LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report
NASA Technical Reports Server (NTRS)
Oldham, Timothy; Pellish, Jonathan; Boutte, Alvin
2012-01-01
This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.
Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions
NASA Technical Reports Server (NTRS)
McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.
2012-01-01
Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.
Selective effects of two systemic fungicides on soil fungi.
Abdel-Fattah, H M; Abdel-Kader, M I; Hamida, S
1982-08-20
BAS 317 00F was not toxic to the total count of fungi after 2 days but was regularly significantly toxic at the three doses after 5, 20 and 40 days and toxic at the low and the high doses after 80 days. In the agar medium, it was toxic to the counts of total fungi. Aspergillus, A. terreus, Rhizopus oryzae and Mucor racemosus at the high dose. Only the mycelial growth of Trichoderma viride which was significantly inhibited by the three doses when this fungicide was added to the liquid medium. Polyram-Combi induced two effects on the total population of soil fungi. One inhibitory and this was demonstrated almost regularly after 2, 10 and 40 days and the other stimulatory after 80 days of treatment with the low and the high doses. In the agar medium, this fungicide was very toxic to total fungi and to almost all fungal genera and species at the three doses. Several fungi could survive the high dose. In liquid medium, the test fungi showed variable degree of sensitivity and the most sensitive was Gliocladium roseum which was completely eradicated by the three doses.
ELDRS Characterization for a Very High Dose Mission
NASA Technical Reports Server (NTRS)
Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee
2010-01-01
Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.
NASA Astrophysics Data System (ADS)
Rieder, H. E.; Staehelin, J.; Weihs, P.; Vuilleumier, L.; Maeder, J. A.; Holawe, F.; Blumthaler, M.; Lindfors, A.; Peter, T.; Simic, S.; Spichtinger, P.; Wagner, J. E.; Walker, D.; Ribatet, M.
2010-10-01
This work investigates the occurrence frequency of days with high erythemal UV doses at three stations in Switzerland and Austria (Davos, Hoher Sonnblick and Vienna) for the time period 1974-2003. While several earlier studies have reported on increases in erythemal UV dose up to 10% during the last decades, this study focuses on days with high erythemal UV dose, which is defined as a daily dose at least 15% higher than for 1950s clear-sky conditions (which represent preindustrial conditions with respect to anthropogenic chlorine). Furthermore, the influence of low column ozone, clear-sky/partly cloudy conditions and surface albedo on UV irradiance has been analyzed on annual and seasonal basis. The results of this study show that in the Central Alpine Region the number of days with high UV dose increased strongly in the early 1990s. A large fraction of all days with high UV dose occurring in the period 1974-2003 was found especially during the years 1994-2003, namely 40% at Davos, 54% at Hoher Sonnblick and 65% at Vienna. The importance of total ozone, clear-sky/partly cloudy conditions and surface albedo (e.g. in dependence of snow cover) varies strongly among the seasons. However, overall the interplay of low total ozone and clear-sky/partly cloudy conditions led to the largest fraction of days showing high erythemal UV dose. Furthermore, an analysis of the synoptic weather situation showed that days with high erythemal UV dose, low total ozone and high relative sunshine duration occur at all three stations more frequently during situations with low pressure gradients or southerly advection.
Huh, Seung Jae; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Eun; Kang, Min Kyu; Shin, Seong Soo; Shin, Kyung Hwan; Kim, Bokyung; Park, Won; Han, Youngyih
2003-03-01
To investigate the correlation between late rectal complications and rectal dose in cervix cancer patients treated with high-dose-rate intracavitary radiotherapy (HDR ICR) and to analyze factors reducing rectal complications. A total of 136 patients with cervix cancer who were treated with external beam radiotherapy (EBRT) and HDR ICR from 1995 to 1999 were retrospectively analyzed. Radiotherapy (RT) consisted of EBRT plus HDR ICR. The median EBRT dose was 50.4 Gy, and midline block was done after 30-50 Gy of EBRT. A total of six fractions of HDR ICR with 4 Gy fraction size each were applied twice per week to the A point. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. In vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 26 months (range 6-60 months). A total of 16 patients (12%) experienced rectal bleeding, which occurred 4-33 months (median 11 months) after the completion of RT. The calculated rectal doses did not differ in patients with rectal bleeding and those without, but the measured rectal doses were higher in affected patients. The differences of the measured ICR fractional rectal dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose exceeded 16 Gy, the ratio of the measured rectal dose to A point dose was > 70%; when the measured rectal BED exceeded 110 Gy(3), a high possibility of late rectal complications could be found. In vivo dosimetry using TLD during HDR ICR was a good predictor of late rectal complications. Hence, if data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.
Bain, David; Buttemer, William A; Astheimer, Lee; Fildes, Karen; Hooper, Michael J
2004-01-01
The central bearded dragon (Pogona vitticeps) is a medium-sized lizard that is common in semiarid habitats in Australia and that potentially is at risk of fenitrothion exposure from use of the chemical in plague locust control. We examined the effects of single sublethal doses of this organophosphate (OP; low dose = 2.0 mg/kg; high dose = 20 mg/kg; control = vehicle alone) on lizard thermal preference, standard metabolic rate, and prey-capture ability. We also measured activities of plasma total cholinesterase (ChE) and acetylcholinesterase before and at 0, 2, 8, 24, 120, and 504 h after OP dosing. Predose plasma total ChE activity differed significantly between sexes and averaged 0.66 +/- 0.06 and 0.45 +/- 0.06 micromol/min/ml for males and females, respectively. Approximately 75% of total ChE activity was attributable to butyrylcholinesterase. Peak ChE inhibition reached 19% 2 h after OP ingestion in the low-dose group, and 68% 8 h after ingestion in high-dose animals. Neither OP doses significantly affected diurnal body temperature, standard metabolic rate, or feeding rate. Plasma total ChE levels remained substantially depressed up to 21 d after dosing in the high-dose group, making this species a useful long-term biomonitor of OP exposure in its habitat.
Hashimoto, Koshi; Ota, Masaki; Irie, Tadanobu; Takata, Daisuke; Nakajima, Tadashi; Kaneko, Yoshiaki; Tanaka, Yuko; Matsumoto, Shunichi; Nakajima, Yasuyo; Kurabayashi, Masahiko; Oyama, Tetsunari; Takeyoshi, Izumi; Mori, Masatomo; Yamada, Masanobu
2015-01-01
Amiodarone is used commonly and effectively in the treatment of arrhythmia; however, it may cause thyrotoxicosis categorized into two types: iodine-induced hyperthyroidism (type 1 amiodarone-induced thyrotoxicosis (AIT)) and destructive thyroiditis (type 2 AIT). We experienced a case of type 2 AIT, in which high-dose steroid was administered intravenously, and we finally decided to perform total thyroidectomy, resulting in a complete cure of the AIT. Even though steroid had been administered to the patient (maximum 80 mg of prednisolone), the operation was performed safely and no acute adrenal crisis as steroid withdrawal syndrome was found after the operation. Few cases of type 2 AIT that underwent total thyroidectomy with high-dose steroid administration have been reported. The current case suggests that total thyroidectomy should be taken into consideration for patients with AIT who cannot be controlled by medical treatment and even in those under high-dose steroid administration. PMID:25664188
Suh, Yang-Gun; Lee, Ik Jae; Koom, Wong Sub; Cha, Jihye; Lee, Jong Young; Kim, Soo Kon; Lee, Chang Geol
2014-06-01
In this study, we investigated the effects of radiotherapy ≥60 Gy in the setting of concurrent chemo-radiotherapy for treating patients with Stages II-III esophageal cancer. A total of 126 patients treated with 5-fluorouracilbased concurrent chemo-radiotherapy between January 1998 and February 2008 were retrospectively reviewed. Among these patients, 49 received a total radiation dose of <60 Gy (standard-dose group), while 77 received a total radiation dose of ≥60 Gy (high-dose group). The median doses in the standard- and high-dose groups were 54 Gy (range, 45-59.4 Gy) and 63 Gy (range, 60-81 Gy), respectively. The high-dose group showed significantly improved locoregional control (2-year locoregional control rate, 69 versus 32%, P < 0.01) and progression-free survival (2-year progression-free survival, 47 versus 20%, P = 0.01) than the standard-dose group. Median overall survival in the high- and the standard-dose groups was 28 and 18 months, respectively (P = 0.26). In multivariate analysis, 60 Gy or higher radiotherapy was a significant prognostic factor for improved locoregional control, progression-free survival and overall survival. No significant differences were found in frequencies of late radiation pneumonitis, post-treatment esophageal stricture or treatment-related mortality between the two groups. High-dose radiotherapy of 60 Gy or higher with concurrent chemotherapy improved locoregional control and progression-free survival without a significant increase of in treatment-related toxicity in patients with Stages II-III esophageal cancer. Our study could provide the basis for future randomized clinical trials. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Sibonga, J. D.; Iwaniec, U.; Wu, H.
2011-01-01
PURPOSE: We obtained bone tissue to evaluate the collateral effects of experiments designed to investigate molecular mechanisms of radio-adaptation in a mouse model. Radio-adaptation describes a process by which the prior exposure to low dose radiation can protect against the toxic effect of a subsequent high dose exposure. In the radio-adaptation experiments, C57Bl/6 mice were exposed to either a Sham or a priming Low Dose (5 cGy) of Cs-137 gamma rays before being exposed to either a Sham or High Dose (6 Gy) 24 hours later. ANALYSIS: Bone tissue were obtained from two experiments where mice were sacrificed at 3 days (n=3/group, 12 total) and at 14 days (n=6/group, 24 total) following high dose exposure. Tissues were analyzed to 1) evaluate a radio-adaptive response in bone tissue and 2) describe cellular and microstructural effects for two skeletal sites with different rates of bone turnover. One tibia and one lumbar vertebrae (LV2), collected at the 3-day time-point, were analyzed by bone histomorphometry and micro-CT to evaluate the cellular response and any evidence of microarchitectural impact. Likewise, tibia and LV2, collected at the 14-day time-point, were analyzed by micro-CT alone to evaluate resulting changes to bone structure and microarchitecture. The data were analyzed by 2-way ANOVA to evaluate the effects of the priming low dose radiation, of the high dose radiation, and of any interaction between the priming low and high doses of radiation. Bone histomorphometry was performed in the cancellous bone (aka trabecular bone) compartments of the proximal tibial metaphysis and of LV2. RESULTS: Cellular Response @ 3 Days The priming Low Dose radiation decreased osteoblast-covered bone perimeter in the proximal tibia and the total cell density in the bone marrow in the LV2. High Dose radiation, regardless of prior exposure to priming dose, dramatically reduced total cell density in bone marrow of both the long bone and vertebra. However, in the proximal tibia, High Dose radiation increased the osteoclast-covered bone perimeters, the density of adipocytes in bone marrow, and the area of bone marrow occupied by fat cells -- while in the LV2, adipocytes were rare and not stimulated by High Dose radiation. In an unexpected response, High Dose radiation dramatically increased (10-fold) osteoblast-covered bone perimeter in the LV2.
Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells
Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke
2015-01-01
Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487
DOE Office of Scientific and Technical Information (OSTI.GOV)
Healy, W.L.; Lo, T.C.; Covall, D.J.
1990-12-01
Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less
Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C
2016-10-10
The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.
Pusuwan, Pawana; Tuntawiroon, Malulee; Sritongkul, Nopamol; Chaudakshetrin, Pachee; Nopmaneejumruslers, Cherdchai; Komoltri, Chulalak; Thepamongkhol, Kullathorn; Khiewvan, Benjapa; Tuchinda, Pongpija; Sriussadaporn, Sutin
2011-03-01
To compare the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in patients with hyperthyroidism. One hundred fifty patients with proven hyperthyroidism were randomly allocated into the high (74 patients) and low (76 patients) dose regimen of I-131 treatment. Four patients of the high dose group and one patient of the low dose group were excluded because of lost follow-up. A gland-specific dosage was calculated on the estimated weight of thyroid gland and 24-hour I-131 uptake. The high and low I-131 dose regimens were 150 microCi/gm and 100 microCi/gm, respectively. The first mean radioiodine activity administered to the high and low dose group was 10.2 and 8 mCi, respectively. Repeated treatment was given to 25 patients of the high dose group and 40 patients of the low dose group. Clinical outcome and calculated costs for outpatient attendances, and laboratory tests together with initial and subsequent treatments were evaluated for one year after I-131 treatment. Elimination of hyperthyroidism that resulted in either euthyroidism or hypothyroidism was classified as therapeutic success. The cost effectiveness was also compared. At 6 months after treatment, 45 (64.3%) patients receiving high dose and 59 (78.7%) patients receiving low dose were hyperthyroidism. Clinical outcome at one year showed persistence of hyperthyroidism in 21 (30%) patients of the high dose regimen and 36 (48%) patients of the low dose regimen. At one year post treatment, it was demonstrated that the high dose regimen could eliminate hyperthyroidism in a significantly shorter time than the low dose regimen, i.e., 259.6 days and 305.5 days, respectively, p = 0.008). For the persistent hyperthyroid patients, the average total cost of treatment in the low dose group was significantly higher than that of the high dose group, i.e., 13,422.78 baht and 10,942.79 baht, respectively; p = 0.050). A high dose regimen of radioactive iodine treatment is more effective than the low dose regimen. The successful outcome of a high dose regimen occurred significantly earlier than that of the low dose regimen. For the persistent hyperthyroid patients, the average total cost in the low dose group was significantly higher than that of the high dose group.
Schild, Steven E; Fan, Wen; Stinchcombe, Thomas E; Vokes, Everett E; Ramalingam, Suresh S; Bradley, Jeffrey D; Kelly, Karen; Pang, Herbert H; Wang, Xiaofei
2018-04-21
Concurrent chemoradiotherapy(CRT) is standard therapy for locally-advanced non-small-cell lung cancer(LA-NSCLC)patients. This study was performed to examine thoracic radiotherapy(TRT) parameters and their impact on patient survival. We collected Individual patient data(IPD) from 3600LA-NSCLC patients participating in 16 cooperative group trials of concurrent CRT. The primary TRT parameters examined included field design strategy(elective nodal irradiation(ENI) compared to involved field TRT(IF-TRT)), total dose, and biologically effective dose(BED). Hazard ratios(HRs) for overall survival were calculated with univariable and multivariable Cox models. TRT doses ranged from 60 to 74 Gy with most treatments administered once-daily. ENI was associated with poorer survival than IF-TRT(univariable HR,1.37;95%CI,1.24-1.51,p<0.0001;multivariable HR,1.31;95%CI,1.08-1.59,p=0.002). The median survival of the IF and ENI patients were 24 and 16 months, respectively. Patients were divided into 3 dose groups: low total dose(60 Gy), medium total dose(>60Gy-66Gy) and high total dose(>66Gy-74 Gy). With reference to the low dose group, the multivariable HR's were 1.08 for the medium dose group(95%CI=0.93-1.25) and 1.12 for the high dose group(CI=0.97-1.30).The univariate p=0.054 and multivariable p=0.17. BED was grouped as follows: low(<55.5Gy 10 ), medium(=55.5 Gy 10) , or high(>55.5 Gy 10 ). With reference to the low BED group, the HR was 1.00(95%CI=0.85-1.18) for the medium BED group and 1.10(95%CI=0.93-1.31) for the high BED group. The univariable p=0.076 and multivariable p=0.16. For LA-NSCLC patients treated with concurrent CRT, IF-TRT was associated with significantly better survival than ENI-TRT. TRT total and BED dose levels were not significantly associated with patient survival. Future progress will require research focusing on better systemic therapy and TRT. Copyright © 2018. Published by Elsevier Inc.
Effect of amphetamine on human macronutrient intake.
Foltin, R W; Kelly, T H; Fischman, M W
1995-11-01
Six male subjects participated in a 15-day residential study examining the effects of amphetamine on macronutrient intake. During the first 11 days, carbohydrate intake was manipulated by providing lunch meals high (155 g) or low (25 g) in carbohydrate. Subjects received oral d-amphetamine (5, 10 mg/70 kg, BID) or placebo. Total daily caloric intake was similar under both lunch conditions (approximately 3400/Kcal), but carbohydrate contributed more energy under the high-carbohydrate condition. Both doses of amphetamine decreased total caloric intake to approximately 2600 Kcal, by decreasing the number of eating bouts, without affecting macronutrient selection. During the last four days subjects received a higher daily dose of amphetamine (30 mg/70 kg in four doses) or placebo, and were allowed to self-select lunch. Although 30 mg amphetamine decreased intake of all macronutrients, the relative contribution of carbohydrate to total caloric intake was increased from 54% to 62%, while the contribution of fat was decreased from 32% to 26% and the contribution of protein was decreased from 14% to 12%. Thus, at a high dose, amphetamine altered the relative contribution of specific macronutrients to total caloric intake.
Safety of an ED High-Dose Opioid Protocol for Sickle Cell Disease Pain.
Tanabe, Paula; Martinovich, Zoran; Buckley, Barbara; Schmelzer, Annie; Paice, Judith A
2015-05-01
A nurse-initiated high dose, opioid protocol for vaso-occlusive crisis (VOC) was implemented. Total intravenous morphine sulfate equivalents (IVMSE) in mgs] and safety was evaluated. A medical record review was conducted for all ED visits in adult patients with VOC post protocol implementation. Opioids doses and routes administered during the ED stay, and six hours into the hospital admission were abstracted and total IVMSE administered calculated. Oxygen saturation (SPO2), respiratory rate (RR), administration of naloxone or vasoactive medications, evidence of respiratory arrest, or any other types of resuscitation effort were abstracted. A RR of <10 or SPO2 <92% were coded as abnormal. Descriptive statistics report the total dose. Logistic regression was used to predict abnormal events. Predictors were age, gender, ED dose (10 mg increments) administered, and time from 1st dose to discharge from ED. 72 patients, 603 visits, 276 admitted. The total (ED & hospital dose) mean (95% CI) mg IVMSE administered for all visits was 93 mg (CI 86, 100), ED visit 63 mg (CI 59, 67) and hospital 66 mg (CI 59, 72). The mean (SD) time from administration of 1st analgesic dose to discharge from the ED was 203 (143) minutes, (range = 30-1396 minutes). During two visits, patients experienced a RR <10; while 61 visits were associated with a SPO2 <92%. No medications were administered, or resuscitative measures required. Controlling for demographics and evaluated at the average total ED dose, the longer patients were in the ED, patients were 1.359 times more likely to experience an abnormal vital sign. Controlling for demographics and evaluated at the average total time in the ED, for every 10 mg increase in IVMSE, patients were 1.057 times more likely to experience an abnormal vital sign. The effect of ED dose on the odds of experiencing an abnormal vital sign decreased by a multiplicative factor of 0.0970 for every 1 hour increase in time until discharge. The larger the dose administered in less time, the more likely patients experienced an abnormal vital sign. High opioid doses were safely administered to patients with sickle cell disease. Copyright © 2015 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.
Subchronic effects of methylmercury on plasma and organ biochemistries in great egret nestlings
Hoffman, D.J.; Spalding, M.G.; Frederick, P.C.
2005-01-01
In recent years, high concentrations of mercury have been found in wading birds in Florida, USA. Great egret (Ardea alba) chicks (2 weeks old) were dosed orally daily with the equivalent of 0, 0.5, or 5 ug/g Hg as methylmercury chloride in the diet for up to 12 weeks. Weakness of the legs or paralysis occurred in all high-dosed birds. Geometric mean blood Hg concentrations were 0.17, 10.3, and 78.5 ug/g (wet wt), respectively. Mercury concentrations for organs (ug/g wet wt), including brain (0.22, 3.4, and 35, respectively), liver (0.34, 15.1, 138, respectively), and kidney (0.28, 8.1, and 120, respectively), increased in a dose-dependent manner. Total glutathione (GSH) peroxidase activity was significantly lower in the plasma, brain, liver, and kidney of the high-dosed group. Plasma aspartate aminotransferase activity increased with mercury treatment, whereas lactate dehydrogenase activity decreased. Four other plasma chemistries were decreased significantly in the high-dosed group and included uric acid, total protein, albumin, and inorganic phosphorus. Lipid peroxidation increased in liver (low and high dose) and brain (high dose). Tissue changes in concentrations of reduced thiols included decreased total thiols and protein-bound thiols in liver, decreased protein-bound thiols in kidney, and increased GSH in kidney and brain. Activities of GSH S-transferase and oxidized glutathione reductase increased in liver. In kidney, GSH S-transferase and glucose-6-phosphate dehydrogenase activities increased with mercury dose. These findings, including apparent compensatory changes, are compared to other Hg studies where oxidative stress was reported in egrets, herons, and diving ducks in the field and mallards in the laboratory.
Joint minimization of uplink and downlink whole-body exposure dose in indoor wireless networks.
Plets, D; Joseph, W; Vanhecke, K; Vermeeren, G; Wiart, J; Aerts, S; Varsier, N; Martens, L
2015-01-01
The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism.
Joint Minimization of Uplink and Downlink Whole-Body Exposure Dose in Indoor Wireless Networks
Plets, D.; Joseph, W.; Vanhecke, K.; Vermeeren, G.; Wiart, J.; Aerts, S.; Varsier, N.; Martens, L.
2015-01-01
The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism. PMID:25793213
Zara, Janette N; Siu, Ronald K; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M; Ting, Kang; Soo, Chia
2011-05-01
The major Food and Drug Association-approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL.
Zara, Janette N.; Siu, Ronald K.; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M.; Ting, Kang
2011-01-01
The major Food and Drug Association–approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL. PMID:21247344
Chinese Data of Efficacy of Low- and High-Dose Iodine-131 for the Ablation of Thyroid Remnant.
Ma, Chao; Feng, Fang; Wang, Shaoyan; Fu, Hongliang; Wu, Shuqi; Ye, Zhiyi; Chen, Suyun; Wang, Hui
2017-06-01
Chinese data on the efficacy of low- and high-dose radioiodine for thyroid remnant are still absent. The aim of the study was to investigate whether a low dose of radioiodine is as effective as a high dose for remnant ablation in Chinese patients. Patients presenting for radioiodine ablation in the authors' department were included. Inclusion criteria were aged ≥16 years, total or near-total thyroidectomy, tumor-node-metastasis (TNM) stage of pT1-3, any N stage, and M0. All patients were randomly allocated to either the high-dose group of 3700 MBq or the low-dose group of 1850 MBq for remnant ablation. The response to treatment was defined as successful or unsuccessful after a six- to nine-month interval. Ablation was considered to be successful if patients fulfilled the following criteria: no tracer uptake in the thyroid bed on diagnosis whole-body scanning and a negative level of serum thyroglobulin. There were 327 patients enrolled between January 2013 and December 2014. More than 95% had papillary thyroid cancer. Data could be analyzed for 278 cases (M age = 44 years; 71.6% women), 155 in the low-dose group and 123 in the high-dose group. The rate of initial successful ablation was 84.2% in all patients, 82.6% in the low-dose group, and 86.2% in the high-dose group. There was no difference between the two groups (p = 0.509). In Chinese patients with differentiated thyroid carcinoma, the low dose of 1850 MBq radioiodine activity is as effective as a high dose of 3700 MBq for thyroid remnant ablation.
Comparative trial of low- and high-dose zonisamide as monotherapy for childhood epilepsy.
Eun, So-Hee; Kim, Heung Dong; Eun, Baik-Lin; Lee, In Kyu; Chung, Hee Jung; Kim, Joon Sik; Kang, Hoon-Chul; Lee, Young-Mock; Suh, Eun Sook; Kim, Dong Wook; Eom, Soyong; Lee, Joon Soo; Moon, Han Ku
2011-09-01
To evaluate the effectiveness of zonisamide (ZNS) as monotherapy in children with newly diagnosed epilepsy. This randomized, multicenter trial included a 2-4-week titration and a 24-week maintenance phase after randomization to low-(3-4 mg/kg/day) or high-(6-8 mg/kg/day) dose groups as target maintenance dosages. The primary outcome measure was the seizure-free rate over 6 months, while a secondary measure was the change in cognition and behavior from screening to the end of the maintenance phase. Out of 125 patients enrolled, 90 (49 low-dose and 41 high-dose) completed the study. Forty-one patients (63.1%) in the low-dose group and 34(57.6%) in the high-dose group achieved 6 months' freedom from seizures (p=0.66). After treatment, the picture arrangement subtest improved in the low-dose group (p=0.047) while the vocabulary subtest worsened in the high-dose group (p=0.020). Comparing between the two groups, the vocabulary subtest in the high-dose group was significantly worse than that in the low-dose group (p=0.002). Social competence, somatic complaints, depression/anxiety and delinquent and aggressive behavior in the low-dose group were significantly improved (p<0.05). Moreover, total social competence, somatic complaints, delinquent behavior, externalizing, and total behavior problems were significantly more improved in the low-dose group than the high-dose group (p<0.05). ZNS is an effective monotherapy for newly diagnosed childhood epilepsy. Lower doses of ZNS have a similar efficacy and more beneficial neurocognitive effects compared to higher doses. When prescribing higher doses of ZNS, one must be aware of the possible manifestation of problems associated with language development, such as those affecting vocabulary acquisition. Copyright © 2011 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
High-dose ascorbic acid decreases cholesterolemic factors of an atherogenic diet in guinea pigs.
Filis, Konstantinos; Anastassopoulou, Aikaterini; Sigala, Fragiska; Theodorou, Dimitrios; Manouras, Andreas; Leandros, Emanouel; Sigalas, Panagiotis; Hepp, Wolfgang; Bramis, John
2007-03-01
The study evaluates the effect of a high supplemental dose of ascorbic acid (AA) on plasma concentrations of total cholesterol (TC), triglycerides (TG), total lipids (TL), and lipoprotein fractions high-density, very-low-density-, and low-density lipoprotein (HDL, VLDL, LDL) in guinea pigs fed with atherogenic diet. Group I consisted of 5 normally fed guinea pigs plus a low dose of AA (1 mg/100 g/day), group II consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a low dose of AA (1 mg/100 g/day), and group III consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a high dose of AA (30 mg/100 g/day). Cholesterolemic factors concentrations were determined after nine weeks. Concentrations of TC, TG, TL, LDL, and VLDL were increased in group II compared to group I (p < 0.01 for all differences). Supplementation with a high dose of AA resulted in decreased concentrations of TC (p < 0.01), TG (p < 0.01), TL (p < 0.01), and LDL (p < 0.01) in group III compared to group II. Additionally, concentration of HDL was increased in group III compared to group II (p < 0.01). High-dose AA supplementation to an atherogenic diet decreases concentrations of TC, TG, TL, and LDL and increases concentration of HDL compared to low-dose AA.
Cummings, Timothy S; Guralnik, Mario; Rosenbloom, Richard A; Petteruti, Michael P; Digian, Kelly; Lefante, Carolyn
2007-01-01
The current study assessed the safety, tolerability, and palatability of the experimental drug QR-441(a) using three dose formulations and three routes of administration. A 4-day study was carried out using a total of 132 chickens. A total of 11 groups were formed (12 chickens per group) subjected to varying concentrations and routes of administration of QR-441(a). Chickens were given a high, medium, or low dose of QR-441(a) in either feed, water, or both for a period of 4 days. In addition, one group was dosed intranasally, one drop per nostril four times a day. Although no lesions were found to suggest toxicity or irritability, the medium- and high-dose water groups reduced their water intake. This reduction in water intake suggests that chickens may find the medium and high water doses unpalatable. There was no reduction in water intake in the low-dose water groups or in any of the formulated feed groups. There was also no evidence of toxicity or irritability in the nasal-dose group. These data support the use of the low, medium, and high doses in feed and the use of the low-dose concentration in water for the administration of QR-441(a). The data also suggest that QR-441(a) can be administered intranasally without the presence of any adverse events.
High dose psilocybin is associated with positive subjective effects in healthy volunteers.
Nicholas, Christopher R; Henriquez, Kelsey M; Gassman, Michele C; Cooper, Karen M; Muller, Daniel; Hetzel, Scott; Brown, Randall T; Cozzi, Nicholas V; Thomas, Chantelle; Hutson, Paul R
2018-06-01
The aim of the current study was to investigate the relationship between escalating higher doses of psilocybin and the potential psilocybin occasioned positive subjective effects. Healthy participants ( n=12) were given three escalating doses of oral psilocybin (0.3 mg/kg; 0.45 mg/kg; 0.6 mg/kg) or (18.8-36.6 mg; 27.1-54.0 mg; 36.3-59.2 mg) a minimum of four weeks apart in a supervised setting. Blood and urine samples, vital signs, and electrocardiograms were obtained. Subjective effects were assessed using the Mystical Experience Questionnaire and Persisting Effects Questionnaire. There was a significant linear dose-related response in Mystical Experience Questionnaire total score and the transcendence of time and space subscale, but not in the rate of a complete mystical experience. There was also a significant difference between dose 3 compared to dose 1 on the transcendence of time and space subscale, while no dose-related differences were found for Mystical Experience Questionnaire total scores or rate of a mystical experience. Persisting Effects Questionnaire positive composite scores 30 days after completion of the last dose were significantly higher than negative composite scores. Persisting Effects Questionnaire results revealed a moderate increase in sense of well-being or life satisfaction on average that was associated with the maximum Mystical Experience Questionnaire total score. Pharmacokinetic measures were associated with dose but not with Mystical Experience Questionnaire total scores or rate of a mystical experience. High doses of psilocybin elicited subjective effects at least as strong as the lower doses and resulted in positive persisting subjective effects 30 days after, indicating that a complete mystical experience was not a prerequisite for positive outcomes.
McLain, Michael Lee; Sheridan, Timothy J.; Hjalmarson, Harold Paul; ...
2014-11-11
This paper investigates the effects of high dose rate ionizing radiation and total ionizing dose (TID) on tantalum oxide (TaO x) memristors. Transient data were obtained during the pulsed exposures for dose rates ranging from approximately 5.0 ×10 7 rad(Si)/s to 4.7 ×10 8 rad(Si)/s and for pulse widths ranging from 50 ns to 50 μs. The cumulative dose in these tests did not appear to impact the observed dose rate response. Static dose rate upset tests were also performed at a dose rate of ~3.0 ×10 8 rad(Si)/s. This is the first dose rate study on any type ofmore » memristive memory technology. In addition to assessing the tolerance of TaO x memristors to high dose rate ionizing radiation, we also evaluated their susceptibility to TID. The data indicate that it is possible for the devices to switch from a high resistance off-state to a low resistance on-state in both dose rate and TID environments. The observed radiation-induced switching is dependent on the irradiation conditions and bias configuration. Furthermore, the dose rate or ionizing dose level at which a device switches resistance states varies from device to device; the enhanced susceptibility observed in some devices is still under investigation. As a result, numerical simulations are used to qualitatively capture the observed transient radiation response and provide insight into the physics of the induced current/voltages.« less
NASA Astrophysics Data System (ADS)
Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.
2012-04-01
While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4) The clinically acceptable lowest imaging dose level is task dependent. In our study, 72.8 mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.
Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas.
Farzin, Mostafa; Molls, Michael; Astner, Sabrina; Rondak, Ina-Christine; Oechsner, Markus
2015-12-01
In 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (VMAT): simultaneous integrated boost (SIB) vs. sequential boost (SEB). The investigation focused on the analysis of dose distributions in the target volumes and the organs at risk (OARs). After contouring the target volumes [planning target volumes (PTVs) and boost volumes (BVs)] and OARs, SIB planning and SEB planning were performed. The SEB method consisted of two plans: in the first plan the PTV received 50 Gy in 25 fractions with a 2-Gy dose per fraction. In the second plan the BV received 10 Gy in 5 fractions with a dose per fraction of 2 Gy. The doses of both plans were summed up to show the total doses delivered. In the SIB method the PTV received 54 Gy in 30 fractions with a dose per fraction of 1.8 Gy, while the BV received 60 Gy in the same fraction number but with a dose per fraction of 2 Gy. All of the OARs showed higher doses (Dmax and Dmean) in the SEB method when compared with the SIB technique. The differences between the two methods were statistically significant in almost all of the OARs. Analysing the total doses of the target volumes we found dose distributions with similar homogeneities and comparable total doses. Our analysis shows that the SIB method offers advantages over the SEB method in terms of sparing OARs.
Population dose commitments due to radioactive releases from nuclear-power-plant sites in 1978
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peloquin, R.A.; Schwab, J.D.; Baker, D.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1978. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 200 person-rem to a low of 0.0004 person-rem with an arithmetic mean of 14 person-rem. The total population dose for allsites was estimated at 660 person-rem for the 93 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 3 x 10/sup -6/ mrem to a high of 0.08 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
Population dose commitments due to radioactive releases from Nuclear-Power-Plant Sites in 1979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.; Peloquin, R.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1979. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 1300 person-rem to a low of 0.0002 person-rem with an arithmetic mean of 38 person-rem. The total population dose for all sites was estimated at 1800 person-rem for the 94 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 2 x 10/sup -6/ mrem to a high of 0.7 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
Population Dose Commitments Due to Radioactive Releases from Nuclear Power Plant Sites in 1977
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D. A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1977. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ, Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving variousmore » average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 220 person-rem to a low of 0.003 person-rem with an arithmetic mean of 16 person-rem. The total population dose for all sites was estimated at 700 person-rem for the 92 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 2 x 10{sup -5} mrem to a high of 0.1 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
Boufouss, El Hafed; Francis, Laurent A; Kilchytska, Valeriya; Gérard, Pierre; Simon, Pascal; Flandre, Denis
2013-12-13
This paper presents an ultra-low power CMOS voltage reference circuit which is robust under biomedical extreme conditions, such as high temperature and high total ionized dose (TID) radiation. To achieve such performances, the voltage reference is designed in a suitable 130 nm Silicon-on-Insulator (SOI) industrial technology and is optimized to work in the subthreshold regime of the transistors. The design simulations have been performed over the temperature range of -40-200 °C and for different process corners. Robustness to radiation was simulated using custom model parameters including TID effects, such as mobilities and threshold voltages degradation. The proposed circuit has been tested up to high total radiation dose, i.e., 1 Mrad (Si) performed at three different temperatures (room temperature, 100 °C and 200 °C). The maximum drift of the reference voltage V(REF) depends on the considered temperature and on radiation dose; however, it remains lower than 10% of the mean value of 1.5 V. The typical power dissipation at 2.5 V supply voltage is about 20 μW at room temperature and only 75 μW at a high temperature of 200 °C. To understand the effects caused by the combination of high total ionizing dose and temperature on such voltage reference, the threshold voltages of the used SOI MOSFETs were extracted under different conditions. The evolution of V(REF) and power consumption with temperature and radiation dose can then be explained in terms of the different balance between fixed oxide charge and interface states build-up. The total occupied area including pad-ring is less than 0.09 mm2.
NASA Technical Reports Server (NTRS)
Campola, Michael; Wyrwas, Edward
2017-01-01
The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.
NAKANO, KENJI; SATO, YASUYOSHI; TOSHIYASU, TAKASHI; SATO, YUKIKO; INAGAKI, LINA; TOMOMATSU, JUNICHI; SASAKI, TORU; SHIMBASHI, WATARU; FUKUSHIMA, HIROFUMI; YONEKAWA, HIROYUKI; MITANI, HIROKI; KAWABATA, KAZUYOSHI; TAKAHASHI, SHUNJI
2016-01-01
Although high-dose cisplatin is the standard regimen of concurrent chemoradiotherapy (CCRT) for locally advanced head and neck squamous cell carcinoma (HNSCC), varying levels of patient tolerance towards cisplatin have been reported, and the predictive factors of cisplatin tolerance remain to be elucidated. The present study retrospectively reviewed newly diagnosed HNSCC patients who received CCRT. Cisplatin (80 mg/m2) was administered every 3 weeks. The proportion of high-dose cisplatin-tolerant patients (cumulative cisplatin dose, ≥200 mg/m2) was determined, and the predictive factors of cisplatin tolerance were analyzed in a logistic regression analysis. Between June 2006 and March 2013, a total of 159 patients were treated with CCRT. The median follow-up time was 36.7 months. A total of 73 patients (46%) tolerated a cumulative cisplatin dose ≥200 mg/m2; male gender [odds ratio (OR), 25.00; P=0.005] and high body surface area (BSA) (>1.80 m2; OR, 2.21; P=0.032) were significantly predictive of high-dose cisplatin tolerance. The high-dose cisplatin-tolerant patients had a significantly higher complete response (CR) rate (82 vs. 67%, P=0.045); however, there were no significant between-group differences in the 3-year OS (79.5 vs. 81.2%, P=0.59) or PFS (70.4 vs. 44.6%, P=0.076) by cisplatin tolerance. In clinical practice, approximately one-half of the patients tolerated high-dose cisplatin in CCRT. Male gender and high BSA could be predictive of cisplatin tolerance. PMID:26893880
Effects of ionizing radiation on charge-coupled imagers
NASA Technical Reports Server (NTRS)
Killiany, J. M.; Baker, W. D.; Saks, N. S.; Barbe, D. F.
1975-01-01
The effects of ionizing radiation on three different charge coupled imagers have been investigated. Device performance was evaluated as a function of total gamma ray dose. The principal failure mechanisms have been identified for each particular device structure. The clock and bias voltages required for high total dose operation of the devices are presented.
Jethava, Y; Mitchell, A; Zangari, M; Waheed, S; Schinke, C; Thanendrarajan, S; Sawyer, J; Alapat, D; Tian, E; Stein, C; Khan, R; Heuck, C J; Petty, N; Avery, D; Steward, D; Smith, R; Bailey, C; Epstein, J; Yaccoby, S; Hoering, A; Crowley, J; Morgan, G; Barlogie, B; van Rhee, F
2016-07-29
Multiple myeloma (MM) is a heterogeneous disease with high-risk patients progressing rapidly despite treatment. Various definitions of high-risk MM are used and we reported that gene expression profile (GEP)-defined high risk was a major predictor of relapse. In spite of our best efforts, the majority of GEP70 high-risk patients relapse and we have noted higher relapse rates during drug-free intervals. This prompted us to explore the concept of less intense drug dosing with shorter intervals between courses with the aim of preventing inter-course relapse. Here we report the outcome of the Total Therapy 5 trial, where this concept was tested. This regimen effectively reduced early mortality and relapse but failed to improve progression-free survival and overall survival due to relapse early during maintenance.
Dose-dependent effects of vitamin 1,25(OH)2D3 on oxidative stress and apoptosis.
Cakici, Cagri; Yigitbasi, Turkan; Ayla, Sule; Karimkhani, Hadi; Bayramoglu, Feyza; Yigit, Pakize; Kilic, Ertugrul; Emekli, Nesrin
2018-02-08
Background The purpose of this study is to examine the dose-dependent effects of vitamin 1,25(OH)2D3 on apoptosis and oxidative stress. Methods In this study, 50 male Balb/c mice were used as control and experiment groups. The mice were divided into 5 groups each consisting of 10 mice. Calcitriol was intraperitoneally administered as low dose, medium dose, medium-high dose and high dose vitamin D groups (at 0.5, 1, 5 and 10 μg/kg, respectively), for three times a week during 14 days. At the end of the study, annexin V was measured by enzyme-linked immunosorbent assay method, and total antioxidant capacity and total oxidant status values were measured by colorimetric method in serum. Hematoxylin eosin staining was performed in liver tissues and periodic acid schiff staining was performed in kidney tissues. Results While comparing the results of medium-high dose (5 μg/kg) and high dose (10 μg/kg) vitamin D administration to that of the control group, it was observed that serum antioxidant status and annexin V levels decreased and glomerular mesenchial matrix ratio increased in kidney (p<0.05). In addition to these findings, in the group receiving high dose vitamin D (10 μg/kg), it was observed that the damage to the liver increased together with the the oxidative stress index values (p<0.05). Conclusions As a result, this study was the first in the literature to report that use of high-dose vitamin D (10 μg/kg) results in oxidant effect, rather than being an antioxidant, and causes severe histopathological toxicity in the liver and kidney.
Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.
Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N
2016-04-01
Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.
Diagnostic radiation exposure in pediatric trauma patients.
Brunetti, Marissa A; Mahesh, Mahadevappa; Nabaweesi, Rosemary; Locke, Paul; Ziegfeld, Susan; Brown, Robert
2011-02-01
The amount of imaging studies performed for disease diagnosis has been rapidly increasing. We examined the amount of radiation exposure that pediatric trauma patients receive because they are an at-risk population. Our hypothesis was that pediatric trauma patients are exposed to high levels of radiation during a single hospital visit. Retrospective review of children who presented to Johns Hopkins Pediatric Trauma Center from July 1, 2004, to June 30, 2005. Radiographic studies were recorded for each patient and doses were calculated to give a total effective dose of radiation. All radiographic studies that each child received during evaluation, including any associated hospital admission, were included. A total of 945 children were evaluated during the study year. A total of 719 children were included in the analysis. Mean age was 7.8 (±4.6) years. Four thousand six hundred three radiographic studies were performed; 1,457 were computed tomography (CT) studies (31.7%). Average radiation dose was 12.8 (±12) mSv. We found that while CT accounted for only 31.7% of the radiologic studies performed, it accounted for 91% of the total radiation dose. Mean dose for admitted children was 17.9 (±13.8) mSv. Mean dose for discharged children was 8.4 (±7.8) mSv (p<0.0001). Burn injuries had the lowest radiation dose [1.2 (±2.6) mSv], whereas motor vehicle collision victims had the highest dose [18.8 (±14.7) mSv]. When the use of radiologic imaging is considered essential, cumulative radiation exposure can be high. In young children with relatively long life spans, the benefit of each imaging study and the cumulative radiation dose should be weighed against the long-term risks of increased exposure.
Dose-Response Analysis of RNA-Seq Profiles in Archival ...
Use of archival resources has been limited to date by inconsistent methods for genomic profiling of degraded RNA from formalin-fixed paraffin-embedded (FFPE) samples. RNA-sequencing offers a promising way to address this problem. Here we evaluated transcriptomic dose responses using RNA-sequencing in paired FFPE and frozen (FROZ) samples from two archival studies in mice, one 20 years old. Experimental treatments included 3 different doses of di(2-ethylhexyl)phthalate or dichloroacetic acid for the recently archived and older studies, respectively. Total RNA was ribo-depleted and sequenced using the Illumina HiSeq platform. In the recently archived study, FFPE samples had 35% lower total counts compared to FROZ samples but high concordance in fold-change values of differentially expressed genes (DEGs) (r2 = 0.99), highly enriched pathways (90% overlap with FROZ), and benchmark dose estimates for preselected target genes (2% difference vs FROZ). In contrast, older FFPE samples had markedly lower total counts (3% of FROZ) and poor concordance in global DEGs and pathways. However, counts from FFPE and FROZ samples still positively correlated (r2 = 0.84 across all transcripts) and showed comparable dose responses for more highly expressed target genes. These findings highlight potential applications and issues in using RNA-sequencing data from FFPE samples. Recently archived FFPE samples were highly similar to FROZ samples in sequencing q
Strategies for systemic radiotherapy of micrometastases using antibody-targeted 131I.
Wheldon, T E; O'Donoghue, J A; Hilditch, T E; Barrett, A
1988-02-01
A simple analysis is developed to evaluate the likely effectiveness of treatment of micrometastases by antibody-targeted 131I. Account is taken of the low levels of tumour uptake of antibody-conjugated 131I presently achievable and of the "energy wastage" in targeting microscopic tumours with a radionuclide whose disintegration energy is widely dissipated. The analysis shows that only modest doses can be delivered to micrometastases when total body dose is restricted to levels which allow recovery of bone marrow. Much higher doses could be delivered to micrometastases when bone marrow rescue is used. A rationale is presented for targeted systemic radiotherapy used in combination with external beam total body irradiation (TBI) and bone marrow rescue. This has some practical advantages. The effect of the targeted component is to impose a biological non-uniformity on the total body dose distribution with regions of high tumour cell density receiving higher doses. Where targeting results in high doses to particular normal organs (e.g. liver, kidney) the total dose to these organs could be kept within tolerable limits by appropriate shielding of the external beam radiation component of the treatment. Greater levels of tumour cell kill should be achievable by the combination regime without any increase in normal tissue damage over that inflicted by conventional TBI. The predicted superiority of the combination regime is especially marked for tumours just below the threshold for detectability (e.g. approximately 1 mm-1 cm diameter). This approach has the advantage that targeted radiotherapy provides only a proportion of the total body dose, most of which is given by a familiar technique. The proportion of dose given by the targeted component could be increased as experience is gained. The predicted superiority of the combination strategy should be experimentally testable using laboratory animals. Clinical applications should be cautiously approached, with due regard to the limitations of the theoretical analysis.
[Protection and bidirectional effect of rhubarb anthraquinone and tannins for rats' liver].
Qin, Lu-shan; Zhao, Hai-ping; Zhao, Yan-ling; Ma, Zhi-jiel; Zeng, Ling-na; Zhang, Ya-ming; Zhang, Ping; Yan, Dan; Bai, Zhao-fang; Li, Yue; Hao, Qing-xiu; Zhao, Kui-jun; Wang, Jia-bo; Xiao, Xiao-he
2014-06-01
To compare the bidirectional effect of rhubarb total anthraquinone (TA) and total tannins (TT) on rats' liver. One hundred rats were randomly divided into 10 groups, i.e., the blank group, the model group, the blank + high dose TA group, the blank +low dose TA group, the blank + high dose TT group, the blank + low dose TT group, the model + high dose TA group, the model + low dose TA group, the model +high dose TT group, and the model + low dose TT group, 10 in each group. The carbon tetrachloride (CCI4) was used to prepare the acute liver injury rat model. TA and TT of rhubarb (at 5.40 g crude drugs/kg and 14.69 g crude drugs/kg) were intragastrically administrated to rats in all groups except the blank group and the model group, once daily for 6 successive days.The general state of rats, biochemical indices such as alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), laminin (LN), hyaluronic acid (HA), transforming growth factor beta1 (TGF-beta1), as well pathological results of rat liver tissues. Finally the protection laws of TA and TT for rats' liver were analyzed using factor analysis. Compared with the blank control group, all biochemical indices increased in the blank group (P < 0.05, P < 0.01). HA also increased in the blank + high dose TA group; AST, ALT, and HA also increased in the blank +high dose TT group (P < 0.05). Compared with the model group, AST, ALT, ALP, HA, and TGF-beta1 significantly decreased in the model + low dose TA group, the model + high dose TA group, the model + low dose TT group (P < 0.05, P < 0.01). Serum AST, ALT, and ALP also decreased in the model + high dose TT group (P < 0.05, P < 0.01). Pathological results showed that mild swollen liver cells in the model + high dose TA group. Fatty degeneration and fragmental necrosis around the central veins occurred in the blank + high dose TA group. The pathological injury was inproved in the model +low dose TA group. Two common factors, liver fibrosis and liver cell injury, were extracted by using factor analysis. TA showed stronger improvement of the two common factors than TT. Rhubarb TA and TT showed protective and harmful effects on rats' liver. At an equivalent dosage, TA had better liver protection than TT. High dose TT played a role in liver injury to some extent.
The radiation dosimeter on-board the FY-4 Satellite
NASA Astrophysics Data System (ADS)
Zhang, B.; Sun, Y.; Zhang, S.; Zhang, X.; Sun, Y.; Jing, T.
2017-12-01
The total radiation dose effect can lead to a decrease in the performance of satellite devices or materials. Accurately obtaining the total radiation dose during satellite operation could help to analyze the abnormality of payloads in orbit and optimize the design of radiation shielding. The radiation dosimeter is one of the space environmental monitoring devices on the "FY-4" satellite, which is a new generation of geostationary meteorological satellite. The dosimeter consists of 8 detectors, which are installed in different locations of the satellite, to obtain the total radiation dose with different shielding thickness and different orientations. To measure a total radiation dose up to 2000krad(Si), 100nm ion implantation RADFET was used. To improve the sensitivity of the dosimeter, the bias voltage of RADFET is set to 15V, and a 10V, 15-bit A/D is adopted to digitalize the RADFET's threshold voltage, which is increased as the total radiation dose grows. In addition, the temperature effect of RADFET is corrected from the measured temperature on orbit. The preliminary monitoring results show that the radiation dose is less than 35rad (Si) per day at 0.87 mm shielding thickness of equivalent aluminum in the geostationary orbit, and the dose in Y direction of the satellite is less than those in the X and Z directions. The radiation dose at the thickness of 3.87 mm equivalent aluminum is less than 1rad(Si)/day. It is found that the daily total dose measured by the dosimeter has a strong correlation with the flux of high energy electrons.
Population dose commitments due to radioactive releases from nuclear power plant sites in 1985
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commericial power reactors operating during 1985. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 61 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 73 person-rem to a low of 0.011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 200 person-rem for the 110 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 5 /times/ 10/sup /minus/6/ mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
Population dose commitments due to radioactive releases from nuclear power plant sites in 1984
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1984. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 56 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 110 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 5 person-rem. The total population dose for all sites was estimated at 280 person-rem for the 100 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 6 x 10/sup -6/ mrem to a high of 0.04 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
Population dose commitments due to radioactive releases from nuclear power plant sites in 1986
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1986. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 66 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 kmmore » around each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 31 person-rem to a low of 0.0007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.7 person-rem. The total population dose for all sites was estimated at 110 person-rem for the 140 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 2 {times} 10{sup -6} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. 12 refs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.; Peloquin, R.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1982. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 51 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each sitemore » receiving various average dose commitments from the airborne pathways. The total dose commitments from both liquid and airborne pathways ranged from a high of 30 person-rem to a low of 0.007 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 130 person-rem for the 100 million people considered at risk. The average individual dose commitment from all pathways on a site basis ranged from a low of 6 x 10/sup -7/ mrem to a high of 0.06 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites.« less
NASA Astrophysics Data System (ADS)
Čížková, Klára; Láska, Kamil; Metelka, Ladislav; Staněk, Martin
2018-02-01
This paper evaluates the variability of erythemal ultraviolet (EUV) radiation from Hradec Králové (Czech Republic) in the period 1964-2013. The EUV radiation time series was reconstructed using a radiative transfer model and additional empirical relationships, with the final root mean square error of 9.9 %. The reconstructed time series documented the increase in EUV radiation doses in the 1980s and the 1990s (up to 15 % per decade), which was linked to the steep decline in total ozone (10 % per decade). The changes in cloud cover were the major factor affecting the EUV radiation doses especially in the 1960s, 1970s, and at the beginning of the new millennium. The mean annual EUV radiation doses in the decade 2004-2013 declined by 5 %. The factors affecting the EUV radiation doses differed also according to the chosen integration period (daily, monthly, and annually): solar zenith angle was the most important for daily doses, cloud cover, and surface UV albedo for their monthly means, and the annual means of EUV radiation doses were most influenced by total ozone column. The number of days with very high EUV radiation doses increased by 22 % per decade, the increase was statistically significant in all seasons except autumn. The occurrence of the days with very high EUV doses was influenced mostly by low total ozone column (82 % of days), clear-sky or partly cloudy conditions (74 % of days) and by increased surface albedo (19 % of days). The principal component analysis documented that the occurrence of days with very high EUV radiation doses was much affected by the positive phase of North Atlantic Oscillation with an Azores High promontory reaching over central Europe. In the stratosphere, a strong Arctic circumpolar vortex and the meridional inflow of ozone-poor air from the southwest were favorable for the occurrence of days with very high EUV radiation doses. This is the first analysis of the relationship between the high EUV radiation doses and macroscale circulation patterns, and therefore more attention should be given also to other dynamical variables that may affect the solar UV radiation on the Earth surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deeg, H.J.; Storb, R.; Weiden, P.L.
1981-11-01
Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs diedmore » from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors.« less
NASA Astrophysics Data System (ADS)
Jha, Pradeep K.; Jha, Rakhi; Gupta, B. L.; Guha, Sujoy K.
2010-05-01
Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG ® (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG ®. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.
Hodgson, Sam; Larvin, Joseph T; Dearman, Charles
2015-09-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: what dose of tranexamic acid is most effective and safe for adult patients undergoing cardiac surgery? Altogether 586 papers were found using the reported search, of which 12 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Current evidence shows clinical benefit of using high-dose tranexamic acid (>80 mg/kg total dose) as opposed to low-dose tranexamic acid (<50 mg/kg total dose) in cardiac surgery with cardiopulmonary bypass. Evidence from a large randomized controlled trial shows that patients receiving high-dose tranexamic acid lose less blood postoperatively than patients receiving low-dose tranexamic acid (590 vs 820 ml, P = 0.01). Patients receiving high-dose tranexamic acid also require fewer units of blood product transfusion (2.5 units vs 4.1 units; P = 0.02) and are less likely to undergo repeat surgery to achieve haemostasis. This effect is larger in those who are at high risk of bleeding. Several prospective studies comparing doses found no difference in clinical outcomes between high- and low-dose regimens, but excluded patients at high risk of bleeding. However, data from numerous observational studies demonstrate that tranexamic acid use is associated with an increased risk of postoperative seizure; one analysis showed tranexamic acid use to be a very strong independent predictor (odds ratio = 14.3, P < 0.001). There is also evidence that this risk of seizure is dose-dependent, with the greatest risk at higher doses of tranexamic acid. We conclude that, in general, patients with a high risk of bleeding should receive high-dose tranexamic acid, while those at low risk of bleeding should receive low-dose tranexamic acid with consideration given to potential dose-related seizure risk. We recommend the regimens of high-dose (30 mg kg(-1) bolus + 16 mg kg(-1) h(-1) + 2 mg kg(-1) priming) and low-dose (10 mg kg(-1) bolus + 1 mg kg(-1) h(-1) + 1 mg kg(-1) priming) tranexamic acid, as these are well established in terms of safety profile and have the strongest evidence for efficacy. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Technical Reports Server (NTRS)
Gridley, Daila S.; Pecaut, Michael J.; Dutta-Roy, Radha; Nelson, Gregory A.
2002-01-01
The goal of part I of this study was to evaluate the effects of whole-body proton irradiation on lymphoid organs and specific leukocyte populations. C57BL/6 mice were exposed to the entry region of the proton Bragg curve to total doses of 0.5 gray (Gy), 1.5 Gy, and 3.0 Gy, each delivered at a low dose rate (LDR) of 1 cGy/min and high dose rate (HDR) of 80 cGy/min. Non-irradiated and 3 Gy HDR gamma-irradiated groups were included as controls. At 4 days post-irradiation, highly significant radiation dose-dependent reductions were observed in the mass of both lymphoid organs and the numbers of leukocytes and T (CD3(+)), T helper (CD3(+)/CD4(+)), T cytotoxic (CD3(+)/CD8(+)), and B (CD19(+)) cells in both blood and spleen. A less pronounced dose effect was noted for natural killer (NK1.1(+) NK) cells in spleen. Monocyte, but not granulocyte, counts in blood were highly dose-dependent. The numbers for each population generally tended to be lower with HDR than with LDR radiation; a significant dose rate effect was found in the percentages of T and B cells, monocytes, and granulocytes and in CD4(+):CD8(+) ratios. These data indicate that mononuclear cell response to the entry region of the proton Bragg curve is highly dependent upon the total dose and that dose rate effects are evident with some cell types. Results from gamma- and proton-irradiated groups (both at 3 Gy HDR) were similar, although proton-irradiation gave consistently lower values in some measurements.
Inhaled corticosteroids and asthma control in adult-onset asthma: 12-year follow-up study.
Vähätalo, Iida; Ilmarinen, Pinja; Tuomisto, Leena E; Niemelä, Onni; Kankaanranta, Hannu
2018-04-01
Prescribed inhaled corticosteroid (ICS) doses in asthma have been studied in cross-sectional settings whereas long-term follow-up studies have not been carried out. To evaluate prescribed medication longitudinally by calculating cumulative ICS doses and dose changes in a cohort of new-onset adult asthma during 12 years and in different groups of asthma control. A total of 203 patients were followed for 12 years as part of Seinäjoki Adult Asthma Study (SAAS). All asthma-related visits and prescribed medication over the study period were collected from medical records. Total cumulative ICS dose for the 12-year follow-up period was 3.4g (±SEM 0.1) per patient. Both respiratory specialists and GPs prescribed step-ups and step-downs in ICS treatment and in total 649 dose changes were noted during the follow-up (median 3(1-5) per patient). Patients with uncontrolled asthma received higher ICS doses throughout the follow-up period, and therefore, cumulative 12-year ICS dose (3.8g ± SEM 0.2) in this group was higher than that in those with partially controlled (3.4g ± SEM 0.2) or controlled disease (2.9g ± SEM 0.2) (p = 0.0001). Patients with uncontrolled asthma were also prescribed a higher number of ICS dose changes than patients with controlled disease. Despite frequent dose changes and high ICS doses during the 12-year follow-up, the level of asthma control remained poor in patients with uncontrolled asthma. This suggests that high ICS doses may not be effective enough for management of disease in patients with uncontrolled adult-onset asthma and novel targeted treatments are required. Copyright © 2018 Elsevier Ltd. All rights reserved.
Depth dose and off-axis characteristics of TLD in therapeutic pion beams.
Hogstrom, K R; Irifune, T
1980-07-01
The thermoluminescent (TL) response of LiF (TLD-100, TLD-600, TLD-700) and Li2B4O7 (TLD-800) has been measured as a function of depth and off-axis position in a therapeutic negative-pion beam in order to evaluate their usefulness in pion radiotherapy. TLD-100, TLD-600, and TLD-800 have been shown to be of little use as in vivo dosemeters because the neutron kerma relative to that in tissue changes grossly with depth. The neutron source comes primarily from pion absorption in the lead-alloy collimator. The 200 degrees C TLD-700 response agrees well with the depth dose spectra, except for small changes due to the varying linear energy transfer (LET) distributions. This variation can be partially accounted for by incorporating the known LET response of LiF. The 260 degrees C peak of TLD-700 has been found to be approximately four times more sensitive than the 200 degrees C peak to high LET dose. Using a simple model of the LET responses, the measured 200 degrees C and 260 degrees C peaks predict total dose within +/- 4% and high LET dose within +/- 50%, therefore indicating TLD-700 to be a good in vivo dosemeter for total dose but only an indicator of high LET dose.
Chen, I-Ju; Liu, Chia-Yu; Chiu, Jung-Peng; Hsu, Chung-Hua
2016-06-01
To examine the effect and safety of high-dose green tea extract (Epigallocatechin gallate, EGCG) at a daily dosage of 856.8 mg on weight reduction and changes of lipid profile and obesity-related hormone peptides in women with central obesity. We conducted a randomized, double-blind trial registered under ClinicalTrials.gov Identifier no. NCT02147041. A total of 115 women with central obesity were screened at our clinic. 102 of them with a body mass index (BMI) ≥ 27 kg/m(2) and a waist circumference (WC) ≥ 80 cm were eligible for the study. These women were randomly assigned to either a high-dose green tea group or placebo group. The total treatment time was 12 weeks. The main outcome measures were anthropometric measurements, lipid profiles, and obesity related hormone peptides including leptin, adiponectin, ghrelin, and insulin. Significant weight loss, from 76.8 ± 11.3 kg to 75.7 ± 11.5 kg (p = 0.025), as well as decreases in BMI (p = 0.018) and waist circumference (p = 0.023) were observed in the treatment group after 12 weeks of high-dose EGCG treatment. This study also demonstrated a consistent trend of decreased total cholesterol, reaching 5.33%, and decreased LDL plasma levels. There was good tolerance of the treatment among subjects without any side effects or adverse events. Significantly lower ghrelin levels and elevated adiponectin levels were detected in the study group than in the placebo group. 12 weeks of treatment with high-dose green tea extract resulted in significant weight loss, reduced waist circumference, and a consistent decrease in total cholesterol and LDL plasma levels without any side effects or adverse effects in women with central obesity. The antiobestic mechanism of high-dose green tea extract might be associated in part with ghrelin secretion inhibition, leading to increased adiponectin levels. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Effects of X-ray irradiation on the microbial growth and quality of flue-cured tobacco during aging
NASA Astrophysics Data System (ADS)
Wang, J. J.; Xu, Z. C.; Fan, J. L.; Wang, Y.; Tian, Z. J.; Chen, Y. T.
2015-06-01
X-ray irradiation was evaluated for improving microbial safety and the quality of flue-cured tobacco during aging. Tobacco samples were irradiated at doses of 0, 1, 2, 3 and 5 kGy and stored for 12 months under normal storage conditions or in a high-humidity (RH>70%) room. Microbiological data indicated that the population of total aerobic bacteria was significantly decreased with increasing irradiation doses. In particular, a dose of 2 kGy was effective for the decontamination of fungi from the tested samples, with a 0.93 log CFU/g reduction for bacteria. The control and 1 kGy X-ray treated tobacco samples were became rotted and moldy after the 12th month, whereas those treated with 2, 3 and 5 kGy had no detectable mold during 12 months of storage at high humidity. Chemical measurements showed that irradiation up to 3 kGy did not affect the total nitrogen, nicotine, reducing and total sugars, ratio of total nitrogen to nicotine and sugar-to-nicotine ratio. Furthermore, sensory evaluation results also showed that X-ray irradiation did not affect sensory scores with irradiation at a dose <3 kGy. Based on these results, X-ray irradiation dose in the range of 2-3 kGy is recommended for the decontamination of fungi from flue-cured tobacco.
High-speed large angle mammography tomosynthesis system
NASA Astrophysics Data System (ADS)
Eberhard, Jeffrey W.; Staudinger, Paul; Smolenski, Joe; Ding, Jason; Schmitz, Andrea; McCoy, Julie; Rumsey, Michael; Al-Khalidy, Abdulrahman; Ross, William; Landberg, Cynthia E.; Claus, Bernhard E. H.; Carson, Paul; Goodsitt, Mitchell; Chan, Heang-Ping; Roubidoux, Marilyn; Thomas, Jerry A.; Osland, Jacqueline
2006-03-01
A new mammography tomosynthesis prototype system that acquires 21 projection images over a 60 degree angular range in approximately 8 seconds has been developed and characterized. Fast imaging sequences are facilitated by a high power tube and generator for faster delivery of the x-ray exposure and a high speed detector read-out. An enhanced a-Si/CsI flat panel digital detector provides greater DQE at low exposure, enabling tomo image sequence acquisitions at total patient dose levels between 150% and 200% of the dose of a standard mammographic view. For clinical scenarios where a single MLO tomographic acquisition per breast may replace the standard CC and MLO views, total tomosynthesis breast dose is comparable to or below the dose in standard mammography. The system supports co-registered acquisition of x-ray tomosynthesis and 3-D ultrasound data sets by incorporating an ultrasound transducer scanning system that flips into position above the compression paddle for the ultrasound exam. Initial images acquired with the system are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viani, Gustavo Arruda; Stefano, Eduardo Jose; Afonso, Sergio Luis
2009-08-01
Purpose: To determine in a meta-analysis whether the outcomes in men with localized prostate cancer treated with high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT), by quantifying the effect of the total dose of radiotherapy on biochemical control (BC). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing HDRT with CDRT for localized prostate cancer. To evaluate the dose-response relationship, we conducted a meta-regression analysis of BC ratios by means of weighted linear regression. Results:more » Seven RCTs with a total patient population of 2812 were identified that met the study criteria. Pooled results from these RCTs showed a significant reduction in the incidence of biochemical failure in those patients with prostate cancer treated with HDRT (p < 0.0001). However, there was no difference in the mortality rate (p = 0.38) and specific prostate cancer mortality rates (p = 0.45) between the groups receiving HDRT and CDRT. However, there were more cases of late Grade >2 gastrointestinal toxicity after HDRT than after CDRT. In the subgroup analysis, patients classified as being at low (p = 0.007), intermediate (p < 0.0001), and high risk (p < 0.0001) of biochemical failure all showed a benefit from HDRT. The meta-regression analysis also detected a linear correlation between the total dose of radiotherapy and biochemical failure (BC = -67.3 + [1.8 x radiotherapy total dose in Gy]; p = 0.04). Conclusions: Our meta-analysis showed that HDRT is superior to CDRT in preventing biochemical failure in low-, intermediate-, and high-risk prostate cancer patients, suggesting that this should be offered as a treatment for all patients, regardless of their risk status.« less
2016-05-20
regular insulin has significantly increased in recent years. These patients are severely insulin resistant requiring high doses of insulin to achieve...on U-500 Insulin Admitted to the Hospital presented at SURF Conference, San Antonio, TX 20 May 201 6 with MDWI 41-108, and has been assigned local...59th CSPG/SGVU) C.201 4 . I 52d PROTOCOL TITLE Evaluation of Total Dai ly Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the
Hansen, Karen E.; Johnson, R. Erin; Chambers, Kaitlin R.; Johnson, Michael G.; Lemon, Christina C.; Thuy Vo, Tien Nguyen; Marvdashti, Sheeva
2015-01-01
Importance Experts debate optimal 25(OH)D levels for musculoskeletal health. Objective To compare effects of placebo, low-dose and high-dose vitamin D on one-year changes in total fractional calcium absorption, bone mineral density, Timed-Up-and-Go and 5-sit-to-stand tests and muscle mass in postmenopausal women with vitamin D insufficiency. Design Randomized, double-blind, placebo-controlled, clinical trial conducted from May 2010 to August 2014. Setting Single-center trial conducted in Madison, Wisconsin. Participants 230 postmenopausal women ≤75 years old with baseline 25(OH)D levels 14-27 ng/mL and no osteoporosis. Intervention Three arms included daily white and twice monthly yellow placebo (n=76), daily 800 IU vitamin D3 and twice monthly yellow placebo (n=76), and daily white placebo and twice monthly 50,000 IU vitamin D3 (n=79). The high-dose vitamin D regimen achieved and maintained 25(OH)D levels ≥30 ng/mL. Main Outcome Measures One year change in total fractional calcium absorption using two stable isotopes, bone mineral density and muscle mass using dual energy x-ray absorptiometry, Timed-Up-and-Go and 5-Sit-to-Stand tests, functional status (Health Assessment Questionnaire) and physical activity (Physical Activity Scale for the Elderly), with Benjamini-Hochberg correction of p-values to control the false discovery rate. Results After controlling for baseline absorption, calcium absorption increased 1% (10 mg/day) in the high-dose arm, but decreased by 2% in low-dose (p=0.005 vs. high-dose) and by 1.3% placebo (p=0.03 vs. high-dose) arms. We found no between-arm changes in spine, mean total hip, mean femoral neck or total body bone mineral density, trabecular bone score, muscle mass, 5-sit-to-stand or Timed-Up-and-Go test scores. Likewise, we found no between-arm differences for numbers of falls, number of fallers, physical activity or functional status. Conclusion and Relevance High-dose vitamin D therapy increased calcium absorption, but the effect was small and did not translate into beneficial effects on bone mineral density, muscle function, muscle mass or falls. We found no data to support experts’ recommendations to maintain serum 25(OH)D levels ≥30 ng/mL in postmenopausal women. Instead, we found that low and high-dose vitamin D were equivalent to placebo, in their effects on bone and muscle outcomes in this cohort of postmenopausal women with 25(OH)D levels <30 ng/mL. ClinicalTrials.gov.Identifier:NCT00933244 PMID:26237520
NASA Astrophysics Data System (ADS)
Mota, C. L.; Pickler, A.; Braz, D.; Barroso, R. C.; Mantuano, A.; Salata, C.; Ferreira-Machado, S. C.; Lau, C. C.; de Almeida, C. E.
2018-04-01
In the last decades, studies showed that the exposure to low doses of ionizing radiation of the body could sense and activate the cell signaling pathways needed to respond to any induced cellular damage. This procedure reduces cell killing compared with a single dose of high radiation dose. Damage to the vasculature can affect the function of most body organs by restricting blood flow and oxygen to tissues; however, the heart and brain are of main concern. The precise relationship between long-term health effects and low-dose exposures remain poorly understood. Biological markers are powerful tools that can be used to determine dose- response relationships and to estimate risk, especially when dealing with, the effects of low dose exposures in humans. These markers should be specific, sensitive, as well as easy and fast to quantify. Various types of biologic specimens are potential candidates for identifying biomarkers but blood has the advantage of being minimally invasive to obtain. In this study, we propose to apply total reflection X-ray fluorescence to quantify possible chemical elemental concentration (sulfer, iron, zinc, potassium and calcium) changes in blood and heart tissues of Wistar rats after total body irradiation with low (0.1 Gy) and high (2.5 Gy) doses. The fluorescence measurements were carried out at the X-ray Fluorescence beamline in the Brazilian Synchrotron Light Laboratory. The results showed that the irradiated animals with low doses have significant alterations in blood and cardiac tissue when compared with animals that received high doses of radiation. Taken together the analysis of all the elements, we can observe that the radiation induced oxidative stress may be the leading cause for alteration of the elemental level in the studied samples.
Controlled-release systemic delivery - a new concept in cancer chemoprevention
2012-01-01
Many chemopreventive agents have encountered bioavailability issues in pre-clinical/clinical studies despite high oral doses. We report here a new concept utilizing polycaprolactone implants embedded with test compounds to obtain controlled systemic delivery, circumventing oral bioavailability issues and reducing the total administered dose. Compounds were released from the implants in vitro dose dependently and for long durations (months), which correlated with in vivo release. Polymeric implants of curcumin significantly inhibited tissue DNA adducts following the treatment of rats with benzo[a]pyrene, with the total administered dose being substantially lower than typical oral doses. A comparison of bioavailability of curcumin given by implants showed significantly higher levels of curcumin in the plasma, liver and brain 30 days after treatment compared with the dietary route. Withaferin A implants resulted in a nearly 60% inhibition of lung cancer A549 cell xenografts, but no inhibition occurred when the same total dose was administered intraperitoneally. More than 15 phytochemicals have been tested successfully by this formulation. Together, our data indicate that this novel implant-delivery system circumvents oral bioavailability issues, provides continuous delivery for long durations and lowers the total administered dose, eliciting both chemopreventive/chemotherapeutic activities. This would also allow the assessment of activity of minor constituents and synthetic metabolites, which otherwise remain uninvestigated in vivo. PMID:22696595
Barrett, A; Depledge, M H; Powles, R L
1983-07-01
Idiopathic and infective interstitial pneumonitis (IPn) is a common complication after bone marrow transplantation (BMT) in many centers and carries a high mortality. We report here a series of 107 patients with acute leukemia grafted at the Royal Marsden Hospital in which only 11 (10.3%) developed IPn and only 5 died (5%). Only one case of idiopathic IPn was seen. Factors which may account for this low incidence are discussed. Sixty of 107 patients were transplanted in first remission of acute myeloid leukemia (AML) and were therefore in good general condition. Lung radiation doses were carefully monitored and doses of 10.5 Gy were not exceeded except in a group of 16 patients in whom a study of escalating doses of TBI (up to 13 Gy) was undertaken. The dose rate used for total body irradiation (TBI) was lower than that used in other centers and as demonstrated elsewhere by ourselves and others, reduction of dose rate to less than 0.05 Gy/min may be expected to lead to substantial reduction in lung damage. Threshold doses of approximately 8 Gy for IPn have been reported, but within the dose range of 8 to 10.5 Gy we suggest that dose rate may significantly affect the incidence. Data so far available suggest a true improvement in therapeutic ratio for low dose rate single fraction TBI compared with high dose rate.
Population dose commitments due to radioactive releases from nuclear power plant sites in 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1988. Fifty-year commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 71 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 16 person-rem to a low of 0.0011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.1 person-rem. The total population dose for all sites was estimated at 75 person-rem for the 150 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 3 {times} 10{sup {minus}7} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1988. Fifty-year commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 71 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 16 person-rem to a low of 0.0011 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 1.1 person-rem. The total population dose for all sites was estimated at 75 person-rem for the 150 million people considered at risk. The site average individual dose commitment from all pathways ranged from a low of 3 {times} 10{sup {minus}7} mrem to a high of 0.02 mrem. No attempt was made in this study to determine the maximum dose commitment received by any one individual from the radionuclides released at any of the sites. However, licensee calculation of doses to the maximally exposed individual at some sites indicated values of up to approximately 100 times average individual doses (on the order of a few millirem per year).« less
Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tube
NASA Technical Reports Server (NTRS)
Timothy, J. G.; Bybee, R. L.
1979-01-01
A multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.
A comparison of two methods of in vivo dosimetry for a high energy neutron beam.
Blake, S W; Bonnett, D E; Finch, J
1990-06-01
Two methods of in vivo dosimetry have been compared in a high energy neutron beam. These were activation dosimetry and thermoluminescence dosimetry (TLD). Their suitability was determined by comparison with estimates of total dose, obtained using a tissue equivalent ionization chamber. Measurements were made on the central axis and a profile of a 10 x 10 cm square field and also behind a shielding block in order to simulate conditions of clinical use. The TLD system was found to provide the best estimate of total dose.
Population dose commitments due to radioactive releases from nuclear power plant sites in 1980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.; Peloquin, R.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1980. In addition doses derived from the shutdown reactors at the Three Mile Island site were included. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showingmore » the fraction of the total population within 2 to 80 km around each site receiving various average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 40 person-rem to a low of 0.02 person-rem with an arithmetic mean of 4 person-rem. The total population dose for all sites was estimated at 180 person-rem for the 96 million people considered at risk.« less
Zeng, Zhikai; Li, Qingyun; Tian, Qiyu; Zhao, Panfeng; Xu, Xiao; Yu, Shukun; Piao, Xiangshu
2015-11-01
This study was conducted to evaluate the efficacy of a novel Buttiauxella phytase to pigs fed P-deficient, corn-soybean meal diets. One hundred and twenty crossbred piglets (9.53 ± 0.84 kg) were allocated to one of five treatments which consisted of four low P diets (0.61 % Ca and 0.46 % total P) supplemented with 0, 500, 1,000, or 20,000 FTU/kg phytase as well as a positive control diet (0.77 % Ca and 0.62 % total P). Each treatment had six replicated pens with four pigs per pen. Pigs were fed the experimental diets for 28 days. Phytase supplementation linearly improved (P < 0.05) average daily gain (ADG), feed conversion ratio (FCR), and apparent total tract digestibility (ATTD) of dry matter, gross energy, crude protein, Ca, and P in weaned pigs. Super high dosing with phytase (20,000 FTU/kg) further increased (P < 0.05) ADG compared with 500 FTU/kg phytase inclusion group, as well as ATTD of Ca and P. Metacarpal bone characteristics and several trace mineral concentration in bone, plasma, or organ tissues were linearly (P < 0.05) improved at increasing dose of phytase. Super high dosing with phytase (20,000 FTU/kg) supplementation improved (P < 0.05) Mn and Zn concentration in bone compared to normal dose of phytase supplementation (500 or 1,000 FTU/kg). In conclusion, supplementation of 500 FTU of Buttiauxella phytase/kg and above effectively hydrolyzed phytate in a low-P corn-soybean diet for pigs. In addition, a super high dosing with phytase (20,000 FTU/kg) improved macro- or micro mineral availability and growth performance.
Shkalim-Zemer, Vered; Ash, Shifra; Toledano, Helen; Kollender, Yehuda; Issakov, Josephine; Yaniv, Isaac; Cohen, Ian J
2015-11-01
Aggressive chemotherapy protocols for non-metastatic limb osteosarcoma have improved histological response without affecting prognosis. This study evaluated the toxicity and outcome of a dose-intensive, high-dose 3- to 5-drug pilot protocol, SCOS 89. The cohort included 26 patients (14 male; ages 6.5-22 years) with non-metastatic limb osteosarcoma treated at a tertiary pediatric medical center between 1989 and 2013. Preoperatively, patients received two courses of once-weekly pulses of high-dose methotrexate (12-30 g/m(2)) for 2 weeks; doxorubicin (90 mg/m(2)) with dexrazoxane, combined with cisplatin (200 mg/m(2)), was added in week 3. Following methotrexate, 760 mg/m(2) of folinic acid was administered. Postoperative chemotherapy was continued to a total of 14 courses of methotrexate, doxorubicin (up to a total dose of 360 mg/m(2)), and cisplatin (up to a total dose of 560 mg/m(2)). If toxicity occurred or <90 % tumor necrosis, ifosfamide (12 g/m(2)) plus etoposide (500 mg/m(2)) was substituted for doxorubicin, cisplatin, or methotrexate. Toxicity and death rates were calculated. All patients underwent definitive limb salvage surgery. Six patients died of infection, recurrent disease, or secondary malignancy. Median follow-up was 100 months (range 2-290). Event-free and overall survival rates, respectively, were 88 and 96 % at 2 years, 80 and 87.6 % at 5 years, 80 and 78 % at 10 years. Eleven patients required ifosfamide/etoposide substitution. One patient had a transient decreased left ventricular ejection fraction. Two patients developed acute nephrotoxicity during therapy, but no neurotoxicity. Seven patients had hearing impairment. The SCOS 89 yields a high event-free survival rate with reduced nephro-/neuro-/cardiotoxicity in patients with non-metastatic limb osteosarcoma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harriss-Phillips, Wendy M., E-mail: wharrphil@gmail.com; School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia; Bezak, Eva
Purpose: To simulate stereotactic ablative radiation therapy on hypoxic and well-oxygenated in silico tumors, incorporating probabilistic parameter distributions and linear-quadratic versus linear-quadratic-cubic methodology and the evaluation of optimal fractionation schemes using biological effective dose (BED{sub α/β=10} {sub or} {sub 3}) comparisons. Methods and Materials: A temporal tumor growth and radiation therapy algorithm simulated high-dose external beam radiation therapy using stochastic methods. Realistic biological proliferative cellular hierarchy and pO{sub 2} histograms were incorporated into the 10{sup 8}-cell tumor model, with randomized radiation therapy applied during continual cell proliferation and volume-based gradual tumor reoxygenation. Dose fractions ranged from 6-35 Gy, with predictive outcomes presentedmore » in terms of the total doses (converted to BED) required to eliminate all cells that could potentially regenerate the tumor. Results: Well-oxygenated tumor control BED{sub 10} outcomes were not significantly different for high-dose versus conventional radiation therapy (BED{sub 10}: 79-84 Gy; Equivalent Dose in 2 Gy fractions with α/β of 10: 66-70 Gy); however, total treatment times decreased from 7 down to 1-3 weeks. For hypoxic tumors, an additional 28 Gy (51 Gy BED{sub 10}) was required, with BED{sub 10} increasing with dose per fraction due to wasted dose in the final fraction. Fractions of 9 Gy compromised well for total treatment time and BED, with BED{sub 10}:BED{sub 3} of 84:176 Gy for oxic and 132:278 Gy for non-reoxygenating hypoxic tumors. Initial doses of 12 Gy followed by 6 Gy further increased the therapeutic ratio. When delivering ≥9 Gy per fraction, applying reoxygenation and/or linear-quadratic-cubic cell survival both affected tumor control doses by a significant 1-2 fractions. Conclusions: The complex temporal dynamics of tumor oxygenation combined with probabilistic cell kinetics in the modeling of radiation therapy requires sophisticated stochastic modeling to predict tumor cell kill. For stereotactic ablative radiation therapy, high doses in the first week followed by doses that are more moderate may be beneficial because a high percentage of hypoxic cells could be eradicated early while keeping the required BED{sub 10} relatively low and BED{sub 3} toxicity to tolerable levels.« less
Pireau, Nathalie; Cordemans, Virginie; Banse, Xavier; Irda, Nadia; Lichtherte, Sébastien; Kaminski, Ludovic
2017-11-01
Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable). A prospective randomized trial was conducted in the hybrid operating room between December 2015 and December 2016, including 50 patients operated on for posterior instrumented thoracic and/or lumbar spinal fusion. Patients were randomized to intraoperative 3D acquisition high-dose (standard dose) or low-dose protocol, and a total of 216 pedicle screws were analyzed in terms of screw position. Two different methods were used to measure ionizing radiation: the total skin dose (derived from the dose-area product) and the radiation dose evaluated by thermoluminescent dosimeters on the surgical field. According to Gertzbein and Heary classifications, low-dose protocol provided a significant higher accuracy of pedicle screw placement than the high-dose protocol (96.1 versus 92%, respectively). Seven screws (3.2%), all implanted with the high-dose protocol, needed to be revised intraoperatively. The use of low-dose acquisition protocols reduced patient exposure by a factor of five. This study emphasizes the paramount importance of using low-dose protocols for intraoperative cone beam CT imaging coupled with the navigation system, as it at least does not affect the accuracy of pedicle screw placement and irradiates drastically less.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, W.G.
2001-08-16
The offsite radiological effects from high velocity straight winds, tornadoes, and earthquakes have been estimated for a proposed facility for manufacturing enriched uranium fuel cores by powder metallurgy. Projected doses range up to 30 mrem/event to the maximum offsite individual for high winds and up to 85 mrem/event for very severe earthquakes. Even under conservative assumptions on meteorological conditions, the maximum offsite dose would be about 20 per cent of the DOE limit for accidents involving enriched uranium storage facilities. The total dose risk is low and is dominated by the risk from earthquakes. This report discusses this test.
NASA Astrophysics Data System (ADS)
Lucero, J. F.; Rojas, J. I.
2016-07-01
Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient's entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt; Hope International, Guatemala; Rojas, J. I., E-mail: isaac.rojas@siglo21.cr
Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.
Christakopoulos, Georgios E.; Christopoulos, Georgios; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W.; Jaffer, Farouc A.; Wyman, Michael R.; Lombardi, William L.; Tarar, Muhammad Nauman J.; Grantham, J. Aaron; Kandzari, David; Lembo, Nicholas; Moses, Jeffrey W.; Kirtane, Ajay; Parikh, Manish; Green, Philip; Finn, Matthew; Garcia, Santiago; Doing, Anthony; Hatem, Raja; Thompson, Craig A.; Banerjee, Subhash; Brilakis, Emmanouil S.
2016-01-01
Background High patient radiation dose during chronic total occlusion (CTO) percutaneous coronary intervention (PCI) may lead to procedural failure and radiation skin injury. Methods We examined the association between several clinical and angiographic variables on patient air kerma (AK) radiation dose among 748 consecutive CTO PCIs performed at 9 experienced US centers between May 2012 and May 2015. Results Mean age was 65±10 years, 87% of patients were men, and 35% had prior coronary artery bypass graft surgery (CABG). Technical and procedural success was 92% and 90%, respectively. The median patient AK dose was 3.40 (2.00, 5.40) Gray and 34% of the patients received >4.8 Gray (high radiation exposure). On univariable analysis male gender (p=0.016), high body mass index (p<0.001), history of hyperlipidemia (p=0.023), prior CABG (p<0.001), moderate or severe calcification (p<0.001), tortuosity (p<0.001), proximal cap ambiguity (p=0.001), distal cap at a bifurcation (p=0.006), longer CTO occlusion length (p<0.001), blunt/no blunt stump (p<0.001), and center (<0.001) were associated with higher patient AK dose. On multivariable analysis high body mass index (p<0.001), prior CABG (p=0.005), moderate or severe calcification (p=0.005), longer CTO occlusion length (p<0.001), and center (p<0.001) were independently associated with higher patient AK dose. Conclusions Approximately 1 in 3 patients undergoing CTO PCI receives high AK radiation dose (>4.8 Gray). Several baseline clinical and angiographic characteristics can help predict the likelihood of high radiation dose and assist with intensifying efforts to reduce radiation exposure for the patient and the operator. PMID:28169091
Relevant tumor sink effect in prostate cancer patients receiving 177Lu-PSMA-617 radioligand therapy.
Filss, Christian; Heinzel, Alexander; Miiller, Berthold; Vogg, Andreas T J; Langen, Karl-Josef; Mottaghy, Felix M
2018-02-01
In metastatic prostate cancer patients PSMA targeting radioligands have gained significant impact as theranostic probes. In this study a correlation between total tumor volume (TTV) and measured kidney dose as well as salivary glands (SG) uptake in 177 Lu-PSMA-617 therapy was evaluated. Eleven consecutive prostate cancer patients receiving a first cylcle of 177 Lu-PSMA-617 (administered activity of approximately 6GBq) were included. The 68 Ga-PSMA-11 PET/CT scan previous to therapy was used to determine TTV and SG uptake (glandulae submandibularis) employing PMOD version 3.403 with different 68 Ga-PSMA-11 thresholds based on the standardized uptake value (SUV).The kidney dose was estimated with the software ULMDOS using planar whole-body scintigrams. Kidney dose and SG uptake was inversely correlated to TTV, indicating high kidney dose and high SG uptake in case of low tumor load and low kidney dose and low SG uptake in case of high tumor load. Our data support the hypothesis that in 177 Lu-PSMA-617 therapy an individualized treatment activity based on total tumor volume could be beneficiary. Schattauer GmbH.
Sinakos, Emmanouil; Marschall, Hanns-Ulrich; Kowdley, Kris V.; Befeler, Alex; Keach, Jill; Lindor, Keith
2010-01-01
High-dose (28-30mg/kg/day) ursodeoxycholic acid (UDCA) treatment improves serum liver tests in patients with primary sclerosing cholangitis (PSC) but does not improve survival and is associated with increased rates of serious adverse events. The mechanism for the latter undesired effect remains unclear. High-dose UDCA could result in the production of hepatotoxic bile acids, such as lithocholic acid (LCA), due to limited small bowel absorption of UDCA and conversion of UDCA by bacteria in the colon. We determined the serum bile acid composition in 56 patients with PSC previously enrolled in a randomized, double-blind controlled trial of high dose UDCA versus placebo. Samples for analysis were obtained at baseline and at the end of treatment. The mean changes in UDCA (16.86 vs 0.05 μmol/L) and total bile acid (17.21 vs −0.55 μmol/L) levels were significantly higher in the UDCA group (n=29) compared to placebo (n=27) when pretreatment levels were compared (p<0.0001). LCA was also markedly increased (0.22 vs 0.01 μmol/L) in the UDCA group compared to placebo (p=0.001). No significant changes were detected for cholic acid (CA), deoxycholic acid (DCA) and chenodeoxycholic acid (CDCA). Patients (n=9) in the UDCA group who reached clinical endpoints of disease progression (development of cirrhosis, varices, liver transplantation or death) tend to have greater increase in their post-treatment total bile acid levels (34.99 vs 9.21 μmol/L) (p<0.08) compared to those who did not. Conclusion High-dose UDCA treatment in PSC patients results in marked UDCA enrichment and significant expansion of the total serum bile acid pool including lithocholic acid. PMID:20564380
β-blocker dosage and outcomes after acute coronary syndrome.
Allen, Jason E; Knight, Stacey; McCubrey, Raymond O; Bair, Tami; Muhlestein, Joseph Brent; Goldberger, Jeffrey J; Anderson, Jeffrey L
2017-02-01
Although β-blockers increase survival in acute coronary syndrome (ACS) patients, the doses used in trials were higher than doses used in practice, and recent data do not support an advantage of higher doses. We hypothesized that rates of major adverse cardiac events (MACE), all-cause death, myocardial infarction, and stroke are equivalent for patients on low-dose and high-dose β-blocker. Patients admitted to Intermountain Healthcare with ACS and diagnosed with ≥70% coronary stenosis between 1994 and 2013 were studied (N = 7,834). We classified low dose as ≤25% and high dose as ≥50% of an equivalent daily dose of 200 mg of metoprolol. Multivariate analyses were used to test association between low-dose versus high-dose β-blocker dosage and MACE at 0-6 months and 6-24 months. A total of 5,287 ACS subjects were discharged on β-blockers (87% low dose, 12% high dose, and 1% intermediate dose). The 6-month MACE outcomes rates for the β-blocker dosage (low versus high) were not equivalent (P = .18) (hazard ratio [HR] = 0.76; 95% CI, 0.52-1.10). However, subjects on low-dose β-blocker therapy did have a significantly decreased risk of myocardial infarction for 0-6 months (HR = 0.53; 95% CI, 0.33-0.86). The rates of MACE events during the 6-24 months after presentation with ACS were equivalent for the 2 doses (P = .009; HR = 1.03 [95% CI, 0.70-1.50]). In ACS patients, rates of MACE for high-dose and low-dose β-blocker doses are similar. These findings question the importance of achieving a high dose of β-blocker in ACS patients and highlight the need for further investigation of this clinical question. Copyright © 2016 Elsevier Inc. All rights reserved.
Population dose commitments due to radioactive releases from nuclear power plant sites in 1983
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.; Peloquin, R.A.
Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1983. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 52 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km aroundmore » each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 45 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 170 person-rem for the 100 million people considered at risk.« less
Lenka, Pradyumna; Sahoo, S K; Mohapatra, S; Patra, A C; Dubey, J S; Vidyasagar, D; Tripathi, R M; Puranik, V D
2013-03-01
A natural high background radiation area is located in Chhatrapur, Odisha in the eastern part of India. The inhabitants of this area are exposed to external radiation levels higher than the global average background values, due to the presence of uranium, thorium and its decay products in the monazite sands bearing placer deposits in its beaches. The concentrations of (232)Th, (238)U, (226)Ra, (40)K and (137)Cs were determined in cereals (rice and wheat), pulses and drinking water consumed by the population residing around this region and the corresponding annual ingestion dose was calculated. The annual ingestion doses from cereals, pulses and drinking water varied in the range of 109.4-936.8, 10.2-307.5 and 0.5-2.8 µSv y(-1), respectively. The estimated total annual average effective dose due to the ingestion of these radionuclides in cereals, pulses and drinking water was 530 µSv y(-1). The ingestion dose from cereals was the highest mainly due to a high consumption rate. The highest contribution of dose was found to be from (226)Ra for cereals and drinking water and (40)K was the major dose contributor from the intake of pulses. The contribution of man-made radionuclide (137)Cs to the total dose was found to be minimum. (226)Ra was found to be the largest contributor to ingestion dose from all sources.
Chit, Ayman; Becker, Debbie L; DiazGranados, Carlos A; Maschio, Michael; Yau, Eddy; Drummond, Michael
2015-12-01
Adults aged 65 years and older account for most seasonal influenza-related hospital admissions and deaths. Findings from the randomised controlled FIM12 study showed that high-dose inactivated influenza vaccine is more effective than standard-dose vaccine for prevention of laboratory-confirmed influenza in this age group. We aimed to assess the economic impact of high-dose versus standard-dose influenza vaccine in participants in the FIM12 study population. The FIM12 study was a head-to-head randomised controlled trial in which 31,989 participants aged 65 years and older were randomly assigned (1:1) to receive either high-dose or standard-dose trivalent inactivated influenza vaccine over two influenza seasons (2011-12 and 2012-13). Data for health-care resource consumption obtained in the FIM12 study were summarised across vaccine groups. Unit costs obtained from standard US cost sources were applied to each resource item, including to the vaccines (high dose US$31·82, standard dose $12·04). Clinical illness data were mapped to existing quality-of-life data. The time horizon was one influenza season; however, quality-adjusted life-years (QALYs) lost due to death during the study were calculated over a lifetime. We calculated incremental cost-effectiveness ratios (ICERs) for high-dose versus standard-dose vaccine and used QALYs as an outcome in the cost-utility analysis. We undertook a probabilistic sensitivity analysis using bootstrapping to explore the effect of statistical uncertainty on the study results. Mean per-participant medical costs were lower in the high-dose vaccine group ($1376·72 [SD 6857·59]) than in the standard-dose group ($1492·64 [7447·14]; difference -$115·92 [95% CI -264·18 to 35·48]). Mean societal costs were likewise lower in the high-dose versus the standard-dose group ($1506·48 [SD 7305·19] vs $1634·50 [7952·99]; difference -$128·02 [95% CI -286·89 to 33·30]). Hospital admissions contributed 95% of the total health-care-payer cost and 87% of the total societal costs. The mean per-participant number of hospital admissions was 0·0937 (SD 0·3644) in the high-dose group and 0·1017 (0·3708) in the standard-dose group (difference -0·0080, 95% CI -0·0160 to -0·0003). The high-dose vaccine provided a gain in QALYs (mean 8·1502 QALYs gained per participant [SD 0·5693]) compared with the standard-dose vaccine (8·1499 QALYs [0·5697]) and, due to cost savings, dominated standard-dose vaccine in the cost-utility analysis. The probabilistic sensitivity analysis showed that the high-dose vaccine is 93% likely to be cost saving. High-dose trivalent inactivated influenza vaccine is a less costly and more effective alternative to the standard-dose vaccine, driven by a reduction in the number of hospital admissions. These findings are relevant to US health-care beneficiaries, providers, payers, and recommending bodies, especially those seeking to improve outcomes while containing costs. Sanofi Pasteur. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Protective effect of emodin pretreatment in young rats with intrahepatic cholestasis].
Xiong, Xiao-Li; Yan, Su-Qi; Qin, Huan; Zhou, Li-Shan; Zhang, Ling-Ling; Jiang, Zhi-Xia; Ding, Yan
2016-02-01
To investigate the protective effect of emodin in young rats with intrahepatic cholestasis. A total of 120 young Sprague-Dawley rats were randomly divided into control, model, and high-, medium-, and low-dose emodin groups, with 24 rats in each group. The rats in the control and model groups were given sodium carboxymethyl cellulose solution by gavage, while the other groups were given different doses of emodin solution by gavage. On the 5th day of experiment, alpha-naphthylisothiocyanate (ANIT, 50 mg/kg) was applied by gavage to establish the model of intrahepatic cholestasis in all groups except the control group. At 24, 48, and 72 hours after gavage, 8 rats in each group were sacrificed. Colorimetry was used to measure the serum levels of total bilirubin (TBIL), direct bilirubin (DBIL), total bile acid (TBA), alkaline phosphatase (ALP), gamma glutamyl transpeptidase (GGT), alanine aminotransferase (ALT), and aspartate aminotransferase (AST) in each group, and hematoxylin-eosin staining was applied to observe the morphological changes of the liver under a light microscope at different time points. Compared with the control group, the model group had significantly increased serum levels of TBIL, DBIL, TBA, ALP, GGT, ALT, and AST at the 24-hour, 48-hour, and 72-hour time points (P<0.01). In the model group, the serum levels of TBIL, DBIL, TBA, ALT, and AST showed varying degrees of increase at 48 hours after establishment of model, compared with the values at 24 and 72 hours (P<0.05). At 24, 48, and 72 hours, the high-, medium-, and low-dose emodin groups had varying degrees of reductions in the serum levels of TBIL and TBA compared with the model group (P<0.05); the high- and low-dose emodin groups had significantly increased serum levels of TBA compared with the medium-dose emodin group (P<0.05). The model group had the most severe pathological changes at 48 hours. Compared with the model group, the high-, medium-, and low-dose emodin groups showed certain improvement in pathological changes of the liver at each time point, and the medium-dose emodin group had better improvement compared with the high- and low-dose emodin groups. Emodin can effectively improve ANIT-induced intrahepatic cholestasis in young rats, and medium-dose emodin shows the best effect.
Zelefsky, Michael J; Greco, Carlo; Motzer, Robert; Magsanoc, Juan Martin; Pei, Xin; Lovelock, Michael; Mechalakos, Jim; Zatcky, Joan; Fuks, Zvi; Yamada, Yoshiya
2014-01-01
Purpose To report tumor local progression-free outcomes following treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) and hypofractionated regimens for extracranial metastases from renal cell primary tumors. Methods and Materials Between 2004 and 2010, a total of 105 lesions from renal cell carcinomas were treated with either SD-IGRT to prescription doses of 18–24 Gy (median, 24 Gy) or hypofractionation (3 or 5 fractions) with prescription doses ranging between 20 and 30 Gy. The median follow-up was 12 months (range, 1–48 months). Results The overall 3-year actuarial local progression-free survival (LPFS) for all lesions was 44%. The 3-year LPFS for those who received high single-dose (24 Gy; n = 45), low single-dose (< 24 Gy; n = 14), and hypofractionation regimens (n = 46) were 88%, 21%, and 17%, respectively (high single dose versus low single dose, p = 0.001; high single dose versus hypofractionation, p < 0.001). Multivariate analysis revealed the following variables as significant predictors of improved LPFS: dose of 24 Gy compared with lower dose (p = 0.009), and single dose versus hypofractionation (p = 0.008). Conclusion High-dose SD-IGRT is a non-invasive procedure resulting in high probability of local tumor control for metastatic renal cell cancers, generally considered radioresistant according to classical radiobiological ranking. PMID:21596489
High brachytherapy doses can counteract hypoxia in cervical cancer—a modelling study
NASA Astrophysics Data System (ADS)
Lindblom, Emely; Dasu, Alexandru; Beskow, Catharina; Toma-Dasu, Iuliana
2017-01-01
Tumour hypoxia is a well-known adverse factor for the outcome of radiotherapy. For cervical tumours in particular, several studies indicate large variability in tumour oxygenation. However, clinical evidence shows that the management of cervical cancer including brachytherapy leads to high rate of success. It was the purpose of this study to investigate whether the success of brachytherapy for cervical cancer, seemingly regardless of oxygenation status, could be explained by the characteristics of the brachytherapy dose distributions. To this end, a previously used in silico model of tumour oxygenation and radiation response was further developed to simulate the treatment of cervical cancer employing a combination of external beam radiotherapy and intracavitary brachytherapy. Using a clinically-derived brachytherapy dose distribution and assuming a homogeneous dose delivered by external radiotherapy, cell survival was assessed on voxel level by taking into account the variation of sensitivity with oxygenation as well as the effects of repair, repopulation and reoxygenation during treatment. Various scenarios were considered for the conformity of the brachytherapy dose distribution to the hypoxic region in the target. By using the clinically-prescribed brachytherapy dose distribution and varying the total dose delivered with external beam radiotherapy in 25 fractions, the resulting values of the dose for 50% tumour control, D 50, were in agreement with clinically-observed values for high cure rates if fast reoxygenation was assumed. The D 50 was furthermore similar for the different degrees of conformity of the brachytherapy dose distribution to the tumour, regardless of whether the hypoxic fraction was 10%, 25%, or 40%. To achieve 50% control with external RT only, a total dose of more than 70 Gy in 25 fractions would be required for all cases considered. It can thus be concluded that the high doses delivered in brachytherapy can counteract the increased radioresistance caused by hypoxia if fast reoxygenation is assumed.
Boucher, Bradley A; Hudson, Joanna Q; Hill, David M; Swanson, Joseph M; Wood, G Christopher; Laizure, S Casey; Arnold-Ross, Angela; Hu, Zhe-Yi; Hickerson, William L
2016-12-01
High-dose continuous venovenous hemofiltration (CVVH) is a continuous renal replacement therapy (CRRT) used frequently in patients with burns. However, antibiotic dosing is based on inference from studies assessing substantially different methods of CRRT. To address this knowledge gap for imipenem/cilastatin (I/C), we evaluated the systemic and extracorporeal clearances (CLs) of I/C in patients with burns undergoing high-dose CVVH. Prospective clinical pharmacokinetic study. Ten adult patients with burns receiving I/C for a documented infection and requiring high-dose CVVH were studied. Blood and effluent samples for analysis of I/C concentrations were collected for up to 6 hours after the I/C infusion for calculation of I/C total CL (CL T otal ), CL by CVVH (CL HF ), half-life during CVVH, volume of distribution at steady state (Vd ss ), and the percentage of drug eliminated by CVVH. In this patient sample, the mean age was 50 ± 17 years, total body surface area burns was 23 ± 27%, and 80% were male. Nine patients were treated with high-dose CVVH for acute kidney injury and one patient for sepsis. The mean delivered CVVH dose was 52 ± 14 ml/kg/hour (range 32-74 ml/kg/hr). The imipenem CL HF was 3.27 ± 0.48 L/hour, which accounted for 23 ± 4% of the CL T otal (14.74 ± 4.75 L/hr). Cilastatin CL HF was 1.98 ± 0.56 L/hour, which accounted for 45 ± 19% of the CL T otal (5.16 + 2.44 L/hr). The imipenem and cilastatin half-lives were 1.77 ± 0.38 hours and 4.21 ± 2.31 hours, respectively. Imipenem and cilastatin Vd ss were 35.1 ± 10.3 and 32.8 ± 13.8 L, respectively. Efficient removal of I/C by high-dose CVVH, a high overall clearance, and a high volume of distribution in burn intensive care unit patients undergoing this CRRT method warrant aggressive dosing to treat serious infections effectively depending on the infection site and/or pathogen. © 2016 Pharmacotherapy Publications, Inc.
Hohaus, S; Funk, L; Martin, S; Schlenk, R F; Abdallah, A; Hahn, U; Egerer, G; Goldschmidt, H; Schneeweiß, A; Fersis, N; Kaul, S; Wallwiener, D; Bastert, G; Haas, R
1999-01-01
We report on the efficacy and toxicity of a sequential high-dose therapy with peripheral blood stem cell (PBSC) support in 85 patients with high-risk stage II/III breast cancer. There were 71 patients with more than nine tumour-positive axillary lymph nodes. An induction therapy of two cycles of ifosfamide (total dose, 7.5 g m−2) and epirubicin (120 mg m−2) was given, and PBSC were harvested during G-CSF-supported leucocyte recovery following the second cycle. The PBSC-supported high-dose chemotherapy consisted of two cycles of ifosfamide (total dose, 12 000 mg m−2), carboplatin (900 mg m−2) and epirubicin (180 mg m−2). Patients were autografted with a median number of 3.7 × 106 CD34+ cells kg−1 (range, 1.9–26.5 × 106) resulting in haematological reconstitution within approximately 2 weeks following high-dose therapy. The toxicity was moderate in general, and there was no treatment-related toxic death. Twenty-one patients relapsed between 3 and 30 months following the last cycle of high-dose therapy (median, 11 months). The probability of disease-free and overall survival at 4 years were 60% and 83%, respectively. According to a multivariate analysis, patients with stage II disease had a significantly better probability of disease-free survival (74%) in comparison to patients with stage III disease (36%). The probability of disease-free survival was also significantly better for patients with oestrogen receptor-positive tumours (70%) compared to patients with receptor-negative ones (40%). Bone marrow samples collected from 52 patients after high-dose therapy were examined to evaluate the prognostic relevance of isolated tumour cells. The proportion of patients presenting with tumour cell-positive samples did not change in comparison to that observed before high-dose therapy (65% vs 71%), but a decrease in the incidence and concentration of tumour cells was observed over time after high-dose therapy. This finding was true for patients with relapse and for those in remission, which argues against a prognostic significance of isolated tumour cells in bone marrow. In conclusion, sequential high-dose chemotherapy with PBSC support can be safely administered to patients with high-risk stage II/III breast cancer. Further intensification of the therapy, including the addition of non-cross resistant drugs or immunological approaches such as the use of antibodies against HER-2/NEU, may be envisaged for patients with stage III disease and hormone receptor-negative tumours. © 1999 Cancer Research Campaign PMID:10188897
Dharmarajan, Satheesh Kumar; Arumugam, Kottai Muthu
2012-10-02
The objective of the study is a comparative evaluation of flavone isolated from Mucuna pruriens and coumarin isolated from Ionidium suffruticosum was assessed for the hypolipidemic activity in rats fed with high fat diet. The acute toxicity study was found that flavone (M.pruriens) and coumarin (I.suffruticosum) are safe up to 100 mg/kg, so one tenth of this dose (10 mg/kg) was consider as a evaluation dose. High fat diet group of rats showed significant (p<0.001) elevation in plasma total and LDL-cholesterol, triglycerides and phospholipids. Administration of flavone (M. pruriens) and coumarin isolated from (I.suffruticosum) at the dose of 10mg/kg b.wt/day along with high fat diet significantly (p<0.001) prevented the rise in the plasma total and LDL-cholesterol, triglycerides and phospholipids than that of other extracts. However, treatment of coumarin isolated from (I.suffruticosum) had showed more cardio protective effect against hyperlipidemia than that of flavone (M.pruriens).
Tagariello, G; De Biasi, E; Gajo, G B; Risato, R; Radossi, P; Davoli, P G; Traldi, A
2000-09-01
In this report we describe our experience of total hip replacement in two patients with severe haemophilia A and high titres of inhibitors to FVIII. We used rFVIIa replacement therapy by continuous infusion to perform the surgery. The total amount of rFVIIa used in these two patients was very similar but the manner of administration was quite different. In our experience, it is an advantage to use a higher dose for shorter periods than a lower dose for a longer treatment period. Tranexamic acid by continuous infusion, and parallel saline infusion were useful for good haemostasis and avoided local thrombophlebitis in the side of rFVIIa infusion.
Johnson, Daniel J; Johnson, Christine C; Goobie, Susan M; Nami, Nina; Wetzler, Joshua A; Sponseller, Paul D; Frank, Steven M
2017-12-01
Our objective was to quantify blood loss and transfusion requirements for high-dose and low-dose tranexamic acid (TXA) dosing regimens in pediatric patients undergoing spinal fusion for correction of idiopathic scoliosis. Previous investigators have established the efficacy of TXA in pediatric scoliosis surgery; however, the dosing regimens vary widely and the optimal dose has not been established. We retrospectively analyzed electronic medical records for 116 patients who underwent spinal fusion surgery for idiopathic scoliosis by a single surgeon and were treated with TXA. In total, 72 patients received a 10 mg/kg loading dose with a 1 mg/kg/h maintenance dose (low-dose) and 44 patients received 50 mg/kg loading dose with a 5 mg/kg/h maintenance dose (high-dose). Estimated blood loss and transfusion requirements were compared between dosing groups. Patient characteristics were nearly identical between the 2 groups. Compared with the low-dose TXA group, the high-dose TXA group had decreased estimated blood loss (695 vs. 968 mL, P=0.01), and a decrease in both intraoperative (0.3 vs. 0.9 units, P=0.01) and whole hospitalization (0.4 vs. 1.0 units, P=0.04) red blood cell transfusion requirements. The higher-dose TXA was associated with decreased intraoperative (P=0.01), and whole hospital transfusion (P=0.01) requirements, even after risk-adjustment for potential confounding variables. High-dose TXA is more effective than low-dose TXA in reducing blood loss and transfusion requirements in pediatric idiopathic scoliosis patients undergoing surgery. Level-III, retrospective cohort study.
Mechanisms of Radiation Induced Effects in Carbon Nanotubes
2016-10-01
the defect types created for both ionizing and non-ionizing particles under exposure to high total ionization and displacement damage doses. Carbon...and displacement damage doses. Additionally, the radiation effects on CNT carrier transport parameters (mobility, lifetime, conductivity) have been...thermal oxidation. 2. Radiation Testing of SWCNTs 2.1 Displacement Damage Dose Effects as a Function of SWCNT Electronic-Type Displacement damage does
High-dose anti-histamine use and risk factors in children with urticaria.
Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu
2016-12-01
The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p<0.0001). There was no difference between the two groups in terms of blood eosinophil and basophil counts, and serum total IgE levels (p>0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=-0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03-1.15]) and basopenia (OR: 6.77; CI 95%: [2.01-22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. The requirement of high-dose H1-antihistamines was higher with children's increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines.
Chen, Gang; Zhang, Jun; Zhang, Yuzhe; Liao, Peng; Li, Tiejun; Chen, Lixiang; Yin, Yulong; Wang, Jinquan; Wu, Guoyao
2014-01-01
This experiment was conducted to investigate the effects of oral administration of monosodium glutamate (MSG) on expression of genes for hepatic lipid and nitrogen metabolism in piglets. A total of 24 newborn pigs were assigned randomly into one of four treatments (n = 6/group). The doses of oral MSG administration, given at 8:00 and 18:00 to sow-reared piglets between 0 and 21 days of age, were 0 (control), 0.06 (low dose), 0.5 (intermediate dose), and 1 (high dose) g/kg body weight/day. At the end of the 3-week treatment, serum concentrations of total protein and high-density lipoprotein cholesterol in the intermediate dose group were elevated than those in the control group (P < 0.05). Hepatic mRNA levels for fatty acid synthase, acetyl-coA carboxylase, insulin-like growth factor-1, glutamate-oxaloacetate transaminase, and glutamate-pyruvate transaminase were higher in the middle-dose group (P < 0.05), compared with the control group. MSG administration did not affect hepatic mRNA levels for hormone-sensitive lipase or carnitine palmitoyl transferase-1. We conclude that oral MSG administration alters hepatic expression of certain genes for lipid and nitrogen metabolism in suckling piglets.
Luedtke, Brandon E; Bosilevac, Joseph M; Harhay, Dayna M; Arthur, Terrance M
2016-04-01
Contamination of beef products by Shiga toxin-producing Escherichia coli is a concern for food safety with a particular subset, the enterohemorrhagic E. coli (EHEC), being the most relevant to human disease. To mitigate food safety risks, preharvest intervention strategies have been implemented with the aim to reduce EHEC in cattle. One class of interventions that has been widely used in feedlots is direct-fed microbials (DFMs), which can contain various dosing rates of probiotic bacteria. Here we compare the use of two different doses of a commercially available DFM on total EHEC load in a commercial feedlot setting. The DFMs used were the standard 10(9) Propionibacterium freudenreichii and 10(6) Lactobacillus acidophilus colony forming units (CFUs)/head/day dose of Bovamine(®) (Nutrition Physiology Company, Guymon, OK) and the higher dose, Bovamine Defend™ (Nutrition Physiology Company), which is dosed at 10(9) P. freudenreichii and 10(9) Lactobacillus acidophilus CFUs/head/day. To analyze the total EHEC fecal concentration, 2200 head of cattle were assigned a DFM feed regimen lasting approximately 5 months. At harvest, 480 head of cattle were sampled using rectoanal mucosal swabs. A quantitative polymerase chain reaction assay targeting ecf1 was used to enumerate the total EHEC fecal concentration for 240 head fed the low-dose DFM and 240 head fed the high-dose DFM. No significant difference (p > 0.05) in the fecal concentration of total EHEC was observed between the two doses. This suggests that using an increased dosage provides no additional reduction in the total EHEC fecal concentration of feedlot cattle compared to the standard dosage.
Response of Intestinal Bacterial Flora to the Long-term Feeding of Aflatoxin B1 (AFB1) in Mice.
Yang, Xiai; Liu, Liangliang; Chen, Jing; Xiao, Aiping
2017-10-12
In order to investigate the influence of aflatoxin B1 (AFB1) on intestinal bacterial flora, 24 Kunming mice (KM mice) were randomly placed into four groups, which were labeled as control, low-dose, medium-dose, and high-dose groups. They were fed intragastrically with 0.4 mL of 0 mg/L, 2.5 mg/L, 4 mg/L, or 10 mg/L of AFB1 solutions, twice a day for 2 months. The hypervariable region V3 + V4 on 16S rDNA of intestinal bacterial flora was sequenced by the use of a high-flux sequencing system on a Miseq Illumina platform; then, the obtained sequences were analyzed. The results showed that, when compared with the control group, both genera and phyla of intestinal bacteria in the three treatment groups decreased. About one third of the total genera and one half of the total phyla remained in the high-dose group. The dominant flora were Lactobacillus and Bacteroides in all groups. There were significant differences in the relative abundance of intestinal bacterial flora among groups. Most bacteria decreased as a whole from the control to the high-dose groups, but several beneficial and pathogenic bacterial species increased significantly with increasing dose of AFB1. Thus, the conclusion was that intragastric feeding with 2.5~10 mg/mL AFB1 for 2 months could decrease the majority of intestinal bacterial flora and induce the proliferation of some intestinal bacteria flora.
Elias, A D; Wheeler, C; Ayash, L J; Schwartz, G; Ibrahim, J; Mills, L; McCauley, M; Coleman, N; Warren, D; Schnipper, L; Antman, K H; Teicher, B A; Frei, E
1998-06-01
Multiple mechanisms of drug resistance contribute to treatment failure. Although high-dose therapy attempts to overwhelm these defenses pharmacologically, this approach is only successful in a fraction of treated patients. Many drug resistance mechanisms are shared between malignant and normal cells, but the expression of various drug resistance mechanisms associated with hypoxia is largely confined to tumor tissue. Thus, reversal of this mechanism is likely to provide a therapeutic advantage to the host. This study was designed to define the dose-limiting toxicities and maximum tolerated dose of etanidazole when it is given concurrently with high-dose ifosfamide, carboplatin, and etoposide (ICE), with hematopoietic stem cell support. The maximum tolerated doses of high-dose ICE were administered concurrently with dose escalations of etanidazole, a hypoxic cell sensitizer. All agents were given by 96-h continuous i.v. infusion beginning on day -7. Mesna uroprotection was provided. Autologous marrow and cytokine mobilized peripheral blood progenitor cells were reinfused on day 0. Granulocyte colony-stimulating factor was administered following reinfusion until the granulocytes recovered to > 1000/microliter. Fifty-five adults with advanced malignancies were enrolled in cohorts of five to nine patients. Four dose levels of etanidazole between 3 and 5.5 g/m2/day (12, 16, 20, and 22 g/m2 total doses) and two doses of carboplatin (1600 and 1800 mg/m2 total doses) were evaluated. Seven patients died of organ toxicity (13%); two each from veno-occlusive disease of liver and sepsis; and one each from sudden death, renal failure, and refractory thrombocytopenic hemorrhage. Five deaths occurred at the top dose level. One additional patient suffered a witnessed cardiorespiratory arrest from ventricular fibrillation and was resuscitated. Dose-dependent and largely reversible peripheral neuropathy was observed consisting of two syndromes: severe cramping myalgic/neuralgic pain, predominantly in stocking glove distribution, occurring between day -3 and day 0, and a sensory peripheral neuropathy with similar distribution peaking around day +60. The maximal achievable dose of etanidazole (16 g/m2 dose level) resulted in a mean serum level of 38 micrograms/ml (25-55 micrograms/ml). Etanidazole significantly enhanced host toxicity of high-dose ICE. Effective modulatory doses of etanidazole could not be given with acceptable toxicity using this schedule.
Biodosimetry estimate for high-LET irradiation.
Wang, Z Z; Li, W J; Zhi, D J; Jing, X G; Wei, W; Gao, Q X; Liu, B
2007-08-01
The purpose of this paper is to prepare for an easy and reliable biodosimeter protocol for radiation accidents involving high-linear energy transfer (LET) exposure. Human peripheral blood lymphocytes were irradiated using carbon ions (LET: 34.6 keV microm(-1)), and the chromosome aberrations induced were analyzed using both a conventional colcemid block method and a calyculin A induced premature chromosome condensation (PCC) method. At a lower dose range (0-4 Gy), the measured dicentric (dics) and centric ring chromosomes (cRings) provided reasonable dose information. At higher doses (8 Gy), however, the frequency of dics and cRings was not suitable for dose estimation. Instead, we found that the number of Giemsa-stained drug-induced G2 prematurely condensed chromosomes (G2-PCC) can be used for dose estimation, since the total chromosome number (including fragments) was linearly correlated with radiation dose (r = 0.99). The ratio of the longest and the shortest chromosome length of the drug-induced G2-PCCs increased with radiation dose in a linear-quadratic manner (r = 0.96), which indicates that this ratio can also be used to estimate radiation doses. Obviously, it is easier to establish the dose response curve using the PCC technique than using the conventional metaphase chromosome method. It is assumed that combining the ratio of the longest and the shortest chromosome length with analysis of the total chromosome number might be a valuable tool for rapid and precise dose estimation for victims of radiation accidents.
Older adults and high-risk medication administration in the emergency department.
Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J
2017-01-01
Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated ("High doses" were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; "very high doses" were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65-69, 70-74, 75-79, 80-84, and ≥85 years), gender, and hospital. There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65-69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56-11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69-18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26-1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07-2.16). Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65-69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted.
Dosimetric evaluation of total marrow irradiation using 2 different planning systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nalichowski, Adrian, E-mail: nalichoa@karmanos.org; Eagle, Don G.; Burmeister, Jay
This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using themore » Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.« less
Ruitenberg, Marc J; Wells, Julia; Bartlett, Perry F; Harvey, Alan R; Vukovic, Jana
2017-06-01
Birth of new neurons in the hippocampus persists in the brain of adult mammals and critically underpins optimal learning and memory. The process of adult neurogenesis is significantly reduced following brain irradiation and this correlates with impaired cognitive function. In this study, we aimed to compare the long-term effects of two environmental paradigms (i.e. enriched environment and exercise) on adult neurogenesis following high-dose (10Gy) total body irradiation. When housed in standard (sedentary) conditions, irradiated mice revealed a long-lasting (up to 4 months) deficit in neurogenesis in the granule cell layer of the dentate gyrus, the region that harbors the neurogenic niche. This depressive effect of total body irradiation on adult neurogenesis was partially alleviated by exposure to enriched environment but not voluntary exercise, where mice were single-housed with unlimited access to a running wheel. Exposure to voluntary exercise, but not enriched environment, did lead to significant increases in microglia density in the granule cell layer of the hippocampus; our study shows that these changes result from local microglia proliferation rather than recruitment and infiltration of circulating Cx 3 cr1 +/gfp blood monocytes that subsequently differentiate into microglia-like cells. In summary, latent neural precursor cells remain present in the neurogenic niche of the adult hippocampus up to 8 weeks following high-dose total body irradiation. Environmental enrichment can partially restore the adult neurogenic process in this part of the brain following high-dose irradiation, and this was found to be independent of blood monocyte-derived microglia presence. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Harrison, R M
2008-12-01
The increasing use of imaging for localization and verification in radiotherapy has raised issues concerning the justifiable doses to critical organs and tissues from concomitant exposures, particularly when extensive image-guided radiotherapy is indicated. Doses at positions remote from the target volume include components from high-energy leakage and scatter, as well as from concomitant imaging. In this paper, simulated prostate, breast and larynx treatments are used to compare doses from both high-energy and concomitant exposures as a function of distance from the target volume. It is suggested that the fraction, R, of the total dose at any point within the patient that is attributable to concomitant exposures may be a useful aid in their justification. R is small within the target volume and at large distances from it. However, there is a critical region immediately adjacent to the planning target volume where the dose from concomitant imaging combines with leakage and scatter to give values of R that approach 0.5 in the examples given here. This is noteworthy because the regions just outside the target volume will receive total doses in the order of 1 Gy, where commensurately high risk factors may not be substantially reduced because of cell kill. Other studies have identified these regions as sites of second cancers. The justification of an imaging regimen might therefore usefully take into account the maximum value of R encountered from the combination of imaging and radiotherapy for particular treatment sites.
Al-Bachir, Mahfouz
2017-01-01
Microbial contamination levels and corresponding sensitivities to gamma rays (GR) and elec- tron beam (EB) irradiation were tested in chamomile (Chamomile recutta L.). Chamomile powders were treated with 10 and 20 kGy by GR and EB, respectively. Microbiological and chemical analyses were performed on controls and treated samples immediately after irradiation, and after 12 months of storage. The control samples of chamomile exhibited rather high microbiological contamination, exceeding the levels of 4 log10 CFU g-1 (CFU - colony forming units) reported by national and international authorities as the maximum permissible total count level. Irradiation with GR and EB was found to cause a reduction in microbial contamination proportionate to the dose delivered. The sterilizing effect of EB on microorganisms was higher than the GR one. A dose of 10 kGy of GR and EB significantly (p < 0.05) reduced the total bacte- rial, total coliform and total fungal contamination. A dose of 20 kGy of GR significantly (p < 0.05) reduced the total bacterial and total fungal contamination, while a 20 kGy dose of EB reduced the initial bacterial, total coliform and total fungal contamination to below detection level when the analysis was carried out im- mediately after irradiation treatment or after 12 months of storage. The comparative study demonstrated that electron beam was more effective for decontamination of chamomile powder than gamma irradiation.
Karbalay-Doust, S; Noorafshan, A
2011-01-01
Metronidazole (MTZ) is used as an antiparasitic drug. Curcumin is considered as anti-oxidant and anti-inflammatory agent. The ameliorative effects of curcumin on MTZ induced toxicity on mice spermatozoon tail length, count, motility and testosterone level were investigated. MTZ was administered in 500 and 165 (high and therapeutic doses) mg/kg/day, with and without curcumin (100 mg/kg/day). After 16 days the above parameters were assessed. Spermatozoon count and motility and serum testosterone level MTZ-treated (500 and 165) mice were reduced. In the mice treated with MTZ+curcumin these parameters decreased but in a lesser extent than the MTZ-treated animals. Mid-piece and total lengths of the spermatozoon tail in control animals were 31.6 ± 9.0 μm and 100.3 ± 15.0 μm and in the mice treated with high doses (500) of MTZ were reduced. The mid-piece and total spermatozoon tail length has been decreased in a lesser extent in the mice treated with high dose MTZ+curcumin than the mice treated with high dose MTZ (p<0.01). But the length was not changed in animals treated with therapeutic dose of MTZ. It means curcumin treated animals had ~52% and ~39% average increase in mid-piece and total lengths in comparison with the MTZ-treated (500) animals. Stereological estimation of the sperm tail length, including sampling of spermatozoa and also counting of the intersections of their tails with the stereological grids was a rapid technique and took only 5-10 minutes. It can be concluded that curcumin has an ameliorative effect on the spermatozoon, testosterone level and tail length in MTZ-treated mice.
NASA Technical Reports Server (NTRS)
Quilligan, Gerard T.; Aslam, Shahid; Lakew, Brook; DuMonthier, Jeffery J.; Katz, Richard B.; Kleyner, Igor
2014-01-01
Radiation hardened by design (RHBD) techniques allow commercial CMOS circuits to operate in high total ionizing dose and particle fluence environments. Our radiation hard multi-channel digitizer (MCD) ASIC (Figure 1) is a versatile analog system on a chip (SoC) fabricated in 180nm CMOS. It provides 18 chopper stabilized amplifier channels, a 16- bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The MCD was evaluated at Goddard Space Flight Center and Texas A&M University's radiation effects facilities and found to be immune to single event latchup (SEL) and total ionizing dose (TID) at 174 MeV-cm(exp 2)/mg and 50 Mrad (Si) respectively.
Chemo-physical properties of renal capsules under ultraviolet-c exposure
NASA Astrophysics Data System (ADS)
Baghapour, Sh.; Parvin, P.; Reyhani, A.; Mortazavi, S. Z.; Mokhtari, S.; Amjadi, A.
2014-08-01
The renal capsule tissue of lamb was irradiated with ultraviolet-C light and the treated samples were analyzed by uniaxial tensile test, dynamic mechanical analysis, attenuated total reflectance Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and contact angle measurements. It was shown that the skin cross-linking is dominant in low doses in accordance with the contact angle assessment. Conversely, the strong bulk degradation takes place at high doses. Similarly, the bulk cross-linking affects the mechanical tests as to enhance the stiffness at low doses, whereas strong degradation occurs at high doses that mainly arises from the strong bulk chain scission.
Small Total Dose Measurement System for SOHLA-1 and SDS-1
NASA Astrophysics Data System (ADS)
Kimoto, Yugo; Satoh, Yohei; Tachihara, Hiroshi
The Japanese Aerospace Exploration Agency (JAXA) uses monitors on board satellites to measure and record in-flight data about ionization effects in space. A compact, total-dose measurement system for small satellites—Space-Oriented Higashiosaka Leading Association -1 (SOHLA-1) and Small Demonstration-Satellite -1 (SDS-1)—was developed based on a prior system for measuring total ionizing dose effects. Especially, the sensor for SDS-1 is much smaller than the sensor for SOHLA-1. The sensor for SDS-1 is 8 mm wide × 3 mm high × 19 mm long and weighs approximately 4 g with 500 mm with its wire harness. An 8-pin Lead less Chip Carrier (LCC) RADFET and temperature sensor are arranged on it. Seven sensors are mounted on some components inside the SDS-1. The sensor for SOHLA-1 is a 14-pin Dual Inline Package (DIP) type RADFET. The four sensors, which have RADFET on a printed board covered with an aluminum chassis, are mounted both inside and outside the satellite. This report presents small total dose measurement systems and ground irradiation test results for two small satellites.
Lhermie, Guillaume; Dupouy, Véronique; El Garch, Farid; Ravinet, Nadine; Toutain, Pierre-Louis; Bousquet-Mélou, Alain; Seegers, Henri; Assié, Sébastien
2017-03-01
In the context of requested decrease of antimicrobial use in veterinary medicine, our objective was to assess the impact of two doses of marbofloxacin administered on young bulls (YBs) and veal calves (VCs) treated for bovine respiratory disease, on the total population of Enterobacteriaceae in gut flora and on the emergence of resistant Enterobacteriaceae. In two independent experiments, 48 YBs from 6 commercial farms and 33 VCs previously colostrum deprived and exposed to cefquinome were randomly assigned to one of the three groups LOW, HIGH, and Control. In LOW and HIGH groups, animals received a single injection of, respectively, 2 and 10 mg/kg marbofloxacin. Feces were sampled before treatment, and at several times after treatment. Total and resistant Enterobacteriaceae enumerating were performed by plating dilutions of fecal samples on MacConkey agar plates that were supplemented or not with quinolone. In YBs, marbofloxacin treatment was associated with a transient decrease in total Enterobacteriaceae count between day (D)1 and D3 after treatment. Total Enterobacteriaceae count returned to baseline between D5 and D7 in all groups. None of the 48 YBs harbored marbofloxacin-resistant Enterobacteriaceae before treatment. After treatment, 1 out of 20 YBs from the Control group and 1 out of 14 YBs from the HIGH group exhibited marbofloxacin-resistant Enterobacteriaceae. In VCs, the rate of fluoroquinolone-resistant Enterobacteriaceae significantly increased after low and high doses of marbofloxacin treatment. However, the effect was similar for the two doses, which was probably related to the high level of resistant Enterobacteriaceae exhibited before treatment. Our results suggest that a single treatment with 2 or 10 mg/kg marbofloxacin exerts a moderate selective pressure on commensal Enterobacteriaceae in YBs and in VCs. A fivefold decrease of marbofloxacin regimen did not affect the selection of resistances among commensal bacteria.
Müller, Christian A; Geisel, Olga; Pelz, Patricia; Higl, Verena; Krüger, Josephine; Stickel, Anna; Beck, Anne; Wernecke, Klaus-Dieter; Hellweg, Rainer; Heinz, Andreas
2015-08-01
Previous randomized, placebo-controlled trials (RCTs) assessing the efficacy of the selective γ-aminobutyric acid (GABA)-B receptor agonist baclofen in the treatment of alcohol dependence have reported divergent results, possibly related to the low to medium dosages of baclofen used in these studies (30-80mg/d). Based on preclinical observations of a dose-dependent effect and positive case reports in alcohol-dependent patients, the present RCT aimed to assess the efficacy and safety of individually titrated high-dose baclofen for the treatment of alcohol dependence. Out of 93 alcohol-dependent patients initially screened, 56 were randomly assigned to a double-blind treatment with individually titrated baclofen or placebo using dosages of 30-270mg/d. The multiple primary outcome measures were (1) total abstinence and (2) cumulative abstinence duration during a 12-week high-dose phase. More patients of the baclofen group maintained total abstinence during the high-dose phase than those receiving placebo (15/22, 68.2% vs. 5/21, 23.8%, p=0.014). Cumulative abstinence duration was significantly higher in patients given baclofen compared to patients of the placebo group (mean 67.8 (SD 30) vs. 51.8 (SD 29.6) days, p=0.047). No drug-related serious adverse events were observed during the trial. Individually titrated high-dose baclofen effectively supported alcohol-dependent patients in maintaining alcohol abstinence and showed a high tolerability, even in the event of relapse. These results provide further evidence for the potential of baclofen, thereby possibly extending the current pharmacological treatment options in alcohol dependence. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.
High level gamma radiation effects on Cernox™ cryogenic temperature sensors
NASA Astrophysics Data System (ADS)
Courts, S. S.
2017-12-01
Cryogenic temperature sensors are used in high energy particle colliders to monitor the temperatures of superconducting magnets, superconducting RF cavities, and cryogen infrastructure. While not intentional, these components are irradiated by leakage radiation during operation of the collider. A common type of cryogenic thermometer used in these applications is the Cernox™ resistance thermometer (CxRT) manufactured by Lake Shore Cryotronics, Inc. This work examines the radiation-induced calibration offsets on CxRT models CX-1050-SD-HT and CX-1080-SD-HT resulting from exposure to very high levels of gamma radiation. Samples from two different wafers of each of the two models tested were subjected to a gamma radiation dose ranging from 10 kGy to 5 MGy. Data were analysed in terms of the temperature-equivalent resistance change between pre- and post-irradiation calibrations. The data show that the resistance of these devices decreased following irradiation resulting in positive temperature offsets across the 1.4 K to 330 K temperature range. Variations in response were observed between wafers of the same CxRT model. Overall, the offsets increased with increasing temperature and increasing gamma radiation dose. At 1.8 K, the average offset increased from 0 mK to +13 mK as total dose increased from 10 kGy to 5 MGy. At 4.2 K, the average offset increased from +4 mK to +33 mK as total dose increased from 10 kGy to 5 MGy. Equivalent temperature offset data are presented over the 1.4 K to 330 K temperature range by CxRT model, wafer, and total gamma dose.
Glyburide transport across the human placenta.
Schwartz, Rachelle A; Rosenn, Barak; Aleksa, Katarina; Koren, Gideon
2015-03-01
To estimate the magnitude of transplacental transfer of glyburide in women with gestational diabetes mellitus (GDM). A prospective, observational study was conducted on women with GDM on glyburide therapy. On delivery admission, the glyburide dose and time of last dose were recorded. Immediately postdelivery, maternal and umbilical venous blood samples were obtained and the concentrations of glyburide were determined by high-performance liquid chromatography-mass spectrometry with a limit of detection of 0.25 ng/mL. Nineteen patient dyads were analyzed. The mean total daily maternal glyburide dose was 6.6±6.3 mg per day and the mean time between last dose and sampling was 13.3±6.5 hours. The mean maternal serum glyburide level at birth was 15.4±20.8 ng/mL, whereas the mean umbilical glyburide level was 7.5±8.2 ng/mL, which showed a statistical correlation (r=0.72, P<.01). There were statistically significant relationships between total maternal glyburide dose (1.25-20 mg per day) and maternal glyburide levels (0.93-70.71 ng/mL; r=0.46, P≤.01) and between total maternal glyburide dose and umbilical glyburide levels (0.95-32.41 ng/mL; r=0.43, P≤.01) However, we observed wide variability in maternal and umbilical glyburide levels at both extremes of the total glyburide dose. Seventy-nine percent of cord samples (15/19) had glyburide levels less than 10 ng/mL (the limit of detection reported in earlier studies) and 37% (7/19) were higher than the corresponding maternal samples. Transplacental transfer of glyburide is highly variable among patients, corroborating ex vivo placental perfusion studies showing a transport-mediated glyburide efflux from the fetal to the maternal circulation. In most neonates (79%), glyburide levels were below 10 ng/mL. III.
NASA Astrophysics Data System (ADS)
Zhao, Qian; Sun, Yeqing; Wang, Wei
2016-07-01
Highly ionizing radiation (HZE) in space is considered as a main factor causing biological effects on plant seeds. To investigate the different effects on genome-wide gene expression of low-dose and high-dose ion radiation, we carried out ground-base carbon particle HZE experiments with different cumulative doses (0Gy, 0.2Gy, 2Gy) to rice seeds and then performed comparative transcriptome analysis of the rice seedlings. We identified a total of 2551 and 1464 differentially expressed genes (DEGs) in low-dose and high-dose radiation groups, respectively. Gene ontology analyses indicated that low-dose and high-dose ion radiation both led to multiple physiological and biochemical activities changes in rice. By Gene Ontology analyses, the results showed that only one process-oxidation reduction process was enriched in the biological process category after high-dose ion radiation, while more processes such as response to biotic stimulus, heme binding, tetrapyrrole binding, oxidoreductase activity, catalytic activity and oxidoreductase activity were significantly enriched after low-dose ion radiation. The results indicated that the rice plants only focused on the process of oxidation reduction to response to high-dose ion radiation, whereas it was a coordination of multiple biological processes to response to low-dose ion radiation. To elucidate the transcriptional regulation of radiation stress-responsive genes, we identified several DEGs-encoding TFs. AP2/EREBP, bHLH, C2H2, MYB and WRKY TF families were altered significantly in response to ion radiation. Mapman analysis speculated that the biological effects on rice seedlings caused by the radiation stress might share similar mechanisms with the biotic stress. Our findings highlight important alterations in the expression of radiation response genes, metabolic pathways, and TF-encoding genes in rice seedlings exposed to low-dose and high-dose ion radiation.
The financial impact of increasing home-based high dose haemodialysis and peritoneal dialysis.
Liu, Frank Xiaoqing; Treharne, Catrin; Culleton, Bruce; Crowe, Lydia; Arici, Murat
2014-10-02
Evidence suggests that high dose haemodialysis (HD) may be associated with better health outcomes and even cost savings (if conducted at home) versus conventional in-centre HD (ICHD). Home-based regimens such as peritoneal dialysis (PD) are also associated with significant cost reductions and are more convenient for patients. However, the financial impact of increasing the use of high dose HD at home with an increased tariff is uncertain. A budget impact analysis was performed to investigate the financial impact of increasing the proportion of patients receiving home-based dialysis modalities from the perspective of the England National Health Service (NHS) payer. A Markov model was constructed to investigate the 5 year budget impact of increasing the proportion of dialysis patients receiving home-based dialysis, including both high dose HD at home and PD, under the current reimbursement tariff and a hypothetically increased tariff for home HD (£575/week). Five scenarios were compared with the current England dialysis modality distribution (prevalent patients, 14.1% PD, 82.0% ICHD, 3.9% conventional home HD; incident patients, 22.9% PD, 77.1% ICHD) with all increases coming from the ICHD population. Under the current tariff of £456/week, increasing the proportion of dialysis patients receiving high dose HD at home resulted in a saving of £19.6 million. Conducting high dose HD at home under a hypothetical tariff of £575/week was associated with a budget increase (£19.9 million). The costs of high dose HD at home were totally offset by increasing the usage of PD to 20-25%, generating savings of £40.0 million - £94.5 million over 5 years under the increased tariff. Conversely, having all patients treated in-centre resulted in a £172.6 million increase in dialysis costs over 5 years. This analysis shows that performing high dose HD at home could allow the UK healthcare system to capture the clinical and humanistic benefits associated with this therapy while limiting the impact on the dialysis budget. Increasing the usage of PD to 20-25%, the levels observed in 2005-2008, will totally offset the additional costs and generate further savings.
Yu, Il Je; Song, Kyung Seuk; Chang, Hee Kyung; Han, Jeong Hee; Chung, Yong Hyun; Han, Kuy Tae; Chung, Kyu Hyuck; Chung, Ho Keun
2003-08-28
Welders with radiographic pneumoconiosis abnormalities have exhibited a gradual clearing of the X-ray identified effects following removal from exposure. In some cases, the pulmonary fibrosis associated with welding fumes appears in a more severe form in welders. Accordingly, to investigate the disease and recovery process of pneumoconiosis induced by welding-fume exposure, rats were exposed to welding fumes with concentrations of 63.6+/-4.1 mg/m(3) (low dose) and 107.1+/-6.3 mg/m(3) (high dose) of total suspended particulate for 2 h per day in an inhalation chamber for a total of 2 h or 15, 30, 60 or 90 days. Thereafter, the rats were no longer exposed and allowed to recover from the welding fume-induced lung fibrosis for 90 days. When compared to the unexposed control group, the lung weights significantly increased in both the low- and high-dose rats from day 15 to 90. A histopathological examination combined with fibrosis-specific staining revealed that the lungs from the low-dose rats did not exhibit any significant progressive fibrotic changes. Whereas, the lungs from the high-dose rats exhibited early delicate fibrosis from day 15, which progressed into the perivascular and peribronchiolar regions by day 30. Interstitial fibrosis appeared at day 60 and became prominent by day 90, along with the additional appearance of pleural fibrosis. Recovery, evaluated based on the body and lung weights and a histopathological examination, was observed in both the high and low-dose rats that were exposed up to 30 days. The rats exposed for 60-90 days at the low dose also recovered from the fibrosis, yet the rats exposed for 60-90 days at the high dose did not fully recover. Consequently, recovery from pneumoconiosis induced by welding-fume exposure was observed when the degree of exposure was short-term and moderate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsons, J.T.; Bova, F.J.; Million, R.R.
1994-11-15
To investigate the risk of radiation-induced optic neuropathy according to total radiotherapy dose and fraction size, based on both retrospective and prospectively collected data. Between October 1964 and May 1989, 215 optic nerves in 131 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 21 years). The clinical end point was visual acuity of 20/100 or worse as a result of optic nerve injury. Anterior ischemic optic neuropathy developed in five nerves (at mean and median times of 32 andmore » 30 months, respectively, and a range of 2-4 years). Retrobulbar optic neuropathy developed in 12 nerves (at mean and median times of 47 and 28 months, respectively, and a range of 1-14 years). No injuries were observed in 106 optic nerves that received a total dose of <59 Gy. Among nerves that received doses of {ge} 60 Gy, the dose per fraction was more important than the total dose in producing optic neuropathy. The 15-year actuarial risk of optic compared with 47% when given in fraction sizes {ge}1.9 Gy. The data also suggest an increased risk of optic nerve injury with increasing age. As there is no effective treatment of radiation-induced optic neuropathy, efforts should be directed at its prevention by minimizing the total dose, paying attention to the dose per fraction to the nerve, and using reduced field techniques where appropriate to limit the volume of tissues that receive high-dose irradiation. 32 refs., 5 figs., 5 tabs.« less
Kiernan, Michael S; Stevens, Susanna R; Tang, W H Wilson; Butler, Javed; Anstrom, Kevin J; Birati, Edo Y; Grodin, Justin L; Gupta, Divya; Margulies, Kenneth B; LaRue, Shane; Dávila-Román, Victor G; Hernandez, Adrian F; de Las Fuentes, Lisa
2018-03-01
Poor response to loop diuretic therapy is a marker of risk during heart failure hospitalization. We sought to describe baseline determinants of diuretic response and to further explore the relationship between this response and clinical outcomes. Patient data from the National Heart, Lung, and Blood Institute Heart Failure Network ROSE-AHF and CARRESS-HF clinical trials were analyzed to determine baseline determinants of diuretic response. Diuretic efficiency (DE) was defined as total 72-hour fluid output per total equivalent loop diuretic dose. Data from DOSE-AHF was then used to determine if these predictors of DE correlated with response to a high- versus low-dose diuretic strategy. At 72 hours, the high-DE group had median fluid output of 9071 ml (interquartile range: 7240-11775) with median furosemide dose of 320 mg (220-480) compared with 8030 ml (6300-9915) and 840 mg (600-1215) respectively for the low DE group. Cystatin C was independently associated with DE (odds ratio 0.36 per 1mg/L increase; 95% confidence interval: 0.24-0.56; P < 0.001). Independently from baseline characteristics, reduced fluid output, weight loss and DE were each associated with increased 60 day mortality. Among patients with estimated glomerular filtration rate below the median, those randomized to a high-dose strategy had improved symptoms compared with those randomized to a low-dose strategy. Elevated baseline cystatin C, as a biomarker of renal dysfunction, is associated with reduced diuretic response during heart failure hospitalization. Higher loop diuretic doses are required for therapeutic decongestion in patients with renal insufficiency. Poor response identifies a high-risk population. Copyright © 2018 Elsevier Inc. All rights reserved.
Small total dose measurement system for SDS-1
NASA Astrophysics Data System (ADS)
Kimoto, Yugo; Satoh, Yohei; Tachihara, Hiroshi
2009-11-01
The Japanese Aerospace Exploration Agency (JAXA) uses monitors on board satellites to measure and record in-flight data on ionization effects in space. A compact, total dose measurement system for the small satellite (SDS-1) was developed based on the previous system for measuring total ionizing dose effects. Especially, the sensor for SDS-1 is quite smaller than the sensor for SOHLA-1, which is presented in the last year. The sensor is 8 mm wide×3 mm high×19 mm long and weighs approximately 4 g with 500 mm its wire harness. Eight pin LCC RADFET and temperature sensor are arranged on it. Seven sensors are arranged on some components inside the SDS-1. One of the sensors is arranged on a printed board in advanced microprocessing in-ORBIT experiment equipment (AMI). The AMI demonstrate 320 MIPS microprocessor and DC-DC converter for space. The absorbed dose at the points where the sensors are arranged was evaluated before flight and will be compared with resulting flight data.
NASA Astrophysics Data System (ADS)
Veigel, Cornelia; Hartmann, Günther H.; Fritz, Peter; Debus, Jürgen; Weber, Klaus-Josef
2017-02-01
Afterloading brachytherapy is conducted by the stepwise movement of a radioactive source through surgically implanted applicator tubes where at predefined dwell positions calculated dwell times optimize spatial dose delivery with respect to a planned dose level. The temporal exposure pattern exhibits drastic fluctuations in dose rate at a given coordinate and within a single treatment session because of the discontinuous and repeated source movement into the target volume. This could potentially affect biological response. Therefore, mammalian cells were exposed as monolayers to a high dose rate 192Ir source by utilizing a dedicated irradiation device where the distance between a planar array of radioactive source positions and the plane of the cell monolayer could be varied from 2.5 mm to 40 mm, thus varying dose rate pattern for any chosen total dose. The Gammamed IIi afterloading system equipped with a nominal 370 GBq (10 Ci) 192-Ir source was used to irradiate V79 Chinese hamster lung fibroblasts from both confluent and from exponential growth phase with dose up to 12 Gy (at room temperature, total exposure not exceeding 1 h). For comparison, V79 cells were also exposed to 6 MV x-rays from a clinical linear accelerator (dose rate of 2.5 Gy min-1). As biological endpoint, cell survival was determined by standard colony forming assay. Dose measurements were conducted with a diamond detector (sensitive area 7.3 mm2), calibrated by means of 60Co radiation. Additionally, dose delivery was simulated by Monte Carlo calculations using the EGSnrc code system. The calculated secondary electron fluence spectra at the cell location did not indicate a significant change of radiation quality (i.e. higher linear energy transfer) at the lower distances. Clonogenic cell survival curves obtained after brachytherapy exhibited an altered biological response compared to x-rays which was characterized by a significant reduction of the survival curve shoulder when dose rate fluctuations were high. Therefore, also for the time scale of the present investigation, cellular effects of radiation are not invariant to the temporal pattern in dose rate. We propose that with high dose rate variation the cells activate less efficiently their DNA damage response than after continuous irradiation.
Maier, R F; Obladen, M; Kattner, E; Natzschka, J; Messer, J; Regazzoni, B M; Speer, C P; Fellman, V; Grauel, E L; Groneck, P; Wagner, M; Moriette, G; Salle, B L; Verellen, G; Scigalla, P
1998-05-01
To investigate whether a weekly 1500 IU/kg dose of recombinant human erythropoietin (rhEPO) is more effective than a dose of 750 IU/kg/week in preventing anemia and reducing the transfusion need in infants with birth weights less than 1000 gm. In a randomized, double-blind, multicenter trial, 184 infants with birth weights between 500 and 999 gm were treated with either rhEPO 750 (low-dose group) or 1500 IU/kg/week (high-dose group) from day 3 of life until 37 weeks' corrected age. Thirty-two percent of the infants in each group did not receive any transfusion during the treatment period. The total volume of erythrocytes received was similar in each group. The success rate, defined as no transfusion needed and hematocrit value 0.30 L/L or greater, was 27.6% in the low-dose and 29.5% in the high-dose group (p = 0.96). Doubling the rhEPO dose of 750 IU/kg/week is not indicated in infants with birth weights less than 1000 gm.
Chronic toxicity of a mixture of chlorinated alkanes and alkenes in ICR mice.
Wang, Fun-In; Kuo, Min-Liang; Shun, Chia-Tung; Ma, Yee-Chung; Wang, Jung-Der; Ueng, Tzuu-Huei
2002-02-01
The aim of this study was to determine the chronic toxicity of a mixture of chlorinated alkanes and alkenes (CA) consisting of chloroform, 1,1-dichloroethane, 1,1-dichloroethylene, 1,1,1-trichloroethane, trichloroethylene, and tetrachloroethylene. These chlorinated organic solvents were present in the underground water near an electronic appliances manufactory in Taoyuan, Taiwan. Male and female weanling ICR mice were treated with low-, medium-, and high-dose CA mixtures in drinking water for 16 and 18 mo, respectively. A significant number of male mice treated with the high-dose CA mixture developed tail alopecia and deformation, which was not prominent in CA-treated female mice. Medium- and high-dose CA mixtures induced marginal increases of liver and lung weights, blood urea nitrogen, and serum creatinine levels in male mice. In female mice, the high-dose CA mixture increased liver, kidney, and uterus and ovary total weights, without affecting serum biochemistry parameters. CA mixtures had no effects on the total glutathione content or the level of glutathione S-transferase activity in the livers and kid- neys of male and female mice. Treatments with CA mixtures produced a trend of increasing frequency of hepatocelluar neoplasms in male mice, compared to male and female controls and CA-treated female mice. The high-dose CA mixture induced a significantly higher incidence of mammary adenocarcinoma in female mice. The calculated odds ratios of mammary adenocarcinoma in female mice induced by low-, medium-, and high-dose CA mixtures were 1.14, 1.37, and 3.53 times that of the controls, respectively. The low-dose CA mixture induced a higher incidence of cysts and inflammation in and around the ovaries. This study has demonstrated that the CA mixture is a potential carcinogen to male and female mice. These animal toxicology data may be important in assessing the health effects of individuals exposed to the CA mixture.
A Pilot Study: Cardiac Parameters in Children Receiving New-Generation Antidepressants.
Uchida, Mai; Spencer, Andrea E; Kenworthy, Tara; Chan, James; Fitzgerald, Maura; Rosales, Ana Maria; Kagan, Elana; Saunders, Alexandra; Biederman, Joseph
2017-06-01
Because of concerns about potential associations between high doses of citalopram and QTc prolongation in adults, this study examined whether such associations are operant in children. We hypothesized that therapeutic doses of nontricyclic antidepressant medications (non-TCAs) prescribed to children would be cardiovascularly safe. The sample consisted of 49 psychiatrically referred children and adolescents 6 to 17 years old of both sexes treated with a non-TCA (citalopram, escitalopram, fluoxetine, paroxetine, sertraline, bupropion, duloxetine, venlafaxine, mirtazapine). To standardize the doses of different antidepressants, we converted doses of individual medicines into "citalopram equivalent doses" (CEDs) based on dosing recommendation for individual antidepressants. Correlation analysis was carried out to compare the continuous and weight-based CED to variables of interest. A QTc grouping was defined as normal, borderline, or abnormal, and CED was compared across QTc groupings using linear regression. An antidepressant dosage group was defined as low or high dose, and a t test compared variables of interest across dosage groups. No significant associations were found between total or weight-corrected CEDs of any antidepressant examined and QTc or any other electrocardiogram or blood pressure parameters. In patients taking citalopram or escitalopram, a significant correlation was found between PR interval and total daily dose, which disappeared when weight-based doses were used or when corrected by age. Although limited by a relatively small sample size, these results suggest that therapeutic doses of non-TCA antidepressants when used in children do not seem to be associated with prolonged QTc interval or other adverse cardiovascular effects.
Dosimetry for radiobiological studies of the human hematopoietic system
NASA Technical Reports Server (NTRS)
Beck, W. L.; Stokes, T. R.; Lushbaugh, C. C.
1972-01-01
A system for estimating individual bone marrow doses in therapeutic radiation exposures of leukemia patients was studied. These measurements are used to make dose response correlations and to study the effect of dose protraction on peripheral blood cell levels. Three irradiators designed to produce a uniform field of high energy gamma radiation for total body exposures of large animals and man are also used for radiobiological studies.
Sturgeon, Kathleen; Digiovanni, Laura; Good, Jerene; Salvatore, Domenick; Fenderson, Desiré; Domchek, Susan; Stopfer, Jill; Galantino, Mary Lou; Bryan, Cathy; Hwang, Wei-Ting; Schmitz, Kathryn
2016-08-01
Dysregulation of adipokines, such as adiponectin and leptin, is associated with a variety of chronic diseases, including cancer. Physical activity protects against breast cancer and one of the mechanisms which may underlie this association is exercise-induced changes in adipokine levels. The WISER Sister Trial was a three-armed randomized controlled trial in premenopausal women (n = 137) with an elevated risk for breast cancer. A 5-menstrual-cycle-long dosed aerobic exercise intervention compared low-dose exercise (150 min/wk; n = 44) or high-dose exercise (300 min/wk; n = 48) with a control group asked to maintain usual activity levels (n = 45). Exercise intensity progressed to and was maintained at 70% to 80% of age predicted heart rate max. Body composition and adipokine levels were measured at baseline and follow-up. We observed significant linear trends for increased fitness capacity (Δ%: -2.0% control, 10.1% low dose, 13.1% high dose), decreased fat tissue-to-total tissue mass (Δ%: 0.7% control, -2.9% low dose, -3.7% high dose), increased body fat adjusted adiponectin (Δ%: -0.6% control, 0.6% low dose, 0.9% high dose), and decreased body fat adjusted leptin (Δ%: 0.7% control, -8.2% low dose, -10.2% high dose). In this randomized clinical trial of premenopausal women at risk for breast cancer, we demonstrate a dose-response effect of exercise on adiponectin and leptin and that dose response is dependent on changes in body fat. Improved adipokine levels, achieved by aerobic exercise training-induced decreases in body fat, may decrease breast cancer risk for high-risk premenopausal women. Cancer Epidemiol Biomarkers Prev; 25(8); 1195-200. ©2016 AACR. ©2016 American Association for Cancer Research.
Bello-Bello, Jericó J; Chavez-Santoscoy, Rocío A; Lecona-Guzmán, Carlos A; Bogdanchikova, Nina; Salinas-Ruíz, Josafhat; Gómez-Merino, Fernando Carlos; Pestryakov, Alexey
2017-01-01
Hormesis is considered a dose-response phenomenon characterized by growth stimulation at low doses and inhibition at high doses. The hormetic response by silver nanoparticles (AgNPs) on in vitro multiplication of sugarcane was evaluated using a temporary immersion system. Sugarcane shoots were used as explants cultured in Murashige and Skoog medium with AgNPs at concentrations of 0, 25, 50, 100, and 200 mg/L. Shoot multiplication rate and length were used to determine hormetic response. Total content of phenolic compounds of sugarcane, mineral nutrition, and reactive oxygen species (ROS) was determined. Results were presented as a dose-response curve. Stimulation phase growth was observed at 50 mg/L AgNPs, whereas inhibition phase was detected at 200 mg/L AgNPs. Mineral nutrient analysis showed changes in macronutrient and micronutrient contents due to the effect of AgNPs. Moreover, AgNPs induced ROS production and increased total phenolic content, with a dose-dependent effect. Results suggested that the production of ROS and mineral nutrition are key mechanisms of AgNP-induced hormesis and that phenolic accumulation was obtained as a response of the plant to stress produced by high doses of AgNPs. Therefore, small doses of AgNPs in the culture medium could be an efficient strategy for commercial micropropagation.
2012-01-01
The objective of the study is a comparative evaluation of flavone isolated from Mucuna pruriens and coumarin isolated from Ionidium suffruticosum was assessed for the hypolipidemic activity in rats fed with high fat diet. The acute toxicity study was found that flavone (M.pruriens) and coumarin (I.suffruticosum) are safe up to 100mg/kg, so one tenth of this dose (10mg/kg) was consider as a evaluation dose. High fat diet group of rats showed significant (p<0.001) elevation in plasma total and LDL-cholesterol, triglycerides and phospholipids. Administration of flavone (M. pruriens) and coumarin isolated from (I.suffruticosum) at the dose of 10mg/kg b.wt/day along with high fat diet significantly (p<0.001) prevented the rise in the plasma total and LDL-cholesterol, triglycerides and phospholipids than that of other extracts. However, treatment of coumarin isolated from (I.suffruticosum) had showed more cardio protective effect against hyperlipidemia than that of flavone (M.pruriens). PMID:23031584
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greco, Carlo; Zelefsky, Michael J., E-mail: zelefskm@mskcc.or; Lovelock, Michael
2011-03-15
Purpose: To report tumor local control after treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) to extracranial metastatic sites. Methods and Materials: A total of 126 metastases in 103 patients were treated with SD-IGRT to prescription doses of 18-24 Gy (median, 24 Gy) between 2004 and 2007. Results: The overall actuarial local relapse-free survival (LRFS) rate was 64% at a median follow-up of 18 months (range, 2-45 months). The median time to failure was 9.6 months (range, 1-23 months). On univariate analysis, LRFS was significantly correlated with prescription dose (p = 0.029). Stratification by dose into high (23 to 24 Gy),more » intermediate (21 to 22 Gy), and low (18 to 20 Gy) dose levels revealed highly significant differences in LRFS between high (82%) and low doses (25%) (p < 0.0001). Overall, histology had no significant effect on LRFS (p = 0.16). Renal cell histology displayed a profound dose-response effect, with 80% LRFS at the high dose level (23 to 24 Gy) vs. 37% with low doses ({<=}22 Gy) (p = 0.04). However, for patients who received the high dose level, histology was not a statistically significant predictor of LRFS (p = 0.90). Target organ (bone vs. lymph node vs. soft tissues) (p = 0.5) and planning target volume size (p = 0.55) were not found to be associated with long-term LRFS probability. Multivariate Cox regression analysis confirmed prescription dose to be a significant predictor of LRFS (p = 0.003). Conclusion: High-dose SD-IGRT is a noninvasive procedure resulting in high probability of local tumor control. Single-dose IGRT may be effectively used to locally control metastatic deposits regardless of histology and target organ, provided sufficiently high doses (> 22 Gy) of radiation are delivered.« less
Accelerated heavy particles and the lens. VII: The cataractogenic potential of 450 MeV/amu iron ions
NASA Technical Reports Server (NTRS)
Worgul, B. V.; Brenner, D. J.; Medvedovsky, C.; Merriam, G. R. Jr; Huang, Y.
1993-01-01
PURPOSE. To determine the cataractogenic potential dose of high velocity iron ions as a fixation of dose administered singly or fractionated. The dose is critical to risk assessment and to theories of radiation action and cataractogenesis. METHODS. Twenty-eight-day-old rats were examined by slit-lamp biomicroscopy on a weekly-bi-weekly basis for more than 2 yr after radiation exposure. For the acute exposure study doses of 1, 2, 5, 25, and 50 cGy were evaluated. The fractionated regimens involved total doses of 2, 25, and 50 cGy. The reference radiation consisted of 50, 100, 200, or 700 cGy of 250 kilovolt (peak) x-rays. RESULTS. In accordance with previous findings in the rat using 570 MeV/amu 40Ar ions, the relative biologic effectiveness increased rapidly with decreasing dose, reaching values as high as 100. Unlike 40Ar ions, fractionation of the 56Fe doses did not produce a consistent enhancement at any of the doses examined. CONCLUSIONS. The data support the previous findings of a high cataractogenic potential for high linear energy transfer (LET) radiation. The effectiveness for the production of cataracts increases with decreasing dose relative to x-rays and is independent of dose protraction. Although the present study did not reveal a consistent enhancement of effect when the ions were applied in fractions, the results are consistent with at least one theory of the inverse dose-rate effect observed for high-LET radiation.
Klimek, L; Uhlig, J; Mösges, R; Rettig, K; Pfaar, O
2014-01-01
Background Cluster immunotherapy represents an interesting alternative to conventional up-dosing schedules because it allows achieving the maintenance dose within a shorter time interval. In this study, the efficacy and safety of cluster immunotherapy with a high polymerized allergen extract of a grass/rye pollen mixture have been evaluated in a randomized, double-blind, placebo-controlled, multicenter study. Methods In total, 121 patients with allergic rhinoconjunctivitis due to grass pollen were randomized 1 : 1 to verum or placebo group. A short cluster up-dosing schedule of only 1 week was applied to achieve the maintenance dose which was administered monthly during the study period of 1 year. Total combined symptom and medication score (TCS) was defined as primary outcome parameter. Secondary outcome parameters were individual symptom and medication scores, ‘well days,’ global improvement as well as immunological effects and nasal allergen challenge. The safety profile was evaluated based on the European academy of allergy and clinical immunology grading system. Results Significant reduction in the verum compared to the placebo group (intention-to-treat, population, verum: n = 55; placebo: n = 47) was found regarding TCS (P = 0.005), rhinoconjunctivitis total symptom score (RTSS, P = 0.006), and total rescue medication score (TRMS, P = 0.002). Additionally, secondary outcomes such as ‘well days,’ nasal challenge results, and increase of specific IgG4 were in favor of the active treatment. All systemic adverse reactions (0.8% of all injections in the verum group) were of mild intensity. No severe reactions related to the study medication were observed. Conclusion Cluster immunotherapy with high polymerized grass pollen extracts resulted in significant clinical efficacy and has been shown to be a safe treatment for grass pollen-allergic patients. PMID:25130503
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hermansen, M; Bova, F; John, T St.
2015-06-15
Purpose To minimize the number of monitor units required to deliver a sphere packing stereotactic radiosurgery (SRS) plan by eliminating overlaps of individual beam projections. Methods An algorithm was written in C{sup ++} to calculate SRS treatment doses using sphere packing. Three fixed beams were used to approximate each arc in a typical SRS treatment plan. For cases involving multiple isocenters, at each gantry and table angle position beams directed to individual spheres overlap to produce regions of high dose, resulting in intensity modulated beams. These high dose regions were dampened by post-processing of the combined beam profile. The post-processmore » dampening involves removing the excess overlapping fluence from all but the highest contributing beam. The dampened beam profiles at each table and gantry angle position were then summed to produce the new total dose distribution. Results Delivery times for even the most complex multiple sphere plans can be reduced to consistent times of about 20 to 30 minutes. The total MUs required to deliver the plan can also be reduced by as much as 85% of the original plan’s MUs. Conclusion Regions of high dose are removed. Dampening overlapping radiation fluence can produce the new beam profiles that have more uniform dose distributions using less MUs. This results in a treatment that requires significantly fewer intensity values than traditional IMRT or VAMT planning.« less
Dosimetric assessment from 212Pb inhalation at a thorium purification plant.
Campos, M P; Pecequilo, B R S
2004-01-01
At the Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, Brazil, there is a facility (thorium purification plant) where materials with high thorium concentrations are manipulated. In order to estimate afterwards the lung cancer risk for the workers, the thoron daughter (212Pb) levels were assessed and the committed effective and lung committed equivalent doses for workers in place. A total of 28 air filter samples were measured by total alpha counting through the modified Kusnetz method, to determine the 212Pb concentraion. The committed effective dose and lung committed equivalent dose due to 212Pb inhalation were derived from compartmental analysis following the ICRP 66 lung compartmental model, and ICRP 67 lead metabolic model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apicello, L; Riegel, A; Jamshidi, A
2015-06-15
Purpose: A sufficient amount of ionizing radiation can cause failure to components of pacemakers. Studies have shown that permanent damage can occur after a dose of 10 Gy and minor damage to functionality occurs at doses as low as 2 Gy. Optically stimulated thermoluminescent dosimeters (OSLDs) can be used as in vivo dosimeters to predict dose to be deposited throughout the treatment. The purpose of this work is to determine the effectiveness of using OSLDs for in vivo dosimetry of pacemaker dose. Methods: As part of a clinical in vivo dosimetry experience, OSLDs were placed at the site of themore » pacemaker by the therapist for one fraction of the radiation treatment. OSLD measurements were extrapolated to the total dose to be received by the pacemaker during treatment. A total of 79 measurements were collected from November 2011 to December 2013 on six linacs. Sixty-six (66) patients treated in various anatomical sites had the dose of their pacemakers monitored. Results: Of the 79 measurements recorded, 76 measurements (96 %) were below 2 Gy. The mean and standard deviation were 50.12 ± 76.41 cGy. Of the 3 measurements that exceeded 2 Gy, 2 measurements matched the dose predicted in the treatment plan and 1 was repeated after an unexpectedly high Result. The repeated measurement yielded a total dose less than 2 Gy. Conclusion: This analysis suggests OSLDs may be used for in vivo monitoring of pacemaker dose. Further research should be performed to assess the effect of increased backscatter from the pacemaker device.« less
Furukawa, Takatoshi; Abe, Yasuhiro; Ito, Tsukasa; Kubota, Toshinori; Kakehata, Seiji
2017-02-01
Large-scale investigations have not been recently conducted on the efficacy of high-dose steroid administration of prednisolone (PSL) for Bell's palsy. We compared treatment results between normal-dose steroid (PSL 60 mg/d) and high-dose steroid (PSL 200 mg/d) + Hespander + Mannitol administration. We also investigated the recovery rate for antiviral agents. Retrospective case review. Tertiary referral center. A total of 675 patients with Bell's palsy who had grade V and grade VI on the House-Brackmann (HB) scale were treated in our department between 1995 and 2014. These patients could be divided into a normal-dose group and high-dose group. We separately assessed treatment outcomes for HB grade V patients and HB grade VI patients. Logistic regression analysis was also performed to investigate factors that can impact treatment outcomes, i.e., sex, age, days to start of treatment, PSL dosage, and antiviral drug administration. Recovery rates were significantly better in the high-dose steroid + Hespander + Mannitol group in comparison with the normal-dose steroid group for HB grade V (100% versus 77.7%) and HB grade VI (92.5% versus 68.2%). Additional effects of antiviral agents were only shown in the normal-dose group. Significant factors for treatment outcomes were PSL 200 mg/d administration and early initiation of treatment. Insignificant factors were sex, age, and the antiviral agent. We showed the high-dose steroid + Hespander + Mannitol administration produced significantly better outcomes than normal-dose steroid administration in the treatment of patients with Bell's palsy.
A simpler method for total scalp irradiation: the multijaw-size concave arc technique.
Inoue, Minoru; Konno, Masahiro; Ogawa, Hirofumi; Harada, Hideyuki; Asakura, Hirofumi; Fuji, Hiroshi; Murayama, Shigeyuki; Nishimura, Tetsuo
2014-07-08
The lateral electron-photon technique (LEPT) and intensity-modulated radiation therapy (IMRT) are commonly used for total scalp irradiation. However, the treatment planning and irradiation are laborious and time-consuming. We herein present the multijaw-size concave arc technique (MCAT) as a total scalp irradiation method that overcomes these problems. CT datasets for eight patients previously treated for angiosarcoma of the scalp were replanned using MCAT, LEPT, and IMRT. The MCAT was designed with a dynamic conformal arc for the total scalp, with a multileaf collimator to shield the brain. Two additional conformal arcs with a decreased upper-jaw position of the first dynamic conformal arc were used to reduce the cranial hotspots. The prescribed dose was 40 Gy (2 Gy/fraction) to 95% of the planning target volume (PTV, defined as the total scalp plus a 4 mm margin). MCAT was compared with LEPT and IMRT with respect to the PTV dose homogeneity (D5%-95%), underdosage (V < 90%), overdosage (V > 110%), doses to the brain, and the delivery time and monitor units (MUs) for single irradiation. We were able to formulate treatment plans for all three techniques that could deliver the prescription dose in all patients. MCAT was significantly superior to LEPT with respect to PTV dose homogeneity, overdosage, and underdosage, although MCAT was inferior to IMRT with respect to dose homogeneity and overdosage. The mean brain dose and high-dosage volume of all three techniques were low, but IMRT provided larger volume to the brain than did the other two techniques in the low dosage region. In MCAT, the mean delivery time could be reduced by approximately half or more, and the mean MUs could be reduced by at least 100 compared to the other two techniques. MCAT can achieve total scalp irradiation with substantially fewer MUs and a shorter delivery time than LEPT and IMRT.
Oral ifosfamide-mesna: a clinical investigation in advanced non-small-cell lung cancer.
Manegold, C; Bischoff, H; Fischer, J R; Löchner, S; Peukert, M; Schmähl, A; Drings, P
1992-11-01
The purpose of this study was to evaluate the toxicity and response efficacy of fixed-dose oral ifosfamide (OI)-mesna (M) in advanced, non-small-cell lung cancer (NSCLC). OI was given in four different fractionated-dose treatment schedules with a total dose per cycle of either 3.0 g/m2, 6.0 g/m2, 7.5 g/m2 or 10 g/m2 (equivalent to a daily dose of either 750 mg, 1000 mg or 1250 mg.) M was given p.o. by drinking ampules. In the 64 patients (pts) included, a total of 305 treatment cycles were administered with no evidence of severe neurotoxicity. Twenty-two pts (37%) developed mild to moderate CNS toxicity. Neither myelosuppression, alopecia, gastrointestinal toxicity nor urotoxicity were clinical problems. On schedule 2 (6 g/m2), 3 of 14 evaluable pts (21%) had partial remissions (PR), and on schedule 3 (7.5 g/m2) 4 pts (25%) showed PRs. The median duration of response was 9 months (mts) for pts on schedule 2, and 8 mts for pts on schedule 3. We conclude that OIM can easily be tolerated in the same dose usually given intravenously (7.5 g/m2/mts), when patients at high risk for developing CNS toxicity have been previously excluded from therapy. In order to reduce CNS toxicity, it is suggested that the total dose per cycle should not exceed 7.5 g/m2 (1000 mg daily) within a fractionated-dose, 14-day treatment schedule. We further conclude that the tumor response efficacy of OIM in NSCLC is comparable to the one achieved by intravenously-administered IM, whereby the total monthly OI dose should not be less than 6.0 g/m2 (750 mg daily).
Effects of food on the pharmacokinetics of ponatinib in healthy subjects.
Narasimhan, N I; Dorer, D J; Niland, K; Haluska, F; Sonnichsen, Daryl
2013-12-01
Ponatinib is a potent oral tyrosine kinase inhibitor with activity against BCR-ABL, the primary driver of chronic myeloid leukaemia and Philadelphia chromosome-positive acute lymphoblastic leukaemia. This single-centre, single-dose, randomized, open-label, three-period crossover study evaluated the pharmacokinetics and bioavailability of a single oral dose of ponatinib (45-mg tablet) under fasting conditions and following consumption of high- and low-fat meals by healthy subjects. Subjects were randomly assigned to one of the six possible treatment sequences, each evaluating three ponatinib 45-mg treatments: administered under fasting conditions; administered after a high-fat meal; or administered after a standardized low-fat meal. The high-fat meal derived approximately 50% of its total caloric content from fat, with approximately 150, 250 and 500-600 calories derived from protein, carbohydrates and fat, respectively (total of approximately 900-1000 calories). The standardized low-fat meal derived no more than 20% of total caloric content from fat, with approximately 56, 428 and 63 calories derived from protein, carbohydrates and fat, respectively (total of approximately 547 calories). During each of the three treatment periods, blood samples were collected predose and at 13 time points over the 96-h post-dose interval. Plasma concentrations of ponatinib were measured by liquid chromatography/tandem mass spectrometry. Mixed-model analyses of variance (anova) were performed on natural log-transformed PK parameters Cmax and AUC0-∞. Geometric mean maximum plasma concentration (Cmax) values for the fasted, low-fat and high-fat regimens were 54·7, 51·6 and 51·5 ng/mL, respectively. Geometric mean area under the concentration-time curve from time zero to infinity (AUC0-∞) values for the fasted, low-fat and high-fat regimens were 1273, 1244 and 1392 h × ng/mL, respectively. All limits of the 90% CIs of the estimated geometric mean ratios for Cmax and all AUC comparisons fell within the 80%-125% margins. These results indicate that consumption of a high- or low-fat meal within 30 min prior to administration of ponatinib had no effect on the single-dose pharmacokinetics of ponatinib. Food does not affect the single-dose pharmacokinetics of ponatinib. These data demonstrate that ponatinib may be administered with or without food. © 2013 The Authors. Journal of Clinical Pharmacy and Therapeutics published by John Wiley & Sons Ltd.
Bostom, Andrew G.; Carpenter, Myra A.; Kusek, John W.; Levey, Andrew S.; Hunsicker, Lawrence; Pfeffer, Marc A.; Selhub, Jacob; Jacques, Paul F.; Cole, Edward; Gravens-Mueller, Lisa; House, Andrew A.; Kew, Clifton; McKenney, Joyce L.; Pacheco-Silva, Alvaro; Pesavento, Todd; Pirsch, John; Smith, Stephen; Solomon, Scott; Weir, Matthew
2015-01-01
Background Kidney transplant recipients, like other patients with chronic kidney disease (CKD), experience excess risk of cardiovascular disease (CVD) and elevated total homocysteine (tHcy) concentrations. Observational studies of patients with CKD suggest increased homocysteine is a risk factor for CVD. The impact of lowering total homocysteine (tHcy) levels in kidney transplant recipients is unknown. Methods and Results In a double-blind controlled trial, we randomized 4110 stable kidney transplant recipients to a multivitamin that included either a high dose (n=2056) or low dose (n=2054) of folic acid, vitamin B6, and vitamin B12 to determine whether decreasing tHcy concentrations reduced the rate of the primary composite arteriosclerotic CVD outcome (myocardial infarction, stroke, CVD death, resuscitated sudden death, coronary artery or renal artery revascularization, lower extremity arterial disease, carotid endarterectomy or angioplasty, or abdominal aortic aneurysm repair). Mean follow-up was 4.0 years. Treatment with the high dose multivitamin reduced homocysteine but did not reduce the rates of the primary outcome (n= 547 total events; hazards ratio [95% confidence interval] = 0.99 [0.84–1.17]), or secondary outcomes of all-cause mortality (n=431 deaths; 1.04 [0.86–1.26]) or dialysis-dependent kidney failure (n=343 events; 1.15 [0.93–1.43]) compared to the low dose multivitamin. Conclusions Treatment with a high dose folic acid, B6, and B12 multivitamin in kidney transplant recipients did not reduce a composite cardiovascular disease outcome, all-cause mortality, or dialysis-dependent kidney failure despite significant reduction in homocysteine level. PMID:21482964
What is the Ideal Route of Administration of Tranexamic Acid in TKA? A Randomized Controlled Trial.
Lee, Sung Yup; Chong, Suri; Balasubramanian, Dhanasekaraprabu; Na, Young Gon; Kim, Tae Kyun
2017-08-01
TKA commonly involves substantial blood loss and tranexamic acid has been used to reduce blood loss after TKA. Numerous clinical trials have documented the efficacy and safety of intravenous (IV) or intraarticular (IA) use of tranexamic acid. Combined administration of tranexamic acid also has been suggested; however, there is no consensus regarding the ideal route of tranexamic acid administration. (1) To compare the efficacy of tranexamic acid in terms of total blood loss and the allogeneic transfusion rate among three routes of administration: IV alone, IA alone, and combined IV and IA. (2) To compare these regimens in terms of venous thromboembolism (VTE) and the frequency of wound complications. In total, 376 patients undergoing TKA between March 2014 and March 2015 were randomized to four groups by the route of tranexamic acid administration: IV only, IA only, low-dose combined (IV + IA injection of 1 g), and high-dose combined (IV + IA injection of 2 g). The calculated total blood loss, allogeneic transfusion rate, decrease in hemoglobin, the frequency of symptomatic deep vein thrombosis and pulmonary embolism, wound complications, and periprosthetic joint infection were compared among the groups. Total blood loss was calculated using estimated total body blood volume and hemoglobin loss. The decision regarding when to transfuse was determined based on preset criteria. The high- and low-dose combined groups and the IA-only group had lower total blood loss (564 ± 242 mL, 642 ± 242 mL, and 633 ± 205 mL, respectively) than the IV-only group (764 ± 217 mL; mean differences = 199 mL [95% CI, 116-283 mL], p < 0.001; 121 mL [95% CI, 38-205 mL], p = 0.001; 131 mL [95% CI, 47-214 mL], p < 0.001); no differences were found among the other three groups. No patients in any study group received an allogeneic transfusion. One patient in the IV-only group had a symptomatic pulmonary embolism develop, but no other symptomatic VTE events occurred in any group. In addition, no differences were observed in wound complications, such as superficial wound necrosis (one patient in the IV-only and the high-dose combined group, respectively) and oozing (IV-only, IA-only, low-dose combined, high-dose combined = 3%, 4%, 4%, and 7%; p = 0.572) between the groups. No patients had a periprosthetic joint infection. IA tranexamic acid administration further reduces blood loss after TKA in comparison to IV use alone; no additional effect in further reducing blood loss was found in combination with IV tranexamic acid. Appropriately powered studies are needed to confirm the safety of this route of administration as the preferred route of administration in TKA. Level I, therapeutic study.
Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim
2016-09-25
Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.
High-dose anti-histamine use and risk factors in children with urticaria
Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu
2016-01-01
Aim The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. Material and Methods The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. Results The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p<0.0001). There was no difference between the two groups in terms of blood eosinophil and basophil counts, and serum total IgE levels (p>0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=−0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03–1.15]) and basopenia (OR: 6.77; CI 95%: [2.01–22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. Conclusion The requirement of high-dose H1-antihistamines was higher with children’s increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines. PMID:28123332
El-Qutob, David; Moreno, Francisco; Subtil-Rodríguez, Alicia
2016-07-01
Effectiveness of a 9-month specific immunotherapy with a subcutaneous hypoallergenic high-dose house dust mite extract to reduce allergic symptoms as perceived by patients and physicians was assessed. An observational, retrospective, multicenter study was carried out in patients diagnosed with asthma and/or rhinitis caused by house dust mites having started specific immunotherapy with Acaroid(®). Primary end point was perceived effectiveness. A total of 409 patients were included. According to physician-completed visual analogue scale, a 58.1% clinical improvement was observed. Patient-completed visual analogue scale showed a 69.8% clinical improvement. The need for unscheduled/emergency healthcare, as an indication of poor quality of life, showed a significant reduction. Our results confirm in a real-world setting the findings from randomized clinical trials of high-dose house dust mites allergoid immunotherapy with a subcutaneous hypoallergenic high-dose house dust mite extract.
Clarke, Zoe L; Moat, Stuart J; Miller, Alastair L; Randall, Michael D; Lewis, Malcolm J; Lang, Derek
2006-12-03
The exact mechanism(s) by which hyperhomocysteinaemia promotes vascular disease remains unclear. Moreover, recent evidence suggests that the beneficial effect of folic acid on endothelial function is independent of homocysteine-lowering. In the present study the effect of a low (400 microg/70 kg/day) and high (5 mg/70 kg/day) dose folic acid supplement on endothelium-dependent relaxation in the isolated perfused mesenteric bed of heterozygous cystathionine beta-synthase deficient mice was investigated. Elevated total plasma homocysteine and impaired relaxation responses to methacholine were observed in heterozygous mice. In the presence of N(G)-nitro-L-arginine methyl ester relaxation responses in wild-type tissues were reduced, but in heterozygous tissues were abolished. Clotrimazole and 18alpha-glycyrrhetinic acid, both inhibitors of non-nitric oxide/non-prostanoid-induced endothelium-dependent relaxation, reduced responses to methacholine in wild-type but not heterozygous tissues. The combination of N(G)-nitro-L-arginine methyl ester and either clotrimazole or 18alpha-glycyrrhetinic acid completely inhibited relaxation responses in wild-type tissues. Both low and high dose folic acid increased plasma folate, reduced total plasma homocysteine and reversed endothelial dysfunction in heterozygous mice. A greater increase in plasma folate in the high dose group was accompanied by a more significant effect on endothelial function. In the presence of N(G)-nitro-L-arginine methyl ester, a significant residual relaxation response was evident in tissues from low and high dose folic acid treated heterozygous mice. These data suggest that the impaired mesenteric relaxation in heterozygous mice is largely due to loss of the non-nitric oxide/non-prostanoid component. While low dose folic acid may restore this response in a homocysteine-dependent manner, the higher dose has an additional effect on nitric oxide-mediated relaxation that would appear to be independent of homocysteine lowering.
Tada, Yukie; Yano, Norio; Takahashi, Hiroshi; Yuzawa, Katsuhiro; Ando, Hiroshi; Kubo, Yoshikazu; Nagasawa, Akemichi; Inomata, Akiko; Ogata, Akio; Nakae, Dai
2013-12-01
Information about potential risks of iron nanomaterials is still limited, while a wide variety of applications are expected. We recently reported acute phase responses of male and female Fischer 344 rats after a single intratracheal spray instillation of Fe3O4 nanoparticles (magnetite), clearly showing dose-dependent pulmonary inflammatory changes (Tada et al., J Toxicol Pathol 25, 233-239, 2012). The present study assessed long-term responses of male and female Fischer 344 rats to multiple administrations of magnetite. Ten-week-old male and female Fischer 344 rats (n=20/group) were exposed to a total of 13 quadweekly intermittent intratracheal spray instillations of magnetite during the experimental period of 52 weeks, at doses of 0, 0.2 (low), 1.0 (medium) and 5.0 (high-dose) mg/kg body weight per administration. Absolute and relative lung weights of the high-dose group were significantly higher than those of the control group. Macroscopically, slight enlargement and scattered black patches were recognized in the lungs and the lung-associated lymph nodes of the high-dose group. Histopathologically, infiltration of macrophages phagocytosing magnetite (all dose groups) and of chronic inflammatory cells (medium- and high-dose males and high-dose females), alveolar bronchiolization and granuloma (high-dose group) were observed. In addition, alveolar hyperplasias were observed in some rats of the high-dose group, and cytoplasmic overexpression of β-catenin protein was immunohistochemically found in such lesions. The present results clearly show that instilled magnetite causes chronic inflammatory responses in the lung. These responses occur in a dose-dependent manner without apparent differences among sexes.
Acceleration of atherogenesis in ApoE-/- mice exposed to acute or low-dose-rate ionizing radiation.
Mancuso, Mariateresa; Pasquali, Emanuela; Braga-Tanaka, Ignacia; Tanaka, Satoshi; Pannicelli, Alessandro; Giardullo, Paola; Pazzaglia, Simonetta; Tapio, Soile; Atkinson, Michael J; Saran, Anna
2015-10-13
There is epidemiological evidence for increased non-cancer mortality, primarily due to circulatory diseases after radiation exposure above 0.5 Sv. We evaluated the effects of chronic low-dose rate versus acute exposures in a murine model of spontaneous atherogenesis. Female ApoE-/- mice (60 days) were chronically irradiated for 300 days with gamma rays at two different dose rates (1 mGy/day; 20 mGy/day), with total accumulated doses of 0.3 or 6 Gy. For comparison, age-matched ApoE-/- females were acutely exposed to the same doses and sacrificed 300 days post-irradiation. Mice acutely exposed to 0.3 or 6 Gy showed increased atherogenesis compared to age-matched controls, and this effect was persistent. When the same doses were delivered at low dose rate over 300 days, we again observed a significant impact on global development of atherosclerosis, although at 0.3 Gy effects were limited to the descending thoracic aorta. Our data suggest that a moderate dose of 0.3 Gy can have persistent detrimental effects on the cardiovascular system, and that a high dose of 6 Gy poses high risks at both high and low dose rates. Our results were clearly nonlinear with dose, suggesting that lower doses may be more damaging than predicted by a linear dose response.
Dose commitments due to radioactive releases from nuclear power plant sites in 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less
Dose commitments due to radioactive releases from nuclear power plant sites in 1989. Volume 11
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, D.A.
Population and individual radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1989. Fifty-year dose commitments for a one-year exposure from both liquid and atmospheric releases were calculated for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 72 reactor sites. This report tabulates the results of these calculations, showing the dose commitments for both water and airborne pathways for each age group and organ. Also included for each of the sites is an estimate of individual doses which are compared with 10 CFR Partmore » 50, Appendix I design objectives. The total collective dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 14 person-rem to a low of 0.005 person-rem for the sites with plants in operation and producing power during the year. The arithmetic mean was 1.2 person-rem. The total population dose for all sites was estimated at 84 person-rem for the 140 million people considered at risk. The individual dose commitments estimated for all sites were below the Appendix I design objectives.« less
Implementation and application of an interactive user-friendly validation software for RADIANCE
NASA Astrophysics Data System (ADS)
Sundaram, Anand; Boonn, William W.; Kim, Woojin; Cook, Tessa S.
2012-02-01
RADIANCE extracts CT dose parameters from dose sheets using optical character recognition and stores the data in a relational database. To facilitate validation of RADIANCE's performance, a simple user interface was initially implemented and about 300 records were evaluated. Here, we extend this interface to achieve a wider variety of functions and perform a larger-scale validation. The validator uses some data from the RADIANCE database to prepopulate quality-testing fields, such as correspondence between calculated and reported total dose-length product. The interface also displays relevant parameters from the DICOM headers. A total of 5,098 dose sheets were used to test the performance accuracy of RADIANCE in dose data extraction. Several search criteria were implemented. All records were searchable by accession number, study date, or dose parameters beyond chosen thresholds. Validated records were searchable according to additional criteria from validation inputs. An error rate of 0.303% was demonstrated in the validation. Dose monitoring is increasingly important and RADIANCE provides an open-source solution with a high level of accuracy. The RADIANCE validator has been updated to enable users to test the integrity of their installation and verify that their dose monitoring is accurate and effective.
Older adults and high-risk medication administration in the emergency department
Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J
2017-01-01
Background Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). Patients and methods ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated (“High doses” were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; “very high doses” were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65–69, 70–74, 75–79, 80–84, and ≥85 years), gender, and hospital. Results There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65–69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56–11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69–18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26–1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07–2.16). Conclusion Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65–69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted. PMID:29184448
Wilson, Jolaine M.; Sanzari, Jenine K.; Diffenderfer, Eric S.; Yee, Stephanie S.; Seykora, John T.; Maks, Casey; Ware, Jeffrey H.; Litt, Harold I.; Reetz, Jennifer A.; McDonough, James; Weissman, Drew; Kennedy, Ann R.; Cengel, Keith A.
2011-01-01
In a solar particle event (SPE), an unshielded astronaut would receive proton radiation with an energy profile that produces a highly inhomogeneous dose distribution (skin receiving a greater dose than internal organs). The novel concept of using megavoltage electron-beam radiation to more accurately reproduce both the total dose and the dose distribution of SPE protons and make meaningful RBE comparisons between protons and conventional radiation has been described previously. Here, Yucatan minipigs were used to determine the effects of a superficial, SPE-like proton dose distribution using megavoltage electrons. In these experiments, dose-dependent increases in skin pigmentation, ulceration, keratinocyte necrosis and pigment incontinence were observed. Five of 18 animals (one each exposed to 7.5 Gy and 12.5 Gy radiation and three exposed to 25 Gy radiation) developed symptomatic, radiation-associated pneumonopathy approximately 90 days postirradiation. The three animals from the highest dose group showed evidence of mycoplasmal pneumonia along with radiation pneumonitis. Moreover, delayed-type hypersensitivity was found to be altered, suggesting that superficial irradiation of the skin with ionizing radiation might cause immune dysfunction or dysregulation. In conclusion, using total doses, patterns of dose distribution, and dose rates that are compatible with potential astronaut exposure to SPE radiation, animals experienced significant toxicities that were qualitatively different from toxicities previously reported in pigs for homogeneously delivered radiation at similar doses. PMID:21859326
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, S; Department of Biomedical Engineering, University of North Carolina- Chapel Hill/ North Carolina State University, Chapel Hill, North Carolina; Lineberger Clinical Cancer Center, University of North Carolina, Chapel Hill, NC
Purpose: Ultrahigh dose-rate radiation at >40Gy/s has demonstrated astonishing normal-tissue sparing and tumor control in recent preclinical naive and tumor-bearing rodent studies when compared to the same radiation dose at a conventional dose-rate. The working mechanism of this fascinating dose-rate effect is currently under investigation. The aims of this work include investigating 1) whether LINAC FFF mode radiation at approximately 1Gy/s also has an improved therapeutic ratio compared to the same radiation dose at the conventional dose-rate of 0.05Gy/s, and 2) the dose-rate effect’s potential working mechanism by studying the expression of the P53 gene, linked to tumor suppression andmore » cell regulation after radiation damage. Methods: We used mouse model C57BL/6J, the same as that used in the ultrahigh dose-rate studies, and exposed them to total body irradiation (TBI) using the Elekta Versa accelerator 10MV photons. Mice (N=20) were given a total dose of 12Gy in both the high dose-rate group (n=10) using the FFF-mode and the conventional dose-rate group (n=10) using the conventional does rate mode. The FFF-mode treatment setup consisted of a 15cm×15cm field size setting at 53.2cm SSD while the conventional-mode set-up consisted of a 10cm×10cm field size at 100SSD. Post-radiation, animals were monitored daily for survival analysis and signs of moribundity requiring euthanasia. In addition, mouse spleens were harvested for P53 analysis at different time points. Results: For 12Gy TBI, the 1.3Gy/s FFF-mode high dose-rate produced a statistically significant (p=0.02) improvement in mouse survival compared to the 0.05Gy/s conventional dose-rate. An initial P53 study at the time of death time-point indicates that high dose-rate radiation induced a stronger expression of P53 than conventional dose-rate radiation. Conclusion: Our pilot study indicates that the FFF-mode high dose-rate radiation, which has been used largely to improve clinical throughput, may provide the added clinical benefit of improving treatment therapeutic ratio. Animal Studies were performed within the LCCC Animal Studies Core Facility at the University of North Carolina at Chapel Hill. The LCCC Animal Studies Core is supported in part by an NCI Center Core Support Grant (CA16086) to the UNC Lineberger Comprehensive Cancer Center.« less
Koplay, Mustafa; Celik, Mahmut; Avcı, Ahmet; Erdogan, Hasan; Demir, Kenan; Sivri, Mesut; Nayman, Alaaddin
2015-01-01
We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated "Flash Spiral" technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47-2.01 mSv) for method A and 8.22 mSv (2.19-12.88 mSv) for method B. Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Storb, R.; Raff, R.F.; Graham, T.
1993-03-20
The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing [sup 60]Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionatedmore » total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs.« less
Anti-Proliferative Properties of Cornus mass Fruit in Different Human Cancer Cells.
Yousefi, Bahman; Abasi, Mozhgan; Abbasi, Mehran Mesgari; Jahanban-Esfahlan, Rana
2015-01-01
There is a long standing interest in natural compounds especially those with a high polyphenolic content and high scavenging activity for hazardous free radicals. Cornus mas (CM) fruit is well known for its antioxidant activities; however, its toxicity against human cancers needs to be addressed. Here, we investigated selective anticancer effects of CM on different human cancer cells. A hydro-alcoholic extract of CM (HECM) was prepared and total phenolic content (TPC) and total flavonoid content (TFC) were determined by colorimetric assays. Antioxidant activity was assessed with respectto DPPH radical scavenging. MTT assays were used to evaluate the cytotoxicity of different doses of CM (0, 5, 20, 100, 250, 500, 1000 μg/ ml) towards A549 (lung non small cell cancer), MCF-7 (breast adenocarcinoma), SKOV3 (ovarian cancer) and PC-3 (prostate adenocarcinoma) cells. Significant (P<0.05) or very significant (P<0.001) differences were observed in comparison to negative controls at all tested doses (5-1000 μg/ml). In all cancer cells, HECM reduced the cell viability to values below 26%, even at the lowest doses. In all cases, IC50 was obtained at doses below 5μg/ml. The mean growth inhibition was 81.8%, 81.9%, 81.6% and 79.3% in SKOV3, MCF-7, PC-3 and A549 cells, respectively. Altogether, to our best knowledge, this is a first study that evaluated toxicity of a HECM with high antioxidant activity in different human cancer cells in vitro. Our results indicated that a hydro-alcoholic extract of CM possesses high potency to inhibit proliferation of different tumor cells in a dose independent manner, suggesting that an optimal biological dose is more important and relevant than a maximally tolerated one.
Horikawa, Reiko; Tanaka, Toshiaki; Nishinaga, Hiromi; Ogawa, Yoshihisa; Yokoya, Susumu
2017-01-01
Abstract. Some children born small for gestational age (SGA) have short stature and are at an increased risk of developing psychosocial or behavioral problems. Here we evaluated the efficacy of GH and its effects on the timing of pubertal onset in a 3-yr extension of our previous 2-yr (total 5 yr) multicenter, randomized, double-blind, parallel-group clinical trial of 65 short Japanese children born SGA. Patients received low or high doses of GH (0.033 or 0.067 mg/kg/day, respectively). Age at onset of puberty was not statistically different for male and female patients receiving high- or low-dose GH. After the onset of puberty, no difference in height gain was observed between the two GH dose groups. At the onset of puberty, height standard deviation scores for chronological age of boys and girls improved significantly in both dose groups with evidence of a dose-response effect. Mean bone age/chronological age ratios in the low- and high-dose groups were significantly increased compared with baseline, being significantly greater in the high-dose group at 5 yr after treatment initiation. Delayed bone age at baseline was close to chronological age following GH treatment. GH treatment, especially high-dose GH, induced advanced bone age in short children born SGA. PMID:28458458
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takam, Rungdham; Bezak, Eva; Yeoh, Eric E.
2010-09-15
Purpose: Normal tissue complication probability (NTCP) of the rectum, bladder, urethra, and femoral heads following several techniques for radiation treatment of prostate cancer were evaluated applying the relative seriality and Lyman models. Methods: Model parameters from literature were used in this evaluation. The treatment techniques included external (standard fractionated, hypofractionated, and dose-escalated) three-dimensional conformal radiotherapy (3D-CRT), low-dose-rate (LDR) brachytherapy (I-125 seeds), and high-dose-rate (HDR) brachytherapy (Ir-192 source). Dose-volume histograms (DVHs) of the rectum, bladder, and urethra retrieved from corresponding treatment planning systems were converted to biological effective dose-based and equivalent dose-based DVHs, respectively, in order to account for differences inmore » radiation treatment modality and fractionation schedule. Results: Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75 Gy/fraction delivered five times/week to total dose of 55 Gy), NTCP of the rectum, bladder, and urethra were less than those for standard fractionated 3D-CRT using a four-field technique (32 fractions of 2 Gy/fraction delivered five times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6%, respectively) following the dose-escalated four-field 3D-CRT (2 Gy/fraction to total dose of 74 Gy) were the highest among analyzed treatment techniques. The average NTCP for the rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT. Conclusions: Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques other than the urethra because of much smaller volumes irradiated to higher doses. Among analyzed normal tissues, the femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues.« less
Davis, Gary L; Nelson, David R; Terrault, Norah; Pruett, Timothy L; Schiano, Thomas D; Fletcher, Courtney V; Sapan, Christine V; Riser, Laura N; Li, Yufeng; Whitley, Richard J; Gnann, John W
2005-08-01
Chronic hepatitis C is the most common indication for liver transplantation, but viral recurrence is universal and progressive graft injury occurs in most recipients. Our aim was to assess the safety, pharmacokinetics (PK), and antiviral effects of high doses of a human hepatitis C antibody enriched immune globulin product (HCIG) in patients undergoing liver transplantation for chronic hepatitis C. This was a multicenter, randomized, open-label, controlled trial conducted at 4 transplant centers in the United States. A total of 18 patients with chronic hepatitis C, who underwent liver transplantation, were randomized to receive low-dose HCIG (75 mg/kg) or high-dose HCIG (200 mg/kg), or no treatment. A total of 17 infusions of HCIG were administered in each treated patient over 14 weeks using a time-dependent dosing strategy based on the PK of anti-hepatitis B immune globulin in liver transplant recipients. Hepatitis C virus levels, liver enzymes, and liver biopsies were obtained serially throughout the study period. PK profiles of HCV antibodies were determined on days 4, 10, and 98. HCIG infusions were safe and tolerated. The infusion rate could not be maximized because of symptoms for 18% to 30% of the doses. The half-life of HCIG was extremely short immediately after transplantation but was gradually prolonged. In the high-dose group, serum alanine aminotransferase (ALT) levels normalized in most subjects and no patient developed hepatic fibrosis. However, serum HCV RNA levels were not suppressed at either dose. In conclusion, HCIG, an anti-HCV enriched immune globulin product, appears to be safe in patients with chronic hepatitis C undergoing liver transplantation. Further studies are required to determine whether the drug has beneficial effects in this group of patients.
210Po in the diet at Seville (Spain) and its contribution to the dose by ingestion
Díaz-Francés, I.; Mantero, J.; Díaz-Ruiz, J.; Manjón, G.; García-Tenorio, R.
2016-01-01
The activity concentrations of 210Po have been determined in a total of 24 representative diet samples from Seville (south of Spain), inferring from the obtained values the annual intakes of 210Po by ingestion of the affected population and the corresponding committed effective doses. The annual intakes of 210Po and, consequently, the corresponding doses of this radionuclide show a high variability in correspondence with the variability in the composition of the analysed samples over time, and their magnitude is comparable with the estimated ones in other regions/countries of the world with similar diet habits (countries where the marine products have a considerable weight in the diets). Committed effective doses by ingestion higher than 0.1 mSv y−1 have been estimated exclusively for 210Po, reflecting the importance of this radionuclide and this route of incorporation in the magnitude of the total doses received by the affected population from natural sources. PMID:25802464
Cost Evaluation of a Government-Conducted Oral Cholera Vaccination Campaign-Haiti, 2013.
Routh, Janell A; Sreenivasan, Nandini; Adhikari, Bishwa B; Andrecy, Lesly L; Bernateau, Margarette; Abimbola, Taiwo; Njau, Joseph; Jackson, Ernsley; Juin, Stanley; Francois, Jeannot; Tohme, Rania A; Meltzer, Martin I; Katz, Mark A; Mintz, Eric D
2017-10-01
The devastating 2010 cholera epidemic in Haiti prompted the government to introduce oral cholera vaccine (OCV) in two high-risk areas of Haiti. We evaluated the direct costs associated with the government's first vaccine campaign implemented in August-September 2013. We analyzed data for major cost categories and assessed the efficiency of available campaign resources to vaccinate the target population. For a target population of 107,906 persons, campaign costs totaled $624,000 and 215,295 OCV doses were dispensed. The total vaccine and operational cost was $2.90 per dose; vaccine alone cost $1.85 per dose, vaccine delivery and administration $0.70 per dose, and vaccine storage and transport $0.35 per dose. Resources were greater than needed-our analyses suggested that approximately 2.5-6 times as many persons could have been vaccinated during this campaign without increasing the resources allocated for vaccine delivery and administration. These results can inform future OCV campaigns in Haiti.
Disposition and pharmacokinetics in rats of McN-5707, a potential antidepressant drug
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, K.T.; Holland, M.L.; Hills, J.F.
1986-03-01
A single 80 mg/kg oral solution dose of McN-5707-/sup 14/C x HBr (trans-6-(2-chlorophenyl)-1,2,3,5,6,10b-hexahydropyrrolo(2,1-a)isoquinoline hydrobromide (1:1)) was administered orally to 40 Wistar rats. Total /sup 14/C concentrations in plasma were high (> 4.5 ..mu..g x equiv/mL) for at least 24 hours after dosing. Unchanged McN-5707 represented < 10% of the total /sup 14/C concs in plasma at 45 min and < 1% at 24 hours after dosing. In the 8 days following dose administration, 23% of the dose was excreted in urine and 70% of the dose was excreted in feces. Analysis (HPLC and TLC) of glusulase treated urine, plasma andmore » fecal samples revealed the presence of multiple metabolites of McN-5707. Unchanged McN-5707 was found only in fecal extracts (2-7% of dose). Single solution doses of McN-5707 x HBr were administered p.o. (20 mg/kg) and i.v. (4 mg/kg) to 39 Wistar rats. Plasma samples were analyzed for McN-5707 using a capillary GC assay. These studies indicated that McN-5707 was well absorbed and extensively metabolized in rats following oral doses.« less
Long, D R; Lihn, A L; Friedrich, S; Scheffenbichler, F T; Safavi, K C; Burns, S M; Schneider, J C; Grabitz, S D; Houle, T T; Eikermann, M
2018-05-01
The use of intraoperative opioids may influence the rate of postoperative complications. This study evaluated the association between intraoperative opioid dose and the risk of 30-day hospital readmission. We conducted a pre-specified analysis of existing registry data for 153 902 surgical cases performed under general anaesthesia at Massachusetts General Hospital and two affiliated medical centres. We examined the association between total intraoperative opioid dose (categorised in quintiles) and 30-day hospital readmission, controlling for several patient-, anaesthetist-, and case-specific factors. Compared with low intraoperative opioid dosing [quintile 1, median (inter-quartile range): 8 (4-9) mg morphine equivalents], exposure to high-dose opioids during surgery [quintile 5: 32 (27-41) equivalents] is an independent predictor of 30-day readmission [odds ratio (OR) 1.15 (95% confidence interval 1.07-1.24); P<0.001]. Ambulatory surgery patients receiving high opioid doses were found to have the greatest adjusted risk of readmission (OR 1.75; P<0.001) with a clear dose-response effect across quintiles (P for trend <0.05), and were more likely to be readmitted early (postoperative days 0-2 vs 3-30; P<0.001). Opioid class modified the association between total opioid dose and readmission, with longer-acting opioids demonstrating a stronger influence (P<0.001). We observed significant practice variability across individual anaesthetists in the utilisation of opioids that could not be explained by patient- and case-specific factors. High intraoperative opioid dose is a modifiable anaesthetic factor that varies in the practice of individual anaesthetists and affects postoperative outcomes. Conservative standards for intraoperative opioid dosing may reduce the risk of postoperative readmission, particularly in ambulatory surgery. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Study of the dose rate effect of 180 nm nMOSFETs
NASA Astrophysics Data System (ADS)
He, Bao-Ping; Yao, Zhi-Bin; Sheng, Jiang-Kun; Wang, Zu-Jun; Huang, Shao-Yan; Liu, Min-Bo; Xiao, Zhi-Gang
2015-01-01
Radiation induced offstate leakage in the shallow trench isolation regions of SIMC 0.18 μm nMOSFETs is studied as a function of dose rate. A “true” dose rate effect (TDRE) is observed. Increased damage is observed at low dose rate (LDR) than at high dose rate (HDR) when annealing is taken into account. A new method of simulating radiation induced degradation in shallow trench isolation (STI) is presented. A comparison of radiation induced offstate leakage current in test nMOSFETs between total dose irradiation experiments and simulation results exhibits excellent agreement. The investigation results imply that the enhancement of the leakage current may be worse for the dose rate encountered in the environment of space.
Space radiation dose estimates on the surface of Mars
NASA Technical Reports Server (NTRS)
Simonsen, Lisa C.; Nealy, John E.; Townsend, Lawrence W.; Wilson, John W.
1990-01-01
The Langley cosmic ray transport code and the Langley nucleon transport code (BRYNTRN) are used to quantify the transport and attenuation of galactic cosmic rays (GCR) and solar proton flares through the Martian atmosphere. Surface doses are estimated using both a low density and a high density carbon dioxide model of the atmosphere which, in the vertical direction, provides a total of 16 g/sq cm and 22 g/sq cm of protection, respectively. At the Mars surface during the solar minimum cycle, a blood-forming organ (BFO) dose equivalent of 10.5 to 12 rem/yr due to galactic cosmic ray transport and attenuation is calculated. Estimates of the BFO dose equivalents which would have been incurred from the three large solar flare events of August 1972, November 1960, and February 1956 are also calculated at the surface. Results indicate surface BFO dose equivalents of approximately 2 to 5, 5 to 7, and 8 to 10 rem per event, respectively. Doses are also estimated at altitudes up to 12 km above the Martian surface where the atmosphere will provide less total protection.
Blume, K G; Forman, S J
1992-12-01
High-dose etoposide has been added to total body irradiation, cyclophosphamide, carmustine, or busulfan in preparatory regimens for allogeneic or autologous bone marrow transplantation for patients with leukemia, Hodgkin's disease, lymphoma, or multiple myeloma. The treatment results are encouraging, indicating that etoposide may be a valuable addition to the previously established regimens. Etoposide should be incorporated into collaborative, prospective trials to define its ultimate role in bone marrow transplantation.
Antar, A; Otrock, Z K; Kharfan-Dabaja, M A; Ghaddara, H A; Kreidieh, N; Mahfouz, R; Bazarbachi, A
2015-06-01
The optimal stem cell mobilization regimen for patients with multiple myeloma (MM) remains undefined. We retrospectively compared our experience in hematopoietic cell mobilization in 83 MM patients using fractionated high-dose CY and G-CSF with G-CSF plus preemptive plerixafor. All patients in the CY group (n=56) received fractionated high-dose CY (5 g/m(2) divided into five doses of 1 g/m(2) every 3 h) with G-CSF. All patients in the plerixafor group (n=27) received G-CSF and plerixafor preemptively based on an established algorithm. Compared with plerixafor, CY use was associated with higher total CD34+ cell yield (7.5 × 10(6) vs 15.5 × 10(6) cells/kg, P=0.005). All patients in both groups yielded ⩾4 × 10(6) CD34+ cells/kg. Conversely, CY use was associated with high frequency of febrile neutropenia, blood and platelet transfusions need and hospitalizations. The average total cost of mobilization in Lebanon was slightly higher in the plerixafor group ($7886 vs $7536; P=0.16). Our data indicate robust stem cell mobilization in MM patients with either fractionated high-dose CY and G-CSF or G-CSF alone with preemptive plerixafor. The chemo-mobilization approach was associated with twofold stem cell yield, slightly lower cost but significantly increased toxicity.
Effect of Vaginal or Systemic Estrogen on Dynamics of Collagen Assembly in the Rat Vaginal Wall1
Montoya, T. Ignacio; Maldonado, P. Antonio; Acevedo, Jesus F.; Word, R. Ann
2014-01-01
ABSTRACT The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. PMID:25537371
Effect of vaginal or systemic estrogen on dynamics of collagen assembly in the rat vaginal wall.
Montoya, T Ignacio; Maldonado, P Antonio; Acevedo, Jesus F; Word, R Ann
2015-02-01
The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. © 2015 by the Society for the Study of Reproduction, Inc.
Toxicity of dietary Heliotropium circinatum to rats.
Eröksüz, H; Eröksüz, Y; Ozer, H; Ceribasi, A O; Tosun, F; Tamer, U; Kizilay, C Akyüz
2003-08-01
Pyrrolizidine alkaloid intoxication was produced in adult, male rats by feeding different levels (0, 1, 3, 5 or 10%) of Heliotropium circinatum for 20 w. Combined GC-MS revealed 0.15% total alkaloid content in the plant material of which 12% and 88% were basic and N-oxide forms, respectively. The specific alkaloids identified were europine (67.33%), heliotrine (16.34%), lasiocarpine (8.12%), heleurine (4.18%), echinatine (1.56%), 7-angeylheliotrine (1.19%), and an unknown alkaloid (1.28%). Neither mortality nor significant clinical changes occurred in test groups. Mild to moderate, dose-related hepatic megalocytosis was the most prominent histopathological finding. In addition to chronic hepatotoxicity, notable medial thickening occurred in the pulmonary arterioles and arteries of the high-dosed groups. This study indicated that H. circinatum plant has limited toxic potential in rats with mild to moderate histological changes and no mortality at the dosing levels, total doses, or time of exposure employed.
Isanaka, Sheila; Mugusi, Ferdinand; Hawkins, Claudia; Spiegelman, Donna; Okuma, James; Aboud, Said; Guerino, Chalamilla; Fawzi, Wafaie W
2012-10-17
Large randomized trials have previously shown that high-dose micronutrient supplementation can increase CD4 counts and reduce human immunodeficiency virus (HIV) disease progression and mortality among individuals not receiving highly active antiretroviral therapy (HAART); however, the safety and efficacy of such supplementation has not been established in the context of HAART. To test the hypothesis that high-dose multivitamin supplementation vs standard-dose multivitamin supplementation decreases the risk of HIV disease progression or death and improves immunological, virological, and nutritional parameters in patients with HIV initiating HAART. A randomized, double-blind, controlled trial of high-dose vs standard-dose multivitamin supplementation for 24 months in 3418 patients with HIV initiating HAART between November 2006 and November 2008 in 7 clinics in Dar es Salaam, Tanzania. INTERVENTION The provision of daily oral supplements of vitamin B complex, vitamin C, and vitamin E at high levels or standard levels of the recommended dietary allowance. The composite of HIV disease progression or death from any cause. The study was stopped early in March 2009 because of evidence of increased levels of alanine transaminase (ALT) in patients receiving the high-dose multivitamin supplement. At the time of stopping, 3418 patients were enrolled (median follow-up, 15 months), and there were 2374 HIV disease progression events and 453 observed deaths (2460 total combined events). Compared with standard-dose multivitamin supplementation, high-dose supplementation did not reduce the risk of HIV disease progression or death. The absolute risk of HIV progression or death was 72% in the high-dose group vs 72% in the standard-dose group (risk ratio [RR], 1.00; 95% CI, 0.96-1.04). High-dose supplementation had no effect on CD4 count, plasma viral load, body mass index, or hemoglobin level concentration, but increased the risk of ALT elevations (1239 events per 1215 person-years vs 879 events per 1236 person-years; RR, 1.44; 95% CI, 1.11-1.87) vs standard-dose supplementation. CONCLUSION In adults receiving HAART, use of high-dose multivitamin supplements compared with standard-dose multivitamin supplements did not result in a decrease in HIV disease progression or death but may have resulted in an increase in ALT levels. Clinicaltrials.gov Identifier: NCT00383669.
Comparison in vivo Study of Genotoxic Action of High- Versus Very Low Dose-Rate γ-Irradiation
Osipov, A. N.; Klokov, D. Y.; Elakov, A. L.; Rozanova, O. M.; Zaichkina, S. I.; Aptikaeva, G. F.; Akhmadieva, A. Kh.
2004-01-01
The aim of the present study was to compare genotoxicity induced by high- versus very low dose-rate exposure of mice to γ-radiation within a dose range of 5 to 61 cGy using the single-cell gel electrophoresis (comet) assay and the micronucleus test. CBA/lac male mice were irradiated at a dose rate of 28.2 Gy/h (high dose rate) or 0.07 mGy/h (very low dose rate). The comet assay study on spleen lymphocytes showed that very low dose-rate irradiation resulted in a statistically significant increase in nucleoid relaxation (DNA breaks), starting from a dose of 20 cGy. Further prolongation of exposure time and, hence, increase of a total dose did not, however, lead to further increase in the extent of nucleoid relaxation. Doses of 20 and 61 cGy were equal in inducing DNA breaks in mouse spleen lymphocytes as assayed by the comet assay. Of note, the level of DNA damage by 20–61 cGy doses of chronic irradiation (0.07 mGy/h) was similar to that an induced by an acute (28.2 Gy/h) dose of 14 cGy. The bone marrow micronucleus test revealed that an increase in polychromatic erythrocytes with micronuclei over a background level was induced by very low-level γ-irradiation with a dose of 61 cGy only, with the extent of the cytogenetic effect being similar to that of 10 cGy high-dose-rate exposure. In summary, presented results support the hypothesis of the nonlinear threshold nature of mutagenic action of chronic low dose-rate irradiation. PMID:19330145
Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko
2013-03-01
To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.
Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?
Villemain, Olivier; Malekzadeh-Milani, Sophie; Sitefane, Fidelio; Mostefa-Kara, Meriem; Boudjemline, Younes
2018-05-01
The aims of this study were to describe radiation level at our institution during transcatheter patent ductus arteriosus occlusion and to evaluate the components contributing to radiation exposure. Transcatheter occlusion relying on X-ray imaging has become the treatment of choice for patients with patent ductus arteriosus. Interventionists now work hard to minimise radiation exposure in order to reduce risk of induced cancers. We retrospectively reviewed all consecutive children who underwent transcatheter closure of patent ductus arteriosus from January 2012 to January 2016. Clinical data, anatomical characteristics, and catheterisation procedure parameters were reported. Radiation doses were analysed for the following variables: total air kerma, mGy; dose area product, Gy.cm2; dose area product per body weight, Gy.cm2/kg; and total fluoroscopic time. A total of 324 patients were included (median age=1.51 [Q1-Q3: 0.62-4.23] years; weight=10.3 [6.7-17.0] kg). In all, 322/324 (99.4%) procedures were successful. The median radiation doses were as follows: total air kerma: 26 (14.5-49.3) mGy; dose area product: 1.01 (0.56-2.24) Gy.cm2; dose area product/kg: 0.106 (0.061-0.185) Gy.cm2/kg; and fluoroscopic time: 2.8 (2-4) min. In multivariate analysis, a weight >10 kg, a ductus arteriosus width <2 mm, complications during the procedure, and a high frame rate (15 frames/second) were risk factors for an increased exposure. Lower doses of radiation can be achieved with subsequent recommendations: technical improvement, frame rate reduction, avoidance of biplane cineangiograms, use of stored fluoroscopy as much as possible, and limitation of fluoroscopic time. A greater use of echocardiography might even lessen the exposure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hattangadi, Jona A.; Chapman, Paul H.; Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA
2012-06-01
Purpose: To evaluate patients with high-risk cerebral arteriovenous malformations (AVMs), based on eloquent brain location or large size, who underwent planned two-fraction proton stereotactic radiosurgery (PSRS). Methods and Materials: From 1991 to 2009, 59 patients with high-risk cerebral AVMs received two-fraction PSRS. Median nidus volume was 23 cc (range, 1.4-58.1 cc), 70% of cases had nidus volume {>=}14 cc, and 34% were in critical locations (brainstem, basal ganglia). Median AVM score based on age, AVM size, and location was 3.19 (range, 0.9-6.9). Many patients had prior surgery or embolization (40%) or prior PSRS (12%). The most common prescription was 16more » Gy radiobiologic equivalent (RBE) in two fractions, prescribed to the 90% isodose. Results: At a median follow-up of 56.1 months, 9 patients (15%) had total and 20 patients (34%) had partial obliteration. Patients with total obliteration received higher total dose than those with partial or no obliteration (mean dose, 17.6 vs. 15.5 Gy (RBE), p = 0.01). Median time to total obliteration was 62 months (range, 23-109 months), and 5-year actuarial rate of partial or total obliteration was 33%. Five-year actuarial rate of hemorrhage was 22% (95% confidence interval, 12.5%-36.8%) and 14% (n = 8) suffered fatal hemorrhage. Lesions with higher AVM scores were more likely to hemorrhage (p = 0.024) and less responsive to radiation (p = 0.026). The most common complication was Grade 1 headache acutely (14%) and long term (12%). One patient developed a Grade 2 generalized seizure disorder, and two had mild neurologic deficits. Conclusions: High-risk AVMs can be safely treated with two-fraction PSRS, although total obliteration rate is low and patients remain at risk for future hemorrhage. Future studies should include higher doses or a multistaged PSRS approach for lesions more resistant to obliteration with radiation.« less
NASA Technical Reports Server (NTRS)
Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.
2001-01-01
The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.
Pierce, Dwayne A; Russell, Greg; Pirkle, James L
2015-12-01
Hyperkalemia is a potentially life-threatening condition that is common in kidney disease patients. Insulin is used to treat hyperkalemia, but may cause hypoglycemia, especially in kidney disease when insulin may be metabolized more slowly. We compared the rates of hypoglycemia in patients with low estimated glomerular filtration rate (eGFR) using high versus low doses of insulin for hyperkalemia to determine if lower doses of insulin would decrease the incidence of hypoglycemia. This was a retrospective study of hospitalized patients receiving intravenous insulin for hyperkalemia during a 6-month period. Patients with low eGFR were analyzed based on how much insulin they received: high dose (10 units, n = 78) versus low dose (5 units, n = 71). Postdose nadir blood glucose values were examined for up to 8 hours after the dose. The percentage of hypoglycemia (blood glucose ≤70 mg/dl) and a subset of severe hypoglycemia (blood glucose <50 mg/dl) were then reported for each dose group. A total of 149 doses were identified in patients with low eGFR. The rates of hypoglycemia were 16.7% and 19.7% (P = 0.79), respectively, among high-dose (n = 78) and low-dose (n = 71) groups. Rates of severe hypoglycemia were 8.9% and 7.0%, respectively (P = 0.90). More than 28% of hypoglycemic episodes with high doses occurred after 4 hours (median = 2.5 hours) compared with 14.3% with low doses (median = 2.38 hours). There was no difference in the rate of hypoglycemia or severe hypoglycemia between high or low doses of insulin in patients with low eGFR. We recommend monitoring up to 6 hours after insulin use in hyperkalemia. © The Author(s) 2015.
Hauser, Robert A; Slawek, Jaroslaw; Barone, Paolo; Dohin, Elisabeth; Surmann, Erwin; Asgharnejad, Mahnaz; Bauer, Lars
2016-06-07
This multicenter, double-blind, placebo-controlled study assessed the efficacy of rotigotine transdermal patch on apathy and motor symptoms in patients with Parkinson's disease (PD). Patients with PD-associated apathy (Unified Parkinson's Disease Rating Scale [UPDRS] I item 4 [motivation] ≥2 and patient-rated Apathy Scale [AS] ≥14) were randomized 1:1:1 to "low-dose" rotigotine (≤6 mg/24 h for early PD [those not receiving levodopa] or ≤8 mg/24 h for advanced PD [those receiving levodopa]), "high-dose" rotigotine (≤8 mg/24 h for early PD or ≤16 mg/24 h for advanced PD), or placebo, and maintained at optimal/maximal dose for 12 weeks. Coprimary efficacy variables were: change from baseline to End of Maintenance in patient-rated AS and UPDRS II + III total score. Recruitment was stopped after an interim futility analysis; therefore, all p values are exploratory. Of 122 patients randomized, 81.1 % completed the study (placebo, n = 32/40 [80.0 %]; low-dose rotigotine, n = 30/41 [73.2 %]; high-dose rotigotine, n = 37/41 [90.2 %]). No treatment difference was observed in the change in patient-rated AS (least squares mean [95 % confidence interval (CI)] difference: low-dose, 0.04 [-2.42, 2.50], p =0.977; high-dose, -0.22 [-2.61, 2.18], p = 0.859). Rotigotine improved UPDRS II + III total scores versus placebo (least squares mean [95 % CI] treatment difference: low-dose, -7.29 [-12.30, -2.28], p = 0.005; high-dose, -6.06 [-10.90, -1.21], p = 0.015), and the "mood/apathy" domain of the Non-Motor Symptom Scale as rated by the investigator (secondary outcome). The most frequent adverse events in rotigotine-treated patients were application site reactions, somnolence, and nausea. Rotigotine did not improve PD-associated apathy as rated by the patient but provided clinically relevant improvement in motor control and activities of daily living. ClinicalTrials.gov identifier NCT01782222 . Trial registration date: January 30, 2013.
Uckun, Fatih M.; Myers, Dorothea E.; Ma, Hong; Rose, Rebecca; Qazi, Sanjive
2015-01-01
In high-risk remission B-precursor acute lymphoblastic leukemia (BPL) patients, relapse rates have remained high post-hematopoietic stem cell transplantation (HSCT) even after the use of very intensive total body irradiation (TBI)-based conditioning regimens, especially in patients with a high “minimal residual disease” (MRD) burden. New agents capable of killing radiation-resistant BPL cells and selectively augmenting their radiation sensitivity are therefore urgently needed. We report preclinical proof-of-principle that the potency of radiation therapy against BPL can be augmented by combining radiation with recombinant human CD19-Ligand × soluble TRAIL (“CD19L–sTRAIL”) fusion protein. CD19L–sTRAIL consistently killed radiation-resistant primary leukemia cells from BPL patients as well as BPL xenograft cells and their leukemia-initiating in vivo clonogenic fraction. Low dose total body irradiation (TBI) combined with CD19L–sTRAIL was highly effective against (1) xenografted CD19+ radiochemotherapy-resistant human BPL in NOD/SCID (NS) mice challenged with an otherwise invariably fatal dose of xenograft cells derived from relapsed BPL patients as well as (2) radiation-resistant advanced stage CD19+ murine BPL with lymphomatous features in CD22ΔE12xBCR-ABL double transgenic mice. We hypothesize that the incorporation of CD19L–sTRAIL into the pre-transplant TBI regimens of patients with very high-risk BPL will improve their survival outcome after HSCT. PMID:26097891
High-dose transdermal nicotine replacement for tobacco cessation.
Brokowski, Laurie; Chen, Jiahui; Tanner, Sara
2014-04-15
The safety and efficacy of high-dose transdermal nicotine-replacement therapy (NRT) for the treatment of tobacco-use cessation were reviewed. Transdermal nicotine doses of 7, 14, and 21 mg daily are approved by the Food and Drug Administration for use in tobacco cessation. However, studies have suggested that these doses are more adequate for people who smoke fewer than 20 cigarettes per day. A literature search was conducted to identify English-language studies that evaluated the use of transdermal nicotine doses of ≥42 mg daily. A total of 11 articles were identified, representing 10 separate trials. In terms of safety, the majority of the trials had no reports of serious adverse events related to transdermal NRT at doses of ≥42 mg daily. A dose-response relationship with adverse events occurred in most trials. In terms of efficacy, a numerically higher abstinence rate was achieved with high-dose transdermal NRT in all trials but 1. However, none of the studies showed significant differences in final abstinence rates at follow-up. Some reasons why statistical significance was not achieved in these trials may be related to the limitations of these trials, such as their small samples and the lack of a power calculation. A more robust trial is needed to support higher nicotine transdermal doses in tobacco cessation and to help elucidate which patient population would be most suitable for their use. The safety and efficacy of high-dose transdermal NRT for tobacco cessation have not been established in the medical literature.
α-Lipoic acid reduced weight gain and improved the lipid profile in rats fed with high fat diet.
Seo, Eun Young; Ha, Ae Wha; Kim, Woo Kyoung
2012-06-01
The purpose of this study was to investigate the effects of α-lipoic acid on body weight and lipid profiles in Sprague-Dawley rats fed a high fat diet (HFD). After 4 weeks of feeding, rats on the HFD were divided into three groups by randomized block design; the first group received the high-fat-diet (n = 10), and the second group received the HFD administered with 0.25% α-lipoic acid (0.25LA), and the third group received the high-fat diet with 0.5% α-lipoic acid (0.5LA). The high fat diet with α-lipoic acid supplemented groups had significantly inhibited body weight gain, compared to that in the HFD group (P < 0.05). Organ weights of rats were also significantly reduced in liver, kidney, spleen, and visible fat tissues in rats supplemented with α-lipoic acid (P < 0.05). Significant differences in plasma lipid profiles, such as total lipids, total cholesterol, triglycerides, low-density lipoprotein, and high-density lipoprotein, were observed between the HFD and 0.5LA groups. The atherogenic index and the plasma high density lipoprotein-cholesterol/total cholesterol ratio improved significantly with α-lipoic acid supplementation in a dose-dependent manner (P < 0.05). Total hepatic cholesterol and total lipid concentration decreased significantly in high fat fed rats supplemented with α-lipoic acid in a dose-dependent manner (P < 0.05), whereas liver triglyceride content was not affected. In conclusion, α-lipoic acid supplementation had a positive effect on weight gain and plasma and liver lipid profiles in rats.
Glucuronidation and Sulfation Kinetics of Diflunisal in Man.
NASA Astrophysics Data System (ADS)
Loewen, Gordon Rapheal
Diflunisal is a nonsteroidal anti-inflammatory drug used in the treatment of arthritis and musculoskeletal pain. Diflunisal exhibits concentration- and dose-dependent kinetics, the mechanism of which has not been determined. The purpose of this study was to determine the mechanism(s) responsible for non-linear disposition of diflunisal and to examine environmental factors which may affect the elimination of diflunisal. The metabolites of diflunisal, including a new metabolite, the sulphate conjugate, were purified by column and semi-preparative high pressure liquid chromatography. Assays for the quantitation of diflunisal and conjugates in urine and diflunisal in plasma were developed. Plasma protein binding of diflunisal in blank plasma and in plasma obtained following multiple doses of diflunisal was determined by equilibrium dialysis. Total body clearance of diflunisal decreased when dose increased from 100 to 750 mg. Total clearance increased when dose increased from 750 to 1000 mg. The percent of recovered dose eliminated as the acyl glucuronide decreased and the percent eliminated as the sulphate increased with increasing dose of diflunisal. Plasma protein binding of diflunisal was concentration dependent over a range of diflunisal plasma concentrations of 3 to 257 mug/ml. Total clearance, and to a lesser degree, unbound clearance of diflunisal were decreased following multiple dose administration of 250 and 500 mg diflunisal. Percent of recovered dose eliminated as the acyl glucuronide decreased and percent eliminated as the sulphate conjugate increased following multiple dosing. Plasma protein binding of diflunisal was similar in blank plasma and plasma obtained at steady state. Unbound clearance of diflunisal exceeded liver plasma flow. Frequency distributions of the elimination of the conjugates of diflunisal were normally distributed. Sex, smoking, and use of vitamins or oral contraceptives were identified as factors which may affect the elimination of diflunisal.
Werumeus Buning, Jorien; Touw, Daan J; Brummelman, Pauline; Dullaart, Robin P F; van den Berg, Gerrit; van der Klauw, Melanie M; Kamp, Jasper; Wolffenbuttel, Bruce H R; van Beek, André P
2017-06-01
This study aimed at comparing pharmacokinetics of two different doses of hydrocortisone (HC) in patients with secondary adrenal insufficiency (SAI). Forty-six patients with SAI participated in this randomized double-blind crossover study. Patients received two different doses of HC (0.2-0.3mg HC/kg body weight/day and 0.4-0.6mg HC/kg body weight/day). One- and two-compartment population models for plasma free cortisol, plasma total cortisol and salivary cortisol were parameterized. The individual pharmacokinetic parameters clearance (CL), volume of distribution (V d ), elimination half-life (t 1/2 ), maximum concentration (C max ), and area under the curve (AUC) were calculated. The one-compartment models gave a better description of the data compared to the two-compartment models. Weight-adjusted dosing reduced variability in cortisol exposure with comparable AUCs between weight groups. However, there was large inter-individual variation in CL and V d of plasma free cortisol, plasma total cortisol and salivary cortisol. As a consequence, AUC 24h varied more than 10 fold. Cortisol exposure was increased with the higher dose, but this was dose proportional only for free cortisol concentrations and not for total cortisol. Cortisol concentrations after a doubling of the dose were only dose proportional for free cortisol. HC pharmacokinetics can differ up to 10-fold inter-individually and individual adjustment of treatment doses may be necessary. Doubling of the HC dose in fast metabolizers (patients that showed relative low AUC and thus high clearance compared to other patients), does not result in significantly enhanced exposure during large parts of the day and these patients may need other management strategies. Copyright © 2017 Elsevier Inc. All rights reserved.
Changes in Neuropsychiatric Inventory Associated with Semagacestat Treatment of Alzheimer's Disease.
Rosenberg, Paul B; Lanctôt, Krista L; Herrmann, Nathan; Mintzer, Jacobo E; Porsteinsson, Anton P; Sun, Xiaoying; Raman, Rema
2016-08-10
In a recent report, 76 weeks' treatment with a gamma-secretase inhibitor (semagacestat) was associated with poorer cognitive outcomes in Alzheimer's disease (AD). We sought to examine the effect of semagacestat treatment on neuropsychiatric symptoms (NPS). 1,537 participants with mild to moderate AD were randomized to 76 weeks' treatment with placebo versus two doses of semagacestat. NPS were assessed with the Neuropsychiatric Inventory (NPI-Total and subdomains). Cognition was assessed with the Alzheimer's Disease Assessment Scale-Cognitive (first 11 items, ADAS11). Mixed-Model Repeated Measures was used to compare the effects of treatment assignment on change in NPI-total and subdomains over time. Survival analysis was used to assess the treatment effect on time to first worsening of NPS (NPI-Total ≥10 or NPI subdomain ≥4) for subjects with no or minor NPS at baseline. Participants on high dose semagecestat (140 mg) had greater increase in NPI-Total and greater risk of incident first worsening in NPI-Total and in subdomains of aberrant motor behavior, appetite, depression/dysphoria, and sleep. ADAS11 increased more in participants whose NPI-Total increased. In participants with mild to moderate AD, high dose semagacestat treatment was associated with greater severity and faster worsening of NPS in a pattern resembling an agitated depression. Increased NPS was associated with cognitive decline regardless of treatment assignment. These findings suggest that greater NPS may be the result of gamma-secretase treatment and emphasize the importance of monitoring NPS as potential adverse events in trials of novel treatments for AD.
Janković Mandić, Ljiljana; Đolić, Maja; Marković, Dragana; Todorović, Dragana; Onjia, Antonije; Dragović, Snežana
2016-01-01
The activity concentrations of natural radionuclides ((40)K, (210)Pb, (210)Po, (226)Ra and (228)Ra) in 17 most frequently used cigarette brands in Serbia and corresponding effective doses due to smoke inhalation are presented. The mean annual effective doses for (210)Pb and (210)Po were estimated to be 47.3 and 724 µSv y(-1) for (210)Pb and (210)Po, respectively. Serbia currently has the highest smoking rate in the world. The results of this study indicate the high contribution of the annual effective dose due to smoke inhalation to the total inhalation dose from natural radionuclides. The more effective implementation of actions for reducing smoking prevalence in Serbia is highly needed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Akatov YuA; Arkhangelsky, V V; Kovalev, E E; Spurny, F; Votochkova, I
1989-01-01
In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.
Study of runaway electrons using dosimetry of hard x-ray radiations in Damavand tokamak
NASA Astrophysics Data System (ADS)
Rasouli, C.; Pourshahab, B.; Hosseini Pooya, S. M.; Orouji, T.; Rasouli, H.
2014-05-01
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method. The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components. Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points - three TLDs per point - to map hard x-ray radiation doses on the exterior of the vacuum vessel. Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel. The low-dose area on which measured dose is about 0.5 mSv/shot. In the low-dose area there is no particular component inside the vessel. On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot. The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections. Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons. Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.
Study of runaway electrons using dosimetry of hard x-ray radiations in Damavand tokamak.
Rasouli, C; Pourshahab, B; Hosseini Pooya, S M; Orouji, T; Rasouli, H
2014-05-01
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method. The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components. Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points--three TLDs per point--to map hard x-ray radiation doses on the exterior of the vacuum vessel. Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel. The low-dose area on which measured dose is about 0.5 mSv/shot. In the low-dose area there is no particular component inside the vessel. On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot. The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections. Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons. Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.
NASA Astrophysics Data System (ADS)
Caridi, F.; Marguccio, S.; Durante, G.; Trozzo, R.; Fullone, F.; Belvedere, A.; D'Agostino, M.; Belmusto, G.
2017-01-01
In this article natural radioactivity measurements and dosimetric evaluations in soil samples contaminated by Naturally Occurring Radioactive Materials (NORM) are made, in order to assess any possible radiological hazard for the population and for workers professionally exposed to ionizing radiations. Investigated samples came from the district of Crotone, Calabria region, South of Italy. The natural radioactivity investigation was performed by high-resolution gamma-ray spectrometry. From the measured gamma spectra, activity concentrations were determined for 226Ra , 234-mPa , 224Ra , 228Ac and 40K and compared with their clearance levels for NORM. The total effective dose was calculated for each sample as due to the committed effective dose for inhalation and to the effective dose from external irradiation. The sum of the total effective doses estimated for all investigated samples was compared to the action levels provided by the Italian legislation (D.Lgs.230/95 and subsequent modifications) for the population members (0.3mSv/y) and for professionally exposed workers (1mSv/y). It was found to be less than the limit of no radiological significance (10μSv/y).
Liu, Yue-E; Lin, Qiang; Meng, Fan-Jie; Chen, Xue-Ji; Ren, Xiao-Cang; Cao, Bin; Wang, Na; Zong, Jie; Peng, Yu; Ku, Ya-Jun; Chen, Yan
2013-08-11
Increasing the radiotherapy dose can result in improved local control for non-small-cell lung cancer (NSCLC) and can thereby improve survival. Accelerated hypofractionated radiotherapy can expose tumors to a high dose of radiation in a short period of time, but the optimal treatment regimen remains unclear. The purpose of this study was to evaluate the feasibility of utilizing high-dose accelerated hypofractionated three-dimensional conformal radiotherapy (at 3 Gy/fraction) with concurrent vinorelbine (NVB) and carboplatin (CBP) chemotherapy for the treatment of local advanced NSCLC. Untreated patients with unresectable stage IIIA/IIIB NSCLC or patients with a recurrence of NSCLC received accelerated hypofractionated three-dimensional conformal radiotherapy. The total dose was greater than or equal to 60 Gy. The accelerated hypofractionated radiotherapy was conducted once daily at 3 Gy/fraction with 5 fractions per week, and the radiotherapy was completed in 5 weeks. In addition to radiotherapy, the patients also received at least 1 cycle of a concurrent two-drug chemotherapy regimen of NVB and CBP. A total of 26 patients (19 previously untreated cases and 7 cases of recurrent disease) received 60Gy-75Gy radiotherapy with concurrent chemotherapy. All of the patients underwent evaluations for toxicity and preliminary therapeutic efficacy. There were no treatment-related deaths within the entire patient group. The major acute adverse reactions were radiation esophagitis (88.5%) and radiation pneumonitis (42.3%). The percentages of grade III acute radiation esophagitis and grade III radiation pneumonitis were 15.4% and 7.7%, respectively. Hematological toxicities were common and did not significantly affect the implementation of chemoradiotherapy after supportive treatment. Two patients received high dose of 75 Gy had grade III late esophageal toxicity, and none had grade IV and above. Grade III and above late lung toxicity did not occur. High-dose accelerated hypofractionated three-dimensional conformal radiotherapy with a dose of 60 Gy or greater with concurrent NVB and CBP chemotherapy might be feasible. However esophagus toxicity needs special attention. A phase I trial is recommended to obtain the maximum tolerated radiation dose of accelerated hypofractionated radiotherapy with concurrent chemotherapy.
2013-01-01
Background Increasing the radiotherapy dose can result in improved local control for non-small-cell lung cancer (NSCLC) and can thereby improve survival. Accelerated hypofractionated radiotherapy can expose tumors to a high dose of radiation in a short period of time, but the optimal treatment regimen remains unclear. The purpose of this study was to evaluate the feasibility of utilizing high-dose accelerated hypofractionated three-dimensional conformal radiotherapy (at 3 Gy/fraction) with concurrent vinorelbine (NVB) and carboplatin (CBP) chemotherapy for the treatment of local advanced NSCLC. Methods Untreated patients with unresectable stage IIIA/IIIB NSCLC or patients with a recurrence of NSCLC received accelerated hypofractionated three-dimensional conformal radiotherapy. The total dose was greater than or equal to 60 Gy. The accelerated hypofractionated radiotherapy was conducted once daily at 3 Gy/fraction with 5 fractions per week, and the radiotherapy was completed in 5 weeks. In addition to radiotherapy, the patients also received at least 1 cycle of a concurrent two-drug chemotherapy regimen of NVB and CBP. Results A total of 26 patients (19 previously untreated cases and 7 cases of recurrent disease) received 60Gy-75Gy radiotherapy with concurrent chemotherapy. All of the patients underwent evaluations for toxicity and preliminary therapeutic efficacy. There were no treatment-related deaths within the entire patient group. The major acute adverse reactions were radiation esophagitis (88.5%) and radiation pneumonitis (42.3%). The percentages of grade III acute radiation esophagitis and grade III radiation pneumonitis were 15.4% and 7.7%, respectively. Hematological toxicities were common and did not significantly affect the implementation of chemoradiotherapy after supportive treatment. Two patients received high dose of 75 Gy had grade III late esophageal toxicity, and none had grade IV and above. Grade III and above late lung toxicity did not occur. Conclusion High-dose accelerated hypofractionated three-dimensional conformal radiotherapy with a dose of 60 Gy or greater with concurrent NVB and CBP chemotherapy might be feasible. However esophagus toxicity needs special attention. A phase I trial is recommended to obtain the maximum tolerated radiation dose of accelerated hypofractionated radiotherapy with concurrent chemotherapy. PMID:23937855
[Foshouningshen decoction improves sleeping via the serotonergic system in a rat model of insomnia].
Huang, Jie-Cong; Xie, Wei; Deng, Ning; Liang, Wen-Lin; Hu, Dong-Rong; Hong, Yu; Zhou, Yang
2017-08-20
To evaluate the sedative and hypnotic effects of Foshouningshen decoction (FSNSD) and study its effects on expressions of 5-hydroxy tryptamine (5-HT) and 5-HT1A receptor (5-HT 1A R) in the hippocampus in a rat model of insomnia. Male KM mice were divided into control group, estazolam (0.4 mg/kg daily) group, and low-, moderate-, and high-dose FSNSD groups (daily dose of 12, 24, and 48 g/kg, respectively). After corresponding treatments for 1 week, the mice underwent sleep-inducing test with subthreshold and threshold doses of sodium pentobarbital. Forty-eight male SD rats were randomized into control group, insomnia model group, estazolam group (0.2 mg/kg daily), and low-, moderate-, and high-dose FSNSD groups (with daily dose of 6, 12, and 24 g/kg, respectively). Rat models of insomnia were established by intraperitoneal injection of 4-cholro-dl-phenylalanine (PCPA) at the daily dose of 350 mg/kg for 3 days, after which the rats received corresponding treatments via gavage for 1 week. The performance of the rats in open field test was recorded and the hippocampal expression of 5-HT was detected using ELISA; the expressions of 5-HT 1A R protein and mRNA in the hippocampus were detected using immunohistochemistry and real-time PCR, respectively. In the sleep-inducing test with a subthreshold dose of sodium pentobarbital, the mice treated with high-dose FSNSD showed a significantly higher rate of sleep onset than the control mice (P<0.05); in the test with a threshold dose of sodium pentobarbital, treatment with moderate- and high-dose FSNSD resulted in significantly prolonged sleeping time (P<0.01) and shortened sleep latency (P<0.05) in the mice. The rats in insomnia model group showed increased total distance in open field test (P<0.05) with significantly decreased content of 5-HT (P<0.01) and expressions of 5-HT 1A R protein and mRNA in the hippocampus (P<0.01). Treatment of the rats with estazolam or high-dose FSNSD obviously decreased the total distance in open field test (P<0.05) and increased the content of 5-HT (P<0.05) and expressions of 5-HT 1A R (P<0.01) in the hippocampus of rats with insomnia. FSNSD can produce therapeutic effects on insomnia possibly by increasing 5-HT content and expressions of 5-HT 1A R in the hippocampus.
The space radiation environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robbins, D E
There are three primary sources of space radiation: galactic cosmic rays (GCR), trapped belt radiation, and solar particle events (SPE). All are composed of ions, the nuclei of atoms. Their energies range from a few MeV u{sup -1} to over a GeV u{sup -1}. These ions can fragment when they interact with spacecraft materials and produce energetic neutrons and ions of lower atomic mass. Absorbed dose rates inside a typical spacecraft (like the Space Shuttle) in a low inclination (28.5 degrees) orbit range between 0.05 and 2 mGy d{sup -1} depending on the altitude and flight inclination (angle of orbitmore » with the equator). The quality factor of radiation in orbit depends on the relative contributions of trapped belt radiation and GCR, and the dose rate varies both with orbital altitude and inclination. The corresponding equivalent dose rate ranges between 0.1 and 4 mSv d{sup -1}. In high inclination orbits, like that of the Mir Space Station and as is planned for the International Space Station, blood-forming organ (BFO) equivalent dose rates as high as 1.5 mSv d{sup -1}. Thus, on a 1 y mission, a crew member could obtain a total dose of 0.55 Sv. Maximum equivalent dose rates measured in high altitude passes through the South Atlantic Anomaly (SAA) were 10 mSv h{sup -1}. For an interplanetary space mission (e.g., to Mars) annual doses from GCR alone range between 150 mSv y{sup -1} at solar maximum and 580 mSv y{sup -1} at solar minimum. Large SPE, like the October 1989 series, are more apt to occur in the years around solar maximum. In free space, such an event could contribute another 300 mSv, assuming that a warning system and safe haven can be effectively used with operational procedures to minimize crew exposures. Thus, the total dose for a 3 y mission to Mars could exceed 2 Sv.« less
Angevin, Eric; Spitaleri, Gianluca; Rodon, Jordi; Dotti, Katia; Isambert, Nicolas; Salvagni, Stefania; Moreno, Victor; Assadourian, Sylvie; Gomez, Corinne; Harnois, Marzia; Hollebecque, Antoine; Azaro, Analia; Hervieu, Alice; Rihawi, Karim; De Marinis, Filippo
2017-12-01
Dysregulated MET signalling is implicated in oncogenesis. The safety and preliminary efficacy of a highly selective MET kinase inhibitor (SAR125844) was investigated in patients with advanced solid tumours and MET dysregulation. This was a phase I dose-escalation (3 + 3 design [50-740 mg/m 2 ]) and dose-expansion study. In the dose escalation, patients had high total MET (t-MET) expression by immunohistochemistry (IHC) or MET amplification by fluorescence in situ hybridisation. In the dose expansion, patients had MET amplification (including a subset of patients with non-small cell lung cancer [NSCLC]) or phosphorylated-MET (p-MET) expression (IHC). Objectives were determination of maximum tolerated dose (MTD) of once-weekly intravenous SAR125844 based on dose-limiting toxicities; safety and pharmacokinetic profile; preliminary efficacy of SAR125844 MTD in the expansion cohort. In total, 72 patients were enrolled: dose escalation, N = 33; dose expansion, N = 39; 570 mg/m 2 was established as the MTD. Most frequent treatment-emergent adverse events (AEs) were asthenia/fatigue (58.3%), nausea (31.9%), and abdominal pain, constipation, and dyspnea (27.8% for each); 58.3% of patients reported grade 3 AEs (19.4% were treatment related). Of the 29 evaluable patients with MET amplification treated at 570 mg/m 2 , five achieved a partial response, including four of 22 with NSCLC; 17 patients had stable disease. No response was observed in patients with high p-MET solid tumours. There was no correlation between tumour response and t-MET status or MET gene copy number. The MTD of once-weekly SAR125844 was 570 mg/m 2 ; SAR125844 was well tolerated, with significant antitumour activity in patients with MET-amplified NSCLC. NCT01391533. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Soy food intake and risk of gastric cancer: A dose-response meta-analysis of prospective studies.
Weng, Ke-Gui; Yuan, Ya-Ling
2017-08-01
Epidemiological studies were inconsistent on the association between soy food intake and risk of gastric cancer (GC). This study aimed to determine the role of soy food intake in the development of GC.A systematic search was conducted in PubMed and Web of Science to identify all relevant studies. Study-specific relative risks (RRs) and 95% confidence intervals (CIs) were pooled using a random-effects model, and the dose-response relationship between soy food intake and GC risk was also assessed.Thirteen prospective studies were identified with a total of 517,106 participants and 5800 cases. Among 11 types of soy food, high intake of total soy food (the highest vs the lowest category: RR: 0.78, 95% CI: 0.62-0.98) and nonfermented soy food (RR: 0.63, 95% CI: 0.50-0.79) were inversely associated with GC risk, while high intake of miso soup was associated with the risk in male (RR: 1.17, 95% CI: 1.02-1.36). In dose-response meta-analysis, total soy food intake (0-150 g/day) showed no significant association with GC risk, while high intake of nonfermented soy food was inversely related, especially an intake of more than 100 g/day. In male, miso soup intake (1-5 cups/day) was significantly associated with GC risk.High intake of nonfermented soy food might reduce the risk of GC, while miso soup intake might increase the risk in male.
NASA Astrophysics Data System (ADS)
van Vonno, N. W.; White, J. D.; Pearce, L. G.; Thomson, E. J.; Gill, J. S.; Mansilla, O. E.
2014-08-01
Single-event transient (SET) phenomena in power management applications has evolved into a key issue, particularly in point of load (POL) buck regulators, as the loads driven by these devices are sensitive to even short-term overvoltage conditions. We preface this paper by a discussion of earlier destructive and nondestructive SEE testing of Intersil integrated point of load regulators, with emphasis on SET phenomena and some of the lessons learned in this work. We then report recent results of SET and destructive SEE testing of the ISL70003SEH POL converter, together with a brief discussion of the part's electrical and radiation hardness specifications. We conclude with a brief overview of low and high dose rate total dose testing of the part.
Roberts, J A; Stove, V; De Waele, J J; Sipinkoski, B; McWhinney, B; Ungerer, J P J; Akova, M; Bassetti, M; Dimopoulos, G; Kaukonen, K-M; Koulenti, D; Martin, C; Montravers, P; Rello, J; Rhodes, A; Starr, T; Wallis, S C; Lipman, J
2014-05-01
The aims of this study were to describe the variability in protein binding of teicoplanin in critically ill patients as well as the number of patients achieving therapeutic target concentrations. This report is part of the multinational pharmacokinetic DALI Study. Patients were sampled on a single day, with blood samples taken both at the midpoint and the end of the dosing interval. Total and unbound teicoplanin concentrations were assayed using validated chromatographic methods. The lower therapeutic range of teicoplanin was defined as total trough concentrations from 10 to 20 mg/L and the higher range as 10-30 mg/L. Thirteen critically ill patients were available for analysis. The following are the median (interquartile range) total and free concentrations (mg/L): midpoint, total 13.6 (11.2-26.0) and free 1.5 (0.7-2.5); trough, total 11.9 (10.2-22.7) and free 1.8 (0.6-2.6). The percentage free teicoplanin for the mid-dose and trough time points was 6.9% (4.5-15.6%) and 8.2% (5.5-16.4%), respectively. The correlation between total and free antibiotic concentrations was moderate for both the midpoint (ρ = 0.79, P = 0.0021) and trough (ρ = 0.63, P = 0.027). Only 42% and 58% of patients were in the lower and higher therapeutic ranges, respectively. In conclusion, use of standard dosing for teicoplanin leads to inappropriate concentrations in a high proportion of critically ill patients. Variability in teicoplanin protein binding is very high, placing significant doubt on the validity of total concentrations for therapeutic drug monitoring in critically ill patients. Copyright © 2014 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus
2009-01-01
In organ grafts donor-specific sensitization is initiated immediately after revascularization. Therefore, in 1990 we introduced the intra-operative single high-dose ATG-Fresenius (ATG-F) induction in addition to standard triple drug therapy (TDT) consisting of steroids, azathioprine and cyclosporin. A total of 778 first renal transplantations from deceased donors, performed between 1987 and 1998, were included in this evaluation. This retrospective analysis of clinic records and electronic databases presents data of all recipients of first kidney grafts who received two different ATG-F inductions (1(st) group: 9 mg/kg body weight as single high-dose intra-operatively, n=484; 2(nd) group: 3 mg/kg body weight on 7 or 8 consecutive days as multiple-dose starting also intra-operatively, n=78) and standard TDT alone (3(rd) group: TDT alone, n=216). The 10-year patient survival rates were 72.6+/-2.6% (TDT + ATG-F single high-dose), 79.5+/-5.1% (TDT + ATG-F multiple-dose) and 67.2+/-3.7%% (TDT alone; Kaplan-Meier estimates with standard errors; ATG-F vs TDT alone, p=0.001). The 10-year graft survival rates with censoring of patients that died with a functioning graft were 73.8+/-2.4%, 57.7+/-5.8% and 58.4+/-3.6% (Kaplan-Meier estimates with standard errors; 1(st) vs 2(nd )and 3(rd) group, respectively, p<0.001) and the 10-year graft survival rates with patient death counted as graft failure were 58.3+/-2.7%, 55.7+/-5.8% and 48.2+/-3.5% (Kaplan-Meier estimates with standard errors; ATG-F single high-dose vs TDT, p=0.023). In pre-sensitized recipients there were also significant differences in favour of ATG-F, more notably in the single high-dose ATG-F induction. A total of 69% of the patients in the two cohorts receiving ATG-F did not experience any transplant rejections compared to 56% in patients undergoing TDT alone (p=0.018). The incidence of infectious complications was comparable across all groups. According to evidence obtained from the routine documentation of 778 renal transplantations, ATG-F induction therapy administered as a part of immunosuppressive therapy significantly improves patient survival and reduces the risk of graft failure and transplant rejections.
Head and neck tumors after energetic proton irradiation in rats
NASA Astrophysics Data System (ADS)
Wood, D.; Cox, A.; Hardy, K.; Salmon, Y.; Trotter, R.
1994-10-01
This is a two-year progress report on a life span dose-response study of brain tumor risk at moderate to high doses of energetic protons. It was initiated because a joint NASA/USAF life span study of rhesus monkeys that were irradiated with 55-MeV protons (average surface dose, 3.5 Gy) indicated that the incidence of brain tumors per unit surface absorbed dose was over 19 times that of the human tinea capitis patients whose heads were exposed to 100 kv x-rays. Examination of those rats that died in the two-year interval after irradiation of the head revealed a linear dose-response for total head and neck tumor incidence in the dose range of 0-8.5 Gy. The exposed rats had a greater incidence of pituitary chromophobe adenomas, epithelial and mesothelial cell tumors than the unexposed controls but the excessive occurrence of malignant gliomas that was observed in the monkeys was absent in the rats. The estimated dose required to double the number of all types of head and neck tumors was 5.2 Gy. The highest dose, 18 Gy, resulted in high mortality due to obstructive squamous metaplasia at less than 50 weeks, prompting a new study of the relative bological effectiveness of high energy protons in producing this lesion.
High Dose Hyperfractionated Radiotherapy for Adults with Glioblastomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koukourakis, Michael; Scarlatos, John; Yiannakakis, Dimitrios
2015-01-15
From 1989 to 1991, 27 patients with glioblastoma multiforme or anaplastic astrocytoma of the brain were treated with radiotherapy. Fifteen of twenty-seven patients were treated through limited volume fields, with a thrice-a-day (1.1 Gy/f) or twice-a-day (1.4 Gy/f) hyperfractionated regimen to a total physical dose of 62–92 Gy (median dose 76 Gy). The remaining 12 were treated with whole brain irradiation (40 Gy of total conventionally fractionated dose) and a localised boost to a total dose of 60 Gy. The hyperfractionated regimen was well tolerated and there was no sign of increased brain oedema to indicate the insertion of amore » split. Of six patients who received a NTD10 (normalised total dose for α/β =10) higher than 71 Gy, five showed CR (83% CR rate) versus three of 21 patients who received a lower NTD10 (14% CR rate). For 13 patients who received a NTD10 higher than 66 Gy, the 18-months survival was 61% (8/13) versus 28% (4/14) for 14 patients who received a NTD10 less than 66 Gy. As far as the late morbidity is concerned, of six patients treated with 76-92 Gy of physical dose, none died because of radiation-induced brain necrosis within 18-42 months of follow-up, and three of them are without evidence of disease 18-31 months after the end of radiation treatment. None of our 15 patients who received less than whole brain irradiation relapsed outside the radiation portals. The present study strongly suggests the use of limited volume hyperfractionated radiotherapy schemes, so as to increase the local tumor dose (NTD10) to values higher than 79 Gy, at the same time keeping the NTD2 (NTD for α/β = 2) below 68 Gy.« less
SU-E-J-124: 18F-FDG PET Imaging to Improve RT Treatment Outcome for Locally Advanced Lung Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shusharina, N; Khan, F; Sharp, G
2015-06-15
Purpose: To investigate spatial correlation between high uptake regions of pre- and 10-days-post therapy{sup 1} {sup 8}F-FDG PET in recurrent lung cancer and to evaluate the feasibility of dose escalation boosting only regions with high FDG uptake identified on baseline PET. Methods: Nineteen patients with stages II– IV inoperable lung cancer were selected. Volumes of interest (VOI) on pre-therapy FDG-PET were defined using an isocontour at ≥50% of SUVmax. VOI of pre- and post-therapy PET images were correlated for the extent of overlap. A highly optimized IMRT plan to 60 Gy prescribed to PTV defined on the planning CT wasmore » designed using clinical dose constraints for the organs at risk. A boost of 18 Gy was prescribed to the VOI defined on baseline PET. A composite plan of the total 78 Gy was compared with the base 60 Gy plan. Increases in dose to the lungs, spinal cord and heart were evaluated. IMRT boost plan was compared with proton RT and SBRT boost plans. Results: Overlap fraction of baseline PET VOI with the VOI on 10 days-post therapy PET was 0.8 (95% CI: 0.7 – 0.9). Using baseline VOI as a boosting volume, dose could be escalated to 78 Gy for 15 patients without compromising the dose constraints. For 4 patients, the dose limiting factors were V20Gy and Dmean for the total lung, and Dmax for the spinal cord. An increase of the dose to OARs correlated significantly with the relative size of the boost volume. Conclusion: VOI defined on baseline 18F-FDG PET by the SUVmax-≥50% isocontour may be a biological target volume for escalated radiation dose. Dose escalation to this volume may provide improved tumor control without breaching predefined dose constraints for OARs. The best treatment outcome may be achieved with proton RT for large targets and with SBRT for small targets.« less
Do fungi need to be included within environmental radiation protection assessment models?
Guillén, J; Baeza, A; Beresford, N A; Wood, M D
2017-09-01
Fungi are used as biomonitors of forest ecosystems, having comparatively high uptakes of anthropogenic and naturally occurring radionuclides. However, whilst they are known to accumulate radionuclides they are not typically considered in radiological assessment tools for environmental (non-human biota) assessment. In this paper the total dose rate to fungi is estimated using the ERICA Tool, assuming different fruiting body geometries, a single ellipsoid and more complex geometries considering the different components of the fruit body and their differing radionuclide contents based upon measurement data. Anthropogenic and naturally occurring radionuclide concentrations from the Mediterranean ecosystem (Spain) were used in this assessment. The total estimated weighted dose rate was in the range 0.31-3.4 μGy/h (5 th -95 th percentile), similar to natural exposure rates reported for other wild groups. The total estimated dose was dominated by internal exposure, especially from 226 Ra and 210 Po. Differences in dose rate between complex geometries and a simple ellipsoid model were negligible. Therefore, the simple ellipsoid model is recommended to assess dose rates to fungal fruiting bodies. Fungal mycelium was also modelled assuming a long filament. Using these geometries, assessments for fungal fruiting bodies and mycelium under different scenarios (post-accident, planned release and existing exposure) were conducted, each being based on available monitoring data. The estimated total dose rate in each case was below the ERICA screening benchmark dose, except for the example post-accident existing exposure scenario (the Chernobyl Exclusion Zone) for which a dose rate in excess of 35 μGy/h was estimated for the fruiting body. Estimated mycelium dose rate in this post-accident existing exposure scenario was close to the 400 μGy/h benchmark for plants, although fungi are generally considered to be less radiosensitive than plants. Further research on appropriate mycelium geometries and their radionuclide content is required. Based on the assessments presented in this paper, there is no need to recommend that fungi should be added to the existing assessment tools and frameworks; if required some tools allow a geometry representing fungi to be created and used within a dose assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Charge Yield at Low Electric Fields: Considerations for Bipolar Integrated Circuits
NASA Technical Reports Server (NTRS)
Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.
2013-01-01
A significant reduction in total dose damage is observed when bipolar integrated circuits are irradiated at low temperature. This can be partially explained by the Onsager theory of recombination, which predicts a strong temperature dependence for charge yield under low-field conditions. Reduced damage occurs for biased as well as unbiased devices because the weak fringing field in thick bipolar oxides only affects charge yield near the Si/SiO2 interface, a relatively small fraction of the total oxide thickness. Lowering the temperature of bipolar ICs - either continuously, or for time periods when they are exposed to high radiation levels - provides an additional degree of freedom to improve total dose performance of bipolar circuits, particularly in space applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tilton, Susan C.; Markillie, Lye Meng; Hays, Spencer
Our goal here was to identify dose and temporal dependent radiation responses in a complex tissue, reconstituted human skin. Direct sequencing of RNA (RNA-seq) was used to quantify altered transcripts following exposure to 0.1, 2 and 10 Gy of ionizing radiation at 3 and 8 hours. These doses include a low dose in the range of some medical diagnostic procedures (0.1 Gy), a dose typically received during radiotherapy (2.0 Gy) and a lethal dose (10 Gy). These doses could be received after an intentional or accidental radiation exposure and biomarkers are needed to rapidly and accurately triage exposed individuals. Amore » total of 1701 genes were deemed to be significantly affected by high dose radiation exposure with the majority of genes affected at 10 Gy. A group of 29 genes including GDF15, BBC3, PPM1D, FDXR, GADD45A, MDM2, CDKN1A, TP53INP1, CYCSP27, SESN1, SESN2, PCNA, and AEN were similarly altered at both 2 and 10 Gy, but not 0.1 Gy, at multiple time points. A much larger group of up regulated genes, including those involved in inflammatory responses, was significantly altered only after a 10 Gy exposure. At high doses, down regulated genes were associated with cell cycle regulation and exhibited an apparent linear response between 2 and 10 Gy. While only a handful of genes were significantly affected by 0.1 Gy exposure using stringent statistical filters, groups of related genes regulating cell cycle progression and inflammatory responses consistently exhibited opposite trends in their regulation compared to the high dose exposures. Differential regulation of PLK1 signaling at low and high doses was confirmed using qRT-PCR. These results indicate that some alterations in gene expression are qualitatively different at low and high doses of radiation in this model system.« less
The Effect of Intra-articular Corticosteroids on Articular Cartilage
Wernecke, Chloe; Braun, Hillary J.; Dragoo, Jason L.
2015-01-01
Background: Intra-articular (IA) corticosteroid therapy has been used for the treatment of inflammation and pain in the knee since the 1950s. Purpose: To review the current literature on the effects of IA corticosteroids on articular cartilage. Study Design: Systematic review. Methods: A MEDLINE and SCOPUS database search was performed, and studies were selected for basic science and clinical trial research on corticosteroids with direct outcome measures of cartilage health. Preliminary searches yielded 1929 articles, and final analysis includes 40 studies. Results: Methylprednisolone, dexamethasone, hydrocortisone, betamethasone, prednisolone, and triamcinolone were reported to display dose-dependent deleterious effects on cartilage morphology, histology, and viability in both in vitro and in vivo models. The beneficial animal in vivo effects of methylprednisolone, hydrocortisone, and triamcinolone occurred at low doses (usually <2-3 mg/dose or 8-12 mg/cumulative total dose in vivo), at which increased cell growth and recovery from damage was observed; the single human clinical trial indicated a beneficial effect of triamcinolone. However, at higher doses (>3 mg/dose or 18-24 mg/cumulative total dose in vivo), corticosteroids were associated with significant gross cartilage damage and chondrocyte toxicity. Dose and time dependency of corticosteroid chondrotoxicity was supported in the in vitro results, however, without clear dose thresholds. Conclusion: Corticosteroids have a time- and dose-dependent effect on articular cartilage, with beneficial effects occurring at low doses and durations and detrimental effects at high doses and durations. Clinically, beneficial effects are supported for IA administration, but the lowest efficacious dose should be used. PMID:26674652
Menegas, Damianos; Katsioulis, Antonis; Theodoridou, Maria; Kremastinou, Jenny; Hadjichristodoulou, Christos
2017-01-01
ABSTRACT Vaccination coverage studies are important in determining a population's vaccination status and strategically adjusting national immunization programs. This study assessed full and timely vaccination coverage of preschool children aged 2–3 y attending nurseries-kindergartens (N-K) nationwide at the socioeconomic crisis onset. Geographically stratified cluster sampling was implemented considering prefectures as strata and N-K as clusters. The N-K were selected by simple random sampling from the sampling frame while their number was proportional to the stratum size. In total, 185 N-K (response rate 93.9%) and 2539 children (response rate 81.5%) participated. Coverage with traditional vaccines for diphtheria-tetanus-pertussis, polio and measles-mumps-rubella was very high (>95%), followed by Haemophilus influenzae type b and varicella vaccines. Despite very high final coverage, delayed vaccination was observed for hepatitis B (48.3% completed by 12 months). Significant delay was observed for the booster dose of pneumococcal conjugate vaccines (PCV) and meningococcal C conjugate vaccines (MCC). Of the total population studied, 82.3% received 3 PCV doses by 12 months, while 62.3% received the fourth dose by 24 months and 76.2% by 30 months. However, 89.6% received at least one MCC dose over 12 months. Timely vaccinated for hepatitis A with 2 doses by 24 months were 6.1%. Coverage was significantly low for Rotavirus (<20%) and influenza (23.1% one dose). High vaccination coverage is maintained for most vaccines at the beginning of the crisis in Greece. Coverage and timeliness show an increasing trend compared to previous studies. Sustained efforts are needed to support the preventive medicine system as socioeconomic instability continues. PMID:27669156
MacVittie, Thomas J; Farese, Ann M; Jackson, William
2015-11-01
Well characterized animal models that mimic the human response to potentially lethal doses of radiation are required to assess the efficacy of medical countermeasures under the criteria of the U.S. Food and Drug Administration "animal rule." Development of a model requires the determination of the radiation dose response relationship and time course of mortality and morbidity across the hematopoietic acute radiation syndrome. The nonhuman primate, rhesus macaque, is a relevant animal model that may be used to determine the efficacy of medical countermeasures to mitigate major signs of morbidity and mortality at selected lethal doses of total body irradiation. A systematic review of relevant studies that determined the dose response relationship for the hematopoietic acute radiation syndrome in the rhesus macaque relative to radiation quality, dose rate, and exposure uniformity has never been performed. The selection of data cohorts was made from the following sources: Ovid Medline (1957-present), PubMed (1954-present), AGRICOLA (1976-present), Web of Science (1954-present), and U.S. HHS REPORT (2002 to present). The following terms were used: Rhesus, total body-irradiation, total body x irradiation, TBI, irradiation, gamma radiation, hematopoiesis, LD50/60, Macaca mulatta, whole-body irradiation, nonhuman primate, NHP, monkey, primates, hematopoietic radiation syndrome, mortality, and nuclear radiation. The reference lists of all studies, published and unpublished, were reviewed for additional studies. The total number of hits across all search sites was 3,001. There were a number of referenced, unpublished, non-peer reviewed government reports that were unavailable for review. Fifteen studies, 11 primary (n = 863) and four secondary (n = 153) studies [n = 1,016 total nonhuman primates (NHP), rhesus Macaca mulatta] were evaluated to provide an informative and consistent review. The dose response relationships (DRRs) were determined for uniform or non-uniform total body irradiation (TBI) with 250 kVp or 2 MeV x radiation, Co gamma radiation and reactor- and nuclear weapon-derived mixed gamma: neutron-radiation, delivered at various dose rates from a total body, bilateral, rotational, or unilateral exposure aspect. The DRRs established by a probit analysis vs. linear dose relationship were characterized by two main parameters or dependent variables: a slope and LD50/30. Respective LD50/30 values for studies that used 250 kVp x radiation (five primary studies combined, n = 338), 2 MeV x radiation, Co gamma radiation, and steady-state reactor-derived mixed gamma:neutron radiation for total body uniform exposures were 521 rad [498, 542], 671 rad [632, 715], 644 rad [613, 678], and 385 rad [357, 413]. The respective slopes were steep and ranged from 0.738 to 1.316. The DRR, LD50/30 values and slopes were also determined for total body, non-uniform, unilateral, pulse-rate exposures of mixed gamma:neutron radiation derived at reactor and nuclear weapon detonations. The LD50/30 values were, respectively, 395 rad [337, 432] and 412 rad [359, 460]. Secondary data sets of limited studies that did not describe a DRR were used to support the mid-to-high lethal dose range for the H-ARS and the threshold dose range for the concurrent acute GI ARS. The available evidence provided a reliable and extensive database that characterized the DRR for the H-ARS in young rhesus macaques exposed to 250 kVp uniform total body x radiation without the benefit of medical management. A less substantial but consistent database demonstrated the DRR for total body exposure of differing radiation quality, dose rate and non-uniform exposure. The DRR for the H-ARS is characterized by steep slopes and relative LD50/30 values that reflect the radiation quality, exposure aspect, and dose rate over a range in time from 1954-2012.
Bousquet, Jean; Barnes, Neil; Gibbs, Michael; Gul, Nadeem; Tomkins, Susan A; Zhou, Xin; Cho, Young-Joo; Park, Hae-Sim; Busse, William; Zhong, Nanshan
2017-04-28
To analyse the efficacy of fluticasone propionate (FP) alone and combined with salmeterol (SAL) in achieving guideline-defined asthma control in Asian patients. A post hoc analysis of the GOAL study in which patients were stratified by prior-medication use into inhaled corticosteroid (ICS)-naïve (Stratum [S] 1), low-dose ICS (S2), and medium-dose ICS (S3), and randomised to receive FP/SAL or FP. Doses were stepped-up every 12 weeks until Totally Controlled asthma or maximum dose was reached (PhI) and then maintained until study end (PhII). The primary endpoint was the proportion of patients achieving Well-Controlled asthma during PhI. Additional endpoints included Total Control and adverse events. Asian and non-Asian patients were analysed separately. In Asian patients in PhI, 74% (n = 87/118) in S1 achieved Well-Controlled asthma with FP/SAL versus 74% (n = 89/121) with FP alone (p = 0.839); corresponding values were 76% (n = 81/107) versus 60% (n = 62/104; p = 0.005) in S2, and 58% (n = 59/102) versus 43% (n = 41/95; p = 0.015) in S3. More patients in all three strata achieved Totally Controlled asthma with FP/SAL versus FP alone. Control was achieved more rapidly and with lower ICS doses with FP/SAL versus FP. A high proportion of patients who achieved control during PhI maintained control during PhII. Similar trends were found in non-Asian patients. No new safety concerns were identified. A greater proportion of Asian patients (S2 and S3, for Well-Controlled; all strata, for Totally Controlled) achieved guideline-defined asthma control with FP/SAL versus FP alone. High proportions of Asian patients in S1 achieved Well-Controlled asthma in both treatment groups.
Gautam, Santosh; Franzini, Luisa; Mikhail, Osama I; Chan, Wenyaw; Turner, Barbara J
2016-03-01
Diabetes mellitus (DM) has well known costly complications but we hypothesized that costs of care for chronic pain treated with opioid analgesic (OA) medications would also be substantial. In a statewide, privately insured cohort of 29,033 adults aged 18 to 64 years with DM and noncancer pain who filled OA prescription(s) from 2008 to 2012, our outcomes were costs for specific health care services and total costs per 6-month intervals after the first filled OA prescription. Average daily OA dose (4 categories) and total dose (quartiles) in morphine-equivalent milligrams were calculated per 6-month interval after the first OA prescription and combined into a novel OA dose measure. Associations of OA measures with costs of care (n = 126,854 6-month intervals) were examined using generalized estimating equations adjusted for clinical conditions, psychotherapeutic drugs, and DM treatment. Incremental costs for each type of health care service and total cost of care increased progressively with average daily and total OA dose versus no OAs. The combined OA measure identified the highest incremental total costs per 6-month interval that were increased by $8,389 for 50- to 99-mg average daily dose plus >900 mg total dose and, by $9,181 and $9,958 respectively, for ≥100 mg average daily dose plus 301- to 900-mg or >900 mg total dose. In this statewide DM cohort, total health care costs per 6-month interval increased progressively with higher average daily OA dose and with total OA dose but the greatest increases of >$8,000 were distinguished by combinations of higher average daily and total OA doses. The higher costs of care for opioid-treated patients appeared for all types of services and likely reflects multiple factors including morbidity from the underlying cause of pain, care and complications related to opioid use, and poorer control of diabetes as found in other studies. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.
Yu, Qing; Su, Yi-xiang; Wang, Wen-wei; Li, An-le; Liu, Cun-li; Wang, Yi-long; Hu, Wan-li
2007-07-01
To study the effects of soybean isoflavone (SI) on born metabolism and morphology in animal model of osteoporosis rats. All 70 female Sprague-Dawley (SD) rats were randomly divided into 7 groups according to the levels of total cholesterol (TC) in serum: hyper-lipoid group, estrogen group, low-dose SI group, middle-dose SI group, high-dose SI group, sham group and normal control groups. Bilateral ovaries were extirpated except sham and normal control groups. Except the rats in normal control group, the other rats were fed with high fat diet. Body weight was weighted ad unam vice per week. The estrogen, different dose of SI or deionized water were fed with intragastric administration for 12 weeks. Vena caudalis serum were collected after being ovariectomized, administered for 4 w, 8 w and killed. Serum alkaline phosphatase (AKP) activity and bone density were measured etc. To interfere of estrogen and SI might recover AKP enzyme activity after its being ovariectomized. There almost sowed no differences between high dose SI intervention and estrogen on bone density and microstructure. Bone loss due to being ovariectomized was relieved after SI intervention. SI might protect cardiocyte myofilament and mitochondrial ultramicrostructure. There was mirror image in estrogen, high dose SI group resembling the normal control group, and there was obvious damage in hyper-lipoids group. There should be effects of high dose SI on bone metabolism and morphology in animal model of osteoporosis rats. Serum AKP enzyme activity and bone density should have significantly recovered, the serum level of calcium and phosphorus were maintained after high dose intervened but no significant effects for low dose of SI.
Kanto, Kousei; Ito, Hiroyuki; Noso, Shinsuke; Babaya, Naru; Hiromine, Yoshihisa; Taketomo, Yasunori; Toma, Junko; Niwano, Fumimaru; Yasutake, Sara; Kawabata, Yumiko; Ikegami, Hiroshi
2017-09-30
Differences in the efficacy and safety of antidiabetic drugs among different ethnic groups are well documented. Metformin is widely used in the treatment of type 2 diabetes in Western countries, but high doses of metformin have been approved only recently for clinical use in Japan. The aim of the present study was to investigate the effects of dosage and dosing frequency on the efficacy and safety of high-dose metformin in Japanese patients. A total of 71 Japanese patients with type 2 diabetes were prospectively studied for the effects of dosage and dosing frequency on the efficacy and safety of metformin during hospitalization. Dose effects were studied in 27 patients treated with 0, 500, 1,000, 1,500 and 2,250 mg/day of metformin. The effect of dosing frequency was compared in 56 patients with 1,500 mg/day of metformin administered either two or three times per day. Significant dose-dependent improvement in daily profiles of blood glucose was observed with metformin dosages up to 1,500 mg/day, with a trend towards further improvement observed at 2,250 mg/day. The efficacy of 1,500 mg of metformin was comparable when the drug was administered either two or three times per day. The most frequently reported side-effects were gastrointestinal symptoms, which were not affected by the dosage or dosing frequency of metformin. These results show that the efficacy of high-dose metformin is dose-dependent in Japanese patients. The efficacy and safety of metformin were similar when the drug was administered either two or three times per day. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Total marrow irradiation using Helical TomoTherapy
NASA Astrophysics Data System (ADS)
Garcia-Fernandez, Lourdes Maria
Clinical dose response data of human tumours are limited or restricted to a radiation dose range determined by the level of toxicity to the normal tissues. This is the case for the most common disseminated plasma cell neoplasm, multiple myeloma, where the maximum dose deliverable to the entire bony skeleton using a standard total body irradiation (TBI) technique is limited to about 12 Gy. This study is part of scientific background of a phase I/II dose escalation clinical trial for multiple myeloma using image-guided intensity modulated radiotherapy (IG-IMRT) to deliver high dose to the entire volume of bone marrow with Helical TomoTherapy (HT). This relatively new technology can deliver highly conformal dose distributions to complex target shapes while reducing the dose to critical normal tissues. In this study tools for comparing and predicting the effectiveness of different approaches to total marrow irradiation (TMI) using HT were provided. The expected dose response for plasma cell neoplasms was computed and a radiobiological evaluation of different treatment cohorts in a dose escalating study was performed. Normal tissue complication probability (NTCP) and tumour control probability (TCP) models were applied to an actual TMI treatment plan for a patient and the implications of using different longitudinal field widths were assessed. The optimum dose was ˜39 Gy for which a predicted tumour control of 95% (+/-3%) was obtained, with a predicted 3% (0, 8%) occurrence of radiation pneumonitis. Tissue sparing was seen by using smaller field widths only in the organs of the head. This suggests it would be beneficial to use the small fields in the head only since using small fields for the whole treatment would lead to long treatment times. In TMI it may be necessary to junction two longitudinally adjacent treatment volumes to form a contiguous planning target volume PTV. For instance, this is the case when a different SUP-INF spatial resolution is required or when the PTV length exceeds the bed travel distance. In this work, the dosimetric challenges associated with junctioning longitudinally adjacent PTVs with HT were analyzed and the feasibility of PTV junctioning was demonstrated. The benefits of spatially dividing or splitting the treatment into a few sub-treatments along the longitudinal direction were also investigated.
Radhard optical patchcords and packaging for satellites using liquid crystal polymers
NASA Astrophysics Data System (ADS)
O'Riorden, S.; Mahapatra, A.
2017-11-01
There are many advantages to employing fiber optics for high capacity satellite communication. However, optical cables can be susceptible to high radiation, temperature extremes and vacuum environment. Any hardware used in these systems must be rugged, durable and immune to the detrimental effects of the aforementioned conditions. Standard COTS optical fiber will darken when exposed to high levels of radiation limiting the effectiveness of the communications system. Of particular concern to satellites in GEO are energetic electrons, bursts of heavy particles due to solar storms which can cause total dose and single event effects (SEE). Conventional fiber optic cables have several issues performing in high radiation environments. Linden has patented and developed a novel cable using an extruded layer of Liquid Crystal Polymer (LCP) applied to commercially available fiber. Total dose effects are minimized by shielding with Liquid Crystal Polymer jacketing. It is a simple, inexpensive way to increase the radiation shielding and mechanical performance of cables in satellites while concomitantly providing hermeticity and thus increased fatigue factor for optical glass. • LCPs exposed to 5000 Mrad dose of gamma rays retain in excess of 90% of their mechanical properties. • LCPs exposed to 1 Mrad radiation dose with energetic protons retain almost 100% of their mechanical strength. Tensile modulus increases with exposure to the radiation. • Weight for weight the proton absorbing power of LCP is 25% better than that of aluminum. We will present experimental data on radhard optical patchcords.
NASA Astrophysics Data System (ADS)
Sebastião, Kátia I.; Almeida-Muradian, Lígia B.; Romanelli, Maria Fernanda; Koseki, Paula Massae; Villavicencio, Anna Lúcia C. H.
2002-03-01
Ionizing radiation is a method for preservation of foods that use the high energy of gamma rays or accelerated electrons, thereby ionizing molecules. The most important precursor of vitamin A is β-carotene, a carotenoid with pro-vitamin A activity. The highly unsaturated chain confers the instability of β-carotene, and some reactions, as isomerisation, can reduce the characteristics of pro-vitamin A. The present study investigated whether increasing doses of 0, 10 and 20 kGy lower the total β-carotene level and if an enhancement of cis-isomers occurred on samples of dehydrated parsley. No differences were observed of either fractions analyzed at doses applied in this study, nor did it contribute to the decrease of vitamin A.
NASA Astrophysics Data System (ADS)
Ainsworth, E. J.; Afzal, S. M. J.; Crouse, D. A.; Hanson, W. R.; Fry, R. J. M.
Early and late murine tissue responses to single or fractionated low doses of heavy charged particles, fission-spectrum neutrons or gamma rays are considered. Damage to the hematopoietic system is emphasized, but results on acute lethality, host response to challenge with transplanted leukemia cells and life-shortening are presented. Low dose rates per fraction were used in some neutron experiments. Split-dose lethality studies (LD 50/30) with fission neutrons indicated greater accumulation of injury during a 9 fraction course (over 17 days) than was the case for γ-radiation. When total doses of 96 or 247 cGy of neutrons or γ rays were given as a single dose or in 9 fractions, a significant sparing effect on femur CFU-S depression was observed for both radiation qualities during the first 11 days, but there was not an earlier return to normal with dose fractionation. During the 9 fraction sequence, a significant sparing effect of low dose rate on CFU-S depression was observed in both neutron and γ-irradiated mice. CFU-S content at the end of the fractionation sequence did not correlate with measured LD 50/30. Sustained depression of femur and spleen CFU-S and a significant thrombocytopenia were observed when a total neutron dose of 240 cGy was given in 72 fractions over 24 weeks at low dose rates. The temporal aspects of CFU-S repopulation were different after a single versus fractionated neutron doses. The sustained reduction in the size of the CFU-S population was accompanied by an increase in the fraction in DNA synthesis. The proliferation characteristics and effects of age were different for radial CFU-S population closely associated with bone, compared with the axial population that can be readily aspirated from the femur. In aged irradiated animals, the CFU-S proliferation/redistribution response to typhoid vaccine showed both an age and radiation effect. After high single doses of neutrons or γ rays, a significant age- and radiation-related deficiency in host defense mechanisms was detected by a shorter mean survival time following challenge with transplantable leukemia cells. Comparison of dose-response curves for life shortening after irradiation with fission-spectrum neutrons or high energy silicon particles indicated high initial slopes for both radiation qualities at low doses, but for higher doses of silicon, the effect per Gy decreased to a value similar to that for γ rays. The two component life-shortening curve for silicon particles has implications for the potential efficacy of radioprotectants. Recent studies on protection against early and late effects by aminothiols, prostaglandins, and other compounds are discussed.
Isanaka, Sheila; Mugusi, Ferdinand; Hawkins, Claudia; Spiegelman, Donna; Okuma, James; Aboud, Said; Guerino, Chalamilla; Fawzi, Wafaie W.
2013-01-01
Context Large randomized trials have previously shown that high-dose micronutrient supplementation can increase CD4 counts and reduce human immunodeficiency virus (HIV) disease progression and mortality among individuals not receiving highly active antiretroviral therapy (HAART); however, the safety and efficacy of such supplementation has not been established in the context of HAART. Objective To test the hypothesis that high-dose multivitamin supplementation vs standard-dose multivitamin supplementation decreases the risk of HIV disease progression or death and improves immunological, virological, and nutritional parameters in patients with HIV initiating HAART. Design, Setting, and Participants A randomized, double-blind, controlled trial of high-dose vs standard-dose multivitamin supplementation for 24 months in 3418 patients with HIV initiating HAART between November 2006 and November 2008 in 7 clinics in Dar es Salaam, Tanzania. Intervention The provision of daily oral supplements of vitamin B complex, vitamin C, and vitamin E at high levels or standard levels of the recommended dietary allowance. Main Outcome Measure The composite of HIV disease progression or death from any cause. Results The study was stopped early in March 2009 because of evidence of increased levels of alanine transaminase (ALT) in patients receiving the high-dose multivitamin supplement. At the time of stopping, 3418 patients were enrolled (median follow-up, 15 months), and there were 2374 HIV disease progression events and 453 observed deaths (2460 total combined events). Compared with standard-dose multivitamin supplementation, high-dose supplementation did not reduce the risk of HIV disease progression or death. The absolute risk of HIV progression or death was 72% in the high-dose group vs 72% in the standard-dose group (risk ratio [RR], 1.00; 95% CI, 0.96–1.04). High-dose supplementation had no effect on CD4 count, plasma viral load, body mass index, or hemoglobin level concentration, but increased the risk of ALT elevations (1239 events per 1215 person-years vs 879 events per 1236 person-years; RR, 1.44; 95% CI, 1.11–1.87) vs standard-dose supplementation. Conclusion In adults receiving HAART, use of high-dose multivitamin supplements compared with standard-dose multivitamin supplements did not result in a decrease in HIV disease progression or death but may have resulted in an increase in ALT levels. Trial Registration clinicaltrials.gov Identifier: NCT00383669 PMID:23073950
Schwarte, Sebastian; Bremer, Michael; Fruehauf, Joerg; Sorge, Yanina; Skubich, Susanne; Hoffmann, Matthias W
2007-09-01
Effects of radiation sources used for total body irradiation (TBI) on Graft-versus-Host Disease (GvHD) induction were examined. In a T cell receptor (TCR) transgenic mouse model, single fraction TBI was performed with different radiation devices ((60)Cobalt; (137)Cesium; 6 MV linear accelerator), dose rates (0.85; 1.5; 2.9; 5 Gy/min) and total doses before allogeneic bone marrow transplantation (BMT). Recipients were observed for 120 days. Different tissues were examined histologically. Acute GvHD was induced by a dose rate of 0.85 Gy/min ((60)Cobalt) and a total dose of 9 Gy and injection of 5 x 10(5) lymph node cells plus 5 x 10(6) bone marrow cells. Similar results were obtained using 6 MV linear accelerator- (linac-) photons with a dose rate of 1.5 Gy/min and 0.85 Gy/min, a total dose of 9.5 Gy and injection of same cell numbers. TBI with (137)Cesium (dose rate: 2.5 Gy/min) did not lead reproducibly to lethal acute GvHD. Experimental TBI in murine models may induce different immunological responses, depending on total energy, total single dose and dose rate. GvHD might also be induced by TBI with low dose rates.
Sugiyama, Hideo; Terada, Hiroshi; Isomura, Kimio; Iijima, Ikuyo; Kobayashi, Jun; Kitamura, Kiyoshi
2009-10-01
The isotope (210)Po was suspected of being involved in the death of a former Russian intelligence agent in 2006 in the UK. Although human exposure to this natural radionuclide in foods is estimated to be high, few studies are available. UNSCEAR Report 2000 does not contain data on (210)Po concentrations of foodstuffs in Japan. We analyzed samples of the everyday Japanese diet cooked with foodstuffs purchased at supermarkets in 7 major domestic cities in 2007-2008. (210)Po was quantified by alpha spectrometry and natural radionuclides such as (40)K by gamma spectrometry. The daily intake and committed effective dose of (210)Po, (40)K, and other natural radionuclides for Japanese adults were calculated. Daily intake was 0.34-1.84 (mean +/- sigma : 0.66 +/- 0.53) and 68.5-94.2 (81.5 +/- 8.5) Bq/d and the committed effective dose was 0.15-0.81 (0.29 +/- 0.24) and 0.16-0.21 (0.18 +/- 0.02) mSv for (210)Po and (40)K, respectively, comprising a high percentage of the total exposure. The total of the mean committed effective dose for the two nuclides (0.47 mSv) was higher than the annual effective dose from ingestion of foods reported by UNSCEAR 2000 (0.29 mSv). The mean committed effective dose of (40)K in the 7 major Japanese cities was comparable to the global average (0.17 mSv). The dietary exposure of Japanese adults can be characterized by a higher (210)Po contribution than in other countries. Of the total daily dietary (210)Po exposure (13 food categories excluding water) for adults in Yokohama, about 70% was from fish/shellfish and 20% from vegetables/mushrooms/seaweeds, reflecting preferences of Japanese to eat a considerable amount of fish/shellfish containing high (210)Po concentrations.
Taghizadeh, Mohsen; Memarzadeh, Mohammad Reza; Abedi, Fatemeh; Sharifi, Nasrin; Karamali, Fatemeh; Fakhrieh Kashan, Zohreh; Asemi, Zatollah
2016-08-01
Limited data are available regarding the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight subjects. The current study aimed to assess the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight. This randomized double-blind placebo-controlled clinical trial was conducted on 72 subjects with overweight, aged 18 - 50 years old. Participants were randomly divided into three groups: Group A received high-dose Cumin cyminum L. and lime capsules (75 mg each, n = 24), group B low-dose Cumin cyminum L. and lime capsules (25 mg each, n = 24) and group C placebos (n = 24) twice daily for eight weeks. After eight weeks of intervention, compared with low-dose C. cyminum L. plus lime and placebo, taking high-dose C. cyminum L. plus lime resulted in significant weight loss (in the high-dose group: -2.1 ± 1.7 vs. in the low-dose group: -1.2 ± 1.5 and in the placebo group: + 0.2 ± 1.3 kg, respectively; P < 0.001) and body mass index (-0.8 ± 0.6 vs. -0.5 ± 0.5 and +0.1 ± 0.5 kg/m 2 , respectively; P < 0.001). In addition, administration of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo, led to a significant reduction in fasting plasma glucose (FPG) (P < 0.001) and a significant rise in quantitative insulin sensitivity check index (QUICKI) (+ 0.02 ± 0.02 vs. + 0.01 ± 0.02 and 0.01 ± 0.01, respectively; P = 0.01). Moreover, a significant decrease in serum triglycerides (-14.1 ± 56.2 vs. +13.9 ± 36.8 and + 10.6 ± 25.1 mg/dL; respectively; P = 0.03), total-cholesterol (-18.4 ± 28.6 vs. +8.6 ± 28.5 and -1.0 ± 24.8 mg/dL; respectively; P = 0.004) and low density lipoproteins- (LDL)-cholesterol levels (-11.8 ± 20.7 vs. +6.5 ± 23.2 and -2.9 ± 20.4 mg/dL, respectively; P = 0.01) was observed following the consumption of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo. Results of the current study indicated that taking high-dose C. cyminum L. plus lime for eight weeks among subjects with overweight had beneficial effects on weight, BMI, FPG, QUICKI, triglycerides, total-cholesterol and LDL-cholesterol levels.
Taghizadeh, Mohsen; Memarzadeh, Mohammad Reza; Abedi, Fatemeh; Sharifi, Nasrin; Karamali, Fatemeh; Fakhrieh Kashan, Zohreh; Asemi, Zatollah
2016-01-01
Background Limited data are available regarding the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight subjects. Objectives The current study aimed to assess the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight. Patients and Methods This randomized double-blind placebo-controlled clinical trial was conducted on 72 subjects with overweight, aged 18 - 50 years old. Participants were randomly divided into three groups: Group A received high-dose Cumin cyminum L. and lime capsules (75 mg each, n = 24), group B low-dose Cumin cyminum L. and lime capsules (25 mg each, n = 24) and group C placebos (n = 24) twice daily for eight weeks. Results After eight weeks of intervention, compared with low-dose C. cyminum L. plus lime and placebo, taking high-dose C. cyminum L. plus lime resulted in significant weight loss (in the high-dose group: -2.1 ± 1.7 vs. in the low-dose group: -1.2 ± 1.5 and in the placebo group: + 0.2 ± 1.3 kg, respectively; P < 0.001) and body mass index (-0.8 ± 0.6 vs. -0.5 ± 0.5 and +0.1 ± 0.5 kg/m2, respectively; P < 0.001). In addition, administration of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo, led to a significant reduction in fasting plasma glucose (FPG) (P < 0.001) and a significant rise in quantitative insulin sensitivity check index (QUICKI) (+ 0.02 ± 0.02 vs. + 0.01 ± 0.02 and 0.01 ± 0.01, respectively; P = 0.01). Moreover, a significant decrease in serum triglycerides (-14.1 ± 56.2 vs. +13.9 ± 36.8 and + 10.6 ± 25.1 mg/dL; respectively; P = 0.03), total-cholesterol (-18.4 ± 28.6 vs. +8.6 ± 28.5 and -1.0 ± 24.8 mg/dL; respectively; P = 0.004) and low density lipoproteins- (LDL)-cholesterol levels (-11.8 ± 20.7 vs. +6.5 ± 23.2 and -2.9 ± 20.4 mg/dL, respectively; P = 0.01) was observed following the consumption of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo. Conclusions Results of the current study indicated that taking high-dose C. cyminum L. plus lime for eight weeks among subjects with overweight had beneficial effects on weight, BMI, FPG, QUICKI, triglycerides, total-cholesterol and LDL-cholesterol levels. PMID:27781121
Serum biomarkers for acute hepatotoxicity of Echis pyramidum snake venom in rats.
Asmari, Abdulrahman K Al; Khan, Haseeb A; Banah, Faisal A; Buraidi, Ahmed A Al; Manthiri, Rajamohammed A
2015-01-01
Echis pyramidum is a venomous viper responsible for most cases of envenomation in Arabian Peninsula. We determined the acute phase (3-6 h) changes in serum markers of liver function including alanine aminotransferase (ALT), alkaline phosphatase (ALP), gamma glutamyl transferase (GGT) and bilirubin in adult male Sprague Dawley rats injected with Echis pyramidum venom (EPV) in the doses of 0.00 (control), 0.25, 0.50 and 1.00 mg/kg bodyweight. We also analyzed markers of oxidative stress including superoxide dismutase (SOD), catalase (CAT), total thiols (T-SH) and thiobarbituric acids reactive substances (TBARS) in liver. The results showed significant and dose- and time-dependent increases in serum ALT, ALP and GGT activities after a single injection of EPV. Serum bilirubin was significantly increased by medium and high doses of EVP after 3 h post-injection and then decreased at 6 h. The low dose of EPV neither affected the activity of SOD nor altered the levels of liver T-SH and TBARS, however, it significantly decreased the activity of CAT at 6 h post-injection of EPV. The medium dose of EPV significantly reduced liver SOD activity after 6 h whereas the high dose significantly reduced the SOD activity at 3 h and 6 h post-dosing. Both medium and high doses of EPV caused significant as well as dose- and time-dependent reductions in liver CAT activities. The high dose significantly reduced T-SH and increased TBARS in rat liver. Further studies are warranted to test the pharmacological potential of early phase antioxidant therapy for neutralizing the toxic effects of EPV.
Radiation exposure for manned Mars surface missions
NASA Technical Reports Server (NTRS)
Simonsen, Lisa C.; Nealy, John E.; Townsend, Lawrence W.; Wilson, John W.
1990-01-01
The Langley cosmic ray transport code and the Langley nucleon transport code (BRYNTRN) are used to quantify the transport and attenuation of galactic cosmic rays (GCR) and solar proton flares through the Martian atmosphere. Surface doses are estimated using both a low density and a high density carbon dioxide model of the atmosphere which, in the vertical direction, provides a total of 16 g/sq cm and 22 g/sq cm of protection, respectively. At the Mars surface during the solar minimum cycle, a blood-forming organ (BFO) dose equivalent of 10.5 to 12 rem/yr due to galactic cosmic ray transport and attenuation is calculated. Estimates of the BFO dose equivalents which would have been incurred from the three large solar flare events of August 1972, November 1960, and February 1956 are also calculated at the surface. Results indicate surface BFO dose equivalents of approximately 2 to 5, 5 to 7, and 8 to 10 rem per event, respectively. Doses are also estimated at altitudes up to 12 km above the Martian surface where the atmosphere will provide less total protection.
Narayan, Sumit; Goel, Sudha
2011-01-01
The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (< 2 mg/L)--high alkalinity water. Other water samples with higher TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.
²¹⁰Po in the diet at Seville (Spain) and its contribution to the dose by ingestion.
Díaz-Francés, I; Mantero, J; Díaz-Ruiz, J; Manjón, G; García-Tenorio, R
2016-02-01
The activity concentrations of (210)Po have been determined in a total of 24 representative diet samples from Seville (south of Spain), inferring from the obtained values the annual intakes of (210)Po by ingestion of the affected population and the corresponding committed effective doses. The annual intakes of (210)Po and, consequently, the corresponding doses of this radionuclide show a high variability in correspondence with the variability in the composition of the analysed samples over time, and their magnitude is comparable with the estimated ones in other regions/countries of the world with similar diet habits (countries where the marine products have a considerable weight in the diets). Committed effective doses by ingestion higher than 0.1 mSv y(-1) have been estimated exclusively for (210)Po, reflecting the importance of this radionuclide and this route of incorporation in the magnitude of the total doses received by the affected population from natural sources. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marcus, R.B. Jr.; Million, R.R.; Daly, J.W.
1978-11-01
Twenty-two patients with Stage I through IV primary vaginal squamous cell carcinomas treated for cure with radiation therapy are reviewed, with particular emphasis on the relationship of dose to complications and local control. All but 2 patients received 4000 to 6000 rad whole pelvis irradiation plus at least one radium application. Local control was 91%, with an absolute 2-year disease-free survival of 82%. The degree of anaplasia was found to influence prognosis, with all local and distant failures resulting from high-grade lesions. The complication rate was modest, with no fistulae or serious bowel complications. An analysis of total dose (externalmore » plus radium) with respect to local failure and complications showed that no major complications occurred at a combined dose below 9000 rad. An analysis of the individual contributions of external irradiation and radium implants showed that all but one very minor complication occurred at a radium dose of 4000 rad or higher. From these data, overall treatment planning and total dose recommendations are made.« less
Koterov, A N; Ushenkova, L N; Biryukov, A P
2016-01-01
On the basis of all possible publications on the theme included in the previously formed base of sources on molecular epidemiology of RET/PTC rearrangements in thyroid papillary carcinoma a pooled analysis ("simple pooling data") on determination of the dose-effect dependences for RET/PTC frequency in radiogenic carcinomas of various irradiated groups was performed. (They are groups subjected to radiotherapeutic exposure, residents near the Chernobyl nuclear power plant (CNPP) and victims of nuclear bombing). The tendency to Pearson linear correlation (r = 0.746; p = 0.148) between the frequency of RET/PTC and the estimated dose on thyroid in the regions affected by the CNPP accident was revealed. But this tendency was recognized to be random owing to abnormally low values of the indicator for the most contaminated Gomel region. The method tentatively called "case-control" showed reliable differences in thyroid dose values for carcinomas with RET/PTC and without those. The versatility of changes was found: the lack of RET/PTC for radiotherapeutic impacts was associated with higher doses, whereas in case of the CNPP accident and for nuclear bombing victims it was the opposite. Probably, in the first case the "cellular cleaning" phenomenon after exposure to very high doses took place. Search of direct Pearson correlations between average/median thyroid doses on groups and RET/PTC frequency in carcinomas of these groups showed a high reliability for the dose-effect dependences- at the continuous dose scale (for RET/PTC in total and RET/PTC1 respectively: r = 0.830; p = 0.002 and r = 0.906; p = 0.0003); while there was no significant correlation received for RET/PTC3. When using the weighting least square regression analysis (proceeding from the number of carcinomas in samples), the specified regularities remained. Attempts to influence the strength of correlation by exception ofthe data of all the samples connected with the accident on the CNPP did not significantly reduce the strength of associations for RET/PTC in total. On the basis of ordinal scale doses (background, "low" (0.1 Gy), "middle" (0.1-1 Gy) and "large" (1-10 Gy) dose) also found was a significant correlation (Spearman) with the dose for the frequency RET/PTC in total (r = 0.736; p = 0.0098), but for certain types of rearrangements the results were reverse to the previous analysis (the effect was significant only for the RET/PTC3: r = 0.731; p = 0.024). The linear dose-response trends of the Cochrane-Armitage-test for the frequency of RET/PTC in total, RET/PTC1 and RET/PTC3 depending on the dose to the thyroid in the ordinal scale were registered (p, respectively: < 0.0001 < 0.0001 and 0.007). Thus; after more than 20 years of the molecular and epidemiological research of RET/PTC in thyroid radiogenic carcinomas the comprehensive evidence of the dose-effect dependence existence indicating a real relationship between the studied parameters and a radiation factor was obtained for the first time.
Su, Alvin W; McIntosh, Amy L; Schueler, Beth A; Milbrandt, Todd A; Winkler, Jennifer A; Stans, Anthony A; Larson, A Noelle
Intraoperative C-arm fluoroscopy and low-dose O-arm are both reasonable means to assist in screw placement for idiopathic scoliosis surgery. Both using pediatric low-dose O-arm settings and minimizing the number of radiographs during C-arm fluoroscopy guidance decrease patient radiation exposure and its deleterious biological effect that may be associated with cancer risk. We hypothesized that the radiation dose for C-arm-guided fluoroscopy is no less than low-dose O-arm scanning for placement of pedicle screws. A multicenter matched-control cohort study of 28 patients in total was conducted. Fourteen patients who underwent O-arm-guided pedicle screw insertion for spinal fusion surgery in 1 institution were matched to another 14 patients who underwent C-arm fluoroscopy guidance in the other institution in terms of the age of surgery, body weight, and number of imaged spine levels. The total effective dose was compared. A low-dose pediatric protocol was used for all O-arm scans with an effective dose of 0.65 mSv per scan. The effective dose of C-arm fluoroscopy was determined using anthropomorphic phantoms that represented the thoracic and lumbar spine in anteroposterior and lateral views, respectively. The clinical outcome and complications of all patients were documented. The mean total effective dose for the O-arm group was approximately 4 times higher than that of the C-arm group (P<0.0001). The effective dose for the C-arm patients had high variability based on fluoroscopy time and did not correlate with the number of imaged spine levels or body weight. The effective dose of 1 low-dose pediatric O-arm scan approximated 85 seconds of the C-arm fluoroscopy time. All patients had satisfactory clinical outcomes without major complications that required returning to the operating room. Radiation exposure required for O-arm scans can be higher than that required for C-arm fluoroscopy, but it depends on fluoroscopy time. Inclusion of more medical centers and surgeons will better account for the variability of C-arm dose due to distinct patient characteristics, surgeon's preference, and individual institution's protocol. Level III-case-control study.
Kaynar, Mehmet; Tekinarslan, Erdem; Keskin, Suat; Buldu, İbrahim; Sönmez, Mehmet Giray; Karatag, Tuna; Istanbulluoglu, Mustafa Okan
2015-01-01
To determine and evaluate the effective radiation exposure during a one year follow-up of urolithiasis patients following the SWL (extracorporeal shock wave lithotripsy) treatment. Total Effective Radiation Exposure (ERE) doses for each of the 129 patients: 44 kidney stone patients, 41 ureter stone patients, and 44 multiple stone location patients were calculated by adding up the radiation doses of each ionizing radiation session including images (IVU, KUB, CT) throughout a one year follow-up period following the SWL. Total mean ERE values for the kidney stone group was calculated as 15, 91 mSv (5.10-27.60), for the ureter group as 13.32 mSv (5.10-24.70), and in the multiple stone location group as 27.02 mSv (9.41-54.85). There was no statistically significant differences between the kidney and ureter groups in terms of the ERE dose values (p = 0.221) (p >0.05). In the comparison of the kidney and ureter stone groups with the multiple stone location group; however, there was a statistically significant difference (p = 0.000) (p <0.05). ERE doses should be a factor to be considered right at the initiation of any diagnostic and/or therapeutic procedure. Especially in the case of multiple stone locations, due to the high exposure to ionized radiation, different imaging modalities with low dose and/or totally without a dose should be employed in the diagnosis, treatment, and follow-up bearing the aim to optimize diagnosis while minimizing the radiation dose as much as possible.
Bucklin, Mason H; Acquisto, Nicole M; Nelson, Catherine
2014-05-01
Previous studies have suggested the used of off-label recombinant factor VII (rFVIIa) increases the risk of thromboembolic events, but the effect of the dose of rFVIIa is not well described in the literature. All adult patients that received off-label rFVIIa from 2005-2012 were included in this single-center, retrospective cohort study. The primary endpoint was the incidence of a thromboembolic event in the low dose (<50 mcg/kg) compared to the high dose (≥50 mcg/kg) cohort. Secondary endpoints compared time to thromboembolic event, incidence of arterial compared to venous events, and mortality. There were 152 patients that received rFVIIa during the study period with 66 in the low dose cohort and 86 in the high dose cohort. Mean total dose of rFVIIa was 30.2 mcg/kg (SD ± 9.5 mcg/kg) in the low dose and 99.8 mcg/kg (SD ± 64.7 mcg/kg) in the high dose cohort (p=0.0001). The overall incidence of thromboembolic events was 12.5%. There were 12 (14%) events in the low dose cohort and seven (10.6%) in the high dose cohort, RR=0.76 (95% CI 0.31-1.82). There were no differences in any of the secondary outcomes. A higher incidence of thromboembolic events in cardiothoracic surgery (20.8%) and penetrating trauma patients (21.4%) was seen compared to the remaining cohort (6.7%). No significant difference in the incidence of thromboembolic events was seen between low dose versus high dose rFVIIa over a seven year period at our institution. However, due to the relatively low overall incidence and a small sample size, type II error may be present. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chavez-Santoscoy, Rocío A.; Lecona-Guzmán, Carlos A.; Bogdanchikova, Nina; Salinas-Ruíz, Josafhat; Gómez-Merino, Fernando Carlos; Pestryakov, Alexey
2017-01-01
Background: Hormesis is considered a dose–response phenomenon characterized by growth stimulation at low doses and inhibition at high doses. The hormetic response by silver nanoparticles (AgNPs) on in vitro multiplication of sugarcane was evaluated using a temporary immersion system. Methods: Sugarcane shoots were used as explants cultured in Murashige and Skoog medium with AgNPs at concentrations of 0, 25, 50, 100, and 200 mg/L. Shoot multiplication rate and length were used to determine hormetic response. Total content of phenolic compounds of sugarcane, mineral nutrition, and reactive oxygen species (ROS) was determined. Results: Results were presented as a dose–response curve. Stimulation phase growth was observed at 50 mg/L AgNPs, whereas inhibition phase was detected at 200 mg/L AgNPs. Mineral nutrient analysis showed changes in macronutrient and micronutrient contents due to the effect of AgNPs. Moreover, AgNPs induced ROS production and increased total phenolic content, with a dose-dependent effect. Conclusion: Results suggested that the production of ROS and mineral nutrition are key mechanisms of AgNP-induced hormesis and that phenolic accumulation was obtained as a response of the plant to stress produced by high doses of AgNPs. Therefore, small doses of AgNPs in the culture medium could be an efficient strategy for commercial micropropagation. PMID:29238274
Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.
Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro
2016-12-01
Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is probably under-dosed for the treatment of implant and biofilm associated infections.
Thermoluminescent response of LiF:Mg, Ti to low energy electrons
NASA Astrophysics Data System (ADS)
Mercado-Uribe, H.; Brandan, M. E.
2000-10-01
The dose response curve of LiF:Mg, Ti (TLD-100) exposed to 20 keV electrons from a scanning electron microscope has been measured. The total TL signal shows linear-supralinear behavior. The preliminary results indicate the onset of supralinearity at doses close to 70 Gy. The supralinear response is due to the increasingly important contribution of the high temperature peaks.
Feasibility of intensity-modulated radiotherapy for esophageal cancer in definite chemoradiotherapy.
Hsieh, He-Yuan; Yeh, Hui-Ling; Hsu, Chung-Ping; Lin, Jin-Ching; Chuang, Cheng-Yen; Lin, Jai-Fu; Chang, Chen-Fa
2016-07-01
Esophageal cancer is a highly lethal malignancy, and its treatment has undergone a major evolution over the past 15 years. The objective of this study was to report our experience on the efficacy of definite chemoradiotherapy with the intensity-modulated radiotherapy (IMRT) technique in treating locally advanced esophageal cancer. From September 2004 to November 2011, 39 patients with biopsy-proven esophageal cancer, clinical stage T1-4N0-3M0 according to the American Joint Committee on Cancer 7(th) edition were enrolled. In these enrolled cases, either the tumor was unresectable or the patients refused surgery. All patients received a total radiation dose of 40-56 Gy in 20-28 fractions using IMRT planning. Five to seven radiation beam angles were designed according to the specific shape of the clinical target volume (CTV) and were delivered by a linear accelerator with photons of 6-10 MV energy. The gross tumor volume, CTV, planning target volume, and the organs at risk were outlined, and the homogeneity index (HI) and the conformity index (CI) were calculated. The treatment-related toxicities were also reviewed. The mean follow-up time was 22.4 months (range, 2.0-91.0 months). The 2- and 3-year overall survival rates were 30% and 28%, respectively. The most common Grade 3/4 toxicity was hematologic toxicity (43.6%). The IMRT plans showed high-dose homogeneity to the target, with a calculated HI of 0.9. The calculated CI of 0.8 also showed high conformity treatment dose to target within an acceptable dose range. For the total lungs, the average mean dose was 1313.7 cGy. The V5 and V20 of the total lungs were 67.8% and 23.4%, respectively. For the heart, the average mean dose was 2319.2 cGy. The V30 and V35 of the heart were 30.2% and 21.5%, respectively. Concurrent chemoradiotherapy using the IMRT technique for treating locally advanced unresectable esophageal cancer is feasible, with better conformity of target volume as well as improved sparing of organs at risk. Copyright © 2016. Published by Elsevier Taiwan LLC.
Kuo, Dar-Chih; Hsu, Shih-Ping; Chien, Chiang-Ting
2009-01-01
Increased reactive oxygen species (ROS) and hyperlipidemia can promote arterial thrombus. We evaluated the potential of a partially hydrolyzed guar gum (PHGG) as dietary fiber on lipid profiles and FeCl3-induced arterial thrombosis in the high fat-diet fed hamsters. Our in vitro results found that PHGG is efficient to scavenge O2-•, H2O2, and HOCl. High fat-diet increased plasma triglyceride, total cholesterol, LDL, VLDL, methylguanidine and dityrosine level and accelerated FeCl3-induced arterial thrombosis formation (from 463 ± 51 to 303 ± 45 sec). Low dose PHGG supplement significantly decreased the total cholesterol, LDL, methylguanidine and dityrosine level and delayed the time for arterial thrombosis formation (528 ± 75 sec). High dose PHGG supplement decreased the level in triglyceride, total cholesterol, LDL and VLDL and further delayed the time for arterial thrombus (671 ± 36 sec). The increased Bax protein and decreased Bcl-2 and HSP-70 protein expression was found in the carotid and femoral arteries of high fat-diet hamsters. Low and high dose of PHGG supplement decreased Bax expression and increased Bcl-2 and HSP-70 protein expression. We found that FeCl3 significantly enhanced intercellular adhesion molecule-1 and 4-hydroxynonenal expression in the endothelial site of damaged artery after 150-sec FeCl3 stimulation. PHGG supplement decreased the endothelial ICAM-1 and 4-hydroxynonenal expression after 150-sec FeCl3 stimulation. Based on these results, we conclude that PHGG supplement can increase antioxidant protein expression and thus decrease oxidative stress induced arterial injury. PMID:19272178
Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M
2017-05-01
To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI vol : 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose 4 level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose 4 in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose 4 in the CT imaging of a THA phantom.
High-dose hook effect in six automated human chorionic gonadotrophin assays.
Al-Mahdili, Huda A; Jones, Graham R D
2010-07-01
The high-dose hook effect is a well-known phenomenon of two-site immunoassays including those for human chorionic gonadotrophin (hCG). We investigated the occurrence of a high-dose hook effect in six routinely available hCG assays using a sample with a total hCG concentration of approximately 3,600,000 IU/L. Dilutions of a sample with high hCG concentration were analysed using six common methods: Advia Centaur, Immulite 2000, Dimension RxL, Unicel DxI 800, Roche E170 and Abbott Architect. The measured concentrations and corresponding assay signals were obtained for each method. Performance was compared with manufacturer claims. Four of the tested platforms demonstrated a clear high-dose hook effect, while the other methods showed no hook effect at the highest level tested. Our results indicate that the hook effect may occur in some hCG assays, although the risk of reporting falsely low results was in most cases at higher concentrations than those indicated in manufacturers' product information. Assay design plays a major role in its occurrence. Laboratories should be aware of the assay limitations in this regard.
Nandy, Maitreyee; Sarkar, P K; Sanami, T; Takada, M; Shibata, T
2016-09-01
Measured neutron energy distribution emitted from a thick stopping target of natural carbon at 0°, 30°, 60° and 90° from nuclear reactions caused by 12 MeV amu -1 incident 12 C 5+ ions were converted to energy differential and total neutron absorbed dose as well as ambient dose equivalent H * (10) using the fluence-to-dose conversion coefficients provided by the ICRP. Theoretical estimates were obtained using the Monte Carlo nuclear reaction model code PACE and a few existing empirical formulations for comparison. Results from the PACE code showed an underestimation of the high-energy part of energy differential dose distributions at forward angles whereas the empirical formulation by Clapier and Zaidins (1983 Nucl. Instrum. Methods 217 489-94) approximated the energy integrated angular distribution of H * (10) satisfactorily. Using the measured data, the neutron doses received by some vital human organs were estimated for anterior-posterior exposure. The estimated energy-averaged quality factors were found to vary for different organs from about 7 to about 13. Emitted neutrons having energies above 20 MeV were found to contribute about 20% of the total dose at 0° while at 90° the contribution was reduced to about 2%.
Keum, NaNa; Lee, Dong Hoon; Greenwood, Darren C; Zhang, Xuehong; Giovannucci, Edward L
2015-04-01
Evidence from randomized controlled trials suggests that calcium may protect against recurrence of colorectal adenomas, which could lead to the subsequent prevention of cancer. Yet the trials used only a large single dose and were of small sizes, and thus, knowledge of the dose-response relationship and influence on high-risk adenomas is limited. To address these issues, we conducted linear and nonlinear dose-response meta-analyses primarily based on prospective observational studies published up to July 2014 identified from PubMed and Embase. Summary relative risks (RRs) and 95% confidence intervals (CIs) were calculated for total and supplemental calcium intake, respectively, using a random-effects model. For total calcium intake, summary RR for each 300 mg/day increase was 0.95 (95% CI = 0.92-0.98; I(2) = 45%; eight studies with 11,005 cases; range of intake = 333-2,229 mg/day). Evidence of nonlinearity was indicated: approximately, compared to 550 mg/day of total calcium intake, the summary RR was 0.92 (95% CI = 0.89-0.94) at 1,000 mg/day and 0.87 (95% CI = 0.84-0.90) at 1,450 mg/day (pnonlinearity < 0.01). Associations were stronger for high-risk adenomas (≥1 cm in diameter, (tubulo)villous histology, dysplasia, or multiplicity): approximately, compared to 550 mg/day of total calcium intake, the summary RR was 0.77 (95% CI = 0.74-0.81) at 1,000 mg/day and reduced to 0.69 (95% CI = 0.66-0.73) at 1,450 mg/da (pnonlinearity < 0.01). For supplemental calcium intake, summary RR of total adenoma risk for each 300 mg/day increase was 0.96 (95% CI = 0.93-0.99; I(2) = 0%; three studies with 4,548 cases; range of supplementation = 0-1,366 mg/day). In conclusion, calcium intake may continue to decrease the risk of adenomas, particularly high-risk adenomas, over a wide range of calcium intake. © 2014 UICC.
Safari, Mohammad Javad; Wong, Jeannie Hsiu Ding; Jong, Wei Loong; Thorpe, Nathan; Cutajar, Dean; Rosenfeld, Anatoly; Ng, Kwan Hoong
2017-03-01
The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures. We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors. DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region. Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures. Copyright © 2017 Associazione Italiana di Fisica Medica. All rights reserved.
Alecu, R; Alecu, M
1999-05-01
Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well as the clinical protocol is described. Measurements have been performed for 50 treatments delivered with a Fletcher Suit Delclos applicator. The calculated and in vivo measured values for the "20% reading," i.e., the dose delivered to the diode by the initial 20% of the total dwell time, agreed to within 15%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niewald, Marcus, E-mail: marcus.niewald@uks.eu; Seegenschmiedt, M. Heinrich; Micke, Oliver
2012-11-15
Purpose: To conduct a randomized trial of radiation therapy for painful heel spur, comparing a standard dose with a very low dose. Methods and Materials: Sixty-six patients were randomized to receive radiation therapy either with a total dose of 6.0 Gy applied in 6 fractions of 1.0 Gy twice weekly (standard dose) or with a total dose of 0.6 Gy applied in 6 fractions of 0.1 Gy twice weekly (low dose). In all patients lateral opposing 4- to 6-MV photon beams were used. The results were measured using a visual analogue scale, the Calcaneodynia score, and the SF12 health survey.more » The fundamental phase of the study ended after 3 months, and the follow-up was continued up to 1 year. Patients with insufficient pain relief after 3 months were offered reirradiation with the standard dosage at any time afterward. Results: Of 66 patients, 4 were excluded because of withdrawal of consent or screening failures. After 3 months the results in the standard arm were highly significantly superior compared with those in the low-dose arm (visual analogue scale, P=.001; Calcaneodynia score, P=.027; SF12, P=.045). The accrual of patients was stopped at this point. Further evaluation after 12 months' follow-up showed the following results: (1) highly significant fewer patients were reirradiated in the standard arm compared with the low-dose arm (P<.001); (2) the results of patients in the low-dose arm who were reirradiated were identical to those in the standard arm not reirradiated (reirradiation as a salvage therapy if the lower dose was ineffective); (3) patients experiencing a favorable result after 3 months showed this even after 12 months, and some results even improved further between 3 and 12 months. Conclusions: This study confirms the superior analgesic effect of radiation therapy with 6-Gy doses on painful heel spur even for a longer time period of at least 1 year.« less
NASA Technical Reports Server (NTRS)
Zimmer, J. Paul; Lewis, Sherry M.; Moyer, Jerry L.
1993-01-01
Gavage, water bottle, and diet incorporation are 3 dosing methods used orally to administer test compounds to rodents. These 3 methods were compared in mice to determine which represented the most quantitative delivery system. For dietary incorporation, a high-moisture bolus form of NIH-31 rodent meal was developed using hydroxypropyl methylcellulose as an autoclave-stable binding agent. A high-moisture bolus were selected to increase the acceptability of the dosed diet and to promote quantitative consumption through reduced wastage. The test compound used was D-xylose, a pentose sugar that may be quantitatively detected, colorimetrically, in urine following oral dosing. Six male and 6 female B6D2FI mice were placed in metabolism cages and dosed with a known quantity of D-xylose by each of the 3 methods. Urine was collected before and after each method of administration and analysed for total D-xylose; the per cent recovery was based upon the amount of D-xylose consumed. Quantitative consumption was apparently greatest for water bottle dosing with an average recovery of 56.0% of the original D-xylose dose. High-moisture bolus incorporation ranked second with 50.0% D-xylose recovery, and gavage was third with 41.0% D-xylose recovery.
Soriano, Virtudes; Malvehy, Josep; Berrocal, Alfonso; Martínez de Prado, Purificación; Quindós, María; Soria, Ainara; Márquez-Rodas, Iván; Palacio, Isabel; Cerezuela, Pablo; López-Vivanco, Guillermo; Alonso, Lorenzo; Samaniego, Elia; Ballesteros, Ana; Puértolas, Teresa; Díaz-Beveridge, Rodrigo; de la Cruz-Merino, Luis; López Castro, Rafael; López López, Rafael; Stevinson, Kendall; del Barrio, Patricia; Tornamira, Maria V.; Guillém, Vicente; Martín-Algarra, Salvador
2016-01-01
Adjuvant interferon-α2b (IFN-α2b) has been studied extensively in clinical trials, but there have been few studies of real-world use. The aim of this study is to describe the IFN-α2b real-world patterns in patients with high-risk melanoma in Spain. This was a retrospective and multicentre chart review study of an unselected cohort of patients with melanoma at high risk for relapse (stage IIB/IIC/III) treated with IFN-α2b. Patterns were assessed in terms of dose and compliance to planned treatment. A survival analysis was carried out for the full population and according to Kirkwood scheme compliance and the presence of ulceration. Of 327 patients treated with IFN-α2b, 318 received a high-dose regimen following the standard Kirkwood scheme; thus, patterns are described for this regimen. A total of 121 (38%) and 88 (28%) patients had at least one dose reduction during the induction and maintenance phases, respectively. Dose delay was required in fewer than 10% of patients. A total of 78, 40 and 38% of the patients completed the induction phase, maintenance phase and completed treatment, respectively. The median progression-free and overall survival for the full population were 3.2 and 10.5 years, respectively. There were no differences in progression-free survival and overall survival according to Kirkwood scheme compliance and the presence of ulceration. The most frequent adverse events were neutropenia (31%) and fatigue (30%). High-dose IFN-α2b is the most frequently used regimen in Spain as an adjuvant systemic treatment for high-risk melanoma. Despite poor compliance, in this retrospective study, IFN-α2b treatment provided a benefit consistent with that described previously. PMID:26958991
Espinosa, Enrique; Soriano, Virtudes; Malvehy, Josep; Berrocal, Alfonso; Martínez de Prado, Purificación; Quindós, María; Soria, Ainara; Márquez-Rodas, Iván; Palacio, Isabel; Cerezuela, Pablo; López-Vivanco, Guillermo; Alonso, Lorenzo; Samaniego, Elia; Ballesteros, Ana; Puértolas, Teresa; Díaz-Beveridge, Rodrigo; de la Cruz-Merino, Luis; López Castro, Rafael; López López, Rafael; Stevinson, Kendall; Del Barrio, Patricia; Tornamira, Maria V; Guillém, Vicente; Martín-Algarra, Salvador
2016-06-01
Adjuvant interferon-α2b (IFN-α2b) has been studied extensively in clinical trials, but there have been few studies of real-world use. The aim of this study is to describe the IFN-α2b real-world patterns in patients with high-risk melanoma in Spain. This was a retrospective and multicentre chart review study of an unselected cohort of patients with melanoma at high risk for relapse (stage IIB/IIC/III) treated with IFN-α2b. Patterns were assessed in terms of dose and compliance to planned treatment. A survival analysis was carried out for the full population and according to Kirkwood scheme compliance and the presence of ulceration. Of 327 patients treated with IFN-α2b, 318 received a high-dose regimen following the standard Kirkwood scheme; thus, patterns are described for this regimen. A total of 121 (38%) and 88 (28%) patients had at least one dose reduction during the induction and maintenance phases, respectively. Dose delay was required in fewer than 10% of patients. A total of 78, 40 and 38% of the patients completed the induction phase, maintenance phase and completed treatment, respectively. The median progression-free and overall survival for the full population were 3.2 and 10.5 years, respectively. There were no differences in progression-free survival and overall survival according to Kirkwood scheme compliance and the presence of ulceration. The most frequent adverse events were neutropenia (31%) and fatigue (30%). High-dose IFN-α2b is the most frequently used regimen in Spain as an adjuvant systemic treatment for high-risk melanoma. Despite poor compliance, in this retrospective study, IFN-α2b treatment provided a benefit consistent with that described previously.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Y; Lacroix, F; Lavallee, M
Purpose: To evaluate the commercially released Collapsed Cone convolution-based(CCC) dose calculation module of the Elekta OncentraBrachy(OcB) treatment planning system(TPS). Methods: An allwater phantom was used to perform TG43 benchmarks with single source and seventeen sources, separately. Furthermore, four real-patient heterogeneous geometries (chestwall, lung, breast and prostate) were used. They were selected based on their clinical representativity of a class of clinical anatomies that pose clear challenges. The plans were used as is(no modification). For each case, TG43 and CCC calculations were performed in the OcB TPS, with TG186-recommended materials properly assigned to ROIs. For comparison, Monte Carlo simulation was runmore » for each case with the same material scheme and grid mesh as TPS calculations. Both modes of CCC (standard and high quality) were tested. Results: For the benchmark case, the CCC dose, when divided by that of TG43, yields hot-n-cold spots in a radial pattern. The pattern of the high mode is denser than that of the standard mode and is representative of angular dicretization. The total deviation ((hot-cold)/TG43) is 18% for standard mode and 11% for high mode. Seventeen dwell positions help to reduce “ray-effect”, with the total deviation to 6% (standard) and 5% (high), respectively. For the four patient cases, CCC produces, as expected, more realistic dose distributions than TG43. A close agreement was observed between CCC and MC for all isodose lines, from 20% and up; the 10% isodose line of CCC appears shifted compared to that of MC. The DVH plots show dose deviations of CCC from MC in small volume, high dose regions (>100% isodose). For patient cases, the difference between standard and high modes is almost undiscernable. Conclusion: OncentraBrachy CCC algorithm marks a significant dosimetry improvement relative to TG43 in real-patient cases. Further researches are recommended regarding the clinical implications of the above observations. Support provided by a CIHR grant and CCC system provided by Elekta-Nucletron.« less
Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, Susan, E-mail: srichardson@radonc.wustl.ed; Palaniswaamy, Geethpriya; Grigsby, Perry W.
2010-09-01
Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction.more » The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm{sup 3} (range, 0.01-1.32 cm{sup 3}). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.« less
Ionizing radiation measurements on LDEF: A0015 Free flyer biostack experiment
NASA Technical Reports Server (NTRS)
Benton, E. V.; Frank, A. L.; Benton, E. R.; Csige, I.; Frigo, L. A.
1995-01-01
This report covers the analysis of passive radiation detectors flown as part of the A0015 Free Flyer Biostack on LDEF (Long Duration Exposure Facility). LET (linear energy transfer) spectra and track density measurements were made with CR-39 and Polycarbonate plastic nuclear track detectors. Measurements of total absorbed dose were carried out using Thermoluminescent Detectors. Thermal and resonance neutron dose equivalents were measured with LiF/CR-39 detectors. High energy neutron and proton dose equivalents were measured with fission foil/CR-39 detectors.
Huang, Hsuan-Ming; Hsiao, Ing-Tsung
2016-01-01
In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate.
Huang, Hsuan-Ming; Hsiao, Ing-Tsung
2016-01-01
In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate. PMID:27073853
Uliana, Gustavo Nadal; Tambara, Elizabeth Milla; Baretta, Giorgio Alfredo Pedroso
2015-01-01
The introduction of propofol (2,6-diisopropylphenol) as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE) diagnostic tests. One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student's t-test was used to compare the mean of age, weight, height (cm), and dose (mg/kg) variables between groups. The χ(2) test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was α<0.05. There was significant statistical difference between the study groups and the control group regarding the parameters of propofol injection pain and total dose of propofol (mg/kg) used. However, there were no statistical differences between the two study groups for these parameters. We conclude that the use of remifentanil at doses of 0.2mg/kg and 0.3mg/kg was effective for reducing both the propofol injection pain and the total dose of propofol used. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
The risk of solar proton events to space missions
NASA Technical Reports Server (NTRS)
Burrell, M. O.
1972-01-01
The total dose in rads-tissue from solar protons was tabulated for weekly time intervals, and the number of weeks which gave a dose above 25 rads behind 10 g/sq cm of aluminum for the active 6 years of the 19th cycle were called dangerous or large event weeks. The number of such event weeks was found to be only 3 weeks for the past 20 years. Even though the chance for smaller events is examined, it was found that for any reasonable, high confidence level (95%), the smaller events could be ignored. Consequently, the total particle flux for the 19th cycle was divided by a factor of 3 and determined a single large event week. Using this spectrum, the tissue dose in rads is calculated at the center of an aluminum spherical shell.
High-Dose Selenium for the Mitigation of Radiation Injury: A Pilot Study in a Rat Model
Sieber, Fritz; Muir, Sarah A.; Cohen, Eric P.; North, Paula E.; Fish, Brian L.; Irving, Amy A.; Mäder, Marylou; Moulder, John E.
2009-01-01
The purpose of this study was to evaluate in an animal model the safety and efficacy of dietary supplementation with high doses of selenium for the mitigation of the type of radiation injury that might be sustained during a nuclear accident or an act of radiological terrorism. Age-matched male rats were exposed to 10 Gy (single dose) of total-body irradiation (TBI) followed by a syngeneic bone marrow transplant, then randomized to standard drinking water or drinking water supplemented with sodium selenite or seleno-L-methionine. At 21 weeks after TBI, most rats on standard drinking water had severe renal failure with a mean blood urea nitrogen (BUN) level of 124 ± 29 mg/dl (geometric mean ± SE) whereas rats on selenium-supplemented drinking water (100 μg/day) had a mean BUN level of 67 ± 12 mg/dl. The mitigating effect of selenium was confirmed by histopathological analyses. None of the animals on high-dose selenium showed signs of selenium toxicity. Our results suggest that dietary supplementation with high-dose selenium may provide a safe, effective and practical way to mitigate radiation injury to kidneys. PMID:19267564
Kromann, Sofie; Kudirkiene, Egle; Li, Lili; Thoefner, Ida; Daldorph, Elisabeth; Christensen, Jens Peter; Meng, Hecheng; Olsen, Rikke Heidemann
2017-01-01
There is an urgent need for novel antibiotics as the current antibiotics are losing their value due to increased resistance among clinically important bacteria. Sertraline, an on-marked anti-depressive drug, has been shown to modify bacterial activity in vitro, including increasing the susceptibility of Escherichia coli to antibiotics. The aim of the present study was to investigate if the antimicrobial activity of sertraline could be documented under clinical settings, hereunder if sertraline could potentiate the effect of tetracycline in treatment of an experimentally induced ascending infection in poultry. A total of 40 chickens were divided in four groups of 10 chickens each. All chickens were challenged with 4x103 colony forming units (CFU) of a tetracycline resistant E. coli strain using a surgical infection model, and subsequently treated with either high-dose sertraline, tetracycline, a combination hereof or received no treatment. Seven days post challenge all birds were submitted to necropsy and scored pathologically for lesions. The average lesion scores were significantly higher (P<0.05) in the groups that were treated with high-dose sertraline or high-dose sertraline combined with tetracycline. In conclusion high-dose treatments (four times the maximum therapeutic dose for treating human depression) with sertraline as an adjuvant for treatment of antibiotic resistant E. coli infections exacerbate the pathological outcome of infection in chickens.
Kromann, Sofie; Kudirkiene, Egle; Li, Lili; Thoefner, Ida; Daldorph, Elisabeth; Christensen, Jens Peter; Meng, Hecheng
2017-01-01
There is an urgent need for novel antibiotics as the current antibiotics are losing their value due to increased resistance among clinically important bacteria. Sertraline, an on-marked anti-depressive drug, has been shown to modify bacterial activity in vitro, including increasing the susceptibility of Escherichia coli to antibiotics. The aim of the present study was to investigate if the antimicrobial activity of sertraline could be documented under clinical settings, hereunder if sertraline could potentiate the effect of tetracycline in treatment of an experimentally induced ascending infection in poultry. A total of 40 chickens were divided in four groups of 10 chickens each. All chickens were challenged with 4x103 colony forming units (CFU) of a tetracycline resistant E. coli strain using a surgical infection model, and subsequently treated with either high-dose sertraline, tetracycline, a combination hereof or received no treatment. Seven days post challenge all birds were submitted to necropsy and scored pathologically for lesions. The average lesion scores were significantly higher (P<0.05) in the groups that were treated with high-dose sertraline or high-dose sertraline combined with tetracycline. In conclusion high-dose treatments (four times the maximum therapeutic dose for treating human depression) with sertraline as an adjuvant for treatment of antibiotic resistant E. coli infections exacerbate the pathological outcome of infection in chickens. PMID:29020098
Thai, Wai-ee; Wai, Bryan; Lin, Kaity; Cheng, Teresa; Heist, E. Kevin; Hoffmann, Udo; Singh, Jagmeet; Truong, Quynh A.
2012-01-01
Background Efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual source CT (DSCT) protocol, we aim to determine the radiation dose and image quality (IQ) in patients undergoing pulmonary vein (PV) imaging. Methods and Results In 94 patients (61±9 years, 71% male) who underwent 128-slice DSCT (pitch 3.4), radiation dose and IQ were assessed and compared between 69 patients in sinus rhythm (SR) and 25 in atrial fibrillation (AF). Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high-pitch. In a subset of 18 patients with prior magnetic resonance imaging (MRI) for PV assessment, PV anatomy and scan duration were compared to high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 [1.3, 1.9] mSv, with no difference between SR and AF (1.4 vs 1.5 mSv, p=0.22). No high-pitch CT scans were non-diagnostic or had poor IQ. Radiation dose was reduced with high-pitch (1.6 mSv) compared to standard protocols (19.3 mSv, p<0.0001). This radiation dose reduction was seen with SR (1.5 vs 16.7 mSv, p<0.0001) but was more profound with AF (1.9 vs 27.7 mSv, p=0.039). There was excellent agreement of PV anatomy (kappa 0.84, p<0.0001), and a shorter CT scan duration (6 minutes) compared to MRI (41 minutes, p<0.0001). Conclusions Using a high-pitch DSCT protocol, PV imaging can be performed with minimal radiation dose, short scan acquisition, and excellent IQ in patients with SR or AF. This protocol highlights the success of new cardiac CT technology to minimize radiation exposure, giving clinicians a new low-dose imaging alternative to assess PV anatomy. PMID:22586259
NASA Technical Reports Server (NTRS)
Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.
1989-01-01
The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.
NASA Astrophysics Data System (ADS)
Chang, Jianhui; Feng, Wei; Wang, Yingying; Allen, Antiño R.; Turner, Jennifer; Stewart, Blair; Raber, Jacob; Hauer-Jensen, Martin; Zhou, Daohong; Shao, Lijian
2017-05-01
Long-term space mission exposes astronauts to a radiation environment with potential health hazards. High-energy charged particles (HZE), including 28Si nuclei in space, have deleterious effects on cells due to their characteristics with high linear energy transfer and dense ionization. The influence of 28Si ions contributes more than 10% to the radiation dose equivalent in the space environment. Understanding the biological effects of 28Si irradiation is important to assess the potential health hazards of long-term space missions. The hematopoietic system is highly sensitive to radiation injury and bone marrow (BM) suppression is the primary life-threatening injuries after exposure to a moderate dose of radiation. Therefore, in the present study we investigated the acute effects of low doses of 28Si irradiation on the hematopoietic system in a mouse model. Specifically, 6-month-old C57BL/6 J mice were exposed to 0.3, 0.6 and 0.9 Gy 28Si (600 MeV) total body irradiation (TBI). The effects of 28Si TBI on BM hematopoietic stem cells (HSCs) and hematopoietic progenitor cells (HPCs) were examined four weeks after the exposure. The results showed that exposure to 28Si TBI dramatically reduced the frequencies and numbers of HSCs in irradiated mice, compared to non-irradiated controls, in a radiation dose-dependent manner. In contrast, no significant changes were observed in BM HPCs regardless of radiation doses. Furthermore, irradiated HSCs exhibited a significant impairment in clonogenic ability. These acute effects of 28Si irradiation on HSCs may be attributable to radiation-induced apoptosis of HSCs, because HSCs, but not HPCs, from irradiated mice exhibited a significant increase in apoptosis in a radiation dose-dependent manner. However, exposure to low doses of 28Si did not result in an increased production of reactive oxygen species and DNA damage in HSCs and HPCs. These findings indicate that exposure to 28Si irradiation leads to acute HSC damage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorbe, Bengt; Straumits, Andris; Karlsson, Leif
2005-08-01
Purpose To compare two different fractionation schedules for postoperative vaginal high-dose-rate (HDR) irradiation in endometrial carcinomas. Methods and Materials In a complete geographic series of 290 low-risk endometrial carcinomas, the efficacy and side effects of two different fractionation schedules for postoperative vaginal irradiation were evaluated. The patients were treated during the years 1989-2003. The tumors were in International Federation of Gynecology and Obstetrics Stages IA-IB and Grades 1-2. The HDR MicroSelectron afterloading equipment (iridium-192) was used. Perspex vaginal applicators with diameters of 20-30 mm were used, and the dose was specified at 5 mm from the surface of the applicator.more » Six fractions were given, and the overall treatment time was 8 days. The size of the dose per fraction was randomly set to 2.5 Gy (total dose of 15.0 Gy) or 5.0 Gy (total dose of 30.0 Gy). One hundred forty-four patients were treated with the 2.5-Gy fraction and 146 patients with the 5.0-Gy fraction. Results The overall locoregional recurrence rate of the complete series was 1.4% and the rate of vaginal recurrences 0.7%. There was no difference between the two randomized groups. The vaginal shortening measured by colpometry was not significant (p = 0.159) in the 2.5-Gy group (mean, 0.3 cm) but was highly significant (p < 0.000001) in the 5.0-Gy group (mean 2.1 cm) after 5 years. Mucosal atrophy and bleedings were significantly more frequent in the 5.0-Gy group. Symptoms noted in the 2.5-Gy group were not different from what could be expected in a normal group of postmenopausal women. Conclusion The fractionation schedule recommended for postoperative vaginal irradiation in low-risk endometrial carcinoma is six fractions of 2.5 Gy when the HDR technique is used.« less
Phase II Study of High-Dose Photon/Proton Radiotherapy in the Management of Spine Sarcomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeLaney, Thomas F.; Liebsch, Norbert J.; Pedlow, Francis X.
Purpose: Radiotherapy (XRT) for spine sarcomas is constrained by spinal cord, nerve, and viscera tolerance. Negative surgical margins are uncommon; hence, doses of {>=}66 Gy are recommended. A Phase II clinical trial evaluated high-dose photon/proton XRT for spine sarcomas. Methods and Materials: Eligible patients had nonmetastatic, thoracic, lumbar, and/or sacral spine/paraspinal sarcomas. Treatment included pre- and/or postoperative photon/proton XRT with or without radical resection; patients with osteosarcoma and Ewing's sarcoma received chemotherapy. Shrinking fields delivered 50.4 cobalt Gray equivalent (Gy RBE) to subclinical disease, 70.2 Gy RBE to microscopic disease in the tumor bed, and 77.4 Gy RBE to grossmore » disease at 1.8 Gy RBE qd. Doses were reduced for radiosensitive histologies, concurrent chemoradiation, or when diabetes or autoimmune disease present. Spinal cord dose was limited to 63/54 Gy RBE to surface/center. Intraoperative boost doses of 7.5 to 10 Gy could be given by dural plaque. Results: A total of 50 patients (29 chordoma, 14 chondrosarcoma, 7 other) underwent gross total (n = 25) or subtotal (n = 12) resection or biopsy (n = 13). With 48 month median follow-up, 5-year actuarial local control, recurrence-free survival, and overall survival are: 78%, 63%, and 87% respectively. Two of 36 (5.6%) patients treated for primary versus 7/14 (50%) for recurrent tumor developed local recurrence (p < 0.001). Five patients developed late radiation-associated complications; no myelopathy developed but three sacral neuropathies appeared after 77.12 to 77.4 Gy RBE. Conclusions: Local control with this treatment is high in patients radiated at the time of primary presentation. Spinal cord dose constraints appear to be safe. Sacral nerves receiving 77.12-77.4 Gy RBE are at risk for late toxicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grimes, Joshua, E-mail: grimes.joshua@mayo.edu; Celler, Anna
2014-09-15
Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming themore » same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mutzhas, M.F.; Holzle, E.; Hofmann, C.
1981-01-01
A new apparatus (UVASUN 5000) is presented with high radiation energy between 320 to 460 nm. The radiator is a specially developed source for high uv-A intensity, housing a quartz bulb with a mixture of argon, mercury and metal-halides. The uv-A energy in the range of 320 to 400 nm is about 84% of the total radiation energy. Effects of very high doses of uv-A on human skin were studied. Following single uv-A applications the minimal tanning dose uv-A (MTD) and the immediate pigment darkening (IPD) dose of uv-A were established. Repeated exposure to this uv-A delivering system yields longmore » lasting dark brown skin pigmentation without any clinical or histological signs of sunburn (uv-B) damage, epidermal hyperplasia or thickening of the stratum corneum. Minimal therapeutic results were seen in the phototherapy of vitiligo and inflammatory acne.« less
In vivo urethral dose measurements: a method to verify high dose rate prostate treatments.
Brezovich, I A; Duan, J; Pareek, P N; Fiveash, J; Ezekiel, M
2000-10-01
Radiation doses delivered in high dose rate (HDR) brachytherapy are susceptible to many inaccuracies and errors, including imaging, planning and delivery. Consequently, the dose delivered to the patient may deviate substantially from the treatment plan. We investigated the feasibility of using TLD measurements in the urethra to estimate the discrepancy in treatments for prostate cancer. The dose response of the 1 mm diam, 6 mm long LiF rods that we used for the in vivo measurements was calibrated with the 192Ir HDR source, as well as a 60Co teletherapy unit. A train of 20 rods contained in a sterile plastic tube was inserted into the urethral (Foley) catheter for the duration of a treatment fraction, and the measured doses were compared to the treatment plan. Initial results from a total of seven treatments in four patients show good agreement between theory and experiment. Analysis of any one treatment showed agreement within 11.7% +/- 6.2% for the highest dose encountered in the central prostatic urethra, and within 10.4% +/- 4.4% for the mean dose. Taking the average over all seven treatments shows agreement within 1.7% for the maximum urethral dose, and within 1.5% for the mean urethral dose. Based on these initial findings it seems that planned prostate doses can be accurately reproduced in the clinic.
Space Radiation Effects and Reliability Consideration for the Proposed Jupiter Europa Orbiter
NASA Technical Reports Server (NTRS)
Johnston, Allan
2011-01-01
The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.
Altmann, Vivian; Schumacher-Schuh, Artur F; Rieck, Mariana; Callegari-Jacques, Sidia M; Rieder, Carlos R M; Hutz, Mara H
2016-04-01
Levodopa is first-line treatment of Parkinson's disease motor symptoms but, dose response is highly variable. Therefore, the aim of this study was to determine how much levodopa dose could be explained by biological, pharmacological and genetic factors. A total of 224 Parkinson's disease patients were genotyped for SV2C and SLC6A3 polymorphisms by allelic discrimination assays. Comedication, demographic and clinical data were also assessed. All variables with p < 0.20 were included in a multiple regression analysis for dose prediction. The final model explained 23% of dose variation (F = 11.54; p < 0.000001). Although a good prediction model was obtained, it still needs to be tested in an independent sample to be validated.
Krohn, Thomas; Hänscheid, Heribert; Müller, Berthold; Behrendt, Florian F; Heinzel, Alexander; Mottaghy, Felix M; Verburg, Frederik A
2014-11-01
The determinants of successful (131)I therapy of Graves' disease (GD) are unclear. To relate dosimetry parameters to outcome of therapy to identify significant determinants eu- and/or hypothyroidism after (131)I therapy in patients with GD. A retrospective study in which 206 Patients with GD treated in University Hospital between November 1999 and January 2011. All received (131)I therapy aiming at a total absorbed dose to the thyroid of 250 Gy based on pre-therapeutic dosimetry. Post-therapy dosimetric thyroid measurements were performed twice daily until discharge. From these measurements, thyroid (131)I half-life, the total thyroid absorbed dose, and the maximum dose rate after (131)I administration were calculated. In all, 48.5% of patients were hypothyroid and 28.6% of patients were euthyroid after (131)I therapy. In univariate analysis, nonhyperthyroid and hyperthyroid patients only differed by sex. A lower thyroid mass, a higher activity per gram thyroid tissue, a shorter effective thyroidal (131)I half-life, and a higher maximum dose rate, but not the total thyroid absorbed dose, were significantly associated with hypothyroidism. In multivariate analysis, the maximum dose rate remained the only significant determinant of hypothyroidism (P < .001). Maximum dose rates of 2.2 Gy/h and higher were associated with a 100% hypothyroidism rate. Not the total thyroid absorbed dose, but the maximum dose rate is a determinant of successfully achieving hypothyroidism in Graves' disease. Dosimetric concepts aiming at a specific total thyroid absorbed dose will therefore require reconsideration if our data are confirmed prospectively.
Qin, Yan; Nyheim, Hilde; Haram, Else Marie; Moritz, Joseph M; Hustvedt, Svein Olaf
2017-10-16
Absorption of EPA and DHA from Omega-3-acid ethyl ester (EE) concentrate supplements occurs most efficiently when taken in context of a fatty meal; adequate fat intake is required to release bile salts that emulsify and pancreatic enzymes that digest omega-3-containing lipids in the intestine. Current guidelines recommend reduction in fat intake and therefore there is a need to optimize the absorption of Omega-3 in those consuming low-fat or no-fat meals. To this end, BASF has developed an Absorption Acceleration Technology, a novel self-micro-emulsifying delivery system (SMEDS) formulation of highly concentrated Omega-3-acid EE which enables rapid emulsification and microdroplet formation upon entering the aqueous environment of the gut therefore enhances the absorption. Two separate single dose, crossover studies were conducted to determine the relative bioavailability of omega-3-acid EE concentrate, either as a novel SMEDS formulation (PRF-021) or as control, in healthy fasted male and female adults at two dose levels (Study 1 "low dose": 630 mg EPA + DHA in PRF-021 vs. 840 mg EPA + DHA in control; Study 2 "high dose": 1680 mg EPA + DHA in PRF-021 vs. 3360 mg EPA + DHA in control). Blood samples were collected immediately before supplementation and at defined time intervals for 48 h. Plasma concentration of total EPA and DHA were determined for pharmacokinetic analysis, area under the curve (AUC) and maximum observed concentration (C max ) was determined. Total EPA plus DHA absorption from SMEDS formulation PRF-021 were 6.4 and 11.5 times higher compared to control in low- and high-dose studies respectively, determined as the ratio of baseline corrected, dose normalized AUC 0-24h of PRF-021 over that of control. EPA and DHA individually showed differing levels of enhancement: the AUC 0-24h ratio for EPA was 23.8 and 25.7 in low and high dose studies, respectively, and the AUC 0-24h ratio for DHA was 3.6 and 5.6 in low and high dose studies, respectively. C max was also increased for both EPA and DHA 2.7- to 9.2-fold. PRF-021 is a novel SMEDS formulation of Omega-3-acid EE demonstrating a marked improvement in absorption of a single dose of EPA and DHA EE under fasted conditions. This allows adequate absorption of Omega-3 from the supplement without the requirement of a high-fat meal.
Sakakura, Kenichi; Roth, Austin; Ladich, Elena; Shen, Kai; Coleman, Leslie; Joner, Michael; Virmani, Renu
2015-02-01
The Paradise Ultrasound Renal Denervation System is a next-generation catheter-based device which was used to investigate whether the target ablation area can be controlled by changing ultrasound energy and duration to optimise nerve injury while preventing damage to the arterial wall. Five ultrasound doses were tested in a thermal gel model. Catheter-based ultrasound denervation was performed in 15 swine (29 renal arteries) to evaluate five different doses in vivo, and animals were euthanised at seven days for histopathologic assessment. In the gel model, the peak temperature was highest in the low power-long duration (LP-LD) dose, followed by the mid-low power-mid duration (MLP-MD) dose and the mid-high power-short duration (MHP-SD) dose, and lowest in the mid power-short duration (MP-SD) dose and the high power-ultra short duration (HP-USD) dose. In the animal study, total ablation area was significantly greater in the LP-LD group, followed by the MLP-MD group, and it was least in the HP-USD, MP-SD and MHP-SD groups (p=0.02). Maximum distance was significantly greater in the LP-LD group, followed by the MLP-MD group, the MHP-SD group, and the HP-USD group, and shortest in the MP-SD group (p=0.007). The short spare distance was not different among the five groups (p=0.38). Renal artery damage was minimal, while preserving significant nerve damage in all groups. The Paradise Ultrasound Renal Denervation System is a controllable system where total ablation area and depth of ablation can be optimised by changing ultrasound power and duration while sparing renal arterial tissue damage but allowing sufficient peri-arterial nerve damage.
Palifermin: new drug. Prevention of oral mucositis: inappropriate evaluation.
2007-08-01
(1) Patients treated with high-dose chemotherapy combined with total body irradiation (myeloablative therapy) often develop oral mucositis. Prevention is based mainly on sucking ice during chemotherapy. (2) Palifermin is a growth factor marketed for the prevention of severe oral mucositis in adults with malignant haemopathies who are receiving myeloablative therapy followed by peripheral stem cell autografting. (3) Palifermin has not been compared with sucking ice, despite the efficacy of this simple treatment. (4) In a randomised placebo-controlled double-blind trial involving 212 adult patients treated with high-dose chemotherapy and total body irradiation, palifermin reduced the incidence of severe oral mucositis (63% versus 98%) and its duration (about 3 days versus 9 days). The myeloablative regimen used in this trial is not that commonly used in Europe. The efficacy of palifermin during less aggressive regimens, which cause less severe oral mucositis, is not known. (5) The main adverse events noted in clinical trials were erythema and cutaneous oedema. It is not known whether palifermin increases the long-term risk of cancer. (6) Treatment with palifermin is expensive, 4800.00 euros in France); the optimal dosing schedule is not known and the unit dose chosen by the manufacturer is wastefully large. (7) In practice, it remains to be demonstrated that palifermin is more effective than simply sucking ice.
Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A; Zhang, Zhigang; Schmitt, Adam M; Higginson, Daniel S; Lis, Eric; Zelefsky, Michael J; Mechalakos, James; Bilsky, Mark H
2017-01-01
OBJECTIVE An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. METHODS All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3-6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor's histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. RESULTS A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2-141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7-57 months). The median prescribed dose was 2400 cGy (range 1600-2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). CONCLUSIONS High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes.
Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A.; Zhang, Zhigang; Schmitt, Adam M.; Higginson, Daniel S.; Lis, Eric; Zelefsky, Michael J.; Mechalakos, James; Bilsky, Mark H.
2017-01-01
Objective An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. Methods All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3–6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor’s histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. Results A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2–141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7–57 months). The median prescribed dose was 2400 cGy (range 1600–2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). Conclusions High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes. PMID:28041329
Nootash, Shahab; Sheikhzadeh, Najmeh; Baradaran, Behzad; Oushani, Ali Khani; Maleki Moghadam, Mohammad Reza; Nofouzi, Katayoon; Monfaredan, Amir; Aghebati, Leili; Zare, Fatemeh; Shabanzadeh, Sadigheh
2013-12-01
Present study elucidates the efficacy of green tea (Camellia sinensis) on growth performance, immune and antioxidant systems and cytokine gene expression in rainbow trout tissues. Green tea was supplemented at 20, 100, and 500 mg kg(-1) diet and fed to fish (average weight: 23.5 g) for 35 days. No remarkable changes in growth performance were observed among all test groups. Lower lipid peroxidation product and higher superoxide dismutase activity were noted in fish received the medium dose of green tea. Significant increase in serum bactericidal activity and total protein were recorded in all treatment groups. All doses of green tea up-regulated Interleukin-1β transcription in the spleen, while Interleukin-1β mRNA level decreased significantly in the kidney of low dose of green tea. Interleukin-6 mRNA level was up-regulated in the spleen of high dose of green tea and liver of middle and high doses of green tea. High dose and medium dose of green tea up-regulated the interleukin-8 transcription in the kidney and liver, respectively. Meanwhile, green tea inhibited the production of interleukin-10 in all treatment groups compared with control group. Medium dose of green tea up-regulated tumor necrosis factor-α transcription in all fish tissues, while high dose and low dose of green tea enhanced tumor necrosis factor-α mRNA levels in the kidney and spleen, respectively. Present study suggests that green tea especially at 100 mg kg(-1) feed may effectively enhance the antioxidant system and immune system in rainbow trout. Copyright © 2013 Elsevier Ltd. All rights reserved.
Near-Fatal Gastrointestinal Hemorrhage in a Child with Medulloblastoma on High Dose Dexamethasone.
Yecies, Derek; Tawfik, Daniel; Damman, Jennifer; Thorson, Chad; Hong, David S; Grant, Gerald A; Bensen, Rachel; Damian, Mihaela
2017-07-07
A four-year-old female was admitted to a university-based children's hospital with a newly-diagnosed posterior fossa tumor. She was started on famotidine and high-dose dexamethasone and underwent gross total resection of a medulloblastoma. She was continued on dexamethasone and famotidine. She exhibited postoperative posterior fossa syndrome and was started on enteral feeds via the nasoduodenal tube. She had small gastrointestinal bleeds on postoperative days eight, 11, and 18, and was found to have a well-circumscribed posterior duodenal ulcer. On postoperative day 19, she suffered a massive life-threatening gastrointestinal bleed requiring aggressive resuscitation with blood products. She required an emergent laparotomy due to ongoing blood loss and she was found to have posterior duodenal wall erosion into her gastroduodenal artery. She recovered and subsequently began delayed chemotherapy. This case demonstrates a rare and life-threatening complication of high-dose dexamethasone therapy in the setting of posterior fossa pathology despite stress ulcer prophylaxis. We present a historical perspective with the review of the association between duodenal and intracranial pathology and the usage of high-dose dexamethasone in such cases.
Zeng, Xin; Tang, Xia Jiao; Sheng, Xia; Ni, Wu; Xin, Hai Guang; Chen, Wei Zhong; Jiang, Cai Feng; Lin, Yong; Shi, Jian; Shi, Bin; Chen, Yue Xiang; Yuan, Zong Li; Xie, Wei Fen
2015-11-01
To evaluate the efficacy, safety and tolerability of different doses of rifaximin in Chinese patients with liver cirrhosis. This random prospective study included a screening visit, a 2-week treatment period and a subsequent 4-week observation phase. Patients with liver cirrhosis were randomly assigned to a low-dose rifaximin group, a high-dose rifaximin group and the control group in a ratio of 1:1:1. The low-dose and high-dose groups received 400 mg or 600 mg rifaximin per 12 h for 2 weeks, respectively. All other therapeutic strategies remained unchanged in the three groups as long as possible. In total, 60 patients with liver cirrhosis were screened and 43 of them met the eligibility criteria. After 2-week treatment serum endotoxin levels in the low-dose (1.1 ± 0.8 EU/mL) and high-dose rifaximin groups (1.0 ± 0.8 EU/mL) were significantly lower than that in the control group (2.5 ± 1.8 EU/mL), while no significant difference was found between the two rifaximin-treated groups. The effect of high-dose rifaximin on endotoxemia lasted for at least 4 weeks after drug withdrawal. A significant reduction in the abundance of the Veillonellaceae taxa and an increase in the abundance of Bacteroidaceae were shown after 2 weeks of rifaximin therapy. The incidence of adverse events and severe adverse events was similar among the three groups. Low-dose (800 mg/day) rifaximin could be analogous to high-dose (1200 mg/day) rifaximin to reduce the serum endotoxin level after 2 weeks of treatment. © 2015 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
Clustered DNA damages induced in human hematopoietic cells by low doses of ionizing radiation
NASA Technical Reports Server (NTRS)
Sutherland, Betsy M.; Bennett, Paula V.; Cintron-Torres, Nela; Hada, Megumi; Trunk, John; Monteleone, Denise; Sutherland, John C.; Laval, Jacques; Stanislaus, Marisha; Gewirtz, Alan
2002-01-01
Ionizing radiation induces clusters of DNA damages--oxidized bases, abasic sites and strand breaks--on opposing strands within a few helical turns. Such damages have been postulated to be difficult to repair, as are double strand breaks (one type of cluster). We have shown that low doses of low and high linear energy transfer (LET) radiation induce such damage clusters in human cells. In human cells, DSB are about 30% of the total of complex damages, and the levels of DSBs and oxidized pyrimidine clusters are similar. The dose responses for cluster induction in cells can be described by a linear relationship, implying that even low doses of ionizing radiation can produce clustered damages. Studies are in progress to determine whether clusters can be produced by mechanisms other than ionizing radiation, as well as the levels of various cluster types formed by low and high LET radiation.
Wang, Le; Peng, Pingan; Zhang, Ou; Xu, Xiaohan; Yang, Shiwei; Zhao, Yingxin; Zhou, Yujie
2014-01-01
Background Evidence suggests that high-dose statin pretreatment may reduce the risk of periprocedural myocardial infarction (PMI) and major adverse cardiac events (MACE) for certain patients; however, previous analyses have not considered patients with a history of statin maintenance treatment. In this meta-analysis of randomized controlled trials (RCTs), we reevaluated the efficacy of short-term high-dose statin pretreatment to prevent PMI and MACE in an expanded set of patients undergoing elective percutaneous coronary intervention. Methods We searched the PubMed/Medline database for RCTs that compared high-dose statin pretreatment with no statin or low-dose statin pretreatment as a prevention of PMI and MACE. We evaluated the incidence of PMI and MACE, including death, spontaneous myocardial infarction, and target vessel revascularization at the longest follow-up for each study for subgroups stratified by disease classification and prior low-dose statin treatment. Results Twenty-four RCTs with a total of 5,526 patients were identified. High-dose statin pretreatment was associated with 59% relative reduction in PMI (odds ratio [OR]: 0.41; 95% confidence interval [CI]: 0.34–0.49; P<0.00001) and 39% relative reduction in MACE (OR: 0.61; 95% CI: 0.45–0.83; P = 0.002). The benefit of high-dose statin pretreatment on MACE was significant for statin-naive patients (OR: 0.69; 95% CI: 0.50–0.95; P = 0.02) and prior low dose statin-treated patients (OR: 0.28; 95% CI: 0.12–0.65; P = 0.003); and for patients with acute coronary syndrome (OR: 0.52; 95% CI: 0.34–0.79; P = 0.003), but not for patients with stable angina (OR: 0.71; 95% CI 0.45–1.10; P = 0.12). Long-term effects on survival were less obvious. Conclusions High-dose statin pretreatment can result in a significant reduction in PMI and MACE for patients undergoing elective PCI. The positive effect of high-dose statin pretreatment on PMI and MACE is significant for statin-naïve patients and patients with prior treatment. The positive effect of high-dose statin pretreatment on MACE is significant for patients with acute coronary syndrome. PMID:25473831
He, Ying; Chan, Esther W; Man, Kenneth K C; Lau, Wallis C Y; Leung, Wai K; Ho, Lai M; Wong, Ian C K
2014-09-01
A histamine-2 receptor antagonist (H2RA) is one of the common gastroprotective co-therapies used with non-steroidal anti-inflammatory drugs (NSAIDs) for the prevention or treatment of peptic ulcers (PUs). To date, no study has directly compared the prophylactic effectiveness between high-dose and low-dose H2RA. Our objective was to compare the effectiveness of high-dose versus low-dose H2RAs in the primary prophylaxis of PUs among short-term NSAID users. A retrospective cohort study was conducted using the Clinical Data Analysis and Reporting System (CDARS) in Hong Kong. Patients aged 18 years or above who received a single prescription of oral NSAID with oral H2RA were identified within the study period (1 January 2009-31 December 2012). Patients with a history of or risk factors for PU in the corresponding 2 years prior to the index date (of the first NSAID prescription) were excluded. Log binomial regression analysis was used to calculate the relative risk of PU among NSAID users with high-dose H2RA versus low-dose H2RA exposure. Among the NSAID cohort (n = 102,042), 77,509 (76 %) were on low-dose H2RA and 24,533 (24 %) were on high-dose H2RA. Of the total 69 PU cases identified during the drug exposure period, 64 (0.08 %) received low-dose-H2RA and five (0.02 %) received high-dose H2RA. The overall absolute risk of PUs for NSAID users whilst on H2RA was approximately 1 per 1,479 patients. The adjusted relative risk for NSAID users receiving high-dose H2RA versus low-dose H2RA was 0.32 (95 % confidence interval [CI] 0.13-0.79). Patients aged ≥65 years, receiving a longer duration of treatment, or with concomitant use of antiplatelet agents were found to be at higher risk of PU. High-dose H2RA showed greater effectiveness than low-dose H2RA in the primary prophylaxis of NSAID-associated PUs in short-term new users.
Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars; Skov, Lone; Petersen, Peter Meidahl; Loft, Annika; Specht, Lena
2015-05-01
Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT. Copyright © 2015 Elsevier Inc. All rights reserved.
Tekinarslan, Erdem; Keskin, Suat; Buldu, İbrahim; Sönmez, Mehmet Giray; Karatag, Tuna; Istanbulluoglu, Mustafa Okan
2015-01-01
Introduction To determine and evaluate the effective radiation exposure during a one year follow-up of urolithiasis patients following the SWL (extracorporeal shock wave lithotripsy) treatment. Material and methods Total Effective Radiation Exposure (ERE) doses for each of the 129 patients: 44 kidney stone patients, 41 ureter stone patients, and 44 multiple stone location patients were calculated by adding up the radiation doses of each ionizing radiation session including images (IVU, KUB, CT) throughout a one year follow-up period following the SWL. Results Total mean ERE values for the kidney stone group was calculated as 15, 91 mSv (5.10-27.60), for the ureter group as 13.32 mSv (5.10-24.70), and in the multiple stone location group as 27.02 mSv (9.41-54.85). There was no statistically significant differences between the kidney and ureter groups in terms of the ERE dose values (p = 0.221) (p >0.05). In the comparison of the kidney and ureter stone groups with the multiple stone location group; however, there was a statistically significant difference (p = 0.000) (p <0.05). Conclusions ERE doses should be a factor to be considered right at the initiation of any diagnostic and/or therapeutic procedure. Especially in the case of multiple stone locations, due to the high exposure to ionized radiation, different imaging modalities with low dose and/or totally without a dose should be employed in the diagnosis, treatment, and follow-up bearing the aim to optimize diagnosis while minimizing the radiation dose as much as possible. PMID:26568880
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk; Gniadecki, Robert; Iversen, Lars
2015-05-01
Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gymore » in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.« less
Bloemen-van Gurp, Esther J; Mijnheer, Ben J; Verschueren, Tom A M; Lambin, Philippe
2007-11-15
To predict the three-dimensional dose distribution of our total body irradiation technique, using a commercial treatment planning system (TPS). In vivo dosimetry, using metal oxide field effect transistors (MOSFETs) and thermoluminescence detectors (TLDs), was used to verify the calculated dose distributions. A total body computed tomography scan was performed and loaded into our TPS, and a three-dimensional-dose distribution was generated. In vivo dosimetry was performed at five locations on the patient. Entrance and exit dose values were converted to midline doses using conversion factors, previously determined with phantom measurements. The TPS-predicted dose values were compared with the MOSFET and TLD in vivo dose values. The MOSFET and TLD dose values agreed within 3.0% and the MOSFET and TPS data within 0.5%. The convolution algorithm of the TPS, which is routinely applied in the clinic, overestimated the dose in the lung region. Using a superposition algorithm reduced the calculated lung dose by approximately 3%. The dose inhomogeneity, as predicted by the TPS, can be reduced using a simple intensity-modulated radiotherapy technique. The use of a TPS to calculate the dose distributions in individual patients during total body irradiation is strongly recommended. Using a TPS gives good insight of the over- and underdosage in a patient and the influence of patient positioning on dose homogeneity. MOSFETs are suitable for in vivo dosimetry purposes during total body irradiation, when using appropriate conversion factors. The MOSFET, TLD, and TPS results agreed within acceptable margins.
Kim, Won Young; Jun, Jong Hun; Huh, Jin Won; Hong, Sang Bum; Lim, Chae-Man; Koh, Younsuck
2013-12-01
The accuracy of arterial blood pressure (ABP) monitoring is crucial in treating septic shock patients. Clinically significant differences in central to peripheral ABP could develop into sepsis during vasopressor therapy. The aim of this study was to investigate the difference between radial (peripheral) and femoral (central) ABP in septic shock patients receiving high-dose norepinephrine (NE) therapy. This prospective observational study comparing simultaneous intra-arterial measurements of radial and femoral ABP was performed at a university-affiliated, tertiary referral center between October 2008 and March 2009. Patients with septic shock who needed continuous blood pressure monitoring and high-dose NE therapy 0.1 µg/kg per minute or greater to maintain mean arterial pressure (MAP) of 65 mmHg or greater were included. Statistical analysis was conducted using the Bland-Altman method for comparison of repeated measures. In total, 250 sets of systolic, mean, and diastolic femoral and radial ABP were recorded at baseline and after NE titration. Arterial blood pressure readings from the radial artery were underestimated compared with those from the femoral artery. Overall bias (mean difference between simultaneous measurements) between radial and femoral MAP was +4.9 mmHg; however, during high-dose NE therapy, the bias increased to +6.2 mmHg (95% limits of agreement: -6.0 to +18.3 mmHg). Clinically significant radial-femoral MAP differences (MAP ≥5 mmHg) occurred in up to 62.2% of patients with high-dose NE therapy. Radial artery pressure frequently underestimates central pressure in septic shock patients receiving high-dose NE therapy. Femoral arterial pressure monitoring may be more appropriate when high-dose NE therapy is administered.
Nag, S; Orton, C; Young, D; Erickson, B
1999-04-01
The purpose of this study was to survey the brachytherapy practice for cervical cancer in the United States. The Clinical Research Committee of the American Brachytherapy Society (ABS) performed a retrospective survey of individual physicians of the ABS and American Society of Therapeutic Radiologists and Oncologists regarding the details of the brachytherapy techniques they personally used in the treatment of cervical cancer patients for the year 1995. The replies (some of which may have been an estimate only) were tabulated. The scope of this survey did not allow us to verify the data by chart audits. A total of about 3500 questionnaires were mailed out; 521 responses were received. Of these responders, 206 (40%) did not perform any brachytherapy for carcinoma of the cervix in 1995. Of the other 315 responders reporting a total of 4892 patients treated in 1995, 88% used low dose rate (LDR) while 24% used high dose rate (HDR). There was a wide variation in the doses used. For LDR treatments, the median total external beam radiation therapy (EBRT) dose was 45 and 50 Gy and the LDR dose was 42 and 45 Gy for early and advanced cancers, respectively. For HDR treatments, the median EBRT dose was 48 and 50 Gy and the median HDR dose was 29 and 30 Gy for early and advanced cancers, respectively. The median dose per fraction was 6 Gy for a median of five fractions. Interstitial brachytherapy was used as a component of the treatment in 6% of the patients by 21% of responders. Very few responders treated with pulsed or medium dose rates. This retrospective survey showed the current brachytherapy practice pattern in the treatment of cervical cancer in the United States and can serve as a basis for future prospective national brachytherapy data registry. There was wide variation in the practice pattern, emphasizing the urgent need for consensus on these issues. Copyright 1999 Academic Press.
Proschek, Dirk; Kafchitsas, K.; Rauschmann, M. A.; Kurth, A. A.; Vogl, T. J.
2008-01-01
Interventional procedures are associated with high radiation doses for both patients and surgeons. To reduce the risk from ionizing radiation, it is essential to minimize radiation dose. This prospective study was performed to evaluate the effectiveness in reducing radiation dose during facet joint injection in the lumbar spine and to evaluate the feasibility and possibilities of the new real time image guidance system SabreSource™. A total of 60 patients, treated with a standardized injection therapy of the facet joints L4–L5 or L5–S1, were included in this study. A total of 30 patients were treated by fluoroscopy guidance alone, the following 30 patients were treated using the new SabreSource™ system. Thus a total of 120 injections to the facet joints were performed. Pain, according to the visual analogue scale (VAS), was documented before and 6 h after the intervention. Radiation dose, time of radiation and the number of exposures needed to place the needle were recorded. No significant differences concerning age (mean age 60.5 years, range 51–69), body mass index (mean BMI 26.2, range 22.2–29.9) and preoperative pain (VAS 7.9, range 6–10) were found between the two groups. There was no difference in pain reduction between the two groups (60 vs. 61.5%; P = 0.001) but the radiation dose was significantly smaller with the new SabreSource™ system (reduction of radiation dose 32.7%, P = 0.01; reduction of mean entrance surface dose 32.3%, P = 0.01). The SabreSource™ System significantly reduced the radiation dose received during the injection therapy of the lumbar facet joints. With minimal effort for the setup at the beginning of a session, the system is easy to handle and can be helpful for other injection therapies (e.g. nerve root block therapies). PMID:19082641
von Krempelhuber, Alfred; Vollmar, Jens; Pokorny, Rolf; Rapp, Petra; Wulff, Niels; Petzold, Barbara; Handley, Amanda; Mateo, Lyn; Siersbol, Henriette; Kollaritsch, Herwig; Chaplin, Paul
2009-01-01
IMVAMUNE® is a Modified Vaccinia Ankara-based virus that is being developed as a safer 3rd generation smallpox vaccine. In order to determine the optimal dose for further development, a double-blind, randomized Phase II trial was performed testing three different doses of IMVAMUNE® in 164 healthy volunteers. All three IMVAMUNE® doses displayed a favourable safety profile, with local reactions as the most frequent observation. The 1×108 TCID50 IMVAMUNE® dose induced a total antibody response in 94% of the subjects following the first vaccination and the highest peak seroconversion rates by ELISA (100%) and PRNT (71%). This IMVAMUNE® dose was considered to be optimal for the further clinical development of this highly attenuated poxvirus as a safer smallpox vaccine. PMID:19944151
Total Dose Survivability of Hubble Electronic Components
NASA Technical Reports Server (NTRS)
Xapsos, M. A.; Stauffer, C.; Jordan, T.; Poivey, C.; Haskins, D. N.; Lum, G.; Pergosky, A. M.; Smith, D. C.; LaBel, K. A.
2017-01-01
A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.
New Approach to Total Dose Specification for Spacecraft Electronics
NASA Technical Reports Server (NTRS)
Xapsos, Michael
2017-01-01
Variability of the space radiation environment is investigated with regard to total dose specification for spacecraft electronics. It is shown to have a significant impact. A new approach is developed for total dose requirements that replaces the radiation design margin concept with failure probability during a mission.
Huhtaniska, Sanna; Jääskeläinen, Erika; Heikka, Tuomas; Moilanen, Jani S; Lehtiniemi, Heli; Tohka, Jussi; Manjón, José V; Coupé, Pierrick; Björnholm, Lassi; Koponen, Hannu; Veijola, Juha; Isohanni, Matti; Kiviniemi, Vesa; Murray, Graham K; Miettunen, Jouko
2017-08-30
High doses of antipsychotics have been associated with loss in cortical and total gray matter in schizophrenia. However, previous imaging studies have not taken benzodiazepine use into account, in spite of evidence suggesting adverse effects such as cognitive impairment and increased mortality. In this Northern Finland Birth Cohort 1966 study, 69 controls and 38 individuals with schizophrenia underwent brain MRI at the ages of 34 and 43 years. At baseline, the average illness duration was over 10 years. Brain structures were delineated using an automated volumetry system, volBrain, and medication data on cumulative antipsychotic and benzodiazepine doses were collected using medical records and interviews. We used linear regression with intracranial volume and sex as covariates; illness severity was also taken into account. Though both medication doses associated to volumetric changes in subcortical structures, after adjusting for each other and the average PANSS total score, higher scan-interval antipsychotic dose associated only to volume increase in lateral ventricles and higher benzodiazepine dose associated with volume decrease in the caudate nucleus. To our knowledge, there are no previous studies reporting associations between benzodiazepine dose and brain structural changes. Further studies should focus on how these observations correspond to cognition and functioning. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Lu, Ting; Sheng, Hongguang; Wu, Johnna; Cheng, Yuan; Zhu, Jianming; Chen, Yan
2012-06-01
For thousands of years, cinnamon has been used as a traditional treatment in China. However, there are no studies to date that investigate whether cinnamon supplements are able to aid in the treatment of type 2 diabetes in Chinese subjects. We hypothesized cinnamon should be effective in improving blood glucose control in Chinese patients with type 2 diabetes. To address this hypothesis, we performed a randomized, double-blinded clinical study to analyze the effect of cinnamon extract on glycosylated hemoglobin A(1c) and fasting blood glucose levels in Chinese patients with type 2 diabetes. A total of 66 patients with type 2 diabetes were recruited and randomly divided into 3 groups: placebo and low-dose and high-dose supplementation with cinnamon extract at 120 and 360 mg/d, respectively. Patients in all 3 groups took gliclazide during the entire 3 months of the study. Both hemoglobin A(1c) and fasting blood glucose levels were significantly reduced in patients in the low- and high-dose groups, whereas they were not changed in the placebo group. The blood triglyceride levels were also significantly reduced in the low-dose group. The blood levels of total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, and liver transaminase remained unchanged in the 3 groups. In conclusion, our study indicates that cinnamon supplementation is able to significantly improve blood glucose control in Chinese patients with type 2 diabetes. Copyright © 2012 Elsevier Inc. All rights reserved.
Visual Indicators on Vaccine Boxes as Early Warning Tools to Identify Potential Freeze Damage.
Angoff, Ronald; Wood, Jillian; Chernock, Maria C; Tipping, Diane
2015-07-01
The aim of this study was to determine whether the use of visual freeze indicators on vaccines would assist health care providers in identifying vaccines that may have been exposed to potentially damaging temperatures. Twenty-seven sites in Connecticut involved in the Vaccine for Children Program participated. In addition to standard procedures, visual freeze indicators (FREEZEmarker ® L; Temptime Corporation, Morris Plains, NJ) were affixed to each box of vaccine that required refrigeration but must not be frozen. Temperatures were monitored twice daily. During the 24 weeks, all 27 sites experienced triggered visual freeze indicator events in 40 of the 45 refrigerators. A total of 66 triggered freeze indicator events occurred in all 4 types of refrigerators used. Only 1 of the freeze events was identified by a temperature-monitoring device. Temperatures recorded on vaccine data logs before freeze indicator events were within the 35°F to 46°F (2°C to 8°C) range in all but 1 instance. A total of 46,954 doses of freeze-sensitive vaccine were stored at the time of a visual freeze indicator event. Triggered visual freeze indicators were found on boxes containing 6566 doses (14.0% of total doses). Of all doses stored, 14,323 doses (30.5%) were of highly freeze-sensitive vaccine; 1789 of these doses (12.5%) had triggered indicators on the boxes. Visual freeze indicators are useful in the early identification of freeze events involving vaccines. Consideration should be given to including these devices as a component of the temperature-monitoring system for vaccines.
Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro
2018-05-01
The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, L; Shen, C; Wang, J
Purpose: To reduce cone beam CT (CBCT) imaging dose, we previously proposed a progressive dose control (PDC) scheme to employ temporal correlation between CBCT images at different fractions for image quality enhancement. A temporal non-local means (TNLM) method was developed to enhance quality of a new low-dose CBCT using existing high-quality CBCT. To enhance a voxel value, the TNLM method searches for similar voxels in a window. Due to patient deformation among the two CBCTs, a large searching window was required, reducing image quality and computational efficiency. This abstract proposes a deformation-assisted TNLM (DA-TNLM) method to solve this problem. Methods:more » For a low-dose CBCT to be enhanced using a high-quality CBCT, we first performed deformable image registration between the low-dose CBCT and the high-quality CBCT to approximately establish voxel correspondence between the two. A searching window for a voxel was then set based on the deformation vector field. Specifically, the search window for each voxel was shifted by the deformation vector. A TNLM step was then applied using only voxels within this determined window to correct image intensity at the low-dose CBCT. Results: We have tested the proposed scheme on simulated CIRS phantom data and real patient data. The CITS phantom was scanned on Varian onboard imaging CBCT system with coach shifting and dose reducing for each time. The real patient data was acquired in four fractions with dose reduced from standard CBCT dose to 12.5% of standard dose. It was found that the DA-TNLM method can reduce total dose by over 75% on average in the first four fractions. Conclusion: We have developed a PDC scheme which can enhance the quality of image scanned at low dose using a DA-TNLM method. Tests in phantom and patient studies demonstrated promising results.« less
Creemers-Schild, Dina; Kroon, Frank P; Kuijper, Ed J; de Boer, Mark G J
2016-06-01
The recommended treatment of Pneumocystis jirovecii pneumonia (PCP) is high-dose trimethoprim-sulfamethoxazole (TMP-SMX) in an equivalent of TMP 15-20 mg/kg/day and SMX 75-100 mg/kg/day for 2 or 3 weeks. High rates of adverse events are reported with this dose, which raises the question if lower doses are possible. All adult patients diagnosed with PCP in various immune dysfunctions and treated with TMP-SMX between January 1, 2003 and July 1, 2013 in a tertiary university hospital were included. Per institutional protocol, patients initiated treatment on intermediate-dose TMP-SMX (TMP 10-15 mg/kg/day) and could be stepped down to low-dose TMP-SMX (TMP 4-6 mg/kg/day) during treatment. Clinical variables at presentation, relapse rate and mortality rates were compared between intermediate- and step-down treatment groups by uni- and multivariate analyses. A total of 104 patients were included. Twenty-four patients (23 %) were switched to low-dose TMP-SMX after a median of 4.5 days (IQR 2.8-7.0 days). One relapse (4 %) occurred in the step-down group versus none in the intermediate-dose group. The overall 30-day mortality was 13 %. There was 1 death in the step-down group (4 %) compared to 13 deaths (16 %) in the intermediate-dose group. We observed high cure rates of PCP by treatment with intermediate-dose TMP-SMX. In addition, a step-down strategy to low-dose TMP-SMX during treatment in selected patients appears to be safe and does not compromise the outcome of treatment.
Cataldo, Franco; Iglesias-Groth, Susana; Angelini, Giancarlo; Hafez, Yaser
2013-01-01
A series of non-proteinogenic amino acids, most of them found quite commonly in the meteorites known as carbonaceous chondrites, were subjected to solid state radiolysis in vacuum to a total radiation dose of 3.2 MGy corresponding to 23% of the total dose expected to be taken by organic molecules buried in asteroids and meteorites since the beginning of the solar system 4.6 × 109 years ago. The radiolyzed amino acids were studied by FT-IR spectroscopy, Differential Scanning Calorimetry (DSC) and by polarimety and Optical Rotatory Dispersion (ORD). It is shown that an important fraction of each amino acid is able to “survive” the massive dose of radiation, while the enantiomeric excess is partially preserved. Based on the results obtained, it is concluded that it is unsurprising to find amino acids even in enantiomeric excess in carbonaceous chondrites. PMID:25369815
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sillanpaa, Jussi; Chang Jenghwa; Mageras, Gikas
2006-09-15
We report on the capabilities of a low-dose megavoltage cone-beam computed tomography (MV CBCT) system. The high-efficiency image receptor consists of a photodiode array coupled to a scintillator composed of individual CsI crystals. The CBCT system uses the 6 MV beam from a linear accelerator. A synchronization circuit allows us to limit the exposure to one beam pulse [0.028 monitor units (MU)] per projection image. 150-500 images (4.2-13.9 MU total) are collected during a one-minute scan and reconstructed using a filtered backprojection algorithm. Anthropomorphic and contrast phantoms are imaged and the contrast-to-noise ratio of the reconstruction is studied as amore » function of the number of projections and the error in the projection angles. The detector dose response is linear (R{sup 2} value 0.9989). A 2% electron density difference is discernible using 460 projection images and a total exposure of 13 MU (corresponding to a maximum absorbed dose of about 12 cGy in a patient). We present first patient images acquired with this system. Tumors in lung are clearly visible and skeletal anatomy is observed in sufficient detail to allow reproducible registration with the planning kV CT images. The MV CBCT system is shown to be capable of obtaining good quality three-dimensional reconstructions at relatively low dose and to be clinically usable for improving the accuracy of radiotherapy patient positioning.« less
Abugideiri, Mustafa; Nanda, Ronica H; Butker, Charlotte; Zhang, Chao; Kim, Sungjin; Chiang, Kuang-Yueh; Butker, Elizabeth; Khan, Mohammad K; Haight, Ann E; Chen, Zhengjia; Esiashvili, Natia
2016-02-01
This study evaluated factors associated with increased risk of pulmonary toxicity (PT) from any cause in pediatric patients after myeloablative conditioning, using total body irradiation (TBI), followed by allogeneic hematopoietic stem cell transplantation (HSCT). The records of 129 consecutive pediatric patients (range: 1-21 years of age) who underwent TBI-based myeloablative conditioning for hematologic malignancies at our institution between January 2003 and May 2014 were reviewed. Although total TBI doses ranged from 10.5 to 14 Gy, lung doses were limited to 10 Gy with partial transmission blocks. TBI dose rates ranged from 5.6 cGy/min to 20.9 cGy/min. PT was classified using clinical symptoms, radiographic evidence, and ventilatory defects on pulmonary function tests. Noninfectious (idiopathic) pneumonia syndrome (IPS) was characterized by patients exhibiting PT while demonstrating no signs of infection throughout the follow-up period. PT from any cause developed in 70.5% of patients and was significantly associated with increased transplantation-related mortality (TRM) (P=.03) and decreased overall survival (OS) (P=.02). IPS developed in 23.3% of patients but was not associated with increased TRM (P=.6) or decreased OS (P=.5). Acute graft-versus-host disease (GVHD) significantly affected PT (P=.001) but did not significantly influence the development of IPS (P=.4). Infection was a leading cause of PT (75.8%). TBI dose rate significantly affected development of overall PT (P=.02) and was the sole factor to significantly influence the incidence of IPS (P=.002). TBI total dose, dose per fraction, disease type, transplantation chemotherapy, age of patient, sex, and donor type did not significantly impact overall PT or IPS. A high incidence of PT was noted in this large series of homogeneously treated pediatric patients undergoing TBI for allogeneic HSCT. TBI dose rates affected overall PT and strongly influenced IPS. TBI dose rate is a contributing factor influencing pulmonary toxicity and rates less than 15 cGy/min should be considered to decrease the risk of IPS. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abugideiri, Mustafa, E-mail: Mabugid@emory.edu; Nanda, Ronica H.; Butker, Charlotte
Purpose: This study evaluated factors associated with increased risk of pulmonary toxicity (PT) from any cause in pediatric patients after myeloablative conditioning, using total body irradiation (TBI), followed by allogeneic hematopoietic stem cell transplantation (HSCT). Methods and Materials: The records of 129 consecutive pediatric patients (range: 1-21 years of age) who underwent TBI-based myeloablative conditioning for hematologic malignancies at our institution between January 2003 and May 2014 were reviewed. Although total TBI doses ranged from 10.5 to 14 Gy, lung doses were limited to 10 Gy with partial transmission blocks. TBI dose rates ranged from 5.6 cGy/min to 20.9 cGy/min. PT was classified usingmore » clinical symptoms, radiographic evidence, and ventilatory defects on pulmonary function tests. Noninfectious (idiopathic) pneumonia syndrome (IPS) was characterized by patients exhibiting PT while demonstrating no signs of infection throughout the follow-up period. Results: PT from any cause developed in 70.5% of patients and was significantly associated with increased transplantation-related mortality (TRM) (P=.03) and decreased overall survival (OS) (P=.02). IPS developed in 23.3% of patients but was not associated with increased TRM (P=.6) or decreased OS (P=.5). Acute graft-versus-host disease (GVHD) significantly affected PT (P=.001) but did not significantly influence the development of IPS (P=.4). Infection was a leading cause of PT (75.8%). TBI dose rate significantly affected development of overall PT (P=.02) and was the sole factor to significantly influence the incidence of IPS (P=.002). TBI total dose, dose per fraction, disease type, transplantation chemotherapy, age of patient, sex, and donor type did not significantly impact overall PT or IPS. Conclusions: A high incidence of PT was noted in this large series of homogeneously treated pediatric patients undergoing TBI for allogeneic HSCT. TBI dose rates affected overall PT and strongly influenced IPS. TBI dose rate is a contributing factor influencing pulmonary toxicity and rates less than 15 cGy/min should be considered to decrease the risk of IPS.« less
Eaton, John E.; Silveira, Marina G.; Pardi, Darrell S.; Sinakos, Emmanouil; Kowdley, Kris V.; Luketic, Velimir A.C.; Harrison, M. Edwyn; McCashland, Timothy; Befeler, Alex S.; Harnois, Denise; Jorgensen, Roberta; Petz, Jan; Lindor, Keith D.
2011-01-01
OBJECTIVES Some studies have suggested that ursodeoxycholic acid (UDCA) may have a chemopreventive effect on the development of colorectal neoplasia in patients with ulcerative colitis (UC) and primary sclerosing cholangitis (PSC). We examined the effects of high-dose (28–30 mg/kg/day) UDCA on the development of colorectal neoplasia in patients with UC and PSC. METHODS Patients with UC and PSC enrolled in a prior, multicenter randomized placebo-controlled trial of high-dose UDCA were evaluated for the development of colorectal neoplasia. Patients with UC and PSC who received UDCA were compared with those who received placebo. We reviewed the pathology and colonoscopy reports for the development of low-grade or high-grade dysplasia or colorectal cancer. RESULTS Fifty-six subjects were followed for a total of 235 patient years. Baseline characteristics (including duration of PSC and UC, medications, patient age, family history of colorectal cancer, and smoking status) were similar for both the groups. Patients who received high-dose UDCA had a significantly higher risk of developing colorectal neoplasia (dysplasia and cancer) during the study compared with those who received placebo (hazard ratio: 4.44, 95% confidence interval: 1.30–20.10, P=0.02). CONCLUSIONS Long-term use of high-dose UDCA is associated with an increased risk of colorectal neoplasia in patients with UC and PSC. PMID:21556038
Total dose bias dependency and ELDRS effects in bipolar linear devices
NASA Technical Reports Server (NTRS)
Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.
2002-01-01
Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.
Dolton, Michael J; Perera, Vidya; Pont, Lisa G; McLachlan, Andrew J
2014-01-01
Terbinafine is increasingly used in combination with other antifungal agents to treat resistant or refractory mycoses due to synergistic in vitro antifungal activity; high doses are commonly used, but limited data are available on systemic exposure, and no assessment of pharmacodynamic target attainment has been made. Using a physiologically based pharmacokinetic (PBPK) model for terbinafine, this study aimed to predict total and unbound terbinafine concentrations in plasma with a range of high-dose regimens and also calculate predicted pharmacodynamic parameters for terbinafine. Predicted terbinafine concentrations accumulated significantly during the first 28 days of treatment; the area under the concentration-time curve (AUC)/MIC ratios and AUC for the free, unbound fraction (fAUC)/MIC ratios increased by 54 to 62% on day 7 of treatment and by 80 to 92% on day 28 compared to day 1, depending on the dose regimen. Of the high-dose regimens investigated, 500 mg of terbinafine taken every 12 h provided the highest systemic exposure; on day 7 of treatment, the predicted AUC, maximum concentration (Cmax), and minimum concentration (Cmin) were approximately 4-fold, 1.9-fold, and 4.4-fold higher than with a standard-dose regimen of 250 mg once daily. Close agreement was seen between the concentrations predicted by the PBPK model and the observed concentrations, indicating good predictive performance. This study provides the first report of predicted terbinafine exposure in plasma with a range of high-dose regimens.
Evaluation of Myrtus communis Linn. berries (common myrtle) in experimental ulcer models in rats.
Sumbul, Sabiha; Ahmad, Mohd Aftab; Asif, Mohd; Saud, Ibne; Akhtar, Mohd
2010-11-01
The present study was conducted to investigate the protective effect of the dried berries of Myrtus communis L. in gastric ulcer against ethanol, indomethacin and pyloric ligation induced models in Wistar rats. Two doses of aqueous extracts of M. communis (AE( 1) and AE(2)) at the dose 105 and 175 mg/kg, respectively, and methanolic extracts (ME(1) and ME(2)) at the dose of 93 and 154 mg/kg, respectively, were administered orally to animals prior to the exposure of ulcerogens. The parameters taken to assess anti-ulcer activity were ulcer index, gastric juice volume, gastric pH, total acidity, gastric wall mucus and histopathological studies. Oral administration of AE(1) and AE(2) significantly reduced the ulcer index in all models of ulcers. Low dose of aqueous extract and high dose of methanolic extract of M. communis exhibited more significant effect in comparison to omeprazole (standard drug) in ethanol-induced ulcer model. Both the doses of aqueous and methanolic extracts also reduced the gastric juice volume, total acidity and increased the gastric pH and gastric wall mucus content in all the models of ulcers used in the present study. Histopathological examinations of gastric tissues of rats treated with the aqueous and methanolic extracts in indomethacin-induced ulcer exhibited significant ulcer-protective effect at both the dose levels.
Assessment of radiation doses from residential smoke detectors that contain americium-241
NASA Astrophysics Data System (ADS)
Odonnell, F. R.; Etnier, E. L.; Holton, G. A.; Travis, C. C.
1981-10-01
External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv to 20 nSv for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 micro-Sv (0.0006 to 8 mrem) to total body and from 0.06 to 800 micro-Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft squared.
Wang, W S; Tzeng, C H; Hsieh, R K; Chiou, T J; Liu, J H; Yen, C C; Chen, P M
1998-02-01
A 22-year-old woman had a normal full-term delivery 6 years after a successful allogeneic bone marrow transplantation (BMT) for acute myeloid leukemia (AML). Conditioning therapy consisted of cyclophosphamide (120 mg/kg) and total body irradiation (TBI) to a total of 1575 cGy in seven fractions (225 cGy x 7, at a dose rate of 3.5 cGy/min). Graft-versus-host disease prophylaxis was with methotrexate and cyclosporin A. Grade I acute GVHD developed after BMT but there was no chronic GVHD. She became amenorrhoeic after BMT and serial gonadal testing indicated hypergonadotrophic hypogonadism. She became pregnant and delivered a full-term, healthy baby 6 years after BMT. Successful pregnancy after TBI of more than 1200 cGy is extremely rare. This case, to the best of our knowledge, is the second patient who received a higher dose of TBI (1575 cGy) to have a successful pregnancy. This and previous reports indicate that normal pregnancy is possible after BMT with TBI in excess of 1200 cGy.
Effect of low-dose, short-duration creatine supplementation on anaerobic exercise performance.
Hoffman, Jay R; Stout, Jeffrey R; Falvo, Michael J; Kang, Jie; Ratamess, Nicholas A
2005-05-01
To examine the efficacy of a low-dose, short-duration creatine monohydrate supplement, 40 physically active men were randomly assigned to either a placebo or creatine supplementation group (6 g of creatine monohydrate per day). Testing occurred before and at the end of 6 days of supplementation. During each testing session, subjects performed three 15-second Wingate anaerobic power tests. No significant (p > 0.05) group or time differences were observed in body mass, peak power, mean power, or total work. In addition, no significant (p > 0.05) differences were observed in peak power, mean power, or total work. However, the change in the rate of fatigue of total work was significantly (p < 0.05) lower in the creatine supplementation group than in the placebo group, indicating a reduced fatigue rate in subjects supplementing with creatine compared with the placebo. Although the results of this study demonstrated reduced fatigue rates in patients during high-intensity sprint intervals, further research is necessary in examining the efficacy of low-dose, short-term creatine supplementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Kaichao; Hu, Lin-wen; Newton, Thomas
2017-05-01
The Massachusetts Institute of Technology Reactor (MITR-II) is a research reactor in Cambridge, Massachusetts designed primarily for experiments using neutron beam and in-core irradiation facilities. At 6 MW, it delivers neutron flux and energy spectrum comparable to light water reactor (LWR) power reactors in a compact core using highly enriched uranium (HEU) fuel. In the framework of nonproliferation policy, the international community aims to minimize the use of HEU in civilian facilities. Within this context, research and test reactors have started a program to convert HEU fuel to low enriched uranium (LEU) fuel. A new type of LEU fuel basedmore » on a high density alloy of uranium and molybdenum (U-10Mo) is expected to allow the conversion of U.S. domestic high performance reactors like MITR. The current study focuses on the impacts of MITR Maximum Hypothetical Accident (MHA), which is also the Design Basis Accident (DBA), with LEU fuel. The MHA for the MITR is postulated to be a coolant flow blockage in the fuel element that contains the hottest fuel plate. It is assumed that the entire active portion of five fuel plates melts. The analysis shows that, within a 2-h period and by considering all the possible radiation sources and dose pathways, the overall off-site dose is 302.1 mrem (1 rem ¼ 0.01 Sv) Total Effective Dose Equivalent (TEDE) at 8 m exclusion area boundary (EAB) and a higher dose of 392.8 mrem TEDE is found at 21 m EAB. In all cases the dose remains below the 500 mrem total TEDE limit goal based on NUREG-1537 guidelines.« less
The Effects of ELDRS at Ultra-Low Dose Rates
NASA Technical Reports Server (NTRS)
Chen, Dakai; Forney, James; Carts, Martin; Phan, Anthony; Pease, Ronald; Kruckmeyer, Kirby; Cox, Stephen; LaBel, Kenneth; Burns, Samuel; Albarian, Rafi;
2011-01-01
We present results on the effects on ELDRS at dose rates of 10, 5, 1, and 0.5 mrad(Si)/s for a variety of radiation hardened and commercial devices. We observed low dose rate enhancement below 10 mrad(Si)/s in several different parts. The magnitudes of the dose rate effects vary. The TL750L, a commercial voltage regulator, showed dose rate dependence in the functional failures, with initial failures occurring after 10 krad(Si) for the parts irradiated at 0.5 mrad(Si)/s. The RH1021 showed an increase in low dose rate enhancement by 2x at 5 mrad(Si)/s relative to 8 mrad(Si)/s and high dose rate, and parametric failure after 100 krad(Si). Additionally the ELDRS-free devices, such as the LM158 and LM117, showed evidence of dose rate sensitivity in parametric degradations. Several other parts also displayed dose rate enhancement, with relatively lower degradations up to approx.15 to 20 krad(Si). The magnitudes of the dose rate enhancement will likely increase in significance at higher total dose levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isohashi, Fumiaki, E-mail: isohashi@radonc.med.osaka-u.ac.j; Yoshioka, Yasuo; Koizumi, Masahiko
2010-07-01
Purpose: The purpose of this study was to reconfirm our previous findings that the rectal dose and source strength both affect late rectal bleeding after high-dose-rate intracavitary brachytherapy (HDR-ICBT), by using a rectal dose calculated in accordance with the definitions of the International Commission on Radiation Units and Measurements Report 38 (ICRU{sub RP}) or of dose-volume histogram (DVH) parameters by the Groupe Europeen de Curietherapie of the European Society for Therapeutic Radiology and Oncology. Methods and Materials: Sixty-two patients who underwent HDR-ICBT and were followed up for 1 year or more were studied. The rectal dose for ICBT was calculatedmore » by using the ICRP{sub RP} based on orthogonal radiographs or the DVH parameters based on computed tomography (CT). The total dose was calculated as the biologically equivalent dose expressed in 2-Gy fractions (EQD{sub 2}). The relationship between averaged source strength or the EQD{sub 2} and late rectal bleeding was then analyzed. Results: When patients were divided into four groups according to rectal EQD{sub 2} ({>=} or
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hattori, Naoya; Gopal, Ajay K.; Shields, Andrew T.
Purpose: To investigate radiation doses to the testes delivered by a radiolabeled anti-CD20 antibody and its effects on male sex hormone levels. Materials and methods: Testicular uptake and retention of 131I-tositumomab were measured, and testicular absorbed doses were calculated for 67 male patients (54+/-11 years of age) with non-Hodgkin's lymphoma who had undergone myeloablative radioimmunotherapy (RIT) using 131I-tositumomab. Time-activity curves for the major organs, testes, and whole body were generated from planar imaging studies. In a subset of patients, male sex hormones were measured before and 1 year after the therapy. Results: The absorbed dose to the testes showed considerablemore » variability (range=4.4-70.2 Gy). Pretherapy levels of total testosterone were below the lower limit of the reference range, and post-therapy evaluation demonstrated further reduction [4.6+/-1.8 nmol/l (pre-RIT) vs. 3.8+/-2.9 nmol/l (post-RIT), P<0.05]. Patients receiving higher radiation doses to the testes (>=25 Gy) showed a greater reduction [4.7+/-1.6 nmol/l (pre-RIT) vs. 3.3+/-2.7 nmol/l (post-RIT), P<0.05] compared with patients receiving lower doses (<25 Gy), who showed no significant change in total testosterone levels. Conclusion: The testicular radiation absorbed dose varied highly among individual patients. Finally, patients receiving higher doses to the testes were more likely to show post-RIT suppression of testosterone levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romesser, Paul B.; Qureshi, Muhammad M.; Kovalchuk, Nataliya
2014-07-01
To determine the effect of gross tumor volume of the primary (GTV-P) and nodal (GTV-N) disease on planned radiation dose to the brachial plexus (BP) in head and neck intensity-modulated radiotherapy (IMRT). Overall, 75 patients underwent definitive IMRT to a median total dose of 69.96 Gy in 33 fractions. The right BP and left BP were prospectively contoured as separate organs at risk. The GTV was related to BP dose using the unpaired t-test. Receiver operating characteristics curves were constructed to determine optimized volumetric thresholds of GTV-P and GTV-N corresponding to a maximum BP dose cutoff of > 66 Gy.more » Multivariate analyses were performed to account for factors associated with a higher maximal BP dose. A higher maximum BP dose (> 66 vs ≤ 66 Gy) correlated with a greater mean GTV-P (79.5 vs 30.8 cc; p = 0.001) and ipsilateral GTV-N (60.6 vs 19.8 cc; p = 0.014). When dichotomized by the optimized nodal volume, patients with an ipsilateral GTV-N ≥ 4.9 vs < 4.9 cc had a significant difference in maximum BP dose (64.2 vs 59.4 Gy; p = 0.001). Multivariate analysis confirmed that an ipsilateral GTV-N ≥ 4.9 cc was an independent predictor for the BP to receive a maximal dose of > 66 Gy when adjusted individually for BP volume, GTV-P, the use of a low anterior neck field technique, total planned radiation dose, and tumor category. Although both the primary and the nodal tumor volumes affected the BP maximal dose, the ipsilateral nodal tumor volume (GTV-N ≥ 4.9 cc) was an independent predictor for high maximal BP dose constraints in head and neck IMRT.« less
Brange, Charlotte; Smailagic, Amir; Jansson, Anne-Helene; Middleton, Brian; Miller-Larsson, Anna; Taylor, John D; Silberstein, David S; Lal, Harbans
2009-02-01
Clinical studies show that flexible dosing (maintenance and symptom-driven dose adjustments) of budesonide and formoterol (BUD/FORM) improves control of asthma exacerbations as compared to fixed maintenance dosing protocols (maintenance therapy) even when the latter utilize higher BUD/FORM doses. This suggests that dose-response relationships for certain pathobiologic mechanisms in asthma shift over time. Here, we have conducted animal studies to address this issue. (1) To test in an animal asthma-like model whether it is possible to achieve the same or greater pharmacological control over bronchoconstriction and airway/lung inflammation, and with less total drug used, by flexible BUD/FORM dosing (upward adjustment of doses) in association with allergen challenges. (2) To determine whether the benefit requires adjustment of both drug components. Rats sensitized on days 0 and 7 were challenged intratracheally with ovalbumin on days 14 and 21. On days 13-21, rats were treated intratracheally with fixed maintenance or flexible BUD/FORM combinations. On day 22, rats were challenged with methacholine and lungs were harvested for analysis. A flexible BUD/FORM dosing regimen (using 3.3 times less total drug than the fixed maintenance high dose regimen), delivered the same or greater reductions of excised lung gas volume (a measure of gas trapped in lung by bronchoconstriction) and lung weight (a measure of inflammatory oedema). When either BUD or FORM alone was increased on days of challenge, the benefit of the flexible dose upward adjustment was lost. Flexible dosing of the BUD/FORM combination improves the pharmacological inhibition of allergen-induced bronchoconstriction and an inflammatory oedema in an allergic asthma-like rat model.
Oxytocin regimen for labor augmentation, labor progression, and perinatal outcomes.
Zhang, Jun; Branch, D Ware; Ramirez, Mildred M; Laughon, S Katherine; Reddy, Uma; Hoffman, Mathew; Bailit, Jennifer; Kominiarek, Michelle; Chen, Zhen; Hibbard, Judith U
2011-08-01
To examine the effects and safety of high-dose (compared with low-dose) oxytocin regimen for labor augmentation on perinatal outcomes. Data from the Consortium on Safe Labor were used. A total of 15,054 women from six hospitals were eligible for the analysis. Women were grouped based on their oxytocin starting dose and incremental dosing of 1, 2, and 4 milliunits/min. Duration of labor and a number of maternal and neonatal outcomes were compared among these three groups stratified by parity. Multivariable logistic regression and generalized linear mixed model were used to adjust for potential confounders. Oxytocin regimen did not affect the rate of cesarean delivery or other perinatal outcomes. Compared with 1 milliunit/min, the regimens starting with 2 milliunits/min and 4 milliunits/min reduced the duration of first stage by 0.8 hours (95% confidence interval 0.5-1.1) and 1.3 hours (1.0-1.7), respectively, in nulliparous women. No effect was observed on the second stage of labor. Similar patterns were observed in multiparous women. High-dose regimen was associated with a reduced risk of meconium stain, chorioamnionitis, and newborn fever in multiparous women. High-dose oxytocin regimen (starting dose at 4 milliunits/min and increment of 4 millliunits/min) is associated with a shorter duration of first-stage of labor for all parities without increasing the cesarean delivery rate or adversely affecting perinatal outcomes. II.
The reliability studies of nano-engineered SiGe HBTs using Pelletron accelerator
NASA Astrophysics Data System (ADS)
Prakash, A. P. Gnana; Praveen, K. C.; Pushpa, N.; Cressler, John D.
2015-05-01
The effects of high energy ions on the electrical characteristics of silicon-germanium heterojunction bipolar transistors (SiGe HBTs) were studied in the total dose of ranging from 600 krad to 100 Mrad (Si). The two generations (50 GHz and 200 GHz) of SiGe HBTs were exposed to 50 MeV lithium, 75 MeV boron and 100 MeV oxygen ions. The electrical characteristics of SiGe HBTs were studied before and after irradiation. The SiGe HBTs were exposed to 60Co gamma radiation in the same total dose. The results are systematically compared in order to understand the interaction of ions and ionizing radiation with SiGe HBTs.
Radiation tolerant 1 micron CMOS technology
NASA Astrophysics Data System (ADS)
Crevel, P.; Rodde, K.
1991-03-01
Starting from a standard one micron Complementary Metal Oxide Semiconductor (CMOS) for high density, low power memory applications, the degree of radiation tolerance of the baseline process is evaluated. Implemented process modifications to improve latchup sensitivity under heavy ion irradiation as well as total dose effects without changing layout rules are described. By changing doping profiles in Metal Nitride Oxide Semiconductors (MNOS) and P-channel MOS (PMOS) device regions, it is possible to guarantee data sheet specification of a 64 K low power static RAM for total gamma dose up to 35 krad (Si) (and even higher values for the gate array family) without latch up for Linear Energy Transfer LET up to 115 MeV/(mg/cm squared).
STRV RADMON: An integrated high-energy particle detector
NASA Technical Reports Server (NTRS)
Buehler, Martin; Soli, George; Blaes, Brent; Tardio, Gemma
1993-01-01
The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude. On the STRV (Space Technology Research Vehicle) the RADMON's SRAM will be used to detect trapped protons, solar flares, and cosmic rays and to evaluate our ability to predict space results from ground tests.
Nichols, Blake; Kubis, Sherri; Hewlett, Jennifer; Yehya, Nadir; Srinivasan, Vijay
2017-09-01
The 2012 Surviving Sepsis Campaign pediatric guidelines recommend stress dose hydrocortisone in children experiencing catecholamine-dependent septic shock with suspected or proven absolute adrenal insufficiency. We evaluated whether stress dose hydrocortisone therapy in children with catecholamine dependent septic shock correlated with random serum total cortisol levels and was associated with improved outcomes. Retrospective cohort study. Non-cardiac PICU. Critically ill children (1 mo to 18 yr) admitted between January 1, 2013, and December 31, 2013, with catecholamine dependent septic shock who had random serum total cortisol levels measured prior to potential stress dose hydrocortisone therapy. None. The cohort was dichotomized to random serum total cortisol less than 18 mcg/dL and greater than or equal to 18 mcg/dL. Associations of stress dose hydrocortisone with outcomes: PICU mortality, PICU and hospital length of stay, ventilator-free days, and vasopressor-free days were examined. Seventy children with catecholamine-dependent septic shock and measured random serum total cortisol levels were eligible (16% PICU mortality). Although 43% (30/70) had random serum total cortisol less than 18 μg/dL, 60% (42/70) received stress dose hydrocortisone. Children with random serum total cortisol less than 18 μg/dL had lower severity of illness and lower Vasopressor Inotrope Scores than those with random serum total cortisol greater than or equal to 18 μg/dL (all p < 0.05). Children with stress dose hydrocortisone had higher severity of illness and PICU mortality than those without stress dose hydrocortisone (all p < 0.05). Mean random serum total cortisol levels were similar in children with and without stress dose hydrocortisone (21.1 vs 18.7 μg/dL; p = 0.69). In children with random serum total cortisol less than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU and hospital length of stay and fewer ventilator-free days (all p < 0.05). In children with random serum total cortisol greater than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU mortality and fewer ventilator-free days and vasopressor-free days (all p < 0.05). Stress dose hydrocortisone therapy in children with catecholamine-dependent septic shock correlated more with severity of illness than random serum total cortisol levels and was associated with worse outcomes, irrespective of random serum total cortisol levels.
Radiation Dose Testing on Juno High Voltage Cables
NASA Technical Reports Server (NTRS)
Green, Nelson W.; Kirkham, Harold; Kim, Wousik; McAlpine, Bill
2008-01-01
The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10(exp -6) torr and cooled to -50(deg)C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.
Radiation Dose Testing on Juno High Voltage Cables
NASA Technical Reports Server (NTRS)
Green, Nelson W.; Kirkham, Harold; Kim, Wousik; McAlpine, Bill
2008-01-01
The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.
Effects of aspirin and enoxaparin in a rat model of liver fibrosis.
Li, Chen-Jie; Yang, Zhi-Hui; Shi, Xiao-Liu; Liu, De-Liang
2017-09-21
To examine the effects of aspirin and enoxaparin on liver function, coagulation index and histopathology in a rat model of liver fibrosis. METHODS Forty-five male Sprague-Dawley rats were randomly divided into the control group (n = 5) and model group (n = 40). Thioacetamide (TAA) was used to induce liver fibrosis in the model group. TAA-induced fibrotic rats received TAA continuously (n = 9), TAA + low-dose aspirin (n = 9), TAA + high-dose aspirin (n = 9) or TAA + enoxaparin (n = 9) for 4 wk. All rats were euthanized after 4 wk, and both hematoxylin-eosin and Masson staining were performed to observe pathological changes in liver tissue. Liver fibrosis was assessed according to the METAVIR score. Compared with untreated cirrhotic controls, a significant improvement in fibrosis grade was observed in the low-dose aspirin, high-dose aspirin and enoxaparin treated groups, especially in the high-dose aspirin treated group. Alanine aminotransferase and total bilirubin were higher, albumin was lower and both prothrombin time and international normalized ratio were prolonged in the four treatment groups compared to controls. No significant differences among the four groups were observed. Aspirin and enoxaparin can alleviate liver fibrosis in this rat model.
Chihara, Kazuo; Shimatsu, Akira; Kato, Yuzuru; Kohno, Hitoshi; Tanaka, Toshiaki; Takano, Kazue; Irie, Minoru
2006-12-01
Both Japanese and Caucasian adults with GH deficiency (GHD) have pronounced abdominal obesity, which is associated with increased risk of cardiovascular complications. We investigated the effects of GH treatment in 27 adult Japanese GHD patients, 15 with adult onset (AO) and 12 with childhood onset (CO) GHD. Patients initially received GH titrated to 0.012 mg/kg/day for 24 weeks in a double-blind design and the dose was then individualized for each patient according to IGF-I for a further 24 weeks. Dual-energy x-ray absorptiometry (DXA) data were evaluated for percentages of trunk fat, total body fat and lean body mass. Serum IGF-I and lipid concentrations were determined at a central laboratory. There were 25 patients who completed 48 weeks of treatment, with 7, 6 and 12 patients then receiving GH at 0.003, 0.006 and 0.012 mg/kg/day, respectively. With the reductions in dose when individualized between weeks 24 and 48, mean serum IGF-I level was reduced and excessively high values, observed in AO patients on the fixed GH dose, were no longer seen. The decrease from baseline in trunk fat was similar at week 24 (-3.8 +/- 3.3%, p<0.001) and week 48 (-3.1 +/- 3.7%, p<0.001), and the difference between changes was not significant. Total cholesterol was decreased from baseline by -24 +/- 28 mg/dl (p<0.001) at week 24 and -17 +/- 28 mg/dl (p = 0.007) at week 48. Two patients had elevated HbA1c levels: one continued GH treatment after a dose reduction and the other discontinued due to persistent impaired glucose tolerance. Therefore, excessively high IGF-I levels can be avoided by individualized dosing during long-term GH treatment. Individualized dosing maintains the decrease in abdominal fat in adult Japanese GHD patients and should reduce the cardiovascular risk.
Neutron dosimetry in low-earth orbit using passive detectors
NASA Technical Reports Server (NTRS)
Benton, E. R.; Benton, E. V.; Frank, A. L.
2001-01-01
This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the 6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.
Pautas, Cecile; Merabet, Fatiha; Thomas, Xavier; Raffoux, Emmanuel; Gardin, Claude; Corm, Selim; Bourhis, Jean-Henri; Reman, Oumedaly; Turlure, Pascal; Contentin, Nathalie; de Revel, Thierry; Rousselot, Philippe; Preudhomme, Claude; Bordessoule, Dominique; Fenaux, Pierre; Terré, Christine; Michallet, Mauricette; Dombret, Hervé; Chevret, Sylvie; Castaigne, Sylvie
2010-02-10
PURPOSE In patients with acute myeloid leukemia (AML), induction chemotherapy is based on standard doses of anthracyclines and cytarabine. High doses of cytarabine have been reported as being too toxic for patients older than age 50 years, but few studies have evaluated intensified doses of anthracyclines. PATIENTS AND METHODS In this randomized Acute Leukemia French Association 9801 (ALFA-9801) study, high doses of daunorubicin (DNR; 80 mg/m(2)/d x 3 days) or idarubicin (IDA4; 12 mg/m(2)/d x 4 days) were compared with standard doses of idarubicin (IDA3; 12 mg/m(2)/d x 3 days) for remission induction in patients age 50 to 70 years, with an event-free survival (EFS) end point. After two consolidation courses based on intermediate doses of cytarabine, patients in continuous remission were randomly assigned to receive or not receive maintenance therapy with recombinant interleukin-2 (rIL-2; 5 x 10(6) U/m(2) x 5 days each month) for a total duration of 12 months. A total of 468 patients entered the study (median age, 60 years). Results Overall complete remission rate was 77% with significant differences among the three randomization arms (83%, 78%, and 70% in the IDA3, IDA4, and DNR arms, respectively; P = .04). However, no significant differences were observed in relapse incidence, EFS, or overall survival among the three arms. In the 161 patients randomly assigned for maintenance therapy, no difference in outcome was observed between the rIL-2 and the no further treatment arms. CONCLUSION Neither intensification of anthracycline doses nor maintenance with rIL-2 showed a significant impact on AML course, at least as scheduled in this trial.
Doshi, Reena H; Eckhoff, Philip; Cheng, Alvan; Hoff, Nicole A; Mukadi, Patrick; Shidi, Calixte; Gerber, Sue; Wemakoy, Emile Okitolonda; Muyembe-Tafum, Jean-Jacques; Kominski, Gerald F; Rimoin, Anne W
2017-10-27
One of the goals of the Global Measles and Rubella Strategic Plan is the reduction in global measles mortality, with high measles vaccination coverage as one of its core components. While measles mortality has been reduced more than 79%, the disease remains a major cause of childhood vaccine preventable disease burden globally. Measles immunization requires a two-dose schedule and only countries with strong, stable immunization programs can rely on routine services to deliver the second dose. In the Democratic Republic of Congo (DRC), weak health infrastructure and lack of provision of the second dose of measles vaccine necessitates the use of supplementary immunization activities (SIAs) to administer the second dose. We modeled three vaccination strategies using an age-structured SIR (Susceptible-Infectious-Recovered) model to simulate natural measles dynamics along with the effect of immunization. We compared the cost-effectiveness of two different strategies for the second dose of Measles Containing Vaccine (MCV) to one dose of MCV through routine immunization services over a 15-year time period for a hypothetical birth cohort of 3 million children. Compared to strategy 1 (MCV1 only), strategy 2 (MCV2 by SIA) would prevent a total of 5,808,750 measles cases, 156,836 measles-related deaths and save U.S. $199 million. Compared to strategy 1, strategy 3 (MCV2 by RI) would prevent a total of 13,232,250 measles cases, 166,475 measles-related deaths and save U.S. $408 million. Vaccination recommendations should be tailored to each country, offering a framework where countries can adapt to local epidemiological and economical circumstances in the context of other health priorities. Our results reflect the synergistic effect of two doses of MCV and demonstrate that the most cost-effective approach to measles vaccination in DRC is to incorporate the second dose of MCV in the RI schedule provided that high enough coverage can be achieved. Published by Elsevier Ltd.
Is Parenteral Levothyroxine Therapy Safe in Intractable Hypothyroidism?
Peynirci, Hande; Taskiran, Bengur; Erturk, Erdinc; Sisman, Pınar; Ersoy, Canan
2018-06-01
A 32-year old woman was admitted to the hospital due to intractable hypothyroidism refractory to high dose of oral l-thyroxine therapy. She underwent total thyroidectomy and radioactive iodine therapy due to papillary thyroid cancer. After excluding poor adherence to therapy and malabsorption, levothyroxine absorption test was performed. No response was detected. Transient neurologic symptoms developed during the test. She developed 3 attacks consisting of neurologic symptoms during high dose administration. The patient was considered a case of isolated l-thyroxine malabsorption. She became euthyroid after intramuscular twice weekly l-thyroxine therapy. There are a few case reports regarding isolated l-thyroxine. We report successful long term results of twice weekly administered intramuscular l-thyroxine therapy. We also draw attention to neurologic side effects of high dose l-thyroxine therapy. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.
Nino, M. N.; McCutchan, E. A.; Smith, S. V.; ...
2016-02-01
82Rb is a positron-emitting isotope used in cardiac positron emission tomography (PET) imaging which has been reported to deliver a significantly lower effective radiation dose than analogous imaging isotopes like 201Tl and 99mTc sestamibi. High-quality β-decay data are essential to accurately appraise the total dose received by the patients. A source of 82Sr was produced at the Brookhaven Linac Isotope Producer (BLIP), transported to Argonne National Laboratory, and studied with the Gammasphere facility. Significant revisions have been made to the level scheme of 82Kr including 12 new levels, 50 new γ-ray transitions, and the determination of many new spin assignmentsmore » through angular correlations. Lastly, these new high-quality data allow a precise reappraisal of the β-decay strength function and thus the consequent dose received by patients.« less
SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devic, S; Tomic, N; DeBlois, F
2016-06-15
Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response bymore » using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.« less
Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami
2014-05-01
Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less
Thrall, Donald E.; LaRue, Susan M.; Yu, Daohai; Samulski, Thaddeus; Sanders, Linda; Case, Beth; Rosner, Gary; Azuma, Chieko; Poulson, Jeannie; Pruitt, Amy F.; Stanley, Wilma; Hauck, Marlene L.; Williams, Laurel; Hess, Paul; Dewhirst, Mark W.
2009-01-01
Purpose To test that prospective delivery of higher thermal dose is associated with longer tumor control duration. Experimental Design 122 dogs with a heatable soft tissue sarcoma were randomized to receive a low (2–5 CEM43°CT90) or high (20–50 CEM43°CT90) thermal dose in combination with radiotherapy. Most dogs (90%) received 4–6 hyperthermia treatments over 5 weeks. Results In the primary analysis, median (95% CI) duration of local control in the low dose group was 1.2 (0.7–2.1) years versus 1.9 (1.4–3.2) years in the high dose group (logrank p=0.28). The probability (95% CI) of tumor control at one year in the low vs. high dose groups was 0.57 (0.43–0.70) vs. 0.74 (0.62–0.86), respectively. Using multivariable procedure, thermal dose group (p=0.023), total duration of heating (p=0.008), tumor volume (p=0.041) and tumor grade (p=0.027) were significantly related to duration of local tumor control. When correcting for volume, grade and duration of heating, dogs in the low dose group were 2.3 times as likely to experience local failure. Conclusions Thermal dose is directly related to local control duration in irradiated canine sarcomas. Longer heating being associated with shorter local tumor control was unexpected. However, the effect of thermal dose on tumor control was stronger than for heating duration. The heating duration effect is possibly mediated through deleterious effects on tumor oxygenation. These results are the first to show the value of prospectively controlled thermal dose in achieving local tumor control with thermoradiotherapy, and they establish a paradigm for prescribing thermoradiotherapy and writing a thermal prescription. PMID:16033838
Park, Jung Duck; Chung, Yong Hyun; Kim, Choong Yong; Ha, Chang Soo; Yang, Seoung Oh; Khang, Hyun Soo; Yu, In Kyu; Cheong, Hae Kwan; Lee, Jong Seong; Song, Chang-Woo; Kwon, Il Hoon; Han, Jeong Hee; Sung, Jae Hyuck; Heo, Jeong Doo; Choi, Byung Sun; Im, Ruth; Jeong, Jayoung; Yu, Il Je
2007-09-01
Several pharmacokinetic studies on inhalation exposure to manganese (Mn) have already demonstrated that Mn readily accumulates in the olfactory and brain regions. However, a shortening of the magnetic resonance imaging (MRI) T1 relaxation time or high T1 signal intensity in specific sites of the brain, including the globus pallidus and subcortical frontal white matter, as indicative of tissue manganese accumulation has not yet been clearly established for certain durations of known doses of welding-fume exposure in experimental animals. Accordingly, to investigate the movement of manganese after welding-fume exposure, six cynomolgus monkeys were acclimated and assigned to three dose groups: unexposed, low dose (31 mg/m(3) total suspended particulate [TSP], 0.9 mg/m(3) of Mn), and high dose (62 mg/m(3) TSP, 1.95 mg/m(3) of Mn) of total suspended particulate. The primates were exposed to manual metal arc stainless steel (MMA-SS) welding fumes for 2 h per day in an inhalation chamber system equipped with an automatic fume generator. Magnetic resonance imaging (MRI) studies were conducted before the initiation of exposure and thereafter every month. The tissue Mn concentrations were then measured after a plateau was reached regarding the shortening of the MRI T1 relaxation time. A dose-dependent increase in the Mn concentration was found in the lungs, while noticeable increases in the Mn concentrations were found in certain tissues, such as the liver, kidneys, and testes. Slight increases in the Mn concentrations were found in the caudate, putamen, frontal lobe, and substantia nigra, while a dose-dependent noticeable increase was only found in the globus pallidus. Therefore, the present results indicated that a shortening of the MRI T1 relaxation time corresponded well with the Mn concentration in the globus pallidus after prolonged welding-fume exposure.
J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE.
Gomoll, A; Wanich, T; Bellare, A
2002-11-01
Radiation and chemical cross-linking of medical grade ultrahigh molecular weight polyethylene (UHMWPE) has recently been utilized in an effort to improve wear performance of total joint replacement components. However, reductions in mechanical properties with cross-linking are cause for concern regarding the use of cross-linked UHMWPE for high-stress applications such as in total knee replacement prostheses. In this study, the fracture behavior of radiation cross-linked UHMWPE was compared to that of uncross-linked UHMWPE. The Rice and Sorensen model that utilizes mechanical parameters obtained from uniaxial tensile and compact tension tests was used to calculate the steady state J-integral fracture toughness, Jss, for radiation cross-linked UHMWPE. Jss decreased monotonically with increase in radiation dose. UHMWPE exhibited tough, ductile tearing behavior with stable crack growth when it was cross-linked using a gamma radiation dose of 0-50 kGy. However, in cross-linked UHMWPE irradiated to a dose of 100 and 200 kGy, unstable fracture occurred spontaneously upon attaining the initial crack driving force, J1c. This indicates that a high degree of cross-linking is less desirable for high-stress applications in orthopaedic implants. However, a substantial increase in J1c, even at a low degree of cross-linking, suggests that a low degree of cross-linking may be beneficial for resistance to delamination and catastrophic failure, both of which require an initiation step for the fracture to propagate in the material. This mechanical test should, however, be considered along with fatigue tests and joint simulator testing before determination of an appropriate amount of cross-linking for total joint replacement prostheses that experience high stresses.
Effect of ascorbic acid on prevention of hypercholesterolemia induced atherosclerosis.
Das, S; Ray, R; Snehlata; Das, N; Srivastava, L M
2006-04-01
The notion that oxidation of lipids and propagation of free radicals may contribute to the pathogenesis of atherosclerosis is supported by a large body of evidence. To circumvent the damage caused by oxygen free radicals, antioxidants are needed which provide the much needed neutralization of free radical by allowing the pairing of electrons. In this study we have investigated the effect of ascorbic acid, a water soluble antioxidant on the development of hypercholesterolemia induced atherosclerosis in rabbits. Rabbits were made hypercholesterolemic and atherosclerotic by feeding 100 mg cholesterol/day. Different doses of ascorbic acid were administered to these rabbits. Low dose of ascorbic acid (0.5 mg/100 g body weight/day) did not have any significant effect on the percent of total area covered by atherosclerotic plaque. However, ascorbic acid when fed at a higher dose (15 mg/100 g body weight/day) was highly effective in reducing the atherogenecity. With this dose the percent of total surface area covered by atherosclerotic plaque was significantly less (p < 0.001). This suggests that use of ascorbic acid may have great promise in the prevention of hypercholesterolemia induced atherosclerosis.
Quintupling Inhaled Glucocorticoids to Prevent Childhood Asthma Exacerbations.
Jackson, Daniel J; Bacharier, Leonard B; Mauger, David T; Boehmer, Susan; Beigelman, Avraham; Chmiel, James F; Fitzpatrick, Anne M; Gaffin, Jonathan M; Morgan, Wayne J; Peters, Stephen P; Phipatanakul, Wanda; Sheehan, William J; Cabana, Michael D; Holguin, Fernando; Martinez, Fernando D; Pongracic, Jacqueline A; Baxi, Sachin N; Benson, Mindy; Blake, Kathryn; Covar, Ronina; Gentile, Deborah A; Israel, Elliot; Krishnan, Jerry A; Kumar, Harsha V; Lang, Jason E; Lazarus, Stephen C; Lima, John J; Long, Dayna; Ly, Ngoc; Marbin, Jyothi; Moy, James N; Myers, Ross E; Olin, J Tod; Raissy, Hengameh H; Robison, Rachel G; Ross, Kristie; Sorkness, Christine A; Lemanske, Robert F
2018-03-08
Asthma exacerbations occur frequently despite the regular use of asthma-controller therapies, such as inhaled glucocorticoids. Clinicians commonly increase the doses of inhaled glucocorticoids at early signs of loss of asthma control. However, data on the safety and efficacy of this strategy in children are limited. We studied 254 children, 5 to 11 years of age, who had mild-to-moderate persistent asthma and had had at least one asthma exacerbation treated with systemic glucocorticoids in the previous year. Children were treated for 48 weeks with maintenance low-dose inhaled glucocorticoids (fluticasone propionate at a dose of 44 μg per inhalation, two inhalations twice daily) and were randomly assigned to either continue the same dose (low-dose group) or use a quintupled dose (high-dose group; fluticasone at a dose of 220 μg per inhalation, two inhalations twice daily) for 7 days at the early signs of loss of asthma control ("yellow zone"). Treatment was provided in a double-blind fashion. The primary outcome was the rate of severe asthma exacerbations treated with systemic glucocorticoids. The rate of severe asthma exacerbations treated with systemic glucocorticoids did not differ significantly between groups (0.48 exacerbations per year in the high-dose group and 0.37 exacerbations per year in the low-dose group; relative rate, 1.3; 95% confidence interval, 0.8 to 2.1; P=0.30). The time to the first exacerbation, the rate of treatment failure, symptom scores, and albuterol use during yellow-zone episodes did not differ significantly between groups. The total glucocorticoid exposure was 16% higher in the high-dose group than in the low-dose group. The difference in linear growth between the high-dose group and the low-dose group was -0.23 cm per year (P=0.06). In children with mild-to-moderate persistent asthma treated with daily inhaled glucocorticoids, quintupling the dose at the early signs of loss of asthma control did not reduce the rate of severe asthma exacerbations or improve other asthma outcomes and may be associated with diminished linear growth. (Funded by the National Heart, Lung, and Blood Institute; STICS ClinicalTrials.gov number, NCT02066129 .).
Gutiérrez Cardo, A L; Rodríguez Rodríguez, J R; Borrego Dorado, I; Navarro González, E; Tirado Hospital, J L; Vázquez Albertino, R
2007-01-01
To verify the existence of patients with treated differentiated thyroid cancer (DTC) with negative 131I whole-body scanning (WBS) and high serum thyroglobulin (Tg) in the follow-up who evolve towards normalization without other therapy interventions. Retrospective revision of the periodic examinations established in the protocol for patients with DTC, analyzing the levels of Tg found with IRMA annually in those with hormonal treatment and every 1-5 years in absence of previous hormonal treatment to WBS. Minimum surveillance of 2 years. Those who had elevated levels of Tg and WBS and other negative imaging tests in their course were selected. The characteristics of the patients selected were analysed in those whose Tg levels evolved to normalization without specific medical or surgical treatment (Group I) and those who did not reach normalization of Tg (Group II). A total of 130 patients (17.93 %) with high levels of Tg and negative WBS were detected. Group I: 31 patients (4.28 %), 11 men and 20 women; average age at the moment of the diagnosis of 33.4 years (rank: 5-60); average surveillance: 12.4 years (+/- 7.4). 27 papillary and 4 follicular carcinoma. Average ablation dose: 3.260 GBq (88,1 mCi); average total I131 dose: 6.850 GBq (185.13 mCi). Tg normalization average time: 8.2 years. Group II: 99 patients (13.65 %), 27 men and 72 women. Average age of 40.4 years (rank: 7-76). Average surveillance: 9.8 years. 86 papillary and 13 follicular carcinoma. Average ablation dose: 3.266 GBq (88.28 mCi); average total 131I dose: 9.363 GBq (253,06 mCi). Two of the patients in group I had negative PET-FDG. There were 13 patients in whom progressive reduction of the levels of thyroglobulin without reaching normalization with negative PET-FDG was detected. In patients with radiated DTC, deferred normalization of the levels of the serum thyroglobulin is possible. Empirical treatments cannot be considered the only factor that contributes to this result, which can occur without the administration of high-doses of 131I.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chibani, Omar; Williamson, Jeffrey F.; Todor, Dorin
2005-08-15
A Monte Carlo study is carried out to quantify the effects of seed anisotropy and interseed attenuation for {sup 103}Pd and {sup 125}I prostate implants. Two idealized and two real prostate implants are considered. Full Monte Carlo simulation (FMCS) of implants (seeds are physically and simultaneously simulated) is compared with isotropic point-source dose-kernel superposition (PSKS) and line-source dose-kernel superposition (LSKS) methods. For clinical pre- and post-procedure implants, the dose to the different structures (prostate, rectum wall, and urethra) is calculated. The discretized volumes of these structures are reconstructed using transrectal ultrasound contours. Local dose differences (PSKS versus FMCS and LSKSmore » versus FMCS) are investigated. The dose contributions from primary versus scattered photons are calculated separately. For {sup 103}Pd, the average absolute total dose difference between FMCS and PSKS can be as high as 7.4% for the idealized model and 6.1% for the clinical preprocedure implant. Similarly, the total dose difference is lower for the case of {sup 125}I: 4.4% for the idealized model and 4.6% for a clinical post-procedure implant. Average absolute dose differences between LSKS and FMCS are less significant for both seed models: 3 to 3.6% for the idealized models and 2.9 to 3.2% for the clinical plans. Dose differences between PSKS and FMCS are due to the absence of both seed anisotropy and interseed attenuation modeling in the PSKS approach. LSKS accounts for seed anisotropy but not for the interseed effect, leading to systematically overestimated dose values in comparison with the more accurate FMCS method. For both idealized and clinical implants the dose from scattered photons represent less than 1/3 of the total dose. For all studied cases, LSKS prostate DVHs overestimate D{sub 90} by 2 to 5% because of the missing interseed attenuation effect. PSKS and LSKS predictions of V{sub 150} and V{sub 200} are overestimated by up to 9% in comparison with the FMCS results. Finally, effects of seed anisotropy and interseed attenuation must be viewed in the context of other significant sources of dose uncertainty, namely seed orientation, source misplacement, prostate morphological changes and tissue heterogeneity.« less
Furlanetto, J; Eiermann, W; Marmé, F; Reimer, T; Reinisch, M; Schmatloch, S; Stickeler, E; Thomssen, C; Untch, M; Denkert, C; von Minckwitz, G; Lederer, B; Nekljudova, V; Weber, K; Loibl, S; Möbus, V
2016-11-01
In routine clinical practice, chemotherapy doses are frequently capped at a body surface area (BSA) of 2.0 m 2 or adjusted to an ideal weight for obese patients due to safety reasons. Between August 2004 and July 2008, a total of 3023 patients were enrolled in the GAIN study, a randomized phase III adjuvant trial, comparing two types of dose-dense (dd) regimen [epirubicin, docetaxel and cyclophosphamide (iddETC) versus epirubicin and cyclophosphamide (EC) followed by docetaxel (T) plus capecitabine (X)]. We retrospectively evaluated a total of 555 patients with a BMI of ≥30 for safety and outcome. Eighteen percent of all patients were obese: 31% of those received chemotherapy according to an unadjusted BSA. For the remaining patients, BSA was adjusted to ideal weight or was capped at 2.0 m 2 . A total of 15% of obese patients receiving full (unadjusted) dose of chemotherapy versus 6% of obese patients with an adjusted BSA experienced febrile neutropenia (P = 0.003) and 9% versus 3% high-grade thrombopenia (P = 0.002). Overall, 17% versus 10% had a thromboembolic event (P = 0.017), which was high grade in 13% versus 6%, respectively (P = 0.019), and 3% versus 0.3% high-grade hot flushes (P = 0.013). Dizziness (5% versus 11%; P = 0.016), diarrhea (19% versus 27%; P = 0.033) and an increase in serum creatinine (7% versus 14%; P = 0.019) were higher in the adjusted group. However, no differences in disease-free survival (DFS) and overall survival (OS) were observed between non-obese patients, obese patients receiving full-dose chemotherapy or according to an adjusted BSA [5-year DFS 81% (confidence interval 79% to 83%) versus 82% (75% to 87%) versus 81% (76% to 84%); P = 0.761; 5-year OS 90% (88% to 91%) versus 86% (80% to 91%) versus 88% (84% to 91%); P = 0.143]. Obese patients receiving dd chemotherapy according to their real BSA have a higher risk of developing severe toxicities without influencing survival. Therefore, a dose adjustment of intense dd chemotherapy should be carried out to avoid life-threatening complications. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Patel, Anup D
2014-02-01
In the United States, approximately one million people are evaluated annually in an emergency department (ED) for the diagnosis of a seizure or epilepsy. The highest percentages of these patients are less than five years of age. No studies have been performed on assessing potential variables associated with recurrent ED visits and/or unplanned hospitalizations for children with epilepsy. Institutional review board approval from Nationwide Children's Hospital was obtained prior to study initiation. An accountable care organization (ACO), Partner for Kids (PFK), database was searched for patients with the highest and the lowest number of ED visits and/or unplanned hospitalizations from 2007 through 2011 using ICD-9 codes of 345.xx and 780.39. The patients were stratified into a high and a low utilizer group. The total number of visits and their associated health care costs were noted for each patient. In total, 120 patients were included for review. Information on the total number of no-shows to outpatient neurology clinic visits and telephone calls to neurology triage nursing was noted. A chart review was performed by a pediatric epileptologist to determine if each individual patient was an appropriate candidate for an emergency seizure treatment. The dose of emergency seizure medication was cross-checked to the patient's actual dose during the time of ED or hospital presentation to determine if the dose given was high, low, or accurate based on dosing recommendations. Multivariable logistic regression was used to test the effects of factors. When controlling for other factors, patients who were given an incorrect or no emergency seizure dosing had a high probability of having multiple ED visits/unplanned hospitalizations compared with patients who were given correct dosing (odds ratio=11.28, 95% CI of odds ratio=(2.42, 52.63), p value<0.01 (p=0.0021)). Using a similar model, patients who experienced a higher number of no-shows to clinic visits had a higher probability of having multiple ED visits/unplanned hospitalizations (odds ratio=5.73 per 1 more number of no-show, 95% CI of odds ratio=(1.78, 18.44), p value<0.01 (p=0.0034)). Future studies are planned to target these risk factors with the goal of decreased ED and/or hospital utilization for children with epilepsy. Copyright © 2013 Elsevier Inc. All rights reserved.
Wong, Jeffrey Y C; Rosenthal, Joseph; Liu, An; Schultheiss, Timothy; Forman, Stephen; Somlo, George
2009-01-01
Total-body irradiation (TBI) has an important role in patients undergoing hematopoietic cell transplantation (HCT), but is associated with significant toxicities. Targeted TBI using helical tomotherapy results in reduced doses to normal organs, which predicts for reduced toxicities compared with standard TBI. Thirteen patients with multiple myeloma were treated in an autologous tandem transplantation Phase I trial with high-dose melphalan, followed 6 weeks later by total-marrow irradiation (TMI) to skeletal bone. Dose levels were 10, 12, 14, and 16 Gy at 2 Gy daily/twice daily. In a separate allogeneic HCT trial, 8 patients (5 with acute myelogenous leukemia, 1 with acute lymphoblastic leukemia, 1 with non-Hodgkin's lymphoma, and 1 with multiple myeloma) were treated with TMI plus total lymphoid irradiation plus splenic radiotherapy to 12 Gy (1.5 Gy twice daily) combined with fludarabine/melphalan. For the 13 patients in the tandem autologous HCT trial, median age was 54 years (range, 42-66 years). Median organ doses were 15-65% that of the gross target volume dose. Primarily Grades 1-2 acute toxicities were observed. Six patients reported no vomiting; 9 patients, no mucositis; 6 patients, no fatigue; and 8 patients, no diarrhea. For the 8 patients in the allogeneic HCT trial, median age was 52 years (range, 24-61 years). Grades 2-3 nausea, vomiting, mucositis, and diarrhea were observed. In both trials, no Grade 4 nonhematologic toxicity was observed, and all patients underwent successful engraftment. This study shows that TMI using helical tomotherapy is clinically feasible. The reduced acute toxicities observed compare favorably with those seen with standard TBI. Initial results are encouraging and warrant further evaluation as a method to dose escalate with acceptable toxicity or to offer TBI-containing regimens to patients unable to tolerate standard approaches.
Omidi, Arash; Riahinia, Narges; Montazer Torbati, Mohammad Bagher; Behdani, Mohammad-Ali
2014-01-01
Objectives: Acetaminophen (APAP) toxicity is known to be common and potentially fatal. This study aims to investigate the protective effects of hydroalcoholic extract, remaining from Crocus sativus petals (CSP) against APAP-induced hepatotoxicity by measuring the blood parameters and studying the histopathology of liver in male rats. Materials and Methods: Wister rats (24) were randomly assigned into four groups including: I) healthy, receiving normal saline; II) Intoxicated, receiving only APAP (600 mg/kg); III) pre-treated with low dose of CSP (10 mg /kg) and receiving APAP (600 mg/kg); IV) pre-treated with high dose of CSP (20 mg/kg) and receiving APAP (600 mg/kg). Results: The APAP treatment resulted in higher levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), and bilirubin, along with lower total protein and albumin concentration than the control group. The administration of CSP with a dose of 20 mg/kg was found to result in lower levels of AST, ALT and bilirubin, with a significant higher concentration of total protein and albumin. The histopathological results regarding liver pathology, revealed sever conditions including cell swelling, severe inflammation and necrosis in APAP-exposed rats, which was quiet contrasting compared to the control group. The pre-treated rats with low doses of CSP showed hydropic degeneration with mild necrosis in centrilobular areas of the liver, while the same subjects with high doses of CSP appeared to have only mild hepatocyte degeneration. Conclusions: Doses of 20 mg/kg of CSP ameliorates APAP–induced acute liver injury in rats. It was concluded that the antioxidant property of CSP resulted in reducing the oxidative stress complications of toxic levels of APAP in intoxicated rats. PMID:25386395
Morton, Ryan P; Reynolds, Renee M; Ramakrishna, Rohan; Levitt, Michael R; Hopper, Richard A; Lee, Amy; Browd, Samuel R
2013-10-01
In this study, the authors describe their experience with a low-dose head CT protocol for a preselected neurosurgical population at a dedicated pediatric hospital (Seattle Children's Hospital), the largest number of patients with this protocol reported to date. All low-dose head CT scans between October 2011 and November 2012 were reviewed. Two different low-dose radiation dosages were used, at one-half or one-quarter the dose of a standard head CT scan, based on patient characteristics agreed upon by the neurosurgery and radiology departments. Patient information was also recorded, including diagnosis and indication for CT scan. Six hundred twenty-four low-dose head CT procedures were performed within the 12-month study period. Although indications for the CT scans varied, the most common reason was to evaluate the ventricles and catheter placement in hydrocephalic patients with shunts (70%), followed by postoperative craniosynostosis imaging (12%). These scans provided adequate diagnostic imaging, and no patient required a follow-up full-dose CT scan as a result of poor image quality on a low-dose CT scan. Overall physician comfort and satisfaction with interpretation of the images was high. An additional 2150 full-dose head CT scans were performed during the same 12-month time period, making the total number of CT scans 2774. This value compares to 3730 full-dose head CT scans obtained during the year prior to the study when low-dose CT and rapid-sequence MRI was not a reliable option at Seattle Children's Hospital. Thus, over a 1-year period, 22% of the total CT scans were able to be converted to low-dose scans, and full-dose CT scans were able to be reduced by 42%. The implementation of a low-dose head CT protocol substantially reduced the amount of ionizing radiation exposure in a preselected population of pediatric neurosurgical patients. Image quality and diagnostic utility were not significantly compromised.
Fong, Alex; Serra, Allison E; Caballero, Deysi; Garite, Thomas J; Shrivastava, Vineet K
2017-08-01
Prolonged labor has been demonstrated to increase adverse maternal and neonatal outcome. A practice that may decrease the risk of prolonged labor is the modification of fluid intake during labor. Several studies demonstrated that increased hydration in labor as well as addition of dextrose-containing fluids may be associated with a decrease in length of labor. The purpose of our study was to characterize whether high-dose intravenous fluids, standard-dose fluids with dextrose, or high-dose fluids with dextrose show a difference in the duration of labor in nulliparas. Nulliparous subjects with singletons who presented in active labor were randomized to 1 of 3 groups of intravenous fluids: 250 mL/h of normal saline, 125 mL/h of 5% dextrose in normal saline, or 250 mL/h of 2.5% dextrose in normal saline. The primary outcome was total length of labor from initiation of intravenous fluid in vaginally delivered subjects. Secondary outcomes included cesarean delivery rate and length of second stage of labor, among other maternal and neonatal outcomes. In all, 274 subjects who met inclusion criteria were enrolled. There were no differences in baseline characteristics among the 3 groups. There was no difference in the primary outcome of total length of labor in vaginally delivered subjects among the 3 groups. First stage of labor duration, second stage of labor duration, and cesarean delivery rates were also equivalent. There were no differences identified in other secondary outcomes including clinical chorioamnionitis, postpartum hemorrhage, blood loss, Apgar scores, or neonatal intensive care admission. There is no difference in length of labor or delivery outcomes when comparing high-dose intravenous fluids, addition of dextrose, or use of high-dose intravenous fluids with dextrose in nulliparous women who present in active labor. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Ping, E-mail: ping.jiang@uksh.de; Baumann, René; Dunst, Juergen
Purpose: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. Methods and Materials: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immediate perioperative high-dose-rate brachytherapy; 3 patients had been previously treated with adjuvant external beam radiation therapy and presented with recurrences in the pretreated areas. Two or more different treatment modalities had been tried in all patients and had failed to achieve remission. After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volumemore » covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours after surgery, the other 2 fractions on the first postoperative day. Thus, a total dose of 18 Gy in 3 fractions was administered within 36 hours after the resection. Results: The treatment was feasible in all patients. No procedure-related complications (eg, secondary infections) occurred. Nineteen patients had keloid-related symptoms before treatment like pain and pruritus; disappearance of symptoms was noticed in all patients after treatment. After a median follow-up of 29.4 months (range, 7.9-72.4 months), 2 keloid recurrences and 2 mildly hypertrophied scars were observed. The local control rate was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. Conclusions: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest that brachytherapy may be advantageous in the management of high-risk keloids or as salvage treatment for failure after external beam therapy.« less
Song, Chunmei; Du, Juan; Ge, Hongjuan
2015-07-01
To study the effects o Hippophae rhamnoides fruits on serum lipids and liver protection in high-fat-diet rats. Wistar rats were divided into 5 groups,including control group, high lipid model group and Hippophae rhamnoides low-, medium- and high- dose groups,every group wastaken high-fat diet except control group. The rats in control group and high lipid group were lavaged with physiological saline. The doses of Hippophae rhamnoides in low, middle and high groups were determined based on the 1x, 5x, and 10x standard human doses (50 g/60 kg BW), respectively. The rat were orally given test sample respectively for 28 days, once a day. Observed the changes of serum lipids and hepatic tissues pathology. Compared with the control group, the serum levels of total cholesterol (TC), triglyceride (TG) and low density lipoprotein cholesterol (LDL-C) were increased significantly (P < 0.05) in high-fat-diet rats. Compared with the high lipid group, Hippophae rhamnoides of different doses could significantly reduce the content of TG (P < 0.01). Hippophae rhamnoides reduced the tendency of TC and LDL-C in serum and reduced the fatty degeneration of liver cells. The Hippophae rhamnoides fruits can reduce the level of serum lipids and prevent the occurrence of fatty liver, can be used for the prevention of hyperlipidemia.
Assessment of radiation doses from residential smoke detectors that contain americium-241
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Donnell, F.R.; Etnier, E.L.; Holton, G.A.
1981-10-01
External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq (3 ..mu..Ci) americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv (0.4 prem) to 20 nSv (2 ..mu..rem) for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 ..mu..Svmore » (0.0006 to 8 mrem) to total body and from 0.06 to 800 ..mu..Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft/sup 2/).« less
Sandrini, G; Cerbo, R; Del Bene, E; Ferrari, A; Genco, S; Grazioli, I; Martelletti, P; Nappi, G; Pinessi, L; Sarchielli, P; Tamburro, P; Uslenghi, C; Zanchin, G
2007-01-01
Aims and methods: In this double-blind, double-dummy, randomised, parallel group, multicentre study, the efficacy of dosing and re-dosing of a fixed combination of indomethacin, prochlorperazine and caffeine (Indoprocaf) was compared with encapsulated sumatriptan in the acute treatment of two migraine attacks. Additionally, in the group taking Indoprocaf, two different oral formulations were tested: effervescent tablets and encapsulated coated tablets. Results: Of 297 patients randomised (150 assigned to Indoprocaf and 147 to sumatriptan), 281 were included in the intention-to-treat efficacy analysis. The initial dosing of Indoprocaf and sumatriptan was similarly effective with pain-free rates higher than 30% (95% CI of odds-ratio: 0.57–1.28) and headache relief rates of about 60% (95% CI of odds-ratio: 0.82–1.84) with both the drugs. The efficacy of re-dosing of Indoprocaf as rescue medication was more effective than that of sumatriptan with pain-free values of 47% vs. 27% in the total attacks with a statistically significant difference in the first migraine attack in favour of Indoprocaf. The efficacy of re-dosing to treat a recurrence/relapse was very high without differences between the drugs (pain-free: 60% with Indoprocaf and 50% with sumatriptan in the total attacks). Indoprocaf and sumatriptan were well-tolerated. Conclusion: The study demonstrated that the efficacy of the initial dosing of Indoprocaf was not higher than that of sumatriptan, but that the strategy to use the lowest effective dose as soon as the headache occurred, followed by a second dose if the headache has not relieved or to treat a relapse, was very effective, especially with Indoprocaf. PMID:17627707
Ritter, M A; HamiltonCW
1975-01-01
Warfarin, low-dose heparin, or a combination of low-dose heparin and hydrocortisone was administered to 300 patients undergoing total hip replacement. The lowest incidence of thromboembolic (5 per cent) was attained with Warfarin. Further investigation into the method of administration of low-dose heparin is necessary before it can be used effectively as thromboembolism prophylaxis in total hip replacement patients. The addition of hydrocortisone was not found useful. PMID:1138642
Schver, Giovanna C R M; Lee, Ping I
2018-05-07
Under nonsink dissolution conditions, the kinetic-solubility profiles of amorphous solid dispersions (ASDs) based on soluble carriers typically exhibit so-called "spring-and-parachute" concentration-time behaviors. However, the kinetic-solubility profiles of ASDs based on insoluble carriers (including hydrogels) are known to show sustained supersaturation during nonsink dissolution through a matrix-regulated diffusion mechanism by which the supersaturation of the drug is built up gradually and sustained over an extended period without any dissolved polymers acting as crystallization inhibitors. Despite previous findings demonstrating the interplay between supersaturation rates and total doses on the kinetic-solubility profiles of soluble amorphous systems (including ASDs based on dissolution-regulated releases from soluble polymer carriers), the combined effects of supersaturation rates and doses on the kinetic-solubility profiles of ASDs based on diffusion-regulated releases from water-insoluble carriers have not been investigated previously. Thus, the objective of this study is to examine the impacts of total doses and supersaturation-generation rates on the resulting kinetic-solubility profiles of ASDs based on insoluble hydrogel carriers. We employed a previously established ASD-carrier system based on water-insoluble-cross-linked-poly(2-hydroxyethyl methacrylate) (PHEMA)-hydrogel beads and two poorly water soluble model drugs: the weakly acidic indomethacin (IND) and the weakly basic posaconazole (PCZ). Our results show clearly for the first time that by using the smallest-particle-size fraction and a high dose (i.e., above the critical dose), it is indeed possible to significantly shorten the duration of sustained supersaturation in the kinetic-solubility profile of an ASD based on a water-insoluble hydrogel carrier, such that it resembles the spring-and-parachute dissolution profiles normally associated with ASDs based on soluble carriers. This generates sufficiently rapid initial supersaturation buildup above the critical supersaturation, resulting in more rapid precipitation. Above this smallest-particle-size range, the matrix-diffusion-regulated nonlinear rate of drug release gets slower, which results in a more modest rate of supersaturation buildup, leading to a maximum supersaturation below the critical-supersaturation level without appreciable precipitation. The area-under-the-curve (AUC) values of the in vitro kinetic-solubility concentration-time profiles were used to correlate the corresponding trends in dissolution enhancement. There are observed monotonic increases in AUC values with increasing particle sizes for high-dose ASDs based on water-insoluble hydrogel matrixes, as opposed to the previously reported AUC maxima at some intermediate supersaturation rates or doses in soluble amorphous systems, whereas in the case of low-dose ASDs (i.e., below the critical dose levels), crystallization would be negligible, leading to sustained supersaturation with all particle sizes (i.e., eventually reaching the same maximum supersaturation) and the smallest particle size reaching the maximum supersaturation the fastest. As a result, the smallest particle sizes yield the largest AUC values in the case of low-dose ASDs based on water-insoluble hydrogel matrixes. In addition to probing the interplay between the supersaturation-generation rates and total doses in ASDs based on insoluble hydrogel carriers, our results further support the fact that through either increasing the hydrogel-particle size or lowering the total dose to achieve maximum supersaturation still below the critical-supersaturation level, it is possible to avoid drug precipitation so as to maintain sustained supersaturation.
Kilit, Celal; Koçak, Fatma Emel; Paşalı Kilit, Türkan
2017-04-01
Oxidative stress is increased in patients with acute myocardial infarction (AMI). Statins reduce oxidative stress independent of their effect in reducing low-density lipoprotein cholesterol (LDL-C). The aim of the present study was to compare the effects of atorvastatin and rosuvastatin on oxidative status by investigating serum paraoxonase, serum arylesterase, total oxidant status, total antioxidant status (TAS) and oxidative stress index (OSI) in patients with AMI. Seventy patients with AMI were randomized into 2 groups; total of 55 patients (19 females, 36 males) aged 32 to 86 years completed the study and were included in the analysis. Patients were treated with 80 mg atorvastatin or 40 mg rosuvastatin for 4 weeks. Lipid parameters and parameters of oxidative status were measured at admission and after 4-week statin treatment. After 4-week treatment, atorvastatin and rosuvastatin were associated with significant reduction in TAS, OSI, total cholesterol, and LDL-C levels. Serum paraoxonase level was significantly increased in both groups, while high-density lipoprotein cholesterol (HDL-C) level was significantly reduced in atorvastatin group. No statistically significant differences were found between atorvastatin and rosuvastatin in terms of actual difference in oxidative stress parameters. Atorvastatin and rosuvastatin have similar effects on oxidative status in patients with AMI. Rosuvastatin affected HDL-C level more favorably than atorvastatin.
Chin, Seung Joon; Moore, Grant A; Zhang, Mei; Clarke, Henry D; Spangehl, Mark J; Young, Simon W
2018-07-01
Obesity is an established risk factor for periprosthetic joint infections after total knee arthroplasty (TKA). In obese patients, a larger dose of prophylactic vancomycin based on actual body weight is required to reach therapeutic concentrations. It is unclear how tissue concentrations are affected when intraosseous regional administration (IORA) is used in this population. This study compared tissue concentrations of low-dose vancomycin via IORA vs actual body weight-adjusted systemic intravenous (IV) dose in primary TKA. Twenty-two patients with a body mass index (BMI) >35 undergoing TKA were randomized into 2 groups. The IV group received 15 mg/kg (maximum of 2 g) of systemic IV vancomycin and the IORA group received 500 mg vancomycin into the tibia. Subcutaneous fat and bone samples were taken at regular intervals. Tissue antibiotic concentrations were measured using liquid chromatography coupled with tandem mass spectrometry. A blood sample was taken 1 to 2 hours after tourniquet deflation to measure systemic concentration. The mean BMI was 41.1 in the IORA group and 40.1 in the IV systemic group. The overall mean tissue concentration in subcutaneous fat was 39.3 μg/g in the IORA group and 4.4 μg/g in the IV systemic group (P < .01). Mean tissue concentrations in bones were 34.4 μg/g in the IORA group and 6.1 μg/g in the IV systemic group (P < .01). Low-dose IORA was effective in the high-BMI population group, providing tissue concentrations of vancomycin 5-9 times higher than systemic administration. IORA optimizes timing of vancomycin administration and provides high tissue antibiotic concentrations during TKA in this high-risk patient group. Copyright © 2018 Elsevier Inc. All rights reserved.
Low Dose PET Image Reconstruction with Total Variation Using Alternating Direction Method.
Yu, Xingjian; Wang, Chenye; Hu, Hongjie; Liu, Huafeng
2016-01-01
In this paper, a total variation (TV) minimization strategy is proposed to overcome the problem of sparse spatial resolution and large amounts of noise in low dose positron emission tomography (PET) imaging reconstruction. Two types of objective function were established based on two statistical models of measured PET data, least-square (LS) TV for the Gaussian distribution and Poisson-TV for the Poisson distribution. To efficiently obtain high quality reconstructed images, the alternating direction method (ADM) is used to solve these objective functions. As compared with the iterative shrinkage/thresholding (IST) based algorithms, the proposed ADM can make full use of the TV constraint and its convergence rate is faster. The performance of the proposed approach is validated through comparisons with the expectation-maximization (EM) method using synthetic and experimental biological data. In the comparisons, the results of both LS-TV and Poisson-TV are taken into consideration to find which models are more suitable for PET imaging, in particular low-dose PET. To evaluate the results quantitatively, we computed bias, variance, and the contrast recovery coefficient (CRC) and drew profiles of the reconstructed images produced by the different methods. The results show that both Poisson-TV and LS-TV can provide a high visual quality at a low dose level. The bias and variance of the proposed LS-TV and Poisson-TV methods are 20% to 74% less at all counting levels than those of the EM method. Poisson-TV gives the best performance in terms of high-accuracy reconstruction with the lowest bias and variance as compared to the ground truth (14.3% less bias and 21.9% less variance). In contrast, LS-TV gives the best performance in terms of the high contrast of the reconstruction with the highest CRC.
Low Dose PET Image Reconstruction with Total Variation Using Alternating Direction Method
Yu, Xingjian; Wang, Chenye; Hu, Hongjie; Liu, Huafeng
2016-01-01
In this paper, a total variation (TV) minimization strategy is proposed to overcome the problem of sparse spatial resolution and large amounts of noise in low dose positron emission tomography (PET) imaging reconstruction. Two types of objective function were established based on two statistical models of measured PET data, least-square (LS) TV for the Gaussian distribution and Poisson-TV for the Poisson distribution. To efficiently obtain high quality reconstructed images, the alternating direction method (ADM) is used to solve these objective functions. As compared with the iterative shrinkage/thresholding (IST) based algorithms, the proposed ADM can make full use of the TV constraint and its convergence rate is faster. The performance of the proposed approach is validated through comparisons with the expectation-maximization (EM) method using synthetic and experimental biological data. In the comparisons, the results of both LS-TV and Poisson-TV are taken into consideration to find which models are more suitable for PET imaging, in particular low-dose PET. To evaluate the results quantitatively, we computed bias, variance, and the contrast recovery coefficient (CRC) and drew profiles of the reconstructed images produced by the different methods. The results show that both Poisson-TV and LS-TV can provide a high visual quality at a low dose level. The bias and variance of the proposed LS-TV and Poisson-TV methods are 20% to 74% less at all counting levels than those of the EM method. Poisson-TV gives the best performance in terms of high-accuracy reconstruction with the lowest bias and variance as compared to the ground truth (14.3% less bias and 21.9% less variance). In contrast, LS-TV gives the best performance in terms of the high contrast of the reconstruction with the highest CRC. PMID:28005929
Patel, Yogesh; Vadgama, Vishalkumar; Baxi, Seema; Chandrabhanu; Tripathi, B
2011-01-01
Our aim of the study was to evaluate the hypolipidemic activity of leaf juice of Catharanthus roseus (Linn.) G. Donn. in guinea pigs. Adult guinea pigs of either sex were divided into seven groups: group 1 - normal diet; group 2 - high fat diet; group 3 and 4 - normal diet plus leaf juice of Catharanthus roseus (Linn.) G. Donn. in the dose of 0.5 and 1 mL/kg, respectively; group 5 and 6- high fat diet with leaf juice of Catharanthus roseus (Linn.) G. Donn. in the dose of 0.5 and 1 mL/kg, respectively; group 7 - high fat diet plus atorvastatin (3 mg/kg). Above diet treatment was given for six weeks and drug was given during last three weeks. Serum lipid profile (total cholesterol, triglycerides, LDL-c, VLDL-c, HDL-c) was performed in each group of animals before and at the end of six weeks. Histological study of aorta, liver and kidney was done in group 1, 2, 6 and 7 and blood cell count was done in animals that were treated juice of C. roseus (Linn.) G. Donn. before and after juice administration. Simultaneous administration of leaf juice of C. roseus (Linn.) G. Donn. in the dose of 0.5 mL/kg prevents the rise of serum lipid parameters and decreases the fatty changes in the tissue induced by high fat diet, whereas in the dose of 1 mL/kg not only counteracts the elevation, but also significantly (p < 0.05) reduces the serum level LDL-c and the ratio of total cholesterol and HDL-c. Leaf juice of C. roseus (Linn.) G. Donn. possesses significant lipid lowering and anti atherosclerotic activity.
Low Dose CT Reconstruction via Edge-preserving Total Variation Regularization
Tian, Zhen; Jia, Xun; Yuan, Kehong; Pan, Tinsu; Jiang, Steve B.
2014-01-01
High radiation dose in CT scans increases a lifetime risk of cancer and has become a major clinical concern. Recently, iterative reconstruction algorithms with Total Variation (TV) regularization have been developed to reconstruct CT images from highly undersampled data acquired at low mAs levels in order to reduce the imaging dose. Nonetheless, the low contrast structures tend to be smoothed out by the TV regularization, posing a great challenge for the TV method. To solve this problem, in this work we develop an iterative CT reconstruction algorithm with edge-preserving TV regularization to reconstruct CT images from highly undersampled data obtained at low mAs levels. The CT image is reconstructed by minimizing an energy consisting of an edge-preserving TV norm and a data fidelity term posed by the x-ray projections. The edge-preserving TV term is proposed to preferentially perform smoothing only on non-edge part of the image in order to better preserve the edges, which is realized by introducing a penalty weight to the original total variation norm. During the reconstruction process, the pixels at edges would be gradually identified and given small penalty weight. Our iterative algorithm is implemented on GPU to improve its speed. We test our reconstruction algorithm on a digital NCAT phantom, a physical chest phantom, and a Catphan phantom. Reconstruction results from a conventional FBP algorithm and a TV regularization method without edge preserving penalty are also presented for comparison purpose. The experimental results illustrate that both TV-based algorithm and our edge-preserving TV algorithm outperform the conventional FBP algorithm in suppressing the streaking artifacts and image noise under the low dose context. Our edge-preserving algorithm is superior to the TV-based algorithm in that it can preserve more information of low contrast structures and therefore maintain acceptable spatial resolution. PMID:21860076
Esteves, Sandro C; Schertz, Joan C; Verza, Sidney; Schneider, Danielle T; Zabaglia, Silval FC
2009-01-01
Background Over the last several decades, as a result of an evolution in manufacturing processes, a marked development has been made in the field of gonadotropins for ovarian stimulation. Initially, therapeutic gonadotropins were produced from a simple process of urine extraction and purification; now they are produced via a complex system involving recombinant technology, which yields gonadotropins with high levels of purity, quality, and consistency. Methods A retrospective analysis of 865 consecutive intracytoplasmic sperm injection (ICSI) cycles of controlled ovarian hyperstimulation (COH) compared the clinical efficacy of three gonadotropins (menotropin [hMG; n = 299], highly-purified hMG [HP-hMG; n = 330] and follitropin alfa [r-hFSH; n = 236]) for ovarian stimulation after pituitary down-regulation. The endpoints were live birth rates and total doses of gonadotropin per cycle and per pregnancy. Results Laboratory and clinical protocols remained unchanged over time, except for the type of gonadotropin used, which was introduced sequentially (hMG, then HP-hMG, and finally r-hFSH). Live birth rates were not significantly different for hMG (24.4%), HP-hMG (32.4%) and r-hFSH (30.1%; p = 0.09) groups. Total dose of gonadotropin per cycle was significantly higher in the hMG (2685 +/- 720 IU) and HP-hMG (2903 +/- 867 IU) groups compared with the r-hFSH-group (2268 +/- 747 IU; p < 0.001). Total dose of gonadotropin required to achieve clinical pregnancy was 15.7% and 11.0% higher for the hMG and HP-hMG groups, respectively, compared with the r-hFSH group, and for live births, the differences observed were 45.3% and 19.8%, respectively. Conclusion Although similar live birth rates were achieved, markedly lower doses of r-hFSH were required compared with hMG or HP-hMG. PMID:19828024
Manikandan, A.; Biplab, Sarkar; David, Perianayagam A.; Holla, R.; Vivek, T. R.; Sujatha, N.
2011-01-01
For high dose rate (HDR) brachytherapy, independent treatment verification is needed to ensure that the treatment is performed as per prescription. This study demonstrates dosimetric quality assurance of the HDR brachytherapy using a commercially available two-dimensional ion chamber array called IMatriXX, which has a detector separation of 0.7619 cm. The reference isodose length, step size, and source dwell positional accuracy were verified. A total of 24 dwell positions, which were verified for positional accuracy gave a total error (systematic and random) of –0.45 mm, with a standard deviation of 1.01 mm and maximum error of 1.8 mm. Using a step size of 5 mm, reference isodose length (the length of 100% isodose line) was verified for single and multiple catheters of same and different source loadings. An error ≤1 mm was measured in 57% of tests analyzed. Step size verification for 2, 3, 4, and 5 cm was performed and 70% of the step size errors were below 1 mm, with maximum of 1.2 mm. The step size ≤1 cm could not be verified by the IMatriXX as it could not resolve the peaks in dose profile. PMID:21897562
[Effects of blueberry on apoptosis and expression of Bcl-2 and Bax in HSC-T6].
Lu, Shuang; Cheng, Mingliang; Yang, Demeng; Liu, Yang; Guan, Li; Wu, Jun
2015-08-18
To investigate the effects of blueberry on the apoptosis, expression of Bcl-2 and Bax in rat hepatic stellate cell (HSC-T6). 10% blueberry serum at low, middle and high dose, 10% Fu-Fang-Bie-Jia-Ruan-Gan tablet serum and 10% saline serum were prepared by method of serum pharmacology. Subcultured HSC-T6 was divided into saline serum control group, blueberry serum at low, middle, high dose and Fu-Fang-Bie-Jia-Ruan-Gan tablet serum group, and then was respectively incubated at different dose of 10% blueberry serum, 10% Fu-Fang-Bie-Jia-Ruan-Gan tablet serum and 10% saline serum for 72 hours.Apoptosis of HSC-T6 was detected using flow cytometry with annexin V FITC/PI double staining. The expression of Bcl-2 and Bax in HSC-T6 were examined using immunocytochemistry and Western blotting, respectively. There was no significant difference for HSC-T6 Bax protein expression in the low, middle and high dose blueberry serum groups, compared with saline serum control group, respectively.In the high-dose blueberry serum group HSC-T6 early and total apoptosis rate increased significantly compared with the saline serum control group (5.55% ± 0.98% vs 2.53% ± 0.46%, 7.01% ± 1.05% vs 2.96% ± 0.81%, both P<0.05); Bcl-2 protein expression was significantly decreased (A value, 82 ± 35 vs 51 ± 13, P<0.05); Bcl-2/Bax ratio was significantly decreased (0.26 ± 0.02 vs 0.46 ± 0.03, P<0.05); HSC-T6 early and total apoptosis rate, Bcl-2 expression and Bcl-2/Bax ratio in the low and the middle dose blueberry serum group showed no significant difference with the saline serum control group. Blueberry can induce HSC-T6 apoptosis by down-regulating Bcl-2 expression and decreasing the ratio of Bcl-2/Bax in HSC-T6 cells, so it may have potential interference effects on hepatic fibrosis.
Radiation damage and sensitization effects on thermoluminescence of LiF:Mg,Ti (TLD-700)
NASA Astrophysics Data System (ADS)
Farag, M. A.; Sadek, A. M.; Shousha, Hany. A.; El-Hagg, A. A.; Atta, M. R.; Kitis, G.
2017-09-01
The radiation damage effects and enhancement the thermoluminescence (TL) efficiency of LiF:Mg,Ti (TLD-700)dosimeters via sensitization method were discussed. Attempts to eliminate the effects of damage and sensitization were made using different types of annealing processes. The results showed that after irradiating the dosimeters with dose > 250 Gy of 60Co gamma source, damage effects were observed. The sensitivity of the total area under the curve was decreased by a factor of ∼0.5 after irradiation at a pre-test dose of 2 kGy. However, the effects of radiation damage on each glow-peak are different. The glow-peak 2 was the only peak that was not affected by the high-dose irradiation. It has been shown that the degree of the radiation damage effect is related to the maximum dose-response function, f(D)max of the glow-peak. In general, significant radiation damage effects were observed for the glow-peaks of high f(D)max . Post-irradiation anneal at 280 °C for 30 min causes dramatic effects on the shape of the glow-curve and as well as on the sensitivity of the dosimeters. An increasing by a factor of ∼35 in the sensitivity of the total area under the curve was observed at a pre-test dose of 2 kGy. Improving the sensitivity of peak 7 by a factor of∼22 was the dominant factor in increasing the sensitivity of the dosimeters. On the other hand, an increasing by factors of ∼2.5 and ∼4 was found for peaks 2 and 5 respectively. On the other hand, a decreasing by a factor ∼0.5 was observed for peaks 3 and 4. At pre-test dose levels >250 Gy, a very strange and high intensity tail was observed in the high-temperature region of the glow-curves. The readout anneal was not enough to remove this tail. While, the furnace anneal could eliminate the sensitization effects but not the radiation damage effects on the sensitivity of the dosimeters.
Electrically-inactive phosphorus re-distribution during low temperature annealing
NASA Astrophysics Data System (ADS)
Peral, Ana; Youssef, Amanda; Dastgheib-Shirazi, Amir; Akey, Austin; Peters, Ian Marius; Hahn, Giso; Buonassisi, Tonio; del Cañizo, Carlos
2018-04-01
An increased total dose of phosphorus (P dose) in the first 40 nm of a phosphorus diffused emitter has been measured after Low Temperature Annealing (LTA) at 700 °C using the Glow Discharge Optical Emission Spectrometry technique. This evidence has been observed in three versions of the same emitter containing different amounts of initial phosphorus. A stepwise chemical etching of a diffused phosphorus emitter has been carried out to prepare the three types of samples. The total P dose in the first 40 nm increases during annealing by 1.4 × 1015 cm-2 for the sample with the highly doped emitter, by 0.8 × 1015 cm-2 in the middle-doped emitter, and by 0.5 × 1015 cm-2 in the lowest-doped emitter. The presence of surface dislocations in the first few nanometers of the phosphorus emitter might play a role as preferential sites of local phosphorus gettering in phosphorus re-distribution, because the phosphorus gettering to the first 40 nm is lower when this region is etched stepwise. This total increase in phosphorus takes place even though the calculated electrically active phosphorus concentration shows a reduction, and the measured sheet resistance shows an increase after annealing at a low temperature. The reduced electrically active P dose is around 0.6 × 1015 cm-2 for all the emitters. This can be explained with phosphorus-atoms diffusing towards the surface during annealing, occupying electrically inactive configurations. An atomic-scale visual local analysis is carried out with needle-shaped samples of tens of nm in diameter containing a region of the highly doped emitter before and after LTA using Atom Probe Tomography, showing phosphorus precipitates of 10 nm and less before annealing and an increased density of larger precipitates after annealing (25 nm and less).
Custom-made micro applicators for high-dose-rate brachytherapy treatment of chronic psoriasis.
Buzurovic, Ivan M; O'Farrell, Desmond A; Bhagwat, Mandar S; Hansen, Jorgen L; Harris, Thomas C; Friesen, Scott; Cormack, Robert A; Devlin, Phillip M
2017-06-01
In this study, we present the treatment of the psoriatic nail beds of patients refractory to standard therapies using high-dose-rate (HDR) brachytherapy. The custom-made micro applicators (CMMA) were designed and constructed for radiation dose delivery to small curvy targets with complicated topology. The role of the HDR brachytherapy treatment was to stimulate the T cells for an increased immune response. The patient diagnosed with psoriatic nail beds refractory to standard therapies received monthly subunguinal injections that caused significant pain and discomfort in both hands. The clinical target was defined as the length from the fingertip to the distal interphalangeal joint. For the accurate and reproducible setup in the multi-fractional treatment delivery, the CMMAs were designed. Five needles were embedded into the dense plastic mesh and covered with 5 mm bolus material for each micro applicator. Five CMMAs were designed, resulting in the usage of 25 catheters in total. The prescription dose was planned to the depth of the anterior surface of the distal phalanx, allowing for the sparing of the surrounding tissue. The total number of the active dwell positions was 145 with step size of 5 mm. The total treatment time was 115 seconds with a 7.36 Ci activity of the 192 Ir source. The treatment resulted in good pain control. The patient did not require further injections to the nail bed. After this initial treatment, additional two patients with similar symptoms received HDR brachytherapy. The treatment outcome was favorable in all cases. The first HDR brachytherapy treatment of psoriasis of the nail bed is presented. The initial experience revealed that brachytherapy treatment was well-tolerated and resulted in adequate control of the disease. A larger cohort of patients will be required for additional conclusions related to the long-term clinical benefits.
Lopez-Toledano, Miguel A; Thorsteinsson, Thorsteinn; Daak, Ahmed; Maki, Kevin C; Johns, Colleen; Rabinowicz, Adrian L; Sancilio, Frederick D
2017-03-01
The US Food and Drug Administration has approved several highly purified ω-3 fatty acid prescription drugs for the treatment of severe hypertriglyceridemia. These differ in the amounts and forms of docosahexaenoic acid (DHA) and/or eicosapentaenoic acid (EPA). This study compared the bioavailability of SC401 (1530 mg EPA-ethyl esters [EEs] and DHA-EEs plus Advanced Lipid Technologies ⁎ [ALT † ], a proprietary lipid-delivery platform to improve absorption), with. Lovaza ‡ (3600 mg ω-3, primarily EPA-EEs and DHA-EEs) under low-fat feeding conditions. This was a Phase I, randomized, open-label, single-dose, 2-way crossover study in healthy participants housed from day -3 to day 2 in each treatment period. Blood samples for pharmacokinetic measurements were collected before and after dosing, and safety profile and tolerability were assessed. In unadjusted analyses, SC401 had 5% lower C max and approximately the same AUC 0-last of EPA + DHA total lipids compared with Lovaza. When adjusted for baseline, SC401 had ~6% higher C max and 18% higher AUC 0-last for EPA + DHA total lipids, and dose- and baseline-adjusted analyses found that SC401 had ~149% higher C max and 178% higher AUC 0-last than Lovaza for EPA + DHA total lipids. The T max was also substantially longer with Lovaza (~10 hours) than with SC401 (~6 hours). These results indicate that SC401, an ω-3 acid EE formulation containing ALT † achieved high bioavailability of EPA and DHA, at a lower dose (1530 mg) than Lovaza (3600 mg), under low-fat feeding conditions. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.
Chen, Ming; Hayman, James A; Ten Haken, Randall K; Tatro, Daniel; Fernando, Shaneli; Kong, Feng-Ming
2006-01-01
To report the results of high-dose conformal irradiation and examine incidental nodal irradiation and nodal failure in patients with inoperable early-stage non-small-cell lung cancer (NSCLC). This analysis included patients with inoperable CT-staged T1-3N0M0 NSCLC treated on our prospective dose-escalation trial. Patients were treated with radiation alone (total dose, 63-102.9 Gy in 2.1-Gy daily fractions) with a three-dimensional conformal technique without intentional nodal irradiation. Bilateral highest mediastinal and upper/lower paratracheal, prevascular and retrotracheal, sub- and para-aortic, subcarinal, paraesophageal, and ipsilateral hilar regions were delineated individually. Nodal failure and doses of incidental irradiation were studied. The potential median follow-up was 104 months. For patients who completed protocol treatment, median survival was 31 months. The actuarial overall survival rate was 86%, 61%, 43%, and 21% and the cause-specific survival rate was 89%, 70%, 53%, and 35% at 1, 2, 3, and 5 years, respectively. Weight loss (p = 0.008) and radiation dose in Gy (p = 0.013) were significantly associated with overall survival. In only 22% and 13% of patients examined did ipsilateral hilar and paratracheal (and subaortic for left-sided tumor) nodal regions receive a dose of > or = 40 Gy, respectively. Less than 10% of all other nodal regions received a dose of > or = 40 Gy. No patients failed initially at nodal sites. Radiation dose is positively associated with overall survival in patients with medically inoperable T1-3N0 NSCLC, though long-term results remain poor. The nodal failure rate is low and does not seem to be due to high-dose incidental irradiation.
NASA Astrophysics Data System (ADS)
Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C. C. M.; Bel, Arjan; Alderliesten, Tanja
2016-03-01
The use of 4D cone-beam computed tomography (CBCT) and fiducial markers for guidance during radiation therapy of mobile tumors is challenging due to the trade-off between image quality, imaging dose, and scanning time. We aimed to investigate the visibility of markers and the feasibility of marker-based 4D registration and manual respiration-induced marker motion quantification for different CBCT acquisition settings. A dynamic thorax phantom and a patient with implanted gold markers were included. For both the phantom and patient, the peak-to-peak amplitude of marker motion in the cranial-caudal direction ranged from 5.3 to 14.0 mm, which did not affect the marker visibility and the associated marker-based registration feasibility. While using a medium field of view (FOV) and the same total imaging dose as is applied for 3D CBCT scanning in our clinic, it was feasible to attain an improved marker visibility by reducing the imaging dose per projection and increasing the number of projection images. For a small FOV with a shorter rotation arc but similar total imaging dose, streak artifacts were reduced due to using a smaller sampling angle. Additionally, the use of a small FOV allowed reducing total imaging dose and scanning time (~2.5 min) without losing the marker visibility. In conclusion, by using 4D CBCT with identical or lower imaging dose and a reduced gantry speed, it is feasible to attain sufficient marker visibility for marker-based 4D setup verification. Moreover, regardless of the settings, manual marker motion quantification can achieve a high accuracy with the error <1.2 mm.
Al-lela, Omer Qutaiba B; Bahari, Mohd Baidi; Al-abbassi, Mustafa G; Salih, Muhannad R M; Basher, Amena Y
2012-06-06
The immunization status of children is improved by interventions that increase community demand for compulsory and non-compulsory vaccines, one of the most important interventions related to immunization providers. The aim of this study is to evaluate the activities of immunization providers in terms of activities time and cost, to calculate the immunization doses cost, and to determine the immunization dose errors cost. Time-motion and cost analysis study design was used. Five public health clinics in Mosul-Iraq participated in the study. Fifty (50) vaccine doses were required to estimate activities time and cost. Micro-costing method was used; time and cost data were collected for each immunization-related activity performed by the clinic staff. A stopwatch was used to measure the duration of activity interactions between the parents and clinic staff. The immunization service cost was calculated by multiplying the average salary/min by activity time per minute. 528 immunization cards of Iraqi children were scanned to determine the number and the cost of immunization doses errors (extraimmunization doses and invalid doses). The average time for child registration was 6.7 min per each immunization dose, and the physician spent more than 10 min per dose. Nurses needed more than 5 min to complete child vaccination. The total cost of immunization activities was 1.67 US$ per each immunization dose. Measles vaccine (fifth dose) has a lower price (0.42 US$) than all other immunization doses. The cost of a total of 288 invalid doses was 744.55 US$ and the cost of a total of 195 extra immunization doses was 503.85 US$. The time spent on physicians' activities was longer than that spent on registrars' and nurses' activities. Physician total cost was higher than registrar cost and nurse cost. The total immunization cost will increase by about 13.3% owing to dose errors. Copyright © 2012 Elsevier Ltd. All rights reserved.
Liao, Shang-Chih; Hung, Cheng-Chieh; Lee, Chien-Te; Lee, Chih-Hsiung; Lee, Chin-Chan; Lin, Chun-Liang; Sun, Chiao-Yin; Cheng, Ben-Chung; Yang, Chih-Chao; Wu, Chien-Hsing; Chen, Jin-Bor
2016-08-01
This multicenter study was designed to assess the hemoglobin (Hb) stability and conversion ratio of the switch from epoetin beta to darbepoetin alfa in Taiwanese hemodialysis (HD) patients. A total of 135 HD patients were enrolled and randomized with intravenous darbepoetin alfa or epoetin beta. The study duration was 24 weeks. Equivalent doses and conversion ratios were assessed with respect to Hb stratification: low Hb (≥8.0 g/dL to ≤10.0 g/dL) and high Hb (>10.0 g/dL to ≤11.0 g/dL). The results showed stable Hb levels in the study period. At week 24, the conversion ratio was higher for high Hb than low Hb (296.4 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa. vs. 277.2 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa). In conclusion, the conversion ratio in the present study was higher than 1 µg: 200 IU for darbepoetin alfa: epoetin for treating anemia in Taiwanese HD patients. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Dolton, Michael J.; Perera, Vidya; Pont, Lisa G.
2014-01-01
Terbinafine is increasingly used in combination with other antifungal agents to treat resistant or refractory mycoses due to synergistic in vitro antifungal activity; high doses are commonly used, but limited data are available on systemic exposure, and no assessment of pharmacodynamic target attainment has been made. Using a physiologically based pharmacokinetic (PBPK) model for terbinafine, this study aimed to predict total and unbound terbinafine concentrations in plasma with a range of high-dose regimens and also calculate predicted pharmacodynamic parameters for terbinafine. Predicted terbinafine concentrations accumulated significantly during the first 28 days of treatment; the area under the concentration-time curve (AUC)/MIC ratios and AUC for the free, unbound fraction (fAUC)/MIC ratios increased by 54 to 62% on day 7 of treatment and by 80 to 92% on day 28 compared to day 1, depending on the dose regimen. Of the high-dose regimens investigated, 500 mg of terbinafine taken every 12 h provided the highest systemic exposure; on day 7 of treatment, the predicted AUC, maximum concentration (Cmax), and minimum concentration (Cmin) were approximately 4-fold, 1.9-fold, and 4.4-fold higher than with a standard-dose regimen of 250 mg once daily. Close agreement was seen between the concentrations predicted by the PBPK model and the observed concentrations, indicating good predictive performance. This study provides the first report of predicted terbinafine exposure in plasma with a range of high-dose regimens. PMID:24126579
Amato, Arnaldo; Radaelli, Franco; Paggi, Silvia; Terruzzi, Vittorio
2010-03-01
Patients' compliance with and tolerance of large-volume polyethylene glycol electrolyte solution (PEG-ES) have prompted continuous investigation with alternative forms of cleansing. High-dose senna is superior to PEG-ES for the quality of bowel cleansing, patient compliance, and tolerance, but its acceptance may be influenced by the incidence of abdominal pain. We hypothesized that a combination of half doses of PEG-ES and senna could minimize the incidence of abdominal pain without affecting the quality of bowel preparation. This randomized, investigator-blinded trial has been conducted on consecutive outpatients scheduled for elective colonoscopy at a single community-based hospital. Patients were randomly assigned to receive either 12 tablets of 12 mg senna and 2 l of PEG-ES (half-dose group, HDG) or 24 tablets of senna divided in two doses (senna group, SG) the day before colonoscopy. The main outcome measures were the quality of colon cleansing (Aronchick scoring scale) and the incidence of preparation-related abdominal pain. Secondary outcome measures were patients' compliance with the cleansing regimen, overall tolerability, prevalence of predefined side effects, and quality of right colon cleansing. A total of 296 patients were enrolled (HDG=151 and SG=145). Overall cleansing was excellent to good in 90.1 and 88.3% patients in HDG and SG, respectively (P=0.62). Preparation-related moderate-to-severe abdominal pain was reported by 6% patients in HDG and 15.2% in SG (P=0.009). No significant differences were observed for secondary outcomes. The regimen combining half doses of PEG-ES and senna provides high-quality bowel preparation and acceptable patient tolerance, with less abdominal pain compared with high-dose senna.
Paulu, D; Alaei, P
2012-06-01
To evaluate the ability of treatment planning algorithm to accurately predict dose delivered at the interface of high density implanted devices. A high density (7.6 g/cc) Cobalt-Chromium-Molybdenum hip prosthesis was molded into an epoxy-based cylindrical leg phantom. The phantom was designed to be separated in half to access the prosthesis and to place the TLDs. Using MVCT to image the apparatus, a simple treatment plan was developed using the Philips Pinnacle treatment planning system. Wires were placed in the molded epoxy to allow for accurate definition of measurement sites (TLD positions) along the surface of the prosthesis. Micro-cube TLDs (1 mm 3 ) were placed at six measurement locations for which the dose had been calculated by the treatment planning system. An Elekta Synergy linear accelerator was used to deliver a 400 cGy plan to the phantom with 6 MV photons in a single fraction. A total of four 10 cm × 21 cm fields were used at 0, 90, 180, and 270 degree gantry rotations. Initial results indicate that the measured dose is 7-17% lower than the dose calculated by the treatment planning system. Further study using high energy beams are also in progress. Initial results indicate that the treatment planning system does predict the dose near a high density prosthetic device within 10-15% but underestimates the dose. The results of this study could help in designing treatment plans which would reduce the uncertainty of the dose delivered in the vicinity of prosthetic hip implants and similar devices. © 2012 American Association of Physicists in Medicine.
Chung, Hyewon; Oh, Jaeseong; Yoon, Seo Hyun; Yu, Kyung-Sang; Cho, Joo-Youn; Chung, Jae-Yong
2018-01-01
The aim of this study was to explore the pharmacokinetic-pharmacodynamic (PK-PD) relationship of metformin on glucose levels after the administration of 250 mg and 1000 mg of metformin in healthy volunteers. A total of 20 healthy male volunteers were randomized to receive two doses of either a low dose (375 mg followed by 250 mg) or a high dose (1000 mg followed by 1000 mg) of metformin at 12-h intervals. The pharmacodynamics of metformin was assessed using oral glucose tolerance tests before and after metformin administration. The PK parameters after the second dose were evaluated through noncompartmental analyses. Four single nucleotide polymorphisms in MATE1, MATE2-K, and OCT2 were genotyped, and their effects on PK characteristics were additionally evaluated. The plasma exposure of metformin increased as the metformin dose increased. The mean values for the area under the concentration-time curve from dosing to 12 hours post-dose (AUC0-12h) were 3160.4 and 8808.2 h·μg/L for the low- and high-dose groups, respectively. Non-linear relationships were found between the glucose-lowering effect and PK parameters with a significant inverse trend at high metformin exposure. The PK parameters were comparable among subjects with the genetic polymorphisms. This study showed a non-linear PK-PD relationship on plasma glucose levels after the administration of metformin. The inverse relationship between systemic exposure and the glucose-lowering effect at a high exposure indicates a possible role for the intestines as an action site for metformin. ClinicalTrials.gov NCT02712619.
High-Dose Citalopram and Escitalopram and the Risk of Out-of-Hospital Death.
Ray, Wayne A; Chung, Cecilia P; Murray, Katherine T; Hall, Kathi; Stein, C Michael
2017-02-01
Studies demonstrating that higher doses of citalopram (> 40 mg) and escitalopram (> 20 mg) prolong the corrected QT interval prompted regulatory agency warnings, which are controversial, given the absence of confirmatory clinical outcome studies. We compared the risk of potential arrhythmia-related deaths for high doses of these selective serotonin reuptake inhibitors (SSRIs) to that for equivalent doses of fluoxetine, paroxetine, and sertraline. The Tennessee Medicaid retrospective cohort study included 54,220 persons 30-74 years of age without cancer or other life-threatening illness who were prescribed high-dose SSRIs from 1998 through 2011. The mean age was 47 years, and 76% were female. Demographic characteristics and comorbidity for individual SSRIs were comparable. Because arrhythmia-related deaths are typically sudden and occur outside the hospital, we analyzed out-of-hospital sudden unexpected death as well as sudden cardiac deaths, a more specific indicator of proarrhythmic effects. The adjusted risk of sudden unexpected death for citalopram did not differ significantly from that for the other SSRIs. The respective hazard ratios (HRs) for citalopram versus escitalopram, fluoxetine, paroxetine, and sertraline were 0.84 (95% CI, 0.40-1.75), 1.24 (95% CI, 0.75-2.05), 0.75 (95% CI, 0.45-1.24), and 1.53 (95% CI, 0.91-2.55). There were no significant differences for sudden cardiac death or all study deaths, nor were there significant differences among high-risk patients (≥ 60 years of age, upper quartile baseline cardiovascular risk). Escitalopram users had no significantly increased risk for any study end point. We found no evidence that risk of sudden unexpected death, sudden cardiac death, or total mortality for high-dose citalopram and escitalopram differed significantly from that for comparable doses of fluoxetine, paroxetine, and sertraline. © Copyright 2016 Physicians Postgraduate Press, Inc.
High-Dose Citalopram and Escitalopram and the Risk of Out-of-Hospital Death
Ray, Wayne A.; Chung, Cecilia P.; Murray, Katherine T.; Hall, Kathi; Stein, C. Michael
2018-01-01
Objective Studies demonstrating higher doses of citalopram (>40mg) and escitalopram (>20mg) prolong the QTc interval prompted regulatory agency warnings, which are controversial, given the absence of confirmatory clinical outcome studies. We compared the risk of potential arrhythmia-related deaths for high doses of these SSRIs to that for equivalent doses of fluoxetine, paroxetine, and sertraline. Method The Tennessee Medicaid retrospective cohort study included 54,220 persons 30–74 years of age without cancer or other life-threatening illness prescribed high-dose SSRIs. The mean age was 47 years and 76% were female. Demographic characteristics and comorbidity for individual SSRIs were comparable. Because arrhythmia-related deaths are typically sudden and occur outside the hospital, we analyzed out-of-hospital sudden unexpected death as well as sudden cardiac deaths, a more specific indicator of pro-arrhythmic effects. Results The adjusted risk of sudden unexpected death for citalopram did not differ significantly from that for the other SSRIs. The respective hazard ratios (HRs) for citalopram versus escitalopram, fluoxetine, paroxetine, and sertraline were 0.84 (95% confidence interval [CI], 0.40–1.75), 1.24 (0.75–2.05), 0.75 (0.45–1.24), and 1.53 (0.91–2.55). There were no significant differences for sudden cardiac death or all study deaths, nor were there significant differences among high-risk patients (≥60 years of age, upper quartile baseline cardiovascular risk). Escitalopram users had no significantly increased risk for any study endpoint. Conclusions We found no evidence that risk of sudden unexpected death, sudden cardiac death, or total mortality for high-dose citalopram and escitalopram differed significantly from that for comparable doses of fluoxetine, paroxetine, and sertraline. PMID:27736049
ERIC Educational Resources Information Center
Baldwin, Scott A.; Berkeljon, Arjan; Atkins, David C.; Olsen, Joseph A.; Nielsen, Stevan L.
2009-01-01
Most research on the dose-effect model of change has combined data across patients who vary in their total dose of treatment and has implicitly assumed that the rate of change during therapy is constant across doses. In contrast, the good-enough level model predicts that rate of change will be related to total dose of therapy. In this study, the…
NASA Technical Reports Server (NTRS)
Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; Label, Kenneth A.; Ladbury, Raymond L.; Mondy, Timothy K.; O'Bryan, Martha V.;
2017-01-01
Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.
Mazumder, Upal Kanti; Gupta, Malaya; Pal, Dilipkumar; Bhattacharya, Shiladitya
2003-01-01
Methanol extract of Cuscuta reflexa Roxb. stem (MECR) contain flavonoids (0.2%) and Corchorus olitorius Linn. seed (MECO) was found to contain steroids and cardenolide glycosides. Effects of multiple weekly dose of MECR (25, 50, 75 mg/kg, i.p.) and MECO (15, 20, 25 mg/kg, i.p.) on liver and kidney functions and hematological parameters in mice were studied. No significant alteration of RBC count and hemoglobin content was observed in all dose level of treatment in MECR and MECO treated mice whereas significant increase of clotting time was seen in moderate and high doses in both case. MECR and MECO both caused significant increase in WBC count only in high dose level of treatment. Both the extracts in medium and high dose level increased SGOT, SGPT, NPN and plasma cholesterol significantly. Serum alkaline phosphatase and total bilirubin were also increased by both moderate and high dose level of treatments in MECR and MECO treated mice respectively. Low dose of both the extract did not exhibit any significant change of creatinine and serum protein level. But high dose level of MECR and MECO significantly increased creatinine level. Increase in plasma cholesterol may be due to decrease in cholesterol catabolism owing to liver dysfunction of due to the intake of MECO itself as it was found to be steroid in nature. Elevated level of SGOT, SGPT and serum alkaline phosphatase activity in moderate and high dose level of weekly treated mice may be due to improper liver function following the treatment. Increased urea, non protein nitrogen and creatinine content in blood have been observed with impaired renal function. The slightly higher toxicity in case of MECO treated mice may be due to the presence of cardenolide glycosides in the ME of C. olitorius seed. However, low doses of MECR and MECO (25 and 15 mg/kg, i.p. respectively) did not exhibit any remarkable change on liver and kidney functions and hematological parameters.
Sugiyama, Takao; Sugimoto, Toyohiko; Suzuki, Sawako; Sato, Yuta; Tanaka, Tomoaki; Tatsuno, Ichiro
2015-08-01
Although high-dose glucocorticoids have been reported to cause new-onset diabetes mellitus (glucocorticoid-induced diabetes mellitus), its risk factors have remained to be determined. We investigated the risk factors related to glucocorticoid-induced diabetes mellitus diagnosed within 2 months after the high-dose treatment (newly treated with an initial high dose of > 20 mg prednisolone (PSL) equivalent per day for at least more than 6 months) in collagen vascular diseases. A total of 2,631 patients with collagen vascular diseases was registered between 1986 and 2006 in the Chiba-Shimoshizu Rheumatic Cohort. We analyzed 681 patients newly treated with high-dose glucocorticoid who did not have diabetes mellitus and/or its previous diagnosis (age: 46.3 ± 16.7 years, PSL dose: 40.0 ± 14.1 mg/day). Glucocorticoid-induced diabetes mellitus was diagnosed by two or more glucose measurements in patients with fasting glycaemia ≥ 7 mmol/L and 120 minutes post-load glycaemia ≥ 11.1 mmol/L. Glucocorticoid-induced diabetes mellitus was observed in 26.3% of patients, and the glucocorticoid-induced diabetes mellitus group had higher age, higher BMI, lower rates of females and systemic lupus erythematosus, higher rates of smoking, alcohol use, and microscopic polyangiitis. Multivariate logistic regression analysis demonstrated that the risk of glucocorticoid-induced diabetes mellitus was independently higher in every 10-year increment of initial age with adjusted odds ratio (OR) 1.556 (95% confidence interval: 1.359 - 1.783), in every 1 kg/m2 increment of BMI with OR 1.062 (1.002 - 1.124), in current smoking with OR 1.664 (1.057 - 2.622), and in every 10 mg increment of initial dose of prednisolone with OR 1.250 (1.074 - 1.454). High-dose glucocorticoids caused diabetes mellitus with high prevalence within a short period, and current smokers should be considered at higher risk of glucocorticoidinduced diabetes mellitus in addition to age, BMI, and initial dose.
Low-Dose Palliative Radiotherapy for Cutaneous B- and T-Cell Lymphomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neelis, Karen J.; Schimmel, Erik C.; Vermeer, Maarten H.
Purpose: To determine the efficacy of low-dose palliative radiotherapy for both low-grade malignant cutaneous B-cell lymphomas (CBCLs) and cutaneous T-cell lymphomas (mycosis fungoides). Methods and Materials: A total of 18 patients with low-grade CBCL (10 primary cutaneous marginal zone B-cell and 8 primary cutaneous follicle center lymphomas) with 44 symptomatic plaques and tumors underwent low-dose (4 Gy in two fractions) local radiotherapy. A total of 31 patients with mycosis fungoides were treated at 82 symptomatic sites, initially with 4 Gy and later with 8 Gy in two fractions. Results: The complete response rate for CBCL lesions was 72%. Of themore » 44 B-cell lymphoma lesions, 13 were re-treated to the same site after a median of 6.3 months because of persistent (n = 8) or recurrent (n = 5) symptomatic disease. Of the mycosis fungoides patients treated with 4 Gy in two fractions (17 lesions), 70% failed to respond. Increasing the dose to 8 Gy in two fractions yielded a complete response rate of 92% (60 of 65 lesions). The patients in whom low-dose radiotherapy failed were retreated with 20 Gy in eight fractions. Conclusion: Our results have demonstrated that low-dose involved-field radiotherapy induces a high response rate in both CBCL and cutaneous T-cell lymphoma lesions without any toxicity. Therefore, this treatment is now our standard palliative treatment. At progression, it is safe and feasible to apply greater radiation doses.« less
Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization
Sun, Lue; Mizuno, Yusuke; Iwamoto, Mari; Goto, Takahisa; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi
2014-01-01
Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose–area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. PMID:24968708
Kisielowski, C.; Frei, H.; Specht, P.; ...
2016-11-02
This article summarizes core aspects of beam-sample interactions in research that aims at exploiting the ability to detect single atoms at atomic resolution by mid-voltage transmission electron microscopy. Investigating the atomic structure of catalytic Co 3O 4 nanocrystals underscores how indispensable it is to rigorously control electron dose rates and total doses to understand native material properties on this scale. We apply in-line holography with variable dose rates to achieve this goal. Genuine object structures can be maintained if dose rates below ~100 e/Å 2s are used and the contrast required for detection of single atoms is generated by capturing largemore » image series. Threshold doses for the detection of single atoms are estimated. An increase of electron dose rates and total doses to common values for high resolution imaging of solids stimulates object excitations that restructure surfaces, interfaces, and defects and cause grain reorientation or growth. We observe a variety of previously unknown atom configurations in surface proximity of the Co 3O 4 spinel structure. These are hidden behind broadened diffraction patterns in reciprocal space but become visible in real space by solving the phase problem. Finallly, an exposure of the Co 3O 4 spinel structure to water vapor or other gases induces drastic structure alterations that can be captured in this manner.« less
Liao, T T; Deng, Q Y; Wu, B J; Li, S S; Li, X; Wu, J; Leng, Y X; Guo, Y B; Huang, N
2017-01-24
While a diamond-like carbon (DLC)-coated joint prosthesis represents the implant of choice for total hip replacement in patients, it also leads to concern due to the cytotoxicity of wear debris in the form of graphite nanoparticles (GNs), ultimately limiting its clinical use. In this study, the cytotoxicity of various GN doses was evaluated. Mouse macrophages and osteoblasts were incubated with GNs (<30 nm diameter), followed by evaluation of cytotoxicity by means of assessing inflammatory cytokines, results of alkaline phosphatase assays, and related signaling protein expression. Cytotoxicity evaluation showed that cell viability decreased in a dose-dependent manner (10-100 μg ml -1 ), and steeply declined at GNs concentrations greater than 30 μg ml -1 . Noticeable cytotoxicity was observed as the GN dose exceeded this threshold due to upregulated receptor of activator of nuclear factor kB-ligand expression and downregulated osteoprotegerin expression. Meanwhile, activated macrophage morphology was observed as a result of the intense inflammatory response caused by the high doses of GNs (>30 μg ml -1 ), as observed by the increased release of TNF-α and IL-6. The results suggest that GNs had a significant dose-dependent cytotoxicity in vitro, with a lethal dose of 30 μg ml -1 leading to dramatic increases in cytotoxicity. Our GN cytotoxicity evaluation indicates a safe level for wear debris-related arthropathy and could propel the clinical application of DLC-coated total hip prostheses.
Docea, Anca Oana; Gofita, Eliza; Goumenou, Marina; Calina, Daniela; Rogoveanu, Otilia; Varut, Marius; Olaru, Cristian; Kerasioti, Efthalia; Fountoucidou, Polyxeni; Taitzoglou, Ioannis; Zlatian, Ovidiu; Rakitskii, Valerii N; Hernandez, Antonio F; Kouretas, Dimitrios; Tsatsakis, Aristidis
2018-05-01
This study assessed the potential adverse health effects of long-term low-dose exposure to chemical mixtures simulating complex real-life human exposures. Four groups of Sprague Dawley rats were administered mixtures containing carbaryl, dimethoate, glyphosate, methomyl, methyl parathion, triadimefon, aspartame, sodium benzoate, calcium disodium ethylene diamine tetra-acetate, ethylparaben, butylparaben, bisphenol A, and acacia gum at doses of 0, 0.25, 1 or 5 times the respective Toxicological Reference Values (TRV): acceptable daily intake (ADI) or tolerable daily intake (TDI) in a 24 weeks toxicity study. Body weight gain, feed and water consumption were evaluated weekly. At 24 weeks blood was collected and biochemistry parameters and redox status markers were assessed. Adverse effects were observed on body weight gain and in hepatotoxic parameters such as the total bilirubin, alanine aminotransferase (ALT) and alkaline phosphatase (ALP), especially in low dose and affecting mainly male rats. The low dose group showed increased catalase activity both in females and males, whereas the high dose group exhibited decreased protein carbonyl and total antioxidant capacity (TAC) levels in both sex groups. Non-monotonic effects and adaptive responses on liver function tests and redox status, leading to non-linear dose-responses curves, are probably produced by modulation of different mechanisms. Copyright © 2018. Published by Elsevier Ltd.
Albero, R.; Cerdan, A.; Sanchez Franco, F.
1987-01-01
Hypothyroidism from iodide transport deficiency is a rare disease, especially when found in two affected siblings. Treatment with high doses of iodide has been recommended, but no long term results have been reported. Two siblings with congenital hypothyroidism due to total failure to transport iodide have been followed up during twelve and a half years of treatment with oral potassium iodide. Iodine doses varied between 10.3 and 22 mg/day, and serum total iodine concentrations between 100 and 210 micrograms/dl. Total triiodothyronine (T3), thyroxine (T4) and free T4 were in the normal range during the time of study. Basal thyroid stimulating hormones (TSH) and maximum TSH response to thyrotrophin releasing hormone (TRH) were also in the range of normal values. These data along with clinical findings confirmed the potential usefulness of iodine in hypothyroidism due to complete iodide transport defect. PMID:3451231
Cardell, Kristina; Akerlind, Britt; Sällberg, Matti; Frydén, Aril
2008-08-01
Hepatitis B vaccine has been shown to be highly efficient in preventing hepatitis B. However, 5%-10% of individuals fail to develop protective levels (>or=10 mIU/mL) of antibodies to hepatitis B surface antigen (anti-HBs) and are considered to be nonresponders. A total of 48 nonresponders and 20 subjects naive to the HBV vaccine received a double dose of combined hepatitis A and B vaccine (Twinrix) at 0, 1, and 6 months. The levels of anti-HBs and antibodies to hepatitis A virus (anti-HAV) were determined before vaccination and 1 month after each dose. Among 44 nonresponders, protective anti-HBs levels were found in 26 (59%) after the first dose and in 42 (95%) after the third dose. Among the control subjects, the corresponding figures were 10% and 100%, respectively. All subjects seroconverted to anti-HAV. The titers of both anti-HBs and anti-HAV were lower in the previously nonresponsive subjects (P< .01). Revaccination of nonresponders to the standard hepatitis B vaccine regimen with a double dose of the combined hepatitis A and B vaccine was highly effective. This is most likely explained by the increased dose, a positive bystander effect conferred by the hepatitis A vaccine, or both.
Liu, Yuanbao; Liu, Zhihao; Deng, Xiuying; Hu, Ying; Wang, Zhiguo; Lu, Peishan; Guo, Hongxiong; Sun, Xiang; Xu, Yan; Tang, Fenyang; Zhu, Feng-Cai
2018-05-01
In China, one dose measles-mumps-rubella vaccine (MMR) was administered to children aged 18-24 months. The mumps incidence was still high. Data on the waning immunity to mumps after MMR vaccination are limited. This study aimed to describe the waning immunity to mumps in kindergarten and primary school children to provide a scientific basis for confirming an optimal age for a second dose. An observational, prospective study on one-dose MMR in children in kindergarten and primary school was conducted from 2015 to 2016. Waning immunity to mumps in terms of seropositivity and geometric antibody concentration (GMC) with time was analyzed. In total, 7436 eligible subjects in kindergarten (3435) and primary school (4001) were included in 2015. The overall GMC (201.7 U/ml) and seropositivity (75.4%) to mumps antibodies in 2016 were significantly lower compared to those in 2015 (218.7 U/ml, 78.4%). Asymptomatic infection occurred within one year in 8.8% of children who received one-dose MMR. Children who received one-dose MMR in kindergarten and primary school were at high risk of mumps infection, and waning immunity occurred with time. Determining the optimal age for the second dose of MMR in children should be prioritized to prevent mumps epidemics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, Damodar, E-mail: dpokhrel@kumc.edu; Sood, Sumit; McClinton, Christopher
Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured onmore » T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.« less
Continuing evaluation of bipolar linear devices for total dose bias dependency and ELDRS effects
NASA Technical Reports Server (NTRS)
McClure, Steven S.; Gorelick, Jerry L.; Yui, Candice; Rax, Bernard G.; Wiedeman, Michael D.
2003-01-01
We present results of continuing efforts to evaluate total dose bias dependency and ELDRS effects in bipolar linear microcircuits. Several devices were evaluated, each exhibiting moderate to significant bias and/or dose rate dependency.
Andratschke, N; Alheid, H; Allgäuer, M; Becker, G; Blanck, O; Boda-Heggemann, J; Brunner, T; Duma, M; Gerum, S; Guckenberger, M; Hildebrandt, G; Klement, R J; Lewitzki, V; Ostheimer, C; Papachristofilou, A; Petersen, C; Schneider, T; Semrau, R; Wachter, S; Habermehl, D
2018-03-13
The intent of this pooled analysis as part of the German society for radiation oncology (DEGRO) stereotactic body radiotherapy (SBRT) initiative was to analyze the patterns of care of SBRT for liver oligometastases and to derive factors influencing treated metastases control and overall survival in a large patient cohort. From 17 German and Swiss centers, data on all patients treated for liver oligometastases with SBRT since its introduction in 1997 has been collected and entered into a centralized database. In addition to patient and tumor characteristics, data on immobilization, image guidance and motion management as well as dose prescription and fractionation has been gathered. Besides dose response and survival statistics, time trends of the aforementioned variables have been investigated. In total, 474 patients with 623 liver oligometastases (median 1 lesion/patient; range 1–4) have been collected from 1997 until 2015. Predominant histologies were colorectal cancer (n = 213 pts.; 300 lesions) and breast cancer (n = 57; 81 lesions). All centers employed an SBRT specific setup. Initially, stereotactic coordinates and CT simulation were used for treatment set-up (55%), but eventually were replaced by CBCT guidance (28%) or more recently robotic tracking (17%). High variance in fraction (fx) number (median 1 fx; range 1–13) and dose per fraction (median: 18.5 Gy; range 3–37.5 Gy) was observed, although median BED remained consistently high after an initial learning curve. Median follow-up time was 15 months; median overall survival after SBRT was 24 months. One- and 2-year treated metastases control rate of treated lesions was 77% and 64%; if maximum isocenter biological equivalent dose (BED) was greater than 150 Gy EQD2Gy, it increased to 83% and 70%, respectively. Besides radiation dose colorectal and breast histology and motion management methods were associated with improved treated metastases control. After an initial learning curve with regards to total cumulative doses, consistently high biologically effective doses have been employed translating into high local tumor control at 1 and 2 years. The true impact of histology and motion management method on treated metastases control deserve deeper analysis. Overall survival is mainly influenced by histology and metastatic tumor burden.
Novel oxytocin receptor variants in laboring women requiring high doses of oxytocin.
Reinl, Erin L; Goodwin, Zane A; Raghuraman, Nandini; Lee, Grace Y; Jo, Erin Y; Gezahegn, Beakal M; Pillai, Meghan K; Cahill, Alison G; de Guzman Strong, Cristina; England, Sarah K
2017-08-01
Although oxytocin commonly is used to augment or induce labor, it is difficult to predict its effectiveness because oxytocin dose requirements vary significantly among women. One possibility is that women requiring high or low doses of oxytocin have variations in the oxytocin receptor gene. To identify oxytocin receptor gene variants in laboring women with low and high oxytocin dosage requirements. Term, nulliparous women requiring oxytocin doses of ≤4 mU/min (low-dose-requiring, n = 83) or ≥20 mU/min (high-dose-requiring, n = 104) for labor augmentation or induction provided consent to a postpartum blood draw as a source of genomic DNA. Targeted-amplicon sequencing (coverage >30×) with MiSeq (Illumina) was performed to discover variants in the coding exons of the oxytocin receptor gene. Baseline relevant clinical history, outcomes, demographics, and oxytocin receptor gene sequence variants and their allele frequencies were compared between low-dose-requiring and high-dose-requiring women. The Scale-Invariant Feature Transform algorithm was used to predict the effect of variants on oxytocin receptor function. The Fisher exact or χ 2 tests were used for categorical variables, and Student t tests or Wilcoxon rank sum tests were used for continuous variables. A P value < .05 was considered statistically significant. The high-dose-requiring women had greater rates of obesity and diabetes and were more likely to have undergone labor induction and required prostaglandins. High-dose-requiring women were more likely to undergo cesarean delivery for first-stage arrest and less likely to undergo cesarean delivery for nonreassuring fetal status. Targeted sequencing of the oxytocin receptor gene in the total cohort (n = 187) revealed 30 distinct coding variants: 17 nonsynonymous, 11 synonymous, and 2 small structural variants. One novel variant (A243T) was found in both the low- and high-dose-requiring groups. Three novel variants (Y106H, A240_A249del, and P197delfs*206) resulting in an amino acid substitution, loss of 9 amino acids, and a frameshift stop mutation, respectively, were identified only in low-dose-requiring women. Nine nonsynonymous variants were unique to the high-dose-requiring group. These included 3 known variants (R151C, G221S, and W228C) and 6 novel variants (M133V, R150L, H173R, A248V, G253R, and I266V). Of these, R150L, R151C, and H173R were predicted by Scale-Invariant Feature Transform algorithm to damage oxytocin receptor function. There was no statistically significant association between the numbers of synonymous and nonsynonymous substitutions in the patient groups. Obesity, diabetes, and labor induction were associated with the requirement for high doses of oxytocin. We did not identify significant differences in the prevalence of oxytocin receptor variants between low-dose-requiring and high-dose-requiring women, but novel oxytocin receptor variants were enriched in the high-dose-requiring women. We also found 3 oxytocin receptor variants (2 novel, 1 known) that were predicted to damage oxytocin receptor function and would likely increase an individual's risk for requiring a high oxytocin dose. Further investigation of oxytocin receptor variants and their effects on protein function will inform precision medicine in pregnant women. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keehan, S; Taylor, M; Franich, R
2015-06-15
Purpose: To assess the risk posed by neutron induced activation of components in medical linear accelerators (linacs) following the delivery of high monitor unit 18 MV photon beams such as used in TBI. Methods: Gamma spectroscopy was used to identify radioisotopes produced in components of a Varian 21EX and an Elekta Synergy following delivery of photon beams. Dose and risk estimates for TBI were assessed using dose deliveries from an actual patient treatment. A 1 litre spherical ion chamber (PTW, Germany) has been used to measure the dose at the beam exit window and at the total body irradiation (TBI)more » treatment couch following large and small field beams with long beam-on times. Measurements were also made outside of the closed jaws to quantify the benefit of the attenuation provided by the jaws. Results: The radioisotopes produced in the linac head have been identified as {sup 187}W, {sup 56}Mn, {sup 24}Na and {sup 28}Al, which have half-lives from between 2.3 min to 24 hours. The dose at the beam exit window following an 18 MV 2197 MU TBI beam delivery was 12.6 µSv in ten minutes. The dose rate at the TBI treatment couch 4.8 m away is a factor of ten lower. For a typical TBI delivered in six fractions each consisting of four beams and an annual patient load of 24, the annual dose estimate for a staff member at the treatment couch for ten minutes is 750 µSv. This can be further reduced by a factor of about twelve if the jaws are closed before entering the room, resulting in a dose estimate of 65 µSv. Conclusion: The dose resulting from the activation products for a representative TBI workload at our clinic of 24 patients per year is 750 µSv, which can be further reduced to 65 µSv by closing the jaws.« less
Clinical trial of an inhibitor of RAGE-Aβ interactions in Alzheimer disease.
Galasko, Douglas; Bell, Joanne; Mancuso, Jessica Y; Kupiec, James W; Sabbagh, Marwan N; van Dyck, Christopher; Thomas, Ronald G; Aisen, Paul S
2014-04-29
To examine safety, tolerability, and efficacy of PF-04494700, an inhibitor of the receptor for advanced glycation end products (RAGE), in mild to moderate Alzheimer disease (AD). Double-blind, placebo-controlled trial at 40 academic centers (United States). Subjects with AD and Mini-Mental State Examination score 14-26 were randomized to PF-04494700 60 mg/day × 6 days, then 20 mg daily (high dose); 15 mg/day × 6 days, then 5 mg daily (low dose); or placebo, for 18 months. Clinical and laboratory measures were used to evaluate safety and tolerability. The primary efficacy measure was the Alzheimer's Disease Assessment Scale-cognitive (ADAS-cog). Secondary measures assessed clinical stage, function, behavior, MRI, and CSF biomarkers. A total of 399 subjects were randomized. In a prespecified interim analysis, when 50% of subjects had completed the 6-month visit, the high dose was associated with confusion, falls, and greater ADAS-cog decline and was discontinued. A second prespecified analysis compared low-dose and placebo groups for futility and safety approximately 12 months after all subjects were randomized. This analysis met criteria for futility, and treatment was discontinued. There were no safety concerns in the low-dose group. Analyses including post-futility data showed decreased decline on the ADAS-cog in the low-dose group at month 18. Other clinical and biomarker measures showed no differences between low-dose treatment and placebo. PF-04494700 at 20 mg/d was associated with increased adverse events and cognitive decline. At 5 mg/d, PF-04494700 had a good safety profile. A potential benefit for this low dose on the ADAS-cog is not conclusive, because of high dropout and discontinuation rates subsequent to the interim analyses. This study provides Class I evidence that in patients with AD high-dose PF-04494700 increased cognitive decline at 6 months and Class IV evidence that low-dose PF-04494700 slowed cognitive decline at 18 months.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yaparpalvi, R; Mynampati, D; Kuo, H
Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performedmore » using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm may very well be warranted.« less
Emilda, A S; Veri, Nora; Alchalidi, Alchalidi
2017-01-01
The purpose of this study was to investigate the effects of green tea (GT) on the spiral artery density and endometrial thickness in female rats treated with the depot-medroxyprogesterone acetate (DMPA). A total of 24 female rats were randomly divided into four groups (n = 6 each): The control group (no treatment), the DMPA-treated group, treated with DMPA and GT doses of 165 mg/kg of body weight/day, and treated with DMPA and GT doses of 330 mg/kg of body weight/day. Spiral artery density and endometrial thickness were subjected to histopathological analysis. Spiral artery density decreased in the DMPA-treated group, despite the insignificant difference ( P > 0.05). With regard to the administration of GT at doses of 165 and 330 mg/g of body weight/day, only GT at the high dose was capable of significantly preventing a decrease in spiral artery density ( P < 0.05). At this dose, the spiral arteries achieved a density comparable to that of the control group ( P > 0.05). Meanwhile, the administration of DMPA and/or DMPA with GT did not cause significant changes in endometrial thickness relative to the control group ( P > 0.05). DMPA induced a decrease in spiral artery density, despite the insignificant differences, and these changes could be normalized by the administration of high doses of GT. Therefore, GT could be a candidate herb to prevent the adverse effects of the contraceptive DMPA.
Renal dysfunction after total body irradiation: Dose-effect relationship
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kal, Henk B.; Kempen-Harteveld, M. Loes van
2006-07-15
Purpose: Late complications related to total body irradiation (TBI) as part of the conditioning regimen for hematopoietic stem cell transplantation have been increasingly noted. We reviewed and compared the results of treatments with various TBI regimens and tried to derive a dose-effect relationship for the endpoint of late renal dysfunction. The aim was to find the tolerance dose for the kidney when TBI is performed. Methods and Materials: A literature search was performed using PubMed for articles reporting late renal dysfunction. For intercomparison, the various TBI regimens were normalized using the linear-quadratic model, and biologically effective doses (BEDs) were calculated.more » Results: Eleven reports were found describing the frequency of renal dysfunction after TBI. The frequency of renal dysfunction as a function of the BED was obtained. For BED >16 Gy an increase in the frequency of dysfunction was observed. Conclusions: The tolerance BED for kidney tissue undergoing TBI is about 16 Gy. This BED can be realized with highly fractionated TBI (e.g., 6 x 1.7 Gy or 9 x 1.2 Gy at dose rates >5 cGy/min). To prevent late renal dysfunction, the TBI regimens with BED values >16 Gy (almost all found in published reports) should be applied with appropriate shielding of the kidneys.« less
Imaging characteristics of different mammographic screens.
Kuhn, H; Knüpfer, W
1992-01-01
A study of mammography systems with green-emitting screens was conducted to determine how the image quality parameters (apart from dose requirement), such as modulation transfer function (MTF) and Wiener spectrum (WS), depend on the dye content of the compound and coating weight of the screen. In addition, the contribution to total noise of the individual components, i.e., film, screen, and quantum noise, was studied. The quantities derived from MTF and WS, namely detective quantum efficiency (DQE) and noise equivalent quanta (NEQ), were also investigated in regard to their dose dependency. It can be demonstrated that the MTF of the screens becomes more favorable when the dye content is increased, while noise is not significantly affected. This suggests the use of a mammography screen capable of greater detail recognition, requiring at least double the dose of today's conventional systems with approximately 80 microGy system dose. On the other hand, the manufacture of a screen with about 60% of the dose of the conventional system is possible with very little loss in image quality. For the systems in common use today (80 microGy), quantum noise represents a considerable share of the total noise at low spatial frequencies, whereas in high spatial frequencies, the graininess of the film dominates quantum noise and screen structure.
The degree and nature of radiation damage in zircon observed by 29Si nuclear magnetic resonance
NASA Astrophysics Data System (ADS)
Farnan, I.; Salje, E. K. H.
2001-02-01
A quantitative analysis of 29Si nuclear magnetic resonance spectra of radiation damaged, natural zircons showed that the local structure in crystalline and amorphous regions depend explicitly on radiation dose. Nonpercolating amorphous islands of high density "glass" within the crystalline matrix show a low interconnectivity of SiO4 tetrahedra. This structural state is quite different from that of the high dose, percolating regions of low density glass with more polymerised tetrahedra. A continuous nonlinear dose dependence between the high and low density glass states is reported. A continuous evolution of the local structure of the crystalline phase up to the percolation point is also reported. No phase separation into binary oxides was observed. The total number of permanently displaced atoms per α-recoil event is ˜3800 atoms for low radiation doses and decreases to ˜2000 atoms for 10×1018 α events/g. No indication of partitioning of paramagnetic impurities between crystalline and amorphous regions was found for these natural zircons. The amorphous fractions of the metamict zircons were determined as a function of their accumulated radiation dose. These values coincide closely with those recently determined by x-ray diffraction studies. They are much greater than previously assumed based on density measurements. The dose dependence is consistent with the concept of direct impact amorphization in the atomic cascade following an α-recoil event.
Lagator, Mato; Vogwill, Tom; Mead, Andrew; Colegrave, Nick; Neve, Paul
2013-05-01
The widespread evolution of resistance to herbicides is a pressing issue in global agriculture. Evolutionary principles and practices are key to the management of this threat to global food security. The application of mixtures of herbicides has been advocated as an anti-resistance strategy, without substantial empirical support for its validation. We evolved experimentally populations of the unicellular green chlorophyte, Chlamydomonas reinhardtii, to minimum inhibitory concentrations (MICs) of single-herbicide modes of action and to pair-wise and three-way mixtures between different herbicides at various total combined doses. Herbicide mixtures were most effective when each component was applied at or close to its MIC. When doses were high, increasing the number of mixture components was also effective in reducing the evolution of resistance. Employing mixtures at low combined doses did not retard resistance evolution, even accelerating the evolution of resistance to some components. At low doses, increasing the number of herbicides in the mixture tended to select for more generalist resistance (cross-resistance). Our results reinforce findings from the antibiotic resistance literature and confirm that herbicide mixtures can be very effective for resistance management, but that mixtures should only be employed where the economic and environmental context permits the applications of high combined doses. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.
2015-10-01
HGF and/or various treatment doses of cabozantinib ( Cabo ) in MET high/AR-negative prostate cancer cells for 24 hours. Subtask 4: Assess whether c...multityrosine kinase inhibitor cabozantinib ( Cabo ) as indicated. Left panel is representative pictures of indicated treatment results by fluorescent...phospho-MET and total MET protein levels. (C) Invasion assays were performed in the presence of HGF and/or various treatment doses of cabozantinib ( Cabo
ERIC Educational Resources Information Center
Bakheit, Abdel Magid O.; Liptrot, Anthea; Newton, Rachel; Pickett, Andrew M.
2012-01-01
A large cumulative dose of botulinum toxin type A (BoNT-A), frequent injections, a short interval between treatment cycles, and a long duration of treatment have all been suggested, but not confirmed, to be associated with a high incidence of neutralizing antibodies to the neurotoxin. The aim of this study was to investigate whether these…
Vila-Nova, Camila; Wehby, George L; Queirós, Fernanda C; Chakraborty, Hrishkesh; Félix, Temis M; Goco, Norman; Moore, Janet; Gewehr, Eduardo V; Lins, Lorene; Affonso, Carla M C; Murray, Jeffrey C
2013-07-01
We report on the risk of miscarriage with high- and low-dosage periconceptional folic acid (FA) supplementation from a double-blind randomized clinical trial for prevention of orofacial cleft recurrence in Brazil. Women at risk of recurrence of orofacial clefts in their offspring were randomized into high (4 mg/day) and low (0.4 mg/day) doses of FA supplementation. The women received the study pills before pregnancy, and supplementation continued throughout the first trimester. Miscarriage rates were compared between the two FA groups and with the population rate. A total of 268 pregnancies completed the study protocol, with 141 in the 4.0-mg group and 127 in the 0.4-mg group. The miscarriage rate was 14.2% in the low-dose FA group (0.4 mg/day) and 11.3% for the high-dose group (4 mg/day) (P=0.4877). These miscarriage rates are not significantly different from the miscarriage rate in the Brazilian population, estimated to be around 14% (P=0.311). These results indicate that high-dose FA does not increase miscarriage risk in this population and add further information to the literature on the safety of high FA supplementation for prevention of birth defect recurrence.
Mazonakis, Michalis; Berris, Theoharris; Lyraraki, Efrossyni; Damilakis, John
2013-10-01
Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis. Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients. For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4-146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10(-5) to 837.4 × 10(-5) depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2-541.0) × 10(-5). The probability of bladder cancer development was more than 113.7 × 10(-5) and 110.3 × 10(-5) for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003-68.5) × 10(-5). The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ site in respect to treatment volume and patient's gender and age. The presented risk estimates may be useful in the follow-up studies of irradiated patients.
Efficacy of short-term moderate or high-dose rosuvastatin in preventing contrast-induced nephropathy
Liang, Min; Yang, Shicheng; Fu, Naikuan
2017-01-01
Abstract Background: The prophylactic efficacy of statin pretreatment for the prevention of contrast-induced nephropathy (CIN) in patients undergoing coronary angiography (CAG) or percutaneous coronary intervention (PCI) remains controversial. The aim of the study was to perform a meta-analysis of randomized controlled trials (RCTs) to assess the effectiveness of short-term moderate or high-dose rosuvastatin pretreatment in preventing CIN. Methods: We included RCTs comparing short-term moderate or high-dose rosuvastatin treatment versus low-dose rosuvastatin treatment or placebo for preventing CIN. The primary endpoint was the incidence of CIN within 2 to 5 days after contrast administration, and related-parameters including serum creatinine (SCr), cystatin C (CysC), hypersensitive C-reactive protein (hs-CRP), urine microalbumin (mALB) were also extracted. Results: Fifteen RCTs with a total of 2673 patients were identified and analyzed. Patients who received moderate or high-dose rosuvastatin pretreatment had a 55% lower risk of CIN compared with low-dose rosuvastatin pretreatment or placebo group based on a fixed effect model (RR = 0.45, 95% CI 0.35–0.58, P < .0001). The benefit of moderate or high-dose rosuvastatin was consistent in both comparisons with low-dose rosuvastatin (RR = 0.40, 95% CI 0.27–0.59, P < .0001) or placebo (RR = 0.45, 95% CI 0.35–0.58, P < .0001). And moderate (20 mg) or high dose (≥40 mg) rosuvastatin significantly reduced the incidence of CIN compared with the control (RR = 0.39, 95% CI 0.29–0.54, P < .0001, RR = 0.56, 95% CI 0.37–0.85, P = .006, respectively). Subgroup analysis showed that moderate or high-dose rosuvastatin pretreatment could decrease the incidence of CIN in patients with chronic kidney disease (CKD) (RR = 0.53, 95% CI 0.30–0.93, P = .03) or diabetes mellitus (DM) (RR = 0.51, 95% CI 0.31–0.86, P = .01) or acute coronary syndrome (ACS) patients undergoing PCI (RR = 0.52, 95% CI 0.35–0.76, P = .0009) or in studies which received mean contrast volume ≥110 mL (RR = 0.43, 95% CI 0.32–0.58, P < .0001). The SCr, CysC, hs-CRP, and mALB after the operation in the moderate or high-dose rosuvastatin group were lower than those of low-dose rosuvastatin group. Conclusion: This meta-analysis demonstrated that moderate or high-dose rosuvastatin treatment could reduce the incidence of CIN in patients undergoing CAG or PCI. Moreover, moderate or high-dose rosuvastatin would be beneficial in high-risk patients with CKD or DM or undergoing PCI. PMID:28682890
Effects of dietary methylmercury on juvenile Sacramento blackfish bioenergetics.
Houck, Ann; Cech, Joseph J
2004-08-10
Although much is known about the biogeochemical cycling of mercury in the environment, relatively little is known about methylmercury (MeHg) bioaccumulation in fishes and how chronic sub-lethal exposures affect their functioning. Several species of fish in Clear Lake, California have high MeHg tissue levels, including Sacramento blackfish, Orthodon microlepidotus, a large native cyprinid that is fished commercially. We fed juvenile blackfish one of four diets containing MeHg (0.21 mg/kg control; 0.52 mg/kg low; 22.2 mg/kg medium; and 55.5 mg/kg high treatments) for 70 days. There were no statistical differences (P > 0.05) in food consumption among the treatment groups. By 35 days the high treatment group had a significantly depressed growth rate when compared to the control group (P < 0.05) and by 70 days both the medium and the high groups had significantly lower growth rates (P < 0.05). The high-dose group had a significantly (P < 0.05) lower specific growth rate (SGR) compared all other treatment groups at 35 days, although by 70 days these differences were not significant. The wet/dry muscle mass and muscle mass/total mass ratios, condition factor, and resting routine metabolic rates at both 35 and 70 days were statistically indistinguishable (P > 0.05) between treatment groups. All treatment groups assimilated the dietary MeHg into muscle tissue in a dose-dependent fashion. Percent assimilation was significantly lower (P < 0.05) in the high-dose group compared to the low-dose group at 35 days, (control 53%, low-dose 61%, medium-dose 50%, and high-dose 40%) but at 70 days assimilation was lower (35, 43, 42, and 32%, respectively) and statistically indistinguishable (P > 0.05) among the treatment groups. Dietary MeHg concentrations and bioaccumulation rates were correlated (r2 = 0.98 at 35 days, 0.99 at 70 days). These results may contribute to construction of ecosystem mercury models and more informed natural resources management at Clear Lake.
Fung, Mitchell; Bowsher, John G; Van Citters, Douglas W
2018-06-01
Ultra-high molecular weight polyethylene (UHMWPE) is the current gold standard for bearing materials used in total joint arthroplasty. High-dose radiation is commonly used to crosslink UHMWPE, thereby improving its wear resistance. A subsequent remelting step eliminates trapped residual free radicals to promote oxidative stability on the shelf, and to prevent material degradation over the long term. Assessment of clinically retrieved, highly crosslinked UHMWPE devices shows signs of unanticipated oxidation occurring in vivo, despite the absence of free radicals prior to implantation. These findings warrant further investigation into possible factors impacting this phenomenon along with its clinical implications. The overall objective of this work is to quantify the influence of irradiation dose and source on UHMWPE's oxidative stability, along with the effects of oxidation on the ultimate mechanical properties, including strength, ductility, and toughness. The results showed a strong positive correlation between maximum oxidation and initial transvinylene content. Critical oxidation levels in the context of mechanical property loss were determined for e-beam and gamma treatments at various radiation doses. Further, it was shown that critical oxidation was more dependent on radiation dose and less dependent on source. If in vivo oxidation persists in these devices, this can potentially lead to mechanical failure (e.g. fatigue damage) as observed in terminally gamma-sterilized devices. Copyright © 2018 Elsevier Ltd. All rights reserved.
Yuqi, Luo; Chengtang, Wu; Ying, Wen; Shangtong, Lei; Kangxiong, Liao
2008-09-01
The purpose was to investigate the expression of musashi-1 (msi-1) and its significances in small intestinal mucosa that was severely damaged by high-dose 5-FU. A total of 40 adult C57BL/6J mice were divided into two groups: the control group (n = 8, group A) and experimental group (n = 32). The mice in the control group were treated with PBS by intraperitoneal injection, and the other mice were treated with high-dose 5-FU (150 mg/kg body weight for 5 consecutive days) by intraperitoneal injection. At the 1st (group B), 3rd (group C) and 5th (group D) day after treatment with high-dose 5-FU, the dying mice were killed, HE staining and immunohistochemical techniques were used to detect the expression of the putative marker of intestinal epithelial stem cells, msi-1, in samples of the middle intestine from these mice, and the percentage of the msi-1-positive cells from the intestinal mucosal cells of the mice in group B was detected by FACS. After treatment with high-dose 5-FU, the intestinal mucosa suffered severe damage: the villi and crypts disappeared, the number of msi-1-positive cells increased greatly, the intestinal epithelial cells could be divided into two fractions by FACS, and the percentage of msi-1-positive cells was up to 67.75% in the fraction in which the value of FSC was higher. After treatment with high-dose 5-FU, the percentage of intestinal stem cells had increased significantly, which was useful for the further isolation and enrichment of intestinal epithelial stem cells.
Schmittner, M D; Faulhaber, J; Kemler, B; Koenen, W; Thumfart, J O; Weiss, C; Neumaier, M; Beck, G C
2010-12-01
Tumescent local anaesthesia (TLA) with high prilocaine doses leads to formation of methemoglobin (MHb) which is known to be a potent activator of pro-inflammatory endothelial cell response in vitro. As TLA is widely used for large dermatological resections, the aim of this study was to investigate the effects of high prilocaine doses on the systemic inflammatory response in vivo and its clinical relevance. This prospective study examines the influence of MHb on serum interleukin (IL)-6, IL-8 and tumour necrosis tumour necrosis (TNF)-α levels up to 72 h after application of TLA with prilocaine in doses higher than 600 mg. A total of 30 patients received prilocaine in a median dose of 1500 mg (range: 880-4160 mg) for large resections. Peak prilocaine serum concentration was reached 4 h (0.72 ± 0.07 μg/mL), the maximum concentration of MHb (7.43 ± 0.87%) and IL-6 (28.4 ± 4.1 U/L) 12 h after TLA application. TNF-α and IL-8 release were not found significantly increased. Three patients developed MHb concentrations >15%. This clinical study shows for the first time that a high prilocaine serum concentration leads in vivo to elevated systemic levels of IL-6 but not of IL-8 and TNF-α because of initial high MHb levels. Because of possible and unpredictable high MHb concentrations, TLA should only be performed with prilocaine in doses of 2.5 mg/kg. In general, new solutions of TLA are necessary to achieve adequate anaesthesia for large dermatological resections to decrease the risk of methemoglobinaemia. © 2010 The Authors. Journal compilation © 2010 European Academy of Dermatology and Venereology.
Yun, K L; Fann, J I; Sokoloff, M H; Fong, L G; Sarris, G E; Billingham, M E; Miller, D C
1991-01-01
With the advent of cyclosporin A, accelerated coronary arteriosclerosis has become the major impediment to the long-term survival of heart transplant recipients. Due to epidemiologic reports suggesting a salutary effect of fish oil, the dose response of fish oil on graft coronary arteriosclerosis in a rabbit heterotopic cardiac allograft model was assessed using safflower oil as a caloric control. Seven groups of New Zealand White rabbits (n = 10/group) received heterotropic heart transplants from Dutch-Belted donors and were immunosuppressed with low-dose cyclosporin A (7.5 mg/kg/day). Group 1 animals were fed a normal diet and served as control. Group 2, 3, and 4 animals received a daily supplement of low- (0.25 mL/kg/day), medium- (0.75 mL/kg/day), and high- (1.5 mL/kg/day) dose fish oil (116 mg n-3 polyunsaturated fatty acid/mL), respectively. Group 5, 6, and 7 animals were supplemented with equivalent dose of safflower oil (i.e., 0.25, 0.75, and 1.5 mL/kg/day). Oil-supplemented rabbits were pretreated for 3 weeks before transplantation and maintained on the same diet for 6 weeks after operation. The extent of graft coronary arteriosclerosis was quantified using computer-assisted, morphometric planimetry. When the animals were killed, cyclosporin A was associated with elevated plasma total cholesterol and triglyceride levels in the control group. While safflower oil prevented the increase in plasma lipids at all dosages, fish oil ameliorated the cyclosporin-induced increase in total cholesterol only with high doses. Compared to control animals, there was a trend for more graft vessel disease with increasing fish oil dose, as assessed by mean luminal occlusion and intimal thickness. A steeper trend was observed for increasing doses of safflower oil; compared to the high-dose safflower oil group, animals supplemented with low-dose safflower oil had less mean luminal occlusion (16.3% +/- 5.9% versus 41.4% +/- 7.6%, p less than 0.017) and intimal thickness (7.9 +/- 1.9 microns versus 34.0 +/- 13.0 microns, analysis of variance: p = 0.054). Low-dose safflower oil also had a slight, but nonsignificant, beneficial effect on graft vessel disease when compared to control rabbits. The same trends were observed in the degree of histologic rejection (0 = none to 3 = severe) in fish oil- and safflower oil-treated animals. Rejection score correlated weakly but significantly (p = 0.0001) with mean luminal occlusion (r = 0.52) and intimal thickness (r = 0.46). Therefore allograft coronary disease in this model appeared to exhibit an unfavorable, direct-dose response to fish oil and safflower oil, independent of effects on plasma lipids.(ABSTRACT TRUNCATED AT 400 WORDS) Images Fig. 2. PMID:1867523
Wang, Qinghu; Jin, Jinmei; Dai, Nayintai; Han, Narenchaoketu; Han, Jingjing; Bao, Baiyinmuqier
2016-04-01
The aerial parts of Artemisia frigida Willd. are used to treat joint swelling, renal heat, abnormal menstruation, and sore carbuncle. The anti-inflammatory effects of A. frigida have been well-known in folk medicine, suggesting that components extracted from A. frigida could potentially treat inflammatory disease. With the aim of discovering bioactive compounds, in this study, we extracted total flavonoids from the aerial parts of A. frigida and investigated their anti-inflammatory effects against inflammation induced by carrageenan and egg albumin in rats. At the doses studied, total flavonoids (100 mg/kg, 200 mg/kg, and 400 mg/kg) and some isolated compounds (30 mg/kg) showed significant and dose-dependent anti-inflammatory effects. According to the high-performance liquid chromatography analysis of the total flavonoids from A. frigida, there are five major compounds, namely, 5-hydroxy-3',4'-dimethoxy-7-O-β-d-glucuronide (F1), 5-hydroxy-3',4',5'-trimethoxy-7-O-β-d-glucuronide (F2), 5,7,3'-trihydroxy-6,4'-dimethoxyflavone (F3), 5,3'-dihydroxy-6,7,4'-trimethoxyflavone (F4), and 5,3'-dihydroxy-3,6,7,4'-tetramethoxyflavone (F5), which may explain the anti-inflammatory activity. Copyright © 2016. Published by Elsevier B.V.
Liyanage, Gayani C; Lekamwasam, Sarath; Weerarathna, Thilak P; Liyanage, Chandrani E
2017-12-01
Aim of this study was to determine the effect of high dose vitamin D given to patients with early diabetic renal disease on systolic and diastolic blood pressure, total cholesterol (TC), low-density lipoproteins (LDL), triglycerides (TG) and high density lipoproteins (HDL) in a randomized controlled trial MATERIALS AND METHOD: Patients with early diabetic nephropathy were recruited. Selected patients were allocated to two groups by Block randomization method. Treatment group received 50,000 IU of vitamin D3 intramuscularly and the control group was given an equal volume of distilled water (0.25mL) monthly for six months. Blood and urine were collected at the baseline for biochemical analyses and blood pressure was measured. After six months all the measurements done at the baseline were repeated. Of 155 patients invited, 85 were randomly assigned to two groups. No significant differences were found between treatment and control groups at the baseline. Vitamin D therapy significantly reduced DBP, total cholesterol and LDL but the between group differences were not significant. There was an increase in HDL cholesterol level in the treatment group while there was no change in the control group Between groups difference was significant (P=<0.001). There was a significant improvement of serum HDL level with six months therapy of high dose vitamin D in patients with early diabetic nephropathy. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Cho, Oyeon; Chun, Mison; Oh, Young-Taek; Noh, O Kyu; Chang, Suk-Joon; Ryu, Hee-Sug; Lee, Eun Ju
2017-10-01
Radioresistance often leads to poor survival in concurrent chemoradiotherapy-treated cervical squamous cell carcinoma, and reliable biomarkers can improve prognosis. We compared the prognostic potential of hemoglobin, absolute neutrophil count, and absolute lymphocyte count with that of squamous cell carcinoma antigen in concurrent chemoradiotherapy-treated squamous cell carcinoma. We analyzed 152 patients with concurrent chemoradiotherapy and high-dose-rate intracavitary brachytherapy-treated cervical squamous cell carcinoma. Hemoglobin, absolute neutrophil count, absolute lymphocyte count, and squamous cell carcinoma antigen were quantitated and correlated with survival, using Cox regression, receiver operating characteristic curve analysis, and Kaplan-Meier plots. Both hemoglobin and absolute lymphocyte count in the second week of concurrent chemoradiotherapy (Hb2 and ALC2) and squamous cell carcinoma antigen in the third week of concurrent chemoradiotherapy (mid-squamous cell carcinoma antigen) correlated significantly with disease-specific survival and progression-free survival. The ratio of high-dose-rate intracavitary brachytherapy dose to total dose (high-dose-rate intracavitary brachytherapy ratio) correlated significantly with progression-free survival. Patients with both low Hb2 (≤11 g/dL) and ALC2 (≤639 cells/µL) showed a lower 5-year disease-specific survival rate than those with high Hb2 and/or ALC2, regardless of mid-squamous cell carcinoma antigen (mid-squamous cell carcinoma antigen: ≤4.7 ng/mL; 5-year disease-specific survival rate: 85.5% vs 94.6%, p = 0.0096, and mid-squamous cell carcinoma antigen: >4.7 ng/mL; 5-year disease-specific survival rate: 43.8% vs 66.7%, p = 0.192). When both Hb2 and ALC2 were low, the low high-dose-rate intracavitary brachytherapy ratio (≤0.43) subgroup displayed significantly lower 5-year disease-specific survival rate compared to the subgroup high high-dose-rate intracavitary brachytherapy ratio (>0.43) (62.5% vs 88.2%, p = 0.0067). Patients with both anemia and lymphopenia during concurrent chemoradiotherapy showed poor survival, independent of mid-squamous cell carcinoma antigen, and escalating high-dose-rate intracavitary brachytherapy ratio might improve survival.
Total-dose radiation effects data for semiconductor devices: 1985 supplement, volume 1
NASA Technical Reports Server (NTRS)
Martin, K. E.; Gauthier, M. K.; Coss, J. R.; Dantas, A. R. V.; Price, W. E.
1985-01-01
Steady-state, total-dose radiation test data are provided, in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 provides total-dose radiation test data on integrated circuits. Volume 1 of this 1985 Supplement contains new total-dose radiation test data generated since the August 1, 1981 release date of the original Volume 1. Publication of Volume 2 of the 1985 Supplement will follow that of Volume 1 by approximately three months.
Anagnostopoulos, G; Baltas, D; Geretschlaeger, A; Martin, T; Papagiannis, P; Tselis, N; Zamboglou, N
2003-11-15
To evaluate the potential of in vivo thermoluminescence dosimetry to estimate the accuracy of dose delivery in conformal high-dose-rate brachytherapy of prostate cancer. A total of 50 LiF, TLD-100 cylindrical rods were calibrated in the dose range of interest and used as a batch for all fractions. Fourteen dosimeters for every treatment fraction were loaded in a plastic 4F catheter that was fixed in either one of the 6F needles implanted for treatment purposes or in an extra needle implanted after consulting with the patient. The 6F needles were placed either close to the urethra or in the vicinity of the median posterior wall of the prostate. Initial results are presented for 18 treatment fractions in 5 patients and compared to corresponding data calculated using the commercial treatment planning system used for the planning of the treatments based on CT images acquired postimplantation. The maximum observed mean difference between planned and delivered dose within a single treatment fraction was 8.57% +/- 2.61% (root mean square [RMS] errors from 4.03% to 9.73%). Corresponding values obtained after averaging results over all fractions of a patient were 6.88% +/- 4.93% (RMS errors from 4.82% to 7.32%). Experimental results of each fraction corresponding to the same patient point were found to agree within experimental uncertainties. Experimental results indicate that the proposed method is feasible for dose verification purposes and suggest that dose delivery in transperineal high-dose-rate brachytherapy after CT-based planning can be of acceptable accuracy.
Reinisch, Walter; Altorjay, Istvan; Zsigmond, Ferenc; Primas, Christian; Vogelsang, Harald; Novacek, Gottfried; Reinisch, Sieglinde; Thomsen, Lars L
2015-01-01
Iron isomaltoside 1000 (Monofer®) is a high-dose intravenous (IV) iron, which in a recent 8 weeks trial in inflammatory bowel disease (IBD) subjects with iron deficiency anemia (IDA) demonstrated good tolerability and efficacy. The present trial is an extension to this trial, which evaluates the need for additional high IV iron doses to maintain a stable hemoglobin (Hb) ≥12.0 g/dl. This was a prospective, open-label, 12 months trial of European IBD subjects willing to participate after completing the lead-in trial. Subjects were allowed re-dosing with 500-2000 mg single doses of iron isomaltoside 1000 infused over ∼15 min at 3 months intervals depending on a predefined algorithm. Outcome measures included Hb, safety parameters and need for additional iron dosing. A total of 39 subjects were enrolled of which 34 subjects required re-dosing with a median cumulative 1-year dose of 1.8 g (mean cumulative dose 2.2 g). The mean (SD) Hb was 12.3 (1.5) g/dl at baseline, 12.8 (1.6) g/dl at 3 months, 12.8 (1.6) g/dl at 6 months, 12.9 (1.4) g/dl at 9 months and 12.9 (1.6) g/dl at 12 months. Seventy-four percent of subjects who had an Hb ≥12.0 g/dl at baseline were able to maintain Hb ≥12.0 g/dl till the end of the trial at 12 months. Nonserious probably related hypersensitivity reactions without significant hypotension were reported at the beginning of the infusion in two subjects, who recovered without sequelae. Repeated treatment of iron deficiency with iron isomaltoside 1000 could avoid episodes of IDA without major safety issues.
Ma, Hai-ying; Chen, Jin-yao; Zhang, Li-shi
2011-11-01
To study the protective effects of Tianji soft capsule (TJSC) on blood lipids, internal antioxidant system and vascular endothelial system in hyperlipidemia rats. Seventy two healthy male rats were divided into six groups. The rats in control group were administered with ordinary diet. The rats in model group were fed with high cholesterol/lipid diet to induce hyperlipidemia. The rats in TJSC and CoQ10 groups were fed with high cholesterol/lipid diet, and treated with TJSC at different doses of 83 (low-dose group, L), 250 (middle-dose group, M), 750 (high-dose group, H) mg/kg, and CoQ10 at the dose of 83 mg/kg, respectively. All animals were put to death after four weeks, effects on lipid level; antioxidant system and endothelial system were evaluated through detection of total cholesterol (TC), triglyceride (TG), very low density lipoprotein (VLDL), atherogenic index (AI), malondidehyde (MDA) and plasma endothelin (ET), HDL/TC ratio, activities of superoxide dismutase (SOD) and nitric oxide (NO). Compared with model group, serum TC, TG, VLDL, AI, MDA and ET reduced and the HDL/TC ratio increased, meanwhile activities of SOD and NO were enhanced. TJSC can regulate the lipid metabolism, enhance antioxidant system and protect the vascular endothelia system in hyperlipiemic rats.
Assessment of ²¹⁰Po in Italian diet.
Meli, Maria Assunta; Desideri, Donatella; Roselli, Carla; Feduzi, Laura
2014-07-15
This research was dedicated to the study, in the Italian daily diet, of the background activity concentration of (210)Po, a radionuclide with a high radiotoxicity. (210)Po was determined by alpha spectrometry. For food products of vegetable origin, the (210)Po activity concentration follows the trend: leafy vegetable>flour>rice>fruits>pasta>other vegetables>fruit vegetable; for those of animal origin: eggs>cheese>milk. The (210)Po activity concentration was also compared with that found by the same authors in meat, sea food, water and beverages in a previous study. The committed effective doses to individuals of three population groups (infants, children and adults) were 379, 222 and 151 μSv y(-1), respectively. The intake of foods of marine origin contributed about 67% of the total dose due to (210)Po ingestion. The effective dose, from (210)Po ingested by total diet, accounts for only 5-12% of the natural radiation exposure in Italy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Park, Bradley J; Palace, Vince; Wautier, Kerry; Gemmill, Bonnie; Tomy, Gregg
2011-09-15
Tetrabromoethylcyclohexane (TBECH) is an additive brominated flame retardant used in domestic and industrial applications. It has been detected in wildlife, and there is early evidence that it is an endocrine disruptor. Whereas other brominated flame retardants with similar physicochemical properties have been shown to disrupt the thyroid axis, no such evaluation has been conducted for TBECH. To elucidate this, juvenile brown trout (Salmo trutta) were fed either a control diet or diets containing low, medium, or high doses of β-TBECH, the isomer most frequently detected in wildlife, for 56 days (uptake phase) followed by a control diet for an additional 77 days (depuration phase). Eight fish per treatment were lethally sampled on uptake days 7, 14, 21, 35, 49, and 56 and on depuration days 7, 21, 35, 49, and 77 to assess fish condition, circulating free and total triiodothyronine and thyroxine, and thyroid epithelial cell height. Although there was no effect on condition factor, there was a significant reduction in total plasma thyroxine in the high dose group and a significant increase in mean thyroid epithelial cell height in the low, medium, and high dose groups during the uptake phase, whereas there were no differences in the depuration phase. These results indicate that β-TBECH may modulate the thyroid axis in fish at environmentally relevant concentrations.
Faure, Marguerite E; Swart, Laurens E; Dijkshoorn, Marcel L; Bekkers, Jos A; van Straten, Marcel; Nieman, Koen; Parizel, Paul M; Krestin, Gabriel P; Budde, Ricardo P J
2018-05-01
Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiu, J; Braunstein, S; McDermott, M
Purpose: Sharp dose fall-off is the hallmark of brain radiosurgery to deliver a high dose of radiation to the target while minimizing dose to normal brain tissue. In this study, we developed a technique for the purpose of enhancing the peripheral dose gradient by magnifying the total number of beams focused toward each isocenter via patient head tilt and simultaneous beam intensity modulations. Methods: Computer scripting for the proposed beam number enhancement (BNE) technique was developed. The technique was tested and then implemented on a clinical treatment planning system for a dedicated brain radiosurgical system (GK Perfexion, Elekta Oncology). Tomore » study technical feasibility and dosimetric advantages of the technique, we compared treatment planning quality and delivery efficiency for 20 radiosurgical cases previously treated at our institution. These cases included relatively complex treatments such as acoustic schwannoma, meningioma, brain metastasis and mesial temporal lobe epilepsy. Results: The BNE treatment plans were found to produce nearly identical target volume coverage (absolute value < 0.5%, P > 0.2) and dose conformity (BNE CI= 1.41±0.15 versus 1.41±0.20, P>0.9) as the original treatment plans. The total beam-on time for theBNE treatment plans were comparable (within 1.0 min or 1.8%) with those of the original treatment plans for all the cases. However, BNE treatment plans significantly improved the mean gradient index (BNE GI = 2.9±0.3 versus original GI =3.0±0.3 p<0.0001) and low-level isodose volumes, e.g. 20-50% prescribed isodose volumes, by 2.0% to 5.0% (p<0.02). Furthermore, with 4 to 5-fold increase in the total number of beams, the GI decreased by as much as 20% or 0.5 in absolute values. Conclusion: BNE via head tilt and simultaneous beam intensity modulation is an effective and efficient technique that physically sharpens the peripheral dose gradient for brain radiosurgery.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopp, Robert W.; Duff, Michael, E-mail: mduff@cancercarewny.com; Catalfamo, Frank
2011-01-01
We compared normal tissue radiation dose for the treatment of prostate cancer using 2 different radiation therapy delivery methods: volumetric modulated arc therapy (VMAT) vs. fixed-field intensity-modulated radiation therapy (IMRT). Radiotherapy plans for 292 prostate cancer patients treated with VMAT to a total dose of 7740 cGy were analyzed retrospectively. Fixed-angle, 7-field IMRT plans were created using the same computed tomography datasets and contours. Radiation doses to the planning target volume (PTV) and organs at risk (bladder, rectum, penile bulb, and femoral heads) were measured, means were calculated for both treatment methods, and dose-volume comparisons were made with 2-tailed, pairedmore » t-tests. The mean dose to the bladder was lower with VMAT at all measured volumes: 5, 10, 15, 25, 35, and 50% (p < 0.05). The mean doses to 5 and 10% of the rectum, the high-dose regions, were lower with VMAT (p < 0.05). The mean dose to 15% of the rectal volume was not significantly different (p = 0.95). VMAT exposed larger rectal volumes (25, 35, and 50%) to more radiation than fixed-field IMRT (p < 0.05). Average mean dose to the penile bulb (p < 0.05) and mean dose to 10% of the femoral heads (p < 0.05) were lower with VMAT. VMAT therapy for prostate cancer has dosimetric advantages for critical structures, notably for high-dose regions compared with fixed-field IMRT, without compromising PTV coverage. This may translate into reduced acute and chronic toxicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pixberg, Caroline; Koch, Raphael; Eich, Hans Theodor, E-mail: Hans.Eich@ukmuenster.de
Purpose: In the context of oncologic therapy for children, radiation therapy is frequently indicated. This study identified the frequency of and reasons for the development of high-grade acute toxicity and possible sequelae. Materials and Methods: Irradiated children have been prospectively documented since 2001 in the Registry for the Evaluation of Side Effects After Radiation in Childhood and Adolescence (RiSK) database in Germany and since 2008 in the registry for radiation therapy toxicity (RADTOX) in Sweden. Data were collected using standardized, published forms. Toxicity classification was based on Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Results: Asmore » of June 2013, 1500 children have been recruited into the RiSK database and 485 into the RADTOX registry leading to an analysis population of 1359 patients (age range 0-18). A total of 18.9% (n=257) of all investigated patients developed high-grade acute toxicity (grades 3/4). High-grade toxicity of the bone marrow was documented for 63.8% (n=201) of those patients, oral mucositis for 7.6% (n=24), and dermatitis for 7.6% (n=24). Patients with high-grade acute toxicity received concomitant chemotherapy more frequently (56%) than patients with no or lower acute toxicity (31.5%). In multivariate analyses, concomitant chemotherapy, diagnosis of Ewing sarcoma, and total radiation dose showed a statistically noticeable effect (P≤.05) on acute toxicity, whereas age, concomitant chemotherapy, Hodgkin lymphoma, Ewing sarcoma, total radiation dose, and acute toxicity influenced the time until maximal late toxicity. Conclusions: Generally, high-grade acute toxicity after irradiation in children and adolescence occurs in a moderate proportion of patients (18.9%). As anticipated, the probability of acute toxicity appeared to depend on the prescribed dose as well as concomitant chemotherapy. The occurrence of chronic toxicity correlates with the prior acute toxicity grade. Age seems to influence the time until maximal late toxicity but not the development of acute toxicity.« less
Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator
NASA Technical Reports Server (NTRS)
Chen, Dakai; Forney, James
2017-01-01
The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).
Ivannikov, A I; Zhumadilov, Zh; Gusev, B I; Miyazawa, Ch; Jiao, L; Skvortsov, V G; Stepanenko, V F; Takada, J; Hoshi, M
2002-08-01
Individual accumulated doses were determined by EPR spectroscopy of tooth enamel for 26 adult persons residing in territories adjacent to the Semipalatinsk Nuclear Test Site (SNTS). The absorbed dose values due to radiation from nuclear tests were obtained after subtracting the contribution of natural background radiation from the total accumulated dose. The determined dose values ranged up to 250 mGy, except for one person from Semipalatinsk city with a measured dose of 2.8 +/- 0.4 Gy. Increased dose values were determined for the individuals whose teeth were formed before 1962, the end of the atmospheric nuclear tests. These values were found to be significantly larger than those obtained for a group of younger residents of heavily exposed territories and the residents of territories not exposed to radioactive fallout. These increased dose values are consistent with those based on officially registered data for the Northeastern part of Kazakstan adjacent to SNTS, which was exposed to high levels of radioactive fallout from nuclear tests in period 1949-1962.
Barron, Heather W; Roberts, Royce E; Latimer, Kenneth S; Hernandez-Divers, Stephen; Northrup, Nicole C
2009-03-01
Currently used dosages for external-beam megavoltage radiation therapy in birds have been extrapolated from mammalian patients and often appear to provide inadequate doses of radiation for effective tumor control. To determine the tolerance doses of cutaneous and mucosal tissues of normal birds in order to provide more effective radiation treatment for tumors that have been shown to be radiation responsive in other species, ingluvial mucosa and the skin over the ingluvies of 9 ring-necked parakeets (Psittacula krameri) were irradiated in 4-Gy fractions to a total dose of either 48, 60, or 72 Gy using an isocentric cobalt-60 teletherapy unit. Minimal radiation-induced epidermal changes were present in the high-dose group histologically. Neither dose-related acute nor chronic radiation effects could be detected in any group grossly in cutaneous or mucosal tissue over a 9-month period. Radiation doses of 72 Gy in 4-Gy fractions were well tolerated in the small number of ring-necked parakeets in this initial tolerance dose study.
Bai, Penggang; Du, Min; Ni, Xiaolei; Ke, Dongzhong; Tong, Tong
2017-01-01
The combination external-beam radiotherapy and high-dose-rate brachytherapy is a standard form of treatment for patients with locally advanced uterine cervical cancer. Personalized radiotherapy in cervical cancer requires efficient and accurate dose planning and assessment across these types of treatment. To achieve radiation dose assessment, accurate mapping of the dose distribution from HDR-BT onto EBRT is extremely important. However, few systems can achieve robust dose fusion and determine the accumulated dose distribution during the entire course of treatment. We have therefore developed a toolbox (FZUImageReg), which is a user-friendly dose fusion system based on hybrid image registration for radiation dose assessment in cervical cancer radiotherapy. The main part of the software consists of a collection of medical image registration algorithms and a modular design with a user-friendly interface, which allows users to quickly configure, test, monitor, and compare different registration methods for a specific application. Owing to the large deformation, the direct application of conventional state-of-the-art image registration methods is not sufficient for the accurate alignment of EBRT and HDR-BT images. To solve this problem, a multi-phase non-rigid registration method using local landmark-based free-form deformation is proposed for locally large deformation between EBRT and HDR-BT images, followed by intensity-based free-form deformation. With the transformation, the software also provides a dose mapping function according to the deformation field. The total dose distribution during the entire course of treatment can then be presented. Experimental results clearly show that the proposed system can achieve accurate registration between EBRT and HDR-BT images and provide radiation dose warping and fusion results for dose assessment in cervical cancer radiotherapy in terms of high accuracy and efficiency. PMID:28388623
Dankers, Frank; Wijsman, Robin; Troost, Esther G C; Monshouwer, René; Bussink, Johan; Hoffmann, Aswin L
2017-05-07
In our previous work, a multivariable normal-tissue complication probability (NTCP) model for acute esophageal toxicity (AET) Grade ⩾2 after highly conformal (chemo-)radiotherapy for non-small cell lung cancer (NSCLC) was developed using multivariable logistic regression analysis incorporating clinical parameters and mean esophageal dose (MED). Since the esophagus is a tubular organ, spatial information of the esophageal wall dose distribution may be important in predicting AET. We investigated whether the incorporation of esophageal wall dose-surface data with spatial information improves the predictive power of our established NTCP model. For 149 NSCLC patients treated with highly conformal radiation therapy esophageal wall dose-surface histograms (DSHs) and polar dose-surface maps (DSMs) were generated. DSMs were used to generate new DSHs and dose-length-histograms that incorporate spatial information of the dose-surface distribution. From these histograms dose parameters were derived and univariate logistic regression analysis showed that they correlated significantly with AET. Following our previous work, new multivariable NTCP models were developed using the most significant dose histogram parameters based on univariate analysis (19 in total). However, the 19 new models incorporating esophageal wall dose-surface data with spatial information did not show improved predictive performance (area under the curve, AUC range 0.79-0.84) over the established multivariable NTCP model based on conventional dose-volume data (AUC = 0.84). For prediction of AET, based on the proposed multivariable statistical approach, spatial information of the esophageal wall dose distribution is of no added value and it is sufficient to only consider MED as a predictive dosimetric parameter.
Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R
2012-02-01
There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) < 0.5 µmol l(-1) up to -35% in patients with MTX C(24) > 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.
NASA Astrophysics Data System (ADS)
Dankers, Frank; Wijsman, Robin; Troost, Esther G. C.; Monshouwer, René; Bussink, Johan; Hoffmann, Aswin L.
2017-05-01
In our previous work, a multivariable normal-tissue complication probability (NTCP) model for acute esophageal toxicity (AET) Grade ⩾2 after highly conformal (chemo-)radiotherapy for non-small cell lung cancer (NSCLC) was developed using multivariable logistic regression analysis incorporating clinical parameters and mean esophageal dose (MED). Since the esophagus is a tubular organ, spatial information of the esophageal wall dose distribution may be important in predicting AET. We investigated whether the incorporation of esophageal wall dose-surface data with spatial information improves the predictive power of our established NTCP model. For 149 NSCLC patients treated with highly conformal radiation therapy esophageal wall dose-surface histograms (DSHs) and polar dose-surface maps (DSMs) were generated. DSMs were used to generate new DSHs and dose-length-histograms that incorporate spatial information of the dose-surface distribution. From these histograms dose parameters were derived and univariate logistic regression analysis showed that they correlated significantly with AET. Following our previous work, new multivariable NTCP models were developed using the most significant dose histogram parameters based on univariate analysis (19 in total). However, the 19 new models incorporating esophageal wall dose-surface data with spatial information did not show improved predictive performance (area under the curve, AUC range 0.79-0.84) over the established multivariable NTCP model based on conventional dose-volume data (AUC = 0.84). For prediction of AET, based on the proposed multivariable statistical approach, spatial information of the esophageal wall dose distribution is of no added value and it is sufficient to only consider MED as a predictive dosimetric parameter.
2013-05-07
Breast Cancer; Leukemia; Lymphoma; Multiple Myeloma and Plasma Cell Neoplasm; Testicular Germ Cell Tumor; Unspecified Adult Solid Tumor, Protocol Specific; Unspecified Childhood Solid Tumor, Protocol Specific
NASA Technical Reports Server (NTRS)
Ferl, J. E.; Long, E. R., Jr.
1981-01-01
Infrared (IR) spectroscopy and tensile modulus testing were used to evaluate the importance of experimental procedure on changes in properties of pyromellitic dianhydride-p,p prime-oxydianiline film exposed to electron radiation. The radiation exposures were accelerated, approximate equivalents to the total dose expected for a 30 year mission in geosynchronous Earth orbit. The change in the tensile modulus depends more on the dose rate and the time interval between exposure and testing than on total dose. The IR data vary with both total dose and dose rate. A threshold dose rate exists below which reversible radiation effects on the IR spectra occur. Above the threshold dose rate, irreversible effects occur with the appearance of a new band. Post-irradiation and in situ IR absorption bands are significantly different. It is suggested that the electron radiation induced metastable, excites molecular states.
Blazer, V.S.; Densmore, Christine L.; Schill, W.B.; Cartwright, Deborah D.; Page, S.J.
2004-01-01
The susceptibility of lake trout Salvelinus namaycush, rainbow trout Oncorhynchus mykiss and Atlantic salmon Salmo salar to Myxobolus cerebralis, the causative agent of whirling disease, was compared in controlled laboratory exposures. A total of 450 (225 for each dose) fry for each species were exposed to a low (200 spores per fish) or high (2000 spores per fish) dose of the infective triactinomyxon. At 22 wk post-exposure, 60 fish from each group, as well as controls for each species, were examined for clinical signs (whirling behavior, blacktail, deformed heads and skeletal deformities), microscopic lesions, and presence of spores. Rainbow trout were highly susceptible to infection, with 100% being positive for spores and with microscopic pathological changes in both exposure groups. Rainbow trout were the only species to show whirling behavior and blacktail. Atlantic salmon were less susceptible, with only 44 and 61% being positive for spores, respectively, in the low and high dose groups, while 68 and 75%, respectively, had microscopic pathology associated with cartilage damage. Rainbow trout heads contained mean spore concentrations of 2.2 (low dose) or 4.0 (high dose) ?? 106 spores g tissue-1. The means for positive Atlantic salmon (not including zero values) were 1.7 (low) and 7.4 (high) ?? 104 spores g tissue-1. Lake trout showed no clinical signs of infection, were negative for spores in both groups and showed no histopathological signs of M. cerebralis infection.
Blazer, V S; Densmore, C L; Schill, W B; Cartwright, D D; Page, S J
2004-01-28
The susceptibility of lake trout Salvelinus namaycush, rainbow trout Oncorhynchus mykiss and Atlantic salmon Salmo salar to Myxobolus cerebralis, the causative agent of whirling disease, was compared in controlled laboratory exposures. A total of 450 (225 for each dose) fry for each species were exposed to a low (200 spores per fish) or high (2000 spores per fish) dose of the infective triactinomyxon. At 22 wk post-exposure, 60 fish from each group, as well as controls for each species, were examined for clinical signs (whirling behavior, blacktail, deformed heads and skeletal deformities), microscopic lesions, and presence of spores. Rainbow trout were highly susceptible to infection, with 100% being positive for spores and with microscopic pathological changes in both exposure groups. Rainbow trout were the only species to show whirling behavior and blacktail. Atlantic salmon were less susceptible, with only 44 and 61% being positive for spores, respectively, in the low and high dose groups, while 68 and 75%, respectively, had microscopic pathology associated with cartilage damage. Rainbow trout heads contained mean spore concentrations of 2.2 (low dose) or 4.0 (high dose) x 10(6) spores g tissue(-1). The means for positive Atlantic salmon (not including zero values) were 1.7 (low) and 7.4 (high) x 10(4) spores g tissue(-1). Lake trout showed no clinical signs of infection, were negative for spores in both groups and showed no histopathological signs of M. cerebralis infection.
Sun, Hao; Xue, Hua-dan; Jin, Zheng-yu; Wang, Xuan; Chen, Yu; He, Yong-lan; Zhang, Da-ming; Zhu, Liang; Wang, Yun; Qi, Bing; Xu, Kai; Wang, Ming
2014-10-01
To retrospectively evaluate the clinical feasibility of high-pitch excretory phase images during dual-source CT urography with Stellar photon detector. Totally 100 patients received dual-source CT high-pitch urinary excretory phase scanning with Stellar photon detector [80 kV, ref.92 mAs, CARE Dose 4D and CARE kV, pitch of 3.0, filter back projection reconstruction algorithm (FBP)] (group A). Another 100 patients received dual-source CT high-pitch urinary excretory phase scanning with common detector(100 kV, ref.140 mAs, CARE Dose 4D, pitch of 3.0, FBP) (group B). Quantitative measurement of CT value of urinary segments (Hounsfield units), image noise (Hounsfield units), and effective radiation dose (millisievert) were compared using independent-samples t test between two groups. Urinary system subjective opacification scores were compared using Mann-Whitney U test between two groups. There was no significant difference in subjective opacification score of intrarenal collecting system and ureters between two groups (all P>0.05). The group A images yielded significantly higher CT values of all urinary segments (all P<0.01). There was no significant difference in image noise (P>0.05). The effective radiation dose of group A (1.1 mSv) was significantly lower than that of group B (3.79 mSv) (P<0.01). High-pitch low-tube-voltage during excretory phase dual-source CT urography with Stellar photon detector is feasible, with acceptable image noise and lower radiation dose.
Application of TXRF for ion implanter dose matching experiments
NASA Astrophysics Data System (ADS)
Frost, M. R.; French, M.; Harris, W.
2004-06-01
Secondary ion mass spectrometry (SIMS) has been utilized for many years to measure the dose of ion implants in silicon for the purpose of verifying the ability of ion implantation equipment to accurately and reproducibly implant the desired species at the target dose. The development of statistically and instrumentally rigorous protocols has lead to high confidence levels, particularly with regard to accuracy and short-term repeatability. For example, high-dose, high-energy B implant dosimetry can be targeted to within ±1%. However, performing dose determination experiments using SIMS does have undesirable aspects, such as being highly labor intensive and sample destructive. Modern total reflection X-ray fluorescence (TXRF) instruments are equipped with capabilities for full 300 mm wafer handling, automated data acquisition software and intense X-ray sources. These attributes enable the technique to overcome the SIMS disadvantages listed above, as well as provide unique strengths that make it potentially highly amenable to implanter dose matching. In this paper, we report on data collected to date that provides confidence that TXRF is an effective and economical method to perform these measurements within certain limitations. We have investigated a number of ion implanted species that are within the "envelope" of TXRF application. This envelope is defined by a few important parameters. Species: For the anode materials used in the more common X-ray sources on the market, each has its own set of elements that can be detected. We have investigated W and Mo X-ray sources, which are the most common in use in commercial instrumentation. Implant energy: In general, if the energy of the implanted species is too high (or more specifically, the distribution of the implanted species is too deep), the amount of dopant not detected by TXRF may be significant, increasing the error of the measurement. Therefore, for each species investigated, the implant energy cannot exceed a certain level. Dose: Logically, as the implanted dose falls below a certain point, the concentration will be below the TXRF detection limit. In addition to the improved precision of TXRF over SIMS for dose matching, a number of other advantages will be discussed.
Kišidayová, Svetlana; Pristaš, Peter; Zimovčáková, Michaela; Blanár Wencelová, Monika; Homol'ová, Lucia; Mihaliková, Katarína; Čobanová, Klaudia; Grešáková, Ľubomíra; Váradyová, Zora
2018-01-01
Little is known about the effects of the high dose and types of manganese supplements on rumen environment at manganese intake level close above the limit of 150 mg/kg of dry feed matter. The effects of high dose of two manganese supplements (organic and inorganic) on rumen microbial ecosystem after four months of treatment of 18 lambs divided into three treatment groups were studied. We examined the enzyme activities (α-amylase, xylanase, and carboxymethyl cellulase), total and differential microscopic counts of rumen ciliates, total microscopic counts of bacteria, and fingerprinting pattern of the eubacterial and ciliates population analyzed by PCR-DGGE. Lambs were fed a basal diet with a basal Mn content (34.3 mg/kg dry matter; control) and supplemented either with inorganic manganous sulfate or organic Mn-chelate hydrate (daily 182.7, 184 mg/kg dry matter of feed, respectively). Basal diet, offered twice daily, consisted of ground barley and hay (268 and 732 g/kg dry matter per animal and day). The rumens of the lambs harbored ciliates of the genera of Entodinium, Epidinium, Diplodinium, Eudiplodinium, Dasytricha, and Isotricha. No significant differences between treatment groups were observed in the total ciliate number, the number of ciliates at the genus level, as well as the total number of bacteria. Organic Mn did decrease the species richness and diversity of the eubacterial population examined by PCR-DGGE. No effects of type of Mn supplement on the enzyme activities were observed. In comparison to the control, α-amylase specific activities were decreased and carboxymethyl-cellulase specific activities were increased by the Mn supplements. Xylanase activities were not influenced. In conclusion, our results suggested that the intake of tested inorganic and organic manganese supplements in excess may affect the specific groups of eubacteria. More studies on intake of Mn supplements at a level close to the limit can reveal if the changes in microbial population impact remarkably the other rumen enzymatic activities.
Pristaš, Peter; Zimovčáková, Michaela; Blanár Wencelová, Monika; Homol'ová, Lucia; Mihaliková, Katarína; Čobanová, Klaudia; Grešáková, Ľubomíra; Váradyová, Zora
2018-01-01
Little is known about the effects of the high dose and types of manganese supplements on rumen environment at manganese intake level close above the limit of 150 mg/kg of dry feed matter. The effects of high dose of two manganese supplements (organic and inorganic) on rumen microbial ecosystem after four months of treatment of 18 lambs divided into three treatment groups were studied. We examined the enzyme activities (α-amylase, xylanase, and carboxymethyl cellulase), total and differential microscopic counts of rumen ciliates, total microscopic counts of bacteria, and fingerprinting pattern of the eubacterial and ciliates population analyzed by PCR-DGGE. Lambs were fed a basal diet with a basal Mn content (34.3 mg/kg dry matter; control) and supplemented either with inorganic manganous sulfate or organic Mn-chelate hydrate (daily 182.7, 184 mg/kg dry matter of feed, respectively). Basal diet, offered twice daily, consisted of ground barley and hay (268 and 732 g/kg dry matter per animal and day). The rumens of the lambs harbored ciliates of the genera of Entodinium, Epidinium, Diplodinium, Eudiplodinium, Dasytricha, and Isotricha. No significant differences between treatment groups were observed in the total ciliate number, the number of ciliates at the genus level, as well as the total number of bacteria. Organic Mn did decrease the species richness and diversity of the eubacterial population examined by PCR-DGGE. No effects of type of Mn supplement on the enzyme activities were observed. In comparison to the control, α-amylase specific activities were decreased and carboxymethyl-cellulase specific activities were increased by the Mn supplements. Xylanase activities were not influenced. In conclusion, our results suggested that the intake of tested inorganic and organic manganese supplements in excess may affect the specific groups of eubacteria. More studies on intake of Mn supplements at a level close to the limit can reveal if the changes in microbial population impact remarkably the other rumen enzymatic activities. PMID:29324899
Sahgal, Arjun; Chan, Michael W; Atenafu, Eshetu G; Masson-Cote, Laurence; Bahl, Gaurav; Yu, Eugene; Millar, Barbara-Ann; Chung, Caroline; Catton, Charles; O'Sullivan, Brian; Irish, Jonathan C; Gilbert, Ralph; Zadeh, Gelareh; Cusimano, Michael; Gentili, Fred; Laperriere, Normand J
2015-06-01
We report our preliminary outcomes following high-dose image-guided intensity modulated radiotherapy (IG-IMRT) for skull base chordoma and chondrosarcoma. Forty-two consecutive IG-IMRT patients, with either skull base chordoma (n = 24) or chondrosarcoma (n = 18) treated between August 2001 and December 2012 were reviewed. The median follow-up was 36 months (range, 3-90 mo) in the chordoma cohort, and 67 months (range, 15-125) in the chondrosarcoma cohort. Initial surgery included biopsy (7% of patients), subtotal resection (57% of patients), and gross total resection (36% of patients). The median IG-IMRT total doses in the chondrosarcoma and chordoma cohorts were 70 Gy and 76 Gy, respectively, delivered with 2 Gy/fraction. For the chordoma and chondrosarcoma cohorts, the 5-year overall survival and local control rates were 85.6% and 65.3%, and 87.8% and 88.1%, respectively. In total, 10 patients progressed locally: 8 were chordoma patients and 2 chondrosarcoma patients. Both chondrosarcoma failures were in higher-grade tumors (grades 2 and 3). None of the 8 patients with grade 1 chondrosarcoma failed, with a median follow-up of 77 months (range, 34-125). There were 8 radiation-induced late effects-the most significant was a radiation-induced secondary malignancy occurring 6.7 years following IG-IMRT. Gross total resection and age were predictors of local control in the chordoma and chondrosarcoma patients, respectively. We report favorable survival, local control and adverse event rates following high dose IG-IMRT. Further follow-up is needed to confirm long-term efficacy. © The Author(s) 2014. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Park, Jeong Bae; Ha, Jong-Won; Jung, Hae-Ok; Rhee, Moo-Yong
2014-10-01
Measurement of central blood pressure provides prognostic information beyond conventional peripheral blood pressure (BP). However, few studies have directly compared the effects of antihypertensives on central hemodynamics. This study investigated the effects of a low-dose combination of nifedipine Gastrointestinal Therapeutic System (GITS) and valsartan versus high-dose monotherapy with either agent in reducing central BP in essential hypertension inadequately controlled by low-dose monotherapy. In this prospective, open-label, randomized, active-controlled, multicenter 8-week study, patients not meeting the target BP after 4 weeks of treatment with low-dose monotherapy were randomized to receive nifedipine GITS 30 mg plus valsartan 80 mg (N30+V80), nifedipine GITS 60 mg (N60), or valsartan 160 mg (V160) for a further 4 weeks. Central hemodynamics were measured by applanation tonometry. A total of 391 patients were enrolled. Reduction in central systolic BP from baseline to week 8, the primary efficacy variable, was significantly greater in the N30+V80 group (-27.2±14.7 mmHg) and the N60 group (-27.1±16.5 mmHg) compared with V160 group (-14.4±16.6 mmHg). Decrease in the augmentation index in the N60 group was significantly greater compared with V160 alone, without differences between combination therapy and either high-dose monotherapy. Decreases in brachial systolic BP were significantly greater in the N30+V80 and N60 groups than in the V160 group. By multiple regression analysis, most differences in drug effects on central hemodynamics disappeared after controlling for changes in peripheral BP. A low rate of adverse events occurred in all treatment groups. A low-dose combination of nifedipine GITS plus valsartan or high-dose nifedipine was more effective in improving central hemodynamics than high-dose valsartan in patients with hypertension, mostly because of the improvement in peripheral (brachial) hemodynamics.
Introducing iron isomaltoside 1000 (Monofer®)-development rationale and clinical experience.
Kalra, Philip A
2011-06-01
Patients with chronic kidney disease (CKD) often suffer from iron deficiency anaemia necessitating treatment with intravenous (IV) iron. Several studies demonstrate that oral iron is insufficient in these patients and that IV supplementation is a more effective treatment. Until now, use of available parenteral iron preparations has been limited by dosing schedules and the need, in some cases, for a test dose, and despite the availability of a range of different IV iron compounds, there is still a need for improved compounds. The new IV iron, iron isomaltoside 1000 Monofer®, is composed of iron and chemically modified isomalto-oligosaccharides which have a mean molecular weight of 1000 Da and consist predominantly of 3-5 glucose units. In contrast to dextrans, the carbohydrate isomaltoside 1000 is a linear and unbranched structure with theoretically a low immunological potential. Hence, a test dose is not necessary. Iron isomaltoside 1000 contains strongly bound iron within the iron-isomaltoside formulation, which enables a controlled slow release of bioavailable iron to the iron-binding proteins, with potentially a reduced risk of free iron toxicity. This allows flexible dosing including high and rapid dosing securing convenient iron therapy for a wide range of patients. The development of Monofer® has been enthusiastically acknowledged by clinicians, and in 2009, there has been fast approval by European authorities via a decentralized registration procedure. This new IV iron is currently being marketed in several European countries. This article describes the development rationale and summarizes the clinical data assessing the use of iron isomaltoside 1000 administered without a test dose by either repeated bolus injections or fast high single iron infusions [defined as total dose infusion (TDI)] to patients suffering from CKD. Since CKD is associated with a high prevalence of cardiovascular disease, data from a small trial applying high single doses of iron isomatoside 1000 in patients with chronic heart failure (CHF) are also reviewed. Collectively, the available data demonstrate adequate efficacy and a good safety profile of iron isomaltoside 1000 in CKD and CHF patients even when administered without a test dose and as single rapid high-dose infusions.
El-Bahi, S M; Sroor, A; Mohamed, Gehan Y; El-Gendy, N S
2017-05-01
In this study, the activity concentrations of the natural radionuclides in phosphate rocks and its products were measured using a high- purity germanium detector (HPGe). The obtained activity results show remarkable wide variation in the radioactive contents for the different phosphate samples. The average activity concentration of 235 U, 238 U, 226 Ra, 232 Th and 40 K was found as (45, 1031, 786, 85 and 765Bq/kg) for phosphate rocks, (28, 1234, 457, 123 and 819Bq/kg) for phosphate fertilizers, (47, 663, 550, 79 and 870Bq/kg) for phosphogypsum and (25, 543, 409, 54 and 897Bq/kg) for single super phosphate respectively. Based on the measured activities, the radiological parameters (activity concentration index, absorbed gamma dose rate in outdoor and indoor and the corresponding annual effective dose rates and total excess lifetime cancer risk) were estimated to assess the radiological hazards. The total excess lifetime cancer risk (ELCR) has been calculated and found to be high in all samples, which related to high radioactivity, representing radiological risk for the health of the population. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fractionated irradiation of carbon beam and the isoeffect dose on acute reaction of skin
Uzawa, Akiko; Hirayama, Ryoichi; Matsumoto, Yoshitaka; Koda, Kana; Koike, Sachiko; Ando, Koichi; Furusawa, Yoshiya
2014-01-01
Purpose: The aim of this study was to clear any specific LETs cause change in skin reaction. We irradiated mice feet with mono-energetic and SOBP carbon ions, to obtain dose–response of early skin reaction at different LETs. Materials and methods: Mice: C3H/HeMsNrsf female mice aged 4 months old were used for this study. The animals were produced and maintained in specific pathogen-free (SPF) facilities. Irradiation: The mice right hind legs received daily fractionated irradiation ranged from single to six fractions. Carbon ions (12C6+) were accelerated by the HIMAC synchrotron to 290 MeV/u. Irradiation was conducted using horizontal carbon-ion beams with a dose rate of ∼3 Gy/min. We chose the LETs at entrance of plateau (20keV/μm) and the SOBP (proximal: 40 keV/μm, middle: 45 keV/μm, distal: 60 keV/μm, distal-end: 80 keV/μm). The reference beam was 137Cs gamma rays with a dose rate of 1.2 Gy/min. Skin reaction: Skin reaction of the irradiated legs was scored every other day, between the14th and 35th post-irradiation days. Our scoring scale consisted of seven steps, ranging from 0.5 to 3.5 [ 1]. The skin score analyzed a result by the method that described by Ando et al. [ 2]. The Fe-plot proposed by Douglas and Fowler was used as a multifraction linear quadratic model. A plot between the reciprocal of the isoeffect dose and the dose per fraction resulted in a straight line. Results: Required isoeffect total dose increased linearly with the fraction numbers on a semi-logarithmic chart at LET 20–60 keV/µm SOBP beam. The isoeffect total dose decreased with the increase in the LET. However, no increases in isoeffect total dose were observed at few fractionations at 80 keV/µm. (data not shown) Using an Fe-plot, we analyzed the isoeffect total dose to evaluate the dependence on Carbon beam, or gamma ray. When I irradiate it by gamma ray, an Fe-plot shows linearly. But, irradiated by Carbon beam, an Fe-plot bent at low fractions (Fig. 1). Conclusion: The LQ-model-based Fe-plot could not fit skin reaction at few fractions at high-LET. Clinical Trial Registration number if required: No.Fig. 1.The reciprocal of the isoeffect dose is plotted against the dose per fraction. (i) Gamma ray: Fe-plot was linear. (ii) C-ions: Fe-plot bent at low fractions.
Zhou, Rong-Yi; Wang, Jiao-Jiao; You, Yue; Sun, Ji-Chao; Song, Yu-Chen; Yuan, Hai-Xia; Han, Xin-Min
2017-05-01
To study the effect of baicalin on synaptosomal adenosine triphosphatase (ATPase) and lactate dehydrogenase (LDH) and its regulatory effect on the adenylate cyclase (AC)/cyclic adenosine monophosphate (cAMP)/protein kinase A (PKA) signaling pathway in rats with attention deficit hyperactivity disorder (ADHD). A total of 40 SHR rats were randomly divided into five groups: ADHD model, methylphenidate hydrochloride treatment (0.07 mg/mL), and low-dose (3.33 mg/mL), medium-dose (6.67 mg/mL), and high-dose (10 mg/mL) baicalin treatment (n=8 each). Eight WKY rats were selected as normal control group. Percoll density gradient centrifugation was used to prepare brain synaptosomes and an electron microscope was used to observe their structure. Colorimetry was used to measure the activities of ATPase and LDH in synaptosomes. ELISA was used to measure the content of AC, cAMP, and PKA. Compared with the normal control group, the ADHD model group had a significant reduction in the ATPase activity, a significant increase in the LDH activity, and significant reductions in the content of AC, cAMP, and PKA (P<0.05). Compared with the ADHD model group, the methylphenidate hydrochloride group and the medium- and high-dose baicalin groups had a significant increase in the ATPase activity (P<0.05), a significant reduction in the LDH activity (P<0.05), and significant increases in the content of AC, cAMP, and PKA (P<0.05). Compared with the methylphenidate hydrochloride group, the high-dose baicalin group had significantly greater changes in these indices (P<0.05). Compared with the low-dose baicalin group, the high-dose baicalin group had a significant increase in the ATPase activity (P<0.05); the medium- and high-dose baicalin groups had a significant reduction in the LDH activity (P<0.05) and significant increases in the content of AC, cAMP, and PKA (P<0.05). Compared with the medium-dose baicalin group, the high-dose baicalin group had a significant increase in the ATPase activity (P<0.05). Both methylphenidate hydrochloride and baicalin can improve synaptosomal ATPase and LDH activities in rats with ADHD. The effect of baicalin is dose-dependent, and high-dose baicalin has a significantly greater effect than methylphenidate hydrochloride. Baicalin exerts its therapeutic effect possibly by upregulating the AC/cAMP/PKA signaling pathway.
Metabolic changes in serum steroids induced by total-body irradiation of female C57B/6 mice.
Moon, Ju-Yeon; Shin, Hee-June; Son, Hyun-Hwa; Lee, Jeongae; Jung, Uhee; Jo, Sung-Kee; Kim, Hyun Sik; Kwon, Kyung-Hoon; Park, Kyu Hwan; Chung, Bong Chul; Choi, Man Ho
2014-05-01
The short- and long-term effects of a single exposure to gamma radiation on steroid metabolism were investigated in mice. Gas chromatography-mass spectrometry was used to generate quantitative profiles of serum steroid levels in mice that had undergone total-body irradiation (TBI) at doses of 0Gy, 1Gy, and 4Gy. Following TBI, serum samples were collected at the pre-dose time point and 1, 3, 6, and 9 months after TBI. Serum levels of progestins, progesterone, 5β-DHP, 5α-DHP, and 20α-DHP showed a significant down-regulation following short-term exposure to 4Gy, with the exception of 20α-DHP, which was significantly decreased at each of the time points measured. The corticosteroids 5α-THDOC and 5α-DHB were significantly elevated at each of the time points measured after exposure to either 1 or 4Gy. Among the sterols, 24S-OH-cholestoerol showed a dose-related elevation after irradiation that reached significance in the high dose group at the 6- and 9-month time points. Copyright © 2014 Elsevier Ltd. All rights reserved.
Keehan, S; Taylor, M L; Smith, R L; Dunn, L; Kron, T; Franich, R D
2016-12-01
Production of radioisotopes in medical linear accelerators (linacs) is of concern when the beam energy exceeds the threshold for the photonuclear interaction. Staff and patients may receive a radiation dose as a result of the induced radioactivity in the linac. Gamma-ray spectroscopy was used to identify the isotopes produced following the delivery of 18 MV photon beams from a Varian 21EX and an Elekta Synergy. The prominent radioisotopes produced include 187 W, 63 Zn, 56 Mn, 24 Na and 28 Al in both linac models. The dose rate was measured at the beam exit window (12.6 µSv in the first 10 min) following 18 MV total body irradiation (TBI) beams. For a throughput of 24 TBI patients per year, staff members are estimated to receive an annual dose of up to 750 μSv at the patient location. This can be further reduced to 65 μSv by closing the jaws before re-entering the treatment bunker. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Einstein, Andrew J.; Blankstein, Ron; Andrews, Howard; Fish, Mathews; Padgett, Richard; Hayes, Sean W.; Friedman, John D.; Qureshi, Mehreen; Rakotoarivelo, Harivony; Slomka, Piotr; Nakazato, Ryo; Bokhari, Sabahat; Di Carli, Marcello; Berman, Daniel S.
2015-01-01
SPECT myocardial perfusion imaging (MPI) plays a central role in coronary artery disease diagnosis; but concerns exist regarding its radiation burden. Compared to standard Anger-SPECT (A-SPECT) cameras, new high-efficiency (HE) cameras with specialized collimators and solid-state cadmium-zinc-telluride detectors offer potential to maintain image quality (IQ), while reducing administered activity and thus radiation dose to patients. No previous study has compared IQ, interpretation, total perfusion deficit (TPD), or ejection fraction (EF) in patients receiving both ultra-low-dose (ULD) imaging on a HE-SPECT camera and standard low-dose (SLD) A-SPECT imaging. Methods We compared ULD-HE-SPECT to SLD-A-SPECT imaging by dividing the rest dose in 101 patients at 3 sites scheduled to undergo clinical A-SPECT MPI using a same day rest/stress Tc-99m protocol. Patients received HE-SPECT imaging following an initial ~130 MBq (3.5mCi) dose, and SLD-A-SPECT imaging following the remainder of the planned dose. Images were scored visually by 2 blinded readers for IQ and summed rest score (SRS). TPD and EF were assessed quantitatively. Results Mean activity was 134 MBq (3.62 mCi) for ULD-HE-SPECT (effective dose 1.15 mSv) and 278 MBq (7.50 mCi, 2.39 mSv) for SLD-A-SPECT. Overall IQ was superior for ULD-HE-SPECT (p<0.0001), with twice as many studies graded excellent quality. Extracardiac activity and overall perfusion assessment were similar. Between-method correlations were high for SRS (r=0.87), TPD (r=0.91), and EF (r=0.88). Conclusion ULD-HE-SPECT rest imaging correlates highly with SLD-A-SPECT. It has improved image quality, comparable extracardiac activity, and achieves radiation dose reduction to 1 mSv for a single injection. PMID:24982439
Recent resurgence of mumps in the United States.
Dayan, Gustavo H; Quinlisk, M Patricia; Parker, Amy A; Barskey, Albert E; Harris, Meghan L; Schwartz, Jennifer M Hill; Hunt, Kae; Finley, Carol G; Leschinsky, Dennis P; O'Keefe, Anne L; Clayton, Joshua; Kightlinger, Lon K; Dietle, Eden G; Berg, Jeffrey; Kenyon, Cynthia L; Goldstein, Susan T; Stokley, Shannon K; Redd, Susan B; Rota, Paul A; Rota, Jennifer; Bi, Daoling; Roush, Sandra W; Bridges, Carolyn B; Santibanez, Tammy A; Parashar, Umesh; Bellini, William J; Seward, Jane F
2008-04-10
The widespread use of a second dose of mumps vaccine among U.S. schoolchildren beginning in 1990 was followed by historically low reports of mumps cases. A 2010 elimination goal was established, but in 2006 the largest mumps outbreak in two decades occurred in the United States. We examined national data on mumps cases reported during 2006, detailed case data from the most highly affected states, and vaccination-coverage data from three nationwide surveys. A total of 6584 cases of mumps were reported in 2006, with 76% occurring between March and May. There were 85 hospitalizations, but no deaths were reported; 85% of patients lived in eight contiguous midwestern states. The national incidence of mumps was 2.2 per 100,000, with the highest incidence among persons 18 to 24 years of age (an incidence 3.7 times that of all other age groups combined). In a subgroup analysis, 83% of these patients reported current college attendance. Among patients in eight highly affected states with known vaccination status, 63% overall and 84% between the ages of 18 and 24 years had received two doses of mumps vaccine. For the 12 years preceding the outbreak, national coverage of one-dose mumps vaccination among preschoolers was 89% or more nationwide and 86% or more in highly affected states. In 2006, the national two-dose coverage among adolescents was 87%, the highest in U.S. history. Despite a high coverage rate with two doses of mumps-containing vaccine, a large mumps outbreak occurred, characterized by two-dose vaccine failure, particularly among midwestern college-age adults who probably received the second dose as schoolchildren. A more effective mumps vaccine or changes in vaccine policy may be needed to avert future outbreaks and achieve the elimination of mumps. Copyright 2008 Massachusetts Medical Society.
Sartori, Ana Lucia; Minamisava, Ruth; Afonso, Eliane Terezinha; Policena, Gabriela Moreira; Pessoni, Grécia Carolina; Bierrenbach, Ana Luiza; Andrade, Ana Lucia
2017-02-15
Vaccination coverage is the usual metrics to evaluate the immunization programs performance. For the 10-valent pneumococcal conjugate (PCV10) vaccine, measuring the delay of vaccination is also important, particularly as younger children are at increased risk of disease. Routinely collected administrative data was used to assess the timeliness of PCV10 vaccination, and the factors associated with delay to receive the first and second doses, and the completion of the PCV10 3+1 schedule. A population-based retrospective cohort study was conducted with children born in 2012 in Central Brazil. Children who received the PCV10 first dose in public health services were followed-up until 23months of age. Timeliness of receiving each PCV10 dose at any given age was defined as receiving the dose within 28days grace period from the recommended age by the National Immunization Program. Log-binomial regression models were used to examine risk factors for delays of the first dose and the completion PCV10 3+1 schedule. In total, 14,282 children were included in the cohort of study. Delayed vaccination occurred in 9.4%, 23.8%, 36.8% and 39.9% children for the first, second, third and the booster doses, respectively. A total of 1912 children (12.8% of the cohort) were not adequately vaccinated at the 6months of life; 1,071 (7%) received the second dose after 6months of age, 784 (5.4%) did not receive the second dose, and 57 (0.4%) received the first dose after six months of life. A considerable delay was found in PCV10 third and booster doses. Almost 2 thousand children had not received the recommended PCV10 doses at 6months of age. Timeliness of vaccination is an issue in Brazil although high vaccination coverages. Copyright © 2017 Elsevier Ltd. All rights reserved.
SU-F-T-322: A Comparison of Two Si Detectors for in Vivo Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Talarico, O; Krylova, T; Lebedenko, I
Purpose: To compare two types of semiconductor detectors for in vivo dosimetry by their dependence from various parameters in different conditions. Methods: QED yellow (Sun Nuclear) and EDP (Scanditronix) Si detectors were radiated by a Varian Clinac 2300 ix with 6 and 18 MV energies. 10 cm thickness water equivalent phantom consisted of 30×30 cm{sup 2} squared plates was used for experiments. Dose dependencies for different beam angles (0 – 180°), field size (3–40 cm), dose (50 – 300 MU), and dose rates (50 – 300 MU/min) were obtained and calibrated with Standard Farmer chamber (PTW). Results: Reproducibility, linearity, dosemore » rate, angular dependence, and field size dependence were obtained for QED and EDP. They show no dose-rate dependence in available clinical dose rate range (100–600 MU/min). Both diodes have linear dependence with increasing the dose. Therefore even in case of high radiation therapy (including total body irradiation) it is not necessary to apply an additional correction during in vivo dosimetry. The diodes have different behavior for angular and field size dependencies. QED diode showed that dose value is stable for beam angles from 0 to 60°, for 60–180° correction factor has to be applied for each beam angle during in vivo measurements. For EDP diode dose value is sensitive to beam angle in whole range of angles. Conclusion: The study shows that QED diode is more suitable for in vivo dosimetry due to dose value independence from incident beam angle in the range 0–60°. There is no need in correction factors for increasing of dose and dose rate for both diodes. The next step will be to carry out measurements in non-standard conditions of total body irradiation. After this modeling of these experiments with Monte Carlo simulation for comparison calculated and obtained data is planned.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maneru, F; Gracia, M; Gallardo, N
2015-06-15
Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported frommore » the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.« less
Zhang, Xiao-ying; Wei, Wan-lin; Shu, Chang-cheng; Zhang, Ling; Tian, Guo-xiang
2013-02-05
To explore the effects of qishenyiqi gutta pills on myocardial hypertrophy of left ventricle and calcium/calmodulin dependent protein kinase II (CAMK II) in rats with renal hypertension and elucidate its intervention mechanism for myocardial hypertrophy. A total of 50 Wistar rats were randomly divided into 5 groups of sham-operation, control, high-dose qishenyiqi gutta pills, low-dose qishenyiqi gutta pills and valsartan (n = 10 each). The rat model of myocardial hypertrophy with renal hypertension was established by the 2-kidney 1-clip (2K1C) method. The experimental animals were divided into control, high-dose, low-dose and valsartan groups. At Week 5 postoperation, valsartan group received an oral dose of valsartan (30 mg×kg(-1)×d(-1)), high-dose and low-dose groups took qishenyiqi gutta pills (250 and 125 mg×kg(-1)×d(-1)) while sham-operation and control groups had the same dose of normal saline solution. Tail arterial pressure was detected weekly and continued for 8 weeks. At the end of Week 12, the animals were sacrificed to harvest myocardial tissue of left ventricle for detecting left ventricular mass index (LVMI). The collagen volume fraction (CVF) of myocardium was examined by Van Gieson staining, the activities of superoxide dismutase (SOD) and reactive oxygen species (ROS) were detected by enzyme-linked immunosorbent assay (ELISA) and the expression of CAMK II was detected by immunohistochemistry and Western blot. (1) Blood pressures were significantly higher in high-dose, low-dose and control groups than those in sham-operation and valsartan groups ((167.66 ± 11.48), (166.72 ± 13.51), (174.34 ± 14.52) vs (119.57 ± 6.30), (131.80 ± 12.49) mm Hg, P < 0.01). The changes of blood pressure had no significant difference between high-dose and low-dose groups. (2) LVMI and CVF increased significantly in high-dose, low-dose and valsartan groups versus sham-operation group (LVMI: (1.98 ± 0.16), (2.09 ± 0.14), (1.97 ± 0.17) vs (1.74 ± 0.17) g/kg; CVF: 0.94% ± 0.22%, 2.53% ± 0.61%, 0.81% ± 0.20% vs 0.45% ± 0.13%) (P < 0.01, P < 0.05), but decreased significantly versus control group (LVMI: (1.98 ± 0.16), (2.09 ± 0.14), (1.97 ± 0.17) vs (2.28 ± 0.28) g/kg; CVF: 0.94% ± 0.22%, 2.53% ± 0.61%, 0.81% ± 0.20% vs 4.73% ± 1.04%) (P < 0.01, P < 0.05). (3) The expression of CAMK II was significantly higher in high-dose, low-dose, valsartan and control groups than that in sham-operation group (65.9%, 95.3%, 84.8%, 160.1% vs 67.7%). And it was significantly lower in high-dose, low-dose and valsartan groups than that in control group (65.9%, 95.3%, 84.8% vs 160.1%). There was no statistical difference among high-dose, low-dose and valsartan groups. Qishenyiqi gutta pills may retard myocardial hypertrophy of left ventricle in rats with renal hypertension. And the mechanism is probably be correlated with its antioxidant activity and inhibited expression of myocardial CAMK II.
Templin, Thomas; Young, Erik F.; Smilenov, Lubomir B.
2013-01-01
Purpose Previously, we showed that microRNA (miRNA) signatures derived from the peripheral blood of mice are highly specific for both radiation energy (γ-rays or high linear energy transfer [LET] 56Fe ions) and radiation dose. Here, we investigate to what extent miRNA expression signatures derived from mouse blood can be used as biomarkers for exposure to 600 MeV proton radiation. Materials and methods We exposed mice to 600 MeV protons, using doses of 0.5 or 1.0 Gy, isolated total RNA at 6 h or 24 h after irradiation, and used quantitative real-time polymerase chain reaction (PCR) to determine the changes in miRNA expression. Results A total of 26 miRNA were differentially expressed after proton irradiation, in either one (77%) or multiple conditions (23%). Statistical classifiers based on proton, γ, and 56Fe-ion miRNA expression signatures predicted radiation type and proton dose with accuracies of 81% and 88%, respectively. Importantly, gene ontology analysis for proton-irradiated cells shows that genes targeted by radiation-induced miRNA are involved in biological processes and molecular functions similar to those controlled by miRNA in γ ray- and 56Fe-irradiated cells. Conclusions Mouse blood miRNA signatures induced by proton, γ, or 56Fe irradiation are radiation type- and dose-specific. These findings underline the complexity of the miRNA-mediated radiation response. PMID:22551419
Grémy, Olivier; Coudert, Sylvie; Renault, Daniel; Miccoli, Laurent
2017-11-01
While the efficacy of a protracted zinc (Zn)- or calcium (Ca)-diethylenetriaminepentaacetic acid (DTPA) treatment in reducing transuranic body burden has already been demonstrated, questions about therapeutic variables remain. In response to this, we designed animal experiments primarily to assess both the effect of fractionation of a given dose and the effect of the frequency of dose fraction, with the same total dose. In our study, rats were contaminated intravenously with plutonium (Pu) then treated several days later with Ca-DTPA given at once or in various split-dose regimens cumulating to the same total dose and spread over several days. Similar efficacies were induced by the injection of the total dose or by splitting the dose in several smaller doses, independent of the number of doses and the dose level per injection. In a second study, rats were pulmonary contaminated, and three weeks later they received a Ca-DTPA dose 11-fold higher than the maximal daily recommended dose, administered either as a single bolus or as numerous multiple injections cumulating to the same dose, based on different injection frequency schedules. Independent of frequency schedule, the various split-dose regimens spread over weeks/months were as efficient as single delivery of the total dose in mobilizing lung plutonium, and had a therapeutic advantage for removal of retained hepatic and bone plutonium burdens. We concluded that cumulative dose level was a therapeutic variable of greater importance than the distribution of split doses for the success of a repeated treatment regimen on retained tissue plutonium. In addition, pulmonary administration of clodronate, which aims at killing alveolar macrophages and subsequently releasing their plutonium content, and which is associated with a continuous Ca-DTPA infusion regimen, suggested that the efficacy of injected Ca-DTPA in decorporating lung deposit is limited, due to its restricted penetration into alveolar macrophages and not because plutonium, as a physicochemical form, is unavailable for chelation.
[Prevention of adriamycin-induced alopecia by scalp hypothermia with a deep-frozen Duncool-Cap].
Konishi, Y; Kuroki, T
1988-11-01
In order to prevent Adriamycin (ADM)-induced alopecia, scalp hypothermia with a Duncool-Cap frozen in a freezer at -70 degrees C was carried out. Of the 18 patients studied, one patient given total ADM doses of 240 mg developed alopecia of moderate degree, and another patient treated with ADM at a dose level of 50 mg developed mild alopecia. Alopecia could be almost completely prevented in 10 of the 11 patients given total ADM doses of 100 mg or less, and in 6 of the 7 patients given total doses of 200 mg or more.
Ajish, T P; Praveen, V P; Nisha, B; Kumar, Harish
2014-11-01
There are recommendations regarding the total dose of hydrocortisone to be administered in the treatment of classical congenital adrenal hyperplasia (CAH) to achieve the twin objectives of glucocorticoid replacement and control of hyperandrogenism. However, there is evidence gap regarding the breakup, timing and type of the steroid regimen. Efficacy of three different glucocorticoid regimens having the same total dose of steroid, differing in either the timing or type of evening steroid administered, in achieving biochemical control of the disease was assessed. The study was done in 13 prepubertal children with classical CAH over a 6-month period with 2 months devoted to each regimen. We used a prospective cross-over design using 10-15 mg/m(2) total dose of hydrocortisone. Two-fifths of the total dose of hydrocortisone was administered in the morning and one-fifth of the total dose was administered at noon in all the regimens. The regimens differed in the timing of the evening dose of hydrocortisone, 06.00-07.00 pm in regimen 1 and 09.00-10.00 pm in regimen 2. The third regimen had the evening dose of hydrocortisone replaced by an equivalent dose of prednisolone suspension which was administered at 10.00 pm. Serum 17-hydroxyprogesterone and testosterone levels were compared to assess the efficacy of treatment regimens. The three different regimens were found to be similar in their ability to control 17-hydroxyprogesterone and testosterone levels. The percentage of patients with predefined criteria for biochemically controlled disease was similar in all the three regimens. However, there was a trend toward better control of 17-hydroxyprogesterone levels in patients receiving evening dose of prednisolone. There is no significant advantage in administering the hydrocortisone dose late at night in patients with classical CAH.
/sup 125/I interstitial implants in the RIF-1 murine flank tumor: an animal model for brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, M.; Gutin, P.H.; Weaver, D.A.
1982-09-01
The development of a model for interstitial brachytherapy that uses high-activity, removable /sup 125/I sources in the RIF-1 murine flank tumor is reported. Experimental end points are clonogenic cell and tumor regrowth delay assays. For the clonogenic cell assay, interestitial radiation is delivered at total doses of 500-10,000 rad at dose rates of 0.9-2.7 rad/min to cells in annuli of tissue in the tumor. Dose-survival curves are characterized by an initial shoulder followed by a straight (exponential) portion, with D/sub 0/ similar to that of the curve obtained by external irradiation of the RIF-1 tumor in a self-contained cesium irradiatormore » at similar dose rates. Tumor regrowth curves have been obtained for minimum tumor doses of 500-5000 rad; marked tumor regression has been observed with minimum tumor doses as low as 2000 rad, but results are not as reproducible as the results obtained with the clonogenic cell assay.« less
Uncertainty analysis of absorbed dose calculations from thermoluminescence dosimeters.
Kirby, T H; Hanson, W F; Johnston, D A
1992-01-01
Thermoluminescence dosimeters (TLD) are widely used to verify absorbed doses delivered from radiation therapy beams. Specifically, they are used by the Radiological Physics Center for mailed dosimetry for verification of therapy machine output. The effects of the random experimental uncertainties of various factors on dose calculations from TLD signals are examined, including: fading, dose response nonlinearity, and energy response corrections; reproducibility of TL signal measurements and TLD reader calibration. Individual uncertainties are combined to estimate the total uncertainty due to random fluctuations. The Radiological Physics Center's (RPC) mail out TLD system, utilizing throwaway LiF powder to monitor high-energy photon and electron beam outputs, is analyzed in detail. The technique may also be applicable to other TLD systems. It is shown that statements of +/- 2% dose uncertainty and +/- 5% action criterion for TLD dosimetry are reasonable when related to uncertainties in the dose calculations, provided the standard deviation (s.d.) of TL readings is 1.5% or better.
de Jesus, Fillipe M; Magalhães, Luis A G; Kodlulovich, Simone
2016-11-01
A pilot study of dose indicators in paediatric computed tomography (CT) was conducted to prove the need to establish diagnostic reference levels (DRLs) for the county of Rio de Janeiro. The dose descriptors were estimated from the beam dosimetry by applying the protocols used in each examination. The total patient sample included 279 children. Regarding the comparison of the dose-length product values among the hospitals, the high-resolution chest CT scans were distinguished among the three types of examinations, due to the discrepancies of 1148 % (1-5 y age group) and 2248 % (5-10 y age group) presented in Hospital A's dose-length product values relative to Hospital D's dose-length product values. The results showed that without DRL, the dose variation can be significant between hospitals in the same county for the same age group in the same examination. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Basu, Arpita; Betts, Nancy M.; Nguyen, Angel; Newman, Emily D.; Fu, Dongxu; Lyons, Timothy J.
2014-01-01
Dietary flavonoid intake, especially berry flavonoids, has been associated with reduced risks of cardiovascular disease (CVD) in large prospective cohorts. Few clinical studies have examined the effects of dietary berries on CVD risk factors. We examined the hypothesis that freeze-dried strawberries (FDS) improve lipid and lipoprotein profiles and lower biomarkers of inflammation and lipid oxidation in adults with abdominal adiposity and elevated serum lipids. In a randomized dose-response controlled trial, 60 volunteers [5 men and 55 women; aged 49 ± 10 y; BMI: 36 ± 5 kg/m2 (means ± SDs)] were assigned to consume 1 of the following 4 beverages for 12 wk: 1) low-dose FDS (LD-FDS; 25 g/d); 2) low-dose control (LD-C); 3) high-dose FDS (HD-FDS; 50 g/d); and 4) high-dose control (HD-C). Control beverages were matched for calories and total fiber. Blood draws, anthropometrics, blood pressure, and dietary data were collected at screening (0 wk) and after 12-wk intervention. Dose-response analyses revealed significantly greater decreases in serum total and LDL cholesterol and nuclear magnetic resonance (NMR)–derived small LDL particle concentration in HD-FDS [33 ± 6 mg/dL, 28 ± 7 mg/dL, and 301 ± 78 nmol/L, respectively (means ± SEMs)] vs. LD-FDS (−3 ± 11 mg/dL, −3 ± 9 mg/dL, and −28 ± 124 nmol/L, respectively) over 12 wk (0–12 wk; all P < 0.05). Compared with controls, only the decreases in total and LDL cholesterol in HD-FDS remained significant vs. HD-C (0.7 ± 12 and 1.4 ± 9 mg/dL, respectively) over 12 wk (0–12 wk; all P < 0.05). Both doses of strawberries showed a similar decrease in serum malondialdehyde at 12 wk (LD-FDS: 1.3 ± 0.2 μmol/L; HD-FDS: 1.2 ± 0.1 μmol/L) vs. controls (LD-C: 2.1 ± 0.2 μmol/L; HD-C: 2.3 ± 0.2 μmol/L) (P < 0.05). In general, strawberry intervention did not affect any measures of adiposity, blood pressure, glycemia, and serum concentrations of HDL cholesterol and triglycerides, C-reactive protein, and adhesion molecules. Thus, HD-FDS exerted greater effects in lowering serum total and LDL cholesterol and NMR-derived small LDL particles vs. LD-FDS in the 12-wk study. These findings warrant additional investigation in larger trials. This trial was registered at clinicaltrials.gov as NCT01883401. PMID:24670970
Del Gobbo, Liana C; Falk, Michael C; Feldman, Robin; Lewis, Kara; Mozaffarian, Dariush
2015-12-01
The effects of nuts on major cardiovascular disease (CVD) risk factors, including dose-responses and potential heterogeneity by nut type or phytosterol content, are not well established. We examined the effects of tree nuts (walnuts, pistachios, macadamia nuts, pecans, cashews, almonds, hazelnuts, and Brazil nuts) on blood lipids [total cholesterol, low-density lipoprotein (LDL) cholesterol, high-density lipoprotein, and triglycerides], lipoproteins [apolipoprotein A1, apolipoprotein B (ApoB), and apolipoprotein B100], blood pressure, and inflammation (C-reactive protein) in adults aged ≥18 y without prevalent CVD. We conducted a systematic review and meta-analysis following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Two investigators screened 1301 potentially eligible PubMed articles in duplicate. We calculated mean differences between nut intervention and control arms, dose-standardized to one 1-oz (28.4 g) serving/d, by using inverse-variance fixed-effects meta-analysis. Dose-response for nut intake was examined by using linear regression and fractional polynomial modeling. Heterogeneity by age, sex, background diet, baseline risk factors, nut type, disease condition, duration, and quality score was assessed with meta-regression. Publication bias was evaluated by using funnel plots and Egger's and Begg's tests. Sixty-one trials met eligibility criteria (n = 2582). Interventions ranged from 3 to 26 wk. Nut intake (per serving/d) lowered total cholesterol (-4.7 mg/dL; 95% CI: -5.3, -4.0 mg/dL), LDL cholesterol (-4.8 mg/dL; 95% CI: -5.5, -4.2 mg/dL), ApoB (-3.7 mg/dL; 95% CI: -5.2, -2.3 mg/dL), and triglycerides (-2.2 mg/dL; 95% CI: -3.8, -0.5 mg/dL) with no statistically significant effects on other outcomes. The dose-response between nut intake and total cholesterol and LDL cholesterol was nonlinear (P-nonlinearity < 0.001 each); stronger effects were observed for ≥60 g nuts/d. Significant heterogeneity was not observed by nut type or other factors. For ApoB, stronger effects were observed in populations with type 2 diabetes (-11.5 mg/dL; 95% CI: -16.2, -6.8 mg/dL) than in healthy populations (-2.5 mg/dL; 95% CI: -4.7, -0.3 mg/dL) (P-heterogeneity = 0.015). Little evidence of publication bias was found. Tree nut intake lowers total cholesterol, LDL cholesterol, ApoB, and triglycerides. The major determinant of cholesterol lowering appears to be nut dose rather than nut type. Our findings also highlight the need for investigation of possible stronger effects at high nut doses and among diabetic populations. © 2015 American Society for Nutrition.
NASA Astrophysics Data System (ADS)
Lindfors, A. V.; Arola, A.; Kaurola, J.; Taalas, P.; Svenøe, T.
2003-04-01
A method for estimating daily erythemal UV doses using total ozone, sunshine duration and snow depth has been developed. The method consists of three steps: (1) daily clear-sky UV doses were simulated using the UVSPEC radiative transfer program, with daily values of total ozone as input data, (2) an empirical relationship was sought between the simulated clear-sky UV doses, the measured UV doses and the duration of bright sunshine, (3) daily erythemal UV doses were estimated using this relationship. The method accounts for the varying surface albedo by dividing the period of interest into winter and summer days, depending on the snow depth. Using this method, the daily erythemal UV doses at Sodankylä were estimated for the period 1950--99. This was done using Tromsø's total ozone together with Sodankylä's own sunshine duration and snow depth as input data. Although the method is fairly simple, the results are in good agreement, even on the daily scale, with the UV radiation measured with the Brewer spectrophotometer at Sodankylä. Statistically significant increasing trends in erythemal UV doses of a few percents per decade over the period 1950--99 were found for March and April, suggesting a connection to the stratospheric ozone depletion. For July, on the other hand, a significant decreasing trend of about 3% per decade, supported by the changes in both total ozone and sunshine duration, was found. The produced data set of erythemal UV doses is the longest time series of estimated UV known to the authors.
Njeh, Christopher F; Salmon, Howard W; Schiller, Claire
2017-01-01
Intensity-modulated radiation therapy (IMRT) delivery using "step-and-shoot" technique on Varian C-Series linear accelerator (linac) is influenced by the communication frequency between the multileaf collimator and linac controllers. Hence, the dose delivery accuracy is affected by the dose rate. Our aim was to quantify the impact of using two dose rates on plan quality assurance (QA). Twenty IMRT patients were selected for this study. The plan QA was measured at two different dose rates. A gamma analysis was performed, and the degree of plan modulation on the QA pass rate was also evaluated in terms of average monitor unit per segment (MU/segment) and the total number of segments. The mean percentage gamma pass rate of 94.9% and 93.5% for 300 MU/min and 600 MU/min dose rate, respectively, was observed. There was a significant ( P = 0.001) decrease in percentage gamma pass rate when the dose rate was increased from 300 MU/min to 600 MU/min. There was a weak, but significant association between the percentage pass rate at both dose rate and total number of segments. The total number of MU was significantly correlated to the total number of segments ( r = 0.59). We found a positive correlation between the percentage pass rate and mean MU/segment, r = 0.52 and r = 0.57 for 300 MU/min and 600 MU/min, respectively. IMRT delivery using step-and-shoot technique on Varian 2300CD is impacted by the dose rate and the total amount of segments.
Liu, Dongyang; Jiang, Ji; Zhang, Li; Tan, Fenlai; Wang, Yingxiang; Zhang, Don; Hu, Pei
2014-04-01
Icotinib, an oral epidermal growth factor receptor tyrosine kinase inhibitor, has proved effectiveness in xenografted nude mice. Purpose of the present studies was to investigate tolerability and pharmacokinetics of Icotinib in healthy subjects for the first time, including dose proportionality, food effect, and tolerability. Two studies were conducted in total of 22 healthy subjects: a randomized, two-Latin-square crossover, dose proportional study (n = 12) and a randomized two-way crossover food-effect study (n = 10). Plasma concentration of Icotinib reached peak at a median Tmax of 0.75-3.5 h after single dose and then declined with a mean t1/2β of 6.02-7.83 h. Over the dose range of 100-600 mg, AUC values were proportional to dose and Cmax showed a slight saturation when dose increases. Only 0.2 % of the dose was excreted through kidney in unchanged Icotinib. After dosing 400 mg of Icotinib with high-fat and high-calorie meal, mean Cmax and AUC were significantly increased by 59 and 79 %, respectively. Three subjects experienced four adverse events (rash, increase in AST and ALT, and external injury). Rash and increased levels of AST and ALT were considered as drug-related. No serious adverse events were reported. The current work demonstrated that Icotinib was well tolerated in healthy male subjects (n = 22) over the dose range of 100-600 mg with or without food. Icotinib exposure, expressed in AUC, was proportionally increased with dose over the above dose range. Food intake significantly increased the absorption and exposure of Icotinib in healthy subjects.
Confidence Level Based Approach to Total Dose Specification for Spacecraft Electronics
NASA Technical Reports Server (NTRS)
Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; Label, K. A.
2017-01-01
A confidence level based approach to total dose radiation hardness assurance is presented for spacecraft electronics. It is applicable to both ionizing and displacement damage dose. Results are compared to the traditional approach that uses radiation design margin and advantages of the new approach are discussed.
Total Ionizing Dose Effects in Bipolar and BiCMOS Devices
NASA Technical Reports Server (NTRS)
Chavez, Rosa M.; Rax, Bernard G.; Scheick, Leif Z.; Johnston, Allan H.
2005-01-01
This paper describes total ionizing dose (TID) test results performed at JPL. Bipolar and BiCMOS device samples were tested exhibiting significant degradation and failures at different irradiation levels. Linear technology which is susceptible to low-dose dependency (ELDRS) exhibited greater damage for devices tested under zero bias condition.
Schulze, Ralf Kurt Willy; Sazgar, Mahssa; Karle, Heiko; de Las Heras Gala, Hugo
2017-08-01
The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute and relative differences computed. Reproducibility was expressed as the coefficient of variation (CV) between the 10 repeated assessments. The highest doses observed at skin level were found at the thyroid (mean shielded ± SD: 450.5 ± 346.7 μGy; non-shielded: 339.2 ± 348.8 μGy, p = 0.4922). Shielding resulted in a highly significant (p < 0.001) 93% dose reduction in skin dose in the female breast region with a mean non-shielded dose of approximately 35 μGy. Dose reduction was also significantly lower for the back-region (mean: -65%, p < 0.0001) as well as for the gonad-region (mean: -98%, p < 0.0001) in the shielded situation. Reproducibility was inversely correlated to skin dose (Rspearman = -0.748, p < 0.0001) with a mean CV of 10.45% (SD: 24.53 %). Skin dose in the thyroid region of the simulated patient was relatively high and not influenced by the lead apron, which did not shield this region. Dose reduction by means of a commercial lead apron was significant in all other regions, particularly in the region of the female breast.
Alwood, Joshua S.; Tran, Luan H.; Schreurs, Ann-Sofie; Shirazi-Fard, Yasaman; Kumar, Akhilesh; Hilton, Diane; Tahimic, Candice G. T.; Globus, Ruth K.
2017-01-01
Space radiation may pose a risk to skeletal health during subsequent aging. Irradiation acutely stimulates bone remodeling in mice, although the long-term influence of space radiation on bone-forming potential (osteoblastogenesis) and possible adaptive mechanisms are not well understood. We hypothesized that ionizing radiation impairs osteoblastogenesis in an ion-type specific manner, with low doses capable of modulating expression of redox-related genes. 16-weeks old, male, C57BL6/J mice were exposed to low linear-energy-transfer (LET) protons (150 MeV/n) or high-LET 56Fe ions (600 MeV/n) using either low (5 or 10 cGy) or high (50 or 200 cGy) doses at NASA’s Space Radiation Lab. Five weeks or one year after irradiation, tissues were harvested and analyzed by microcomputed tomography for cancellous microarchitecture and cortical geometry. Marrow-derived, adherent cells were grown under osteoblastogenic culture conditions. Cell lysates were analyzed by RT-PCR during the proliferative or mineralizing phase of growth, and differentiation was analyzed by imaging mineralized nodules. As expected, a high dose (200 cGy), but not lower doses, of either 56Fe or protons caused a loss of cancellous bone volume/total volume. Marrow cells produced mineralized nodules ex vivo regardless of radiation type or dose; 56Fe (200 cGy) inhibited osteoblastogenesis by more than 90% (5 weeks and 1 year post-IR). After 5 weeks, irradiation (protons or 56Fe) caused few changes in gene expression levels during osteoblastogenesis, although a high dose 56Fe (200 cGy) increased Catalase and Gadd45. The addition of exogenous superoxide dismutase (SOD) protected marrow-derived osteoprogenitors from the damaging effects of exposure to low-LET (137Cs γ) when irradiated in vitro, but had limited protective effects on high-LET 56Fe-exposed cells. In sum, either protons or 56Fe at a relatively high dose (200 cGy) caused persistent bone loss, whereas only high-LET 56Fe increased redox-related gene expression, albeit to a limited extent, and inhibited osteoblastogenesis. Doses below 50 cGy did not elicit widespread responses in any parameter measured. We conclude that high-LET irradiation at 200 cGy impaired osteoblastogenesis and regulated steady-state gene expression of select redox-related genes during osteoblastogenesis, which may contribute to persistent bone loss. PMID:28994728
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, John M.; Lockman, David; Yan Di
Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volumemore » parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.« less
Wu, Gongqing; Xu, Li; Yi, Yunhong
2016-06-01
Larvae of Galleria mellonella are useful models for studying the innate immunity of invertebrates or for evaluating the virulence of microbial pathogens. In this work, we demonstrated that prior exposure of G. mellonella larvae to high doses (1×10(4), 1×10(5) or 1×10(6) cells/larva) of heat-killed Photorhabdus luminescens TT01 increases the resistance of larvae to a lethal dose (50 cells/larva) of viable P. luminescens TT01 infection administered 48h later. We also found that the changes in immune protection level were highly correlated to the changes in levels of cellular and humoral immune parameters when priming the larvae with different doses of heat-killed P. luminescens TT01. Priming the larvae with high doses of heat-killed P. luminescens TT01 resulted in significant increases in the hemocytes activities of phagocytosis and encapsulation. High doses of heat-killed P. luminescens TT01 also induced an increase in total hemocyte count and a reduction in bacterial density within the larval hemocoel. Quantitative real-time PCR analysis showed that genes coding for cecropin and gallerimycin and galiomycin increased in expression after priming G. mellonella with heat-killed P. luminescens TT01. All the immune parameters changed in a dose-dependent manner. These results indicate that the insect immune system is capable of sensing the extent of priming agent and mounting a proportionate immune response. Copyright © 2016 European Federation of Immunological Societies. Published by Elsevier B.V. All rights reserved.
Gwynn, Justin P; Nalbandyan, Anna; Rudolfsen, Geir
2013-02-01
This paper discusses activity concentrations of (210)Po, (210)Pb, (40)K and (137)Cs in edible wild berries and mushrooms collected from Øvre Dividalen national park, Northern Norway and derives committed effective ingestion doses to man based on high consumption rates of these wild foods. Edible wild berries and mushrooms accumulated similar levels of (210)Pb, but mushrooms accumulated higher levels of (210)Po and (40)K than berries. There appears to be a clear difference in the ability of Leccinum spp. of fungi to accumulate (210)Po and/or translocate (210)Po to mushrooms compared to Russula spp. of fungi. Activity concentrations of (137)Cs in edible wild berries and mushrooms from Øvre Dividalen national park reflected the lower levels of fallout of this radionuclide in Northern Norway compared to more central areas following the Chernobyl accident. For mushrooms, ingestion doses are dominated by (210)Po, while for berries, (40)K is typically the main contributor to dose. Based on high consumption rates, ingestion doses arising from the combination of (210)Po, (210)Pb and (40)K were up to 0.05 mSv/a for berries and 0.50 mSv/a for mushrooms. Consumption of such wild foods may result in a significant contribution to total annual doses when consumed in large quantities, particularly when selecting mushrooms species that accumulate high activity concentrations of (210)Po. Copyright © 2012 Elsevier Ltd. All rights reserved.
[Influence of n-hexane on vascular endothelial active substances in brain tissue in mice].
Lin, L; Zhang, Z Q; Zhang, C Z
2017-01-20
Objective: To investigate the influence of n - hexane on vascular endothelial active substances in brain tissue in mice and its significance. Methods: A total of 48 healthy Kunming mice were randomly divided into high - dose exposure group, middle - dose exposure group, low - dose exposure group, and control group, with 12 mice in each group. All groups except the control group were exposed to n - hexane via static inhalation (0.035 g/L, 0.018 g/L, and 0.009 g/L for the high - , middle - , and low - dose exposure groups, respectively) 4 hours a day for 21 days. the mice in the control groups were not exposed to n - hexane. After the exposure, the lev-els of endothelin - 1 (ET - 1) , nitric oxide (NO) , and angiotensin II (Ang II) in brain tissue were measured in all groups. Results: There were significant differences in the levels of ET - 1, NO, and Ang II between the three ex-posure groups and the control group ( P <0.05). Compared with the control group, the high - and middle - dose expo-sure group had significant increases in the levels of ET - 1 and Ang II and the high - dose exposure group had a sig-nificant reduction in the level of NO ( P <0.05 or P <0.01). Conclusion: n - Hexane can affect the vascular endothe-lial active substances in brain tissue in mice, and the changes and imbalance in vascular endothelial active sub-stances may be one of the reasons for central nervous system impairment caused by n - hexane.
DICOM organ dose does not accurately represent calculated dose in mammography
NASA Astrophysics Data System (ADS)
Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.
2016-03-01
This study aims to analyze the agreement between the mean glandular dose estimated by the mammography unit (organ dose) and mean glandular dose calculated using Dance et al published method (calculated dose). Anonymised digital mammograms from 50 BreastScreen NSW centers were downloaded and exposure information required for the calculation of dose was extracted from the DICOM header along with the organ dose estimated by the system. Data from quality assurance annual tests for the included centers were collected and used to calculate the mean glandular dose for each mammogram. Bland-Altman analysis and a two-tailed paired t-test were used to study the agreement between calculated and organ dose and the significance of any differences. A total of 27,869 dose points from 40 centers were included in the study, mean calculated dose and mean organ dose (+/- standard deviation) were 1.47 (+/-0.66) and 1.38 (+/-0.56) mGy respectively. A statistically significant 0.09 mGy bias (t = 69.25; p<0.0001) with 95% limits of agreement between calculated and organ doses ranging from -0.34 and 0.52 were shown by Bland-Altman analysis, which indicates a small yet highly significant difference between the two means. The use of organ dose for dose audits is done at the risk of over or underestimating the calculated dose, hence, further work is needed to identify the causal agents for differences between organ and calculated doses and to generate a correction factor for organ dose.
Analysis of dose-LET distribution in the human body irradiated by high energy hadrons.
Sato, T; Tsuda, S; Sakamoto, Y; Yamaguchi, Y; Niita, K
2003-01-01
For the purposes of radiological protection, it is important to analyse profiles of the particle field inside a human body irradiated by high energy hadrons, since they can produce a variety of secondary particles which play an important role in the energy deposition process, and characterise their radiation qualities. Therefore Monte Carlo calculations were performed to evaluate dose distributions in terms of the linear energy transfer of ionising particles (dose-LET distribution) using a newly developed particle transport code (Particle and Heavy Ion Transport code System, PHITS) for incidences of neutrons, protons and pions with energies from 100 MeV to 200 GeV. Based on these calculations, it was found that more than 80% and 90% of the total deposition energies are attributed to ionisation by particles with LET below 10 keV microm(-1) for the irradiations of neutrons and the charged particles, respectively.
Fault Tolerant Characteristics of Artificial Neural Network Electronic Hardware
NASA Technical Reports Server (NTRS)
Zee, Frank
1995-01-01
The fault tolerant characteristics of analog-VLSI artificial neural network (with 32 neurons and 532 synapses) chips are studied by exposing them to high energy electrons, high energy protons, and gamma ionizing radiations under biased and unbiased conditions. The biased chips became nonfunctional after receiving a cumulative dose of less than 20 krads, while the unbiased chips only started to show degradation with a cumulative dose of over 100 krads. As the total radiation dose increased, all the components demonstrated graceful degradation. The analog sigmoidal function of the neuron became steeper (increase in gain), current leakage from the synapses progressively shifted the sigmoidal curve, and the digital memory of the synapses and the memory addressing circuits began to gradually fail. From these radiation experiments, we can learn how to modify certain designs of the neural network electronic hardware without using radiation-hardening techniques to increase its reliability and fault tolerance.
Exposure to atmospheric radon.
Steck, D J; Field, R W; Lynch, C F
1999-01-01
We measured radon (222Rn) concentrations in Iowa and Minnesota and found that unusually high annual average radon concentrations occur outdoors in portions of central North America. In some areas, outdoor concentrations exceed the national average indoor radon concentration. The general spatial patterns of outdoor radon and indoor radon are similar to the spatial distribution of radon progeny in the soil. Outdoor radon exposure in this region can be a substantial fraction of an individual's total radon exposure and is highly variable across the population. Estimated lifetime effective dose equivalents for the women participants in a radon-related lung cancer study varied by a factor of two at the median dose, 8 mSv, and ranged up to 60 mSv (6 rem). Failure to include these doses can reduce the statistical power of epidemiologic studies that examine the lung cancer risk associated with residential radon exposure. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:9924007
Yamane, Hiroshi; Takakura, Aya; Shimadzu, Yukari; Kodama, Toshiyuki; Lee, Ji-Won; Isogai, Yukihiro; Ishizuya, Toshinori; Takao-Kawabata, Ryoko
2017-01-01
Teriparatide [human parathyroid hormone (1–34)], which exerts an anabolic effect on bone, is used for the treatment of osteoporosis in patients who are at a high risk for fracture. That the once-daily administration of teriparatide causes an increase in cortical porosity in animal models and clinical studies has been a matter of concern. However, it is not well documented that the frequency of administration and/or the total dose of teriparatide affect the cortical porosity. The present study developed 4 teriparatide regimens [20 μg/kg/day (D20), 40 μg/kg/day (D40), 140 μg/kg/week (W140) and 280 μg/kg/week (W280)] in the rabbit as a model animal with a well-developed Haversian system and osteons. The total weekly doses were equivalent in the low-dose groups (D20 and W140) and in the high-dose groups (D40 and W280). After the short-term (1 month) administration of TPDT, micro-CT, histomorphometry and three-dimensional second harmonic generation (3D-SHG) imaging to visualize the bone collagen demonstrated that daily regimens but not weekly regimens were associated with the significant development of cortical porosity and endosteal naïve bone formation by marrow fibrosis. We concomitantly monitored the pharmacokinetics of the plasma teriparatide levels as well as the temporal changes in markers of bone formation and resorption. The analyses in the present study suggested that the daily repeated administration of teriparatide causes more deleterious changes in the cortical microarchitecture than the less frequent administration of higher doses. The findings of the present study may have some implications for use of teriparatide in clinical treatment. PMID:28394900
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuro, D; Hui, S
Purpose: Totals Marrow Irradiation (TMI) is a highly focused radiation delivery to the human skeleton structure therefore requiring a high amount of precision and accuracy for a quality treatment. Not much is known on how the patient position varies across multiple treatment fractions and how that positioning impacts the dose delivery. Currently TMI is studied as an international collaboration with multiple centers around the world; however, many of these centers used different pretreatment techniques. The goal of this work is to measure the accuracy of patient positioning, its impact on dose delivery and compare the impact of each technique formore » multiple institutions. Methods: Using Tomotherapy pretreatment MVCTs and the planning KVCTs measurements are made of the 3D setup uncertainties of the TMI treatment. Then, using the dose and plan files of the treatment impact of patient position on dose can be measured. Measurement of organ deformation and center of mass change were done using the Velocity AI program from Varian. We are looking at four the boney targets (skull, spine, pelvis, and femur) and three key sensitive tissues (eyes, lungs, kidneys). Results: Position measurements have been made for 3 different institutions using 3 different pre-treatment techniques. Comparing the translation motion we can observe the greatest change in the Y and Z direction of patient set up. For intra-fractional motion the shoulder and clavicle represent the greatest potential for motion and therefore most likely to have a dose change. Conclusion: All centers use different techniques for their treatment and this study shows that these techniques do not produce the same pretreatment results. We hope to expand this study further. Currently we have 3 centers participating in this study with more centers joining every day.« less
Chamberlain, Marc C; Johnston, Sandra K
2010-07-01
We conducted a prospective Phase II study of high-dose methotrexate (HD-MTX) and rituximab with deferred whole brain radiotherapy in patients with newly diagnosed B-cell primary central nervous system lymphoma with a primary objective of evaluating progression-free survival (PFS). Forty patients (25 men; 15 women), ages 18-93 years (median 61.5), were treated. All patients received biweekly HD-MTX/rituximab (8 g/m(2)/dose; 375 mg/m(2)/dose) for 4-6 cycles (induction) and following best radiographic response, with every 4 weeks HD-MTX (8 g/m(2)/dose) for 4 cycles (maintenance). Neurological and neuroradiographic evaluation were performed every 4 weeks during induction therapy and every 8 weeks during maintenance therapy. All patients were evaluable. A total of 303 cycles of HD-MTX (median 8 cycles; range 4-10) was administered. HD-MTX/rituximab-related toxicity included 16 grade 3 adverse events in 13 patients (32.5%). Following induction, 8 patients (20%) demonstrated progressive disease and discontinued therapy; 32 patients (80%) demonstrated a partial (8/40; 20%) or complete (24/40; 60%) radiographic response. At the conclusion of maintenance therapy (6-10 months of total therapy), 28 patients (70%) demonstrated either a partial (1/28) or complete (27/28) response. Overall, survival of these 28 patients ranged from 11 to 80 months (median 33.5). Survival in the entire cohort ranged from 6 to 80 months with an estimated median of 29 months. Overall, PFS ranged from 2 to 80 months (median 21.0). HD-MTX/rituximab and deferred radiotherapy demonstrated similar or better efficacy similar to other HD-MTX-only regimens and reduced time on therapy on average to 6 months.
Chamberlain, Marc C.; Johnston, Sandra K.
2010-01-01
We conducted a prospective Phase II study of high-dose methotrexate (HD-MTX) and rituximab with deferred whole brain radiotherapy in patients with newly diagnosed B-cell primary central nervous system lymphoma with a primary objective of evaluating progression-free survival (PFS). Forty patients (25 men; 15 women), ages 18–93 years (median 61.5), were treated. All patients received biweekly HD-MTX/rituximab (8 g/m2/dose; 375 mg/m2/dose) for 4–6 cycles (induction) and following best radiographic response, with every 4 weeks HD-MTX (8 g/m2/dose) for 4 cycles (maintenance). Neurological and neuroradiographic evaluation were performed every 4 weeks during induction therapy and every 8 weeks during maintenance therapy. All patients were evaluable. A total of 303 cycles of HD-MTX (median 8 cycles; range 4–10) was administered. HD-MTX/rituximab-related toxicity included 16 grade 3 adverse events in 13 patients (32.5%). Following induction, 8 patients (20%) demonstrated progressive disease and discontinued therapy; 32 patients (80%) demonstrated a partial (8/40; 20%) or complete (24/40; 60%) radiographic response. At the conclusion of maintenance therapy (6–10 months of total therapy), 28 patients (70%) demonstrated either a partial (1/28) or complete (27/28) response. Overall, survival of these 28 patients ranged from 11 to 80 months (median 33.5). Survival in the entire cohort ranged from 6 to 80 months with an estimated median of 29 months. Overall, PFS ranged from 2 to 80 months (median 21.0). HD-MTX/rituximab and deferred radiotherapy demonstrated similar or better efficacy similar to other HD-MTX-only regimens and reduced time on therapy on average to 6 months. PMID:20511181
Wu, Yue-Yue; Zha, Ying; Liu, Jun; Wang, Fang; Xu, Jiong; Chen, Zao-Ping; Ding, He-Yuan; Sheng, Li; Han, Xiao-Jie
2016-11-17
To assess the effects of berberine (BBR) on high-molecular weight (HMW) adiponectin and adiponectin receptors (adipoR1/adipoR2) expressions in high-fat (HF) diet fed rats. Forty Wistar male rats were randomly assigned into a normal diet fed group and three HF diet (fat for 45% calories) fed groups (n=10 for each group). All rats underwent 12 weeks of feeding. After 4 weeks feeding, rats in the two of three HF diet fed groups were treated with 150 mg·kg -1 ·day -1 BBR (HF+LBBR group) and 380 mg·kg -1 ·day -1 BBR (HF+HBBR group) by gavage once a day respectively for the next 8 weeks while the rats in other groups treated with vehicle (NF+Veh and HF+Veh). Body weight and food intake were observed and recorded on daily basis. At the end of 12 weeks, the blood, liver, epididymal fat tissues and quadriceps femoris muscles were collected. Fasting insulin, plasma fasting glucose, serum free fatty acid (FFA), total adiponectin and HMW adiponectin levels were measured by enzyme linked immunosorbent assay method. Glucose tolerance test (GTT) and insulin tolerance test (ITT) were performed to determine the insulinsensitizing. Meanwhile the homeostasis model assessment (HOMA) method was used to determine insulin resistance (HOMA-IR). The expressions of adipoR1, adipoR2 and adenosine monophophate activated protein kinase (AMPK) phosphorylation level in skeletal muscle and liver tissue were detected by Western blot. Liver and kidney toxicity were evaluated during treatment. The body weight of rats in high- or low-dose BBR group reduced as well as HOMA-IR, FFA concentrations and fasting insulin levels decreased compared with HF+Veh group (P<0.05). BBR also increased the ratio of HMW to total adiponectin in high fat-fed rats compared with rats in the HF+Veh group. High- and low-dose BBR increased adipoR1 expression in skeletal muscle by over 6- and 2-fold (P<0.05), respectively, and high-dose BBR also increased adipoR2 expression in liver tissue by over 2-fold (P<0.05). BBR significantly increased AMPK phosphorylation in HF diet rats compared with normal diet rats (P<0.05). The ratio of HMW to total adiponectin was inversely correlated with HOMA-IR (r=-0.52, P=0.001). Meantime, no liver and kidney toxicity was found in high fat-fed rats that treated by BBR. Berberine may improve insulin resistance by increasing the expression of adiponectin receptors and the ratio of HMW to total adiponectin.
Jung, Caroline; Greco, Santo; Nguyen, Hanh H T; Ho, Jui T; Lewis, John G; Torpy, David J; Inder, Warrick J
2014-11-26
Glucocorticoid replacement is essential in patients with primary and secondary adrenal insufficiency, but many patients remain on higher than recommended dose regimens. There is no uniformly accepted method to monitor the dose in individual patients. We have compared cortisol concentrations in plasma, saliva and urine achieved following "physiological" and "stress" doses of hydrocortisone as potential methods for monitoring glucocorticoid replacement. Cortisol profiles were measured in plasma, saliva and urine following "physiological" (20 mg oral) or "stress" (50 mg intravenous) doses of hydrocortisone in dexamethasone-suppressed healthy subjects (8 in each group), compared to endogenous cortisol levels (12 subjects). Total plasma cortisol was measured half-hourly, and salivary cortisol and urinary cortisol:creatinine ratio were measured hourly from time 0 (between 0830 and 0900) to 5 h. Endogenous plasma corticosteroid-binding globulin (CBG) levels were measured at time 0 and 5 h, and hourly from time 0 to 5 h following administration of oral or intravenous hydrocortisone. Plasma free cortisol was calculated using Coolens' equation. Plasma, salivary and urine cortisol at 2 h after oral hydrocortisone gave a good indication of peak cortisol concentrations, which were uniformly supraphysiological. Intravenous hydrocortisone administration achieved very high 30 minute cortisol concentrations. Total plasma cortisol correlated significantly with both saliva and urine cortisol after oral and intravenous hydrocortisone (P <0.0001, correlation coefficient between 0.61 and 0.94). There was no difference in CBG levels across the sampling period. An oral dose of hydrocortisone 20 mg is supraphysiological for routine maintenance, while stress doses above 50 mg 6-hourly would rarely be necessary in managing acute illness. Salivary cortisol and urinary cortisol:creatinine ratio may provide useful alternatives to plasma cortisol measurements to monitor replacement doses in hypoadrenal patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vano, Eliseo, E-mail: eliseov@med.ucm.es; Escaned, Javier; Vano-Galvan, Sergio
Complex percutaneous interventions often require high radiation doses likely to produce skin radiation injuries. We assessed the methodology used to select patients with potential skin injuries in cardiac procedures and in need of clinical follow-up. We evaluated peak skin dose and clinical follow-up in a case of radiodermatitis produced during a total occlusion recanalization. This prospective study followed CIRSE and ACC/AHA/SCAI recommendations for patient radiation dose management in interventional procedures carried out in a university hospital with a workload of 4200 interventional cardiac procedures per year. Patient dose reports were automatically transferred to a central database. Patients exceeding trigger levelsmore » for air kerma area product (500 Gy cm{sup 2}) and cumulative skin dose (5 Gy) were counseled and underwent follow-up for early detection of skin injuries, with dermatologic support. The Ethical Committee and the Quality Assurance and Radiation Safety Committee approved the program. During 2010, a total of 13 patients (3.0/1,000 that year) received dose values exceeding trigger levels in the cardiovascular institute. Only one patient, who had undergone two consecutive procedures resulting in 970 Gy cm{sup 2} and 13.0 Gy as cumulative skin dose, showed signs of serious radiodermatitis that resolved in 3.7 months. The remaining patients did not manifest skin lesions during follow-up, and whenever patient examination was not feasible as part of the follow-up, neither patients nor families reported any skin injuries. Peak skin dose calculation and close clinical follow-up were feasible and appropriate, with a moderate additional workload for the staff and satisfaction for the patient.« less
High-dose phenobarbital or erythropoietin for the treatment of perinatal asphyxia in term newborns.
Avasiloaiei, Andreea; Dimitriu, Cristina; Moscalu, Mihaela; Paduraru, Luminita; Stamatin, Maria
2013-10-01
The aim of this study was to compare two neuroprotective strategies to supportive care in the treatment of perinatal asphyxia. A total of 67 term newborns with perinatal asphyxia were included and randomized into three groups: one group received supportive treatment; another group received a single dose of 40 mg/kg phenobarbital; and the third received three daily doses of 1000 IU/kg erythropoietin. The following parameters were analyzed: gestational age, birthweight, Apgar scores, cord blood pH, total serum antioxidant status (TAS), superoxide dismutase (SOD), glutathione peroxidase (GPx) and malondialdehyde (MDA). The newborns were included in the follow-up program and examined up to 18 months of age. TAS was higher in the erythropoietin group than in the other groups. SOD and GPx were lower for infants treated with phenobarbital or erythropoietin compared to control infants. MDA was lower in the erythropoietin group compared to the other groups, although the difference was not statistically significant (P > 0.05). The mortality rate was lower in the phenobarbital and erythropoietin groups (both 4.6%) than in the control group (17.4%). Long-term neurologic follow up showed a high incidence of sequelae in the control group compared to the phenobarbital and erythropoietin groups. Follow-up results were better in the phenobarbital group than in the erythropoietin group for motor and cognitive function at 3 and 6 months and worse for expressive language. At 18 months, however, the differences between these two groups were not significant. High-dose phenobarbital or erythropoietin along with supportive treatment has a positive influence on the outcome of newborns with perinatal asphyxia. Phenobarbital has the advantage of low cost and simplicity. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.
Meldrum, Suzanne J; D'Vaz, Nina; Simmer, Karen; Dunstan, Janet A; Hird, Kathryn; Prescott, Susan L
2012-10-28
n-3 Long-chain PUFA (LC-PUFA) intake during infancy is important for neurodevelopment; however, previous studies of n-3 LC-PUFA supplementation have been inconclusive possibly due to an insufficient dose and limited methods of assessment. The present study aimed to evaluate the effects of direct supplementation with high-dose fish oil (FO) on infant neurodevelopmental outcomes and language. In the present randomised, double-blind, placebo-controlled trial, 420 healthy term infants were assigned to receive a DHA-enriched FO supplement (containing at least 250 mg DHA/d and 60 mg EPA/d) or a placebo (olive oil) from birth to 6 months. Assessment occurred at 18 months via the Bayley Scales of Infant and Toddler Development (3rd edition; BSID-III) and the Child Behavior Checklist. Language assessment occurred at 12 and 18 months via the Macarthur-Bates Communicative Development Inventory. The FO group had significantly higher erythrocyte DHA (P = 0·03) and plasma phospholipid DHA (P = 0·01) levels at 6 months of age relative to placebo. In a small subset analysis (about 40% of the total population), children in the FO group had significantly higher percentile ranks of both later developing gestures at 12 and 18 months (P = 0·007; P = 0·002, respectively) and the total number of gestures (P = 0·023; P = 0·006, respectively). There was no significant difference between the groups in the standard or composite scores of the BSID-III. The results suggest that improved postnatal n-3 LC-PUFA intake in the first 6 months of life using high-dose infant FO supplementation was not beneficial to global infant neurodevelopment. However, some indication of benefits to early communicative development was observed.
Yue, Chen; Wei, Rong; Liu, Youwen
2017-06-27
Perioperative systemic steroid administration for rapid recovery in total knee and hip arthroplasty (TKA/THA) is an important and controversial topic. We conducted this systematic review and meta-analysis to evaluate the overall benefits and harms of perioperative systemic steroid in patients undergoing TKA and THA. A comprehensive search was performed on PubMed, OVID, and Web of Science databases, and a systematic approach was carried out starting from the PRISMA recommendations. Relevant randomized controlled trials (RCTs) were selected. The risk of bias was evaluated according to the Cochrane Handbook for Systematic Reviews of Interventions version. Data were extracted and meta-analyzed or qualitatively synthesized for all the outcomes. Data were extracted from 11 trials involving 774 procedures. Meta-analysis showed that high-dose systemic steroid (dexamethasone > 0.1 mg/kg) rather than low dose is effective to reduce postoperative nausea and vomiting and postoperative acute pain (within 24 h). In addition, systemic steroid is associated within faster functional rehabilitation and greater inflammation control. On the other hand, systemic steroid is associated with a higher level of postoperative serum glucose on the operation day. The complications between groups are similarly low. Our study suggests that by providing lower incidence of postoperative nausea and vomiting and less postoperative acute pain, high-dose systemic steroid plays a critical role in rapid recovery to TKA and THA. The preliminary results also show the superior possibility of systemic steroid in functional rehabilitation and inflammation control. More large, high-quality studies that investigate the safety and dose-response relationship are necessary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rimner, Andreas; Lovie, Shona; Hsu, Meier
Purpose: We report the long-term results of integrated accelerated involved field radiation therapy (IFRT) followed by total lymphoid irradiation (TLI) as part of the high-dose salvage regimen followed by autologous bone marrow transplantation or autologous stem cell transplantation in patients with relapsed or refractory Hodgkin lymphoma (HL). Methods and Materials: From November 1985 to July 2008, 186 previously unirradiated patients with relapsed or refractory HL underwent salvage therapy on 4 consecutive institutional review board–approved protocols. All patients had biopsy-proven primary refractory or relapsed HL. After standard-dose salvage chemotherapy (SC), accelerated IFRT (18-20 Gy) was given to relapsed or refractory sites, followedmore » by TLI (15-18 Gy) and high-dose chemotherapy. Overall survival (OS) and event-free survival (EFS) were analyzed by Cox analysis and disease-specific survival (DSS) by competing-risk regression. Results: With a median follow-up period of 57 months among survivors, 5- and 10-year OS rates were 68% and 56%, respectively; 5- and 10-year EFS rates were 62% and 56%, respectively; and 5- and 10-year cumulative incidences of HL-related deaths were 21% and 29%, respectively. On multivariate analysis, complete response to SC was independently associated with improved OS and EFS. Primary refractory disease and extranodal disease were independently associated with poor DSS. Eight patients had grade 3 or higher cardiac toxicity, with 3 deaths. Second malignancies developed in 10 patients, 5 of whom died. Conclusions: Accelerated IFRT followed by TLI and high-dose chemotherapy is an effective, feasible, and safe salvage strategy for patients with relapsed or refractory HL with excellent long-term OS, EFS, and DSS. Complete response to SC is the most important prognostic factor.« less
Radiation exposure from diagnostic imaging in young patients with testicular cancer.
Sullivan, C J; Murphy, K P; McLaughlin, P D; Twomey, M; O'Regan, K N; Power, D G; Maher, M M; O'Connor, O J
2015-04-01
Risks associated with high cumulative effective dose (CED) from radiation are greater when imaging is performed on younger patients. Testicular cancer affects young patients and has a good prognosis. Regular imaging is standard for follow-up. This study quantifies CED from diagnostic imaging in these patients. Radiological imaging of patients aged 18-39 years, diagnosed with testicular cancer between 2001 and 2011 in two tertiary care centres was examined. Age at diagnosis, cancer type, dose-length product (DLP), imaging type, and frequency were recorded. CED was calculated from DLP using conversion factors. Statistical analysis was performed with SPSS. In total, 120 patients with a mean age of 30.7 ± 5.2 years at diagnosis had 1,410 radiological investigations. Median (IQR) surveillance was 4.37 years (2.0-5.5). Median (IQR) CED was 125.1 mSv (81.3-177.5). Computed tomography accounted for 65.3 % of imaging studies and 98.3 % of CED. We found that 77.5 % (93/120) of patients received high CED (>75 mSv). Surveillance time was associated with high CED (OR 2.1, CI 1.5-2.8). Survivors of testicular cancer frequently receive high CED from diagnostic imaging, mainly CT. Dose management software for accurate real-time monitoring of CED and low-dose CT protocols with maintained image quality should be used by specialist centres for surveillance imaging. • CT accounted for 98.3 % of CED in patients with testicular cancer. • Median CED in patients with testicular cancer was 125.1 mSv • High CED (>75 mSv) was observed in 77.5 % (93/120) of patients. • Dose tracking and development of low-dose CT protocols are recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niedbala, M; Save, C; Cygler, J
Purpose: To evaluate the feasibility of using optically stimulated luminescence dosimeters (OSLDs) for in-vivo dosimetry of patients undergoing Total Body and Total Marrow Irradiations (TBI and TMI). Methods: TBI treatments of 12 Gy were delivered in 6 BID fractions with the patient on a moving couch under a static 10 MV beam (Synergy, Elekta). TMI treatments of 18 Gy in 9 BID fractions were planned and delivered using a 6 MV TomoTherapy unit (Accuray). To provide a uniform dose to the entire patient length, the treatment was split into 2 adjacent fields junctioned in the thigh region. Our standard clinicalmore » practice involves in vivo dosimetry with MOSFETs for each TBI fraction and TLDs for at least one fraction of the TMI treatment for dose verification. In this study we also used OSLDs. Individual calibration coefficients were obtained for the OSLDs based on irradiations in a solid water phantom to the dose of 50 cGy from Elekta Synergy 10 MV (TBI) and 6 MV (TMI) beams. Calibration coefficients were calculated based on the OSLDs readings taken 2 hrs post-irradiation. For in vivo dosimetry OSLDs were placed alongside MOSFETs for TBI patients and in approximately the same locations as the TLDs for TMI patients. OSLDs were read 2 hours post treatment and compared to the MOSFET and TLD results. Results: OSLD measured doses agreed within 5% with MOSFET and TLD results, with the exception of the junction region in the TMI patient due to very high dose gradient and difficulty of precise and reproducible detector placement. Conclusion: OSLDs are useful for in vivo dosimetry of TBI and TMI patients. The quick post-treatment readout is an advantage over TLDs, allowing the results to be obtained between BID fractions, while wireless detectors are advantageous over MOSFETs for treatments involving a moving couch.« less
NASA Astrophysics Data System (ADS)
Hernawati; Setiawan, N. A.; Shintawati, R.; Priyandoko, D.
2018-05-01
The purpose of this research was to know the role of red dragon fruit peel powder to total cholesterol, triglyceride, high-density lipoprotein (HDL), low-density lipoprotein (LDL), and weight in the male hyperlipidaemic Balb-C mice (Mus musculus). This study used a completely randomized design (CRD) and four replicates for each dose treatments. Samples were 24 male mice that divided into six groups i.e. positive and negative controls, doses of 50; 100; 150 and 200 mg/kgBW/days red dragon fruit peel powder. Before being given treatment, mice were given feed containing high fat for 20 days until experiencing conditions hyperlipidaemia. The red dragon fruit peel powder was given at oral with used gavage for 30 days. Blood samples were taken from the tail on vena caudalis. Blood lipid samples were analysed at enzymatic with BIOLABO kits. The results of this study indicate that after administration of red dragon fruit peel powder total cholesterol levels, triglycerides and LDL-c decreased, along with increasing doses of red dragon fruit peel powder for 30 days. Furthermore showed that dragon fruit powder can increase HDL-c levels. The conclusion of this research was The red dragon fruit peel powder can improve blood lipid level of male Balb-c mice hyperlipidaemia.
Benefits of online in vivo dosimetry for single-fraction total body irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eaton, David J., E-mail: davideaton@nhs.net; Warry, Alison J.; Trimble, Rachel E.
Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013,more » with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.« less
NASA Astrophysics Data System (ADS)
Hajdas, Wojtek; Mrigakshi, Alankrita; Xiao, Hualin
2017-04-01
The primary concern of the ESA JUICE mission to Jupiter is the harsh particle radiation environment. Ionizing particles introduce radiation damage by total dose effects, displacement damages or single events effects. Therefore, both the total ionizing dose and the displacement damage equivalent fluence must be assessed to alert spacecraft and its payload as well as to quantify radiation levels for the entire mission lifetime. We present a concept and implementations steps for simplified method used to compute in flight a dose rate and total dose caused by protons. We also provide refinement of the method previously developed for electrons. The dose rates values are given for predefined active volumes located behind layers of materials with known thickness. Both methods are based on the electron and proton flux measurements provided by the Electron and Proton Detectors inside the Radiation Hard Electron Monitor (RADEM) located on-board of JUICE. The trade-off between method accuracy and programming limitations for in-flight computations are discussed. More comprehensive and precise dose rate computations based on detailed analysis of all stack detectors will be made during off-line data processing. It will utilize full spectral unfolding from all RADEM detector subsystems.
[Clinical experience of carbon ion radiotherapy for malignant tumors].
Ishikawa, Hitoshi; Tsuji, Hiroshi; Tsujii, Hirohiko
2006-04-01
The carbon ion (C-ion) beams provide unique advantageous biological and physical properties in radiotherapy (RT) for malignant tumors. C-ion beams have a high relative biological effectiveness (RBE) resulting from the high linear energy transfer (LET). In terms of their physical characteristics, C-ion beams exhibit a spread-out Bragg peak (SOBP) and make for a better dose distribution of the target volume by specified beam modulations. Between June 1994 and August 2005, a total of 2,371 patients with malignant tumors were registered in phase I/II dose-escalation studies and clinical phase II trials using C-ion beams generated at Heavy Ion Medical Accelerator in Chiba (HIMAC). In the initial dose-escalation studies, grade 3 or more late rectal complications had developed in some patients. However, the adverse effects were resolved because of the use of appropriate dose levels and modification of the radiation technique. C-ion beams can carry out hypofractionated radiotherapy with a large fraction dose and reduce the overall treatment times compared with conventional radiotherapy. They can also achieve better local tumor control even for radio-resistant tumors such as malignant melanoma, hepatocellular carcinoma and bone and soft tissue sarcomas with minimal morbidity to the normal surrounding tissues.
Guo, Jing; Astrup, Arne; Lovegrove, Julie A; Gijsbers, Lieke; Givens, David I; Soedamah-Muthu, Sabita S
2017-04-01
With a growing number of prospective cohort studies, an updated dose-response meta-analysis of milk and dairy products with all-cause mortality, coronary heart disease (CHD) or cardiovascular disease (CVD) have been conducted. PubMed, Embase and Scopus were searched for articles published up to September 2016. Random-effect meta-analyses with summarised dose-response data were performed for total (high-fat/low-fat) dairy, milk, fermented dairy, cheese and yogurt. Non-linear associations were investigated using the spine models and heterogeneity by subgroup analyses. A total of 29 cohort studies were available for meta-analysis, with 938,465 participants and 93,158 mortality, 28,419 CHD and 25,416 CVD cases. No associations were found for total (high-fat/low-fat) dairy, and milk with the health outcomes of mortality, CHD or CVD. Inverse associations were found between total fermented dairy (included sour milk products, cheese or yogurt; per 20 g/day) with mortality (RR 0.98, 95% CI 0.97-0.99; I 2 = 94.4%) and CVD risk (RR 0.98, 95% CI 0.97-0.99; I 2 = 87.5%). Further analyses of individual fermented dairy of cheese and yogurt showed cheese to have a 2% lower risk of CVD (RR 0.98, 95% CI 0.95-1.00; I 2 = 82.6%) per 10 g/day, but not yogurt. All of these marginally inverse associations of totally fermented dairy and cheese were attenuated in sensitivity analyses by removing one large Swedish study. This meta-analysis combining data from 29 prospective cohort studies demonstrated neutral associations between dairy products and cardiovascular and all-cause mortality. For future studies it is important to investigate in more detail how dairy products can be replaced by other foods.
Image-guided total marrow and total lymphatic irradiation using helical tomotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultheiss, Timothy E.; Wong, Jeffrey; Liu, An
2007-03-15
Purpose: To develop a treatment technique to spare normal tissue and allow dose escalation in total body irradiation (TBI). We have developed intensity-modulated radiotherapy techniques for the total marrow irradiation (TMI), total lymphatic irradiation, or total bone marrow plus lymphatic irradiation using helical tomotherapy. Methods and Materials: For TBI, we typically use 12 Gy in 10 fractions delivered at an extended source-to-surface distance (SSD). Using helical tomotherapy, it is possible to deliver equally effective doses to the bone marrow and lymphatics while sparing normal organs to a significant degree. In the TMI patients, whole body skeletal bone, including the ribsmore » and sternum, comprise the treatment target. In the total lymphatic irradiation, the target is expanded to include the spleen and major lymph node areas. Sanctuary sites for disease (brain and testes) are included when clinically indicated. Spared organs include the lungs, esophagus, parotid glands, eyes, oral cavity, liver, kidneys, stomach, small and large intestine, bladder, and ovaries. Results: With TBI, all normal organs received the TBI dose; with TMI, total lymphatic irradiation, and total bone marrow plus lymphatic irradiation, the visceral organs are spared. For the first 6 patients treated with TMI, the median dose to organs at risk averaged 51% lower than would be achieved with TBI. By putting greater weight on the avoidance of specific organs, greater sparing was possible. Conclusion: Sparing of normal tissues and dose escalation is possible using helical tomotherapy. Late effects such as radiation pneumonitis, veno-occlusive disease, cataracts, neurocognitive effects, and the development of second tumors should be diminished in severity and frequency according to the dose reduction realized for the organs at risk.« less
Abdel Aziz, Rabie L; Abdel-Wahab, Ahmed; Abo El-Ela, Fatma I; Hassan, Nour El-Houda Y; El-Nahass, El-Shaymaa; Ibrahim, Marwa A; Khalil, Abdel-Tawab A Y
2018-06-01
This study aimed to determine the protective effects of co-administration of Quercetin (QT) or l-Carnitine (LC) against the oxidative stress induced by Atrazine (ATZ) in the reproductive system of intact male Albino rats. 36 rats were divided equally into 6 groups. Rats in the control negative "CNT" group received 1.5 ml distilled water for 21 days. All rats in the other groups received ATZ (120 mg/kg bw) through gavage. Groups 3 and 4 were co-administered with either low or high dose of QT (10 "ATZLQT" and 50 "ATZHQT" mg/kg bw, respectively). Groups 5 and 6 were co-administered with either low or high dose of LC (200 "ATZLLC" and 400 "ATZHLC" mg/kg bw, respectively). At the end of the experiment, animals were sacrificed and all samples were collected. ATZ significantly increased serum level of malondialdehyde (MDA) and decreased total antioxidant capacity (TAC). Also, ATZ increased significantly the sperm cell abnormalities and reduced both testicular IgA and serum testosterone levels. Testicular DNA laddering % and CYP17A1 mRNA expression were significantly reduced in ATZ group. Interestingly, co-administration with low dose QT or different doses of LC succeeded to counteract the negative toxic effects of ATZ on serum oxidative stress indicators, serum testosterone levels, testicular IgA level and improved testicular CYP17A1 mRNA expression. In conclusion, QT in low dose and LC in both low and high doses exerted a significant protective action against the reproductive toxicity of ATZ, while higher dose of QT failed induce immune-stimulant effect against ATZ in adult male Albino rats. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
A novel acenocoumarol pharmacogenomic dosing algorithm for the Greek population of EU-PACT trial.
Ragia, Georgia; Kolovou, Vana; Kolovou, Genovefa; Konstantinides, Stavros; Maltezos, Efstratios; Tavridou, Anna; Tziakas, Dimitrios; Maitland-van der Zee, Anke H; Manolopoulos, Vangelis G
2017-01-01
To generate and validate a pharmacogenomic-guided (PG) dosing algorithm for acenocoumarol in the Greek population. To compare its performance with other PG algorithms developed for the Greek population. A total of 140 Greek patients participants of the EU-PACT trial for acenocoumarol, a randomized clinical trial that prospectively compared the effect of a PG dosing algorithm with a clinical dosing algorithm on the percentage of time within INR therapeutic range, who reached acenocoumarol stable dose were included in the study. CYP2C9 and VKORC1 genotypes, age and weight affected acenocoumarol dose and predicted 53.9% of its variability. EU-PACT PG algorithm overestimated acenocoumarol dose across all different CYP2C9/VKORC1 functional phenotype bins (predicted dose vs stable dose in normal responders 2.31 vs 2.00 mg/day, p = 0.028, in sensitive responders 1.72 vs 1.50 mg/day, p = 0.003, in highly sensitive responders 1.39 vs 1.00 mg/day, p = 0.029). The PG algorithm previously developed for the Greek population overestimated the dose in normal responders (2.51 vs 2.00 mg/day, p < 0.001). Ethnic-specific dosing algorithm is suggested for better prediction of acenocoumarol dosage requirements in patients of Greek origin.
Evaluation of total-dose iron sucrose infusions in patients with iron deficiency anemia.
Wall, Geoffrey C; Pauly, Rebecca A
2008-01-15
The safety and efficacy of a total-dose iron sucrose infusion protocol used in a large, tertiary care teaching hospital were studied. Nondialysis-dependent patients ages 18 years or older who received > or =250 mg of iron sucrose as a single i.v. infusion between January 2005 and January 2007 were eligible for study inclusion. The protocol for total-dose iron sucrose infusion was the same for all patients. The total dose of iron sucrose for each patient was calculated using an equation that included the desired hemoglobin (Hb) value, observed Hb level, ideal body weight, and sex. The calculated dose was divided into portions, rounded to the nearest 250 mg, and administered over four hours every other day. Outcomes measured included Hb, transferrin saturation, and serum ferritin values. A total of 26 patients met the inclusion criteria. The mean +/- S.D. Hb concentration before total-dose iron sucrose infusion was 9.37 +/- 0.9 g/dL, and the mean +/- S.D. corpuscular volume was 75 +/- 7.1 mum(3). The mean +/- S.D. postinfusion Hb concentration for 19 patients for whom follow-up Hb levels were available was 11.4 +/- 1.2 g/dL, significantly higher than the 9.45 +/- 0.8 g/dL measured before the first infusion (p = 0.03). No significant adverse effects were reported in 47 of 49 infusions, with 2 patients experiencing mild nausea. A treatment protocol consisting of alternate-day total-dose iron sucrose infusions was well tolerated and appeared to be effective in improving Hb concentrations in patients with iron deficiency anemia and without chronic kidney disease.
Weaver, R D; Gerbi, B J; Dusenbery, K E
1995-09-30
To determine acceptable dose variation using thermoluminescent dosimeters (TLD) in the treatment of Mycosis Fungoides with total skin electron beam (TSEB) irradiation. From 1983 to 1993, 22 patients were treated with total skin electron beam therapy in the standing position. A six-field technique was used to deliver 2 Gy in two days, treating 4 days per week, to a total dose of 35 to 40 Gy using a degraded 9 MeV electron beam. Thermoluminescent dosimeters were placed on several locations of the body and the results recorded. The variations in these readings were analyzed to determine normal dose variation for various body locations during TSEB. The dose to flat surfaces of the body was essentially the same as the dose to the prescription point. The dose to tangential surfaces was within +/- 10% of the prescription dose, but the readings showed much more variation (up to 24%). Thin areas of the body showed large deviations from the prescription dose along with a large amount of variation in the readings (up to 22%). Special areas of the body, such as the perineum and eyelid, showed large deviations from the prescription dose with very large (up to 40%) variations in the readings. The TLD results of this study will be used as a quality assurance check for all new patients treated with TSEB. The results of the TLDs will be compared with this baseline study to determine if the delivered dose is within acceptable ranges. If the TLD results fall outside the acceptable limits established above, then the patient position can be modified or the technique itself evaluated.
Diuretic downsides--but in low doses they still seem among the best authenticated antihypertensives.
Opie, L H
2000-08-01
Diuretics in low doses have the greatest support among current available antihypertensives in that they have been shown to reduce total mortality, coronary mortality, stroke, and congestive heart failure in an important meta-analysis by Psaty. Recently, Messerli has linked longterm diuretic use to renal cell carcinoma in women. In some patients, diuretic use leads to increasing blood cholesterol and blood sugar levels. Impotence is a recognized side effect, with rates rising about twofold with low-dose chlorthalidone and fourfold with a higher dose. Certain population groups such as younger (<60 years) white males often do not respond to low-dose diuretic therapy with an adequate blood pressure fall. In females of a similar age group, Messerli calculates that prolonged diuretic therapy will prevent only one stroke and no coronary events nor any deaths for every renal cell carcinoma that is provoked. Despite these evident problems, the outcome data on hard endpoints in trials with initial low-dose diuretic therapy remain valid and convincing. Thus, it is argued, low- but not high-dose diuretics retain their primacy in the ranking of antihypertensive therapy.
Radiological dose in Muria peninsula from SB-LOCA event
NASA Astrophysics Data System (ADS)
Sunarko; Suud, Zaki
2017-01-01
Dose assessment for accident condition is performed for Muria Peninsula region using source-term from Three-Mile Island unit 2 SB-LOCA accident. Xe-133, Kr-88, 1-131 and Cs-137 isotopes are considered in the calculation. The effluent is assumed to be released from a 50 m stack. Lagrangian particle dispersion method (LPDM) employing non-Gaussian dispersion coefficient in 3-dimensional mass-consistent wind-field is employed to obtain periodic surface-level concentration which is then time-integrated to obtain spatial distribution of ground-level dose. In 1-hour simulation, segmented plumes with 60 seconds duration with a total of 18.000 particles involved. Simulations using 6-hour worst-case meteorological data from Muria peninsula results in a peak external dose of around 1.668 mSv for low scenario and 6.892 mSv for high scenario in dry condition. In wet condition with 5 mm/hour and 10 mm/hour rain for the whole duration of the simulation provides only minor effect to dose. The peak external dose is below the regulatory limit of 50 mSv for effective skin dose from external gamma exposure.
Liu, Y-J; Song, G-H; Liu, G T
2016-08-01
According to traditional Chinese medicine, the symptoms of chronic nonbacterial prostatitis/chronic pelvic pain syndrome (CNP/CPPS) may be treated using a cocktail of herbs that stimulate blood circulation ('activating blood circulation formula'). We investigated the effect of three doses of this formula on a rat model of CNP/CPPS. Male Wistar rats were injected with a saline extract of male sex accessory glands on days 0 and 30 to induce prostatitis and then treated daily by gavage between days 32 and 60. Treatment with low, medium and high doses of activating blood circulation formula resulted in an almost total rescue of paw withdrawal threshold at day 60, and treatment with the highest dose also significantly decreased prostate inflammation (assessed histopathologically). We further observed elevated serum prostaglandin E2 levels in the CNP/CPPS model which decreased upon high-dose treatment, and increased Cox-2 expression in the prostate and spinal cord dorsal horn which was rescued in both tissues in the high-dose group and in the prostate in the medium-dose group. These results shed light on a possible mechanism by which activating blood circulation therapy may alleviate pain in a rat model of CNP/CPPS by downregulating Cox-2 expression in the spinal cord, thereby raising the pain threshold. Further research will be needed to fully characterise the mechanism by which activating blood circulation therapy produces this therapeutic effect. © 2016 Blackwell Verlag GmbH.
Toxic effects of Tripterygium wilfordii Hook F on the reproductive system of adolescent male rats.
Jing, Xiaoping; Cheng, Weiwei; Guo, Sheng; Zou, Ya; Zhang, Ting; He, Li
2017-11-01
Tripterygium wilfordii Hook F. (TWHF) is a compound extracted from Lei Gong Teng (Thunder God Vine) that has been used to treat a variety of immune-related diseases in clinical practice, particularly in pediatrics. Nevertheless, clinical data indicated that glycosides from Tripterygium wilfordii Hook F (GTW) are toxic to the male reproductive system, but the mechanism is unknown. Here, the administration of a high dose of GTW for 4 weeks and a low dose for 12 weeks can reduce the body weights and testes weights in adolescent male rats. This effect is accompanied by a significantly reduction in the serum testosterone levels. Notably, short-term use of high-dose GTW or long-term use of low-dose GTW leads to testicular damage in adolescent male rats. Furthermore, the expression of the steroidogenic acute regulatory protein (StAR), P450 side chain cleavage enzyme (P450scc), cytochrome P450 17-hydroxylase (P450c17), 3β-hydroxysteroid dehydrogenase (3β-HSD), and 17β-hydroxysteroid dehydrogenase (17β-HSD) mRNAs and proteins in the testes was down-regulated by a short-term treatment with high-dose GTW and a long-term treatment with low-dose GTW. Therefore, GTW exhibit male reproductive toxicity in a concentration-and time-dependent manner by inhibiting the expression of the key enzymes and total cholesterol level involved in testosterone synthesis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Huang, Wenrong; Zhao, Xiaoli; Tian, Yamin; Cao, Tingting; Li, Yanfen; Liu, Zhanxiang; Jing, Yu; Wang, Shuhong; Gao, Chunji; Yu, Li
2015-02-01
Although antithymocyte globulin (ATG) had been widely used in hematopoietic stem cell transplantation from unrelated donor due to its ability to prevent acute and chronic graft-versus-host disease (GVHD), the comparative efficacy and safety of ATG-Thymoglobulin (ATG-T) and ATG-Fresenius (ATG-F) in patients undergoing HLA-mismatched allogeneic peripheral blood stem cell transplantation from unrelated donors (UR-PBSCT) has not been evaluated. Retrospective analysis of patients who underwent HLA-mismatched UR-PBSCT between January 2003 and December 2013 and received pre-transplant ATG-T at a total dose of 10 mg/kg or ATG-F at a total dose of 20 mg/kg was performed. Patients who received ATG-T (n = 23) or ATG-F (n = 28) had similar baseline demographic, disease, and transplant characteristics. There were no significant between-groups differences in the probability of acute GVHD (P = 0.721) and chronic GVHD (P = 0.439). ATG-F was associated with nonsignificant trends toward higher disease-free survival at 3-year follow-up compared with ATG-T (45.7 ± 11.1 vs 61.3 ± 9.7 %, respectively, P = 0.07). A significantly greater proportion of ATG-T patients experienced high fever than ATG-F patients (P < 0.01) during ATG infusion. There was no difference in the rate of infection between the two treatment groups. There were less adverse effects comparing ATG-F with ATG-T. ATG-T at a total dose of 10 mg/kg and ATG-F at a total dose of 20 mg/kg had a similar clinical outcome in the setting of HLA-mismatched UR-PBSCT.
Outbreak of mumps in a school setting, United Kingdom, 2013.
Aasheim, Erlend T; Inns, Thomas; Trindall, Amy; Emmett, Lynsey; Brown, Kevin E; Williams, Chris J; Reacher, Mark
2014-01-01
Effective protection against mumps can be achieved through 2 doses of the measles-mumps-rubella (MMR) vaccine. However, outbreaks of mumps have recently been described among populations with high vaccination coverage, including 2 doses of MMR. Here we describe an outbreak at a school in the East of England, UK. The school was attended by 540 pupils aged 10-19 years and had 170 staff. In total, 28 cases of mumps (24 pupils and 4 staff) were identified during 10 January to 16 March 2013. Vaccination status was known in 25 of the cases, and among these 21 (84.0%) had a documented history of 2 doses of MMR while the remaining had a history of one dose (2/25 cases, 8.0%) or no doses (2/25, 8.0%) of MMR. An outbreak control team recommended that MMR vaccine should be offered to all pupils whose parents consented to it, regardless of previous vaccination status. Additional MMR vaccines were administered to 103 pupils, including 76 (73.8%) third doses of MMR. Offering an additional dose of MMR appeared to be acceptable to parents, and we found it feasible to administer the intervention in a timely manner with resources from the local Public Health Centre (Primary Care Trust). An additional dose of MMR to all individuals at risk can be considered as an acceptable control measure for mumps outbreaks in schools even if the vaccination coverage is high. However, further evidence on the effectiveness, acceptability, and safety of this intervention is needed.
Cosmic radiation dose in aircraft--a neutron track etch detector.
Vuković, B; Radolić, V; Miklavcić, I; Poje, M; Varga, M; Planinić, J
2007-01-01
Cosmic radiation bombards us at high altitude by ionizing particles. The radiation environment is a complex mixture of charged particles of solar and galactic origin, as well as of secondary particles produced in interaction of the galactic cosmic particles with the nuclei of atmosphere of the Earth. The radiation field at aircraft altitude consists of different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard ATR 42 and A 320 aircrafts (flight level of 8 and 11 km, respectively) was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter. The estimated occupational effective dose for the aircraft crew (A 320) working 500 h per year was 1.64 mSv. Other experiments, or dose rate measurements with the neutron dosimeter, consisting of LR-115 track detector and boron foil BN-1 or 10B converter, were performed on five intercontinental flights. Comparison of the dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level showed that the neutron component carried about 50% of the total dose. The dose rate measurements on the flights from the Middle Europe to the South and Middle America, then to Korea and Japan, showed that the flights over or near the equator region carried less dose rate; this was in accordance with the known geomagnetic latitude effect.
Kim, Tae Hyun; Park, Joong-Won; Kim, Yeon-Joo; Kim, Bo Hyun; Woo, Sang Myung; Moon, Sung Ho; Kim, Sang Soo; Lee, Woo Jin; Kim, Dae Yong; Kim, Chang-Min
2014-10-01
The aim of this work was to evaluate the clinical efficacy and safety of simultaneous integrated boost-intensity modulated radiation therapy (SIB-IMRT) in patients with inoperable hepatocellular carcinoma (HCC). A total of 53 patients with inoperable HCC underwent SIB-IMRT using two dose-fractionation schemes, depending on the proximity of gastrointestinal structures. The 41 patients in the low dose-fractionation (LD) group, with internal target volume (ITV) < 1 cm from gastrointestinal structures, received total doses of 55 and 44 Gy in 22 fractions to planning target volume 1 (PTV1) and 2 (PTV2), respectively. The 12 patients in the high dose-fractionation (HD) group, with ITV ≥ 1 cm from gastrointestinal structures, received total doses of 66 and 55 Gy in 22 fractions to the PTV1 and PTV2, respectively. Overall, treatment was well tolerated, with no grade > 3 toxicity. The LD group had larger sized tumors (median: 6 vs. 3.4 cm) and greater frequencies of vascular invasion (80.6 vs. 16.7 %) than patients in the HD group (p < 0.05 each). The median overall survival (OS) was 25.1 mKonzept ist machbar und sicheronths and the actuarial 2-year local progression-free survival (LPFS), relapse-free survival (RFS), and OS rates were 67.3, 14.7, and 54.7 %, respectively. The HD group tended to show better tumor response (100 vs. 62.2 %, p = 0.039) and 2-year LPFS (85.7 vs. 59 %, p = 0.119), RFS (38.1 vs. 7.3 %, p = 0.063), and OS (83.3 vs. 44.3 %, p = 0.037) rates than the LD group. Multivariate analysis showed that tumor response was significantly associated with OS. SIB-IMRT is feasible and safe for patients with inoperable HCC.
Carabini, Louanne M; Moreland, Natalie C; Vealey, Ryan J; Bebawy, John F; Koski, Tyler R; Koht, Antoun; Gupta, Dhanesh K; Avram, Michael J
2018-02-01
Multilevel spine fusion surgery for adult deformity correction is associated with significant blood loss and coagulopathy. Tranexamic acid reduces blood loss in high-risk surgery, but the efficacy of a low-dose regimen is unknown. Sixty-one patients undergoing multilevel complex spinal fusion with and without osteotomies were randomly assigned to receive low-dose tranexamic acid (10 mg/kg loading dose, then 1 mg·kg -1 ·hr -1 throughout surgery) or placebo. The primary outcome was the total volume of red blood cells transfused intraoperatively. Thirty-one patients received tranexamic acid, and 30 patients received placebo. Patient demographics, risk of major transfusion, preoperative hemoglobin, and surgical risk of the 2 groups were similar. There was a significant decrease in total volume of red blood cells transfused (placebo group median 1460 mL vs. tranexamic acid group 1140 mL; median difference 463 mL, 95% confidence interval 15 to 914 mL, P = 0.034), with a decrease in cell saver transfusion (placebo group median 490 mL vs. tranexamic acid group 256 mL; median difference 166 mL, 95% confidence interval 0 to 368 mL, P = 0.042). The decrease in packed red blood cell transfusion did not reach statistical significance (placebo group median 1050 mL vs. tranexamic acid group 600 mL; median difference 300 mL, 95% confidence interval 0 to 600 mL, P = 0.097). Our results support the use of low-dose tranexamic acid during complex multilevel spine fusion surgery to decrease total red blood cell transfusion. Copyright © 2017 Elsevier Inc. All rights reserved.
Fraction of a dose absorbed estimation for structurally diverse low solubility compounds.
Sugano, Kiyohiko
2011-02-28
The purpose of the present study was to investigate the prediction accuracy of the fully mechanistic gastrointestinal unified theoretical (GUT) framework for in vivo oral absorption of low solubility drugs. Solubility in biorelevant media, molecular weight, logP(oct), pK(a), Caco-2 permeability, dose and particle size were used as the input parameters. To neglect the effect of the low stomach pH on dissolution of a drug, the fraction of a dose absorbed (Fa%) of undissociable and free acids were used. In addition, Fa% of free base drugs with the high pH stomach was also included to increase the number of model drugs. In total twenty nine structurally diverse compounds were used as the model drugs. Fa% data at several doses and particle sizes in humans and dogs were collated from the literature (total 110 Fa% data). In approximately 80% cases, the prediction error was within 2 fold, suggesting that the GUT framework has practical predictability for drug discovery, but not for drug development. The GUT framework appropriately captured the dose and particle size dependency of Fa% as the particle drifting effect was taken into account. It should be noted that the present validation results cannot be applied for salt form cases and other special formulations such as solid dispersions and emulsion formulations. Copyright © 2010 Elsevier B.V. All rights reserved.
Hsu, Wan-Ling; Tatsukawa, Yoshimi; Neriishi, Kazuo; Yamada, Michiko; Cologne, John; Fujiwara, Saeko
2010-01-01
In studying the late health effects of atomic-bomb (A-bomb) survivors, earlier findings were that white blood cell (WBC) count increased with radiation dose in cross-sectional studies. However, a persistent effect of radiation on WBC count and other risk factors has yet to be confirmed. The objectives of the present study were 1) to examine the longitudinal relationship between A-bomb radiation dose and WBC and differential WBC counts among A-bomb survivors and 2) to investigate the potential confounding risk factors (such as age at exposure and smoking status) as well as modification of the radiation dose-response. A total of 7,562 A-bomb survivors in Hiroshima and Nagasaki were included in this study from 1964-2004. A linear mixed model was applied using the repeated WBC measurements. During the study period, a secular downward trend of WBC count was observed. Radiation exposure was a significant risk factor for elevated WBC and differential WBC counts over time. A significant increase of WBC counts among survivors with high radiation dose (> 2 Gy) was detected in men exposed below the age of 20 and in women regardless of age at exposure. Effects on WBC of low dose radiation remain unclear, however. Cigarette smoking produced the most pronounced effect on WBC counts and its impact was much larger than that of radiation exposure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edmondson, Elijah F., E-mail: elijah.edmondson@colostate.edu; Hunter, Nancy R.; Weil, Michael M.
2015-07-15
Purpose: To investigate differences in tumor histotype, incidence, latency, and strain susceptibility in mice exposed to single-dose or clinically relevant, fractioned-dose γ-ray radiation. Methods and Materials: C3Hf/Kam and C57BL/6J mice were locally irradiated to the right hindlimb with either single large doses between 10 and 70 Gy or fractionated doses totaling 40 to 80 Gy delivered at 2-Gy/d fractions, 5 d/wk, for 4 to 8 weeks. The mice were closely evaluated for tumor development in the irradiated field for 800 days after irradiation, and all tumors were characterized histologically. Results: A total of 210 tumors were induced within the radiation field in 788 mice. Anmore » overall decrease in tumor incidence was observed after fractionated irradiation (16.4%) in comparison with single-dose irradiation (36.1%). Sarcomas were the predominant postirradiation tumor observed (n=201), with carcinomas occurring less frequently (n=9). The proportion of mice developing tumors increased significantly with total dose for both single-dose and fractionated schedules, and latencies were significantly decreased in mice exposed to larger total doses. C3Hf/Kam mice were more susceptible to tumor induction than C57BL/6J mice after single-dose irradiation; however, significant differences in tumor susceptibilities after fractionated radiation were not observed. For both strains of mice, osteosarcomas and hemangiosarcomas were significantly more common after fractionated irradiation, whereas fibrosarcomas and malignant fibrous histiocytomas were significantly more common after single-dose irradiation. Conclusions: This study investigated the tumorigenic effect of acute large doses in comparison with fractionated radiation in which both the dose and delivery schedule were similar to those used in clinical radiation therapy. Differences in tumor histotype after single-dose or fractionated radiation exposures provide novel in vivo evidence for differences in tumor susceptibility among stromal cell populations.« less
TH-CD-201-08: Flexible Dosimeter Bands for Whole-Body Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, T; Fahimian, B; Pratx, G
Purpose: The two commonly used radiotherapy techniques are total body irradiation (TBI) and the total skin irradiation (TSI). In order to ensure the accuracy of the prescription beams, the dose received throughout the entire body must be checked using dosimetry. However, the available number of data points is limited as the dosimeters are manually placed on the patient. We developed a flexible and wearable dosimeter that can collect 1D continuous dose information around the peripheral of the patients’ body, including areas obscured from the beam path. Methods: The flexible dosimeter bands are fabricated by embedding storage phosphor powders in amore » thin layer of non-toxic silicone based elastomer (PDMS). An additional elastomer layer is formed on top of the phosphor layer to provide additional mechanical support for the dosimeter. Once the curing process is complete, the dosimeter is cut into multiple bands and rolled into spools prior to use. Results: The dose responses are tested using a preclinical cabinet X-ray system, where the readout is performed with a storage phosphor reader. Results show that the dose calibration factor is ∼1400 (A.U./Gy) from the beam center. Also, 1-D dose distribution experiment was performed in water phantoms, where preliminary results demonstrate that the dose in water is indeed attenuated compared to in air. Conclusion: Dose response and high-resolution 1-D dosimetry is demonstrated using the flexible dosimeters. By providing a detailed spatial description of the beam dose profile, we expect that the dosimeter bands may aid in enhancing the current existing modality in dosimetry. Since the dosimeter is flexible (can retract back to its original length), they can be comfortably worn around the patient. Potentially, multiple 1-D dose information can be stitched together and extrapolated to provide a coarse 3-D image of the dose distribution. This work was supported by funding from the Cutaneous Lymphoma Foundation under the CLARIONS grant.« less