Sample records for high visual quality

  1. Quality metrics in high-dimensional data visualization: an overview and systematization.

    PubMed

    Bertini, Enrico; Tatu, Andrada; Keim, Daniel

    2011-12-01

    In this paper, we present a systematization of techniques that use quality metrics to help in the visual exploration of meaningful patterns in high-dimensional data. In a number of recent papers, different quality metrics are proposed to automate the demanding search through large spaces of alternative visualizations (e.g., alternative projections or ordering), allowing the user to concentrate on the most promising visualizations suggested by the quality metrics. Over the last decade, this approach has witnessed a remarkable development but few reflections exist on how these methods are related to each other and how the approach can be developed further. For this purpose, we provide an overview of approaches that use quality metrics in high-dimensional data visualization and propose a systematization based on a thorough literature review. We carefully analyze the papers and derive a set of factors for discriminating the quality metrics, visualization techniques, and the process itself. The process is described through a reworked version of the well-known information visualization pipeline. We demonstrate the usefulness of our model by applying it to several existing approaches that use quality metrics, and we provide reflections on implications of our model for future research. © 2010 IEEE

  2. Pedestrian visual recommendation in Kertanegara - Semeru corridor in Malang City

    NASA Astrophysics Data System (ADS)

    Cosalia, V. B.

    2017-06-01

    Streetscape could be the first impression to see an urban area. One of the streerscape that should be attended to it is corridor of Jl. Kertanegara - Semeru since at that corridor is the road corridor having the strong caracter also as the one of the main axes in Malang city. This research is aim knowing the visual quality also the exact structuring rcommendation for Jl. Kertanegara - Semeru based on pedestrian’s visual. The methode used to this research is Scenic Beauty Estimation (SBE) and used historic study. There is several variables used, they are scale space, visual flexibility, beauty, emphasis, balance and dominant. Based on those variable the pedestrians as a respondent doing the assessment. Based on the result of SBE have been done, it is showed that the visual quality in Corridor Kertanegara Semeru is well enough since the result showed that there are 10 photos in low visual quality in Jl. Semeru and 14 photos in high visual quality in Jl. Kertanegara, Jl. Tugu dan Jl. Kahuripan. By the historic study and based on high visual quality reference doing the structuring recommendation in part of landscape having the low visual quality.

  3. Sight or Scent: Lemur Sensory Reliance in Detecting Food Quality Varies with Feeding Ecology

    PubMed Central

    Rushmore, Julie; Leonhardt, Sara D.; Drea, Christine M.

    2012-01-01

    Visual and olfactory cues provide important information to foragers, yet we know little about species differences in sensory reliance during food selection. In a series of experimental foraging studies, we examined the relative reliance on vision versus olfaction in three diurnal, primate species with diverse feeding ecologies, including folivorous Coquerel's sifakas (Propithecus coquereli), frugivorous ruffed lemurs (Varecia variegata spp), and generalist ring-tailed lemurs (Lemur catta). We used animals with known color-vision status and foods for which different maturation stages (and hence quality) produce distinct visual and olfactory cues (the latter determined chemically). We first showed that lemurs preferentially selected high-quality foods over low-quality foods when visual and olfactory cues were simultaneously available for both food types. Next, using a novel apparatus in a series of discrimination trials, we either manipulated food quality (while holding sensory cues constant) or manipulated sensory cues (while holding food quality constant). Among our study subjects that showed relatively strong preferences for high-quality foods, folivores required both sensory cues combined to reliably identify their preferred foods, whereas generalists could identify their preferred foods using either cue alone, and frugivores could identify their preferred foods using olfactory, but not visual, cues alone. Moreover, when only high-quality foods were available, folivores and generalists used visual rather than olfactory cues to select food, whereas frugivores used both cue types equally. Lastly, individuals in all three of the study species predominantly relied on sight when choosing between low-quality foods, but species differed in the strength of their sensory biases. Our results generally emphasize visual over olfactory reliance in foraging lemurs, but we suggest that the relative sensory reliance of animals may vary with their feeding ecology. PMID:22870229

  4. Global motion compensated visual attention-based video watermarking

    NASA Astrophysics Data System (ADS)

    Oakes, Matthew; Bhowmik, Deepayan; Abhayaratne, Charith

    2016-11-01

    Imperceptibility and robustness are two key but complementary requirements of any watermarking algorithm. Low-strength watermarking yields high imperceptibility but exhibits poor robustness. High-strength watermarking schemes achieve good robustness but often suffer from embedding distortions resulting in poor visual quality in host media. This paper proposes a unique video watermarking algorithm that offers a fine balance between imperceptibility and robustness using motion compensated wavelet-based visual attention model (VAM). The proposed VAM includes spatial cues for visual saliency as well as temporal cues. The spatial modeling uses the spatial wavelet coefficients while the temporal modeling accounts for both local and global motion to arrive at the spatiotemporal VAM for video. The model is then used to develop a video watermarking algorithm, where a two-level watermarking weighting parameter map is generated from the VAM saliency maps using the saliency model and data are embedded into the host image according to the visual attentiveness of each region. By avoiding higher strength watermarking in the visually attentive region, the resulting watermarked video achieves high perceived visual quality while preserving high robustness. The proposed VAM outperforms the state-of-the-art video visual attention methods in joint saliency detection and low computational complexity performance. For the same embedding distortion, the proposed visual attention-based watermarking achieves up to 39% (nonblind) and 22% (blind) improvement in robustness against H.264/AVC compression, compared to existing watermarking methodology that does not use the VAM. The proposed visual attention-based video watermarking results in visual quality similar to that of low-strength watermarking and a robustness similar to those of high-strength watermarking.

  5. Impacts of deer herbivory and visual grading on the early performance of high-quality oak planting stock in Tennessee, USA

    Treesearch

    Christopher M. Oswalt; Wayne K. Clatterbuck; Allan E. Houston

    2006-01-01

    The growth of outplanted high-quality 1-0 northern red oak (Quercus rubra L.) seedlings, growth differences between two categories of visually graded seedlings and herbivory by white-tail deer (Odocoileus virginianus (Boddaert)) were examined after two growing seasons. Seedlings were planted in plots receiving three overstory treatments (high grade,...

  6. Visual Grading and Quality of 1-0 Northern Red Oak Seedlings

    Treesearch

    S.L. Clark; S.E. Scblarbaum; Paul P. Kormanik

    2000-01-01

    Past research has used detailed measurements of various growth characteristics to determine seedling grades and quality of northern red oak nursery stock This study evaluates the effectiveness ofa visual grading process. similar to thosefound in commercial nursery operations, to distinguish high quality seedlings. Northern red oak (Quercus rubra...

  7. Visual resources of the New Jersey Pine Barrens: integrating visual resources into the planning process

    Treesearch

    John W. Sinton

    1979-01-01

    The first purpose of this study was to deter-mine the visual quality of New Jersey Pine Barrens forests according to residents of the area. The goal of the study was to determine how to manage Pine Barrens forests to obtain high visual quality within the framework of residents' preferences, available by the Federal Omnibus Parks Acts of 1978 and proposed New...

  8. A high-quality high-fidelity visualization of the September 11 attack on the World Trade Center.

    PubMed

    Rosen, Paul; Popescu, Voicu; Hoffmann, Christoph; Irfanoglu, Ayhan

    2008-01-01

    In this application paper, we describe the efforts of a multidisciplinary team towards producing a visualization of the September 11 Attack on the North Tower of New York's World Trade Center. The visualization was designed to meet two requirements. First, the visualization had to depict the impact with high fidelity, by closely following the laws of physics. Second, the visualization had to be eloquent to a nonexpert user. This was achieved by first designing and computing a finite-element analysis (FEA) simulation of the impact between the aircraft and the top 20 stories of the building, and then by visualizing the FEA results with a state-of-the-art commercial animation system. The visualization was enabled by an automatic translator that converts the simulation data into an animation system 3D scene. We built upon a previously developed translator. The translator was substantially extended to enable and control visualization of fire and of disintegrating elements, to better scale with the number of nodes and number of states, to handle beam elements with complex profiles, and to handle smoothed particle hydrodynamics liquid representation. The resulting translator is a powerful automatic and scalable tool for high-quality visualization of FEA results.

  9. A no-reference image and video visual quality metric based on machine learning

    NASA Astrophysics Data System (ADS)

    Frantc, Vladimir; Voronin, Viacheslav; Semenishchev, Evgenii; Minkin, Maxim; Delov, Aliy

    2018-04-01

    The paper presents a novel visual quality metric for lossy compressed video quality assessment. High degree of correlation with subjective estimations of quality is due to using of a convolutional neural network trained on a large amount of pairs video sequence-subjective quality score. We demonstrate how our predicted no-reference quality metric correlates with qualitative opinion in a human observer study. Results are shown on the EVVQ dataset with comparison existing approaches.

  10. Retinal Image Quality During Accommodation

    PubMed Central

    López-Gil, N.; Martin, J.; Liu, T.; Bradley, A.; Díaz-Muñoz, D.; Thibos, L.

    2013-01-01

    Purpose We asked if retinal image quality is maximum during accommodation, or sub-optimal due to accommodative error, when subjects perform an acuity task. Methods Subjects viewed a monochromatic (552nm), high-contrast letter target placed at various viewing distances. Wavefront aberrations of the accommodating eye were measured near the endpoint of an acuity staircase paradigm. Refractive state, defined as the optimum target vergence for maximising retinal image quality, was computed by through-focus wavefront analysis to find the power of the virtual correcting lens that maximizes visual Strehl ratio. Results Despite changes in ocular aberrations and pupil size during binocular viewing, retinal image quality and visual acuity typically remain high for all target vergences. When accommodative errors lead to sub-optimal retinal image quality, acuity and measured image quality both decline. However, the effect of accommodation errors of on visual acuity are mitigated by pupillary constriction associated with accommodation and binocular convergence and also to binocular summation of dissimilar retinal image blur. Under monocular viewing conditions some subjects displayed significant accommodative lag that reduced visual performance, an effect that was exacerbated by pharmacological dilation of the pupil. Conclusions Spurious measurement of accommodative error can be avoided when the image quality metric used to determine refractive state is compatible with the focusing criteria used by the visual system to control accommodation. Real focusing errors of the accommodating eye do not necessarily produce a reliably measurable loss of image quality or clinically significant loss of visual performance, probably because of increased depth-of-focus due to pupil constriction. When retinal image quality is close to maximum achievable (given the eye’s higher-order aberrations), acuity is also near maximum. A combination of accommodative lag, reduced image quality, and reduced visual function may be a useful sign for diagnosing functionally-significant accommodative errors indicating the need for therapeutic intervention. PMID:23786386

  11. Retinal image quality during accommodation.

    PubMed

    López-Gil, Norberto; Martin, Jesson; Liu, Tao; Bradley, Arthur; Díaz-Muñoz, David; Thibos, Larry N

    2013-07-01

    We asked if retinal image quality is maximum during accommodation, or sub-optimal due to accommodative error, when subjects perform an acuity task. Subjects viewed a monochromatic (552 nm), high-contrast letter target placed at various viewing distances. Wavefront aberrations of the accommodating eye were measured near the endpoint of an acuity staircase paradigm. Refractive state, defined as the optimum target vergence for maximising retinal image quality, was computed by through-focus wavefront analysis to find the power of the virtual correcting lens that maximizes visual Strehl ratio. Despite changes in ocular aberrations and pupil size during binocular viewing, retinal image quality and visual acuity typically remain high for all target vergences. When accommodative errors lead to sub-optimal retinal image quality, acuity and measured image quality both decline. However, the effect of accommodation errors of on visual acuity are mitigated by pupillary constriction associated with accommodation and binocular convergence and also to binocular summation of dissimilar retinal image blur. Under monocular viewing conditions some subjects displayed significant accommodative lag that reduced visual performance, an effect that was exacerbated by pharmacological dilation of the pupil. Spurious measurement of accommodative error can be avoided when the image quality metric used to determine refractive state is compatible with the focusing criteria used by the visual system to control accommodation. Real focusing errors of the accommodating eye do not necessarily produce a reliably measurable loss of image quality or clinically significant loss of visual performance, probably because of increased depth-of-focus due to pupil constriction. When retinal image quality is close to maximum achievable (given the eye's higher-order aberrations), acuity is also near maximum. A combination of accommodative lag, reduced image quality, and reduced visual function may be a useful sign for diagnosing functionally-significant accommodative errors indicating the need for therapeutic intervention. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  12. Assessment of visual landscape quality using IKONOS imagery.

    PubMed

    Ozkan, Ulas Yunus

    2014-07-01

    The assessment of visual landscape quality is of importance to the management of urban woodlands. Satellite remote sensing may be used for this purpose as a substitute for traditional survey techniques that are both labour-intensive and time-consuming. This study examines the association between the quality of the perceived visual landscape in urban woodlands and texture measures extracted from IKONOS satellite data, which features 4-m spatial resolution and four spectral bands. The study was conducted in the woodlands of Istanbul (the most important element of urban mosaic) lying along both shores of the Bosporus Strait. The visual quality assessment applied in this study is based on the perceptual approach and was performed via a survey of expressed preferences. For this purpose, representative photographs of real scenery were used to elicit observers' preferences. A slide show comprising 33 images was presented to a group of 153 volunteers (all undergraduate students), and they were asked to rate the visual quality of each on a 10-point scale (1 for very low visual quality, 10 for very high). Average visual quality scores were calculated for landscape. Texture measures were acquired using the two methods: pixel-based and object-based. Pixel-based texture measures were extracted from the first principle component (PC1) image. Object-based texture measures were extracted by using the original four bands. The association between image texture measures and perceived visual landscape quality was tested via Pearson's correlation coefficient. The analysis found a strong linear association between image texture measures and visual quality. The highest correlation coefficient was calculated between standard deviation of gray levels (SDGL) (one of the pixel-based texture measures) and visual quality (r = 0.82, P < 0.05). The results showed that perceived visual quality of urban woodland landscapes can be estimated by using texture measures extracted from satellite data in combination with appropriate modelling techniques.

  13. Predictors of vision impairment in Multiple Sclerosis.

    PubMed

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  14. Visual assessment of CPR quality during pediatric cardiac arrest: does point of view matter?

    PubMed

    Jones, Angela; Lin, Yiqun; Nettel-Aguirre, Alberto; Gilfoyle, Elaine; Cheng, Adam

    2015-05-01

    In many clinical settings, providers rely on visual assessment when delivering feedback on CPR quality. Little is known about the accuracy of visual assessment of CPR quality. We aimed to determine how accurate pediatric providers are in their visual assessment of CPR quality and to identify the optimal position relative to the patient for accurate CPR assessment. We videotaped high-quality CPR (based on 2010 American Heart Association guidelines) and 3 variations of poor quality CPR in a simulated resuscitation, filmed from the foot, head and the side of the manikin. Participants watched 12 videos and completed a questionnaire to assess CPR quality. One hundred and twenty-five participants were recruited. The overall accuracy of visual assessment of CPR quality was 65.6%. Accuracy was better from the side (70.8%) and foot (68.8%) of the bed when compared to the head of the bed (57.2%; p<0.001). The side was the best position for assessing depth (p<0.001). Rate assessment was equivalent between positions (p=0.58). The side and foot of the bed were superior to the head when assessing chest recoil (p<0.001). Factors associated with increased accuracy in visual assessment of CPR quality included recent CPR course completion (p=0.034) and involvement in more cardiac arrests as a team member (p=0.003). Healthcare providers struggle to accurately assess the quality of CPR using visual assessment. If visual assessment is being used, providers should stand at the side of the bed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism.

    PubMed

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-10-01

    To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Designing multifocal corneal models to correct presbyopia by laser ablation

    NASA Astrophysics Data System (ADS)

    Alarcón, Aixa; Anera, Rosario G.; Del Barco, Luis Jiménez; Jiménez, José R.

    2012-01-01

    Two multifocal corneal models and an aspheric model designed to correct presbyopia by corneal photoablation were evaluated. The design of each model was optimized to achieve the best visual quality possible for both near and distance vision. In addition, we evaluated the effect of myosis and pupil decentration on visual quality. The corrected model with the central zone for near vision provides better results since it requires less ablated corneal surface area, permits higher addition values, presents stabler visual quality with pupil-size variations and lower high-order aberrations.

  17. The Social Experiences of High School Students with Visual Impairments

    ERIC Educational Resources Information Center

    Jessup, Glenda; Bundy, Anita C.; Broom, Alex; Hancock, Nicola

    2017-01-01

    Introduction: This study explores the social experiences in high school of students with visual impairments. Methods: Experience sampling methodology was used to examine (a) how socially included students with visual impairments feel, (b) the internal qualities of their activities, and (c) the factors that influence a sense of inclusion. Twelve…

  18. Cultivating Common Ground: Integrating Standards-Based Visual Arts, Math and Literacy in High-Poverty Urban Classrooms

    ERIC Educational Resources Information Center

    Cunnington, Marisol; Kantrowitz, Andrea; Harnett, Susanne; Hill-Ries, Aline

    2014-01-01

    The "Framing Student Success: Connecting Rigorous Visual Arts, Math and Literacy Learning" experimental demonstration project was designed to develop and test an instructional program integrating high-quality, standards-based instruction in the visual arts, math, and literacy. Developed and implemented by arts-in-education organization…

  19. Information efficiency in visual communication

    NASA Astrophysics Data System (ADS)

    Alter-Gartenberg, Rachel; Rahman, Zia-ur

    1993-08-01

    This paper evaluates the quantization process in the context of the end-to-end performance of the visual-communication channel. Results show that the trade-off between data transmission and visual quality revolves around the information in the acquired signal, not around its energy. Improved information efficiency is gained by frequency dependent quantization that maintains the information capacity of the channel and reduces the entropy of the encoded signal. Restorations with energy bit-allocation lose both in sharpness and clarity relative to restorations with information bit-allocation. Thus, quantization with information bit-allocation is preferred for high information efficiency and visual quality in optimized visual communication.

  20. Information efficiency in visual communication

    NASA Technical Reports Server (NTRS)

    Alter-Gartenberg, Rachel; Rahman, Zia-Ur

    1993-01-01

    This paper evaluates the quantization process in the context of the end-to-end performance of the visual-communication channel. Results show that the trade-off between data transmission and visual quality revolves around the information in the acquired signal, not around its energy. Improved information efficiency is gained by frequency dependent quantization that maintains the information capacity of the channel and reduces the entropy of the encoded signal. Restorations with energy bit-allocation lose both in sharpness and clarity relative to restorations with information bit-allocation. Thus, quantization with information bit-allocation is preferred for high information efficiency and visual quality in optimized visual communication.

  1. Development and validation of a visual grading scale for assessing image quality of AP pelvis radiographic images.

    PubMed

    Mraity, Hussien A A B; England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter

    2016-01-01

    The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.

  2. Development and validation of a visual grading scale for assessing image quality of AP pelvis radiographic images

    PubMed Central

    England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter

    2016-01-01

    Objective: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Methods: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. Results: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). Conclusion: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. Advances in knowledge: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality. PMID:26943836

  3. Analysis of visual quality improvements provided by known tools for HDR content

    NASA Astrophysics Data System (ADS)

    Kim, Jaehwan; Alshina, Elena; Lee, JongSeok; Park, Youngo; Choi, Kwang Pyo

    2016-09-01

    In this paper, the visual quality of different solutions for high dynamic range (HDR) compression using MPEG test contents is analyzed. We also simulate the method for an efficient HDR compression which is based on statistical property of the signal. The method is compliant with HEVC specification and also easily compatible with other alternative methods which might require HEVC specification changes. It was subjectively tested on commercial TVs and compared with alternative solutions for HDR coding. Subjective visual quality tests were performed using SUHD TVs model which is SAMSUNG JS9500 with maximum luminance up to 1000nit in test. The solution that is based on statistical property shows not only improvement of objective performance but improvement of visual quality compared to other HDR solutions, while it is compatible with HEVC specification.

  4. Nutritional assessment and diet quality of visually impaired Spanish children.

    PubMed

    Montero, Pilar

    2005-01-01

    The visually impaired represents a fairly numerous group in Spain although no data on their nutritional status has previously been published. This work aims to assess the nutritional state of a sample of visually impaired children and the quality of their diet. The sample comprised 229 boys and girls aged between 8 and 18 years (mean = 14, SD = 2.6), all of whom had a visual discapacity and were students of the Centros de Recursos Educativos (CREs; Educational Resources Centres) of the Organización Nacional de Ciegos de España (ONCE; Spanish National Organization for the Blind). This sample featured a high prevalence of overweight (25.8%) and obesity (11.8%) according to the international standard. The mean daily energy consumption and the quantity of carbohydrates, fats, proteins and fibre were greater in boys (2604 kcal day(-1); 290 g of carbohydrates, 126 g of fats and 90 g of proteins) than in girls (2159 kcal day(-1), 232 g of carbohydrates, 107 g of fats and 80 g of proteins). No differences in diet intake according to degree of visual impairment were found. Their diet was unbalanced in comparison with the nutritional objectives for the Spanish population, since consumption of carbohydrates was low and that of fats was very high. The results relating to the quality of the diet reveal quite large deviations from the Mediterranean model. Only 11.9% of the whole sample had a value corresponding to a good quality diet. The pattern of dietary consumption was the same as that observed in non visually impaired children in Spain in quantity and quality, nevertheless the prevalence of overweight and obesity is higher than in children without visual handicaps.

  5. Designing sound and visual components for enhancement of urban soundscapes.

    PubMed

    Hong, Joo Young; Jeon, Jin Yong

    2013-09-01

    The aim of this study is to investigate the effect of audio-visual components on environmental quality to improve soundscape. Natural sounds with road traffic noise and visual components in urban streets were evaluated through laboratory experiments. Waterfall and stream water sounds, as well as bird sounds, were selected to enhance the soundscape. Sixteen photomontages of a streetscape were constructed in combination with two types of water features and three types of vegetation which were chosen as positive visual components. The experiments consisted of audio-only, visual-only, and audio-visual conditions. The preferences and environmental qualities of the stimuli were evaluated by a numerical scale and 12 pairs of adjectives, respectively. The results showed that bird sounds were the most preferred among the natural sounds, while the sound of falling water was found to degrade the soundscape quality when the road traffic noise level was high. The visual effects of vegetation on aesthetic preference were significant, but those of water features relatively small. It was revealed that the perceptual dimensions of the environment were different from the noise levels. Particularly, the acoustic comfort factor related to soundscape quality considerably influenced preference for the overall environment at a higher level of road traffic noise.

  6. Wavefront-Guided Scleral Lens Correction in Keratoconus

    PubMed Central

    Marsack, Jason D.; Ravikumar, Ayeswarya; Nguyen, Chi; Ticak, Anita; Koenig, Darren E.; Elswick, James D.; Applegate, Raymond A.

    2014-01-01

    Purpose To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics; and to provide a detailed discussion of the process used to design, manufacture and evaluate wfgSCLs. Methods Fourteen eyes of 7 subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. Results The wfgSCL provided statistically lower levels of both lower-order RMS (p < 0.001) and higher-order RMS (p < 0.02) than an intermediate spherical equivalent scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p < < 0.001). However, the wfgSCL does not provide less higher-order RMS than the normal group (p = 0.41). Of the 14 eyes studied, 10 successfully reached the exit criteria, achieving residual higher-order root mean square wavefront error (HORMS) less than or within 1 SD of the levels experienced by normal, age-matched subjects. In addition, measures of visual image quality (logVSX, logNS and logLIB) for the 10 eyes were well distributed within the range of values seen in normal eyes. However, visual performance as measured by high contrast acuity did not reach normal, age-matched levels, which is in agreement with prior results associated with the acute application of wavefront correction to KC eyes. Conclusions Wavefront-guided scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease, and can provide visual image quality equivalent to that seen in normal eyes. Longer duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population. PMID:24830371

  7. Discovery learning model with geogebra assisted for improvement mathematical visual thinking ability

    NASA Astrophysics Data System (ADS)

    Juandi, D.; Priatna, N.

    2018-05-01

    The main goal of this study is to improve the mathematical visual thinking ability of high school student through implementation the Discovery Learning Model with Geogebra Assisted. This objective can be achieved through study used quasi-experimental method, with non-random pretest-posttest control design. The sample subject of this research consist of 62 senior school student grade XI in one of school in Bandung district. The required data will be collected through documentation, observation, written tests, interviews, daily journals, and student worksheets. The results of this study are: 1) Improvement students Mathematical Visual Thinking Ability who obtain learning with applied the Discovery Learning Model with Geogebra assisted is significantly higher than students who obtain conventional learning; 2) There is a difference in the improvement of students’ Mathematical Visual Thinking ability between groups based on prior knowledge mathematical abilities (high, medium, and low) who obtained the treatment. 3) The Mathematical Visual Thinking Ability improvement of the high group is significantly higher than in the medium and low groups. 4) The quality of improvement ability of high and low prior knowledge is moderate category, in while the quality of improvement ability in the high category achieved by student with medium prior knowledge.

  8. Progressive low-bitrate digital color/monochrome image coding by neuro-fuzzy clustering

    NASA Astrophysics Data System (ADS)

    Mitra, Sunanda; Meadows, Steven

    1997-10-01

    Color image coding at low bit rates is an area of research that is just being addressed in recent literature since the problems of storage and transmission of color images are becoming more prominent in many applications. Current trends in image coding exploit the advantage of subband/wavelet decompositions in reducing the complexity in optimal scalar/vector quantizer (SQ/VQ) design. Compression ratios (CRs) of the order of 10:1 to 20:1 with high visual quality have been achieved by using vector quantization of subband decomposed color images in perceptually weighted color spaces. We report the performance of a recently developed adaptive vector quantizer, namely, AFLC-VQ for effective reduction in bit rates while maintaining high visual quality of reconstructed color as well as monochrome images. For 24 bit color images, excellent visual quality is maintained upto a bit rate reduction to approximately 0.48 bpp (for each color plane or monochrome 0.16 bpp, CR 50:1) by using the RGB color space. Further tuning of the AFLC-VQ, and addition of an entropy coder module after the VQ stage results in extremely low bit rates (CR 80:1) for good quality, reconstructed images. Our recent study also reveals that for similar visual quality, RGB color space requires less bits/pixel than either the YIQ, or HIS color space for storing the same information when entropy coding is applied. AFLC-VQ outperforms other standard VQ and adaptive SQ techniques in retaining visual fidelity at similar bit rate reduction.

  9. Simulation Design for Off-Line Training of Practical Lean Manufacturing Concepts for Visual Inspection

    ERIC Educational Resources Information Center

    Tetteh, Edem; McWilliams, Douglas

    2010-01-01

    Customer needs for high-quality goods and the risk of product-liability litigation against businesses have made companies look for a way to sustain quality assurance in their products and services. Lean manufacturing is the latest and most successful system being used by companies to turn their business around. Visual inspection plays an important…

  10. Color extended visual cryptography using error diffusion.

    PubMed

    Kang, InKoo; Arce, Gonzalo R; Lee, Heung-Kyu

    2011-01-01

    Color visual cryptography (VC) encrypts a color secret message into n color halftone image shares. Previous methods in the literature show good results for black and white or gray scale VC schemes, however, they are not sufficient to be applied directly to color shares due to different color structures. Some methods for color visual cryptography are not satisfactory in terms of producing either meaningless shares or meaningful shares with low visual quality, leading to suspicion of encryption. This paper introduces the concept of visual information pixel (VIP) synchronization and error diffusion to attain a color visual cryptography encryption method that produces meaningful color shares with high visual quality. VIP synchronization retains the positions of pixels carrying visual information of original images throughout the color channels and error diffusion generates shares pleasant to human eyes. Comparisons with previous approaches show the superior performance of the new method.

  11. Fuzzy Logic-based expert system for evaluating cake quality of freeze-dried formulations.

    PubMed

    Trnka, Hjalte; Wu, Jian X; Van De Weert, Marco; Grohganz, Holger; Rantanen, Jukka

    2013-12-01

    Freeze-drying of peptide and protein-based pharmaceuticals is an increasingly important field of research. The diverse nature of these compounds, limited understanding of excipient functionality, and difficult-to-analyze quality attributes together with the increasing importance of the biosimilarity concept complicate the development phase of safe and cost-effective drug products. To streamline the development phase and to make high-throughput formulation screening possible, efficient solutions for analyzing critical quality attributes such as cake quality with minimal material consumption are needed. The aim of this study was to develop a fuzzy logic system based on image analysis (IA) for analyzing cake quality. Freeze-dried samples with different visual quality attributes were prepared in well plates. Imaging solutions together with image analytical routines were developed for extracting critical visual features such as the degree of cake collapse, glassiness, and color uniformity. On the basis of the IA outputs, a fuzzy logic system for analysis of these freeze-dried cakes was constructed. After this development phase, the system was tested with a new screening well plate. The developed fuzzy logic-based system was found to give comparable quality scores with visual evaluation, making high-throughput classification of cake quality possible. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.

  12. Professional Standards for Visual Arts Educators

    ERIC Educational Resources Information Center

    National Art Education Association, 2009

    2009-01-01

    The National Art Education Association (NAEA) is committed to ensuring that all students have access to a high quality, certified visual arts educator in every K-12 public school across the United States, recognizing that effective arts instruction is a core component of 21st-century education. "Professional Standards for Visual Arts…

  13. FISH Oracle 2: a web server for integrative visualization of genomic data in cancer research.

    PubMed

    Mader, Malte; Simon, Ronald; Kurtz, Stefan

    2014-03-31

    A comprehensive view on all relevant genomic data is instrumental for understanding the complex patterns of molecular alterations typically found in cancer cells. One of the most effective ways to rapidly obtain an overview of genomic alterations in large amounts of genomic data is the integrative visualization of genomic events. We developed FISH Oracle 2, a web server for the interactive visualization of different kinds of downstream processed genomics data typically available in cancer research. A powerful search interface and a fast visualization engine provide a highly interactive visualization for such data. High quality image export enables the life scientist to easily communicate their results. A comprehensive data administration allows to keep track of the available data sets. We applied FISH Oracle 2 to published data and found evidence that, in colorectal cancer cells, the gene TTC28 may be inactivated in two different ways, a fact that has not been published before. The interactive nature of FISH Oracle 2 and the possibility to store, select and visualize large amounts of downstream processed data support life scientists in generating hypotheses. The export of high quality images supports explanatory data visualization, simplifying the communication of new biological findings. A FISH Oracle 2 demo server and the software is available at http://www.zbh.uni-hamburg.de/fishoracle.

  14. Human Connectome Project Informatics: quality control, database services, and data visualization

    PubMed Central

    Marcus, Daniel S.; Harms, Michael P.; Snyder, Abraham Z.; Jenkinson, Mark; Wilson, J Anthony; Glasser, Matthew F.; Barch, Deanna M.; Archie, Kevin A.; Burgess, Gregory C.; Ramaratnam, Mohana; Hodge, Michael; Horton, William; Herrick, Rick; Olsen, Timothy; McKay, Michael; House, Matthew; Hileman, Michael; Reid, Erin; Harwell, John; Coalson, Timothy; Schindler, Jon; Elam, Jennifer S.; Curtiss, Sandra W.; Van Essen, David C.

    2013-01-01

    The Human Connectome Project (HCP) has developed protocols, standard operating and quality control procedures, and a suite of informatics tools to enable high throughput data collection, data sharing, automated data processing and analysis, and data mining and visualization. Quality control procedures include methods to maintain data collection consistency over time, to measure head motion, and to establish quantitative modality-specific overall quality assessments. Database services developed as customizations of the XNAT imaging informatics platform support both internal daily operations and open access data sharing. The Connectome Workbench visualization environment enables user interaction with HCP data and is increasingly integrated with the HCP's database services. Here we describe the current state of these procedures and tools and their application in the ongoing HCP study. PMID:23707591

  15. Selecting islands and shoals for conservation based on biological and aesthetic criteria

    USGS Publications Warehouse

    Knutson, M.G.; Leopold, D.J.; Smardon, R.C.

    1993-01-01

    Consideration of biological quality has long been an important component of rating areas for conservation. Often these same areas are highly valued by people for aesthetic reasons, creating demands for housing and recreation that may conflict with protection plans for these habitats. Most methods of selecting land for conservation purposes use biological factors alone. For some land areas, analysis of aesthetic qualities is also important in describing the scenic value of undisturbed land. A method for prioritizing small islands and shoals based on both biological and visual quality factors is presented here. The study included 169 undeveloped islands and shoals a??0.8 ha in the Thousand Islands Region of the St. Lawrence River, New York. Criteria such as critical habitat for uncommon plant and animal species were considered together with visual quality and incorporated into a rating system that ranked the islands and shoals according to their priority for conservation management and protection from development. Biological factors were determined based on previous research and a field survey. Visual quality was determined by visual diagnostic criteria developed from public responses to photographs of a sample of islands. Variables such as elevation, soil depth, and type of plant community can be used to classify islands into different categories of visual quality but are unsuccessful in classifying islands into categories of overall biological quality.

  16. Evaluation of an organic light-emitting diode display for precise visual stimulation.

    PubMed

    Ito, Hiroyuki; Ogawa, Masaki; Sunaga, Shoji

    2013-06-11

    A new type of visual display for presentation of a visual stimulus with high quality was assessed. The characteristics of an organic light-emitting diode (OLED) display (Sony PVM-2541, 24.5 in.; Sony Corporation, Tokyo, Japan) were measured in detail from the viewpoint of its applicability to visual psychophysics. We found the new display to be superior to other display types in terms of spatial uniformity, color gamut, and contrast ratio. Changes in the intensity of luminance were sharper on the OLED display than those on a liquid crystal display. Therefore, such OLED displays could replace conventional cathode ray tube displays in vision research for high quality stimulus presentation. Benefits of using OLED displays in vision research were especially apparent in the fields of low-level vision, where precise control and description of the stimulus are needed, e.g., in mesopic or scotopic vision, color vision, and motion perception.

  17. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure

    PubMed Central

    Stringham, James M.; Stringham, Nicole T.; O’Brien, Kevin J.

    2017-01-01

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased “screen time” (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months’ supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures (p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo (p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation. PMID:28661438

  18. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure.

    PubMed

    Stringham, James M; Stringham, Nicole T; O'Brien, Kevin J

    2017-06-29

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased "screen time" (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months' supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures ( p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo ( p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation.

  19. Optimizing wavefront-guided corrections for highly aberrated eyes in the presence of registration uncertainty

    PubMed Central

    Shi, Yue; Queener, Hope M.; Marsack, Jason D.; Ravikumar, Ayeswarya; Bedell, Harold E.; Applegate, Raymond A.

    2013-01-01

    Dynamic registration uncertainty of a wavefront-guided correction with respect to underlying wavefront error (WFE) inevitably decreases retinal image quality. A partial correction may improve average retinal image quality and visual acuity in the presence of registration uncertainties. The purpose of this paper is to (a) develop an algorithm to optimize wavefront-guided correction that improves visual acuity given registration uncertainty and (b) test the hypothesis that these corrections provide improved visual performance in the presence of these uncertainties as compared to a full-magnitude correction or a correction by Guirao, Cox, and Williams (2002). A stochastic parallel gradient descent (SPGD) algorithm was used to optimize the partial-magnitude correction for three keratoconic eyes based on measured scleral contact lens movement. Given its high correlation with logMAR acuity, the retinal image quality metric log visual Strehl was used as a predictor of visual acuity. Predicted values of visual acuity with the optimized corrections were validated by regressing measured acuity loss against predicted loss. Measured loss was obtained from normal subjects viewing acuity charts that were degraded by the residual aberrations generated by the movement of the full-magnitude correction, the correction by Guirao, and optimized SPGD correction. Partial-magnitude corrections optimized with an SPGD algorithm provide at least one line improvement of average visual acuity over the full magnitude and the correction by Guirao given the registration uncertainty. This study demonstrates that it is possible to improve the average visual acuity by optimizing wavefront-guided correction in the presence of registration uncertainty. PMID:23757512

  20. Video quality assessment method motivated by human visual perception

    NASA Astrophysics Data System (ADS)

    He, Meiling; Jiang, Gangyi; Yu, Mei; Song, Yang; Peng, Zongju; Shao, Feng

    2016-11-01

    Research on video quality assessment (VQA) plays a crucial role in improving the efficiency of video coding and the performance of video processing. It is well acknowledged that the motion energy model generates motion energy responses in a middle temporal area by simulating the receptive field of neurons in V1 for the motion perception of the human visual system. Motivated by the biological evidence for the visual motion perception, a VQA method is proposed in this paper, which comprises the motion perception quality index and the spatial index. To be more specific, the motion energy model is applied to evaluate the temporal distortion severity of each frequency component generated from the difference of Gaussian filter bank, which produces the motion perception quality index, and the gradient similarity measure is used to evaluate the spatial distortion of the video sequence to get the spatial quality index. The experimental results of the LIVE, CSIQ, and IVP video databases demonstrate that the random forests regression technique trained by the generated quality indices is highly correspondent to human visual perception and has many significant improvements than comparable well-performing methods. The proposed method has higher consistency with subjective perception and higher generalization capability.

  1. EAPhy: A Flexible Tool for High-throughput Quality Filtering of Exon-alignments and Data Processing for Phylogenetic Methods.

    PubMed

    Blom, Mozes P K

    2015-08-05

    Recently developed molecular methods enable geneticists to target and sequence thousands of orthologous loci and infer evolutionary relationships across the tree of life. Large numbers of genetic markers benefit species tree inference but visual inspection of alignment quality, as traditionally conducted, is challenging with thousands of loci. Furthermore, due to the impracticality of repeated visual inspection with alternative filtering criteria, the potential consequences of using datasets with different degrees of missing data remain nominally explored in most empirical phylogenomic studies. In this short communication, I describe a flexible high-throughput pipeline designed to assess alignment quality and filter exonic sequence data for subsequent inference. The stringency criteria for alignment quality and missing data can be adapted based on the expected level of sequence divergence. Each alignment is automatically evaluated based on the stringency criteria specified, significantly reducing the number of alignments that require visual inspection. By developing a rapid method for alignment filtering and quality assessment, the consistency of phylogenetic estimation based on exonic sequence alignments can be further explored across distinct inference methods, while accounting for different degrees of missing data.

  2. Visualization of Discontinuous Galerkin Based High-Order Methods

    DTIC Science & Technology

    2015-08-19

    function and the reference- to physical- space mapping functions. This formulation can be used to measure the quality of a high-order element and also for...to physical- space mapping functions. This formulation can be used to measure the quality of a high-order element and also for AMR. We find that the

  3. Immersive Molecular Visualization with Omnidirectional Stereoscopic Ray Tracing and Remote Rendering

    PubMed Central

    Stone, John E.; Sherman, William R.; Schulten, Klaus

    2016-01-01

    Immersive molecular visualization provides the viewer with intuitive perception of complex structures and spatial relationships that are of critical interest to structural biologists. The recent availability of commodity head mounted displays (HMDs) provides a compelling opportunity for widespread adoption of immersive visualization by molecular scientists, but HMDs pose additional challenges due to the need for low-latency, high-frame-rate rendering. State-of-the-art molecular dynamics simulations produce terabytes of data that can be impractical to transfer from remote supercomputers, necessitating routine use of remote visualization. Hardware-accelerated video encoding has profoundly increased frame rates and image resolution for remote visualization, however round-trip network latencies would cause simulator sickness when using HMDs. We present a novel two-phase rendering approach that overcomes network latencies with the combination of omnidirectional stereoscopic progressive ray tracing and high performance rasterization, and its implementation within VMD, a widely used molecular visualization and analysis tool. The new rendering approach enables immersive molecular visualization with rendering techniques such as shadows, ambient occlusion lighting, depth-of-field, and high quality transparency, that are particularly helpful for the study of large biomolecular complexes. We describe ray tracing algorithms that are used to optimize interactivity and quality, and we report key performance metrics of the system. The new techniques can also benefit many other application domains. PMID:27747138

  4. FISH Oracle 2: a web server for integrative visualization of genomic data in cancer research

    PubMed Central

    2014-01-01

    Background A comprehensive view on all relevant genomic data is instrumental for understanding the complex patterns of molecular alterations typically found in cancer cells. One of the most effective ways to rapidly obtain an overview of genomic alterations in large amounts of genomic data is the integrative visualization of genomic events. Results We developed FISH Oracle 2, a web server for the interactive visualization of different kinds of downstream processed genomics data typically available in cancer research. A powerful search interface and a fast visualization engine provide a highly interactive visualization for such data. High quality image export enables the life scientist to easily communicate their results. A comprehensive data administration allows to keep track of the available data sets. We applied FISH Oracle 2 to published data and found evidence that, in colorectal cancer cells, the gene TTC28 may be inactivated in two different ways, a fact that has not been published before. Conclusions The interactive nature of FISH Oracle 2 and the possibility to store, select and visualize large amounts of downstream processed data support life scientists in generating hypotheses. The export of high quality images supports explanatory data visualization, simplifying the communication of new biological findings. A FISH Oracle 2 demo server and the software is available at http://www.zbh.uni-hamburg.de/fishoracle. PMID:24684958

  5. High-quality compressive ghost imaging

    NASA Astrophysics Data System (ADS)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  6. CellProfiler Tracer: exploring and validating high-throughput, time-lapse microscopy image data.

    PubMed

    Bray, Mark-Anthony; Carpenter, Anne E

    2015-11-04

    Time-lapse analysis of cellular images is an important and growing need in biology. Algorithms for cell tracking are widely available; what researchers have been missing is a single open-source software package to visualize standard tracking output (from software like CellProfiler) in a way that allows convenient assessment of track quality, especially for researchers tuning tracking parameters for high-content time-lapse experiments. This makes quality assessment and algorithm adjustment a substantial challenge, particularly when dealing with hundreds of time-lapse movies collected in a high-throughput manner. We present CellProfiler Tracer, a free and open-source tool that complements the object tracking functionality of the CellProfiler biological image analysis package. Tracer allows multi-parametric morphological data to be visualized on object tracks, providing visualizations that have already been validated within the scientific community for time-lapse experiments, and combining them with simple graph-based measures for highlighting possible tracking artifacts. CellProfiler Tracer is a useful, free tool for inspection and quality control of object tracking data, available from http://www.cellprofiler.org/tracer/.

  7. Implementation of dictionary pair learning algorithm for image quality improvement

    NASA Astrophysics Data System (ADS)

    Vimala, C.; Aruna Priya, P.

    2018-04-01

    This paper proposes an image denoising on dictionary pair learning algorithm. Visual information is transmitted in the form of digital images is becoming a major method of communication in the modern age, but the image obtained after transmissions is often corrupted with noise. The received image needs processing before it can be used in applications. Image denoising involves the manipulation of the image data to produce a visually high quality image.

  8. A Regression-Based Family of Measures for Full-Reference Image Quality Assessment

    NASA Astrophysics Data System (ADS)

    Oszust, Mariusz

    2016-12-01

    The advances in the development of imaging devices resulted in the need of an automatic quality evaluation of displayed visual content in a way that is consistent with human visual perception. In this paper, an approach to full-reference image quality assessment (IQA) is proposed, in which several IQA measures, representing different approaches to modelling human visual perception, are efficiently combined in order to produce objective quality evaluation of examined images, which is highly correlated with evaluation provided by human subjects. In the paper, an optimisation problem of selection of several IQA measures for creating a regression-based IQA hybrid measure, or a multimeasure, is defined and solved using a genetic algorithm. Experimental evaluation on four largest IQA benchmarks reveals that the multimeasures obtained using the proposed approach outperform state-of-the-art full-reference IQA techniques, including other recently developed fusion approaches.

  9. Potential future impacts on visual air quality for Class I areas

    Treesearch

    Gurule Nochumson; Mona J. Wecksung

    1979-01-01

    Visual air quality is most sensitive to degradation by air pollution in areas with good visibility. The protection of visual air quality in mandatory Class I Federal areas has been declared a national goal by Congress. Impacts on visual air quality are calculated for 154 Class I areas where visual air quality is considered an important value. These impacts are...

  10. Comparison of vision through surface modulated and spatial light modulated multifocal optics.

    PubMed

    Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana

    2017-04-01

    Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near.

  11. Comparison of vision through surface modulated and spatial light modulated multifocal optics

    PubMed Central

    Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana

    2017-01-01

    Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near. PMID:28736655

  12. Standardizing Quality Assessment of Fused Remotely Sensed Images

    NASA Astrophysics Data System (ADS)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  13. Naturalness and interestingness of test images for visual quality evaluation

    NASA Astrophysics Data System (ADS)

    Halonen, Raisa; Westman, Stina; Oittinen, Pirkko

    2011-01-01

    Balanced and representative test images are needed to study perceived visual quality in various application domains. This study investigates naturalness and interestingness as image quality attributes in the context of test images. Taking a top-down approach we aim to find the dimensions which constitute naturalness and interestingness in test images and the relationship between these high-level quality attributes. We compare existing collections of test images (e.g. Sony sRGB images, ISO 12640 images, Kodak images, Nokia images and test images developed within our group) in an experiment combining quality sorting and structured interviews. Based on the data gathered we analyze the viewer-supplied criteria for naturalness and interestingness across image types, quality levels and judges. This study advances our understanding of subjective image quality criteria and enables the validation of current test images, furthering their development.

  14. Image gathering and digital restoration for fidelity and visual quality

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Alter-Gartenberg, Rachel; Rahman, Zia-Ur

    1991-01-01

    The fidelity and resolution of the traditional Wiener restorations given in the prevalent digital processing literature can be significantly improved when the transformations between the continuous and discrete representations in image gathering and display are accounted for. However, the visual quality of these improved restorations also is more sensitive to the defects caused by aliasing artifacts, colored noise, and ringing near sharp edges. In this paper, these visual defects are characterized, and methods for suppressing them are presented. It is demonstrated how the visual quality of fidelity-maximized images can be improved when (1) the image-gathering system is specifically designed to enhance the performance of the image-restoration algorithm, and (2) the Wiener filter is combined with interactive Gaussian smoothing, synthetic high edge enhancement, and nonlinear tone-scale transformation. The nonlinear transformation is used primarily to enhance the spatial details that are often obscurred when the normally wide dynamic range of natural radiance fields is compressed into the relatively narrow dynamic range of film and other displays.

  15. Image Fusion Algorithms Using Human Visual System in Transform Domain

    NASA Astrophysics Data System (ADS)

    Vadhi, Radhika; Swamy Kilari, Veera; Samayamantula, Srinivas Kumar

    2017-08-01

    The endeavor of digital image fusion is to combine the important visual parts from various sources to advance the visibility eminence of the image. The fused image has a more visual quality than any source images. In this paper, the Human Visual System (HVS) weights are used in the transform domain to select appropriate information from various source images and then to attain a fused image. In this process, mainly two steps are involved. First, apply the DWT to the registered source images. Later, identify qualitative sub-bands using HVS weights. Hence, qualitative sub-bands are selected from different sources to form high quality HVS based fused image. The quality of the HVS based fused image is evaluated with general fusion metrics. The results show the superiority among the state-of-the art resolution Transforms (MRT) such as Discrete Wavelet Transform (DWT), Stationary Wavelet Transform (SWT), Contourlet Transform (CT), and Non Sub Sampled Contourlet Transform (NSCT) using maximum selection fusion rule.

  16. Novel Integration of Frame Rate Up Conversion and HEVC Coding Based on Rate-Distortion Optimization.

    PubMed

    Guo Lu; Xiaoyun Zhang; Li Chen; Zhiyong Gao

    2018-02-01

    Frame rate up conversion (FRUC) can improve the visual quality by interpolating new intermediate frames. However, high frame rate videos by FRUC are confronted with more bitrate consumption or annoying artifacts of interpolated frames. In this paper, a novel integration framework of FRUC and high efficiency video coding (HEVC) is proposed based on rate-distortion optimization, and the interpolated frames can be reconstructed at encoder side with low bitrate cost and high visual quality. First, joint motion estimation (JME) algorithm is proposed to obtain robust motion vectors, which are shared between FRUC and video coding. What's more, JME is embedded into the coding loop and employs the original motion search strategy in HEVC coding. Then, the frame interpolation is formulated as a rate-distortion optimization problem, where both the coding bitrate consumption and visual quality are taken into account. Due to the absence of original frames, the distortion model for interpolated frames is established according to the motion vector reliability and coding quantization error. Experimental results demonstrate that the proposed framework can achieve 21% ~ 42% reduction in BDBR, when compared with the traditional methods of FRUC cascaded with coding.

  17. Interaction of aberrations, diffraction, and quantal fluctuations determine the impact of pupil size on visual quality.

    PubMed

    Xu, Renfeng; Wang, Huachun; Thibos, Larry N; Bradley, Arthur

    2017-04-01

    Our purpose is to develop a computational approach that jointly assesses the impact of stimulus luminance and pupil size on visual quality. We compared traditional optical measures of image quality and those that incorporate the impact of retinal illuminance dependent neural contrast sensitivity. Visually weighted image quality was calculated for a presbyopic model eye with representative levels of chromatic and monochromatic aberrations as pupil diameter was varied from 7 to 1 mm, stimulus luminance varied from 2000 to 0.1  cd/m2, and defocus varied from 0 to -2 diopters. The model included the effects of quantal fluctuations on neural contrast sensitivity. We tested the model's predictions for five cycles per degree gratings by measuring contrast sensitivity at 5  cyc/deg. Unlike the traditional Strehl ratio and the visually weighted area under the modulation transfer function, the visual Strehl ratio derived from the optical transfer function was able to capture the combined impact of optics and quantal noise on visual quality. In a well-focused eye, provided retinal illuminance is held constant as pupil size varies, visual image quality scales approximately as the square root of illuminance because of quantum fluctuations, but optimum pupil size is essentially independent of retinal illuminance and quantum fluctuations. Conversely, when stimulus luminance is held constant (and therefore illuminance varies with pupil size), optimum pupil size increases as luminance decreases, thereby compensating partially for increased quantum fluctuations. However, in the presence of -1 and -2 diopters of defocus and at high photopic levels where Weber's law operates, optical aberrations and diffraction dominate image quality and pupil optimization. Similar behavior was observed in human observers viewing sinusoidal gratings. Optimum pupil size increases as stimulus luminance drops for the well-focused eye, and the benefits of small pupils for improving defocused image quality remain throughout the photopic and mesopic ranges. However, restricting pupils to <2  mm will cause significant reductions in the best focus vision at low photopic and mesopic luminances.

  18. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed Central

    Hastings, Gareth D.; Marsack, Jason D.; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A.

    2017-01-01

    Purpose To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Methods Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. Results For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ±SD was −0.06 ±0.04 with both refractions; dilated was −0.05 ±0.04 with the objective, and −0.05 ±0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. Conclusions A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. PMID:28370389

  19. How visual search relates to visual diagnostic performance: a narrative systematic review of eye-tracking research in radiology.

    PubMed

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J

    2017-08-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye tracking literature in radiology indicates several search patterns are related to high levels of expertise, but teaching novices to search as an expert may not be effective. Experimental research is needed to find out which search strategies can improve image perception in learners.

  20. Visual Enhancements: Improving Deaf Students' Transition Skills Using Multimedia Technology.

    ERIC Educational Resources Information Center

    Davis, Cheryl D.

    1999-01-01

    Discusses developments in technology that provide high-quality visual access to transition information and multimedia instruction for learners with deafness. Identifies a variety of considerations in using multimedia products and describes the pros and cons of different media in the context of several multimedia projects. (Author/CR)

  1. Managing the care of patients who have visual impairment.

    PubMed

    Watkinson, Sue; Scott, Eileen

    An ageing population means that the incidence of people who are visually impaired will increase. However, extending the role of ophthalmic nurses will promote delivery of a more effective health service for these patients. Using Maslow's hierarchy of needs as a basis for addressing the care of patients with visual impairment is a means of ensuring that they receive high quality, appropriate care at the right time.

  2. Visual air quality simulation techniques

    NASA Astrophysics Data System (ADS)

    Molenar, John V.; Malm, William C.; Johnson, Christopher E.

    Visual air quality is primarily a human perceptual phenomenon beginning with the transfer of image-forming information through an illuminated, scattering and absorbing atmosphere. Visibility, especially the visual appearance of industrial emissions or the degradation of a scenic view, is the principal atmospheric characteristic through which humans perceive air pollution, and is more sensitive to changing pollution levels than any other air pollution effect. Every attempt to quantify economic costs and benefits of air pollution has indicated that good visibility is a highly valued and desired environmental condition. Measurement programs can at best approximate the state of the ambient atmosphere at a few points in a scenic vista viewed by an observer. To fully understand the visual effect of various changes in the concentration and distribution of optically important atmospheric pollutants requires the use of aerosol and radiative transfer models. Communication of the output of these models to scientists, decision makers and the public is best done by applying modern image-processing systems to generate synthetic images representing the modeled air quality conditions. This combination of modeling techniques has been under development for the past 15 yr. Initially, visual air quality simulations were limited by a lack of computational power to simplified models depicting Gaussian plumes or uniform haze conditions. Recent explosive growth in low cost, high powered computer technology has allowed the development of sophisticated aerosol and radiative transfer models that incorporate realistic terrain, multiple scattering, non-uniform illumination, varying spatial distribution, concentration and optical properties of atmospheric constituents, and relative humidity effects on aerosol scattering properties. This paper discusses these improved models and image-processing techniques in detail. Results addressing uniform and non-uniform layered haze conditions in both urban and remote pristine areas will be presented.

  3. Automated daily quality control analysis for mammography in a multi-unit imaging center.

    PubMed

    Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli

    2018-01-01

    Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

  4. Quality of life in patients with visual impairment in Ibadan: a clinical study in primary care.

    PubMed

    Adigun, Kehinde; Oluleye, Tunji S; Ladipo, Modupe Ma; Olowookere, Samuel Anu

    2014-01-01

    Visual function is important for optimal orientation in functional and social life, and has an effect on physical and emotional well-being. Visual impairment, therefore, leads to restrictions in all aspects of daily living and is related to quality of life. The aim of this study was to provide information on the causes of visual impairment in patients presenting to their family physician, the spectrum of impairment, and its impact on quality of life for these patients. This descriptive cross-sectional study of 375 adult patients with ocular symptoms was performed in the general outpatient department of the University College Hospital, Ibadan, from July to September, 2009. After checking their presenting visual acuity, the patients were interviewed using the Vision-Related Quality of Life questionnaire to determine the impact of visual impairment on their quality of life. Ophthalmic examinations were performed to determine the causes of visual impairment. The results were analyzed using proportions and percentages. The main causes of visual impairment were cataracts (58.7%), refractive error (19.4%), and glaucoma (2.9%). Visual impairment was found to be associated with advancing age, low education, and unemployment (P<0.001). Most patients (85.1%) were found to have good quality of life overall. Quality of life was found to be poor in the domains of visual function (64.2%) and social interaction (50.9%). Quality of life was found to be related to the degree of visual impairment, ie, blind patients reported poor quality of life (41.4%) when compared with those having low vision (8.6%) or near normal vision (2.4%, P<0.001). This study identified poor quality of life in patients with a higher degree of visual impairment. Family physicians need to identify these visually impaired patients early and make timely referrals.

  5. Preparation of wholemount mouse intestine for high-resolution three-dimensional imaging using two-photon microscopy.

    PubMed

    Appleton, P L; Quyn, A J; Swift, S; Näthke, I

    2009-05-01

    Visualizing overall tissue architecture in three dimensions is fundamental for validating and integrating biochemical, cell biological and visual data from less complex systems such as cultured cells. Here, we describe a method to generate high-resolution three-dimensional image data of intact mouse gut tissue. Regions of highest interest lie between 50 and 200 mum within this tissue. The quality and usefulness of three-dimensional image data of tissue with such depth is limited owing to problems associated with scattered light, photobleaching and spherical aberration. Furthermore, the highest-quality oil-immersion lenses are designed to work at a maximum distance of

  6. Towards a Visual Quality Metric for Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    1998-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  7. Automated Assessment of Visual Quality of Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Ellis, Stephen R. (Technical Monitor)

    1997-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images[1-4]. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  8. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    PubMed

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  9. GPU accelerated optical coherence tomography angiography using strip-based registration (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Heisler, Morgan; Lee, Sieun; Mammo, Zaid; Jian, Yifan; Ju, Myeong Jin; Miao, Dongkai; Raposo, Eric; Wahl, Daniel J.; Merkur, Andrew; Navajas, Eduardo; Balaratnasingam, Chandrakumar; Beg, Mirza Faisal; Sarunic, Marinko V.

    2017-02-01

    High quality visualization of the retinal microvasculature can improve our understanding of the onset and development of retinal vascular diseases, which are a major cause of visual morbidity and are increasing in prevalence. Optical Coherence Tomography Angiography (OCT-A) images are acquired over multiple seconds and are particularly susceptible to motion artifacts, which are more prevalent when imaging patients with pathology whose ability to fixate is limited. The acquisition of multiple OCT-A images sequentially can be performed for the purpose of removing motion artifact and increasing the contrast of the vascular network through averaging. Due to the motion artifacts, a robust registration pipeline is needed before feature preserving image averaging can be performed. In this report, we present a novel method for a GPU-accelerated pipeline for acquisition, processing, segmentation, and registration of multiple, sequentially acquired OCT-A images to correct for the motion artifacts in individual images for the purpose of averaging. High performance computing, blending CPU and GPU, was introduced to accelerate processing in order to provide high quality visualization of the retinal microvasculature and to enable a more accurate quantitative analysis in a clinically useful time frame. Specifically, image discontinuities caused by rapid micro-saccadic movements and image warping due to smoother reflex movements were corrected by strip-wise affine registration estimated using Scale Invariant Feature Transform (SIFT) keypoints and subsequent local similarity-based non-rigid registration. These techniques improve the image quality, increasing the value for clinical diagnosis and increasing the range of patients for whom high quality OCT-A images can be acquired.

  10. High resolution renderings and interactive visualization of the 2006 Huntington Beach experiment

    NASA Astrophysics Data System (ADS)

    Im, T.; Nayak, A.; Keen, C.; Samilo, D.; Matthews, J.

    2006-12-01

    The Visualization Center at the Scripps Institution of Oceanography investigates innovative ways to represent graphically interactive 3D virtual landscapes and to produce high resolution, high quality renderings of Earth sciences data and the sensors and instruments used to collect the data . Among the Visualization Center's most recent work is the visualization of the Huntington Beach experiment, a study launched in July 2006 by the Southern California Ocean Observing System (http://www.sccoos.org/) to record and synthesize data of the Huntington Beach coastal region. Researchers and students at the Visualization Center created visual presentations that combine bathymetric data provided by SCCOOS with USGS aerial photography and with 3D polygonal models of sensors created in Maya into an interactive 3D scene using the Fledermaus suite of visualization tools (http://www.ivs3d.com). In addition, the Visualization Center has produced high definition (HD) animations of SCCOOS sensor instruments (e.g. REMUS, drifters, spray glider, nearshore mooring, OCSD/USGS mooring and CDIP mooring) using the Maya modeling and animation software and rendered over multiple nodes of the OptIPuter Visualization Cluster at Scripps. These visualizations are aimed at providing researchers with a broader context of sensor locations relative to geologic characteristics, to promote their use as an educational resource for informal education settings and increasing public awareness, and also as an aid for researchers' proposals and presentations. These visualizations are available for download on the Visualization Center website at http://siovizcenter.ucsd.edu/sccoos/hb2006.php.

  11. A system to program projects to meet visual quality objectives

    Treesearch

    Fred L. Henley; Frank L. Hunsaker

    1979-01-01

    The U. S. Forest Service has established Visual Quality Objectives for National Forest lands and determined a method to ascertain the Visual Absorption Capability of those lands. Combining the two mapping inventories has allowed the Forest Service to retain the visual quality while managing natural resources.

  12. Genome U-Plot: a whole genome visualization.

    PubMed

    Gaitatzes, Athanasios; Johnson, Sarah H; Smadbeck, James B; Vasmatzis, George

    2018-05-15

    The ability to produce and analyze whole genome sequencing (WGS) data from samples with structural variations (SV) generated the need to visualize such abnormalities in simplified plots. Conventional two-dimensional representations of WGS data frequently use either circular or linear layouts. There are several diverse advantages regarding both these representations, but their major disadvantage is that they do not use the two-dimensional space very efficiently. We propose a layout, termed the Genome U-Plot, which spreads the chromosomes on a two-dimensional surface and essentially quadruples the spatial resolution. We present the Genome U-Plot for producing clear and intuitive graphs that allows researchers to generate novel insights and hypotheses by visualizing SVs such as deletions, amplifications, and chromoanagenesis events. The main features of the Genome U-Plot are its layered layout, its high spatial resolution and its improved aesthetic qualities. We compare conventional visualization schemas with the Genome U-Plot using visualization metrics such as number of line crossings and crossing angle resolution measures. Based on our metrics, we improve the readability of the resulting graph by at least 2-fold, making apparent important features and making it easy to identify important genomic changes. A whole genome visualization tool with high spatial resolution and improved aesthetic qualities. An implementation and documentation of the Genome U-Plot is publicly available at https://github.com/gaitat/GenomeUPlot. vasmatzis.george@mayo.edu. Supplementary data are available at Bioinformatics online.

  13. Relationship of cataract symptoms of preoperative patients and vision-related quality of life.

    PubMed

    Lee, Jae Eun; Fos, Peter J; Sung, Jung Hye; Amy, Brian W; Zuniga, Miguel A; Lee, Won Jae; Kim, Jae Chang

    2005-10-01

    This study was conducted in an attempt to describe the status of cataract symptoms of preoperative cataract patients, as well as to determine the relationship between cataract symptom and vision-related quality of life measures. A cross-sectional study design was used. Study subjects were selected using non-probabilistic methods. The study sample consisted of 132 patients scheduled for cataract surgery in one eye. Information was obtained from study subjects by conducting face-to-face interviews. Study subjects were adult cataract patients at Samsung and Kunyang General Hospitals in Seoul, Korea, and Tulane University Hospital and Clinics in New Orleans, Louisiana, United States of America. Degree to which study subjects were "bothered" by cataract symptoms was measured by using the 5-item Cataract Symptom Scores (CSS). The number of symptoms, highest scored symptom among the five, number of symptoms extremely bothering, and the mean of cataract symptom score were created based on the CSS measure. Vision-related quality of life was assessed by using the Visual Function 14 Items (VF-14) and Global Measure of Vision (GMV) for trouble and satisfaction. The symptoms "blurry vision" and "worsening of vision" were most frequently reported. The symptom "colors looking different" was rarely reported among preoperative cataract patients. The degree to which study subjects were bothered by "blurry vision" and "seeing glare, halo, or rings" was highly associated with visual function, visual trouble, and visual satisfaction. Multiple regression analysis revealed that the newly developed cataract symptom-related scales, as well as total amount of degree to which study subjects were "bothered" by symptoms were highly related to vision-related quality of life measures. These relationships were persistent after controlling for major socio-demographic variables. The results indicate that cataract symptoms are highly associated with vision-related quality of life. The results also suggest that the number of symptoms, highest scored symptom among the five, number of symptoms extremely bothering, and the mean cataract symptom scores should be considered an important cataract symptom-related scale when analyzing quality of life, including cataract symptom.

  14. Real-time phase-contrast x-ray imaging: a new technique for the study of animal form and function

    PubMed Central

    Socha, John J; Westneat, Mark W; Harrison, Jon F; Waters, James S; Lee, Wah-Keat

    2007-01-01

    Background Despite advances in imaging techniques, real-time visualization of the structure and dynamics of tissues and organs inside small living animals has remained elusive. Recently, we have been using synchrotron x-rays to visualize the internal anatomy of millimeter-sized opaque, living animals. This technique takes advantage of partially-coherent x-rays and diffraction to enable clear visualization of internal soft tissue not viewable via conventional absorption radiography. However, because higher quality images require greater x-ray fluxes, there exists an inherent tradeoff between image quality and tissue damage. Results We evaluated the tradeoff between image quality and harm to the animal by determining the impact of targeted synchrotron x-rays on insect physiology, behavior and survival. Using 25 keV x-rays at a flux density of 80 μW/mm-2, high quality video-rate images can be obtained without major detrimental effects on the insects for multiple minutes, a duration sufficient for many physiological studies. At this setting, insects do not heat up. Additionally, we demonstrate the range of uses of synchrotron phase-contrast imaging by showing high-resolution images of internal anatomy and observations of labeled food movement during ingestion and digestion. Conclusion Synchrotron x-ray phase contrast imaging has the potential to revolutionize the study of physiology and internal biomechanics in small animals. This is the only generally applicable technique that has the necessary spatial and temporal resolutions, penetrating power, and sensitivity to soft tissue that is required to visualize the internal physiology of living animals on the scale from millimeters to microns. PMID:17331247

  15. Teaching Macroeconomics to the Visually Impaired: New Tactile Methods, Verbal Precision, and Small Groups

    ERIC Educational Resources Information Center

    Naples, Michele I.

    2017-01-01

    Visually-impaired students require tailored pedagogies to ensure their instruction is as high quality as for sighted students. They follow board work during class by referring to typed class notes provided ahead of time via a Braille reader, and in-class small groups solving problems create an inclusive "esprit de corps" and promote…

  16. Color visual simulation applications at the Defense Mapping Agency

    NASA Astrophysics Data System (ADS)

    Simley, J. D.

    1984-09-01

    The Defense Mapping Agency (DMA) produces the Digital Landmass System data base to provide culture and terrain data in support of numerous aircraft simulators. In order to conduct data base and simulation quality control and requirements analysis, DMA has developed the Sensor Image Simulator which can rapidly generate visual and radar static scene digital simulations. The use of color in visual simulation allows the clear portrayal of both landcover and terrain data, whereas the initial black and white capabilities were restricted in this role and thus found limited use. Color visual simulation has many uses in analysis to help determine the applicability of current and prototype data structures to better meet user requirements. Color visual simulation is also significant in quality control since anomalies can be more easily detected in natural appearing forms of the data. The realism and efficiency possible with advanced processing and display technology, along with accurate data, make color visual simulation a highly effective medium in the presentation of geographic information. As a result, digital visual simulation is finding increased potential as a special purpose cartographic product. These applications are discussed and related simulation examples are presented.

  17. Scenario-visualization for the assessment of perceived green space qualities at the urban-rural fringe.

    PubMed

    Lange, Eckart; Hehl-Lange, Sigrid; Brewer, Mark J

    2008-11-01

    The provision of green space is increasingly being perceived as an important factor for quality of life. However, green spaces often face high developmental pressure. The main objective of this study is to investigate a prospective approach to green space planning by combining three-dimensional (3D) visualization of green space scenarios and survey techniques to facilitate improved participation of the public. Aside from the 'Status quo', scenarios 'Agriculture', 'Recreation', 'Nature conservation' and 'Wind turbines' are visualized in three dimensions. In order to test responses, a survey was conducted both in print format and on the Internet. Overall, 49 different visualizations that belong to one of the scenarios were available in the survey and were rated according to the perceived esthetic, recreational and ecological values. The highest rated scenes include vegetation elements such as meadows with orchards, single trees, shrubs or forest. The least attractive scenes are those where buildings are highly dominant or where there are no vegetation elements. Based on the ratings for the individual images and on the corresponding scenarios, our study shows that there is high potential for improving the existing landscape. All suggested changes are either rated about equal to or considerably higher than the status quo, with the scenario 'Nature conservation' receiving the highest scores.

  18. The Effect of Image Quality, Repeated Study, and Assessment Method on Anatomy Learning

    ERIC Educational Resources Information Center

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A.; Wainman, Bruce C.

    2017-01-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality…

  19. Large-Scale Point-Cloud Visualization through Localized Textured Surface Reconstruction.

    PubMed

    Arikan, Murat; Preiner, Reinhold; Scheiblauer, Claus; Jeschke, Stefan; Wimmer, Michael

    2014-09-01

    In this paper, we introduce a novel scene representation for the visualization of large-scale point clouds accompanied by a set of high-resolution photographs. Many real-world applications deal with very densely sampled point-cloud data, which are augmented with photographs that often reveal lighting variations and inaccuracies in registration. Consequently, the high-quality representation of the captured data, i.e., both point clouds and photographs together, is a challenging and time-consuming task. We propose a two-phase approach, in which the first (preprocessing) phase generates multiple overlapping surface patches and handles the problem of seamless texture generation locally for each patch. The second phase stitches these patches at render-time to produce a high-quality visualization of the data. As a result of the proposed localization of the global texturing problem, our algorithm is more than an order of magnitude faster than equivalent mesh-based texturing techniques. Furthermore, since our preprocessing phase requires only a minor fraction of the whole data set at once, we provide maximum flexibility when dealing with growing data sets.

  20. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed

    Hastings, Gareth D; Marsack, Jason D; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A

    2017-05-01

    To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ± S.D. was -0.06 ± 0.04 with both refractions; dilated was -0.05 ± 0.04 with the objective, and -0.05 ± 0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  1. Video quality assessment using motion-compensated temporal filtering and manifold feature similarity

    PubMed Central

    Yu, Mei; Jiang, Gangyi; Shao, Feng; Peng, Zongju

    2017-01-01

    Well-performed Video quality assessment (VQA) method should be consistent with human visual systems for better prediction accuracy. In this paper, we propose a VQA method using motion-compensated temporal filtering (MCTF) and manifold feature similarity. To be more specific, a group of frames (GoF) is first decomposed into a temporal high-pass component (HPC) and a temporal low-pass component (LPC) by MCTF. Following this, manifold feature learning (MFL) and phase congruency (PC) are used to predict the quality of temporal LPC and temporal HPC respectively. The quality measures of the LPC and the HPC are then combined as GoF quality. A temporal pooling strategy is subsequently used to integrate GoF qualities into an overall video quality. The proposed VQA method appropriately processes temporal information in video by MCTF and temporal pooling strategy, and simulate human visual perception by MFL. Experiments on publicly available video quality database showed that in comparison with several state-of-the-art VQA methods, the proposed VQA method achieves better consistency with subjective video quality and can predict video quality more accurately. PMID:28445489

  2. Human visual system consistent quality assessment for remote sensing image fusion

    NASA Astrophysics Data System (ADS)

    Liu, Jun; Huang, Junyi; Liu, Shuguang; Li, Huali; Zhou, Qiming; Liu, Junchen

    2015-07-01

    Quality assessment for image fusion is essential for remote sensing application. Generally used indices require a high spatial resolution multispectral (MS) image for reference, which is not always readily available. Meanwhile, the fusion quality assessments using these indices may not be consistent with the Human Visual System (HVS). As an attempt to overcome this requirement and inconsistency, this paper proposes an HVS-consistent image fusion quality assessment index at the highest resolution without a reference MS image using Gaussian Scale Space (GSS) technology that could simulate the HVS. The spatial details and spectral information of original and fused images are first separated in GSS, and the qualities are evaluated using the proposed spatial and spectral quality index respectively. The overall quality is determined without a reference MS image by a combination of the proposed two indices. Experimental results on various remote sensing images indicate that the proposed index is more consistent with HVS evaluation compared with other widely used indices that may or may not require reference images.

  3. Effects of multifocal soft contact lenses used to slow myopia progression on quality of vision in young adults.

    PubMed

    Kang, Pauline; McAlinden, Colm; Wildsoet, Christine F

    2017-02-01

    To assess the effects of multifocal soft contact lenses (MF SCLs) used for myopia control on visual acuity (VA) and subjective quality of vision. Twenty-four young adult myopes had baseline high and low-contrast VAs and refractions measured and quality of vision assessed by the Quality of Vision (QoV) questionnaire with single vision SCLs. Additional VA and QoV questionnaire data were collected immediately after subjects were fitted with Proclear MF SCLs and again after a 2-week adaptation period of daily lens wear. Data were collected for two MF SCL designs, incorporating +1.50 and +3.00 D peripheral near additions, with a week washout period allowed between the two lens trials. High- and low-contrast VAs were initially reduced with both MF SCL designs, but subsequently improved to be not significantly reduced in the case of high-contrast VA by the end of the 2-week adaptation period. The quality of vision was also reduced, more so with the +3.00 D MF SCL. Quality of Vision (QoV) scores describing frequency, severity and bothersome nature of visual symptoms indicated symptoms worsening rather than resolving over the 2-week period, particularly so with the +3.00 D MF SCL. Low and high add MF SCLs adversely affected vision on initial insertion, with sustained effects on low-contrast VA and QoV scores but not high-contrast VA. Thus, high-contrast VA is not a suitable surrogate for quality of vision. In prescribing MF SCLs for myopia control, clinicians should educate patients about these effects on vision. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. The prediction of leather mechanical properties from airborne ultrasonic testing of hides

    USDA-ARS?s Scientific Manuscript database

    High quality, clean, and well-preserved hides are paramount for competitiveness in both domestic and export markets. Currently, hides are visually inspected and ranked for quality and sale price, which is not reliable when hair is present on the hides. Advanced technologies are needed to nondestru...

  5. PERSPECTIVE: Is acuity enough? Other considerations in clinical investigations of visual prostheses

    NASA Astrophysics Data System (ADS)

    Lepri, Bernard P.

    2009-06-01

    Visual impairing eye diseases are the major frontier facing ophthalmic research today in light of our rapidly aging population. The visual skills necessary for improving the quality of daily function and life are inextricably linked to these impairing diseases. Both research and reimbursement programs are emphasizing outcome-based results. Is improvement in visual acuity alone enough to improve the function and quality of life of visually impaired persons? This perspective summarizes the types of effectiveness endpoints for clinical investigations of visual prostheses that go beyond visual acuity. The clinical investigation of visual prostheses should include visual function, functional vision and quality of life measures. Specifically, they encompass contrast sensitivity, orientation and mobility, activities of daily living and quality of life assessments. The perspective focuses on the design of clinical trials for visual prostheses and the methods of determining effectiveness above and beyond visual acuity that will yield outcomes that are measured by improved function in the visual world and quality of life. The visually impaired population is the primary consideration in this presentation with particular emphases on retinitis pigmentosa and age-related macular degeneration. Clinical trials for visual prostheses cannot be isolated from the need for medical rehabilitation in order to obtain measurements of effectiveness that produce outcomes/evidence-based success. This approach will facilitate improvement in daily function and quality of life of patients with diseases that cause chronic vision impairment. The views and opinions are those of the author and do not necessarily reflect those of the US Food and Drug Administration, the US Department of Health and Human Services or the Public Health Service.

  6. Visualization for genomics: the Microbial Genome Viewer.

    PubMed

    Kerkhoven, Robert; van Enckevort, Frank H J; Boekhorst, Jos; Molenaar, Douwe; Siezen, Roland J

    2004-07-22

    A Web-based visualization tool, the Microbial Genome Viewer, is presented that allows the user to combine complex genomic data in a highly interactive way. This Web tool enables the interactive generation of chromosome wheels and linear genome maps from genome annotation data stored in a MySQL database. The generated images are in scalable vector graphics (SVG) format, which is suitable for creating high-quality scalable images and dynamic Web representations. Gene-related data such as transcriptome and time-course microarray experiments can be superimposed on the maps for visual inspection. The Microbial Genome Viewer 1.0 is freely available at http://www.cmbi.kun.nl/MGV

  7. Simulation Study of Impact of Aeroelastic Characteristics on Flying Qualities of a High Speed Civil Transport

    NASA Technical Reports Server (NTRS)

    Raney, David L.; Jackson, E. Bruce; Buttrill, Carey S.

    2002-01-01

    A piloted simulation study conducted in NASA Langley Visual Motion Simulator addressed the impact of dynamic aero- servoelastic effects on flying qualities of a High Speed Civil Transport. The intent was to determine effectiveness of measures to reduce the impact of aircraft flexibility on piloting tasks. Potential solutions examined were increasing frequency of elastic modes through structural stiffening, increasing damping of elastic modes through active control, elimination of control effector excitation of the lowest frequency elastic modes, and elimination of visual cues associated with elastic modes. Six test pilots evaluated and performed simulated maneuver tasks, encountering incidents wherein cockpit vibrations due to elastic modes fed back into the control stick through involuntary vibrations of the pilots upper body and arm. Structural stiffening and compensation of the visual display were of little benefit in alleviating this impact, while increased damping and elimination of control effector excitation of the elastic modes both offered great improvements when applied in sufficient degree.

  8. Special Issue of Selected Papers from Visualization and Data Analysis 2011

    NASA Technical Reports Server (NTRS)

    Kao, David L.; Wong, Pak Chung

    2012-01-01

    This special issue features the best papers that were selected from the 18th SPIE Conference on Visualization and Data Analysis (VDA 2011). This annual conference is a major international forum for researchers and practitioners interested in data visualization and analytics research, development, and applications. VDA 2011 received 42 high-quality submissions from around the world. Twenty-four papers were selected for full conference papers. The top five papers have been expanded and reviewed for this special issue.

  9. Key factors for a high-quality VR experience

    NASA Astrophysics Data System (ADS)

    Champel, Mary-Luc; Doré, Renaud; Mollet, Nicolas

    2017-09-01

    For many years, Virtual Reality has been presented as a promising technology that could deliver a truly new experience to users. The media and entertainment industry is now investigating the possibility to offer a video-based VR 360 experience. Nevertheless, there is a substantial risk that VR 360 could have the same fate as 3DTV if it cannot offer more than just being the next fad. The present paper aims at presenting the various quality factors required for a high-quality VR experience. More specifically, this paper will focus on the main three VR quality pillars: visual, audio and immersion.

  10. Introduction of 3D Printing Technology in the Classroom for Visually Impaired Students

    ERIC Educational Resources Information Center

    Jo, Wonjin; I, Jang Hee; Harianto, Rachel Ananda; So, Ji Hyun; Lee, Hyebin; Lee, Heon Ju; Moon, Myoung-Woon

    2016-01-01

    The authors investigate how 3D printing technology could be utilized for instructional materials that allow visually impaired students to have full access to high-quality instruction in history class. Researchers from the 3D Printing Group of the Korea Institute of Science and Technology (KIST) provided the Seoul National School for the Blind with…

  11. Visual and x-ray inspection characteristics of eutectic and lead free assemblies

    NASA Technical Reports Server (NTRS)

    Ghaffarian, R.

    2003-01-01

    For high reliability applications, visual inspection has been the key technique for most conventional electronic package assemblies. Now, the use of x-ray technique has become an additional inspection requirement for quality control and detection of unique defects due to manufacturing of advanced electronic array packages such as ball grid array (BGAs) and chip scale packages (CSPs).

  12. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration

    PubMed Central

    Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W.; Jackson, Mary Lou

    2018-01-01

    Purpose Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. Methods We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Results Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). Conclusion In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL. PMID:29746512

  13. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration.

    PubMed

    Roh, Miin; Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W; Jackson, Mary Lou

    2018-01-01

    Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL.

  14. Neonatal hemodynamic response to visual cortex activity: high-density near-infrared spectroscopy study

    NASA Astrophysics Data System (ADS)

    Liao, Steve M.; Gregg, Nick M.; White, Brian R.; Zeff, Benjamin W.; Bjerkaas, Katelin A.; Inder, Terrie E.; Culver, Joseph P.

    2010-03-01

    The neurodevelopmental outcome of neonatal intensive care unit (NICU) infants is a major clinical concern with many infants displaying neurobehavioral deficits in childhood. Functional neuroimaging may provide early recognition of neural deficits in high-risk infants. Near-infrared spectroscopy (NIRS) has the advantage of providing functional neuroimaging in infants at the bedside. However, limitations in traditional NIRS have included contamination from superficial vascular dynamics in the scalp. Furthermore, controversy exists over the nature of normal vascular, responses in infants. To address these issues, we extend the use of novel high-density NIRS arrays with multiple source-detector distances and a superficial signal regression technique to infants. Evaluations of healthy term-born infants within the first three days of life are performed without sedation using a visual stimulus. We find that the regression technique significantly improves brain activation signal quality. Furthermore, in six out of eight infants, both oxy- and total hemoglobin increases while deoxyhemoglobin decreases, suggesting that, at term, the neurovascular coupling in the visual cortex is similar to that found in healthy adults. These results demonstrate the feasibility of using high-density NIRS arrays in infants to improve signal quality through superficial signal regression, and provide a foundation for further development of high-density NIRS as a clinical tool.

  15. Vision-related Quality of Life in Korean Glaucoma Patients.

    PubMed

    Sung, Kyung Rim; Chun, Yeoun Sook; Park, Chan Kee; Kim, Hwang Ki; Yoo, Chungkwon; Kim, Yong Yeon; Park, Ki Ho; Kim, Chan Yun; Choi, Kyu-Ryong; Lee, Kyoo Won; Han, Seungbong; Kim, Chang-Sik

    2017-02-01

    The purpose of the study was to evaluate vision-related quality of life in Korean glaucoma patients and to explore the associated factors. A total of 907 glaucoma patients were recruited from the prospectively designed LIGHT (Life quality of the glaucoma patient who underwent treatment) study organized by the Korean Glaucoma Society. Basic questionnaire that included items related to socioeconomic status, comorbidity, and lifestyle, and the validated Korean version of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) were collected. The Rasch score, a logit-based interval scale estimate to summarizing the NEI VFQ-25 responses, was calculated. The univariate and multivariable regression models were used to evaluate associations between the Rasch score and variables. The mean patient age was 58.1±14.1 years, visual field mean deviation (VF MD) of the better and worse eyes was -4.92±6.14 and -9.77±8.31 dB, binocular-integrated VF (IVF) MD was -3.55±5.31 dB, respectively. The lower NEI VFQ-25 Rasch score showed a significant association with the presence of other ocular diseases (P=0.020), a high school level of education or less [vs. university (P=0.006), vs. graduate school or higher (P=0.019)], an anxious personality [vs. a moderate personality (P<0.001), vs. a relaxed personality (P<0.001)], the number of glaucoma medications in use (P=0.049), worse eye visual acuity (P<0.001), and IVF MD (P<0.001). Visual function parameters are important for the vision-related quality of life of Korean glaucoma patients, notably for worse eye visual acuity and IVF MD. However, social factors, self-assessed personality, and treatment-related issues are also substantial predictors of overall life quality.

  16. Use of images in shelf life assessment of fruit salad.

    PubMed

    Manzocco, Lara; Rumignani, Alberto; Lagazio, Corrado

    2012-07-01

    Fruit salads stored for different lengths of time as well as their images were used to estimate sensory shelf life by survival analysis. Shelf life estimates obtained using fruit salad images were longer than those achieved by analyzing the real product. This was attributed to the fact that images are 2-dimensional representations of real food, probably not comprehensive of all the visual information needed by the panelists to produce an acceptability/unacceptability judgment. Images were also subjected to image analysis and the analysis of the overall visual quality by a trained panel. These indices proved to be highly correlated to consumer rejection of the fruit salad and could be exploited for routine shelf life assessment of analogous products. To this regard, a failure criterion of 25% consumer rejection could be equivalent to a score 3 in a 5-point overall visual quality scale. Food images can be used to assess product shelf life. In the case of fruit salads, the overall visual quality assessed by a trained panel on product images and the percentage of brown pixels in digital images can be exploited to estimate shelf life corresponding to a selected consumer rejection. © 2012 Institute of Food Technologists®

  17. Communicating data quality through Web Map Services

    NASA Astrophysics Data System (ADS)

    Blower, Jon; Roberts, Charles; Griffiths, Guy; Lewis, Jane; Yang, Kevin

    2013-04-01

    The sharing and visualization of environmental data through spatial data infrastructures is becoming increasingly common. However, information about the quality of data is frequently unavailable or presented in an inconsistent fashion. ("Data quality" is a phrase with many possible meanings but here we define it as "fitness for purpose" - therefore different users have different notions of what constitutes a "high quality" dataset.) The GeoViQua project (www.geoviqua.org) is developing means for eliciting, formatting, discovering and visualizing quality information using ISO and Open Geospatial Consortium (OGC) standards. Here we describe one aspect of the innovations of the GeoViQua project. In this presentation, we shall demonstrate new developments in using Web Map Services to communicate data quality at the level of datasets, variables and individual samples. We shall outline a new draft set of conventions (known as "WMS-Q"), which describe a set of rules for using WMS to convey quality information (OGC draft Engineering Report 12-160). We shall demonstrate these conventions through new prototype software, based upon the widely-used ncWMS software, that applies these rules to enable the visualization of uncertainties in raster data such as satellite products and the results of numerical simulations. Many conceptual and practical issues have arisen from these experiments. How can source data be formatted so that a WMS implementation can detect the semantic links between variables (e.g. the links between a mean field and its variance)? The visualization of uncertainty can be a complex task - how can we provide users with the power and flexibility to choose an optimal strategy? How can we maintain compatibility (as far as possible) with existing WMS clients? We explore these questions with reference to existing standards and approaches, including UncertML, NetCDF-U and Styled Layer Descriptors.

  18. Multiscale visual quality assessment for cluster analysis with self-organizing maps

    NASA Astrophysics Data System (ADS)

    Bernard, Jürgen; von Landesberger, Tatiana; Bremm, Sebastian; Schreck, Tobias

    2011-01-01

    Cluster analysis is an important data mining technique for analyzing large amounts of data, reducing many objects to a limited number of clusters. Cluster visualization techniques aim at supporting the user in better understanding the characteristics and relationships among the found clusters. While promising approaches to visual cluster analysis already exist, these usually fall short of incorporating the quality of the obtained clustering results. However, due to the nature of the clustering process, quality plays an important aspect, as for most practical data sets, typically many different clusterings are possible. Being aware of clustering quality is important to judge the expressiveness of a given cluster visualization, or to adjust the clustering process with refined parameters, among others. In this work, we present an encompassing suite of visual tools for quality assessment of an important visual cluster algorithm, namely, the Self-Organizing Map (SOM) technique. We define, measure, and visualize the notion of SOM cluster quality along a hierarchy of cluster abstractions. The quality abstractions range from simple scalar-valued quality scores up to the structural comparison of a given SOM clustering with output of additional supportive clustering methods. The suite of methods allows the user to assess the SOM quality on the appropriate abstraction level, and arrive at improved clustering results. We implement our tools in an integrated system, apply it on experimental data sets, and show its applicability.

  19. Scales of heterogeneity of water quality in rivers: Insights from high resolution maps based on integrated geospatial, sensor and ROV technologies

    EPA Science Inventory

    While the spatial heterogeneity of many aquatic ecosystems is acknowledged, rivers are often mistakenly described as homogenous and well-mixed. The collection and visualization of attributes like water quality is key to our perception and management of these ecosystems. The ass...

  20. From optics to attention: visual perception in barn owls.

    PubMed

    Harmening, Wolf M; Wagner, Hermann

    2011-11-01

    Barn owls are nocturnal predators which have evolved specific sensory and morphological adaptations to a life in dim light. Here, some of the most fundamental properties of spatial vision in barn owls are reviewed. The eye with its tubular shape is rigidly integrated in the skull so that eye movements are very much restricted. The eyes are oriented frontally, allowing for a large binocular overlap. Accommodation, but not pupil dilation, is coupled between the two eyes. The retina is rod dominated and lacks a visible fovea. Retinal ganglion cells form a marked region of highest density that extends to a horizontally oriented visual streak. Behavioural visual acuity and contrast sensitivity are poor, although the optical quality of the ocular media is excellent. A low f-number allows high image quality at low light levels. Vernier acuity was found to be a hyperacute percept. Owls have global stereopsis with hyperacute stereo acuity thresholds. Neurons of the visual Wulst are sensitive to binocular disparities. Orientation based saliency was demonstrated in a visual-search experiment, and higher cognitive abilities were shown when the owl's were able to use illusory contours for object discrimination.

  1. Restoration of Worn Movable Bridge Props with Use of Bronze Claddings.

    PubMed

    Viňáš, Ján; Vrabeľ, Marek; Greš, Miroslav; Brezina, Jakub; Sabadka, Dušan; Fedorko, Gabriel; Molnár, Vieroslav

    2018-03-21

    This article examined the possibility of using CuSn6P claddings in sliding bearing renovation of movable pontoon bridge props. The bronze layer was welded on cylinders of the high-strength steel S355J0WP EN 10155-93, in an inert atmosphere using an automated welding method (gas tungsten arc welding). Pulsed arc welding was used to minimize the effects of heat on the cladding area, while also accounting for the differences in the physical properties of the joined metals. The sliding bearing was created in two layers. The quality of the cladding layer was evaluated by nondestructive and/or destructive tests. The quality of the surface was assessed by visual inspection (visual testing) in accordance with the EN ISO 17637 standard. The quality of the claddings was evaluated by metallographic analysis, performed using light microscopy. The microhardness values of a few weld areas were determined by Vickers tests, performed according to the EN ISO 9015-2 standard. The analyses confirmed that the welding parameters and filler material used resulted in high-quality weld joints with no internal (subsurface) or metallurgical defects.

  2. Restoration of Worn Movable Bridge Props with Use of Bronze Claddings

    PubMed Central

    Viňáš, Ján; Vrabeľ, Marek; Greš, Miroslav; Brezina, Jakub; Sabadka, Dušan; Fedorko, Gabriel

    2018-01-01

    This article examined the possibility of using CuSn6P claddings in sliding bearing renovation of movable pontoon bridge props. The bronze layer was welded on cylinders of the high-strength steel S355J0WP EN 10155-93, in an inert atmosphere using an automated welding method (gas tungsten arc welding). Pulsed arc welding was used to minimize the effects of heat on the cladding area, while also accounting for the differences in the physical properties of the joined metals. The sliding bearing was created in two layers. The quality of the cladding layer was evaluated by nondestructive and/or destructive tests. The quality of the surface was assessed by visual inspection (visual testing) in accordance with the EN ISO 17637 standard. The quality of the claddings was evaluated by metallographic analysis, performed using light microscopy. The microhardness values of a few weld areas were determined by Vickers tests, performed according to the EN ISO 9015–2 standard. The analyses confirmed that the welding parameters and filler material used resulted in high-quality weld joints with no internal (subsurface) or metallurgical defects. PMID:29561762

  3. PRECOG: a tool for automated extraction and visualization of fitness components in microbial growth phenomics.

    PubMed

    Fernandez-Ricaud, Luciano; Kourtchenko, Olga; Zackrisson, Martin; Warringer, Jonas; Blomberg, Anders

    2016-06-23

    Phenomics is a field in functional genomics that records variation in organismal phenotypes in the genetic, epigenetic or environmental context at a massive scale. For microbes, the key phenotype is the growth in population size because it contains information that is directly linked to fitness. Due to technical innovations and extensive automation our capacity to record complex and dynamic microbial growth data is rapidly outpacing our capacity to dissect and visualize this data and extract the fitness components it contains, hampering progress in all fields of microbiology. To automate visualization, analysis and exploration of complex and highly resolved microbial growth data as well as standardized extraction of the fitness components it contains, we developed the software PRECOG (PREsentation and Characterization Of Growth-data). PRECOG allows the user to quality control, interact with and evaluate microbial growth data with ease, speed and accuracy, also in cases of non-standard growth dynamics. Quality indices filter high- from low-quality growth experiments, reducing false positives. The pre-processing filters in PRECOG are computationally inexpensive and yet functionally comparable to more complex neural network procedures. We provide examples where data calibration, project design and feature extraction methodologies have a clear impact on the estimated growth traits, emphasising the need for proper standardization in data analysis. PRECOG is a tool that streamlines growth data pre-processing, phenotypic trait extraction, visualization, distribution and the creation of vast and informative phenomics databases.

  4. Manual versus Automated Carotid Artery Plaque Component Segmentation in High and Lower Quality 3.0 Tesla MRI Scans

    PubMed Central

    Smits, Loek P.; van Wijk, Diederik F.; Duivenvoorden, Raphael; Xu, Dongxiang; Yuan, Chun; Stroes, Erik S.; Nederveen, Aart J.

    2016-01-01

    Purpose To study the interscan reproducibility of manual versus automated segmentation of carotid artery plaque components, and the agreement between both methods, in high and lower quality MRI scans. Methods 24 patients with 30–70% carotid artery stenosis were planned for 3T carotid MRI, followed by a rescan within 1 month. A multicontrast protocol (T1w,T2w, PDw and TOF sequences) was used. After co-registration and delineation of the lumen and outer wall, segmentation of plaque components (lipid-rich necrotic cores (LRNC) and calcifications) was performed both manually and automated. Scan quality was assessed using a visual quality scale. Results Agreement for the detection of LRNC (Cohen’s kappa (k) is 0.04) and calcification (k = 0.41) between both manual and automated segmentation methods was poor. In the high-quality scans (visual quality score ≥ 3), the agreement between manual and automated segmentation increased to k = 0.55 and k = 0.58 for, respectively, the detection of LRNC and calcification larger than 1 mm2. Both manual and automated analysis showed good interscan reproducibility for the quantification of LRNC (intraclass correlation coefficient (ICC) of 0.94 and 0.80 respectively) and calcified plaque area (ICC of 0.95 and 0.77, respectively). Conclusion Agreement between manual and automated segmentation of LRNC and calcifications was poor, despite a good interscan reproducibility of both methods. The agreement between both methods increased to moderate in high quality scans. These findings indicate that image quality is a critical determinant of the performance of both manual and automated segmentation of carotid artery plaque components. PMID:27930665

  5. [Quality of life in visual impaired children treated for Early Visual Stimulation].

    PubMed

    Messa, Alcione Aparecida; Nakanami, Célia Regina; Lopes, Marcia Caires Bestilleiro

    2012-01-01

    To evaluate the quality of life in visually impaired children followed in the Early Visual Stimulation Ambulatory of Unifesp in two moments, before and after rehabilitational intervention of multiprofessional team. A CVFQ quality of life questionnaire was used. This instrument has a version for less than three years old children and another one for children older than three years (three to seven years) divided in six subscales: General health, General vision health, Competence, Personality, Family impact and Treatment. The correlation between the subscales on two moments was significant. There was a statistically significant difference in general vision health (p=0,029) and other important differences obtained in general health, family impact and quality of life general score. The questionnaire showed to be effective in order to measure the quality of life related to vision on families followed on this ambulatory. The multidisciplinary interventions provided visual function and familiar quality of life improvement. The quality of life related to vision in children followed in Early Visual Stimulation Ambulatory of Unifesp showed a significant improvement on general vision health.

  6. Maui-VIA: A User-Friendly Software for Visual Identification, Alignment, Correction, and Quantification of Gas Chromatography–Mass Spectrometry Data

    PubMed Central

    Kuich, P. Henning J. L.; Hoffmann, Nils; Kempa, Stefan

    2015-01-01

    A current bottleneck in GC–MS metabolomics is the processing of raw machine data into a final datamatrix that contains the quantities of identified metabolites in each sample. While there are many bioinformatics tools available to aid the initial steps of the process, their use requires both significant technical expertise and a subsequent manual validation of identifications and alignments if high data quality is desired. The manual validation is tedious and time consuming, becoming prohibitively so as sample numbers increase. We have, therefore, developed Maui-VIA, a solution based on a visual interface that allows experts and non-experts to simultaneously and quickly process, inspect, and correct large numbers of GC–MS samples. It allows for the visual inspection of identifications and alignments, facilitating a unique and, due to its visualization and keyboard shortcuts, very fast interaction with the data. Therefore, Maui-Via fills an important niche by (1) providing functionality that optimizes the component of data processing that is currently most labor intensive to save time and (2) lowering the threshold of expertise required to process GC–MS data. Maui-VIA projects are initiated with baseline-corrected raw data, peaklists, and a database of metabolite spectra and retention indices used for identification. It provides functionality for retention index calculation, a targeted library search, the visual annotation, alignment, correction interface, and metabolite quantification, as well as the export of the final datamatrix. The high quality of data produced by Maui-VIA is illustrated by its comparison to data attained manually by an expert using vendor software on a previously published dataset concerning the response of Chlamydomonas reinhardtii to salt stress. In conclusion, Maui-VIA provides the opportunity for fast, confident, and high-quality data processing validation of large numbers of GC–MS samples by non-experts. PMID:25654076

  7. The Impact of Visual Disability on the Quality of Life of Older Persons in Rural Northeast Thailand

    ERIC Educational Resources Information Center

    La Grow, Steven; Sudnongbua, Supaporn; Boddy, Julie

    2011-01-01

    A high rate of self-reported visual disability was found among a sample of persons aged 60 and older in the course of a study that assessed the impact of feelings of abandonment among older persons in a remote rural area in northeast Thailand (Sudnongbua, La Grow, & Boddy, 2010). This study assessed the impact of self-reported visual…

  8. An "artificial retina" processor for track reconstruction at the full LHC crossing rate

    NASA Astrophysics Data System (ADS)

    Abba, A.; Bedeschi, F.; Caponio, F.; Cenci, R.; Citterio, M.; Cusimano, A.; Fu, J.; Geraci, A.; Grizzuti, M.; Lusardi, N.; Marino, P.; Morello, M. J.; Neri, N.; Ninci, D.; Petruzzo, M.; Piucci, A.; Punzi, G.; Ristori, L.; Spinella, F.; Stracka, S.; Tonelli, D.; Walsh, J.

    2016-07-01

    We present the latest results of an R&D study for a specialized processor capable of reconstructing, in a silicon pixel detector, high-quality tracks from high-energy collision events at 40 MHz. The processor applies a highly parallel pattern-recognition algorithm inspired to quick detection of edges in mammals visual cortex. After a detailed study of a real-detector application, demonstrating that online reconstruction of offline-quality tracks is feasible at 40 MHz with sub-microsecond latency, we are implementing a prototype using common high-bandwidth FPGA devices.

  9. An "artificial retina" processor for track reconstruction at the full LHC crossing rate

    DOE PAGES

    Abba, A.; F. Bedeschi; Caponio, F.; ...

    2015-10-23

    Here, we present the latest results of an R&D; study for a specialized processor capable of reconstructing, in a silicon pixel detector, high-quality tracks from high-energy collision events at 40 MHz. The processor applies a highly parallel pattern-recognition algorithm inspired to quick detection of edges in mammals visual cortex. After a detailed study of a real-detector application, demonstrating that online reconstruction of offline-quality tracks is feasible at 40 MHz with sub-microsecond latency, we are implementing a prototype using common high-bandwidth FPGA devices.

  10. Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

    PubMed

    Pérez-Vives, Cari; Domínguez-Vicent, Alberto; Madrid-Costa, David; Ferrer-Blasco, Teresa; Montés-Micó, Robert

    2013-03-01

    To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree(-1) were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. At a 3-mm pupil we only found statistically significant differences in VA between the two simulated surgeries at low-contrast for moderate- and high-myopic astigmatism (p < 0.05). Statistically significant differences were found in CS at 3-mm pupil between both procedures at the highest spatial frequency for moderate-myopic astigmatism and at all frequencies for high-myopic astigmatism (p < 0.05). At a 5-mm pupil we found statistically significant differences in VA and CS between both simulated surgeries at all contrasts and frequencies evaluated for both groups (p < 0.05). In all cases VA and CS were better with the TICL than with the bioptics technique. MTFs for the bioptics technique were worse than those computed for the TICL. The TICL showed less spread out of the PSF than the bioptics procedure. Simulated TICL and bioptics procedures provided good optical and visual quality, although TICL implantation provided slightly better outcomes than the bioptics procedure, especially when the pupil diameter was increased. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  11. Visual acuity and quality of life in dry eye disease: Proceedings of the OCEAN group meeting.

    PubMed

    Benítez-Del-Castillo, José; Labetoulle, Marc; Baudouin, Christophe; Rolando, Maurizio; Akova, Yonca A; Aragona, Pasquale; Geerling, Gerd; Merayo-Lloves, Jesús; Messmer, Elisabeth M; Boboridis, Kostas

    2017-04-01

    Dry eye disease (DED) results in tear film instability and hyperosmolarity, inflammation of the ocular surface and, ultimately, visual disturbance that can significantly impact a patient's quality of life. The effects on visual acuity result in difficulties with driving, reading and computer use and negatively impact psychological health. These effects also extend to the workplace, with a loss of productivity and quality of work causing substantial economic losses. The effects of DED and the impact on vision experienced by patients may not be given sufficient importance by ophthalmologists. Functional visual acuity (FVA) is a measure of visual acuity after sustained eye opening without blinking for at least 10 s and mimics the sustained visual acuity of daily life. Measuring dynamic FVA allows the detection of impaired visual function in patients with DED who may display normal conventional visual acuity. There are currently several tests and methods that can be used to measure dynamic visual function: the SSC-350 FVA measurement system, assessment of best-corrected visual acuity decay using the interblink visual acuity decay test, serial measurements of ocular and corneal higher order aberrations, and measurement of dynamic vision quality using the Optical Quality Analysis System. Although the equipment for these methods may be too large or unaffordable for use in clinical practice, FVA testing is an important assessment for DED. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Dynamic simulation of the effect of soft toric contact lenses movement on retinal image quality.

    PubMed

    Niu, Yafei; Sarver, Edwin J; Stevenson, Scott B; Marsack, Jason D; Parker, Katrina E; Applegate, Raymond A

    2008-04-01

    To report the development of a tool designed to dynamically simulate the effect of soft toric contact lens movement on retinal image quality, initial findings on three eyes, and the next steps to be taken to improve the utility of the tool. Three eyes of two subjects wearing soft toric contact lenses were cyclopleged with 1% cyclopentolate and 2.5% phenylephrine. Four hundred wavefront aberration measurements over a 5-mm pupil were recorded during soft contact lens wear at 30 Hz using a complete ophthalmic analysis system aberrometer. Each wavefront error measurement was input into Visual Optics Laboratory (version 7.15, Sarver and Associates, Inc.) to generate a retinal simulation of a high contrast log MAR visual acuity chart. The individual simulations were combined into a single dynamic movie using a custom MatLab PsychToolbox program. Visual acuity was measured for each eye reading the movie with best cycloplegic spectacle correction through a 3-mm artificial pupil to minimize the influence of the eyes' uncorrected aberrations. Comparison of the simulated acuity was made to values recorded while the subject read unaberrated charts with contact lenses through a 5-mm artificial pupil. For one study eye, average acuity was the same as the natural contact lens viewing condition. For the other two study eyes visual acuity of the best simulation was more than one line worse than natural viewing conditions. Dynamic simulation of retinal image quality, although not yet perfect, is a promising technique for visually illustrating the optical effects on image quality because of the movements of alignment-sensitive corrections.

  13. Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system.

    PubMed

    Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H

    2015-06-01

    To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.

  14. Data Driven Quality Improvement of Health Professions Education: Design and Development of CLUE - An Interactive Curriculum Data Visualization Tool.

    PubMed

    Canning, Claire Ann; Loe, Alan; Cockett, Kathryn Jane; Gagnon, Paul; Zary, Nabil

    2017-01-01

    Curriculum Mapping and dynamic visualization is quickly becoming an integral aspect of quality improvement in support of innovations which drive curriculum quality assurance processes in medical education. CLUE (Curriculum Explorer) a highly interactive, engaging and independent platform was developed to support curriculum transparency, enhance student engagement, and enable granular search and display. Reflecting a design based approach to meet the needs of the school's varied stakeholders, CLUE employs an iterative and reflective approach to drive the evolution of its platform, as it seeks to accommodate the ever-changing needs of our stakeholders in the fast pace world of medicine and medical education today. CLUE exists independent of institutional systems and in this way, is uniquely positioned to deliver a data driven quality improvement resource, easily adaptable for use by any member of our health care professions.

  15. Visualizing Topic Flow in Students' Essays

    ERIC Educational Resources Information Center

    O'Rourke, Stephen T.; Calvo, Rafael A.; McNamara, Danielle S.

    2011-01-01

    Visualizing how the parts of a document relate to each other and producing automatically generated quality measures that people can understand are means that writers can use to improve the quality of their compositions. This paper presents a novel document visualization technique and a measure of quality based on the average semantic distance…

  16. Association between Visual Impairment and Low Vision and Sleep Duration and Quality among Older Adults in South Africa.

    PubMed

    Peltzer, Karl; Phaswana-Mafuya, Nancy

    2017-07-19

    This study aims to estimate the association between visual impairment and low vision and sleep duration and poor sleep quality in a national sample of older adults in South Africa. A national population-based cross-sectional Study of Global Ageing and Adults Health (SAGE) wave 1 was conducted in 2008 with a sample of 3840 individuals aged 50 years or older in South Africa. The interviewer-administered questionnaire assessed socio-demographic characteristics, health variables, sleep duration, quality, visual impairment, and vision. Results indicate that 10.0% of the sample reported short sleep duration (≤5 h), 46.6% long sleep (≥9 h), 9.3% poor sleep quality, 8.4% self-reported and visual impairment (near and/or far vision); and 43.2% measured low vision (near and/or far vision) (0.01-0.25 decimal) and 7.5% low vision (0.01-0.125 decimal). In fully adjusted logistic regression models, self-reported visual impairment was associated with short sleep duration and poor sleep quality, separately and together. Low vision was only associated with long sleep duration and poor sleep quality in unadjusted models. Self-reported visual impairment was related to both short sleep duration and poor sleep quality. Population data on sleep patterns may want to include visual impairment measures.

  17. Eccentric correction for off-axis vision in central visual field loss.

    PubMed

    Gustafsson, Jörgen; Unsbo, Peter

    2003-07-01

    Subjects with absolute central visual field loss use eccentric fixation and magnifying devices to utilize their residual vision. This preliminary study investigated the importance of an accurate eccentric correction of off-axis refractive errors to optimize the residual visual function for these subjects. Photorefraction using the PowerRefractor instrument was used to evaluate the ametropia in eccentric fixation angles. Methods were adapted for measuring visual acuity outside the macula using filtered optotypes from high-pass resolution perimetry. Optical corrections were implemented, and the visual function of subjects with central visual field loss was measured with and without eccentric correction. Of the seven cases reported, five experienced an improvement in visual function in their preferred retinal locus with eccentric refraction. The main result was that optical correction for better image quality on the peripheral retina is important for the vision of subjects with central visual field loss, objectively as well as subjectively.

  18. High performance visual display for HENP detectors

    NASA Astrophysics Data System (ADS)

    McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel

    2001-08-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations.

  19. Toward a perceptual video-quality metric

    NASA Astrophysics Data System (ADS)

    Watson, Andrew B.

    1998-07-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating the visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics, and the economic need to reduce bit-rate to the lowest level that yields acceptable quality. In previous work, we have developed visual quality metrics for evaluating, controlling,a nd optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. Here I describe a new video quality metric that is an extension of these still image metrics into the time domain. Like the still image metrics, it is based on the Discrete Cosine Transform. An effort has been made to minimize the amount of memory and computation required by the metric, in order that might be applied in the widest range of applications. To calibrate the basic sensitivity of this metric to spatial and temporal signals we have made measurements of visual thresholds for temporally varying samples of DCT quantization noise.

  20. Visualizing desirable patient healthcare experiences.

    PubMed

    Liu, Sandra S; Kim, Hyung T; Chen, Jie; An, Lingling

    2010-01-01

    High healthcare cost has drawn much attention and healthcare service providers (HSPs) are expected to deliver high-quality and consistent care. Therefore, an intimate understanding of the most desirable experience from a patient's and/or family's perspective as well as effective mapping and communication of such findings should facilitate HSPs' efforts in attaining sustainable competitive advantage in an increasingly discerning environment. This study describes (a) the critical quality attributes (CQAs) of the experience desired by patients and (b) the application of two visualization tools that are relatively new to the healthcare sector, namely the "spider-web diagram" and "promotion and detraction matrix." The visualization tools are tested with primary data collected from telephone surveys of 1,800 patients who had received care during calendar year 2005 at 6 of 61 hospitals within St. Louis, Missouri-based, Ascension Health. Five CQAs were found by factor analysis. The spider-web diagram illustrates that communication and empowerment and compassionate and respectful care are the most important CQAs, and accordingly, the promotion and detraction matrix shows those attributes that have the greatest effect for creating promoters, preventing detractors, and improving consumer's likelihood to recommend the healthcare provider.

  1. High-quality slab-based intermixing method for fusion rendering of multiple medical objects.

    PubMed

    Kim, Dong-Joon; Kim, Bohyoung; Lee, Jeongjin; Shin, Juneseuk; Kim, Kyoung Won; Shin, Yeong-Gil

    2016-01-01

    The visualization of multiple 3D objects has been increasingly required for recent applications in medical fields. Due to the heterogeneity in data representation or data configuration, it is difficult to efficiently render multiple medical objects in high quality. In this paper, we present a novel intermixing scheme for fusion rendering of multiple medical objects while preserving the real-time performance. First, we present an in-slab visibility interpolation method for the representation of subdivided slabs. Second, we introduce virtual zSlab, which extends an infinitely thin boundary (such as polygonal objects) into a slab with a finite thickness. Finally, based on virtual zSlab and in-slab visibility interpolation, we propose a slab-based visibility intermixing method with the newly proposed rendering pipeline. Experimental results demonstrate that the proposed method delivers more effective multiple-object renderings in terms of rendering quality, compared to conventional approaches. And proposed intermixing scheme provides high-quality intermixing results for the visualization of intersecting and overlapping surfaces by resolving aliasing and z-fighting problems. Moreover, two case studies are presented that apply the proposed method to the real clinical applications. These case studies manifest that the proposed method has the outstanding advantages of the rendering independency and reusability. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Comparative analysis of visual outcomes with 4 intraocular lenses: Monofocal, multifocal, and extended range of vision.

    PubMed

    Pedrotti, Emilio; Carones, Francesco; Aiello, Francesco; Mastropasqua, Rodolfo; Bruni, Enrico; Bonacci, Erika; Talli, Pietro; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2018-02-01

    To compare the visual acuity, refractive outcomes, and quality of vision in patients with bilateral implantation of 4 intraocular lenses (IOLs). Department of Neurosciences, Biomedicine and Movement Sciences, Eye Clinic, University of Verona, Verona, and Carones Ophthalmology Center, Milano, Italy. Prospective case series. The study included patients who had bilateral cataract surgery with the implantation of 1 of 4 IOLs as follows: Tecnis 1-piece monofocal (monofocal IOL), Tecnis Symfony extended range of vision (extended-range-of-vision IOL), Restor +2.5 diopter (D) (+2.5 D multifocal IOL), and Restor +3.0 D (+3.0 D multifocal IOL). Visual acuity, refractive outcome, defocus curve, objective optical quality, contrast sensitivity, spectacle independence, and glare perception were evaluated 6 months after surgery. The study comprised 185 patients. The extended-range-of-vision IOL (55 patients) showed better distance visual outcomes than the monofocal IOL (30 patients) and high-addition apodized diffractive-refractive multifocal IOLs (P ≤ .002). The +3.0 D multifocal IOL (50 patients) showed the best near visual outcomes (P < .001). The +2.5 D multifocal IOL (50 patients) and extended-range-of-vision IOL provided significantly better intermediate visual outcomes than the other 2 IOLs, with significantly better vision for a defocus level of -1.5 D (P < .001). Better spectacle independence was shown for the +2.5 D multifocal IOL and extended-range-of-vision IOL (P < .001). The extended-range-of-vision IOL and +2.5 D multifocal IOL provided significantly better intermediate visual restoration after cataract surgery than the monofocal IOL and +3.0 D multifocal IOL, with significantly better quality of vision with the extended-range-of-vision IOL. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Scalable large format 3D displays

    NASA Astrophysics Data System (ADS)

    Chang, Nelson L.; Damera-Venkata, Niranjan

    2010-02-01

    We present a general framework for the modeling and optimization of scalable large format 3-D displays using multiple projectors. Based on this framework, we derive algorithms that can robustly optimize the visual quality of an arbitrary combination of projectors (e.g. tiled, superimposed, combinations of the two) without manual adjustment. The framework creates for the first time a new unified paradigm that is agnostic to a particular configuration of projectors yet robustly optimizes for the brightness, contrast, and resolution of that configuration. In addition, we demonstrate that our algorithms support high resolution stereoscopic video at real-time interactive frame rates achieved on commodity graphics hardware. Through complementary polarization, the framework creates high quality multi-projector 3-D displays at low hardware and operational cost for a variety of applications including digital cinema, visualization, and command-and-control walls.

  4. CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons.

    PubMed

    Kalia, Vivek; Fritz, Benjamin; Johnson, Rory; Gilson, Wesley D; Raithel, Esther; Fritz, Jan

    2017-09-01

    To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. • High-resolution 3D TSE MRI improves visualization of ankle structures. • Limitations of current 3D TSE MRI include long scan times. • 3D CAIPIRINHA SPACE allows now a fourfold-accelerated data acquisition. • 3D CAIPIRINHA SPACE enables high-spatial-resolution ankle MRI within 10 min. • 10-min 3D CAIPIRINHA SPACE produces equal-or-better quality than 20-min 2D TSE.

  5. Image gathering and restoration - Information and visual quality

    NASA Technical Reports Server (NTRS)

    Mccormick, Judith A.; Alter-Gartenberg, Rachel; Huck, Friedrich O.

    1989-01-01

    A method is investigated for optimizing the end-to-end performance of image gathering and restoration for visual quality. To achieve this objective, one must inevitably confront the problems that the visual quality of restored images depends on perceptual rather than mathematical considerations and that these considerations vary with the target, the application, and the observer. The method adopted in this paper is to optimize image gathering informationally and to restore images interactively to obtain the visually preferred trade-off among fidelity resolution, sharpness, and clarity. The results demonstrate that this method leads to significant improvements in the visual quality obtained by the traditional digital processing methods. These traditional methods allow a significant loss of visual quality to occur because they treat the design of the image-gathering system and the formulation of the image-restoration algorithm as two separate tasks and fail to account for the transformations between the continuous and the discrete representations in image gathering and reconstruction.

  6. Quality Services for Blind and Visually Handicapped Learners. Statements of Position.

    ERIC Educational Resources Information Center

    Scholl, Geraldine T., Ed.

    Seventeen position papers address essential elements in quality programing for visually handicapped learners. The papers represent the philosophy of the Council for Exceptional Children's Division for the Visually Handicapped. Following two foundation position papers, "Services for the Blind and Visually Impaired" (K. Huebner) and "Visually…

  7. Building conservation base on assessment of facade quality on Basuki Rachmat Street, Malang

    NASA Astrophysics Data System (ADS)

    Kurniawan, E. B.; Putri, R. Y. A.; Wardhani, D. K.

    2017-06-01

    Visual quality covers aspects of imageability which is associated with visual system and the element of distinction. Within a visual system of specific area, the physical quality may lead to a strong image. Here, the physical quality is one of important that make urban aesthetic. Build a discussion toward visual system of urban area, this paper aim is to identify the influencing factors in defining the façade’s visual quality of heritage buildings at Jend. Basuki Rahmat Street, Malang City, East Java-Indonesia. This Street is a main road of Malang city center that was built by Dutch colonial government. It was designed by IR. Thomas Kartsten. It was known as one of Malang area that have good visual quality. In order to idenfity the influencing factors, this paper conducts Multiple linear regression as a tools of analysis. The examined potential factors are resulted from of architecture and urban design expert’s assessment to each building’s segment at Jend. Basuki Rahmat. Finally, this paper reveals that the influencing factors are color, rhythm, and proportion. This is demonstrated by the results model: Visual quality (Y) = 0.304 + 0.21 Colors(X5) + 0.221 rhythm (X6) + 0.304 proportion (X7). Furthermore, the recommendation of the building facade will be made based on this model and study of historical and typology building in Basuki Rachmat Street.

  8. A new approach to subjectively assess quality of plenoptic content

    NASA Astrophysics Data System (ADS)

    Viola, Irene; Řeřábek, Martin; Ebrahimi, Touradj

    2016-09-01

    Plenoptic content is becoming increasingly popular thanks to the availability of acquisition and display devices. Thanks to image-based rendering techniques, a plenoptic content can be rendered in real time in an interactive manner allowing virtual navigation through the captured scenes. This way of content consumption enables new experiences, and therefore introduces several challenges in terms of plenoptic data processing, transmission and consequently visual quality evaluation. In this paper, we propose a new methodology to subjectively assess the visual quality of plenoptic content. We also introduce a prototype software to perform subjective quality assessment according to the proposed methodology. The proposed methodology is further applied to assess the visual quality of a light field compression algorithm. Results show that this methodology can be successfully used to assess the visual quality of plenoptic content.

  9. Change in Quality of Life after Rehabilitation: Prognostic Factors for Visually Impaired Adults

    ERIC Educational Resources Information Center

    Langelaan, Maaike; de Boer, Michiel R.; van Nispen, Ruth M. A.; Wouters, Bill; Moll, Annette C.; van Rens, Ger H. M. B.

    2009-01-01

    The overall aim of rehabilitation for visually impaired adults is to improve the quality of life and (societal) participation. The objectives of this study were to obtain the short-term and long-term outcome of a comprehensive rehabilitation programme on quality of life for visually impaired adults, and prognostic baseline factors responsible for…

  10. Integration of visual quality considerations in development of Israeli vegetation management policy.

    PubMed

    Misgav, A; Amir, S

    2001-06-01

    This article deals with the visual quality of Mediterranean vegetation groups in northern Israel, the public's preference of these groups as a visual resource, and the policy options for their management. The study is based on a sample of 44 Mediterranean vegetation groups and three population groups of local residents, who were interviewed using a questionnaire and photographs of the vegetation groups. The results of the research showed that plant classification methods based on flora composition, habitat, and external appearance were found to be suitable for visual plant classification and for the evaluation of visual preference of vegetation groups by the interviewed public. The vegetation groups of planted pine forests and olive groves, characterizing a cultured vegetation landscape, were preferred over typical Mediterranean landscapes such as scrub and grassed scrub. The researchers noted a marked difference between the two products of vegetation management policy, one that proposes the conservation and restoration of the variety of native Mediterranean vegetation landscape, and a second that advanced the development of the cultured landscape of planted olive groves and pines forests, which were highly preferred by the public. The authors suggested the development of an integrated vegetation management policy that would combine both needs and thus reduce the gap between the policy proposed by planners and the local population's visual preference.

  11. [An epidemiological study of visual disability and visual rehabilitation in Beijing].

    PubMed

    Zou, Yan-hong; Ding, Ji-yuan; Peng, Hong; Shi, Ji-liang; Qu, Cheng-yi; Liu, Xi-pu

    2009-12-01

    To investigate the status of visual disability and the demands for visual rehabilitation services in Beijing. Five hundred and fifty-five persons with visual disability in Beijing from the Second National Survey on Disability of China were involved in this study. Their visual disability and demands for rehabilitation were evaluated. About three fourth of the visual disabled persons were over 60 years of age. Cataract, retinal and choroidal diseases, and glaucoma were the three leading causes of the visual impairment. Medical service was the number one (82.0%) demand for the persons with visual disability, although 89.4% of them had previously received some kinds of medial services. People who had received visual aid devices or rehabilitation training were 26.7% and 5.8%, respectively, while more people showed their demand for these service (36.6% and 11.9%, respectively). The demand for visual rehabilitation varied in different groups of age and severity of disability. Accessibility of high quality medical services for preventable blindness diseases should be further promoted. Public health education on visual rehabilitation is also needed.

  12. fluff: exploratory analysis and visualization of high-throughput sequencing data

    PubMed Central

    Georgiou, Georgios

    2016-01-01

    Summary. In this article we describe fluff, a software package that allows for simple exploration, clustering and visualization of high-throughput sequencing data mapped to a reference genome. The package contains three command-line tools to generate publication-quality figures in an uncomplicated manner using sensible defaults. Genome-wide data can be aggregated, clustered and visualized in a heatmap, according to different clustering methods. This includes a predefined setting to identify dynamic clusters between different conditions or developmental stages. Alternatively, clustered data can be visualized in a bandplot. Finally, fluff includes a tool to generate genomic profiles. As command-line tools, the fluff programs can easily be integrated into standard analysis pipelines. The installation is straightforward and documentation is available at http://fluff.readthedocs.org. Availability. fluff is implemented in Python and runs on Linux. The source code is freely available for download at https://github.com/simonvh/fluff. PMID:27547532

  13. imDEV: a graphical user interface to R multivariate analysis tools in Microsoft Excel.

    PubMed

    Grapov, Dmitry; Newman, John W

    2012-09-01

    Interactive modules for Data Exploration and Visualization (imDEV) is a Microsoft Excel spreadsheet embedded application providing an integrated environment for the analysis of omics data through a user-friendly interface. Individual modules enables interactive and dynamic analyses of large data by interfacing R's multivariate statistics and highly customizable visualizations with the spreadsheet environment, aiding robust inferences and generating information-rich data visualizations. This tool provides access to multiple comparisons with false discovery correction, hierarchical clustering, principal and independent component analyses, partial least squares regression and discriminant analysis, through an intuitive interface for creating high-quality two- and a three-dimensional visualizations including scatter plot matrices, distribution plots, dendrograms, heat maps, biplots, trellis biplots and correlation networks. Freely available for download at http://sourceforge.net/projects/imdev/. Implemented in R and VBA and supported by Microsoft Excel (2003, 2007 and 2010).

  14. Visual Communications And Image Processing

    NASA Astrophysics Data System (ADS)

    Hsing, T. Russell; Tzou, Kou-Hu

    1989-07-01

    This special issue on Visual Communications and Image Processing contains 14 papers that cover a wide spectrum in this fast growing area. For the past few decades, researchers and scientists have devoted their efforts to these fields. Through this long-lasting devotion, we witness today the growing popularity of low-bit-rate video as a convenient tool for visual communication. We also see the integration of high-quality video into broadband digital networks. Today, with more sophisticated processing, clearer and sharper pictures are being restored from blurring and noise. Also, thanks to the advances in digital image processing, even a PC-based system can be built to recognize highly complicated Chinese characters at the speed of 300 characters per minute. This special issue can be viewed as a milestone of visual communications and image processing on its journey to eternity. It presents some overviews on advanced topics as well as some new development in specific subjects.

  15. Image gathering and coding for digital restoration: Information efficiency and visual quality

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; John, Sarah; Mccormick, Judith A.; Narayanswamy, Ramkumar

    1989-01-01

    Image gathering and coding are commonly treated as tasks separate from each other and from the digital processing used to restore and enhance the images. The goal is to develop a method that allows us to assess quantitatively the combined performance of image gathering and coding for the digital restoration of images with high visual quality. Digital restoration is often interactive because visual quality depends on perceptual rather than mathematical considerations, and these considerations vary with the target, the application, and the observer. The approach is based on the theoretical treatment of image gathering as a communication channel (J. Opt. Soc. Am. A2, 1644(1985);5,285(1988). Initial results suggest that the practical upper limit of the information contained in the acquired image data range typically from approximately 2 to 4 binary information units (bifs) per sample, depending on the design of the image-gathering system. The associated information efficiency of the transmitted data (i.e., the ratio of information over data) ranges typically from approximately 0.3 to 0.5 bif per bit without coding to approximately 0.5 to 0.9 bif per bit with lossless predictive compression and Huffman coding. The visual quality that can be attained with interactive image restoration improves perceptibly as the available information increases to approximately 3 bifs per sample. However, the perceptual improvements that can be attained with further increases in information are very subtle and depend on the target and the desired enhancement.

  16. The role of extra-foveal processing in 3D imaging

    NASA Astrophysics Data System (ADS)

    Eckstein, Miguel P.; Lago, Miguel A.; Abbey, Craig K.

    2017-03-01

    The field of medical image quality has relied on the assumption that metrics of image quality for simple visual detection tasks are a reliable proxy for the more clinically realistic visual search tasks. Rank order of signal detectability across conditions often generalizes from detection to search tasks. Here, we argue that search in 3D images represents a paradigm shift in medical imaging: radiologists typically cannot exhaustively scrutinize all regions of interest with the high acuity fovea requiring detection of signals with extra-foveal areas (visual periphery) of the human retina. We hypothesize that extra-foveal processing can alter the detectability of certain types of signals in medical images with important implications for search in 3D medical images. We compare visual search of two different types of signals in 2D vs. 3D images. We show that a small microcalcification-like signal is more highly detectable than a larger mass-like signal in 2D search, but its detectability largely decreases (relative to the larger signal) in the 3D search task. Utilizing measurements of observer detectability as a function retinal eccentricity and observer eye fixations we can predict the pattern of results in the 2D and 3D search studies. Our findings: 1) suggest that observer performance findings with 2D search might not always generalize to 3D search; 2) motivate the development of a new family of model observers that take into account the inhomogeneous visual processing across the retina (foveated model observers).

  17. Efficacy of a perceptual and visual-motor skill intervention program for students with dyslexia.

    PubMed

    Fusco, Natália; Germano, Giseli Donadon; Capellini, Simone Aparecida

    2015-01-01

    To verify the efficacy of a perceptual and visual-motor skill intervention program for students with dyslexia. The participants were 20 students from third to fifth grade of a public elementary school in Marília, São Paulo, aged from 8 years to 11 years and 11 months, distributed into the following groups: Group I (GI; 10 students with developmental dyslexia) and Group II (GII; 10 students with good academic performance). A perceptual and visual-motor intervention program was applied, which comprised exercises for visual-motor coordination, visual discrimination, visual memory, visual-spatial relationship, shape constancy, sequential memory, visual figure-ground coordination, and visual closure. In pre- and post-testing situations, both groups were submitted to the Test of Visual-Perceptual Skills (TVPS-3), and the quality of handwriting was analyzed using the Dysgraphia Scale. The analyzed statistical results showed that both groups of students had dysgraphia in pretesting situation. In visual perceptual skills, GI presented a lower performance compared to GII, as well as in the quality of writing. After undergoing the intervention program, GI increased the average of correct answers in TVPS-3 and improved the quality of handwriting. The developed intervention program proved appropriate for being applied to students with dyslexia, and showed positive effects because it provided improved visual perception skills and quality of writing for students with developmental dyslexia.

  18. Using Films in the Multimedia English Class

    ERIC Educational Resources Information Center

    Wang, Youming

    2009-01-01

    With the great, constant renovation and development of various knowledge and economy, talents of compound, high quality and high skills are in urgent need in society; a new educational reform runs through the whole foreign teaching courses, including audio-visual course, speaking, reading, writing and translating courses. With the aid of…

  19. Automated surface quality inspection with ARGOS: a case study

    NASA Astrophysics Data System (ADS)

    Kiefhaber, Daniel; Etzold, Fabian; Warken, Arno F.; Asfour, Jean-Michel

    2017-06-01

    The commercial availability of automated inspection systems for optical surfaces specified according to ISO 10110-7 promises unsupervised and automated quality control with reproducible results. In this study, the classification results of the ARGOS inspection system are compared to the decisions by well-trained inspectors based on manual-visual inspection. Both are found to agree in 93.6% of the studied cases. Exemplary cases with differing results are studied, and shown to be partly caused by shortcomings of the ISO 10110-7 standard, which was written for the industry standard manual-visual inspection. Applying it to high resolution images of the whole surface of objective machine vision systems brings with it a few challenges which are discussed.

  20. ShortRead: a bioconductor package for input, quality assessment and exploration of high-throughput sequence data

    PubMed Central

    Morgan, Martin; Anders, Simon; Lawrence, Michael; Aboyoun, Patrick; Pagès, Hervé; Gentleman, Robert

    2009-01-01

    Summary: ShortRead is a package for input, quality assessment, manipulation and output of high-throughput sequencing data. ShortRead is provided in the R and Bioconductor environments, allowing ready access to additional facilities for advanced statistical analysis, data transformation, visualization and integration with diverse genomic resources. Availability and Implementation: This package is implemented in R and available at the Bioconductor web site; the package contains a ‘vignette’ outlining typical work flows. Contact: mtmorgan@fhcrc.org PMID:19654119

  1. LOD map--A visual interface for navigating multiresolution volume visualization.

    PubMed

    Wang, Chaoli; Shen, Han-Wei

    2006-01-01

    In multiresolution volume visualization, a visual representation of level-of-detail (LOD) quality is important for us to examine, compare, and validate different LOD selection algorithms. While traditional methods rely on ultimate images for quality measurement, we introduce the LOD map--an alternative representation of LOD quality and a visual interface for navigating multiresolution data exploration. Our measure for LOD quality is based on the formulation of entropy from information theory. The measure takes into account the distortion and contribution of multiresolution data blocks. A LOD map is generated through the mapping of key LOD ingredients to a treemap representation. The ordered treemap layout is used for relative stable update of the LOD map when the view or LOD changes. This visual interface not only indicates the quality of LODs in an intuitive way, but also provides immediate suggestions for possible LOD improvement through visually-striking features. It also allows us to compare different views and perform rendering budget control. A set of interactive techniques is proposed to make the LOD adjustment a simple and easy task. We demonstrate the effectiveness and efficiency of our approach on large scientific and medical data sets.

  2. Astronomy Data Visualization with Blender

    NASA Astrophysics Data System (ADS)

    Kent, Brian R.

    2015-08-01

    We present innovative methods and techniques for using Blender, a 3D software package, in the visualization of astronomical data. N-body simulations, data cubes, galaxy and stellar catalogs, and planetary surface maps can be rendered in high quality videos for exploratory data analysis. Blender's API is Python based, making it advantageous for use in astronomy with flexible libraries like astroPy. Examples will be exhibited that showcase the features of the software in astronomical visualization paradigms. 2D and 3D voxel texture applications, animations, camera movement, and composite renders are introduced to the astronomer's toolkit and how they mesh with different forms of data.

  3. Improving vision by pupil masking

    PubMed Central

    Bonaque-González, Sergio; Ríos-Rodríguez, Susana; López-Gil, Norberto

    2016-01-01

    We propose an alternative solution to improve visual quality by spatially modulating the amplitude of light passing into the eye (related to the eye's transmittance), in contrast to traditional correction of the wavefront phase (related to the local refractive power). Numerical simulations show that masking the aberrated areas at the pupil plane should enhance visual function, especially in highly aberrated eyes. This correction could be implemented in practice using customized contact or intraocular lenses. PMID:27446688

  4. The challenges in improving outcome of cataract surgery in low and middle income countries

    PubMed Central

    Lindfield, Robert; Vishwanath, Kalluru; Ngounou, Faustin; Khanna, Rohit C

    2012-01-01

    Cataract is the leading cause of blindness globally and surgery is the only known measure to deal with it effectively. Providing high quality cataract surgical services is critical if patients with cataract are to have their sight restored. A key focus of surgery is the outcome of the procedure. In cataract surgery this is measured predominantly, using visual acuity. Population- and hospital-based studies have revealed that the visual outcome of cataract surgery in many low and middle income settings is frequently sub-optimal, often failing to reach the recommended standards set by the World Health Organization (WHO). Another way of measuring outcome of cataract surgery is to ask patients for their views on whether surgery has changed the functioning of their eyes and their quality of life. There are different tools available to capture patient views and now, these patient-reported outcomes are becoming more widely used. This paper discusses the visual outcome of cataract surgery and frames the outcome of surgery within the context of the surgical service, suggesting that the process and outcome of care cannot be separated. It also discusses the components of patient-reported outcome tools and describes some available tools in more detail. Finally, it describes a hierarchy of challenges that need to be addressed before a high quality cataract surgical service can be achieved. PMID:22944761

  5. The Nencki Affective Picture System (NAPS): introduction to a novel, standardized, wide-range, high-quality, realistic picture database.

    PubMed

    Marchewka, Artur; Zurawski, Łukasz; Jednoróg, Katarzyna; Grabowska, Anna

    2014-06-01

    Selecting appropriate stimuli to induce emotional states is essential in affective research. Only a few standardized affective stimulus databases have been created for auditory, language, and visual materials. Numerous studies have extensively employed these databases using both behavioral and neuroimaging methods. However, some limitations of the existing databases have recently been reported, including limited numbers of stimuli in specific categories or poor picture quality of the visual stimuli. In the present article, we introduce the Nencki Affective Picture System (NAPS), which consists of 1,356 realistic, high-quality photographs that are divided into five categories (people, faces, animals, objects, and landscapes). Affective ratings were collected from 204 mostly European participants. The pictures were rated according to the valence, arousal, and approach-avoidance dimensions using computerized bipolar semantic slider scales. Normative ratings for the categories are presented for each dimension. Validation of the ratings was obtained by comparing them to ratings generated using the Self-Assessment Manikin and the International Affective Picture System. In addition, the physical properties of the photographs are reported, including luminance, contrast, and entropy. The new database, with accompanying ratings and image parameters, allows researchers to select a variety of visual stimulus materials specific to their experimental questions of interest. The NAPS system is freely accessible to the scientific community for noncommercial use by request at http://naps.nencki.gov.pl .

  6. Aesthetics by Numbers: Links between Perceived Texture Qualities and Computed Visual Texture Properties.

    PubMed

    Jacobs, Richard H A H; Haak, Koen V; Thumfart, Stefan; Renken, Remco; Henson, Brian; Cornelissen, Frans W

    2016-01-01

    Our world is filled with texture. For the human visual system, this is an important source of information for assessing environmental and material properties. Indeed-and presumably for this reason-the human visual system has regions dedicated to processing textures. Despite their abundance and apparent relevance, only recently the relationships between texture features and high-level judgments have captured the interest of mainstream science, despite long-standing indications for such relationships. In this study, we explore such relationships, as these might be used to predict perceived texture qualities. This is relevant, not only from a psychological/neuroscience perspective, but also for more applied fields such as design, architecture, and the visual arts. In two separate experiments, observers judged various qualities of visual textures such as beauty, roughness, naturalness, elegance, and complexity. Based on factor analysis, we find that in both experiments, ~75% of the variability in the judgments could be explained by a two-dimensional space, with axes that are closely aligned to the beauty and roughness judgments. That a two-dimensional judgment space suffices to capture most of the variability in the perceived texture qualities suggests that observers use a relatively limited set of internal scales on which to base various judgments, including aesthetic ones. Finally, for both of these judgments, we determined the relationship with a large number of texture features computed for each of the texture stimuli. We find that the presence of lower spatial frequencies, oblique orientations, higher intensity variation, higher saturation, and redness correlates with higher beauty ratings. Features that captured image intensity and uniformity correlated with roughness ratings. Therefore, a number of computational texture features are predictive of these judgments. This suggests that perceived texture qualities-including the aesthetic appreciation-are sufficiently universal to be predicted-with reasonable accuracy-based on the computed feature content of the textures.

  7. Helping Educators Find Visualizations and Teaching Materials Just-in-Time

    NASA Astrophysics Data System (ADS)

    McDaris, J.; Manduca, C. A.; MacDonald, R. H.

    2005-12-01

    Major events and natural disasters like hurricanes and tsunamis provide geoscience educators with powerful teachable moments to engage their students with class content. In order to take advantage of these opportunities, educators need quality topical resources related to current earth science events. The web has become an excellent vehicle for disseminating this type of resource. In response to the 2004 Indian Ocean Earthquake and to Hurricane Katrina's devastating impact on the US Gulf Coast, the On the Cutting Edge professional development program developed collections of visualizations for use in teaching. (serc.carleton.edu/NAGTWorkshops/visualization/collections/ tsunami.html,serc.carleton.edu/NAGTWorkshops/visualization/ collections/hurricanes.html). These sites are collections of links to visualizations and other materials that can support the efforts of faculty, teachers, and those engaged in public outreach. They bring together resources created by researchers, government agencies and respected media sources and organize them for easy use by educators. Links are selected to provide a variety of different types of visualizations (e.g photographic images, animations, satellite imagery) and to assist educators in teaching about the geologic event reported in the news, associated Earth science concepts, and related topics of high interest. The cited links are selected from quality sources and are reviewed by SERC staff before being included on the page. Geoscience educators are encouraged to recommend links and supporting materials and to comment on the available resources. In this way the collection becomes more complete and its quality is enhanced.. These sites have received substantial use (Tsunami - 77,000 visitors in the first 3 months, Hurricanes - 2500 visitors in the first week) indicating that in addition to use by educators, they are being used by the general public seeking information about the events. Thus they provide an effective mechanism for guiding the public to quality resources created by geoscience researchers and facilities, in addition to supporting incorporation of geoscience research in education.

  8. An ecological alternative to Snodgrass & Vanderwart: 360 high quality colour images with norms for seven psycholinguistic variables.

    PubMed

    Moreno-Martínez, Francisco Javier; Montoro, Pedro R

    2012-01-01

    This work presents a new set of 360 high quality colour images belonging to 23 semantic subcategories. Two hundred and thirty-six Spanish speakers named the items and also provided data from seven relevant psycholinguistic variables: age of acquisition, familiarity, manipulability, name agreement, typicality and visual complexity. Furthermore, we also present lexical frequency data derived from Internet search hits. Apart from the high number of variables evaluated, knowing that it affects the processing of stimuli, this new set presents important advantages over other similar image corpi: (a) this corpus presents a broad number of subcategories and images; for example, this will permit researchers to select stimuli of appropriate difficulty as required, (e.g., to deal with problems derived from ceiling effects); (b) the fact of using coloured stimuli provides a more realistic, ecologically-valid, representation of real life objects. In sum, this set of stimuli provides a useful tool for research on visual object- and word-processing, both in neurological patients and in healthy controls.

  9. Visual quality assessment of alternative silvicultural practices in upland hardwood management

    Treesearch

    Tim McDonald; Bryce Stokes

    1997-01-01

    Visual impacts of forest operations are of increasing concern to forest managers. Tools are available for evaluating, and potentially avoiding, problems in visual quality resulting from poorly designed harvest unit boundaries. One of these visualization tools is applied in comparing various harvest unit shape alternatives in an upland hardwood stand on steeply sloping...

  10. A Bayesian Nonparametric Approach to Image Super-Resolution.

    PubMed

    Polatkan, Gungor; Zhou, Mingyuan; Carin, Lawrence; Blei, David; Daubechies, Ingrid

    2015-02-01

    Super-resolution methods form high-resolution images from low-resolution images. In this paper, we develop a new Bayesian nonparametric model for super-resolution. Our method uses a beta-Bernoulli process to learn a set of recurring visual patterns, called dictionary elements, from the data. Because it is nonparametric, the number of elements found is also determined from the data. We test the results on both benchmark and natural images, comparing with several other models from the research literature. We perform large-scale human evaluation experiments to assess the visual quality of the results. In a first implementation, we use Gibbs sampling to approximate the posterior. However, this algorithm is not feasible for large-scale data. To circumvent this, we then develop an online variational Bayes (VB) algorithm. This algorithm finds high quality dictionaries in a fraction of the time needed by the Gibbs sampler.

  11. sbv IMPROVER: Modern Approach to Systems Biology.

    PubMed

    Guryanova, Svetlana; Guryanova, Anna

    2017-01-01

    The increasing amount and variety of data in biosciences call for innovative methods of visualization, scientific verification, and pathway analysis. Novel approaches to biological networks and research quality control are important because of their role in development of new products, improvement, and acceleration of existing health policies and research for novel ways of solving scientific challenges. One such approach is sbv IMPROVER. It is a platform that uses crowdsourcing and verification to create biological networks with easy public access. It contains 120 networks built in Biological Expression Language (BEL) to interpret data from PubMed articles with high-quality verification available for free on the CBN database. Computable, human-readable biological networks with a structured syntax are a powerful way of representing biological information generated from high-density data. This article presents sbv IMPROVER, a crowd-verification approach for the visualization and expansion of biological networks.

  12. Understanding apple consumers' expectations in terms of likes and dislikes. Use of comment analysis in a cross-cultural study.

    PubMed

    Galmarini, M V; Symoneaux, R; Chollet, S; Zamora, M C

    2013-03-01

    Apple consumers' expectations in Argentina and France were studied by comment analysis of open-ended questions. In an on-line survey consumers stated: attributes which defined quality in an apple; visual, flavor and texture characteristics they liked/did not like to find in an apple. Influence of country, consumption frequency and cultivar knowledge were analyzed by contingency tables, Chi-square per cell tests and Multiple Factor Analysis. Consumers' quality expectations were not the same in both countries. Argentineans and French consumers agreed that quality apples should be juicy (most used term in both countries), tasty, firm and fresh. However, for Argentineans quality was more related to visual characteristics, whereas for French it was driven by flavor. Argentineans used more words but French were more specific, particularly for flavour description. Moreover, frequency of consumption, varieties knowledge and the number of terms given were highly related. Frequent consumers knew more varieties and were more prolific in relation to flavour. Less frequent consumers knew fewer apple varieties and gave more words in the visual category. The use of comment analysis allowed identifying the terms that consumers used in their day to day life to describe apples, finding separately likes and dislikes, in spite of the different languages. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Low-cost, high-resolution scanning laser ophthalmoscope for the clinical environment

    NASA Astrophysics Data System (ADS)

    Soliz, P.; Larichev, A.; Zamora, G.; Murillo, S.; Barriga, E. S.

    2010-02-01

    Researchers have sought to gain greater insight into the mechanisms of the retina and the optic disc at high spatial resolutions that would enable the visualization of small structures such as photoreceptors and nerve fiber bundles. The sources of retinal image quality degradation are aberrations within the human eye, which limit the achievable resolution and the contrast of small image details. To overcome these fundamental limitations, researchers have been applying adaptive optics (AO) techniques to correct for the aberrations. Today, deformable mirror based adaptive optics devices have been developed to overcome the limitations of standard fundus cameras, but at prices that are typically unaffordable for most clinics. In this paper we demonstrate a clinically viable fundus camera with auto-focus and astigmatism correction that is easy to use and has improved resolution. We have shown that removal of low-order aberrations results in significantly better resolution and quality images. Additionally, through the application of image restoration and super-resolution techniques, the images present considerably improved quality. The improvements lead to enhanced visualization of retinal structures associated with pathology.

  14. Clinical Rating of Movement-Pattern Quality in Patients With Femoroacetabular Impingement Syndrome: A Methodological Study.

    PubMed

    Casartelli, Nicola C; Maffiuletti, Nicola A; Brunner, Romana; Büchi, Marcel; Sutter, Reto; Pfirrmann, Christian W; Naal, Florian D; Leunig, Michael; Bizzini, Mario

    2018-04-01

    Study Design Cross-sectional study. Objectives To evaluate intrarater and interrater agreement among physical therapists with different clinical experience in performing a visual rating of movement-pattern quality of patients with femoroacetabular impingement (FAI) syndrome using a semi-quantitative scale. Background Visual rating of movement patterns in patients with FAI syndrome is of interest, because poor control of dynamic hip motion is frequently noted. Methods A video camera was used to record the performance of 34 patients with FAI syndrome performing single-limb standing, squat, frontal lunge, hop lunge, bridge, and plank. Visual rating of movement, as recorded on video, was performed by a highly experienced, a moderately experienced, and a novice physical therapist on 2 occasions using a semi-quantitative scale. Hip abductor strength was assessed using dynamometry, and hip pain and function were assessed with a patient-reported questionnaire. Intrarater and interrater agreement among physical therapists was evaluated using Gwet's agreement coefficient 1. Construct validity was evaluated as the association between physical therapists' rating and patients' hip abductor strength, pain, and function. Results Good intrarater and interrater agreement was observed in the highly experienced and moderately experienced physical therapists when rating single-limb standing, bridge, and plank. Poor to moderate intrarater and interrater agreement was found when they rated squat, frontal lunge, and hop lunge. Poor performers, as rated by the highly experienced physical therapist only, demonstrated lower hip abductor strength (P<.05), and similar hip pain and hip function compared to those of good performers. Conclusion Movement-pattern quality of patients with FAI syndrome should be rated by a highly experienced physical therapist. J Orthop Sports Phys Ther 2018;48(4):260-269. doi:10.2519/jospt.2018.7840.

  15. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  16. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking

    PubMed Central

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS

    2018-01-01

    Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603

  17. Review and Evaluation of Mindfulness-Based iPhone Apps

    PubMed Central

    Kavanagh, David J; Hides, Leanne; Stoyanov, Stoyan R

    2015-01-01

    Background There is growing evidence for the positive impact of mindfulness on wellbeing. Mindfulness-based mobile apps may have potential as an alternative delivery medium for training. While there are hundreds of such apps, there is little information on their quality. Objective This study aimed to conduct a systematic review of mindfulness-based iPhone mobile apps and to evaluate their quality using a recently-developed expert rating scale, the Mobile Application Rating Scale (MARS). It also aimed to describe features of selected high-quality mindfulness apps. Methods A search for “mindfulness” was conducted in iTunes and Google Apps Marketplace. Apps that provided mindfulness training and education were included. Those containing only reminders, timers or guided meditation tracks were excluded. An expert rater reviewed and rated app quality using the MARS engagement, functionality, visual aesthetics, information quality and subjective quality subscales. A second rater provided MARS ratings on 30% of the apps for inter-rater reliability purposes. Results The “mindfulness” search identified 700 apps. However, 94 were duplicates, 6 were not accessible and 40 were not in English. Of the remaining 560, 23 apps met inclusion criteria and were reviewed. The median MARS score was 3.2 (out of 5.0), which exceeded the minimum acceptable score (3.0). The Headspace app had the highest average score (4.0), followed by Smiling Mind (3.7), iMindfulness (3.5) and Mindfulness Daily (3.5). There was a high level of inter-rater reliability between the two MARS raters. Conclusions Though many apps claim to be mindfulness-related, most were guided meditation apps, timers, or reminders. Very few had high ratings on the MARS subscales of visual aesthetics, engagement, functionality or information quality. Little evidence is available on the efficacy of the apps in developing mindfulness. PMID:26290327

  18. Review and Evaluation of Mindfulness-Based iPhone Apps.

    PubMed

    Mani, Madhavan; Kavanagh, David J; Hides, Leanne; Stoyanov, Stoyan R

    2015-08-19

    There is growing evidence for the positive impact of mindfulness on wellbeing. Mindfulness-based mobile apps may have potential as an alternative delivery medium for training. While there are hundreds of such apps, there is little information on their quality. This study aimed to conduct a systematic review of mindfulness-based iPhone mobile apps and to evaluate their quality using a recently-developed expert rating scale, the Mobile Application Rating Scale (MARS). It also aimed to describe features of selected high-quality mindfulness apps. A search for "mindfulness" was conducted in iTunes and Google Apps Marketplace. Apps that provided mindfulness training and education were included. Those containing only reminders, timers or guided meditation tracks were excluded. An expert rater reviewed and rated app quality using the MARS engagement, functionality, visual aesthetics, information quality and subjective quality subscales. A second rater provided MARS ratings on 30% of the apps for inter-rater reliability purposes. The "mindfulness" search identified 700 apps. However, 94 were duplicates, 6 were not accessible and 40 were not in English. Of the remaining 560, 23 apps met inclusion criteria and were reviewed. The median MARS score was 3.2 (out of 5.0), which exceeded the minimum acceptable score (3.0). The Headspace app had the highest average score (4.0), followed by Smiling Mind (3.7), iMindfulness (3.5) and Mindfulness Daily (3.5). There was a high level of inter-rater reliability between the two MARS raters. Though many apps claim to be mindfulness-related, most were guided meditation apps, timers, or reminders. Very few had high ratings on the MARS subscales of visual aesthetics, engagement, functionality or information quality. Little evidence is available on the efficacy of the apps in developing mindfulness.

  19. Sensory and rapid instrumental methods as a combined tool for quality control of cooked ham.

    PubMed

    Barbieri, Sara; Soglia, Francesca; Palagano, Rosa; Tesini, Federica; Bendini, Alessandra; Petracci, Massimiliano; Cavani, Claudio; Gallina Toschi, Tullia

    2016-11-01

    In this preliminary investigation, different commercial categories of Italian cooked pork hams have been characterized using an integrated approach based on both sensory and fast instrumental measurements. For these purposes, Italian products belonging to different categories (cooked ham, "selected" cooked ham and "high quality" cooked ham) were evaluated by sensory descriptive analysis and by the application of rapid tools such as image analysis by an "electronic eye" and texture analyzer. The panel of trained assessors identified and evaluated 10 sensory descriptors able to define the quality of the products. Statistical analysis highlighted that sensory characteristics related to appearance and texture were the most significant in discriminating samples belonged to the highest (high quality cooked hams) and the lowest (cooked hams) quality of the product whereas the selected cooked hams, showed intermediate characteristics. In particular, high quality samples were characterized, above all, by the highest intensity of pink intensity, typical appearance and cohesiveness, and, at the same time, by the lowest intensity of juiciness; standard cooked ham samples showed the lowest intensity of all visual attributes and the highest value of juiciness, whereas the intermediate category (selected cooked ham) was not discriminated from the other. Also physical-rheological parameters measured by electronic eye and texture analyzer were effective in classifying samples. In particular, the PLS model built with data obtained from the electronic eye showed a satisfactory performance in terms of prediction of the pink intensity and presence of fat attributes evaluated during the sensory visual phase. This study can be considered a first application of this combined approach that could represent a suitable and fast method to verify if the meat product purchased by consumer match its description in terms of compliance with the claimed quality.

  20. An algorithm for encryption of secret images into meaningful images

    NASA Astrophysics Data System (ADS)

    Kanso, A.; Ghebleh, M.

    2017-03-01

    Image encryption algorithms typically transform a plain image into a noise-like cipher image, whose appearance is an indication of encrypted content. Bao and Zhou [Image encryption: Generating visually meaningful encrypted images, Information Sciences 324, 2015] propose encrypting the plain image into a visually meaningful cover image. This improves security by masking existence of encrypted content. Following their approach, we propose a lossless visually meaningful image encryption scheme which improves Bao and Zhou's algorithm by making the encrypted content, i.e. distortions to the cover image, more difficult to detect. Empirical results are presented to show high quality of the resulting images and high security of the proposed algorithm. Competence of the proposed scheme is further demonstrated by means of comparison with Bao and Zhou's scheme.

  1. Sleep Disturbances among Persons Who Are Visually Impaired: Survey of Dog Guide Users.

    ERIC Educational Resources Information Center

    Fouladi, Massoud K.; Moseley, Merrick J.; Jones, Helen S.; Tobin, Michael J.

    1998-01-01

    A survey completed by 1237 adults with severe visual impairments found that 20% described the quality of their sleep as poor or very poor. Exercise was associated with better sleep and depression with poorer sleep. However, visual acuity did not predict sleep quality, casting doubt on the idea that restricted visual input (light) causes sleep…

  2. The Challenges of Educating the Visually Impaired and Quality Assurance in Tertiary Institutions of Learning in Nigeria

    ERIC Educational Resources Information Center

    Omede, Andrew A.

    2015-01-01

    This paper focused on the challenges in educating the visually impaired and modalities for ensuring quality assurance in tertiary institutions of learning in Nigeria. It examined the global challenges in the higher educational system and made it clear that the visually impaired are those with visual problems be it partial, low vision, or total…

  3. Linking microarray reporters with protein functions.

    PubMed

    Gaj, Stan; van Erk, Arie; van Haaften, Rachel I M; Evelo, Chris T A

    2007-09-26

    The analysis of microarray experiments requires accurate and up-to-date functional annotation of the microarray reporters to optimize the interpretation of the biological processes involved. Pathway visualization tools are used to connect gene expression data with existing biological pathways by using specific database identifiers that link reporters with elements in the pathways. This paper proposes a novel method that aims to improve microarray reporter annotation by BLASTing the original reporter sequences against a species-specific EMBL subset, that was derived from and crosslinked back to the highly curated UniProt database. The resulting alignments were filtered using high quality alignment criteria and further compared with the outcome of a more traditional approach, where reporter sequences were BLASTed against EnsEMBL followed by locating the corresponding protein (UniProt) entry for the high quality hits. Combining the results of both methods resulted in successful annotation of > 58% of all reporter sequences with UniProt IDs on two commercial array platforms, increasing the amount of Incyte reporters that could be coupled to Gene Ontology terms from 32.7% to 58.3% and to a local GenMAPP pathway from 9.6% to 16.7%. For Agilent, 35.3% of the total reporters are now linked towards GO nodes and 7.1% on local pathways. Our methods increased the annotation quality of microarray reporter sequences and allowed us to visualize more reporters using pathway visualization tools. Even in cases where the original reporter annotation showed the correct description the new identifiers often allowed improved pathway and Gene Ontology linking. These methods are freely available at http://www.bigcat.unimaas.nl/public/publications/Gaj_Annotation/.

  4. Modulation of Visually Evoked Postural Responses by Contextual Visual, Haptic and Auditory Information: A ‘Virtual Reality Check’

    PubMed Central

    Meyer, Georg F.; Shao, Fei; White, Mark D.; Hopkins, Carl; Robotham, Antony J.

    2013-01-01

    Externally generated visual motion signals can cause the illusion of self-motion in space (vection) and corresponding visually evoked postural responses (VEPR). These VEPRs are not simple responses to optokinetic stimulation, but are modulated by the configuration of the environment. The aim of this paper is to explore what factors modulate VEPRs in a high quality virtual reality (VR) environment where real and virtual foreground objects served as static visual, auditory and haptic reference points. Data from four experiments on visually evoked postural responses show that: 1) visually evoked postural sway in the lateral direction is modulated by the presence of static anchor points that can be haptic, visual and auditory reference signals; 2) real objects and their matching virtual reality representations as visual anchors have different effects on postural sway; 3) visual motion in the anterior-posterior plane induces robust postural responses that are not modulated by the presence of reference signals or the reality of objects that can serve as visual anchors in the scene. We conclude that automatic postural responses for laterally moving visual stimuli are strongly influenced by the configuration and interpretation of the environment and draw on multisensory representations. Different postural responses were observed for real and virtual visual reference objects. On the basis that automatic visually evoked postural responses in high fidelity virtual environments should mimic those seen in real situations we propose to use the observed effect as a robust objective test for presence and fidelity in VR. PMID:23840760

  5. Femtosecond-Assisted LASIK Versus PRK: Comparison of 6-Month Visual Acuity and Quality Outcome for High Myopia.

    PubMed

    Hashemi, Hassan; Miraftab, Mohammad; Ghaffari, Reza; Asgari, Soheila

    2016-11-01

    To compare the results of femtosecond-assisted laser in situ keratomileusis (femto-LASIK) and photorefractive keratectomy with mitomycin C (PRK-MMC) for the correction of myopia more than 7.0 diopters (D). In this comparative nonrandomized trial, 60 eyes (30 eyes in each group) were enrolled. Patients were tested for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal aberrations, and contrast sensitivity (CS) before surgery and at 3 and 6 months postoperatively. Mean preoperative myopia was -8.65±1.51 and -8.04±1.70 D in the femto-LASIK and PRK-MMC groups, respectively (P=0.149). Intergroup differences in baseline indices were not statistically significant. At 6 months after surgery, UDVA showed an improving trend, but it was better in the femto-LASIK group (P=0.026). CDVA in the two groups remained similarly unchanged (P=0.170). For the femto-LASIK and PRK-MMC groups, the safety indices were 1.01±0.05 and 1.01±0.14 (P=0.949), respectively, and the efficacy indices were 0.99±0.07 and 0.93±0.22 (P=0.192), respectively. Comparing CS, only CS18 showed a significantly greater decrease in the femto-LASIK group compared with the PRK-MMC group (P=0.016). Intergroup differences were not statistically significant in other spatial frequencies. Changes in the ocular and corneal higher order aberrations were not statistically different between the two groups except ocular coma, which increased in the femto-LASIK group (P=0.041). Femto-LASIK improves UDVA better than PRK-MMC in high myopia. However, because of increased coma, the quality of vision is reduced. In other words, visual acuity outcome is better with femto-LASIK and visual quality outcome is better with PRK-MMC.

  6. Case studies in machine vision integration

    NASA Astrophysics Data System (ADS)

    Ahlers, Rolf-Juergen

    1991-09-01

    Many countries in the world, e.g. Germany and Japan, depend on high export rates. It is therefore necessary for them to strive for a high degree of quality in the products and processes exported. The example of Japan shows in a significant manner that a competitor should not be feared just because he can offer cheaper products. They become a "source of danger" when these products also achieve a high degree of quality. Thus, survival in the market depends on the ability to recognize the implications of technical and economic developments, to draw the perhaps unpopular conclusions for production, and to make the right decisions. This particularly applies to measurement and inspection equipment for quality control. Here, besides electro-optical sensors in general, image processing systems play an important role because they can emulate the conventional form of visual inspection by a human operator — i.e., the methods used in industry when dealing with quality inspection and control. In combination with precision indexing tables and industrial robots, image processing systems can be extended to new fields of application. The great awareness of the potential applications of vision and image processing systems has led to a variety of realized applications, some of which will be described below under three topics: • electro-optical measurement systems, • automation of visual inspection tasks, and • robot guidance.

  7. Integrating automated support for a software management cycle into the TAME system

    NASA Technical Reports Server (NTRS)

    Sunazuka, Toshihiko; Basili, Victor R.

    1989-01-01

    Software managers are interested in the quantitative management of software quality, cost and progress. An integrated software management methodology, which can be applied throughout the software life cycle for any number purposes, is required. The TAME (Tailoring A Measurement Environment) methodology is based on the improvement paradigm and the goal/question/metric (GQM) paradigm. This methodology helps generate a software engineering process and measurement environment based on the project characteristics. The SQMAR (software quality measurement and assurance technology) is a software quality metric system and methodology applied to the development processes. It is based on the feed forward control principle. Quality target setting is carried out before the plan-do-check-action activities are performed. These methodologies are integrated to realize goal oriented measurement, process control and visual management. A metric setting procedure based on the GQM paradigm, a management system called the software management cycle (SMC), and its application to a case study based on NASA/SEL data are discussed. The expected effects of SMC are quality improvement, managerial cost reduction, accumulation and reuse of experience, and a highly visual management reporting system.

  8. Direct-to-consumer advertising via the Internet: the role of Web site design.

    PubMed

    Sewak, Saurabh S; Wilkin, Noel E; Bentley, John P; Smith, Mickey C

    2005-06-01

    Recent attempts to propose criteria for judging the quality of pharmaceutical and healthcare Web sites do not distinguish between attributes of Web site design related to content and other attributes not related to the content. The Elaboration Likelihood Model from persuasion literature is used as a framework for investigating the effects of Web site design on consequents like attitude and knowledge acquisition. A between-subjects, 2 (high or low involvement)x2 (Web site designed with high or low aspects of visual appeal) factorial design was used in this research. College students were randomly assigned to these treatment groups yielding a balanced design with 29 observations per treatment cell. Analysis of variance results for the effects of involvement and Web site design on attitude and knowledge indicated that the interaction between the independent variables was not significant in both analyses. Examination of main effects revealed that participants who viewed the Web site with higher visual appeal actually had slightly lower knowledge scores (6.32) than those who viewed the Web site with lower visual appeal (7.03, F(1,112)=3.827, P=.053). Results of this research seem to indicate that aspects of Web site design (namely aspects of visual appeal and quality) may not play a role in attaining desired promotional objectives, which can include development of favorable attitudes toward the product and facilitating knowledge acquisition.

  9. [Relationship between image quality and cross-sectional area of phantom in three-dimensional positron emission tomography scan].

    PubMed

    Osawa, Atsushi; Miwa, Kenta; Wagatsuma, Kei; Takiguchi, Tomohiro; Tamura, Shintaro; Akimoto, Kenta

    2012-01-01

    The image quality in (18)FDG PET/CT often degrades as the body size increases. The purpose of this study was to evaluate the relationship between image quality and the body size using original phantoms of variable cross-sectional areas in PET/CT. We produced five water phantoms with different cross-sectional areas. The long axis of phantom was 925 mm, and the cross-sectional area was from 324 to 1189 cm(2). These phantoms with the sphere (diameter 10 mm) were filled with (18)F-FDG solution. The radioactivity concentration of background in the phantom was 1.37, 2.73, 4.09 and 5.46 kBq/mL. The scanning duration was 30 min in list mode acquisition for each measurement. Background variability (N(10 mm)), noise equivalent count rates (NECR(phantom)), hot sphere contrast (Q(H,10 mm)) as physical evaluation and visual score of sphere detection were measured, respectively. The relationship between image quality and the various cross-sectional areas was also analyzed under the above-mentioned conditions. As cross-sectional area increased, NECR(phantom) progressively decreased. Furthermore, as cross-sectional area increased, N(10 mm) increased and Q(H,10 mm) decreased. Image quality became degraded as body weight increased because noise and contrast contributed to image quality. The visual score of sphere detection deteriorated in high background radioactivity concentration because a false positive detection in cross-sectional area of the phantom increased. However, additional increases in scanning periods could improve the visual score. We assessed tendencies in the relationship between image quality and body size in PET/CT. Our results showed that time adjustment was more effective than dose adjustment for stable image quality of heavier patients in terms of the large cross-sectional area.

  10. Perceived assessment metrics for visible and infrared color fused image quality without reference image

    NASA Astrophysics Data System (ADS)

    Yu, Xuelian; Chen, Qian; Gu, Guohua; Ren, Jianle; Sui, Xiubao

    2015-02-01

    Designing objective quality assessment of color-fused image is a very demanding and challenging task. We propose four no-reference metrics based on human visual system characteristics for objectively evaluating the quality of false color fusion image. The perceived edge metric (PEM) is defined based on visual perception model and color image gradient similarity between the fused image and the source images. The perceptual contrast metric (PCM) is established associating multi-scale contrast and varying contrast sensitivity filter (CSF) with color components. The linear combination of the standard deviation and mean value over the fused image construct the image colorfulness metric (ICM). The color comfort metric (CCM) is designed by the average saturation and the ratio of pixels with high and low saturation. The qualitative and quantitative experimental results demonstrate that the proposed metrics have a good agreement with subjective perception.

  11. Prostate seed implant quality assessment using MR and CT image fusion.

    PubMed

    Amdur, R J; Gladstone, D; Leopold, K A; Harris, R D

    1999-01-01

    After a seed implant of the prostate, computerized tomography (CT) is ideal for determining seed distribution but soft tissue anatomy is frequently not well visualized. Magnetic resonance (MR) images soft tissue anatomy well but seed visualization is problematic. We describe a method of fusing CT and MR images to exploit the advantages of both of these modalities when assessing the quality of a prostate seed implant. Eleven consecutive prostate seed implant patients were imaged with axial MR and CT scans. MR and CT images were fused in three dimensions using the Pinnacle 3.0 version of the ADAC treatment planning system. The urethra and bladder base were used to "line up" MR and CT image sets during image fusion. Alignment was accomplished using translation and rotation in the three ortho-normal planes. Accuracy of image fusion was evaluated by calculating the maximum deviation in millimeters between the center of the urethra on axial MR versus CT images. Implant quality was determined by comparing dosimetric results to previously set parameters. Image fusion was performed with a high degree of accuracy. When lining up the urethra and base of bladder, the maximum difference in axial position of the urethra between MR and CT averaged 2.5 mm (range 1.3-4.0 mm, SD 0.9 mm). By projecting CT-derived dose distributions over MR images of soft tissue structures, qualitative and quantitative evaluation of implant quality is straightforward. The image-fusion process we describe provides a sophisticated way of assessing the quality of a prostate seed implant. Commercial software makes the process time-efficient and available to any clinical practice with a high-quality treatment planning system. While we use MR to image soft tissue structures, the process could be used with any imaging modality that is able to visualize the prostatic urethra (e.g., ultrasound).

  12. Visualizing the Quality of Vectur Features - a Proposal for Cadastral Maps

    NASA Astrophysics Data System (ADS)

    Navratil, G.; Leopoldseder, V.

    2017-09-01

    A well-known problem of geographical information is the communication of the quality level. It can be either done verbally / numerically or it can be done graphically. The graphical form is especially useful if the quality has a spatial variation because the spatial distribution is visualized as well. The problem of spatial variation of quality is an issue for cadastral maps. Non-experts cannot determine the quality at a specific location. Therefore a visual representation was tested for the Austrian cadastre. A map sheet was redesigned to give some indication of cadastral quality and presented to both experts and non-experts. The paper presents the result of the interviews.

  13. Water surface modeling from a single viewpoint video.

    PubMed

    Li, Chuan; Pickup, David; Saunders, Thomas; Cosker, Darren; Marshall, David; Hall, Peter; Willis, Philip

    2013-07-01

    We introduce a video-based approach for producing water surface models. Recent advances in this field output high-quality results but require dedicated capturing devices and only work in limited conditions. In contrast, our method achieves a good tradeoff between the visual quality and the production cost: It automatically produces a visually plausible animation using a single viewpoint video as the input. Our approach is based on two discoveries: first, shape from shading (SFS) is adequate to capture the appearance and dynamic behavior of the example water; second, shallow water model can be used to estimate a velocity field that produces complex surface dynamics. We will provide qualitative evaluation of our method and demonstrate its good performance across a wide range of scenes.

  14. Indirect gonioscopy system for imaging iridocorneal angle of eye

    NASA Astrophysics Data System (ADS)

    Perinchery, Sandeep M.; Fu, Chan Yiu; Baskaran, Mani; Aung, Tin; Murukeshan, V. M.

    2017-08-01

    Current clinical optical imaging systems do not provide sufficient structural information of trabecular meshwork (TM) in the iridocorneal angle (ICA) of the eye due to their low resolution. Increase in the intraocular pressure (IOP) can occur due to the abnormalities in TM, which could subsequently lead to glaucoma. Here, we present an indirect gonioscopy based imaging probe with significantly improved visualization of structures in the ICA including TM region, compared to the currently available tools. Imaging quality of the developed system was tested in porcine samples. Improved direct high quality visualization of the TM region through this system can be used for Laser trabeculoplasty, which is a primary treatment of glaucoma. This system is expected to be used complementary to angle photography and gonioscopy.

  15. Visualization of risk structures for interactive planning of image guided radiofrequency ablation of liver tumors

    NASA Astrophysics Data System (ADS)

    Rieder, Christian; Schwier, Michael; Weihusen, Andreas; Zidowitz, Stephan; Peitgen, Heinz-Otto

    2009-02-01

    Image guided radiofrequency ablation (RFA) is becoming a standard procedure as a minimally invasive method for tumor treatment in the clinical routine. The visualization of pathological tissue and potential risk structures like vessels or important organs gives essential support in image guided pre-interventional RFA planning. In this work our aim is to present novel visualization techniques for interactive RFA planning to support the physician with spatial information of pathological structures as well as the finding of trajectories without harming vitally important tissue. Furthermore, we illustrate three-dimensional applicator models of different manufactures combined with corresponding ablation areas in homogenous tissue, as specified by the manufacturers, to enhance the estimated amount of cell destruction caused by ablation. The visualization techniques are embedded in a workflow oriented application, designed for the use in the clinical routine. To allow a high-quality volume rendering we integrated a visualization method using the fuzzy c-means algorithm. This method automatically defines a transfer function for volume visualization of vessels without the need of a segmentation mask. However, insufficient visualization results of the displayed vessels caused by low data quality can be improved using local vessel segmentation in the vicinity of the lesion. We also provide an interactive segmentation technique of liver tumors for the volumetric measurement and for the visualization of pathological tissue combined with anatomical structures. In order to support coagulation estimation with respect to the heat-sink effect of the cooling blood flow which decreases thermal ablation, a numerical simulation of the heat distribution is provided.

  16. Randomized Crossover Trial of Silicone Hydrogel Presbyopic Contact Lenses.

    PubMed

    Sivardeen, Ahmed; Laughton, Deborah; Wolffsohn, James S

    2016-02-01

    To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p < 0.001), stereopsis (p < 0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.

  17. Applications of Java and Vector Graphics to Astrophysical Visualization

    NASA Astrophysics Data System (ADS)

    Edirisinghe, D.; Budiardja, R.; Chae, K.; Edirisinghe, G.; Lingerfelt, E.; Guidry, M.

    2002-12-01

    We describe a series of projects utilizing the portability of Java programming coupled with the compact nature of vector graphics (SVG and SWF formats) for setup and control of calculations, local and collaborative visualization, and interactive 2D and 3D animation presentations in astrophysics. Through a set of examples, we demonstrate how such an approach can allow efficient and user-friendly control of calculations in compiled languages such as Fortran 90 or C++ through portable graphical interfaces written in Java, and how the output of such calculations can be packaged in vector-based animation having interactive controls and extremely high visual quality, but very low bandwidth requirements.

  18. Tele-transmission of stereoscopic images of the optic nerve head in glaucoma via Internet.

    PubMed

    Bergua, Antonio; Mardin, Christian Y; Horn, Folkert K

    2009-06-01

    The objective was to describe an inexpensive system to visualize stereoscopic photographs of the optic nerve head on computer displays and to transmit such images via the Internet for collaborative research or remote clinical diagnosis in glaucoma. Stereoscopic images of glaucoma patients were digitized and stored in a file format (joint photographic stereoimage [jps]) containing all three-dimensional information for both eyes on an Internet Web site (www.trizax.com). The size of jps files was between 0.4 to 1.4 MB (corresponding to a diagonal stereo image size between 900 and 1400 pixels) suitable for Internet protocols. A conventional personal computer system equipped with wireless stereoscopic LCD shutter glasses and a CRT-monitor with high refresh rate (120 Hz) can be used to obtain flicker-free stereo visualization of true-color images with high resolution. Modern thin-film transistor-LCD displays in combination with inexpensive red-cyan goggles achieve stereoscopic visualization with the same resolution but reduced color quality and contrast. The primary aim of our study was met to transmit stereoscopic images via the Internet. Additionally, we found that with both stereoscopic visualization techniques, cup depth, neuroretinal rim shape, and slope of the inner wall of the optic nerve head, can be qualitatively better perceived and interpreted than with monoscopic images. This study demonstrates high-quality and low-cost Internet transmission of stereoscopic images of the optic nerve head from glaucoma patients. The technique allows exchange of stereoscopic images and can be applied to tele-diagnostic and glaucoma research.

  19. SU-G-201-16: Thermal Imaging in Source Visualization and Radioactivity Measurement for High Dose Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, X; Lei, Y; Zheng, D

    2016-06-15

    Purpose: High Dose Rate (HDR) brachytherapy poses a special challenge to radiation safety and quality assurance (QA) due to its high radioactivity, and it is thus critical to verify the HDR source location and its radioactive strength. This study demonstrates a new method for measuring HDR source location and radioactivity utilizing thermal imaging. A potential application would relate to HDR QA and safety improvement. Methods: Heating effects by an HDR source were studied using Finite Element Analysis (FEA). Thermal cameras were used to visualize an HDR source inside a plastic applicator made of polyvinylidene difluoride (PVDF). Using different source dwellmore » times, correlations between the HDR source strength and heating effects were studied, thus establishing potential daily QA criteria using thermal imaging Results: For an Ir1?2 source with a radioactivity of 10 Ci, the decay-induced heating power inside the source is ∼13.3 mW. After the HDR source was extended into the PVDF applicator and reached thermal equilibrium, thermal imaging visualized the temperature gradient of 10 K/cm along the PVDF applicator surface, which agreed with FEA modeling. For Ir{sup 192} source activities ranging from 4.20–10.20 Ci, thermal imaging could verify source activity with an accuracy of 6.3% with a dwell time of 10 sec, and an accuracy of 2.5 % with 100 sec. Conclusion: Thermal imaging is a feasible tool to visualize HDR source dwell positions and verify source integrity. Patient safety and treatment quality will be improved by integrating thermal measurements into HDR QA procedures.« less

  20. 3D Visualization for Phoenix Mars Lander Science Operations

    NASA Technical Reports Server (NTRS)

    Edwards, Laurence; Keely, Leslie; Lees, David; Stoker, Carol

    2012-01-01

    Planetary surface exploration missions present considerable operational challenges in the form of substantial communication delays, limited communication windows, and limited communication bandwidth. A 3D visualization software was developed and delivered to the 2008 Phoenix Mars Lander (PML) mission. The components of the system include an interactive 3D visualization environment called Mercator, terrain reconstruction software called the Ames Stereo Pipeline, and a server providing distributed access to terrain models. The software was successfully utilized during the mission for science analysis, site understanding, and science operations activity planning. A terrain server was implemented that provided distribution of terrain models from a central repository to clients running the Mercator software. The Ames Stereo Pipeline generates accurate, high-resolution, texture-mapped, 3D terrain models from stereo image pairs. These terrain models can then be visualized within the Mercator environment. The central cross-cutting goal for these tools is to provide an easy-to-use, high-quality, full-featured visualization environment that enhances the mission science team s ability to develop low-risk productive science activity plans. In addition, for the Mercator and Viz visualization environments, extensibility and adaptability to different missions and application areas are key design goals.

  1. Fuels planning: science synthesis and integration; social issues fact sheet 16: Prescribed fire and visual quality

    Treesearch

    Christine Esposito

    2006-01-01

    Research shows that, while prescribed burning and other fuels treatments can lower visual quality in some situations, they can also improve it in others. This fact sheet reviews the visual aspects of different levels of prescribed burning.Other publications in this series...

  2. Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index.

    PubMed

    Xue, Wufeng; Zhang, Lei; Mou, Xuanqin; Bovik, Alan C

    2014-02-01

    It is an important task to faithfully evaluate the perceptual quality of output images in many applications, such as image compression, image restoration, and multimedia streaming. A good image quality assessment (IQA) model should not only deliver high quality prediction accuracy, but also be computationally efficient. The efficiency of IQA metrics is becoming particularly important due to the increasing proliferation of high-volume visual data in high-speed networks. We present a new effective and efficient IQA model, called gradient magnitude similarity deviation (GMSD). The image gradients are sensitive to image distortions, while different local structures in a distorted image suffer different degrees of degradations. This motivates us to explore the use of global variation of gradient based local quality map for overall image quality prediction. We find that the pixel-wise gradient magnitude similarity (GMS) between the reference and distorted images combined with a novel pooling strategy-the standard deviation of the GMS map-can predict accurately perceptual image quality. The resulting GMSD algorithm is much faster than most state-of-the-art IQA methods, and delivers highly competitive prediction accuracy. MATLAB source code of GMSD can be downloaded at http://www4.comp.polyu.edu.hk/~cslzhang/IQA/GMSD/GMSD.htm.

  3. Web-based decision support and visualization tools for water quality management in the Chesapeake Bay watershed

    USGS Publications Warehouse

    Mullinix, C.; Hearn, P.; Zhang, H.; Aguinaldo, J.

    2009-01-01

    Federal, State, and local water quality managers charged with restoring the Chesapeake Bay ecosystem require tools to maximize the impact of their limited resources. To address this need, the U.S. Geological Survey (USGS) and the Environmental Protection Agency's Chesapeake Bay Program (CBP) are developing a suite of Web-based tools called the Chesapeake Online Assessment Support Toolkit (COAST). The goal of COAST is to help CBP partners identify geographic areas where restoration activities would have the greatest effect, select the appropriate management strategies, and improve coordination and prioritization among partners. As part of the COAST suite of tools focused on environmental restoration, a water quality management visualization component called the Nutrient Yields Mapper (NYM) tool is being developed by USGS. The NYM tool is a web application that uses watershed yield estimates from USGS SPAtially Referenced Regressions On Watershed (SPARROW) attributes model (Schwarz et al., 2006) [6] to allow water quality managers to identify important sources of nitrogen and phosphorous within the Chesapeake Bay watershed. The NYM tool utilizes new open source technologies that have become popular in geospatial web development, including components such as OpenLayers and GeoServer. This paper presents examples of water quality data analysis based on nutrient type, source, yield, and area of interest using the NYM tool for the Chesapeake Bay watershed. In addition, we describe examples of map-based techniques for identifying high and low nutrient yield areas; web map engines; and data visualization and data management techniques.

  4. Power profiles and short-term visual performance of soft contact lenses.

    PubMed

    Papas, Eric; Dahms, Anne; Carnt, Nicole; Tahhan, Nina; Ehrmann, Klaus

    2009-04-01

    To investigate the manner in which contemporary soft contact lenses differ in the distribution of optical power within their optic zones and establish if these variations affect the vision of wearers or the prescribing procedure for back vertex power (BVP). By using a Visionix VC 2001 contact lens power analyzer, power profiles were measured across the optic zones of the following contemporary contact lenses ACUVUE 2, ACUVUE ADVANCE, O2OPTIX, NIGHT & DAY and PureVision. Single BVP measures were obtained using a Nikon projection lensometer. Visual performance was assessed in 28 masked subjects who wore each lens type in random order. Measurements taken were high and low contrast visual acuity in normal illumination (250 Cd/m), high contrast acuity in reduced illumination (5 Cd/m), subjective visual quality using a numerical rating scale, and visual satisfaction rating using a Likert scale. Marked differences in the distribution of optical power across the optic zone were evident among the lens types. No significant differences were found for any of the visual performance variables (p > 0.05, analysis of variance with repeated measures and Friedman test). Variations in power profile between contemporary soft lens types exist but do not, in general, result in measurable visual performance differences in the short term, nor do they substantially influence the BVP required for optimal correction.

  5. Computable visually observed phenotype ontological framework for plants

    PubMed Central

    2011-01-01

    Background The ability to search for and precisely compare similar phenotypic appearances within and across species has vast potential in plant science and genetic research. The difficulty in doing so lies in the fact that many visual phenotypic data, especially visually observed phenotypes that often times cannot be directly measured quantitatively, are in the form of text annotations, and these descriptions are plagued by semantic ambiguity, heterogeneity, and low granularity. Though several bio-ontologies have been developed to standardize phenotypic (and genotypic) information and permit comparisons across species, these semantic issues persist and prevent precise analysis and retrieval of information. A framework suitable for the modeling and analysis of precise computable representations of such phenotypic appearances is needed. Results We have developed a new framework called the Computable Visually Observed Phenotype Ontological Framework for plants. This work provides a novel quantitative view of descriptions of plant phenotypes that leverages existing bio-ontologies and utilizes a computational approach to capture and represent domain knowledge in a machine-interpretable form. This is accomplished by means of a robust and accurate semantic mapping module that automatically maps high-level semantics to low-level measurements computed from phenotype imagery. The framework was applied to two different plant species with semantic rules mined and an ontology constructed. Rule quality was evaluated and showed high quality rules for most semantics. This framework also facilitates automatic annotation of phenotype images and can be adopted by different plant communities to aid in their research. Conclusions The Computable Visually Observed Phenotype Ontological Framework for plants has been developed for more efficient and accurate management of visually observed phenotypes, which play a significant role in plant genomics research. The uniqueness of this framework is its ability to bridge the knowledge of informaticians and plant science researchers by translating descriptions of visually observed phenotypes into standardized, machine-understandable representations, thus enabling the development of advanced information retrieval and phenotype annotation analysis tools for the plant science community. PMID:21702966

  6. Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs.

    PubMed

    Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J

    2012-02-01

    To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.

  7. Acute optic neuritis

    PubMed Central

    Galetta, Steven L.; Villoslada, Pablo; Levin, Netta; Shindler, Kenneth; Ishikawa, Hiroshi; Parr, Edward; Cadavid, Diego

    2015-01-01

    Idiopathic demyelinating optic neuritis (ON) most commonly presents as acute unilateral vision loss and eye pain and is frequently associated with multiple sclerosis. Although emphasis is often placed on the good recovery of high-contrast visual acuity, persistent deficits are frequently observed in other aspects of vision, including contrast sensitivity, visual field testing, color vision, motion perception, and vision-related quality of life. Persistent and profound structural and functional changes are often revealed by imaging and electrophysiologic techniques, including optical coherence tomography, visual-evoked potentials, and nonconventional MRI. These abnormalities can impair patients' abilities to perform daily activities (e.g., driving, working) so they have important implications for patients' quality of life. In this article, we review the sequelae from ON, including clinical, structural, and functional changes and their interrelationships. The unmet needs in each of these areas are considered and the progress made toward meeting those needs is examined. Finally, we provide an overview of past and present investigational approaches for disease modification in ON. PMID:26236761

  8. Visual Display Terminal use in Iranian bank tellers: Effects on job stress and insomnia.

    PubMed

    Giahi, Omid; Shahmoradi, Behzad; Barkhordari, Abdullah; Khoubi, Jamshid

    2015-01-01

    Visual Display Terminals (VDTs) are equipments in many workplaces which their use may increase the risk of visual, musculoskeletal and mental problems including insomnia. To determine the relationship between duration of daily VDT use and insomnia among the Iranian bank tellers. We randomly selected 382 bank tellers working with VDT. Quality of sleep and stress information were collected by Athens Insomnia Scales (AIS) and Demand-Control Model (DCM) model respectively. Out of 382 participants, 127 (33.2%) had sleep complaints and 255 (66.8%) had no sleep disorders. Moreover, the insomnia symptoms' score were significantly high in the participants having more than 6 hours of daily VDT use after adjusting for multiple confounding factors (P <  0.001). There was no significant relationship between stress and insomnia. It seems that the low levels of stress and job satisfaction reduce the impact of VDT on sleep quality in tellers who worked less than 6 hours per day.

  9. The association between clinical parameters and glaucoma-specific quality of life in Chinese primary open-angle glaucoma patients.

    PubMed

    Lee, Jacky W Y; Chan, Catherine W S; Chan, Jonathan C H; Li, Q; Lai, Jimmy S M

    2014-08-01

    OBJECTIVE. To investigate the association between clinical measurements and glaucoma-specific quality of life in Chinese glaucoma patients. DESIGN. Cross-sectional study. SETTING. An academic hospital in Hong Kong. PATIENTS. A Chinese translation of the Glaucoma Quality of Life-15 questionnaire was completed by 51 consecutive patients with bilateral primary open-angle glaucoma. The binocular means of several clinical measurements were correlated with Glaucoma Quality of Life-15 findings using Pearson's correlation coefficient and linear regression. The measurements were the visual field index and pattern standard deviation from the Humphrey Field Analyzer, Snellen best-corrected visual acuity, presenting intra-ocular pressure, current intra-ocular pressure, average retinal nerve fibre layer thickness via optical coherence tomography, and the number of topical anti-glaucoma medications being used. RESULTS. In these patients, there was a significant correlation and linear relationship between a poorer Glaucoma Quality of Life-15 score and a lower visual field index (r=0.3, r(2)=0.1, P=0.01) and visual acuity (r=0.3, r(2)=0.1, P=0.03). A thinner retinal nerve fibre layer also correlated with a poorer Glaucoma Quality of Life-15 score, but did not attain statistical significance (r=0.3, P=0.07). There were no statistically significant correlations for the other clinical parameters with the Glaucoma Quality of Life-15 scores (all P values being >0.7). The three most problematic activities affecting quality of life were "adjusting to bright lights", "going from a light to a dark room or vice versa", and "seeing at night". CONCLUSION. For Chinese primary open-angle glaucoma patients, binocular visual field index and visual acuity correlated linearly with glaucoma-specific quality of life, and activities involving dark adaptation were the most problematic.

  10. Lot quality assurance sampling to monitor supplemental immunization activity quality: an essential tool for improving performance in polio endemic countries.

    PubMed

    Brown, Alexandra E; Okayasu, Hiromasa; Nzioki, Michael M; Wadood, Mufti Z; Chabot-Couture, Guillaume; Quddus, Arshad; Walker, George; Sutter, Roland W

    2014-11-01

    Monitoring the quality of supplementary immunization activities (SIAs) is a key tool for polio eradication. Regular monitoring data, however, are often unreliable, showing high coverage levels in virtually all areas, including those with ongoing virus circulation. To address this challenge, lot quality assurance sampling (LQAS) was introduced in 2009 as an additional tool to monitor SIA quality. Now used in 8 countries, LQAS provides a number of programmatic benefits: identifying areas of weak coverage quality with statistical reliability, differentiating areas of varying coverage with greater precision, and allowing for trend analysis of campaign quality. LQAS also accommodates changes to survey format, interpretation thresholds, evaluations of sample size, and data collection through mobile phones to improve timeliness of reporting and allow for visualization of campaign quality. LQAS becomes increasingly important to address remaining gaps in SIA quality and help focus resources on high-risk areas to prevent the continued transmission of wild poliovirus. © Crown copyright 2014.

  11. Quality-Related Monitoring and Grading of Granulated Products by Weibull-Distribution Modeling of Visual Images with Semi-Supervised Learning.

    PubMed

    Liu, Jinping; Tang, Zhaohui; Xu, Pengfei; Liu, Wenzhong; Zhang, Jin; Zhu, Jianyong

    2016-06-29

    The topic of online product quality inspection (OPQI) with smart visual sensors is attracting increasing interest in both the academic and industrial communities on account of the natural connection between the visual appearance of products with their underlying qualities. Visual images captured from granulated products (GPs), e.g., cereal products, fabric textiles, are comprised of a large number of independent particles or stochastically stacking locally homogeneous fragments, whose analysis and understanding remains challenging. A method of image statistical modeling-based OPQI for GP quality grading and monitoring by a Weibull distribution(WD) model with a semi-supervised learning classifier is presented. WD-model parameters (WD-MPs) of GP images' spatial structures, obtained with omnidirectional Gaussian derivative filtering (OGDF), which were demonstrated theoretically to obey a specific WD model of integral form, were extracted as the visual features. Then, a co-training-style semi-supervised classifier algorithm, named COSC-Boosting, was exploited for semi-supervised GP quality grading, by integrating two independent classifiers with complementary nature in the face of scarce labeled samples. Effectiveness of the proposed OPQI method was verified and compared in the field of automated rice quality grading with commonly-used methods and showed superior performance, which lays a foundation for the quality control of GP on assembly lines.

  12. Visually lossless compression of digital hologram sequences

    NASA Astrophysics Data System (ADS)

    Darakis, Emmanouil; Kowiel, Marcin; Näsänen, Risto; Naughton, Thomas J.

    2010-01-01

    Digital hologram sequences have great potential for the recording of 3D scenes of moving macroscopic objects as their numerical reconstruction can yield a range of perspective views of the scene. Digital holograms inherently have large information content and lossless coding of holographic data is rather inefficient due to the speckled nature of the interference fringes they contain. Lossy coding of still holograms and hologram sequences has shown promising results. By definition, lossy compression introduces errors in the reconstruction. In all of the previous studies, numerical metrics were used to measure the compression error and through it, the coding quality. Digital hologram reconstructions are highly speckled and the speckle pattern is very sensitive to data changes. Hence, numerical quality metrics can be misleading. For example, for low compression ratios, a numerically significant coding error can have visually negligible effects. Yet, in several cases, it is of high interest to know how much lossy compression can be achieved, while maintaining the reconstruction quality at visually lossless levels. Using an experimental threshold estimation method, the staircase algorithm, we determined the highest compression ratio that was not perceptible to human observers for objects compressed with Dirac and MPEG-4 compression methods. This level of compression can be regarded as the point below which compression is perceptually lossless although physically the compression is lossy. It was found that up to 4 to 7.5 fold compression can be obtained with the above methods without any perceptible change in the appearance of video sequences.

  13. Effects of simulator motion and visual characteristics on rotorcraft handling qualities evaluations

    NASA Technical Reports Server (NTRS)

    Mitchell, David G.; Hart, Daniel C.

    1993-01-01

    The pilot's perceptions of aircraft handling qualities are influenced by a combination of the aircraft dynamics, the task, and the environment under which the evaluation is performed. When the evaluation is performed in a groundbased simulator, the characteristics of the simulation facility also come into play. Two studies were conducted on NASA Ames Research Center's Vertical Motion Simulator to determine the effects of simulator characteristics on perceived handling qualities. Most evaluations were conducted with a baseline set of rotorcraft dynamics, using a simple transfer-function model of an uncoupled helicopter, under different conditions of visual time delays and motion command washout filters. Differences in pilot opinion were found as the visual and motion parameters were changed, reflecting a change in the pilots' perceptions of handling qualities, rather than changes in the aircraft model itself. The results indicate a need for tailoring the motion washout dynamics to suit the task. Visual-delay data are inconclusive but suggest that it may be better to allow some time delay in the visual path to minimize the mismatch between visual and motion, rather than eliminate the visual delay entirely through lead compensation.

  14. [Surgical solution to vitreous floaters visual problem].

    PubMed

    Martínez-Sanz, F; Velarde, J I; Casuso, P; Fernández-Cotero, J N

    2009-05-01

    To evaluate the role of 25 gauge pars-plana vitrectomy (25G-PPV), after a careful patient selection, when we find highly annoying vitreous floaters and to question if this is an ethical therapeutic option. A retrospective study of eight eyes (seven patients) aged 58+/-14 years old (range 42-78) high myopes and pseudophakes who underwent 25G-PPV. Clinical data and visual acuity were studied at six to twelve months follow-up. Health-related functioning and quality of life was measured with the 39-item National Eye Institute Visual Functioning Questionnaire (NEI VFQ-39). No complications were observed. All patients were satisfied. Safety at third month was 100% and 37.5% improved one or more lines of visual acuity. Vitreous floaters can be often undervaluated by ophthalmologists, resulting in no intervention. Conventional 20 gauge PPV after a carefully examination can be an effective option for some authors. 25G-PPV incorporates also advantages as the early recovery, with little complications in pseudophakic eyes.

  15. imDEV: a graphical user interface to R multivariate analysis tools in Microsoft Excel

    PubMed Central

    Grapov, Dmitry; Newman, John W.

    2012-01-01

    Summary: Interactive modules for Data Exploration and Visualization (imDEV) is a Microsoft Excel spreadsheet embedded application providing an integrated environment for the analysis of omics data through a user-friendly interface. Individual modules enables interactive and dynamic analyses of large data by interfacing R's multivariate statistics and highly customizable visualizations with the spreadsheet environment, aiding robust inferences and generating information-rich data visualizations. This tool provides access to multiple comparisons with false discovery correction, hierarchical clustering, principal and independent component analyses, partial least squares regression and discriminant analysis, through an intuitive interface for creating high-quality two- and a three-dimensional visualizations including scatter plot matrices, distribution plots, dendrograms, heat maps, biplots, trellis biplots and correlation networks. Availability and implementation: Freely available for download at http://sourceforge.net/projects/imdev/. Implemented in R and VBA and supported by Microsoft Excel (2003, 2007 and 2010). Contact: John.Newman@ars.usda.gov Supplementary Information: Installation instructions, tutorials and users manual are available at http://sourceforge.net/projects/imdev/. PMID:22815358

  16. Effectiveness of the use of question-driven levels of inquiry based instruction (QD-LOIBI) assisted visual multimedia supported teaching material on enhancing scientific explanation ability senior high school students

    NASA Astrophysics Data System (ADS)

    Suhandi, A.; Muslim; Samsudin, A.; Hermita, N.; Supriyatman

    2018-05-01

    In this study, the effectiveness of the use of Question-Driven Levels of Inquiry Based Instruction (QD-LOIBI) assisted visual multimedia supported teaching materials on enhancing senior high school students scientific explanation ability has been studied. QD-LOIBI was designed by following five-levels of inquiry proposed by Wenning. Visual multimedia used in teaching materials included image (photo), virtual simulation and video phenomena. QD-LOIBI assisted teaching materials supported by visual multimedia were tried out on senior high school students at one high school in one district in West Java. A quasi-experiment method with design one experiment group (n = 31) and one control group (n = 32) were used. Experimental group were given QD-LOIBI assisted teaching material supported by visual multimedia, whereas the control group were given QD-LOIBI assisted teaching materials not supported visual multimedia. Data on the ability of scientific explanation in both groups were collected by scientific explanation ability test in essay form concerning kinetic gas theory concept. The results showed that the number of students in the experimental class that has increased the category and quality of scientific explanation is greater than in the control class. These results indicate that the use of multimedia supported instructional materials developed for implementation of QD-LOIBI can improve students’ ability to provide explanations supported by scientific evidence gained from practicum activities and applicable concepts, laws, principles or theories.

  17. Reliable cues and signals of fruit quality are contingent on the habitat in black elder (Sambucus nigra).

    PubMed

    Schaefer, H Martin; Braun, Julius

    2009-06-01

    Communication mediates interactions between organisms and can be based on signals or cues. Signals are selected for their signaling function, whereas cues evolve for reasons other than signaling. To be evolutionarily stable, communication needs to be reliable on average, but the mechanisms that enforce reliability are hotly debated in light of strong environmental influence on signals and cues. While fruit quality in black elder (Sambucus nigra) is unrelated to fruit color, it is indicated by alternative pedicel phenotypes. Information on fruit quality has thus been transferred from the fruit to the developmentally associated pedicels, which are environmentally determined cues. Within each phenotype, color variation indicates fruit quality. Communication by black elder is thus reliable, but the proximate mechanisms enforcing reliability are habitat specific. High irradiance increases both the contrasts of the visual cue and fruit quality in the anthocyanin-based red pedicel phenotype, while shaded plants of the chlorophyll-based green phenotype apparently use signals by forgoing photosynthesis. This is because lower chlorophyll content in green pedicels creates contrasting pedicels, and higher contrasts indicate higher sugar content in the fruits of green pedicels. Because anthocyanins are light-induced, plants use cues when exposed to high irradiance, whereas they apparently use costly signals in the shade by reducing chlorophyll content in the pedicels. In behavioral field and laboratory experiments we document that avian seed dispersers select among pedicel phenotypes that indicate different fruit quality. Plants can thus increase their reproductive success by sending highly informative cues. Our results indicate how reliable information transfer can be maintained both in cues and signals in spite of substantial environmental influence on visual traits.

  18. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    PubMed

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  19. CLINICAL AUDIT OF IMAGE QUALITY IN RADIOLOGY USING VISUAL GRADING CHARACTERISTICS ANALYSIS.

    PubMed

    Tesselaar, Erik; Dahlström, Nils; Sandborg, Michael

    2016-06-01

    The aim of this work was to assess whether an audit of clinical image quality could be efficiently implemented within a limited time frame using visual grading characteristics (VGC) analysis. Lumbar spine radiography, bedside chest radiography and abdominal CT were selected. For each examination, images were acquired or reconstructed in two ways. Twenty images per examination were assessed by 40 radiology residents using visual grading of image criteria. The results were analysed using VGC. Inter-observer reliability was assessed. The results of the visual grading analysis were consistent with expected outcomes. The inter-observer reliability was moderate to good and correlated with perceived image quality (r(2) = 0.47). The median observation time per image or image series was within 2 min. These results suggest that the use of visual grading of image criteria to assess the quality of radiographs provides a rapid method for performing an image quality audit in a clinical environment. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Lip-reading aids word recognition most in moderate noise: a Bayesian explanation using high-dimensional feature space.

    PubMed

    Ma, Wei Ji; Zhou, Xiang; Ross, Lars A; Foxe, John J; Parra, Lucas C

    2009-01-01

    Watching a speaker's facial movements can dramatically enhance our ability to comprehend words, especially in noisy environments. From a general doctrine of combining information from different sensory modalities (the principle of inverse effectiveness), one would expect that the visual signals would be most effective at the highest levels of auditory noise. In contrast, we find, in accord with a recent paper, that visual information improves performance more at intermediate levels of auditory noise than at the highest levels, and we show that a novel visual stimulus containing only temporal information does the same. We present a Bayesian model of optimal cue integration that can explain these conflicts. In this model, words are regarded as points in a multidimensional space and word recognition is a probabilistic inference process. When the dimensionality of the feature space is low, the Bayesian model predicts inverse effectiveness; when the dimensionality is high, the enhancement is maximal at intermediate auditory noise levels. When the auditory and visual stimuli differ slightly in high noise, the model makes a counterintuitive prediction: as sound quality increases, the proportion of reported words corresponding to the visual stimulus should first increase and then decrease. We confirm this prediction in a behavioral experiment. We conclude that auditory-visual speech perception obeys the same notion of optimality previously observed only for simple multisensory stimuli.

  1. Perceptual visual dysfunction, physical impairment and quality of life in Bangladeshi children with cerebral palsy.

    PubMed

    Mitry, D; Williams, C; Northstone, K; Akter, A; Jewel, J; Khan, N; Muhit, M; Gilbert, C E; Bowman, R

    2016-09-01

    Cerebral palsy (CP) is the most common cause of motor disability in children and is often accompanied by sensory and/or cognitive impairment. The aim of this study was to characterise visual acuity impairment, perceptual visual dysfunction (PVD) and physical disability in a community-based sample of Bangladeshi children with CP and to assess the impact of these factors on the quality of life of the children. A key informant study was used to recruit children with CP from Sirajganj district. Gross Motor Function Classification System (GMFCS) levels and visual impairment were assessed by a physiotherapist and an optometrist, respectively. Assessments of visual perception were performed and standardised questionnaires were administered to each child's main carer to elicit indicators of PVD and parent-reported health-related quality of life. A generalised linear regression analysis was conducted to assess the determinants of the quality of life scores. 180 children were recruited. The median age was 8 years (IQR: 6-11 years); 112 (62%) were male; 57 (32%) had visual acuity impairment and 95 (53%) had some parent-reported PVD. In analyses adjusted for age, sex, GMFCS and acuity impairment, visual attention (p<0.001) and recognition/navigation (p<0.001) were associated with total health-related quality of life, and there were similar trends for total PVD score (p=0.006) and visual search (p=0.020). PVD is an important contributor in reducing quality of life in children with CP, independent of motor disability and acuity impairment. Better characterisation of PVD is important to help design interventions for affected children, which may improve their quality of life. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. miRNet - dissecting miRNA-target interactions and functional associations through network-based visual analysis

    PubMed Central

    Fan, Yannan; Siklenka, Keith; Arora, Simran K.; Ribeiro, Paula; Kimmins, Sarah; Xia, Jianguo

    2016-01-01

    MicroRNAs (miRNAs) can regulate nearly all biological processes and their dysregulation is implicated in various complex diseases and pathological conditions. Recent years have seen a growing number of functional studies of miRNAs using high-throughput experimental technologies, which have produced a large amount of high-quality data regarding miRNA target genes and their interactions with small molecules, long non-coding RNAs, epigenetic modifiers, disease associations, etc. These rich sets of information have enabled the creation of comprehensive networks linking miRNAs with various biologically important entities to shed light on their collective functions and regulatory mechanisms. Here, we introduce miRNet, an easy-to-use web-based tool that offers statistical, visual and network-based approaches to help researchers understand miRNAs functions and regulatory mechanisms. The key features of miRNet include: (i) a comprehensive knowledge base integrating high-quality miRNA-target interaction data from 11 databases; (ii) support for differential expression analysis of data from microarray, RNA-seq and quantitative PCR; (iii) implementation of a flexible interface for data filtering, refinement and customization during network creation; (iv) a powerful fully featured network visualization system coupled with enrichment analysis. miRNet offers a comprehensive tool suite to enable statistical analysis and functional interpretation of various data generated from current miRNA studies. miRNet is freely available at http://www.mirnet.ca. PMID:27105848

  3. Influence of Personal Factors on Sound Perception and Overall Experience in Urban Green Areas. A Case Study of a Cycling Path Highly Exposed to Road Traffic Noise.

    PubMed

    Aletta, Francesco; Van Renterghem, Timothy; Botteldooren, Dick

    2018-05-30

    In contemporary urban design, green public areas play a vital role. They have great societal value, but if exposed to undue environmental noise their restorative potential might be compromised. On the other hand, research has shown that the presence of greenery can moderate noise annoyance in areas with high sound levels, while personal factors are expected to play an important role too. A cycling path bordered by vegetation, but highly exposed to road traffic noise, was here considered as a case study. A sound perception survey was submitted to participants on site and they were subsequently sorted into groups according to their noise sensitivity, visual attention and attitude towards greenery. The aim of this study was testing whether these three personal factors could affect their noise perception and overall experience of the place. Results showed that people highly sensitive to noise and more sceptical towards greenery's potential as an environmental moderator reported worse soundscape quality, while visually attentive people reported better quality. These three personal factors were found to be statistically independent. This study shows that several person-related factors impact the assessment of the sound environment in green areas. Although the majority of the respondents benefit from the presence of visual green, policy-makers and planners should be aware that for a significant subset of the population, it should be accompanied by a tranquil soundscape to be fully appreciated.

  4. Hemispheric asymmetry of liking for representational and abstract paintings.

    PubMed

    Nadal, Marcos; Schiavi, Susanna; Cattaneo, Zaira

    2017-10-13

    Although the neural correlates of the appreciation of aesthetic qualities have been the target of much research in the past decade, few experiments have explored the hemispheric asymmetries in underlying processes. In this study, we used a divided visual field paradigm to test for hemispheric asymmetries in men and women's preference for abstract and representational artworks. Both male and female participants liked representational paintings more when presented in the right visual field, whereas preference for abstract paintings was unaffected by presentation hemifield. We hypothesize that this result reflects a facilitation of the sort of visual processes relevant to laypeople's liking for art-specifically, local processing of highly informative object features-when artworks are presented in the right visual field, given the left hemisphere's advantage in processing such features.

  5. Visualizing Article Similarities via Sparsified Article Network and Map Projection for Systematic Reviews.

    PubMed

    Ji, Xiaonan; Machiraju, Raghu; Ritter, Alan; Yen, Po-Yin

    2017-01-01

    Systematic Reviews (SRs) of biomedical literature summarize evidence from high-quality studies to inform clinical decisions, but are time and labor intensive due to the large number of article collections. Article similarities established from textual features have been shown to assist in the identification of relevant articles, thus facilitating the article screening process efficiently. In this study, we visualized article similarities to extend its utilization in practical settings for SR researchers, aiming to promote human comprehension of article distributions and hidden patterns. To prompt an effective visualization in an interpretable, intuitive, and scalable way, we implemented a graph-based network visualization with three network sparsification approaches and a distance-based map projection via dimensionality reduction. We evaluated and compared three network sparsification approaches and the visualization types (article network vs. article map). We demonstrated the effectiveness in revealing article distribution and exhibiting clustering patterns of relevant articles with practical meanings for SRs.

  6. TRAPR: R Package for Statistical Analysis and Visualization of RNA-Seq Data.

    PubMed

    Lim, Jae Hyun; Lee, Soo Youn; Kim, Ju Han

    2017-03-01

    High-throughput transcriptome sequencing, also known as RNA sequencing (RNA-Seq), is a standard technology for measuring gene expression with unprecedented accuracy. Numerous bioconductor packages have been developed for the statistical analysis of RNA-Seq data. However, these tools focus on specific aspects of the data analysis pipeline, and are difficult to appropriately integrate with one another due to their disparate data structures and processing methods. They also lack visualization methods to confirm the integrity of the data and the process. In this paper, we propose an R-based RNA-Seq analysis pipeline called TRAPR, an integrated tool that facilitates the statistical analysis and visualization of RNA-Seq expression data. TRAPR provides various functions for data management, the filtering of low-quality data, normalization, transformation, statistical analysis, data visualization, and result visualization that allow researchers to build customized analysis pipelines.

  7. Using a Teaching Intervention and Calibrated Peer Review™ Diagnostics to Improve Visual Communication Skills.

    PubMed

    Saterbak, Ann; Moturu, Anoosha; Volz, Tracy

    2018-03-01

    Rice University's bioengineering department incorporates written, oral, and visual communication instruction into its undergraduate curriculum to aid student learning and to prepare students to communicate their knowledge and discoveries precisely and persuasively. In a tissue culture lab course, we used a self- and peer-review tool called Calibrated Peer Review™ (CPR) to diagnose student learning gaps in visual communication skills on a poster assignment. We then designed an active learning intervention that required students to practice the visual communication skills that needed improvement and used CPR to measure the changes. After the intervention, we observed that students performed significantly better in their ability to develop high quality graphs and tables that represent experimental data. Based on these outcomes, we conclude that guided task practice, collaborative learning, and calibrated peer review can be used to improve engineering students' visual communication skills.

  8. Using Saliency-Weighted Disparity Statistics for Objective Visual Comfort Assessment of Stereoscopic Images

    NASA Astrophysics Data System (ADS)

    Zhang, Wenlan; Luo, Ting; Jiang, Gangyi; Jiang, Qiuping; Ying, Hongwei; Lu, Jing

    2016-06-01

    Visual comfort assessment (VCA) for stereoscopic images is a particularly significant yet challenging task in 3D quality of experience research field. Although the subjective assessment given by human observers is known as the most reliable way to evaluate the experienced visual discomfort, it is time-consuming and non-systematic. Therefore, it is of great importance to develop objective VCA approaches that can faithfully predict the degree of visual discomfort as human beings do. In this paper, a novel two-stage objective VCA framework is proposed. The main contribution of this study is that the important visual attention mechanism of human visual system is incorporated for visual comfort-aware feature extraction. Specifically, in the first stage, we first construct an adaptive 3D visual saliency detection model to derive saliency map of a stereoscopic image, and then a set of saliency-weighted disparity statistics are computed and combined to form a single feature vector to represent a stereoscopic image in terms of visual comfort. In the second stage, a high dimensional feature vector is fused into a single visual comfort score by performing random forest algorithm. Experimental results on two benchmark databases confirm the superior performance of the proposed approach.

  9. A Visual Analytics Approach for Station-Based Air Quality Data

    PubMed Central

    Du, Yi; Ma, Cuixia; Wu, Chao; Xu, Xiaowei; Guo, Yike; Zhou, Yuanchun; Li, Jianhui

    2016-01-01

    With the deployment of multi-modality and large-scale sensor networks for monitoring air quality, we are now able to collect large and multi-dimensional spatio-temporal datasets. For these sensed data, we present a comprehensive visual analysis approach for air quality analysis. This approach integrates several visual methods, such as map-based views, calendar views, and trends views, to assist the analysis. Among those visual methods, map-based visual methods are used to display the locations of interest, and the calendar and the trends views are used to discover the linear and periodical patterns. The system also provides various interaction tools to combine the map-based visualization, trends view, calendar view and multi-dimensional view. In addition, we propose a self-adaptive calendar-based controller that can flexibly adapt the changes of data size and granularity in trends view. Such a visual analytics system would facilitate big-data analysis in real applications, especially for decision making support. PMID:28029117

  10. A Visual Analytics Approach for Station-Based Air Quality Data.

    PubMed

    Du, Yi; Ma, Cuixia; Wu, Chao; Xu, Xiaowei; Guo, Yike; Zhou, Yuanchun; Li, Jianhui

    2016-12-24

    With the deployment of multi-modality and large-scale sensor networks for monitoring air quality, we are now able to collect large and multi-dimensional spatio-temporal datasets. For these sensed data, we present a comprehensive visual analysis approach for air quality analysis. This approach integrates several visual methods, such as map-based views, calendar views, and trends views, to assist the analysis. Among those visual methods, map-based visual methods are used to display the locations of interest, and the calendar and the trends views are used to discover the linear and periodical patterns. The system also provides various interaction tools to combine the map-based visualization, trends view, calendar view and multi-dimensional view. In addition, we propose a self-adaptive calendar-based controller that can flexibly adapt the changes of data size and granularity in trends view. Such a visual analytics system would facilitate big-data analysis in real applications, especially for decision making support.

  11. Linking microarray reporters with protein functions

    PubMed Central

    Gaj, Stan; van Erk, Arie; van Haaften, Rachel IM; Evelo, Chris TA

    2007-01-01

    Background The analysis of microarray experiments requires accurate and up-to-date functional annotation of the microarray reporters to optimize the interpretation of the biological processes involved. Pathway visualization tools are used to connect gene expression data with existing biological pathways by using specific database identifiers that link reporters with elements in the pathways. Results This paper proposes a novel method that aims to improve microarray reporter annotation by BLASTing the original reporter sequences against a species-specific EMBL subset, that was derived from and crosslinked back to the highly curated UniProt database. The resulting alignments were filtered using high quality alignment criteria and further compared with the outcome of a more traditional approach, where reporter sequences were BLASTed against EnsEMBL followed by locating the corresponding protein (UniProt) entry for the high quality hits. Combining the results of both methods resulted in successful annotation of > 58% of all reporter sequences with UniProt IDs on two commercial array platforms, increasing the amount of Incyte reporters that could be coupled to Gene Ontology terms from 32.7% to 58.3% and to a local GenMAPP pathway from 9.6% to 16.7%. For Agilent, 35.3% of the total reporters are now linked towards GO nodes and 7.1% on local pathways. Conclusion Our methods increased the annotation quality of microarray reporter sequences and allowed us to visualize more reporters using pathway visualization tools. Even in cases where the original reporter annotation showed the correct description the new identifiers often allowed improved pathway and Gene Ontology linking. These methods are freely available at http://www.bigcat.unimaas.nl/public/publications/Gaj_Annotation/. PMID:17897448

  12. Evaluation of the visual performance of image processing pipes: information value of subjective image attributes

    NASA Astrophysics Data System (ADS)

    Nyman, G.; Häkkinen, J.; Koivisto, E.-M.; Leisti, T.; Lindroos, P.; Orenius, O.; Virtanen, T.; Vuori, T.

    2010-01-01

    Subjective image quality data for 9 image processing pipes and 8 image contents (taken with mobile phone camera, 72 natural scene test images altogether) from 14 test subjects were collected. A triplet comparison setup and a hybrid qualitative/quantitative methodology were applied. MOS data and spontaneous, subjective image quality attributes to each test image were recorded. The use of positive and negative image quality attributes by the experimental subjects suggested a significant difference between the subjective spaces of low and high image quality. The robustness of the attribute data was shown by correlating DMOS data of the test images against their corresponding, average subjective attribute vector length data. The findings demonstrate the information value of spontaneous, subjective image quality attributes in evaluating image quality at variable quality levels. We discuss the implications of these findings for the development of sensitive performance measures and methods in profiling image processing systems and their components, especially at high image quality levels.

  13. Aesthetics by Numbers: Links between Perceived Texture Qualities and Computed Visual Texture Properties

    PubMed Central

    Jacobs, Richard H. A. H.; Haak, Koen V.; Thumfart, Stefan; Renken, Remco; Henson, Brian; Cornelissen, Frans W.

    2016-01-01

    Our world is filled with texture. For the human visual system, this is an important source of information for assessing environmental and material properties. Indeed—and presumably for this reason—the human visual system has regions dedicated to processing textures. Despite their abundance and apparent relevance, only recently the relationships between texture features and high-level judgments have captured the interest of mainstream science, despite long-standing indications for such relationships. In this study, we explore such relationships, as these might be used to predict perceived texture qualities. This is relevant, not only from a psychological/neuroscience perspective, but also for more applied fields such as design, architecture, and the visual arts. In two separate experiments, observers judged various qualities of visual textures such as beauty, roughness, naturalness, elegance, and complexity. Based on factor analysis, we find that in both experiments, ~75% of the variability in the judgments could be explained by a two-dimensional space, with axes that are closely aligned to the beauty and roughness judgments. That a two-dimensional judgment space suffices to capture most of the variability in the perceived texture qualities suggests that observers use a relatively limited set of internal scales on which to base various judgments, including aesthetic ones. Finally, for both of these judgments, we determined the relationship with a large number of texture features computed for each of the texture stimuli. We find that the presence of lower spatial frequencies, oblique orientations, higher intensity variation, higher saturation, and redness correlates with higher beauty ratings. Features that captured image intensity and uniformity correlated with roughness ratings. Therefore, a number of computational texture features are predictive of these judgments. This suggests that perceived texture qualities—including the aesthetic appreciation—are sufficiently universal to be predicted—with reasonable accuracy—based on the computed feature content of the textures. PMID:27493628

  14. An Ecological Alternative to Snodgrass & Vanderwart: 360 High Quality Colour Images with Norms for Seven Psycholinguistic Variables

    PubMed Central

    Moreno-Martínez, Francisco Javier; Montoro, Pedro R.

    2012-01-01

    This work presents a new set of 360 high quality colour images belonging to 23 semantic subcategories. Two hundred and thirty-six Spanish speakers named the items and also provided data from seven relevant psycholinguistic variables: age of acquisition, familiarity, manipulability, name agreement, typicality and visual complexity. Furthermore, we also present lexical frequency data derived from Internet search hits. Apart from the high number of variables evaluated, knowing that it affects the processing of stimuli, this new set presents important advantages over other similar image corpi: (a) this corpus presents a broad number of subcategories and images; for example, this will permit researchers to select stimuli of appropriate difficulty as required, (e.g., to deal with problems derived from ceiling effects); (b) the fact of using coloured stimuli provides a more realistic, ecologically-valid, representation of real life objects. In sum, this set of stimuli provides a useful tool for research on visual object-and word- processing, both in neurological patients and in healthy controls. PMID:22662166

  15. A framework for visual communication at Nature.

    PubMed

    Krause, Kelly

    2016-04-25

    The scientific journal Nature, published weekly since 1869, serves as an excellent case study in visual communication. While journals are becoming increasingly specialist, Nature remains firmly multidisciplinary; and unlike many scientific journals, it contains original journalism, opinion pieces, and expert analysis in addition to peer-reviewed research papers. This variety of content types-covering an extensive range of scientific disciplines-translates into a wide and varied audience, and the need to employ an equally wide variety of communication styles.For example, a research paper may employ technical language to communicate to a highly specialized audience in that field, whereas a news story on the same subject will explain the science to an educated lay audience, often adding a wider context and stripping out acronyms. Each type of piece will use a communication approach tailored for its intended audience.This is true for visual content as well: the intended audience of a scientific figure, illustration or data visualization will determine the design approach to that visual. At Nature, given the high volume of content plus high quality standards, this process is applied in a fairly systematic way, using a framework to guide creative decision-making. That framework is described here, along with a discussion of best practices for the design of research figures and graphics by context. © The Author(s) 2016.

  16. Visual disability and quality of life in glaucoma patients.

    PubMed

    Cesareo, Massimo; Ciuffoletti, Elena; Ricci, Federico; Missiroli, Filippo; Giuliano, Mario Alberto; Mancino, Raffaele; Nucci, Carlo

    2015-01-01

    Glaucoma is an optic neuropathy that can result in progressive and irreversible vision loss, thereby affecting quality of life (QoL) of patients. Several studies have shown a strong correlation between visual field damage and visual disability in patients with glaucoma, even in the early stages of the disease. Visual impairment due to glaucoma affects normal daily activities required for independent living, such as driving, walking, and reading. There is no generally accepted instrument for assessing quality of life in glaucoma patients; different factors involved in visual disability from the disease are difficult to quantify and not easily standardized. This chapter summarizes recent works from clinical and epidemiological studies, which describe how glaucoma affects the performance of important vision-related activities and QoL. © 2015 Elsevier B.V. All rights reserved.

  17. Evolution of mammographic image quality in the state of Rio de Janeiro*

    PubMed Central

    Villar, Vanessa Cristina Felippe Lopes; Seta, Marismary Horsth De; de Andrade, Carla Lourenço Tavares; Delamarque, Elizabete Vianna; de Azevedo, Ana Cecília Pedrosa

    2015-01-01

    Objective To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. Materials and Methods Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval. Results Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%). Conclusion The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval. PMID:25987749

  18. Fluorescence-based visualization of autophagic activity predicts mouse embryo viability

    NASA Astrophysics Data System (ADS)

    Tsukamoto, Satoshi; Hara, Taichi; Yamamoto, Atsushi; Kito, Seiji; Minami, Naojiro; Kubota, Toshiro; Sato, Ken; Kokubo, Toshiaki

    2014-03-01

    Embryo quality is a critical parameter in assisted reproductive technologies. Although embryo quality can be evaluated morphologically, embryo morphology does not correlate perfectly with embryo viability. To improve this, it is important to understand which molecular mechanisms are involved in embryo quality control. Autophagy is an evolutionarily conserved catabolic process in which cytoplasmic materials sequestered by autophagosomes are degraded in lysosomes. We previously demonstrated that autophagy is highly activated after fertilization and is essential for further embryonic development. Here, we developed a simple fluorescence-based method for visualizing autophagic activity in live mouse embryos. Our method is based on imaging of the fluorescence intensity of GFP-LC3, a versatile marker for autophagy, which is microinjected into the embryos. Using this method, we show that embryonic autophagic activity declines with advancing maternal age, probably due to a decline in the activity of lysosomal hydrolases. We also demonstrate that embryonic autophagic activity is associated with the developmental viability of the embryo. Our results suggest that embryonic autophagic activity can be utilized as a novel indicator of embryo quality.

  19. Scater: pre-processing, quality control, normalization and visualization of single-cell RNA-seq data in R.

    PubMed

    McCarthy, Davis J; Campbell, Kieran R; Lun, Aaron T L; Wills, Quin F

    2017-04-15

    Single-cell RNA sequencing (scRNA-seq) is increasingly used to study gene expression at the level of individual cells. However, preparing raw sequence data for further analysis is not a straightforward process. Biases, artifacts and other sources of unwanted variation are present in the data, requiring substantial time and effort to be spent on pre-processing, quality control (QC) and normalization. We have developed the R/Bioconductor package scater to facilitate rigorous pre-processing, quality control, normalization and visualization of scRNA-seq data. The package provides a convenient, flexible workflow to process raw sequencing reads into a high-quality expression dataset ready for downstream analysis. scater provides a rich suite of plotting tools for single-cell data and a flexible data structure that is compatible with existing tools and can be used as infrastructure for future software development. The open-source code, along with installation instructions, vignettes and case studies, is available through Bioconductor at http://bioconductor.org/packages/scater . davis@ebi.ac.uk. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press.

  20. Visual land-use compatibility and scenic-resource quality

    Treesearch

    William G. Hendrix

    1977-01-01

    The effect that land-use relationships have upon perceived quality of the visual landscape is discussed, and a case is made for expansion of fit-misfit theory into what has been called visual land-use compatibility. An assessment methodology that was designed to test people's perceptions of land-use relationships is presented and the results are discussed.

  1. Physical Activity, Body Composition, and Perceived Quality of Life of Adults with Visual Impairments

    ERIC Educational Resources Information Center

    Holbrook, Elizabeth A.; Caputo, Jennifer L.; Perry, Tara L.; Fuller, Dana K.; Morgan, Don W.

    2009-01-01

    Relatively little is known about the health and fitness of adults with visual impairments. This article documents the physical activity levels and body-composition profiles of young and middle-aged adults with visual impairments and addresses the concomitant effects of these factors on perceived quality of life. (Contains 2 tables.)

  2. Methodology for cork plank characterization (Quercus suber L.) by near-infrared spectroscopy and image analysis

    NASA Astrophysics Data System (ADS)

    Prades, Cristina; García-Olmo, Juan; Romero-Prieto, Tomás; García de Ceca, José L.; López-Luque, Rafael

    2010-06-01

    The procedures used today to characterize cork plank for the manufacture of cork bottle stoppers continue to be based on a traditional, manual method that is highly subjective. Furthermore, there is no specific legislation regarding cork classification. The objective of this viability study is to assess the potential of near-infrared spectroscopy (NIRS) technology for characterizing cork plank according to the following variables: aspect or visual quality, porosity, moisture and geographical origin. In order to calculate the porosity coefficient, an image analysis program was specifically developed in Visual Basic language for a desktop scanner. A set comprising 170 samples from two geographical areas of Andalusia (Spain) was classified into eight quality classes by visual inspection. Spectra were obtained in the transverse and tangential sections of the cork planks using an NIRSystems 6500 SY II reflectance spectrophotometer. The quantitative calibrations showed cross-validation coefficients of determination of 0.47 for visual quality, 0.69 for porosity and 0.66 for moisture. The results obtained using NIRS technology are promising considering the heterogeneity and variability of a natural product such as cork in spite of the fact that the standard error of cross validation (SECV) in the quantitative analysis is greater than the standard error of laboratory (SEL) for the three variables. The qualitative analysis regarding geographical origin achieved very satisfactory results. Applying these methods in industry will permit quality control procedures to be automated, as well as establishing correlations between the different classification systems currently used in the sector. These methods can be implemented in the cork chain of custody certification and will also provide a certainly more objective tool for assessing the economic value of the product.

  3. We Don't Say "H" Here

    ERIC Educational Resources Information Center

    Scott Dunda, Jessica Mae

    2017-01-01

    This article is focused on building interdependence among diverse learners through four specific engagements in the art room: Friend/Family Involvement, Team-Building, Leadership Habits, and Service Learning. These strategies have been beneficial to the author in creating a sustainable model for high-quality visual arts instruction.

  4. D-peaks: a visual tool to display ChIP-seq peaks along the genome.

    PubMed

    Brohée, Sylvain; Bontempi, Gianluca

    2012-01-01

    ChIP-sequencing is a method of choice to localize the positions of protein binding sites on DNA on a whole genomic scale. The deciphering of the sequencing data produced by this novel technique is challenging and it is achieved by their rigorous interpretation using dedicated tools and adapted visualization programs. Here, we present a bioinformatics tool (D-peaks) that adds several possibilities (including, user-friendliness, high-quality, relative position with respect to the genomic features) to the well-known visualization browsers or databases already existing. D-peaks is directly available through its web interface http://rsat.ulb.ac.be/dpeaks/ as well as a command line tool.

  5. Workshop on Molecular Animation

    PubMed Central

    Bromberg, Sarina; Chiu, Wah; Ferrin, Thomas E.

    2011-01-01

    Summary February 25–26, 2010, in San Francisco, the Resource for Biocomputing, Visualization and Informatics (RBVI) and the National Center for Macromolecular Imaging (NCMI) hosted a molecular animation workshop for 21 structural biologists, molecular animators, and creators of molecular visualization software. Molecular animation aims to visualize scientific understanding of biomolecular processes and structures. The primary goal of the workshop was to identify the necessary tools for: producing high quality molecular animations, understanding complex molecular and cellular structures, creating publication supplementary materials and conference presentations, and teaching science to students and the public. Another use of molecular animation emerged in the workshop: helping to focus scientific inquiry about the motions of molecules and enhancing informal communication within and between laboratories. PMID:20947014

  6. Optimal spatiotemporal representation of multichannel EEG for recognition of brain states associated with distinct visual stimulus

    NASA Astrophysics Data System (ADS)

    Hramov, Alexander; Musatov, Vyacheslav Yu.; Runnova, Anastasija E.; Efremova, Tatiana Yu.; Koronovskii, Alexey A.; Pisarchik, Alexander N.

    2018-04-01

    In the paper we propose an approach based on artificial neural networks for recognition of different human brain states associated with distinct visual stimulus. Based on the developed numerical technique and the analysis of obtained experimental multichannel EEG data, we optimize the spatiotemporal representation of multichannel EEG to provide close to 97% accuracy in recognition of the EEG brain states during visual perception. Different interpretations of an ambiguous image produce different oscillatory patterns in the human EEG with similar features for every interpretation. Since these features are inherent to all subjects, a single artificial network can classify with high quality the associated brain states of other subjects.

  7. Visual impairment, visual functioning, and quality of life assessments in patients with glaucoma.

    PubMed Central

    Parrish, R K

    1996-01-01

    BACKGROUND/PURPOSE: To determine the relation between visual impairment, visual functioning, and the global quality of life in patients with glaucoma. METHODS: Visual impairment, defined with the American Medical Association Guides to the Evaluation of Permanent Impairment; visual functioning, measured with the VF-14 and the Field Test Version of the National Eye Institute-Visual Functioning Questionnaire (NEI-VFQ); and the global quality of life, assessed with the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36), were determined in 147 consecutive patients with glaucoma. RESULTS: None of the SF-36 domains demonstrated more than a weak correlation with visual impairment. The VF-14 scores were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual field impairment; vision specific social functioning, near activities, vision specific role difficulties, general vision, vision specific mental health, color vision, and driving were modestly correlated; visual pain was weakly correlated; and two were not significantly correlated. Correcting for visual actuity weakened the strength of the correlation coefficients. CONCLUSIONS: The SF-36 is unlikely to be useful in determining visual impairment in patients with glaucoma. Based on the moderate correlation between visual field impairment and the VF-14 score, this questionnaire may be generalizable to patients with glaucoma. Several of the NEI-VFQ scales correlate with visual field impairment scores in patients with a wide range of glaucomatous damage. PMID:8981717

  8. Quality-Related Monitoring and Grading of Granulated Products by Weibull-Distribution Modeling of Visual Images with Semi-Supervised Learning

    PubMed Central

    Liu, Jinping; Tang, Zhaohui; Xu, Pengfei; Liu, Wenzhong; Zhang, Jin; Zhu, Jianyong

    2016-01-01

    The topic of online product quality inspection (OPQI) with smart visual sensors is attracting increasing interest in both the academic and industrial communities on account of the natural connection between the visual appearance of products with their underlying qualities. Visual images captured from granulated products (GPs), e.g., cereal products, fabric textiles, are comprised of a large number of independent particles or stochastically stacking locally homogeneous fragments, whose analysis and understanding remains challenging. A method of image statistical modeling-based OPQI for GP quality grading and monitoring by a Weibull distribution(WD) model with a semi-supervised learning classifier is presented. WD-model parameters (WD-MPs) of GP images’ spatial structures, obtained with omnidirectional Gaussian derivative filtering (OGDF), which were demonstrated theoretically to obey a specific WD model of integral form, were extracted as the visual features. Then, a co-training-style semi-supervised classifier algorithm, named COSC-Boosting, was exploited for semi-supervised GP quality grading, by integrating two independent classifiers with complementary nature in the face of scarce labeled samples. Effectiveness of the proposed OPQI method was verified and compared in the field of automated rice quality grading with commonly-used methods and showed superior performance, which lays a foundation for the quality control of GP on assembly lines. PMID:27367703

  9. Evaluation of differences in quality of experience features for test stimuli of good-only and bad-only overall audiovisual quality

    NASA Astrophysics Data System (ADS)

    Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith

    2013-01-01

    Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.

  10. Conductor gestures influence evaluations of ensemble performance

    PubMed Central

    Morrison, Steven J.; Price, Harry E.; Smedley, Eric M.; Meals, Cory D.

    2014-01-01

    Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor’s gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance: articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and non-majors (N = 285) viewed sixteen 30 s performances and evaluated the quality of the ensemble’s articulation, dynamics, technique, and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble’s performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity. PMID:25104944

  11. [Quality of life - methodology and clinical practice aspects with a focus on ocular medicine].

    PubMed

    Franke, G H; Gall, C

    2008-08-01

    Due to the demographic development in western industrialised countries, the proportion of visually impaired persons is likely to increase in the future. Currently there is a shift in scientific recognition from relative neglect of psychopathological distress in the visually impaired to better notice of disease-related subjective impairments that are detectable with specific questionnaire measures. Visual acuity primarily determines the subjective rating of visual functioning independent from the eye disease. Ophthalmic patients who show only mild symptoms from a medical point of view normally suffer considerably diminished vision-related quality of life with respect to physical, functional, mental, and social aspects. Treatment effects have been shown using vision-related quality-of-life measures for different ophthalmic diseases, particularly cataract surgery. Assessment of vision-related quality of life provides a meaningful complement to objective data.

  12. An enhanced functional ability questionnaire (faVIQ) to measure the impact of rehabilitation services on the visually impaired

    PubMed Central

    Wolffsohn, James Stuart; Jackson, Jonathan; Hunt, Olivia Anne; Cottriall, Charles; Lindsay, Jennifer; Gilmour, Richard; Sinclair, Anne; Harper, Robert

    2014-01-01

    AIM To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. METHODS Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual impairment. RESULTS Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. CONCLUSION The faVIQ allows sensitive assessment of quality-of-life in the visually impaired and should support studies which evaluate the effectiveness of low vision rehabilitation services. PMID:24634868

  13. An enhanced functional ability questionnaire (faVIQ) to measure the impact of rehabilitation services on the visually impaired.

    PubMed

    Wolffsohn, James Stuart; Jackson, Jonathan; Hunt, Olivia Anne; Cottriall, Charles; Lindsay, Jennifer; Gilmour, Richard; Sinclair, Anne; Harper, Robert

    2014-01-01

    To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual impairment. Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. The faVIQ allows sensitive assessment of quality-of-life in the visually impaired and should support studies which evaluate the effectiveness of low vision rehabilitation services.

  14. Visual quality evaluation of urban commercial streetscape for the development of landscape visual planning system in provincial street corridors in Malang, Indonesia

    NASA Astrophysics Data System (ADS)

    Santosa, H.; Ernawati, J.; Wulandari, L. D.

    2018-03-01

    The visual aesthetic experience in urban spaces is important in establishing a comfortable and satisfying experience for the community. The embodiment of a good visual image of urban space will encourage the emergence of positive perceptions and meanings stimulating the community to produce a good reaction to its urban space. Moreover, to establish a Good Governance in urban planning and design, it is necessary to boost and promote a community participation in the process of controlling the visual quality of urban space through the visual quality evaluation on urban street corridors. This study is an early stage as part of the development of ‘Landscape Visual Planning System’ on the commercial street corridor in Malang. Accordingly, the research aims to evaluate the physical characteristics and the public preferences of the spatial and visual aspects in five provincial road corridors in Malang. This study employs a field survey methods, and an environmental aesthetics approach through semantic differential method. The result of the identification of physical characteristics and the assessment of public preferences on the spatial and visual aspects of the five provincial streets serve as the basis for constructing the 3d interactive simulation scenarios in the Landscape Visual Planning System.

  15. Effects of frequency shifts and visual gender information on vowel category judgments

    NASA Astrophysics Data System (ADS)

    Glidden, Catherine; Assmann, Peter F.

    2003-10-01

    Visual morphing techniques were used together with a high-quality vocoder to study the audiovisual contribution of talker gender to the identification of frequency-shifted vowels. A nine-step continuum ranging from ``bit'' to ``bet'' was constructed from natural recorded syllables spoken by an adult female talker. Upward and downward frequency shifts in spectral envelope (scale factors of 0.85 and 1.0) were applied in combination with shifts in fundamental frequency, F0 (scale factors of 0.5 and 1.0). Downward frequency shifts generally resulted in malelike voices whereas upward shifts were perceived as femalelike. Two separate nine-step visual continua from ``bit'' to ``bet'' were also constructed, one from a male face and the other a female face, each producing the end-point words. Each step along the two visual continua was paired with the corresponding step on the acoustic continuum, creating natural audiovisual utterances. Category boundary shifts were found for both acoustic cues (F0 and formant frequency shifts) and visual cues (visual gender). The visual gender effect was larger when acoustic and visual information were matched appropriately. These results suggest that visual information provided by the speech signal plays an important supplemental role in talker normalization.

  16. Real-time visual communication to aid disaster recovery in a multi-segment hybrid wireless networking system

    NASA Astrophysics Data System (ADS)

    Al Hadhrami, Tawfik; Wang, Qi; Grecos, Christos

    2012-06-01

    When natural disasters or other large-scale incidents occur, obtaining accurate and timely information on the developing situation is vital to effective disaster recovery operations. High-quality video streams and high-resolution images, if available in real time, would provide an invaluable source of current situation reports to the incident management team. Meanwhile, a disaster often causes significant damage to the communications infrastructure. Therefore, another essential requirement for disaster management is the ability to rapidly deploy a flexible incident area communication network. Such a network would facilitate the transmission of real-time video streams and still images from the disrupted area to remote command and control locations. In this paper, a comprehensive end-to-end video/image transmission system between an incident area and a remote control centre is proposed and implemented, and its performance is experimentally investigated. In this study a hybrid multi-segment communication network is designed that seamlessly integrates terrestrial wireless mesh networks (WMNs), distributed wireless visual sensor networks, an airborne platform with video camera balloons, and a Digital Video Broadcasting- Satellite (DVB-S) system. By carefully integrating all of these rapidly deployable, interworking and collaborative networking technologies, we can fully exploit the joint benefits provided by WMNs, WSNs, balloon camera networks and DVB-S for real-time video streaming and image delivery in emergency situations among the disaster hit area, the remote control centre and the rescue teams in the field. The whole proposed system is implemented in a proven simulator. Through extensive simulations, the real-time visual communication performance of this integrated system has been numerically evaluated, towards a more in-depth understanding in supporting high-quality visual communications in such a demanding context.

  17. A Visual Arts Education pedagogical approach for enhancing quality of life for persons with dementia (innovative practice).

    PubMed

    Tietyen, Ann C; Richards, Allan G

    2017-01-01

    A new and innovative pedagogical approach that administers hands-on visual arts activities to persons with dementia based on the field of Visual Arts Education is reported in this paper. The aims of this approach are to enhance cognition and improve quality of life. These aims were explored in a small qualitative study with eight individuals with moderate dementia, and the results are published as a thesis. In this paper, we summarize and report the results of this small qualitative study and expand upon the rationale for the Visual Arts Education pedagogical approach that has shown promise for enhancing cognitive processes and improving quality of life for persons with dementia.

  18. The effect of image quality, repeated study, and assessment method on anatomy learning.

    PubMed

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A; Wainman, Bruce C

    2017-06-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality images of the human hand and human eye. On day 0, participants learned about each anatomical specimen from paper booklets using either low-quality or high-quality images, and then completed a comprehension test using either 2D images or three-dimensional (3D) cadaveric specimens. On day 1, participants relearned each booklet, and on day 2 participants completed a final comprehension test using either 2D images or 3D cadaveric specimens. The effect of image quality on learning varied according to anatomical content, with high-quality images having a greater effect on improving learning of hand anatomy than eye anatomy (high-quality vs. low-quality for hand anatomy P = 0.018; high-quality vs. low-quality for eye anatomy P = 0.247). Also, the benefit of high-quality images on hand anatomy learning was restricted to performance on short-answer (SA) questions immediately after learning (high-quality vs. low-quality on SA questions P = 0.018), but did not apply to performance on multiple-choice (MC) questions (high-quality vs. low-quality on MC questions P = 0.109) or after participants had an additional learning opportunity (24 hours later) with anatomy content (high vs. low on SA questions P = 0.643). This study underscores the limited impact of image quality on anatomy learning, and questions whether investment in enhancing image quality of learning aids significantly promotes knowledge development. Anat Sci Educ 10: 249-261. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  19. Halftone visual cryptography.

    PubMed

    Zhou, Zhi; Arce, Gonzalo R; Di Crescenzo, Giovanni

    2006-08-01

    Visual cryptography encodes a secret binary image (SI) into n shares of random binary patterns. If the shares are xeroxed onto transparencies, the secret image can be visually decoded by superimposing a qualified subset of transparencies, but no secret information can be obtained from the superposition of a forbidden subset. The binary patterns of the n shares, however, have no visual meaning and hinder the objectives of visual cryptography. Extended visual cryptography [1] was proposed recently to construct meaningful binary images as shares using hypergraph colourings, but the visual quality is poor. In this paper, a novel technique named halftone visual cryptography is proposed to achieve visual cryptography via halftoning. Based on the blue-noise dithering principles, the proposed method utilizes the void and cluster algorithm [2] to encode a secret binary image into n halftone shares (images) carrying significant visual information. The simulation shows that the visual quality of the obtained halftone shares are observably better than that attained by any available visual cryptography method known to date.

  20. Dissociating neural variability related to stimulus quality and response times in perceptual decision-making.

    PubMed

    Bode, Stefan; Bennett, Daniel; Sewell, David K; Paton, Bryan; Egan, Gary F; Smith, Philip L; Murawski, Carsten

    2018-03-01

    According to sequential sampling models, perceptual decision-making is based on accumulation of noisy evidence towards a decision threshold. The speed with which a decision is reached is determined by both the quality of incoming sensory information and random trial-by-trial variability in the encoded stimulus representations. To investigate those decision dynamics at the neural level, participants made perceptual decisions while functional magnetic resonance imaging (fMRI) was conducted. On each trial, participants judged whether an image presented under conditions of high, medium, or low visual noise showed a piano or a chair. Higher stimulus quality (lower visual noise) was associated with increased activation in bilateral medial occipito-temporal cortex and ventral striatum. Lower stimulus quality was related to stronger activation in posterior parietal cortex (PPC) and dorsolateral prefrontal cortex (DLPFC). When stimulus quality was fixed, faster response times were associated with a positive parametric modulation of activation in medial prefrontal and orbitofrontal cortex, while slower response times were again related to more activation in PPC, DLPFC and insula. Our results suggest that distinct neural networks were sensitive to the quality of stimulus information, and to trial-to-trial variability in the encoded stimulus representations, but that reaching a decision was a consequence of their joint activity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics

    NASA Astrophysics Data System (ADS)

    King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.

    2011-03-01

    The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.

  2. Stress wave sorting of red maple logs for structural quality

    Treesearch

    Xiping Wang; Robert J. Ross; David W. Green; Brian Brashaw; Karl Englund; Michael Wolcott

    2004-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  3. Visual Methods and Quality in Information Behaviour Research: The Cases of Photovoice and Mental Mapping

    ERIC Educational Resources Information Center

    Cox, Andrew; Benson, Melanie

    2017-01-01

    Introduction: The purpose of the paper is to explore the ways in which visual methods can increase the quality of qualitative information behaviour research. Methods: The paper examines Tracy's framework of eight criteria for research quality: worthy topic, rich rigour, sincerity, credibility, resonance, significant contribution, ethical issues…

  4. Effectiveness of mirror therapy, motor imagery, and virtual feedback on phantom limb pain following amputation: A systematic review.

    PubMed

    Herrador Colmenero, Laura; Perez Marmol, Jose Manuel; Martí-García, Celia; Querol Zaldivar, María de Los Ángeles; Tapia Haro, Rosa María; Castro Sánchez, Adelaida María; Aguilar-Ferrándiz, María Encarnación

    2018-06-01

    Phantom limb pain is reported in 50%-85% of people with amputation. Clinical interventions in treating central pain, such as mirror therapy, motor imagery, or virtual visual feedback, could redound in benefits to amputee patients with phantom limb pain. To provide an overview of the effectiveness of different techniques for treating phantom limb pain in amputee patients. Systematic review. A computerized literature search up to April 2017 was performed using the following databases: PubMed, Scopus, CINAHL, MEDLINE, ProQuest, PEDro, EBSCOhost, and Cochrane Plus. Methodological quality and internal validity score of each study were assessed using PEDro scale. For data synthesis, qualitative methods from the Cochrane Back Review Group were applied. In all, 12 studies met our inclusion criteria, where 9 were rated as low methodological quality and 3 rated moderate quality. All studies showed a significant reduction in pain, but there was heterogeneity among subjects and methodologies and any high-quality clinical trial (PEDro score ≤8; internal validity score ≤5) was not found. Mirror therapy, motor imaginary, and virtual visual feedback reduce phantom limb pain; however, there is limited scientific evidence supporting their effectiveness. Future studies should include designs with more solid research methods, exploring short- and long-term benefits of these therapies. Clinical relevance This systematic review investigates the effectiveness of mirror therapy, motor imagery, and virtual visual feedback on phantom limb pain, summarizing the currently published trials and evaluating the research quality. Although these interventions have positive benefits in phantom limb pain, there is still a lack of evidence for supporting their effectiveness.

  5. The Implications of Handling Qualities in Civil Helicopter Accidents Involving Hover and Low Speed Flight

    NASA Technical Reports Server (NTRS)

    Dugan, Daniel C.; Delamer, Kevin J.

    2005-01-01

    Because of increasing accident rates in Army helicopters in hover and low speed flight, a study was made in 1999 of accidents which could be attributed to inadequate stability augmentation. A study of civil helicopter accidents from 1993-2004 was then undertaken to pursue the issue of poor handling qualities in helicopters which, in almost all cases, had no stability augmentation. The vast majority of the mishaps studied occurred during daylight in visual meteorological condition, reducing the impact of degraded visual environments (DVE) on the results. Based on the Cooper-Harper Rating Scale, the handling qualities of many of the helicopters studied could be described as having from "very objectionable" to "major" deficiencies. These costly deficiencies have resulted in unnecessary loss of life, injury, and high dollar damage. Low cost and lightweight augmentation systems for helicopters have been developed in the past and are still being investigated. They offer the potential for significant reductions in the accident rate.

  6. Blind image quality assessment via probabilistic latent semantic analysis.

    PubMed

    Yang, Xichen; Sun, Quansen; Wang, Tianshu

    2016-01-01

    We propose a blind image quality assessment that is highly unsupervised and training free. The new method is based on the hypothesis that the effect caused by distortion can be expressed by certain latent characteristics. Combined with probabilistic latent semantic analysis, the latent characteristics can be discovered by applying a topic model over a visual word dictionary. Four distortion-affected features are extracted to form the visual words in the dictionary: (1) the block-based local histogram; (2) the block-based local mean value; (3) the mean value of contrast within a block; (4) the variance of contrast within a block. Based on the dictionary, the latent topics in the images can be discovered. The discrepancy between the frequency of the topics in an unfamiliar image and a large number of pristine images is applied to measure the image quality. Experimental results for four open databases show that the newly proposed method correlates well with human subjective judgments of diversely distorted images.

  7. Hippocampus Contributes to the Maintenance but Not the Quality of Visual Information over Time

    ERIC Educational Resources Information Center

    Warren, David E.; Duff, Melissa C.; Cohen, Neal J.; Tranel, Daniel

    2015-01-01

    The hippocampus has recently been implicated in the brief representation of visual information, but its specific role is not well understood. We investigated this role using a paradigm that distinguishes quantity and quality of visual memory as described in a previous study. We found that amnesic patients with bilateral hippocampal damage (N = 5)…

  8. Quality, Importance, and Instruction: The Perspectives of Teachers of Students with Visual Impairments on Graphics Use by Students

    ERIC Educational Resources Information Center

    Zebehazy, Kim T.; Wilton, Adam P.

    2014-01-01

    Introduction: This study investigated the perceptions and practices of teachers of students with visual impairments in Canada and the United States regarding graphics (both tactile and print) that are used by students with visual impairments. Questions focused on quality, importance, and instruction in the use of graphics. Methods: An electronic…

  9. Visual functioning and quality of life among the older people in Hong Kong.

    PubMed

    Leung, Jason C S; Kwok, Timothy C Y; Chan, Dicken C C; Yuen, Kay W K; Kwok, Anthony W L; Choy, Dicky T K; Lau, Edith M C; Leung, P C

    2012-08-01

    This study aimed to examine the association of visual functioning and health-related quality of life (HRQOL) among the older community in Hong Kong. This study used the baseline examination of a cohort study MrOs and MsOs (a large study for osteoporosis in men and women). This study was set in the Hong Kong community. A total of 4000 ambulatory community-dwelling Chinese men and women aged 65 years or above participated in this study. Health-related quality of life was assessed by Medical Outcomes Study Short Form-12 (SF-12), with physical component summary (PCS) and mental component summary (MCS) scores. Demographics, medical history, mental status, and quality of life were obtained from face-to-face interviews, using standard structured questionnaire. Visual functions (i.e., binocular visual acuity, contrast sensitivity, and stereopsis) were assessed by different visual tests after refraction corrections. Different visual functions were tested simultaneously in multiple ordinal logistic regression models. Better binocular visual acuity, contrast sensitivity, and stereopsis were associated with higher PCS. Visual acuity and contrast sensitivity was associated with PCS after adjustment of different visual functions and sex, age, education level, cognitive status, and history of diabetes in multivariate analysis, (OR = 0.73, 95% CI = 0.54 0.98) for low vision (≤6/24) compared with ≥6/9 in visual acuity and (OR = 1.34, 95% CI = 1.09 1.64) for contrast sensitivity row b 5-8 (best) compared with 0-1 (worst). MCS was only associated with visual acuity and contrast sensitivity, but no association was found after adjustment. Apparent association was found between visual functions and HRQOL among older community in Hong Kong. In addition to visual acuity, contrast sensitivity is also important, so eye care should also cover. Copyright © 2011 John Wiley & Sons, Ltd.

  10. Corridor One:An Integrated Distance Visualization Enuronments for SSI+ASCI Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher R. Johnson, Charles D. Hansen

    2001-10-29

    The goal of Corridor One: An Integrated Distance Visualization Environment for ASCI and SSI Application was to combine the forces of six leading edge laboratories working in the areas of visualization and distributed computing and high performance networking (Argonne National Laboratory, Lawrence Berkeley National Laboratory, Los Alamos National Laboratory, University of Illinois, University of Utah and Princeton University) to develop and deploy the most advanced integrated distance visualization environment for large-scale scientific visualization and demonstrate it on applications relevant to the DOE SSI and ASCI programs. The Corridor One team brought world class expertise in parallel rendering, deep image basedmore » rendering, immersive environment technology, large-format multi-projector wall based displays, volume and surface visualization algorithms, collaboration tools and streaming media technology, network protocols for image transmission, high-performance networking, quality of service technology and distributed computing middleware. Our strategy was to build on the very successful teams that produced the I-WAY, ''Computational Grids'' and CAVE technology and to add these to the teams that have developed the fastest parallel visualizations systems and the most widely used networking infrastructure for multicast and distributed media. Unfortunately, just as we were getting going on the Corridor One project, DOE cut the program after the first year. As such, our final report consists of our progress during year one of the grant.« less

  11. Surround-Masking Affects Visual Estimation Ability

    PubMed Central

    Jastrzebski, Nicola R.; Hugrass, Laila E.; Crewther, Sheila G.; Crewther, David P.

    2017-01-01

    Visual estimation of numerosity involves the discrimination of magnitude between two distributions or perceptual sets that vary in number of elements. How performance on such estimation depends on peripheral sensory stimulation is unclear, even in typically developing adults. Here, we varied the central and surround contrast of stimuli that comprised a visual estimation task in order to determine whether mechanisms involved with the removal of unessential visual input functionally contributes toward number acuity. The visual estimation judgments of typically developed adults were significantly impaired for high but not low contrast surround stimulus conditions. The center and surround contrasts of the stimuli also differentially affected the accuracy of numerosity estimation depending on whether fewer or more dots were presented. Remarkably, observers demonstrated the highest mean percentage accuracy across stimulus conditions in the discrimination of more elements when the surround contrast was low and the background luminance of the central region containing the elements was dark (black center). Conversely, accuracy was severely impaired during the discrimination of fewer elements when the surround contrast was high and the background luminance of the central region was mid level (gray center). These findings suggest that estimation ability is functionally related to the quality of low-order filtration of unessential visual information. These surround masking results may help understanding of the poor visual estimation ability commonly observed in developmental dyscalculia. PMID:28360845

  12. View compensated compression of volume rendered images for remote visualization.

    PubMed

    Lalgudi, Hariharan G; Marcellin, Michael W; Bilgin, Ali; Oh, Han; Nadar, Mariappan S

    2009-07-01

    Remote visualization of volumetric images has gained importance over the past few years in medical and industrial applications. Volume visualization is a computationally intensive process, often requiring hardware acceleration to achieve a real time viewing experience. One remote visualization model that can accomplish this would transmit rendered images from a server, based on viewpoint requests from a client. For constrained server-client bandwidth, an efficient compression scheme is vital for transmitting high quality rendered images. In this paper, we present a new view compensation scheme that utilizes the geometric relationship between viewpoints to exploit the correlation between successive rendered images. The proposed method obviates motion estimation between rendered images, enabling significant reduction to the complexity of a compressor. Additionally, the view compensation scheme, in conjunction with JPEG2000 performs better than AVC, the state of the art video compression standard.

  13. Developing effective serious games: the effect of background sound on visual fidelity perception with varying texture resolution.

    PubMed

    Rojas, David; Kapralos, Bill; Cristancho, Sayra; Collins, Karen; Hogue, Andrew; Conati, Cristina; Dubrowski, Adam

    2012-01-01

    Despite the benefits associated with virtual learning environments and serious games, there are open, fundamental issues regarding simulation fidelity and multi-modal cue interaction and their effect on immersion, transfer of knowledge, and retention. Here we describe the results of a study that examined the effect of ambient (background) sound on the perception of visual fidelity (defined with respect to texture resolution). Results suggest that the perception of visual fidelity is dependent on ambient sound and more specifically, white noise can have detrimental effects on our perception of high quality visuals. The results of this study will guide future studies that will ultimately aid in developing an understanding of the role that fidelity, and multi-modal interactions play with respect to knowledge transfer and retention for users of virtual simulations and serious games.

  14. Tablet—next generation sequence assembly visualization

    PubMed Central

    Milne, Iain; Bayer, Micha; Cardle, Linda; Shaw, Paul; Stephen, Gordon; Wright, Frank; Marshall, David

    2010-01-01

    Summary: Tablet is a lightweight, high-performance graphical viewer for next-generation sequence assemblies and alignments. Supporting a range of input assembly formats, Tablet provides high-quality visualizations showing data in packed or stacked views, allowing instant access and navigation to any region of interest, and whole contig overviews and data summaries. Tablet is both multi-core aware and memory efficient, allowing it to handle assemblies containing millions of reads, even on a 32-bit desktop machine. Availability: Tablet is freely available for Microsoft Windows, Apple Mac OS X, Linux and Solaris. Fully bundled installers can be downloaded from http://bioinf.scri.ac.uk/tablet in 32- and 64-bit versions. Contact: tablet@scri.ac.uk PMID:19965881

  15. [Comparative analysis of visual function and the quality of life index with eyeglasses or a progressive contact lens].

    PubMed

    Sant'Anna, Neusa Vidal; Schor, Paulo; Lipener, César; Uras, Ricardo

    2006-01-01

    To compare the visual function and the answers to a questionnaire of quality of life of patients wearing a progressive contact lens or eyeglasses. The Focus Progressive contact lens had been fitted in 35 patients with far visual acuity with progressive-addition eyeglasses equal to zero (log MAR) and near J1 (Jaeger). The far and near visual acuities and the measurement of contrast sensitivity were compared when the patients were wearing the eyeglasses or the contact lens and the patients' results of the scores of the quality of life questionnaire (NEI VFQ-25) were analyzed statistically considering the type of ametropy and the age. The far and near visual acuities and the contrast sensitivity measurement were worse with the contact lens than with eyeglasses. The answers to the questionnaire did not differ when were comparing the same patients wearing eyeglasses or contact lens, no matter the type of ametropy. The myopic and the hyperopic subgroups had worse answers to the quality of life questionnaire when corrected with the contact lens than with eyeglasses, both with age equal to or less than their median. The visual function was worse with the contact lens. The type of ametropy did not influence the answers to the quality of life questionnaire considering the optical correction, but age did.

  16. Method and Apparatus for Evaluating the Visual Quality of Processed Digital Video Sequences

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B. (Inventor)

    2002-01-01

    A Digital Video Quality (DVQ) apparatus and method that incorporate a model of human visual sensitivity to predict the visibility of artifacts. The DVQ method and apparatus are used for the evaluation of the visual quality of processed digital video sequences and for adaptively controlling the bit rate of the processed digital video sequences without compromising the visual quality. The DVQ apparatus minimizes the required amount of memory and computation. The input to the DVQ apparatus is a pair of color image sequences: an original (R) non-compressed sequence, and a processed (T) sequence. Both sequences (R) and (T) are sampled, cropped, and subjected to color transformations. The sequences are then subjected to blocking and discrete cosine transformation, and the results are transformed to local contrast. The next step is a time filtering operation which implements the human sensitivity to different time frequencies. The results are converted to threshold units by dividing each discrete cosine transform coefficient by its respective visual threshold. At the next stage the two sequences are subtracted to produce an error sequence. The error sequence is subjected to a contrast masking operation, which also depends upon the reference sequence (R). The masked errors can be pooled in various ways to illustrate the perceptual error over various dimensions, and the pooled error can be converted to a visual quality measure.

  17. Comparative Study of the MTFA, ICS, and SQRI Image Quality Metrics for Visual Display Systems

    DTIC Science & Technology

    1991-09-01

    reasonable image quality predictions across select display and viewing condition parameters. 101 6.0 REFERENCES American National Standard for Human Factors Engineering of ’ Visual Display Terminal Workstations . ANSI

  18. Visual Perception Based Rate Control Algorithm for HEVC

    NASA Astrophysics Data System (ADS)

    Feng, Zeqi; Liu, PengYu; Jia, Kebin

    2018-01-01

    For HEVC, rate control is an indispensably important video coding technology to alleviate the contradiction between video quality and the limited encoding resources during video communication. However, the rate control benchmark algorithm of HEVC ignores subjective visual perception. For key focus regions, bit allocation of LCU is not ideal and subjective quality is unsatisfied. In this paper, a visual perception based rate control algorithm for HEVC is proposed. First bit allocation weight of LCU level is optimized based on the visual perception of luminance and motion to ameliorate video subjective quality. Then λ and QP are adjusted in combination with the bit allocation weight to improve rate distortion performance. Experimental results show that the proposed algorithm reduces average 0.5% BD-BR and maximum 1.09% BD-BR at no cost in bitrate accuracy compared with HEVC (HM15.0). The proposed algorithm devotes to improving video subjective quality under various video applications.

  19. Quality of Vision in Eyes With Epiphora Undergoing Lacrimal Passage Intubation.

    PubMed

    Koh, Shizuka; Inoue, Yasushi; Ochi, Shintaro; Takai, Yoshihiro; Maeda, Naoyuki; Nishida, Kohji

    2017-09-01

    To investigate visual function and optical quality in eyes with epiphora undergoing lacrimal passage intubation. Prospective case series. Thirty-four eyes of 30 patients with lacrimal passage obstruction were enrolled. Before and 1 month after lacrimal passage intubation, functional visual acuity (FVA), higher-order aberrations (HOAs), lower tear meniscus, and tear clearance were assessed. An FVA measurement system was used to examine changes in continuous visual acuity (VA) over time, and visual function parameters such as FVA, visual maintenance ratio, and blink frequency were obtained. Sequential ocular HOAs were measured for 10 seconds after the blink using a wavefront sensor. Aberration data were analyzed in the central 4 mm for coma-like, spherical-like, and total HOAs. Fluctuation and stability indices of the total HOAs over time were calculated. Lower tear meniscus was assessed by anterior segment optical coherence tomography. After lacrimal passage intubation, visual function significantly improved, as indicated by improved FVA (P = .003) and visual maintenance ratio (P < .001). Blink frequency decreased significantly after treatment (P = .01). Optical quality significantly improved, as indicated by a decrease in coma-like aberrations (P = .003), spherical-like aberrations (P = .018), and total HOAs (P = .001). Stability index increased (P < .001) and fluctuation index decreased (P = .019), and tear meniscus dimension decreased (P < .001). Lacrimal passage intubation for eyes with epiphora significantly improved visual function and optical quality via patency of the lacrimal passage. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Enhanced annotations and features for comparing thousands of Pseudomonas genomes in the Pseudomonas genome database.

    PubMed

    Winsor, Geoffrey L; Griffiths, Emma J; Lo, Raymond; Dhillon, Bhavjinder K; Shay, Julie A; Brinkman, Fiona S L

    2016-01-04

    The Pseudomonas Genome Database (http://www.pseudomonas.com) is well known for the application of community-based annotation approaches for producing a high-quality Pseudomonas aeruginosa PAO1 genome annotation, and facilitating whole-genome comparative analyses with other Pseudomonas strains. To aid analysis of potentially thousands of complete and draft genome assemblies, this database and analysis platform was upgraded to integrate curated genome annotations and isolate metadata with enhanced tools for larger scale comparative analysis and visualization. Manually curated gene annotations are supplemented with improved computational analyses that help identify putative drug targets and vaccine candidates or assist with evolutionary studies by identifying orthologs, pathogen-associated genes and genomic islands. The database schema has been updated to integrate isolate metadata that will facilitate more powerful analysis of genomes across datasets in the future. We continue to place an emphasis on providing high-quality updates to gene annotations through regular review of the scientific literature and using community-based approaches including a major new Pseudomonas community initiative for the assignment of high-quality gene ontology terms to genes. As we further expand from thousands of genomes, we plan to provide enhancements that will aid data visualization and analysis arising from whole-genome comparative studies including more pan-genome and population-based approaches. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  1. The Grassmannian Atlas: A General Framework for Exploring Linear Projections of High-Dimensional Data

    DOE PAGES

    Liu, S.; Bremer, P. -T; Jayaraman, J. J.; ...

    2016-06-04

    Linear projections are one of the most common approaches to visualize high-dimensional data. Since the space of possible projections is large, existing systems usually select a small set of interesting projections by ranking a large set of candidate projections based on a chosen quality measure. However, while highly ranked projections can be informative, some lower ranked ones could offer important complementary information. Therefore, selection based on ranking may miss projections that are important to provide a global picture of the data. Here, the proposed work fills this gap by presenting the Grassmannian Atlas, a framework that captures the global structuresmore » of quality measures in the space of all projections, which enables a systematic exploration of many complementary projections and provides new insights into the properties of existing quality measures.« less

  2. Crystalens HD intraocular lens analysis using an adaptive optics visual simulator.

    PubMed

    Pérez-Vives, Cari; Montés-Micó, Robert; López-Gil, Norberto; Ferrer-Blasco, Teresa; García-Lázaro, Santiago

    2013-12-01

    To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were measured for both IOL optics. Near VA (NVA) and CS were measured for the Crystalens HD IOL in its accommodative state. Depth of focus around the distance and near focus was also evaluated for the Crystalens HD IOL. Modulation transfer function (MTF), point spread function (PSF), and Strehl ratio were also calculated. All measures were taken for 3- and 5-mm pupils. The MTF, PSF, and Strehl ratio showed comparable values between IOLs (p > 0.05). There were no significant differences in DVA and CS between IOLs for all contrasts and pupils (p > 0.05). When spherically focused, mean DVA and NVA with the Crystalens HD IOL were ≥20/20 at 100 and 50% contrasts for both pupils. Monocular DVA, NVA, and CS were slightly better with 3- than 5-mm pupils, but without statistically significant differences. The Crystalens HD IOL showed about 0.75 and 0.50 D of depth of focus in its accommodative state and nonaccommodative state, respectively. The optical and visual quality with the nonaccommodatied Crystalens HD IOL was comparable to that of a monofocal IOL. If this lens can move 1.4 mm in the eye, it will provide high-quality optics for near vision as well.

  3. Photography To Enhance Aesthetic Skills.

    ERIC Educational Resources Information Center

    McIsaac, Marina Stock

    Recognizing that photography in the classroom is highly motivating in that it offers a unique vehicle for communicating ideas visually, this study was designed to isolate variables which can be both observed and evaluated in photographs and for which instruction can be designed. Relationships among the technical and aesthetic qualities in…

  4. Video quality assessment using a statistical model of human visual speed perception.

    PubMed

    Wang, Zhou; Li, Qiang

    2007-12-01

    Motion is one of the most important types of information contained in natural video, but direct use of motion information in the design of video quality assessment algorithms has not been deeply investigated. Here we propose to incorporate a recent model of human visual speed perception [Nat. Neurosci. 9, 578 (2006)] and model visual perception in an information communication framework. This allows us to estimate both the motion information content and the perceptual uncertainty in video signals. Improved video quality assessment algorithms are obtained by incorporating the model as spatiotemporal weighting factors, where the weight increases with the information content and decreases with the perceptual uncertainty. Consistent improvement over existing video quality assessment algorithms is observed in our validation with the video quality experts group Phase I test data set.

  5. A Nationwide Cross-Sectional Survey of Sleep-Related Problems in Japanese Visually Impaired Patients: Prevalence and Association with Health-Related Quality of Life

    PubMed Central

    Tamura, Norihisa; Sasai-Sakuma, Taeko; Morita, Yuko; Okawa, Masako; Inoue, Shigeru; Inoue, Yuichi

    2016-01-01

    Study Objectives: This questionnaire-based cross-sectional study was conducted (1) to estimate the prevalence of sleep-related problems, and (2) to explore factors associated with lower physical/mental quality of life (QOL), particularly addressing sleep-related problems among Japanese visually impaired people. Methods: This nationwide questionnaire-based survey was administered to visually impaired individuals through the Japan Federation of the Blind. Visually impaired individuals without light perception (LP) (n = 311), those with LP (n = 287), and age-matched and gender-matched controls (n = 615) were eligible for this study. Study questionnaires elicited demographic information, and information about visual impairment status, sleep-related problems, and health-related quality of life. Results: Visually impaired individuals with and without LP showed higher prevalence rates of irregular sleep-wake patterns and difficulty maintaining sleep than controls (34.7% and 29.4% vs. 15.8%, 60.1% and 46.7% vs. 26.8%, respectively; p < 0.001). These sleep-related problems were observed more frequently in visually impaired individuals without LP than in those with LP. Non-restorative sleep or excessive daytime sleepiness was associated with lower mental/physical QOL in visually impaired individuals with LP and in control subjects. However, visually impaired individuals without LP showed irregular sleep-wake pattern or difficulty waking up at the desired time, which was associated with lower mental/physical QOL. Conclusions: Sleep-related problems were observed more frequently in visually impaired individuals than in controls. Moreover, the rates of difficulties were higher among subjects without LP. Sleep-related problems, especially circadian rhythm-related ones, can be associated with lower mental/physical QOL in visually impaired individuals without LP. Citation: Tamura N, Sasai-Sakuma T, Morita Y, Okawa M, Inoue S, Inoue Y. A nationwide cross-sectional survey of sleep-related problems in Japanese visually impaired patients: prevalence and association with health-related quality of life. J Clin Sleep Med 2016;12(12):1659–1667. PMID:27655465

  6. CTViz: A tool for the visualization of transport in nanocomposites.

    PubMed

    Beach, Benjamin; Brown, Joshua; Tarlton, Taylor; Derosa, Pedro A

    2016-05-01

    A visualization tool (CTViz) for charge transport processes in 3-D hybrid materials (nanocomposites) was developed, inspired by the need for a graphical application to assist in code debugging and data presentation of an existing in-house code. As the simulation code grew, troubleshooting problems grew increasingly difficult without an effective way to visualize 3-D samples and charge transport in those samples. CTViz is able to produce publication and presentation quality visuals of the simulation box, as well as static and animated visuals of the paths of individual carriers through the sample. CTViz was designed to provide a high degree of flexibility in the visualization of the data. A feature that characterizes this tool is the use of shade and transparency levels to highlight important details in the morphology or in the transport paths by hiding or dimming elements of little relevance to the current view. This is fundamental for the visualization of 3-D systems with complex structures. The code presented here provides these required capabilities, but has gone beyond the original design and could be used as is or easily adapted for the visualization of other particulate transport where transport occurs on discrete paths. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Automatic welding of stainless steel tubing

    NASA Technical Reports Server (NTRS)

    Clautice, W. E.

    1978-01-01

    The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.

  8. An Unmanned Aerial Vehicle Cluster Network Cruise System for Monitor

    NASA Astrophysics Data System (ADS)

    Jiang, Jirong; Tao, Jinpeng; Xin, Guipeng

    2018-06-01

    The existing maritime cruising system mainly uses manned motorboats to monitor the quality of coastal water and patrol and maintenance of the navigation -aiding facility, which has the problems of high energy consumption, small range of cruise for monitoring, insufficient information control and low visualization. In recent years, the application of UAS in the maritime field has alleviated the phenomenon above to some extent. A cluster-based unmanned network monitoring cruise system designed in this project uses the floating small UAV self-powered launching platform as a carrier, applys the idea of cluster, and combines the strong controllability of the multi-rotor UAV and the capability to carry customized modules, constituting a unmanned, visualized and normalized monitoring cruise network to realize the functions of maritime cruise, maintenance of navigational-aiding and monitoring the quality of coastal water.

  9. Reconstruction and Visualization of Fiber and Laminar Structure inthe Normal Human Heart from Ex Vivo DTMRI Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rohmer, Damien; Sitek, Arkadiusz; Gullberg, Grant T.

    2006-12-18

    Background - The human heart is composed of a helicalnetwork of muscle fibers. These fibers are organized to form sheets thatare separated by cleavage surfaces. This complex structure of fibers andsheets is responsible for the orthotropic mechanical properties ofcardiac muscle. The understanding of the configuration of the 3D fiberand sheet structure is important for modeling the mechanical andelectrical properties of the heart and changes in this configuration maybe of significant importance to understand the remodeling aftermyocardial infarction.Methods - Anisotropic least square filteringfollowed by fiber and sheet tracking techniques were applied to DiffusionTensor Magnetic Resonance Imaging (DTMRI) data of the excisedmore » humanheart. The fiber configuration was visualized by using thin tubes toincrease 3-dimensional visual perception of the complex structure. Thesheet structures were reconstructed from the DTMRI data, obtainingsurfaces that span the wall from the endo- to the epicardium. Allvisualizations were performed using the high-quality ray-tracing softwarePOV-Ray. Results - The fibers are shown to lie in sheets that haveconcave or convex transmural structure which correspond to histologicalstudies published in the literature. The fiber angles varied depending onthe position between the epi- and endocardium. The sheets had a complexstructure that depended on the location within the myocardium. In theapex region the sheets had more curvature. Conclusions - A high-qualityvisualization algorithm applied to demonstrated high quality DTMRI datais able to elicit the comprehension of the complex 3 dimensionalstructure of the fibers and sheets in the heart.« less

  10. Visual quality analysis for images degraded by different types of noise

    NASA Astrophysics Data System (ADS)

    Ponomarenko, Nikolay N.; Lukin, Vladimir V.; Ieremeyev, Oleg I.; Egiazarian, Karen O.; Astola, Jaakko T.

    2013-02-01

    Modern visual quality metrics take into account different peculiarities of the Human Visual System (HVS). One of them is described by the Weber-Fechner law and deals with the different sensitivity to distortions in image fragments with different local mean values (intensity, brightness). We analyze how this property can be incorporated into a metric PSNRHVS- M. It is shown that some improvement of its performance can be provided. Then, visual quality of color images corrupted by three types of i.i.d. noise (pure additive, pure multiplicative, and signal dependent, Poisson) is analyzed. Experiments with a group of observers are carried out for distorted color images created on the basis of TID2008 database. Several modern HVS-metrics are considered. It is shown that even the best metrics are unable to assess visual quality of distorted images adequately enough. The reasons for this deal with the observer's attention to certain objects in the test images, i.e., with semantic aspects of vision, which are worth taking into account in design of HVS-metrics.

  11. Subjective evaluation of two stereoscopic imaging systems exploiting visual attention to improve 3D quality of experience

    NASA Astrophysics Data System (ADS)

    Hanhart, Philippe; Ebrahimi, Touradj

    2014-03-01

    Crosstalk and vergence-accommodation rivalry negatively impact the quality of experience (QoE) provided by stereoscopic displays. However, exploiting visual attention and adapting the 3D rendering process on the fly can reduce these drawbacks. In this paper, we propose and evaluate two different approaches that exploit visual attention to improve 3D QoE on stereoscopic displays: an offline system, which uses a saliency map to predict gaze position, and an online system, which uses a remote eye tracking system to measure real time gaze positions. The gaze points were used in conjunction with the disparity map to extract the disparity of the object-of-interest. Horizontal image translation was performed to bring the fixated object on the screen plane. The user preference between standard 3D mode and the two proposed systems was evaluated through a subjective evaluation. Results show that exploiting visual attention significantly improves image quality and visual comfort, with a slight advantage for real time gaze determination. Depth quality is also improved, but the difference is not significant.

  12. Association of consumers' sex and eyedness and lighting and wall color of a store with price attraction and perceived quality of goods and inside visual appeal.

    PubMed

    Barli, Onder; Bilgili, Bilsen; Dane, Senol

    2006-10-01

    The associations of sex and eyedness of consumers in a market and the market's lighting and wall color with price attraction and perceived quality of goods and the inside visual appeal were studied using an inventory after shopping by 440 men and 478 women, 20 to 60 years old (M = 29.3, SD = 10.2). Two lights (soft and bright) and 4 colors (blue, yellow, green, and red) and neutral light (white) were used. Women rated the prices of goods more attractive compared to men. In the total sample, left-eye preferents rated visual appeal higher compared to right-eye preferents. Bright light was associated with higher visual appeal than soft light. Green was associated with the highest inside visual appeal and perceived quality of goods, which may be due to its intermediate wavelength.

  13. ProXL (Protein Cross-Linking Database): A Platform for Analysis, Visualization, and Sharing of Protein Cross-Linking Mass Spectrometry Data

    PubMed Central

    2016-01-01

    ProXL is a Web application and accompanying database designed for sharing, visualizing, and analyzing bottom-up protein cross-linking mass spectrometry data with an emphasis on structural analysis and quality control. ProXL is designed to be independent of any particular software pipeline. The import process is simplified by the use of the ProXL XML data format, which shields developers of data importers from the relative complexity of the relational database schema. The database and Web interfaces function equally well for any software pipeline and allow data from disparate pipelines to be merged and contrasted. ProXL includes robust public and private data sharing capabilities, including a project-based interface designed to ensure security and facilitate collaboration among multiple researchers. ProXL provides multiple interactive and highly dynamic data visualizations that facilitate structural-based analysis of the observed cross-links as well as quality control. ProXL is open-source, well-documented, and freely available at https://github.com/yeastrc/proxl-web-app. PMID:27302480

  14. ProXL (Protein Cross-Linking Database): A Platform for Analysis, Visualization, and Sharing of Protein Cross-Linking Mass Spectrometry Data.

    PubMed

    Riffle, Michael; Jaschob, Daniel; Zelter, Alex; Davis, Trisha N

    2016-08-05

    ProXL is a Web application and accompanying database designed for sharing, visualizing, and analyzing bottom-up protein cross-linking mass spectrometry data with an emphasis on structural analysis and quality control. ProXL is designed to be independent of any particular software pipeline. The import process is simplified by the use of the ProXL XML data format, which shields developers of data importers from the relative complexity of the relational database schema. The database and Web interfaces function equally well for any software pipeline and allow data from disparate pipelines to be merged and contrasted. ProXL includes robust public and private data sharing capabilities, including a project-based interface designed to ensure security and facilitate collaboration among multiple researchers. ProXL provides multiple interactive and highly dynamic data visualizations that facilitate structural-based analysis of the observed cross-links as well as quality control. ProXL is open-source, well-documented, and freely available at https://github.com/yeastrc/proxl-web-app .

  15. Perceptually tuned low-bit-rate video codec for ATM networks

    NASA Astrophysics Data System (ADS)

    Chou, Chun-Hsien

    1996-02-01

    In order to maintain high visual quality in transmitting low bit-rate video signals over asynchronous transfer mode (ATM) networks, a layered coding scheme that incorporates the human visual system (HVS), motion compensation (MC), and conditional replenishment (CR) is presented in this paper. An empirical perceptual model is proposed to estimate the spatio- temporal just-noticeable distortion (STJND) profile for each frame, by which perceptually important (PI) prediction-error signals can be located. Because of the limited channel capacity of the base layer, only coded data of motion vectors, the PI signals within a small strip of the prediction-error image and, if there are remaining bits, the PI signals outside the strip are transmitted by the cells of the base-layer channel. The rest of the coded data are transmitted by the second-layer cells which may be lost due to channel error or network congestion. Simulation results show that visual quality of the reconstructed CIF sequence is acceptable when the capacity of the base-layer channel is allocated with 2 multiplied by 64 kbps and the cells of the second layer are all lost.

  16. A system verification platform for high-density epiretinal prostheses.

    PubMed

    Chen, Kuanfu; Lo, Yi-Kai; Yang, Zhi; Weiland, James D; Humayun, Mark S; Liu, Wentai

    2013-06-01

    Retinal prostheses have restored light perception to people worldwide who have poor or no vision as a consequence of retinal degeneration. To advance the quality of visual stimulation for retinal implant recipients, a higher number of stimulation channels is expected in the next generation retinal prostheses, which poses a great challenge to system design and verification. This paper presents a system verification platform dedicated to the development of retinal prostheses. The system includes primary processing, dual-band power and data telemetry, a high-density stimulator array, and two methods for output verification. End-to-end system validation and individual functional block characterization can be achieved with this platform through visual inspection and software analysis. Custom-built software running on the computers also provides a good way for testing new features before they are realized by the ICs. Real-time visual feedbacks through the video displays make it easy to monitor and debug the system. The characterization of the wireless telemetry and the demonstration of the visual display are reported in this paper using a 256-channel retinal prosthetic IC as an example.

  17. Clustervision: Visual Supervision of Unsupervised Clustering.

    PubMed

    Kwon, Bum Chul; Eysenbach, Ben; Verma, Janu; Ng, Kenney; De Filippi, Christopher; Stewart, Walter F; Perer, Adam

    2018-01-01

    Clustering, the process of grouping together similar items into distinct partitions, is a common type of unsupervised machine learning that can be useful for summarizing and aggregating complex multi-dimensional data. However, data can be clustered in many ways, and there exist a large body of algorithms designed to reveal different patterns. While having access to a wide variety of algorithms is helpful, in practice, it is quite difficult for data scientists to choose and parameterize algorithms to get the clustering results relevant for their dataset and analytical tasks. To alleviate this problem, we built Clustervision, a visual analytics tool that helps ensure data scientists find the right clustering among the large amount of techniques and parameters available. Our system clusters data using a variety of clustering techniques and parameters and then ranks clustering results utilizing five quality metrics. In addition, users can guide the system to produce more relevant results by providing task-relevant constraints on the data. Our visual user interface allows users to find high quality clustering results, explore the clusters using several coordinated visualization techniques, and select the cluster result that best suits their task. We demonstrate this novel approach using a case study with a team of researchers in the medical domain and showcase that our system empowers users to choose an effective representation of their complex data.

  18. The effect of texture granularity on texture synthesis quality

    NASA Astrophysics Data System (ADS)

    Golestaneh, S. Alireza; Subedar, Mahesh M.; Karam, Lina J.

    2015-09-01

    Natural and artificial textures occur frequently in images and in video sequences. Image/video coding systems based on texture synthesis can make use of a reliable texture synthesis quality assessment method in order to improve the compression performance in terms of perceived quality and bit-rate. Existing objective visual quality assessment methods do not perform satisfactorily when predicting the synthesized texture quality. In our previous work, we showed that texture regularity can be used as an attribute for estimating the quality of synthesized textures. In this paper, we study the effect of another texture attribute, namely texture granularity, on the quality of synthesized textures. For this purpose, subjective studies are conducted to assess the quality of synthesized textures with different levels (low, medium, high) of perceived texture granularity using different types of texture synthesis methods.

  19. The Aeroflex: A Bicycle for Mobile Air Quality Measurements

    PubMed Central

    Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484

  20. The Aeroflex: a bicycle for mobile air quality measurements.

    PubMed

    Elen, Bart; Peters, Jan; Poppel, Martine Van; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2012-12-24

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. 

  1. Quality labeled faces in the wild (QLFW): a database for studying face recognition in real-world environments

    NASA Astrophysics Data System (ADS)

    Karam, Lina J.; Zhu, Tong

    2015-03-01

    The varying quality of face images is an important challenge that limits the effectiveness of face recognition technology when applied in real-world applications. Existing face image databases do not consider the effect of distortions that commonly occur in real-world environments. This database (QLFW) represents an initial attempt to provide a set of labeled face images spanning the wide range of quality, from no perceived impairment to strong perceived impairment for face detection and face recognition applications. Types of impairment include JPEG2000 compression, JPEG compression, additive white noise, Gaussian blur and contrast change. Subjective experiments are conducted to assess the perceived visual quality of faces under different levels and types of distortions and also to assess the human recognition performance under the considered distortions. One goal of this work is to enable automated performance evaluation of face recognition technologies in the presence of different types and levels of visual distortions. This will consequently enable the development of face recognition systems that can operate reliably on real-world visual content in the presence of real-world visual distortions. Another goal is to enable the development and assessment of visual quality metrics for face images and for face detection and recognition applications.

  2. A unified data representation theory for network visualization, ordering and coarse-graining

    PubMed Central

    Kovács, István A.; Mizsei, Réka; Csermely, Péter

    2015-01-01

    Representation of large data sets became a key question of many scientific disciplines in the last decade. Several approaches for network visualization, data ordering and coarse-graining accomplished this goal. However, there was no underlying theoretical framework linking these problems. Here we show an elegant, information theoretic data representation approach as a unified solution of network visualization, data ordering and coarse-graining. The optimal representation is the hardest to distinguish from the original data matrix, measured by the relative entropy. The representation of network nodes as probability distributions provides an efficient visualization method and, in one dimension, an ordering of network nodes and edges. Coarse-grained representations of the input network enable both efficient data compression and hierarchical visualization to achieve high quality representations of larger data sets. Our unified data representation theory will help the analysis of extensive data sets, by revealing the large-scale structure of complex networks in a comprehensible form. PMID:26348923

  3. Visualization of volumetric seismic data

    NASA Astrophysics Data System (ADS)

    Spickermann, Dela; Böttinger, Michael; Ashfaq Ahmed, Khawar; Gajewski, Dirk

    2015-04-01

    Mostly driven by demands of high quality subsurface imaging, highly specialized tools and methods have been developed to support the processing, visualization and interpretation of seismic data. 3D seismic data acquisition and 4D time-lapse seismic monitoring are well-established techniques in academia and industry, producing large amounts of data to be processed, visualized and interpreted. In this context, interactive 3D visualization methods proved to be valuable for the analysis of 3D seismic data cubes - especially for sedimentary environments with continuous horizons. In crystalline and hard rock environments, where hydraulic stimulation techniques may be applied to produce geothermal energy, interpretation of the seismic data is a more challenging problem. Instead of continuous reflection horizons, the imaging targets are often steep dipping faults, causing a lot of diffractions. Without further preprocessing these geological structures are often hidden behind the noise in the data. In this PICO presentation we will present a workflow consisting of data processing steps, which enhance the signal-to-noise ratio, followed by a visualization step based on the use the commercially available general purpose 3D visualization system Avizo. Specifically, we have used Avizo Earth, an extension to Avizo, which supports the import of seismic data in SEG-Y format and offers easy access to state-of-the-art 3D visualization methods at interactive frame rates, even for large seismic data cubes. In seismic interpretation using visualization, interactivity is a key requirement for understanding complex 3D structures. In order to enable an easy communication of the insights gained during the interactive visualization process, animations of the visualized data were created which support the spatial understanding of the data.

  4. Texas lignite and the visual resource: an objective approach to visual resource evaluation and management

    Treesearch

    Harlow C. Landphair

    1979-01-01

    This paper relates the evolution of an empirical model used to predict public response to scenic quality objectively. The text relates the methods used to develop the visual quality index model, explains the terms used in the equation and briefly illustrates how the model is applied and how it is tested. While the technical application of the model relies heavily on...

  5. Health-Terrain: Visualizing Large Scale Health Data

    DTIC Science & Technology

    2014-12-01

    systems can only be realized if the quality of emerging large medical databases can be characterized and the meaning of the data understood. For this...Designed and tested an evaluation procedure for health data visualization system. This visualization framework offers a real time and web-based solution...rule is shown in the table, with the quality measures of each rule including the support, confidence, Laplace, Gain, p-s, lift and Conviction. We

  6. Associations among visual acuity and vision- and health-related quality of life among patients in the multicenter uveitis steroid treatment trial.

    PubMed

    Frick, Kevin D; Drye, Lea T; Kempen, John H; Dunn, James P; Holland, Gary N; Latkany, Paul; Rao, Narsing A; Sen, H Nida; Sugar, Elizabeth A; Thorne, Jennifer E; Wang, Robert C; Holbrook, Janet T

    2012-03-01

    To evaluate the associations between visual acuity and self-reported visual function; visual acuity and health-related quality of life (QoL) metrics; a summary measure of self-reported visual function and health-related QoL; and individual domains of self-reported visual function and health-related QoL in patients with uveitis. Best-corrected visual acuity, vision-related functioning as assessed by the NEI VFQ-25, and health-related QoL as assessed by the SF-36 and EuroQoL EQ-5D questionnaires were obtained at enrollment in a clinical trial of uveitis treatments. Multivariate regression and Spearman correlations were used to evaluate associations between visual acuity, vision-related function, and health-related QoL. Among the 255 patients, median visual acuity in the better-seeing eyes was 20/25, the vision-related function score indicated impairment (median, 60), and health-related QoL scores were within the normal population range. Better visual acuity was predictive of higher visual function scores (P ≤ 0.001), a higher SF-36 physical component score, and a higher EQ-5D health utility score (P < 0.001). The vision-specific function score was predictive of all general health-related QoL (P < 0.001). The correlations between visual function score and general quality of life measures were moderate (ρ = 0.29-0.52). The vision-related function score correlated positively with visual acuity and moderately positively with general QoL measures. Cost-utility analyses relying on changes in generic healthy utility measures will be more likely to detect changes when there are clinically meaningful changes in vision-related function, rather than when there are only changes in visual acuity. (ClinicalTrials.gov number, NCT00132691.).

  7. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    NASA Astrophysics Data System (ADS)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.

  8. Urodynamic catheter moisture sensor: A novel device to improve leak point pressure detection.

    PubMed

    Marshall, Blake R; Arlen, Angela M; Kirsch, Andrew J

    2016-06-01

    High-quality urodynamic studies in patients with neurogenic lower urinary tract dysfunction are important, as UDS may be the only reliable gauge of potential risk for upper tract deterioration and the optimal tool to guide lower urinary tract management. Reliance on direct visualization of leakage during typical UDS remains a potential source of error. Given the necessity of accurate leak point pressures, we developed a wireless leak detection sensor to eliminate the need for visual inspection during UDS. A mean decrease in detrusor leak point pressure of 3 cm/H2 0 and a mean 11% decrease in capacity at leakage was observed when employing the sensor compared to visual inspection in children undergoing two fillings during a single UDS session. Removing the visual inspection component of UDS may improve accuracy of pressure readings. Neurourol. Urodynam. 35:647-648, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  9. Effect of tone mapping operators on visual attention deployment

    NASA Astrophysics Data System (ADS)

    Narwaria, Manish; Perreira Da Silva, Matthieu; Le Callet, Patrick; Pepion, Romuald

    2012-10-01

    High Dynamic Range (HDR) images/videos require the use of a tone mapping operator (TMO) when visualized on Low Dynamic Range (LDR) displays. From an artistic intention point of view, TMOs are not necessarily transparent and might induce different behavior to view the content. In this paper, we investigate and quantify how TMOs modify visual attention (VA). To that end both objective and subjective tests in the form of eye-tracking experiments have been conducted on several still image content that have been processed by 11 different TMOs. Our studies confirm that TMOs can indeed modify human attention and fixation behavior significantly. Therefore our studies suggest that VA needs consideration for evaluating the overall perceptual impact of TMOs on HDR content. Since the existing studies so far have only considered the quality or aesthetic appeal angle, this study brings in a new perspective regarding the importance of VA in HDR content processing for visualization on LDR displays.

  10. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment

    PubMed Central

    Lee, Christine; Tu, Hong Anh; Weir, Mark; Holubowich, Corinne

    2016-01-01

    Background Retinitis pigmentosa is a group of genetic disorders that involves the breakdown and loss of photoreceptors in the retina, resulting in progressive retinal degeneration and eventual blindness. The Argus II Retinal Prosthesis System is the only currently available surgical implantable device approved by Health Canada. It has been shown to improve visual function in patients with severe visual loss from advanced retinitis pigmentosa. The objective of this analysis was to examine the clinical effectiveness, cost-effectiveness, budget impact, and safety of the Argus II system in improving visual function, as well as exploring patient experiences with the system. Methods We performed a systematic search of the literature for studies examining the effects of the Argus II retinal prosthesis system in patients with advanced retinitis pigmentosa, and appraised the evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria, focusing on visual function, functional outcomes, quality of life, and adverse events. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care over a 10-year time horizon. We also conducted a 5-year budget impact analysis. We used a qualitative design and an interview methodology to examine patients’ lived experience, and we used a modified grounded theory methodology to analyze information from interviews. Transcripts were coded, and themes were compared against one another. Results One multicentre international study and one single-centre study were included in the clinical review. In both studies, patients showed improved visual function with the Argus II system. However, the sight-threatening surgical complication rate was substantial. In the base-case analysis, the Argus II system was cost-effective compared with standard care only if willingness-to-pay was more than $207,616 per quality-adjusted life-year. The 5-year budget impact of funding the Argus II system ranged from $800,404 to $837,596. Retinitis pigmentosa significantly affects people's ability to navigate physical and virtual environments. Argus II was described as enabling the fundamental elements of sight. As such, it had a positive impact on quality of life for people with retinitis pigmentosa. Conclusions Based on evidence of moderate quality, patients with advanced retinitis pigmentosa who were implanted with the Argus II retinal prosthesis system showed significant improvement in visual function, real-life functional outcomes, and quality of life, but there were complications associated with the surgery that could be managed through standard ophthalmologic treatments. The costs for the technology are high. PMID:27468325

  11. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment.

    PubMed

    2016-01-01

    Retinitis pigmentosa is a group of genetic disorders that involves the breakdown and loss of photoreceptors in the retina, resulting in progressive retinal degeneration and eventual blindness. The Argus II Retinal Prosthesis System is the only currently available surgical implantable device approved by Health Canada. It has been shown to improve visual function in patients with severe visual loss from advanced retinitis pigmentosa. The objective of this analysis was to examine the clinical effectiveness, cost-effectiveness, budget impact, and safety of the Argus II system in improving visual function, as well as exploring patient experiences with the system. We performed a systematic search of the literature for studies examining the effects of the Argus II retinal prosthesis system in patients with advanced retinitis pigmentosa, and appraised the evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria, focusing on visual function, functional outcomes, quality of life, and adverse events. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care over a 10-year time horizon. We also conducted a 5-year budget impact analysis. We used a qualitative design and an interview methodology to examine patients' lived experience, and we used a modified grounded theory methodology to analyze information from interviews. Transcripts were coded, and themes were compared against one another. One multicentre international study and one single-centre study were included in the clinical review. In both studies, patients showed improved visual function with the Argus II system. However, the sight-threatening surgical complication rate was substantial. In the base-case analysis, the Argus II system was cost-effective compared with standard care only if willingness-to-pay was more than $207,616 per quality-adjusted life-year. The 5-year budget impact of funding the Argus II system ranged from $800,404 to $837,596. Retinitis pigmentosa significantly affects people's ability to navigate physical and virtual environments. Argus II was described as enabling the fundamental elements of sight. As such, it had a positive impact on quality of life for people with retinitis pigmentosa. Based on evidence of moderate quality, patients with advanced retinitis pigmentosa who were implanted with the Argus II retinal prosthesis system showed significant improvement in visual function, real-life functional outcomes, and quality of life, but there were complications associated with the surgery that could be managed through standard ophthalmologic treatments. The costs for the technology are high.

  12. Calculating the quality of public high-throughput sequencing data to obtain a suitable subset for reanalysis from the Sequence Read Archive

    PubMed Central

    Nakazato, Takeru; Bono, Hidemasa

    2017-01-01

    Abstract It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. PMID:28449062

  13. Image quality metrics for volumetric laser displays

    NASA Astrophysics Data System (ADS)

    Williams, Rodney D.; Donohoo, Daniel

    1991-08-01

    This paper addresses the extensions to the image quality metrics and related human factors research that are needed to establish the baseline standards for emerging volume display technologies. The existing and recently developed technologies for multiplanar volume displays are reviewed with an emphasis on basic human visual issues. Human factors image quality metrics and guidelines are needed to firmly establish this technology in the marketplace. The human visual requirements and the display design tradeoffs for these prototype laser-based volume displays are addressed and several critical image quality issues identified for further research. The American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (ANSIHFS-100) and other international standards (ISO, DIN) can serve as a starting point, but this research base must be extended to provide new image quality metrics for this new technology for volume displays.

  14. Imaging Carbon Nanotubes in High Performance Polymer Composites via Magnetic Force Microscope

    NASA Technical Reports Server (NTRS)

    Lillehei, Peter T.; Park, Cheol; Rouse, Jason H.; Siochi, Emilie J.; Bushnell, Dennis M. (Technical Monitor)

    2002-01-01

    Application of carbon nanotubes as reinforcement in structural composites is dependent on the efficient dispersion of the nanotubes in a high performance polymer matrix. The characterization of such dispersion is limited by the lack of available tools to visualize the quality of the matrix/carbon nanotube interaction. The work reported herein demonstrates the use of magnetic force microscopy (MFM) as a promising technique for characterizing the dispersion of nanotubes in a high performance polymer matrix.

  15. The changing pattern of cataract surgery indications: a 5-year study of 2 cataract surgery databases.

    PubMed

    Lundström, Mats; Goh, Pik-Pin; Henry, Ype; Salowi, Mohamad A; Barry, Peter; Manning, Sonia; Rosen, Paul; Stenevi, Ulf

    2015-01-01

    The aim of this study was to describe changes over time in the indications and outcomes of cataract surgery and to discuss optimal timing for the surgery. Database study. Patients who had undergone cataract extraction in the Netherlands, Sweden, or Malaysia from 2008 through 2012. We analyzed preoperative, surgical, and postoperative data from 2 databases: the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO) and the Malaysian National Cataract Registry. The EUREQUO contains complete data from the national cataract registries in the Netherlands and Sweden. Preoperative and postoperative corrected distance visual acuity, preoperative ocular comorbidity in the surgery eye, and capsule complications during surgery. There were substantial differences in indication for surgery between the 3 national data sets. The percentage of eyes with a preoperative best-corrected visual acuity of 20/200 or worse varied from 7.1% to 72%. In all 3 data sets, the visual thresholds for cataract surgery decreased over time by 6% to 28% of the baseline values. The frequency of capsule complications varied between the 3 data sets, from 1.1% to 3.7% in 2008 and from 0.6% to 2.7% in 2012. An increasing postoperative visual acuity was also seen for all 3 data sets. A high frequency of capsule complication was related significantly to poor preoperative visual acuity, and a high frequency of decreased visual acuity after surgery was related significantly to excellent preoperative visual acuity. The 5-year trend in all 3 national data sets showed decreasing visual thresholds for surgery, decreasing surgical complication rates, and increasing visual outcomes regardless of the initial preoperative visual level. Cataract surgery on eyes with poor preoperative visual acuity was related to surgical complications, and cataract surgery on eyes with excellent preoperative visual acuity was related to adverse visual results. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Optical cylinder designs to increase the field of vision in the osteo-odonto-keratoprosthesis.

    PubMed

    Hull, C C; Liu, C S; Sciscio, A; Eleftheriadis, H; Herold, J

    2000-12-01

    The single optical cylinders used in the osteo-odonto-keratoprosthesis (OOKP) are known to produce very small visual fields. Values of 40 degrees are typically quoted. The purpose of this paper is to present designs for new optical cylinders that significantly increase the field of view and therefore improve the visual rehabilitation of patients having an OOKP. Computer ray-tracing techniques were used to design and analyse improved one- and two-piece optical cylinders made from polymethyl methacrylate. All designs were required to have a potential visual acuity of 6/6 before consideration was given to the visual field and optimising off-axis image quality. Aspheric surfaces were used where this significantly improved off-axis image quality. Single optical cylinders, with increased posterior cylinder (intraocular) diameters, gave an increase in the theoretical visual field of 18% (from 76 degrees to 90 degrees) over current designs. Two-piece designs based on an inverted telephoto principle gave theoretical field angles over 120 degrees. Aspheric surfaces were shown to improve the off-axis image quality while maintaining a potential visual acuity of at least 6/6. This may well increase the measured visual field by improving the retinal illuminance off-axis. Results demonstrate that it is possible to significantly increase the theoretical maximum visual field through OOKP optical cylinders. Such designs will improve the visual rehabilitation of patients undergoing this procedure.

  17. FISH Oracle: a web server for flexible visualization of DNA copy number data in a genomic context.

    PubMed

    Mader, Malte; Simon, Ronald; Steinbiss, Sascha; Kurtz, Stefan

    2011-07-28

    The rapidly growing amount of array CGH data requires improved visualization software supporting the process of identifying candidate cancer genes. Optimally, such software should work across multiple microarray platforms, should be able to cope with data from different sources and should be easy to operate. We have developed a web-based software FISH Oracle to visualize data from multiple array CGH experiments in a genomic context. Its fast visualization engine and advanced web and database technology supports highly interactive use. FISH Oracle comes with a convenient data import mechanism, powerful search options for genomic elements (e.g. gene names or karyobands), quick navigation and zooming into interesting regions, and mechanisms to export the visualization into different high quality formats. These features make the software especially suitable for the needs of life scientists. FISH Oracle offers a fast and easy to use visualization tool for array CGH and SNP array data. It allows for the identification of genomic regions representing minimal common changes based on data from one or more experiments. FISH Oracle will be instrumental to identify candidate onco and tumor suppressor genes based on the frequency and genomic position of DNA copy number changes. The FISH Oracle application and an installed demo web server are available at http://www.zbh.uni-hamburg.de/fishoracle.

  18. FISH Oracle: a web server for flexible visualization of DNA copy number data in a genomic context

    PubMed Central

    2011-01-01

    Background The rapidly growing amount of array CGH data requires improved visualization software supporting the process of identifying candidate cancer genes. Optimally, such software should work across multiple microarray platforms, should be able to cope with data from different sources and should be easy to operate. Results We have developed a web-based software FISH Oracle to visualize data from multiple array CGH experiments in a genomic context. Its fast visualization engine and advanced web and database technology supports highly interactive use. FISH Oracle comes with a convenient data import mechanism, powerful search options for genomic elements (e.g. gene names or karyobands), quick navigation and zooming into interesting regions, and mechanisms to export the visualization into different high quality formats. These features make the software especially suitable for the needs of life scientists. Conclusions FISH Oracle offers a fast and easy to use visualization tool for array CGH and SNP array data. It allows for the identification of genomic regions representing minimal common changes based on data from one or more experiments. FISH Oracle will be instrumental to identify candidate onco and tumor suppressor genes based on the frequency and genomic position of DNA copy number changes. The FISH Oracle application and an installed demo web server are available at http://www.zbh.uni-hamburg.de/fishoracle. PMID:21884636

  19. Applying Semantics in Dataset Summarization for Solar Data Ingest Pipelines

    NASA Astrophysics Data System (ADS)

    Michaelis, J.; McGuinness, D. L.; Zednik, S.; West, P.; Fox, P. A.

    2012-12-01

    One goal in studying phenomena of the solar corona (e.g., flares, coronal mass ejections) is to create and refine predictive models of space weather - which have broad implications for terrestrial activity (e.g., communication grid reliability). The High Altitude Observatory (HAO) [1] presently maintains an infrastructure for generating time-series visualizations of the solar corona. Through raw data gathered at the Mauna Loa Solar Observatory (MLSO) in Hawaii, HAO performs follow-up processing and quality control steps to derive visualization sets consumable by scientists. Individual visualizations will acquire several properties during their derivation, including: (i) the source instrument at MLSO used to obtain the raw data, (ii) the time the data was gathered, (iii) processing steps applied by HAO to generate the visualization, and (iv) quality metrics applied over both the raw and processed data. In parallel to MLSO's standard data gathering, time stamped observation logs are maintained by MLSO staff, which covers content of potential relevance to data gathered (such as local weather and instrument conditions). In this setting, while a significant amount of solar data is gathered, only small sections will typically be of interest to consuming parties. Additionally, direct presentation of solar data collections could overwhelm consumers (particularly those with limited background in the data structuring). This work explores how multidimensional analysis based navigation can be used to generate summary views of data collections, based on two operations: (i) grouping visualization entries based on similarity metrics (e.g., data gathered between 23:15-23:30 6-21-2012), or (ii) filtering entries (e.g., data with a quality score of UGLY, on a scale of GOOD, BAD, or UGLY). Here, semantic encodings of solar visualization collections (based on the Resource Description Framework (RDF) Datacube vocabulary [2]) are being utilized, based on the flexibility of the RDF model for supporting the following use cases: (i) Temporal alignment of time-stamped MLSO observations with raw data gathered at MLSO. (ii) Linking of multiple visualization entries to common (and structurally complex) workflow structures - designed to capture the visualization generation process. To provide real-world use cases for the described approach, a semantic summarization system is being developed for data gathered from HAO's Coronal Multi-channel Polarimeter (CoMP) and Chromospheric Helium-I Imaging Photometer (CHIP) pipelines. Web Links: [1] http://mlso.hao.ucar.edu/ [2] http://www.w3.org/TR/vocab-data-cube/

  20. Screen-Space Normal Distribution Function Caching for Consistent Multi-Resolution Rendering of Large Particle Data.

    PubMed

    Ibrahim, Mohamed; Wickenhauser, Patrick; Rautek, Peter; Reina, Guido; Hadwiger, Markus

    2018-01-01

    Molecular dynamics (MD) simulations are crucial to investigating important processes in physics and thermodynamics. The simulated atoms are usually visualized as hard spheres with Phong shading, where individual particles and their local density can be perceived well in close-up views. However, for large-scale simulations with 10 million particles or more, the visualization of large fields-of-view usually suffers from strong aliasing artifacts, because the mismatch between data size and output resolution leads to severe under-sampling of the geometry. Excessive super-sampling can alleviate this problem, but is prohibitively expensive. This paper presents a novel visualization method for large-scale particle data that addresses aliasing while enabling interactive high-quality rendering. We introduce the novel concept of screen-space normal distribution functions (S-NDFs) for particle data. S-NDFs represent the distribution of surface normals that map to a given pixel in screen space, which enables high-quality re-lighting without re-rendering particles. In order to facilitate interactive zooming, we cache S-NDFs in a screen-space mipmap (S-MIP). Together, these two concepts enable interactive, scale-consistent re-lighting and shading changes, as well as zooming, without having to re-sample the particle data. We show how our method facilitates the interactive exploration of real-world large-scale MD simulation data in different scenarios.

  1. Information theoretical assessment of visual communication with subband coding

    NASA Astrophysics Data System (ADS)

    Rahman, Zia-ur; Fales, Carl L.; Huck, Friedrich O.

    1994-09-01

    A well-designed visual communication channel is one which transmits the most information about a radiance field with the fewest artifacts. The role of image processing, encoding and restoration is to improve the quality of visual communication channels by minimizing the error in the transmitted data. Conventionally this role has been analyzed strictly in the digital domain neglecting the effects of image-gathering and image-display devices on the quality of the image. This results in the design of a visual communication channel which is `suboptimal.' We propose an end-to-end assessment of the imaging process which incorporates the influences of these devices in the design of the encoder and the restoration process. This assessment combines Shannon's communication theory with Wiener's restoration filter and with the critical design factors of the image gathering and display devices, thus providing the metrics needed to quantify and optimize the end-to-end performance of the visual communication channel. Results show that the design of the image-gathering device plays a significant role in determining the quality of the visual communication channel and in designing the analysis filters for subband encoding.

  2. Towards the construction of high-quality mutagenesis libraries.

    PubMed

    Li, Heng; Li, Jing; Jin, Ruinan; Chen, Wei; Liang, Chaoning; Wu, Jieyuan; Jin, Jian-Ming; Tang, Shuang-Yan

    2018-07-01

    To improve the quality of mutagenesis libraries in directed evolution strategy. In the process of library transformation, transformants which have been shown to take up more than one plasmid might constitute more than 20% of the constructed library, thereby extensively impairing the quality of the library. We propose a practical transformation method to prevent the occurrence of multiple-plasmid transformants while maintaining high transformation efficiency. A visual library model containing plasmids expressing different fluorescent proteins was used. Multiple-plasmid transformants can be reduced through optimizing plasmid DNA amount used for transformation based on the positive correlation between the occurrence frequency of multiple-plasmid transformants and the logarithmic ratio of plasmid molecules to competent cells. This method provides a simple solution for a seemingly common but often neglected problem, and should be valuable for improving the quality of mutagenesis libraries to enhance the efficiency of directed evolution strategies.

  3. Image quality evaluation for smart-phone displays at lighting levels of indoor and outdoor conditions

    NASA Astrophysics Data System (ADS)

    Gong, Rui; Xu, Haisong; Wang, Binyu; Luo, Ming Ronnier

    2012-08-01

    The image quality of two active matrix organic light emitting diode (AMOLED) smart-phone displays and two in-plane switching (IPS) ones was visually assessed at two levels of ambient lighting conditions corresponding to indoor and outdoor applications, respectively. Naturalness, colorfulness, brightness, contrast, sharpness, and overall image quality were evaluated via psychophysical experiment by categorical judgment method using test images selected from different application categories. The experimental results show that the AMOLED displays perform better on colorfulness because of their wide color gamut, while the high pixel resolution and high peak luminance of the IPS panels help the perception of brightness, contrast, and sharpness. Further statistical analysis of ANOVA indicates that ambient lighting levels have significant influences on the attributes of brightness and contrast.

  4. Specific immunotherapy for rhinitis and asthma with a subcutaneous hypoallergenic high-dose house dust mite extract: results of a 9-month therapy.

    PubMed

    El-Qutob, David; Moreno, Francisco; Subtil-Rodríguez, Alicia

    2016-07-01

    Effectiveness of a 9-month specific immunotherapy with a subcutaneous hypoallergenic high-dose house dust mite extract to reduce allergic symptoms as perceived by patients and physicians was assessed. An observational, retrospective, multicenter study was carried out in patients diagnosed with asthma and/or rhinitis caused by house dust mites having started specific immunotherapy with Acaroid(®). Primary end point was perceived effectiveness. A total of 409 patients were included. According to physician-completed visual analogue scale, a 58.1% clinical improvement was observed. Patient-completed visual analogue scale showed a 69.8% clinical improvement. The need for unscheduled/emergency healthcare, as an indication of poor quality of life, showed a significant reduction. Our results confirm in a real-world setting the findings from randomized clinical trials of high-dose house dust mites allergoid immunotherapy with a subcutaneous hypoallergenic high-dose house dust mite extract.

  5. Smart-system of distance learning of visually impaired people based on approaches of artificial intelligence

    NASA Astrophysics Data System (ADS)

    Samigulina, Galina A.; Shayakhmetova, Assem S.

    2016-11-01

    Research objective is the creation of intellectual innovative technology and information Smart-system of distance learning for visually impaired people. The organization of the available environment for receiving quality education for visually impaired people, their social adaptation in society are important and topical issues of modern education.The proposed Smart-system of distance learning for visually impaired people can significantly improve the efficiency and quality of education of this category of people. The scientific novelty of proposed Smart-system is using intelligent and statistical methods of processing multi-dimensional data, and taking into account psycho-physiological characteristics of perception and awareness learning information by visually impaired people.

  6. High Resolution, High-Speed Photography, an Increasingly Prominent Diagnostic in Ballistic Research Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaw, L.; Muelder, S.

    1999-10-22

    High resolution, high-speed photography is becoming a prominent diagnostic in ballistic experimentation. The development of high speed cameras utilizing electro-optics and the use of lasers for illumination now provide the capability to routinely obtain high quality photographic records of ballistic style experiments. The purpose of this presentation is to review in a visual manner the progress of this technology and how it has impacted ballistic experimentation. Within the framework of development at LLNL, we look at the recent history of large format high-speed photography, and present a number of photographic records that represent the state of the art at themore » time they were made. These records are primarily from experiments involving shaped charges. We also present some examples of current photographic technology, developed within the ballistic community, that has application to hydro diagnostic experimentation at large. This paper is designed primarily as an oral-visual presentation. This written portion is to provide general background, a few examples, and a bibliography.« less

  7. Family Literacy and Global Literature: Parents as Partners in the Common Core

    ERIC Educational Resources Information Center

    Truesdell, Kim S.; del Prado Hill, Pixita

    2015-01-01

    This "Teaching Tip" will explain an initiative, Global Book Hour, that engages families in a global literature read aloud. GBH integrates social studies, the visual and performing arts, healthy eating, and vocabulary development as children travel the world through high quality global children's literature. The program is a…

  8. SILVA tree viewer: interactive web browsing of the SILVA phylogenetic guide trees.

    PubMed

    Beccati, Alan; Gerken, Jan; Quast, Christian; Yilmaz, Pelin; Glöckner, Frank Oliver

    2017-09-30

    Phylogenetic trees are an important tool to study the evolutionary relationships among organisms. The huge amount of available taxa poses difficulties in their interactive visualization. This hampers the interaction with the users to provide feedback for the further improvement of the taxonomic framework. The SILVA Tree Viewer is a web application designed for visualizing large phylogenetic trees without requiring the download of any software tool or data files. The SILVA Tree Viewer is based on Web Geographic Information Systems (Web-GIS) technology with a PostgreSQL backend. It enables zoom and pan functionalities similar to Google Maps. The SILVA Tree Viewer enables access to two phylogenetic (guide) trees provided by the SILVA database: the SSU Ref NR99 inferred from high-quality, full-length small subunit sequences, clustered at 99% sequence identity and the LSU Ref inferred from high-quality, full-length large subunit sequences. The Tree Viewer provides tree navigation, search and browse tools as well as an interactive feedback system to collect any kinds of requests ranging from taxonomy to data curation and improving the tool itself.

  9. Automated estimation of image quality for coronary computed tomographic angiography using machine learning.

    PubMed

    Nakanishi, Rine; Sankaran, Sethuraman; Grady, Leo; Malpeso, Jenifer; Yousfi, Razik; Osawa, Kazuhiro; Ceponiene, Indre; Nazarat, Negin; Rahmani, Sina; Kissel, Kendall; Jayawardena, Eranthi; Dailing, Christopher; Zarins, Christopher; Koo, Bon-Kwon; Min, James K; Taylor, Charles A; Budoff, Matthew J

    2018-03-23

    Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA). The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale. The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively. Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability. • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.

  10. The Dynamics and Neural Correlates of Audio-Visual Integration Capacity as Determined by Temporal Unpredictability, Proactive Interference, and SOA.

    PubMed

    Wilbiks, Jonathan M P; Dyson, Benjamin J

    2016-01-01

    Over 5 experiments, we challenge the idea that the capacity of audio-visual integration need be fixed at 1 item. We observe that the conditions under which audio-visual integration is most likely to exceed 1 occur when stimulus change operates at a slow rather than fast rate of presentation and when the task is of intermediate difficulty such as when low levels of proactive interference (3 rather than 8 interfering visual presentations) are combined with the temporal unpredictability of the critical frame (Experiment 2), or, high levels of proactive interference are combined with the temporal predictability of the critical frame (Experiment 4). Neural data suggest that capacity might also be determined by the quality of perceptual information entering working memory. Experiment 5 supported the proposition that audio-visual integration was at play during the previous experiments. The data are consistent with the dynamic nature usually associated with cross-modal binding, and while audio-visual integration capacity likely cannot exceed uni-modal capacity estimates, performance may be better than being able to associate only one visual stimulus with one auditory stimulus.

  11. The Dynamics and Neural Correlates of Audio-Visual Integration Capacity as Determined by Temporal Unpredictability, Proactive Interference, and SOA

    PubMed Central

    Wilbiks, Jonathan M. P.; Dyson, Benjamin J.

    2016-01-01

    Over 5 experiments, we challenge the idea that the capacity of audio-visual integration need be fixed at 1 item. We observe that the conditions under which audio-visual integration is most likely to exceed 1 occur when stimulus change operates at a slow rather than fast rate of presentation and when the task is of intermediate difficulty such as when low levels of proactive interference (3 rather than 8 interfering visual presentations) are combined with the temporal unpredictability of the critical frame (Experiment 2), or, high levels of proactive interference are combined with the temporal predictability of the critical frame (Experiment 4). Neural data suggest that capacity might also be determined by the quality of perceptual information entering working memory. Experiment 5 supported the proposition that audio-visual integration was at play during the previous experiments. The data are consistent with the dynamic nature usually associated with cross-modal binding, and while audio-visual integration capacity likely cannot exceed uni-modal capacity estimates, performance may be better than being able to associate only one visual stimulus with one auditory stimulus. PMID:27977790

  12. Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

    PubMed Central

    Kretz, Florian T. A.; Breyer, Detlev; Diakonis, Vasilios F.; Klabe, Karsten; Henke, Franziska; Auffarth, Gerd U.; Kaymak, Hakan

    2015-01-01

    Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction. PMID:26301104

  13. Collaborative volume visualization with applications to underwater acoustic signal processing

    NASA Astrophysics Data System (ADS)

    Jarvis, Susan; Shane, Richard T.

    2000-08-01

    Distributed collaborative visualization systems represent a technology whose time has come. Researchers at the Fraunhofer Center for Research in Computer Graphics have been working in the areas of collaborative environments and high-end visualization systems for several years. The medical application. TeleInVivo, is an example of a system which marries visualization and collaboration. With TeleInvivo, users can exchange and collaboratively interact with volumetric data sets in geographically distributed locations. Since examination of many physical phenomena produce data that are naturally volumetric, the visualization frameworks used by TeleInVivo have been extended for non-medical applications. The system can now be made compatible with almost any dataset that can be expressed in terms of magnitudes within a 3D grid. Coupled with advances in telecommunications, telecollaborative visualization is now possible virtually anywhere. Expert data quality assurance and analysis can occur remotely and interactively without having to send all the experts into the field. Building upon this point-to-point concept of collaborative visualization, one can envision a larger pooling of resources to form a large overview of a region of interest from contributions of numerous distributed members.

  14. Visualization of Fiber Structurein the Left and Right Ventricleof a Human Heart

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rohmer, Damien; Sitek, Arkadiusz; Gullberg, Grant T.

    2006-07-12

    The human heart is composed of a helical network of musclefibers. Anisotropic least squares filtering followed by fiber trackingtechniques were applied to Diffusion Tensor Magnetic Resonance Imaging(DTMRI) data of the excised human heart. The fiber configuration wasvisualized by using thin tubes to increase 3-dimensional visualperception of the complex structure. All visualizations were performedusing the high-quality ray-tracing software POV-Ray. The fibers are shownwithin the left and right ventricles. Both ventricles exhibit similarfiber architecture and some bundles of fibers are shown linking right andleft ventricles on the posterior region of the heart.

  15. The medium and the message: a revisionist view of image quality

    NASA Astrophysics Data System (ADS)

    Ferwerda, James A.

    2010-02-01

    In his book "Understanding Media" social theorist Marshall McLuhan declared: "The medium is the message." The thesis of this paper is that with respect to image quality, imaging system developers have taken McLuhan's dictum too much to heart. Efforts focus on improving the technical specifications of the media (e.g. dynamic range, color gamut, resolution, temporal response) with little regard for the visual messages the media will be used to communicate. We present a series of psychophysical studies that investigate the visual system's ability to "see through" the limitations of imaging media to perceive the messages (object and scene properties) the images represent. The purpose of these studies is to understand the relationships between the signal characteristics of an image and the fidelity of the visual information the image conveys. The results of these studies provide a new perspective on image quality that shows that images that may be very different in "quality", can be visually equivalent as realistic representations of objects and scenes.

  16. Quantifying the visual-sensory landscape qualities that contribute to cultural ecosystem services using social media and LiDAR

    USGS Publications Warehouse

    Van Berkel, Derek B.; Tabrizian, Payam; Dorning, Monica; Smart, Lindsey S.; Newcomb, Doug; Mehaffey, Megan; Neale, Anne; Meentemeyer, Ross K.

    2018-01-01

    Landscapes are increasingly recognized for providing valuable cultural ecosystem services with numer- ous non-material benefits by serving as places of rest, relaxation, and inspiration that ultimately improve overall mental health and physical well-being. Maintaining and enhancing these valuable benefits through targeted management and conservation measures requires understanding the spatial and tem- poral determinants of perceived landscape values. Content contributed through mobile technologies and the web are emerging globally, providing a promising data source for localizing and assessing these land- scape benefits. These georeferenced data offer rich in situ qualitative information through photos and comments that capture valued and special locations across large geographic areas. We present a novel method for mapping and modeling landscape values and perceptions that leverages viewshed analysis of georeferenced social media data. Using a high resolution LiDAR (Light Detection and Ranging) derived digital surface model, we are able to evaluate landscape characteristics associated with the visual- sensory qualities of outdoor recreationalists. Our results show the importance of historical monuments and attractions in addition to specific environmental features which are appreciated by the public. Evaluation of photo-image content highlights the opportunity of including temporally and spatially vari- able visual-sensory qualities in cultural ecosystem services (CES) evaluation like the sights, sounds and smells of wildlife and weather phenomena.

  17. Visual Saliency Detection Based on Multiscale Deep CNN Features.

    PubMed

    Guanbin Li; Yizhou Yu

    2016-11-01

    Visual saliency is a fundamental problem in both cognitive and computational sciences, including computer vision. In this paper, we discover that a high-quality visual saliency model can be learned from multiscale features extracted using deep convolutional neural networks (CNNs), which have had many successes in visual recognition tasks. For learning such saliency models, we introduce a neural network architecture, which has fully connected layers on top of CNNs responsible for feature extraction at three different scales. The penultimate layer of our neural network has been confirmed to be a discriminative high-level feature vector for saliency detection, which we call deep contrast feature. To generate a more robust feature, we integrate handcrafted low-level features with our deep contrast feature. To promote further research and evaluation of visual saliency models, we also construct a new large database of 4447 challenging images and their pixelwise saliency annotations. Experimental results demonstrate that our proposed method is capable of achieving the state-of-the-art performance on all public benchmarks, improving the F-measure by 6.12% and 10%, respectively, on the DUT-OMRON data set and our new data set (HKU-IS), and lowering the mean absolute error by 9% and 35.3%, respectively, on these two data sets.

  18. Flow visualization for investigating stator losses in a multistage axial compressor

    NASA Astrophysics Data System (ADS)

    Smith, Natalie R.; Key, Nicole L.

    2015-05-01

    The methodology and implementation of a powder-paint-based flow visualization technique along with the illuminated flow physics are presented in detail for application in a three-stage axial compressor. While flow visualization often accompanies detailed studies, the turbomachinery literature lacks a comprehensive study which both utilizes flow visualization to interrupt the flow field and explains the intricacies of execution. Lessons learned for obtaining high-quality images of surface flow patterns are discussed in this study. Fluorescent paint is used to provide clear, high-contrast pictures of the recirculation regions on shrouded vane rows. An edge-finding image processing procedure is implemented to provide a quantitative measure of vane-to-vane variability in flow separation, which is approximately 7 % of the suction surface length for Stator 1. Results include images of vane suction side corner separations from all three stages at three loading conditions. Additionally, streakline patterns obtained experimentally are compared with those calculated from computational models. Flow physics associated with vane clocking and increased rotor tip clearance and their implications to stator loss are also investigated with this flow visualization technique. With increased rotor tip clearance, the vane surface flow patterns show a shift to larger separations and more radial flow at the tip. Finally, the effects of instrumentation on the flow field are highlighted.

  19. The artificial retina for track reconstruction at the LHC crossing rate

    NASA Astrophysics Data System (ADS)

    Abba, A.; Bedeschi, F.; Citterio, M.; Caponio, F.; Cusimano, A.; Geraci, A.; Marino, P.; Morello, M. J.; Neri, N.; Punzi, G.; Piucci, A.; Ristori, L.; Spinella, F.; Stracka, S.; Tonelli, D.

    2016-04-01

    We present the results of an R&D study for a specialized processor capable of precisely reconstructing events with hundreds of charged-particle tracks in pixel and silicon strip detectors at 40 MHz, thus suitable for processing LHC events at the full crossing frequency. For this purpose we design and test a massively parallel pattern-recognition algorithm, inspired to the current understanding of the mechanisms adopted by the primary visual cortex of mammals in the early stages of visual-information processing. The detailed geometry and charged-particle's activity of a large tracking detector are simulated and used to assess the performance of the artificial retina algorithm. We find that high-quality tracking in large detectors is possible with sub-microsecond latencies when the algorithm is implemented in modern, high-speed, high-bandwidth FPGA devices.

  20. Pixel-wise deblurring imaging system based on active vision for structural health monitoring at a speed of 100 km/h

    NASA Astrophysics Data System (ADS)

    Hayakawa, Tomohiko; Moko, Yushi; Morishita, Kenta; Ishikawa, Masatoshi

    2018-04-01

    In this paper, we propose a pixel-wise deblurring imaging (PDI) system based on active vision for compensation of the blur caused by high-speed one-dimensional motion between a camera and a target. The optical axis is controlled by back-and-forth motion of a galvanometer mirror to compensate the motion. High-spatial-resolution image captured by our system in high-speed motion is useful for efficient and precise visual inspection, such as visually judging abnormal parts of a tunnel surface to prevent accidents; hence, we applied the PDI system for structural health monitoring. By mounting the system onto a vehicle in a tunnel, we confirmed significant improvement in image quality for submillimeter black-and-white stripes and real tunnel-surface cracks at a speed of 100 km/h.

  1. High resolution iridocorneal angle imaging system by axicon lens assisted gonioscopy.

    PubMed

    Perinchery, Sandeep Menon; Shinde, Anant; Fu, Chan Yiu; Jeesmond Hong, Xun Jie; Baskaran, Mani; Aung, Tin; Murukeshan, Vadakke Matham

    2016-07-29

    Direct visualization and assessment of the iridocorneal angle (ICA) region with high resolution is important for the clinical evaluation of glaucoma. However, the current clinical imaging systems for ICA do not provide sufficient structural details due to their poor resolution. The key challenges in achieving high quality ICA imaging are its location in the anterior region of the eye and the occurrence of total internal reflection due to refractive index difference between cornea and air. Here, we report an indirect axicon assisted gonioscopy imaging probe with white light illumination. The illustrated results with this probe shows significantly improved visualization of structures in the ICA including TM region, compared to the current available tools. It could reveal critical details of ICA and expected to aid management by providing information that is complementary to angle photography and gonioscopy.

  2. High resolution iridocorneal angle imaging system by axicon lens assisted gonioscopy

    PubMed Central

    Perinchery, Sandeep Menon; Shinde, Anant; Fu, Chan Yiu; Jeesmond Hong, Xun Jie; Baskaran, Mani; Aung, Tin; Murukeshan, Vadakke Matham

    2016-01-01

    Direct visualization and assessment of the iridocorneal angle (ICA) region with high resolution is important for the clinical evaluation of glaucoma. However, the current clinical imaging systems for ICA do not provide sufficient structural details due to their poor resolution. The key challenges in achieving high quality ICA imaging are its location in the anterior region of the eye and the occurrence of total internal reflection due to refractive index difference between cornea and air. Here, we report an indirect axicon assisted gonioscopy imaging probe with white light illumination. The illustrated results with this probe shows significantly improved visualization of structures in the ICA including TM region, compared to the current available tools. It could reveal critical details of ICA and expected to aid management by providing information that is complementary to angle photography and gonioscopy. PMID:27471000

  3. High resolution iridocorneal angle imaging system by axicon lens assisted gonioscopy

    NASA Astrophysics Data System (ADS)

    Perinchery, Sandeep Menon; Shinde, Anant; Fu, Chan Yiu; Jeesmond Hong, Xun Jie; Baskaran, Mani; Aung, Tin; Murukeshan, Vadakke Matham

    2016-07-01

    Direct visualization and assessment of the iridocorneal angle (ICA) region with high resolution is important for the clinical evaluation of glaucoma. However, the current clinical imaging systems for ICA do not provide sufficient structural details due to their poor resolution. The key challenges in achieving high quality ICA imaging are its location in the anterior region of the eye and the occurrence of total internal reflection due to refractive index difference between cornea and air. Here, we report an indirect axicon assisted gonioscopy imaging probe with white light illumination. The illustrated results with this probe shows significantly improved visualization of structures in the ICA including TM region, compared to the current available tools. It could reveal critical details of ICA and expected to aid management by providing information that is complementary to angle photography and gonioscopy.

  4. Computer vision for RGB-D sensors: Kinect and its applications.

    PubMed

    Shao, Ling; Han, Jungong; Xu, Dong; Shotton, Jamie

    2013-10-01

    Kinect sensor, high-resolution depth and visual (RGB) sensing has become available for widespread use as an off-the-shelf technology. This special issue is specifically dedicated to new algorithms and/or new applications based on the Kinect (or similar RGB-D) sensors. In total, we received over ninety submissions from more than twenty countries all around the world. The submissions cover a wide range of areas including object and scene classification, 3-D pose estimation, visual tracking, data fusion, human action/activity recognition, 3-D reconstruction, mobile robotics, and so on. After two rounds of review by at least two (mostly three) expert reviewers for each paper, the Guest Editors have selected twelve high-quality papers to be included in this highly popular special issue. The papers that comprise this issue are briefly summarized.

  5. Perceptual compression of magnitude-detected synthetic aperture radar imagery

    NASA Technical Reports Server (NTRS)

    Gorman, John D.; Werness, Susan A.

    1994-01-01

    A perceptually-based approach for compressing synthetic aperture radar (SAR) imagery is presented. Key components of the approach are a multiresolution wavelet transform, a bit allocation mask based on an empirical human visual system (HVS) model, and hybrid scalar/vector quantization. Specifically, wavelet shrinkage techniques are used to segregate wavelet transform coefficients into three components: local means, edges, and texture. Each of these three components is then quantized separately according to a perceptually-based bit allocation scheme. Wavelet coefficients associated with local means and edges are quantized using high-rate scalar quantization while texture information is quantized using low-rate vector quantization. The impact of the perceptually-based multiresolution compression algorithm on visual image quality, impulse response, and texture properties is assessed for fine-resolution magnitude-detected SAR imagery; excellent image quality is found at bit rates at or above 1 bpp along with graceful performance degradation at rates below 1 bpp.

  6. Framework for cognitive analysis of dynamic perfusion computed tomography with visualization of large volumetric data

    NASA Astrophysics Data System (ADS)

    Hachaj, Tomasz; Ogiela, Marek R.

    2012-10-01

    The proposed framework for cognitive analysis of perfusion computed tomography images is a fusion of image processing, pattern recognition, and image analysis procedures. The output data of the algorithm consists of: regions of perfusion abnormalities, anatomy atlas description of brain tissues, measures of perfusion parameters, and prognosis for infracted tissues. That information is superimposed onto volumetric computed tomography data and displayed to radiologists. Our rendering algorithm enables rendering large volumes on off-the-shelf hardware. This portability of rendering solution is very important because our framework can be run without using expensive dedicated hardware. The other important factors are theoretically unlimited size of rendered volume and possibility of trading of image quality for rendering speed. Such rendered, high quality visualizations may be further used for intelligent brain perfusion abnormality identification, and computer aided-diagnosis of selected types of pathologies.

  7. Vision in a phase 3 trial of natalizumab for multiple sclerosis: relation to disability and quality of life.

    PubMed

    Chahin, Salim; Balcer, Laura J; Miller, Deborah M; Zhang, Annie; Galetta, Steven L

    2015-03-01

    Low-contrast visual acuity (LCVA), a sensitive measure of visual function in multiple sclerosis (MS), demonstrated treatment effects as a secondary outcome measure in the Phase 3 trial of natalizumab, AFFIRM. In these posttrial analyses, we studied the relation of visual function to quality of life (QOL), magnetic resonance imaging (MRI) measures, and Expanded Disability Status Scale (EDSS) scores. At baseline and at 52 and 104 weeks in AFFIRM, patients underwent binocular testing of LCVA (1.25% and 2.5% contrast) and high-contrast visual acuity (HCVA). Vision-specific QOL was assessed by the Impact of Visual Impairment Scale (IVIS), whereas the SF-36 Health Survey and Visual Analog Scale were administered as generic QOL measures and the EDSS as a measure of neurologic impairment. Among QOL measures, IVIS scores showed the most significant correlations with visual dysfunction at all time points in the trial (r= -0.25 to -0.45, P < 0.0001 for LCVA and HCVA). Higher MRI T1- and T2-lesion volumes were also associated with worse vision scores at all time points (P < 0.0001). Clinically meaningful worsening (progression) of LCVA was noted in substantial proportions of patients in AFFIRM and was prevalent even among those without EDSS progression over 2 years (21.9% with LCVA progression at 2.5% contrast; 26.2% at 1.25% contrast). HCVA worsened in only 3.7% of patients without EDSS progression. Loss of visual function, particularly as measured by LCVA, was common in AFFIRM, occurring in >20% of patients. Both LCVA and HCVA scores reflect vision-specific aspects of QOL, but LCVA provides information about disability progression not entirely captured by the EDSS. Vision represents a key dimension of outcome assessment for MS and adds valuable information on disability and QOL that can be useful to clinicians.

  8. Contrasting the use of 2 vision-specific quality of life questionnaires in subjects with open-angle glaucoma.

    PubMed

    Wren, Patricia A; Musch, David C; Janz, Nancy K; Niziol, Leslie M; Guire, Kenneth E; Gillespie, Brenda W

    2009-01-01

    To compare 2 vision-specific functional status measures to each other and to clinical parameters in the Collaborative Initial Glaucoma Treatment Study (CIGTS). CIGTS participants completed the Visual Activities Questionnaire (VAQ) and the National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and were tested for visual field (VF) and visual acuity (VA). In all, 426 subjects contributed the VAQ and NEI-VFQ scores at 54 months. Pearson correlations were used to assess associations. The VAQ subscales (range, 0 to 100) that assessed light-dark adaptation (mean=66.1), glare disability (66.4), and acuity/spatial vision (67.7) indicated vision-related functions that CIGTS participants found most difficult. On the NEI-VFQ, subjects reported high levels of visual functioning, with mean >/=90 (out of 100) on the total score and in 9 of 12 subscales. General vision (mean=82.6) received the lowest subscale score. Two subscales common to both questionnaires were highly correlated: VA (r=0.68) and peripheral vision (r=0.77) (both P<0.0001). Correlations between participants' perceptions and clinical measures of visual function were in the expected direction, but weaker. Stronger associations were found between clinical measures and the NEI-VFQ than the VAQ. Better eye VF and worse eye VA had the highest number of significant correlations with subjects' perceptions of their visual function. Increasing VF loss was associated with a significant decrease in the overall and peripheral vision subscale scores from both questionnaires, and also several other subscales. CIGTS patients reported excellent visual function on both the NEI-VFQ and VAQ. These findings will help researchers interested in assessing patients' perceptions of their visual function make an informed selection when choosing between the VAQ and the NEI-VFQ.

  9. The association of visually-assessed quality of movement during jump-landing with ankle dorsiflexion range-of-motion and hip abductor muscle strength among healthy female athletes.

    PubMed

    Rabin, Alon; Einstein, Ofira; Kozol, Zvi

    2018-05-01

    To explore the association between ankle dorsiflexion (DF) range of motion (ROM), and hip abductor muscle strength, to visually-assessed quality of movement during jump-landing. Cross-sectional. Gymnasium of participating teams. 37 female volleyball players. Quality of movement in the frontal-plane, sagittal-plane, and overall (both planes) was visually rated as "good/moderate" or "poor". Weight-bearing Ankle DF ROM and hip abductor muscle strength were compared between participants with differing quality of movement. Weight-bearing DF ROM on both sides was decreased among participants with "poor" sagittal-plane quality of movement (dominant side: 50.8° versus 43.6°, P = .02; non-dominant side: 54.6° versus 45.9°, P = .01), as well as among participants with an overall "poor" quality of movement (dominant side: 51.8° versus 44.0°, P < .01; non-dominant side: 56.5° versus 45.1°, P < .01). Weight-bearing ankle DF on the non-dominant side was decreased among participants with a "poor" frontal-plane quality of movement (53.9° versus 46.0°, P = .02). No differences in hip abductor muscle strength were noted between participants with differing quality of movement. Visual assessment of jump-landing can detect differences in quality of movement that are associated with ankle DF ROM. Clinicians observing a poor quality of movement may wish to assess ankle DF ROM. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Safety and EEG data quality of concurrent high-density EEG and high-speed fMRI at 3 Tesla.

    PubMed

    Foged, Mette Thrane; Lindberg, Ulrich; Vakamudi, Kishore; Larsson, Henrik B W; Pinborg, Lars H; Kjær, Troels W; Fabricius, Martin; Svarer, Claus; Ozenne, Brice; Thomsen, Carsten; Beniczky, Sándor; Paulson, Olaf B; Posse, Stefan

    2017-01-01

    Concurrent EEG and fMRI is increasingly used to characterize the spatial-temporal dynamics of brain activity. However, most studies to date have been limited to conventional echo-planar imaging (EPI). There is considerable interest in integrating recently developed high-speed fMRI methods with high-density EEG to increase temporal resolution and sensitivity for task-based and resting state fMRI, and for detecting interictal spikes in epilepsy. In the present study using concurrent high-density EEG and recently developed high-speed fMRI methods, we investigate safety of radiofrequency (RF) related heating, the effect of EEG on cortical signal-to-noise ratio (SNR) in fMRI, and assess EEG data quality. The study compared EPI, multi-echo EPI, multi-band EPI and multi-slab echo-volumar imaging pulse sequences, using clinical 3 Tesla MR scanners from two different vendors that were equipped with 64- and 256-channel MR-compatible EEG systems, respectively, and receive only array head coils. Data were collected in 11 healthy controls (3 males, age range 18-70 years) and 13 patients with epilepsy (8 males, age range 21-67 years). Three of the healthy controls were scanned with the 256-channel EEG system, the other subjects were scanned with the 64-channel EEG system. Scalp surface temperature, SNR in occipital cortex and head movement were measured with and without the EEG cap. The degree of artifacts and the ability to identify background activity was assessed by visual analysis by a trained expert in the 64 channel EEG data (7 healthy controls, 13 patients). RF induced heating at the surface of the EEG electrodes during a 30-minute scan period with stable temperature prior to scanning did not exceed 1.0° C with either EEG system and any of the pulse sequences used in this study. There was no significant decrease in cortical SNR due to the presence of the EEG cap (p > 0.05). No significant differences in the visually analyzed EEG data quality were found between EEG recorded during high-speed fMRI and during conventional EPI (p = 0.78). Residual ballistocardiographic artifacts resulted in 58% of EEG data being rated as poor quality. This study demonstrates that high-density EEG can be safely implemented in conjunction with high-speed fMRI and that high-speed fMRI does not adversely affect EEG data quality. However, the deterioration of the EEG quality due to residual ballistocardiographic artifacts remains a significant constraint for routine clinical applications of concurrent EEG-fMRI.

  11. Dynamic power scheduling system for JPEG2000 delivery over wireless networks

    NASA Astrophysics Data System (ADS)

    Martina, Maurizio; Vacca, Fabrizio

    2003-06-01

    Third generation mobile terminals diffusion is encouraging the development of new multimedia based applications. The reliable transmission of audiovisual content will gain major interest being one of the most valuable services. Nevertheless, mobile scenario is severely power constrained: high compression ratios and refined energy management strategies are highly advisable. JPEG2000 as the source encoding stage assures excellent performance with extremely good visual quality. However the limited power budged imposes to limit the computational effort in order to save as much power as possible. Starting from an error prone environment, as the wireless one, high error-resilience features need to be employed. This paper tries to investigate the trade-off between quality and power in such a challenging environment.

  12. Method for evaluation of human induced pluripotent stem cell quality using image analysis based on the biological morphology of cells.

    PubMed

    Wakui, Takashi; Matsumoto, Tsuyoshi; Matsubara, Kenta; Kawasaki, Tomoyuki; Yamaguchi, Hiroshi; Akutsu, Hidenori

    2017-10-01

    We propose an image analysis method for quality evaluation of human pluripotent stem cells based on biologically interpretable features. It is important to maintain the undifferentiated state of induced pluripotent stem cells (iPSCs) while culturing the cells during propagation. Cell culture experts visually select good quality cells exhibiting the morphological features characteristic of undifferentiated cells. Experts have empirically determined that these features comprise prominent and abundant nucleoli, less intercellular spacing, and fewer differentiating cellular nuclei. We quantified these features based on experts' visual inspection of phase contrast images of iPSCs and found that these features are effective for evaluating iPSC quality. We then developed an iPSC quality evaluation method using an image analysis technique. The method allowed accurate classification, equivalent to visual inspection by experts, of three iPSC cell lines.

  13. Computer aided system for segmentation and visualization of microcalcifications in digital mammograms.

    PubMed

    Reljin, Branimir; Milosević, Zorica; Stojić, Tomislav; Reljin, Irini

    2009-01-01

    Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal "images" are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph.

  14. Showing the Unsayable: Participatory Visual Approaches and the Constitution of 'Patient Experience' in Healthcare Quality Improvement.

    PubMed

    Papoulias, Constantina

    2018-06-01

    This article considers the strengths and potential contributions of participatory visual methods for healthcare quality improvement research. It argues that such approaches may enable us to expand our understanding of 'patient experience' and of its potential for generating new knowledge for health systems. In particular, they may open up dimensions of people's engagement with services and treatments which exceed both the declarative nature of responses to questionnaires and the narrative sequencing of self reports gathered through qualitative interviewing. I will suggest that working with such methods may necessitate a more reflexive approach to the constitution of evidence in quality improvement work. To this end, the article will first consider the emerging rationale for the use of visual participatory methods in improvement before outlining the implications of two related approaches-photo-elicitation and PhotoVoice-for the constitution of 'experience'. It will then move to a participatory model for healthcare improvement work, Experience Based Co-Design (EBCD). It will argue that EBCD exemplifies both the strengths and the limitations of adequating visual participatory approaches to quality improvement ends. The article will conclude with a critical reflection on a small photographic study, in which the author participated, and which sought to harness service user perspectives for the design of psychiatric facilities, as a way of considering the potential contribution of visual participatory methods for quality improvement.

  15. Power Grid Maintenance Scheduling Intelligence Arrangement Supporting System Based on Power Flow Forecasting

    NASA Astrophysics Data System (ADS)

    Xie, Chang; Wen, Jing; Liu, Wenying; Wang, Jiaming

    With the development of intelligent dispatching, the intelligence level of network control center full-service urgent need to raise. As an important daily work of network control center, the application of maintenance scheduling intelligent arrangement to achieve high-quality and safety operation of power grid is very important. By analyzing the shortages of the traditional maintenance scheduling software, this paper designs a power grid maintenance scheduling intelligence arrangement supporting system based on power flow forecasting, which uses the advanced technologies in maintenance scheduling, such as artificial intelligence, online security checking, intelligent visualization techniques. It implements the online security checking of maintenance scheduling based on power flow forecasting and power flow adjusting based on visualization, in order to make the maintenance scheduling arrangement moreintelligent and visual.

  16. Argo workstation: a key component of operational oceanography

    NASA Astrophysics Data System (ADS)

    Dong, Mingmei; Xu, Shanshan; Miao, Qingsheng; Yue, Xinyang; Lu, Jiawei; Yang, Yang

    2018-02-01

    Operational oceanography requires the quantity, quality, and availability of data set and the timeliness and effectiveness of data products. Without steady and strong operational system supporting, operational oceanography will never be proceeded far. In this paper we describe an integrated platform named Argo Workstation. It operates as a data processing and management system, capable of data collection, automatic data quality control, visualized data check, statistical data search and data service. After it is set up, Argo workstation provides global high quality Argo data to users every day timely and effectively. It has not only played a key role in operational oceanography but also set up an example for operational system.

  17. Vision-related quality of life in patients with chronic central serous chorioretinopathy.

    PubMed

    Türkcü, Fatih Mehmet; Şahin, Alparslan; Bez, Yasin; Yüksel, Harun; Cinar, Yasin; Kürşat Cingü, Abdullah; Çaça, İhsan

    2015-07-01

    To evaluate vision-related quality of life in patients with chronic central serous chorioretinopathy (CSCR). Prospective, cross-sectional study. The interviewer-administered National Eye Institute visual function questionnaire (NEI-VFQ-25) was used in 30 adult consecutive patients with chronic CSCR patients. The controls were 30 gender- and age-matched people with normal visual function who came from the same socioeconomic and educational background as the participants. Patients with CSCR had statistically significant lower scores than controls for all the subscales, except for general health. In the study group, all subscale scores of vision-related quality of life, except general health, showed statistically significant negative correlations with the visual acuity. People with CSCR have worse vision-related quality of life than people without the condition.

  18. Health-related quality of life of cataract patients: cross-cultural comparisons of utility and psychometric measures.

    PubMed

    Lee, Jae Eun; Fos, Peter J; Zuniga, Miguel A; Kastl, Peter R; Sung, Jung Hye

    2003-07-01

    This study was conducted to assess the presence and/or absence of cross-cultural differences or similarities between Korean and United States cataract patients. A systematic assessment was performed using utility and psychometric measures in the study population. A cross-sectional study design was used to examine the comparison of preoperative outcomes measures in cataract patients in Korea and the United States. Study subjects were selected using non-probabilistic methods and included 132 patients scheduled for cataract surgery in one eye. Subjects were adult cataract patients at Samsung and Kunyang General Hospital in Seoul, Korea, and Tulane University Hospital and Clinics in New Orleans, Louisiana. Preoperative utility was assessed using the verbal rating scale and standard reference gamble techniques. Current preoperative health status was assessed using the SF-36 and VF-14 surveys. Current preoperative Snellen visual acuity was used as a clinical measure of vision status. Korean patients were more likely to be younger (p = 0.001), less educated (p = 0.001), and to have worse Snellen visual acuity (p = 0.002) than United States patients. Multivariate analysis of variance (MANOVA) revealed that in contrast to Korean patients, United States patients were assessed to have higher scoring in general health, vitality, VF-14, and verbal rating for visual health. This higher scoring trend persisted after controlling for age, gender, education and Snellen visual acuity. The difference in health-related quality of life (HRQOL) between the two countries was quite clear, especially in the older age and highly educated group. Subjects in Korea and the United States were significantly different in quality of life, functional status and clinical outcomes. Subjects in the United States had more favorable health outcomes than those in Korea. These differences may be caused by multiple factors, including country-specific differences in economic status, health care system, cultural value system, and health policy. Cross-cultural differences should be considered when making international comparisons of quality of life.

  19. Comprehensive model for predicting perceptual image quality of smart mobile devices.

    PubMed

    Gong, Rui; Xu, Haisong; Luo, M R; Li, Haifeng

    2015-01-01

    An image quality model for smart mobile devices was proposed based on visual assessments of several image quality attributes. A series of psychophysical experiments were carried out on two kinds of smart mobile devices, i.e., smart phones and tablet computers, in which naturalness, colorfulness, brightness, contrast, sharpness, clearness, and overall image quality were visually evaluated under three lighting environments via categorical judgment method for various application types of test images. On the basis of Pearson correlation coefficients and factor analysis, the overall image quality could first be predicted by its two constituent attributes with multiple linear regression functions for different types of images, respectively, and then the mathematical expressions were built to link the constituent image quality attributes with the physical parameters of smart mobile devices and image appearance factors. The procedure and algorithms were applicable to various smart mobile devices, different lighting conditions, and multiple types of images, and performance was verified by the visual data.

  20. Anti-vascular endothelial growth factor for diabetic macular oedema.

    PubMed

    Virgili, Gianni; Parravano, Mariacristina; Menchini, Francesca; Evans, Jennifer R

    2014-10-24

    Diabetic macular oedema (DMO) is a common complication of diabetic retinopathy. Although grid or focal laser photocoagulation has been shown to reduce the risk of visual loss in DMO, or clinically significant macular oedema (CSMO), vision is rarely improved. Antiangiogenic therapy with anti-vascular endothelial growth factor (anti-VEGF) modalities is used to try to improve vision in people with DMO. To investigate the effects in preserving and improving vision and acceptability, including the safety, compliance with therapy and quality of life, of antiangiogenic therapy with anti-VEGF modalities for the treatment of DMO. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 3), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to April 2014), EMBASE (January 1980 to April 2014), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to April 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 28 April 2014. We included randomised controlled trials (RCTs) comparing any antiangiogenic drugs with an anti-VEGF mechanism of action versus another treatment, sham treatment or no treatment in people with DMO. We used standard methodological procedures expected by The Cochrane Collaboration. The risk ratios (RR) for visual loss and visual gain of three or more lines of logMAR visual acuity were estimated at one year of follow-up (plus or minus six months) after treatment initiation. Eighteen studies provided data on four comparisons of interest in this review. Participants in the trials had central DMO and moderate vision loss.Compared with grid laser photocoagulation, people treated with antiangiogenic therapy were more likely to gain 3 or more lines of vision at one year (RR 3.6, 95% confidence interval (CI) 2.7 to 4.8, 10 studies, 1333 cases, high quality evidence) and less likely to lose 3 or more lines of vision (RR 0.11, 95% CI 0.05 to 0.24, 7 studies, 1086 cases, high quality evidence). In meta-analyses, no significant subgroup difference was demonstrated between bevacizumab, ranibizumab and aflibercept for the two primary outcomes, but there was little power to detect a difference. The quality of the evidence was judged to be high, because the effect was large, precisely measured and did not vary across studies, although some studies were at high or unclear risk of bias for one or more domains. Regarding absolute benefit, we estimated that 8 out of 100 participants with DMO may gain 3 or more lines of visual acuity using photocoagulation whereas 28 would do so with antiangiogenic therapy, meaning that 100 participants need to be treated with antiangiogenic therapy to allow 20 more people (95% CI 13 to 29) to markedly improve their vision after one year. People treated with anti-VEGF on average had 1.6 lines better vision (95% CI 1.4 to 1.8) after one year compared to laser photocoagulation (9 studies, 1292 cases, high quality evidence). To achieve this result, seven to nine injections were delivered in the first year and three or four in the second, in larger studies adopting either as needed regimens with monthly monitoring or fixed regimens.In other analyses antiangiogenic therapy was more effective than sham (3 studies on 497 analysed participants, high quality evidence) and ranibizumab associated with laser was more effective than laser alone (4 studies on 919 participants, high quality evidence).Ocular severe adverse events, such as endophthalmitis, were rare in the included studies. Meta-analyses conducted for all antiangiogenic drugs compared with either sham or photocoagulation did not show a significant difference regarding serious systemic adverse events (15 studies, 441 events in 2985 participants, RR 0.98, 95% CI 0.83 to 1.17), arterial thromboembolic events (14 studies, 129 events in 3034 participants, RR 0.89, 95% CI 0.63 to 1.25) and overall mortality (63 events in 3562 participants, RR 0.88, 95% CI 0.52 to 1.47). We judged the quality of the evidence on adverse effects as moderate due to partial reporting of safety data and the exclusion of participants with previous cardiovascular events in some studies. There is high quality evidence that antiangiogenic drugs provide a benefit compared to current therapeutic options for DMO, that is grid laser photocoagulation, in clinical trial populations at one or two years. Future research should investigate differences between drugs, effectiveness under real-world monitoring and treatment conditions, and safety in high-risk populations, particularly regarding cardiovascular risk.

  1. Quality of Life and Mental State After Sight Restoration by Corneal Transplantation.

    PubMed

    Drzyzga, Karolina; Krupka-Matuszczyk, Irena; Drzyzga, Łukasz; Mrukwa-Kominek, Ewa; Kucia, Krzysztof

    2016-01-01

    Quality of life has frequently been reported to improve after corneal transplantation. However, mental status before and after surgery has until now been less well investigated. The aim of this study was to investigate quality of life and mental status before and after corneal transplantation including postoperative immunosuppression and visual acuity. A total of 45 patients were assessed before, and 3 weeks and 4 months after transplantation using the following questionnaires: Visual Function Questionnaire, Beck Depression Inventory, and Hamilton Anxiety Rating Scale. Assessment included a visual acuity test using the logMAR chart, and recognition of the role of postoperative immunosuppression. Finally, patients were asked if they would be willing to have the surgery again. In the candidates for surgery, quality of life was reduced, and symptoms of depression and anxiety were present. Corneal transplantation improved their quality of life and reduced symptoms of depression and anxiety. Changes in quality of life and in mental state were associated with a change in visual acuity in the grafted eye. Higher doses of prednisone were associated with a worse quality of life and with more severe symptoms of depression and anxiety after transplantation. Further, 82.5% of patients would have the surgery again. Assessment for psychiatric symptoms should be considered in individuals facing corneal surgery. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  2. A new image representation for compact and secure communication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prasad, Lakshman; Skourikhine, A. N.

    In many areas of nuclear materials management there is a need for communication, archival, and retrieval of annotated image data between heterogeneous platforms and devices to effectively implement safety, security, and safeguards of nuclear materials. Current image formats such as JPEG are not ideally suited in such scenarios as they are not scalable to different viewing formats, and do not provide a high-level representation of images that facilitate automatic object/change detection or annotation. The new Scalable Vector Graphics (SVG) open standard for representing graphical information, recommended by the World Wide Web Consortium (W3C) is designed to address issues of imagemore » scalability, portability, and annotation. However, until now there has been no viable technology to efficiently field images of high visual quality under this standard. Recently, LANL has developed a vectorized image representation that is compatible with the SVG standard and preserves visual quality. This is based on a new geometric framework for characterizing complex features in real-world imagery that incorporates perceptual principles of processing visual information known from cognitive psychology and vision science, to obtain a polygonal image representation of high fidelity. This representation can take advantage of all textual compression and encryption routines unavailable to other image formats. Moreover, this vectorized image representation can be exploited to facilitate automated object recognition that can reduce time required for data review. The objects/features of interest in these vectorized images can be annotated via animated graphics to facilitate quick and easy display and comprehension of processed image content.« less

  3. HeatmapGenerator: high performance RNAseq and microarray visualization software suite to examine differential gene expression levels using an R and C++ hybrid computational pipeline.

    PubMed

    Khomtchouk, Bohdan B; Van Booven, Derek J; Wahlestedt, Claes

    2014-01-01

    The graphical visualization of gene expression data using heatmaps has become an integral component of modern-day medical research. Heatmaps are used extensively to plot quantitative differences in gene expression levels, such as those measured with RNAseq and microarray experiments, to provide qualitative large-scale views of the transcriptonomic landscape. Creating high-quality heatmaps is a computationally intensive task, often requiring considerable programming experience, particularly for customizing features to a specific dataset at hand. Software to create publication-quality heatmaps is developed with the R programming language, C++ programming language, and OpenGL application programming interface (API) to create industry-grade high performance graphics. We create a graphical user interface (GUI) software package called HeatmapGenerator for Windows OS and Mac OS X as an intuitive, user-friendly alternative to researchers with minimal prior coding experience to allow them to create publication-quality heatmaps using R graphics without sacrificing their desired level of customization. The simplicity of HeatmapGenerator is that it only requires the user to upload a preformatted input file and download the publicly available R software language, among a few other operating system-specific requirements. Advanced features such as color, text labels, scaling, legend construction, and even database storage can be easily customized with no prior programming knowledge. We provide an intuitive and user-friendly software package, HeatmapGenerator, to create high-quality, customizable heatmaps generated using the high-resolution color graphics capabilities of R. The software is available for Microsoft Windows and Apple Mac OS X. HeatmapGenerator is released under the GNU General Public License and publicly available at: http://sourceforge.net/projects/heatmapgenerator/. The Mac OS X direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_MAC_OSX.tar.gz/download. The Windows OS direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_WINDOWS.zip/download.

  4. Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens.

    PubMed

    Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam

    2017-12-01

    To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Femtosecond laser-assisted cataract surgeries reported to the European Registry of Quality Outcomes for Cataract and Refractive Surgery: Baseline characteristics, surgical procedure, and outcomes.

    PubMed

    Lundström, Mats; Dickman, Mor; Henry, Ype; Manning, Sonia; Rosen, Paul; Tassignon, Marie-José; Young, David; Stenevi, Ulf

    2017-12-01

    To describe a large cohort of femtosecond laser-assisted cataract surgeries in terms of baseline characteristics and the related outcomes. Eighteen cataract surgery clinics in 9 European countries and Australia. Prospective multicenter case series. Data on consecutive eyes having femtosecond laser-assisted cataract surgery in the participating clinics were entered in the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO). A trained registry manager in each clinic was responsible for valid reporting to the EUREQUO. Demographics, preoperative corrected distance visual acuity (CDVA), risk factors, type of surgery, type of intraocular lens, visual outcomes, refractive outcomes, and complications were reported. Complete data were available for 3379 cases. The mean age was 64.4 years ± 10.9 (SD) and 57.8% (95% confidence interval [CI], 56.1-59.5) of the patients were women. A surgical complication was reported in 2.9% of all cases (95% CI, 2.4-3.5). The mean postoperative CDVA was 0.04 ± 0.15. logarithm of the minimum angle of resolution. A biometry prediction error (spherical equivalent) was within ±0.5 diopter in 71.8% (95% CI, 70.3-73.3) of all surgeries. Postoperative complications were reported in 3.3% (95% CI, 2.7-4.0). Patients with good preoperative CDVA had the best visual and refractive outcomes; patients with poor preoperative visual acuity had poorer outcomes. The visual and refractive outcomes of femtosecond laser-assisted cataract surgery were favorable compared with manual phacoemulsification. The outcomes were highly influenced by the preoperative visual acuity, but all preoperative CDVA groups had acceptable outcomes. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Incidence of chilling injury in fresh-cut 'Kent' mangoes

    USDA-ARS?s Scientific Manuscript database

    The preferred storage temperature for fresh-cut fruits in terms of visual quality retention is around 5 °C, which is considered to be a chilling temperature for chilling sensitive tropical fruits like mango (Mangifera indica L.). Changes in visual and compositional quality factors, aroma volatile pr...

  7. Perception of CPR quality: Influence of CPR feedback, Just-in-Time CPR training and provider role.

    PubMed

    Cheng, Adam; Overly, Frank; Kessler, David; Nadkarni, Vinay M; Lin, Yiqun; Doan, Quynh; Duff, Jonathan P; Tofil, Nancy M; Bhanji, Farhan; Adler, Mark; Charnovich, Alex; Hunt, Elizabeth A; Brown, Linda L

    2015-02-01

    Many healthcare providers rely on visual perception to guide cardiopulmonary resuscitation (CPR), but little is known about the accuracy of provider perceptions of CPR quality. We aimed to describe the difference between perceived versus measured CPR quality, and to determine the impact of provider role, real-time visual CPR feedback and Just-in-Time (JIT) CPR training on provider perceptions. We conducted secondary analyses of data collected from a prospective, multicenter, randomized trial of 324 healthcare providers who participated in a simulated cardiac arrest scenario between July 2012 and April 2014. Participants were randomized to one of four permutations of: JIT CPR training and real-time visual CPR feedback. We calculated the difference between perceived and measured quality of CPR and reported the proportion of subjects accurately estimating the quality of CPR within each study arm. Participants overestimated achieving adequate chest compression depth (mean difference range: 16.1-60.6%) and rate (range: 0.2-51%), and underestimated chest compression fraction (0.2-2.9%) across all arms. Compared to no intervention, the use of real-time feedback and JIT CPR training (alone or in combination) improved perception of depth (p<0.001). Accurate estimation of CPR quality was poor for chest compression depth (0-13%), rate (5-46%) and chest compression fraction (60-63%). Perception of depth is more accurate in CPR providers versus team leaders (27.8% vs. 7.4%; p=0.043) when using real-time feedback. Healthcare providers' visual perception of CPR quality is poor. Perceptions of CPR depth are improved by using real-time visual feedback and with prior JIT CPR training. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.

    PubMed

    Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina

    2004-10-01

    We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.

  9. A Network and Visual Quality Aware N-Screen Content Recommender System Using Joint Matrix Factorization

    PubMed Central

    Ullah, Farman; Sarwar, Ghulam; Lee, Sungchang

    2014-01-01

    We propose a network and visual quality aware N-Screen content recommender system. N-Screen provides more ways than ever before to access multimedia content through multiple devices and heterogeneous access networks. The heterogeneity of devices and access networks present new questions of QoS (quality of service) in the realm of user experience with content. We propose, a recommender system that ensures a better visual quality on user's N-screen devices and the efficient utilization of available access network bandwidth with user preferences. The proposed system estimates the available bandwidth and visual quality on users N-Screen devices and integrates it with users preferences and contents genre information to personalize his N-Screen content. The objective is to recommend content that the user's N-Screen device and access network are capable of displaying and streaming with the user preferences that have not been supported in existing systems. Furthermore, we suggest a joint matrix factorization approach to jointly factorize the users rating matrix with the users N-Screen device similarity and program genres similarity. Finally, the experimental results show that we also enhance the prediction and recommendation accuracy, sparsity, and cold start issues. PMID:24982999

  10. Scientific Visualization and Simulation for Multi-dimensional Marine Environment Data

    NASA Astrophysics Data System (ADS)

    Su, T.; Liu, H.; Wang, W.; Song, Z.; Jia, Z.

    2017-12-01

    As higher attention on the ocean and rapid development of marine detection, there are increasingly demands for realistic simulation and interactive visualization of marine environment in real time. Based on advanced technology such as GPU rendering, CUDA parallel computing and rapid grid oriented strategy, a series of efficient and high-quality visualization methods, which can deal with large-scale and multi-dimensional marine data in different environmental circumstances, has been proposed in this paper. Firstly, a high-quality seawater simulation is realized by FFT algorithm, bump mapping and texture animation technology. Secondly, large-scale multi-dimensional marine hydrological environmental data is virtualized by 3d interactive technologies and volume rendering techniques. Thirdly, seabed terrain data is simulated with improved Delaunay algorithm, surface reconstruction algorithm, dynamic LOD algorithm and GPU programming techniques. Fourthly, seamless modelling in real time for both ocean and land based on digital globe is achieved by the WebGL technique to meet the requirement of web-based application. The experiments suggest that these methods can not only have a satisfying marine environment simulation effect, but also meet the rendering requirements of global multi-dimension marine data. Additionally, a simulation system for underwater oil spill is established by OSG 3D-rendering engine. It is integrated with the marine visualization method mentioned above, which shows movement processes, physical parameters, current velocity and direction for different types of deep water oil spill particle (oil spill particles, hydrates particles, gas particles, etc.) dynamically and simultaneously in multi-dimension. With such application, valuable reference and decision-making information can be provided for understanding the progress of oil spill in deep water, which is helpful for ocean disaster forecasting, warning and emergency response.

  11. Assessment of three-dimensional high-definition visualization technology to perform microvascular anastomosis.

    PubMed

    Wong, Alex K; Davis, Gabrielle B; Nguyen, T JoAnna; Hui, Kenneth J W S; Hwang, Brian H; Chan, Linda S; Zhou, Zhao; Schooler, Wesley G; Chandrasekhar, Bala S; Urata, Mark M

    2014-07-01

    Traditional visualization techniques in microsurgery require strict positioning in order to maintain the field of visualization. However, static posturing over time may lead to musculoskeletal strain and injury. Three-dimensional high-definition (3DHD) visualization technology may be a useful adjunct to limiting static posturing and improving ergonomics in microsurgery. In this study, we aimed to investigate the benefits of using the 3DHD technology over traditional techniques. A total of 14 volunteers consisting of novice and experienced microsurgeons performed femoral anastomoses on male Sprague-Dawley retired breeder rats using traditional techniques as well as the 3DHD technology and compared the two techniques. Participants subsequently completed a questionnaire regarding their preference in terms of operational parameters, ergonomics, overall quality, and educational benefits. Efficiency was also evaluated by mean times to complete the anastomosis with each technique. A total of 27 anastomoses were performed, 14 of 14 using the traditional microscope and 13 of 14 using the 3DHD technology. Preference toward the traditional modality was noted with respect to the parameters of precision, field adjustments, zoom and focus, depth perception, and overall quality. The 3DHD technique was preferred for improved stamina and less back and eye strain. Participants believed that the 3DHD technique was the better method for learning microsurgery. Longer mean time of anastomosis completion was noted in participants utilizing the 3DHD technique. The 3DHD technology may prove to be valuable in improving proper ergonomics in microsurgery. In addition, it may be useful in medical education when applied to the learning of new microsurgical skills. More studies are warranted to determine its efficacy and safety in a clinical setting. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Parts-based stereoscopic image assessment by learning binocular manifold color visual properties

    NASA Astrophysics Data System (ADS)

    Xu, Haiyong; Yu, Mei; Luo, Ting; Zhang, Yun; Jiang, Gangyi

    2016-11-01

    Existing stereoscopic image quality assessment (SIQA) methods are mostly based on the luminance information, in which color information is not sufficiently considered. Actually, color is part of the important factors that affect human visual perception, and nonnegative matrix factorization (NMF) and manifold learning are in line with human visual perception. We propose an SIQA method based on learning binocular manifold color visual properties. To be more specific, in the training phase, a feature detector is created based on NMF with manifold regularization by considering color information, which not only allows parts-based manifold representation of an image, but also manifests localized color visual properties. In the quality estimation phase, visually important regions are selected by considering different human visual attention, and feature vectors are extracted by using the feature detector. Then the feature similarity index is calculated and the parts-based manifold color feature energy (PMCFE) for each view is defined based on the color feature vectors. The final quality score is obtained by considering a binocular combination based on PMCFE. The experimental results on LIVE I and LIVE Π 3-D IQA databases demonstrate that the proposed method can achieve much higher consistency with subjective evaluations than the state-of-the-art SIQA methods.

  13. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  14. Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo

    2013-04-01

    To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.

  15. Efficacy of vision restoration therapy after optic neuritis (VISION study): study protocol for a randomized controlled trial.

    PubMed

    Schinzel, Johann; Schwarzlose, Lina; Dietze, Holger; Bartusch, Karolina; Weiss, Susanne; Ohlraun, Stephanie; Paul, Friedemann; Dörr, Jan

    2012-06-28

    Optic neuritis is a frequent manifestation of multiple sclerosis. Visual deficits range from a minor impairment of visual functions through to complete loss of vision. Although many patients recover almost completely, roughly 35% of patients remain visually impaired for years, and therapeutic options for those patients hardly exist. Vision restoration therapy is a software-based visual training program that has been shown to improve visual deficits after pre- and postchiasmatic injury. The aim of this pilot study is to evaluate whether residual visual deficits after past or recent optic neuritis can be reduced by means of vision restoration therapy. A randomized, controlled, patient- and observer-blinded clinical pilot study (VISION study) was designed to evaluate the efficacy of vision restoration therapy in optic neuritis patients. Eighty patients with a residual visual deficit after optic neuritis (visual acuity ≤0.7 and/or scotoma) will be stratified according to the time of optic neuritis onset (manifestation more than 12 months ago (40 patients, fixed deficit) versus manifestation 2 to 6 months ago (40 patients, recent optic neuritis)), and randomized into vision restoration therapy arm or saccadic training arm (control intervention). Patients will be instructed to complete a computer-based visual training for approximately 30 minutes each day for a period of 6 months. Patients and evaluators remain blinded to the treatment allocation throughout the study. All endpoints will be analyzed and P-values < 0.05 will be considered statistically significant. The primary outcome parameter will be the expansion of the visual field after 3 and 6 months of treatment as determined by static visual field perimetry and high resolution perimetry. Secondary outcome variables will include visual acuity at both low and high contrast, glare contrast sensitivity, visually evoked potentials, optical coherence tomography and other functional tests of the visual system, alertness, health-related quality of life, fatigue, and depression. If vision restoration therapy is shown to improve visual function after optic neuritis, this method might be a first therapeutic option for patients with incomplete recovery from optic neuritis. NCT01274702.

  16. Can state-of-the-art HVS-based objective image quality criteria be used for image reconstruction techniques based on ROI analysis?

    NASA Astrophysics Data System (ADS)

    Dostal, P.; Krasula, L.; Klima, M.

    2012-06-01

    Various image processing techniques in multimedia technology are optimized using visual attention feature of the human visual system. Spatial non-uniformity causes that different locations in an image are of different importance in terms of perception of the image. In other words, the perceived image quality depends mainly on the quality of important locations known as regions of interest. The performance of such techniques is measured by subjective evaluation or objective image quality criteria. Many state-of-the-art objective metrics are based on HVS properties; SSIM, MS-SSIM based on image structural information, VIF based on the information that human brain can ideally gain from the reference image or FSIM utilizing the low-level features to assign the different importance to each location in the image. But still none of these objective metrics utilize the analysis of regions of interest. We solve the question if these objective metrics can be used for effective evaluation of images reconstructed by processing techniques based on ROI analysis utilizing high-level features. In this paper authors show that the state-of-the-art objective metrics do not correlate well with subjective evaluation while the demosaicing based on ROI analysis is used for reconstruction. The ROI were computed from "ground truth" visual attention data. The algorithm combining two known demosaicing techniques on the basis of ROI location is proposed to reconstruct the ROI in fine quality while the rest of image is reconstructed with low quality. The color image reconstructed by this ROI approach was compared with selected demosaicing techniques by objective criteria and subjective testing. The qualitative comparison of the objective and subjective results indicates that the state-of-the-art objective metrics are still not suitable for evaluation image processing techniques based on ROI analysis and new criteria is demanded.

  17. Electrical Capacitance Tomography Measurement of the Migration of Ice Frontal Surface in Freezing Soil

    NASA Astrophysics Data System (ADS)

    Liu, J.; Suo, X. M.; Zhou, S. S.; Meng, S. Q.; Chen, S. S.; Mu, H. P.

    2016-12-01

    The tracking of the migration of ice frontal surface is crucial for the understanding of the underlying physical mechanisms in freezing soil. Owing to the distinct advantages, including non-invasive sensing, high safety, low cost and high data acquisition speed, the electrical capacitance tomography (ECT) is considered to be a promising visualization measurement method. In this paper, the ECT method is used to visualize the migration of ice frontal surface in freezing soil. With the main motivation of the improvement of imaging quality, a loss function with multiple regularizers that incorporate the prior formation related to the imaging objects is proposed to cast the ECT image reconstruction task into an optimization problem. An iteration scheme that integrates the superiority of the split Bregman iteration (SBI) method is developed for searching for the optimal solution of the proposed loss function. An unclosed electrodes sensor is designed for satisfying the requirements of practical measurements. An experimental system of one dimensional freezing in frozen soil is constructed, and the ice frontal surface migration in the freezing process of the wet soil sample containing five percent of moisture is measured. The visualization measurement results validate the feasibility and effectiveness of the ECT visualization method

  18. Quality issues in blue noise halftoning

    NASA Astrophysics Data System (ADS)

    Yu, Qing; Parker, Kevin J.

    1998-01-01

    The blue noise mask (BNM) is a halftone screen that produces unstructured visually pleasing dot patterns. The BNM combines the blue-noise characteristics of error diffusion and the simplicity of ordered dither. A BNM is constructed by designing a set of interdependent binary patterns for individual gray levels. In this paper, we investigate the quality issues in blue-noise binary pattern design and mask generation as well as in application to color reproduction. Using a global filtering technique and a local 'force' process for rearranging black and white pixels, we are able to generate a series of binary patterns, all representing a certain gray level, ranging from white-noise pattern to highly structured pattern. The quality of these individual patterns are studied in terms of low-frequency structure and graininess. Typically, the low-frequency structure (LF) is identified with a measurement of the energy around dc in the spatial frequency domain, while the graininess is quantified by a measurement of the average minimum distance (AMD) between minority dots as well as the kurtosis of the local kurtosis distribution (KLK) for minority pixels of the binary pattern. A set of partial BNMs are generated by using the different patterns as unique starting 'seeds.' In this way, we are able to study the quality of binary patterns over a range of gray levels. We observe that the optimality of a binary pattern for mask generation is related to its own quality mertirc values as well as the transition smoothness of those quality metric values over neighboring levels. Several schemes have been developed to apply blue-noise halftoning to color reproduction. Different schemes generate halftone patterns with different textures. In a previous paper, a human visual system (HVS) model was used to study the color halftone quality in terms of luminance and chrominance error in CIELAB color space. In this paper, a new series of psycho-visual experiments address the 'preferred' color rendering among four different blue noise halftoning schemes. The experimental results will be interpreted with respect to the proposed halftone quality metrics.

  19. SU-F-J-72: A Clinical Usable Integrated Contouring Quality Evaluation Software for Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, S; Dolly, S; Cai, B

    Purpose: To introduce the Auto Contour Evaluation (ACE) software, which is the clinical usable, user friendly, efficient and all-in-one toolbox for automatically identify common contouring errors in radiotherapy treatment planning using supervised machine learning techniques. Methods: ACE is developed with C# using Microsoft .Net framework and Windows Presentation Foundation (WPF) for elegant GUI design and smooth GUI transition animations through the integration of graphics engines and high dots per inch (DPI) settings on modern high resolution monitors. The industrial standard software design pattern, Model-View-ViewModel (MVVM) pattern, is chosen to be the major architecture of ACE for neat coding structure, deepmore » modularization, easy maintainability and seamless communication with other clinical software. ACE consists of 1) a patient data importing module integrated with clinical patient database server, 2) a 2D DICOM image and RT structure simultaneously displaying module, 3) a 3D RT structure visualization module using Visualization Toolkit or VTK library and 4) a contour evaluation module using supervised pattern recognition algorithms to detect contouring errors and display detection results. ACE relies on supervised learning algorithms to handle all image processing and data processing jobs. Implementations of related algorithms are powered by Accord.Net scientific computing library for better efficiency and effectiveness. Results: ACE can take patient’s CT images and RT structures from commercial treatment planning software via direct user input or from patients’ database. All functionalities including 2D and 3D image visualization and RT contours error detection have been demonstrated with real clinical patient cases. Conclusion: ACE implements supervised learning algorithms and combines image processing and graphical visualization modules for RT contours verification. ACE has great potential for automated radiotherapy contouring quality verification. Structured with MVVM pattern, it is highly maintainable and extensible, and support smooth connections with other clinical software tools.« less

  20. Scalable Multi-Platform Distribution of Spatial 3d Contents

    NASA Astrophysics Data System (ADS)

    Klimke, J.; Hagedorn, B.; Döllner, J.

    2013-09-01

    Virtual 3D city models provide powerful user interfaces for communication of 2D and 3D geoinformation. Providing high quality visualization of massive 3D geoinformation in a scalable, fast, and cost efficient manner is still a challenging task. Especially for mobile and web-based system environments, software and hardware configurations of target systems differ significantly. This makes it hard to provide fast, visually appealing renderings of 3D data throughout a variety of platforms and devices. Current mobile or web-based solutions for 3D visualization usually require raw 3D scene data such as triangle meshes together with textures delivered from server to client, what makes them strongly limited in terms of size and complexity of the models they can handle. In this paper, we introduce a new approach for provisioning of massive, virtual 3D city models on different platforms namely web browsers, smartphones or tablets, by means of an interactive map assembled from artificial oblique image tiles. The key concept is to synthesize such images of a virtual 3D city model by a 3D rendering service in a preprocessing step. This service encapsulates model handling and 3D rendering techniques for high quality visualization of massive 3D models. By generating image tiles using this service, the 3D rendering process is shifted from the client side, which provides major advantages: (a) The complexity of the 3D city model data is decoupled from data transfer complexity (b) the implementation of client applications is simplified significantly as 3D rendering is encapsulated on server side (c) 3D city models can be easily deployed for and used by a large number of concurrent users, leading to a high degree of scalability of the overall approach. All core 3D rendering techniques are performed on a dedicated 3D rendering server, and thin-client applications can be compactly implemented for various devices and platforms.

  1. Depth image enhancement using perceptual texture priors

    NASA Astrophysics Data System (ADS)

    Bang, Duhyeon; Shim, Hyunjung

    2015-03-01

    A depth camera is widely used in various applications because it provides a depth image of the scene in real time. However, due to the limited power consumption, the depth camera presents severe noises, incapable of providing the high quality 3D data. Although the smoothness prior is often employed to subside the depth noise, it discards the geometric details so to degrade the distance resolution and hinder achieving the realism in 3D contents. In this paper, we propose a perceptual-based depth image enhancement technique that automatically recovers the depth details of various textures, using a statistical framework inspired by human mechanism of perceiving surface details by texture priors. We construct the database composed of the high quality normals. Based on the recent studies in human visual perception (HVP), we select the pattern density as a primary feature to classify textures. Upon the classification results, we match and substitute the noisy input normals with high quality normals in the database. As a result, our method provides the high quality depth image preserving the surface details. We expect that our work is effective to enhance the details of depth image from 3D sensors and to provide a high-fidelity virtual reality experience.

  2. Image Information Mining Utilizing Hierarchical Segmentation

    NASA Technical Reports Server (NTRS)

    Tilton, James C.; Marchisio, Giovanni; Koperski, Krzysztof; Datcu, Mihai

    2002-01-01

    The Hierarchical Segmentation (HSEG) algorithm is an approach for producing high quality, hierarchically related image segmentations. The VisiMine image information mining system utilizes clustering and segmentation algorithms for reducing visual information in multispectral images to a manageable size. The project discussed herein seeks to enhance the VisiMine system through incorporating hierarchical segmentations from HSEG into the VisiMine system.

  3. Theory and Practice: How Filming "Learning in the Real World" Helps Students Make the Connection

    ERIC Educational Resources Information Center

    Commander, Nannette Evans; Ward, Teresa E.; Zabrucky, Karen M.

    2012-01-01

    This article describes an assignment, titled "Learning in the Real World," designed for graduate students in a learning theory course. Students work in small groups to create high quality audio-visual films that present "real learning" through interviews and/or observations of learners. Students select topics relevant to theories we are discussing…

  4. Elements of Success: WorkReady Philadelphia Program Year 2011-2012 Report

    ERIC Educational Resources Information Center

    Philadelphia Youth Network, 2012

    2012-01-01

    What does it take to deliver WorkReady Philadelphia's high-quality career-connected programming? In short, it's all about the "elements"--those essential components of the system that combine to produce success for young people. This 2011-12 WorkReady report reinforces this theme by using visual aspects of the "Periodic Table of…

  5. Effects of a Sports Camp Practicum on Attitudes toward Children with Visual Impairments and Deafblindness

    ERIC Educational Resources Information Center

    Lieberman, Lauren J.; Wilson, Sandy

    2005-01-01

    Physical activity is an important component of a positive quality of life for all individuals. Lack of physical activity can lead to increased risk of cancer, heart disease, high blood pressure, diabetes, and obesity. For all children, physical activity that includes fitness (cardiovascular and muscular endurance, muscle strength, flexibility, and…

  6. Development of Art Appreciation in 11-14 Year-Old Students

    ERIC Educational Resources Information Center

    Duh, Matjaž; Zupancic, Tomaž; Cagran, Branka

    2014-01-01

    Modern art curricula derive from the assumption that visual arts education can be of a high quality only if productive and receptive artistic activities are implemented. In art education practice, we are able to follow incentives for artistic expression but pay less attention to developing art appreciation that is based on developing as subtle…

  7. A La Carts: You Want Wireless Mobility? Have a COW

    ERIC Educational Resources Information Center

    Villano, Matt

    2006-01-01

    Computers on wheels, or COWs, combine the wireless technology of today with the audio/visual carts of yesteryear for an entirely new spin on mobility. Increasingly used by districts with laptop computing initiatives, COWs are among the hottest high-tech sellers in schools today, according to market research firm Quality Education Data. In this…

  8. Making Materials Based on TeX and CAS/DGS--Reports on CADGME 2012 Conference Working Group

    ERIC Educational Resources Information Center

    Kaneko, Masataka; Yamashita, Satoshi; Kitahara, Kiyoshi; Maeda, Yoshifumi; Usui, Hisashi; Takato, Setsuo

    2014-01-01

    TeX has become one of the most popular tools for editing teaching materials or textbooks in collegiate mathematics education, since it enables usual mathematics teachers to easily produce high-quality mathematical documents. Its capabilities for visualization and computation are fairly limited, so that many teachers simultaneously use various…

  9. A Nationwide Cross-Sectional Survey of Sleep-Related Problems in Japanese Visually Impaired Patients: Prevalence and Association with Health-Related Quality of Life.

    PubMed

    Tamura, Norihisa; Sasai-Sakuma, Taeko; Morita, Yuko; Okawa, Masako; Inoue, Shigeru; Inoue, Yuichi

    2016-12-15

    This questionnaire-based cross-sectional study was conducted (1) to estimate the prevalence of sleep-related problems, and (2) to explore factors associated with lower physical/mental quality of life (QOL), particularly addressing sleep-related problems among Japanese visually impaired people. This nationwide questionnaire-based survey was administered to visually impaired individuals through the Japan Federation of the Blind. Visually impaired individuals without light perception (LP) (n = 311), those with LP (n = 287), and age-matched and gender-matched controls (n = 615) were eligible for this study. Study questionnaires elicited demographic information, and information about visual impairment status, sleep-related problems, and health-related quality of life. Visually impaired individuals with and without LP showed higher prevalence rates of irregular sleep-wake patterns and difficulty maintaining sleep than controls (34.7% and 29.4% vs. 15.8%, 60.1% and 46.7% vs. 26.8%, respectively; p < 0.001). These sleep-related problems were observed more frequently in visually impaired individuals without LP than in those with LP. Non-restorative sleep or excessive daytime sleepiness was associated with lower mental/physical QOL in visually impaired individuals with LP and in control subjects. However, visually impaired individuals without LP showed irregular sleep-wake pattern or difficulty waking up at the desired time, which was associated with lower mental/physical QOL. Sleep-related problems were observed more frequently in visually impaired individuals than in controls. Moreover, the rates of difficulties were higher among subjects without LP. Sleep-related problems, especially circadian rhythm-related ones, can be associated with lower mental/physical QOL in visually impaired individuals without LP. © 2016 American Academy of Sleep Medicine

  10. [The status quo and expectation of optometry research in China].

    PubMed

    Qu, Jia

    2015-01-01

    The eye care problems related to optometry involve a wide range, including visual problems during eye disease recovery, visual quality in surgical or non-surgical refractive corrections, and the etiological investigation of functional eye diseases like myopia. This article covers the current challenges to visual health care and the academic developments and contributions of optometry in China, including fundamental researches of myopia, refractive surgery and visual quality, and functional eye disease investigations. Some of the researches have certain impacts both domestically and overseas. Furthermore, scientific evidences to solve clinical problems and the current academic focuses that we should pay attention to are provided.

  11. Correction of Refractive Errors in Rhesus Macaques (Macaca mulatta) Involved in Visual Research

    PubMed Central

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-01-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals. PMID:25427343

  12. Correction of refractive errors in rhesus macaques (Macaca mulatta) involved in visual research.

    PubMed

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-08-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals.

  13. Nonlinear dimensionality reduction methods for synthetic biology biobricks' visualization.

    PubMed

    Yang, Jiaoyun; Wang, Haipeng; Ding, Huitong; An, Ning; Alterovitz, Gil

    2017-01-19

    Visualizing data by dimensionality reduction is an important strategy in Bioinformatics, which could help to discover hidden data properties and detect data quality issues, e.g. data noise, inappropriately labeled data, etc. As crowdsourcing-based synthetic biology databases face similar data quality issues, we propose to visualize biobricks to tackle them. However, existing dimensionality reduction methods could not be directly applied on biobricks datasets. Hereby, we use normalized edit distance to enhance dimensionality reduction methods, including Isomap and Laplacian Eigenmaps. By extracting biobricks from synthetic biology database Registry of Standard Biological Parts, six combinations of various types of biobricks are tested. The visualization graphs illustrate discriminated biobricks and inappropriately labeled biobricks. Clustering algorithm K-means is adopted to quantify the reduction results. The average clustering accuracy for Isomap and Laplacian Eigenmaps are 0.857 and 0.844, respectively. Besides, Laplacian Eigenmaps is 5 times faster than Isomap, and its visualization graph is more concentrated to discriminate biobricks. By combining normalized edit distance with Isomap and Laplacian Eigenmaps, synthetic biology biobircks are successfully visualized in two dimensional space. Various types of biobricks could be discriminated and inappropriately labeled biobricks could be determined, which could help to assess crowdsourcing-based synthetic biology databases' quality, and make biobricks selection.

  14. Calculating the quality of public high-throughput sequencing data to obtain a suitable subset for reanalysis from the Sequence Read Archive.

    PubMed

    Ohta, Tazro; Nakazato, Takeru; Bono, Hidemasa

    2017-06-01

    It is important for public data repositories to promote the reuse of archived data. In the growing field of omics science, however, the increasing number of submissions of high-throughput sequencing (HTSeq) data to public repositories prevents users from choosing a suitable data set from among the large number of search results. Repository users need to be able to set a threshold to reduce the number of results to obtain a suitable subset of high-quality data for reanalysis. We calculated the quality of sequencing data archived in a public data repository, the Sequence Read Archive (SRA), by using the quality control software FastQC. We obtained quality values for 1 171 313 experiments, which can be used to evaluate the suitability of data for reuse. We also visualized the data distribution in SRA by integrating the quality information and metadata of experiments and samples. We provide quality information of all of the archived sequencing data, which enable users to obtain sufficient quality sequencing data for reanalyses. The calculated quality data are available to the public in various formats. Our data also provide an example of enhancing the reuse of public data by adding metadata to published research data by a third party. © The Authors 2017. Published by Oxford University Press.

  15. NASA GES DISC Level 2 Aerosol Analysis and Visualization Services

    NASA Technical Reports Server (NTRS)

    Wei, Jennifer; Petrenko, Maksym; Ichoku, Charles; Yang, Wenli; Johnson, James; Zhao, Peisheng; Kempler, Steve

    2015-01-01

    Overview of NASA GES DISC Level 2 aerosol analysis and visualization services: DQViz (Data Quality Visualization)MAPSS (Multi-sensor Aerosol Products Sampling System), and MAPSS_Explorer (Multi-sensor Aerosol Products Sampling System Explorer).

  16. Preliminary Study for a Tetrahedron Formation: Quality Factors and Visualization

    NASA Technical Reports Server (NTRS)

    Guzman, Jose J.; Schiff, Conrad; Bauer, Frank (Technical Monitor)

    2002-01-01

    Spacecraft flying in tetrahedron formations are excellent for electromagnetic and plasma studies. The quality of the science recorded is strongly affected by the tetrahedron evolution. This paper is a preliminary study on the computation of quality factors and visualization for a formation of four or five satellites. Four of the satellites are arranged geometrically in a tetrahedron shape. If a fifth satellite is present, it is arbitrarily initialized at the geometric center of the tetrahedron. The fifth satellite could act as a collector or as a spare spacecraft. Tetrahedron natural coordinates are employed for the initialization. The natural orbit evolution is visualized in geocentric equatorial inertial and in geocentric solar magnetospheric coordinates.

  17. Direct imaging of isofrequency contours in photonic structures

    DOE PAGES

    Regan, E. C.; Igarashi, Y.; Zhen, B.; ...

    2016-11-25

    The isofrequency contours of a photonic crystal are important for predicting and understanding exotic optical phenomena that are not apparent from high-symmetry band structure visualizations. We demonstrate a method to directly visualize the isofrequency contours of high-quality photonic crystal slabs that show quantitatively good agreement with numerical results throughout the visible spectrum. Our technique relies on resonance-enhanced photon scattering from generic fabrication disorder and surface roughness, so it can be applied to general photonic and plasmonic crystals or even quasi-crystals. We also present an analytical model of the scattering process, which explains the observation of isofrequency contours in our technique.more » Furthermore, the isofrequency contours provide information about the characteristics of the disorder and therefore serve as a feedback tool to improve fabrication processes.« less

  18. Filter methods to preserve local contrast and to avoid artifacts in gamut mapping

    NASA Astrophysics Data System (ADS)

    Meili, Marcel; Küpper, Dennis; Barańczuk, Zofia; Caluori, Ursina; Simon, Klaus

    2010-01-01

    Contrary to high dynamic range imaging, the preservation of details and the avoidance of artifacts is not explicitly considered in popular color management systems. An effective way to overcome these difficulties is image filtering. In this paper we investigate several image filter concepts for detail preservation as part of a practical gamut mapping strategy. In particular we define four concepts including various image filters and check their performance with a psycho-visual test. Additionally, we compare our performance evaluation to two image quality measures with emphasis on local contrast. Surprisingly, the most simple filter concept performs highly efficient and achieves an image quality which is comparable to the more established but slower methods.

  19. Modelling of 10 Gbps Free Space Optics Communication Link Using Array of Receivers in Moderate and Harsh Weather Conditions

    NASA Astrophysics Data System (ADS)

    Gupta, Amit; Shaina, Nagpal

    2017-08-01

    Intersymbol interference and attenuation of signal are two major parameters affecting the quality of transmission in Free Space Optical (FSO) Communication link. In this paper, the impact of these parameters on FSO communication link is analysed for delivering high-quality data transmission. The performance of the link is investigated under the influence of amplifier in the link. The performance parameters of the link like minimum bit error rate, received signal power and Quality factor are examined by employing erbium-doped fibre amplifier in the link. The effects of amplifier are visualized with the amount of received power. Further, the link is simulated for moderate weather conditions at various attenuation levels on transmitted signal. Finally, the designed link is analysed in adverse weather conditions by using high-power laser source for optimum performance.

  20. Corneal changes induced by laser ablation: study of the visual-quality evolution by a customized eye model

    NASA Astrophysics Data System (ADS)

    Ortiz, D.; Anera, R. G.; Saiz, J. M.; Jiménez, J. R.; Moreno, F.; Jiménez Del Barco, L.; González, F.

    2006-11-01

    This study focuses on the changes induced in both the asphericity and homogeneity of the cornea for a group of myopic eyes undergoing LASIK surgery. Eyes were characterized by a Kooijman-based customized eye model in which changes were introduced in the form of Gaussian-distributed refractive-index variations of given correlation length for the inhomogeneities and in the form of an expression, based on the modified Munnerlyn's paraxial formula, for the post-LASIK asphericity. Visual quality was evaluated in terms of the Modulation Transfer Function and the Point-Spread Function. The results show that, on average, the evolution of visual acuity is consistent with the change in corneal asphericity, while the evolution of contrast sensitivity requires a loss in corneal homogeneity in order to be explained. By including both effects in the model, the overall model performance in predicting visual quality is improved.

  1. A Structure-Based Distance Metric for High-Dimensional Space Exploration with Multi-Dimensional Scaling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hyun Jung; McDonnell, Kevin T.; Zelenyuk, Alla

    2014-03-01

    Although the Euclidean distance does well in measuring data distances within high-dimensional clusters, it does poorly when it comes to gauging inter-cluster distances. This significantly impacts the quality of global, low-dimensional space embedding procedures such as the popular multi-dimensional scaling (MDS) where one can often observe non-intuitive layouts. We were inspired by the perceptual processes evoked in the method of parallel coordinates which enables users to visually aggregate the data by the patterns the polylines exhibit across the dimension axes. We call the path of such a polyline its structure and suggest a metric that captures this structure directly inmore » high-dimensional space. This allows us to better gauge the distances of spatially distant data constellations and so achieve data aggregations in MDS plots that are more cognizant of existing high-dimensional structure similarities. Our MDS plots also exhibit similar visual relationships as the method of parallel coordinates which is often used alongside to visualize the high-dimensional data in raw form. We then cast our metric into a bi-scale framework which distinguishes far-distances from near-distances. The coarser scale uses the structural similarity metric to separate data aggregates obtained by prior classification or clustering, while the finer scale employs the appropriate Euclidean distance.« less

  2. Immersive Visual Data Analysis For Geoscience Using Commodity VR Hardware

    NASA Astrophysics Data System (ADS)

    Kreylos, O.; Kellogg, L. H.

    2017-12-01

    Immersive visualization using virtual reality (VR) display technology offers tremendous benefits for the visual analysis of complex three-dimensional data like those commonly obtained from geophysical and geological observations and models. Unlike "traditional" visualization, which has to project 3D data onto a 2D screen for display, VR can side-step this projection and display 3D data directly, in a pseudo-holographic (head-tracked stereoscopic) form, and does therefore not suffer the distortions of relative positions, sizes, distances, and angles that are inherent in 2D projection. As a result, researchers can apply their spatial reasoning skills to virtual data in the same way they can to real objects or environments. The UC Davis W.M. Keck Center for Active Visualization in the Earth Sciences (KeckCAVES, http://keckcaves.org) has been developing VR methods for data analysis since 2005, but the high cost of VR displays has been preventing large-scale deployment and adoption of KeckCAVES technology. The recent emergence of high-quality commodity VR, spearheaded by the Oculus Rift and HTC Vive, has fundamentally changed the field. With KeckCAVES' foundational VR operating system, Vrui, now running natively on the HTC Vive, all KeckCAVES visualization software, including 3D Visualizer, LiDAR Viewer, Crusta, Nanotech Construction Kit, and ProtoShop, are now available to small labs, single researchers, and even home users. LiDAR Viewer and Crusta have been used for rapid response to geologic events including earthquakes and landslides, to visualize the impacts of sealevel rise, to investigate reconstructed paleooceanographic masses, and for exploration of the surface of Mars. The Nanotech Construction Kit is being used to explore the phases of carbon in Earth's deep interior, while ProtoShop can be used to construct and investigate protein structures.

  3. A Controlled Agitation Process for Improving Quality of Canned Green Beans during Agitation Thermal Processing.

    PubMed

    Singh, Anika; Pratap Singh, Anubhav; Ramaswamy, Hosahalli S

    2016-06-01

    This work introduces the concept of a controlled agitation thermal process to reduce quality damage in liquid-particulate products during agitation thermal processing. Reciprocating agitation thermal processing (RA-TP) was used as the agitation thermal process. In order to reduce the impact of agitation, a new concept of "stopping agitations after sufficient development of cold-spot temperature" was proposed. Green beans were processed in No. 2 (307×409) cans filled with liquids of various consistency (0% to 2% CMC) at various frequencies (1 to 3 Hz) of RA-TP using a full-factorial design and heat penetration results were collected. Corresponding operator's process time to impart a 10-min process lethality (Fo ) and agitation time (AT) were calculated using heat penetration results. Accordingly, products were processed again by stopping agitations as per 3 agitation regimes, namely; full time agitation, equilibration time agitation, and partial time agitation. Processed products were photographed and tested for visual quality, color, texture, breakage of green beans, turbidity, and percentage of insoluble solids in can liquid. Results showed that stopping agitations after sufficient development of cold-spot temperatures is an effective way of reducing product damages caused by agitation (for example, breakage of beans and its leaching into liquid). Agitations till one-log temperature difference gave best color, texture and visual product quality for low-viscosity liquid-particulate mixture and extended agitations till equilibration time was best for high-viscosity products. Thus, it was shown that a controlled agitation thermal process is more effective in obtaining high product quality as compared to a regular agitation thermal process. © 2016 Institute of Food Technologists®

  4. VAAPA: a web platform for visualization and analysis of alternative polyadenylation.

    PubMed

    Guan, Jinting; Fu, Jingyi; Wu, Mingcheng; Chen, Longteng; Ji, Guoli; Quinn Li, Qingshun; Wu, Xiaohui

    2015-02-01

    Polyadenylation [poly(A)] is an essential process during the maturation of most mRNAs in eukaryotes. Alternative polyadenylation (APA) as an important layer of gene expression regulation has been increasingly recognized in various species. Here, a web platform for visualization and analysis of alternative polyadenylation (VAAPA) was developed. This platform can visualize the distribution of poly(A) sites and poly(A) clusters of a gene or a section of a chromosome. It can also highlight genes with switched APA sites among different conditions. VAAPA is an easy-to-use web-based tool that provides functions of poly(A) site query, data uploading, downloading, and APA sites visualization. It was designed in a multi-tier architecture and developed based on Smart GWT (Google Web Toolkit) using Java as the development language. VAAPA will be a valuable addition to the community for the comprehensive study of APA, not only by making the high quality poly(A) site data more accessible, but also by providing users with numerous valuable functions for poly(A) site analysis and visualization. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Observational study of differences in head position for high notes in famous classical and non-classical male singers.

    PubMed

    Amarante Andrade, Pedro; Švec, Jan G

    2016-07-01

    Differences in classical and non-classical singing are due primarily to aesthetic style requirements. The head position can affect the sound quality. This study aimed at comparing the head position for famous classical and non-classical male singers performing high notes. Images of 39 Western classical and 34 non-classical male singers during live performances were obtained from YouTube. Ten raters evaluated the frontal rotational head position (depression versus elevation) and transverse head position (retraction versus protraction) visually using a visual analogue scale. The results showed a significant difference for frontal rotational head position. Most non-classical singers in the sample elevated their heads for high notes while the classical singers were observed to keep it around the neutral position. This difference may be attributed to different singing techniques and phonatory system adjustments utilized by each group.

  6. Nondestructive evaluation for sorting red maple logs

    Treesearch

    Xiping Wang; Robert J. Ross; David W. Green; Karl Englund; Michael Wolcott

    2000-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  7. Sub aquatic 3D visualization and temporal analysis utilizing ArcGIS online and 3D applications

    EPA Science Inventory

    We used 3D Visualization tools to illustrate some complex water quality data we’ve been collecting in the Great Lakes. These data include continuous tow data collected from our research vessel the Lake Explorer II, and continuous water quality data collected from an autono...

  8. BatMass: a Java Software Platform for LC-MS Data Visualization in Proteomics and Metabolomics.

    PubMed

    Avtonomov, Dmitry M; Raskind, Alexander; Nesvizhskii, Alexey I

    2016-08-05

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC-MS-based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC-MS data are often overlooked, and assessment of an experiment's success is based on some derived metrics such as "the number of identified compounds". The human brain interprets visual data much better than plain text, hence the saying "a picture is worth a thousand words". Here, we present the BatMass software package, which allows for performing quick quality control of raw LC-MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC-MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration.

  9. BatMass: a Java software platform for LC/MS data visualization in proteomics and metabolomics

    PubMed Central

    Avtonomov, Dmitry; Raskind, Alexander; Nesvizhskii, Alexey I.

    2017-01-01

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC/MS based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC/MS data are often overlooked and assessment of an experiment's success is based on some derived metrics such as “the number of identified compounds”. Human brain interprets visual data much better than plain text, hence the saying “a picture is worth a thousand words”. Here we present BatMass software package which allows to perform quick quality control of raw LC/MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC/MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration. PMID:27306858

  10. Safety, efficacy, and quality of life following sutureless vitrectomy for symptomatic vitreous floaters.

    PubMed

    Mason, John O; Neimkin, Michael G; Mason, John O; Friedman, Duncan A; Feist, Richard M; Thomley, Martin L; Albert, Michael A

    2014-06-01

    To determine the safety, efficacy, and quality of life improvement following sutureless 25-gauge pars plana vitrectomy for symptomatic floaters. Patients with symptomatic vitreous floaters who underwent sutureless vitrectomy between January 2008 and January 2011 were included. Data were collected regarding baseline preoperative characteristics, postoperative outcomes, complications, and a nine-item quality-of-life survey completed by each patient. One hundred and sixty-eight eyes (143 patients) underwent sutureless 25-gauge pars plana vitrectomy for symptomatic vitreous floaters. Mean Snellen visual acuity was 20/40 preoperatively and improved to 20/25 postoperatively (P < 0.0001). Iatrogenic retinal breaks occurred in 12 of 168 eyes (7.1%). Intraoperative posterior vitreous detachment induction was not found to increase the risk of retinal breaks (P = 1.000). Postoperative complications occurred in three eyes, of which one had transient cystoid macular edema and two had transient vitreous hemorrhage. Approximately 88.8% of patients completed a quality-of-life survey, which revealed that 96% were "satisfied" with the results of the operation, and 94% rated the experience as a "complete success." Sutureless 25-gauge pars plana vitrectomy for symptomatic vitreous floaters improved visual acuity, resulted in a high patient satisfaction quality-of-life survey, and had a low rate of postoperative complications. Sutureless pars plana vitrectomy should be considered as a viable means of managing patients with symptomatic vitreous floaters.

  11. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    PubMed

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  12. Visual Prostheses: The Enabling Technology to Give Sight to the Blind

    PubMed Central

    Maghami, Mohammad Hossein; Sodagar, Amir Masoud; Lashay, Alireza; Riazi-Esfahani, Hamid; Riazi-Esfahani, Mohammad

    2014-01-01

    Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices. PMID:25709777

  13. Fear of heights and visual height intolerance.

    PubMed

    Brandt, Thomas; Huppert, Doreen

    2014-02-01

    The aim of this review is, first, to cover the different aspects of visual height intolerance such as historical descriptions, definition of terms, phenomenology of the condition, neurophysiological control of gaze, stance and locomotion, and therapy, and, second, to identify warranted epidemiological and experimental studies. Vivid descriptions of fear of heights can be found in ancient texts from the Greek, Roman, and Chinese classics. The life-time prevalence of visual height intolerance is as high as 28% in the general population, and about 50% of those who are susceptible report an impact on quality of life. When exposed to heights, visual exploration by eye and head movements is restricted, and the velocity of locomotion is reduced. Therapy for fear of heights is dominated by the behavioral techniques applied during real or virtual reality exposure. Their efficacy might be facilitated by the administration of D-cycloserine or glucocorticoids. Visual height intolerance has a considerable impact on daily life and interpersonal interactions. It is much more frequent than fear of heights, which is defined as an environmental subtype of a specific phobia. There is certainly a continuum stretching from acrophobia to a less-pronounced visual height intolerance, to which the categorical distinction of a specific phobia does not apply.

  14. Visual neglect following stroke: current concepts and future focus.

    PubMed

    Ting, Darren S J; Pollock, Alex; Dutton, Gordon N; Doubal, Fergus N; Ting, Daniel S W; Thompson, Michelle; Dhillon, Baljean

    2011-01-01

    Visual neglect is a common, yet frequently overlooked, neurological disorder following stroke characterized by a deficit in attention and appreciation of stimuli on the contralesional side of the body. It has a profound functional impact on affected individuals. A assessment and management of this condition are hindered, however, by the lack of professional awareness and clinical guidelines. Recent evidence suggests that the underlying deficit in visual attention is due to a disrupted internalized representation of the outer world rather than a disorder of sensory inputs. Dysfunction of the cortical domains and white-matter tracts, as well as inter-hemispheric imbalance, have been implicated in the various manifestations of visual neglect. Optimal diagnosis requires careful history-taking from the patient, family, and friends, in addition to clinical assessment with the line bisection test, the star cancellation test, and the Catherine Bergego Scale. Early recognition and prompt rehabilitation employing a multidisciplinary approach is desirable. Although no treatment has been definitively shown to be of benefit, those with promise include prism adaptation, visual scanning therapy, and virtual reality-based techniques. Further high quality research to seek optimum short- and long-term rehabilitative strategies for visual neglect is required. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens

    PubMed Central

    de Medeiros, André Lins; de Araújo Rolim, André Gustavo; Motta, Antonio Francisco Pimenta; Ventura, Bruna Vieira; Vilar, César; Chaves, Mário Augusto Pereira Dias; Carricondo, Pedro Carlos; Hida, Wilson Takashi

    2017-01-01

    Purpose The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B). Methods This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. Results Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. Conclusion Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. PMID:29138533

  16. Impacts of soil moisture content on visual soil evaluation

    NASA Astrophysics Data System (ADS)

    Emmet-Booth, Jeremy; Forristal, Dermot; Fenton, Owen; Bondi, Giulia; Creamer, Rachel; Holden, Nick

    2017-04-01

    Visual Soil Examination and Evaluation (VSE) techniques offer tools for soil quality assessment. They involve the visual and tactile assessment of soil properties such as aggregate size and shape, porosity, redox morphology, soil colour and smell. An increasing body of research has demonstrated the reliability and utility of VSE techniques. However a number of limitations have been identified, including the potential impact of soil moisture variation during sampling. As part of a national survey of grassland soil quality in Ireland, an evaluation of the impact of soil moisture on two widely used VSE techniques was conducted. The techniques were Visual Evaluation of Soil Structure (VESS) (Guimarães et al., 2011) and Visual Soil Assessment (VSA) (Shepherd, 2009). Both generate summarising numeric scores that indicate soil structural quality, though employ different scoring mechanisms. The former requires the assessment of properties concurrently and the latter separately. Both methods were deployed on 20 sites across Ireland representing a range of soils. Additional samples were taken for soil volumetric water (θ) determination at 5-10 and 10-20 cm depth. No significant correlation was observed between θ 5-10 cm and either VSE technique. However, VESS scores were significantly related to θ 10-20 cm (rs = 0.40, sig = 0.02) while VSA scores were not (rs = -0.33, sig = 0.06). VESS and VSA scores can be grouped into quality classifications (good, moderate and poor). No significant mean difference was observed between θ 5-10 cm or θ 10-20 cm according to quality classification by either method. It was concluded that VESS scores may be affected by soil moisture variation while VSA appear unaffected. The different scoring mechanisms, where the separate assessment and scoring of individual properties employed by VSA, may limit soil moisture effects. However, moisture content appears not to affect overall structural quality classification by either method. References Guimarães, R.M.C., Ball, B.C. & Tormena, C.A. 2011. Improvements in the visual evaluation of soil structure, Soil Use and Management, 27, 3: 395-403 Shepherd, G.T. 2009. Visual Soil Assessment. Field guide for pastoral grazing and cropping on flat to rolling country. 2nd edn. Horizons regional council, New Zealand.

  17. High contrast microstructural visualization of natural acellular matrices by means of phase-based x-ray tomography

    NASA Astrophysics Data System (ADS)

    Hagen, Charlotte K.; Maghsoudlou, Panagiotis; Totonelli, Giorgia; Diemoz, Paul C.; Endrizzi, Marco; Rigon, Luigi; Menk, Ralf-Hendrik; Arfelli, Fulvia; Dreossi, Diego; Brun, Emmanuel; Coan, Paola; Bravin, Alberto; de Coppi, Paolo; Olivo, Alessandro

    2015-12-01

    Acellular scaffolds obtained via decellularization are a key instrument in regenerative medicine both per se and to drive the development of future-generation synthetic scaffolds that could become available off-the-shelf. In this framework, imaging is key to the understanding of the scaffolds’ internal structure as well as their interaction with cells and other organs, including ideally post-implantation. Scaffolds of a wide range of intricate organs (esophagus, lung, liver and small intestine) were imaged with x-ray phase contrast computed tomography (PC-CT). Image quality was sufficiently high to visualize scaffold microarchitecture and to detect major anatomical features, such as the esophageal mucosal-submucosal separation, pulmonary alveoli and intestinal villi. These results are a long-sought step for the field of regenerative medicine; until now, histology and scanning electron microscopy have been the gold standard to study the scaffold structure. However, they are both destructive: hence, they are not suitable for imaging scaffolds prior to transplantation, and have no prospect for post-transplantation use. PC-CT, on the other hand, is non-destructive, 3D and fully quantitative. Importantly, not only do we demonstrate achievement of high image quality at two different synchrotron facilities, but also with commercial x-ray equipment, which makes the method available to any research laboratory.

  18. BiGG Models: A platform for integrating, standardizing and sharing genome-scale models

    DOE PAGES

    King, Zachary A.; Lu, Justin; Drager, Andreas; ...

    2015-10-17

    In this study, genome-scale metabolic models are mathematically structured knowledge bases that can be used to predict metabolic pathway usage and growth phenotypes. Furthermore, they can generate and test hypotheses when integrated with experimental data. To maximize the value of these models, centralized repositories of high-quality models must be established, models must adhere to established standards and model components must be linked to relevant databases. Tools for model visualization further enhance their utility. To meet these needs, we present BiGG Models (http://bigg.ucsd.edu), a completely redesigned Biochemical, Genetic and Genomic knowledge base. BiGG Models contains more than 75 high-quality, manually-curated genome-scalemore » metabolic models. On the website, users can browse, search and visualize models. BiGG Models connects genome-scale models to genome annotations and external databases. Reaction and metabolite identifiers have been standardized across models to conform to community standards and enable rapid comparison across models. Furthermore, BiGG Models provides a comprehensive application programming interface for accessing BiGG Models with modeling and analysis tools. As a resource for highly curated, standardized and accessible models of metabolism, BiGG Models will facilitate diverse systems biology studies and support knowledge-based analysis of diverse experimental data.« less

  19. BiGG Models: A platform for integrating, standardizing and sharing genome-scale models

    PubMed Central

    King, Zachary A.; Lu, Justin; Dräger, Andreas; Miller, Philip; Federowicz, Stephen; Lerman, Joshua A.; Ebrahim, Ali; Palsson, Bernhard O.; Lewis, Nathan E.

    2016-01-01

    Genome-scale metabolic models are mathematically-structured knowledge bases that can be used to predict metabolic pathway usage and growth phenotypes. Furthermore, they can generate and test hypotheses when integrated with experimental data. To maximize the value of these models, centralized repositories of high-quality models must be established, models must adhere to established standards and model components must be linked to relevant databases. Tools for model visualization further enhance their utility. To meet these needs, we present BiGG Models (http://bigg.ucsd.edu), a completely redesigned Biochemical, Genetic and Genomic knowledge base. BiGG Models contains more than 75 high-quality, manually-curated genome-scale metabolic models. On the website, users can browse, search and visualize models. BiGG Models connects genome-scale models to genome annotations and external databases. Reaction and metabolite identifiers have been standardized across models to conform to community standards and enable rapid comparison across models. Furthermore, BiGG Models provides a comprehensive application programming interface for accessing BiGG Models with modeling and analysis tools. As a resource for highly curated, standardized and accessible models of metabolism, BiGG Models will facilitate diverse systems biology studies and support knowledge-based analysis of diverse experimental data. PMID:26476456

  20. A novel x-ray detector design with higher DQE and reduced aliasing: Theoretical analysis of x-ray reabsoprtion in detector converter material

    NASA Astrophysics Data System (ADS)

    Nano, Tomi; Escartin, Terenz; Karim, Karim S.; Cunningham, Ian A.

    2016-03-01

    The ability to improve visualization of structural information in digital radiography without increasing radiation exposures requires improved image quality across all spatial frequencies, especially at high frequencies. The detective quantum efficiency (DQE) as a function of spatial frequency quantifies image quality given by an x-ray detector. We present a method of increasing DQE at high spatial frequencies by improving the modulation transfer function (MTF) and reducing noise aliasing. The Apodized Aperature Pixel (AAP) design uses a detector with micro-elements to synthesize desired pixels and provide higher DQE than conventional detector designs. A cascaded system analysis (CSA) that incorporates x-ray interactions is used for comparison of the theoretical MTF, noise power spectrum (NPS), and DQE. Signal and noise transfer through the converter material is shown to consist of correlated an uncorrelated terms. The AAP design was shown to improve the DQE of both material types that have predominantly correlated transfer (such as CsI) and predominantly uncorrelated transfer (such as Se). Improvement in the MTF by 50% and the DQE by 100% at the sampling cut-off frequency is obtained when uncorrelated transfer is prevalent through the converter material. Optimizing high-frequency DQE results in improved image contrast and visualization of small structures and fine-detail.

  1. Similarity-dissimilarity plot for visualization of high dimensional data in biomedical pattern classification.

    PubMed

    Arif, Muhammad

    2012-06-01

    In pattern classification problems, feature extraction is an important step. Quality of features in discriminating different classes plays an important role in pattern classification problems. In real life, pattern classification may require high dimensional feature space and it is impossible to visualize the feature space if the dimension of feature space is greater than four. In this paper, we have proposed a Similarity-Dissimilarity plot which can project high dimensional space to a two dimensional space while retaining important characteristics required to assess the discrimination quality of the features. Similarity-dissimilarity plot can reveal information about the amount of overlap of features of different classes. Separable data points of different classes will also be visible on the plot which can be classified correctly using appropriate classifier. Hence, approximate classification accuracy can be predicted. Moreover, it is possible to know about whom class the misclassified data points will be confused by the classifier. Outlier data points can also be located on the similarity-dissimilarity plot. Various examples of synthetic data are used to highlight important characteristics of the proposed plot. Some real life examples from biomedical data are also used for the analysis. The proposed plot is independent of number of dimensions of the feature space.

  2. Lacking control over the trade-off between quality and quantity in visual short-term memory.

    PubMed

    Murray, Alexandra M; Nobre, Anna C; Astle, Duncan E; Stokes, Mark G

    2012-01-01

    Visual short-term memory (VSTM) is limited in the quantity and quality of items that can be retained over time. Importantly, these two mnemonic parameters interact: increasing the number of items in VSTM reduces the quality with which they are represented. Here, we ask whether this trade-off is under top-down control. Specifically, we test whether participants can strategically optimise the trade-off between quality and quantity for VSTM according to task demands. We manipulated strategic trade-off by varying expectations about the number of to-be-remembered items (Experiments 1-2) or the precision required for the memory-based judgement (Experiment 3). In a final experiment, we manipulated both variables in a complementary way to maximise the motivation to strategically control the balance between number and the quality of items encoded into VSTM. In different blocks, performance would benefit most either by encoding a large number of items with low precision or by encoding a small number of items with high precision (Experiment 4). In all experiments, we compared VSTM performance on trials matched for mnemonic demand, but within contexts emphasising the quality or quantity of VSTM representations. Across all four experiments, we found no evidence to suggest that participants use this contextual information to bias the balance between the number and precision of items in VSTM. Rather, our data suggest that the trade-off may be determined primarily by stimulus-driven factors at encoding.

  3. The impact of glaucoma on quality of life in Ethiopia: a case-control study.

    PubMed

    Ayele, Fisseha A; Zeraye, Banchamelak; Assefa, Yared; Legesse, Kbrom; Azale, Telake; Burton, Matthew J

    2017-12-13

    Glaucoma is a chronic disease characterized by irreversible optic nerve damage and visual field loss that leads to visual impairment and blindness; ultimately limiting personal independence and compromising overall quality of life of affected individuals. There is paucity of information on how glaucoma affects the quality of life of patients in low and middle-income countries where resources for both diagnosis and treatment of such conditions are limited. In this study we investigate the impact of glaucoma on quality of life in Ethiopian patients. The quality of life of 307 glaucoma patients and 76 normal controls that were frequency matched to the age and sex profiles of the cases was assessed using Amharic version of Glaucoma Quality of Life -15 questionnaire. Linear regression models and the t-test were employed to compare significant differences in GQL-15 scores and to generate mean and mean differences between cases and controls respectively. The mean GQL-15 score in the glaucoma cases was substantially higher (indicating poorer quality of life) than the controls [cases 46.3 (95% CI, 28.8-63.8) and controls 18.6 (95% CI, 15.2-22.0), p < 0.0001]. Cases with normal visual acuity and mild glaucoma had significantly higher scores than the controls. Poorer quality of life was associated with age ≥ 71 years old 51.1 (95%CI, 26.2-75.9), rural residence 55.7 (95%CI, 49.9-61.5), monthly income of <400 Birr (53.1; 95%CI, 50.5-55.6), diagnosis time 1-5 years (49.6; 95%CI, 41.2-57.9), severe visual impairment (70.5; 95%CI, 58.1-82.8), and advanced glaucoma (50.9; 95%CI, 43.6-58.3). These glaucoma patients, including those with normal visual acuity and early disease, had poorer quality of life compared to normal controls. Older age, rural residence, low income and more advanced disease were significantly associated with poorer quality of life. There is a need to increase awareness of the impact of glaucoma among clinicians, patients and their families, for a better understanding of the impact this disease has on a person's life.

  4. No-reference quality assessment based on visual perception

    NASA Astrophysics Data System (ADS)

    Li, Junshan; Yang, Yawei; Hu, Shuangyan; Zhang, Jiao

    2014-11-01

    The visual quality assessment of images/videos is an ongoing hot research topic, which has become more and more important for numerous image and video processing applications with the rapid development of digital imaging and communication technologies. The goal of image quality assessment (IQA) algorithms is to automatically assess the quality of images/videos in agreement with human quality judgments. Up to now, two kinds of models have been used for IQA, namely full-reference (FR) and no-reference (NR) models. For FR models, IQA algorithms interpret image quality as fidelity or similarity with a perfect image in some perceptual space. However, the reference image is not available in many practical applications, and a NR IQA approach is desired. Considering natural vision as optimized by the millions of years of evolutionary pressure, many methods attempt to achieve consistency in quality prediction by modeling salient physiological and psychological features of the human visual system (HVS). To reach this goal, researchers try to simulate HVS with image sparsity coding and supervised machine learning, which are two main features of HVS. A typical HVS captures the scenes by sparsity coding, and uses experienced knowledge to apperceive objects. In this paper, we propose a novel IQA approach based on visual perception. Firstly, a standard model of HVS is studied and analyzed, and the sparse representation of image is accomplished with the model; and then, the mapping correlation between sparse codes and subjective quality scores is trained with the regression technique of least squaresupport vector machine (LS-SVM), which gains the regressor that can predict the image quality; the visual metric of image is predicted with the trained regressor at last. We validate the performance of proposed approach on Laboratory for Image and Video Engineering (LIVE) database, the specific contents of the type of distortions present in the database are: 227 images of JPEG2000, 233 images of JPEG, 174 images of White Noise, 174 images of Gaussian Blur, 174 images of Fast Fading. The database includes subjective differential mean opinion score (DMOS) for each image. The experimental results show that the proposed approach not only can assess many kinds of distorted images quality, but also exhibits a superior accuracy and monotonicity.

  5. Quality and Cultural Sensitivity of Linguistically Appropriate Cardiovascular Disease Information for Chinese Immigrants: A Review of Online Resources From Heart Foundations.

    PubMed

    Li, Jialin; Lowres, Nicole; Jin, Kai; Zhang, Ling; Neubeck, Lis; Gallagher, Robyn

    Chinese immigrants are at an increased risk for cardiovascular diseases (CVDs) compared with Chinese nationals partly because of lifestyle changes and knowledge deficits. Translated patient resources are available on the Internet and are often provided by health professionals; however, the quality and cultural sensitivity of these resources have not been reported. The aim of this study was to assess the availability, quality, and cultural sensitivity of Chinese-language information available from national "Heart Foundations" (cardiac research bodies, nongovernmental organisations) of the 5 most popular destinations of Chinese immigration. This study is a descriptive research in which national "Heart Foundation" websites were systematically searched for Chinese-language CVD patient education resources. Quality (content, identification, structure) was assessed using the Ensuring Quality Information for Patients instrument. Cultural sensitivity was evaluated using the Cultural Sensitivity Assessment Tool. From 107 identified resources, 33 were CVD specific: coronary heart disease (n = 20), arrhythmias (n = 7), and heart failure (n = 6). Quality of resources was adequate (mean Ensuring Quality Information for Patients score, 69%), but scores varied significantly (min, 60%; max, 85%). Although all resources were classified as culturally sensitive (Cultural Sensitivity Assessment Tool score ≥ 2.5), 2 resources scored low (≤2.5) for visual impact, and across all resources, written and visual domains were assessed as least culturally sensitive. Most resources lacked culturally specific references. Chinese-language CVD resources were inconsistent in the supply of key information. Quality and level of cultural sensitivity were adequate, but most resources lacked culturally specific references. Comprehensive, high-quality CVD resources powered by Editorial Manager and ProduXion Manager from Aries Systems Corporation tailored for Chinese immigrants are urgently needed for healthcare providers to support CVD education and care of patients belonging to this population.

  6. Geoinformatics 2007: data to knowledge

    USGS Publications Warehouse

    Brady, Shailaja R.; Sinha, A. Krishna; Gundersen, Linda C.

    2007-01-01

    Geoinformatics is the term used to describe a variety of efforts to promote collaboration between the computer sciences and the geosciences to solve complex scientific questions. It refers to the distributed, integrated digital information system and working environment that provides innovative means for the study of the Earth systems, as well as other planets, through use of advanced information technologies. Geoinformatics activities range from major research and development efforts creating new technologies to provide high-quality, sustained production-level services for data discovery, integration and analysis, to small, discipline-specific efforts that develop earth science data collections and data analysis tools serving the needs of individual communities. The ultimate vision of Geoinformatics is a highly interconnected data system populated with high quality, freely available data, as well as, a robust set of software for analysis, visualization, and modeling.

  7. Visualization of LC-MS/MS proteomics data in MaxQuant.

    PubMed

    Tyanova, Stefka; Temu, Tikira; Carlson, Arthur; Sinitcyn, Pavel; Mann, Matthias; Cox, Juergen

    2015-04-01

    Modern software platforms enable the analysis of shotgun proteomics data in an automated fashion resulting in high quality identification and quantification results. Additional understanding of the underlying data can be gained with the help of advanced visualization tools that allow for easy navigation through large LC-MS/MS datasets potentially consisting of terabytes of raw data. The updated MaxQuant version has a map navigation component that steers the users through mass and retention time-dependent mass spectrometric signals. It can be used to monitor a peptide feature used in label-free quantification over many LC-MS runs and visualize it with advanced 3D graphic models. An expert annotation system aids the interpretation of the MS/MS spectra used for the identification of these peptide features. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Image Quality Analysis of Various Gastrointestinal Endoscopes: Why Image Quality Is a Prerequisite for Proper Diagnostic and Therapeutic Endoscopy

    PubMed Central

    Ko, Weon Jin; An, Pyeong; Ko, Kwang Hyun; Hahm, Ki Baik; Hong, Sung Pyo

    2015-01-01

    Arising from human curiosity in terms of the desire to look within the human body, endoscopy has undergone significant advances in modern medicine. Direct visualization of the gastrointestinal (GI) tract by traditional endoscopy was first introduced over 50 years ago, after which fairly rapid advancement from rigid esophagogastric scopes to flexible scopes and high definition videoscopes has occurred. In an effort towards early detection of precancerous lesions in the GI tract, several high-technology imaging scopes have been developed, including narrow band imaging, autofocus imaging, magnified endoscopy, and confocal microendoscopy. However, these modern developments have resulted in fundamental imaging technology being skewed towards red-green-blue and this technology has obscured the advantages of other endoscope techniques. In this review article, we have described the importance of image quality analysis using a survey to consider the diversity of endoscope system selection in order to better achieve diagnostic and therapeutic goals. The ultimate aims can be achieved through the adoption of modern endoscopy systems that obtain high image quality. PMID:26473119

  9. Direct labeling and visualization of blood vessels with lipophilic carbocyanine dye DiI

    PubMed Central

    Li, Yiwen; Song, Ying; Zhao, Lian; Gaidosh, Gabriel; Laties, Alan M; Wen, Rong

    2009-01-01

    We describe a protocol to rapidly and reliably visualize blood vessels in experimental animals. Blood vessels are directly labeled by cardiac perfusion using a specially formulated aqueous solution containing 1,1′-dioctadecyl-3,3,3′,3′-tetramethylindocarbocyanine perchlorate (DiI), a lipophilic carbocyanine dye, which incorporates into endothelial cell membranes upon contact. By lateral diffusion, DiI also stains membrane structures, including angiogenic sprouts and pseudopodial processes that are not in direct contact. Tissues can be immediately examined by conventional and confocal fluorescence microscopy. High-quality serial optical sections using confocal microscopy are obtainable from thick tissue sections, especially at low magnification, for three-dimensional reconstruction. It takes less than 1 h to stain the vasculature in a whole animal. Compared with alternative techniques to visualize blood vessels, including space-occupying materials such as India ink or fluorescent dye-conjugated dextran, the corrosion casting technique, endothelial cell-specific markers and lectins, the present method simplifies the visualization of blood vessels and data analysis. PMID:18846097

  10. Visually Lossless JPEG 2000 for Remote Image Browsing

    PubMed Central

    Oh, Han; Bilgin, Ali; Marcellin, Michael

    2017-01-01

    Image sizes have increased exponentially in recent years. The resulting high-resolution images are often viewed via remote image browsing. Zooming and panning are desirable features in this context, which result in disparate spatial regions of an image being displayed at a variety of (spatial) resolutions. When an image is displayed at a reduced resolution, the quantization step sizes needed for visually lossless quality generally increase. This paper investigates the quantization step sizes needed for visually lossless display as a function of resolution, and proposes a method that effectively incorporates the resulting (multiple) quantization step sizes into a single JPEG2000 codestream. This codestream is JPEG2000 Part 1 compliant and allows for visually lossless decoding at all resolutions natively supported by the wavelet transform as well as arbitrary intermediate resolutions, using only a fraction of the full-resolution codestream. When images are browsed remotely using the JPEG2000 Interactive Protocol (JPIP), the required bandwidth is significantly reduced, as demonstrated by extensive experimental results. PMID:28748112

  11. Visualization of DNA in highly processed botanical materials.

    PubMed

    Lu, Zhengfei; Rubinsky, Maria; Babajanian, Silva; Zhang, Yanjun; Chang, Peter; Swanson, Gary

    2018-04-15

    DNA-based methods have been gaining recognition as a tool for botanical authentication in herbal medicine; however, their application in processed botanical materials is challenging due to the low quality and quantity of DNA left after extensive manufacturing processes. The low amount of DNA recovered from processed materials, especially extracts, is "invisible" by current technology, which has casted doubt on the presence of amplifiable botanical DNA. A method using adapter-ligation and PCR amplification was successfully applied to visualize the "invisible" DNA in botanical extracts. The size of the "invisible" DNA fragments in botanical extracts was around 20-220 bp compared to fragments of around 600 bp for the more easily visualized DNA in botanical powders. This technique is the first to allow characterization and visualization of small fragments of DNA in processed botanical materials and will provide key information to guide the development of appropriate DNA-based botanical authentication methods in the future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. [Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering].

    PubMed

    Günther, P; Tröger, J; Holland-Cunz, S; Waag, K L; Schenk, J P

    2006-08-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this.A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning.

  13. Low-Quality Housing Is Associated With Increased Risk of Malaria Infection: A National Population-Based Study From the Low Transmission Setting of Swaziland

    PubMed Central

    Dlamini, Nomcebo; Ntshalintshali, Nyasatu; Pindolia, Deepa; Allen, Regan; Nhlabathi, Nomcebo; Novotny, Joseph; Kang Dufour, Mi-Suk; Midekisa, Alemayehu; Gosling, Roly; LeMenach, Arnaud; Cohen, Justin; Dorsey, Grant; Greenhouse, Bryan; Kunene, Simon

    2017-01-01

    Abstract Background. Low-quality housing may confer risk of malaria infection, but evidence in low transmission settings is limited. Methods. To examine the relationship between individual level housing quality and locally acquired infection in children and adults, a population-based cross-sectional analysis was performed using existing surveillance data from the low transmission setting of Swaziland. From 2012 to 2015, cases were identified through standard diagnostics in health facilities and by loop-mediated isothermal amplification in active surveillance, with uninfected subjects being household members and neighbors. Housing was visually assessed in a home visit and then classified as low, high, or medium quality, based on housing components being traditional, modern, or both, respectively. Results. Overall, 11426 individuals were included in the study: 10960 uninfected and 466 infected (301 symptomatic and 165 asymptomatic). Six percent resided in low-quality houses, 26% in medium-quality houses, and 68% in high-quality houses. In adjusted models, low- and medium-quality construction was associated with increased risk of malaria compared with high-quality construction (adjusted odds ratio [AOR], 2.11 and 95% confidence interval [CI], 1.26–3.53 for low vs high; AOR, 1.56 and 95% CI, 1.15–2.11 for medium vs high). The relationship was independent of vector control, which also conferred a protective effect (AOR, 0.67; 95% CI, .50–.90) for sleeping under an insecticide-treated bed net or a sprayed structure compared with neither. Conclusions. Our study adds to the limited literature on housing quality and malaria risk from low transmission settings. Housing improvements may offer an attractive and sustainable additional strategy to support countries in malaria elimination. PMID:28580365

  14. Low-Quality Housing Is Associated With Increased Risk of Malaria Infection: A National Population-Based Study From the Low Transmission Setting of Swaziland.

    PubMed

    Dlamini, Nomcebo; Hsiang, Michelle S; Ntshalintshali, Nyasatu; Pindolia, Deepa; Allen, Regan; Nhlabathi, Nomcebo; Novotny, Joseph; Kang Dufour, Mi-Suk; Midekisa, Alemayehu; Gosling, Roly; LeMenach, Arnaud; Cohen, Justin; Dorsey, Grant; Greenhouse, Bryan; Kunene, Simon

    2017-01-01

    Low-quality housing may confer risk of malaria infection, but evidence in low transmission settings is limited. To examine the relationship between individual level housing quality and locally acquired infection in children and adults, a population-based cross-sectional analysis was performed using existing surveillance data from the low transmission setting of Swaziland. From 2012 to 2015, cases were identified through standard diagnostics in health facilities and by loop-mediated isothermal amplification in active surveillance, with uninfected subjects being household members and neighbors. Housing was visually assessed in a home visit and then classified as low, high, or medium quality, based on housing components being traditional, modern, or both, respectively. Overall, 11426 individuals were included in the study: 10960 uninfected and 466 infected (301 symptomatic and 165 asymptomatic). Six percent resided in low-quality houses, 26% in medium-quality houses, and 68% in high-quality houses. In adjusted models, low- and medium-quality construction was associated with increased risk of malaria compared with high-quality construction (adjusted odds ratio [AOR], 2.11 and 95% confidence interval [CI], 1.26-3.53 for low vs high; AOR, 1.56 and 95% CI, 1.15-2.11 for medium vs high). The relationship was independent of vector control, which also conferred a protective effect (AOR, 0.67; 95% CI, .50-.90) for sleeping under an insecticide-treated bed net or a sprayed structure compared with neither. Our study adds to the limited literature on housing quality and malaria risk from low transmission settings. Housing improvements may offer an attractive and sustainable additional strategy to support countries in malaria elimination. © The Author 2017. Published by Oxford University Press on behalf of Infectious Diseases Society of America.

  15. Autonomous Control Modes and Optimized Path Guidance for Shipboard Landing in High Sea States

    DTIC Science & Technology

    2016-04-28

    Contract # N00014-14-C-0004 Autonomous Control Modes and Optimized Path Guidance for Shipboard Landing in High Sea States Progress Report...Aviation (ONR BAA12-SN-0028). This project addresses the Sea Based Aviation (SBA) initiative in Advanced Handling Qualities for Rotorcraft. Landing a...and a degraded visual environment, workload during the landing task begins to approach the limits of a human pilot’s capability. It is a similarly

  16. Image quality classification for DR screening using deep learning.

    PubMed

    FengLi Yu; Jing Sun; Annan Li; Jun Cheng; Cheng Wan; Jiang Liu

    2017-07-01

    The quality of input images significantly affects the outcome of automated diabetic retinopathy (DR) screening systems. Unlike the previous methods that only consider simple low-level features such as hand-crafted geometric and structural features, in this paper we propose a novel method for retinal image quality classification (IQC) that performs computational algorithms imitating the working of the human visual system. The proposed algorithm combines unsupervised features from saliency map and supervised features coming from convolutional neural networks (CNN), which are fed to an SVM to automatically detect high quality vs poor quality retinal fundus images. We demonstrate the superior performance of our proposed algorithm on a large retinal fundus image dataset and the method could achieve higher accuracy than other methods. Although retinal images are used in this study, the methodology is applicable to the image quality assessment and enhancement of other types of medical images.

  17. Criteria for assessment of bridge aesthetic and visual quality

    NASA Astrophysics Data System (ADS)

    Rozentale, I.; Paeglitis, A.

    2017-10-01

    The bridge designers should find an ideal balance between structure, economy, buildability, aesthetics, durability and harmony with industrial or natural landscape. During the last years, the society has adopted documents providing procedures for evaluation of the impact of the structural appearance on surrounding landscape. The European Landscape Convention defines the landscape as an area perceived by people, whose character is the result of the action and interaction of natural and/or human factors. The Convention indicates the methods for clear and objective assessment of the landscape’s visual qualities. The esthetical qualities of bridge structures, appearance and attraction should satisfy not only the technicians - engineers and architects, but mostly the surrounding population. Each of these groups has a different perception of esthetical qualities of structure. Many authors have used different methods and criteria for assessment of bridge aesthetics. The aim of this paper is to provide an overview of the bridge aesthetic and visual quality assessment methods and criteria.

  18. Building large mosaics of confocal edomicroscopic images using visual servoing.

    PubMed

    Rosa, Benoît; Erden, Mustafa Suphi; Vercauteren, Tom; Herman, Benoît; Szewczyk, Jérôme; Morel, Guillaume

    2013-04-01

    Probe-based confocal laser endomicroscopy provides real-time microscopic images of tissues contacted by a small probe that can be inserted in vivo through a minimally invasive access. Mosaicking consists in sweeping the probe in contact with a tissue to be imaged while collecting the video stream, and process the images to assemble them in a large mosaic. While most of the literature in this field has focused on image processing, little attention has been paid so far to the way the probe motion can be controlled. This is a crucial issue since the precision of the probe trajectory control drastically influences the quality of the final mosaic. Robotically controlled motion has the potential of providing enough precision to perform mosaicking. In this paper, we emphasize the difficulties of implementing such an approach. First, probe-tissue contacts generate deformations that prevent from properly controlling the image trajectory. Second, in the context of minimally invasive procedures targeted by our research, robotic devices are likely to exhibit limited quality of the distal probe motion control at the microscopic scale. To cope with these problems visual servoing from real-time endomicroscopic images is proposed in this paper. It is implemented on two different devices (a high-accuracy industrial robot and a prototype minimally invasive device). Experiments on different kinds of environments (printed paper and ex vivo tissues) show that the quality of the visually servoed probe motion is sufficient to build mosaics with minimal distortion in spite of disturbances.

  19. Image resolution enhancement via image restoration using neural network

    NASA Astrophysics Data System (ADS)

    Zhang, Shuangteng; Lu, Yihong

    2011-04-01

    Image super-resolution aims to obtain a high-quality image at a resolution that is higher than that of the original coarse one. This paper presents a new neural network-based method for image super-resolution. In this technique, the super-resolution is considered as an inverse problem. An observation model that closely follows the physical image acquisition process is established to solve the problem. Based on this model, a cost function is created and minimized by a Hopfield neural network to produce high-resolution images from the corresponding low-resolution ones. Not like some other single frame super-resolution techniques, this technique takes into consideration point spread function blurring as well as additive noise and therefore generates high-resolution images with more preserved or restored image details. Experimental results demonstrate that the high-resolution images obtained by this technique have a very high quality in terms of PSNR and visually look more pleasant.

  20. Visual function and quality of life among visually impaired and cataract operated adults. The Pakistan National Blindness and Visual Impairment Survey.

    PubMed

    Taylor, Amy E; Shah, Shaheen P; Gilbert, Clare E; Jadoon, Mohammad Z; Bourne, Rupert R A; Dineen, Brendan; Johnson, Gordon J; Khan, Mohammad D

    2008-01-01

    To assess visual functioning and quality of life in a representative sample of normally sighted, visually impaired and cataract operated individuals aged >or= 30 years in Pakistan. As part of the Pakistan National Blindness and Visual Impairment Survey, visual functioning (VF) and quality of life (QOL) questionnaires were administered to participants with presenting visual acuity less than 6/60 in either eye, aphakes/pseudophakes and a phakic sample with normal acuity (>or= 6/12 both eyes). Of 16,507 adults included in the survey, 2329 questionnaires were administered. There were strong correlations between visual acuity and VF/QOL. Mean VF and median QOL scores in normally sighted phakic individuals were 81.1 and 88.9, respectively, but were only 34.8 and 64.9 in blind unoperated individuals. In the cataract operated population overall mean VF and median QOL scores were 49.3 and 75.0. Both VF and QOL scores were lower in operated individuals than unoperated individuals (p < 0.001). Among operated individuals, rural dwelling and illiteracy were associated with lower VF and QOL scores (p all < 0.02). Although in multivariable analysis bilateral pseudophakes had similar VF scores to bilateral aphakes they had significantly better QOL scores (p = 0.001). Cataract surgery in Pakistan has not led to VF and QOL scores equivalent to those in unoperated individuals with the same levels of visual acuity. The higher proportion of intraocular lens surgery in recent years is likely to improve QOL following cataract surgery. Further focus is needed on rural and illiterate populations, to ensure that they achieve comparable VF/QOL outcomes following surgery.

  1. Memory colours and colour quality evaluation of conventional and solid-state lamps.

    PubMed

    Smet, Kevin A G; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2010-12-06

    A colour quality metric based on memory colours is presented. The basic idea is simple. The colour quality of a test source is evaluated as the degree of similarity between the colour appearance of a set of familiar objects and their memory colours. The closer the match, the better the colour quality. This similarity was quantified using a set of similarity distributions obtained by Smet et al. in a previous study. The metric was validated by calculating the Pearson and Spearman correlation coefficients between the metric predictions and the visual appreciation results obtained in a validation experiment conducted by the authors as well those obtained in two independent studies. The metric was found to correlate well with the visual appreciation of the lighting quality of the sources used in the three experiments. Its performance was also compared with that of the CIE colour rendering index and the NIST colour quality scale. For all three experiments, the metric was found to be significantly better at predicting the correct visual rank order of the light sources (p < 0.1).

  2. Multivariate analysis and visualization of soil quality data for no-till systems.

    PubMed

    Villamil, M B; Miguez, F E; Bollero, G A

    2008-01-01

    To evidence the multidimensionality of the soil quality concept, we propose the use of data visualization as a tool for exploratory data analyses, model building, and diagnostics. Our objective was to establish the best edaphic indicators for assessing soil quality in four no-till systems with regard to functioning as a medium for crop production and nutrient cycling across two Illinois locations. The compared situations were no-till corn-soybean rotations including either winter fallowing (C/S) or cover crops of rye (Secale cereale; C-R/S-R), hairy vetch (Vicia villosa; C-R/S-V), or their mixture (C-R/S-VR). The dataset included the variables bulk density (BD), penetration resistance (PR), water aggregate stability (WAS), soil reaction (pH), and the contents of soil organic matter (SOM), total nitrogen (TN), soil nitrates (NO(3)-N), and available phosphorus (P). Interactive data visualization along with canonical discriminant analysis (CDA) allowed us to show that WAS, BD, and the contents of P, TN, and SOM have the greatest potential as soil quality indicators in no-till systems in Illinois. It was more difficult to discriminate among WCC rotations than to separate these from C/S, considerably inflating the error rate associated with CDA. We predict that observations of no-till C/S will be classified correctly 51% of the time, while observations of no-till WCC rotations will be classified correctly 74% of the time. High error rates in CDA underscore the complexity of no-till systems and the need in this area for more long-term studies with larger datasets to increase accuracy to acceptable levels.

  3. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    PubMed

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p < 0.05). Only the utility scores measured with RS were significantly correlated with the composite OSDI score, "environmental trigger" and "eye discomfort" section scores (p < 0.05). RS is more sensitive than TTO and SG for the evaluation of altered quality of life due to dry eye symptoms.

  4. Monitoring Processes in Visual Search Enhanced by Professional Experience: The Case of Orange Quality-Control Workers

    PubMed Central

    Visalli, Antonino; Vallesi, Antonino

    2018-01-01

    Visual search tasks have often been used to investigate how cognitive processes change with expertise. Several studies have shown visual experts' advantages in detecting objects related to their expertise. Here, we tried to extend these findings by investigating whether professional search experience could boost top-down monitoring processes involved in visual search, independently of advantages specific to objects of expertise. To this aim, we recruited a group of quality-control workers employed in citrus farms. Given the specific features of this type of job, we expected that the extensive employment of monitoring mechanisms during orange selection could enhance these mechanisms even in search situations in which orange-related expertise is not suitable. To test this hypothesis, we compared performance of our experimental group and of a well-matched control group on a computerized visual search task. In one block the target was an orange (expertise target) while in the other block the target was a Smurfette doll (neutral target). The a priori hypothesis was to find an advantage for quality-controllers in those situations in which monitoring was especially involved, that is, when deciding the presence/absence of the target required a more extensive inspection of the search array. Results were consistent with our hypothesis. Quality-controllers were faster in those conditions that extensively required monitoring processes, specifically, the Smurfette-present and both target-absent conditions. No differences emerged in the orange-present condition, which resulted to mainly rely on bottom-up processes. These results suggest that top-down processes in visual search can be enhanced through immersive real-life experience beyond visual expertise advantages. PMID:29497392

  5. The Association Between Visual Assessment of Quality of Movement and Three-Dimensional Analysis of Pelvis, Hip, and Knee Kinematics During a Lateral Step Down Test.

    PubMed

    Rabin, Alon; Portnoy, Sigal; Kozol, Zvi

    2016-11-01

    Rabin, A, Portnoy, S, and Kozol, Z. The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test. J Strength Cond Res 30(11): 3204-3211, 2016-Altered movement patterns including contralateral pelvic drop, increased hip adduction, knee abduction, and external rotation have been previously implicated in several lower extremity pathologies. Although various methods exist for assessing movement patterns, real-time visual observation is the most readily available method. The purpose of this study was to determine whether differing visual ratings of trunk, pelvis, and knee alignment, as well as overall quality of movement, are associated with differences in 3-dimensional trunk, pelvis, hip, or knee kinematics during a lateral step down test. Trunk, pelvis, and knee alignment of 30 healthy participants performing the lateral step down were visually rated as "good" or "faulty" based on previously established criteria. An additional categorization of overall quality of movement as either good or moderate was performed based on the aggregate score of each individual rating criterion. Three-dimensional motion analysis of trunk, pelvis, hip, and knee kinematics was simultaneously performed. A faulty pelvis alignment displayed a greater peak contralateral pelvic drop (effect size [ES], 1.65; p < 0.01) and a greater peak hip adduction (ES: 1.04, p = 0.01) compared with participants with a good pelvis alignment. Participants with a faulty knee alignment displayed greater peak knee external rotation compared with participants with a good knee alignment (ES, 0.78; p = 0.02). Participants with an overall moderate quality of movement displayed increased peak contralateral pelvic drop (ES, 1.07; p = 0.01) and peak knee external rotation (ES, 0.72; p = 0.04) compared with those with an overall good quality of movement. Visual rating of quality of movement during a lateral step down test, as performed by an experienced physical therapist, is associated with differences in several kinematics previously implicated in various pathologies.

  6. The effect of step stool use and provider height on CPR quality during pediatric cardiac arrest: A simulation-based multicentre study.

    PubMed

    Cheng, Adam; Lin, Yiqun; Nadkarni, Vinay; Wan, Brandi; Duff, Jonathan; Brown, Linda; Bhanji, Farhan; Kessler, David; Tofil, Nancy; Hecker, Kent; Hunt, Elizabeth A

    2018-01-01

    We aimed to explore whether a) step stool use is associated with improved cardiopulmonary resuscitation (CPR) quality; b) provider adjusted height is associated with improved CPR quality; and if associations exist, c) determine whether just-in-time (JIT) CPR training and/or CPR visual feedback attenuates the effect of height and/or step stool use on CPR quality. We analysed data from a trial of simulated cardiac arrests with three study arms: No intervention; CPR visual feedback; and JIT CPR training. Step stool use was voluntary. We explored the association between 1) step stool use and CPR quality, and 2) provider adjusted height and CPR quality. Adjusted height was defined as provider height + 23 cm (if step stool was used). Below-average height participants were ≤ gender-specific average height; the remainder were above average height. We assessed for interaction between study arm and both adjusted height and step stool use. One hundred twenty-four subjects participated; 1,230 30-second epochs of CPR were analysed. Step stool use was associated with improved compression depth in below-average (female, p=0.007; male, p<0.001) and above-average (female, p=0.001; male, p<0.001) height providers. There is an association between adjusted height and compression depth (p<0.001). Visual feedback attenuated the effect of height (p=0.025) on compression depth; JIT training did not (p=0.918). Visual feedback and JIT training attenuated the effect of step stool use (p<0.001) on compression depth. Step stool use is associated with improved compression depth regardless of height. Increased provider height is associated with improved compression depth, with visual feedback attenuating the effects of height and step stool use.

  7. Communicating and visualizing data quality through Web Map Services

    NASA Astrophysics Data System (ADS)

    Roberts, Charles; Blower, Jon; Maso, Joan; Diaz, Daniel; Griffiths, Guy; Lewis, Jane

    2014-05-01

    The sharing and visualization of environmental data through OGC Web Map Services is becoming increasingly common. However, information about the quality of data is rarely presented. (In this presentation we consider mostly data uncertainty as a measure of quality, although we acknowledge that many other quality measures are relevant to the geoscience community.) In the context of the GeoViQua project (http://www.geoviqua.org) we have developed conventions and tools for using WMS to deliver data quality information. The "WMS-Q" convention describes how the WMS specification can be used to publish quality information at the level of datasets, variables and individual pixels (samples). WMS-Q requires no extensions to the WMS 1.3.0 specification, being entirely backward-compatible. (An earlier version of WMS-Q was published as OGC Engineering Report 12-160.) To complement the WMS-Q convention, we have also developed extensions to the OGC Symbology Encoding (SE) specification, enabling uncertain geoscience data to be portrayed using a variety of visualization techniques. These include contours, stippling, blackening, whitening, opacity, bivariate colour maps, confidence interval triangles and glyphs. There may also be more extensive applications of these methods beyond the visual representation of uncertainty. In this presentation we will briefly describe the scope of the WMS-Q and "extended SE" specifications and then demonstrate the innovations using open-source software based upon ncWMS (http://ncwms.sf.net). We apply the tools to a variety of datasets including Earth Observation data from the European Space Agency's Climate Change Initiative. The software allows uncertain raster data to be shared through Web Map Services, giving the user fine control over data visualization.

  8. A visual grading study for different administered activity levels in bone scintigraphy.

    PubMed

    Gustafsson, Agnetha; Karlsson, Henrik; Nilsson, Kerstin A; Geijer, Håkan; Olsson, Anna

    2015-05-01

    The aim of the study is to assess the administered activity levels versus visual-based image quality using visual grading regression (VGR) including an assessment of the newly stated image criteria for whole-body bone scintigraphy. A total of 90 patients was included and grouped in three levels of administered activity: 400, 500 and 600 MBq. Six clinical image criteria regarding image quality was formulated by experienced nuclear medicine physicians. Visual grading was performed in all images, where three physicians rated the fulfilment of the image criteria on a four-step ordinal scale. The results were analysed using VGR. A count analysis was also made where the total number of counts in both views was registered. The administered activity of 600 MBq gives significantly better image quality than 400 MBq in five of six criteria (P<0·05). Comparing the administered activity of 600 MBq to 500 MBq, four criteria of six show significantly better image quality (P<0·05). The administered activity of 500 MBq gives no significantly better image quality than 400 Mbq (P<0·05). The count analysis shows that none of the three levels of administrated activity fulfil the recommendations by the EANM. There was a significant improvement in perceived image quality using an activity level of 600 MBq compared to lower activity levels in whole-body bone scintigraphy for the gamma camera equipment end set-up used in this study. This type of visual-based grading study seems to be a valuable tool and easy to implement in the clinical environment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Visual Working Memory Cannot Trade Quantity for Quality.

    PubMed

    Ramaty, Ayelet; Luria, Roy

    2018-01-01

    Two main models have been proposed to describe how visual working memory (WM) allocates its capacity: the slot-model and the continuous resource-model. The purpose of the current study was to test a direct prediction of the resource model suggesting that WM can trade-off between the quantity and quality of the encoded information. Previous research reported equivocal results, with studies that failed to find such a trade-off and other studies that reported a trade-off. Following the design of previous studies, in Experiment 1 we replicated this trade-off, by presenting the memory array for 1200 ms. Experiment 2 failed to observe a trade-off between quantity and quality using a memory array interval of 300 ms (a standard interval for visual WM). Experiment 3 again failed to find this trade-off, when reinstating the 1200 ms memory array interval but adding an articulatory suppression manipulation. We argue that while participants can trade quantity for quality, this pattern depends on verbal encoding and transfer to long-term memory processes that were possible to perform only during the long retention interval. When these processes were eliminated, the trade-off disappeared. Thus, we didn't find any evidence that the trade-off between quantity for quality can occur within visual WM.

  10. The Q-Sort method: use in landscape assessment research and landscape planning

    Treesearch

    David G. Pitt; Ervin H. Zube

    1979-01-01

    The assessment of visual quality inherently involves the measurement of perceptual response to landscape. The Q-Sort Method is a psychometric technique which produces reliable and valid interval measurements of people's perceptions of landscape visual quality as depicted in photographs. It is readily understood by participants across a wide range of age groups and...

  11. Effects of Video-Feedback Interaction Training for Professional Caregivers of Children and Adults with Visual and Intellectual Disabilities

    ERIC Educational Resources Information Center

    Damen, S.; Kef, S.; Worm, M.; Janssen, M. J.; Schuengel, C.

    2011-01-01

    Background: Individuals in group homes may experience poor quality of social interaction with their professional caregivers, limiting their quality of life. The video-based Contact programme may help caregivers to improve their interaction with clients. Method: Seventy-two caregivers of 12 individuals with visual and intellectual disabilities…

  12. Changes in Quality of Life in Visually Impaired Patients after Low-Vision Rehabilitation

    ERIC Educational Resources Information Center

    Renieri, Giulia; Pitz, Susanne; Pfeiffer, Norbert; Beutel, Manfred E.; Zwerenz, Rudiger

    2013-01-01

    The objective of the study was to assess the impact of low-vision aids on quality of life. Interviews included a modified version of the National Eye Institute Visual Functioning Questionnaire (Modified German NEI VFQ-25), the Hospital Anxiety and Depression Scale, the Mini-Mental State Examination Blind, and Indicators of the Rehabilitation…

  13. Constructivist-Visual Mind Map Teaching Approach and the Quality of Students' Cognitive Structures

    ERIC Educational Resources Information Center

    Dhindsa, Harkirat S.; Makarimi-Kasim; Anderson, O. Roger

    2011-01-01

    This study compared the effects of a constructivist-visual mind map teaching approach (CMA) and of a traditional teaching approach (TTA) on (a) the quality and richness of students' knowledge structures and (b) TTA and CMA students' perceptions of the extent that a constructivist learning environment (CLE) was created in their classes. The sample…

  14. Why is quality estimation judgment fast? Comparison of gaze control strategies in quality and difference estimation tasks

    NASA Astrophysics Data System (ADS)

    Radun, Jenni; Leisti, Tuomas; Virtanen, Toni; Nyman, Göte; Häkkinen, Jukka

    2014-11-01

    To understand the viewing strategies employed in a quality estimation task, we compared two visual tasks-quality estimation and difference estimation. The estimation was done for a pair of natural images having small global changes in quality. Two groups of observers estimated the same set of images, but with different instructions. One group estimated the difference in quality and the other the difference between image pairs. The results demonstrated the use of different visual strategies in the tasks. The quality estimation was found to include more visual planning during the first fixation than the difference estimation, but afterward needed only a few long fixations on the semantically important areas of the image. The difference estimation used many short fixations. Salient image areas were mainly attended to when these areas were also semantically important. The results support the hypothesis that these tasks' general characteristics (evaluation time, number of fixations, area fixated on) show differences in processing, but also suggest that examining only single fixations when comparing tasks is too narrow a view. When planning a subjective experiment, one must remember that a small change in the instructions might lead to a noticeable change in viewing strategy.

  15. Fly-scan ptychography

    DOE PAGES

    Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.; ...

    2015-03-13

    We report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns. Thus, this approach significantly increases the throughput of ptychography, especially for three-dimensional applications and the visualization of dynamic systems.

  16. The Inclusive Educational Process of Students with Visual Impairments in Spain: An Analysis from the Perspective of Organizations

    ERIC Educational Resources Information Center

    Simon, Cecilia; Echeita, Gerardo; Sandoval, Marta; Lopez, Mauricio

    2010-01-01

    Inclusive education is a complex and multidimensional process that, among other aspirations, tries to foster the rights of every student to obtain a high-quality education. This process focuses on the diversity of needs of all students by increasing participation in learning, cultures, and communities and reducing exclusion within and from…

  17. Artful Dodgers: An Arts Education Research Project in Early Education Settings

    ERIC Educational Resources Information Center

    Hayes, Nóirín; Maguire, Jackie; Corcoran, Lucie; O'Sullivan, Carmel

    2017-01-01

    Artful Dodgers is an arts education project developed by two artists and delivered in two early years settings located in two areas of urban disadvantage. It is a music and visual arts programme designed and implemented with early years teachers of children aged 3-5 years. It explored whether the provision of high-quality arts experiences could…

  18. Vision related quality of life in patients with type 2 diabetes in the EUROCONDOR trial.

    PubMed

    Trento, Marina; Durando, Olga; Lavecchia, Sonia; Charrier, Lorena; Cavallo, Franco; Costa, Miguel Angelo; Hernández, Cristina; Simó, Rafael; Porta, Massimo

    2017-07-01

    To evaluate vision related quality of life in the patients enrolled in The European Consortium for the Early Treatment of Diabetic Retinopathy, a clinical trial on prevention of diabetic retinopathy. Four-hundred-forty-nine patients, 153 women, with type 2 Diabetes and no or mild diabetic retinopathy were enrolled in a 2-year multicenter randomized controlled trial. The 25-item National Eye Institute Visual Functioning Questionnaire was used to explore 12 subscales of vision related quality of life. The patients were 62.8 ± 6.7 years old and had 11.1 ± 5.6 years known disease duration. Diabetic retinopathy was absent in 193 (43.0 %) and mild in 256 (57.0 %). Patients without diabetic retinopathy were older, had shorter diabetes duration and used less insulin and glucose-lowering agents but did not differ by gender, best corrected visual acuity or any subscale, except vision specific mental health and vision specific role difficulties. Patients with reduced retinal thickness at the ganglion cell layer (n = 36) did not differ for diabetic retinopathy but were older, had lower best corrected visual acuity and worse scores for ocular pain, color vision and peripheral vision. On multivariable analysis, worse scores for general vision remained associated with reduced retinal thickness, diabetes duration and best corrected visual acuity, and scores for visual specific mental health with diabetic retinopathy and lower best corrected visual acuity. Visual specific role difficulties were only associated with reduced best corrected visual acuity. Scores for driving decreased among females, with worsening of Hemoglobin A1c and best corrected visual acuity. Color vision depended only on reduced retinal thickness, and peripheral vision on both reduced thickness and best corrected visual acuity. The National Eye Institute Visual Functioning Questionnaire could detect subtle changes in patients' perception of visual function, despite absent/minimal diabetic retinopathy.

  19. Kalai-Smorodinsky bargaining solution for optimal resource allocation over wireless DS-CDMA visual sensor networks

    NASA Astrophysics Data System (ADS)

    Pandremmenou, Katerina; Kondi, Lisimachos P.; Parsopoulos, Konstantinos E.

    2012-01-01

    Surveillance applications usually require high levels of video quality, resulting in high power consumption. The existence of a well-behaved scheme to balance video quality and power consumption is crucial for the system's performance. In the present work, we adopt the game-theoretic approach of Kalai-Smorodinsky Bargaining Solution (KSBS) to deal with the problem of optimal resource allocation in a multi-node wireless visual sensor network (VSN). In our setting, the Direct Sequence Code Division Multiple Access (DS-CDMA) method is used for channel access, while a cross-layer optimization design, which employs a central processing server, accounts for the overall system efficacy through all network layers. The task assigned to the central server is the communication with the nodes and the joint determination of their transmission parameters. The KSBS is applied to non-convex utility spaces, efficiently distributing the source coding rate, channel coding rate and transmission powers among the nodes. In the underlying model, the transmission powers assume continuous values, whereas the source and channel coding rates can take only discrete values. Experimental results are reported and discussed to demonstrate the merits of KSBS over competing policies.

  20. [Surgical management of ankylosing spondylitis (Bechterew's disease)].

    PubMed

    Allouch, H; Shousha, M; Böhm, H

    2017-12-01

    Ankylosing spondylitis is an inflammatory rheumatic disease that is often associated with back pain and restricted spinal movement. In the later stages of the disease, complete ossification of the entire spine and severe deformity can occur, often resulting in a marked reduction in quality of life and an increased risk of loss of independence due to diminished visual field. Patients with ankylosing spondylitis are at greater risk of spinal fractures. These are generally complex fractures associated with high morbidity and mortality; in addition, neurological deficits are not unusual. Conventional radiological diagnosis is often insufficient to establish a diagnosis. Conservative treatment of fractures of the spine in this patient group is unsatisfactory. Surgical procedures, if necessary combined with decompression, are often the preferred treatment of choice in the fractured or malaligned ankylosed spine. Rebalancing of the sagittal profile with normalization of the visual axis and an improvement of quality of life is achieved through corrective osteotomies. Despite the high rate of complications, long-term results following spinal surgery in patients with ankylosing spondylitis are good. Minimally invasive surgery is appropriate for a further reduction in the complication rate. Meticulous preoperative planning is essential in the treatment of patients with ankylosing spondylitis.

  1. Piloted Simulation Assessment of a High-Speed Civil Transport Configuration. [conducted with the Langley six-degree-of-freedom Visual Motion Simulator

    NASA Technical Reports Server (NTRS)

    Jackson, E. Bruce; Raney, David L.; Glaab, Louis J.; Derry, Stephen D.

    2002-01-01

    An assessment of a proposed configuration of a high-speed civil transport was conducted by using NASA and industry research pilots. The assessment was conducted to evaluate operational aspects of the configuration from a pilot's perspective, with the primary goal being to identify potential deficiencies in the configuration. The configuration was evaluated within and at the limits of the design operating envelope to determine the suitability of the configuration to maneuver in a typical mission as well as in emergency or envelope-limit conditions. The Cooper-Harper rating scale was used to evaluate the flying qualities of the configuration. A summary flying qualities metric was also calculated. The assessment was performed in the Langley six-degree-of-freedom Visual Motion Simulator. The effect of a restricted cockpit field-of-view due to obstruction by the vehicle nose was not included in this study. Tasks include landings, takeoffs, climbs, descents, overspeeds, coordinated turns, and recoveries from envelope limit excursions. Emergencies included engine failures, loss of stability augmentation, engine inlet unstarts, and emergency descents. Minimum control speeds and takeoff decision, rotation, and safety speeds were also determined.

  2. Vision and quality-of-life.

    PubMed Central

    Brown, G C

    1999-01-01

    OBJECTIVE: To determine the relationship of visual acuity loss to quality of life. DESIGN: Three hundred twenty-five patients with visual loss to a minimum of 20/40 or greater in at least 1 eye were interviewed in a standardized fashion using a modified VF-14, questionnaire. Utility values were also obtained using both the time trade-off and standard gamble methods of utility assessment. MAIN OUTCOME MEASURES: Best-corrected visual acuity was correlated with the visual function score on the modified VF-14 questionnaire, as well as with utility values obtained using both the time trade-off and standard gamble methods. RESULTS: Decreasing levels of vision in the eye with better acuity correlated directly with decreasing visual function scores on the modified VF-14 questionnaire, as did decreasing utility values using the time trade-off method of utility evaluation. The standard gamble method of utility evaluation was not as directly correlated with vision as the time trade-off method. Age, level of education, gender, race, length of time of visual loss, and the number of associated systemic comorbidities did not significantly affect the time trade-off utility values associated with visual loss in the better eye. The level of reduced vision in the better eye, rather than the specific disease process causing reduced vision, was related to mean utility values. The average person with 20/40 vision in the better seeing eye was willing to trade 2 of every 10 years of life in return for perfect vision (utility value of 0.8), while the average person with counting fingers vision in the better eye was willing to trade approximately 5 of every 10 remaining years of life (utility value of 0.52) in return for perfect vision. CONCLUSIONS: The time trade-off method of utility evaluation appears to be an effective method for assessing quality of life associated with visual loss. Time trade-off utility values decrease in direct conjunction with decreasing vision in the better-seeing eye. Unlike the modified VF-14 test and its counterparts, utility values allow the quality of life associated with visual loss to be more readily compared to the quality of life associated with other health (disease) states. This information can be employed for cost-effective analyses that objectively compare evidence-based medicine, patient-based preferences and sound econometric principles across all specialties in health care. PMID:10703139

  3. A Spectral Method for Color Quantitation of a Protein Drug Solution.

    PubMed

    Swartz, Trevor E; Yin, Jian; Patapoff, Thomas W; Horst, Travis; Skieresz, Susan M; Leggett, Gordon; Morgan, Charles J; Rahimi, Kimia; Marhoul, Joseph; Kabakoff, Bruce

    2016-01-01

    Color is an important quality attribute for biotherapeutics. In the biotechnology industry, a visual method is most commonly utilized for color characterization of liquid drug protein solutions. The color testing method is used for both batch release and on stability testing for quality control. Using that method, an analyst visually determines the color of the sample by choosing the closest matching European Pharmacopeia reference color solution. The requirement to judge the best match makes it a subjective method. Furthermore, the visual method does not capture data on hue or chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we describe a quantitative method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. Following color industry standards established by International Commission on Illumination, this method converts a protein solution's visible absorption spectra to L*a*b* color space. Color matching is achieved within the L*a*b* color space, a practice that is already widely used in other industries. The work performed here is to facilitate the adoption and transition for the traditional visual assessment method to a quantitative spectral method. We describe here the algorithm used such that the quantitative spectral method correlates with the currently used visual method. In addition, we provide the L*a*b* values for the European Pharmacopeia reference color solutions required for the quantitative method. We have determined these L*a*b* values by gravimetrically preparing and measuring multiple lots of the reference color solutions. We demonstrate that the visual assessment and the quantitative spectral method are comparable using both low- and high-concentration antibody solutions and solutions with varying turbidity. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. The details of the spectral quantitative method are described. A comparison between the visual assessment method and spectral quantitative method is presented. This study supports the transition to a quantitative spectral method from the visual assessment method for quality testing of protein solutions. © PDA, Inc. 2016.

  4. Validation of the Passenger Ride Quality Apparatus (PRQA) for simulation of aircraft motions for ride-quality research

    NASA Technical Reports Server (NTRS)

    Bigler, W. B., II

    1977-01-01

    The NASA passenger ride quality apparatus (PRQA), a ground based motion simulator, was compared to the total in flight simulator (TIFS). Tests were made on PRQA with varying stimuli: motions only; motions and noise; motions, noise, and visual; and motions and visual. Regression equations for the tests were obtained and subsequent t-testing of the slopes indicated that ground based simulator tests produced comfort change rates similar to actual flight data. It was recommended that PRQA be used in the ride quality program for aircraft and that it be validated for other transportation modes.

  5. Image quality assessment by preprocessing and full reference model combination

    NASA Astrophysics Data System (ADS)

    Bianco, S.; Ciocca, G.; Marini, F.; Schettini, R.

    2009-01-01

    This paper focuses on full-reference image quality assessment and presents different computational strategies aimed to improve the robustness and accuracy of some well known and widely used state of the art models, namely the Structural Similarity approach (SSIM) by Wang and Bovik and the S-CIELAB spatial-color model by Zhang and Wandell. We investigate the hypothesis that combining error images with a visual attention model could allow a better fit of the psycho-visual data of the LIVE Image Quality assessment Database Release 2. We show that the proposed quality assessment metric better correlates with the experimental data.

  6. Coaching positively influences the effects of working memory training on visual working memory as well as mathematical ability.

    PubMed

    Nelwan, Michel; Vissers, Constance; Kroesbergen, Evelyn H

    2018-05-01

    The goal of the present study was to test whether the amount of coaching influenced the results of working memory training on both visual and verbal working memory. Additionally, the effects of the working memory training on the amount of progress after specific training in mathematics were evaluated. In this study, 23 children between 9 and 12 years of age with both attentional and mathematical difficulties participated in a working memory training program with a high amount of coaching, while another 25 children received no working memory training. Results of these groups were compared to 21 children who completed the training with a lower amount of coaching. The quality of working memory, as well as mathematic skills, were measured three times using untrained transfer tasks. Bayesian statistics were used to test informative hypotheses. After receiving working memory training, the highly coached group performed better than the group that received less coaching on visual working memory and mathematics, but not on verbal working memory. The highly coached group retained their advantage in mathematics, even though the effect on visual working memory decreased. However, no added effect of working memory training was found on the learning curve during mathematical training. Moreover, the less-coached group was outperformed by the group that did not receive working memory training, both in visual working memory and mathematics. These results suggest that motivation and proper coaching might be crucial for ensuring compliance and effects of working memory training, and that far transfer might be possible. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Filming the invisible - time-resolved visualization of compressible flows

    NASA Astrophysics Data System (ADS)

    Kleine, H.

    2010-04-01

    Essentially all processes in gasdynamics are invisible to the naked eye as they occur in a transparent medium. The task to observe them is further complicated by the fact that most of these processes are also transient, often with characteristic times that are considerably below the threshold of human perception. Both difficulties can be overcome by combining visualization methods that reveal changes in the transparent medium, and high-speed photography techniques that “stop” the motion of the flow. The traditional approach is to reconstruct a transient process from a series of single images, each taken in a different experiment at a different instant. This approach, which is still widely used today, can only be expected to give reliable results when the process is reproducible. Truly time-resolved visualization, which yields a sequence of flow images in a single experiment, has been attempted for more than a century, but many of the developed camera systems were characterized by a high level of complexity and limited quality of the results. Recent advances in digital high-speed photography have changed this situation and have provided the tools to investigate, with relative ease and in sufficient detail, the true development of a transient flow with characteristic time scales down to one microsecond. This paper discusses the potential and the limitations one encounters when using density-sensitive visualization techniques in time-resolved mode. Several examples illustrate how this approach can reveal and explain a number of previously undetected phenomena in a variety of highly transient compressible flows. It is demonstrated that time-resolved visualization offers numerous advantages which normally outweigh its shortcomings, mainly the often-encountered loss in resolution. Apart from the capability to track the location and/or shape of flow features in space and time, adequate time-resolved visualization allows one to observe the development of deliberately introduced near-isentropic perturbation wavelets. This new diagnostic tool can be used to qualitatively and quantitatively determine otherwise inaccessible thermodynamic properties of a compressible flow.

  8. Setting visual pre-placement testing in a technology manufacturing environment.

    PubMed

    Gowan, Nancy J

    2014-01-01

    Every day we use our eyes to perform activities of daily living and work. Aging changes as well as health conditions can impact an individual's visual function, making it more difficult to accurately perform work activities. Occupational therapists work closely with optometrists and employers to develop ways to accommodate for these changes so that the employee can continue to perform the work tasks. This manuscript outlines a case study of systematically developing visual demands analyses and pre-placement vision screening assessment protocols for individuals completing quality inspection positions. When the vision screening was completed, it was discovered that over 20% of the employees had visual deficits that were correctable. This screening process yielded improved quality results but also identification of previously undetected visual deficits. Further development of vision screening in the workplace is supported.

  9. Safety and EEG data quality of concurrent high-density EEG and high-speed fMRI at 3 Tesla

    PubMed Central

    Foged, Mette Thrane; Lindberg, Ulrich; Vakamudi, Kishore; Larsson, Henrik B. W.; Pinborg, Lars H.; Kjær, Troels W.; Fabricius, Martin; Svarer, Claus; Ozenne, Brice; Thomsen, Carsten; Beniczky, Sándor; Posse, Stefan

    2017-01-01

    Purpose Concurrent EEG and fMRI is increasingly used to characterize the spatial-temporal dynamics of brain activity. However, most studies to date have been limited to conventional echo-planar imaging (EPI). There is considerable interest in integrating recently developed high-speed fMRI methods with high-density EEG to increase temporal resolution and sensitivity for task-based and resting state fMRI, and for detecting interictal spikes in epilepsy. In the present study using concurrent high-density EEG and recently developed high-speed fMRI methods, we investigate safety of radiofrequency (RF) related heating, the effect of EEG on cortical signal-to-noise ratio (SNR) in fMRI, and assess EEG data quality. Materials and methods The study compared EPI, multi-echo EPI, multi-band EPI and multi-slab echo-volumar imaging pulse sequences, using clinical 3 Tesla MR scanners from two different vendors that were equipped with 64- and 256-channel MR-compatible EEG systems, respectively, and receive only array head coils. Data were collected in 11 healthy controls (3 males, age range 18–70 years) and 13 patients with epilepsy (8 males, age range 21–67 years). Three of the healthy controls were scanned with the 256-channel EEG system, the other subjects were scanned with the 64-channel EEG system. Scalp surface temperature, SNR in occipital cortex and head movement were measured with and without the EEG cap. The degree of artifacts and the ability to identify background activity was assessed by visual analysis by a trained expert in the 64 channel EEG data (7 healthy controls, 13 patients). Results RF induced heating at the surface of the EEG electrodes during a 30-minute scan period with stable temperature prior to scanning did not exceed 1.0° C with either EEG system and any of the pulse sequences used in this study. There was no significant decrease in cortical SNR due to the presence of the EEG cap (p > 0.05). No significant differences in the visually analyzed EEG data quality were found between EEG recorded during high-speed fMRI and during conventional EPI (p = 0.78). Residual ballistocardiographic artifacts resulted in 58% of EEG data being rated as poor quality. Conclusion This study demonstrates that high-density EEG can be safely implemented in conjunction with high-speed fMRI and that high-speed fMRI does not adversely affect EEG data quality. However, the deterioration of the EEG quality due to residual ballistocardiographic artifacts remains a significant constraint for routine clinical applications of concurrent EEG-fMRI. PMID:28552957

  10. Practical, Real-Time, and Robust Watermarking on the Spatial Domain for High-Definition Video Contents

    NASA Astrophysics Data System (ADS)

    Kim, Kyung-Su; Lee, Hae-Yeoun; Im, Dong-Hyuck; Lee, Heung-Kyu

    Commercial markets employ digital right management (DRM) systems to protect valuable high-definition (HD) quality videos. DRM system uses watermarking to provide copyright protection and ownership authentication of multimedia contents. We propose a real-time video watermarking scheme for HD video in the uncompressed domain. Especially, our approach is in aspect of practical perspectives to satisfy perceptual quality, real-time processing, and robustness requirements. We simplify and optimize human visual system mask for real-time performance and also apply dithering technique for invisibility. Extensive experiments are performed to prove that the proposed scheme satisfies the invisibility, real-time processing, and robustness requirements against video processing attacks. We concentrate upon video processing attacks that commonly occur in HD quality videos to display on portable devices. These attacks include not only scaling and low bit-rate encoding, but also malicious attacks such as format conversion and frame rate change.

  11. Health-Related Quality of Life in Chronic Pruritus: An Analysis Related to Disease Etiology, Clinical Skin Conditions and Itch Intensity.

    PubMed

    Warlich, Benjamin; Fritz, Fleur; Osada, Nani; Bruland, Philipp; Stumpf, Astrid; Schneider, Gudrun; Dugas, Martin; Pfleiderer, Bettina; Ständer, Sonja

    2015-01-01

    It is unknown if health-related quality of life (HRQoL) differs between diseases associated with chronic pruritus (CP). To analyze HRQoL in relation to age, gender, skin lesions (primary vs. scratch-induced secondary) and itch intensity. Consecutive patients of our itch clinic were assessed with the Dermatology Life Quality Index (DLQI) and visual analogue scale (VAS). In 510 CP patients (282 females; median age, 61.4 years), DLQI scores and VAS values were highly correlated, irrespective of the type of skin lesion. Overall, women had a lower HRQoL compared to men (females: 10.7 ± 6.7, males: 8.9 ± 6.7), but female gender was only associated with worse quality of life in patients <65 years old. HRQoL impairment in CP is highly influenced by pruritus intensity but not to the visible skin lesion or underlying cause. With limitations to item bias, DLQI is a suitable instrument for estimating quality of life impairment by CP. © 2015 S. Karger AG, Basel.

  12. Negative emotion boosts quality of visual working memory representation.

    PubMed

    Xie, Weizhen; Zhang, Weiwei

    2016-08-01

    Negative emotion impacts a variety of cognitive processes, including working memory (WM). The present study investigated whether negative emotion modulated WM capacity (quantity) or resolution (quality), 2 independent limits on WM storage. In Experiment 1, observers tried to remember several colors over 1-s delay and then recalled the color of a randomly picked memory item by clicking a best-matching color on a continuous color wheel. On each trial, before the visual WM task, 1 of 3 emotion conditions (negative, neutral, or positive) was induced by having observers to rate the valence of an International Affective Picture System image. Visual WM under negative emotion showed enhanced resolution compared with neutral and positive conditions, whereas the number of retained representations was comparable across the 3 emotion conditions. These effects were generalized to closed-contour shapes in Experiment 2. To isolate the locus of these effects, Experiment 3 adopted an iconic memory version of the color recall task by eliminating the 1-s retention interval. No significant change in the quantity or quality of iconic memory was observed, suggesting that the resolution effects in the first 2 experiments were critically dependent on the need to retain memory representations over a short period of time. Taken together, these results suggest that negative emotion selectively boosts visual WM quality, supporting the dissociable nature quantitative and qualitative aspects of visual WM representation. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Cortical reinstatement and the confidence and accuracy of source memory.

    PubMed

    Thakral, Preston P; Wang, Tracy H; Rugg, Michael D

    2015-04-01

    Cortical reinstatement refers to the overlap between neural activity elicited during the encoding and the subsequent retrieval of an episode, and is held to reflect retrieved mnemonic content. Previous findings have demonstrated that reinstatement effects reflect the quality of retrieved episodic information as this is operationalized by the accuracy of source memory judgments. The present functional magnetic resonance imaging (fMRI) study investigated whether reinstatement-related activity also co-varies with the confidence of accurate source judgments. Participants studied pictures of objects along with their visual or spoken names. At test, they first discriminated between studied and unstudied pictures and then, for each picture judged as studied, they also judged whether it had been paired with a visual or auditory name, using a three-point confidence scale. Accuracy of source memory judgments- and hence the quality of the source-specifying information--was greater for high than for low confidence judgments. Modality-selective retrieval-related activity (reinstatement effects) also co-varied with the confidence of the corresponding source memory judgment. The findings indicate that the quality of the information supporting accurate judgments of source memory is indexed by the relative magnitude of content-selective, retrieval-related neural activity. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Content-based multiple bitstream image transmission over noisy channels.

    PubMed

    Cao, Lei; Chen, Chang Wen

    2002-01-01

    In this paper, we propose a novel combined source and channel coding scheme for image transmission over noisy channels. The main feature of the proposed scheme is a systematic decomposition of image sources so that unequal error protection can be applied according to not only bit error sensitivity but also visual content importance. The wavelet transform is adopted to hierarchically decompose the image. The association between the wavelet coefficients and what they represent spatially in the original image is fully exploited so that wavelet blocks are classified based on their corresponding image content. The classification produces wavelet blocks in each class with similar content and statistics, therefore enables high performance source compression using the set partitioning in hierarchical trees (SPIHT) algorithm. To combat the channel noise, an unequal error protection strategy with rate-compatible punctured convolutional/cyclic redundancy check (RCPC/CRC) codes is implemented based on the bit contribution to both peak signal-to-noise ratio (PSNR) and visual quality. At the receiving end, a postprocessing method making use of the SPIHT decoding structure and the classification map is developed to restore the degradation due to the residual error after channel decoding. Experimental results show that the proposed scheme is indeed able to provide protection both for the bits that are more sensitive to errors and for the more important visual content under a noisy transmission environment. In particular, the reconstructed images illustrate consistently better visual quality than using the single-bitstream-based schemes.

  15. A method for improved visual landscape compatibility of mobile home park

    Treesearch

    Daniel R. Jones

    1979-01-01

    This paper is a description of a research effort directed to improving the visual image of mobile home parks in the landscape. The study is an application of existing methodologies for measuring scenic quality and visual landscape compatibility to an unsolved problem. The paper summarizes two major areas of investigation: regional location factors based on visual...

  16. Prevalence and Causes of Visual Loss Among the Indigenous Peoples of the World: A Systematic Review.

    PubMed

    Foreman, Joshua; Keel, Stuart; van Wijngaarden, Peter; Bourne, Rupert A; Wormald, Richard; Crowston, Jonathan; Taylor, Hugh R; Dirani, Mohamed

    2018-05-01

    Studies have documented a higher disease burden in indigenous compared with nonindigenous populations, but no global data on the epidemiology of visual loss in indigenous peoples are available. A systematic review of literature on visual loss in the world's indigenous populations could identify major gaps and inform interventions to reduce their burden of visual loss. To conduct a systematic review on the prevalence and causes of visual loss among the world's indigenous populations. A search of databases and alternative sources identified literature on the prevalence and causes of visual loss (visual impairment and blindness) and eye diseases in indigenous populations. Studies from January 1, 1990, through August 1, 2017, that included clinical eye examinations of indigenous participants and, where possible, compared findings with those of nonindigenous populations were included. Methodologic quality of studies was evaluated to reveal gaps in the literature. Limited data were available worldwide. A total of 85 articles described 64 unique studies from 24 countries that examined 79 598 unique indigenous participants. Nineteen studies reported comparator data on 42 085 nonindigenous individuals. The prevalence of visual loss was reported in 13 countries, with visual impairment ranging from 0.6% in indigenous Australian children to 48.5% in native Tibetans 50 years or older. Uncorrected refractive error was the main cause of visual impairment (21.0%-65.1%) in 5 of 6 studies that measured presenting visual acuity. Cataract was the main cause of visual impairment in all 6 studies measuring best-corrected acuity (25.4%-72.2%). Cataract was the leading cause of blindness in 13 studies (32.0%-79.2%), followed by uncorrected refractive error in 2 studies (33.0% and 35.8%). Most countries with indigenous peoples do not have data on the burden of visual loss in these populations. Although existing studies vary in methodologic quality and reliability, they suggest that most visual loss in indigenous populations is avoidable. Improvements in quality and frequency of research into the eye health of indigenous communities appear to be required, and coordinated eye care programs should be implemented to specifically target the indigenous peoples of the world.

  17. A daily skincare regimen with a unique ceramide and filaggrin formulation rapidly improves chronic xerosis, pruritus, and quality of life in older adults.

    PubMed

    Chang, Anne Lynn S; Chen, Suephy C; Osterberg, Lars; Brandt, Staci; von Grote, Erika C; Meckfessel, Matthew H

    A skin care regimen which significantly improved atopic dermatitis and pruritus was evaluated for its efficacy and acceptability in senior subjects diagnosed with xerosis who also suffer from pruritus. This was an open-label, single-center study, designed to evaluate the daily use of a skin care regimen for 15 days. Assessments were made at baseline, day 8 and day 15 for visual skin dryness, transepidermal water loss (TEWL), hydration, desquamation, subject-perceived itch and quality of life (QoL). Twenty-five subjects, ages 60-73 years, had significantly improved skin visual dryness, hydration, desquamation, itch and QoL at days 8 and 15, relative to baseline (P < .05). TEWL was improved, though not significantly. Subjects expressed a high degree of satisfaction with the results. This regimen provides geriatric patients with an easily incorporated skin routine to help improve a common symptom of aging skin which negatively affects QoL. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A semi-blind logo watermarking scheme for color images by comparison and modification of DFT coefficients

    NASA Astrophysics Data System (ADS)

    Kusyk, Janusz; Eskicioglu, Ahmet M.

    2005-10-01

    Digital watermarking is considered to be a major technology for the protection of multimedia data. Some of the important applications are broadcast monitoring, copyright protection, and access control. In this paper, we present a semi-blind watermarking scheme for embedding a logo in color images using the DFT domain. After computing the DFT of the luminance layer of the cover image, the magnitudes of DFT coefficients are compared, and modified. A given watermark is embedded in three frequency bands: Low, middle, and high. Our experiments show that the watermarks extracted from the lower frequencies have the best visual quality for low pass filtering, adding Gaussian noise, JPEG compression, resizing, rotation, and scaling, and the watermarks extracted from the higher frequencies have the best visual quality for cropping, intensity adjustment, histogram equalization, and gamma correction. Extractions from the fragmented and translated image are identical to extractions from the unattacked watermarked image. The collusion and rewatermarking attacks do not provide the hacker with useful tools.

  19. A complete investigation of monocular and binocular functions in clinically treated amblyopia.

    PubMed

    Zhao, Wuxiao; Jia, Wu-Li; Chen, Ge; Luo, Yan; Lin, Borong; He, Qing; Lu, Zhong-Lin; Li, Min; Huang, Chang-Bing

    2017-09-06

    The gold standard of a successful amblyopia treatment is full recovery of visual acuity (VA) in the amblyopic eye, but there has been no systematic study on both monocular and binocular visual functions. In this research, we aimed to quantify visual qualities with a variety of perceptual tasks in subjects with treated amblyopia. We found near stereoacuity and pAE dominance in binocular rivalry in "treated" amblyopia were largely comparable to those of normal subjects. CSF of the pAE remained deficient in high spatial frequencies. The binocular contrast summation ratio is significantly lower than normal standard. The interocular balance point is 34%, indicating that contrast in pAE is much less effective as the same contrast in pFE in binocular phase combination. Although VA, stereoacuity and binocular rivalry at low spatial frequency in treated amblyopes were normal or nearly normal, the pAE remained "lazy" in high frequency domain, binocular contrast summation, and interocular phase combination. Our results suggest that structured monocular and binocular training are necessary to fully recover deficient functions in amblyopia.

  20. Building Virtual Mars

    NASA Astrophysics Data System (ADS)

    Abercrombie, S. P.; Menzies, A.; Goddard, C.

    2017-12-01

    Virtual and augmented reality enable scientists to visualize environments that are very difficult, or even impossible to visit, such as the surface of Mars. A useful immersive visualization begins with a high quality reconstruction of the environment under study. This presentation will discuss a photogrammetry pipeline developed at the Jet Propulsion Laboratory to reconstruct 3D models of the surface of Mars using stereo images sent back to Earth by the Curiosity Mars rover. The resulting models are used to support a virtual reality tool (OnSight) that allows scientists and engineers to visualize the surface of Mars as if they were standing on the red planet. Images of Mars present challenges to existing scene reconstruction solutions. Surface images of Mars are sparse with minimal overlap, and are often taken from extremely different viewpoints. In addition, the specialized cameras used by Mars rovers are significantly different than consumer cameras, and GPS localization data is not available on Mars. This presentation will discuss scene reconstruction with an emphasis on coping with limited input data, and on creating models suitable for rendering in virtual reality at high frame rate.

  1. Visualizing surgical quality data with treemaps.

    PubMed

    Hugine, Akilah L; Guerlain, Stephanie A; Turrentine, Florence E

    2014-09-01

    Treemaps are space-constrained visualizations for displaying hierarchical data structures using nested rectangles. The visualization allows large amounts of data to be examined in one display. The objective of this research was to examine the effects of using treemap visualizations to help surgeons assess surgical quality data from the American College of Surgeons created the National Surgical Quality Improvement Program database in a quick and timely manner. A controlled human subjects experiment was conducted to assess the ability of individuals to make quick and accurate judgments on surgery data by visualizing a treemap, with data hierarchically displayed by surgeon group, surgeon, and patient. Participants were given 20 task questions to complete involving examining the treemap and comparing surgeons' patients based on outcomes (dead or alive) and length of stay days. The outcomes measured were error (incorrect or correct) and task completion time. 120 participants completed 20 task questions for a total of 2400 responses. The main effects of layout and node size were found to be significant for absolute error, P < 0.0505 and P < 0.0185, respectively. The average judgment time to complete a task was 24 s with an accuracy rate of approximately 68%. This study served as a proof of concept to determine if treemaps could be beneficial in assessing surgical data retrospectively by allowing surgeons and healthcare administrators to make quick visual judgments. The study found that factors about the layout design affect judgment performance. Future research is needed to examine whether implementing the treemap within a dashboard system will improve on judgment accuracy for surgical quality questions. Published by Elsevier Inc.

  2. Design of Restoration Method Based on Compressed Sensing and TwIST Algorithm

    NASA Astrophysics Data System (ADS)

    Zhang, Fei; Piao, Yan

    2018-04-01

    In order to improve the subjective and objective quality of degraded images at low sampling rates effectively,save storage space and reduce computational complexity at the same time, this paper proposes a joint restoration algorithm of compressed sensing and two step iterative threshold shrinkage (TwIST). The algorithm applies the TwIST algorithm which used in image restoration to the compressed sensing theory. Then, a small amount of sparse high-frequency information is obtained in frequency domain. The TwIST algorithm based on compressed sensing theory is used to accurately reconstruct the high frequency image. The experimental results show that the proposed algorithm achieves better subjective visual effects and objective quality of degraded images while accurately restoring degraded images.

  3. Slit-lamp photography and videography with high magnifications

    PubMed Central

    Yuan, Jin; Jiang, Hong; Mao, Xinjie; Ke, Bilian; Yan, Wentao; Liu, Che; Cintrón-Colón, Hector R; Perez, Victor L; Wang, Jianhua

    2015-01-01

    Purpose To demonstrate the use of the slit-lamp photography and videography with extremely high magnifications for visualizing structures of the anterior segment of the eye. Methods A Canon 60D digital camera with Movie Crop Function was adapted into a Nikon FS-2 slit-lamp to capture still images and video clips of the structures of the anterior segment of the eye. Images obtained using the slit-lamp were tested for spatial resolution. The cornea of human eyes was imaged with the slit-lamp and the structures were compared with the pictures captured using the ultra-high resolution optical coherence tomography (UHR-OCT). The central thickness of the corneal epithelium and total cornea was obtained using the slit-lamp and the results were compared with the thickness obtained using UHR-OCT. Results High-quality ocular images and higher spatial resolutions were obtained by using the slit-lamp with extremely high magnifications and Movie Crop Function, rather than the traditional slit-lamp. The structures and characteristics of the cornea, such as the normal epithelium, abnormal epithelium of corneal intraepithelial neoplasia, LASIK interface, and contact lenses, were clearly visualized using this device. These features were confirmed by comparing the obtained images with those acquired using UHR-OCT. Moreover, the tear film debris on the ocular surface and the corneal nerve in the anterior corneal stroma were also visualized. The thicknesses of the corneal epithelium and total cornea were similar to that measured using UHR-OCT (P < 0.05). Conclusions We demonstrated that the slit-lamp photography and videography with extremely high magnifications allows better visualization of the anterior segment structures of the eye, especially of the epithelium, when compared with the traditional slit-lamp. PMID:26020484

  4. PSQM-based RR and NR video quality metrics

    NASA Astrophysics Data System (ADS)

    Lu, Zhongkang; Lin, Weisi; Ong, Eeping; Yang, Xiaokang; Yao, Susu

    2003-06-01

    This paper presents a new and general concept, PQSM (Perceptual Quality Significance Map), to be used in measuring the visual distortion. It makes use of the selectivity characteristic of HVS (Human Visual System) that it pays more attention to certain area/regions of visual signal due to one or more of the following factors: salient features in image/video, cues from domain knowledge, and association of other media (e.g., speech or audio). PQSM is an array whose elements represent the relative perceptual-quality significance levels for the corresponding area/regions for images or video. Due to its generality, PQSM can be incorporated into any visual distortion metrics: to improve effectiveness or/and efficiency of perceptual metrics; or even to enhance a PSNR-based metric. A three-stage PQSM estimation method is also proposed in this paper, with an implementation of motion, texture, luminance, skin-color and face mapping. Experimental results show the scheme can improve the performance of current image/video distortion metrics.

  5. Fuels planning: science synthesis and integration; social issues fact sheet 13: Strategies for managing fuels and visual quality

    Treesearch

    Christine Esposito

    2006-01-01

    The public's acceptance of forest management practices, including fuels reduction, is heavily based on how forests look. Fuels managers can improve their chances of success by considering aesthetics when making management decisions. This fact sheet reviews a three-part general strategy for managing fuels and visual quality: planning, implementation, and monitoring...

  6. Pedagogy and Quality in Indian Slum School Settings: A Bernsteinian Analysis of Visual Representations in the Integrated Child Development Service

    ERIC Educational Resources Information Center

    Chawla-Duggan, Rita

    2016-01-01

    This paper focuses upon the micro level of the pre-school classroom, taking the example of the Indian Integrated Child Development Service (ICDS), and the discourse of "child-centred" pedagogy that is often associated with quality pre-schooling. Through an analysis of visual data, semi-structured and film elicitation interviews drawn…

  7. Estimated spectrum adaptive postfilter and the iterative prepost filtering algirighms

    NASA Technical Reports Server (NTRS)

    Linares, Irving (Inventor)

    2004-01-01

    The invention presents The Estimated Spectrum Adaptive Postfilter (ESAP) and the Iterative Prepost Filter (IPF) algorithms. These algorithms model a number of image-adaptive post-filtering and pre-post filtering methods. They are designed to minimize Discrete Cosine Transform (DCT) blocking distortion caused when images are highly compressed with the Joint Photographic Expert Group (JPEG) standard. The ESAP and the IPF techniques of the present invention minimize the mean square error (MSE) to improve the objective and subjective quality of low-bit-rate JPEG gray-scale images while simultaneously enhancing perceptual visual quality with respect to baseline JPEG images.

  8. Observing system simulations using synthetic radiances and atmospheric retrievals derived for the AMSU and HIRS in a mesoscale model. [Advanced Microwave Sounding Unit

    NASA Technical Reports Server (NTRS)

    Diak, George R.; Huang, Hung-Lung; Kim, Dongsoo

    1990-01-01

    The paper addresses the concept of synthetic satellite imagery as a visualization and diagnostic tool for understanding satellite sensors of the future and to detail preliminary results on the quality of soundings from the current sensors. Preliminary results are presented on the quality of soundings from the combination of the High-Resolution Infrared Radiometer Sounder and the Advanced Microwave Sounding Unit. Results are also presented on the first Observing System Simulation Experiment using this data in a mesoscale numerical prediction model.

  9. An optical color image watermarking scheme by using compressive sensing with human visual characteristics in gyrator domain

    NASA Astrophysics Data System (ADS)

    Liansheng, Sui; Bei, Zhou; Zhanmin, Wang; Ailing, Tian

    2017-05-01

    A novel optical color image watermarking scheme considering human visual characteristics is presented in gyrator transform domain. Initially, an appropriate reference image is constructed of significant blocks chosen from the grayscale host image by evaluating visual characteristics such as visual entropy and edge entropy. Three components of the color watermark image are compressed based on compressive sensing, and the corresponding results are combined to form the grayscale watermark. Then, the frequency coefficients of the watermark image are fused into the frequency data of the gyrator-transformed reference image. The fused result is inversely transformed and partitioned, and eventually the watermarked image is obtained by mapping the resultant blocks into their original positions. The scheme can reconstruct the watermark with high perceptual quality and has the enhanced security due to high sensitivity of the secret keys. Importantly, the scheme can be implemented easily under the framework of double random phase encoding with the 4f optical system. To the best of our knowledge, it is the first report on embedding the color watermark into the grayscale host image which will be out of attacker's expectation. Simulation results are given to verify the feasibility and its superior performance in terms of noise and occlusion robustness.

  10. High contrast two-photon imaging of fingermarks

    NASA Astrophysics Data System (ADS)

    Stoltzfus, Caleb R.; Rebane, Aleksander

    2016-04-01

    Optically-acquired fingermarks are widely used as evidence across law enforcement agencies as well as in the courts of law. A common technique for visualizing latent fingermarks on nonporous surfaces consists of cyanoacrylate fuming of the fingerprint material, followed by impregnation with a fluorescent dye, which under ultra violet (UV) illumination makes the fingermarks visible and thus accessible for digital recording. However, there exist critical circumstances, when the image quality is compromised due to high background scattering, high auto-fluorescence of the substrate material, or other detrimental photo-physical and photo-chemical effects such as light-induced damage to the sample. Here we present a novel near-infrared (NIR), two-photon induced fluorescence imaging modality, which significantly enhances the quality of the fingermark images, especially when obtained from highly reflective and/or scattering surfaces, while at the same time reducing photo-damage to sensitive forensic samples.

  11. Processes to Preserve Spice and Herb Quality and Sensory Integrity During Pathogen Inactivation

    PubMed Central

    Moberg, Kayla; Amin, Kemia N.; Wright, Melissa; Newkirk, Jordan J.; Ponder, Monica A.; Acuff, Gary R.; Dickson, James S.

    2017-01-01

    Abstract Selected processing methods, demonstrated to be effective at reducing Salmonella, were assessed to determine if spice and herb quality was affected. Black peppercorn, cumin seed, oregano, and onion powder were irradiated to a target dose of 8 kGy. Two additional processes were examined for whole black peppercorns and cumin seeds: ethylene oxide (EtO) fumigation and vacuum assisted‐steam (82.22 °C, 7.5 psia). Treated and untreated spices/herbs were compared (visual, odor) using sensory similarity testing protocols (α = 0.20; β = 0.05; proportion of discriminators: 20%) to determine if processing altered sensory quality. Analytical assessment of quality (color, water activity, and volatile chemistry) was completed. Irradiation did not alter visual or odor sensory quality of black peppercorn, cumin seed, or oregano but created differences in onion powder, which was lighter (higher L *) and more red (higher a*) in color, and resulted in nearly complete loss of measured volatile compounds. EtO processing did not create detectable odor or appearance differences in black peppercorn; however visual and odor sensory quality differences, supported by changes in color (higher b *; lower L *) and increased concentrations of most volatiles, were detected for cumin seeds. Steam processing of black peppercorn resulted in perceptible odor differences, supported by increased concentration of monoterpene volatiles and loss of all sesquiterpenes; only visual differences were noted for cumin seed. An important step in process validation is the verification that no effect is detectable from a sensory perspective. PMID:28407236

  12. The ventral visual pathway: an expanded neural framework for the processing of object quality.

    PubMed

    Kravitz, Dwight J; Saleem, Kadharbatcha S; Baker, Chris I; Ungerleider, Leslie G; Mishkin, Mortimer

    2013-01-01

    Since the original characterization of the ventral visual pathway, our knowledge of its neuroanatomy, functional properties, and extrinsic targets has grown considerably. Here we synthesize this recent evidence and propose that the ventral pathway is best understood as a recurrent occipitotemporal network containing neural representations of object quality both utilized and constrained by at least six distinct cortical and subcortical systems. Each system serves its own specialized behavioral, cognitive, or affective function, collectively providing the raison d'être for the ventral visual pathway. This expanded framework contrasts with the depiction of the ventral visual pathway as a largely serial staged hierarchy culminating in singular object representations and more parsimoniously incorporates attentional, contextual, and feedback effects. Published by Elsevier Ltd.

  13. Degraded visual environment image/video quality metrics

    NASA Astrophysics Data System (ADS)

    Baumgartner, Dustin D.; Brown, Jeremy B.; Jacobs, Eddie L.; Schachter, Bruce J.

    2014-06-01

    A number of image quality metrics (IQMs) and video quality metrics (VQMs) have been proposed in the literature for evaluating techniques and systems for mitigating degraded visual environments. Some require both pristine and corrupted imagery. Others require patterned target boards in the scene. None of these metrics relates well to the task of landing a helicopter in conditions such as a brownout dust cloud. We have developed and used a variety of IQMs and VQMs related to the pilot's ability to detect hazards in the scene and to maintain situational awareness. Some of these metrics can be made agnostic to sensor type. Not only are the metrics suitable for evaluating algorithm and sensor variation, they are also suitable for choosing the most cost effective solution to improve operating conditions in degraded visual environments.

  14. Quality of life and visual acuity outcomes in the Registry in Glaucoma Outcomes Research study.

    PubMed

    Coleman, Anne L; Lum, Flora C; Gliklich, Richard E; Velentgas, Priscilla; Su, Zhaohui

    2016-01-01

    The RiGOR study evaluated the association of treatment and patient-reported outcomes for open-angle glaucoma patients. The Glaucoma Symptom Scale (National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and visual acuity (VA) were collected as quality of life measures. The proportion of patients with improvement of at least two lines of vision was highest in the incisional surgery group (14.2% compared with 9.9% for laser surgery and 10.9% for additional medication). No clinically relevant differences were seen in benefit for the laser surgery or incisional surgery groups compared with additional medications for the Glaucoma Symptom Scale or NEI-VFQ measures or subscales. Differences in quality of life by race need to be explored in further studies.

  15. Visual Sample Plan Version 7.0 User's Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzke, Brett D.; Newburn, Lisa LN; Hathaway, John E.

    2014-03-01

    User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination.more » The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.« less

  16. An analysis of mathematical connection ability based on student learning style on visualization auditory kinesthetic (VAK) learning model with self-assessment

    NASA Astrophysics Data System (ADS)

    Apipah, S.; Kartono; Isnarto

    2018-03-01

    This research aims to analyze the quality of VAK learning with self-assessment toward the ability of mathematical connection performed by students and to analyze students’ mathematical connection ability based on learning styles in VAK learning model with self-assessment. This research applies mixed method type with concurrent embedded design. The subject of this research consists of VIII grade students from State Junior High School 9 Semarang who apply visual learning style, auditory learning style, and kinesthetic learning style. The data of learning style is collected by using questionnaires, the data of mathematical connection ability is collected by performing tests, and the data of self-assessment is collected by using assessment sheets. The quality of learning is qualitatively valued from planning stage, realization stage, and valuation stage. The result of mathematical connection ability test is analyzed quantitatively by mean test, conducting completeness test, mean differentiation test, and mean proportional differentiation test. The result of the research shows that VAK learning model results in well-qualified learning regarded from qualitative and quantitative sides. Students with visual learning style perform the highest mathematical connection ability, students with kinesthetic learning style perform average mathematical connection ability, and students with auditory learning style perform the lowest mathematical connection ability.

  17. An indoor navigation system for the visually impaired.

    PubMed

    Guerrero, Luis A; Vasquez, Francisco; Ochoa, Sergio F

    2012-01-01

    Navigation in indoor environments is highly challenging for the severely visually impaired, particularly in spaces visited for the first time. Several solutions have been proposed to deal with this challenge. Although some of them have shown to be useful in real scenarios, they involve an important deployment effort or use artifacts that are not natural for blind users. This paper presents an indoor navigation system that was designed taking into consideration usability as the quality requirement to be maximized. This solution enables one to identify the position of a person and calculates the velocity and direction of his movements. Using this information, the system determines the user's trajectory, locates possible obstacles in that route, and offers navigation information to the user. The solution has been evaluated using two experimental scenarios. Although the results are still not enough to provide strong conclusions, they indicate that the system is suitable to guide visually impaired people through an unknown built environment.

  18. WORDGRAPH: Keyword-in-Context Visualization for NETSPEAK's Wildcard Search.

    PubMed

    Riehmann, Patrick; Gruendl, Henning; Potthast, Martin; Trenkmann, Martin; Stein, Benno; Froehlich, Benno

    2012-09-01

    The WORDGRAPH helps writers in visually choosing phrases while writing a text. It checks for the commonness of phrases and allows for the retrieval of alternatives by means of wildcard queries. To support such queries, we implement a scalable retrieval engine, which returns high-quality results within milliseconds using a probabilistic retrieval strategy. The results are displayed as WORDGRAPH visualization or as a textual list. The graphical interface provides an effective means for interactive exploration of search results using filter techniques, query expansion, and navigation. Our observations indicate that, of three investigated retrieval tasks, the textual interface is sufficient for the phrase verification task, wherein both interfaces support context-sensitive word choice, and the WORDGRAPH best supports the exploration of a phrase's context or the underlying corpus. Our user study confirms these observations and shows that WORDGRAPH is generally the preferred interface over the textual result list for queries containing multiple wildcards.

  19. A WebGIS-based system for analyzing and visualizing air quality data for Shanghai Municipality

    NASA Astrophysics Data System (ADS)

    Wang, Manyi; Liu, Chaoshun; Gao, Wei

    2014-10-01

    An online visual analytical system based on Java Web and WebGIS for air quality data for Shanghai Municipality was designed and implemented to quantitatively analyze and qualitatively visualize air quality data. By analyzing the architecture of WebGIS and Java Web, we firstly designed the overall scheme for system architecture, then put forward the software and hardware environment and also determined the main function modules for the system. The visual system was ultimately established with the DIV + CSS layout method combined with JSP, JavaScript, and some other computer programming languages based on the Java programming environment. Moreover, Struts, Spring, and Hibernate frameworks (SSH) were integrated in the system for the purpose of easy maintenance and expansion. To provide mapping service and spatial analysis functions, we selected ArcGIS for Server as the GIS server. We also used Oracle database and ESRI file geodatabase to store spatial data and non-spatial data in order to ensure the data security. In addition, the response data from the Web server are resampled to implement rapid visualization through the browser. The experimental successes indicate that this system can quickly respond to user's requests, and efficiently return the accurate processing results.

  20. Experimental design and analysis of JND test on coded image/video

    NASA Astrophysics Data System (ADS)

    Lin, Joe Yuchieh; Jin, Lina; Hu, Sudeng; Katsavounidis, Ioannis; Li, Zhi; Aaron, Anne; Kuo, C.-C. Jay

    2015-09-01

    The visual Just-Noticeable-Difference (JND) metric is characterized by the detectable minimum amount of two visual stimuli. Conducting the subjective JND test is a labor-intensive task. In this work, we present a novel interactive method in performing the visual JND test on compressed image/video. JND has been used to enhance perceptual visual quality in the context of image/video compression. Given a set of coding parameters, a JND test is designed to determine the distinguishable quality level against a reference image/video, which is called the anchor. The JND metric can be used to save coding bitrates by exploiting the special characteristics of the human visual system. The proposed JND test is conducted using a binary-forced choice, which is often adopted to discriminate the difference in perception in a psychophysical experiment. The assessors are asked to compare coded image/video pairs and determine whether they are of the same quality or not. A bisection procedure is designed to find the JND locations so as to reduce the required number of comparisons over a wide range of bitrates. We will demonstrate the efficiency of the proposed JND test, report experimental results on the image and video JND tests.

  1. Perceived vision-related quality of life and risk of falling among community living elderly people.

    PubMed

    Källstrand-Eriksson, Jeanette; Baigi, Amir; Buer, Nina; Hildingh, Cathrine

    2013-06-01

    Falls and fall injuries among the elderly population are common, since ageing is a risk factor of falling. Today, this is a major problem because the ageing population is increasing. There are predictive factors of falling and visual impairment is one of them. Usually, only visual acuity is considered when measuring visual impairment, and nothing regarding a person's functional visual ability is taken into account. Therefore, the aim of this study was to assess the perceived vision-related quality of life among the community living elderly using the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) and to investigate whether there was any association among vision-related quality of life and falls. There were 212 randomly selected elderly people participating in the study. Our study indicated that the participants had an impaired perceived vision-related health status. General health was the only NEI VFQ-25 variable significantly associated with falls in both men and women. However, among men, near and distance activities, vision-specific social functioning, role difficulties and dependency, color and peripheral vision were related to falls. © 2012 Nordic College of Caring Science.

  2. Developing an Interactive Data Visualization Tool to Assess the Impact of Decision Support on Clinical Operations.

    PubMed

    Huber, Timothy C; Krishnaraj, Arun; Monaghan, Dayna; Gaskin, Cree M

    2018-05-18

    Due to mandates from recent legislation, clinical decision support (CDS) software is being adopted by radiology practices across the country. This software provides imaging study decision support for referring providers at the point of order entry. CDS systems produce a large volume of data, providing opportunities for research and quality improvement. In order to better visualize and analyze trends in this data, an interactive data visualization dashboard was created using a commercially available data visualization platform. Following the integration of a commercially available clinical decision support product into the electronic health record, a dashboard was created using a commercially available data visualization platform (Tableau, Seattle, WA). Data generated by the CDS were exported from the data warehouse, where they were stored, into the platform. This allowed for real-time visualization of the data generated by the decision support software. The creation of the dashboard allowed the output from the CDS platform to be more easily analyzed and facilitated hypothesis generation. Integrating data visualization tools into clinical decision support tools allows for easier data analysis and can streamline research and quality improvement efforts.

  3. Estimating quality weights for EQ-5D health states with the time trade-off method in South Korea.

    PubMed

    Jo, Min-Woo; Yun, Sung-Cheol; Lee, Sang-Il

    2008-12-01

    To estimate quality weights of EQ-5D health states with the time trade-off (TTO) method in the general population of South Korea. A total of 500 respondents valued 42 hypothetical EQ-5D health states using the TTO and visual analog scale. The quality weights for all EQ-5D health states were estimated by a random effects model and compared with those from studies in other countries. Overall estimated quality weights for all EQ-5D health states from this study were highly correlated with those from previous studies, but quality weights of individual states were substantially different from those of their corresponding states in other studies. The Korean value set differed from value sets from other countries. Special caution is needed when a value set from one country is applied to another with a different culture.

  4. Full-reference quality assessment of stereoscopic images by learning binocular receptive field properties.

    PubMed

    Shao, Feng; Li, Kemeng; Lin, Weisi; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2015-10-01

    Quality assessment of 3D images encounters more challenges than its 2D counterparts. Directly applying 2D image quality metrics is not the solution. In this paper, we propose a new full-reference quality assessment for stereoscopic images by learning binocular receptive field properties to be more in line with human visual perception. To be more specific, in the training phase, we learn a multiscale dictionary from the training database, so that the latent structure of images can be represented as a set of basis vectors. In the quality estimation phase, we compute sparse feature similarity index based on the estimated sparse coefficient vectors by considering their phase difference and amplitude difference, and compute global luminance similarity index by considering luminance changes. The final quality score is obtained by incorporating binocular combination based on sparse energy and sparse complexity. Experimental results on five public 3D image quality assessment databases demonstrate that in comparison with the most related existing methods, the devised algorithm achieves high consistency with subjective assessment.

  5. Information theoretical assessment of visual communication with wavelet coding

    NASA Astrophysics Data System (ADS)

    Rahman, Zia-ur

    1995-06-01

    A visual communication channel can be characterized by the efficiency with which it conveys information, and the quality of the images restored from the transmitted data. Efficient data representation requires the use of constraints of the visual communication channel. Our information theoretic analysis combines the design of the wavelet compression algorithm with the design of the visual communication channel. Shannon's communication theory, Wiener's restoration filter, and the critical design factors of image gathering and display are combined to provide metrics for measuring the efficiency of data transmission, and for quantitatively assessing the visual quality of the restored image. These metrics are: a) the mutual information (Eta) between the radiance the radiance field and the restored image, and b) the efficiency of the channel which can be roughly measured by as the ratio (Eta) /H, where H is the average number of bits being used to transmit the data. Huck, et al. (Journal of Visual Communication and Image Representation, Vol. 4, No. 2, 1993) have shown that channels desinged to maximize (Eta) , also maximize. Our assessment provides a framework for designing channels which provide the highest possible visual quality for a given amount of data under the critical design limitations of the image gathering and display devices. Results show that a trade-off exists between the maximum realizable information of the channel and its efficiency: an increase in one leads to a decrease in the other. The final selection of which of these quantities to maximize is, of course, application dependent.

  6. Improving Low-Dose Blood-Brain Barrier Permeability Quantification Using Sparse High-Dose Induced Prior for Patlak Model

    PubMed Central

    Fang, Ruogu; Karlsson, Kolbeinn; Chen, Tsuhan; Sanelli, Pina C.

    2014-01-01

    Blood-brain-barrier permeability (BBBP) measurements extracted from the perfusion computed tomography (PCT) using the Patlak model can be a valuable indicator to predict hemorrhagic transformation in patients with acute stroke. Unfortunately, the standard Patlak model based PCT requires excessive radiation exposure, which raised attention on radiation safety. Minimizing radiation dose is of high value in clinical practice but can degrade the image quality due to the introduced severe noise. The purpose of this work is to construct high quality BBBP maps from low-dose PCT data by using the brain structural similarity between different individuals and the relations between the high- and low-dose maps. The proposed sparse high-dose induced (shd-Patlak) model performs by building a high-dose induced prior for the Patlak model with a set of location adaptive dictionaries, followed by an optimized estimation of BBBP map with the prior regularized Patlak model. Evaluation with the simulated low-dose clinical brain PCT datasets clearly demonstrate that the shd-Patlak model can achieve more significant gains than the standard Patlak model with improved visual quality, higher fidelity to the gold standard and more accurate details for clinical analysis. PMID:24200529

  7. The effect of ice skating on psychological well-being and sleep quality of children with visual or hearing impairment.

    PubMed

    Dursun, Onur Burak; Erhan, Süleyman Erim; Ibiş, Esra Özhan; Esin, Ibrahim Selcuk; Keleş, Sadullah; Şirinkan, Ahmet; Yörük, Özgür; Acar, Ethem; Beyhun, Nazim Ercument

    2015-01-01

    Physical exercise and sports have a key role in preventing physical and psychiatric problems in children. However, children with a disability often experience difficulty participating in physical activity due to a lack of suitable opportunities. Participation in an accessible sport is particularly important for these children, but studies examining which sports are beneficial for which disability groups are rare. In this study, we assessed the effects of ice skating on the psychological well-being, self-concept, and sleep quality of children with hearing or visual impairment. Forty students (20 visually impaired and 20 hearing impaired) aged 8-16 were included in a regular ice skating programme for three months. We examined the sleep quality, self-concept, and behavioural and emotional states of the children before and after participating in the programme. There was a significant improvement in self-concept, behavioural and emotional problems, and sleep quality (p < 0.05 for each) of the children with hearing impairment. Although the sleep quality (p = 0.019) and emotional problem scores (p = 0.000) of the visually impaired children improved; self-concept, peer relations and hyperactivity scores of these children worsened (p < 0.05 for each). Ice skating is one of the popular sport alternatives that gives children the opportunity to exercise and have fun together. The results of this study revealed that regular ice skating programmes may have positive effects on the psychological well-being of children with hearing impairment. Despite some positive effects, caution must be use when including visually impaired children in ice skating programmes. Generalization of the study's outcomes is limited as the study group were residential students enrolled in special education institutions for children who are blind or deaf. Ice skating is a community-based sport and a popular leisure activity that can also have benefits for people with disabilities. Ice skating and children with hearing impairment: Self-concept, behavioural and emotional problems, and sleep quality of the children with hearing impairment significantly improved after ice skating. Ice skating programmes may be considered as a rehabilitation alternative for children with hearing impairment. Ice skating and children with visual impairment: Caution must be use when including children with visual impairment in ice skating programmes because of possible negative psychological outcomes. Balance exercises before starting the practices on ice should be considered for preventing some possible negative outcomes in children with visual impairment.

  8. Sounds of silence: How to animate virtual worlds with sound

    NASA Technical Reports Server (NTRS)

    Astheimer, Peter

    1993-01-01

    Sounds are an integral and sometimes annoying part of our daily life. Virtual worlds which imitate natural environments gain a lot of authenticity from fast, high quality visualization combined with sound effects. Sounds help to increase the degree of immersion for human dwellers in imaginary worlds significantly. The virtual reality toolkit of IGD (Institute for Computer Graphics) features a broad range of standard visual and advanced real-time audio components which interpret an object-oriented definition of the scene. The virtual reality system 'Virtual Design' realized with the toolkit enables the designer of virtual worlds to create a true audiovisual environment. Several examples on video demonstrate the usage of the audio features in Virtual Design.

  9. Hybrid 3D reconstruction and image-based rendering techniques for reality modeling

    NASA Astrophysics Data System (ADS)

    Sequeira, Vitor; Wolfart, Erik; Bovisio, Emanuele; Biotti, Ester; Goncalves, Joao G. M.

    2000-12-01

    This paper presents a component approach that combines in a seamless way the strong features of laser range acquisition with the visual quality of purely photographic approaches. The relevant components of the system are: (i) Panoramic images for distant background scenery where parallax is insignificant; (ii) Photogrammetry for background buildings and (iii) High detailed laser based models for the primary environment, structure of exteriors of buildings and interiors of rooms. These techniques have a wide range of applications in visualization, virtual reality, cost effective as-built analysis of architectural and industrial environments, building facilities management, real-estate, E-commerce, remote inspection of hazardous environments, TV production and many others.

  10. The Prevalence of Age-Related Eye Diseases and Visual Impairment in Aging: Current Estimates

    PubMed Central

    Klein, Ronald; Klein, Barbara E. K.

    2013-01-01

    Purpose. To examine prevalence of five age-related eye conditions (age-related cataract, AMD, open-angle glaucoma, diabetic retinopathy [DR], and visual impairment) in the United States. Methods. Review of published scientific articles and unpublished research findings. Results. Cataract, AMD, open-angle glaucoma, DR, and visual impairment prevalences are high in four different studies of these conditions, especially in people over 75 years of age. There are disparities among racial/ethnic groups with higher age-specific prevalence of DR, open-angle glaucoma, and visual impairment in Hispanics and blacks compared with whites, higher prevalence of age-related cataract in whites compared with blacks, and higher prevalence of late AMD in whites compared with Hispanics and blacks. The estimates are based on old data and do not reflect recent changes in the distribution of age and race/ethnicity in the United States population. There are no epidemiologic estimates of prevalence for many visually-impairing conditions. Conclusions. Ongoing prevalence surveys designed to provide reliable estimates of visual impairment, AMD, age-related cataract, open-angle glaucoma, and DR are needed. It is important to collect objective data on these and other conditions that affect vision and quality of life in order to plan for health care needs and identify areas for further research. PMID:24335069

  11. Lighting design for globally illuminated volume rendering.

    PubMed

    Zhang, Yubo; Ma, Kwan-Liu

    2013-12-01

    With the evolution of graphics hardware, high quality global illumination becomes available for real-time volume rendering. Compared to local illumination, global illumination can produce realistic shading effects which are closer to real world scenes, and has proven useful for enhancing volume data visualization to enable better depth and shape perception. However, setting up optimal lighting could be a nontrivial task for average users. There were lighting design works for volume visualization but they did not consider global light transportation. In this paper, we present a lighting design method for volume visualization employing global illumination. The resulting system takes into account view and transfer-function dependent content of the volume data to automatically generate an optimized three-point lighting environment. Our method fully exploits the back light which is not used by previous volume visualization systems. By also including global shadow and multiple scattering, our lighting system can effectively enhance the depth and shape perception of volumetric features of interest. In addition, we propose an automatic tone mapping operator which recovers visual details from overexposed areas while maintaining sufficient contrast in the dark areas. We show that our method is effective for visualizing volume datasets with complex structures. The structural information is more clearly and correctly presented under the automatically generated light sources.

  12. [Medical Image Registration Method Based on a Semantic Model with Directional Visual Words].

    PubMed

    Jin, Yufei; Ma, Meng; Yang, Xin

    2016-04-01

    Medical image registration is very challenging due to the various imaging modality,image quality,wide inter-patients variability,and intra-patient variability with disease progressing of medical images,with strict requirement for robustness.Inspired by semantic model,especially the recent tremendous progress in computer vision tasks under bag-of-visual-word framework,we set up a novel semantic model to match medical images.Since most of medical images have poor contrast,small dynamic range,and involving only intensities and so on,the traditional visual word models do not perform very well.To benefit from the advantages from the relative works,we proposed a novel visual word model named directional visual words,which performs better on medical images.Then we applied this model to do medical registration.In our experiment,the critical anatomical structures were first manually specified by experts.Then we adopted the directional visual word,the strategy of spatial pyramid searching from coarse to fine,and the k-means algorithm to help us locating the positions of the key structures accurately.Sequentially,we shall register corresponding images by the areas around these positions.The results of the experiments which were performed on real cardiac images showed that our method could achieve high registration accuracy in some specific areas.

  13. Towards A Complete Model Of Photopic Visual Threshold Performance

    NASA Astrophysics Data System (ADS)

    Overington, I.

    1982-02-01

    Based on a wide variety of fragmentary evidence taken from psycho-physics, neurophysiology and electron microscopy, it has been possible to put together a very widely applicable conceptual model of photopic visual threshold performance. Such a model is so complex that a single comprehensive mathematical version is excessively cumbersome. It is, however, possible to set up a suite of related mathematical models, each of limited application but strictly known envelope of usage. Such models may be used for assessment of a variety of facets of visual performance when using display imagery, including effects and interactions of image quality, random and discrete display noise, viewing distance, image motion, etc., both for foveal interrogation tasks and for visual search tasks. The specific model may be selected from the suite according to the assessment task in hand. The paper discusses in some depth the major facets of preperceptual visual processing and their interaction with instrumental image quality and noise. It then highlights the statistical nature of visual performance before going on to consider a number of specific mathematical models of partial visual function. Where appropriate, these are compared with widely popular empirical models of visual function.

  14. Mobile Phone Apps to Improve Medication Adherence: A Systematic Stepwise Process to Identify High-Quality Apps.

    PubMed

    Santo, Karla; Richtering, Sarah S; Chalmers, John; Thiagalingam, Aravinda; Chow, Clara K; Redfern, Julie

    2016-12-02

    There are a growing number of mobile phone apps available to support people in taking their medications and to improve medication adherence. However, little is known about how these apps differ in terms of features, quality, and effectiveness. We aimed to systematically review the medication reminder apps available in the Australian iTunes store and Google Play to assess their features and their quality in order to identify high-quality apps. This review was conducted in a similar manner to a systematic review by using a stepwise approach that included (1) a search strategy; (2) eligibility assessment; (3) app selection process through an initial screening of all retrieved apps and full app review of the included apps; (4) data extraction using a predefined set of features considered important or desirable in medication reminder apps; (5) analysis by classifying the apps as basic and advanced medication reminder apps and scoring and ranking them; and (6) a quality assessment by using the Mobile App Rating Scale (MARS), a reliable tool to assess mobile health apps. We identified 272 medication reminder apps, of which 152 were found only in Google Play, 87 only in iTunes, and 33 in both app stores. Apps found in Google Play had more customer reviews, higher star ratings, and lower cost compared with apps in iTunes. Only 109 apps were available for free and 124 were recently updated in 2015 or 2016. Overall, the median number of features per app was 3.0 (interquartile range 4.0) and only 18 apps had ≥9 of the 17 desirable features. The most common features were flexible scheduling that was present in 56.3% (153/272) of the included apps, medication tracking history in 54.8% (149/272), snooze option in 34.9% (95/272), and visual aids in 32.4% (88/272). We classified 54.8% (149/272) of the included apps as advanced medication reminder apps and 45.2% (123/272) as basic medication reminder apps. The advanced apps had a higher number of features per app compared with the basic apps. Using the MARS instrument, we were able to identify high-quality apps that were rated as being very interesting and entertaining, highly interactive and customizable, intuitive, and easy to use and to navigate as well as having a high level of visual appeal and good-quality information. Many medication reminder apps are available in the app stores; however, the majority of them did not have many of the desirable features and were, therefore, considered low quality. Through a systematic stepwise process, we were able to identify high-quality apps to be tested in a future study that will provide evidence on the use of medication reminder apps to improve medication adherence. ©Karla Santo, Sarah S Richtering, John Chalmers, Aravinda Thiagalingam, Clara K Chow, Julie Redfern. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 02.12.2016.

  15. Mobile Phone Apps to Improve Medication Adherence: A Systematic Stepwise Process to Identify High-Quality Apps

    PubMed Central

    Richtering, Sarah S; Chalmers, John; Thiagalingam, Aravinda; Chow, Clara K; Redfern, Julie

    2016-01-01

    Background There are a growing number of mobile phone apps available to support people in taking their medications and to improve medication adherence. However, little is known about how these apps differ in terms of features, quality, and effectiveness. Objective We aimed to systematically review the medication reminder apps available in the Australian iTunes store and Google Play to assess their features and their quality in order to identify high-quality apps. Methods This review was conducted in a similar manner to a systematic review by using a stepwise approach that included (1) a search strategy; (2) eligibility assessment; (3) app selection process through an initial screening of all retrieved apps and full app review of the included apps; (4) data extraction using a predefined set of features considered important or desirable in medication reminder apps; (5) analysis by classifying the apps as basic and advanced medication reminder apps and scoring and ranking them; and (6) a quality assessment by using the Mobile App Rating Scale (MARS), a reliable tool to assess mobile health apps. Results We identified 272 medication reminder apps, of which 152 were found only in Google Play, 87 only in iTunes, and 33 in both app stores. Apps found in Google Play had more customer reviews, higher star ratings, and lower cost compared with apps in iTunes. Only 109 apps were available for free and 124 were recently updated in 2015 or 2016. Overall, the median number of features per app was 3.0 (interquartile range 4.0) and only 18 apps had ≥9 of the 17 desirable features. The most common features were flexible scheduling that was present in 56.3% (153/272) of the included apps, medication tracking history in 54.8% (149/272), snooze option in 34.9% (95/272), and visual aids in 32.4% (88/272). We classified 54.8% (149/272) of the included apps as advanced medication reminder apps and 45.2% (123/272) as basic medication reminder apps. The advanced apps had a higher number of features per app compared with the basic apps. Using the MARS instrument, we were able to identify high-quality apps that were rated as being very interesting and entertaining, highly interactive and customizable, intuitive, and easy to use and to navigate as well as having a high level of visual appeal and good-quality information. Conclusions Many medication reminder apps are available in the app stores; however, the majority of them did not have many of the desirable features and were, therefore, considered low quality. Through a systematic stepwise process, we were able to identify high-quality apps to be tested in a future study that will provide evidence on the use of medication reminder apps to improve medication adherence. PMID:27913373

  16. Recursive search method for the image elements of functionally defined surfaces

    NASA Astrophysics Data System (ADS)

    Vyatkin, S. I.

    2017-05-01

    This paper touches upon the synthesis of high-quality images in real time and the technique for specifying three-dimensional objects on the basis of perturbation functions. The recursive search method for the image elements of functionally defined objects with the use of graphics processing units is proposed. The advantages of such an approach over the frame-buffer visualization method are shown.

  17. Prevalence and Causes of Visual Impairment and Blindness among Cocoa Farmers in Ghana.

    PubMed

    Boadi-Kusi, Samuel Bert; Hansraj, Rekha; Mashige, Khathutshelo Percy; Osafo-Kwaako, Alfred; Ilechie, Alex Azuka; Abokyi, Samuel

    2017-02-01

    To determine the prevalence and causes of visual impairment and blindness among cocoa farmers in Ghana in order to formulate early intervention strategies. A cross-sectional study using multistage random sampling from four cocoa growing districts in Ghana was conducted from November 2013 to April 2014. A total of 512 cocoa farmers aged 40 years and older were interviewed and examined. The brief interview questionnaire was administered to elicit information on the demographics and socioeconomic details of participants. The examination included assessment of visual acuity (VA), retinoscopy, subjective refraction, direct ophthalmoscopy, slit-lamp biomicroscopy and intraocular pressure (IOP). For quality assurance, a random sample of cocoa farmers were selected and re-examined independently. Moderate to severe visual impairment (VA <6/18 to 3/60 in the better-seeing eye) was present in 89 participants (17.4%) and 27 (5.3%) were blind (presenting VA <3/60 in the better eye) defined using presenting VA. The main causes of visual impairment were cataract (45, 38.8%), uncorrected refractive error (42, 36.2%), posterior segment disorders (15, 12.9%), and corneal opacity (11, 9.5%). The prevalence of visual impairment and blindness among cocoa farmers in Ghana is relatively high. The major causes of visual impairment and blindness are largely preventable or treatable, indicating the need for early eye care service interventions.

  18. Single-kernel analysis of fumonisins and other fungal metabolites in maize from South African subsistence farmers.

    PubMed

    Mogensen, J M; Sørensen, S M; Sulyok, M; van der Westhuizen, L; Shephard, G S; Frisvad, J C; Thrane, U; Krska, R; Nielsen, K F

    2011-12-01

    Fumonisins are important Fusarium mycotoxins mainly found in maize and derived products. This study analysed maize from five subsistence farmers in the former Transkei region of South Africa. Farmers had sorted kernels into good and mouldy quality. A total of 400 kernels from 10 batches were analysed; of these 100 were visually characterised as uninfected and 300 as infected. Of the 400 kernels, 15% were contaminated with 1.84-1428 mg kg(-1) fumonisins, and 4% (n=15) had a fumonisin content above 100 mg kg(-1). None of the visually uninfected maize had detectable amounts of fumonisins. The total fumonisin concentration was 0.28-1.1 mg kg(-1) for good-quality batches and 0.03-6.2 mg kg(-1) for mouldy-quality batches. The high fumonisin content in the batches was apparently caused by a small number (4%) of highly contaminated kernels, and removal of these reduced the average fumonisin content by 71%. Of the 400 kernels, 80 were screened for 186 microbial metabolites by liquid chromatography-tandem mass spectrometry, detecting 17 other fungal metabolites, including fusaric acid, equisetin, fusaproliferin, beauvericin, cyclosporins, agroclavine, chanoclavine, rugulosin and emodin. Fusaric acid in samples without fumonisins indicated the possibility of using non-toxinogenic Fusaria as biocontrol agents to reduce fumonisin exposure, as done for Aspergillus flavus. This is the first report of mycotoxin profiling in single naturally infected maize kernels. © 2011 Taylor & Francis

  19. Creating a Framework for Holistic Assessment of Aesthetics: A Response to Nilsson and Axelsson (2015) on Attributes of Aesthetic Quality of Textile Quality1.

    PubMed

    Carbon, Claus-Christian

    2016-02-01

    Nilsson and Axelsson (2015) made an important contribution by linking recent scientific approaches from the field of empirical aesthetics with everyday demands of museum conservators of deciding which items to be preserved or not. The authors made an important effort in identifying the valuable candidates of variables - but focused on visual properties only and on quite high-expertise aspects of aesthetic quality based on very sophisticated evaluations. The present article responds to the target paper by developing the outline of a more holistic approach for future research as a kind of framework that should assist a multi-modal approach, mainly including tactile sense. © The Author(s) 2016.

  20. Model My Watershed: A high-performance cloud application for public engagement, watershed modeling and conservation decision support

    NASA Astrophysics Data System (ADS)

    Aufdenkampe, A. K.; Tarboton, D. G.; Horsburgh, J. S.; Mayorga, E.; McFarland, M.; Robbins, A.; Haag, S.; Shokoufandeh, A.; Evans, B. M.; Arscott, D. B.

    2017-12-01

    The Model My Watershed Web app (https://app.wikiwatershed.org/) and the BiG-CZ Data Portal (http://portal.bigcz.org/) and are web applications that share a common codebase and a common goal to deliver high-performance discovery, visualization and analysis of geospatial data in an intuitive user interface in web browser. Model My Watershed (MMW) was designed as a decision support system for watershed conservation implementation. BiG CZ Data Portal was designed to provide context and background data for research sites. Users begin by creating an Area of Interest, via an automated watershed delineation tool, a free draw tool, selection of a predefined area such as a county or USGS Hydrological Unit (HUC), or uploading a custom polygon. Both Web apps visualize and provide summary statistics of land use, soil groups, streams, climate and other geospatial information. MMW then allows users to run a watershed model to simulate different scenarios of human impacts on stormwater runoff and water-quality. BiG CZ Data Portal allows users to search for scientific and monitoring data within the Area of Interest, which also serves as a prototype for the upcoming Monitor My Watershed web app. Both systems integrate with CUAHSI cyberinfrastructure, including visualizing observational data from CUAHSI Water Data Center and storing user data via CUAHSI HydroShare. Both systems also integrate with the new EnviroDIY Water Quality Data Portal (http://data.envirodiy.org/), a system for crowd-sourcing environmental monitoring data using open-source sensor stations (http://envirodiy.org/mayfly/) and based on the Observations Data Model v2.

Top