Chip by Thousands of Times Using a Diode for Sensitive Visual Detection by a Digital Camera.

    PubMed

    Qi, Liming; Xia, Yong; Qi, Wenjing; Gao, Wenyue; Wu, Fengxia; Xu, Guobao

    2016-01-19

    Both a wireless electrochemiluminescence (ECL) electrode microarray chip and the dramatic increase in ECL by embedding a diode in an electromagnetic receiver coil have been first reported. The newly designed device consists of a chip and a transmitter. The chip has an electromagnetic receiver coil, a mini-diode, and a gold electrode array. The mini-diode can rectify alternating current into direct current and thus enhance ECL intensities by 18 thousand times, enabling a sensitive visual detection using common cameras or smart phones as low cost detectors. The detection limit of hydrogen peroxide using a digital camera is comparable to that using photomultiplier tube (PMT)-based detectors. Coupled with a PMT-based detector, the device can detect luminol with higher sensitivity with linear ranges from 10 nM to 1 mM. Because of the advantages including high sensitivity, high throughput, low cost, high portability, and simplicity, it is promising in point of care testing, drug screening, and high throughput analysis.

  16. High Sensitivity, Wearable, Piezoresistive Pressure Sensors Based on Irregular Microhump Structures and Its Applications in Body Motion Sensing.

    PubMed

    Wang, Zongrong; Wang, Shan; Zeng, Jifang; Ren, Xiaochen; Chee, Adrian J Y; Yiu, Billy Y S; Chung, Wai Choi; Yang, Yong; Yu, Alfred C H; Roberts, Robert C; Tsang, Anderson C O; Chow, Kwok Wing; Chan, Paddy K L

    2016-07-01

    A pressure sensor based on irregular microhump patterns has been proposed and developed. The devices show high sensitivity and broad operating pressure regime while comparing with regular micropattern devices. Finite element analysis (FEA) is utilized to confirm the sensing mechanism and predict the performance of the pressure sensor based on the microhump structures. Silicon carbide sandpaper is employed as the mold to develop polydimethylsiloxane (PDMS) microhump patterns with various sizes. The active layer of the piezoresistive pressure sensor is developed by spin coating PSS on top of the patterned PDMS. The devices show an averaged sensitivity as high as 851 kPa(-1) , broad operating pressure range (20 kPa), low operating power (100 nW), and fast response speed (6.7 kHz). Owing to their flexible properties, the devices are applied to human body motion sensing and radial artery pulse. These flexible high sensitivity devices show great potential in the next generation of smart sensors for robotics, real-time health monitoring, and biomedical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Enhancing Breast Cancer Recurrence Algorithms Through Selective Use of Medical Record Data.

    PubMed

    Kroenke, Candyce H; Chubak, Jessica; Johnson, Lisa; Castillo, Adrienne; Weltzien, Erin; Caan, Bette J

    2016-03-01

    The utility of data-based algorithms in research has been questioned because of errors in identification of cancer recurrences. We adapted previously published breast cancer recurrence algorithms, selectively using medical record (MR) data to improve classification. We evaluated second breast cancer event (SBCE) and recurrence-specific algorithms previously published by Chubak and colleagues in 1535 women from the Life After Cancer Epidemiology (LACE) and 225 women from the Women's Health Initiative cohorts and compared classification statistics to published values. We also sought to improve classification with minimal MR examination. We selected pairs of algorithms-one with high sensitivity/high positive predictive value (PPV) and another with high specificity/high PPV-using MR information to resolve discrepancies between algorithms, properly classifying events based on review; we called this "triangulation." Finally, in LACE, we compared associations between breast cancer survival risk factors and recurrence using MR data, single Chubak algorithms, and triangulation. The SBCE algorithms performed well in identifying SBCE and recurrences. Recurrence-specific algorithms performed more poorly than published except for the high-specificity/high-PPV algorithm, which performed well. The triangulation method (sensitivity = 81.3%, specificity = 99.7%, PPV = 98.1%, NPV = 96.5%) improved recurrence classification over two single algorithms (sensitivity = 57.1%, specificity = 95.5%, PPV = 71.3%, NPV = 91.9%; and sensitivity = 74.6%, specificity = 97.3%, PPV = 84.7%, NPV = 95.1%), with 10.6% MR review. Triangulation performed well in survival risk factor analyses vs analyses using MR-identified recurrences. Use of multiple recurrence algorithms in administrative data, in combination with selective examination of MR data, may improve recurrence data quality and reduce research costs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Enhancing Breast Cancer Recurrence Algorithms Through Selective Use of Medical Record Data

    PubMed Central

    Chubak, Jessica; Johnson, Lisa; Castillo, Adrienne; Weltzien, Erin; Caan, Bette J.

    2016-01-01

    Abstract Background: The utility of data-based algorithms in research has been questioned because of errors in identification of cancer recurrences. We adapted previously published breast cancer recurrence algorithms, selectively using medical record (MR) data to improve classification. Methods: We evaluated second breast cancer event (SBCE) and recurrence-specific algorithms previously published by Chubak and colleagues in 1535 women from the Life After Cancer Epidemiology (LACE) and 225 women from the Women’s Health Initiative cohorts and compared classification statistics to published values. We also sought to improve classification with minimal MR examination. We selected pairs of algorithms—one with high sensitivity/high positive predictive value (PPV) and another with high specificity/high PPV—using MR information to resolve discrepancies between algorithms, properly classifying events based on review; we called this “triangulation.” Finally, in LACE, we compared associations between breast cancer survival risk factors and recurrence using MR data, single Chubak algorithms, and triangulation. Results: The SBCE algorithms performed well in identifying SBCE and recurrences. Recurrence-specific algorithms performed more poorly than published except for the high-specificity/high-PPV algorithm, which performed well. The triangulation method (sensitivity = 81.3%, specificity = 99.7%, PPV = 98.1%, NPV = 96.5%) improved recurrence classification over two single algorithms (sensitivity = 57.1%, specificity = 95.5%, PPV = 71.3%, NPV = 91.9%; and sensitivity = 74.6%, specificity = 97.3%, PPV = 84.7%, NPV = 95.1%), with 10.6% MR review. Triangulation performed well in survival risk factor analyses vs analyses using MR-identified recurrences. Conclusions: Use of multiple recurrence algorithms in administrative data, in combination with selective examination of MR data, may improve recurrence data quality and reduce research costs. PMID:26582243

  19. Comparative Sensitivity Analysis of Muscle Activation Dynamics

    PubMed Central

    Günther, Michael; Götz, Thomas

    2015-01-01

    We mathematically compared two models of mammalian striated muscle activation dynamics proposed by Hatze and Zajac. Both models are representative for a broad variety of biomechanical models formulated as ordinary differential equations (ODEs). These models incorporate parameters that directly represent known physiological properties. Other parameters have been introduced to reproduce empirical observations. We used sensitivity analysis to investigate the influence of model parameters on the ODE solutions. In addition, we expanded an existing approach to treating initial conditions as parameters and to calculating second-order sensitivities. Furthermore, we used a global sensitivity analysis approach to include finite ranges of parameter values. Hence, a theoretician striving for model reduction could use the method for identifying particularly low sensitivities to detect superfluous parameters. An experimenter could use it for identifying particularly high sensitivities to improve parameter estimation. Hatze's nonlinear model incorporates some parameters to which activation dynamics is clearly more sensitive than to any parameter in Zajac's linear model. Other than Zajac's model, Hatze's model can, however, reproduce measured shifts in optimal muscle length with varied muscle activity. Accordingly we extracted a specific parameter set for Hatze's model that combines best with a particular muscle force-length relation. PMID:26417379

  20. Optimizing spectral wave estimates with adjoint-based sensitivity maps

    NASA Astrophysics Data System (ADS)

    Orzech, Mark; Veeramony, Jay; Flampouris, Stylianos

    2014-04-01

    A discrete numerical adjoint has recently been developed for the stochastic wave model SWAN. In the present study, this adjoint code is used to construct spectral sensitivity maps for two nearshore domains. The maps display the correlations of spectral energy levels throughout the domain with the observed energy levels at a selected location or region of interest (LOI/ROI), providing a full spectrum of values at all locations in the domain. We investigate the effectiveness of sensitivity maps based on significant wave height ( H s ) in determining alternate offshore instrument deployment sites when a chosen nearshore location or region is inaccessible. Wave and bathymetry datasets are employed from one shallower, small-scale domain (Duck, NC) and one deeper, larger-scale domain (San Diego, CA). The effects of seasonal changes in wave climate, errors in bathymetry, and multiple assimilation points on sensitivity map shapes and model performance are investigated. Model accuracy is evaluated by comparing spectral statistics as well as with an RMS skill score, which estimates a mean model-data error across all spectral bins. Results indicate that data assimilation from identified high-sensitivity alternate locations consistently improves model performance at nearshore LOIs, while assimilation from low-sensitivity locations results in lesser or no improvement. Use of sub-sampled or alongshore-averaged bathymetry has a domain-specific effect on model performance when assimilating from a high-sensitivity alternate location. When multiple alternate assimilation locations are used from areas of lower sensitivity, model performance may be worse than with a single, high-sensitivity assimilation point.

  1. Systematic review: Comparison of Xpert MTB/RIF, LAMP and SAT methods for the diagnosis of pulmonary tuberculosis.

    PubMed

    Yan, Liping; Xiao, Heping; Zhang, Qing

    2016-01-01

    Technological advances in nucleic acid amplification have led to breakthroughs in the early detection of PTB compared to traditional sputum smear tests. The sensitivity and specificity of loop-mediated isothermal amplification (LAMP), simultaneous amplification testing (SAT), and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis were evaluated. A critical review of previous studies of LAMP, SAT, and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis that used laboratory culturing as the reference method was carried out together with a meta-analysis. In 25 previous studies, the pooled sensitivity and specificity of the diagnosis of tuberculosis were 93% and 94% for LAMP, 96% and 88% for SAT, and 89% and 98% for Xpert MTB/RIF. The I(2) values for the pooled data were >80%, indicating significant heterogeneity. In the smear-positive subgroup analysis of LAMP, the sensitivity increased from 93% to 98% (I(2) = 2.6%), and specificity was 68% (I(2) = 38.4%). In the HIV-infected subgroup analysis of Xpert MTB/RIF, the pooled sensitivity and specificity were 79% (I(2) = 72.9%) and 99% (I(2) = 64.4%). In the HIV-negative subgroup analysis for Xpert MTB/RIF, the pooled sensitivity and specificity were 72% (I(2) = 49.6%) and 99% (I(2) = 64.5%). LAMP, SAT and Xpert MTB/RIF had comparably high levels of sensitivity and specificity for the diagnosis of tuberculosis. The diagnostic sensitivity and specificity of three methods were similar, with LAMP being highly sensitive for the diagnosis of smear-positive PTB. The cost effectiveness of LAMP and SAT make them particularly suitable tests for diagnosing PTB in developing countries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    PubMed

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  3. Theoretical Design on a Series of Novel Bicyclic and Cage Nitramines as High Energy Density Compounds.

    PubMed

    Pan, Yong; Zhu, Weihua

    2017-11-30

    We designed four bicyclic nitramines and three cage nitramines by incorporating -N(NO 2 )-CH 2 -N(NO 2 )-, -N(NO 2 )-, and -O- linkages based on the HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazocane) framework. Then, their electronic structure, heats of formation, energetic properties, strain energy, thermal stability, and impact sensitivity were systematically studied using density functional theory (DFT). Compared to the parent compound HMX, all the title compounds have much higher density, better detonation properties, and better oxygen balance. Among them, four compounds have extraordinary high detonation properties (D > 9.70 km/s and P > 44.30 GPa). Moreover, most of the title compounds exhibit better thermal stability and lower impact sensitivity than CL-20 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane) or HNHAA (hexanitrohexaazaadamantane). Thus, all of the seven new nitramine compounds are promising candidates for high energy density compounds. In particular, five compounds exhibit a best combination of better oxygen balance, good thermal stability, excellent detonation properties superior to or comparable to CL-20 or HNHAA, and lower impact sensitivity than CL-20 or HNHAA. The results indicate that our unusual design strategy that constructing bicyclic or cage nitramines based on the HMX framework by incorporating the intramolecular linkages is very useful for developing novel energetic compounds with excellent detonation performance and low sensitivity.

  4. A high-throughput colorimetric assay for glucose detection based on glucose oxidase-catalyzed enlargement of gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Xiong, Yanmei; Zhang, Yuyan; Rong, Pengfei; Yang, Jie; Wang, Wei; Liu, Dingbin

    2015-09-01

    We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose.We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose. Electronic supplementary information (ESI) available: Experimental section and additional figures. See DOI: 10.1039/c5nr03758a

  5. MRI helps depict clinically undetectable risk factors in advanced stage retinoblastomas.

    PubMed

    Galluzzi, Paolo; Hadjistilianou, Theodora; Cerase, Alfonso; Toti, Paolo; Leonini, Sara; Bracco, Sandra; de Francesco, Sonia; Galimberti, Daniela; Balducci, Donatella; Piu, Pietro; Monti, Lucia; Bellini, Matteo; Caini, Mauro; Rossi, Alessandro

    2015-02-01

    This study compared high-resolution MRI with histology in advanced stage retinoblastomas in which ophthalmoscopy and ultrasonography did not give an exhaustive depiction of the tumour and/or its extension. MRI of orbits and head in 28 retinoblastoma patients (28 eyes) treated with primary enucleation were evaluated. Iris neoangiogenesis, infiltrations of optic nerve, choroid, anterior segment and sclera suspected at MR and histology were compared. Abnormal anterior segment enhancement (AASE) was also correlated with histologically proven infiltrations. Brain images were also evaluated. Significant values were obtained for: prelaminar optic nerve (ON) sensitivity (0.88), positive predictive value (PPV) (0.75) and negative predictive value (NPV) (0.71); post-laminar ON sensitivity (0.50), specificity (0.83), PPV (0.50) and NPV (0.83); overall choroid sensitivity (0.82), and massive choroid NPV (0.69); scleral specificity (1), and NPV (1). AASE correlated with iris neoangiogenesis in 14 out of 19 eyes, and showed significant values for: overall ON PPV (0.65), prelaminar ON sensitivity (0.65), and PPV (0.61), post-laminar ON NPV (0.64); overall choroid sensitivity (0.77), PPV (0.59) and NPV (0.73); scleral NPV (0.83); anterior segment sensitivity (1), and NPV (1). Odds ratios (OR) and accuracy were significant in scleral and prelaminar optic nerve infiltration. Brain examination was unremarkable in all cases. High-resolution MRI may add important findings to clinical evaluation of advanced stage retinoblastomas. © The Author(s) 2015 Reprints and permissions:]br]sagepub.co.uk/journalsPermissions.nav.

  6. Pain sensitivity and tactile spatial acuity are altered in healthy musicians as in chronic pain patients

    PubMed Central

    Zamorano, Anna M.; Riquelme, Inmaculada; Kleber, Boris; Altenmüller, Eckart; Hatem, Samar M.; Montoya, Pedro

    2015-01-01

    Extensive training of repetitive and highly skilled movements, as it occurs in professional classical musicians, may lead to changes in tactile sensitivity and corresponding cortical reorganization of somatosensory cortices. It is also known that professional musicians frequently experience musculoskeletal pain and pain-related symptoms during their careers. The present study aimed at understanding the complex interaction between chronic pain and music training with respect to somatosensory processing. For this purpose, tactile thresholds (mechanical detection, grating orientation, two-point discrimination) and subjective ratings to thermal and pressure pain stimuli were assessed in 17 professional musicians with chronic pain, 30 pain-free musicians, 20 non-musicians with chronic pain, and 18 pain-free non-musicians. We found that pain-free musicians displayed greater touch sensitivity (i.e., lower mechanical detection thresholds), lower tactile spatial acuity (i.e., higher grating orientation thresholds) and increased pain sensitivity to pressure and heat compared to pain-free non-musicians. Moreover, we also found that musicians and non-musicians with chronic pain presented lower tactile spatial acuity and increased pain sensitivity to pressure and heat compared to pain-free non-musicians. The significant increment of pain sensitivity together with decreased spatial discrimination in pain-free musicians and the similarity of results found in chronic pain patients, suggests that the extensive training of repetitive and highly skilled movements in classical musicians could be considered as a risk factor for developing chronic pain, probably due to use-dependent plastic changes elicited in somatosensory pathways. PMID:25610384

  7. Comparison of glaucoma diagnostic accuracy of macular ganglion cell complex thickness based on nonhighly myopic and highly myopic normative database

    PubMed Central

    Chen, Henry Shen-Lih; Liu, Chun-Hsiu; Lu, Da-Wen

    2016-01-01

    Background/Purpose: To evaluate and compare the diagnostic discriminative ability for detecting glaucoma in highly myopic eyes from a normative database of macular ganglion cell complex (mGCC) thickness based on nonhighly myopic and highly myopic normal eyes. Methods: Forty-nine eyes of 49 participants with high myopia (axial length ≥ 26.0 mm) were enrolled. Spectral-domain optical coherence tomography scans were done using RS-3000, and the mGCC thickness/significance maps within a 9-mm diameter circle were generated using built-in software. We compared the difference of sensitivity, specificity, and diagnostic accuracy between the nonhighly myopic database and the highly myopic database for differentiating the early glaucomatous eyes from the nonglaucomatous eyes. Results: This study enrolled 15 normal eyes and 34 eyes with glaucoma. The mean mGCC thickness of the glaucoma group was significantly less than that of the normal group (p < 0.001). Sensitivity was 96.3%, and the specificity was 50.0% when using the nonhighly myopic normative database. When the highly myopic normative database was used, the sensitivity was 88.9%, and the specificity was 90.0%. The false positive rate was significantly lower when using the highly myopic normative database (p < 0.05). Conclusion: The evaluations of glaucoma in eyes with high myopia using a nonhighly myopic normative database may lead to a frequent misdiagnosis. When evaluating glaucoma in high myopic eyes, the mGCC thickness determined by the long axial length high myopic normative database should be applied. PMID:29018704

  8. The Science and Design of the AGIS Observatory

    NASA Astrophysics Data System (ADS)

    Schroedter, Martin

    2010-02-01

    The AGIS observatory is a next-generation array of imaging atmospheric Cherenkov telescopes (IACTs) for gamma-ray astronomy between 100 GeV and 100 TeV. The AGIS observatory is the next logical step in high energy gamma-ray astronomy, offering improved angular resolution and sensitivity compared to FERMI, and overlapping the high energy end of FERMI's sensitivity band. The baseline AGIS observatory will employ an array of 36 Schwarzschild-Couder IACTs in combination with a highly pixelated (0.05^o diameter) camera. The instrument is designed to provide millicrab sensitivity over a wide (8^o diameter) field of view, allowing both deep studies of faint point sources as well as efficient mapping of the Galactic plane and extended sources. I will describe science drivers behind the AGIS observatory and the design and status of the project. )

  9. The Science and Design of the AGIS Observatory

    NASA Astrophysics Data System (ADS)

    Falcone, Abraham; Aliu, E.; Arlen, T.; Benbow, W.; Buckley, J.; Bugaev, S.; Byrum, K.; Ciupik, L.; Coppi, P.; Digel, S.; Drake, G.; Finley, J.; Fortson, L.; Franco, J.; Funk, S.; Guarino, V.; Gyuk, G.; Hanna, D.; Hiriart, D.; Humensky, B.; Holder, J.; Kaaret, P.; Karlsson, N.; Kieda, D.; Konopelko, A.; Krawczynski, H.; Krennrich, F.; LeBohec, S.; Maier, G.; Mukherjee, R.; Ong, R.; Otte, N.; Pareschi, G.; Pohl, M.; Quinn, J.; Ramsey, B.; Romani, R.; Rovero, A. C.; Schroedter, M.; Sinnis, C.; Slane, P.; Smith, A.; Swordy, S.; Tajima, H.; Vassiliev, V.; Wagner, R.; Wakely, S. P.; Weekes, T. C.; Weinstein, A.; Williams, D.

    2010-01-01

    The AGIS observatory is a next-generation array of imaging atmospheric Cherenkov telescopes (IACTs) for gamma-ray astronomy between 100GeV and 100 TeV. The AGIS observatory is the next logical step in high energy gamma-ray astronomy, offering improved angular resolution and sensitivity compared to FERMI, and overlapping the high energy end of FERMI's sensitivity band. The baseline AGIS observatory will employ an array of 36 Schwarzschild-Couder IACTs in combination with a highly pixelated (0.05 degree/pixel) camera. The instrument is designed to provide millicrab sensitivity over a wide (8 degree diameter) field of view, allowing both deep studies of faint point sources as well as efficient mapping of the Galactic plane and extended sources. This presentation will include a description of science drivers behind the AGIS observatory and the design and status of the project.

  10. Highly Sensitive Bulk Silicon Chemical Sensors with Sub-5 nm Thin Charge Inversion Layers.

    PubMed

    Fahad, Hossain M; Gupta, Niharika; Han, Rui; Desai, Sujay B; Javey, Ali

    2018-03-27

    There is an increasing demand for mass-producible, low-power gas sensors in a wide variety of industrial and consumer applications. Here, we report chemical-sensitive field-effect-transistors (CS-FETs) based on bulk silicon wafers, wherein an electrostatically confined sub-5 nm thin charge inversion layer is modulated by chemical exposure to achieve a high-sensitivity gas-sensing platform. Using hydrogen sensing as a "litmus" test, we demonstrate large sensor responses (>1000%) to 0.5% H 2 gas, with fast response (<60 s) and recovery times (<120 s) at room temperature and low power (<50 μW). On the basis of these performance metrics as well as standardized benchmarking, we show that bulk silicon CS-FETs offer similar or better sensing performance compared to emerging nanostructures semiconductors while providing a highly scalable and manufacturable platform.

  11. Rapid diagnostic tests for the home-based management of malaria, in a high-transmission area.

    PubMed

    Willcox, M L; Sanogo, F; Graz, B; Forster, M; Dakouo, F; Sidibe, O; Falquet, J; Giani, S; Diakite, C; Diallo, D

    2009-01-01

    Rapid diagnostic tests (RDT) are sometimes recommended to improve the home-based management of malaria. The accuracy of an RDT for the detection of clinical malaria and the presence of malarial parasites has recently been evaluated in a high-transmission area of southern Mali. During the same study, the cost-effectiveness of a 'test-and-treat' strategy for the home-based management of malaria (based on an artemisinin-combination therapy) was compared with that of a 'treat-all' strategy. Overall, 301 patients, of all ages, each of whom had been considered a presumptive case of uncomplicated malaria by a village healthworker, were checked with a commercial RDT (Paracheck-Pf). The sensitivity, specificity, and positive and negative predictive values of this test, compared with the results of microscopy and two different definitions of clinical malaria, were then determined. The RDT was found to be 82.9% sensitive (with a 95% confidence interval of 78.0%-87.1%) and 78.9% (63.9%-89.7%) specific compared with the detection of parasites by microscopy. In the detection of clinical malaria, it was 95.2% (91.3%-97.6%) sensitive and 57.4% (48.2%-66.2%) specific compared with a general practitioner's diagnosis of the disease, and 100.0% (94.5%-100.0%) sensitive but only 30.2% (24.8%-36.2%) specific when compared against the fulfillment of the World Health Organization's (2003) research criteria for uncomplicated malaria. Among children aged 0-5 years, the cost of the 'test-and-treat' strategy, per episode, was about twice that of the 'treat-all' (U.S.$1.0. v. U.S.$0.5). In older subjects, however, the two strategies were equally costly (approximately U.S.$2/episode). In conclusion, for children aged 0-5 years in a high-transmission area of sub-Saharan Africa, use of the RDT was not cost-effective compared with the presumptive treatment of malaria with an ACT. In older patients, use of the RDT did not reduce costs. The question remains whether either of the strategies investigated can be made affordable for the affected population.

  12. Different sensitization to storage mites depending on the co-exposure to house dust mites.

    PubMed

    Morales, María; Iraola, Victor; Leonor, José Ramón; Bartra, Joan; Rodríguez, Fernando; Boquete, Manuel; Huertas, Ángel Julio; Paniagua, María Josefa; Pinto, Helder; Carnés, Jerónimo

    2015-01-01

    Co-sensitization to house dust mites (HDMs) and storage mites (SMs) is very frequent, although the clinical relevance is not well established. To describe the pattern of sensitization and immunologic characterization of patients with positive skin prick test reactions to HDMs and SMs in 4 areas of Spain, selected according to high exposure to HDMs and variable exposure to SMs. One hundred sixty-nine individuals with positive skin prick test reactions to HDMs and SMs were included. Specific IgE levels to different mite species and to Der p 1, Der p 2, and Der p 10 were determined. Immunoblots to Dermatophagoides pteronyssinus, Lepidoglyphus destructor, and Tyrophagus putrescentiae extracts were carried out, and allergograms were obtained. Results of different areas were compared. A high rate of polysensitization to SMs was observed, although 12% of participants did not have specific IgE to any SM species. Sensitization to Dermatophagoides species, Der p 2, and L destructor were predominant, although significant differences were observed among areas depending on the grade of exposure to SMs. In areas with high exposure, the SM allergogram showed greater recognition of group 2 allergen. Sensitization patterns to SMs in patients sensitized to HDMs and SMs differ depending on the exposure to SMs. Sensitization, mainly to L destructor, seems to exist in areas with high exposure, possibly with group 2 allergens mainly involved. However, in areas with low SM populations, sensitizations observed by skin prick testing appear to be related to HDM exposure. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  13. An evaluation of the SD Bioline HIV/syphilis duo test.

    PubMed

    Holden, Jeffrey; Goheen, Joshua; Jett-Goheen, Mary; Barnes, Mathilda; Hsieh, Yu-Hsiang; Gaydos, Charlotte A

    2018-01-01

    Many health agencies now recommend routine HIV and syphilis testing for pregnant women and most-at-risk populations such as men who have sex with men. With the increased availability of highly sensitive, low cost rapid point-of-care tests, the ability to meet those recommendations has increased, granting wider access to quick and accurate diagnoses. Using blood specimens collected from a Baltimore City Health Department (BCHD) sexually transmitted infection clinic, we evaluated the SD Bioline HIV/Syphilis Duo, a rapid test that simultaneously detects antibodies to HIV and syphilis and has the potential to further benefit clinics and patients by reducing costs, testing complexity, and patient wait times. SD DUO HIV sensitivity and specificity, when compared to BCHD results, were 91.7 and 99.5%, respectively. SD DUO syphilis sensitivity and specificity, when compared to rapid plasma reagin, were 85.7 and 96.8%, respectively, and 69.7 and 99.7%, respectively, when compared to Treponema pallidum particle agglutination (TPPA). SD DUO syphilis sensitivity and specificity, when compared to a traditional screening algorithm, improved to 92.3 and 100%, respectively, and improved to 72.9 and 99.7%, respectively, when compared to a reverse screening algorithm. The HIV component of the SD DUO performed moderately well. However, results for the SD DUO syphilis component, when compared to TPPA, support the need for further testing and assessment.

  14. Docosapentaenoic acid and docosahexaenoic acid are positively associated with insulin sensitivity in rats fed high-fat and high-fructose diets.

    PubMed

    Huang, Jiung-Pang; Cheng, Mei-Ling; Hung, Cheng-Yu; Wang, Chao-Hung; Hsieh, Po-Shiuan; Shiao, Ming-Shi; Chen, Jan-Kan; Li, Dai-Er; Hung, Li-Man

    2017-10-01

    The aim of the present study was to compare insulin resistance and metabolic changes using a global lipidomic approach. Rats were fed a high-fat diet (HFD) or a high-fructose diet (HFrD) for 12 weeks to induce insulin resistance (IR) syndrome. After 12 weeks feeding, physiological and biochemical parameters were examined. Insulin sensitivity and plasma metabolites were evaluated using a euglycemic-hyperinsulinemic clamp and mass spectrometry, respectively. Pearson's correlation coefficient was used to investigate the strength of correlations. Rats on both diets developed IR syndrome, characterized by hypertension, hyperlipidemia, hyperinsulinemia, impaired fasting glucose, and IR. Compared with HFrD-fed rats, non-esterified fatty acids were lower and body weight and plasma insulin levels were markedly higher in HFD-fed rats. Adiposity and plasma leptin levels were increased in both groups. However, the size of adipocytes was greater in HFD- than HFrD-fed rats. Notably, the lipidomic heat map revealed metabolites exhibiting greater differences in HFD- and HFrD-fed rats compared with controls. Plasma adrenic acid levels were higher in HFD- than HFrD-fed rats. Nevertheless, linoleic and arachidonic acid levels decreased in HFrD-fed rats compared with controls. Plasma concentrations of docosapentaenoic acid (DPA) and docosahexaenoic acid (DHA) were significantly reduced after feeding of both diets, particularly the HFrD. There was a strong positive correlation between these two fatty acids and the insulin sensitivity index. The systemic lipidomic analysis indicated that a reduction in DHA and DPA was strongly correlated with IR in rats under long-term overnutrition. These results provide a potential therapeutic target for IR and metabolic syndrome. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  15. Epidermis Microstructure Inspired Graphene Pressure Sensor with Random Distributed Spinosum for High Sensitivity and Large Linearity.

    PubMed

    Pang, Yu; Zhang, Kunning; Yang, Zhen; Jiang, Song; Ju, Zhenyi; Li, Yuxing; Wang, Xuefeng; Wang, Danyang; Jian, Muqiang; Zhang, Yingying; Liang, Renrong; Tian, He; Yang, Yi; Ren, Tian-Ling

    2018-03-27

    Recently, wearable pressure sensors have attracted tremendous attention because of their potential applications in monitoring physiological signals for human healthcare. Sensitivity and linearity are the two most essential parameters for pressure sensors. Although various designed micro/nanostructure morphologies have been introduced, the trade-off between sensitivity and linearity has not been well balanced. Human skin, which contains force receptors in a reticular layer, has a high sensitivity even for large external stimuli. Herein, inspired by the skin epidermis with high-performance force sensing, we have proposed a special surface morphology with spinosum microstructure of random distribution via the combination of an abrasive paper template and reduced graphene oxide. The sensitivity of the graphene pressure sensor with random distribution spinosum (RDS) microstructure is as high as 25.1 kPa -1 in a wide linearity range of 0-2.6 kPa. Our pressure sensor exhibits superior comprehensive properties compared with previous surface-modified pressure sensors. According to simulation and mechanism analyses, the spinosum microstructure and random distribution contribute to the high sensitivity and large linearity range, respectively. In addition, the pressure sensor shows promising potential in detecting human physiological signals, such as heartbeat, respiration, phonation, and human motions of a pushup, arm bending, and walking. The wearable pressure sensor array was further used to detect gait states of supination, neutral, and pronation. The RDS microstructure provides an alternative strategy to improve the performance of pressure sensors and extend their potential applications in monitoring human activities.

  16. Mexico City air pollution adversely affects olfactory function and intranasal trigeminal sensitivity.

    PubMed

    Guarneros, Marco; Hummel, Thomas; Martínez-Gómez, Margaríta; Hudson, Robyn

    2009-11-01

    Surprisingly little is known about the effects of big-city air pollution on olfactory function and even less about its effects on the intranasal trigeminal system, which elicits sensations like burning, stinging, pungent, or fresh and contributes to the overall chemosensory experience. Using the Sniffin' Sticks olfactory test battery and an established test for intranasal trigeminal perception, we compared the olfactory performance and trigeminal sensitivity of residents of Mexico City, a region with high air pollution, with the performance of a control population from the Mexican state of Tlaxcala, a geographically comparable but less polluted region. We compared the ability of 30 young adults from each location to detect a rose-like odor (2-phenyl ethanol), to discriminate between different odorants, and to identify several other common odorants. The control subjects from Tlaxcala detected 2-phenyl ethanol at significantly lower concentrations than the Mexico City subjects, they could discriminate between odorants significantly better, and they performed significantly better in the test of trigeminal sensitivity. We conclude that Mexico City air pollution impairs olfactory function and intranasal trigeminal sensitivity, even in otherwise healthy young adults.

  17. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    PubMed Central

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would need to be supplemented with additional tests among populations where syphilis incidence is high to avoid missing early syphilis cases. PMID:24618681

  18. The accuracy of burn diagnosis codes in health administrative data: A validation study.

    PubMed

    Mason, Stephanie A; Nathens, Avery B; Byrne, James P; Fowler, Rob; Gonzalez, Alejandro; Karanicolas, Paul J; Moineddin, Rahim; Jeschke, Marc G

    2017-03-01

    Health administrative databases may provide rich sources of data for the study of outcomes following burn. We aimed to determine the accuracy of International Classification of Diseases diagnoses codes for burn in a population-based administrative database. Data from a regional burn center's clinical registry of patients admitted between 2006-2013 were linked to administrative databases. Burn total body surface area (TBSA), depth, mechanism, and inhalation injury were compared between the registry and administrative records. The sensitivity, specificity, and positive and negative predictive values were determined, and coding agreement was assessed with the kappa statistic. 1215 burn center patients were linked to administrative records. TBSA codes were highly sensitive and specific for ≥10 and ≥20% TBSA (89/93% sensitive and 95/97% specific), with excellent agreement (κ, 0.85/κ, 0.88). Codes were weakly sensitive (68%) in identifying ≥10% TBSA full-thickness burn, though highly specific (86%) with moderate agreement (κ, 0.46). Codes for inhalation injury had limited sensitivity (43%) but high specificity (99%) with moderate agreement (κ, 0.54). Burn mechanism had excellent coding agreement (κ, 0.84). Administrative data diagnosis codes accurately identify burn by burn size and mechanism, while identification of inhalation injury or full-thickness burns is less sensitive but highly specific. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  19. Claims-Based Definition of Death in Japanese Claims Database: Validity and Implications

    PubMed Central

    Ooba, Nobuhiro; Setoguchi, Soko; Ando, Takashi; Sato, Tsugumichi; Yamaguchi, Takuhiro; Mochizuki, Mayumi; Kubota, Kiyoshi

    2013-01-01

    Background For the pending National Claims Database in Japan, researchers will not have access to death information in the enrollment files. We developed and evaluated a claims-based definition of death. Methodology/Principal Findings We used healthcare claims and enrollment data between January 2005 and August 2009 for 195,193 beneficiaries aged 20 to 74 in 3 private health insurance unions. We developed claims-based definitions of death using discharge or disease status and Charlson comorbidity index (CCI). We calculated sensitivity, specificity and positive predictive values (PPVs) using the enrollment data as a gold standard in the overall population and subgroups divided by demographic and other factors. We also assessed bias and precision in two example studies where an outcome was death. The definition based on the combination of discharge/disease status and CCI provided moderate sensitivity (around 60%) and high specificity (99.99%) and high PPVs (94.8%). In most subgroups, sensitivity of the preferred definition was also around 60% but varied from 28 to 91%. In an example study comparing death rates between two anticancer drug classes, the claims-based definition provided valid and precise hazard ratios (HRs). In another example study comparing two classes of anti-depressants, the HR with the claims-based definition was biased and had lower precision than that with the gold standard definition. Conclusions/Significance The claims-based definitions of death developed in this study had high specificity and PPVs while sensitivity was around 60%. The definitions will be useful in future studies when used with attention to the possible fluctuation of sensitivity in some subpopulations. PMID:23741526

  20. Fasciculations in nerve and muscle disorders - A prospective study of muscle ultrasound compared to electromyography.

    PubMed

    Johansson, M T; Ellegaard, H R; Tankisi, H; Fuglsang-Frederiksen, A; Qerama, E

    2017-11-01

    We examined the clinical utility of muscle ultrasound (MUS) in detecting fasciculations in patients with nerve and muscle disorders (NMD) and investigated the impact on diagnostic sensitivity when combining electromyography (EMG) and MUS. We included 58 consecutive patients suspected to have NMD and 38 healthy subjects (HS). Patients and HS underwent MUS in 14 skeletal and two bulbar muscles and the video recordings of the MUS were anonymised. Only patients underwent EMG. The follow-up diagnoses were: 15 Amyotrophic lateral sclerosis (ALS), 15 polyneuropathy, 14 patients had other diagnoses (disease-control group) and 14 patients had no pathological findings. MUS detected more muscles with fasciculations among ALS patients compared to all other groups. In ALS patients, the dominating pattern of fasciculations was continuous (45%). More proximal muscles showed fasciculations among ALS patients compared to all other patient groups. MUS was more sensitive than EMG in detecting fasciculations (58% vs. 48%). When combining the two methods, the sensitivity in detecting fasciculations increased to 65%. Fasciculations in nine muscles could predict the ALS diagnosis with high sensitivity and specificity. MUS is a sensitive tool in detecting fasciculations in patients with NMD and performs well compared to EMG in diagnosing ALS. MUS may add valuable information in the clinic, especially in diagnosing ALS. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  1. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  2. Theoretical studies on effective metal-to-ligand charge transfer characteristics of novel ruthenium dyes for dye sensitized solar cells.

    PubMed

    Wang, Huei-Tang; Taufany, Fadlilatul; Nachimuthu, Santhanamoorthi; Jiang, Jyh-Chiang

    2014-05-01

    The development of ruthenium dye-sensitizers with highly effective metal-to-ligand charge transfer (MLCT) characteristics and narrowed transition energy gaps are essential for the new generation of dye-sensitized solar cells. Here, we designed a novel anchoring ligand by inserting the cyanovinyl-branches inside the anchoring ligands of selected highly efficient dye-sensitizers and studied their intrinsic optical properties using theoretical methods. Our calculated results show that the designed ruthenium dyes provide good performances as sensitizers compared to the selected efficient dyes, because of their red-shift in the UV-visible absorption spectra with an increase in the absorption intensity, smaller energy gaps and thereby enhancing MLCT transitions. We found that, the designed anchoring ligand acts as an efficient "electron-acceptor" which boosts electron-transfer from a -NCS ligand to this ligand via a Ru-bridge, thus providing a way to lower the transition energy gap and enhance the MLCT transitions.

  3. Age, sex and individual differences in punishment sensitivity: factors influencing the feedback-related negativity.

    PubMed

    Santesso, Diane L; Dzyundzyak, Angela; Segalowitz, Sidney J

    2011-11-01

    The anterior cingulate cortex (ACC) is central to evaluating performance outcomes and has been linked to individual differences in affective responses to feedback. We used electrophysiological source localization to examine the feedback-related negativity (FRN) and related ACC activity during a gambling task in relation to punishment and reward sensitivity among 16- to 17-year-old adolescents (n=20) and 18- to 29-year-old adults (n=30). The FRN was larger for monetary loss compared to win feedback and larger for high relative to low monetary value feedback, with no age differences in the FRN for win or loss feedback. Self-reported sensitivity to punishment accounted for unique variance (over sex and sensitivity to reward) in FRNs, with higher scores relating to larger FRNs and increased rostral ACC activity. These results support the ACC role in experiencing negative performance feedback, especially for individuals highly sensitive to punishment. Copyright © 2011 Society for Psychophysiological Research.

  4. Children Exposed to Intimate Partner Violence: Identifying Differential Effects of Family Environment on Children’s Trauma and Psychopathology Symptoms through Regression Mixture Models

    PubMed Central

    McDonald, Shelby Elaine; Shin, Sunny; Corona, Rosalie; Maternick, Anna; Graham-Bermann, Sandra A.; Ascione, Frank R.; Williams, James Herbert

    2016-01-01

    The majority of analytic approaches aimed at understanding the influence of environmental context on children’s socioemotional adjustment assume comparable effects of contextual risk and protective factors for all children. Using self-reported data from 289 maternal caregiver-child dyads, we examined the degree to which there are differential effects of severity of intimate partner violence (IPV) exposure, yearly household income, and number of children in the family on posttraumatic stress symptoms (PTS) and psychopathology symptoms (i.e., internalizing and externalizing problems) among school-age children between the ages of 7 to 12 years. A regression mixture model identified three latent classes that were primarily distinguished by differential effects of IPV exposure severity on PTS and psychopathology symptoms: (1) asymptomatic with low sensitivity to environmental factors (66% of children), (2) maladjusted with moderate sensitivity (24%), and (3) highly maladjusted with high sensitivity (10%). Children with mothers who had higher levels of education were more likely to be in the maladjusted with moderate sensitivity group than the asymptomatic with low sensitivity group. Latino children were less likely to be in both maladjusted groups compared to the asymptomatic group. Overall, the findings suggest differential effects of family environmental factors on PTS and psychopathology symptoms among children exposed to IPV. Implications for research and practice are discussed. PMID:27337691

  5. Children exposed to intimate partner violence: Identifying differential effects of family environment on children's trauma and psychopathology symptoms through regression mixture models.

    PubMed

    McDonald, Shelby Elaine; Shin, Sunny; Corona, Rosalie; Maternick, Anna; Graham-Bermann, Sandra A; Ascione, Frank R; Herbert Williams, James

    2016-08-01

    The majority of analytic approaches aimed at understanding the influence of environmental context on children's socioemotional adjustment assume comparable effects of contextual risk and protective factors for all children. Using self-reported data from 289 maternal caregiver-child dyads, we examined the degree to which there are differential effects of severity of intimate partner violence (IPV) exposure, yearly household income, and number of children in the family on posttraumatic stress symptoms (PTS) and psychopathology symptoms (i.e., internalizing and externalizing problems) among school-age children between the ages of 7-12 years. A regression mixture model identified three latent classes that were primarily distinguished by differential effects of IPV exposure severity on PTS and psychopathology symptoms: (1) asymptomatic with low sensitivity to environmental factors (66% of children), (2) maladjusted with moderate sensitivity (24%), and (3) highly maladjusted with high sensitivity (10%). Children with mothers who had higher levels of education were more likely to be in the maladjusted with moderate sensitivity group than the asymptomatic with low sensitivity group. Latino children were less likely to be in both maladjusted groups compared to the asymptomatic group. Overall, the findings suggest differential effects of family environmental factors on PTS and psychopathology symptoms among children exposed to IPV. Implications for research and practice are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Fracture behavior of the Fe-8Al alloy FAP-Y

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander, D.J.

    The tensile and impact properties of two heats of the reduced aluminum alloy FAP-Y have been measured and compared to the Fe{sub 3}Al alloy FA-129. The FAP-Y material has similar yield strengths up to 400{degrees}C, and much better ductility and impact properties, as compared to the FA-129. Despite excellent room-temperature ductility, the ductile-to-brittle transition temperature is still quite high, around 150{degrees}C. The material is found to be strain-rate sensitive, with a significant increase in the yield strength at strain rates of about 10{sup 3} s{sup {minus}1}. It is believed that this strain-rate sensitivity is responsible, at least in part, formore » the high ductile-to-brittle transition temperature.« less

  7. Drought sensitivity changes over the last century at the North American savanna-forest boundary

    NASA Astrophysics Data System (ADS)

    Heilman, K.; McLachlan, J. S.

    2017-12-01

    Future environmental changes can affect the sensitivity of tree growth to climate. Theses changes are of particular concern at biome boundaries where tree distribution could shift as a result of changes in both drought and drought sensitivity. One such region is the North American savanna-forest boundary, where increased CO2 and droughts could alter savanna and forest ecosystem distributions in two contrasting ways: 1). More severe droughts may increase drought sensitivity, favoring open savanna ecosystems or, 2). Increases in water use efficiency resulting from higher atmospheric CO2 may decrease drought sensitivity, promoting forest expansion. This study sought to understand whether the past 100 years of climate and CO2 changes have impacted regional tree growth-climate sensitivity. To test for these climate sensitivity changes, we measured the sensitivity of Quercus spp. radial growth to Palmer Drought Severity Index (PDSI). Tree growth sensitivity to climate can vary according to many factors, including: stand structure, available moisture, and tree age. To control for these factors, we sampled tree growth-climate responses at sites in both open and closed forests, and at both low and high annual precipitation. Within each site, we compared growth responses to climate between trees established under high CO2 conditions after 1950 (high CO2 young), and tree established before 1950 under low CO2 levels (low CO2 young). At most sites, low CO2 young have a higher drought sensitivity than higher CO2 young. These changes in the sensitivity to drought are consistent with CO2 enhancement of water use efficiency. Furthermore, these differences in drought sensitivity are higher at sites with high temperature and low precipitation, suggesting that the alleviation of drought is more likely in hot and dry regions. Thus, if CO2 enhancement is indeed occurring in these systems, lower growth sensitivity to drought in hot and dry regions could favor increased forest growth. If changes in drought sensitivity scale to ecosystem level, decreased drought sensitivity may have helped promote regional forest expansion.

  8. B cell repertoires in HLA-sensitized kidney transplant candidates undergoing desensitization therapy.

    PubMed

    Beausang, John F; Fan, H Christina; Sit, Rene; Hutchins, Maria U; Jirage, Kshama; Curtis, Rachael; Hutchins, Edward; Quake, Stephen R; Yabu, Julie M

    2017-01-13

    Kidney transplantation is the most effective treatment for end-stage renal disease. Sensitization refers to pre-existing antibodies against human leukocyte antigen (HLA) protein and remains a major barrier to successful transplantation. Despite implementation of desensitization strategies, many candidates fail to respond. Our objective was to determine whether measuring B cell repertoires could differentiate candidates that respond to desensitization therapy. We developed an assay based on high-throughput DNA sequencing of the variable domain of the heavy chain of immunoglobulin genes to measure changes in B cell repertoires in 19 highly HLA-sensitized kidney transplant candidates undergoing desensitization and 7 controls with low to moderate HLA sensitization levels. Responders to desensitization had a decrease of 5% points or greater in cumulated calculated panel reactive antibody (cPRA) levels, and non-responders had no decrease in cPRA. Dominant B cell clones were not observed in highly sensitized candidates, suggesting that the B cells responsible for sensitization are either not present in peripheral blood or present at comparable levels to other circulating B cells. Candidates that responded to desensitization therapy had pre-treatment repertoires composed of a larger fraction of class-switched (IgG and IgA) isotypes compared to non-responding candidates. After B cell depleting therapy, the proportion of switched isotypes increased and the mutation frequencies of the remaining non-switched isotypes (IgM and IgD) increased in both responders and non-responders, perhaps representing a shift in the repertoire towards memory B cells or plasmablasts. Conversely, after transplantation, non-switched isotypes with fewer mutations increased, suggesting a shift in the repertoire towards naïve B cells. Relative abundance of different B cell isotypes is strongly perturbed by desensitization therapy and transplantation, potentially reflecting changes in the relative abundance of memory and naïve B cell compartments. Candidates that responded to therapy experienced similar changes to those that did not respond. Further studies are required to understand differences between these two groups of highly sensitized kidney transplant candidates.

  9. Three-dimensional polarization algebra for all polarization sensitive optical systems.

    PubMed

    Li, Yahong; Fu, Yuegang; Liu, Zhiying; Zhou, Jianhong; Bryanston-Cross, P J; Li, Yan; He, Wenjun

    2018-05-28

    Using three-dimensional (3D) coherency vector (9 × 1), we develop a new 3D polarization algebra to calculate the polarization properties of all polarization sensitive optical systems, especially when the incident optical field is partially polarized or un-polarized. The polarization properties of a high numerical aperture (NA) microscope objective (NA = 1.25 immersed in oil) are analyzed based on the proposed 3D polarization algebra. Correspondingly, the polarization simulation of this high NA optical system is performed by the commercial software VirtualLAB Fusion. By comparing the theoretical calculations with polarization simulations, a perfect matching relation is obtained, which demonstrates that this 3D polarization algebra is valid to quantify the 3D polarization properties for all polarization sensitive optical systems.

  10. Enhancement of NH3 Gas Sensitivity at Room Temperature by Carbon Nanotube-Based Sensor Coated with Co Nanoparticles

    PubMed Central

    Nguyen, Lich Quang; Phan, Pho Quoc; Duong, Huyen Ngoc; Nguyen, Chien Duc; Nguyen, Lam Huu

    2013-01-01

    Multi-walled carbon nanotube (MWCNT) film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH3 gas sensing applications. The MWCNT-based sensor is sensitive to NH3 gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH3, compared with alcohol and LPG. PMID:23364198

  11. Chemiluminescent optical fiber immunosensor for the detection of anti-West Nile virus IgG.

    PubMed

    Herrmann, Sebastien; Leshem, Boaz; Landes, Shimi; Rager-Zisman, Bracha; Marks, Robert S

    2005-03-31

    An ELISA-based optical fiber methodology developed for the detection of anti-West Nile virus IgG antibodies in serum was compared to standard colorimetric and chemiluminescent ELISA based on microtiter plates. Colorimetric ELISA was the least sensitive, especially at high titer dilutions. The fiber-optic immunosensor based on the same ELISA immunological rationale was the most sensitive technique.

  12. A practical and highly sensitive C3N4-TYR fluorescent probe for convenient detection of dopamine

    NASA Astrophysics Data System (ADS)

    Li, Hao; Yang, Manman; Liu, Juan; Zhang, Yalin; Yang, Yanmei; Huang, Hui; Liu, Yang; Kang, Zhenhui

    2015-07-01

    The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules.The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr03316k

  13. Hantavirus pulmonary syndrome clinical findings: evaluating a surveillance case definition.

    PubMed

    Knust, Barbara; Macneil, Adam; Rollin, Pierre E

    2012-05-01

    Clinical cases of hantavirus pulmonary syndrome (HPS) can be challenging to differentiate from other acute respiratory diseases, which can lead to delays in diagnosis, treatment, and disease reporting. Rapid onset of severe disease occurs, at times before diagnostic test results are available. This study's objective was to examine the clinical characteristics of patients that would indicate HPS to aid in detection and reporting. Test results of blood samples from U.S. patients suspected of having HPS submitted to the Centers for Disease Control and Prevention from 1998-2010 were reviewed. Patient information collected by case report forms was compared between HPS-confirmed and test-negative patients. Diagnostic sensitivity, specificity, predictive values, and likelihood ratios were calculated for individual clinical findings and combinations of variables. Of 567 patients included, 36% were HPS-confirmed. Thrombocytopenia, chest x-rays with suggestive signs, and receiving supplemental oxygenation were highly sensitive (>95%), while elevated hematocrit was highly specific (83%) in detecting HPS. Combinations that maximized sensitivity required the presence of thrombocytopenia. Using a national sample of suspect patients, we found that thrombocytopenia was a highly sensitive indicator of HPS and should be included in surveillance definitions for suspected HPS. Using a sensitive suspect case definition to identify potential HPS patients that are confirmed by highly specific diagnostic testing will ensure accurate reporting of this disease.

  14. GRAPPA reconstructed wave-CAIPI MP-RAGE at 7 Tesla.

    PubMed

    Schwarz, Jolanda M; Pracht, Eberhard D; Brenner, Daniel; Reuter, Martin; Stöcker, Tony

    2018-04-16

    The aim of this project was to develop a GRAPPA-based reconstruction for wave-CAIPI data. Wave-CAIPI fully exploits the 3D coil sensitivity variations by combining corkscrew k-space trajectories with CAIPIRINHA sampling. It reduces artifacts and limits reconstruction induced spatially varying noise enhancement. The GRAPPA-based wave-CAIPI method is robust and does not depend on the accuracy of coil sensitivity estimations. We developed a GRAPPA-based, noniterative wave-CAIPI reconstruction algorithm utilizing multiple GRAPPA kernels. For data acquisition, we implemented a fast 3D magnetization-prepared rapid gradient-echo wave-CAIPI sequence tailored for ultra-high field application. The imaging results were evaluated by comparing the g-factor and the root mean square error to Cartesian CAIPIRINHA acquisitions. Additionally, to assess the performance of subcortical segmentations (calculated by FreeSurfer), the data were analyzed across five subjects. Sixteen-fold accelerated whole brain magnetization-prepared rapid gradient-echo data (1 mm isotropic resolution) were acquired in 40 seconds at 7T. A clear improvement in image quality compared to Cartesian CAIPIRINHA sampling was observed. For the chosen imaging protocol, the results of 16-fold accelerated wave-CAIPI acquisitions were comparable to results of 12-fold accelerated Cartesian CAIPIRINHA. In comparison to the originally proposed SENSitivity Encoding reconstruction of Wave-CAIPI data, the GRAPPA approach provided similar image quality. High-quality, wave-CAIPI magnetization-prepared rapid gradient-echo images can be reconstructed by means of a GRAPPA-based reconstruction algorithm. Even for high acceleration factors, the noniterative reconstruction is robust and does not require coil sensitivity estimations. By altering the aliasing pattern, ultra-fast whole-brain structural imaging becomes feasible. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Ag Nanoparticles-enhanced Fluorescence of Terbium-Deferasirox Complexes for the Highly Sensitive Determination of Deferasirox.

    PubMed

    Abolhasani, Jafar; Naderali, Roza; Hassanzadeh, Javad

    2016-01-01

    We describe the effect of different sized gold and silver nanoparticles on the terbium sensitized fluorescence of deferasirox. It is indicated that silver nanostructures, especially 18 nm Ag nanoparticles (AgNPs), have a remarkable amplifying effect compared to Au nanoparticles. Based on this observation, a highly sensitive and selective method was developed for the determination of deferasirox. Effects of various parameters like AgNPs and Tb(3+) concentration and pH of media were investigated. Under the optimal conditions, a calibration curve was plotted as the fluorescence intensities versus the concentration of deferasirox in the range of 0.1 to 200 nmol L(-1), and detection limit of 0.03 nmol L(-1) was obtained. The method has good linearity, recovery, reproducibility and sensitivity, and was satisfactorily applied for the determination of deferasirox in urine and pharmaceutical samples.

  16. Laser ablation surface-enhanced Raman microspectroscopy.

    PubMed

    Londero, Pablo S; Lombardi, John R; Leona, Marco

    2013-06-04

    Improved identification of trace organic compounds in complex matrixes is critical for a variety of fields such as material science, heritage science, and forensics. Surface-enhanced Raman scattering (SERS) is a vibrational spectroscopy technique that can attain single-molecule sensitivity and has been shown to complement mass spectrometry, but lacks widespread application without a robust method that utilizes the effect. We demonstrate a new, highly sensitive, and widely applicable approach to SERS analysis based on laser ablation in the presence of a tailored plasmonic substrate. We analyze several challenging compounds, including non-water-soluble pigments and dyed leather from an ancient Egyptian chariot, achieving sensitivity as high as 120 amol for a 1:1 signal-to-noise ratio and 5 μm spatial resolution. This represents orders of magnitude improvement in spatial resolution and sensitivity compared to those of other SERS approaches intended for widespread application, greatly increasing the applicability of SERS.

  17. Panel-based Genetic Diagnostic Testing for Inherited Eye Diseases is Highly Accurate and Reproducible and More Sensitive for Variant Detection Than Exome Sequencing

    PubMed Central

    Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.

    2015-01-01

    Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400

  18. Comparing Magnetic Resonance Imaging and High-Resolution Dynamic Ultrasonography for Diagnosis of Plantar Plate Pathology: A Case Series.

    PubMed

    Donegan, Ryan J; Stauffer, Anthony; Heaslet, Michael; Poliskie, Michael

    Plantar plate pathology has gained noticeable attention in recent years as an etiology of lesser metatarsophalangeal joint pain. The heightened clinical awareness has led to the need for more effective diagnostic imaging accuracy. Numerous reports have established the accuracy of both magnetic resonance imaging and ultrasonography for the diagnosis of plantar plate pathology. However, no conclusions have been made regarding which is the superior imaging modality. The present study reports a case series directly comparing high-resolution dynamic ultrasonography and magnetic resonance imaging. A multicenter retrospective comparison of magnetic resonance imaging versus high-resolution dynamic ultrasonography to evaluate plantar plate pathology with surgical confirmation was conducted. The sensitivity, specificity, and positive and negative predictive values for magnetic resonance imaging were 60%, 100%, 100%, and 33%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 66%. The sensitivity, specificity, and positive and negative predictive values for high-resolution dynamic ultrasound imaging were 100%, 100%, 100%, and 100%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 100%. The p value using Fisher's exact test for magnetic resonance imaging and high-resolution dynamic ultrasonography was p = .45, a difference that was not statistically significant. High-resolution dynamic ultrasonography had greater accuracy than magnetic resonance imaging in diagnosing lesser metatarsophalangeal joint plantar plate pathology, although the difference was not statistically significant. The present case series suggests that high-resolution dynamic ultrasonography can be considered an equally accurate imaging modality for plantar plate pathology at a potential cost savings compared with magnetic resonance imaging. Therefore, high-resolution dynamic ultrasonography warrants further investigation in a prospective study. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Vitamin D deficiency in childhood obesity is associated with high levels of circulating inflammatory mediators, and low insulin sensitivity.

    PubMed

    Reyman, M; Verrijn Stuart, A A; van Summeren, M; Rakhshandehroo, M; Nuboer, R; de Boer, F K; van den Ham, H J; Kalkhoven, E; Prakken, B; Schipper, H S

    2014-01-01

    Childhood obesity is accompanied by low-grade systemic inflammation, which contributes to the development of insulin resistance and cardiovascular complications later in life. As vitamin D exhibits profound immunomodulatory functions and vitamin D deficiency is highly prevalent in childhood obesity, we hypothesized that vitamin D deficiency in childhood obesity coincides with enhanced systemic inflammation and reduced insulin sensitivity. In a cross-sectional study of 64 obese and 32 healthy children aged 6-16 years, comprehensive profiling of 32 circulating inflammatory mediators was performed, together with assessment of 25-hydroxyvitamin D (25(OH)D) levels and measures for insulin sensitivity. Severe vitamin D insufficiency, which is further referred to as vitamin D deficiency, was defined as a 25(OH)D level ≤37.5 nmol l(-1), and was highly prevalent in obese (56%) versus healthy control children (16%). Throughout the study, 25(OH)D-deficient children were compared with the other children, including 25(OH)D insufficient (37.5-50 nmol l(-1)) and 25(OH)D sufficient children (≥50 nmol l(-1)). First, 25(OH)D-deficient obese children showed a lower insulin sensitivity than other obese children, as measured by a lower quantitative insulin sensitivity check index. Second, the association between 25(OH)D deficiency and insulin resistance in childhood obesity was confirmed with multiple regression analysis. Third, 25(OH)D-deficient obese children showed higher levels of the inflammatory mediators cathepsin S, chemerin and soluble vascular adhesion molecule (sVCAM), compared with the other obese children. Finally, hierarchical cluster analysis revealed an over-representation of 25(OH)D deficiency in obese children expressing inflammatory mediator clusters with high levels of cathepsin S, sVCAM and chemerin. 25(OH)D deficiency in childhood obesity was associated with enhanced systemic inflammation and reduced insulin sensitivity. The high cathepsin S and sVCAM levels may reflect activation of a pro-inflammatory, pro-diabetic and atherogenic pathway, which could be inhibited by vitamin D supplementation.

  20. Ability among adolescents for the metabolic syndrome to predict elevations in factors associated with type 2 diabetes and cardiovascular disease: data from the national health and nutrition examination survey 1999-2006.

    PubMed

    DeBoer, Mark D; Gurka, Matthew J

    2010-08-01

    The aim of this study was to compare currently proposed sets of pediatric metabolic syndrome criteria for the ability to predict elevations in "surrogate" factors that are associated with metabolic syndrome and with future cardiovascular disease and type 2 diabetes mellitus. These surrogate factors were fasting insulin, hemoglobin A1c (HbA1c), high-sensitivity C-reactive protein (hsCRP), and uric acid. Waist circumference (WC), blood pressure, triglycerides, high-density lipoprotein cholesterol (HDL-C), fasting glucose, fasting insulin, HbA1c, hsCRP, and uric acid measurements were obtained from 2,624 adolescent (12-18 years old) participants of the 1999-2006 National Health and Nutrition Examination Surveys. We identified children with metabolic syndrome as defined by six commonly used sets of pediatric metabolic syndrome criteria. We then defined elevations in the surrogate factors as values in the top 5% for the cohort and calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for each set of metabolic syndrome criteria and for each surrogate factor. Current pediatric metabolic syndrome criteria exhibited variable sensitivity and specificity for surrogate predictions. Metabolic syndrome criteria had the highest sensitivity for predicting fasting insulin (40-70%), followed by uric acid (31-54%), hsCRP (13-31%), and HbA1c (7-21%). The criteria of de Ferranti (which includes children with WC >75(th) percentile, compared to all other sets including children with WC >90(th) percentile) exhibited the highest sensitivity for predicting each of the surrogates, with only modest decrease in specificity compared to the other sets of criteria. However, the de Ferranti criteria also exhibited the lowest PPV values. Conversely, the pediatric International Diabetes Federation criteria exhibited the lowest sensitivity and the highest specificity. Pediatric metabolic syndrome criteria exhibit moderate sensitivity for detecting elevations in surrogate factors associated with metabolic syndrome and with risk for future disease. Inclusion of children with more modestly elevated WC improved sensitivity.

  1. Frequency non-degenerate phase-sensitive optical parametric amplification based on four-wave-mixing in width-modulated silicon waveguides.

    PubMed

    Wang, Zhaolu; Liu, Hongjun; Sun, Qibing; Huang, Nan; Li, Xuefeng

    2014-12-15

    A width-modulated silicon waveguide is proposed to realize non-degenerate phase sensitive optical parametric amplification. It is found that the relative phase at the input of the phase sensitive amplifier (PSA) θIn-PSA can be tuned by tailoring the width and length of the second segment of the width-modulated silicon waveguide, which will influence the gain in the parametric amplification process. The maximum gain of PSA is larger by 9 dB compared with the phase insensitive amplifier (PIA) gain, and the gain bandwidth of PSA is larger by 35 nm compared with the gain bandwidth of PIA. Our on-chip PSA can find important potential applications in highly integrated optical circuits for optical chip-to-chip communication and computers.

  2. Case-Deletion Diagnostics for Maximum Likelihood Multipoint Quantitative Trait Locus Linkage Analysis

    PubMed Central

    Mendoza, Maria C.B.; Burns, Trudy L.; Jones, Michael P.

    2009-01-01

    Objectives Case-deletion diagnostic methods are tools that allow identification of influential observations that may affect parameter estimates and model fitting conclusions. The goal of this paper was to develop two case-deletion diagnostics, the exact case deletion (ECD) and the empirical influence function (EIF), for detecting outliers that can affect results of sib-pair maximum likelihood quantitative trait locus (QTL) linkage analysis. Methods Subroutines to compute the ECD and EIF were incorporated into the maximum likelihood QTL variance estimation components of the linkage analysis program MAPMAKER/SIBS. Performance of the diagnostics was compared in simulation studies that evaluated the proportion of outliers correctly identified (sensitivity), and the proportion of non-outliers correctly identified (specificity). Results Simulations involving nuclear family data sets with one outlier showed EIF sensitivities approximated ECD sensitivities well for outlier-affected parameters. Sensitivities were high, indicating the outlier was identified a high proportion of the time. Simulations also showed the enormous computational time advantage of the EIF. Diagnostics applied to body mass index in nuclear families detected observations influential on the lod score and model parameter estimates. Conclusions The EIF is a practical diagnostic tool that has the advantages of high sensitivity and quick computation. PMID:19172086

  3. The Abbott RealTime High Risk HPV test is a clinically validated human papillomavirus assay for triage in the referral population and use in primary cervical cancer screening in women 30 years and older: a review of validation studies.

    PubMed

    Poljak, Mario; Oštrbenk, Anja

    2013-01-01

    Human papillomavirus (HPV) testing has become an essential part of current clinical practice in the management of cervical cancer and precancerous lesions. We reviewed the most important validation studies of a next-generation real-time polymerase chain reaction-based assay, the RealTime High Risk HPV test (RealTime)(Abbott Molecular, Des Plaines, IL, USA), for triage in referral population settings and for use in primary cervical cancer screening in women 30 years and older published in peer-reviewed journals from 2009 to 2013. RealTime is designed to detect 14 high-risk HPV genotypes with concurrent distinction of HPV-16 and HPV-18 from 12 other HPV genotypes. The test was launched on the European market in January 2009 and is currently used in many laboratories worldwide for routine detection of HPV. We concisely reviewed validation studies of a next-generation real-time polymerase chain reaction (PCR)-based assay: the Abbott RealTime High Risk HPV test. Eight validation studies of RealTime in referral settings showed its consistently high absolute clinical sensitivity for both CIN2+ (range 88.3-100%) and CIN3+ (range 93.0-100%), as well as comparative clinical sensitivity relative to the currently most widely used HPV test: the Qiagen/Digene Hybrid Capture 2 HPV DNA Test (HC2). Due to the significantly different composition of the referral populations, RealTime absolute clinical specificity for CIN2+ and CIN3+ varied greatly across studies, but was comparable relative to HC2. Four validation studies of RealTime performance in cervical cancer screening settings showed its consistently high absolute clinical sensitivity for both CIN2+ and CIN3+, as well as comparative clinical sensitivity and specificity relative to HC2 and GP5+/6+ PCR. RealTime has been extensively evaluated in the last 4 years. RealTime can be considered clinically validated for triage in referral population settings and for use in primary cervical cancer screening in women 30 years and older.

  4. Flexible scintillator autoradiography for tumor margin inspection using 18F-FDG

    NASA Astrophysics Data System (ADS)

    Vyas, K. N.; Grootendorst, M.; Mertzanidou, T.; Macholl, S.; Stoyanov, D.; Arridge, S. R.; Tuch, D. S.

    2018-03-01

    Autoradiography potentially offers high molecular sensitivity and spatial resolution for tumor margin estimation. However, conventional autoradiography requires sectioning the sample which is destructive and labor-intensive. Here we describe a novel autoradiography technique that uses a flexible ultra-thin scintillator which conforms to the sample surface. Imaging with the flexible scintillator enables direct, high-resolution and high-sensitivity imaging of beta particle emissions from targeted radiotracers. The technique has the potential to identify positive tumor margins in fresh unsectioned samples during surgery, eliminating the processing time demands of conventional autoradiography. We demonstrate the feasibility of the flexible autoradiography approach to directly image the beta emissions from radiopharmaceuticals using lab experiments and GEANT-4 simulations to determine i) the specificity for 18F compared to 99mTc-labeled tracers ii) the sensitivity to detect signal from various depths within the tissue. We found that an image resolution of 1.5 mm was achievable with a scattering background and we estimate a minimum detectable activity concentration of 0.9 kBq/ml for 18F. We show that the flexible autoradiography approach has high potential as a technique for molecular imaging of tumor margins using 18F-FDG in a tumor xenograft mouse model imaged with a radiation-shielded EMCCD camera. Due to the advantage of conforming to the specimen, the flexible scintillator showed significantly better image quality in terms of tumor signal to whole-body background noise compared to rigid and optimally thick CaF2:Eu and BC400. The sensitivity of the technique means it is suitable for clinical translation.

  5. Sensitivity enhancement by chromatographic peak concentration with ultra-high performance liquid chromatography-nuclear magnetic resonance spectroscopy for minor impurity analysis.

    PubMed

    Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko

    2017-07-28

    High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. High-resolution endoscopy plus chromoendoscopy or narrow-band imaging in Barrett's esophagus: a prospective randomized crossover study.

    PubMed

    Kara, M A; Peters, F P; Rosmolen, W D; Krishnadath, K K; ten Kate, F J; Fockens, P; Bergman, J J G H

    2005-10-01

    High-resolution endoscopy (HRE) may improve the detection of early neoplasia in Barrett's esophagus. Indigo carmine chromoendoscopy (ICC) and narrow-band imaging (NBI) may be useful techniques to complement HRE. The aim of this study was to compare HRE-ICC with HRE-NBI for the detection of high-grade dysplasia or early cancer (HGD/EC) in patients with Barrett's esophagus. Twenty-eight patients with Barrett's esophagus underwent HRE-ICC and HRE-NBI (separated by 6 - 8 weeks) in a randomized sequence. The two procedures were performed by two different endoscopists, who were blinded to the findings of the other examination. Targeted biopsies were taken from all detected lesions, followed by four-quadrant biopsies at 2-cm intervals. Biopsy evaluation was supervised by a single expert pathologist, who was blinded to the imaging technique used. Fourteen patients were diagnosed with HGD/EC. The sensitivity for HGD/EC was 93 % and 86 % for HRE-ICC and HRE-NBI, respectively. Targeted biopsies had a sensitivity of 79 % with HRE alone. HGD was diagnosed from random biopsies alone in only one patient. ICC and NBI detected a limited number of additional lesions occult to HRE, but these lesions did not alter the sensitivity for identifying patients with HGD/EC. In most patients with high-grade dysplasia or early cancer in Barrett's esophagus, subtle lesions can be identified with high-resolution endoscopy. Indigo carmine chromoendoscopy and narrow-band imaging are comparable as adjuncts to high-resolution endoscopy.

  7. A Comparative Study Between Smartphone-Based Microscopy and Conventional Light Microscopy in 1021 Dermatopathology Specimens.

    PubMed

    Jahan-Tigh, Richard R; Chinn, Garrett M; Rapini, Ronald P

    2016-01-01

    The incorporation of high-resolution cameras into smartphones has allowed for a variety of medical applications including the use of lens attachments that provide telescopic, macroscopic, and dermatoscopic data, but the feasibility and performance characteristics of such a platform for use in dermatopathology have not been described. To determine the diagnostic performance of a smartphone microscope compared to traditional light microscopy in dermatopathology specimens. A simple smartphone microscope constructed with a 3-mm ball lens was used to prospectively evaluate 1021 consecutive dermatopathology cases in a blinded fashion. Referred, consecutive specimens from the community were evaluated at a single university hospital. The performance characteristics of the smartphone platform were calculated by using conventional light microscopy as the gold standard. The sensitivity and specificity for the diagnosis of melanoma, nonmelanoma skin cancers, and other miscellaneous conditions by the phone microscopy platform, as compared with traditional light microscopy, were calculated. For basal cell carcinoma (n = 136), the sensitivity and specificity of smartphone microscopy were 95.6% and 98.1%, respectively. The sensitivity and specificity for squamous cell carcinoma (n = 94) were 89.4% and 97.3%, respectively. The lowest sensitivity was found in melanoma (n = 15) at 60%, although the specificity was high at 99.1%. The accuracy of diagnosis of inflammatory conditions and other neoplasms was variable. Mobile phone-based microscopy has excellent performance characteristics for the inexpensive diagnosis of nonmelanoma skin cancers in a setting where a traditional microscope is not available.

  8. Remembering rejection: specificity and linguistic styles of autobiographical memories in borderline personality disorder and depression.

    PubMed

    Rosenbach, Charlotte; Renneberg, Babette

    2015-03-01

    High levels of rejection sensitivity are assumed to be the result of early and prolonged experiences of rejection. Aim of this study was to investigate autobiographical memories of rejection in clinical samples high in rejection sensitivity (Borderline Personality Disorder, BPD, and Major Depressive Disorder, MDD) and to identify group differences in the quality of the memories. Memories of rejection were retrieved using an adapted version of the Autobiographical Memory Test (AMT; five positive cue words, five cue words referring to rejection). Specificity of memories and linguistic word usage was analyzed in 30 patients with BPD, 27 patients with MDD and 30 healthy controls. Patients with BPD retrieved less specific memories compared to the healthy control group, whereas patients with MDD did not differ from controls in this regard. The group difference was no longer significant when controlling for rejection sensitivity. Linguistic analysis indicated that compared to both other groups, patients with BPD showed a higher self-focus, used more anger-related words, referred more frequently to social environments, and rated memories of rejection as more relevant for today's life. Clinical symptoms were not assessed in the control group. Moreover, the written form of the AMT might reduce the total number of specific memories. The level of rejection sensitivity influenced the specificity of the retrieved memories. Analysis of linguistic styles revealed specific linguistic patterns in BPD compared to non-clinical as well as depressed participants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Evaluation of chromogenic media and seminested PCR in the identification of Candida species

    PubMed Central

    Daef, Enas; Moharram, Ahmed; Eldin, Salwa Seif; Elsherbiny, Nahla; Mohammed, Mona

    2014-01-01

    Identification of Candida cultured from various clinical specimens to the species level is increasingly necessary for clinical laboratories. Although sn PCR identifies the species within hours but its cost-effectiveness is to be considered. So there is always a need for media which help in the isolation and identification at the species level. The study aimed to evaluate the performance of different chromogenic media and to compare the effectiveness of the traditional phenotypic methods vs. seminested polymerase chain reaction (sn PCR) for identification of Candida species. One hundred and twenty seven Candida strains isolated from various clinical specimens were identified by conventional methods, four different chromogenic media and sn PCR. HiCrome Candida Differential and CHROMagar Candida media showed comparably high sensitivities and specificities in the identification of C. albicans, C. tropicalis, C. glabrata and C. krusei. CHROMagar Candida had an extra advantage of identifying all C. parapsilosis isolates. CHROMagar-Pal’s medium identified C. albicans, C. tropicalis and C. krusei with high sensitivities and specificities, but couldn’t identify C. glabrata or C. parapsilosis. It was the only medium that identified C. dubliniensis with a sensitivity and specificity of 100%. Biggy agar showed the least sensitivities and specificities. The overall concordance of the snPCR compared to the conventional tests including CHROMAgar Candida in the identification of Candida species was 97.5%. The use of CHROMAgar Candida medium is an easy and accurate method for presumptive identification of the most commonly encountered Candida spp. PMID:24948942

  10. Switching from high-fat to low-fat diet normalizes glucose metabolism and improves glucose-stimulated insulin secretion and insulin sensitivity but not body weight in C57BL/6J mice.

    PubMed

    Agardh, Carl-David; Ahrén, Bo

    2012-03-01

    Environmental factors such as a high-fat diet contribute to type 2 diabetes and obesity. This study examined glycemia, insulin sensitivity, and β-cell function after switching from a high-fat diet to a low-fat diet in mice. C57BL/6J mice were fed a high-fat diet or low-fat diet for 18 months, after which mice on the high-fat diet either maintained this diet or switched to a low-fat diet for 4 weeks. Body weight and glucose and insulin responses to intraperitoneal glucose were determined. Insulin secretion (insulinogenic index: the 10-minute insulin response divided by the 10-minute glucose level) and insulin sensitivity (1 divided by basal insulin) were determined. After 18 months on a high-fat diet, mice had glucose intolerance, marked hyperinsulinemia, and increased body weight compared to mice on a low-fat diet (P < 0.001). Switching from a high-fat diet to low-fat diet normalized glucose tolerance, reduced but not normalized body weight (P < 0.001), increased insulin secretion (248 ± 39 vs 141 ± 46 pmol/mmol; P = 0.028) and improved but not normalized insulin sensitivity (3.2 ± 0.1 vs 1.0 ± 0.1 [pmol/L]; P = 0.012). Switching from a high-fat diet to low-fat diet normalizes glucose tolerance and improves but not normalizes insulin secretion and insulin sensitivity. These effects are more pronounced than the reduced body weight.

  11. Comparative diagnostic evaluation of OMP31 gene based TaqMan® real-time PCR assay with visual LAMP assay and indirect ELISA for caprine brucellosis.

    PubMed

    Saini, Suman; Gupta, V K; Gururaj, K; Singh, D D; Pawaiya, R V S; Gangwar, N K; Mishra, A K; Dwivedi, Deepak; Andani, Dimple; Kumar, Ashok; Goswami, T K

    2017-08-01

    Brucellosis is one of the leading causes of abortion in domestic animals that imposes costs on both economy and society. The disease is highly zoonotic and poses risk to animal handlers due to its zoonotic nature. It causes stillbirth, loss of kids and abortion in last term of pregnancy. Reproductive damage includes infertility in does and orchitis and epididymitis in breeding bucks, which result in high financial losses to farmers and the agriculture industry as a whole. It requires highly sensitive and specific assays to diagnose the disease at field level. In the current study, a visual loop-mediated isothermal amplification (LAMP) assay and the TaqMan® real-time PCR were developed with high sensitivity and specificity. For the TaqMan® probe, real-time PCR primers were developed using Omp31 gene as target and primers were designed using discontiguous conserved sequences of Omp31 gene. The Omp31 probes were designed by attaching 6-FAM reporter dye at the 5' end and BHQ-1 quencher at the 3' end. Published primers were used for visual LAMP assay targeting the Omp25 gene. Sensitivity of the standardized visual LAMP assay and TaqMan® real-time PCR assay was determined by serial dilution of positive Brucella melitensis DNA (10 2 to 10 -4  ng) obtained from standard culture. The TaqMan® probe real-time assay can detect as low as 100 fg of B. melitensis DNA, whereas culture from vaginal swab washings has a limit of detection (LOD) of only 1 cfu/ml. Similarly, the visual LAMP assay can detect as low as 10 fg of B. melitensis DNA as compared to an LOD of 30 cfu/ml from culture of vaginal swab washings. Both assays were compared with serological tests (serum tube agglutination test (STAT) and indirect enzyme-linked immunosorbent assay (iELISA)) for diagnostic sensitivity and specificity. Diagnostic sensitivities and specificities for TaqMan® real-time PCR vs. LAMP assays were 98 and 100% vs. 100 and 97.8%, respectively. Results of visual LAMP assay indicated that LAMP is a fast, specific, sensitive, inexpensive and suitable method for diagnosis of B. melitensis infection under field conditions. On the other hand, Omp31 TaqMan® probe real-time assay can be used in conjunction with the other field-based diagnostic tests due to its high specificity.

  12. Diagnostic accuracy of ultrasound in upper and lower extremity long bone fractures of emergency department trauma patients

    PubMed Central

    Frouzan, Arash; Masoumi, Kambiz; Delirroyfard, Ali; Mazdaie, Behnaz; Bagherzadegan, Elnaz

    2017-01-01

    Background Long bone fractures are common injuries caused by trauma. Some studies have demonstrated that ultrasound has a high sensitivity and specificity in the diagnosis of upper and lower extremity long bone fractures. Objective The aim of this study was to determine the accuracy of ultrasound compared with plain radiography in diagnosis of upper and lower extremity long bone fractures in traumatic patients. Methods This cross-sectional study assessed 100 patients admitted to the emergency department of Imam Khomeini Hospital, Ahvaz, Iran with trauma to the upper and lower extremities, from September 2014 through October 2015. In all patients, first ultrasound and then standard plain radiography for the upper and lower limb was performed. Data were analyzed by SPSS version 21 to determine the specificity and sensitivity. Results The mean age of patients with upper and lower limb trauma were 31.43±12.32 years and 29.63±5.89 years, respectively. Radius fracture was the most frequent compared to other fractures (27%). Sensitivity, specificity, positive predicted value, and negative predicted value of ultrasound compared with plain radiography in the diagnosis of upper extremity long bones were 95.3%, 87.7%, 87.2% and 96.2%, respectively, and the highest accuracy was observed in left arm fractures (100%). Tibia and fibula fractures were the most frequent types compared to other fractures (89.2%). Sensitivity, specificity, PPV and NPV of ultrasound compared with plain radiography in the diagnosis of upper extremity long bone fractures were 98.6%, 83%, 65.4% and 87.1%, respectively, and the highest accuracy was observed in men, lower ages and femoral fractures. Conclusion The results of this study showed that ultrasound compared with plain radiography has a high accuracy in the diagnosis of upper and lower extremity long bone fractures. PMID:28979747

  13. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging.

    PubMed

    Walker, Katherine L; Judenhofer, Martin S; Cherry, Simon R; Mitchell, Gregory S

    2015-01-07

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. However, such high-resolution systems have relatively poor sensitivity (typically 0.01-0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With (99m)Tc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system's linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using (99m)Tc MAG-3 and a thyroid scan with (123)I) and one plant study (a (99m)TcO4(-) xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.

  14. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

    DOE PAGES

    Walker, Katherine L.; Judenhofer, Martin S.; Cherry, Simon R.; ...

    2014-12-12

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. Furthermore, such high-resolution systems have relatively poor sensitivity (typically 0.01% to 0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatialmore » resolution, linearity, detection limits, and uniformity. With 99mTc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99mTc MAG-3 and a thyroid scan with 123I) and one plant study (a 99mTcO 4- xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. In conclusion, UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.« less

  15. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

    NASA Astrophysics Data System (ADS)

    Walker, Katherine L.; Judenhofer, Martin S.; Cherry, Simon R.; Mitchell, Gregory S.

    2015-01-01

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. However, such high-resolution systems have relatively poor sensitivity (typically 0.01-0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With 99mTc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99mTc MAG-3 and a thyroid scan with 123I) and one plant study (a 99mTcO4- xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.

  16. The contribution of Ca2+ signaling and Ca2+ sensitivity to the regulation of airway smooth muscle contraction is different in rats and mice.

    PubMed

    Bai, Yan; Sanderson, Michael J

    2009-06-01

    To determine the relative contributions of Ca(2+) signaling and Ca(2+) sensitivity to the contractility of airway smooth muscle cells (SMCs), we compared the contractile responses of mouse and rat airways with the lung slice technique. Airway contraction was measured by monitoring changes in airway lumen area with phase-contrast microscopy, whereas changes in intracellular calcium concentration ([Ca(2+)](i)) of the SMCs were recorded with laser scanning microscopy. In mice and rats, methacholine (MCh) or serotonin induced concentration-dependent airway contraction and Ca(2+) oscillations in the SMCs. However, rat airways demonstrated greater contraction compared with mice, in response to agonist-induced Ca(2+) oscillations of a similar frequency. Because this indicates that rat airway SMCs have a higher Ca(2+) sensitivity compared with mice, we examined Ca(2+) sensitivity with Ca(2+)-permeabilized airway SMCs in which the [Ca(2+)](i) was experimentally controlled. In the absence of agonists, high [Ca(2+)](i) induced a sustained contraction in rat airways but only a transient contraction in mouse airways. This sustained contraction of rat airways was relaxed by Y-23672, a Rho kinase inhibitor, but not affected by GF-109203X, a PKC inhibitor. The subsequent exposure of Ca(2+)-permeabilized airway SMCs, with high [Ca(2+)](i), to MCh elicited a further contraction of rat airways and initiated a sustained contraction of mouse airways, without changing the [Ca(2+)](i) of the SMCs. Collectively, these results indicate that airway SMCs of rats have a substantially higher innate Ca(2+) sensitivity than mice and that this strongly influences the transduction of the frequency of Ca(2+) oscillations into the contractility of airway SMCs.

  17. Validation of search filters for identifying pediatric studies in PubMed.

    PubMed

    Leclercq, Edith; Leeflang, Mariska M G; van Dalen, Elvira C; Kremer, Leontien C M

    2013-03-01

    To identify and validate PubMed search filters for retrieving studies including children and to develop a new pediatric search filter for PubMed. We developed 2 different datasets of studies to evaluate the performance of the identified pediatric search filters, expressed in terms of sensitivity, precision, specificity, accuracy, and number needed to read (NNR). An optimal search filter will have a high sensitivity and high precision with a low NNR. In addition to the PubMed Limits: All Child: 0-18 years filter (in May 2012 renamed to PubMed Filter Child: 0-18 years), 6 search filters for identifying studies including children were identified: 3 developed by Kastner et al, 1 developed by BestBets, one by the Child Health Field, and 1 by the Cochrane Childhood Cancer Group. Three search filters (Cochrane Childhood Cancer Group, Child Health Field, and BestBets) had the highest sensitivity (99.3%, 99.5%, and 99.3%, respectively) but a lower precision (64.5%, 68.4%, and 66.6% respectively) compared with the other search filters. Two Kastner search filters had a high precision (93.0% and 93.7%, respectively) but a low sensitivity (58.5% and 44.8%, respectively). They failed to identify many pediatric studies in our datasets. The search terms responsible for false-positive results in the reference dataset were determined. With these data, we developed a new search filter for identifying studies with children in PubMed with an optimal sensitivity (99.5%) and precision (69.0%). Search filters to identify studies including children either have a low sensitivity or a low precision with a high NNR. A new pediatric search filter with a high sensitivity and a low NNR has been developed. Copyright © 2013 Mosby, Inc. All rights reserved.

  18. Highly antireflective AlGaN/GaN ultraviolet photodetectors using ZnO nanorod arrays on inverted pyramidal surfaces

    NASA Astrophysics Data System (ADS)

    So, Hongyun; Lim, Jongwoo; Suria, Ateeq J.; Senesky, Debbie G.

    2017-07-01

    Highly antireflective heterostructured aluminum gallium nitride (AlGaN)/GaN ultraviolet (UV) photodetectors were demonstrated using a combination of inverted pyramidal surfaces and zinc oxide nanorod arrays (i.e., antireflective surface modification) to enhance the optical sensitivity. The microfabricated hierarchical surfaces significantly reduced the average surface reflectance to less than 0.3% in the UV region and less than 1% in the visible light region, allowing near-perfect absorption of incident light regardless of the angle of incidence (5-80°). As a result, the photodetectors fabricated on highly antireflective AlGaN/GaN surfaces showed higher sensitivity and responsivity over a broad range of incidence angles compared to photodetectors on planar AlGaN/GaN surfaces, supporting the use of a hierarchically modified sensing surface for omnidirectional UV monitoring with higher sensitivity.

  19. Hollow fiber surface plasmon resonance sensor for the detection of liquid with high refractive index.

    PubMed

    Liu, Bing-Hong; Jiang, Yong-Xiang; Zhu, Xiao-Song; Tang, Xiao-Li; Shi, Yi-Wei

    2013-12-30

    A new kind of surface plasmon resonance (SPR) sensor based on silver-coated hollow fiber (HF) structure for the detection of liquids with high refractive index (RI) is presented. Liquid sensed medium with high RI is filled in the hollow core of the HF and its RI can be detected by measuring the transmission spectra of the HF SPR sensor. The designed sensors with different silver thicknesses are fabricated and the transmission spectra for filled liquids with different RI are measured to investigate the performances of the sensors. Theoretical analysis is also carried out to evaluate the performance. The simulation results agree well with the experimental results. Factors that might affect sensitivity and detection accuracy of the sensor are discussed. The highest sensitivity achieved is 6,607 nm/RIU, which is comparable to the sensitivities of the other reported fiber SPR sensors.

  20. Single n+-i-n+ InP nanowires for highly sensitive terahertz detection.

    PubMed

    Peng, Kun; Parkinson, Patrick; Gao, Qian; Boland, Jessica L; Li, Ziyuan; Wang, Fan; Mokkapati, Sudha; Fu, Lan; Johnston, Michael B; Tan, Hark Hoe; Jagadish, Chennupati

    2017-03-24

    Developing single-nanowire terahertz (THz) electronics and employing them as sub-wavelength components for highly-integrated THz time-domain spectroscopy (THz-TDS) applications is a promising approach to achieve future low-cost, highly integrable and high-resolution THz tools, which are desirable in many areas spanning from security, industry, environmental monitoring and medical diagnostics to fundamental science. In this work, we present the design and growth of n + -i-n + InP nanowires. The axial doping profile of the n + -i-n + InP nanowires has been calibrated and characterized using combined optical and electrical approaches to achieve nanowire devices with low contact resistances, on which the highly-sensitive InP single-nanowire photoconductive THz detectors have been demonstrated. While the n + -i-n + InP nanowire detector has a only pA-level response current, it has a 2.5 times improved signal-to-noise ratio compared with the undoped InP nanowire detector and is comparable to traditional bulk THz detectors. This performance indicates a promising path to nanowire-based THz electronics for future commercial applications.

  1. Cost-effectiveness of WHO-Recommended Algorithms for TB Case Finding at Ethiopian HIV Clinics.

    PubMed

    Adelman, Max W; McFarland, Deborah A; Tsegaye, Mulugeta; Aseffa, Abraham; Kempker, Russell R; Blumberg, Henry M

    2018-01-01

    The World Health Organization (WHO) recommends active tuberculosis (TB) case finding and a rapid molecular diagnostic test (Xpert MTB/RIF) to detect TB among people living with HIV (PLHIV) in high-burden settings. Information on the cost-effectiveness of these recommended strategies is crucial for their implementation. We conducted a model-based cost-effectiveness analysis comparing 2 algorithms for TB screening and diagnosis at Ethiopian HIV clinics: (1) WHO-recommended symptom screen combined with Xpert for PLHIV with a positive symptom screen and (2) current recommended practice algorithm (CRPA; based on symptom screening, smear microscopy, and clinical TB diagnosis). Our primary outcome was US$ per disability-adjusted life-year (DALY) averted. Secondary outcomes were additional true-positive diagnoses, and false-negative and false-positive diagnoses averted. Compared with CRPA, combining a WHO-recommended symptom screen with Xpert was highly cost-effective (incremental cost of $5 per DALY averted). Among a cohort of 15 000 PLHIV with a TB prevalence of 6% (900 TB cases), this algorithm detected 8 more true-positive cases than CRPA, and averted 2045 false-positive and 8 false-negative diagnoses compared with CRPA. The WHO-recommended algorithm was marginally costlier ($240 000) than CRPA ($239 000). In sensitivity analysis, the symptom screen/Xpert algorithm was dominated at low Xpert sensitivity (66%). In this model-based analysis, combining a WHO-recommended symptom screen with Xpert for TB diagnosis among PLHIV was highly cost-effective ($5 per DALY averted) and more sensitive than CRPA in a high-burden, resource-limited setting.

  2. Evaluation of the Abbott RealTime MTB and RealTime MTB INH/RIF Assays for Direct Detection of Mycobacterium tuberculosis Complex and Resistance Markers in Respiratory and Extrapulmonary Specimens.

    PubMed

    Hofmann-Thiel, Sabine; Molodtsov, Nikolay; Antonenka, Uladzimir; Hoffmann, Harald

    2016-12-01

    The Abbott RealTime MTB (RT MTB) assay is a new automated nucleic acid amplification test for the detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. In combination with the RealTime MTB INH/RIF (RT MTB INH/RIF) resistance assay, which can be applied to RT MTB-positive specimens as an add-on assay, the tests also indicate the genetic markers of resistance to isoniazid (INH) and rifampin (RIF). We aimed to evaluate the diagnostic sensitivity and specificity of RT MTB using different types of respiratory and extrapulmonary specimens and to compare performance characteristics directly with those of the FluoroType MTB assay. The resistance results obtained by RT MTB INH/RIF were compared to those from the GenoType MTBDRplus and from phenotypic drug susceptibility testing. A total of 715 clinical specimens were analyzed. Compared to culture, the overall sensitivity of RT MTB was 92.1%; the sensitivity rates for smear-positive and smear-negative samples were 100% and 76.2%, respectively. The sensitivities of smear-negative specimens were almost identical for respiratory (76.3%) and extrapulmonary (76%) specimens. Specificity rates were 100% and 95.8% for culture-negative specimens and those that grew nontuberculous mycobacteria, respectively. RT MTB INH/RIF was applied to 233 RT MTB-positive samples and identified resistance markers in 7.7% of samples. Agreement with phenotypic and genotypic drug susceptibility testing was 99.5%. In conclusion, RT MTB and RT MTB INH/RIF allow for the rapid and accurate diagnosis of tuberculosis (TB) in different types of specimens and reliably indicate resistance markers. The strengths of this system are the comparably high sensitivity with paucibacillary specimens, its ability to detect INH and RIF resistance, and its high-throughput capacities. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  3. Favorable effects of carotid endarterectomy on baroreflex sensitivity and cardiovascular neural modulation: a 4-month follow-up.

    PubMed

    Dalla Vecchia, Laura; Barbic, Franca; Galli, Andrea; Pisacreta, Massimo; Gornati, Rosella; Porretta, Tiziano; Porta, Alberto; Furlan, Raffaello

    2013-06-15

    Carotid surgery variably modifies carotid afferent innervation, thus affecting arterial baroreceptor sensitivity. Low arterial baroreflex sensitivity is a well-known independent risk factor for cardiovascular diseases. The aim of this study was to assess the 4-mo effects of carotid endarterectomy (CEA) on arterial baroreceptor sensitivity and cardiovascular autonomic profile in patients with unilateral carotid stenosis. We enrolled 20 patients (72 ± 8 yr) with unilateral >70% carotid stenosis. ECG, beat-by-beat blood pressure, and respiration were continuously recorded before and 126 ± 9 days after CEA, at rest and during a 75° head-up tilt. Both pharmacological (modified Oxford technique, BRS) and spontaneous (index α, spectral analysis) arterial baroreflex sensitivity were assessed. Cardiovascular autonomic profile was evaluated by plasma catecholamines and spectral indexes of cardiac sympathovagal modulation [low-frequency R-R interval (LFRR), low frequency-to high frequency ratio (LF/HF), high-frequency R-R interval (HFRR)] and sympathetic vasomotor control [low-frequency systolic arterial pressure (LFSAP)] obtained from heart rate and SAP variability. After CEA, both the index α and BRS were higher (P < 0.02) at rest. SAP variance decreased both at rest and during tilt (P < 0.02). Before surgery, tilt did not modify the autonomic profile compared with baseline. After CEA, tilt increased LF/HF and LFSAP and reduced HFRR compared with rest (P < 0.02). Four months after CEA was performed, arterial baroreflex sensitivity was enhanced. Accordingly, the patients' autonomic profile had shifted toward reduced cardiac and vascular sympathetic activation and enhanced cardiac vagal activity. The capability to increase cardiovascular sympathetic activation in response to orthostasis was restored. Baroreceptor sensitivity improvement might play an additional role in the more favorable outcome observed in patients after carotid surgery.

  4. Low Insertion Loss and Highly Sensitive SH-SAW Sensors Based on 36° YX LiTaO 3 Through the Incorporation of Filled Microcavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, Mandek; Sankaranarayanan, Subramanian K. R. S.; Bhethanabotla, Venkat R.

    2015-02-01

    Reduction in power consumption and improvement in mass sensitivity are important considerations for surface acoustic wave (SAW) devices used in various sensing applications. Detection of minute quantities of a particular species (clinical sensing) and power requirements (wireless sensing) are two key metrics that must be optimized. In this paper, a 3-D finite element model (FEM) was employed to compare insertion loss (IL) and mass sensitivity of SAW sensors having microcavities filled with ZnO and nanocrystalline diamond to a standard two-port SAW design. Initial simulation results show that ZnO filled cavities (depth = 5 mu m) were most effective at reducingmore » power loss Delta IL = (6.03 dB) by increasing particle displacement (acousto-electric to mechanical transduction) at the output transducer. A 100-pg/cm(2) load was applied to the sensing area of each device to evaluate mass sensitivity. Our simulations suggest that ZnO filled cavities with shallow depth (2.5 mu m) have the greatest sensitivity. The FEM simulations are used to understand the acoustic wave propagation in microcavity-based SAW sensors. The observed enhancement in mass sensitivity and power transfer is attributed to waveguiding effects and constructive interference of the scattered acoustic waves from the microcavities. Devices fabricated with microcavities similar to 1 mu m deep decreased IL by 3.306 dB compared with a standard SAW device. Additional simulations were conducted for each device configuration using the same depth in order to make a direct comparison between measured and simulated results. Our findings offer encouraging prospects for designing low IL highly sensitive microcavity-based SAW biosensors.« less

  5. Role of reactive oxygen species in the anticancer activity of botanicals: Comparing sensitivity profiles

    PubMed Central

    Cohen, Zoya; Maimon, Yair; Samuels, Noah; Berger, Raanan

    2017-01-01

    Numerous botanicals have been shown to exhibit in vitro and in vivo anticancer activity, some of which is the result of the induction of reactive oxygen species (ROS) in cancer cells with a high ROS content. The present study compared sensitivities to a series of botanicals among cancer cell lines, using an XTT viability test, in order to create a specific cancer-herb profile. Of the 27 botanicals screened, 10 exhibited a cytotoxic effect, 7 of which were ROS-mediated. The sensitivity profiles of the ROS-inducing botanicals in 10 cancer cell lines were similar, unlike 3 cytotoxic ROS-independent botanicals that displayed divergent botanical-specific profiles. The correlation between sensitivity profiles of ROS-inducing botanicals suggests a common mechanism of action, in contrast to the varied mechanism of ROS-independent botanicals. This implies that the investigation of the anticancer activity of botanicals should start with the examination of ROS-mediated activity. Further investigation of ROS sensitivity among various tumor types is required in order to guide research into developing evidence-based guidelines in the use of botanicals for cancer treatment. PMID:28454445

  6. Sensitivity and specificity of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium: A single-center study in Japan.

    PubMed

    Nishimura, Katsuji; Yokoyama, Kanako; Yamauchi, Noriko; Koizumi, Masako; Harasawa, Nozomi; Yasuda, Taeko; Mimura, Chizuru; Igita, Hazuki; Suzuki, Eriko; Uchiide, Yoko; Seino, Yusuke; Nomura, Minoru; Yamazaki, Kenji; Ishigooka, Jun

    2016-01-01

    To compare the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium. These tools have not been tested in a specialized cardio-surgical ICU. Sensitivities and specificities of each tool were assessed in a cardio-surgical ICU in Japan by two trained nurses independently. Results were compared with delirium diagnosed by psychiatrists using the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision. There were 110 daily, paired assessments in 31 patients. The CAM-ICU showed 38% sensitivity and 100% specificity for both nurses. All 20 false-negative cases resulted from high scores in the auditory attention screening in CAM-ICU. The ICDSC showed 97% and 94% sensitivity, and 97% and 91% specificity for the two nurses (cutoff ≥4). In a Japanese cardio-surgical ICU, the ICDSC had a higher sensitivity than the CAM-ICU. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Effects of anxiety sensitivity and expectations on the modulation of the startle eyeblink response during a caffeine challenge.

    PubMed

    Benke, Christoph; Blumenthal, Terry D; Modeß, Christiane; Hamm, Alfons O; Pané-Farré, Christiane A

    2015-09-01

    The way in which the tendency to fear somatic arousal sensations (anxiety sensitivity), in interaction with the created expectations regarding arousal induction, might affect defensive responding to a symptom provocation challenge is not yet understood. The present study investigated the effect of anxiety sensitivity on autonomic arousal, startle eyeblink responses, and reported arousal and alertness to expected vs. unexpected caffeine consumption. To create a match/mismatch of expected and experienced arousal, high and low anxiety sensitive participants received caffeine vs. no drug either mixed in coffee (expectation of arousal induction) or in bitter lemon soda (no expectation of arousal induction) on four separate occasions. Autonomic arousal (heart rate, skin conductance level), respiration (end-tidal CO2, minute ventilation), defensive reflex responses (startle eyeblink), and reported arousal and alertness were recorded prior to, immediately and 30 min after beverage ingestion. Caffeine increased ventilation, autonomic arousal, and startle response magnitudes. Both groups showed comparable levels of autonomic and respiratory responses. The startle eyeblink responses were decreased when caffeine-induced arousal occurred unexpectedly, e.g., after administering caffeine in bitter lemon. This effect was more accentuated in high anxiety sensitive persons. Moreover, in high anxiety sensitive persons, the expectation of arousal (coffee consumption) led to higher subjective alertness when administering caffeine and increased arousal even if no drug was consumed. Unexpected symptom provocation leads to increased attention allocation toward feared arousal sensations in high anxiety sensitive persons. This finding broadens our understanding of modulatory mechanisms in defensive responding to bodily symptoms.

  8. Observed and predicted sensitivities of extreme surface ozone to meteorological drivers in three US cities

    NASA Astrophysics Data System (ADS)

    Fix, Miranda J.; Cooley, Daniel; Hodzic, Alma; Gilleland, Eric; Russell, Brook T.; Porter, William C.; Pfister, Gabriele G.

    2018-03-01

    We conduct a case study of observed and simulated maximum daily 8-h average (MDA8) ozone (O3) in three US cities for summers during 1996-2005. The purpose of this study is to evaluate the ability of a high resolution atmospheric chemistry model to reproduce observed relationships between meteorology and high or extreme O3. We employ regional coupled chemistry-transport model simulations to make three types of comparisons between simulated and observational data, comparing (1) tails of the O3 response variable, (2) distributions of meteorological predictor variables, and (3) sensitivities of high and extreme O3 to meteorological predictors. This last comparison is made using two methods: quantile regression, for the 0.95 quantile of O3, and tail dependence optimization, which is used to investigate even higher O3 extremes. Across all three locations, we find substantial differences between simulations and observational data in both meteorology and meteorological sensitivities of high and extreme O3.

  9. Can optical diagnosis of small colon polyps be accurate? Comparing standard scope without narrow banding to high definition scope with narrow banding.

    PubMed

    Ashktorab, Hassan; Etaati, Firoozeh; Rezaeean, Farahnaz; Nouraie, Mehdi; Paydar, Mansour; Namin, Hassan Hassanzadeh; Sanderson, Andrew; Begum, Rehana; Alkhalloufi, Kawtar; Brim, Hassan; Laiyemo, Adeyinka O

    2016-07-28

    To study the accuracy of using high definition (HD) scope with narrow band imaging (NBI) vs standard white light colonoscope without NBI (ST), to predict the histology of the colon polyps, particularly those < 1 cm. A total of 147 African Americans patients who were referred to Howard University Hospital for screening or, diagnostic or follow up colonoscopy, during a 12-mo period in 2012 were prospectively recruited. Some patients had multiple polyps and total number of polyps was 179. Their colonoscopies were performed by 3 experienced endoscopists who determined the size and stated whether the polyps being removed were hyperplastic or adenomatous polyps using standard colonoscopes or high definition colonoscopes with NBI. The histopathologic diagnosis was reported by pathologists as part of routine care. Of participants in the study, 55 (37%) were male and median (interquartile range) of age was 56 (19-80). Demographic, clinical characteristics, past medical history of patients, and the data obtained by two instruments were not significantly different and two methods detected similar number of polyps. In ST scope 89% of polyps were < 1 cm vs 87% in HD scope (P = 0.7). The ST scope had a positive predictive value (PPV) and positive likelihood ratio (PLR) of 86% and 4.0 for adenoma compared to 74% and 2.6 for HD scope. There was a trend of higher sensitivity for HD scope (68%) compare to ST scope (53%) with almost the same specificity. The ST scope had a PPV and PLR of 38% and 1.8 for hyperplastic polyp (HPP) compared to 42% and 2.2 for HD scope. The sensitivity and specificity of two instruments for HPP diagnosis were similar. Our results indicated that HD scope was more sensitive in diagnosis of adenoma than ST scope. Clinical diagnosis of HPP with either scope is less accurate compared to adenoma. Colonoscopy diagnosis is not yet fully matched with pathologic diagnosis of colon polyp. However with the advancement of both imaging and training, it may be possible to increase the sensitivity and specificity of the scopes and hence save money for eliminating time and the cost of Immunohistochemistry/pathology.

  10. Detection of high-risk mucosal human papillomavirus DNA in human specimens by a novel and sensitive multiplex PCR method combined with DNA microarray.

    PubMed

    Gheit, Tarik; Tommasino, Massimo

    2011-01-01

    Epidemiological and functional studies have clearly demonstrated that certain types of human papillomavirus (HPV) from the genus alpha of the HPV phylogenetic tree, referred to as high-risk (HR) types, are the etiological cause of cervical cancer. Several methods for HPV detection and typing have been developed, and their importance in clinical and epidemiological studies has been well demonstrated. However, comparative studies have shown that several assays have different sensitivities for the detection of specific HPV types, particularly in the case of multiple infections. In this chapter, we describe a novel one-shot method for the detection and typing of 19 mucosal HR HPV types (types 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 70, 73, and 82). The assay combines the advantages of the multiplex PCR methods, i.e., high sensitivity and the possibility to perform multiple amplifications in a single reaction, with an array primer extension (APEX) assay. The latter method offers the benefits of Sanger dideoxy sequencing with the high-throughput potential of the microarray. Initial studies have revealed that the assay is very sensitive in detecting multiple HPV infections.

  11. Influence of dietary protein content and source on colonic fermentative activity in dogs differing in body size and digestive tolerance.

    PubMed

    Nery, J; Goudez, R; Biourge, V; Tournier, C; Leray, V; Martin, L; Thorin, C; Nguyen, P; Dumon, H

    2012-08-01

    Low-consistency, high-moisture feces have been observed in large dogs (Canis lupus familiaris), compared with small dogs, and particularly in sensitive breeds (e.g., German Shepherd dogs). The aim of this work was to determine if greater colonic protein fermentation is responsible for poorer fecal quality in large sensitive dogs. Twenty-seven bitches were allotted to 4 groups based on size and digestive sensitivity: small, medium, large tolerant, and large sensitive. Five experimental diets varying in protein source [highly digestible wheat gluten (WG) vs. medium digestible poultry meal (PM), and protein concentration from 21.4 to 21.6 (LP) to 38.2 to 39.2% CP (HP)] were tested. Diets were fed for 14 d and followed by a 12-d transition period. Digestive fermentation by-products were investigated in fresh stools [ammonia, phenol, indole, and short chain fatty acids including acetate, propionate, and butyrate (C2 to C4 SCFA), branched-chain fatty acids (BCFA), and valerate] and in urine (phenol and indole). Bacterial populations in feces were identified. The PM diets resulted in greater fecal concentrations of ammonia, BCFA, valerate, indole, and C2 to C4 SCFA than WG diets (P = 0.002, P < 0.001, P = 0.039, P = 0.003, and P = 0.012, respectively). Greater concentrations of ammonia, BCFA, and valerate were found in the feces of dogs fed HP compared with LP diets (P < 0.001, P < 0.001, and P = 0.012, respectively). The concentrations of ammonia, valerate, phenol, and indole in feces of large sensitive dogs were greater (P < 0.001, P < 0.001, P = 0.002, and P = 0.019, respectively) compared with the other groups. The Enterococcus populations were greater in feces of dogs fed with PMHP rather than WGLP diets (P = 0.006). Urinary phenol and indole excretion was greater when dogs were fed PM than WG diets (P < 0.001 and P = 0.038, respectively) and HP than LP diets (P = 0.001 and P = 0.087, respectively). Large sensitive dogs were prone to excrete a greater quantity of phenol in urine (P < 0.001). A diet formulated with highly digestible protein, such as WG, led to reduced concentrations of protein-based fermentation products in feces together with improved fecal quality in dogs, especially in large sensitive ones. Poor fecal quality in large sensitive dogs could be partly related to the pattern of protein fermentation in the hindgut.

  12. Detection of compression vessels in trigeminal neuralgia by surface-rendering three-dimensional reconstruction of 1.5- and 3.0-T magnetic resonance imaging.

    PubMed

    Shimizu, Masahiro; Imai, Hideaki; Kagoshima, Kaiei; Umezawa, Eriko; Shimizu, Tsuneo; Yoshimoto, Yuhei

    2013-01-01

    Surface-rendered three-dimensional (3D) 1.5-T magnetic resonance (MR) imaging is useful for presurgical simulation of microvascular decompression. This study compared the sensitivity and specificity of 1.5- and 3.0-T surface-rendered 3D MR imaging for preoperative identification of the compression vessels of trigeminal neuralgia. One hundred consecutive patients underwent microvascular decompression for trigeminal neuralgia. Forty and 60 patients were evaluated by 1.5- and 3.0-T MR imaging, respectively. Three-dimensional MR images were constructed on the basis of MR imaging, angiography, and venography data and evaluated to determine the compression vessel before surgery. MR imaging findings were compared with the microsurgical findings to compare the sensitivity and specificity of 1.5- and 3.0-T MR imaging. The agreement between MR imaging and surgical findings depended on the compression vessels. For superior cerebellar artery, 1.5- and 3.0-T MR imaging had 84.4% and 82.7% sensitivity and 100% and 100% specificity, respectively. For anterior inferior cerebellar artery, 1.5- and 3.0-T MR imaging had 33.3% and 50% sensitivity and 92.9% and 95% specificity, respectively. For the petrosal vein, 1.5- and 3.0-T MR imaging had 75% and 64.3% sensitivity and 79.2% and 78.1% specificity, respectively. Complete pain relief was obtained in 36 of 40 and 55 of 60 patients undergoing 1.5- and 3.0-T MR imaging, respectively. The present study showed that both 1.5- and 3.0-T MR imaging provided high sensitivity and specificity for preoperative assessment of the compression vessels of trigeminal neuralgia. Preoperative 3D imaging provided very high quality presurgical simulation, resulting in excellent clinical outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Nanoplasmonic biochips for rapid label-free detection of imidacloprid pesticides with a smartphone.

    PubMed

    Lee, Kuang-Li; You, Meng-Lin; Tsai, Chia-Hsin; Lin, En-Hung; Hsieh, Shu-Yi; Ho, Ming-Hsun; Hsu, Ju-Chun; Wei, Pei-Kuen

    2016-01-15

    The widespread and intensive use of neonicotinoid insecticides induces negative cascading effects on ecosystems. It is desirable to develop a portable sensitive sensing platform for on-site screening of high-risk pesticides. We combined an indirect competitive immunoassay, highly sensitive surface plasmon resonance (SPR) biochip and a simple portable imaging setup for label-free detection of imidacloprid pesticides. The SPR biochip consists of several capped nanoslit arrays with different periods which form a spectral image on the chip. The qualitative and semiquantitative analyses of pesticides can be directly observed from the spot shift on the chip. The precise semiquantitative analyses can be further completed by using image processing in a smartphone. We demonstrate simultaneous detection of four different concentrations of imidacloprid pesticides. The visual detection limit is about 1ppb, which is well below the maximum residue concentration permitted by law (20ppb). Compared to the one-step strip assay, the proposed chip is capable of performing semiquantitative analyses and multiple detection. Compared to the enzyme-linked immunosorbent assay, our method is label-free and requires simple washing steps and short reaction time. In addition, the label-free chip has a comparable sensitivity but wider working range than those labeling techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    PubMed

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  15. Metabolic syndrome and salt sensitivity of blood pressure in non-diabetic people in China: a dietary intervention study.

    PubMed

    Chen, Jing; Gu, Dongfeng; Huang, Jianfeng; Rao, Dabeeru C; Jaquish, Cashell E; Hixson, James E; Chen, Chung-Shiuan; Chen, Jichun; Lu, Fanghong; Hu, Dongsheng; Rice, Treva; Kelly, Tanika N; Hamm, L Lee; Whelton, Paul K; He, Jiang

    2009-03-07

    Since insulin resistance is thought to be the underlying mechanism for metabolic syndrome, affected individuals might be sensitive to a dietary sodium intervention. We aimed to examine the association between metabolic syndrome and salt sensitivity of blood pressure. 1906 Chinese participants without diabetes, aged 16 years or more, were selected to receive a low-sodium diet (51.3 mmol per day) for 7 days followed by a high-sodium diet (307.8 mmol per day) for an additional 7 days. Participants were excluded from the analysis if metabolic risk factor information was missing or if they did not complete their dietary interventions. Blood pressure was measured at baseline and on days 2, 5, 6, and 7 of each intervention. Metabolic syndrome was defined as the presence of three or more of: abdominal obesity, raised blood pressure, high triglyceride concentration, low HDL cholesterol, or high glucose. High salt sensitivity was defined as a decrease in mean arterial blood pressure of more than 5 mm Hg during low-sodium or an increase of more than 5 mm Hg during high-sodium intervention. This study is registered with ClinicalTrials.gov, number NCT00721721. Of the 1881 participants with information regarding metabolic syndrome, 283 had metabolic syndrome. 1853 participants completed the low-sodium diet and 1845 completed the high-sodium diet. Multivariable-adjusted mean changes in blood pressure were significantly greater in participants with metabolic syndrome than in those without on both low-sodium and high-sodium diets (p<0.0001 for all comparisons). Additionally, risk of salt sensitivity rose with increasing numbers of risk factors for metabolic syndrome. Compared with those with no risk factors, participants with four or five had a 3.54-fold increased odds (95% CI 2.05-6.11) of high salt-sensitivity during the low-sodium and a 3.13-fold increased odds (1.80-5.43) of high salt-sensitivity during the high-sodium intervention. These results suggest that metabolic syndrome enhances blood pressure response to sodium intake. Reduction in sodium intake could be an especially important component in reducing blood pressure in patients with multiple risk factors for metabolic syndrome.

  16. Low-Temperature Photochemically Activated Amorphous Indium-Gallium-Zinc Oxide for Highly Stable Room-Temperature Gas Sensors.

    PubMed

    Jaisutti, Rawat; Kim, Jaeyoung; Park, Sung Kyu; Kim, Yong-Hoon

    2016-08-10

    We report on highly stable amorphous indium-gallium-zinc oxide (IGZO) gas sensors for ultraviolet (UV)-activated room-temperature detection of volatile organic compounds (VOCs). The IGZO sensors fabricated by a low-temperature photochemical activation process and exhibiting two orders higher photocurrent compared to conventional zinc oxide sensors, allowed high gas sensitivity against various VOCs even at room temperature. From a systematic analysis, it was found that by increasing the UV intensity, the gas sensitivity, response time, and recovery behavior of an IGZO sensor were strongly enhanced. In particular, under an UV intensity of 30 mW cm(-2), the IGZO sensor exhibited gas sensitivity, response time and recovery time of 37%, 37 and 53 s, respectively, against 750 ppm concentration of acetone gas. Moreover, the IGZO gas sensor had an excellent long-term stability showing around 6% variation in gas sensitivity over 70 days. These results strongly support a conclusion that a low-temperature solution-processed amorphous IGZO film can serve as a good candidate for room-temperature VOCs sensors for emerging wearable electronics.

  17. Engineering 'cell robots' for parallel and highly sensitive screening of biomolecules under in vivo conditions.

    PubMed

    Song, Lifu; Zeng, An-Ping

    2017-11-09

    Cells are capable of rapid replication and performing tasks adaptively and ultra-sensitively and can be considered as cheap "biological-robots". Here we propose to engineer cells for screening biomolecules in parallel and with high sensitivity. Specifically, we place the biomolecule variants (library) on the bacterial phage M13. We then design cells to screen the library based on cell-phage interactions mediated by a specific intracellular signal change caused by the biomolecule of interest. For proof of concept, we used intracellular lysine concentration in E. coli as a signal to successfully screen variants of functional aspartate kinase III (AK-III) under in vivo conditions, a key enzyme in L-lysine biosynthesis which is strictly inhibited by L-lysine. Comparative studies with flow cytometry method failed to distinguish the wild-type from lysine resistance variants of AK-III, confirming a higher sensitivity of the method. It opens up a new and effective way of in vivo high-throughput screening for functional molecules and can be easily implemented at low costs.

  18. Refractive index sensing characteristics of carbon nanotube-deposited photonic crystal fiber SPR sensor

    NASA Astrophysics Data System (ADS)

    Jing, Jian-Ying; Wang, Qi; Wang, Bo-Tao

    2018-07-01

    In this paper, the carbon nanotubes (CNTs)-deposited Au film photonic crystal fiber (PCF) surface plasmon resonance (SPR) sensor (CNTs/Au-PCF sensor) and CNTs-deposited Ag film PCF SPR sensor (CNTs/Ag-PCF sensor) were developed and utilized to conduct a series of experiments for the refractive index sensing characteristics study of the CNTs-deposited SPR sensors. The PCF, spliced between two sections of multimode fibers (MMFs), was coated with a metal (Au or Ag) film and then deposited with CNTs for further sensing. CNTs coating can enhance the confined electric field intensity surrounding the sensing layer, making the SPR sensor more sensitive to the changes in the ambient medium. Compared with conventional Au film PCF SPR sensor (Au-PCF sensor), the sensitivity of CNTs/Au-PCF sensor increases by 1016.09 nm/RIU. Compared with conventional Ag film PCF SPR sensor (Ag-PCF sensor), the sensitivity of CNTs/Ag-PCF sensor increases by 709.22 nm/RIU. Therefore, we find that CNTs have a more significant effect on the Au-PCF sensor than the Ag-PCF sensor. The experimental measurements results agreed well with the simulation results. Furthermore, CNTs have high surface-to-volume ratio and extremely excellent biocompatibility. Bovine serum albumin (BSA) was employed as the target analyte to evaluate the feasibility of the CNTs/Au-PCF sensor for the detection of biomolecules, and the sensor exhibits higher sensitivity (8.18 nm/(mg/mL)), lower limit of detection (LOD) (2.5 μg/mL), and faster response time (8 s) than the Au-PCF sensor. Such CNTs-deposited SPR sensors with high sensitivities and fast response present highly promising potential for application in the field of biochemistry.

  19. Performance of a High-Sensitivity Rapid Diagnostic Test for Plasmodium falciparum Malaria in Asymptomatic Individuals from Uganda and Myanmar and Naive Human Challenge Infections.

    PubMed

    Das, Smita; Jang, Ihn Kyung; Barney, Becky; Peck, Roger; Rek, John C; Arinaitwe, Emmanuel; Adrama, Harriet; Murphy, Maxwell; Imwong, Mallika; Ling, Clare L; Proux, Stephane; Haohankhunnatham, Warat; Rist, Melissa; Seilie, Annette M; Hanron, Amelia; Daza, Glenda; Chang, Ming; Nakamura, Tomoka; Kalnoky, Michael; Labarre, Paul; Murphy, Sean C; McCarthy, James S; Nosten, Francois; Greenhouse, Bryan; Allauzen, Sophie; Domingo, Gonzalo J

    2017-11-01

    Sensitive field-deployable diagnostic tests can assist malaria programs in achieving elimination. The performance of a new Alere™ Malaria Ag P.f Ultra Sensitive rapid diagnostic test (uRDT) was compared with the currently available SD Bioline Malaria Ag P.f RDT in blood specimens from asymptomatic individuals in Nagongera, Uganda, and in a Karen Village, Myanmar, representative of high- and low-transmission areas, respectively, as well as in pretreatment specimens from study participants from four Plasmodium falciparum -induced blood-stage malaria (IBSM) studies. A quantitative reverse transcription PCR (qRT-PCR) and a highly sensitive enzyme-linked immunosorbent assay (ELISA) test for histidine-rich protein II (HRP2) were used as reference assays. The uRDT showed a greater than 10-fold lower limit of detection for HRP2 compared with the RDT. The sensitivity of the uRDT was 84% and 44% against qRT-PCR in Uganda and Myanmar, respectively, and that of the RDT was 62% and 0% for the same two sites. The specificities of the uRDT were 92% and 99.8% against qRT-PCR for Uganda and Myanmar, respectively, and 99% and 99.8% against the HRP2 reference ELISA. The RDT had specificities of 95% and 100% against qRT-PCR for Uganda and Myanmar, respectively, and 96% and 100% against the HRP2 reference ELISA. The uRDT detected new infections in IBSM study participants 1.5 days sooner than the RDT. The uRDT has the same workflow as currently available RDTs, but improved performance characteristics to identify asymptomatic malaria infections. The uRDT may be a useful tool for malaria elimination strategies.

  20. Performance of a High-Sensitivity Rapid Diagnostic Test for Plasmodium falciparum Malaria in Asymptomatic Individuals from Uganda and Myanmar and Naive Human Challenge Infections

    PubMed Central

    Das, Smita; Jang, Ihn Kyung; Barney, Becky; Peck, Roger; Rek, John C.; Arinaitwe, Emmanuel; Adrama, Harriet; Murphy, Maxwell; Imwong, Mallika; Ling, Clare L.; Proux, Stephane; Haohankhunnatham, Warat; Rist, Melissa; Seilie, Annette M.; Hanron, Amelia; Daza, Glenda; Chang, Ming; Nakamura, Tomoka; Kalnoky, Michael; Labarre, Paul; Murphy, Sean C.; McCarthy, James S.; Nosten, Francois; Greenhouse, Bryan; Allauzen, Sophie; Domingo, Gonzalo J.

    2017-01-01

    Abstract. Sensitive field-deployable diagnostic tests can assist malaria programs in achieving elimination. The performance of a new Alere™ Malaria Ag P.f Ultra Sensitive rapid diagnostic test (uRDT) was compared with the currently available SD Bioline Malaria Ag P.f RDT in blood specimens from asymptomatic individuals in Nagongera, Uganda, and in a Karen Village, Myanmar, representative of high- and low-transmission areas, respectively, as well as in pretreatment specimens from study participants from four Plasmodium falciparum-induced blood-stage malaria (IBSM) studies. A quantitative reverse transcription PCR (qRT-PCR) and a highly sensitive enzyme-linked immunosorbent assay (ELISA) test for histidine-rich protein II (HRP2) were used as reference assays. The uRDT showed a greater than 10-fold lower limit of detection for HRP2 compared with the RDT. The sensitivity of the uRDT was 84% and 44% against qRT-PCR in Uganda and Myanmar, respectively, and that of the RDT was 62% and 0% for the same two sites. The specificities of the uRDT were 92% and 99.8% against qRT-PCR for Uganda and Myanmar, respectively, and 99% and 99.8% against the HRP2 reference ELISA. The RDT had specificities of 95% and 100% against qRT-PCR for Uganda and Myanmar, respectively, and 96% and 100% against the HRP2 reference ELISA. The uRDT detected new infections in IBSM study participants 1.5 days sooner than the RDT. The uRDT has the same workflow as currently available RDTs, but improved performance characteristics to identify asymptomatic malaria infections. The uRDT may be a useful tool for malaria elimination strategies. PMID:28820709

  1. Evaluation of the highly sensitive Roche thyroglobulin II assay and establishment of a reference limit for thyroglobulin-negative patient samples.

    PubMed

    Rotteveel-de Groot, Dorien M; Ross, H Alec; Janssen, Marcel J R; Netea-Maier, Romana T; Oosting, Janine D; Sweep, Fred C G J; van Herwaarden, Antonius E

    2016-08-01

    Thyroglobulin (Tg) measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC) after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman-Coulter). Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI) evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL) for the Elecsys Tg II assay. Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04-500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence.

  2. High sensitive vectorial B-probe for low frequency plasma waves.

    PubMed

    Ullrich, Stefan; Grulke, Olaf; Klinger, Thomas; Rahbarnia, Kian

    2013-11-01

    A miniaturized multidimensional magnetic probe is developed for application in a low-temperature plasma environment. A very high sensitivity for low-frequency magnetic field fluctuations with constant phase run, a very good signal-to-noise ratio combined with an efficient electrostatic pickup rejection, renders the probe superior compared with any commercial solution. A two-step calibration allows for absolute measurement of amplitude and direction of magnetic field fluctuations. The excellent probe performance is demonstrated by measurements of the parallel current pattern of coherent electrostatic drift wave modes in the VINETA (versatile instrument for studies on nonlinearity, electromagnetism, turbulence, and applications) experiment.

  3. Signal processing system for electrotherapy applications

    NASA Astrophysics Data System (ADS)

    Płaza, Mirosław; Szcześniak, Zbigniew

    2017-08-01

    The system of signal processing for electrotherapeutic applications is proposed in the paper. The system makes it possible to model the curve of threshold human sensitivity to current (Dalziel's curve) in full medium frequency range (1kHz-100kHz). The tests based on the proposed solution were conducted and their results were compared with those obtained according to the assumptions of High Tone Power Therapy method and referred to optimum values. Proposed system has high dynamics and precision of mapping the curve of threshold human sensitivity to current and can be used in all methods where threshold curves are modelled.

  4. In-vacuum scattered light reduction with black cupric oxide surfaces for sensitive fluorescence detection.

    PubMed

    Norrgard, E B; Sitaraman, N; Barry, J F; McCarron, D J; Steinecker, M H; DeMille, D

    2016-05-01

    We demonstrate a simple and easy method for producing low-reflectivity surfaces that are ultra-high vacuum compatible, may be baked to high temperatures, and are easily applied even on complex surface geometries. Black cupric oxide (CuO) surfaces are chemically grown in minutes on any copper surface, allowing for low-cost, rapid prototyping, and production. The reflective properties are measured to be comparable to commercially available products for creating optically black surfaces. We describe a vacuum apparatus which uses multiple blackened copper surfaces for sensitive, low-background detection of molecules using laser-induced fluorescence.

  5. Patient Satisfaction and Nipple-Areola Sensitivity After Bilateral Prophylactic Mastectomy and Immediate Implant Breast Reconstruction in a High Breast Cancer Risk Population: Nipple-Sparing Mastectomy Versus Skin-Sparing Mastectomy.

    PubMed

    van Verschuer, Victorien M T; Mureau, Marc A M; Gopie, Jessica P; Vos, Elvira L; Verhoef, Cornelis; Menke-Pluijmers, Marian B E; Koppert, Linetta B

    2016-08-01

    Prophylactic skin-sparing mastectomy (SSM) and nipple-sparing mastectomy (NSM) both are associated with major risk reduction in women with high breast cancer risk. Skin-sparing mastectomy followed by nipple-areola complex (NAC) reconstruction is standard of care, but NSM is increasingly being performed. Preservation of the NAC in NSM may increase patient satisfaction. Therefore, we measured NAC sensitivity after NSM and compared patient satisfaction as well as body image after SSM with NSM. Women who underwent prophylactic bilateral SSM or NSM and immediate implant breast reconstruction between 2002 and 2012 were eligible. Patient satisfaction was assessed using the Breast-Q reconstruction questionnaire, body image using Hopwood's body image scale (BIS), and satisfaction with the (reconstructed) NAC using a study-specific questionnaire. In the NSM group, NAC sensitivity was assessed using Semmes Weinstein monofilaments with a 5-point scale and compared with NAC sensitivity in a nonoperated control group. The SSM group comprised 25 women (50 SSMs) and the NSM group 20 women (39 NSMs). Median follow-up was 65 months in the SSM group compared with 27 months in the NSM group (P < 0.01). In univariable analyses, Breast-Q scores were favorable in the SSM group compared with the NSM group with trends for higher "satisfaction with breasts" (66.2 vs 56.6; P = 0.06) and "satisfaction with outcome" (76.1 vs 61.5; P = 0.09). Mean BIS score of 7.1/30 in the SSM group and 9.3/30 in the NSM group (P = 0.35). Adjusted for follow-up, there were no significant differences in Breast-Q scores, nor in BIS scores. Interestingly, satisfaction with the (reconstructed) NAC was similar after SSM and NSM. Nipple-areola complex sensitivity was lower in the NSM group (mean score, 1.9; 95% confidence interval, 1.5-2.3) compared with the control group (mean score, 4.7; 95% confidence interval, 4.6-4.9; P < 0.01). Breast-Q scores regarding satisfaction with breasts and overall outcome were in favor of the SSM group. Residual NAC sensitivity after NSM was low. This suggests that SSM followed by NAC reconstruction is a balanced alternative to NSM. We observed no significant differences in body image and NAC-specific satisfaction between the NSM and SSM groups.

  6. Enhanced DNA Sensing via Catalytic Aggregation of Gold Nanoparticles

    PubMed Central

    Huttanus, Herbert M.; Graugnard, Elton; Yurke, Bernard; Knowlton, William B.; Kuang, Wan; Hughes, William L.; Lee, Jeunghoon

    2014-01-01

    A catalytic colorimetric detection scheme that incorporates a DNA-based hybridization chain reaction into gold nanoparticles was designed and tested. While direct aggregation forms an inter-particle linkage from only ones target DNA strand, the catalytic aggregation forms multiple linkages from a single target DNA strand. Gold nanoparticles were functionalized with thiol-modified DNA strands capable of undergoing hybridization chain reactions. The changes in their absorption spectra were measured at different times and target concentrations and compared against direct aggregation. Catalytic aggregation showed a multifold increase in sensitivity at low target concentrations when compared to direct aggregation. Gel electrophoresis was performed to compare DNA hybridization reactions in catalytic and direct aggregation schemes, and the product formation was confirmed in the catalytic aggregation scheme at low levels of target concentrations. The catalytic aggregation scheme also showed high target specificity. This application of a DNA reaction network to gold nanoparticle-based colorimetric detection enables highly-sensitive, field-deployable, colorimetric readout systems capable of detecting a variety of biomolecules. PMID:23891867

  7. Quantitative assessment of serum-specific IgE in the diagnosis of human cystic echinococcosis.

    PubMed

    Marinova, I; Nikolov, G; Michova, A; Kurdova, R; Petrunov, B

    2011-07-01

    Anti-Echinococcus serum immunoglobulin (Ig)E was assessed by the ImmunoCAP system and compared with anti-Echinococcus serum IgG assessed by enzyme-linked immunosorbent assay (ELISA) and Western blot. The ImmunoCAP system revealed very high specificity (one false positive of 110 healthy individuals), low cross-reactivity (one false positive of 58 patients with other diseases) and decreased sensitivity (73.55%). Receiver operating characteristic analysis displayed a beneficial diagnostic value with high accuracy. Comparison of the ImmunoCAP system with ELISA and Western blot showed significantly higher specificity and significantly lower cross-reactivity compared with the ELISA. Examination of sera from 155 patients with cystic echinococcosis (CE) showed varying levels of anti-Echinococcus IgE (range, 0.01-118.33 kUA/L). However, most samples had moderately elevated IgE levels. Analysis of serum-specific IgE revealed significantly higher sensitivity of the ImmunoCAP system and significantly higher antibody levels in hepatic CE compared with pulmonary CE. © 2011 Blackwell Publishing Ltd.

  8. Role of "Sural Sparing" Pattern (Absent/Abnormal Median and Ulnar with Present Sural SNAP) Compared to Absent/Abnormal Median or Ulnar with Normal Sural SNAP in Acute Inflammatory Demyelinating Polyneuropathy.

    PubMed

    Surpur, Spurthi Sunil; Govindarajan, Raghav

    2017-01-01

    Sural sparing defined as absent/abnormal median sensory nerve action potential (SNAP) amplitude or absent/abnormal ulnar SNAP amplitude with a normal sural SNAP amplitude is thought to be a marker for inflammatory demyelinating polyneuropathies. If sural sparing pattern specifically defined as absent/abnormal median and ulnar SNAP amplitude with normal sural SNAP amplitude (AMUNS) is sensitive and specific when compared with either absent/abnormal median and normal sural (AMNS) or absent/abnormal ulnar and normal sural (AUNS) for acute inflammatory demyelinating polyneuropathy (AIDP), chronic inflammatory demyelinating polyneuropathy (CIDP), select non-diabetic axonopathies (AXPs), and diabetic neuropathies (DNs). Retrospective analysis from 2001 to 2010 on all newly diagnosed AIDP, CIDP, select non-diabetic AXP, and DN. There were 20 AIDP and 23 CIDP. Twenty AXP and 50 DN patients between 2009 and 2010 were included as controls. AMUNS was seen in 65% of AIDP, 39% CIDP compared with 10% of AXP and 6% for DN with sensitivity of 51%, specificity of 92%, whereas the specificity of AMNS/AUNS was 73% and its sensitivity was 58%. If a patient has AMUNS they are >12 times more likely to have AIDP ( p  < 0.001). Sural sparing is highly specific but not sensitive when compared with either AMNS or AUNS in AIDP but does not add to sensitivity or specificity in CIDP.

  9. Different Mutations Endowing Resistance to Acetyl-CoA Carboxylase Inhibitors Results in Changes in Ecological Fitness of Lolium rigidum Populations

    PubMed Central

    Matzrafi, Maor; Gerson, Ofri; Rubin, Baruch; Peleg, Zvi

    2017-01-01

    Various mutations altering the herbicide target site (TS), can lead to structural modifications that decrease binding efficiency and results in herbicide resistant weed. In most cases, such a mutation will be associated with ecological fitness penalty under herbicide free environmental conditions. Here we describe the effect of various mutations, endowing resistance to acetyl-CoA carboxylase (ACCase) inhibitors, on the ecological fitness penalty of Lolium rigidum populations. The TS resistant populations, MH (substitution of isoleucine 1781 to leucine) and NO (cysteine 2088 to arginine), were examined and compared to a sensitive population (AL). Grain weight (GW) characterization of individual plants from both MH and NO populations, showed that resistant individuals had significantly lower GW compared with sensitive ones. Under high temperatures, both TS resistant populations exhibited lower germination rate as compared with the sensitive (AL) population. Likewise, early vigor of plants from both TS resistant populations was significantly lower than the one measured in plants of the sensitive population. Under crop-weed intra-species competition, we found an opposite trend in the response of plants from different populations. Relatively to inter-population competition conditions, plants of MH population were less affected and presented higher reproduction abilities compared to plants from both AL and NO populations. On the basis of our results, a non-chemical approach can be taken to favor the sensitive individuals, eventually leading to a decline in resistant individuals in the population. PMID:28690621

  10. Radiation imaging with a new scintillator and a CMOS camera

    NASA Astrophysics Data System (ADS)

    Kurosawa, S.; Shoji, Y.; Pejchal, J.; Yokota, Y.; Yoshikawa, A.

    2014-07-01

    A new imaging system consisting of a high-sensitivity complementary metal-oxide semiconductor (CMOS) sensor, a microscope and a new scintillator, Ce-doped Gd3(Al,Ga)5O12 (Ce:GAGG) grown by the Czochralski process, has been developed. The noise, the dark current and the sensitivity of the CMOS camera (ORCA-Flash4.0, Hamamatsu) was revised and compared to a conventional CMOS, whose sensitivity is at the same level as that of a charge coupled device (CCD) camera. Without the scintillator, this system had a good position resolution of 2.1 ± 0.4 μm and we succeeded in obtaining the alpha-ray images using 1-mm thick Ce:GAGG crystal. This system can be applied for example to high energy X-ray beam profile monitor, etc.

  11. Magnetic particle imaging for radiation-free, sensitive and high-contrast vascular imaging and cell tracking.

    PubMed

    Zhou, Xinyi Y; Tay, Zhi Wei; Chandrasekharan, Prashant; Yu, Elaine Y; Hensley, Daniel W; Orendorff, Ryan; Jeffris, Kenneth E; Mai, David; Zheng, Bo; Goodwill, Patrick W; Conolly, Steven M

    2018-05-10

    Magnetic particle imaging (MPI) is an emerging ionizing radiation-free biomedical tracer imaging technique that directly images the intense magnetization of superparamagnetic iron oxide nanoparticles (SPIOs). MPI offers ideal image contrast because MPI shows zero signal from background tissues. Moreover, there is zero attenuation of the signal with depth in tissue, allowing for imaging deep inside the body quantitatively at any location. Recent work has demonstrated the potential of MPI for robust, sensitive vascular imaging and cell tracking with high contrast and dose-limited sensitivity comparable to nuclear medicine. To foster future applications in MPI, this new biomedical imaging field is welcoming researchers with expertise in imaging physics, magnetic nanoparticle synthesis and functionalization, nanoscale physics, and small animal imaging applications. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Studentized continuous wavelet transform (t-CWT) in the analysis of individual ERPs: real and simulated EEG data

    PubMed Central

    Real, Ruben G. L.; Kotchoubey, Boris; Kübler, Andrea

    2014-01-01

    This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings. PMID:25309308

  13. Studentized continuous wavelet transform (t-CWT) in the analysis of individual ERPs: real and simulated EEG data.

    PubMed

    Real, Ruben G L; Kotchoubey, Boris; Kübler, Andrea

    2014-01-01

    This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings.

  14. High-numerical-aperture-based virtual point detectors for photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Li, Changhui; Wang, Lihong V.

    2008-07-01

    The focal point of a high-numerical-aperture (NA) ultrasonic transducer can be used as a virtual point detector. This virtual point detector detects omnidirectionally over a wide acceptance angle. It also combines a large active transducer surface and a small effective virtual detector size. Thus the sensitivity is high compared with that of a real point detector, and the aperture effect is small compared with that of a finite size transducer. We present two kinds of high-NA-based virtual point detectors and their successful application in photoacoustic tomography. They can also be applied in other ultrasound-related fields.

  15. A behavioral audiogram of the red fox (Vulpes vulpes).

    PubMed

    Malkemper, E Pascal; Topinka, Václav; Burda, Hynek

    2015-02-01

    We determined the absolute hearing sensitivity of the red fox (Vulpes vulpes) using an adapted standard psychoacoustic procedure. The animals were tested in a reward-based go/no-go procedure in a semi-anechoic chamber. At 60 dB sound pressure level (SPL) (re 20 μPa) red foxes perceive pure tones between 51 Hz and 48 kHz, spanning 9.84 octaves with a single peak sensitivity of -15 dB at 4 kHz. The red foxes' high-frequency cutoff is comparable to that of the domestic dog while the low-frequency cutoff is comparable to that of the domestic cat and the absolute sensitivity is between both species. The maximal absolute sensitivity of the red fox is among the best found to date in any mammal. The procedure used here allows for assessment of animal auditory thresholds using positive reinforcement outside the laboratory. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. A novel and sensitive radioreceptor assay for serum melatonin levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tenn, C.; Niles, L.

    A simple and sensitive radioreceptor assay (RRA) has been developed to measure melatonin levels in serum. The assay is based on competition between 2-({sup 125}I)iodomelatonin (({sup 125}I)MEL) and melatonin for binding to high-affinity binding sites in chick forebrain. To measure the amount of melatonin present in a serum sample, it was extracted with dichloromethane and added to the assay medium. The percentage inhibition of radioligand binding in the presence of the extracted serum was determined and compared to the percent displacement by known amounts of melatonin in a standard curve. There was little or no cross-reactivity with other structurally relatedmore » compounds. The sensitivity of the assay is {approximately}1.5pg/0.15 mL and the intra- and inter-assay variations are approximately 8%. Since the RRA results are comparable to that of an established radioimmunoassay (RIA), it provides a sensitive and rapid alternative to the more time consuming RIA.« less

  17. Thick phase holographic gratings recorded on BB-640 and PFG-01 silver halide materials

    NASA Astrophysics Data System (ADS)

    Neipp, Cristian; Márquez, Andrés; Pascual, Inmaculada; Beléndez, Augusto

    2003-09-01

    Photographic emulsions are still widely used to record holographic optical elements. In particular, if high diffraction efficiencies are needed, phase volume holograms are preferably recorded on these emulsions. Two particular techniques producing high-quality volume phase holograms are fixation-free rehalogenating bleaching and the use of silver-halide-sensitized gelatin. In this work we compare these two particular techniques applied to three different red-sensitive emulsions: Agfa 8E75 HD, BB-640, and Slavich PFG-01 emulsions. The differences between these emulsions determine the particular experimental conditions needed to record high-quality volume holograms on them. In this work these differences are analysed, and also their influence on the experimental procedure.

  18. A novel lab-on-chip platform with integrated solid phase PCR and Supercritical Angle Fluorescence (SAF) microlens array for highly sensitive and multiplexed pathogen detection.

    PubMed

    Hung, Tran Quang; Chin, Wai Hoe; Sun, Yi; Wolff, Anders; Bang, Dang Duong

    2017-04-15

    Solid-phase PCR (SP-PCR) has become increasingly popular for molecular diagnosis and there have been a few attempts to incorporate SP-PCR into lab-on-a-chip (LOC) devices. However, their applicability for on-line diagnosis is hindered by the lack of sensitive and portable on-chip optical detection technology. In this paper, we addressed this challenge by combining the SP-PCR with super critical angle fluorescence (SAF) microlens array embedded in a microchip. We fabricated miniaturized SAF microlens array as part of a microfluidic chamber in thermoplastic material and performed multiplexed SP-PCR directly on top of the SAF microlens array. Attribute to the high fluorescence collection efficiency of the SAF microlens array, the SP-PCR assay on the LOC platform demonstrated a high sensitivity of 1.6 copies/µL, comparable to off-chip detection using conventional laser scanner. The combination of SP-PCR and SAF microlens array allows for on-chip highly sensitive and multiplexed pathogen detection with low-cost and compact optical components. The LOC platform would be widely used as a high-throughput biosensor to analyze food, clinical and environmental samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A 3D Chemically Modified Graphene Hydrogel for Fast, Highly Sensitive, and Selective Gas Sensor.

    PubMed

    Wu, Jin; Tao, Kai; Guo, Yuanyuan; Li, Zhong; Wang, Xiaotian; Luo, Zhongzhen; Feng, Shuanglong; Du, Chunlei; Chen, Di; Miao, Jianmin; Norford, Leslie K

    2017-03-01

    Reduced graphene oxide (RGO) has proved to be a promising candidate in high-performance gas sensing in ambient conditions. However, trace detection of different kinds of gases with simultaneously high sensitivity and selectivity is challenging. Here, a chemiresistor-type sensor based on 3D sulfonated RGO hydrogel (S-RGOH) is reported, which can detect a variety of important gases with high sensitivity, boosted selectivity, fast response, and good reversibility. The NaHSO 3 functionalized RGOH displays remarkable 118.6 and 58.9 times higher responses to NO 2 and NH 3 , respectively, compared with its unmodified RGOH counterpart. In addition, the S-RGOH sensor is highly responsive to volatile organic compounds. More importantly, the characteristic patterns on the linearly fitted response-temperature curves are employed to distinguish various gases for the first time. The temperature of the sensor is elevated rapidly by an imbedded microheater with little power consumption. The 3D S-RGOH is characterized and the sensing mechanisms are proposed. This work gains new insights into boosting the sensitivity of detecting various gases by combining chemical modification and 3D structural engineering of RGO, and improving the selectivity of gas sensing by employing temperature dependent response characteristics of RGO for different gases.

  20. Correlation between Preoperative High Resolution Computed Tomography (CT) Findings with Surgical Findings in Chronic Otitis Media (COM) Squamosal Type.

    PubMed

    Karki, S; Pokharel, M; Suwal, S; Poudel, R

    Background The exact role of High resolution computed tomography (HRCT) temporal bone in preoperative assessment of Chronic suppurative otitis media atticoantral disease still remains controversial. Objective To evaluate the role of high resolution computed tomography temporal bone in Chronic suppurative otitis media atticoantral disease and to compare preoperative computed tomographic findings with intra-operative findings. Method Prospective, analytical study conducted among 65 patients with chronic suppurative otitis media atticoantral disease in Department of Radiodiagnosis, Kathmandu University Dhulikhel Hospital between January 2015 to July 2016. The operative findings were compared with results of imaging. The parameters of comparison were erosion of ossicles, scutum, facial canal, lateral semicircular canal, sigmoid and tegmen plate along with extension of disease to sinus tympani and facial recess. Sensitivity, specificity, negative predictive value, positive predictive values were calculated. Result High resolution computed tomography temporal bone offered sensitivity (Se) and specificity (Sp) of 100% for visualization of sigmoid and tegmen plate erosion. The performance of HRCT in detecting malleus (Se=100%, Sp=95.23%), incus (Se=100%,Sp=80.48%) and stapes (Se=96.55%, Sp=71.42%) erosion was excellent. It offered precise information about facial canal erosion (Se=100%, Sp=75%), scutum erosion (Se=100%, Sp=96.87%) and extension of disease to facial recess and sinus tympani (Se=83.33%,Sp=100%). high resolution computed tomography showed specificity of 100% for lateral semicircular canal erosion (Sp=100%) but with low sensitivity (Se=53.84%). Conclusion The findings of high resolution computed tomography and intra-operative findings were well comparable except for lateral semicircular canal erosion. high resolution computed tomography temporal bone acts as a road map for surgeon to identify the extent of disease, plan for appropriate procedure that is required and prepare for potential complications that can be encountered during surgery.

  1. Accuracy and Cost-Effectiveness of Cervical Cancer Screening by High-Risk HPV DNA Testing of Self-Collected Vaginal Samples

    PubMed Central

    Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.

    2010-01-01

    Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553

  2. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys

    PubMed Central

    Hass, Charles A.; Angueyra, Juan M.; Lindbloom-Brown, Zachary; Rieke, Fred; Horwitz, Gregory D.

    2015-01-01

    Chromatic sensitivity cannot exceed limits set by noise in the cone photoreceptors. To determine how close neurophysiological and psychophysical chromatic sensitivity come to these limits, we developed a parameter-free model of stimulus encoding in the cone outer segments, and we compared the sensitivity of the model to the psychophysical sensitivity of monkeys performing a detection task and to the sensitivity of individual V1 neurons. Modeled cones had a temporal impulse response and a noise power spectrum that were derived from in vitro recordings of macaque cones, and V1 recordings were made during performance of the detection task. The sensitivity of the simulated cone mosaic, the V1 neurons, and the monkeys were tightly yoked for low-spatiotemporal-frequency isoluminant modulations, indicating high-fidelity signal transmission for this class of stimuli. Under the conditions of our experiments and the assumptions for our model, the signal-to-noise ratio for these stimuli dropped by a factor of ∼3 between the cones and perception. Populations of weakly correlated V1 neurons narrowly exceeded the monkeys' chromatic sensitivity but fell well short of the cones' chromatic sensitivity, suggesting that most of the behavior-limiting noise lies between the cone outer segments and the output of V1. The sensitivity gap between the cones and behavior for achromatic stimuli was larger than for chromatic stimuli, indicating greater postreceptoral noise. The cone mosaic model provides a means to compare visual sensitivity across disparate stimuli and to identify sources of noise that limit visual sensitivity. PMID:26523737

  3. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys.

    PubMed

    Hass, Charles A; Angueyra, Juan M; Lindbloom-Brown, Zachary; Rieke, Fred; Horwitz, Gregory D

    2015-01-01

    Chromatic sensitivity cannot exceed limits set by noise in the cone photoreceptors. To determine how close neurophysiological and psychophysical chromatic sensitivity come to these limits, we developed a parameter-free model of stimulus encoding in the cone outer segments, and we compared the sensitivity of the model to the psychophysical sensitivity of monkeys performing a detection task and to the sensitivity of individual V1 neurons. Modeled cones had a temporal impulse response and a noise power spectrum that were derived from in vitro recordings of macaque cones, and V1 recordings were made during performance of the detection task. The sensitivity of the simulated cone mosaic, the V1 neurons, and the monkeys were tightly yoked for low-spatiotemporal-frequency isoluminant modulations, indicating high-fidelity signal transmission for this class of stimuli. Under the conditions of our experiments and the assumptions for our model, the signal-to-noise ratio for these stimuli dropped by a factor of ∼3 between the cones and perception. Populations of weakly correlated V1 neurons narrowly exceeded the monkeys' chromatic sensitivity but fell well short of the cones' chromatic sensitivity, suggesting that most of the behavior-limiting noise lies between the cone outer segments and the output of V1. The sensitivity gap between the cones and behavior for achromatic stimuli was larger than for chromatic stimuli, indicating greater postreceptoral noise. The cone mosaic model provides a means to compare visual sensitivity across disparate stimuli and to identify sources of noise that limit visual sensitivity.

  4. Broadband sensitized photon up-conversion at subsolar irradiance (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pedrini, Jacopo; Monguzzi, Angelo; Meinardi, Francesco

    2016-09-01

    A crucial limit of solar devices is their inability to harvest the full solar spectrum. Currently, sensitized up-conversion based on triplet-tripled annihilation (STTA-UC) in bi-component organic systems is the most promising technique to recover sub-bandgap photons, showing good efficiencies also at excitation intensities comparable to the solar irradiance. In STTA-UC, high-energy light is generated through annihilation of metastable triplet states of molecules acting as emitters, which are populated via resonant energy transfer from a light-harvesting sensitizer. However, suitable sensitizers show narrow absorption bands, limiting the fraction of recoverable photons, therefore preventing the application of STTA-UC to real-world devices. Here we demonstrate how to overcome the described limit by using multiple sensitizers that work cooperatively to broaden the overall system absorption band. This is obtained using an additional sensitizer that transfers the extra harvested energy to the main one (sensitization of the sensitizer), or a set of properly designed complementary absorbing sensitizers all able to excite simultaneously the same emitter (multi-sensitizers). In both cases STTA-UC performances result strongly enhanced compared to the corresponding mono-sensitizer system, increasing the up-converted light intensity generated at AM 1.5 up to two times. Remarkably, by coupling our light converters to a DSSC we prove its operation by exploiting exclusively sub-bandgap photons. A detailed modeling of the photophysical processes involved in these complex systems allows us to draw the guidelines for the design of the next generation STTA-UC materials, encouraging their application to photovoltaic technologies.

  5. Effect of verapamil on bronchial goblet cells of asthma: an experimental study on sensitized animals.

    PubMed

    Khakzad, Mohammad Reza; Mirsadraee, Majid; Mohammadpour, Amirhooshang; Ghafarzadegan, Kamram; Hadi, Raziye; Saghari, Mahdiye; Meshkat, Mojtaba

    2012-04-01

    Goblet cell hyperplasia (GCH) and mucus hypersecretion in the airway is recognized as an important contributor to morbidity and mortality in asthma and COPD. Verapamil is a calcium channel blocker that binds to the alpha-subunit of L-type calcium channels and inhibits the mucin gene via the calmodulin and CaM kinase pathway. The objective of this study was to determine the in vivo effect of verapamil on GCH and eosinophilic inflammation in sensitized mice. Male BALB/c mice were sensitized to ovalbumin using the standard method. Two groups of animals were received verapamil via an intramuscular injection: 1-low dose (0.5 mg/kg/day for two weeks), 2-high dose (1.5 mg/kg/day for two weeks). Serum and bronchoalveolar lavage fluid (BALF) was collected and analyzed for inflammatory cells, interferon-γ and IL-4. The left lung was sent for histopathological evaluation, especially for periodic acid-Schiff (PAS), to identify goblet cells in the epithelium. The degree of inflammatory cell infiltration, including eosinophils, mucus plugging, and smooth muscle thickness of the airways were classified on a semi quantitative scale. Inflammatory cell infiltration in peribronchial and perivascular areas was observed in all sensitized groups. Eosinophils percentage in the BALF significantly decreased in verapamil-treated mice compared with sensitized mice (from 19.8% in asthmatic to 5.4% for low dose and 4.4% for high dose). The ratio of airway goblet cells per epithelial cells were significantly lower in verapamil-treated mice versus sensitized mice (1.57±1.30% for low dose; 1.50±0.93% for high dose versus 12.93±7.55%, P<0.05, respectively). Mucus production of goblet cells decreased significantly in verapamil-treated mice versus sensitized mice (mean score was 1.45±0.30 for low dose; 0.81±1.00 for high dose versus 2.85±0.86 in the sensitized control group, P<0.05, respectively). The concentration of serum and BALF-IFN-γ in verapamil-treated mice markedly increased by the verapamil treatment when compared to sensitized mice (15.1±0.43 versus 4.7±0.96, P<0.05 and 91.8±47.7 versus 14.8±4.6, P<0.01, respectively). Verapamil is a useful drug with therapeutic targeting on GCH and a potential way to limit mucous production and improve bronchial inflammation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. A single bout of high-intensity interval exercise and work-matched moderate-intensity exercise has minimal effect on glucose tolerance and insulin sensitivity in 7- to 10-year-old boys.

    PubMed

    Cockcroft, Emma J; Williams, Craig A; Jackman, Sarah R; Bassi, Shikhar; Armstrong, Neil; Barker, Alan R

    2018-01-01

    The purpose of this study was to assess the acute effect of high-intensity interval exercise (HIIE) and moderate-intensity exercise (MIE) on glucose tolerance, insulin sensitivity and fat oxidation in young boys. Eleven boys (8.8 ± 0.8 y) completed three conditions: 1) HIIE; 2) work-matched MIE; and 3) rest (CON) followed by an oral glucose tolerance test (OGTT) to determine glucose tolerance and insulin sensitivity (Cederholm index). Fat oxidation was measured following the OGTT using indirect calorimetry. There was no effect for condition on plasma [glucose] and [insulin] area under the curve (AUC) responses following the OGTT (P > 0.09). However, there was a "trend" for a condition effect for insulin sensitivity with a small increase after HIIE (P = 0.04, ES = 0.28, 9.7%) and MIE (P = 0.07, ES = 0.21, 6.5%) compared to CON. There was an increase in fat oxidation AUC following HIIE (P = 0.008, ES = 0.79, 38.9%) compared to CON, but with no differences between MIE and CON and HIIE and MIE (P > 0.13). In conclusion, 7- to 10-year-old boys may have limited scope to improve insulin sensitivity and glucose tolerance after a single bout of HIIE and MIE. However, fat oxidation is augmented after HIIE but not MIE.

  7. High-sensitivity brain SPECT system using cadmium telluride (CdTe) semiconductor detector and 4-pixel matched collimator.

    PubMed

    Suzuki, Atsuro; Takeuchi, Wataru; Ishitsu, Takafumi; Tsuchiya, Katsutoshi; Morimoto, Yuichi; Ueno, Yuichiro; Kobashi, Keiji; Kubo, Naoki; Shiga, Tohru; Tamaki, Nagara

    2013-11-07

    For high-sensitivity brain imaging, we have developed a two-head single-photon emission computed tomography (SPECT) system using a CdTe semiconductor detector and 4-pixel matched collimator (4-PMC). The term, '4-PMC' indicates that the collimator hole size is matched to a 2 × 2 array of detector pixels. By contrast, a 1-pixel matched collimator (1-PMC) is defined as a collimator whose hole size is matched to one detector pixel. The performance of the higher-sensitivity 4-PMC was experimentally compared with that of the 1-PMC. The sensitivities of the 1-PMC and 4-PMC were 70 cps/MBq/head and 220 cps/MBq/head, respectively. The SPECT system using the 4-PMC provides superior image resolution in cold and hot rods phantom with the same activity and scan time to that of the 1-PMC. In addition, with half the usual scan time the 4-PMC provides comparable image quality to that of the 1-PMC. Furthermore, (99m)Tc-ECD brain perfusion images of healthy volunteers obtained using the 4-PMC demonstrated acceptable image quality for clinical diagnosis. In conclusion, our CdTe SPECT system equipped with the higher-sensitivity 4-PMC can provide better spatial resolution than the 1-PMC either in half the imaging time with the same administered activity, or alternatively, in the same imaging time with half the activity.

  8. Beware the black box: investigating the sensitivity of FEA simulations to modelling factors in comparative biomechanics.

    PubMed

    Walmsley, Christopher W; McCurry, Matthew R; Clausen, Phillip D; McHenry, Colin R

    2013-01-01

    Finite element analysis (FEA) is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be 'reasonable' are often assumed to have little influence on the results and their interpretation. HERE WE REPORT AN EXTENSIVE SENSITIVITY ANALYSIS WHERE HIGH RESOLUTION FINITE ELEMENT (FE) MODELS OF MANDIBLES FROM SEVEN SPECIES OF CROCODILE WERE ANALYSED UNDER LOADS TYPICAL FOR COMPARATIVE ANALYSIS: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous), scaling (standardising volume, surface area, or length), tooth position (front, mid, or back tooth engagement), and linear load case (type of loading for each feeding type). Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different comparative datasets would also be sensitive to identical simulation assumptions; hence, modelling assumptions should undergo rigorous selection. The accuracy of input data is paramount, and simulations should focus on taking biological context into account. Ideally, validation of simulations should be addressed; however, where validation is impossible or unfeasible, sensitivity analyses should be performed to identify which assumptions have the greatest influence upon the results.

  9. Beware the black box: investigating the sensitivity of FEA simulations to modelling factors in comparative biomechanics

    PubMed Central

    McCurry, Matthew R.; Clausen, Phillip D.; McHenry, Colin R.

    2013-01-01

    Finite element analysis (FEA) is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be ‘reasonable’ are often assumed to have little influence on the results and their interpretation. Here we report an extensive sensitivity analysis where high resolution finite element (FE) models of mandibles from seven species of crocodile were analysed under loads typical for comparative analysis: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous), scaling (standardising volume, surface area, or length), tooth position (front, mid, or back tooth engagement), and linear load case (type of loading for each feeding type). Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different comparative datasets would also be sensitive to identical simulation assumptions; hence, modelling assumptions should undergo rigorous selection. The accuracy of input data is paramount, and simulations should focus on taking biological context into account. Ideally, validation of simulations should be addressed; however, where validation is impossible or unfeasible, sensitivity analyses should be performed to identify which assumptions have the greatest influence upon the results. PMID:24255817

  10. Chinese nurses' perceived barriers and facilitators of ethical sensitivity.

    PubMed

    Huang, Fei Fei; Yang, Qing; Zhang, Jie; Khoshnood, Kaveh; Zhang, Jing Ping

    2016-08-01

    An overview of ethical sensitivity among Chinese registered nurses is needed to develop and optimize the education programs and interventions to cultivate and improve ethical sensitivity. The study was conducted to explore the barriers to and facilitators of ethical sensitivity among Chinese registered nurses working in hospital settings. A convergent parallel mixed-methods research design was adopted. In the cross-sectional quantitative study, the Chinese Moral Sensitivity Questionnaire-revised version was used to assess the levels of ethical sensitivity among registered nurses, and the scores were correlated with key demographics, training experiences in ethics, and workplace cultural environments (n = 306). In the qualitative study, semi-structured interviews were used to elicit the nurses' perceptions of the barriers and facilitators in nurturing ethical sensitivity (n = 15). The data were collected from February to June 2014. This study was approved by the Institutional Review Boards of Yale University and Central South University. Despite moderately high overall Chinese Moral Sensitivity Questionnaire-revised version scores, the ethical sensitivity among Chinese nurses lags in practice. Barriers to ethical sensitivity include the lack of knowledge related to ethics, lack of working experience as a nurse, the hierarchical organizational climate, and the conformist working attitude. The positive workplace cultural environments and application of ethical knowledge in practice were considered potential facilitators of ethical sensitivity. The findings of this study were compared with studies from other countries to examine the barriers and facilitators of ethical sensitivity in Chinese nurses. This mixed-methods study showed that even though the Chinese nurses have moderately high sensitivity to the ethical issues encountered in hospitals, there is still room for improvement. The barriers to and facilitators of ethical sensitivity identified here offer new and important strategies to support and enhance the nurses' sensitivity to ethical issues. © The Author(s) 2015.

  11. Multiplexed transcriptome analysis to detect ALK, ROS1 and RET rearrangements in lung cancer

    PubMed Central

    Rogers, Toni-Maree; Arnau, Gisela Mir; Ryland, Georgina L.; Huang, Stephen; Lira, Maruja E.; Emmanuel, Yvette; Perez, Omar D.; Irwin, Darryl; Fellowes, Andrew P.; Wong, Stephen Q.; Fox, Stephen B.

    2017-01-01

    ALK, ROS1 and RET gene fusions are important predictive biomarkers for tyrosine kinase inhibitors in lung cancer. Currently, the gold standard method for gene fusion detection is Fluorescence In Situ Hybridization (FISH) and while highly sensitive and specific, it is also labour intensive, subjective in analysis, and unable to screen a large numbers of gene fusions. Recent developments in high-throughput transcriptome-based methods may provide a suitable alternative to FISH as they are compatible with multiplexing and diagnostic workflows. However, the concordance between these different methods compared with FISH has not been evaluated. In this study we compared the results from three transcriptome-based platforms (Nanostring Elements, Agena LungFusion panel and ThermoFisher NGS fusion panel) to those obtained from ALK, ROS1 and RET FISH on 51 clinical specimens. Overall agreement of results ranged from 86–96% depending on the platform used. While all platforms were highly sensitive, both the Agena panel and Thermo Fisher NGS fusion panel reported minor fusions that were not detectable by FISH. Our proof–of–principle study illustrates that transcriptome-based analyses are sensitive and robust methods for detecting actionable gene fusions in lung cancer and could provide a robust alternative to FISH testing in the diagnostic setting. PMID:28181564

  12. G-Channel Restoration for RWB CFA with Double-Exposed W Channel

    PubMed Central

    Park, Chulhee; Song, Ki Sun; Kang, Moon Gi

    2017-01-01

    In this paper, we propose a green (G)-channel restoration for a red–white–blue (RWB) color filter array (CFA) image sensor using the dual sampling technique. By using white (W) pixels instead of G pixels, the RWB CFA provides high-sensitivity imaging and an improved signal-to-noise ratio compared to the Bayer CFA. However, owing to this high sensitivity, the W pixel values become rapidly over-saturated before the red–blue (RB) pixel values reach the appropriate levels. Because the missing G color information included in the W channel cannot be restored with a saturated W, multiple captures with dual sampling are necessary to solve this early W-pixel saturation problem. Each W pixel has a different exposure time when compared to those of the R and B pixels, because the W pixels are double-exposed. Therefore, a RWB-to-RGB color conversion method is required in order to restore the G color information, using a double-exposed W channel. The proposed G-channel restoration algorithm restores G color information from the W channel by considering the energy difference caused by the different exposure times. Using the proposed method, the RGB full-color image can be obtained while maintaining the high-sensitivity characteristic of the W pixels. PMID:28165425

  13. G-Channel Restoration for RWB CFA with Double-Exposed W Channel.

    PubMed

    Park, Chulhee; Song, Ki Sun; Kang, Moon Gi

    2017-02-05

    In this paper, we propose a green (G)-channel restoration for a red-white-blue (RWB) color filter array (CFA) image sensor using the dual sampling technique. By using white (W) pixels instead of G pixels, the RWB CFA provides high-sensitivity imaging and an improved signal-to-noise ratio compared to the Bayer CFA. However, owing to this high sensitivity, the W pixel values become rapidly over-saturated before the red-blue (RB) pixel values reach the appropriate levels. Because the missing G color information included in the W channel cannot be restored with a saturated W, multiple captures with dual sampling are necessary to solve this early W-pixel saturation problem. Each W pixel has a different exposure time when compared to those of the R and B pixels, because the W pixels are double-exposed. Therefore, a RWB-to-RGB color conversion method is required in order to restore the G color information, using a double-exposed W channel. The proposed G-channel restoration algorithm restores G color information from the W channel by considering the energy difference caused by the different exposure times. Using the proposed method, the RGB full-color image can be obtained while maintaining the high-sensitivity characteristic of the W pixels.

  14. Chemokines additional to IFN-γ can be used to differentiate among Mycobacterium tuberculosis infection possibilities and provide evidence of an early clearance phenotype.

    PubMed

    Nonghanphithak, Ditthawat; Reechaipichitkul, Wipa; Namwat, Wises; Naranbhai, Vivek; Faksri, Kiatichai

    2017-07-01

    Current diagnostic tests for tuberculosis (TB) remain limited in their ability to discriminate between active TB (ATB) and latent TB infection (LTBI). Early clearance (EC) of TB by individuals exposed to Mycobacterium tuberculosis is a debated phenomenon for which evidence is lacking. We measured and compared secreted chemokines in the plasma fraction from 48 ATB, 38 LTBI, 162 presumed EC and 39 healthy controls (HC) using the QuantiFERON ® -TB Gold In-Tube assay. Single chemokine markers were limited in their ability to discriminate between ATB and LTBI: IFN-γ showed 16.7% sensitivity; CCL2 showed moderate sensitivity (70.8%) and specificity (74.4%); CXCL10 showed high sensitivity (87.5%) and specificity (78.9%). Compared to IFN-γ alone, IFN-γ combined with CXCL10 significantly improved (p < 0.001) the sensitivity and specificity to discriminate between ATB and HC (97.9% sensitivity and 94.9% specificity) and between ATB and LTBI (89.6% sensitivity and 71.1% specificity). Levels of CCL2 were very significantly lower (p < 0.0001) in EC compared to HC groups and hence CCL2 is a useful marker for EC. This study demonstrated the potential application of profiling using multiple chemokines for differentiating among the various M. tuberculosis infection possibilities. We also present evidence to support the EC phenomenon based on the decrease of CCL2 levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Effects of resistance training on insulin sensitivity in overweight Latino adolescent males.

    PubMed

    Shaibi, Gabriel Q; Cruz, Martha L; Ball, Geoff D C; Weigensberg, Marc J; Salem, George J; Crespo, Noe C; Goran, Michael I

    2006-07-01

    Insulin resistance is thought to be a core defect in the pathophysiology of obesity-related comorbidities in children, such as type 2 diabetes. Exercise training is known to improve insulin resistance and reduce the risk of type 2 diabetes in adults. However, very little is known regarding the effects of exercise on insulin resistance in youth. Therefore, we examined the effects of a 16-wk resistance training exercise intervention on insulin sensitivity in youth at high risk for developing type 2 diabetes. Twenty-two overweight Latino adolescent males were randomly assigned to either a twice-per-week resistance training group (RT=11) or a nonexercising control group (C=11) for 16 wk. Strength was assessed by one-repetition maximum, body composition was quantified by dual-energy x-ray absorptiometry, and insulin sensitivity was determined by the frequently sampled intravenous glucose tolerance test with minimal modeling. Significant increases in upper- and lower-body strength were observed in the RT compared with the C group. The RT group significantly increased insulin sensitivity compared with the C group (P<0.05), and this increase remained significant after adjustment for changes in total fat mass and total lean tissue mass (P<0.05). Compared with baseline values, insulin sensitivity increased 45.1+/-7.3% in the RT group versus -0.9+/-12.9% in controls (P<0.01). A twice-per-week 16-wk resistance training program can significantly increase insulin sensitivity in overweight Latino adolescent males independent of changes in body composition.

  16. Cavity-enhanced resonant photoacoustic spectroscopy with optical feedback cw diode lasers: A novel technique for ultratrace gas analysis and high-resolution spectroscopy.

    PubMed

    Hippler, Michael; Mohr, Christian; Keen, Katherine A; McNaghten, Edward D

    2010-07-28

    Cavity-enhanced resonant photoacoustic spectroscopy with optical feedback cw diode lasers (OF-CERPAS) is introduced as a novel technique for ultratrace gas analysis and high-resolution spectroscopy. In the scheme, a single-mode cw diode laser (3 mW, 635 nm) is coupled into a high-finesse linear cavity and stabilized to the cavity by optical feedback. Inside the cavity, a build-up of laser power to at least 2.5 W occurs. Absorbing gas phase species inside the cavity are detected with high sensitivity by the photoacoustic effect using a microphone embedded in the cavity. To increase sensitivity further, coupling into the cavity is modulated at a frequency corresponding to a longitudinal resonance of an organ pipe acoustic resonator (f=1.35 kHz and Q approximately 10). The technique has been characterized by measuring very weak water overtone transitions near 635 nm. Normalized noise-equivalent absorption coefficients are determined as alpha approximately 4.4x10(-9) cm(-1) s(1/2) (1 s integration time) and 2.6x10(-11) cm(-1) s(1/2) W (1 s integration time and 1 W laser power). These sensitivities compare favorably with existing state-of-the-art techniques. As an advantage, OF-CERPAS is a "zero-background" method which increases selectivity and sensitivity, and its sensitivity scales with laser power.

  17. Comparison of standard- and nano-flow liquid chromatography platforms for MRM-based quantitation of putative plasma biomarker proteins.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Domanski, Dominik; Borchers, Christoph H

    2012-09-01

    The analytical performance of a standard-flow ultra-high-performance liquid chromatography (UHPLC) and a nano-flow high-performance liquid chromatography (HPLC) system, interfaced to the same state-of-the-art triple-quadrupole mass spectrometer, were compared for the multiple reaction monitoring (MRM)-mass spectrometry (MS)-based quantitation of a panel of 48 high-to-moderate-abundance cardiovascular disease-related plasma proteins. After optimization of the MRM transitions for sensitivity and testing for chemical interference, the optimum sensitivity, loading capacity, gradient, and retention-time reproducibilities were determined. We previously demonstrated the increased robustness of the standard-flow platform, but we expected that the standard-flow platform would have an overall lower sensitivity. This study was designed to determine if this decreased sensitivity could be compensated for by increased sample loading. Significantly fewer interferences with the MRM transitions were found for the standard-flow platform than for the nano-flow platform (2 out of 103 transitions compared with 42 out of 103 transitions, respectively), which demonstrates the importance of interference-testing when nano-flow systems are used. Using only interference-free transitions, 36 replicate LC/MRM-MS analyses resulted in equal signal reproducibilities between the two platforms (9.3 % coefficient of variation (CV) for 88 peptide targets), with superior retention-time precision for the standard-flow platform (0.13 vs. 6.1 % CV). Surprisingly, for 41 of the 81 proteotypic peptides in the final assay, the standard-flow platform was more sensitive while for 9 of 81 the nano-flow platform was more sensitive. For these 81 peptides, there was a good correlation between the two sets of results (R(2) = 0.98, slope = 0.97). Overall, the standard-flow platform had superior performance metrics for most peptides, and is a good choice if sufficient sample is available.

  18. Sensitivity and specificity of antibodies against HPV16 E6 and other early proteins for the detection of HPV16-driven oropharyngeal squamous cell carcinoma.

    PubMed

    Holzinger, Dana; Wichmann, Gunnar; Baboci, Lorena; Michel, Angelika; Höfler, Daniela; Wiesenfarth, Manuel; Schroeder, Lea; Boscolo-Rizzo, Paolo; Herold-Mende, Christel; Dyckhoff, Gerhard; Boehm, Andreas; Del Mistro, Annarosa; Bosch, Franz X; Dietz, Andreas; Pawlita, Michael; Waterboer, Tim

    2017-06-15

    To determine the sensitivity and specificity of HPV16 serology as diagnostic marker for HPV16-driven oropharyngeal squamous cell carcinoma (OPSCC), 214 HNSCC patients from Germany and Italy with fresh-frozen tumor tissues and sera collected before treatment were included in this study. Hundred and twenty cancer cases were from the oropharynx and 94 were from head and neck cancer regions outside the oropharynx (45 oral cavity, 12 hypopharynx and 35 larynx). Serum antibodies to early (E1, E2, E6 and E7) and late (L1) HPV16 proteins were analyzed by multiplex serology and were compared to tumor HPV RNA status as the gold standard. A tumor was defined as HPV-driven in the presence of HPV16 DNA and HPV16 transformation-specific RNA transcript patterns (E6*I, E1 ∧ E4 and E1C). Of 120 OPSCC, 66 (55%) were HPV16-driven. HPV16 E6 seropositivity was the best predictor of HPV16-driven OPSCC (diagnostic accuracy 97% [95%CI 92-99%], Cohen's kappa 0.93 [95%CI 0.8-1.0]). Of the 66 HPV-driven OPSCC, 63 were HPV16 E6 seropositive, compared to only one (1.8%) among the 54 non-HPV-driven OPSCC, resulting in a sensitivity of 96% (95%CI 88-98) and a specificity of 98% (95%CI 90-100). Of 94 HNSCC outside the oropharynx, six (6%) were HPV16-driven. In these patients, HPV16 E6 seropositivity had lower sensitivity (50%, 95%CI 19-81), but was highly specific (100%, 95%CI 96-100). In conclusion, HPV16 E6 seropositivity appears to be a highly reliable diagnostic marker for HPV16-driven OPSCC with very high sensitivity and specificity, but might be less sensitive for HPV16-driven HNSCC outside the oropharynx. © 2017 UICC.

  19. Evaluation of high throughput gene expression platforms using a genomic biomarker signature for prediction of skin sensitization.

    PubMed

    Forreryd, Andy; Johansson, Henrik; Albrekt, Ann-Sofie; Lindstedt, Malin

    2014-05-16

    Allergic contact dermatitis (ACD) develops upon exposure to certain chemical compounds termed skin sensitizers. To reduce the occurrence of skin sensitizers, chemicals are regularly screened for their capacity to induce sensitization. The recently developed Genomic Allergen Rapid Detection (GARD) assay is an in vitro alternative to animal testing for identification of skin sensitizers, classifying chemicals by evaluating transcriptional levels of a genomic biomarker signature. During assay development and biomarker identification, genome-wide expression analysis was applied using microarrays covering approximately 30,000 transcripts. However, the microarray platform suffers from drawbacks in terms of low sample throughput, high cost per sample and time consuming protocols and is a limiting factor for adaption of GARD into a routine assay for screening of potential sensitizers. With the purpose to simplify assay procedures, improve technical parameters and increase sample throughput, we assessed the performance of three high throughput gene expression platforms--nCounter®, BioMark HD™ and OpenArray®--and correlated their performance metrics against our previously generated microarray data. We measured the levels of 30 transcripts from the GARD biomarker signature across 48 samples. Detection sensitivity, reproducibility, correlations and overall structure of gene expression measurements were compared across platforms. Gene expression data from all of the evaluated platforms could be used to classify most of the sensitizers from non-sensitizers in the GARD assay. Results also showed high data quality and acceptable reproducibility for all platforms but only medium to poor correlations of expression measurements across platforms. In addition, evaluated platforms were superior to the microarray platform in terms of cost efficiency, simplicity of protocols and sample throughput. We evaluated the performance of three non-array based platforms using a limited set of transcripts from the GARD biomarker signature. We demonstrated that it was possible to achieve acceptable discriminatory power in terms of separation between sensitizers and non-sensitizers in the GARD assay while reducing assay costs, simplify assay procedures and increase sample throughput by using an alternative platform, providing a first step towards the goal to prepare GARD for formal validation and adaption of the assay for industrial screening of potential sensitizers.

  20. Geometrically confined ultrasmall gadolinium oxide nanoparticles boost the T1 contrast ability

    NASA Astrophysics Data System (ADS)

    Ni, Kaiyuan; Zhao, Zhenghuan; Zhang, Zongjun; Zhou, Zijian; Yang, Li; Wang, Lirong; Ai, Hua; Gao, Jinhao

    2016-02-01

    High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis.High-performance magnetic resonance imaging (MRI) contrast agents and novel contrast enhancement strategies are urgently needed for sensitive and accurate diagnosis. Here we report a strategy to construct a new T1 contrast agent based on the Solomon-Bloembergen-Morgan (SBM) theory. We loaded the ultrasmall gadolinium oxide nanoparticles into worm-like interior channels of mesoporous silica nanospheres (Gd2O3@MSN nanocomposites). This unique structure endows the nanocomposites with geometrical confinement, high molecular tumbling time, and a large coordinated number of water molecules, which results in a significant enhancement of the T1 contrast with longitudinal proton relaxivity (r1) as high as 45.08 mM-1 s-1. Such a high r1 value of Gd2O3@MSN, compared to those of ultrasmall Gd2O3 nanoparticles and gadolinium-based clinical contrast agents, is mainly attributed to the strong geometrical confinement effect. This strategy provides new guidance for developing various high-performance T1 contrast agents for sensitive imaging and disease diagnosis. Electronic supplementary information (ESI) available: Supplementary Fig. S1-S6. See DOI: 10.1039/c5nr08402d

  1. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Laser microphotoacoustic sensor of ammonia traces in the atmosphere

    NASA Astrophysics Data System (ADS)

    Serebryakov, D. V.; Morozov, I. V.; Kosterev, A. A.; Letokhov, V. S.

    2010-02-01

    A microphotoacoustic highly selective sensor of ammonia is built. Main attention is paid to the operation mechanism of the acoustic sensor based on a quartz tuning fork. The optimal dimensions and configuration of the acoustic resonator are determined, which made it possible to increase the sensor sensitivity by two—three times compared to the sensitivity of the existing devices. The detector sensitivity for ammonia was 60ppb (0.05 mg m-3) for the measurement time of 10s and a 25-mW, 1.53-μm laser beam in the acoustic resonator.

  2. Comparison between two methodologies for urban drainage decision aid.

    PubMed

    Moura, P M; Baptista, M B; Barraud, S

    2006-01-01

    The objective of the present work is to compare two methodologies based on multicriteria analysis for the evaluation of stormwater systems. The first methodology was developed in Brazil and is based on performance-cost analysis, the second one is ELECTRE III. Both methodologies were applied to a case study. Sensitivity and robustness analyses were then carried out. These analyses demonstrate that both methodologies have equivalent results, and present low sensitivity and high robustness. These results prove that the Brazilian methodology is consistent and can be used safely in order to select a good solution or a small set of good solutions that could be compared with more detailed methods afterwards.

  3. The interrelationship between self-image disparity and social competence, defensive style, and adjustment status.

    PubMed

    Mylet, M; Styfco, S J; Zigler, E

    1979-09-01

    Groups of 40 psychiatric and 40 nonpsychiatric male patients were subdivided into equal groups of high and low social competence. Each patient completed a task battery which included three measures of self-image disparity and the Byrne repression-sensitization scale. High competence patients of both types were found to have higher self-image disparities than low competence patients. Psychiatric patients were found to have higher disparity scores than nonpsychiatric patients, although some evidence indicated that this was true only for the low competence groups. Higher scores on the Byrne scale (indicating sensitization) were found for high as compared to low competence patients, and for the psychiatric as compared to nonpsychiatric groups. Defensive style correlated significantly with each of the self-image measures. The results were discussed in the context of both developmental and Rogerian formulations. It was concluded that an individual's maturational level influences both self-image and defensive style, even when the individual is judged psychologically maladjusted.

  4. A High-Sensitivity Potentiometric 65-nm CMOS ISFET Sensor for Rapid E. coli Screening.

    PubMed

    Jiang, Yu; Liu, Xu; Dang, Tran Chien; Huang, Xiwei; Feng, Hao; Zhang, Qing; Yu, Hao

    2018-04-01

    Foodborne bacteria, inducing outbreaks of infection or poisoning, have posed great threats to food safety. Potentiometric sensors can identify bacteria levels in food by measuring medium's pH changes. However, most of these sensors face the limitation of low sensitivity and high cost. In this paper, we developed a high-sensitivity ion-sensitive field-effect transistor sensor. It is small sized, cost-efficient, and can be massively fabricated in a standard 65-nm complementary metal-oxide-semiconductor process. A subthreshold pH-to-time-to-voltage conversion scheme was proposed to improve the sensitivity. Furthermore, design parameters, such as chemical sensing area, transistor size, and discharging time, were optimized to enhance the performance. The intrinsic sensitivity of passivation membrane was calculated as 33.2 mV/pH. It was amplified to 123.8 mV/pH with a 0.01-pH resolution, which greatly exceeded 6.3 mV/pH observed in a traditional source-follower based readout structure. The sensing system was applied to Escherichia coli (E. coli) detection with densities ranging from 14 to 140 cfu/mL. Compared to the conventional direct plate counting method (24 h), more efficient sixfold smaller screening time (4 h) was achieved to differentiate samples' E. coli levels. The demonstrated portable, time-saving, and low-cost prescreen system has great potential for food safety detection.

  5. Anatomical evidence for low frequency sensitivity in an archaeocete whale: comparison of the inner ear of Zygorhiza kochii with that of crown Mysticeti.

    PubMed

    Ekdale, Eric G; Racicot, Rachel A

    2015-01-01

    The evolution of hearing in cetaceans is a matter of current interest given that odontocetes (toothed whales) are sensitive to high frequency sounds and mysticetes (baleen whales) are sensitive to low and potentially infrasonic noises. Earlier diverging stem cetaceans (archaeocetes) were hypothesized to have had either low or high frequency sensitivity. Through CT scanning, the morphology of the bony labyrinth of the basilosaurid archaeocete Zygorhiza kochii is described and compared to novel information from the inner ears of mysticetes, which are less known than the inner ears of odontocetes. Further comparisons are made with published information for other cetaceans. The anatomy of the cochlea of Zygorhiza is in line with mysticetes and supports the hypothesis that Zygorhiza was sensitive to low frequency noises. Morphological features that support the low frequency hypothesis and are shared by Zygorhiza and mysticetes include a long cochlear canal with a high number of turns, steeply graded curvature of the cochlear spiral in which the apical turn is coiled tighter than the basal turn, thin walls separating successive turns that overlap in vestibular view, and reduction of the secondary bony lamina. Additional morphology of the vestibular system indicates that Zygorhiza was more sensitive to head rotations than extant mysticetes are, which likely indicates higher agility in the ancestral taxon. © 2014 Anatomical Society.

  6. Anatomical evidence for low frequency sensitivity in an archaeocete whale: comparison of the inner ear of Zygorhiza kochii with that of crown Mysticeti

    PubMed Central

    Ekdale, Eric G; Racicot, Rachel A

    2015-01-01

    The evolution of hearing in cetaceans is a matter of current interest given that odontocetes (toothed whales) are sensitive to high frequency sounds and mysticetes (baleen whales) are sensitive to low and potentially infrasonic noises. Earlier diverging stem cetaceans (archaeocetes) were hypothesized to have had either low or high frequency sensitivity. Through CT scanning, the morphology of the bony labyrinth of the basilosaurid archaeocete Zygorhiza kochii is described and compared to novel information from the inner ears of mysticetes, which are less known than the inner ears of odontocetes. Further comparisons are made with published information for other cetaceans. The anatomy of the cochlea of Zygorhiza is in line with mysticetes and supports the hypothesis that Zygorhiza was sensitive to low frequency noises. Morphological features that support the low frequency hypothesis and are shared by Zygorhiza and mysticetes include a long cochlear canal with a high number of turns, steeply graded curvature of the cochlear spiral in which the apical turn is coiled tighter than the basal turn, thin walls separating successive turns that overlap in vestibular view, and reduction of the secondary bony lamina. Additional morphology of the vestibular system indicates that Zygorhiza was more sensitive to head rotations than extant mysticetes are, which likely indicates higher agility in the ancestral taxon. PMID:25400023

  7. Anxiety, its relation to symptoms severity and anxiety sensitivity in sarcoidosis.

    PubMed

    Holas, Pawel; Krejtz, Izabela; Urbankowski, Tomasz; Skowyra, Artur; Ludwiniak, Anna; Domagala-Kulawik, Joanna

    2013-12-17

    Sarcoidosis is a chronic systemic granulomatous disease of unknown etiology. Previous studies demonstrated that patients with sarcoidosis had high rates of depression and anxiety, and high magnitude of stressful life events. To date, however, studies have not examined the anxiety sensitivity in sarcoid patients and the relationship between psychopathology and symptom severity of sarcoidosis.The aims of this study were to evaluate prevalence of depression and anxiety in sarcoid patients, to assess their relationship with the disease symptom severity, and to investigate the relationship between sarcoidosis and anxiety sensitivity. Thirty three sarcoid patients and thirty three control subjects completed the following:Hospital Anxiety and Depression Scale, Anxiety Sensitivity Index-3. The prevalence of depression (29%) and anxiety (31%) was high among patients and comparable to results from other research groups. Anxiety was significantly correlated with symptom severity and was the main covariate of physical symptoms reported by sarcoid patients. Patients exhibited an increase of their total anxiety sensitivity index and had an increased number of physical concerns. These data confirmed earlier reports that anxiety and depression are common in patients with sarcoidosis and expanded on the previous results by showing that patients exhibited increased anxiety sensitivity and a fear of physical sensations. These results, together with the findings that anxiety was associated with sarcoidosis symptom severity, suggest that targeting anxiety and the physical health concerns may be important in the diagnosis and management of this disease.

  8. Bombykol receptors in the silkworm moth and the fruit fly

    PubMed Central

    Syed, Zainulabeuddin; Kopp, Artyom; Kimbrell, Deborah A.; Leal, Walter S.

    2010-01-01

    Male moths are endowed with odorant receptors (ORs) to detect species-specific sex pheromones with remarkable sensitivity and selectivity. We serendipitously discovered that an endogenous OR in the fruit fly, Drosophila melanogaster, is highly sensitive to the sex pheromone of the silkworm moth, bombykol. Intriguingly, the fruit fly detectors are more sensitive than the receptors of the silkworm moth, although its ecological significance is unknown. By expression in the “empty neuron” system, we identified the fruit fly bombykol-sensitive OR as DmelOR7a (= DmOR7a). The profiles of this receptor in response to bombykol in the native sensilla (ab4) or expressed in the empty neuron system (ab3 sensilla) are indistinguishable. Both WT and transgenic flies responded with high sensitivity, in a dose-dependent manner, and with rapid signal termination. In contrast, the same empty neuron expressing the moth bombykol receptor, BmorOR1, demonstrated low sensitivity and slow signal inactivation. When expressed in the trichoid sensilla T1 of the fruit fly, the neuron housing BmorOR1 responded with sensitivity comparable to that of the native trichoid sensilla in the silkworm moth. By challenging the native bombykol receptor in the fruit fly with high doses of another odorant to which the receptor responds with the highest sensitivity, we demonstrate that slow signal termination is induced by overdose of a stimulus. As opposed to the empty neuron system in the basiconic sensilla, the structural, biochemical, and/or biophysical features of the sensilla make the T1 trichoid system of the fly a better surrogate for the moth receptor. PMID:20439725

  9. Improved sensing characteristics of dual-gate transistor sensor using silicon nanowire arrays defined by nanoimprint lithography.

    PubMed

    Lim, Cheol-Min; Lee, In-Kyu; Lee, Ki Joong; Oh, Young Kyoung; Shin, Yong-Beom; Cho, Won-Ju

    2017-01-01

    This work describes the construction of a sensitive, stable, and label-free sensor based on a dual-gate field-effect transistor (DG FET), in which uniformly distributed and size-controlled silicon nanowire (SiNW) arrays by nanoimprint lithography act as conductor channels. Compared to previous DG FETs with a planar-type silicon channel layer, the constructed SiNW DG FETs exhibited superior electrical properties including a higher capacitive-coupling ratio of 18.0 and a lower off-state leakage current under high-temperature stress. In addition, while the conventional planar single-gate (SG) FET- and planar DG FET-based pH sensors showed the sensitivities of 56.7 mV/pH and 439.3 mV/pH, respectively, the SiNW DG FET-based pH sensors showed not only a higher sensitivity of 984.1 mV/pH, but also a lower drift rate of 0.8% for pH-sensitivity. This demonstrates that the SiNW DG FETs simultaneously achieve high sensitivity and stability, with significant potential for future biosensing applications.

  10. High-sensitivity bend angle measurements using optical fiber gratings.

    PubMed

    Rauf, Abdul; Zhao, Jianlin; Jiang, Biqiang

    2013-07-20

    We present a high-sensitivity and more flexible bend measurement method, which is based on the coupling of core mode to the cladding modes at the bending region in concatenation with optical fiber grating serving as band reflector. The characteristics of a bend sensing arm composed of bending region and optical fiber grating is examined for different configurations including single fiber Bragg grating (FBG), chirped FBG (CFBG), and double FBGs. The bend loss curves for coated, stripped, and etched sections of fiber in the bending region with FBG, CFBG, and double FBG are obtained experimentally. The effect of separation between bending region and optical fiber grating on loss is measured. The loss responses for single FBG and CFBG configurations are compared to discover the effectiveness for practical applications. It is demonstrated that the sensitivity of the double FBG scheme is twice that of the single FBG and CFBG configurations, and hence acts as sensitivity multiplier. The bend loss response for different fiber diameters obtained through etching in 40% hydrofluoric acid, is measured in double FBG scheme that resulted in a significant increase in the sensitivity, and reduction of dead-zone.

  11. An integrated approach to panic prevention targeting the empirically supported risk factors of smoking and anxiety sensitivity: theoretical basis and evidence from a pilot project evaluating feasibility and short-term efficacy.

    PubMed

    Feldner, Matthew T; Zvolensky, Michael J; Babson, Kimberly; Leen-Feldner, Ellen W; Schmidt, Norman B

    2008-10-01

    Consistent with a risk reduction model of targeted prevention, the present investigation piloted and empirically evaluated the feasibility and short-term efficacy of a first-generation panic prevention program that targeted two malleable risk factors for panic development-anxiety sensitivity and daily cigarette smoking. Members of a high risk cohort, defined by high levels of anxiety sensitivity and current daily smoking (n=96), were randomly assigned to either (1) a one session intervention focused on proximally increasing motivation to quit smoking and reducing anxiety sensitivity to distally prevent the development of panic or (2) a health information control condition of comparable length. Participants were followed for 6 months. Consistent with hypotheses, those in the treatment condition showed reduced anxiety sensitivity and this effect was maintained across the follow-up period. Limited evidence also suggested the intervention increased motivation to quit smoking. We discuss how this prevention protocol can be modified in the future to enhance its effects as part of second-generation larger-scale outcome evaluations.

  12. Improved sensing characteristics of dual-gate transistor sensor using silicon nanowire arrays defined by nanoimprint lithography

    NASA Astrophysics Data System (ADS)

    Lim, Cheol-Min; Lee, In-Kyu; Lee, Ki Joong; Oh, Young Kyoung; Shin, Yong-Beom; Cho, Won-Ju

    2017-12-01

    This work describes the construction of a sensitive, stable, and label-free sensor based on a dual-gate field-effect transistor (DG FET), in which uniformly distributed and size-controlled silicon nanowire (SiNW) arrays by nanoimprint lithography act as conductor channels. Compared to previous DG FETs with a planar-type silicon channel layer, the constructed SiNW DG FETs exhibited superior electrical properties including a higher capacitive-coupling ratio of 18.0 and a lower off-state leakage current under high-temperature stress. In addition, while the conventional planar single-gate (SG) FET- and planar DG FET-based pH sensors showed the sensitivities of 56.7 mV/pH and 439.3 mV/pH, respectively, the SiNW DG FET-based pH sensors showed not only a higher sensitivity of 984.1 mV/pH, but also a lower drift rate of 0.8% for pH-sensitivity. This demonstrates that the SiNW DG FETs simultaneously achieve high sensitivity and stability, with significant potential for future biosensing applications.

  13. High sensitive and direct fluorescence detection of single viral DNA sequences by integration of double strand probes onto microgels particles.

    PubMed

    Aliberti, A; Cusano, A M; Battista, E; Causa, F; Netti, P A

    2016-02-21

    A novel class of probes for fluorescence detection was developed and combined to microgel particles for a high sensitive fluorescence detection of nucleic acids. A double strand probe with an optimized fluorescent-quencher couple was designed for the detection of different lengths of nucleic acids (39 nt and 100 nt). Such probe proved efficient in target detection in different contests and specific even in presence of serum proteins. The conjugation of double strand probes onto polymeric microgels allows for a sensitive detection of DNA sequences from HIV, HCV and SARS corona viruses with a LOD of 1.4 fM, 3.7 fM and 1.4 fM, respectively, and with a dynamic range of 10(-9)-10(-15) M. Such combination enhances the sensitivity of the detection of almost five orders of magnitude when compared to the only probe. The proposed platform based on the integration of innovative double strand probe into microgels particles represents an attractive alternative to conventional sensitive DNA detection technologies that rely on amplifications methods.

  14. Human sensitivity to vertical self-motion.

    PubMed

    Nesti, Alessandro; Barnett-Cowan, Michael; Macneilage, Paul R; Bülthoff, Heinrich H

    2014-01-01

    Perceiving vertical self-motion is crucial for maintaining balance as well as for controlling an aircraft. Whereas heave absolute thresholds have been exhaustively studied, little work has been done in investigating how vertical sensitivity depends on motion intensity (i.e., differential thresholds). Here we measure human sensitivity for 1-Hz sinusoidal accelerations for 10 participants in darkness. Absolute and differential thresholds are measured for upward and downward translations independently at 5 different peak amplitudes ranging from 0 to 2 m/s(2). Overall vertical differential thresholds are higher than horizontal differential thresholds found in the literature. Psychometric functions are fit in linear and logarithmic space, with goodness of fit being similar in both cases. Differential thresholds are higher for upward as compared to downward motion and increase with stimulus intensity following a trend best described by two power laws. The power laws' exponents of 0.60 and 0.42 for upward and downward motion, respectively, deviate from Weber's Law in that thresholds increase less than expected at high stimulus intensity. We speculate that increased sensitivity at high accelerations and greater sensitivity to downward than upward self-motion may reflect adaptations to avoid falling.

  15. An efficient method of reducing glass dispersion tolerance sensitivity

    NASA Astrophysics Data System (ADS)

    Sparrold, Scott W.; Shepard, R. Hamilton

    2014-12-01

    Constraining the Seidel aberrations of optical surfaces is a common technique for relaxing tolerance sensitivities in the optimization process. We offer an observation that a lens's Abbe number tolerance is directly related to the magnitude by which its longitudinal and transverse color are permitted to vary in production. Based on this observation, we propose a computationally efficient and easy-to-use merit function constraint for relaxing dispersion tolerance sensitivity. Using the relationship between an element's chromatic aberration and dispersion sensitivity, we derive a fundamental limit for lens scale and power that is capable of achieving high production yield for a given performance specification, which provides insight on the point at which lens splitting or melt fitting becomes necessary. The theory is validated by comparing its predictions to a formal tolerance analysis of a Cooke Triplet, and then applied to the design of a 1.5x visible linescan lens to illustrate optimization for reduced dispersion sensitivity. A selection of lenses in high volume production is then used to corroborate the proposed method of dispersion tolerance allocation.

  16. Estimation of resist sensitivity for extreme ultraviolet lithography using an electron beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oyama, Tomoko Gowa, E-mail: ohyama.tomoko@qst.go.jp; Oshima, Akihiro; Tagawa, Seiichi, E-mail: tagawa@sanken.osaka-u.ac.jp

    2016-08-15

    It is a challenge to obtain sufficient extreme ultraviolet (EUV) exposure time for fundamental research on developing a new class of high sensitivity resists for extreme ultraviolet lithography (EUVL) because there are few EUV exposure tools that are very expensive. In this paper, we introduce an easy method for predicting EUV resist sensitivity by using conventional electron beam (EB) sources. If the chemical reactions induced by two ionizing sources (EB and EUV) are the same, the required absorbed energies corresponding to each required exposure dose (sensitivity) for the EB and EUV would be almost equivalent. Based on this theory, wemore » calculated the resist sensitivities for the EUV/soft X-ray region. The estimated sensitivities were found to be comparable to the experimentally obtained sensitivities. It was concluded that EB is a very useful exposure tool that accelerates the development of new resists and sensitivity enhancement processes for 13.5 nm EUVL and 6.x nm beyond-EUVL (BEUVL).« less

  17. Facile fabrication of networked patterns and their superior application to realize the virus immobilized networked pattern circuit.

    PubMed

    Choi, Kyung Min; Lee, Seok Jae; Choi, Jung Hoon; Park, Tae Jung; Park, Jong Wan; Shin, Weon Ho; Kang, Jeung Ku

    2010-12-07

    A facile route to fabricate a protein-immobilized network pattern circuit for rapid and highly sensitive diagnosis was developed via the evaporation directed impromptu patterning method and selective avian influenza virus (AIV) immobilization. The response to the 10 fg mL(-1) anti-AI antibody demonstrates that this easy and simple circuit has about 1000 times higher sensitivity compared to those of conventional approaches.

  18. A Protein Microarray ELISA for the Detection of Botulinum neurotoxin A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varnum, Susan M.

    An enzyme-linked immunosorbent assay (ELISA) microarray was developed for the specific and sensitive detection of botulinum neurotoxin A (BoNT/A), using high-affinity recombinant monoclonal antibodies against the receptor binding domain of the heavy chain of BoNT/A. The ELISA microarray assay, because of its sensitivity, offers a screening test with detection limits comparable to the mouse bioassay, with results available in hours instead of days.

  19. Effects of High vs Low Glycemic Index of Dietary Carbohydrate on Cardiovascular Disease Risk Factors and Insulin Sensitivity

    PubMed Central

    Sacks, Frank M.; Carey, Vincent J.; Anderson, Cheryl A. M.; Miller, Edgar R.; Copeland, Trisha; Charleston, Jeanne; Harshfield, Benjamin J.; Laranjo, Nancy; McCarron, Phyllis; Swain, Janis; White, Karen; Yee, Karen; Appel, Lawrence J.

    2015-01-01

    IMPORTANCE Foods that have similar carbohydrate content can differ in the amount they raise blood glucose. The effects of this property, called the glycemic index, on risk factors for cardiovascular disease and diabetes are not well understood. OBJECTIVE To determine the effect of glycemic index and amount of total dietary carbohydrate on risk factors for cardiovascular disease and diabetes. DESIGN, SETTING, AND PARTICIPANTS Randomized crossover-controlled feeding trial conducted in research units in academic medical centers, in which 163 overweight adults (systolic blood pressure, 120–159 mm Hg) were given 4 complete diets that contained all of their meals, snacks, and calorie-containing beverages, each for 5 weeks, and completed at least 2 study diets. The first participant was enrolled April 1, 2008; the last participant finished December 22, 2010. For any pair of the 4 diets, there were 135 to 150 participants contributing at least 1 primary outcome measure. INTERVENTIONS (1) A high–glycemic index (65% on the glucose scale), high-carbohydrate diet (58% energy); (2) a low–glycemic index (40%), high-carbohydrate diet; (3) a high–glycemic index, low-carbohydrate diet (40% energy); and (4) a low–glycemic index, low-carbohydrate diet. Each diet was based on a healthful DASH-type diet. MAIN OUTCOMES AND MEASURES The 5 primary outcomes were insulin sensitivity, determined from the areas under the curves of glucose and insulin levels during an oral glucose tolerance test; levels of low-density lipoprotein (LDL) cholesterol, high-density lipoprotein (HDL) cholesterol, and triglycerides; and systolic blood pressure. RESULTS At high dietary carbohydrate content, the low– compared with high–glycemic index level decreased insulin sensitivity from 8.9 to 7.1 units (−20%, P = .002); increased LDL cholesterol from 139 to 147 mg/dL (6%, P ≤ .001); and did not affect levels of HDL cholesterol, triglycerides, or blood pressure. At low carbohydrate content, the low– compared with high–glycemic index level did not affect the outcomes except for decreasing triglycerides from 91 to 86 mg/dL (−5%, P = .02). In the primary diet contrast, the low–glycemic index, low-carbohydrate diet, compared with the high–glycemic index, high-carbohydrate diet, did not affect insulin sensitivity, systolic blood pressure, LDL cholesterol, or HDL cholesterol but did lower triglycerides from 111 to 86 mg/dL (−23%, P ≤ .001). CONCLUSIONS AND RELEVANCE In this 5-week controlled feeding study, diets with low glycemic index of dietary carbohydrate, compared with high glycemic index of dietary carbohydrate, did not result in improvements in insulin sensitivity, lipid levels, or systolic blood pressure. In the context of an overall DASH-type diet, using glycemic index to select specific foods may not improve cardiovascular risk factors or insulin resistance. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00608049 PMID:25514303

  20. Sensitivity and specificity of the online version of ImPACT in high school and collegiate athletes.

    PubMed

    Schatz, Philip; Sandel, Natalie

    2013-02-01

    The utility of postconcussion neurocognitive testing versus symptom data has been debated. The sensitivity of the desktop version of the Immediate Post-concussion assessment and cognitive testing (ImPACT) tool has been documented, but psychometric properties of the recently released online version of ImPACT have yet to be fully established. To document the sensitivity of the online ImPACT version in samples of (1) symptomatic concussed (high school and collegiate) athletes, and (2) asymptomatic concussed (high school and collegiate) athletes suspected of hiding their concussions. Cohort study; level of evidence, 3. A total of 81 athletes observed to sustain a concussion by a certified athletic trainer or team physician, a finding that was confirmed with reported postconcussion symptoms, completed the ImPACT test within 3 days of injury. Data were compared with an independent sample of 81 athletes who completed preseason baseline cognitive assessments using ImPACT and who were matched (with concussed athletes) on the basis of sex, age, sport, concussion history, and absence of attention deficit hyperactivity disorder and learning disability. An independent group of 37 athletes who were also observed to sustain a concussion completed ImPACT within 3 days of injury. These athletes reported no postconcussion symptoms but were noted for suspected invalid response patterns on ImPACT (impulse control index >30 and verbal memory index <69%). The subscale data from the assessments (excluding those contributing to the aforementioned indices) were compared with a matched sample of 37 athletes who completed preseason baseline cognitive assessments in ImPACT (using the same criteria described above). Data from the ImPACT online version yielded 91.4% sensitivity and 69.1% specificity. For asymptomatic athletes suspected of hiding their concussion, data from ImPACT yielded 94.6% sensitivity and 97.3% specificity. The online version of the ImPACT tool is a valid measure of neurocognitive performance at the acute stages of concussion, with high levels of sensitivity and specificity, even when athletes appear to be denying postconcussion symptoms.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Katherine L.; Judenhofer, Martin S.; Cherry, Simon R.

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. Furthermore, such high-resolution systems have relatively poor sensitivity (typically 0.01% to 0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatialmore » resolution, linearity, detection limits, and uniformity. With 99mTc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99mTc MAG-3 and a thyroid scan with 123I) and one plant study (a 99mTcO 4- xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. In conclusion, UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.« less

  2. Sensitivity and specificity of linear array intraoperative ultrasound in glioblastoma surgery: a comparative study with high field intraoperative MRI and conventional sector array ultrasound.

    PubMed

    Coburger, Jan; Scheuerle, Angelika; Kapapa, Thomas; Engelke, Jens; Thal, Dietmar Rudolf; Wirtz, Christian R; König, Ralph

    2015-07-01

    Linear array intraoperative ultrasound (lioUS) is an emerging technology for intracranial use. We evaluated sensitivity and specificity of lioUS to detect residual tumor in patients harboring a glioblastoma. After near total resection in 20 patients, residual tumor detection using lioUS, conventional intraoperative ultrasound (cioUS), and gadopentetic-diethylenetriamine penta-acetic acid (Gd-DTPA)-enhanced intraoperative MRI (iMRI) were compared. Sensitivity and specificity were calculated based on 68 navigated biopsies. Receiver operator characteristic (ROC) curves and correlation with histopathological findings of each imaging modality were calculated. Additionally, results were evaluated in the subgroup of recurrent disease (23 biopsies in 8 patients). Sensitivity of lioUS (76 %) was significantly higher compared with iMRI (55 %) and cioUS (24 %). Specificity of lioUS (58 %) was significantly lower than in cioUS (96 %), while there was no significant difference to iMRI (74 %). All imaging modalities correlated significantly with histopathological findings. In the subgroup of recurrent disease, sensitivity and specificity decreased in all modalities. However, cioUS showed significant lower values than iMRI and lioUS. In ROC curves, lioUS showed a higher area und the curve (AUC) in comparison with iMRI and cioUS. We found similar results in the subgroup of recurrent disease. Tumor detection using a lioUS is significantly superior to cioUS. Overall test performance in lioUS is comparable with results of iMRI. While, the latter has a higher specificity and a significantly lower sensitivity in comparison with lioUS.

  3. Environmental and Hydroclimatic Sensitivities of Greenhouse Gas (GHG) Fluxes from Coastal Wetlands

    NASA Astrophysics Data System (ADS)

    Abdul-Aziz, O. I.; Ishtiaq, K. S.

    2016-12-01

    We computed the reference environmental and hydroclimatic sensitivities of the greenhouse gas (GHG) fluxes (CO2 and CH4) from coastal salt marshes. Non-linear partial least squares regression models of CO2 (net uptake) and CH4 (net emissions) fluxes were developed with a bootstrap resampling approach using the photosynthetically active radiation (PAR), air and soil temperatures, water height, soil moisture, porewater salinity, and pH as predictors. Analytical sensitivity coefficients of different predictors were then analytically derived from the estimated models. The numerical sensitivities of the dominant drivers were determined by perturbing the variables individually and simultaneously to compute their individual and combined (respectively) effects on the GHG fluxes. Four tidal wetlands of Waquoit Bay, MA — incorporating a gradient in land-use, salinity and hydrology — were considered as the case study sites. The wetlands were dominated by native Spartina Alterniflora, and characterized by high salinity and frequent flooding. Results indicated a high sensitivity of CO2 fluxes to temperature and PAR, a moderate sensitivity to soil salinity and water height, and a weak sensitivity to pH and soil moisture. In contrast, the CH4 fluxes were more sensitive to temperature and salinity, compared to that of PAR, pH, and hydrologic variables. The estimated sensitivities and mechanistic insights can aid the management of coastal carbon under a changing climate and environment. The sensitivity coefficients also indicated the most dominant drivers of GHG fluxes for the development of a parsimonious predictive model.

  4. High-k dielectric Al2O3 nanowire and nanoplate field effect sensors for improved pH sensing

    PubMed Central

    Reddy, Bobby; Dorvel, Brian R.; Go, Jonghyun; Nair, Pradeep R.; Elibol, Oguz H.; Credo, Grace M.; Daniels, Jonathan S.; Chow, Edmond K. C.; Su, Xing; Varma, Madoo; Alam, Muhammad A.

    2011-01-01

    Over the last decade, field-effect transistors (FETs) with nanoscale dimensions have emerged as possible label-free biological and chemical sensors capable of highly sensitive detection of various entities and processes. While significant progress has been made towards improving their sensitivity, much is yet to be explored in the study of various critical parameters, such as the choice of a sensing dielectric, the choice of applied front and back gate biases, the design of the device dimensions, and many others. In this work, we present a process to fabricate nanowire and nanoplate FETs with Al2O3 gate dielectrics and we compare these devices with FETs with SiO2 gate dielectrics. The use of a high-k dielectric such as Al2O3 allows for the physical thickness of the gate dielectric to be thicker without losing sensitivity to charge, which then reduces leakage currents and results in devices that are highly robust in fluid. This optimized process results in devices stable for up to 8 h in fluidic environments. Using pH sensing as a benchmark, we show the importance of optimizing the device bias, particularly the back gate bias which modulates the effective channel thickness. We also demonstrate that devices with Al2O3 gate dielectrics exhibit superior sensitivity to pH when compared to devices with SiO2 gate dielectrics. Finally, we show that when the effective electrical silicon channel thickness is on the order of the Debye length, device response to pH is virtually independent of device width. These silicon FET sensors could become integral components of future silicon based Lab on Chip systems. PMID:21203849

  5. Comparison of Abbott RealTime High-Risk HPV and Hybrid Capture 2 Assays for Detection of HPV Infection.

    PubMed

    Ko, Kiwoong; Yu, Shinae; Lee, Eun Hee; Park, Hyosoon; Woo, Hee-Yeon; Kwon, Min-Jung

    2016-09-01

    Various assays for detecting high-risk human papillomavirus (HR HPV) have been introduced recently, including the Abbott RealTime High-Risk HPV assay. We sought to compare the performance of Abbott PCR to Hybrid Capture 2 for the detection of HR HPV. A total of 941 cervical swab specimens were obtained. We submitted all specimens for HR HPV detection with HC2 and Abbott PCR, and then additionally analyzed discordant and concordant positive results using restriction fragment mass polymorphism (RFMP) genotyping analysis. HC2 detected one of 13 HR HPV types in 12.3% (116/941) of cases, while Abbott PCR detected one of 14 detectable HR HPV types in 12.9% (121/941) of cases. The overall agreement rate was 97.3% with a kappa coefficient of 0.879. Discordant results between these two assays were observed in 25 cases. HC2 showed a sensitivity of 90.0% and specificity of 95.9%, while Abbott PCR showed a sensitivity of 98.0% and specificity of 96.8% when using RFMP results as the gold standard. For HPV 16/18 detection, Abbott PCR showed 95.8%/88.9% sensitivity and 99.2%/99.8% specificity, respectively. The overall coinfection rate between HPV 16, 18 and non-16/18 was 9.9% (12/121) in Abbott PCR analysis. Considering its high agreement rate with HC2, higher sensitivity/specificity compared to HC2, and ability to differentiate HPV 16/18 from other HPV types, Abbott PCR could be a reliable laboratory testing method for the screening of HPV infections. © 2016 by the Association of Clinical Scientists, Inc.

  6. Screening for prenatal substance use: development of the Substance Use Risk Profile-Pregnancy scale.

    PubMed

    Yonkers, Kimberly A; Gotman, Nathan; Kershaw, Trace; Forray, Ariadna; Howell, Heather B; Rounsaville, Bruce J

    2010-10-01

    To report on the development of a questionnaire to screen for hazardous substance use in pregnant women and to compare the performance of the questionnaire with other drug and alcohol measures. Pregnant women were administered a modified TWEAK (Tolerance, Worried, Eye-openers, Amnesia, K[C] Cut Down) questionnaire, the 4Ps Plus questionnaire, items from the Addiction Severity Index, and two questions about domestic violence (N=2,684). The sample was divided into "training" (n=1,610) and "validation" (n=1,074) subsamples. We applied recursive partitioning class analysis to the responses from individuals in the training subsample that resulted in a three-item Substance Use Risk Profile-Pregnancy scale. We examined sensitivity, specificity, and the fit of logistic regression models in the validation subsample to compare the performance of the Substance Use Risk Profile-Pregnancy scale with the modified TWEAK and various scoring algorithms of the 4Ps. The Substance Use Risk Profile-Pregnancy scale is comprised of three informative questions that can be scored for high- or low-risk populations. The Substance Use Risk Profile-Pregnancy scale algorithm for low-risk populations was mostly highly predictive of substance use in the validation subsample (Akaike's Information Criterion=579.75, Nagelkerke R=0.27) with high sensitivity (91%) and adequate specificity (67%). The high-risk algorithm had lower sensitivity (57%) but higher specificity (88%). The Substance Use Risk Profile-Pregnancy scale is simple and flexible with good sensitivity and specificity. The Substance Use Risk Profile-Pregnancy scale can potentially detect a range of substances that may be abused. Clinicians need to further assess women with a positive screen to identify those who require treatment for alcohol or illicit substance use in pregnancy. III.

  7. Field-effect sensors - from pH sensing to biosensing: sensitivity enhancement using streptavidin-biotin as a model system.

    PubMed

    Lowe, Benjamin M; Sun, Kai; Zeimpekis, Ioannis; Skylaris, Chris-Kriton; Green, Nicolas G

    2017-11-06

    Field-Effect Transistor sensors (FET-sensors) have been receiving increasing attention for biomolecular sensing over the last two decades due to their potential for ultra-high sensitivity sensing, label-free operation, cost reduction and miniaturisation. Whilst the commercial application of FET-sensors in pH sensing has been realised, their commercial application in biomolecular sensing (termed BioFETs) is hindered by poor understanding of how to optimise device design for highly reproducible operation and high sensitivity. In part, these problems stem from the highly interdisciplinary nature of the problems encountered in this field, in which knowledge of biomolecular-binding kinetics, surface chemistry, electrical double layer physics and electrical engineering is required. In this work, a quantitative analysis and critical review has been performed comparing literature FET-sensor data for pH-sensing with data for sensing of biomolecular streptavidin binding to surface-bound biotin systems. The aim is to provide the first systematic, quantitative comparison of BioFET results for a single biomolecular analyte, specifically streptavidin, which is the most commonly used model protein in biosensing experiments, and often used as an initial proof-of-concept for new biosensor designs. This novel quantitative and comparative analysis of the surface potential behaviour of a range of devices demonstrated a strong contrast between the trends observed in pH-sensing and those in biomolecule-sensing. Potential explanations are discussed in detail and surface-chemistry optimisation is shown to be a vital component in sensitivity-enhancement. Factors which can influence the response, yet which have not always been fully appreciated, are explored and practical suggestions are provided on how to improve experimental design.

  8. Scanning magnetic tunnel junction microscope for high-resolution imaging of remanent magnetization fields

    NASA Astrophysics Data System (ADS)

    Lima, E. A.; Bruno, A. C.; Carvalho, H. R.; Weiss, B. P.

    2014-10-01

    Scanning magnetic microscopy is a new methodology for mapping magnetic fields with high spatial resolution and field sensitivity. An important goal has been to develop high-performance instruments that do not require cryogenic technology due to its high cost, complexity, and limitation on sensor-to-sample distance. Here we report the development of a low-cost scanning magnetic microscope based on commercial room-temperature magnetic tunnel junction (MTJ) sensors that typically achieves spatial resolution better than 7 µm. By comparing different bias and detection schemes, optimal performance was obtained when biasing the MTJ sensor with a modulated current at 1.0 kHz in a Wheatstone bridge configuration while using a lock-in amplifier in conjunction with a low-noise custom-made preamplifier. A precision horizontal (x-y) scanning stage comprising two coupled nanopositioners controls the position of the sample and a linear actuator adjusts the sensor-to-sample distance. We obtained magnetic field sensitivities better than 150 nT/Hz1/2 between 0.1 and 10 Hz, which is a critical frequency range for scanning magnetic microscopy. This corresponds to a magnetic moment sensitivity of 10-14 A m2, a factor of 100 better than achievable with typical commercial superconducting moment magnetometers. It also represents an improvement in sensitivity by a factor between 10 and 30 compared to similar scanning MTJ microscopes based on conventional bias-detection schemes. To demonstrate the capabilities of the instrument, two polished thin sections of representative geological samples were scanned along with a synthetic sample containing magnetic microparticles. The instrument is usable for a diversity of applications that require mapping of samples at room temperature to preserve magnetic properties or viability, including paleomagnetism and rock magnetism, nondestructive evaluation of materials, and biological assays.

  9. Screening for Prenatal Substance Use

    PubMed Central

    Yonkers, Kimberly A.; Gotman, Nathan; Kershaw, Trace; Forray, Ariadna; Howell, Heather B.; Rounsaville, Bruce J.

    2011-01-01

    OBJECTIVE To report on the development of a questionnaire to screen for hazardous substance use in pregnant women and to compare the performance of the questionnaire with other drug and alcohol measures. METHODS Pregnant women were administered a modified TWEAK (Tolerance, Worried, Eye-openers, Amnesia, K[C] Cut Down) questionnaire, the 4Ps Plus questionnaire, items from the Addiction Severity Index, and two questions about domestic violence (N=2,684). The sample was divided into “training” (n=1,610) and “validation” (n=1,074) subsamples. We applied recursive partitioning class analysis to the responses from individuals in the training subsample that resulted in a three-item Substance Use Risk Profile-Pregnancy scale. We examined sensitivity, specificity, and the fit of logistic regression models in the validation subsample to compare the performance of the Substance Use Risk Profile-Pregnancy scale with the modified TWEAK and various scoring algorithms of the 4Ps. RESULTS The Substance Use Risk Profile-Pregnancy scale is comprised of three informative questions that can be scored for high- or low-risk populations. The Substance Use Risk Profile-Pregnancy scale algorithm for low-risk populations was mostly highly predictive of substance use in the validation subsample (Akaike’s Information Criterion=579.75, Nagelkerke R2=0.27) with high sensitivity (91%) and adequate specificity (67%). The high-risk algorithm had lower sensitivity (57%) but higher specificity (88%). CONCLUSION The Substance Use Risk Profile-Pregnancy scale is simple and flexible with good sensitivity and specificity. The Substance Use Risk Profile-Pregnancy scale can potentially detect a range of substances that may be abused. Clinicians need to further assess women with a positive screen to identify those who require treatment for alcohol or illicit substance use in pregnancy. PMID:20859145

  10. Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina

    NASA Astrophysics Data System (ADS)

    An, Lin; Shen, Tueng T.; Wang, Ruikang K.

    2011-10-01

    This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of the human eye and head compared to the traditional OMAG system. To mitigate these motion artifacts on final imaging results, we propose a new phase compensation algorithm in which the traditional phase-compensation algorithm is repeatedly used to efficiently minimize the motion artifacts. Comparatively, this new algorithm demonstrates at least 8 to 25 times higher motion tolerability, critical for the UHS-OMAG system to achieve retinal microvasculature images with high quality. Furthermore, the new UHS-OMAG system employs a high speed line scan CMOS camera (240 kHz A-line scan rate) to capture 500 A-lines for one B-frame at a 400 Hz frame rate. With this system, we performed a series of in vivo experiments to visualize the retinal microvasculature in humans. Two featured imaging protocols are utilized. The first is of the low lateral resolution (16 μm) and a wide field of view (4 × 3 mm2 with single scan and 7 × 8 mm2 for multiple scans), while the second is of the high lateral resolution (5 μm) and a narrow field of view (1.5 × 1.2 mm2 with single scan). The great imaging performance delivered by our system suggests that UHS-OMAG can be a promising noninvasive alternative to the current clinical retinal microvasculature imaging techniques for the diagnosis of eye diseases with significant vascular involvement, such as diabetic retinopathy and age-related macular degeneration.

  11. p16/ki-67 dual-stain cytology in the triage of ASCUS and LSIL papanicolaou cytology: results from the European equivocal or mildly abnormal Papanicolaou cytology study.

    PubMed

    Schmidt, Dietmar; Bergeron, Christine; Denton, Karin J; Ridder, Ruediger

    2011-06-25

    The objective of this study was to analyze the diagnostic performance of a newly established immunocytochemical dual-stain protocol, which simultaneously detects p16(INK4a) and Ki-67 expression in cervical cytology samples, for identifying high-grade cervical intraepithelial neoplasia (CIN2+) in women with Papanicolaou (Pap) cytology results categorized as atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesions (LSIL). Residual liquid-based cytology material from 776 retrospectively collected ASCUS/LSIL cases that were available from a recent study evaluating p16 cytology and HPV testing were subjected to p16/Ki-67 dual staining. The presence of 1 or more double-immunoreactive cell(s) was regarded as a positive test outcome, irrespective of morphology. Test results were correlated to histology follow-up. Sensitivity of p16/Ki-67 dual-stain cytology for biopsy-confirmed CIN2+ was 92.2% (ASCUS) and 94.2% (LSIL), while specificity rates were 80.6% (ASCUS) and 68.0% (LSIL), respectively. Similar sensitivity/specificity profiles were found for both age groups of women aged <30 years versus women aged ≥30 years. Dual-stain cytology showed comparable sensitivity, but significantly higher specificity, when compared with human papillomavirus (HPV) testing. The results of this study show that p16/Ki-67 dual-stain cytology provided a high sensitivity for the detection of underlying CIN2+ in women with ASCUS or LSIL Pap cytology results, comparable to the rates previously reported for HPV testing and p16 single-stain cytology. However, the specificity of this morphology-independent interpretation of p16/Ki-67 dual-stain cytology testing was further improved compared with the earlier p16 single-stain cytology approach, which required morphology interpretation, and it is significantly higher when compared with HPV testing. Copyright © 2011 American Cancer Society.

  12. Altered sensitization patterns to sweet food stimuli in patients recovered from anorexia and bulimia nervosa.

    PubMed

    Wagner, Angela; Simmons, Alan N; Oberndorfer, Tyson A; Frank, Guido K W; McCurdy-McKinnon, Danyale; Fudge, Julie L; Yang, Tony T; Paulus, Martin P; Kaye, Walter H

    2015-12-30

    Recent studies show that higher-order appetitive neural circuitry may contribute to restricted eating in anorexia nervosa (AN) and overeating in bulimia nervosa (BN). The purpose of this study was to determine whether sensitization effects might underlie pathologic eating behavior when a taste stimulus is administered repeatedly. Recovered AN (RAN, n=14) and BN (RBN, n=15) subjects were studied in order to avoid the confounding effects of altered nutritional state. Functional magnetic resonance imaging (fMRI) measured higher-order brain response to repeated tastes of sucrose (caloric) and sucralose (non-caloric). To test sensitization, the neuronal response to the first and second administration was compared. RAN patients demonstrated a decreased sensitization to sucrose in contrast to RBN patients who displayed the opposite pattern, increased sensitization to sucrose. However, the latter was not as pronounced as in healthy control women (n=13). While both eating disorder subgroups showed increased sensitization to sucralose, the healthy controls revealed decreased sensitization. These findings could reflect on a neuronal level the high caloric intake of RBN during binges and the low energy intake for RAN. RAN seem to distinguish between high energy and low energy sweet stimuli while RBN do not. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. An inter-laboratory comparison of PNH clone detection by high-sensitivity flow cytometry in a Russian cohort.

    PubMed

    Sipol, Alexandra A; Babenko, Elena V; Borisov, Vyacheslav I; Naumova, Elena V; Boyakova, Elena V; Yakunin, Dimitry I; Glazanova, Tatyana V; Chubukina, Zhanna V; Pronkina, Natalya V; Popov, Alexander M; Saveliev, Leonid I; Lugovskaya, Svetlana A; Lisukov, Igor A; Kulagin, Alexander D; Illingworth, Andrea J

    2015-01-01

    Paroxysmal nocturnal hemoglobinuria (PNH) is an acquired clonal stem cell disorder characterized by partial or absolute deficiency of glycophosphatidyl-inositol (GPI) anchor-linked surface proteins on blood cells. A lack of precise diagnostic standards for flow cytometry has hampered useful comparisons of data between laboratories. We report data from the first study evaluating the reproducibility of high-sensitivity flow cytometry for PNH in Russia. PNH clone sizes were determined at diagnosis in PNH patients at a central laboratory and compared with follow-up measurements in six laboratories across the country. Analyses in each laboratory were performed according to recommendations from the International Clinical Cytometry Society (ICCS) and the more recent 'practical guidelines'. Follow-up measurements were compared with each other and with the values determined at diagnosis. PNH clone size measurements were determined in seven diagnosed PNH patients (five females, two males: mean age 37 years); five had a history of aplastic anemia and three (one with and two without aplastic anemia) had severe hemolytic PNH and elevated plasma lactate dehydrogenase. PNH clone sizes at diagnosis were low in patients with less severe clinical symptoms (0.41-9.7% of granulocytes) and high in patients with severe symptoms (58-99%). There were only minimal differences in the follow-up clone size measurement for each patient between the six laboratories, particularly in those with high values at diagnosis. The ICCS-recommended high-sensitivity flow cytometry protocol was effective for detecting major and minor PNH clones in Russian PNH patients, and showed high reproducibility between laboratories.

  14. Comparative Evaluation of Tubex TF (Inhibition Magnetic Binding Immunoassay) for Typhoid Fever in Endemic Area.

    PubMed

    Khanna, Ashish; Khanna, Menka; Gill, Karamjit Singh

    2015-11-01

    Typhoid fever remains a significant health problem in endemic countries like India. Various serological tests for the diagnosis of typhoid fever are available commercially. We assessed the usefulness of rapid test based on magnetic particle separation to detect Immunoglobulin against Salmonella typhi O9 lipopolysaccharide. Aim of this study was to compare the sensitivity and specificity of widal test, typhidot and tubex TF test for the diagnosis of typhoid fever in an endemic country like India. Serum samples collected from 50 patients of typhoid fever, 50 patients of non typhoid fever and 100 normal healthy individuals residing in Amritsar were subjected to widal test, typhidot test and tubex TF test as per manufacturer's instructions. Data collected was assessed to find sensitivity and specificity of these tests in an endemic area. Significant widal test results were found positive in 68% of patients of typhoid fever and only 4% of non typhoid fever patients. Typhidot (IgM or IgG) was positive in 72% of typhoid fever patients and 10% and 6% in non typhoid fever and normal healthy individuals respectively. Tubex TF showed higher sensitivity of 76% and specificity of 96-99% which was higher than typhidot and comparable to widal test. This was the first evaluation of rapid tubex TF test in northern India. In countries which can afford high cost of test, tubex TF should be recommended for the diagnosis in acute stage of the disease in clinical setting. However, there is urgent need for a highly specific and sensitive test for the diagnosis of typhoid fever in clinical settings in endemic areas.

  15. Stress exposure and sensitivity in the clinical high-risk syndrome: initial findings from the North American Prodrome Longitudinal Study (NAPLS).

    PubMed

    Trotman, Hanan D; Holtzman, Carrie W; Walker, Elaine F; Addington, Jean M; Bearden, Carrie E; Cadenhead, Kristin S; Cannon, Tyrone D; Cornblatt, Barbara A; Heinssen, Robert K; Mathalon, Daniel H; Tsuang, Ming T; Perkins, Diana O; Seidman, Larry J; Woods, Scott W; McGlashan, Thomas H

    2014-12-01

    There is inconsistent evidence for increased stress exposure among individuals at clinical high risk (CHR) for psychosis. Yet similar to patients with a diagnosed psychotic illness, the preponderance of evidence suggests that CHR individuals tend to experience stressful life events (LE) and daily hassles (DH) as more subjectively stressful than healthy individuals. The present study utilizes data from the North American Prodrome Longitudinal Study Phase 2 (NAPLS-2) to test the hypotheses that (1) CHR individuals manifest higher self-reported stress in response to both LE and DH when compared to healthy controls (HC), (2) group differences in self-reported stress increase with age, (3) baseline self-reported stress is associated with follow-up clinical status, and (4) there is a sensitization effect of LE on the response to DH. In contrast to some previous research, the present findings indicate that the CHR group (N=314) reported exposure to more LE when compared to the HC group (N=162). As predicted, CHR participants rated events as more stressful, and those who progressed to psychosis reported a greater frequency of LE and greater stress from events compared to those whose prodromal symptoms remitted. There was also some evidence of stress-sensitization; those who experienced more stress from LE rated current DH as more stressful. The results indicate that the "prodromal" phase is a period of heightened stress and stress sensitivity, and elevated cumulative lifetime exposure to stressful events may increase reactions to current stressors. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Heterozygous Inverdale ewes show increased ovulation rate sensitivity to pre-mating nutrition.

    PubMed

    Demmers, K J; Smaill, B; Davis, G H; Dodds, K G; Juengel, J L

    2011-01-01

    This study aimed to determine whether ewes heterozygous (I+) for the Inverdale mutation of the bone morphogenetic protein-15 (BMP15) gene with high natural ovulation rate (OR) show similar sensitivity to nutritional manipulation as non-carriers (++). Increasing pre-mating nutrition results in OR increases in sheep, but whether this effect occurs in ewes with naturally high OR is unknown. Over 2 years, I+ or ++ ewes were given high (ad libitum) or control (maintenance) pasture allowances for 6 weeks prior to mating at a synchronised oestrus, with OR measured 8 days later. The high group increased in weight compared with controls (+5.84kg; P<0.01), accompanied by increased OR (+19%; P<0.01). As well as having higher OR (+45%; P<0.01), I+ ewes responded to increased feed with a larger proportional increase in OR (+27%; P<0.01) compared with the response in ++ ewes (+11%; P<0.05), suggesting an interaction between BMP15 levels and nutritional signals in the follicle to control OR. Although litter size increases only tended to significance (+12%; P=0.06), extra feed resulted in over 50% of I+ ewes giving birth to more than three lambs, compared with 20-31% of I+ ewes on maintenance rations. This information can guide feed management of prolific Inverdale ewes prior to breeding.

  17. Single-residue molecular switch for high-temperature dependence of vanilloid receptor TRPV3

    PubMed Central

    Liu, Beiying; Qin, Feng

    2017-01-01

    Thermal transient receptor potential (TRP) channels, a group of ion channels from the transient receptor potential family, play important functions in pain and thermal sensation. These channels are directly activated by temperature and possess strong temperature dependence. Furthermore, their temperature sensitivity can be highly dynamic and use-dependent. For example, the vanilloid receptor transient receptor potential 3 (TRPV3), which has been implicated as a warmth detector, becomes responsive to warm temperatures only after intensive stimulation. Upon initial activation, the channel exhibits a high-temperature threshold in the noxious temperature range above 50 °C. This use dependence of heat sensitivity thus provides a mechanism for sensitization of thermal channels. However, how the channels acquire the use dependence remains unknown. Here, by comparative studies of chimeric channels between use-dependent and use-independent homologs, we have determined the molecular basis that underlies the use dependence of temperature sensitivity of TRPV3. Remarkably, the restoration of a single residue that is apparently missing in the use-dependent homologs could largely eliminate the use dependence of heat sensitivity of TRPV3. The location of the region suggests a mechanism of temperature-dependent gating of thermal TRP channels involving an intracellular region assembled around the TRP domain. PMID:28154143

  18. A highly sensitive and selective fluorescent sensor for detection of sulfide anion based on the steric hindrance effect

    NASA Astrophysics Data System (ADS)

    Chen, Guanfan; Tang, Mengzhuo; Fu, Xiufang; Cheng, Fenmin; Zou, Xianghua; Wang, Jingpei; Zeng, Rongjin

    2018-01-01

    Sulfide anions are not only generated as a byproduct from industrial processes but also as a crucial kind of element in biological systems. Therefore, fluorescent probes for detecting sulfide anion with sensitive and selective characters are highly popular. In this study, we report a highly sensitive and selective fluorescent sensor M1 for detection of sulfide anion based on the steric hindrance effect, where the recognition unit, dinitrobenzenesulfonate ester group is linked to aromatic ortho-position in the porphyrin, and correspondingly the fluorescence of fluorescein is efficiently quenched. Compared with the sensors with recognition unit linked to the other aromatic positions, the fluorescent sensor M1 has a lower fluorescence background. Furthermore, the corresponding fluorescence responses (F/F0) of M1 for mercapto amino-acid GSH, Hcy and Cys, were all far lower than the relative fluorescence ratio F/F0 values for S2-. It means that M1 is sensitive and selective to detection of S2-, and has an anti-disturbance ability to the biologically-relevant thiols, GSH, Hcy and Cys, and has the prospect of application in the exact detection of sulfide anions in living organisms. This approach offers some useful insights for realizing sensitive and selective fluorescent turn-on sensing in the detection assays for other analytes.

  19. Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.

    PubMed

    Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E

    2017-05-01

    To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.

  20. absorption sensor for sensitive temperature and species measurements in high-temperature gases

    NASA Astrophysics Data System (ADS)

    Spearrin, R. M.; Ren, W.; Jeffries, J. B.; Hanson, R. K.

    2014-09-01

    A continuous-wave laser absorption diagnostic, based on the infrared CO2 bands near 4.2 and 2.7 μm, was developed for sensitive temperature and concentration measurements in high-temperature gas systems using fixed-wavelength methods. Transitions in the respective R-branches of both the fundamental υ 3 band (~2,350 cm-1) and combination υ 1 + υ 3 band (~3,610 cm-1) were chosen based on absorption line-strength, spectral isolation, and temperature sensitivity. The R(76) line near 2,390.52 cm-1 was selected for sensitive CO2 concentration measurements, and a detection limit of <5 ppm was achieved in shock tube kinetics experiments (~1,300 K). A cross-band, two-line thermometry technique was also established utilizing the R(96) line near 2,395.14 cm-1, paired with the R(28) line near 3,633.08 cm-1. This combination yields high temperature sensitivity (ΔE" = 3,305 cm-1) and expanded range compared with previous intra-band CO2 sensors. Thermometry performance was validated in a shock tube over a range of temperatures (600-1,800 K) important for combustion. Measured temperature accuracy was demonstrated to be better than 1 % over the entire range of conditions, with a standard error of ~0.5 % and µs temporal resolution.

  1. A Normative Data Set for the Clinical Assessment of Achromatic and Chromatic Contrast Sensitivity Using a qCSF Approach.

    PubMed

    Kim, Yeon Jin; Reynaud, Alexandre; Hess, Robert F; Mullen, Kathy T

    2017-07-01

    The measurement of achromatic sensitivity has been an important tool for monitoring subtle changes in vision as the result of disease or response to therapy. In this study, we aimed to provide a normative data set for achromatic and chromatic contrast sensitivity functions within a common cone contrast space using an abbreviated measurement approach suitable for clinical practice. In addition, we aimed to provide comparisons of achromatic and chromatic binocular summation across spatial frequency. We estimated monocular cone contrast sensitivity functions (CCSFs) using a quick Contrast Sensitivity Function (qCSF) approach for achromatic as well as isoluminant, L/M cone opponent, and S cone opponent stimuli in a healthy population of 51 subjects. We determined the binocular CCSFs for achromatic and chromatic vision to evaluate the degree of binocular summation across spatial frequency for these three different mechanisms in a subset of 20 subjects. Each data set shows consistent contrast sensitivity across the population. They highlight the extremely high cone contrast sensitivity of L/M cone opponency compared with the S-cone and achromatic responses. We also find that the two chromatic sensitivities are correlated across the healthy population. In addition, binocular summation for all mechanisms depends strongly on stimulus spatial frequency. This study, using an approach well suited to the clinic, is the first to provide a comparative normative data set for the chromatic and achromatic contrast sensitivity functions, yielding quantitative comparisons of achromatic, L/M cone opponent, and S cone opponent chromatic sensitivities as a function of spatial frequency.

  2. Piezoresistive method for a laser induced shock wave detection on solids

    NASA Astrophysics Data System (ADS)

    Gonzalez-Romero, R.; Garcia-Torales, G.; Gomez Rosas, G.; Strojnik, M.

    2017-08-01

    A laser shock wave is a mechanical high-pressure impulse with a duration of a few nanoseconds induced by a high power laser pulse. We performed wave pressure measurements in order to build and check mathematical models. They are used for wave applications in material science, health, and defense, to list a few. Piezoresistive methods have been shown to be highly sensitive, linear, and highly appropriate for practical implementation, compared with piezoelectric methods employed in shock wave pressure measurements. In this work, we develop a novel method to obtain the sensitivity of a piezoresistive measurement system. The results shows that it is possible to use a mechanical method to measure pressure of a laser induced shock wave in nanosecond range. Experimental pressure measurements are presented.

  3. Association of circulating sTRAIL and high-sensitivity CRP with type 2 diabetic nephropathy and foot ulcers

    PubMed Central

    Arık, Hasan Onur; Yalcin, Arzu Didem; Gumuslu, Saadet; Genç, Gizem Esra; Turan, Adil; Sanlioglu, Ahter Dilsad

    2013-01-01

    Background Hyperglycemia is among the potent factors that may induce or facilitate apoptosis. TNF-Related Apoptosis-Inducing Factor (TRAIL) is known for its apoptotic and immunomodulatory effects that have recently been correlated with diabetes. We examined serum-soluble TRAIL (sTRAIL) and high-sensitivity CRP (hs-CRP) levels and their association with various distinct parameters in type 2 diabetic nephropathy patients with diabetic foot disease. Material/Methods Twenty-two diabetic nephropathy patients with foot ulcers were enrolled in our study. Patients had been diagnosed with diabetes at age 24±10.58 years. Circulating sTRAIL and Hs-CRP levels were compared with control values, and possible correlations were investigated with parameters such as age, Wagner’s Grade (WG), BMI, HbA1c, and creatinine. Results Serum sTRAIL levels were significantly reduced in the patient group, compared to healthy subjects. High HsCRP levels correlated with age, and WGS correlated with BMI and creatinine levels. Conclusions Significantly suppressed sTRAIL levels in diabetic nephropathy patients with foot ulcers compared to healthy controls suggest a protective role for TRAIL in the disease setting. PMID:23986130

  4. Rightward dominance in temporal high-frequency electrical asymmetry corresponds to higher resting heart rate and lower baroreflex sensitivity in a heterogeneous population.

    PubMed

    Tegeler, Charles H; Shaltout, Hossam A; Tegeler, Catherine L; Gerdes, Lee; Lee, Sung W

    2015-06-01

    Explore potential use of a temporal lobe electrical asymmetry score to discriminate between sympathetic and parasympathetic tendencies in autonomic cardiovascular regulation. 131 individuals (82 women, mean age 43.1, range 13-83) with diverse clinical conditions completed inventories for depressive (CES-D or BDI-II) and insomnia-related (ISI) symptomatology, and underwent five-minute recordings of heart rate and blood pressure, allowing calculation of heart rate variability and baroreflex sensitivity (BRS), followed by one-minute, two-channel, eyes-closed scalp recordings of brain electrical activity. A temporal lobe high-frequency (23-36 Hz) electrical asymmetry score was calculated for each subject by subtracting the average amplitude in the left temporal region from amplitude in the right temporal region, and dividing by the lesser of the two. Depressive and insomnia-related symptomatology exceeding clinical threshold levels were reported by 48% and 50% of subjects, respectively. Using a cutoff value of 5% or greater to define temporal high-frequency asymmetry, subjects with leftward compared to rightward asymmetry were more likely to report use of a sedative-hypnotic medication (42% vs. 22%, P = 0.02). Among subjects with asymmetry of 5% or greater to 30% or greater, those with rightward compared to leftward temporal high-frequency asymmetry had higher resting heart rate (≥5% asymmetry, 72.3 vs. 63.8, P = 0.004; ≥10%, 71.5 vs. 63.0, P = 0.01; ≥20%, 72.2 vs. 64.2, P = 0.05; ≥30%, 71.4 vs. 64.6, P = 0.05). Subjects with larger degrees of rightward compared to leftward temporal high-frequency asymmetry had lower baroreflex sensitivity (≥40% asymmetry, 10.6 vs. 16.4, P = 0.03; ≥50% asymmetry, 10.4 vs. 16.7, P = 0.05). In a heterogeneous population, individuals with rightward compared to leftward temporal high-frequency electrical asymmetry had higher resting heart rate and lower BRS. Two-channel recording of brain electrical activity from bilateral temporal regions appears to hold promise for further investigation as a means to assess cortical activity associated with autonomic cardiovascular regulation.

  5. A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring.

    PubMed

    Yang, Tingting; Jiang, Xin; Zhong, Yujia; Zhao, Xuanliang; Lin, Shuyuan; Li, Jing; Li, Xinming; Xu, Jianlong; Li, Zhihong; Zhu, Hongwei

    2017-07-28

    Profuse medical information about cardiovascular properties can be gathered from pulse waveforms. Therefore, it is desirable to design a smart pulse monitoring device to achieve noninvasive and real-time acquisition of cardiovascular parameters. The majority of current pulse sensors are usually bulky or insufficient in sensitivity. In this work, a graphene-based skin-like sensor is explored for pulse wave sensing with features of easy use and wearing comfort. Moreover, the adjustment of the substrate stiffness and interfacial bonding accomplish the optimal balance between sensor linearity and signal sensitivity, as well as measurement of the beat-to-beat radial arterial pulse. Compared with the existing bulky and nonportable clinical instruments, this highly sensitive and soft sensing patch not only provides primary sensor interface to human skin, but also can objectively and accurately detect the subtle pulse signal variations in a real-time fashion, such as pulse waveforms with different ages, pre- and post-exercise, thus presenting a promising solution to home-based pulse monitoring.

  6. Sigh rate during emotional transitions: More evidence for a sigh of relief.

    PubMed

    Vlemincx, Elke; Meulders, Michel; Abelson, James L

    2017-04-01

    Evidence suggests that sighs regulate stress and emotions, e.g. by facilitating relief. This study aimed to investigate sigh rates during relief. In addition, links between sighs, anxiety sensitivity and HPA-axis activity were explored. Healthy volunteers (N=29) were presented cues predicting the valence of subsequent stimuli. By sequencing cues that predicted pleasant or unpleasant stimuli with or without certainty, transitions to certain pleasantness (relief) or to certain unpleasantness (control) were created and compared to no transitions. Salivary cortisol, anxiety sensitivity and respiration were measured. Sigh frequency was significantly higher during relief than during control transitions and no transition states, and higher during control transitions than during no transition states. Sigh frequency increased with steeper cortisol declines for high anxiety sensitive persons. Results confirm a relationship between sighs and relief. In addition, results suggest that sigh frequency is importantly related to HPA-axis activity, particularly in high anxiety sensitive persons. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Maternal self-efficacy and experimentally manipulated infant difficulty effects on maternal sensory sensitivity: a signal detection analysis.

    PubMed

    Donovan, Wilberta; Leavitt, Lewis; Taylor, Nicole

    2005-09-01

    The impact of differences in maternal self-efficacy and infant difficulty on mothers' sensitivity to small changes in the fundamental frequency of an audiotaped infant's cry was explored in 2 experiments. The experiments share in common experimental manipulations of infant difficulty, a laboratory derived measure of maternal efficacy (low, moderate, and high illusory control), and the use of signal detection methodology to measure maternal sensory sensitivity. In Experiment 1 (N = 72), easy and difficult infant temperament was manipulated by varying the amount of crying (i.e., frequency of cry termination) in a simulated child-care task. In Experiment 2 (N = 51), easy and difficult infant temperament was manipulated via exposure to the solvable or unsolvable pretreatment of a learned helplessness task to mirror mothers' ability to soothe a crying infant. In both experiments, only mothers with high illusory control showed reduced sensory sensitivity under the difficult infant condition compared with the easy infant condition. Copyright 2005 APA, all rights reserved.

  8. Negative axial strain sensitivity in gold-coated eccentric fiber Bragg gratings

    PubMed Central

    Chah, Karima; Kinet, Damien; Caucheteur, Christophe

    2016-01-01

    New dual temperature and strain sensor has been designed using eccentric second-order fiber Bragg gratings produced in standard single-mode optical fiber by point-by-point direct writing technique with tight focusing of 800 nm femtosecond laser pulses. With thin gold coating at the grating location, we experimentally show that such gratings exhibit a transmitted amplitude spectrum composed by the Bragg and cladding modes resonances that extend in a wide spectral range exceeding one octave. An overlapping of the first order and second order spectrum is then observed. High-order cladding modes belonging to the first order Bragg resonance coupling are close to the second order Bragg resonance, they show a negative axial strain sensitivity (−0.55 pm/με) compared to the Bragg resonance (1.20 pm/με) and the same temperature sensitivity (10.6 pm/°C). With this well conditioned system, temperature and strain can be determined independently with high sensitivity, in a wavelength range limited to a few nanometers. PMID:27901059

  9. Orthogonally combined motion- and diffusion-sensitized driven equilibrium (OC-MDSDE) preparation for vessel signal suppression in 3D turbo spin echo imaging of peripheral nerves in the extremities.

    PubMed

    Cervantes, Barbara; Kirschke, Jan S; Klupp, Elizabeth; Kooijman, Hendrik; Börnert, Peter; Haase, Axel; Rummeny, Ernst J; Karampinos, Dimitrios C

    2018-01-01

    To design a preparation module for vessel signal suppression in MR neurography of the extremities, which causes minimal attenuation of nerve signal and is highly insensitive to eddy currents and motion. The orthogonally combined motion- and diffusion-sensitized driven equilibrium (OC-MDSDE) preparation was proposed, based on the improved motion- and diffusion-sensitized driven equilibrium methods (iMSDE and FC-DSDE, respectively), with specific gradient design and orientation. OC-MDSDE was desensitized against eddy currents using appropriately designed gradient prepulses. The motion sensitivity and vessel signal suppression capability of OC-MDSDE and its components were assessed in vivo in the knee using 3D turbo spin echo (TSE). Nerve-to-vessel signal ratios were measured for iMSDE and OC-MDSDE in 7 subjects. iMSDE was shown to be highly sensitive to motion with increasing flow sensitization. FC-DSDE showed robustness against motion, but resulted in strong nerve signal loss with diffusion gradients oriented parallel to the nerve. OC-MDSDE showed superior vessel suppression compared to iMSDE and FC-DSDE and maintained high nerve signal. Mean nerve-to-vessel signal ratios in 7 subjects were 0.40 ± 0.17 for iMSDE and 0.63 ± 0.37 for OC-MDSDE. OC-MDSDE combined with 3D TSE in the extremities allows high-near-isotropic-resolution imaging of peripheral nerves with reduced vessel contamination and high nerve signal. Magn Reson Med 79:407-415, 2018. © 2017 Wiley Periodicals, Inc. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Latest advances in confocal microscopy of skin cancers toward guiding patient care: a Mohs surgeon's review and perspective (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Nehal, Kishwer S.; Rajadhyaksha, Milind

    2016-02-01

    Latest advances in confocal microscopy of skin cancers toward guiding patient care: a Mohs surgeon's review and perspective About 350 publications worldwide have reported the ability of reflectance confocal microscopy (RCM) imaging to detect melanocytic skin lesions in vivo with specificity of 84-88% and sensitivity of 71-92%, and non-melanocytic skin lesions with specificity of 85-97% and sensitivity 100-92%. Lentigo maligna melanoma can be detected with sensitivity of 93% and specificity 82%. While the sensitivity is comparable to that of dermoscopy, the specificity is 2X superior, especially for lightly- and non-pigmented lesions. Dermoscopy combined with RCM imaging is proving to be both highly sensitive and highly specific. Recent studies have reported that the ratio of equivocal (i.e., would have been biopsied) lesions to detected melanomas dropped by ~2X when guided by dermoscopy and RCM imaging, compared to that with dermoscopy alone. Dermoscopy combined with RCM imaging is now being implemented to guide noninvasive diagnosis (to rule out malignancy and biopsy) and to also guide treatment, with promising initial impact: thus far, about 3,000 patients have been saved from biopsies of benign lesions. These are currently under follow-up monitoring. With fluorescence confocal microscopy (FCM) mosaicing, residual basal cell carcinomas can be detected in Mohs surgically excised fresh tissue ex vivo, with sensitivity of 94-97% and specificity 89-94%. FCM mosaicing is now being implemented for guiding Mohs surgery. To date, about 600 Mohs procedures have been performed, guided with mosaicing, and with pathology being performed in parallel to confirm the final outcome. These latest advances demonstrate the promising ability of RCM and FCM to guide patient care.

  11. Diagnostic markers for the detection of ovarian cancer in BRCA1 mutation carriers

    PubMed Central

    Weingartshofer, Sigrid; Rappaport-Fürhauser, Christine; Zeilinger, Robert; Pils, Dietmar; Muhr, Daniela; Braicu, Elena I.; Kastner, Marie-Therese; Tan, Yen Y.; Semmler, Lorenz; Sehouli, Jalid; Singer, Christian F.

    2017-01-01

    Background Screening for ovarian cancer (OC) in women at high risk consists of a combination of carbohydrate antigen 125 (CA125) and transvaginal ultrasound, despite their low sensitivity and specificity. This could be improved by the combination of several biomarkers, which has been shown in average risk patients but has not been investigated until now in female BRCA mutation carriers. Methods Using a multiplex, bead-based, immunoassay system, we analyzed the concentrations of leptin, prolactin, osteopontin, insulin-like growth factor II, macrophage inhibitory factor, CA125 and human epididymis antigen 4 in 26 healthy wild type women, 26 healthy BRCA1 mutation carriers, 28 wildtype OC patients and 26 OC patients with BRCA1 mutation. Results Using the ROC analysis, we found a high overall sensitivity of 94.3% in differentiating healthy controls from OC patients with comparable results in the wildtype subgroup (sensitivity 92.8%, AUC = 0.988; p = 5.2e-14) as well as in BRCA1 mutation carriers (sensitivity 95.2%, AUC = 0.978; p = 1.7e-15) at an overall specificity of 92.3%. The used algorithm also allowed to identify healthy BRCA1 mutation carriers when compared to healthy wildtype women (sensitivity 88.4%, specificity 80.7%, AUC = 0.895; p = 6e-08), while this was less pronounced in patients with OC (sensitivity 66.7%, specificity 67.8%, AUC = 0.724; p = 0.00065). Conclusion We have developed an algorithm, which can differentiate between healthy women and OC patients and have for the first time shown, that such an algorithm can also be used in BRCA mutation carriers. To clarify a suggested benefit to the existing early detection program, large prospective trials with mainly early stage OC cases are warranted. PMID:29244844

  12. Optimal CINAHL search strategies for identifying therapy studies and review articles.

    PubMed

    Wong, Sharon S L; Wilczynski, Nancy L; Haynes, R Brian

    2006-01-01

    To design optimal search strategies for locating sound therapy studies and review articles in CiNAHL in the year 2000. An analytic survey was conducted, comparing hand searches of 75 journals with retrievals from CINAHL for 5,020 candidate search terms and 17,900 combinations for therapy and 5,977 combinations for review articles. All articles were rated with purpose and quality indicators. Candidate search strategies were used in CINAHL, and the retrievals were compared with results of the hand searches. The proposed search strategies were treated as "diagnostic tests" for sound studies and the manual review of the literature was treated as the "gold standard." Operating characteristics of the search strategies were calculated. Of the 1,383 articles about treatment, 506 (36.6%) met basic criteria for scientific merit and 127 (17.9%) of the 711 articles classified as a review met the criteria for systematic reviews. For locating sound treatment studies, a three-term strategy maximized sensitivity at 99.4% but with compromised specificity at 58.3%, and a two-term strategy maximized specificity at 98.5% but with compromised sensitivity at 52.0%. For detecting systematic reviews, a three-term strategy maximized sensitivity at 91.3% while keeping specificity high at 95.4%, and a single-term strategy maximized specificity at 99.6% but with compromised sensitivity at 42.5%. Three-term search strategies optimizing sensitivity and specificity achieved these values over 91% for detecting sound treatment studies and over 76% for detecting systematic reviews. Search strategies combining indexing terms and text words can achieve high sensitivity and specificity for retrieving sound treatment studies and review articles in CINAHL.

  13. Effect of electrode material and design on sensitivity and selectivity for high temperature impedancemetric NOx sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woo, L Y; Glass, R S; Novak, R F

    2009-09-23

    Solid-state electrochemical sensors using two different sensing electrode compositions, gold and strontium-doped lanthanum manganite (LSM), were evaluated for gas phase sensing of NO{sub x} (NO and NO{sub 2}) using an impedance-metric technique. An asymmetric cell design utilizing porous YSZ electrolyte exposed both electrodes to the test gas (i.e., no reference gas). Sensitivity to less than 5 ppm NO and response/recovery times (10-90%) less than 10 s were demonstrated. Using an LSM sensing electrode, virtual identical sensitivity towards NO and NO{sub 2} was obtained, indicating that the equilibrium gas concentration was measured by the sensing electrode. In contrast, for cells employingmore » a gold sensing electrode the NO{sub x} sensitivity varied depending on the cell design: increasing the amount of porous YSZ electrolyte on the sensor surface produced higher NO{sub 2} sensitivity compared to NO. In order to achieve comparable sensitivity for both NO and NO{sub 2}, the cell with the LSM sensing electrode required operation at a lower temperature (575 C) than the cell with the gold sensing electrode (650 C). The role of surface reactions are proposed to explain the differences in NO and NO{sub 2} selectivity using the two different electrode materials.« less

  14. Ultrasound Fracture Diagnosis in Space

    NASA Technical Reports Server (NTRS)

    Dulchavsky, Scott A.; Amponsah, David; Sargsyan, Ashot E.; Garcia, Kathleen M.; Hamilton, Douglas R.; vanHolsbeeck, Marnix

    2010-01-01

    Introduction: This ground-based investigation accumulated high-level clinical evidence on the sensitivity and specificity of point of care ultrasound performed by expert and novice users for the rapid diagnosis of musculoskeletal (MSK) injuries. We developed preliminary educational methodologies to provide just-in-time training of novice users by creating multi-media training tools and imaging procedures for non expert operators and evaluated the sensitivity and specificity of non-expert performed musculoskeletal ultrasound to diagnose acute injuries in a Level 1 Trauma Center. Methods: Patients with potential MSK injuries were identified in the emergency room. A focused MSK ultrasound was performed by expert operators and compared to standard radiographs. A repeat examination was performed by non-expert operators who received a short, just-in-time multimedia education aid. The sensitivity and specificity of the expert and novice ultrasound examinations were compared to gold standard radiography. Results: Over 800 patients were enrolled in this study. The sensitivity and specificity of expert performed ultrasound exceeded 98% for MSK injuries. Novice operators achieved 97% sensitivity and 99% specificity for targeted examinations with the greatest error in fractures involving the hand and foot. Conclusion: Point of care ultrasound is a sensitive and specific diagnostic test for MSK injury when performed by experts and just-in-time trained novice operators.

  15. Transverse slot antennas for high field MRI

    PubMed Central

    Lattanzi, Riccardo; Lakshmanan, Karthik; Brown, Ryan; Deniz, Cem M.; Sodickson, Daniel K.; Collins, Christopher M.

    2018-01-01

    Purpose Introduce a novel coil design using an electrically long transversely oriented slot in a conductive sheet. Theory and Methods Theoretical considerations, numerical simulations, and experimental measurements are presented for transverse slot antennas as compared with electric dipole antennas. Results Simulations show improved central and average transmit and receive efficiency, as well as larger coverage in the transverse plane, for a single slot as compared to a single dipole element. Experiments on a body phantom confirm the simulation results for a slot antenna relative to a dipole, demonstrating a large region of relatively high sensitivity and homogeneity. Images in a human subject also show a large imaging volume for a single slot and six slot antenna array. High central transmit efficiency was observed for slot arrays relative to dipole arrays. Conclusion Transverse slots can exhibit improved sensitivity and larger field of view compared with traditional conductive dipoles. Simulations and experiments indicate high potential for slot antennas in high field MRI. Magn Reson Med 80:1233–1242, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. PMID:29388250

  16. Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.

    PubMed

    Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S

    2013-01-01

    To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.

  17. Pulse-shape discrimination between electron and nuclear recoils in a NaI(Tl) crystal

    NASA Astrophysics Data System (ADS)

    Lee, H. S.; Adhikari, G.; Adhikari, P.; Choi, S.; Hahn, I. S.; Jeon, E. J.; Joo, H. W.; Kang, W. G.; Kim, G. B.; Kim, H. J.; Kim, H. O.; Kim, K. W.; Kim, N. Y.; Kim, S. K.; Kim, Y. D.; Kim, Y. H.; Lee, J. H.; Lee, M. H.; Leonard, D. S.; Li, J.; Oh, S. Y.; Olsen, S. L.; Park, H. K.; Park, H. S.; Park, K. S.; Shim, J. H.; So, J. H.

    2015-08-01

    We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton-scattered 662 keV γ-rays from a 137Cs source. The measured pulse-shape discrimination (PSD) power of the NaI(Tl) crystal is found to be significantly improved because of the high light output of the NaI(Tl) detector. We quantify the PSD power with a quality factor and estimate the sensitivity to the interaction rate for weakly interacting massive particles (WIMPs) with nucleons, and the result is compared with the annual modulation amplitude observed by the DAMA/LIBRA experiment. The sensitivity to spin-independent WIMP-nucleon interactions based on 100 kg·year of data from NaI detectors is estimated with simulated experiments, using the standard halo model.

  18. Parahydrogen-enhanced zero-field nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Theis, T.; Ganssle, P.; Kervern, G.; Knappe, S.; Kitching, J.; Ledbetter, M. P.; Budker, D.; Pines, A.

    2011-07-01

    Nuclear magnetic resonance, conventionally detected in magnetic fields of several tesla, is a powerful analytical tool for the determination of molecular identity, structure and function. With the advent of prepolarization methods and detection schemes using atomic magnetometers or superconducting quantum interference devices, interest in NMR in fields comparable to the Earth's magnetic field and below (down to zero field) has been revived. Despite the use of superconducting quantum interference devices or atomic magnetometers, low-field NMR typically suffers from low sensitivity compared with conventional high-field NMR. Here we demonstrate direct detection of zero-field NMR signals generated through parahydrogen-induced polarization, enabling high-resolution NMR without the use of any magnets. The sensitivity is sufficient to observe spectra exhibiting 13C-1H scalar nuclear spin-spin couplings (known as J couplings) in compounds with 13C in natural abundance, without the need for signal averaging. The resulting spectra show distinct features that aid chemical fingerprinting.

  19. Defect inspection and printability study for 14 nm node and beyond photomask

    NASA Astrophysics Data System (ADS)

    Seki, Kazunori; Yonetani, Masashi; Badger, Karen; Dechene, Dan J.; Akima, Shinji

    2016-10-01

    Two different mask inspection techniques are developed and compared for 14 nm node and beyond photomasks, High resolution and Litho-based inspection. High resolution inspection is the general inspection method in which a 19x nm wavelength laser is used with the High NA inspection optics. Litho-based inspection is a new inspection technology. This inspection uses the wafer lithography information, and as such, this method has automatic defect classification capability which is based on wafer printability. Both High resolution and Litho-based inspection methods are compared using 14 nm and 7 nm node programmed defect and production design masks. The defect sensitivity and mask inspectability is compared, in addition to comparing the defect classification and throughput. Additionally, the Cost / Infrastructure comparison is analyzed and the impact of each inspection method is discussed.

  20. Testing for developmental neurotoxicity using a battery of in vitro assays for key cellular events in neurodevelopment.

    PubMed

    Harrill, Joshua A; Freudenrich, Theresa; Wallace, Kathleen; Ball, Kenneth; Shafer, Timothy J; Mundy, William R

    2018-04-05

    Medium- to high-throughput in vitro assays that recapitulate the critical processes of nervous system development have been proposed as a means to facilitate rapid testing and identification of chemicals which may affect brain development. In vivo neurodevelopment is a complex progression of distinct cellular processes. Therefore, batteries of in vitro assays that model and quantify effects on a variety of neurodevelopmental processes have the potential to identify chemicals which may affect brain development at different developmental stages. In the present study, the results of concentration-response screening of 67 reference chemicals in a battery of high content imaging and microplate reader-based assays that evaluate neural progenitor cell proliferation, neural proginitor cell apoptosis, neurite initiation/outgrowth, neurite maturation and synaptogenesis are summarized and compared. The assay battery had a high degree of combined sensitivity (87%) for categorizing chemicals known to affect neurodevelopment as active and a moderate degree of combined specificity (71%) for categorizing chemicals not associated with affects on neurodevelopment as inactive. The combined sensitivity of the assay battery was higher compared to any individual assay while the combined specificity of the assay battery was lower compared to any individual assay. When selectivity of effects for a neurodevelopmental endpoint as compared to general cytotoxicity was taken into account, the combined sensitivity of the assay battery decreased (68%) while the combined specificity increased (93%). The identity and potency of chemicals identified as active varied across the assay battery, underscoring the need for use of a combination of diverse in vitro models to comprehensively screen chemicals and identify those which potentially affect neurodevelopment. Overall, these data indicate that a battery of assays which address many different processes in nervous system development may be used to identify potential developmental neurotoxicants and to distinguish specific from generalized cytotoxic effects with a high degree of success. Published by Elsevier Inc.

  1. Responses to auxin signals: an operating principle for dynamical sensitivity yet high resilience

    PubMed Central

    Bravi, B.; Martin, O. C.

    2018-01-01

    Plants depend on the signalling of the phytohormone auxin for their development and for responding to environmental perturbations. The associated biomolecular signalling network involves a negative feedback on Aux/IAA proteins which mediate the influence of auxin (the signal) on the auxin response factor (ARF) transcription factors (the drivers of the response). To probe the role of this feedback, we consider alternative in silico signalling networks implementing different operating principles. By a comparative analysis, we find that the presence of a negative feedback allows the system to have a far larger sensitivity in its dynamical response to auxin and that this sensitivity does not prevent the system from being highly resilient. Given this insight, we build a new biomolecular signalling model for quantitatively describing such Aux/IAA and ARF responses. PMID:29410878

  2. Pain sensitivity and temperament in extremely low-birth-weight premature toddlers and preterm and full-term controls.

    PubMed

    Grunau, R V; Whitfield, M F; Petrie, J H

    1994-09-01

    High-technology medical care of extremely low-birth-weight (ELBW) infants (< 1001 g) involves repeated medical interventions which are potentially painful and may later affect reaction to pain. At 18 months corrected age (CCA), we examined parent ratings of pain sensitivity and how pain sensitivity ratings related to child temperament and parenting style in 2 groups of ELBW children (49 with a birth weight of 480-800 g and 75 with a birth weight of 801-1000 g) and 2 control groups (42 heavier preterm (1500-2499 g) and 29 full-birth-weight (FBW) children (> 2500 g). Both groups of ELBW toddlers were rated by parents as significantly lower in pain sensitivity compared with both control groups. The relationships between child temperament and pain sensitivity rating varied systematically across the groups. Temperament was strongly related to rated pain sensitivity in the FBW group, moderately related in the heavier preterm and ELBW 801-1000 g groups, and not related in the lowest birth-weight group (< 801 g). Parental style did not mediate ratings of pain sensitivity. The results suggest that parents perceive differences in pain behavior of ELBW toddlers compared with heavier preterm and FBW toddlers, especially for those less than 801 g. Longitudinal research into the development of pain behavior for infants who experience lengthy hospitalization is warranted.

  3. Sensitivity to psychostimulants in mice bred for high and low stimulation to methamphetamine.

    PubMed

    Kamens, H M; Burkhart-Kasch, S; McKinnon, C S; Li, N; Reed, C; Phillips, T J

    2005-03-01

    Methamphetamine (MA) and cocaine induce behavioral effects primarily through modulation of dopamine neurotransmission. However, the genetic regulation of sensitivity to these two drugs may be similar or disparate. Using selective breeding, lines of mice were produced with extreme sensitivity (high MA activation; HMACT) and insensitivity (low MA activation; LMACT) to the locomotor stimulant effects of acute MA treatment. Studies were performed to determine whether there is pleiotropic genetic influence on sensitivity to the locomotor stimulant effect of MA and to other MA- and cocaine-related behaviors. The HMACT line exhibited more locomotor stimulation in response to several doses of MA and cocaine, compared to the LMACT line. Both lines exhibited locomotor sensitization to 2 mg/kg of MA and 10 mg/kg of cocaine; the magnitude of sensitization was similar in the two lines. However, the lines differed in the magnitude of sensitization to a 1 mg/kg dose of MA, a dose that did not produce a ceiling effect that may confound interpretation of studies using higher doses. The LMACT line consumed more MA and cocaine in a two-bottle choice drinking paradigm; the lines consumed similar amounts of saccharin and quinine, although the HMACT line exhibited slightly elevated preference for a low concentration of saccharin. These results suggest that some genes that influence sensitivity to the acute locomotor stimulant effect of MA have a pleiotropic influence on the magnitude of behavioral sensitization to MA and sensitivity to the stimulant effects of cocaine. Further, extreme sensitivity to MA may protect against MA and cocaine self-administration.

  4. Highly Sensitive and Automated Surface Enhanced Raman Scattering-based Immunoassay for H5N1 Detection with Digital Microfluidics.

    PubMed

    Wang, Yang; Ruan, Qingyu; Lei, Zhi-Chao; Lin, Shui-Chao; Zhu, Zhi; Zhou, Leiji; Yang, Chaoyong

    2018-04-17

    Digital microfluidics (DMF) is a powerful platform for a broad range of applications, especially immunoassays having multiple steps, due to the advantages of low reagent consumption and high automatization. Surface enhanced Raman scattering (SERS) has been proven as an attractive method for highly sensitive and multiplex detection, because of its remarkable signal amplification and excellent spatial resolution. Here we propose a SERS-based immunoassay with DMF for rapid, automated, and sensitive detection of disease biomarkers. SERS tags labeled with Raman reporter 4-mercaptobenzoic acid (4-MBA) were synthesized with a core@shell nanostructure and showed strong signals, good uniformity, and high stability. A sandwich immunoassay was designed, in which magnetic beads coated with antibodies were used as solid support to capture antigens from samples to form a beads-antibody-antigen immunocomplex. By labeling the immunocomplex with a detection antibody-functionalized SERS tag, antigen can be sensitively detected through the strong SERS signal. The automation capability of DMF can greatly simplify the assay procedure while reducing the risk of exposure to hazardous samples. Quantitative detection of avian influenza virus H5N1 in buffer and human serum was implemented to demonstrate the utility of the DMF-SERS method. The DMF-SERS method shows excellent sensitivity (LOD of 74 pg/mL) and selectivity for H5N1 detection with less assay time (<1 h) and lower reagent consumption (∼30 μL) compared to the standard ELISA method. Therefore, this DMF-SERS method holds great potentials for automated and sensitive detection of a variety of infectious diseases.

  5. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor.

    PubMed

    Dong, Yan; Son, Dong-Hyeok; Dai, Quan; Lee, Jun-Hyeok; Won, Chul-Ho; Kim, Jeong-Gil; Chen, Dunjun; Lee, Jung-Hee; Lu, Hai; Zhang, Rong; Zheng, Youdou

    2018-04-24

    The AlInN/GaN high-electron-mobility-transistor (HEMT) indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al 0.83 In 0.17 N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN) and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG) density and a thinner barrier layer in Al 0.83 In 0.17 N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  6. High elevation watersheds in the southern Appalachians: indicators of sensitivity to acidic deposition and the potential for restoration through liming

    Treesearch

    Jennifer D. Knoepp; James M. Vose; William A. Jackson; Katherine J. Elliott; Stan Zarnoch

    2016-01-01

    Southern Appalachian high elevation watersheds have deep rocky soils with high organic matter content, different vegetation communities, and receive greater inputs of acidic deposition compared to low elevation sites within the region. Since the implementation of the Clean Air Act Amendment in the 1990s, concentrations of acidic anions in rainfall have...

  7. Cognitive and Neural Bases of Skilled Performance.

    DTIC Science & Technology

    1987-10-04

    advantage is that this method is not computationally demanding, and model -specific analyses such as high -precision source localization with realistic...and a two- < " high -threshold model satisfy theoretical and pragmatic independence. Discrimination and bias measures from these two models comparing...recognition memory of patients with dementing diseases, amnesics, and normal controls. We found the two- high -threshold model to be more sensitive Lloyd

  8. Comparative evaluation of workload estimation techniques in piloting tasks

    NASA Technical Reports Server (NTRS)

    Wierwille, W. W.

    1983-01-01

    Techniques to measure operator workload in a wide range of situations and tasks were examined. The sensitivity and intrusion of a wide variety of workload assessment techniques in simulated piloting tasks were investigated. Four different piloting tasks, psychomotor, perceptual, mediational, and communication aspects of piloting behavior were selected. Techniques to determine relative sensitivity and intrusion were applied. Sensitivity is the relative ability of a workload estimation technique to discriminate statistically significant differences in operator loading. High sensitivity requires discriminable changes in score means as a function of load level and low variation of the scores about the means. Intrusion is an undesirable change in the task for which workload is measured, resulting from the introduction of the workload estimation technique or apparatus.

  9. Greater perceptual sensitivity to happy facial expression.

    PubMed

    Maher, Stephen; Ekstrom, Tor; Chen, Yue

    2014-01-01

    Perception of subtle facial expressions is essential for social functioning; yet it is unclear if human perceptual sensitivities differ in detecting varying types of facial emotions. Evidence diverges as to whether salient negative versus positive emotions (such as sadness versus happiness) are preferentially processed. Here, we measured perceptual thresholds for the detection of four types of emotion in faces--happiness, fear, anger, and sadness--using psychophysical methods. We also evaluated the association of the perceptual performances with facial morphological changes between neutral and respective emotion types. Human observers were highly sensitive to happiness compared with the other emotional expressions. Further, this heightened perceptual sensitivity to happy expressions can be attributed largely to the emotion-induced morphological change of a particular facial feature (end-lip raise).

  10. Influence of enrichment broths on multiplex PCR detection of total coliform bacteria, Escherichia coli and Clostridium perfringens, in spiked water samples.

    PubMed

    Worakhunpiset, S; Tharnpoophasiam, P

    2009-07-01

    Although multiplex PCR amplification condition for simultaneous detection of total coliform bacteria, Escherichia coli and Clostridium perfringens in water sample has been developed, results with high sensitivity are obtained when amplifying purified DNA, but the sensitivity is low when applied to spiked water samples. An enrichment broth culture prior PCR analysis increases sensitivity of the test but the specific nature of enrichment broth can affect the PCR results. Three enrichment broths, lactose broth, reinforced clostridial medium and fluid thioglycollate broth, were compared for their influence on sensitivity and on time required with multiplex PCR assay. Fluid thioglycollate broth was the most effective with shortest enrichment time and lowest detection limit.

  11. Dermal safety assessment of Arm & Hammer laundry products formulated for sensitive skin.

    PubMed

    Frederick, Douglas M; Vorwerk, Linda; Gupta, Archana; Ghassemi, Annahita

    2017-09-01

    The prevalence of sensitive skin among the general population in industrialized countries is reported to be over 50%. Sensitive skin subjects often report significant reactions to contact with cosmetics, soaps and other consumer products. This paper describes the overall skin compatibility and mildness program for a newly developed, lightly fragranced, colorant free laundry product (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent), specially formulated for individuals with sensitive skin. The skin mildness of the product was compared to Arm & Hammer™ Free & Clear liquid laundry detergent with no fragrance or colorant, and an established history of safe use by sensitive skin consumers. The test material was a liquid laundry product with a light scent formulated for sensitive skin consumers (Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent). The product was compared to commercially marketed products for sensitive skin with a history of skin safety in the marketplace, including: a very similar product formulation (Arm & Hammer™ Free & Clear with no fragrance), and several selected competitors' products. Studies were conducted among individuals with self-assessed sensitive skin (based on a questionnaire) using standard protocols for the Human Repeat Insult Patch Test (HRIPT), 10-Day Cumulative Irritation, the Wrist Band Wear test, and the Safety In-Use testing. Responses in all protocols were evaluated by visual scoring of potential dermatologic reactions, and recording any sensory effects at the time of the examination. In addition, sensory effects collected from panelists' daily diaries were also evaluated. The HRIPT confirmed that neither the fragrance alone, nor the product formulation with fragrance, induced contact sensitization in sensitive skin subjects. The 10-Day cumulative irritation study conducted using sensitive skin subjects showed highly favorable skin compatibility, and the test product was comparable to the control product (Arm & Hammer Free & Clear) and other nonirritant controls. In the Wrist Band Wear test, exposure to laundered fabrics under exaggerated conditions gave similar results for the test and control products, with no objective signs of skin irritation, and no self-reported persistent adverse sensory effects. Very mild, transient and isolated sensory effects were noted in daily diaries by a small proportion of subjects, and were similar for the test and control products. The Safety In-Use tests evaluated 4-week exposure to product and laundered fabrics under realistic use conditions. There were no clinically objective signs of skin irritation, and reports of transitory, mild sensory effects were minimal and similar for the test and controls. A comprehensive skin safety program on a lightly scented sensitive skin laundry formulation (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent) conducted among panels of self-assessed sensitive skin subjects demonstrated that the presence of a light fragrance did not adversely impact skin compatibility in any of the testing protocols when the product was compared to a similar product with no fragrance. The lightly fragranced product demonstrated overall skin compatibility and mildness when tested in a self-assessed sensitive skin population, and compared favorably to currently marketed sensitive skin products.

  12. Hot and steady: Elevated temperatures do not enhance muscle disuse atrophy during prolonged aestivation in the ectotherm Cyclorana alboguttata.

    PubMed

    Young, K M; Cramp, R L; Franklin, C E

    2013-02-01

    Animals that undergo prolonged dormancy experience minimal muscle disuse atrophy (MDA) compared to animals subjected to artificial immobilisation over shorter timeframes. An association between oxidative stress and MDA suggests that metabolic depression presumably affords dormant animals some protection against muscle disuse. Because aerobic metabolism is temperature sensitive, we proposed that MDA in dormant (aestivating) ectotherms would be enhanced at elevated temperatures. In the green-striped burrowing frog, Cyclorana alboguttata, the thermal sensitivity of skeletal muscle metabolic rate is muscle-specific. We proposed that the degree of atrophy experienced during aestivation would correlate with the thermal sensitivity of muscle metabolic rate such that muscles with a relatively high metabolic rate at high temperatures would experience more disuse atrophy. To test this hypothesis, we examined the effect of temperature and aestivation on the extent of MDA in two functionally different muscles: the M. gastrocnemius (jumping muscle) and M. iliofibularis (non-jumping muscle), in C. alboguttata aestivating at 24 or 30 °C for 6 months. We compared a range of morphological parameters from muscle cross-sections stained with succinic dehydrogenase to show that muscle-specific patterns of disuse atrophy were consistent with the relative rates of oxygen consumption of those muscle types. However, despite muscle-specific differences in thermal sensitivity of metabolic rate, aestivation temperature did not influence the extent of atrophy in either muscle. Our results suggest that the muscles of frogs aestivating at high temperatures are defended against additional atrophy ensuring protection of muscle function during long periods of immobilisation. Copyright © 2012 Wiley Periodicals, Inc.

  13. Nuclear morphology for the detection of alterations in bronchial cells from lung cancer: an attempt to improve sensitivity and specificity.

    PubMed

    Fafin-Lefevre, Mélanie; Morlais, Fabrice; Guittet, Lydia; Clin, Bénédicte; Launoy, Guy; Galateau-Sallé, Françoise; Plancoulaine, Benoît; Herlin, Paulette; Letourneux, Marc

    2011-08-01

    To identify which morphologic or densitometric parameters are modified in cell nuclei from bronchopulmonary cancer based on 18 parameters involving shape, intensity, chromatin, texture, and DNA content and develop a bronchopulmonary cancer screening method relying on analysis of sputum sample cell nuclei. A total of 25 sputum samples from controls and 22 bronchial aspiration samples from patients presenting with bronchopulmonary cancer who were professionally exposed to cancer were used. After Feulgen staining, 18 morphologic and DNA content parameters were measured on cell nuclei, via image cytom- etry. A method was developed for analyzing distribution quantiles, compared with simply interpreting mean values, to characterize morphologic modifications in cell nuclei. Distribution analysis of parameters enabled us to distinguish 13 of 18 parameters that demonstrated significant differences between controls and cancer cases. These parameters, used alone, enabled us to distinguish two population types, with both sensitivity and specificity > 70%. Three parameters offered 100% sensitivity and specificity. When mean values offered high sensitivity and specificity, comparable or higher sensitivity and specificity values were observed for at least one of the corresponding quantiles. Analysis of modification in morphologic parameters via distribution analysis proved promising for screening bronchopulmonary cancer from sputum.

  14. Thrombomodulin as a marker for vascular tumors. Comparative study with factor VIII and Ulex europaeus I lectin.

    PubMed

    Yonezawa, S; Maruyama, I; Sakae, K; Igata, A; Majerus, P W; Sato, E

    1987-10-01

    Thrombomodulin (TM) is a newly described endothelial cell-associated protein that functions as a potent natural anticoagulant by converting thrombin from a procoagulant protease to an anticoagulant. Various vascular tumors were characterized with immunoperoxidase staining with the use of a polyclonal anti-TM serum. The staining patterns of TM were compared with those of Factor VIII-related antigen (FVIII-RAG) and Ulex europaeus agglutinin-I (UEA-I), which have been used as markers for endothelial cells. The results showed that TM is a specific and a highly sensitive marker for angiosarcomas in comparison with FVIII-RAG or UEA-I. In contrast, UEA-I is more sensitive for benign vascular tumors than TM or FVIII-RAG. The other mesenchymal tumors of nonvascular origin showed negative staining for three endothelial markers. These results indicate that TM is a new specific and sensitive tool for the diagnosis of angiosarcomas.

  15. Comparison of randomly cloned and whole genomic DNA probes for the detection of Porphyromonas gingivalis and Bacteroides forsythus

    PubMed Central

    Wong, M.; DiRienzo, J.M.; Lai, C.-H.; Listgarten, M. A.

    2012-01-01

    Whole genomic and randomly-cloned DNA probes for two fastidious periodontal pathogens, Porphyromonas gingivalis and Bacteroides forsythus were labeled with digoxigenin and detected by a colorimetric method. The specificity and sensitivity of the whole genomic and cloned probes were compared. The cloned probes were highly specific compared to the whole genomic probes. A significant degree of cross-reactivity with Bacteroides species. Capnocytophaga sp. and Prevotella sp. was observed with the whole genomic probes. The cloned probes were less sensitive than the whole genomic probes and required at least 106 target cells or a minimum of 10 ng of target DNA to be detected during hybridization. Although a ten-fold increase in sensitivity was obtained with the whole genomic probes, cross-hybridization to closely related species limits their reliability in identifying target bacteria in subgingival plaque samples. PMID:8636873

  16. High-sensitivity explosives detection using dual-excitation-wavelength resonance-Raman detector

    NASA Astrophysics Data System (ADS)

    Yellampalle, Balakishore; McCormick, William B.; Wu, Hai-Shan; Sluch, Mikhail; Martin, Robert; Ice, Robert V.; Lemoff, Brian

    2014-05-01

    A key challenge for standoff explosive sensors is to distinguish explosives, with high confidence, from a myriad of unknown background materials that may have interfering spectral peaks. To meet this challenge a sensor needs to exhibit high specificity and high sensitivity in detection at low signal-to-noise ratio levels. We had proposed a Dual-Excitation- Wavelength Resonance-Raman Detector (DEWRRED) to address this need. In our previous work, we discussed various components designed at WVHTCF for a DEWRRED sensor. In this work, we show a completely assembled laboratory prototype of a DEWRRED sensor and utilize it to detect explosives from two standoff distances. The sensor system includes two novel, compact CW deep-Ultraviolet (DUV) lasers, a compact dual-band high throughput DUV spectrometer, and a highly-sensitive detection algorithm. We choose DUV excitation because Raman intensities from explosive traces are enhanced and fluorescence and solar background are not present. The DEWRRED technique exploits the excitation wavelength dependence of Raman signal strength, arising from complex interplay of resonant enhancement, self-absorption and laser penetration depth. We show measurements from >10 explosives/pre-cursor materials at different standoff distances. The sensor showed high sensitivity in explosive detection even when the signalto- noise ratio was close to one (~1.6). We measured receiver-operating-characteristics, which show a clear benefit in using the dual-excitation-wavelength technique as compared to a single-excitation-wavelength technique. Our measurements also show improved specificity using the amplitude variation information in the dual-excitation spectra.

  17. Regional Community Climate Simulations with variable resolution meshes in the Community Earth System Model

    NASA Astrophysics Data System (ADS)

    Zarzycki, C. M.; Gettelman, A.; Callaghan, P.

    2017-12-01

    Accurately predicting weather extremes such as precipitation (floods and droughts) and temperature (heat waves) requires high resolution to resolve mesoscale dynamics and topography at horizontal scales of 10-30km. Simulating such resolutions globally for climate scales (years to decades) remains computationally impractical. Simulating only a small region of the planet is more tractable at these scales for climate applications. This work describes global simulations using variable-resolution static meshes with multiple dynamical cores that target the continental United States using developmental versions of the Community Earth System Model version 2 (CESM2). CESM2 is tested in idealized, aquaplanet and full physics configurations to evaluate variable mesh simulations against uniform high and uniform low resolution simulations at resolutions down to 15km. Different physical parameterization suites are also evaluated to gauge their sensitivity to resolution. Idealized variable-resolution mesh cases compare well to high resolution tests. More recent versions of the atmospheric physics, including cloud schemes for CESM2, are more stable with respect to changes in horizontal resolution. Most of the sensitivity is due to sensitivity to timestep and interactions between deep convection and large scale condensation, expected from the closure methods. The resulting full physics model produces a comparable climate to the global low resolution mesh and similar high frequency statistics in the high resolution region. Some biases are reduced (orographic precipitation in the western United States), but biases do not necessarily go away at high resolution (e.g. summertime JJA surface Temp). The simulations are able to reproduce uniform high resolution results, making them an effective tool for regional climate studies and are available in CESM2.

  18. Concept Study of Optical Configurations for High-Frequency Telescope for LiteBIRD

    NASA Astrophysics Data System (ADS)

    Hasebe, T.; Kashima, S.; Ade, P. A. R.; Akiba, Y.; Alonso, D.; Arnold, K.; Aumont, J.; Baccigalupi, C.; Barron, D.; Basak, S.; Beckman, S.; Borrill, J.; Boulanger, F.; Bucher, M.; Calabrese, E.; Chinone, Y.; Cho, H.-M.; Cukierman, A.; Curtis, D. W.; de Haan, T.; Dobbs, M.; Dominjon, A.; Dotani, T.; Duband, L.; Ducout, A.; Dunkley, J.; Duval, J. M.; Elleflot, T.; Eriksen, H. K.; Errard, J.; Fischer, J.; Fujino, T.; Funaki, T.; Fuskeland, U.; Ganga, K.; Goeckner-Wald, N.; Grain, J.; Halverson, N. W.; Hamada, T.; Hasegawa, M.; Hattori, K.; Hattori, M.; Hayes, L.; Hazumi, M.; Hidehira, N.; Hill, C. A.; Hilton, G.; Hubmayr, J.; Ichiki, K.; Iida, T.; Imada, H.; Inoue, M.; Inoue, Y.; Irwin, K. D.; Ishino, H.; Jeong, O.; Kanai, H.; Kaneko, D.; Katayama, N.; Kawasaki, T.; Kernasovskiy, S. A.; Keskitalo, R.; Kibayashi, A.; Kida, Y.; Kimura, K.; Kisner, T.; Kohri, K.; Komatsu, E.; Komatsu, K.; Kuo, C. L.; Kurinsky, N. A.; Kusaka, A.; Lazarian, A.; Lee, A. T.; Li, D.; Linder, E.; Maffei, B.; Mangilli, A.; Maki, M.; Matsumura, T.; Matsuura, S.; Meilhan, D.; Mima, S.; Minami, Y.; Mitsuda, K.; Montier, L.; Nagai, M.; Nagasaki, T.; Nagata, R.; Nakajima, M.; Nakamura, S.; Namikawa, T.; Naruse, M.; Nishino, H.; Nitta, T.; Noguchi, T.; Ogawa, H.; Oguri, S.; Okada, N.; Okamoto, A.; Okamura, T.; Otani, C.; Patanchon, G.; Pisano, G.; Rebeiz, G.; Remazeilles, M.; Richards, P. L.; Sakai, S.; Sakurai, Y.; Sato, Y.; Sato, N.; Sawada, M.; Segawa, Y.; Sekimoto, Y.; Seljak, U.; Sherwin, B. D.; Shimizu, T.; Shinozaki, K.; Stompor, R.; Sugai, H.; Sugita, H.; Suzuki, A.; Suzuki, J.; Tajima, O.; Takada, S.; Takaku, R.; Takakura, S.; Takatori, S.; Tanabe, D.; Taylor, E.; Thompson, K. L.; Thorne, B.; Tomaru, T.; Tomida, T.; Tomita, N.; Tristram, M.; Tucker, C.; Turin, P.; Tsujimoto, M.; Uozumi, S.; Utsunomiya, S.; Uzawa, Y.; Vansyngel, F.; Wehus, I. K.; Westbrook, B.; Willer, M.; Whitehorn, N.; Yamada, Y.; Yamamoto, R.; Yamasaki, N.; Yamashita, T.; Yoshida, M.

    2018-05-01

    The high-frequency telescope for LiteBIRD is designed with refractive and reflective optics. In order to improve sensitivity, this paper suggests the new optical configurations of the HFT which have approximately 7 times larger focal planes than that of the original design. The sensitivities of both the designs are compared, and the requirement of anti-reflection (AR) coating on the lens for the refractive option is derived. We also present the simulation result of a sub-wavelength AR structure on both surfaces of silicon, which shows a band-averaged reflection of 1.1-3.2% at 101-448 GHz.

  19. Highly sensitive distributed birefringence measurements based on a two-pulse interrogation of a dynamic Brillouin grating

    NASA Astrophysics Data System (ADS)

    Soto, Marcelo A.; Denisov, Andrey; Angulo-Vinuesa, Xabier; Martin-Lopez, Sonia; Thévenaz, Luc; Gonzalez-Herraez, Miguel

    2017-04-01

    A method for distributed birefringence measurements is proposed based on the interference pattern generated by the interrogation of a dynamic Brillouin grating (DBG) using two short consecutive optical pulses. Compared to existing DBG interrogation techniques, the method here offers an improved sensitivity to birefringence changes thanks to the interferometric effect generated by the reflections of the two pulses. Experimental results demonstrate the possibility to obtain the longitudinal birefringence profile of a 20 m-long Panda fibre with an accuracy of 10-8 using 16 averages and 30 cm spatial resolution. The method enables sub-metric and highly-accurate distributed temperature and strain sensing.

  20. Accumulation of Mn(II) in Deinococcus radiodurans Facilitates Gamma-Radiation Resistance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, Michael J.; Gaidamakova, E; Matrosova, V

    2004-11-05

    Deinococcus radiodurans is extremely resistant to ionizing radiation. How this bacterium can grow under chronic gamma-radiation (50 Gy/hour) or recover from acute doses greater than 10 kGy is unknown. We show that D. radiodurans accumulates very high intracellular manganese and low iron levels compared to radiation sensitive bacteria, and resistance exhibits a concentration-dependent response to Mn(II). Among the most radiation-resistant bacterial groups reported, Deinococcus, Enterococcus, Lactobacillus and cyanobacteria spp. accumulate Mn(II). In contrast, Shewanella oneidensis and Pseudomonas putida have high Fe but low intracellular Mn concentrations and are very sensitive. We propose that Mn(II) accumulation facilitates recovery from radiation injury.

  1. Enhancement of high-resolution photoacoustic imaging with indocyanine green-conjugated carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Phuc Nguyen, Van; Oh, Yunok; Ha, Kanglyeol; Oh, Junghwan; Kang, Hyun Wook

    2015-07-01

    The current study indicates the feasibility of photoacoustic imaging (PAI) enhanced with contrast agents. A single-element ultrasound transducer (20 MHz) was used to detect PA signals for image reconstruction. To improve PA sensitivity, single-walled carbon nanotubes (SWNTs) conjugated with indocyanine green (ICG) were injected into samples at various concentrations. PA signal amplitudes linearly increased with SWNT-ICG concentration owing to strong light absorption. Compared with SWNTs, SWNT-ICG augmented the signal intensity by approximately 2-fold (concentration: 300 nM). The enhanced optical absorption can allow the application of SWNT-ICG to enable PAI for specifically identifying tumors with high sensitivity.

  2. CT should replace three-view radiographs as the initial screening test in patients at high, moderate, and low risk for blunt cervical spine injury: a prospective comparison.

    PubMed

    Bailitz, John; Starr, Frederic; Beecroft, Matthew; Bankoff, Jon; Roberts, Roxanne; Bokhari, Faran; Joseph, Kimberly; Wiley, Dorian; Dennis, Andrew; Gilkey, Susan; Erickson, Paul; Raksin, Patricia; Nagy, Kimberly

    2009-06-01

    An estimated 10,000 Americans suffer cervical spine injuries each year. More than 800,000 cervical spine radiographs (CSR) are ordered annually. The human and healthcare costs associated with these injuries are enormous especially when diagnosis is delayed. Controversy exists in the literature concerning the diagnostic accuracy of CSR, with reported sensitivity ranging from 32% to 89%. We sought to compare prospectively the sensitivity of cervical CT (CCT) to CSR in the initial diagnosis of blunt cervical spine injury for patients meeting one or more of the NEXUS criteria. The study prospectively compared the diagnostic accuracy of CSR to CCT in consecutive patients evaluated for blunt trauma during 23 months at an urban, public teaching hospital and Level I Trauma Center. Inclusion criteria were adult patient, evaluated for blunt cervical spine injury, meeting one or more of the NEXUS criteria. All patients received both three-view CSR and CCT as part of a standard diagnostic protocol. Each CSR and CCT study was interpreted independently by a different radiology attending who was blinded to the results of the other study. Clinically significant injuries were defined as those requiring one or more of the following interventions: operative procedure, halo application, and/or rigid cervical collar. Of 1,583 consecutive patients evaluated for blunt cervical spine trauma, 78 (4.9%) patients received only CCT or CSR and were excluded from the study. Of the remaining 1,505 patients, 78 (4.9%) had evidence of a radiographic injury by CSR or CCT. Of these 78 patients with radiographic injury, 50 (3.3%) patients had clinically significant injuries. CCT detected all patients with clinically significant injuries (100% sensitive), whereas CSR detected only 18 (36% sensitive). Of the 50 patients, 15 were at high risk, 19 at moderate risk, and 16 at low risk for cervical spine injury according to previously published risk stratification. CSR detected clinically significant injury in 7 high risk (46% sensitive), 7 moderate risk (37% sensitive), and 4 low risk patients (25% sensitive). Our results demonstrate the superiority of CCT compared with CSR for the detection of clinically significant cervical spine injury. The improved ability to exclude injury rapidly provides further evidence that CCT should replace CSR for the initial evaluation of blunt cervical spine injury in patients at any risk for injury.

  3. Advances on Sensitive Electron-injection based Cameras for Low-Flux, Short-Wave-Infrared Applications

    NASA Astrophysics Data System (ADS)

    Fathipour, Vala; Bonakdar, Alireza; Mohseni, Hooman

    2016-08-01

    Short-wave infrared (SWIR) photon detection has become an essential technology in the modern world. Sensitive SWIR detector arrays with high pixel density, low noise levels and high signal-to-noise-ratios are highly desirable for a variety of applications including biophotonics, light detection and ranging, optical tomography, and astronomical imaging. As such many efforts in infrared detector research are directed towards improving the performance of the photon detectors operating in this wavelength range. We review the history, principle of operation, present status and possible future developments of a sensitive SWIR detector technology, which has demonstrated to be one of the most promising paths to high pixel density focal plane arrays for low flux applications. The so-called electron-injection (EI) detector was demonstrated for the first time (in 2007). It offers an overall system-level sensitivity enhancement compared to the p-i-n diode due to a stable internal avalanche-free gain. The amplification method is inherently low noise, and devices exhibit an excess noise of unity. The detector operates in linear-mode and requires only bias voltage of a few volts. The stable detector characteristics, makes formation of high yield large-format, and high pixel density focal plane arrays less challenging compared to other detector technologies such as avalanche photodetectors. Detector is based on the mature InP material system (InP/InAlAs/GaAsSb/InGaAs), and has a cutoff wavelength of 1700 nm. It takes advantage of a unique three-dimensional geometry and combines the efficiency of a large absorbing volume with the sensitivity of a low-dimensional switch (injector) to sense and amplify signals. Current devices provide high-speed response ~ 5 ns rise time, and low jitter ~ 12 ps at room temperature. The internal dark current density is ~ 1 μA/cm2 at room temperature decreasing to 0.1 nA/cm2 at 160 K. EI detectors have been designed, fabricated, and tested during two generations of development and optimization cycles. We review our imager results using the first-generation detectors. In the second-generation devices, the dark current is reduced by two orders of magnitude, and bandwidth is improved by 4 orders of magnitude. The dark current density of the EI detector is shown to outperform the state-of-the-art technology, the

  4. A comparison of the imaging characteristics of the new Kodak Hyper Speed G film with the current T-MAT G/RA film and the CR 9000 system.

    PubMed

    Monnin, P; Gutierrez, D; Bulling, S; Lepori, D; Verdun, F R

    2005-10-07

    Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

  5. Analytical validation of a next generation sequencing liquid biopsy assay for high sensitivity broad molecular profiling.

    PubMed

    Plagnol, Vincent; Woodhouse, Samuel; Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg; Forshew, Tim

    2018-01-01

    Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications.

  6. Analytical validation of a next generation sequencing liquid biopsy assay for high sensitivity broad molecular profiling

    PubMed Central

    Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg

    2018-01-01

    Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications. PMID:29543828

  7. Evaluation of the BinaxNOW® Streptococcus pneumoniae antigen test on fresh, frozen and concentrated urine samples in elderly patients with and without community-acquired pneumonia.

    PubMed

    Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A

    2016-02-01

    We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Histopathological examination of nail clippings using PAS staining (HPE-PAS): gold standard in diagnosis of Onychomycosis.

    PubMed

    Jeelani, Shazia; Ahmed, Qazi Masood; Lanker, Audil Mohmad; Hassan, Iffat; Jeelani, Nasir; Fazili, Tawheeda

    2015-01-01

    Onychomycosis is fungal infection of one or more of the nail units. However, because fungi cause only about half of all nail dystrophies, the use of appropriate diagnostic techniques is important to ensure correct diagnosis and treatment. Aim of the present study was to compare direct microscopy, culture and HPE-PAS for diagnosis of onychomycosis by evaluating their sensitivity and various other relevant statistical parameters. A prospective, hospital-based, cross-sectional study was conducted on 216 patients with a high degree of clinical suspicion of onychomycosis. Nail specimens were evaluated using three diagnostic methods, i.e. direct microscopy using 20% Potassium hydroxide (KOH) & 40% Di-methyl-suphoxide (DMSO), culture and histopathological examination using PAS stain (HPE-PAS). Of 216 patients direct microscopy was positive in 138 (63.9%), culture in 147 (68%) and HPE-PAS in 164 patients (76%). One hundred and seventy-nine patients fitted into the criteria set for confirmed diagnosis of onychomycosis. Using this as a denominator; direct microscopy, culture and HPE-PAS had sensitivities of 77.1%, 70% and 91.6% respectively. Also, HPE-PAS showed the highest sensitivity of 94.7% in 19 cases with prediagnostic antimycotic treatment compared to direct microscopy (42.1%) or culture (57.9%). HPE-PAS shows high sensitivity for diagnosis of onychomycosis and can be considered as a gold standard in the diagnosis of onychomycosis. © 2014 Blackwell Verlag GmbH.

  9. Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards.

    PubMed

    Sato, K; Shidahara, M; Watabe, H; Watanuki, S; Ishikawa, Y; Arakawa, Y; Nai, Y H; Furumoto, S; Tashiro, M; Shoji, T; Yanai, K; Gonda, K

    2016-01-21

    The aim of this study was to evaluate the performance of ClairvivoPET using NEMA NU4 standards. The ClairvivoPET incorporates a LYSO dual depth-of-interaction detector system with 151 mm axial field of view (FOV). Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated using NEMA NU4-2008 standards. Normal mouse imaging was also performed for 10 min after intravenous injection of (18)F(-)-NaF. Data were compared with 19 other preclinical PET scanners. Spatial resolution measured using full width at half maximum on FBP-ramp reconstructed images was 2.16 mm at radial offset 5 mm of the axial centre FOV. The maximum absolute sensitivity for a point source at the FOV centre was 8.72%. Peak noise equivalent counting rate (NECR) was 415 kcps at 14.6 MBq ml(-1). The uniformity with the image-quality phantom was 4.62%. Spillover ratios in the images of air and water filled chambers were 0.19 and 0.06, respectively. Our results were comparable with the 19 other preclinical PET scanners based on NEMA NU4 standards, with excellent sensitivity because of the large FOV. The ClairvivoPET with iterative reconstruction algorithm also provided sufficient visualization of the mouse spine. The high sensitivity and resolution of the ClairvivoPET scanner provided high quality images for preclinical studies.

  10. Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards

    NASA Astrophysics Data System (ADS)

    Sato, K.; Shidahara, M.; Watabe, H.; Watanuki, S.; Ishikawa, Y.; Arakawa, Y.; Nai, YH; Furumoto, S.; Tashiro, M.; Shoji, T.; Yanai, K.; Gonda, K.

    2016-01-01

    The aim of this study was to evaluate the performance of ClairvivoPET using NEMA NU4 standards. The ClairvivoPET incorporates a LYSO dual depth-of-interaction detector system with 151 mm axial field of view (FOV). Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated using NEMA NU4-2008 standards. Normal mouse imaging was also performed for 10min after intravenous injection of 18F(-)-NaF. Data were compared with 19 other preclinical PET scanners. Spatial resolution measured using full width at half maximum on FBP-ramp reconstructed images was 2.16 mm at radial offset 5 mm of the axial centre FOV. The maximum absolute sensitivity for a point source at the FOV centre was 8.72%. Peak noise equivalent counting rate (NECR) was 415kcps at 14.6MBq ml-1. The uniformity with the image-quality phantom was 4.62%. Spillover ratios in the images of air and water filled chambers were 0.19 and 0.06, respectively. Our results were comparable with the 19 other preclinical PET scanners based on NEMA NU4 standards, with excellent sensitivity because of the large FOV. The ClairvivoPET with iterative reconstruction algorithm also provided sufficient visualization of the mouse spine. The high sensitivity and resolution of the ClairvivoPET scanner provided high quality images for preclinical studies.

  11. Different gain/loss sensitivity and social adaptation ability in gifted adolescents during a public goods game.

    PubMed

    Chung, Dongil; Yun, Kyongsik; Kim, Jin Ho; Jang, Bosun; Jeong, Jaeseung

    2011-02-16

    Gifted adolescents are considered to have high IQs with advanced mathematical and logical performances, but are often thought to suffer from social isolation or emotional mal-adaptation to the social group. The underlying mechanisms that cause stereotypic portrayals of gifted adolescents are not well known. We aimed to investigate behavioral performance of gifted adolescents during social decision-making tasks to assess their affective and social/non-social cognitive abilities. We examined cooperation behaviors of 22 gifted and 26 average adolescents during an iterative binary public goods (PG) game, a multi-player social interaction game, and analyzed strategic decision processes that include cooperation and free-riding. We found that the gifted adolescents were more cooperative than average adolescents. Particularly, comparing the strategies for the PG game between the two groups, gifted adolescents were less sensitive to loss, yet were more sensitive to gain. Additionally, the behavioral characteristics of average adolescents, such as low trust of the group and herding behavior, were not found in gifted adolescents. These results imply that gifted adolescents have a high cognitive ability but a low ability to process affective information or to adapt in social groups compared with average adolescents. We conclude that gain/loss sensitivity and the ability to adapt in social groups develop to different degrees in average and gifted adolescents.

  12. Limited predictive ability of surrogate indices of insulin sensitivity/resistance in Asian-Indian men.

    PubMed

    Muniyappa, Ranganath; Irving, Brian A; Unni, Uma S; Briggs, William M; Nair, K Sreekumaran; Quon, Michael J; Kurpad, Anura V

    2010-12-01

    Insulin resistance is highly prevalent in Asian Indians and contributes to worldwide public health problems, including diabetes and related disorders. Surrogate measurements of insulin sensitivity/resistance are used frequently to study Asian Indians, but these are not formally validated in this population. In this study, we compared the ability of simple surrogate indices to accurately predict insulin sensitivity as determined by the reference glucose clamp method. In this cross-sectional study of Asian-Indian men (n = 70), we used a calibration model to assess the ability of simple surrogate indices for insulin sensitivity [quantitative insulin sensitivity check index (QUICKI), homeostasis model assessment (HOMA2-IR), fasting insulin-to-glucose ratio (FIGR), and fasting insulin (FI)] to predict an insulin sensitivity index derived from the reference glucose clamp method (SI(Clamp)). Predictive accuracy was assessed by both root mean squared error (RMSE) of prediction as well as leave-one-out cross-validation-type RMSE of prediction (CVPE). QUICKI, FIGR, and FI, but not HOMA2-IR, had modest linear correlations with SI(Clamp) (QUICKI: r = 0.36; FIGR: r = -0.36; FI: r = -0.27; P < 0.05). No significant differences were noted among CVPE or RMSE from any of the surrogate indices when compared with QUICKI. Surrogate measurements of insulin sensitivity/resistance such as QUICKI, FIGR, and FI are easily obtainable in large clinical studies, but these may only be useful as secondary outcome measurements in assessing insulin sensitivity/resistance in clinical studies of Asian Indians.

  13. Sensitivity to Secondhand Smoke Exposure Predicts Smoking Susceptibility in 8 to 13 Year-Old Never Smokers

    PubMed Central

    Lessov-Schlaggar, Christina N.; Wahlgren, Dennis R.; Liles, Sandy; Jones, Jennifer A.; Ji, Ming; Hughes, Suzanne C.; Swan, Gary E.; Hovell, Melbourne F.

    2010-01-01

    Purpose To investigate the sensitivity to secondhand smoke exposure (SHSe) in preteens age 8 to 13 who have never smoked, and to determine whether SHSe sensitivity predicts smoking susceptibility. Methods We assessed sensitivity to SHSe using reactions commonly used for assessment of sensitivity to the first smoked cigarette (e.g., feeling dizzy), and investigated the factor structure of these reactions for the purpose of data reduction. We examined the association of each reaction measure and summary score with demographic characteristics and with smoking susceptibility, using logistic regression and ordinal logistic regression. Results One factor was identified that captured physical/unpleasant reactions. Older preteens and preteens with more highly educated parents reported fewer reactions to SHSe. More African American preteens reported feeling relaxed or calm compared to all other racial/ethnic groups. Experiencing physical/unpleasant reactions to SHSe predicted lower risk for smoking susceptibility. Conclusions This was the first study to extend analytical methodology for sensitivity to active smoking to sensitivity to SHSe in youth who have never smoked. Results suggest a desensitization process with age and lower sensitivity to some reactions in preteens from more highly educated households. Preteens who have more aversive experience s with SHSe tend to be less susceptible to smoking than those who experience fewer aversive reactions. Assessment of sensitivity to SHSe is a novel approach to the study of cigarette use etiology and may contribute to better prediction of smoking initiation. PMID:21338893

  14. Infant temperamental reactivity, maternal and grandparental sensitivity: Differential susceptibility for behavior problems in China.

    PubMed

    Xing, Shufen; Zhou, Quan; Archer, Marc; Yue, Jianhong; Wang, Zhengyan

    2016-10-01

    The differential susceptibility hypothesis suggests that children's innate characteristics and their rearing experiences interact differentially during development. Recently, the study of interactions between infants' temperament and rearing experiences has become a research hotspot. In China, grandparental care is a very common phenomenon, with many infants taken care of by grandparents while mothers are out for work. To investigate whether the associations between maternal and grandmaternal sensitivity, and behavior problems were moderated by infant temperamental reactivity, while the infants were raised by both their mothers and grandmothers. A total of 71 infants (average age of 17.6months), their mothers and grandmothers were included in this study. Maternal sensitivity and grandmaternal sensitivity were assessed with the Maternal Behavior Q-sort-Chinese Version, infants' temperamental reactivity was measured with Carey's Toddler Temperament Questionnaire-Chinese Revision, and infants' behavior problems were measured with the Infant-Toddler Social and Emotional Assessment-Chinese Version. Maternal sensitivity significantly predicted infants' impulsivity and aggression. Infants' temperamental reactivity moderated the effect of maternal sensitivity on infants' general anxiety. In addition, infant temperamental reactivity moderated the impact of grandmaternal sensitivity on infants' separation distress. Our results support the differential susceptibility hypothesis to some extent. Infants with high temperamental reactivity not only suffer more from low maternal and grandmaternal sensitivity, but also benefit more from high maternal and grandmaternal sensitivity as compared to those infants with low temperamental reactivity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Evaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.

    PubMed

    Hiwatashi, A; Yoshiura, T; Togao, O; Yamashita, K; Kikuchi, K; Kobayashi, K; Ohga, M; Sonoda, S; Honda, H; Obara, M

    2014-01-01

    3D turbo field echo with diffusion-sensitized driven-equilibrium preparation is a non-echo-planar technique for DWI, which enables high-resolution DWI without field inhomogeneity-related image distortion. The purpose of this study was to evaluate the feasibility of diffusion-sensitized driven-equilibrium turbo field echo in evaluating diffusivity in the normal pituitary gland. First, validation of diffusion-sensitized driven-equilibrium turbo field echo was attempted by comparing it with echo-planar DWI. Five healthy volunteers were imaged by using diffusion-sensitized driven-equilibrium turbo field echo and echo-planar DWI. The imaging voxel size was 1.5 × 1.5 × 1.5 mm(3) for diffusion-sensitized driven-equilibrium turbo field echo and 1.5 × 1.9 × 3.0 mm(3) for echo-planar DWI. ADCs measured by the 2 methods in 15 regions of interests (6 in gray matter and 9 in white matter) were compared by using the Pearson correlation coefficient. The ADC in the pituitary anterior lobe was then measured in 10 volunteers by using diffusion-sensitized driven-equilibrium turbo field echo, and the results were compared with those in the pons and vermis by using a paired t test. The ADCs from the 2 methods showed a strong correlation (r = 0.79; P < .0001), confirming the accuracy of the ADC measurement with the diffusion-sensitized driven-equilibrium sequence. The ADCs in the normal pituitary gland were 1.37 ± 0.13 × 10(-3) mm(2)/s, which were significantly higher than those in the pons (1.01 ± 0.24 × 10(-3) mm(2)/s) and the vermis (0.89 ± 0.25 × 10(-3) mm(2)/s, P < .01). We demonstrated that diffusion-sensitized driven-equilibrium turbo field echo is feasible in assessing ADC in the pituitary gland.

  16. Omega-3 fatty acid therapy dose-dependently and significantly decreased triglycerides and improved flow-mediated dilation, however, did not significantly improve insulin sensitivity in patients with hypertriglyceridemia.

    PubMed

    Oh, Pyung Chun; Koh, Kwang Kon; Sakuma, Ichiro; Lim, Soo; Lee, Yonghee; Lee, Seungik; Lee, Kyounghoon; Han, Seung Hwan; Shin, Eak Kyun

    2014-10-20

    Experimental studies demonstrate that higher intake of omega-3 fatty acids (n-3 FA) improves insulin sensitivity, however, we reported that n-3 FA 2g therapy, most commonly used dosage did not significantly improve insulin sensitivity despite reducing triglycerides by 21% in patients. Therefore, we investigated the effects of different dosages of n-3 FA in patients with hypertriglyceridemia. This was a randomized, single-blind, placebo-controlled, parallel study. Age, sex, and body mass index were matched among groups. All patients were recommended to maintain a low fat diet. Forty-four patients (about 18 had metabolic syndrome/type 2 diabetes mellitus) in each group were given placebo, n-3 FA 1 (O1), 2 (O2), or 4 g (O4), respectively daily for 2 months. n-3 FA therapy dose-dependently and significantly decreased triglycerides and triglycerides/HDL cholesterol and improved flow-mediated dilation, compared with placebo (by ANOVA). However, each n-3 FA therapy did not significantly decrease high-sensitivity C-reactive protein and fibrinogen, compared with placebo. O1 significantly increased insulin levels and decreased insulin sensitivity (determined by QUICKI) and O2 significantly decreased plasma adiponectin levels relative to baseline measurements. Of note, when compared with placebo, each n-3 FA therapy did not significantly change insulin, glucose, adiponectin, glycated hemoglobin levels and insulin sensitivity (by ANOVA). We observed similar results in a subgroup of patients with the metabolic syndrome. n-3 FA therapy dose-dependently and significantly decreased triglycerides and improved flow-mediated dilation. Nonetheless, n-3 FA therapy did not significantly improve acute-phase reactants and insulin sensitivity in patients with hypertriglyceridemia, regardless of dosages. Copyright © 2014. Published by Elsevier Ireland Ltd.

  17. Theoretical study of surface plasmon resonance sensors based on 2D bimetallic alloy grating

    NASA Astrophysics Data System (ADS)

    Dhibi, Abdelhak; Khemiri, Mehdi; Oumezzine, Mohamed

    2016-11-01

    A surface plasmon resonance (SPR) sensor based on 2D alloy grating with a high performance is proposed. The grating consists of homogeneous alloys of formula MxAg1-x, where M is gold, copper, platinum and palladium. Compared to the SPR sensors based a pure metal, the sensor based on angular interrogation with silver exhibits a sharper (i.e. larger depth-to-width ratio) reflectivity dip, which provides a big detection accuracy, whereas the sensor based on gold exhibits the broadest dips and the highest sensitivity. The detection accuracy of SPR sensor based a metal alloy is enhanced by the increase of silver composition. In addition, the composition of silver which is around 0.8 improves the sensitivity and the quality of SPR sensor of pure metal. Numerical simulations based on rigorous coupled wave analysis (RCWA) show that the sensor based on a metal alloy not only has a high sensitivity and a high detection accuracy, but also exhibits a good linearity and a good quality.

  18. Parasites under the Spotlight: Applications of Vibrational Spectroscopy to Malaria Research.

    PubMed

    Perez-Guaita, David; Marzec, Katarzyna M; Hudson, Andrew; Evans, Corey; Chernenko, Tatyana; Matthäus, Christian; Miljkovic, Milos; Diem, Max; Heraud, Philip; Richards, Jack S; Andrew, Dean; Anderson, David A; Doerig, Christian; Garcia-Bustos, Jose; McNaughton, Don; Wood, Bayden R

    2018-04-20

    New technologies to diagnose malaria at high sensitivity and specificity are urgently needed in the developing world where the disease continues to pose a huge burden on society. Infrared and Raman spectroscopy-based diagnostic methods have a number of advantages compared with other diagnostic tests currently on the market. These include high sensitivity and specificity for detecting low levels of parasitemia along with ease of use and portability. Here, we review the application of vibrational spectroscopic techniques for monitoring and detecting malaria infection. We discuss the role of vibrational (infrared and Raman) spectroscopy in understanding the processes of parasite biology and its application to the study of interactions with antimalarial drugs. The distinct molecular phenotype that characterizes malaria infection and the high sensitivity enabling detection of low parasite densities provides a genuine opportunity for vibrational spectroscopy to become a front-line tool in the elimination of this deadly disease and provide molecular insights into the chemistry of this unique organism.

  19. Now or not-now? The influence of alexithymia on intertemporal decision-making.

    PubMed

    Scarpazza, Cristina; Sellitto, Manuela; di Pellegrino, Giuseppe

    2017-06-01

    Optimal intertemporal decisions arise from the balance between an emotional-visceral component, signaling the need for immediate gratification, and a rational, long-term oriented component. Alexithymia, a personality construct characterized by amplified sensitivity to internal bodily signals of arousal, may result in enhanced activation of the emotional-visceral component over the cognitive-rational one. To test this hypothesis, participants with high- and low-alexithymia level were compared at an intertemporal decision-making task, and their choice behavior correlated with their interoceptive sensitivity. We show that high-alexithymic tend to behave more impatiently than low-alexithymic in intertemporal decisions, particularly when the sooner reward is immediately available. Moreover, the greater their sensitivity to their own visceral sensations, the greater the impatience. Together, these results suggest a disproportionate valuation of reward available immediately in high alexithymia, possibly reflecting heightened perception of bodily physiological signals, which ultimately would bias their intertemporal decision-making. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Automated High-Speed Video Detection of Small-Scale Explosives Testing

    NASA Astrophysics Data System (ADS)

    Ford, Robert; Guymon, Clint

    2013-06-01

    Small-scale explosives sensitivity test data is used to evaluate hazards of processing, handling, transportation, and storage of energetic materials. Accurate test data is critical to implementation of engineering and administrative controls for personnel safety and asset protection. Operator mischaracterization of reactions during testing contributes to either excessive or inadequate safety protocols. Use of equipment and associated algorithms to aid the operator in reaction determination can significantly reduce operator error. Safety Management Services, Inc. has developed an algorithm to evaluate high-speed video images of sparks from an ESD (Electrostatic Discharge) machine to automatically determine whether or not a reaction has taken place. The algorithm with the high-speed camera is termed GoDetect (patent pending). An operator assisted version for friction and impact testing has also been developed where software is used to quickly process and store video of sensitivity testing. We have used this method for sensitivity testing with multiple pieces of equipment. We present the fundamentals of GoDetect and compare it to other methods used for reaction detection.

  1. Piezoresistive effect observed in flexible amorphous carbon films

    NASA Astrophysics Data System (ADS)

    Wang, B.; Jiang, Y. C.; Zhao, R.; Liu, G. Z.; He, A. P.; Gao, J.

    2018-05-01

    Amorphous carbon (a-C) films, deposited on Si substrates at 500 °C, were transferred onto flexible polyethylene (PE) substrates by a lift-off method, which overcomes the limit of deposition temperature. After transferring, a-C films exhibited a large piezoresistive effect. Such flexible samples could detect the change of bending angle by attaching them onto Cu foils. The ratio of the bending and non-bending resistances reaches as large as ~27.8, which indicates a potential application as a pressure sensor. Also, the a-C/PE sample revealed an enhanced sensitivity to gas pressure compared with the a-C/Si one. By controlling the bending angle, the sensitivity range can be tuned to shift to a low- or high-pressure region. The fatigue test shows a less than 1% change in resistance after 10 000 bending cycles. Our work provides a route to prepare the flexible and piezoresistive carbon-based devices with high sensitivity, controllable pressure-sensing and high stability.

  2. Creating a Computer Adaptive Test Version of the Late-Life Function & Disability Instrument

    PubMed Central

    Jette, Alan M.; Haley, Stephen M.; Ni, Pengsheng; Olarsch, Sippy; Moed, Richard

    2009-01-01

    Background This study applied Item Response Theory (IRT) and Computer Adaptive Test (CAT) methodologies to develop a prototype function and disability assessment instrument for use in aging research. Herein, we report on the development of the CAT version of the Late-Life Function & Disability instrument (Late-Life FDI) and evaluate its psychometric properties. Methods We employed confirmatory factor analysis, IRT methods, validation, and computer simulation analyses of data collected from 671 older adults residing in residential care facilities. We compared accuracy, precision, and sensitivity to change of scores from CAT versions of two Late-Life FDI scales with scores from the fixed-form instrument. Score estimates from the prototype CAT versus the original instrument were compared in a sample of 40 older adults. Results Distinct function and disability domains were identified within the Late-Life FDI item bank and used to construct two prototype CAT scales. Using retrospective data, scores from computer simulations of the prototype CAT scales were highly correlated with scores from the original instrument. The results of computer simulation, accuracy, precision, and sensitivity to change of the CATs closely approximated those of the fixed-form scales, especially for the 10- or 15-item CAT versions. In the prospective study each CAT was administered in less than 3 minutes and CAT scores were highly correlated with scores generated from the original instrument. Conclusions CAT scores of the Late-Life FDI were highly comparable to those obtained from the full-length instrument with a small loss in accuracy, precision, and sensitivity to change. PMID:19038841

  3. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  4. Dose response of exercise training following roux-en-Y gastric bypass surgery: A randomized trial.

    PubMed

    Woodlief, Tracey L; Carnero, Elvis A; Standley, Robert A; Distefano, Giovanna; Anthony, Steve J; Dubis, Gabe S; Jakicic, John M; Houmard, Joseph A; Coen, Paul M; Goodpaster, Bret H

    2015-12-01

    Roux-en-Y gastric bypass (RYGB) surgery can cause profound weight loss and improve overall cardiometabolic risk factors. Exercise (EX) training following RYGB can provide additional improvements in insulin sensitivity (SI ) and cardiorespiratory fitness. However, it remains unknown whether a specific amount of EX post-RYGB is required to achieve additional benefits. We performed a post hoc analysis of participants who were randomized into either a 6-month structured EX program or a health education control (CON). The EX group (n = 56) was divided into tertiles according to the amount of weekly exercise performed, compared with CON (n = 42): low-EX = 54 ± 8; middle-EX = 129 ± 4; and high-EX = 286 ± 40 min per week. The high-EX lost a significantly greater amount of body weight, total fat mass, and abdominal deep subcutaneous abdominal fat compared with CON (P < 0.005). SI improved to a greater extent in both the middle-EX and high-EX compared with CON (P < 0.04). Physical fitness (VO2 max) significantly improved in the high-EX (9.3% ± 4.2%) compared with CON (-6.0 ± 2.4%) (P < 0.001). Skeletal muscle mitochondrial State 4 (P < 0.002) and 3 (P < 0.04) respiration was significantly higher in the high-EX compared with CON. A modest volume of structured exercise provides additional improvements in insulin sensitivity following RYGB, but higher volumes of exercise are required to induce additional weight loss, changes in body composition, and improvements in cardiorespiratory fitness and skeletal muscle mitochondrial capacity. © 2015 The Obesity Society.

  5. Comparison of vildagliptin and glimepiride: effects on glycaemic control, fat tolerance and inflammatory markers in people with type 2 diabetes.

    PubMed

    Derosa, G; Bonaventura, A; Bianchi, L; Romano, D; Fogari, E; D'Angelo, A; Maffioli, P

    2014-12-01

    To compare the effects of vildagliptin with those of glimepiride on glycaemic control, fat tolerance and inflammatory markers in people with Type 2 diabetes mellitus receiving metformin treatment. A total of 167 participants were randomized to vildagliptin 50 mg twice a day or glimepiride 2 mg three times a day, for 6 months. We evaluated the following variables: BMI; glycaemic control; fasting plasma insulin; homeostatic model assessment of insulin resistance index; fasting plasma proinsulin; glucagon; lipid profile; adiponectin; high-sensitivity C-reactive protein; interleukin-6; and tumour necrosis factor-α. A euglycaemic-hyperinsulinaemic clamp procedure and an oral fat load test were also performed. Despite a similar decrease in HbA1c levels (P = 0.009, and P = 0.008, respectively), body weight increased with glimepiride (P = 0.048 vs baseline) and decreased with vildagliptin (P = 0.041 vs baseline and vs glimepiride). Fasting plasma insulin and homeostatic model assessment of insulin resistance index were significantly lower with vildagliptin compared with glimepiride (P = 0.035 and 0.047). M value, an index of insulin sensitivity, increased with vildagliptin, both compared with baseline and with glimepiride (P = 0.028 and 0.039, respectively). Vildagliptin improved all post-oral fat load peaks of lipid profile compared with glimepiride. Adiponectin levels were higher (P = 0.035) and high-sensitivity C-reactive protein levels were lower (P = 0.038) with vildagliptin vs glimepiride. During the oral fat load test, interleukin-6, high-sensitivity C-reactive protein and tumour necrosis factor-α peaks were lower and adiponectin peak was higher in the vildagliptin group than in the glimepiride group. There was a higher dropout rate as a result of hypoglycaemia in the glimepiride group than in the vildagliptin group. Vildagliptin was more effective than glimepiride in reducing post-oral fat load peaks of lipid-trafficking adipocytokines and inflammatory markers. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  6. Effect of Temperature and Dynamic Loading on the Mechanical Properties of Copper-Alloyed High-Strength Interstitial-Free Steel

    NASA Astrophysics Data System (ADS)

    Rana, R.; Singh, S. B.; Bleck, W.; Mohanty, O. N.

    2009-04-01

    Crash resistance and formability relevant mechanical properties of a copper-alloyed interstitial-free (IF) steel processed under various conditions of batch annealing (BA), continuous annealing (CA), and postcontinuous annealing aging have been studied in a wide range of strain rate (3.33 × 10-4 to 200 s-1) and temperature (-100 °C to +20 °C). These properties have been compared with similarly processed traditional mild and high-strength IF steels. Assessment of various parameters such as strength, elongation, strain rate sensitivity of stress, strain-hardening capacity, temperature sensitivity of stress, activation volume, and specific energy absorption of all these steels implies that copper-alloyed IF steel is soft and formable in CA condition. It can be made stronger and more crash resistant than the conventional mild- or high-strength IF steels when aged to peak strength after CA. Room-temperature strain rate sensitivity of stress of the investigated steels exhibits a two-stage behavior. Copper in solution in ferrite causes solid solution softening at low temperatures (≤20 °C) and at high strain rates (200 s-1).

  7. Supramolecular fabrication of multilevel graphene-based gas sensors with high NO2 sensibility.

    PubMed

    Chen, Zhuo; Umar, Ahmad; Wang, Shiwei; Wang, Yao; Tian, Tong; Shang, Ying; Fan, Yuzun; Qi, Qi; Xu, Dongmei; Jiang, Lei

    2015-06-14

    This study reports the supramolecular assembly of a silver nanoparticle-naphthalene-1-sulphonic acid-reduced graphene oxide composite (Ag-NA-rGO) and its utilization to fabricate a highly sensitive and selective gas sensor. The prepared supramolecular assembly acted not only as a non-covalent functionalization platform (π-π interaction) but was also an excellent scaffold to fabricate a highly sensitive and selective low concentration NO2 gas sensor. The prepared composites were characterized using several techniques, which revealed that the graphene sheets were dispersed as ultrathin monolayers with a uniform distribution of silver nanoparticles. The fabricated multilevel structure exhibited an excellent sensing performance, i.e. 2.8 times better, towards 10 ppm NO2 compared to the NA-rGO and rGO based sensors. Apart from its high sensitivity, superior reversibility and selectivity, the prepared supramolecular assembly exhibited an outstanding linear response over the large concentration range from 1 ppm to 10 ppm. The obtained results demonstrate that the prepared supramolecular assembly holds great potential in the fabrication of efficient and effective low-concentration NO2 gas sensors for practical applications.

  8. Magical ideation and hyperacusis.

    PubMed

    Dubal, Stéphanie; Viaud-Delmon, Isabelle

    2008-01-01

    The subjective experience conferred by auditory perception has rarely been addressed outside of the studies of auditory hallucinations. The aim of this study is to describe the phenomenology of auditory experiences in individuals who endorse magical beliefs, but do not report hallucinations. We examined the relationship between subjective auditory sensitivity and a 'psychotic-like' thinking style. Hyperacusis questionnaire scores were compared between 25 high scoring participants on Chapman's magical ideation (MI) scale, 25 high scoring participants on Chapman's physical anhedonia scale and 25 control participants, pre-selected from a large student pool (n=1289). The participants who obtained high scores on the MI scale rated their auditory sensitivity higher than the two other groups. Our results indicate that, in healthy subjects, subjective auditory sensitivity is associated with MI without the mediation by anxiety commonly observed in pathological cases. We propose that hyperacusis associated to high scores of MI may be a predispositional factor to deviant auditory experiences. The relative uncoupling of perception from auditory sensory input may result in a central hypersensitivity, which could play a role in triggering off the experience of auditory hallucinations.

  9. Coffee and caffeine improve insulin sensitivity and glucose tolerance in C57BL/6J mice fed a high-fat diet.

    PubMed

    Matsuda, Yuji; Kobayashi, Misato; Yamauchi, Rie; Ojika, Makoto; Hiramitsu, Masanori; Inoue, Takashi; Katagiri, Takao; Murai, Atsushi; Horio, Fumihiko

    2011-01-01

    We have previously demonstrated that coffee and caffeine ameliorated hyperglycemia in spontaneously diabetic KK-A(y) mice. This present study evaluates the antidiabetic effects of coffee and caffeine on high-fat-diet-induced impaired glucose tolerance in C57BL/6J mice. C57BL/6J mice fed a high-fat diet were given regular drinking water (control group), or a 2.5-fold-diluted coffee or caffeine solution (200 mg/L) for 17 weeks. The ingestion of coffee or caffeine improved glucose tolerance, insulin sensitivity, and hyperinsulinemia when compared with mice in the control group. The adipose tissue mRNA levels of inflammatory adipocytokines (MCP-1 and IL-6) and the liver mRNA levels of genes related to fatty acid synthesis were lower in the coffee and caffeine groups than those in the control group. These results suggest that coffee and caffeine exerted an ameliorative effect on high-fat-diet-induced impaired glucose tolerance by improving insulin sensitivity. This effect might be attributable in part to the reduction of inflammatory adipocytokine expression.

  10. Radiative lifetimes and transition probabilities for electric-dipole delta n equals zero transitions in highly stripped sulfur ions

    NASA Technical Reports Server (NTRS)

    Pegg, D. J.; Elston, S. B.; Griffin, P. M.; Forester, J. P.; Thoe, R. S.; Peterson, R. S.; Sellin, I. A.; Hayden, H. C.

    1976-01-01

    The beam-foil time-of-flight method has been used to investigate radiative lifetimes and transition rates involving allowed intrashell transitions within the L shell of highly ionized sulfur. The results for these transitions, which can be particularly correlation-sensitive, are compared with current calculations based upon multiconfigurational models.

  11. C-reactive protein, marker for evaluation of systemic inflammatory response in preeclampsia.

    PubMed

    Mihu, D; Costin, N; Mihu, Carmen Mihaela; Blaga, Ligia Daniela; Pop, Raluca Bogdana

    2008-01-01

    Determination by a high sensitivity technique of serum C-reactive protein (CRP), a sensitive marker of inflammation in women with preeclampsia compared to normal pregnancy and investigation of the relationship between CRP and the severity of the preeclamptic syndrome. The study included 40 women with preeclampsia and 40 control subjects with normal pregnancies in the last trimester of pregnancy. The serum CRP concentration was determined using the universal high sensitivity immunoturbidimetric assay. The serum CRP concentration was significantly higher (p < 0.001) in preclampsia (5.69 +/- 1.8 mg/L) compared to normal pregnancy (2.89 +/- 1.2 mg/L). In women with preeclampsia, CRP correlated positively and significantly with diastolic blood pressure, proteinuria and uric acid levels. Maternal CRP values also correlated negatively and significantly with fetal weight at birth. Our results demonstrate that serum CRP is increased in preeclampsia and represents a marker of the severity of the preeclamptic syndrome and of fetal weight at birth. Taking into consideration these observations and the fact that CRP testing is rapid and relatively inexpensive, we recommend the use of this acute phase reagent in clinical practice, in all women with preeclampsia in order to establish the prognosis of the disease.

  12. Dark-field optical coherence microscopy

    NASA Astrophysics Data System (ADS)

    Pache, C.; Villiger, M. L.; Lasser, T.

    2010-02-01

    Many solutions have been proposed to produce phase quantitative images of biological cell samples. Among these, Spectral Domain Phase Microscopy combines the fast imaging speed and high sensitivity of Optical Coherence Microscopy (OCM) in the Fourier domain with the high phase stability of common-path interferometry. We report on a new illumination scheme for OCM that enhances the sensitivity for backscattered light and detects the weak sample signal, otherwise buried by the signal from specular reflection. With the use of a Bessel-like beam, a dark-field configuration was realized. Sensitivity measurements for three different illumination configurations were performed to compare our method to standard OCM and extended focus OCM. Using a well-defined scattering and reflecting object, we demonstrated an attenuation of -40 dB of the DC-component and a relative gain of 30 dB for scattered light, compared to standard OCM. In a second step, we applied this technique, referred to as dark-field Optical Coherence Microscopy (dfOCM), to living cells. Chinese hamster ovarian cells were applied in a drop of medium on a coverslide. The cells of ~15 μm in diameter and even internal cell structures were visualized in the acquired tomograms.

  13. Comparison of Travel-Time and Amplitude Measurements for Deep-Focusing Time-Distance Helioseismology

    NASA Astrophysics Data System (ADS)

    Pourabdian, Majid; Fournier, Damien; Gizon, Laurent

    2018-04-01

    The purpose of deep-focusing time-distance helioseismology is to construct seismic measurements that have a high sensitivity to the physical conditions at a desired target point in the solar interior. With this technique, pairs of points on the solar surface are chosen such that acoustic ray paths intersect at this target (focus) point. Considering acoustic waves in a homogeneous medium, we compare travel-time and amplitude measurements extracted from the deep-focusing cross-covariance functions. Using a single-scattering approximation, we find that the spatial sensitivity of deep-focusing travel times to sound-speed perturbations is zero at the target location and maximum in a surrounding shell. This is unlike the deep-focusing amplitude measurements, which have maximum sensitivity at the target point. We compare the signal-to-noise ratio for travel-time and amplitude measurements for different types of sound-speed perturbations, under the assumption that noise is solely due to the random excitation of the waves. We find that, for highly localized perturbations in sound speed, the signal-to-noise ratio is higher for amplitude measurements than for travel-time measurements. We conclude that amplitude measurements are a useful complement to travel-time measurements in time-distance helioseismology.

  14. Flow cytometry shows added value in diagnosing lymphoma in brain biopsies.

    PubMed

    van der Meulen, Matthijs; Bromberg, Jacoline E C; Lam, King H; Dammers, Ruben; Langerak, Anton W; Doorduijn, Jeanette K; Kros, Johan M; van den Bent, Martin J; van der Velden, Vincent H J

    2018-05-10

    To assess the sensitivity, specificity and turnaround time of flow cytometric analysis on brain biopsies compared to histology plus immunohistochemistry analysis in tumors with clinical suspicion of lymphoma. All brain biopsies performed between 2010 and 2015 at our institution and analyzed by both immunohistochemistry and flow cytometry were included in this retrospective study. Immunohistochemistry was considered the gold standard. In a total of 77 biopsies from 71 patients, 49 lymphomas were diagnosed by immunohistochemistry, flow cytometry results were concordant in 71 biopsies (92,2%). We found a specificity and sensitivity of flow cytometry of 100% and 87,8%, respectively. The time between the biopsy and reporting the result (turnaround time) was significantly shorter for flow cytometry, compared to immunohistochemistry (median: 1 versus 5 days). Flow cytometry has a high specificity and can confirm the diagnosis of a lymphoma significantly faster than immunohistochemistry. This allows for rapid initiation of treatment in this highly aggressive tumor. However, since its sensitivity is less than 100%, we recommend to perform histology plus immunohistochemistry in parallel to flow cytometry. This article is protected by copyright. All rights reserved. © 2018 International Clinical Cytometry Society.

  15. CAFNA{reg{underscore}sign}, coded aperture fast neutron analysis for contraband detection: Preliminary results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, L.; Lanza, R.C.

    1999-12-01

    The authors have developed a near field coded aperture imaging system for use with fast neutron techniques as a tool for the detection of contraband and hidden explosives through nuclear elemental analysis. The technique relies on the prompt gamma rays produced by fast neutron interactions with the object being examined. The position of the nuclear elements is determined by the location of the gamma emitters. For existing fast neutron techniques, in Pulsed Fast Neutron Analysis (PFNA), neutrons are used with very low efficiency; in Fast Neutron Analysis (FNS), the sensitivity for detection of the signature gamma rays is very low.more » For the Coded Aperture Fast Neutron Analysis (CAFNA{reg{underscore}sign}) the authors have developed, the efficiency for both using the probing fast neutrons and detecting the prompt gamma rays is high. For a probed volume of n{sup 3} volume elements (voxels) in a cube of n resolution elements on a side, they can compare the sensitivity with other neutron probing techniques. As compared to PFNA, the improvement for neutron utilization is n{sup 2}, where the total number of voxels in the object being examined is n{sup 3}. Compared to FNA, the improvement for gamma-ray imaging is proportional to the total open area of the coded aperture plane; a typical value is n{sup 2}/2, where n{sup 2} is the number of total detector resolution elements or the number of pixels in an object layer. It should be noted that the actual signal to noise ratio of a system depends also on the nature and distribution of background events and this comparison may reduce somewhat the effective sensitivity of CAFNA. They have performed analysis, Monte Carlo simulations, and preliminary experiments using low and high energy gamma-ray sources. The results show that a high sensitivity 3-D contraband imaging and detection system can be realized by using CAFNA.« less

  16. Introduction of a hydrolysis probe PCR assay for high-throughput screening of methicillin-resistant Staphylococcus aureus with the ability to include or exclude detection of Staphylococcus argenteus.

    PubMed

    Bogestam, Katja; Vondracek, Martin; Karlsson, Mattias; Fang, Hong; Giske, Christian G

    2018-01-01

    Many countries using sensitive screening methods for detection of carriage of methicillin-resistant Staphylococcus aureus (MRSA) have a sustained low incidence of MRSA infections. For diagnostic laboratories with high sample volumes, MRSA screening requires stability, low maintenance and high performance at a low cost. Herein we designed oligonucleotides for a new nuc targeted hydrolysis probe PCR to replace the standard in-house nuc SybrGreen PCR assay. This new, more time-efficient, PCR assay resulted in a 40% increase in daily sample capacity, with maintained high specificity and sensitivity. The assay was also able to detect Staphylococcus aureus clonal cluster 75 (CC75) lineage strains, recently re-classified as Staphylococcus argenteus, with a sensitivity considerably increased compared to our previous assay. While awaiting consensus if the CC75 lineage of S. aureus should be considered as S. argenteus, and whether methicillin-resistant S. argenteus should be included in the MRSA definition, many diagnostic laboratories need to update their MRSA assay sensitivity/specificity towards this lineage/species. The MRSA screening assay presented in this manuscript is comprised of nuc oligonucleotides separately targeting S. aureus and CC75 lineage strains/S. argenteus, thus providing high user flexibility for the detection of CC75 lineage strains/S. argenteus.

  17. Tolerance of Bacteria to High Concentrations of NaCl and Glycerol in the Growth Medium

    PubMed Central

    Marshall, Betty J.; Ohye, D. F.; Christian, J. H. B.

    1971-01-01

    When compared at similar levels of water activity, glycerol was more inhibitory than sodium chloride to relatively salt-tolerant bacteria and less inhibitory than salt to salt-sensitive species. PMID:5549707

  18. An international prospective cohort study of mobile phone users and health (COSMOS): Factors affecting validity of self-reported mobile phone use.

    PubMed

    Toledano, Mireille B; Auvinen, Anssi; Tettamanti, Giorgio; Cao, Yang; Feychting, Maria; Ahlbom, Anders; Fremling, Karin; Heinävaara, Sirpa; Kojo, Katja; Knowles, Gemma; Smith, Rachel B; Schüz, Joachim; Johansen, Christoffer; Poulsen, Aslak Harbo; Deltour, Isabelle; Vermeulen, Roel; Kromhout, Hans; Elliott, Paul; Hillert, Lena

    2018-01-01

    This study investigates validity of self-reported mobile phone use in a subset of 75 993 adults from the COSMOS cohort study. Agreement between self-reported and operator-derived mobile call frequency and duration for a 3-month period was assessed using Cohen's weighted Kappa (κ). Sensitivity and specificity of both self-reported high (≥10 calls/day or ≥4h/week) and low (≤6 calls/week or <30min/week) mobile phone use were calculated, as compared to operator data. For users of one mobile phone, agreement was fair for call frequency (κ=0.35, 95% CI: 0.35, 0.36) and moderate for call duration (κ=0.50, 95% CI: 0.49, 0.50). Self-reported low call frequency and duration demonstrated high sensitivity (87% and 76% respectively), but for high call frequency and duration sensitivity was lower (38% and 56% respectively), reflecting a tendency for greater underestimation than overestimation. Validity of self-reported mobile phone use was lower in women, younger age groups and those reporting symptoms during/shortly after using a mobile phone. This study highlights the ongoing value of using self-report data to measure mobile phone use. Furthermore, compared to continuous scale estimates used by previous studies, categorical response options used in COSMOS appear to improve validity considerably, most likely by preventing unrealistically high estimates from being reported. Copyright © 2017 Elsevier GmbH. All rights reserved.

  19. Effect of Opuntia humifusa Supplementation and Acute Exercise on Insulin Sensitivity and Associations with PPAR-γ and PGC-1α Protein Expression in Skeletal Muscle of Rats

    PubMed Central

    Kang, Junyong; Lee, Junghun; Kwon, Daekeun; Song, Youngju

    2013-01-01

    This study examined whether Opuntia humifusa (O. humifusa), which is a member of the Cactaceae family, supplementation and acute swimming exercise affect insulin sensitivity and associations with PPAR-γ and PGC-1α protein expression in rats. Thirty-two rats were randomly divided into four groups (HS: high fat diet sedentary group, n = 8; HE: high fat diet acute exercise group, n = 8; OS: 5% O. humifusa supplemented high fat diet sedentary group, n = 8; OE: 5% O. humifusa supplemented high fat diet acute exercise group, n = 8). Rats in the HE and OE swam for 120 min. before being sacrificed. Our results indicated that serum glucose level, fasting insulin level and homeostasis model assessment of insulin resistance (HOMA-IR) in OS were significantly lower compared to those of the HS (p < 0.01, p < 0.05, p < 0.05). In addition, PPAR-γ protein expression in the OS and OE was significantly higher than that of the HS and HE, respectively (p < 0.05, p < 0.01). PGC-1α and GLUT-4 protein expressions in the OS were significantly higher compared to those of the HS (p < 0.05, p < 0.05). From these results, O. humifusa supplementation might play an important role for improving insulin sensitivity through elevation of PPAR-γ, PGC-1α, and GLUT-4 protein expression in rat skeletal muscle. PMID:23538842

  20. Assessment of Spanish Panel Reactive Antibody Calculator and Potential Usefulness.

    PubMed

    Asensio, Esther; López-Hoyos, Marcos; Romón, Íñigo; Ontañón, Jesús; San Segundo, David

    2017-01-01

    The calculated panel reactive of antibodies (cPRAs) necessary for kidney donor-pair exchange and highly sensitized programs are estimated using different panel reactive antibody (PRA) calculators based on big enough samples in Eurotransplant (EUTR), United Network for Organ Sharing (UNOS), and Canadian Transplant Registry (CTR) websites. However, those calculators can vary depending on the ethnic they are applied. Here, we develop a PRA calculator used in the Spanish Program of Transplant Access for Highly Sensitized patients (PATHI) and validate it with EUTR, UNOS, and CTR calculators. The anti-human leukocyte antigen (HLA) antibody profile of 42 sensitized patients on waiting list was defined, and cPRA was calculated with different PRA calculators. Despite different allelic frequencies derived from population differences in donor panel from each calculator, no differences in cPRA between the four calculators were observed. The PATHI calculator includes anti-DQA1 antibody profiles in cPRA calculation; however, no improvement in total cPRA calculation of highly sensitized patients was demonstrated. The PATHI calculator provides cPRA results comparable with those from EUTR, UNOS, and CTR calculators and serves as a tool to develop valid calculators in geographical and ethnic areas different from Europe, USA, and Canada.

  1. Low-cost polarization microscopy for cholesterol crystals

    NASA Astrophysics Data System (ADS)

    Kim, Kyungmin; Cho, Seonghee; Kim, Taehoon; Park, Hyoeun; Kim, Jinmoo; Lee, Seunghoon; Kang, Yeonsu; Chang, Kiyuk; Kim, Chulhong

    2018-02-01

    Because cholesterol crystals (Chcs) are a major cause of atherosclerosis, imaging Chcs in tissues with high sensitivity and specificity is important in diagnosing and predicting atherosclerosis. Polarizing microscopy (PM) has been widely used to image crystalline materials in tissues, but it has been difficult to distinguish Chcs from other crystalline materials in tissues. Thus, various methods such as fluorescent dye staining, Raman spectroscopy, and two-photon microscopy (TPM) have been developed to image Chcs with high sensitivity and specificity. However, these methods require expensive equipment or complex processes. Therefore, we have developed a low-cost, easy-to-use PM system using an LED light source that can distinguish Chcs from other crystalline materials with high sensitivity and specificity. Due to the nature of the LED spectrum in our system, collagen is displayed in yellow and Chcs in blue. In addition, we have improved the sensitivity and specificity by creating an aqueous condition on the sample. In the aqueous state, signals of yellowish collagen fibers were reduced and signals of Chcs were highlighted. The Chcs detection capability of our system was verified compared with the TPM image. In addition, clinical feasibility was shown by comparison with existing histological methods.

  2. Highly sensitive three-dimensional interdigitated microelectrode for microparticle detection using electrical impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Chang, Fu-Yu; Chen, Ming-Kun; Wang, Min-Haw; Jang, Ling-Sheng

    2016-02-01

    Cell impedance analysis is widely used for monitoring biological and medical reactions. In this study, a highly sensitive three-dimensional (3D) interdigitated microelectrode (IME) with a high aspect ratio on a polyimide (PI) flexible substrate was fabricated for microparticle detection (e.g. cell quantity detection) using electroforming and lithography technology. 3D finite element simulations were performed to compare the performance of the 3D IME (in terms of sensitivity and signal-to-noise ratio) to that of a planar IME for particles in the sensing area. Various quantities of particles were captured in Dulbecco’s modified Eagle medium and their impedances were measured. With the 3D IME, the particles were arranged in the gap, not on the electrode, avoiding the noise due to particle position. For the maximum particle quantities, the results show that the 3D IME has at least 5-fold higher sensitivity than that of the planar IME. The trends of impedance magnitude and phase due to particle quantity were verified using the equivalent circuit model. The impedance (1269 Ω) of 69 particles was used to estimate the particle quantity (68 particles) with 98.6% accuracy using a parabolic regression curve at 500 kHz.

  3. Auditory evoked potential could reflect emotional sensitivity and impulsivity

    PubMed Central

    Kim, Ji Sun; Kim, Sungkean; Jung, Wookyoung; Im, Chang-Hwan; Lee, Seung-Hwan

    2016-01-01

    Emotional sensitivity and impulsivity could cause interpersonal conflicts and neuropsychiatric problems. Serotonin is correlated with behavioral inhibition and impulsivity. This study evaluated whether the loudness dependence of auditory evoked potential (LDAEP), a potential biological marker of central serotonergic activity, could reflect emotional sensitivity and impulsivity. A total of 157 healthy individuals were recruited, who performed LDAEP and Go/Nogo paradigms during electroencephalogram measurement. Barratt impulsivity scale (BIS), Conners’ Adult ADHD rating scale (CAARS), and affective lability scale (ALS) were evaluated. Comparison between low and high LDAEP groups was conducted for behavioural, psychological, and event-related potential (ERP) measures. The high LDAEP group showed significantly increased BIS, a subscale of the CAARS, ALS, and false alarm rate of Nogo stimuli compared to the low LDAEP group. LDAEP showed significant positive correlations with the depression scale, ALS scores, subscale of the CAARS and Nogo-P3 amplitude. In the source activity of Nogo-P3, the cuneus, lingual gyrus, and precentral gyrus activities were significantly increased in the high LDAEP group. Our study revealed that LDAEP could reflect emotional sensitivity and impulsivity. LDAEP, an auditory evoked potential could be a useful tool to evaluate emotional regulation. PMID:27910865

  4. Perovskite nanoparticle-sensitized Ga 2O 3 nanorod arrays for CO detection at high temperature

    DOE PAGES

    Lin, Hui -Jan; Baltrus, John P.; Gao, Haiyong; ...

    2016-04-04

    Here, noble metal nanoparticles are extensively used for sensitizing metal oxide chemical sensors through the catalytic spillover mechanism. However, due to earth-scarcity and high cost of noble metals, finding replacements presents a great economic benefit. Besides, high temperature and harsh environment sensor applications demand material stability under conditions approaching thermal and chemical stability limits of noble metals. In this study, we employed thermally stable perovskite-type La 0.8Sr 0.2FeO 3 (LSFO) nanoparticle surface decoration on Ga 2O 3 nanorod array gas sensors and discovered an order of magnitude enhanced sensitivity to carbon monoxide at 500 °C. The LSFO nanoparticle catalysts wasmore » of comparable performance to that achieved by Pt nanoparticles, with a much lower weight loading than Pt. Detailed electron microscopy and X-ray photoelectron spectroscopy studies suggested the LSFO nanoparticle sensitization effect is attributed to a spillover-like effect associated with the gas-LSFO-Ga 2O 3 triple-interfaces that spread the negatively charged surface oxygen ions from LSFO nanoparticles surfaces over to β-Ga 2O 3 nanorod surfaces with faster surface CO oxidation reactions.« less

  5. Perovskite Nanoparticle-Sensitized Ga2O3 Nanorod Arrays for CO Detection at High Temperature.

    PubMed

    Lin, Hui-Jan; Baltrus, John P; Gao, Haiyong; Ding, Yong; Nam, Chang-Yong; Ohodnicki, Paul; Gao, Pu-Xian

    2016-04-13

    Noble metal nanoparticles are extensively used for sensitizing metal oxide chemical sensors through the catalytic spillover mechanism. However, due to earth-scarcity and high cost of noble metals, finding replacements presents a great economic benefit. Besides, high temperature and harsh environment sensor applications demand material stability under conditions approaching thermal and chemical stability limits of noble metals. In this study, we employed thermally stable perovskite-type La(0.8)Sr(0.2)FeO3 (LSFO) nanoparticle surface decoration on Ga2O3 nanorod array gas sensors and discovered an order of magnitude enhanced sensitivity to carbon monoxide at 500 °C. The LSFO nanoparticle catalysts was of comparable performance to that achieved by Pt nanoparticles, with a much lower weight loading than Pt. Detailed electron microscopy and X-ray photoelectron spectroscopy studies suggested the LSFO nanoparticle sensitization effect is attributed to a spillover-like effect associated with the gas-LSFO-Ga2O3 triple-interfaces that spread the negatively charged surface oxygen ions from LSFO nanoparticles surfaces over to β-Ga2O3 nanorod surfaces with faster surface CO oxidation reactions.

  6. Highly anisotropic black phosphorous-graphene hybrid architecture for ultrassensitive plasmonic biosensing: Theoretical insight

    NASA Astrophysics Data System (ADS)

    Yuan, Yufeng; Yu, Xiantong; Ouyang, Qingling; Shao, Yonghong; Song, Jun; Qu, Junle; Yong, Ken-Tye

    2018-04-01

    This study proposed a novel highly anisotropic surface plasmon resonance (SPR) biosensor employing emerging 2D black phosphorus (BP) and graphene atomic layers. Light absorption and energy loss were well balanced by optimizing gold film thickness and number of BP layers to generate the strongest SPR excitation. The proposed SPR biosensor was designed by the phase-modulation approach and is more sensitive to biomolecule bindings, providing 3 orders of magnitude higher sensitivity than the red-shift in SPR angle. Our results show the optimized configuration was 48 nm Au film coated with 4-layer BP crystal to produce the sharpest phase variation (up to 89.8975°), and lowest minimum reflectivity (1.9119  ×  10-7). Detection sensitivity up to 7.4914  ×  104 degree/refractive index unit is almost 4.5 times enhanced compared to monolayer graphene-based SPR sensors with 48 nm Au film. The anisotropic BP layers act as a polarizer, so the proposed SPR biosensor would exhibit optically tunable detection sensitivity, making it a promising candidate for exploring highly anisotropic platforms in biosensing.

  7. A highly sensitive monoclonal antibody based biosensor for quantifying 3-5 ring polycyclic aromatic hydrocarbons (PAHs) in aqueous environmental samples.

    PubMed

    Li, Xin; Kaattari, Stephen L; Vogelbein, Mary A; Vadas, George G; Unger, Michael A

    2016-03-01

    Immunoassays based on monoclonal antibodies (mAbs) are highly sensitive for the detection of polycyclic aromatic hydrocarbons (PAHs) and can be employed to determine concentrations in near real-time. A sensitive generic mAb against PAHs, named as 2G8, was developed by a three-step screening procedure. It exhibited nearly uniformly high sensitivity against 3-ring to 5-ring unsubstituted PAHs and their common environmental methylated PAHs, with IC 50 values between 1.68-31 μg/L (ppb). 2G8 has been successfully applied on the KinExA Inline Biosensor system for quantifying 3-5 ring PAHs in aqueous environmental samples. PAHs were detected at a concentration as low as 0.2 μg/L. Furthermore, the analyses only required 10 min for each sample. To evaluate the accuracy of the 2G8-based biosensor, the total PAH concentrations in a series of environmental samples analyzed by biosensor and GC-MS were compared. In most cases, the results yielded a good correlation between methods. This indicates that generic antibody 2G8 based biosensor possesses significant promise for a low cost, rapid method for PAH determination in aqueous samples.

  8. Semi-continuous ultrasonic sounding and changes of ultrasonic signal characteristics as a sensitive tool for the evaluation of ongoing microstructural changes of experimental mortar bars tested for their ASR potential.

    PubMed

    Lokajíček, T; Kuchařová, A; Petružálek, M; Šachlová, Š; Svitek, T; Přikryl, R

    2016-09-01

    Semi-continuous ultrasonic sounding of experimental mortar bars used in the accelerated alkali silica reactivity laboratory test (ASTM C1260) is proposed as a supplementary measurement technique providing data that are highly sensitive to minor changes in the microstructure of hardening/deteriorating concrete mixture. A newly designed, patent pending, heating chamber was constructed allowing ultrasonic sounding of mortar bars, stored in accelerating solution without necessity to remove the test specimens from the bath during the measurement. Subsequent automatic data analysis of recorded ultrasonic signals proved their high correlation to the measured length changes (expansion) and their high sensitivity to microstructural changes. The changes of P-wave velocity, and of the energy, amplitude, and frequency of ultrasonic signal, were in the range of 10-80%, compared to 0.51% change of the length. Results presented in this study thus show that ultrasonic sounding seems to be more sensitive to microstructural changes due to ongoing deterioration of concrete microstructure by alkali-silica reaction than the dimensional changes. Copyright © 2016. Published by Elsevier B.V.

  9. Children's Reward and Punishment Sensitivity Moderates the Association of Negative and Positive Parenting Behaviors in Child ADHD Symptoms.

    PubMed

    Li, James J

    2018-03-20

    Atypical reward processing, including abnormal reward responsivity and sensitivity to punishment, has long been implicated in the etiology of ADHD. However, little is known about how these facets of behavior interact with positive (e.g., warmth, praise) and negative (e.g., hostility, harsh discipline) parenting behavior in the early expression of ADHD symptoms in young children. Understanding the interplay between children's reward processing and parenting may be crucial for identifying specific treatment targets in psychosocial interventions for ADHD, especially given that not all children benefit from contingency-based treatments (e.g., parent management training). The study consisted of a sample of kindergarten children (N = 201, 55% male) and their parents, who completed questionnaires about their parenting practices, their child's behaviors and participated in an observed parent-child play task in the laboratory. Children's reward responsivity and sensitivity to punishment were positively associated with child ADHD symptoms. However, children with high reward responsivity had more symptoms of ADHD but only under conditions of low negative parenting (self-reported and observed) and high self-reported positive parenting, compared to children with low reward responsivity. Children with high sensitivity to punishment had more ADHD symptoms relative to children with low sensitivity to punishment, but only under conditions in which observed praise was infrequent. Results provide evidence that individual differences in sensitivity to reward/punishment may be an important of marker of risk for ADHD, but also highlights how children's responses to positive and negative parenting behavior may vary by children's sensitivities. Clinical and treatment implications are discussed.

  10. Simplified HCC-ART score for highly sensitive detection of small-sized and early-stage hepatocellular carcinoma in the widely used Okuda, CLIP, and BCLC staging systems.

    PubMed

    Attallah, Abdelfattah M; Omran, Mohamed M; Attallah, Ahmed A; Abdelrazek, Mohamed A; Farid, Khaled; El-Dosoky, Ibrahim

    2017-04-01

    Small-sized HCC can be effectively cured by surgery with good clinical outcomes. A highly sensitive HCC α-fetoprotein routine test (HCC-ART) for HCC diagnosis as well as a simplied form of the HCC-ART were reported in the British Journal of Cancer. Here, we verified and studied the applicability of the HCC-ART to the detection of early-stage HCC. 341 cirrhotic patients and 318 HCC patients were included in this study. For each, the HCC-ART score was calculated, and then the sensitivity, specificity, and results of an ROC curve analysis were compared between the HCC-ART and AFP when these biomarkers were used to detect small-sized HCC. Different HCC-ART cutoffs were set for the detection of different tumor sizes. The HCC-ART (AUC = 0.871, 70% sensitivity, 97% specificity) and the simplified HCC-ART (AUC = 0.934, 82% sensitivity, 100% specificity) were found to have high predictive power when attempting to separate cirrhotic patients from those with small-sized HCC. The simplified HCC-ART score was superior to AFP for determining stages according to the early Okuda (0.950 AUC, 84% sensitivity, 99% specificity), CLIP (0.945 AUC, 84% sensitivity, 99% specificity), and BCLC (1.000 AUC, 100% sensitivity, 99% specificity) staging systems. The simplified HCC-ART score was more strongly correlated than AFP and other staging systems with HCC tumor size (P < 0.0001; r = 0.8). The HCC-ART is superior to AFP for diagnosing early-stage HCC. Due to its advantages of minimal variability and a wide continuous scale for assessing HCC severity, the simplified HCC-ART has the potential to be more widely used than the original HCC-ART.

  11. Low Dose High Energy X-ray In-Line Phase Sensitive Imaging Prototype: Investigation of Optimal Geometric Conditions and Design Parameters

    PubMed Central

    Ghani, Muhammad. U.; Yan, Aimin; Wong, Molly. D.; Li, Yuhua; Ren, Liqiang; Wu, Xizeng; Liu, Hong

    2016-01-01

    The objective of this study was to investigate the optimization of a high energy in-line phase sensitive x-ray imaging prototype under different geometric and operating conditions for mammography application. A phase retrieval algorithm based on phase attenuation duality (PAD) was applied to the phase contrast images acquired by the prototype. Imaging performance was investigated at four magnification values of 1.67, 2, 2.5 and 3 using an acrylic edge, an American College of Radiology (ACR) mammography phantom and contrast detail (CD) phantom with tube potentials of 100, 120 and 140 kVp. The ACR and CD images were acquired at the same mean glandular dose (MGD) of 1.29 mGy with a computed radiography (CR) detector of 43.75 µm pixel pitch at a fixed source to image distance (SID) of 170 cm. The x-ray tube focal spot size was kept constant as 7 µm while a 2.5 mm thick aluminum (Al) filter was used for beam hardening. The performance of phase contrast and phase retrieved images were compared with computer simulations based on the relative phase contrast factor (RPF) at high x-ray energies. The imaging results showed that the x-ray tube operated at 100 kVp under the magnification of 2.5 exhibits superior imaging performance which is in accordance to the computer simulations. As compared to the phase contrast images, the phase retrieved images of the ACR and CD phantoms demonstrated improved imaging contrast and target discrimination. We compared the CD phantom images acquired in conventional contact mode with and without the anti-scatter grid using the same prototype at 1.295 mGy and 2.59 mGy using 40 kVp, a 25 µm rhodium (Rh) filter. At the same radiation dose, the phase sensitive images provided improved detection capabilities for both the large and small discs, while compared to the double dose image acquired in conventional mode, the observer study also indicated that the phase sensitive images provided improved detection capabilities for the large discs. This study therefore validates the potential of using high energy phase contrast x-ray imaging to improve lesion detection and reduce radiation dose for clinical applications such as mammography. PMID:26756405

  12. Accuracy of dementia diagnosis: a direct comparison between radiologists and a computerized method.

    PubMed

    Klöppel, Stefan; Stonnington, Cynthia M; Barnes, Josephine; Chen, Frederick; Chu, Carlton; Good, Catriona D; Mader, Irina; Mitchell, L Anne; Patel, Ameet C; Roberts, Catherine C; Fox, Nick C; Jack, Clifford R; Ashburner, John; Frackowiak, Richard S J

    2008-11-01

    There has been recent interest in the application of machine learning techniques to neuroimaging-based diagnosis. These methods promise fully automated, standard PC-based clinical decisions, unbiased by variable radiological expertise. We recently used support vector machines (SVMs) to separate sporadic Alzheimer's disease from normal ageing and from fronto-temporal lobar degeneration (FTLD). In this study, we compare the results to those obtained by radiologists. A binary diagnostic classification was made by six radiologists with different levels of experience on the same scans and information that had been previously analysed with SVM. SVMs correctly classified 95% (sensitivity/specificity: 95/95) of sporadic Alzheimer's disease and controls into their respective groups. Radiologists correctly classified 65-95% (median 89%; sensitivity/specificity: 88/90) of scans. SVM correctly classified another set of sporadic Alzheimer's disease in 93% (sensitivity/specificity: 100/86) of cases, whereas radiologists ranged between 80% and 90% (median 83%; sensitivity/specificity: 80/85). SVMs were better at separating patients with sporadic Alzheimer's disease from those with FTLD (SVM 89%; sensitivity/specificity: 83/95; compared to radiological range from 63% to 83%; median 71%; sensitivity/specificity: 64/76). Radiologists were always accurate when they reported a high degree of diagnostic confidence. The results show that well-trained neuroradiologists classify typical Alzheimer's disease-associated scans comparable to SVMs. However, SVMs require no expert knowledge and trained SVMs can readily be exchanged between centres for use in diagnostic classification. These results are encouraging and indicate a role for computerized diagnostic methods in clinical practice.

  13. Accuracy of dementia diagnosis—a direct comparison between radiologists and a computerized method

    PubMed Central

    Stonnington, Cynthia M.; Barnes, Josephine; Chen, Frederick; Chu, Carlton; Good, Catriona D.; Mader, Irina; Mitchell, L. Anne; Patel, Ameet C.; Roberts, Catherine C.; Fox, Nick C.; Jack, Clifford R.; Ashburner, John; Frackowiak, Richard S. J.

    2008-01-01

    There has been recent interest in the application of machine learning techniques to neuroimaging-based diagnosis. These methods promise fully automated, standard PC-based clinical decisions, unbiased by variable radiological expertise. We recently used support vector machines (SVMs) to separate sporadic Alzheimer's disease from normal ageing and from fronto-temporal lobar degeneration (FTLD). In this study, we compare the results to those obtained by radiologists. A binary diagnostic classification was made by six radiologists with different levels of experience on the same scans and information that had been previously analysed with SVM. SVMs correctly classified 95% (sensitivity/specificity: 95/95) of sporadic Alzheimer's disease and controls into their respective groups. Radiologists correctly classified 65–95% (median 89%; sensitivity/specificity: 88/90) of scans. SVM correctly classified another set of sporadic Alzheimer's disease in 93% (sensitivity/specificity: 100/86) of cases, whereas radiologists ranged between 80% and 90% (median 83%; sensitivity/specificity: 80/85). SVMs were better at separating patients with sporadic Alzheimer's disease from those with FTLD (SVM 89%; sensitivity/specificity: 83/95; compared to radiological range from 63% to 83%; median 71%; sensitivity/specificity: 64/76). Radiologists were always accurate when they reported a high degree of diagnostic confidence. The results show that well-trained neuroradiologists classify typical Alzheimer's disease-associated scans comparable to SVMs. However, SVMs require no expert knowledge and trained SVMs can readily be exchanged between centres for use in diagnostic classification. These results are encouraging and indicate a role for computerized diagnostic methods in clinical practice. PMID:18835868

  14. Detection of NMR signals with a radio-frequency atomic magnetometer.

    PubMed

    Savukov, I M; Seltzer, S J; Romalis, M V

    2007-04-01

    We demonstrate detection of proton NMR signals with a radio-frequency (rf) atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz1/2 using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.

  15. Detecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging

    PubMed Central

    Dou, Shewei; Bai, Yan; Shandil, Ankit; Ding, Degang; Shi, Dapeng; Haacke, E Mark; Wang, Meiyun

    2017-01-01

    Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resonance imaging, diffusion-weighted imaging, and susceptibility-weighted imaging were performed on all the patients. One hundred and twelve prostatic calcifications were detected in 87 patients. The sensitivities and specificities of the conventional magnetic resonance imaging, apparent diffusion coefficient, and susceptibility-filtered phase images in detecting prostate cancer and prostatic calcifications were calculated. McNemar's Chi-square test was used to compare the differences in sensitivities and specificities between the techniques. The results showed that the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic cancer were greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). In addition, the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic calcifications were comparable to that of computed tomography and greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). Given the high incidence of susceptibility-weighted imaging (SWI) abnormality in prostate cancer, we conclude that susceptibility-weighted imaging is more sensitive and specific than conventional magnetic resonance imaging, diffusion-weighted imaging, and computed tomography in detecting prostate cancer. Furthermore, susceptibility-weighted imaging can identify prostatic calcifications similar to computed tomography, and it is much better than conventional magnetic resonance imaging and diffusion-weighted imaging. PMID:27004542

  16. Detecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging.

    PubMed

    Dou, Shewei; Bai, Yan; Shandil, Ankit; Ding, Degang; Shi, Dapeng; Haacke, E Mark; Wang, Meiyun

    2017-01-01

    Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resonance imaging, diffusion-weighted imaging, and susceptibility-weighted imaging were performed on all the patients. One hundred and twelve prostatic calcifications were detected in 87 patients. The sensitivities and specificities of the conventional magnetic resonance imaging, apparent diffusion coefficient, and susceptibility-filtered phase images in detecting prostate cancer and prostatic calcifications were calculated. McNemar's Chi-square test was used to compare the differences in sensitivities and specificities between the techniques. The results showed that the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic cancer were greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). In addition, the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic calcifications were comparable to that of computed tomography and greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). Given the high incidence of susceptibility-weighted imaging (SWI) abnormality in prostate cancer, we conclude that susceptibility-weighted imaging is more sensitive and specific than conventional magnetic resonance imaging, diffusion-weighted imaging, and computed tomography in detecting prostate cancer. Furthermore, susceptibility-weighted imaging can identify prostatic calcifications similar to computed tomography, and it is much better than conventional magnetic resonance imaging and diffusion-weighted imaging.

  17. Accuracy of line probe assays for the diagnosis of pulmonary and multidrug-resistant tuberculosis: a systematic review and meta-analysis

    PubMed Central

    Cudahy, Patrick G.T; Schumacher, Samuel G.; Steingart, Karen R.; Pai, Madhukar; Denkinger, Claudia M.

    2017-01-01

    Only 25% of multidrug-resistant tuberculosis (MDR-TB) cases are currently diagnosed. Line probe assays (LPAs) enable rapid drug-susceptibility testing for rifampicin (RIF) and isoniazid (INH) resistance and Mycobacterium tuberculosis detection. Genotype MTBDRplusV1 was WHO-endorsed in 2008 but newer LPAs have since been developed. This systematic review evaluated three LPAs: Hain Genotype MTBDRplusV1, MTBDRplusV2 and Nipro NTM+MDRTB. Study quality was assessed with QUADAS-2. Bivariate random-effects meta-analyses were performed for direct and indirect testing. Results for RIF and INH resistance were compared to phenotypic and composite (incorporating sequencing) reference standards. M. tuberculosis detection results were compared to culture. 74 unique studies were included. For RIF resistance (21 225 samples), pooled sensitivity and specificity (with 95% confidence intervals) were 96.7% (95.6–97.5%) and 98.8% (98.2–99.2%). For INH resistance (20 954 samples), pooled sensitivity and specificity were 90.2% (88.2–91.9%) and 99.2% (98.7–99.5%). Results were similar for direct and indirect testing and across LPAs. Using a composite reference standard, specificity increased marginally. For M. tuberculosis detection (3451 samples), pooled sensitivity was 94% (89.4–99.4%) for smear-positive specimens and 44% (20.2–71.7%) for smear-negative specimens. In patients with pulmonary TB, LPAs have high sensitivity and specificity for RIF resistance and high specificity and good sensitivity for INH resistance. This meta-analysis provides evidence for policy and practice. PMID:28100546

  18. The role of cone-beam breast-CT for breast cancer detection relative to breast density.

    PubMed

    Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe

    2017-12-01

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (p<0.001). • Specificity was higher for mammography than CBBCT in both density types (p<0.05). • AUC was larger for mammography than CBBCT in both density types (p<0.001).

  19. Comparative theoretical studies of differently bridged nitramino-substituted ditetrazole 2-N-oxides with high detonation performance and an oxygen balance of around zero.

    PubMed

    Wu, Qiong; Kou, Bo; Hang, Zusheng; Zhu, Weihua

    2017-06-01

    In this work, six (A-F) nitramino (-NHNO 2 )-substituted ditetrazole 2-N-oxides with different bridging groups (-CH 2 -, -CH 2 -CH 2 -, -NH-, -N=N-, and -NH-NH-) were designed. The six compounds were based on the parent compound tetrazole 2-N-oxide, which possesses a high oxygen balance and high density. The structure, heat of formation, density, detonation properties (detonation velocity D and detonation pressure P), and the sensitivity of each compound was investigated systematically via density functional theory, by studying the electrostatic potential, and using molecular mechanics. The results showed that compounds A-F all have outstanding energetic properties (D: 9.1-10.0 km/s; P: 38.0-46.7 GPa) and acceptable sensitivities (h 50 : 28-37 cm). The bridging group present was found to greatly affect the detonation performance of each ditetrazole 2-N-oxide, and the compound with the -NH-NH- bridging group yielded the best results. Indeed, this compound (F) was calculated to have comparable sensitivity to the famous and widely used high explosive 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX), but with values of D and P that were about 8.7% and 19.4% higher than those for HMX, respectively. The present study shows that tetrazole 2-N-oxide is a useful parent compound which could potentially be used in the design of new and improved high-energy compounds to replace existing energetic compounds such as HMX.

  20. Automated Processing of Dynamic Contrast-Enhanced MRI: Correlation of Advanced Pharmacokinetic Metrics with Tumor Grade in Pediatric Brain Tumors.

    PubMed

    Vajapeyam, S; Stamoulis, C; Ricci, K; Kieran, M; Poussaint, T Young

    2017-01-01

    Pharmacokinetic parameters from dynamic contrast-enhanced MR imaging have proved useful for differentiating brain tumor grades in adults. In this study, we retrospectively reviewed dynamic contrast-enhanced perfusion data from children with newly diagnosed brain tumors and analyzed the pharmacokinetic parameters correlating with tumor grade. Dynamic contrast-enhanced MR imaging data from 38 patients were analyzed by using commercially available software. Subjects were categorized into 2 groups based on pathologic analyses consisting of low-grade (World Health Organization I and II) and high-grade (World Health Organization III and IV) tumors. Pharmacokinetic parameters were compared between the 2 groups by using linear regression models. For parameters that were statistically distinct between the 2 groups, sensitivity and specificity were also estimated. Eighteen tumors were classified as low-grade, and 20, as high-grade. Transfer constant from the blood plasma into the extracellular extravascular space (K trans ), rate constant from extracellular extravascular space back into blood plasma (K ep ), and extracellular extravascular volume fraction (V e ) were all significantly correlated with tumor grade; high-grade tumors showed higher K trans , higher K ep , and lower V e . Although all 3 parameters had high specificity (range, 82%-100%), K ep had the highest specificity for both grades. Optimal sensitivity was achieved for V e , with a combined sensitivity of 76% (compared with 71% for K trans and K ep ). Pharmacokinetic parameters derived from dynamic contrast-enhanced MR imaging can effectively discriminate low- and high-grade pediatric brain tumors. © 2017 by American Journal of Neuroradiology.

Top